Sample records for efectos del implante

  1. Impacto del Seguro Popular en el gasto catastrófico y de bolsillo en el México rural y urbano, 2005–2008

    PubMed Central

    Sosa-Rubí, Sandra G; Salinas-Rodríguez, Aarón; Galárraga, Omar

    2016-01-01

    Objetivo Estimar el efecto del Seguro Popular (SP) sobre la incidencia del gasto catastrófico en salud (GCS) y sobre el gasto de bolsillo en salud (GBS) en el mediano plazo. Material y métodos Con base en la Encuesta de Evaluación del Seguro Popular (2005–2008), se analizaron los resultados del efecto del SP en la cohorte rural para dos años de seguimiento (2006 y 2008) y en la cohorte urbana para un año (2008). Resultados A nivel conglomerado no se detectaron efectos del SP. A nivel hogar se encontró que el SP tiene un efecto protector en el GCS y en el GBS en consulta externa y hospitalización en zonas rurales; y efectos significativos en la reducción de GBS en consulta externa en zonas urbanas. Conclusiones El SP se muestra como un programa efectivo para proteger a los hogares contra gastos de bolsillo por motivos de salud en el mediano plazo. PMID:22282205

  2. Efectos combinados de la ampliación de la atención primaria de salud y de las transferencias condicionadas de dinero en efectivo sobre la mortalidad infantil en Brasil, 1998–2010*

    PubMed Central

    Guanais, Frederico C.

    2015-01-01

    Objetivos. Examiné los efectos combinados del acceso a la atención primaria mediante el Programa de Salud Familiar (PSF) y las transferencias condicionadas de dinero en efectivo del Programa Bolsa Familia (PBF) sobre la mortalidad infantil posneonatal (MIPN) en Brasil. Métodos. Empleé un análisis ecológico longitudinal usando datos en panel de 4 583 municipios brasileños de 1998 al 2010, con 54 253 observaciones en total. Estimé modelos de regresión de efectos fijos por mínimos cuadrados ordinarios, con la tasa de MIPN como la variable dependiente y el PSF, el PBF y sus interacciones como las principales variables independientes de interés. Resultados. La asociación de una mayor cobertura del PSF con una menor tasa de MIPN se volvió más fuerte conforme aumentaba la cobertura del PBF. En los promedios de todas las demás variables, cuando la cobertura de PBF era 25%, la MIPN predicha fue 5,24 (intervalo de confianza [IC] de 95% = 4,95, 5,53) para una cobertura del PSF de 0%, y de 3,54 (IC de 95% = 2,77, 4,31) para una cobertura del PSF de 100%. Cuando la cobertura del PBF era de 60%, la MIPN predicha fue 4,65 (IC de 95% = 4,36, 4,94) para una cobertura del PSF de 0%, y de 1,38 (IC de 95% = 0,88, 1,89) para una cobertura del PSF de 100%. Conclusiones. El efecto del PSF depende de la ampliación del PBF. Para las poblaciones empobrecidas y subatendidas, la combinación de intervenciones tanto del lado de la oferta como del lado de la demanda podría ser necesaria para mejorar los resultados en salud.

  3. Quantifying Loss of Acoustic Communication Space for Right Whales in and around a U.S. National Marine Sanctuary

    DTIC Science & Technology

    2012-01-01

    buscan mejorar el manejo de los efectos acumulativos del ruido sobre especies marinas y sus hábitats. Palabras Clave: área marina protegida, especies...dependientes del sonido para comunicarse están poco entendidos. Buscamos desarrollar métodos para cuantificar los efectos del enmascaramiento de la comu... tiempo ( tiempo pico de alimentación). Utilizamos un conjunto de grabadoras acústicas autónomas, temporales, montadas en el fondo en el Santuario

  4. [Not Available].

    PubMed

    Cruz-Sáez, María Soledad; Pascual Jimeno, Aitziber; Wlodarczyk, Anna; Polo-López, Rocío; Echeburúa Odriozola, Enrique

    2016-07-19

    Introducción: los problemas relacionados con el peso constituyen un problema importante de salud pública debido a su alta prevalencia y a las adversas consecuencias que tienen para la salud.Objetivo: el objetivo principal de este estudio fue analizar si la depresión y la ansiedad tienen un papel mediador en la relación entre la insatisfacción corporal y las conductas de control del peso en chicas adolescentes con sobrepeso.Material y métodos: en el estudio participaron 140 mujeres de 16 a 20 años con sobrepeso. Las participantes tuvieron que cumplimentar la escala de insatisfacción corporal del EDI-2, las escalas de ansiedad y depresión del GHQ-28 y una adaptación de las escalas del EAT survey para evaluar las conductas de control del peso. Para los análisis estadísticos se utilizaron métodos de diferencias de medias, correlaciones y de mediación secuencial.Resultados: las adolescentes con sobrepeso y alta insatisfacción corporal presentaban más sintomatología ansiosa y depresiva, así como mayor cantidad de conductas de control del peso. Los resultados del análisis de mediación secuencial evidencian que el efecto de la insatisfacción corporal en las conductas de control del peso está parcialmente mediado por las variables depresión y ansiedad. Mientras que la sintomatología ansiosa presenta efectos directos e indirectos sobre las conductas de control de peso, la sintomatología depresiva solamente presenta un efecto indirecto.Conclusiones:los resultados del estudio destacan el rol mediador de la sintomatología depresiva y, especialmente, de la ansiedad en el desarrollo de conductas no saludables de control del peso.

  5. Estudio de los Efectos Gravitomagnéticos en Cuerpos Masivos Rotantes

    NASA Astrophysics Data System (ADS)

    Velandia Heredia, N.; Tejeiro, J. M.

    2008-03-01

    A partir del estudio de los Efectos Gravitomagnéticos en cuerpos masivos rotantes, planteamos la expresión para medir el desfase en el tiempo, para diferentes observadores, que se dan cuando viajan dos rayos de luz por una guía de onda o de manera libre (geodésicas), en el plano azimutal y en el plano polar. Con lo anterior queremos abordar el experimento tipo Michelson y Morley, de forma que podamos involucrar el valor de la densidad del momento angular (a) en el retraso temporal para los dos haces de luz que viajan por los brazos del interferómetro, cuando este último es ubicado en el plano ecuatorial.

  6. PubMed

    López Gómez, Juan José; Pérez Castrillón, José Luis; Romero Bobillo, Enrique; De Luis Román, Daniel A

    2016-11-29

    La obesidad interfiere con el metabolismo óseo a través de factores mecánicos, hormonales e inflamatorios. El principal tratamiento de dicha enfermedad es la dieta, modificación de la cantidad y tipo de alimento. Este tratamiento nutricional tiene una influencia sobre el metabolismo óseo en dos sentidos: modifica el efecto del sobrepeso y la obesidad sobre el hueso e interviene directamente en el turnoveróseo a través de las características de los nutrientes utilizados. Esta revisión analiza la evidencia del efecto sobre el hueso del descenso de peso y del patrón dietético utilizado. Por otra parte, se valorarán las modificaciones que se pueden realizar en la dieta indicada en un paciente obeso para prevenir la pérdida ósea, a corto y largo plazo, y disminuir el riesgo de fractura.

  7. La Observación Sistemática de Vecindarios: El caso de Chile y sus perspectivas para Trabajo Social

    PubMed Central

    Sanhueza, Guillermo E.; Delva, Jorge; Andrade, Fernando H.; Grogan-Kaylor, Andrew; Bares, Cristina; Castillo, Marcela

    2012-01-01

    El estudio acerca de las características de los vecindarios y sus efectos sobre las personas ha llegado a ser un área de creciente atención por parte de investigadores de diversas disciplinas en países desarrollados. Aunque actualmente existen diversas metodologías para estudiar efectos del vecindario, una de las más utilizadas es la Observación Sistemática de Vecindarios –Systematic Social Observation SSO, en inglés—porque permite recolectar información acerca de diversas características del entorno físico, social, ambiental y económico de los vecindarios donde se aplica. El objetivo de este artículo es (i) dar a conocer sumariamente algunas investigaciones influyentes sobre efectos del vecindario en Estados Unidos, ii) describir cómo se diseñó e implementó la Observación Sistemática de Vecindarios en la ciudad de Santiago de Chile, iii) señalar algunos facilitadores y obstaculizadores de la implementación del proyecto y, finalmente iv) enunciar posibles contribuciones y limitaciones que esta metodología ofrecería al trabajo social en Chile. PMID:24791060

  8. Extensión del Formalismo de Orbitales de Defecto Cuántico al tratamiento del efecto Stark (SQDO).

    NASA Astrophysics Data System (ADS)

    Menéndez, J. M.; Martín, I.; Velasco, A. M.

    El estudio experimental de las interacciones de átomos Rydberg altamente excitados con campos eléctricos ha experimentado un creciente interés durante las dos últimas décadas debido, en gran medida, al desarrollo de nuevas técnicas para crear y estudiar átomos Rydberg en el laboratorio. Acompañando a estas nuevas técnicas experimentales, es necesario el desarrollo de modelos teóricos que nos permitan contrastar sus medidas y conocer mejor los fundamentos de los mismos. Desde el punto de vista teórico el conocimiento del desdoblamiento de los niveles energéticos de un átomo en función de la magnitud del campo eléctrico aplicado (lo que se conoce como mapa Stark) es el mejor punto de partida para la descripción del sistema y un prerrequisito fundamental para el cálculo de distintas propiedades atómicas en presencia del campo eléctrico tales como intensidades de transición, umbrales de ionización de campo eléctrico, tiempos de vida, posición y anchura de cruces evitados, etc. En este trabajo presentamos la adaptación del método de orbitales de defecto cuántico [1,2,3] al tratamiento del efecto Stark (SQDO) [4] y su aplicación al cálculo de los desdoblamientos energéticos y fuerzas de oscilador de estados Rydberg en los átomos de Li, Na y K. El propósito de este estudio es, por un lado, desarrollar métodos fiables para la determinación de propiedades atómicas en presencia de campos eléctricos y, por otro, mostrar la fiabilidad de las funciones de onda QDO en la descripción del efecto Stark en sistemas atómicos.

  9. Accelerating Adaptation of Natural Resource Management to Address Climate Change

    PubMed Central

    Cross, Molly S; McCarthy, Patrick D; Garfin, Gregg; Gori, David; Enquist, Carolyn AF

    2013-01-01

    Abstract Natural resource managers are seeking tools to help them address current and future effects of climate change. We present a model for collaborative planning aimed at identifying ways to adapt management actions to address the effects of climate change in landscapes that cross public and private jurisdictional boundaries. The Southwest Climate Change Initiative (SWCCI) piloted the Adaptation for Conservation Targets (ACT) planning approach at workshops in 4 southwestern U.S. landscapes. This planning approach successfully increased participants’ self-reported capacity to address climate change by providing them with a better understanding of potential effects and guiding the identification of solutions. The workshops fostered cross-jurisdictional and multidisciplinary dialogue on climate change through active participation of scientists and managers in assessing climate change effects, discussing the implications of those effects for determining management goals and activities, and cultivating opportunities for regional coordination on adaptation of management plans. Facilitated application of the ACT framework advanced group discussions beyond assessing effects to devising options to mitigate the effects of climate change on specific species, ecological functions, and ecosystems. Participants addressed uncertainty about future conditions by considering more than one climate-change scenario. They outlined opportunities and identified next steps for implementing several actions, and local partnerships have begun implementing actions and conducting additional planning. Continued investment in adaptation of management plans and actions to address the effects of climate change in the southwestern United States and extension of the approaches used in this project to additional landscapes are needed if biological diversity and ecosystem services are to be maintained in a rapidly changing world. Acelerando la Adaptación del Manejo de Recursos Naturales para Atender el Cambio Climático Resumen Los manejadores de recursos naturales están buscando herramientas para ayudarles a atender los efectos actuales y futuros del cambio climático. Presentamos un modelo para la planificación colaborativa enfocada a identificar formas para adaptar las acciones de manejo para atender los efectos del cambio climático en paisajes que cruzan límites jurisdiccionales públicos y privados. La Iniciativa Sudoccidental de Cambio Climático (ISCC) puso a prueba el método de planificación de Adaptación para Metas de Conservación (AMC) en talleres en cuatro paisajes del suroeste de E. U. A. Este método de planificación incrementó exitosamente la capacidad de los participantes para atender el cambio climático al proporcionarles un mejor entendimiento de los efectos potenciales y guiar la identificación de soluciones. Los talleres promovieron el diálogo trans-jurisdiccional y multidisciplinario sobre cambio climático mediante la participación activa de científicos y manejadores en la evaluación de efectos del cambio climático, la discusión de implicaciones de esos efectos para determinar las metas y actividades de manejo y desarrollar oportunidades para la coordinación regional de la adaptación de planes de manejo. La aplicación simplificada del marco AMC llevó las discusiones de grupo más allá de la evaluación de los efectos a la concepción de opciones para mitigar los efectos del cambio climático sobres determinadas especies, funciones ecológicas y ecosistemas. Los participantes abordaron la incertidumbre de las condiciones futuras al considerar más de un escenario de cambio climático. Delinearon oportunidades e identificaron los siguientes pasos para la implementación de varias acciones, y asociaciones locales han comenzado a implementar acciones y realizar planificación adicional. Se requiere inversión continua en la adaptación de planes y acciones de manejo para atender los efectos del cambio climático en el suroeste de Estados Unidos y la extensión de los métodos utilizados en este proyecto en paisajes adicionales si se quiere mantener la diversidad biológica y los servicios de los ecosistemas en un mundo que cambia rápidamente. PMID:23110636

  10. EL MANEJO DE LA BIODIVERSIDAD EN EL SIGLO XXI

    Treesearch

    ARIEL E. LUGO

    2001-01-01

    ser humano está transformando rápidamente el planeta Tierra (Meyer y Turner, 1994; Vitousek et al., 1997a). Su actividad tiene efectos globales que modifican el ambiente terrícola (Tabla I). Estos cambios, que comenzaron con la revolución industrial del siglo XIX, serán más notables en el siglo XXI en lo que se ha denominado la era Homogeocena donde el efecto dominante...

  11. Contribución al flujo infrarrojo de las estrellas Be de la recombinación dielectrónica del MgII

    NASA Astrophysics Data System (ADS)

    Cruzado, A.; di Rocco, H.; Ringuelet, A.

    Para evaluar la contribución del proceso de recombinación dielectrónica del átomo de MgII al exceso de flujo infrarrojo observado en las estrellas Be, calculamos la energía emitida en las líneas originadas por este proceso. Se evaluaron los efectos de las condiciones físicas del medio, como la temperatura electrónica y la densidad electrónica, sobre el flujo emitido. Se consideró también la influencia de una posible opacidad.

  12. Modelizacion, control e implementacion de un procesador energetico paralelo para aplicacion en sistemas multisalida

    NASA Astrophysics Data System (ADS)

    Ferreres Sabater, Agustin

    Cualquier sistema electronico que incluya un procesado o tratamiento de la senal, y ademas, algun tipo de actuador mecanico generalmente necesita, como minimo, dos tensiones diferentes de alimentacion. Excluyendo los sistemas de alimentacion distribuida, la solucion tecnica mas utilizada para proporcionar dos o mas tensiones consiste en las fuentes de alimentacion multisalida. En una fuente de alimentacion multisalida los diferentes circuitos que conforman cada salida comparten un mismo transformador de potencia optimizando coste, masa, y volumen. Las ventajas obtenidas con este procedimiento tienen en su contra el efecto que sobre cada salida individual provocan las demas en su conjunto debido, principalmente, a los efectos de los elementos parasitos de los componentes. Un cambio de carga en una de las salidas produce un transitorio que es visto por todas las demas como un efecto de impedancia cruzada, y al final del transitorio, la tension de cada salida es diferente respecto a la que tenian antes del transitorio. Este ultimo resultado se conoce como regulacion cruzada. La disminucion de los efectos de la regulacion cruzada ha sido objeto de estudio durante los ultimos anos. El objetivo ha sido el desarrollo de distintas estrategias que permiten, desde disminuir los efectos de la regulacion cruzada hasta los niveles deseables, a eliminarla completamente. El resultado final suele suponer una penalizacion sobre el diseno del sistema directamente proporcional al grado de regulacion a conseguir en las distintas salidas. Entre las soluciones propuestas para eliminar la regulacion cruzada las tecnicas de post-regulacion se han consolidado como la opcion mas aceptada ya que, pueden aplicarse a cualquier convertidor y no suponen ninguna complejidad adicional a la hora de plantear el diseno. En esta Tesis Doctoral se abordara el estudio de la tecnica conocida como postregulacion mediante transformador controlado, que si bien se ha empleado en convertidores resonantes, su modelizacion, y aplicacion en convertidores PWM, esta aun por estudiar y valorar. El primer Capitulo consiste en una breve introduccion al problema de la regulacion cruzada y la impedancia cruzada para posteriormente describir las tecnicas de post-regulacion actualmente mas empleadas, con especial atencion al post-regulador con transformador controlado. El Capitulo segundo trata del estudio de las caracteristicas estaticas del postregulador con transformador controlado. Partiendo de los estudios disponibles sobre el postregulador se plantean mejoras en su modo de actuacion y se discuten tres alternativas diferentes para controlar el transformador. Las dos primeras consisten en emplear un convertidor auxiliar Boost en sus dos modos de funcionamiento, continuo y discontinuo. La tercera consiste en controlar el transformador con una tension PWM directamente, sin filtrado. Finalmente se comprueba experimentalmente, para el estado estacionario, el funcionamiento del post-regulador para cada uno de los tres metodos de control. El Capitulo tercero trata de la dinamica de la salida controlada con el post-regulador cuando este emplea un convertidor auxiliar tipo Boost. Mediante la tecnica de promediado de variables de estado se propone el modelo de pequena senal, tanto para el modo continuo como para el modo discontinuo de funcionamiento del convertidor auxiliar. Los resultados mas significativos de esta seccion son las expresiones analiticas de las impedancias cruzadas y de la impedancia de la salida post-regulada. Como complemento al modelo de pequena senal se plantea un modelo de gran senal implementado sobre el simulador Pspice. Con este nuevo modelo se reproducen los resultados obtenidos con el modelo de pequena senal y ademas es posible simular los transitorios en las tensiones de salida ante cambios de carga. La modelizacion del convertidor cuando el transformador se controla con una tension PWM sin filtrar es el objetivo del Capitulo 4. En las secciones siguientes del Capitulo se plantea el correspondiente modelo de gran senal aplicado a un nuevo prototipo experimental, de mayor tension de entrada y mayores corrientes de salida. El final del Capitulo contrasta los resultados experimentales con los teoricos confirmando la utilidad del modelo de gran senal como una herramienta basica de diseno. Finalmente, en el Capitulo 5, se presentan las conclusiones y la valoracion de los diferentes estudios plateados a lo largo de la Tesis Doctoral.

  13. Proyecto para la medición sistemática de seeing en CASLEO

    NASA Astrophysics Data System (ADS)

    Fernández Lajus, E.; Forte, J. C.

    La calidad del seeing astronómico es ciertamente uno de los parámetros mas importantes que caracterizan el sitio de un observatorio. Por tanto se desea determinar si el alto valor de seeing observado con el telescopio de 2.15 m se debe a efectos internos y/o del entorno a la cupula o si se debe simplemente al seeing propio del lugar. El actual mecanismo de refrigeración del espejo primario del 2.15, parece haber mejorado notablemente la calidad del seeing. Sin embargo se hace necesario saber hasta que punto el valor del seeing puede ser mejorado. La primera etapa del proyecto consistió en la puesta a punto del telescopio emplazado para este propósito y la adquisición de las primeras medidas tentativas de seeing.

  14. CONTAMINACIÓN AMBIENTAL, VARIABILIDAD CLIMÁTICA Y CAMBIO CLIMÁTICO: UNA REVISIÓN DEL IMPACTO EN LA SALUD DE LA POBLACIÓN PERUANA

    PubMed Central

    Gonzales, Gustavo F.; Zevallos, Alisson; Gonzales-Castañeda, Cynthia; Nuñez, Denisse; Gastañaga, Carmen; Cabezas, César; Naeher, Luke; Levy, Karen; Steenland, Kyle

    2015-01-01

    RESUMEN El presente artículo es una revisión sobre la contaminación del agua, el aire y el efecto del cambio climático en la salud de la población peruana. Uno de los principales contaminantes del aire es el material particulado menor de 2,5 μ (PM 2,5), en la ciudad de Lima, anualmente 2300 muertes prematuras son atribuibles a este contaminante. Otro problema es la contaminación del aire domiciliario por el uso de cocinas con combustible de biomasa, donde la exposición excesiva a PM 2,5 dentro de las casas es responsable de aproximadamente 3000 muertes prematuras anuales entre adultos, con otro número desconocido de muertes entre niños debido a infecciones respiratorias. La contaminación del agua tiene como principales causas los desagües vertidos directamente a los ríos, minerales (arsénico) de varias fuentes, y fallas de las plantas de tratamiento. En el Perú, el cambio climático puede impactar en la frecuencia y severidad del fenómeno de El Niño oscilación del sur (ENSO) que se ha asociado con un incremento en los casos de enfermedades como cólera, malaria y dengue. El cambio climático incrementa la temperatura y puede extender las áreas afectadas por enfermedades transmitidas por vectores, además de tener efecto en la disponibilidad del agua y en la contaminación del aire. En conclusión, el Perú, pasa por una transición de factores de riesgo ambientales, donde coexisten riesgos tradicionales y modernos, y persisten los problemas infecciosos y crónicos, algunos de los cuales se asocian con problemas de contaminación de agua y de aire. PMID:25418656

  15. Estimaciones de cambio climatico para Michoacan: Implicaciones para el sector agropecuario y forestal y para la conservacion de la Mariposa Monarca [In Spanish

    Treesearch

    Cuauhtemoc Saenz-Romero; Gerald E. Rehfeldt; Nicholas L. Crookston; Pierre Duval; Jean Beaulieu

    2009-01-01

    El cambio climatico, conocido comunmente como calentamiento global, es el incremento de la temperatura a nivel mundial y los cambios que de ello derivan, causados por el "efecto invernadero" del bioxido de carbono (CO2) y otros gases emitidos a la atmosfera. El uso de combustibles fosiles (carbon y derivados del petroleo, como gasolina, diesel, combustoleo y...

  16. La utilizacion de los mapas conceptuales en la ensenanza de biologia y su efecto sobre el dominio del proceso de fotosintesis en los estudiantes universitarios

    NASA Astrophysics Data System (ADS)

    Gonzalez Rivera, Maria M.

    Se investigo el efecto de los mapas conceptuales sobre el dominio del proceso de fotosintesis en estudiantes universitarios. La investigacion utilizo dos estrategias: mapas conceptuales individuales y mapas conceptuales colaborativos, con el fin de investigar si existen diferencias significativas en el dominio del proceso de fotosintesis. El analisis de los datos incluyo aspectos cualitativos y cuantitativos. Se desprende del estudio que el 80% de los estudiantes describen la utilizacion de los mapas conceptuales como una experiencia beneficiosa. El 70% de los estudiantes expreso que los mapas conceptuales son utiles en el aprendizaje del proceso de fotosintesis y el 61% indico que facilitan la comprension de los conceptos. Los hallazgos mas importantes del analisis cuantitativo indican que los estudiantes que utilizaron los mapas conceptuales mejoraron significativamente su desempeno en la posprueba global. Se utilizo la prueba Mann-Whitney para investigar si existian diferencias significativas en la posprueba y preprueba global, el valor de W = 1945.0, para un valor p de 0.00, lo cual establece diferencias significativas. Para determinar si existian diferencias significativas entre la posprueba y preprueba del grupo individual, se realizo la prueba nuevamente. El valor de W correspondio a 490.5, que es significativo, con un valor p de 0.00. Se concluye que existen diferencias significativas entre la ejecucion de la posprueba y preprueba del grupo individual. Los datos proveen suficiente evidencia para sostener que los estudiantes que utilizaron la estrategia de mapas conceptuales individuales mejoraron el dominio del proceso de fotosintesis significativamente. Se realizo nuevamente la prueba para los resultados de posprueba y preprueba del grupo colaborativo. El valor de W correspondio a 446 con un valor p de 0.00. Se concluyo que existen diferencias significativas entre la ejecucion de la posprueba y preprueba del grupo colaborativo. Finalmente, se efectuo una prueba Mann-Whitney comparando la posprueba de ambos grupos. El valor de W fue de a 777, para un valor p de 0.2782. Aunque las puntuaciones de las pospruebas del grupo colaborativo fueron mayores que las puntuaciones de la posprueba del grupo individual, la diferencia no fue estadisticamente significativa.

  17. CHOQUES AGREGADOS E INVERSIÓN EN CAPITAL HUMANO: EL LOGRO EDUCATIVO SUPERIOR DURANTE LA DÉCADA PERDIDA EN MÉXICO

    PubMed Central

    Peña, Pablo A.

    2014-01-01

    Este artículo documenta una respuesta agregada negativa del logro educativo superior (más de 12 años de escolaridad) en México a la recesión de 1982–83 y el estancamiento que le siguió. La respuesta no fue homogénea entre géneros, regiones y entornos familiares. Los hombres experimentaron una caída en el logro mientras que las mujeres experimentaron un crecimiento más lento. En promedio, los estados con un mayor logro antes del choque experimentaron mayores caídas. La respuesta entre distintos entornos familiares no presenta un patrón claro. Sin embargo, el efecto negativo en el logro se observa incluso entre hermanos. La evidencia sugiere una historia por el lado de la demanda: la caída en el ingreso de los hogares parece ser el determinante de la caída/desaceleración del logro educativo superior. La conclusión es que la recesión y la falta de crecimiento que le siguió tuvieron un efecto negativo importante y duradero en la formación de capacidades en México. PMID:25328251

  18. Esquizofrenia y trastorno en el consumo de sustancias: prevalencia y characterísticas sociodemográficas en la población Latina

    PubMed Central

    Jiménez-Castro, Lorena; Raventós-Vorst, Henriette; Escamilla, Michael

    2012-01-01

    El interés por comprender la co-morbilidad de la esquizofrenia y el trastorno en el uso de sustancias, ha aumentado debido al incremento de este diagnóstico, a los efectos negativos observados en el sujeto y a los costos en los servicios de salud. Este trastorno dual puede tener efectos dramáticos en el curso clínico del trastorno psicótico tales como: mayores recaídas, re-hospitalizaciones, síntomas más severos, no adherencia al tratamiento antipsicótico, cambios marcados del humor, aumento en el grado de hostilidad e ideación suicida, así como alteraciones en otras áreas del funcionamiento incluyendo violencia, victimización, indigencia y problemas legales. La literatura proveniente en particular de Estados Unidos y Europa sugiere que el rango de prevalencia para este diagnóstico puede oscilar entre el 10% hasta el 70%. En este estudio, revisamos la prevalencia del diagnóstico dual de esquizofrenia y trastorno en el uso sustancias, así como sus características sociodemográficas, con base en la literatura disponible alrededor del mundo dando énfasis en la poblacion latina. A pesar de que este diagnóstico es ampliamente aceptado, se conoce poco sobre su prevalencia en la población latina, sobre los factores ambientales, demográficos, clínicos y otras características de estos individuos. Un mejor conocimiento sobre este diagnóstico permitiría mejorar los métodos para la detección y adecuada valoración del trastorno en el uso de sustancias en personas con trastornos metales severos como la esquizofrenia. PMID:21404151

  19. Sistema Planeta-Satélite. Simulación orbital y potenciales gravitatorios

    NASA Astrophysics Data System (ADS)

    Medina, C.; Carrillo, M.

    Se presenta un programa (desarrollado en Quick Basic 4.5) que simula, en tres dimensiones, el movimiento orbital de un satélite (o luna) alrededor de un planeta, al tiempo que calcula y grafica, en un plano, el potencial gravitatorio del sistema en función de la distancia al planeta. Para la simulación orbital, se emplea la matriz de transformación entre el sistema del planeta y el plano orbital. Para el cálculo y graficación del potencial se aplica un desarrollo en serie hasta el segundo orden, que da cuenta del efecto de achatamiento de los polos, en caso de que éste exista. Las longitudes de los ejes del planeta, la masa de éste y del satélite, sus tamaños aparentes, y los parámetros orbitales son introducidos por el usuario.

  20. Efectos de la radiación UV en la salud

    EPA Pesticide Factsheets

    La reducción de la capa de ozono disminuye la protección natural que ofrece nuestra atmósfera contra la radiación ultravioleta (UV) perjudicial del sol. Esta página web proporciona una descripción general de los principales problemas de salud relacionados

  1. Efectos del material particulado (PM) sobre la salud y el medioambiente

    EPA Pesticide Factsheets

    El tamaño de las partículas se encuentra directamente vinculado con el potencial para provocar problemas de salud. La exposición a estas partículas puede afectar tanto a los pulmones como al corazón. También afectan el medioambiente.

  2. Analisis de Alteraciones EN la Imagen Debidas a Descolimacion de un Telescopio

    NASA Astrophysics Data System (ADS)

    Cobos, F. J.; Galan, M. J.

    1987-05-01

    Podemos considerar, en términos generales, que los espejos de un telescopio tienen una calidad óptica intrínseca, entendiendo por ésta la que se ha obtenido como resultado, fundamentalmente, de la destreza del personal del Taller Optico, que considerará terminadas las superficies ópticas cuando éstas satisfagan los requisitos de diseño y las pruebas de evaluación pertinentes. Debemos esperar que, una vez instalados los espejos en el telescopio, no se altere esta calidad de la óptica por un funcionamiento inadecuado de partes mecánicas del mismo. En los últimos años, en la medida que los problemas de infraestructuratura de nuestros Observatorios se han ido resolviendo, se ha hecho más patente la necesidad de llevar a la instrumentación existente al máximo de su potencial y parte esencial de ésta la conforman los mismos te lescopios. Mejorar la calidad óptica de las imágenes obtenidas con ellos ha hecho que sea prioritario el realizar una investigación más sistemática de sus características. Este trabajo ha tenido como objetivo primordial el usar un programa de diseño óptico, en el caso particular del telescopio UNAM212, con el fin de calcular y obtener gráficamente los diagramas de manchas de imagenes en foco y extrafocales, tanto con la óptica perfectamente alineada como descolimándola (mediante pequenos giros y descentramientos de los espejos). De esta manera, se hizo una evaluación de los efectos que estas alteraciones simuladas producirían en las imágenes focales y extra focales para así poder compararlas con las que realmente se han observado. Asimismo, se ha buscado información bibliográfica, en particular sobre los efectos de giros y descentramientos en las imágenes extrafocales, en lo que se ref iere a la falta de concentricidad de los círculos que forman la "dona" y a la distribución de intensidad luminosa en la misma. De ésta, l futuro un proceso que, haciendo uso de los detectores bidimensionales, nos permita Ilevar a cabo una alineación más rigurosa de la óptica del telescopio y evaluar con precisión Si variaciones en el posicionado del misesperamos desarrollar en emo producen efectos de descolimación.

  3. PubMed

    Camporro, Fernando Astur; Gutierrez Magaldi, Ignacio; Bulacio, Exequiel

    2017-09-08

    Introducción: El tabaquismo es la primera causa evitable de muerte en el mundo. El cigarrillo electrónico (CE), es un dispositivo que simula a los cigarrillos convencionales y permite inhalar nicotina y otras sustancias de forma vaporizada, sin combustión de tabaco. Su conocimiento por parte de la población general, así como su comercialización y consumo viene en constante aumento. Es utilizado en todo el mundo con el objetivo de disminuir el consumo de tabaco, lograr su abandono o poder utilizarlo en lugares públicos donde el consumo de cigarrillos convencionales está prohibido. Efectos nocivos sobre la salud: Su utilización se ha asociado a neumonía lipoidea e irritación de la vía aérea superior y toxicidad por nicotina. Presenta sustancias cancerígenas como nitrosaminas, formaldeido y metales como el niquel, cromo y plomo. Aumenta la resistencia de la vía aérea, efecto que es similar al que se produce después de la inhalación del humo del tabaco. Eficacia para dejar de fumar: No hay hasta el momento trabajos que demuestren con poder estadístico y buena metodología que este producto sea eficaz para dejar de fumar.  Conclusiones: De acuerdo a la evidencia disponible, no podemos descartar que el uso del cigarrillo electrónico no tenga riesgos para la salud. La seguridad y eficacia de los cigarrillos electrónicos como ayuda para el abandono del hábito tabáquico no han sido demostradas.

  4. [Not Available].

    PubMed

    Aguilera Eguía, Raúl; Jorquera Pino, Paula Jessica; Salgado, Claudia Jaqueline; Flores, Cherie

    2016-07-19

    Introducción: según la Organización Mundial de la Salud, la obesidad se puede definir como una acumulación anormal o excesiva de grasa que puede ser yatrogénica para la salud.Objetivo: resumir las revisiones sistemáticas Cochrane y no Cochrane que evalúen el efecto de la suplementación de calcio para la disminución del Índice de masa corporal en personas obesas.Materiales y métodos: se realizó una búsqueda en la base de datos Medline (1980 - septiembre de 2015), Metabuscador TripDatabase y Epistemonikos (hasta septiembre de 2015), Cochrane BVS (hasta septiembre de 2015); se buscó de forma manual en revistas relacionadas con el tema de interés; se buscaron actas de congresos y se realizaron seguimientos de referencias relevantes y se contactó con expertos en el área.Resultados: la búsqueda preliminar arrojó un total de 7.163 artículos potencialmente elegibles. Según los criterios de elegibilidad incluimos dos revisiones sistemáticas de estudios clínicos aleatorizados.Conclusión: el suplemento de calcio, al parecer, no incidiría en la disminución del índice de masa corporal, DM 0,12 (-0,62, 0,86); p = 0,75, presentando "muy baja evidencia" según GRADE, esto quiere decir que "presenta una gran incertidumbre sobre la estimación del efecto".

  5. Ecologia de las lombrices de tierra

    Treesearch

    Grizelle Gonzalez

    2014-01-01

    De los organismos de suelo, las lombrices de tierra son las mas conocidas y a menudo son consideradas las mas importantes por su influencia en el funcionamiento de ecosistemas de suelo (Hendriz y Bohlen, 2002). Tienen un efecto significativo en la estructura del suelo, el ciclo de nutrimentos y ls productividad de las cosechas. En terminos de biomasa, generalmente...

  6. Effects of a 12-hour shift on mood states and sleepiness of Neonatal Intensive Care Unit nurses.

    PubMed

    Ferreira, Tadeu Sartini; Moreira, Clarice Zinato; Guo, James; Noce, Franco

    2017-03-09

    To assess the effect of a 12-hour shift on mood states and sleepiness at the beginning and end of the shift. Quantitative, cross-sectional and descriptive study.It was conducted with 70 neonatal intensive care unit nurses. The Brunel Mood Scale (BRUMS), Karolinska Sleepiness Scale (KSS), and a socio-demographic profile questionnaire were administered. When the KSS and BRUMS scores were compared at the beginning of the shift associations were found with previous sleep quality (p ≤ 0.01), and quality of life (p ≤ 0.05). Statistical significant effects on BRUMS scores were also associated with previous sleep quality, quality of life, liquid ingestion, healthy diet, marital status, and shift work stress. When the beginning and end of the shift were compared, different KSS scores were seen in the group of all nurses and in the night shift one. Significant vigor and fatigue scores were observed within shift groups. A good night's sleep has positive effects on the individual`s mood states both at the beginning and the end of the shift. The self-perception of a good quality of life also positively influenced KSS and BRUMS scores at the beginning and end of the shift. Proper liquid ingestion led to better KSS and BRUMS scores. Evaluar el efecto de un turno de 12 horas en estados de ánimo y somnolencia al principio y al final del turno. Estudio cuantitativo, transversal y descriptivo.Se realizó con 70 enfermeras de unidades de cuidados intensivos neonatales. Se administró la Escala de Humor Brunel (BRUMS), la Escala de Somnolencia de Karolinska (KSS) y un cuestionario de perfil sociodemográfico. Cuando se compararon las puntuaciones de KSS y BRUMS al comienzo del turno se encontraron asociaciones con calidad de sueño previa (p ≤ 0,01) y calidad de vida (p ≤ 0,05). Los efectos estadísticos significativos en las puntuaciones de BRUMS también se asociaron con la calidad previa del sueño, la calidad de vida, la ingestión de líquidos, la dieta saludable, el estado civil y el estrés laboral por turnos. Cuando se compararon el comienzo y el final del turno, se observaron diferentes puntuaciones de KSS en el grupo de todos los enfermeros y en el turno de noche. Se observaron puntuaciones significativas de vigor y fatiga dentro de los grupos de turnos. Dormir bien de noche tiene efectos positivos en los estados de ánimo del individuo tanto al principio como al final del turno. La autopercepción de una buena calidad de vida también influyó positivamente en las puntuaciones KSS y BRUMS al inicio y al final del turno. La ingesta de líquidos adecuada condujo a mejores puntuaciones KSS y BRUMS.

  7. [Not Available].

    PubMed

    Fernández Castillo, Rafael; Cañadas de la Fuente, Gustavo R; Cañadas de la Fuente, Guillermo A; De la Fuente Solana, Emilia Inmaculada; Esteban de la Rosa, Rafael José; Bravo Soto, Juan

    2016-07-19

    Introducción: la obesidad y el sobrepeso presentan efectos adversos sobre la salud, lo que contribuye a la aparición de enfermedades metabólicas y cardiovasculares que ponen en peligro la integridad del injerto.Objetivo: investigar la influencia del IMC pretrasplante renal sobre el funcionamiento del injerto renal al año de trasplante mediante el estudio de cuatro métodos distintos de medir la filtración glomerular.Material y métodos: en este trabajo se ha seguido a 1.336 pacientes de ambos sexos trasplantados renales; se les realizaron mediciones pretrasplante y postrasplante de parámetros bioquímicos, mediciones antropométricas y función renal mediante medidas de filtrado glomerular.Resultados: a mayor índice de masa corporal pretrasplante se produce una disminución del filtrado glomerular medido por cuatro métodos distintos, así como mayor porcentaje de rechazos.Conclusiones: un IMC elevado pretrasplante contribuye a la disfunción del injerto, a una disminución del filtrado glomerular y a complicaciones del injerto en el primer año postrasplante.

  8. Estudio multifrecuencia del medio interestelar cercano a HD 192281

    NASA Astrophysics Data System (ADS)

    Arnal, E. M.; Cappa, C.; Cichowolski, S.; Pineault, S.; St-Louis, N.

    Una de las causas que modifica la estructura y dinámica del medio interestelar es la acción que los vientos de las estrellas de gran masa ejercen sobre el mismo. En este trabajo, mediante el uso de datos interferométricos obtenidos en la banda de radio en la transición de 21-cm del Hidrógeno neutro y de imágenes de la emisión de continuo en las bandas de 408 y 1420 MHz, de imágenes HIRES del satélite IRAS en 60 y 100 micrones, y de observaciones de continuo obtenidas con radiotelescopios de disco simple en 2695, 4850 y 8350 MHz se ha realizado un estudio multifrecuencia de los efectos que los vientos estelares de HD 192281, una estrella de tipo espectral O5 Vn((f))p, han tenido sobre el medio interestelar que rodea a la misma.

  9. Estudio multifrecuencia del medio interestelar cercano a HD 192281

    NASA Astrophysics Data System (ADS)

    Arnal, E. M.; Cappa, C. E.; Cichowolski, S.; Pineault, S.; St-Louis, N.

    Una de las causas que modifica la estructura y dinámica del medio interestelar es la acción que los vientos de las estrellas de gran masa ejercen sobre el mismo. En este trabajo, mediante el uso de datos interferométricos obtenidos en la banda de radio en la transición de λ˜21-cm del hidrógeno neutro y de imágenes de la emisión de continuo en las bandas de 408 y 1420 MHz, de imágenes HIRES del satélite IRAS en 60 y 100μm, y de observaciones de continuo obtenidas con radiotelescopios de disco simple en 2695, 4850 y 8350 MHz se ha realizado un estudio multifrecuencia de los efectos que los vientos estelares de HD 192281, una estrella de tipo espectral O5,Vn((f))p, han tenido sobre el medio interestelar que rodea a la misma.

  10. Efecto del Programa de Entrenamiento “Manejo del Dolor” en la Documentación de Enfermería en el Expediente Electrónico

    PubMed Central

    Monsiváis, María Guadalupe Moreno; Guzmán, Ma. Guadalupe Interial; Flores, Paz Francisco Sauceda; Arreola, Leticia Vázquez

    2012-01-01

    Resumen En el presente trabajo se muestra la importancia de entrenar al personal de enfermería para mejorar la documentación en el expediente electrónico. Se eligió el manejo del dolor por ser un área prioritaria; una alta proporción de pacientes en período post operatorio cursa con dolor, por lo tanto, la documentación debe ser útil para la toma de decisiones clínicas. Se implementó un programa de entrenamiento denominado “Manejo del Dolor” dirigido al personal de enfermería. Se utilizó la tecnología de la información como herramienta para fortalecer el conocimiento con base en la revisión sistemática de la literatura; el personal de enfermería participante seleccionó la mejor evidencia; posteriormente se trabajó en la transferencia de este conocimiento a la práctica a través del diseño de un protocolo para el manejo del dolor. Se concluye que el conocimiento del manejo del dolor es fundamental para que enfermería documente con mayor precisión sus intervenciones. PMID:24199106

  11. Relevamiento de HI en el Hemisferio Austral

    NASA Astrophysics Data System (ADS)

    Arnal, E. M.; Bajaja, E.; Morras, R.; Pöppel, W. G. L.

    Un nuevo relevamiento de HI de todo el Hemisferio Austral, comprendido entre -90o <= δ <= -25o, está siendo observado con la antena I del IAR. El mismo es realizado con alta sensibilidad (r.m.s.<= 0.07 K) y alta resolución espectral (1 Km/s). Un total de ~50000 posiciones en el cielo serán observadas, espaciadas en una grilla (lxb) de (0.5o x 0.5o). El intervalo de velocidades cubierto en este relevamiento abarca el rango -450 km/s a +450 km/s en el sistema LSR. Esta base de datos será corregida por efectos de ``stray radiation''. Al presente se ha observado ~70% del total del relevamiento. El mismo es complementario de uno similar realizado en el Hemisferio Norte por Hartman y Burton (1996), con cubrimiento espacial, sensibilidad, resoluciones espaciales y en velocidad, similares a los del IAR. El objetivo final de ambos relevamientos es disponer de una base de datos uniforme en todo el cielo.

  12. PubMed

    Litewka, Sergio G

    2010-11-01

    Argentina ha sido un campo fértil para los intentos de reforma del sector salud, en la búsqueda por mejorar la calidad de sus servicios y, consecuentemente, la accesibilidad y la equidad del mismo. Los resultados obtenidos no han sido proporcionales a los esfuerzos desarrollados. Aunque la bioética debería, como forma de reflexión interdisciplinaria, participar en la fundamentación de nuevas políticas sanitarias y sus efectos sobre los usuarios, parece haber permanecido ajena, en general, a los graves problemas derivados de la corrupción, prefiriendo enfocarse en cuestiones vinculadas a planteos abstractos de justicia y solidaridad, atribuyendo los fracasos a la imposición de modelos económicos foráneos.

  13. [Not Available].

    PubMed

    Sendrós Madroño, José M

    2016-06-03

    La atención nutricional en el paciente oncohematológico debe formar parte del tratamiento global del paciente. Las alteraciones debidas a la localización de la neoplasia y los efectos secundarios del tratamiento oncoespecífico muchas veces dificultan o impiden la alimentación oral. Esto puede dar lugar a una desnutrición y es de gran importancia su detección, valoración e intervención temprana. El primer paso en la intervención nutricional es el consejo dietético. Este artículo muestra qué aspectos deben tenerse en cuenta para poder elaborar un consejo dietético y la importancia de que este sea individualizado. Se describen como ejemplo cuatro situaciones especiales, donde es necesario trasladar las recomendaciones nutricionales a un plan dietético. También se incide en el uso de los probióticos en pacientes inmunocomprometidos.

  14. La Exploracion Del Contexto Social y Sus Efectos en el Programa de Espanol en Mexico Rural. (Exploring the Social Context Affecting a Pre-School Spanish Program in Rural Mexico).

    ERIC Educational Resources Information Center

    Finegold, Lynda

    A major stumbling block for the implementation of Mexico's Global Development Plan has been the country's large rural population of Indians. One government strategy to integrate this sector into the mainstream of society has been to teach Spanish, the official language, as a second language, while at the same time fostering ethnic pride. The…

  15. Vigilando la Calidad del Agua de los Grandes Rios de la Nacion: El Programa NASQAN del Rio Grande (Rio Bravo del Norte)

    USGS Publications Warehouse

    Lurry, Dee L.; Reutter, David C.; Wells, Frank C.; Rivera, M.C.; Munoz, A.

    1998-01-01

    La Oficina del Estudio Geologico de los Estados Unidos (U.S. Geological Survey, 0 USGS) ha monitoreado la calidad del agua de la cuenca del Rio Grande (Rio Bravo del Norte) desde 1995 como parte de la rediseiiada Red Nacional para Contabilizar la Calidad del Agua de los Rios (National Stream Quality Accounting Network, o NASOAN) (Hooper and others, 1997). EI programa NASOAN fue diseiiado para caracterizar las concentraciones y el transporte de sedimento y constituyentes quimicos seleccionados, encontrados en los grandes rios de los Estados Unidos - incluyendo el Misisipi, el Colorado y el Columbia, ademas del Rio Grande. En estas cuatro cuencas, el USGS opera actualmente (1998) una red de 40 puntos de muestreo pertenecientes a NASOAN, con un enfasis en cuantificar el flujo en masa (la cantidad de material que pasa por la estacion, expresado en toneladas por dial para cada constituyente. Aplicacando un enfoque consistente, basado en la cuantificacion de flujos en la cuenca del Rio Grande, el programa NASOAN esta generando la informacion necesaria para identificar fuentes regionales de diversos contaminantes, incluyendo sustancias qui micas agricolas y trazas elementos en la cuenca. EI efecto de las grandes reservas en el Rio Grande se puede observar segun los flujos de constituyentes discurren a 10 largo del rio. EI analisis de los flujos de constituyentes a escala de la cuenca proveera los medios para evaluar la influencia de la actividad humana sobre las condiciones de calidad del agua del Rio Grande.

  16. [Not Available].

    PubMed

    Vizuet Vega, Norma Isela; Shamah Levy, Teresa; Gaona Pineda, Elsa Berenice; Cuevas Nasu, Lucía; Méndez Gómez-Humarán, Ignacio

    2016-07-19

    Introducción: la anemia es un factor de riesgo en la población infantil con consecuencias graves para su crecimiento y desarrollo. Los programas de ayuda alimentaria pueden contribuir a su prevención y control. Objetivo: estudiar la adherencia al consumo de suplementos y su relación con la prevalencia de anemia en niños menores de tres años de edad en San Luis Potosí, México beneficiarios del programa PROSPERA.Métodos: se realizó un análisis comparativo en niños de 12 a 36 meses que consumen diferentes suplementos alimenticios: 414 pertenecientes al grupo de intervención y 334 al de comparación. Se midió la hemoglobina (Hb) por Hemocue clasificando como anémicos a quienes tuvieron valores <110 g/l. Se aplicaron pruebas de t de Student y X2. Se estimaron efectos de intervención mediante el método de diferencias en diferencias y un puntaje de adherencia al consumo de suplementos.Resultados: al final del estudio la prevalencia de anemia disminuyó 11.2 pp en el grupo de intervención y 8.7 pp en el de comparación; la interacción del puntaje de adherencia por suplemento y etapa de observación mostró que la adherencia al consumo de Bebida láctea + Vitaniño reduce el riesgo de presentar anemia (p = 0,14). El consumo de Nutrisano + Vitaniño se asoció con menor riesgo (0,2), ambos con respecto al consumo de Nutrisano.Conclusiones: el programa PROSPERA tuvo efectos importantes en la disminución de las prevalencias de anemia. Se recomienda llevar a cabo acciones para mejorar la adherencia al consumo de suplementos alimenticios, a fIn de mejorar la efectividad de los programas.

  17. QUALITY, HEALTH SYSTEM AND GOVERNANCE. THE ARGENTINEAN CASE

    PubMed Central

    Litewka, Sergio G.

    2011-01-01

    Argentina ha sido un campo fértil para los intentos de reforma del sector salud, en la búsqueda por mejorar la calidad de sus servicios y, consecuentemente, la accesibilidad y la equidad del mismo. Los resultados obtenidos no han sido proporcionales a los esfuerzos desarrollados. Aunque la bioética debería, como forma de reflexión interdisciplinaria, participar en la fundamentación de nuevas políticas sanitarias y sus efectos sobre los usuarios, parece haber permanecido ajena, en general, a los graves problemas derivados de la corrupción, prefiriendo enfocarse en cuestiones vinculadas a planteos abstractos de justicia y solidaridad, atribuyendo los fracasos a la imposición de modelos económicos foráneos. PMID:21660255

  18. Efectos del huracán Georges en la composición de especies y estructura de un bosque secundario en el interior de Puerto Rico

    Treesearch

    A.E. Lugo; C.M. Domínguez Cristóbal; N. Méndez Irizarry

    2005-01-01

    From 1995 to 2003 we studied species composition and structure in a secondary subtropical wet forest in Utuado Puerto Rico. During September 21-22, 1998, hurricane Georges passed through the stand with maximum sustained winds of 184 km/h and gusts of 240 km/h. Species richness increased after the hurricane. While native species Miconia prasina reduced its Importance...

  19. Population size and selection intensity effects on short-term response for a selection index in Tribolium.

    PubMed

    Campo, J L; Turrado, H

    1997-01-12

    The effects of population size and selection intensity on the short-term response to selection were investigated in an experiment with Tribolium, using a two-trait empirical selection index for pupal and adult weights. Twenty lines were selected following a factorial design of five population sizes (1, 2, 4, 8, and 16 pairs of parents) and four selection intensities (20, 25, 33, and 50%), with three replicates. For each replicate, an unselected control with 16 pairs of parents was produced. There were four generations of selection per line. Selection response was significant in all lines with the 20% selection intensity and/or the 16-pair population size. Selection intensity and population size were significant effects and there was significant interaction between them. Higher selection intensities produced more overall significant response to selection (20% > (25% = 33%) > 50%); this significance was also found for the 16-pair population size. There was an overall significant difference among population sizes, with the larger population sizes giving more response than the smaller sizes (16-pair = 8-pair = 4-pair) > (2-pair = 1-pair); this significance was also found for the 20% selection intensity. There was a good agreement between observed and expected responses, except for the 50% selection intensity and/or 1-pair population size; expected values in generation 1 overestimated observed values. The realized heritability was similar in all lines. With equal and high numbers of individuals scored, it was better to choose a high selection intensity than a large population size. The results show that the effect of population size cannot be ignored, even in short-term selection response; the main influence of population size is through selection differential. RESUMEN: Los efectos del tamaño de población y la intensidad de selección sobre la respuesta a corto plazo para un índice de selección en Tribolium Los efectos del tamaño de población y la intensidad de selección sobre la respuesta a la selección a corto plazo fueron estudiados en un experimento con Tribolium usando un índice empírico de selección para dos caracteres (peso de pupa y peso adulto). Se seleccionaron 20 líneas siguiendo un modelo factorial de cinco tamaños de población (1, 2, 4, 8 y 16 pares de padres) y cuatro intensidades de selección (20, 25, 33 y 50%), con tres repeticiones. En cada repetición, había una línea control sin seleccionar con 16 pares de padres. Se hicieron cuatro generaciones de selección, por línea. La respuesta a la selección fue significativa en todas las líneas con el 20% de intensidad de selección y/o 16 pares de padres. Tanto la intensidad de selección como el tamaño de población fueron efectos significativos y hubo interacción significativa entre ellos. Las intensidades de selección más altas produjeron significativamente más respuesta en general (20% > (25% = 33%) > 50%), y esta significación se mantenía cuando el tamaño de población era de 16 pares de padres. Hubo diferencias significativas entre tamaños de población, dando los mayores tamaños más respuesta en general que los menores tamaños (16 pares = 8 pares = 4 pares) > (2 pares = 1 par), manteniendose esta significación para la intensidad de selección del 20%. La concordancia entre las respuestas observadas y las esperadas era buena, excepto cuando la intensidad de selección era 50% y/o el tamaño de población era 1 par de padres; los valores esperados en la generación 1 sobreestimaban los valores observados. La heredabilidad realizada fue similar en todas las líneas. Cuando el número total de animales era igual y alto, era mejor elegir una intensidad de selección alta que un tamaño de población grande. Los resultados indican que el efecto del tamaño de población no se puede ignorar incluso en experimentos de selección a corto plazo, y que la influencia principal de este efecto es a través del diferencial de selección. 1997 Blackwell Verlag GmbH.

  20. Regulación del flujo sanguíneo uterino. I. Funciones de estrógeno y receptores estrogénicos α/β en el endotelio vascular uterino durante el embarazo

    PubMed Central

    Mayra, Pastore R.; Rosalina, Villalón L.; López, Gladys; Iruretagoyena, Jesús; Magness, Ronald

    2015-01-01

    Resumen El estrógeno y los receptores estrogénicos clásicos (REs), RE-α y RE-β, han demostrado ser parcialmente responsable por las adaptaciones endoteliales uterinas durante el embarazo al corto y largo plazo. Las diferencias moleculares y estructurales, junto con los diferentes efectos causados por estos receptores en las células y los tejidos, sugieren que su función varía dependiendo de la manera en la cual el estrógeno se comunica con sus receptores. En ésta revisión bibliográfica se discuten la función del estrógeno y sus receptores clásicos en las adaptaciones cardiovasculares durante el embarazo y la expresión de los Res in vivo e in vitro en el endotelio de la arteria uterina durante el ciclo ovárico y el embarazo, a la vez comparado con la expresión en endotelio arterial de tejidos reproductivos y no reproductivos. Estos temas integran el conocimiento actual de este amplio campo científico con interpretaciones e hipótesis diversas relacionadas con los efectos estrogénicos mediados bien sea por uno o los dos REs. Esta revisión también incluye la relación con las adaptaciones vasodilatadoras y angiogénicas requeridas para modular el dramático incremento fisiológico en la perfusión útero-placentaria observada durante un embarazo normal. PMID:26113750

  1. El uso de la neuromodulación para el tratamiento del temblor

    PubMed Central

    Bendersky, Damián; Ajler, Pablo; Yampolsky, Claudio

    2014-01-01

    Introducción: El temblor puede ser un desorden incapacitante y el tratamiento de primera línea para estos pacientes es farmacológico. Sin embargo, este tratamiento puede llevar a una reducción satisfactoria del temblor en sólo el 50% de los pacientes con temblor esencial. La talamotomía era el tratamiento de elección para el temblor refractario al tratamiento médico hasta que comenzó a utilizarse la estimulación cerebral profunda (ECP) del núcleo ventral intermedio (Vim) del tálamo. En la actualidad, raramente se realiza la talamotomía. Métodos: Este artículo es una revisión no sistemática de las indicaciones, resultados, parámetros de programación y técnica quirúrgica de la ECP del Vim para el tratamiento del temblor. Resultados: Aunque los resultados clínicos son similares usando la talamotomía o la ECP del Vim, la primera causa más efectos adversos que la última. Además, la ECP puede ser usada bilateralmente, mientras que la talamotomía tiene un alto riesgo de causar disartria cuando se realiza de ambos lados. La ECP del Vim logró una adecuada mejoría del temblor en varias series de pacientes con temblor causado por temblor esencial, enfermedad de Parkinson o esclerosis múltiple. Además del Vim, hay otros blancos que están siendo usados por varios autores, tales como la zona incerta y las radiaciones prelemniscales. Conclusión: La ECP del Vim es un tratamiento útil para el temblor incapacitante refractario al tratamiento médico. Es esencial realizar una precisa selección de pacientes, así como utilizar una técnica quirúrgica correcta. Aún se desconoce el mejor blanco estereotáctico para el temblor, aunque el Vim es el más usado. PMID:25165613

  2. Efectos Especiales de Anclaje (Estudio sobre Regresiones de Juicios Condicionales). Parte 2: Invariancia del Juicio No-Condicional Como Valor Estandar Para el Juicio Condicional (Special Effects of Anchoring (Study of Regression of Conditional Judgements) Part 2: Invariance of Unconditional Judgments as Standard Value for the Conditional Judgment). Publication No. 31.

    ERIC Educational Resources Information Center

    Lopez Alonso, A. O.

    From the best-fit lines corresponding to sets of families of conditional judgements, the constant stimulus family and the constant condition family, both defined for a same scale object, the coordinate values of the point of intersection of both lines (indifference point) are obtained. These values are studied in relation to the mean values of the…

  3. PubMed

    Bueno Vargas, Pilar; Manzano Martín, Manuel; López-Aliaga, Inmaculada; López Pedrosa, José M ª

    2016-09-20

    Introducción: la gestación y lactancia están relacionadas con pérdidas temporales en la densidad mineral ósea (DMO) materna. Una suplementación con calcio podría resultar beneficiosa para evitar la pérdida de masa ósea del esqueleto materno. Otros nutrientes como los prebióticos han sido identificados como responsables de un incremento en la absorción de minerales, pudiendo condicionar la mineralización ósea.Objetivo: estudiar el efecto de la suplementación de la dieta materna con el prebiótico inulina enriquecida con oligofructosa, durante la gestación y la lactancia sobre el contenido mineral óseo (CMO) y la DMO al final del periodo de lactancia.Métodos: las ratas gestantes fueron alimentadas con dieta estándar (grupo CC), dieta fortificada en calcio (grupo Ca) o enriquecida con el prebiótico inulina enriquecida con oligofructosa (grupo Pre) hasta el final del periodo de lactancia. Posteriormente se evaluó el CMO y DMO por absorciometría de rayos X (DEXA) y el pH del contenido cecal.Resultados:en términos generales, el grupo Pre presenta los mayores valores absolutos de CMO y DMO de entre los tres grupos, siendo en la tibia significativamente diferentes en los grupos CC y Pre frente al grupo Ca. El pH del contenido cecal del grupo Pre es significativamente inferior al de los grupos CC y Ca.Conclusión:la suplementación con inulina enriquecida con oligofructosa, en condiciones nutricionales no deficientes en calcio, durante la gestación y la lactancia, ejerce una protección del esqueleto materno en las ratas y puede ser considerada como una estrategia nutricional para proteger la masa ósea materna en el periodo perinatal.

  4. Hacia el consumo informado de tabaco en México: efecto de las advertencias con pictogramas en población fumadora

    PubMed Central

    Thrasher, James F; Pérez-Hernández, Rosaura; Arillo-Santillán, Edna; Barrientos-Gutiérrez, Inti

    2015-01-01

    Resumen Objetivo Evaluar el efecto de las advertencias sanitarias (AS) con pictogramas en las cajetillas de tabaco en adultos fumadores. Material y métodos Cohorte de fumadores con representatividad poblacional de siete ciudades mexi canas, antes (2010) y después (2011) de la implementación de AS con pictogramas (ASP). Para determinar el cambio en las variables sobre el impacto cognitivo y conductual de las advertencias, se estimaron modelos bivariados y ajustados de ecuaciones de estimación generalizada. En el Segundo levantamiento (2011), se estimaron modelos para determiner los factores que se asocian con el reporte de recordar cada advertencia que había entrado al mercado, además de los factores asociados con el autorreporte del impacto de cada advertencia vigente. Resultados Se observaron incrementos importantes de 2010 a 2011 en los conocimientos sobre los riesgos de fumar, los componentes tóxicos del tabaco y el número telefónico para recibir consejos sobre dejar de fumar. La recordación e impacto de las primeras advertencias con pictogramas parecen ser amplios y equitativos a través de la población fumadora. En comparación con 2010, un mayor nivel de ex fumadores entrevistados en 2011 reportaron que las advertencias habían influido mucho en dejar de fumar (RM=2.44, 95% IC 1.27–4.72). Conclusiones Las AS con pictogramas han logrado un impacto importante en el conocimiento y conducta, información relevante para la población y en tomadores de decisiones. PMID:22689162

  5. [In Process Citation].

    PubMed

    Caravalí-Meza, Nuris Yohana; Jiménez-Cruz, Arturo; Bacardí-Gascón, Montserrat

    2016-03-25

    Antecedentes: se ha reportado una asociación entre el aumento del consumo de bebidas azucaradas y varias enfermedades metabólicas. Objetivo: evaluar el efecto del consumo de bebidas azucaradas sobre la obesidad en un periodo de 12 meses en mexicanos de 15 a 19 años. Métodos: el diseño del estudio fue prospectivo, con 12 meses de seguimiento. Se midieron el peso, la talla y la circunferencia de cintura (CC), y se calculó el puntaje z de índice de masa corporal (IMC). Se aplicó un cuestionario sobre consumo de 19 bebidas. Para evaluar la predicción del aumento de IMC y de CC como resultado del consumo de bebidas, se utilizó análisis de regresión logística binomial. Resultados: al final del estudio se evaluó al 89% (1.344). El promedio de edad fue de 15 años, 55% fueron mujeres. La prevalencia de sobre- peso y obesidad al final del estudio fue del 33%. Al final del estudio, un 25% de los participantes consumían más de 50 g de azúcar proveniente de las bebidas. Quienes consumieron 50 g de azúcar o más al día presentaron mayor riesgo de aumentar la CC ≥ 2 cm (RR = 1,19, IC 95%, 1,03-1,39, p = 0,02). Quienes mantuvieron el consumo de bebidas azucaradas durante 12 meses, al compararlo con los que disminuyeron el consumo a 10 g/día, presentaron 71% más probabilidades de aumentar a un puntaje de IMC ≥ 2 (RR = 1,71, IC 95%, 1,03-2,86, p = 0,039). Conclusión: el alto consumo de bebidas azucaradas aumentó las probabilidades de aumentar de peso y de circunferencia de cintura.

  6. Reliability and construct validity of the Instrument to Measure the Impact of Valve Heart Disease on the Patient's Daily Life.

    PubMed

    Anjos, Daniela Brianne Martins Dos; Rodrigues, Roberta Cunha Matheus; Padilha, Kátia Melissa; Pedrosa, Rafaela Batista Dos Santos; Gallani, Maria Cecília Bueno Jayme

    2016-12-19

    evaluate the practicality, acceptability and the floor and ceiling effects, estimate the reliability and verify the convergent construct's validity with the instrument called the Heart Valve Disease Impact on daily life (IDCV) of the valve disease in patients with mitral and or aortic heart valve disease. data was obtained from 86 heart valve disease patients through 3 phases: a face to face interview for a socio-demographic and clinic characterization and then other two done through phone calls of the interviewed patients for application of the instrument (test and repeat test). as for the practicality and acceptability, the instrument was applied with an average time of 9,9 minutes and with 110% of responses, respectively. Ceiling and floor effects observed for all domains, especially floor effect. Reliability was tested using the test - repeating pattern to give evidence of temporal stability of the measurement. Significant negative correlations with moderate to strong magnitude were found between the score of the generic question about the impact of the disease and the scores of IDCV, which points to the validity of the instrument convergent construct. the instrument to measure the impact of valve heart disease on the patient's daily life showed evidence of reliability and validity when applied to patients with heart valve disease. avaliar a praticabilidade, aceitabilidade e os efeitos teto e chão, estimar a confiabilidade e verificar a validade de construto convergente do Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata em pacientes com valvopatia mitral e/ou aórtica. dados foram obtidos junto a 86 pacientes valvopatas por meio de três etapas: uma entrevista presencial para caracterização sociodemográfica e clínica e as duas outras realizadas por meio de contato telefônico para as aplicações do instrumento (Teste e teste de repetição). quanto à praticabilidade e aceitabilidade, o instrumento foi aplicado com tempo médio de 9,9 minutos e com 110% de respostas, respectivamente. Constatados efeitos teto e chão para todos os domínios, principalmente efeito chão. A confiabilidade foi testada por meio do teste-teste de repetição, obtendo-se evidências de estabilidade temporal da medida. Foram constatadas correlações negativas significantes de moderada a forte magnitude entre o escore da questão genérica sobre o impacto da doença e os escores do IDCV, o que aponta para validade de construto convergente do instrumento. o Instrumento para Mensuração do Impacto da Doença no Cotidiano do Valvopata apresentou evidências de confiabilidade e validade quando aplicado em pacientes com valvopatia. evaluar la viabilidad, aceptabilidad y los efectos techo y suelo, estimar la confiabilidad y verificar la validez de constructo convergente del Instrumento para Medir el Impacto en lo Cotidiano (IDCV) del sujeto con valvulopatías mitral y/o aórtica. los datos fueron obtenidos de 86 pacientes con valvulopatías por medio de tres etapas: una entrevista presencial para caracterización sociodemográfica y clínica y las otras dos realizadas por medio de contacto telefónico para las aplicaciones del instrumento (test y test de repetición). en cuanto a la viabilidad y aceptabilidad, el instrumento fue aplicado con un tiempo promedio de 9,9 minutos y con 110% de respuestas, respectivamente. Fueron constatados los efectos techo y suelo para todos los dominios, principalmente el efecto suelo. La confiabilidad fue comprobada por medio del test de repetición, obteniéndose evidencias de estabilidad temporal de la medida. Fueron constatadas correlaciones negativas significativas de moderada a fuerte magnitud entre el puntaje de la pregunta genérica sobre el impacto de la enfermedad y los puntajes del IDCV, lo que apunta para la validez de constructo convergente del instrumento. el instrumento para medir el impacto de la valvulopatía en lo cotidiano del sujeto, presentó evidencias de confiabilidad y validez cuando aplicado en pacientes con esa enfermedad.

  7. Efectos de la irradiación iónica en hielos de moléculas carbonadas

    NASA Astrophysics Data System (ADS)

    Satorre, M. A.

    En Astrofísica podemos encontrar numerosos contextos en los cuales se observan moléculas en estado sólido que, en condiciones estándar de presión y temperatura, se encontrarían como gases o líquidos. Dichas moléculas se denominan hielos y han sido observadas en nubes densas del medio interestelar, en envolturas circumestelares, en satélites del Sistema Solar, en cometas, etc. Los hielos pueden ser alterados en su composición química debido a diversos factores como por ejemplo variaciones de temperatura o aportes energéticos por parte de la irradiación, ya sea tanto de fotones ultravioleta como de iones. Dependiendo del escenario astrofísico que analicemos, unos factores cobran más importancia que otros. Los experimentos de laboratorio muestran el efecto que produce sobre la composición de los hielos la irradiación iónica, en particular sobre los que contenían alguna molécula con átomos de carbono. Dicha composición se analiza con espectroscopía IR en el rango de 2 a ˜ 25μ m. La aplicabilidad de los resultados de los experimentos es distinta dependiendo de la composición química inicial de los hielos, del tipo de ion utilizado y de la dosis total de irradiación. Existen efectos generales de la irradiación sobre la materia en los experimentos de relevancia astrofísica como son: - la formación de nuevas moléculas, que pueden incluir o no el ion incidente; - la progresiva pérdida de hidrógeno (carbonización) cuando irradiamos muestras que originalmente contienen una determinada relación carbono/hidrógeno; - la variación de la temperatura de sublimación que presentan algunos hielos. Esto puede suceder tanto en hielos que estaban presentes antes de la irradiación como en hielos formados por ésta. Se presentará el papel del ion en la formación de nuevas moléculas a partir de las que originalmente se encontraban en el hielo. Al penetrar en él, el ion provoca distintos procesos como rotura de enlaces y excitaciones electrónicas. En la mayor parte de los casos las especies producidas por la rotura del enlace, se recombinan volviendo a formar la molécula original. Sin embargo un pequeño porcentaje es capaz de formar nuevas moléculas. Si el ion queda implantado en el hielo y es reactivo (H+, C+,ldots) podría formar parte de una molécula nueva que incorpora un átomo que inicialmente no se encontraba presente en el hielo. También se presentará un contraejemplo para demostrar que no es posible asegurar que siempre que implantemos un ion reactivo, éste formará parte de nuevas moléculas en la mezcla. También se presentará la formación de nuevas moléculas a partir de la irradiación de hielos de metano, que llevan a la formación de otros compuestos como acetileno, eteno, etano,... en los cuales la relación C/H ha variado. Además de estos compuestos se forma también un residuo carbonoso (refractario) que es estable a temperatura ambiente y cuya composición química no es bien conocida. Por último, el aumento de la temperatura de sublimación es también una consecuencia de la irradiación, aunque la magnitud del aumento depende de la mezcla original y de la irradiación sufrida. Existen moléculas que llegan a variar su temperatura de sublimación en decenas de grados. Para el caso de moléculas carbonadas se forman especies por irradiación que son estables a temperatura ambiente. Con todo ello se muestra que los experimentos de laboratorio pueden ayudarnos a comprender la formación, destrucción y variación de las propiedades físicas de los hielos de interés astrofísico con la irradiación.

  8. El nuevo panorama de la Dinámica Galáctica

    NASA Astrophysics Data System (ADS)

    Pivovaroff, Michael James

    En general, la tendencia imperante en Dinámica Galáctica ha sido considerar que los movimientos estelares son básicamente regulares y que el caos no tiene mayor relevancia en los sistemas estelares. Sin embargo, en el último lustro se vienen acumulando pruebas de la importancia del movimiento caótico en ciertos sistemas estelares que existen en la naturaleza. Por una parte, sobre todo el grupo de David Merritt, lo ha mostrado en los casos de galaxias elípticas con concentraciones centrales de materia; por otra parte, en nuestro propio grupo, lo hemos mostrado para el caso de los satélites galácticos. Las consecuencias de estos hallazgos son tanto de tipo técnico, por la necesidad de construir modelos que contengan órbitas caóticas, como astrofísico, por los efectos del caos sobre la estacionariedad y evolución de los sistemas estelares en los que se presenta.

  9. Refuge-effect hypothesis and the demise of the Dodo.

    PubMed

    Roberts, David L

    2013-12-01

    The Dodo was last sighted on the inshore island of Ile d'Ambre in 1662, nearly 25 years after the previous sighting on the mainland of Mauritius. It has been suggested that its survival on the inshore island is representative of the refuge effect. Understanding what constitutes significant persistence is fundamental to conservation. I tested the refuge-effect hypothesis for the persistence of the Dodo (Raphus cucullatus) on an inshore island beyond that of the mainland population. For a location to be considered a refuge, most current definitions suggest that both spatial and temporal isolation from the cause of disturbance are required. These results suggest the island was not a refuge for the Dodo because the sighting in 1662 was not temporally isolated from that of the mainland sightings. Furthermore, with only approximately 350 m separating Ile d'Ambre from the mainland of Mauritius, it is unlikely this population of Dodos was spatially isolated. Hipótesis del Efecto Refugio y la Desaparición del Dodo. © 2013 Society for Conservation Biology.

  10. Astronomía Gamma desde El Leoncito

    NASA Astrophysics Data System (ADS)

    Rovero, A. C.; Colombo, E.; Sahade, J.; Weekes, T. C.

    La astronomía gamma, en el extremo de energías detectadas hasta el presente, se encuentra en desarrollo en muchas partes del mundo y proporciona resultados sorprendentes a medida que la tecnología avanza en el desarrollo de nuevos detectores. La técnica Cherenkov Atmosférica es la utilizada para la detección, mediante telescopios en tierra, del efecto secundario causado por la radiación gamma de muy altas energías (E ≈ TeV). Por medio de telescopios o arreglos de detectores y utilizando la técnica mencionada, se han podido detectar algunas fuentes puntuales de mucha importancia astrofísica como la Nebulosa del Cangrejo y la galaxia de núcleo activo Markarian 421. El sistema instalado en San Juan, en cooperación con el grupo de Radiación Gamma del Observatorio Whipple, está constituído por tres colectores de 1.5m que registran pulsos de luz generados por las cascadas de partículas producidas por rayos cósmicos de todo tipo al entrar en la atmósfera terrestre. El sistema opera por barrido en ascención recta de la fuente observada que, para esta etapa del experimento, es el Centro Galáctico. Esta fuente extensa es conocida como emisor gamma de energías inferiores al TeV y ha sido observada anteriormente en este rango de energía desde el hemisferio norte pero con elevaciones bajas, situación no óptima para este tipo de técnica. Se presentan los primeros resultados del análisis de los datos obtenidos observando la región del Centro Galáctico, luego de dos años de observaciones, así como una descripción de la técnica Cherenkov Atmosférica y del equipo utilizado en la experiencia.

  11. Distinción Empírica Entre Engagement y Trabajolismo en Enfermeras Hospitalarias de Japón: Efecto Sobre la Calidad del Sueño y el Desempeño Laboral

    PubMed Central

    Kubota, Kazumi; Shimazu, Akihito; Kawakami, Norito; Takahashi, Masaya; Nakata, Akinori; Schaufeli, Wilmar B.

    2016-01-01

    Objetivo El objetivo de este estudio es demostrar la distinción entre engagement y trabajolismo, estudiando su relación con la calidad del sueño y el desempeño laboral. Método Un total de 447 enfermeras de 3 hospitales de Japón fueron entrevistadas mediante un cuestionario autoadministrado que incluía la escala Utrecht (UWES, Utrecht Work Engagement Scale), la Escala de Adicción al Trabajo Holandesa (DUWAS, Dutch Workaholism Scale), preguntas sobre la calidad del sueño (7 ítems) con respecto a (1) dificultad para conciliar el sueño, (2) dificultad para mantener el sueño, (3) despertar temprano por la mañana, (4) dormirse o tomar siestas durante el día, (5) somnolencia diurna excesiva en el trabajo, (6) dificultad para despertarse por la mañana, y (7) despertar cansado en la mañana, y el Cuestionario sobre Salud y Desempeño (CSD) de la Organización Mundial de la Salud. Resultados Los modelos de ecuaciones estructurales demostraron que el engagement se relaciona positivamente con la calidad del sueño y el rendimiento laboral, mientras que el trabajolismo tiene una relación negativa con la calidad del sueño y el desempeño laboral. Conclusión Los resultados indican que el engagement y el trabajolismo son conceptualmente diferentes. El primero tiene una connotación positiva, mientras que el segundo se asocia de manera negativa al bienestar (buena calidad del sueño y buen rendimiento en el trabajo). PMID:26752805

  12. Effects of the application of therapeutic massage in children with cancer: a systematic review.

    PubMed

    Rodríguez-Mansilla, Juan; González-Sánchez, Blanca; Torres-Piles, Silvia; Martín, Jorge Guerrero; Jiménez-Palomares, María; Bellino, Macarena Núñez

    2017-06-08

    to learn about the effects of the use of therapeutic massage in children with cancer. systematic review of controlled clinical trials The search was conducted in November 2014 in the following databases: Pubmed, CSIC, Dialnet, Scopus, Cochrane and PEDro. Inclusion criteria were: clinical trials, published in English or Spanish, analyzing the effects of massage on the different stages and types of childhood cancer (between 1 and 18 years old). of 1007 articles found, 7 met the inclusion criteria. Their authors use different massage techniques (Swedish massage, effleurage, petrissage, frictions, pressures), obtaining benefits in the symptoms present during the illness (decrease of pain, nausea, stress, anxiety and increase of white blood cells and neutrophils). therapeutic massage improves the symptoms of children with cancer, but there is a need for more research that may support the effects attributed to it. conocer los efectos del uso del masaje terapéutico en niños con cáncer. revisión sistemática de ensayos clínicos controlados la búsqueda se llevó a cabo en noviembre de 2014 en las bases de datos científicas: Pubmed, CSIC, Dialnet, Scopus, Cochrane y PEDro. Los criterios de inclusión han sido: ensayos clínicos, publicados en inglés o español, en los que se analizaran los efectos del masaje en las diferentes etapas y tipos de cáncer infantil (entre 1 y 18 años). de 1007 artículos localizados, 7 cumplieron los criterios de inclusión. Sus autores utilizan diferentes técnicas de masaje (masaje sueco, effleurage, petrissage, fricciones, presiones), obteniendo beneficios en los síntomas presentes durante la enfermedad (disminución del dolor, náuseas, estrés, ansiedad y aumento de glóbulos blancos y neutrófilos). el masaje terapéutico mejora los síntomas de los niños con cáncer, que respalden los efectos que se le atribuyen. conhecer os efeitos do uso da massagem terapêutica em crianças com câncer. revisão sistemática de ensaios clínicos controlados. A pesquisa foi realizada em novembro de 2014 em bases de dados científicas: Pubmed, CSIC, Dialnet, Scopus, Cochrane and PEDro. Os critérios de inclusão foram: ensaios clínicos, publicados em inglês ou espanhol, analisando os efeitos da massagem nas diferentes fases e tipos de câncer infantil (entre 1 e 18 anos). de 1007 artigos encontrados, 7 preencheram os critérios de inclusão. Os autores utilizam diferentes técnicas de massagem (massagem sueca, effleurage, petrissage, fricções, pressões), obtendo benefícios nos sintomas presentes durante a doença (diminuição da dor, náusea, estresse, ansiedade e aumento de glóbulos brancos e neutrófilos). a massagem terapêutica melhora os sintomas das crianças com câncer, mas são necessárias mais pesquisas que apoiem os efeitos atribuídos a ela.

  13. Accounting for the Impact of Conservation on Human Well-Being

    PubMed Central

    Milner-Gulland, EJ; Mcgregor, JA; Agarwala, M; Atkinson, G; Bevan, P; Clements, T; Daw, T; Homewood, K; Kumpel, N; Lewis, J; Mourato, S; Palmer Fry, B; Redshaw, M; Rowcliffe, JM; Suon, S; Wallace, G; Washington, H; Wilkie, D

    2014-01-01

    Conservationists are increasingly engaging with the concept of human well-being to improve the design and evaluation of their interventions. Since the convening of the influential Sarkozy Commission in 2009, development researchers have been refining conceptualizations and frameworks to understand and measure human well-being and are starting to converge on a common understanding of how best to do this. In conservation, the term human well-being is in widespread use, but there is a need for guidance on operationalizing it to measure the impacts of conservation interventions on people. We present a framework for understanding human well-being, which could be particularly useful in conservation. The framework includes 3 conditions; meeting needs, pursuing goals, and experiencing a satisfactory quality of life. We outline some of the complexities involved in evaluating the well-being effects of conservation interventions, with the understanding that well-being varies between people and over time and with the priorities of the evaluator. Key challenges for research into the well-being impacts of conservation interventions include the need to build up a collection of case studies so as to draw out generalizable lessons; harness the potential of modern technology to support well-being research; and contextualize evaluations of conservation impacts on well-being spatially and temporally within the wider landscape of social change. Pathways through the smog of confusion around the term well-being exist, and existing frameworks such as the Well-being in Developing Countries approach can help conservationists negotiate the challenges of operationalizing the concept. Conservationists have the opportunity to benefit from the recent flurry of research in the development field so as to carry out more nuanced and locally relevant evaluations of the effects of their interventions on human well-being. Consideración del Impacto de la Conservación sobre el Bienestar Humano Resumen Los conservacionistas cada vez más se comprometen con el concepto del bienestar humano para mejorar el diseño y la evaluación de sus intervenciones. Desde la convención de la influyente Comisión Sarkozy en 2009, los investigadores del desarrollo han estado refinando las conceptualizaciones y los marcos de trabajo para entender y medir el bienestar humano y están comenzando a convergir con un entendimiento común de cuál es la mejor forma de hacer esto. En la conservación el término bienestar humano tiene un uso amplio, pero existe la necesidad de la orientación en su operación para medir los impactos de las intervenciones de la conservación sobre la gente. Presentamos un marco de trabajo para entender el bienestar humano que podría ser útil particularmente en la conservación. El marco de trabajo incluye tres condiciones: cumplir con las necesidades, perseguir objetivos y experimentar una calidad satisfactoria de vida. Resumimos algunas de las complejidades involucradas en la evaluación de los efectos del bienestar de las intervenciones de la conservación con el entendimiento de que el bienestar varía entre la gente, en el tiempo y con las prioridades del evaluador. Los retos clave para la investigación de los impactos del bienestar de las intervenciones de la conservación incluyen la necesidad de crear una colección de estudios de caso para trazar lecciones generalizables: hacer uso del potencial de la tecnología moderna para apoyar la investigación del bienestar; y contextualizar espacial y temporalmente las evaluaciones de los impactos de la conservación sobre el bienestar dentro del marco más amplio del cambio social. Existen caminos que atraviesan la confusión que rodea al término bienestar, y los marcos de trabajo existentes, como el del acercamiento de Bienestar en Países en Desarrollo, pueden ayudar a los conservacionistas a negociar los obstáculos de la operación del concepto. Los conservacionistas tienen la oportunidad de beneficiarse del frenesí reciente de investigación en el campo del desarrollo para así realizar evaluaciones más matizadas y relevantes localmente de los efectos de sus intervenciones sobre el bienestar humano. PMID:24641551

  14. El efecto de la panfotocoagulación con láser en edema macular diabético con el fotocoagulador Pascal® versus el láser de argón convencional.

    PubMed

    Mahgoub, Mohamed M; Macky, Tamer A

    2017-07-11

    Objetivo: El objetivo de este estudio fue comparar el efecto de la panfotocoagulación (PFC) en el edema macular diabético (EMD) en pacientes con retinopatía diabética proliferativa (RDP) con el fotocoagulador Pascal® (FP) vs. un fotocoagulador con láser de argón convencional (FLAC). Métodos: Se aleatorizó el uso de FP o FLAC en ochenta ojos con RDP y EMD con afectación central de la mácula. Ambos grupos tuvieron una evaluación de base de mejor agudeza visual corregida y fueron examinados con tomografía de coherencia óptica y angiografía con fluoresceína. Resultados: El número medio de disparos de láser en los grupos de FP y FLAC fue 1.726,10 y 752,00 en la sesión 1 y 1.589,00 y 830,00 (p < 0,001) en la sesión 2, respectivamente. El grosor foveal central (GFC) medio antes de comenzar el estudio fue 306 ± 100 y 314 ± 98 en los grupos de FP y FLAC, respectivamente. A las 8 semanas, el GFC medio fue 332 ± 116 y 347 ± 111 en los grupos de FP y FLAC, respectivamente (p > 0,05). La MAVC media fue similar durante el periodo de estudio y no hubo ninguna diferencia significativa entre los grupos (p > 0,05). Conclusiones: El FP y el FLAC mostraron efectos similares en el EMD en ojos con RDP y fueron igualmente seguros sin un aumento significativo del GFC. © 2017 S. Karger AG, Basel.

  15. A new approach to the study of therapeutic work in the transference.

    PubMed

    Pessier, J; Stuart, J

    2000-02-01

    This article proposes a new method for evaluating the effects of therapist and patient work in the transference. Work in the transference is often difficult for the patient, and may show a characteristic pattern of lag between a transference interpretation and its therapeutic effect. To account for this lag, we assessed patient responses to interpretations over the course of entire sessions. The narratives patients told about others, or Relationship Episodes (REs), were used as units of study. In a sample of three consecutive sessions taken from each of three psychodynamic cases, we identified several instances when transference work appeared to have an initial inhibitory effect, but facilitated progress over the course of the entire session. We recommend that to examine the effects of interpretations future studies use longer, more clinically meaningful segments of patient speech than have been used in the past. Dieser Beitrag propagiert eine neue Methode zur Evaluierung der Effekte von Übertragungsarbeit durch Therapeut und Patient. Arbeit in der Übertragung ist für den Patienten oftmals schwierig und zeigt häufig eine charakteristisches Muster von zeitlichen Verzögerungen bzgl. Übertragungsdeutungen und deren therapeutischen Effekten. Um diese zeitliche Verzögerung zu erklären, untersuchten wir die Reaktionen von Patienten auf derartige Deutungen im Verlauf ganzer Sitzungen. Narrative, in denen die Patienten über andere berichteten, also Beziehungsepisoden, dienten in dieser Studie als Einheit. In einter Stichprobe dreier aufeinanderfolgender Sitzugnen, die sich auf drei Fälle bezogen, identifizierten wir verschiedene Umstände, unter denen Übertragungsarbeit anfänglich einen hemmenden Affekt zu haben schien, letztlich aber den Gesamtverlauf der Sitzung günstig beeinflussten. Wir empfehlen, in Zukunft die Effekte von Übertragungsdeutungen auf der Basis längerer, klinische sinnvoller Segmente von Patientenäußerungen zu untersuchen als dies in der Vergangenheit der Fall war. Cet article propose une nouvelle méthode pour évaluer les effets du travail sur le transfert entre thérapeute et patient. Ce travail est souvent difficile pour le patient, et il peut y avoir un pattern caractéristique de délai entre une înterprétation de transfert et son effet thérapeutique. Pour expliquer ce délai, nous avons évalué les réponses des patients à des interprétatios au cours de séances entières. C'est les narrations des patients sur d'autres, ou Episodes Relationnels (ERs), qui ont constitué les unités de base de cette étude. Dans un échantillon de 3 séances consécutives venant de 3 cas psychodynamiques, nous avons identifié plusieurs moments où le traail sur le transfert semblait avoir un effet inhibitoire initial, mais favorisait le progrès en regardant la séance entière. Nous recommandons pour de futures études sur l'effet des interprétations de prendre des segments plus longs et cliniquement significatifs du récit du patient que ceux utilisés dans le passé. Este artículo propone un nuevo método para evaluar los efectos del trabajo de terapeuta y paciente en la transferencia. El trabajo en la transferencia es, con frecuencia, dificil para el paciente y puede mostrar un lapso característico entre una interpretación transferencial y sus efectos terapéuticos. Para explicar este lapso, hemos evaluado las respuestas del paciente a las interpretaciones a lo largo de sesiones enteras. Como unidad de estudio se usaron las narrativas de los pacientes acerca de otros, o sea, los episodios relacionales (REs). En una muestra de tres sesiones consecutivas tomadas de tres casos psicodinámicos, identificamos varioss casos en los que la trasferencia parecía tener un efecto inicial inhibitorio, aunque se vio que a lo largo de la sesión facilitaba el progreso. Recomendamos que, para examinar los efectos de las interpretaciones, los futuros estudios usen segmentos más largos y clínicamente más significativos del habia del paciente que los que se usaron en el pasado.

  16. Generacion de Nuevas Capacidades en el Ejercito de Guatemala para el Combate al Trafico de Drogas y Delitos Conexos (Generating New Capacities within the Guatemalan Army in Order to Combat Drug Trafficking and Related Crimes)

    DTIC Science & Technology

    2014-06-13

    la pérdida de control territorial por parte del Estado en el tema de seguridad y la poca credibilidad que la sociedad tiene en sus fuerzas...de seguridad civil y segundo: como efecto no buscado de la presión ejercida por el gobierno de Colombia y el de México en alianza con los Estados...naturales y líneas rectas que unen detalles topográficos fijados y descritos en el mismo Laudo. Para la defensa de la seguridad nacional, el Ejército

  17. Efecto de la difusión y la velocidad en la ionización del átomo de Carbono

    NASA Astrophysics Data System (ADS)

    Rovira, M. G.; Fontenla, J. M.

    The equations of statistical equilibrium for all ionization states of the atom are solved. The effects of diffusion and center of mass velocity are included. In order to estimate the modifications of the ionization curves, they were applied to the Carbon atom. To solve these equations, solar prominences' models obtained in a previous paper were adopted. They were extended to reach a temperature of 1.5 × 106 K and the complete model of the prominence was calculated. Ionization curves for different values of velocity, diffusion and medium models were obtained. The different models represent structures with different densities. Considerable modifications due to these effects are found.

  18. Efecto del gas nebular sobre la dinámica de un protoplaneta Joviano

    NASA Astrophysics Data System (ADS)

    Cionco, R. G.; Brunini, A.

    In order to describe a realist scenario to investigate the formation of giant planets, we analyze the physical structure of the primordial gaseous circumsolar disk, the environment where protoplanets growth. We calculate the gas drag efect onto embrios of 1 M⊕ at 5.2 AU with a new formulation of the dinamycal friction effect. We have found a strong radial migration of the protoplanet, that, in comparison whith the predictions of other formulations of gas drag is, at least, one order of magnitude larger. This result casts doubts about the possible survival of these kinds of planetary embrios. The implications for the modelling of the planetary systems are discussed.

  19. Estudio fenomenologico del conocimiento curricular y conocimiento de contenido en maestros de matematica a nivel secundario

    NASA Astrophysics Data System (ADS)

    Cardona Tomassini, Ivan Javier

    En esta investigacion se estudio el fenomeno del conocimiento de contenido y el conocimiento curricular de maestros de matermaticas y como estos dos componentes se reflejan en su conocimiento pedagogico del contenido. El conocimiento de contenido es el conocimiento que tienen los maestros de los contenidos de una disciplina y sobre la estructura de su organizacion (Shulman, 1986). El conocimiento curricular es el conocimiento que los maestros poseen sobre los componentes de un curriculo disenado para ensenar un topico de una materia especifica a un nivel particular, la variedad de instrumentos instruccionales disponibles para implementar el mismo y como utilizar los instrumentos curriculares disponibles (Ball & Bass, 2003; Choppin, 2009; Hill, Rowan, & Ball, 2005). Este estudio se enmarca en el paradigma cualitativo, teniendo como diseno el estudio fenomenologico (Lucca y Berrios, 2009; McMillan, 2004). Los participantes fueron seis maestros de matermaticas del nivel superior (10mo a 12mo grado). Al momento de la investigacion los participantes ensenaban en escuelas publicas o privadas de Puerto Rico. Para recolectar la informacion se utilizo un grupo focal en donde los maestros resolvieron seis ejercicios matematicos y posteriormente reflexionaron en forma grupal sobre las soluciones. Tambien se realizo un analisis de documentos de planificacion y se llevaron a cabo entrevistas semiestructuradas. Se exploraron los contenidos relacionados a la ecuacion de una recta, rectas verticales y horizontales, suma y multiplicacion de polinomios, resolucion de ecuaciones cuadraticas y distancia entre dos puntos del plano cartesiano. Los resultados muestran que los participantes tienen dominio procesal de los contenidos correspondientes a las rectas verticales y horizontales, la suma y multiplicacion de polinomios, el calculo distancia entre dos puntos del plano cartesiano. Sin embargo, se noto cierta dificultad en la explicacion conceptual de los contenidos relacionados a la ecuacion de la recta, las rectas verticales y horizontales y la solucion de ecuaciones cuadraticas. Lo cual permite concluir que los participantes demuestran mejor dominio del conocimiento procesal que del conocimiento conceptual. Estos es un reflejo del efecto de una instruccion enfocada en desarrollar los procesos algoritmicos ya que la explicacion con sentido de los procesos pasa a un segundo plano.

  20. Morfología de la Coma del Cometa Hale - Bopp

    NASA Astrophysics Data System (ADS)

    Gil-Hutton, R.; Caballero, M.; Coldwell, G.; Cañada, M.; Godoy, G.; Trozzo, C.; Gómez, G.

    Para lograr comprender plenamente los procesos físicos que se desarrollan en los núcleos cometarios y obtener un modelo que explique, no sólo su actividad, sino también sus efectos sobre la coma, es necesario obtener información detallada para el mayor número de cometas posible, siendo las características más interesantes para estudiar la ubicación de las regiones activas, la presencia de jets, las tasas de producción de gas y polvo y la interacción de la coma con el viento solar. En la actualidad, con técnicas de procesamiento de imágenes y tecnología CCD se pueden obtener este tipo de datos para cometas que ingresan al sistema solar interior y estudiar, de esta manera, la morfología de sus comas, tratando de correlacionar la actividad detectada con algún modelo teórico. En este trabajo se presenta un estudio parcial de la actividad desarrollada por el cometa Hale-Bopp, y sus efectos sobre la morfología de su coma, desde agosto de 1995 hasta la fecha en base a imágenes adquiridas con el telescopio de 0.76 m. de la Estación Astronómica Dr. Carlos Ulrrico Cesco.

  1. Evolución Dinámica de Cúmulos Estelares Abiertos

    NASA Astrophysics Data System (ADS)

    de La Fuente Marcos, R.

    Las estrellas que observamos no se formaron aisladamente, sino que lo hicieron en grupos o cúmulos. Estos sistemas estelares recibenel nombre de cúmulos estelares abiertos o galácticos cuando están constituidos por estrellas de la Población I. Los cúmulos abiertos se localizan preferentemente en el plano galáctico, y en muchos de ellos está teniendo lugar aún una activa formación estelar. El propósito principal de esta tesis doctoral es el estudio de la evolución dinámica de estos sistemas estelares por medio de simulaciones numéricas y de la comparación de sus resultados con datos observacionales. Con este fin se analizan los efectos que, sobre la dinámica de los cúmulos, ejercen varios fenómenos de interés astrofísico tales como el campo gravitatorio galáctico, la pérdida de masa causada por la evolución estelar y la presencia de binarias primordiales. En este trabajo se presentan los resultados de más de un centenar de modelos de cúmulos, con poblaciones comprendidas en el intervalo [100, 10.000] estrellas, calculados con NBODY5, un programa estándar en el campo de la Dinámica Estelar Experimental. De los mismos se deduce que el mecanismo principal que rige la dinámica de los cúmulos abiertos es la evolución estelar de su distribución de masas, encontrándose un comportamiento diferencial fuertemente dependiente de la población inicial del cúmulo. Los mecanismos responsables de la desintegración de los cúmulos abiertos son analizados en detalle, proponiéndose un modelo analítico que ajusta razonablemente los resultados de las simulaciones. Además, y con el fin de explicar el elevado número de sistemas múltiples observados en cúmulos abiertos, se estudian los efectos que, sobre los mismos, ejerce la presencia de una cierta fracción de binarias primordiales. El papel de las binarias tambiín depende de la riqueza del cúmulo y sus efectos se interrelacionan con aquellos debidos a la evolución estelar. Por último, se aborda la posibilidad de construir diagramas de Hertzsprung-Russell teóricos a partir de las simulaciones y compararlos con datos procedentes de cúmulos abiertos reales.

  2. Modelo analítico del efecto de PRS sobre satélites GPS

    NASA Astrophysics Data System (ADS)

    Meza, A.; Brunini, C.; Usandivaras, J. C.

    El sistema GPS (Global Position System) es, hoy en día, la herramienta de navegación y posicionamiento más potente y lo será sin duda en la próxima década. Gran parte de su valiosa utilidad se debe a la alta precisión que permite lograr y ésta, a su vez, depende, entre otras causas, de la precisión con que se conocen las órbitas de los satélites. La presión de radiación solar (PRS) fija el límite de la precisión con que pueden calcularse en la actualidad las efemérides satelitarias. El objetivo de este trabajo es proponer una mejor resolución de este fenómeno. El modelo analítico aquí presentado, se basa en el análisis del comportamiento de los residuos de un ajuste por mínimos cuadrados en el que se utiliza el modelo de PRS propuesto por Beutler. El mismo consiste en un modelo determinista del fenómeno con dos parámetros libres. Los resultados obtenidos ponen de manifiesto que, aún después de aplicar dichos parámetros, prevalecen en los residuos efectos semidiurnos en las componentes radial,tangencial y normal. Estos resultados obtenidos se comparan con los de un trabajo desarrollado por el Instituto de Berne (Beutler et al., 1994), en el que se utilizaron como pseudo-observaciones las órbitas precisas del IGS (CODE). El intervalo de integración escogido por este centro fueron las semanas 680 y 681. En resumen se tienen arcos de 14 días para todos los satélites, donde las efemérides precisas de los mismos para los 14 días fueron utilizados como pseudo-observaciones. El modelo de fuerza que empleó dicho centro fue básicamente el tradicional en lo que respecta al modelo de las fuerzas gravitacionales, y para la PRS utilizo el modelo standard de Beutler. Los parámetros de este modelo junto con las 6 condiciones iniciales (posición y velocidad) fueron ajustados por el método general de mínimos cuadrados. Los residuos en la componente radial, tangencial y normal, para los satélites con un buen comportamiento, presentan una componente semidiurna. El modelo analítico planteado en este trabajo, predice el comportamiento de los residuos que se observan en las publicaciones más recientes. Esto abre el camino para plantear una estimación distinta de las incógnitas del problema, basado en el método de colocación por mínimos cuadrados. Ello requiere modelar estadísticamente la señal debida a las componentes de la PRS que no son tomadas en cuenta en el modelo determinista.

  3. Modality effect in false recognition: evidence from Chinese characters.

    PubMed

    Mao, Wei Bin; Yang, Zhi Liang; Wang, Lin Song

    2010-02-01

    Using the Deese/Roediger-McDermott (DRM) false memory method, Smith and Hunt ( 1998 ) first reported the modality effect on false memory and showed that false recall from DRM lists was lower following visual study than following auditory study, which led to numerous studies on the mechanism of modality effect on false memory and provided many competing explanations. In the present experiment, the authors tested the modality effect in false recognition by using a blocked presentation condition and a random presentation condition. The present experiment found a modality effect different from the results of the previous research; namely, false recognition was shown to be greater following visual study than following auditory study, especially in the blocked presentation condition rather than in the random presentation condition. The authors argued that this reversed modality effect may be due to different encoding and processing characteristics between Chinese characters and English words. Compared with English words, visual graphemes of critical lures in Chinese lists are likely to be activated and encoded in participants' minds, thus it is more difficult for participants to discriminate later inner graphemes from those items presented in visual modality. Hence visual presentation could lead to more false recognition than auditory presentation in Chinese lists. The results in the present experiment demonstrated that semantic activation occurring during the encoding and retrieve phases played an important role in modality effect in false recognition, and our findings might be explained by the activation-monitoring account. Utilisant la méthode de fausse mémoire de Deese/Roediger-McDermott (DRM), Smith et Hunt ( 1998 ) ont d'abord rendu compte de l'effet de modalité sur la fausse mémoire et ils ont montré que le faux rappel à partir des listes de DRM était plus faible suivant une étude visuelle plutôt qu'une étude auditive. Ceci a mené à plusieurs études sur le mécanisme de l'effet de modalité sur la fausse mémoire, lesquelles ont fourni plusieurs explications concurrentes. Dans la présente expérience, les auteurs ont testé l'effet de modalité dans la fausse reconnaissance en utilisant une condition de présentation fixe et une condition de présentation aléatoire. Cette expérience a révélé un effet de modalité différent des résultats obtenus dans les recherches antérieures. En effet, la fausse reconnaissance était plus élevée suivant une étude visuelle plutôt qu'une étude auditive, spécialement dans la condition de présentation fixe. Les auteurs suggèrent que cet effet de modalité inverse peut être dû à des caractéristiques d'encodage et de processus différentes entre les caractères chinois et les mots anglais. Comparativement aux mots anglais, les graphèmes visuels des leurres critiques dans les listes chinoises sont susceptibles d'être activés et encodés dans l'esprit des participants, rendant plus difficile de discriminer les graphèmes intériorisés plus tard de ces items présentés dans la modalité visuelle. Ainsi, la présentation visuelle pourrait mener à davantage de fausse reconnaissance que la présentation auditive dans les listes chinoises. Les résultats de la présente expérience ont démontré que l'activation sémantique se produisait durant l'encodage et que la phase de retrait jouait un rôle important dans l'effet de modalité dans la fausse reconnaissance. Nos résultats peuvent être expliqués par la théorie activation-contrôle. Utilizando el método de Deese/Roediger-McDermott (DRM) de falsa mamoria, Smith y Hunt ( 1998 ) fueron los primeros en encontrar el efecto de modalidad en la falsa memoria y demostraron que los falsos recuerdos del listado DRM fueron más bajos después de un estudio visual que después de un estudio auditivo lo cual llevó a varios estudios sobre el mecanismo del efecto de la modalidad sobre falsos recuerdos y proporcionó varias explicaciones que compiten entre sí. En el presente trabajo, los autores estudiaron el efecto de la modalidad en el falso reconocimiento utilizando una condición de presentación en bloques y otra condición de presentación de forma aleatoria. El presente experimento encontró un efecto de la modalidad diferente de los resultados de los estudios anteriores. En concreto, el reconocimiento falso ha resultado ser mayor después del estudio visual que después del estudio auditivo, especialmente en caso de la presentación en bloques en comparación con la condición de presentación aleatoria. Los autores argumentan que este efecto inverso de la modalidad puede ser causado por diferentes características de codificación y procesamiento entre caracteres chinos y palabras inglesas. En comparación con las palabras inglesas, los grafemas visuales de las palabras críticas en chino tienen probabilidad de ser activadas y codificadas en las mentes de los participantes, por tanto, es más difícil discriminar posteriores grafemas internos de los que fueron presentados en la modalidad visual. Por tanto, la presentación visual podría conducir a más falsos reconocimientos que la presentación auditiva en los listados de palabras chinas. Los resultados del presente experimento demostraron que la activación semántica durante las fases de codificación y recuperación jugó un rol importante en el efecto de falso reconocimiento según modalidad y que nuestros resultados se pueden explicar teniendo en cuenta la activación y la vigilancia.

  4. Satisfaction with medication in coronary disease treatment: psychometrics of the Treatment Satisfaction Questionnaire for Medication.

    PubMed

    Liberato, Ana Carolina Sauer; Rodrigues, Roberta Cunha Matheus; São-João, Thaís Moreira; Alexandre, Neusa Maria Costa; Gallani, Maria Cecília Bueno Jayme

    2016-06-07

    to psychometrically test the Brazilian version of the Treatment Satisfaction Questionnaire for Medication - TSQM (version 1.4), regarding ceiling and floor effect, practicability, acceptability, reliability and validity. participants with coronary heart disease (n=190) were recruited from an outpatient cardiology clinic at a university hospital in Southeastern Brazil and interviewed to evaluate their satisfaction with medication using the TSQM (version 1.4) and adherence using the Morisky Self-Reported Measure of Medication Adherence Scale and proportion of adherence. The Ceiling and Floor effect were analyzed considering the 15% worst and best possible TSQM scores; Practicability was assessed by time spent during TSQM interviews; Acceptability by proportion of unanswered items and participants who answered all items; Reliability through the Cronbach's alpha coefficient and Validity through the convergent construct validity between the TSQM and the adherence measures. TSQM was easily applied. Ceiling effect was found in the side effects domain and floor effect in the side effects and global satisfaction domains. Evidence of reliability was close to satisfied in all domains. The convergent construct validity was partially supported. the Brazilian TSQM presents evidence of acceptability and practicability, although its validity was weakly supported and adequate internal consistency was observed for one domain. realizar o teste psicométrico da versão brasileira do Treatment Satisfaction Questionnaire for Medication - TSQM (versão 1.4) [Questionário Satisfação com Tratamento Medicamentoso] com relação aos efeitos de teto e chão, praticidade, aceitabilidade, confiabilidade e validade. os participantes com doença cardíaca coronária (n=190) foram recrutados num ambulatório de cardiologia de um hospital universitário no sudeste do Brasil e entrevistados para avaliar satisfação em relação ao tratamento medicamentoso através da TSQM (versão 1.4) e adesão através da Morisky Self-Reported Measure of Medication Adherence Scale [Medida de Auto-Relato de Adesão ao Tratamento Medicamentoso] e proporção de aderência. Os efeitos Teto e Chão foram analisados considerando os 15% piores e 15% melhores escores possíveis obtidos no TSQM; Praticidade foi avaliada pelo tempo gasto na aplicação do TSQM durante a entrevista; Aceitabilidade foi verificada pela proporção de itens não respondidos e participantes que responderam todos os itens; Confiabilidade foi verificada com o coeficiente alfa de Cronbach e Validade através da validade de construto convergente entre o TSQM e as medidas de adesão. o TSQM foi facilmente aplicado. O efeito teto foi encontrado no domínio efeitos colaterais e o efeito chão foi encontrado nos domínios efeitos colaterais e satisfação global. Evidência de confiabilidade foi próxima de satisfatória em todos os domínios. A validade de construto convergente foi parcialmente apoiada. a versão brasileira do TSQM apresenta evidência de aceitabilidade e praticidade embora sua validade tenha sido pouco apoiada e consistência interna adequada foi observada em um domínio. testar las propiedades psicométricas de la versión brasileña del Treatment Satisfaction Questionnaire for Medication - TSQM (versión 1.4), considerando los efectos techo y suelo, factibilidad, aceptabilidad, confiabilidad y validez. participantes con enfermedad coronaria (n=190) fueron reclutados de una clínica ambulatoria de cardiología en un hospital universitario en el sudeste de Brasil y entrevistados para evaluar su satisfacción con la medicación con el TSQM (versión 1.4) y su adhesión con la Morisky Self-Reported Measure of Medication Adherence Scale y proporción de adhesión. Los efectos techo y suelo fueron analizados considerando los 15% peores y mejores puntuaciones en el TSQM; la factibilidad fue evaluada por el tiempo gasto durante las entrevistas de TSQM; la aceptabilidad por la proporción de ítems no respondidos y participantes que contestaron a todos los ítems; la confiabilidad con el coeficiente alfa de Cronbach y la validez de constructo convergente entre el TSQM y las medidas de adhesión. el TSQM fue aplicado con facilidad. El efecto de techo fue encontrado en el dominio de los efectos secundarios y el efecto suelo en los dominios de efectos secundarios y satisfacción global. Las evidencias de confiabilidad fueron aproximadamente satisfechas en todos los dominios. La validez de constructo convergente fue parcialmente apoyada. la versión brasileña del TSQM presenta evidencias de aceptabilidad y factibilidad, a pesar del soporte débil a su validez y de la observación de consistencia interna adecuada para un dominio.

  5. Salud mental en desastres naturales: estrategias interventivas con adultos mayores en sectores rurales de Chile.

    PubMed

    Osorio-Parraguez, Paulina; Espinoza, Adriana

    2016-06-01

    En el presente artículo se da a conocer una estrategia de intervención llevada a cabo con adultos mayores en la comuna de Paredones, sexta región de Chile, con posterioridad al terremoto y tsunami del 27 de febrero 2010 en Chile, en el contexto de una investigación sobre fortalezas y vulnerabilidades desplegadas por este grupo etario, con posterioridad a un desastre natural. Se presenta una descripción del desarrollo metodológico de la intervención y de los sustentos teóricos y conceptuales en los que se basa. Como resultado de este proceso, se propone una estrategia que trabaje a través de la identificación de las propias experiencias y fortalezas de los sujetos. De tal forma se minimizan los efectos negativos de los determinantes sociales de la salud (como la edad y el lugar de residencia) en contexto de crisis; permitiendo a los adultos mayores fortalecer sus recursos individuales y colectivos, en pro de su bienestar psicosocial. © The Author(s) 2015.

  6. Expresiones de afecto de madres bilingües, Bilingual mothers' expressions of affect

    PubMed Central

    Shiro, Martha

    2015-01-01

    En la interacción de 10 madres bilingües con sus hijos de 30 meses se analiza la expresión de afectividad en L1 y en L2. Se identificaron las expresiones de emoción, volición y actitud epistémica en 30 interacciones espontáneas: i. 10 madres (español L1) hablando en L1; ii. 10 madres (español L1) hablando en inglés L2; y iii. 10 madres (inglés L1) hablando en L1. Los resultados sugieren que los usos de L2 difieren de los de L1 (inglés o español): la expresión de volición y actitud epistémica se asemeja al inglés L1, mientras que la expresión de las emociones se acerca al español L1. Estos hallazgos permiten explicar los usos del lenguaje expresivo de los bilingües y ayudan a determinar sus efectos en el desarrollo del lenguaje PMID:25844004

  7. [Reconstrucción ósea de defectos craneales secundarios a traumatismo con implantes personalizados].

    PubMed

    Cienfuegos, Ricardo; Fernández, Gerardo; Cruz, Aída; Sierra, Eduardo

    2018-01-01

    Los defectos craneales secundarios a traumatismos son frecuentes. Por lo común se reparan de forma secundaria por sintomatología como el síndrome del paciente trepanado, por protección cerebral y por el aspecto cosmético. Históricamente se han utilizado diversos materiales para la reconstrucción. Se presentan cinco casos de pacientes reconstruidos con implantes personalizados de polieteretercetona (PEEK) o polimetilmetacrilato poroso (PMMA). Las localizaciones afectaron el frontal, el borde orbitario superior y el techo orbitario en cuatro casos, y la porción lateral del frontal, la zona temporoparietal y el borde del occipital en un caso. La reconstrucción en cuatro pacientes fue entre 6 y 12 meses después de la lesión, y en un caso después de 25 años. En dos casos se requirió expansión tisular antes de colocar el implante. Cuatro pacientes evolucionaron favorablemente, con mejoría de los síntomas neurológicos, forma y contorno adecuados, así como un proceso de cicatrización adecuada de los colgajos de piel cabelluda. Un paciente presentó infección por Staphylococcus aureus, atribuida a la presencia de un mucocele y una fístula de la vía aérea a la cavidad craneal, lo que hizo necesario retirar el implante. Los implantes personalizados son un recurso útil para defectos óseos craneales. Brindan resultados satisfactorios desde el punto de vista funcional y cosmético. Deben tomarse precauciones respecto al tratamiento de las lesiones que afecten el seno frontal, para evitar la comunicación entre la vía aérea y la cavidad craneal. Cranial defects due to trauma are frequent. They are usually repaired in a secondary fashion due to features such as syndrome of the trephined, for brain protection and for cosmetic purposes. Historically, various materials have been used for reconstruction. Five cases of patients reconstructed with customized polyetheretherketone (PEEK) o polymethyl methacrylate (PMMA) implants are presented. Defects involved the frontal bone, superior orbital rim and orbital roof in four cases, and the lateral area of the frontal bone, the temporoparietal area and the border of the occipital bone in one. In four patients, reconstruction took place between 6 and 12 months after the injury; in one patient, after 25 years. Two cases required tissue expansion before placing the implant. Four patients evolved favorably, with improvement in neurologic symptoms and adequate shape and contour, plus adequate healing of the scalp flaps. One patient had an infection due to Staphylococcus aureus, attributed to a mucocele and fistula between the airway and the cranial cavity, leading to removal of the implant. Customized implants are a useful resource for cranial defects. They offer satisfactory results, both functional and cosmetic. Precautions should be taken in treating injuries that involve the frontal sinus, to ensure there is no communication between the airway and the cranial cavity. Copyright: © 2018 SecretarÍa de Salud.

  8. Nuevos fenómenos en erupciones cometarias

    NASA Astrophysics Data System (ADS)

    Silva, A.

    Se discuten aquí tres procesos físicos novedosos encontrados en la actividad de cometas: 1) El rol de una distribución de granos de hielo como fuente extendida de H2O en la coma, 2) El efecto de una discontinuidad en el plasma cometario, llamada Cometopausa, sobre la excitación del radical OH , y 3) La actividad por erupciones a grandes distancias heliocéntricas (r > 5 AU). Con respecto a 1) y 2), se presentan modelos que ajustan bien con las observaciones. En cuanto a 3), se presentan explicaciones posibles al fenómeno, y se trata el interesante caso de Chirón 2060, basándose en observaciones propias tomadas desde el CASLEO y datos anteriores.

  9. Peligros de deslizamientos [Landslide Hazards

    USGS Publications Warehouse

    ,

    2000-01-01

    Deslizamientos, flujos de escombrera y desastres geológicos similares provenientes de volcanes ocurren alrededor del mundo. Cada año estos desastres causan billones de dólares en pérdidas y un sinnúmero de fatalidades y heridos. El primer paso para reducir los efectos dañinos causados por estos desastres es el conocimiento y educación acerca de ellos. El Servicio Geológico de los Estados Unidos se dedica a educar una gran cantidad de personas a través de información e investigaciones acerca de peligros geológicos. Este documento está publicado en inglés y español y puede ser reproducido de cualquier forma para fomentar su distribución.

  10. A systematic review and meta-analysis on the longitudinal relationship between eating pathology and depression.

    PubMed

    Puccio, Francis; Fuller-Tyszkiewicz, Matthew; Ong, Deborah; Krug, Isabel

    2016-05-01

    Undertake a meta-analysis to provide a quantitative synthesis of longitudinal studies that assessed the direction of effects between eating pathology and depression. A second aim was to use meta-regression to account for heterogeneity in terms of study-level effect modifiers. A systematic review was conducted on 42 studies that assessed the longitudinal relationship between eating pathology and depression. Of these 42 studies, multilevel random-effects meta-analyses were conducted on 30 eligible studies. Meta-analysis results showed that eating pathology was a risk factor for depression (rm  = 0.13) and that depression was a risk factor for eating pathology (rm  = 0.16). Meta-regression analyses showed that these effects were significantly stronger for studies that operationalized eating pathology as an eating disorder diagnosis versus eating pathology symptoms, and for studies that operationalized the respective outcome measure as a categorical variable (e.g., a diagnosis of a disorder or where symptoms were "present"/"absent") versus a continuous measure. Results also showed that in relation to eating pathology type, the effect of an eating disorder diagnosis and bulimic symptoms on depression was significantly stronger for younger participants. Eating pathology and depression are concurrent risk factors for each other, suggesting that future research would benefit from identifying factors that are etiological to the development of both constructs. Llevar a cabo un meta-análisis para proporcionar una síntesis cuantitativa de los estudios longitudinales que evaluaron la dirección de los efectos entre la alimentación patológica y la depresión. Un segundo objetivo fue utilizar la meta-regresión para dar cuenta de la heterogeneidad en términos de modificadores del efecto a nivel de estudio. MÉTODO: Una revisión sistemática se llevó a cabo en 42 estudios que evaluaron la relación longitudinal entre la alimentación patológica y la depresión. De estos 42 estudios, se realizaron meta-análisis de multinivel de efectos aleatorios en 30 estudios elegibles. Los resultados del meta-análisis mostraron que la alimentación patológica era un factor de riesgo para depresión (rm=0.13) y que la depresión era un factor de riesgo para la alimentación patológica (rm=0.16). Los análisis de meta-regresión mostraron que estos efectos eran significativamente más fuertes para estudios que operacionalizaban la alimentación patológica como un diagnóstico de trastorno de la conducta alimentaria versus síntomas de alimentación patológica, y para los estudios que operacionalizaban la medida respectiva de resultado como una variable categórica (e.g., un diagnóstico de trastorno o cuando los síntomas estaban "presentes"/"ausentes") versus una medida continua. Los resultados mostraron que en relación al tipo de alimentación patológica, el efecto de un diagnóstico de trastorno de la conducta alimentaria y síntomas bulímicos en la depresión era significativamente más fuerte para participantes más jóvenes. DISCUSIÓN: La alimentación patológica y la depresión son factores de riesgo concurrentes uno para el otro, lo que sugiere que la investigación futura se beneficiaría de identificar factores que son etiológicos al desarrollo de ambos constructos. © 2015 Wiley Periodicals, Inc. (Int J Eat Disord 2016;49:439-454). © 2015 Wiley Periodicals, Inc.

  11. [Anaesthetic management in left ventricular assist device implantation as destination therapy: Our first experience].

    PubMed

    del Barrio Gómez, E; Rodríguez, J M; Martínez, S; García, E; Vargas, M C; Sastre, J A

    2016-03-01

    Left ventricular assist devices have emerged as one of the main therapies of advanced cardiac failure due the increase of this disease and lack of organ supply for cardiac transplantation. The anaesthetic management is described on a patient without cardiac transplantation criteria. The device was successfully implanted as a destination therapy. Copyright © 2015 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  12. Bases para la elaboracion de unidades didacticas de calidad en el area de ciencias (Fisica y Quimica 3 deg ESO)

    NASA Astrophysics Data System (ADS)

    Maccioni, Elena Lucia

    Este Trabajo Fin de Master tiene como objeto, el estudio previo de la educacion de la ciencia en la actualidad y mas destacable, del diseno de las unidades didacticas segun las metodologias mas frecuentes aplicadas por los diferentes sistemas educativos en el area de las Ciencias teniendo en cuenta la importancia y el efecto de la psicologia del alumnado y todo ello como no puede ser de otro modo bajo el corse de la Legislacion aplicable, Estatal, Autonomica y europea. Con estos antecedentes, se extrae cuales son las preguntas que deben contestarse en la elaboracion de una unidad didactica de calidad en el contexto, generacional (edad y sexo), del Proyecto Educativo de Centro, y de la Programacion del Departamento, discutiendo y justificando cada uno de los apartados en que estructuradamente dividiremos dicha Unidad, con un formato manejable, util, y dinamico en el tiempo que sea un verdadero instrumento educativo de aula. Teniendo en cuenta estas premisas, se procede a hacer una recopilacion de una misma unidad didactica publicada por diferentes editoriales, elegidas no al azar, sino en funcion de su penetracion editorial en nuestros centros de ESO, siendo las elegidas (SM y Oxford). Las diferentes unidades seleccionadas son analizadas de forma critica, atendiendo a los criterios generales de calidad bajo parametros cientificos y normativos, concluyendo con la aportacion final que es la redaccion de unas pautas cientifico-pedagogicas, para redactar unidades didacticas de calidad en el area de la Ciencias, en concreto en la Asignatura de Fisica y Quimica de 3º de ESO.

  13. Comportamiento dinámico de asteroides en la región 23 < a < 26 UA

    NASA Astrophysics Data System (ADS)

    López García, F.

    Los Kuiper Belt Objects (KBOs) pueden ser una fuente de origen de los cometas de corto período. Muchos de los KBOs observados parecen provenir, al igual que el sistema Pluton-Charonte, de órbitas resonantes con Neptuno. Los Centauros son objetos que dinámicamente provienen de órbitas inestables cuyo semieje mayor se encuentra entre las órbitas de Júpiter y Neptuno. Pudiera ser que estos cuerpos fueron expulsados desde la región del cinturón de Kuiper y se encuentran en un proceso de ``scattering" debido a los efectos gravitacionales de los planetas gigantes. Su tiempo de vida dinámico es de algunos millones de años. La evolución orbital de los objetos trans-Neptunianos nos permite conocer su comportamiento anterior, por eso, es importante su relación dinámica con la evolución orbital de Neptuno. El objeto de este trabajo es estudiar el comportamiento dinámico de partículas test que se encuentran entre las resonancias 3:2 con Neptuno y 2:3 con Urano, las cuales comprenden una región de 2 UA aproximadamente. Los primeros resultados indican que la mayoría de los objetos ficticios son eyectados hacia la parte externa del Sistema Solar, mientras que sólo una parte pequeña del total de objetos estudiados, aproximadamente un 7%, son eyectados hacia la parte interna del Sistema Solar, y en algunos casos sus órbitas pueden cruzar la órbita de los planetas terrestres.

  14. PubMed

    Gómez, Luis Alberto; Montoya, Gladis; Rivera, Hernán Mauricio; Hernández, Juan Carlos

    2017-04-01

    Introducción. El virus del Zika (ZIKV) es un flavivirus con envoltura, transmitido a los seres humanos principalmente por el vector Aedes aegypti. La infección por ZIKV se ha asociado con un gran neurotropismo y con efectos neuropáticos, como el síndrome de Guillain-Barré en el adulto y la microcefalia fetal y posnatal, así como con un síndrome de infección congénita similar al producido por el virus de la rubéola (RV).Objetivo. Comparar las estructuras moleculares de la proteína de envoltura E del virus del Zika (E-ZIKV) y de la E1 del virus de la rubéola (E1-RV), y plantear posibles implicaciones en el neurotropismo y en las alteraciones del sistema nervioso asociadas con el ZIKV.Materiales y métodos. La secuencia de aminoácidos de la proteína E-ZIKV (PDB: 5iZ7) se alineó con la de la glucopreteína E1 del virus de la rubéola (PDB: 4ADG). Los elementos de la estructura secundaria se determinaron usando los programas Vector NTI Advance®, DSSP y POSA, así como herramientas de gestión de datos (AlignX®). Uno de los criterios principales de comparación y alineación fue la asignación de residuos estructuralmente equivalentes, con más de 70 % de identidad.Resultados. La organización estructural de la proteína E-ZIKV (PDB: 5iZ7) fue similar a la de E1-RV (PDB: 4ADG) (70 a 80 % de identidad), y se observó una correspondencia con la estructura definida para las glucoproteínas de fusión de membrana de clase II de los virus con envoltura. E-ZIKV y E1-RV exhibieron elementos estructurales de fusión muy conservados en la región distal del dominio II, asociados con la unión a los receptores celulares de entrada del virus de la rubéola (glucoproteína de mielina del oligodendrocito, Myelin Oligodendrocyte Glycoprotein, MOG), y con los receptores celulares Axl del ZIKV y de otros flavivirus.Conclusión. La comparación de las proteínas E-ZIKV y E1-RV es un paso necesario hacia la definición de otros factores moleculares determinantes del neurotropismo y la patogenia del ZIKV, el cual puede contribuir a generar estrategias de diagnóstico, prevención y tratamiento de las complicaciones neurológicas inducidas por el ZIKV.

  15. Analisis experimental de la propagacion en redes de area corporal para la banda de ultra wideband. experimental characterization of the propagation in ultra wideband body area networks

    NASA Astrophysics Data System (ADS)

    Garcia Serna, Ruben Gregorio

    Diferentes dispositivos capaces de obtener informacion sobre parametros fisiologicos, cinematicos o contextuales del cuerpo pueden interconectarse de manera inalambrica dando lugar a las denominadas Redes de Area Corporal Inalambricas (WBAN, Wireless Body Area Networks). De entre las posibles tecnologias para establecer los enlaces, Ultra Wideband (UWB) esta captando cada vez un mayor interes debido a caracteristicas tales como el bajo nivel de potencia de transmision requerido (bajo nivel de exposicion a campos electromagneticos), el alto ancho de banda disponible y la alta resolucion temporal/espacial. El diseno de sistemas centrados en el cuerpo requiere de modelos de canal que describan de manera precisa la propagacion de senales en este tipo de entornos. Esta tesis se plantea con el objetivo de contribuir al estudio experimental de la propagacion en sistemas centrados en el cuerpo operando en la banda UWB. En primer lugar, se presenta un marco introductorio a las redes WBAN, sus elementos constitutivos, bandas de frecuencia, estandarizacion y modelos de canal. Ademas, se introducen los fundamentos de la tecnologia UWB y sus aplicaciones en este area. Seguidamente, se analiza en terminos de las perdidas de propagacion y la dispersion de retardo la propagacion en el canal off-body entre un transmisor fijo y un dispositivo receptor colocado sobre la superficie del cuerpo de un sujeto. Se considera la influencia de diferentes aspectos, tales como el entorno de medidas, la posicion de colocacion de una antena sobre el cuerpo y la postura adoptada por un sujeto. Finalmente, se analiza el canal de propagacion in-body considerando el movimiento relativo entre dos dispositivos causado por efecto de la respiracion. Las condiciones de propagacion en el interior del cuerpo se emulan por medio de un phantom liquido para UWB y la caracterizacion se plantea tanto en frecuencia, en terminos del modelado de la forma y el ensanchamiento del espectro Doppler, como en tiempo, por medio del estudio de la funcion de autocorrelacion y el tiempo de coherencia del canal.

  16. Relaciones entre el sueño y la adicción

    PubMed Central

    Cañellas, Francesca; de Lecea, Luis

    2016-01-01

    Resumen La interacción entre los trastornos del sueño y el abuso de sustancias es ya conocida, pero seguramente más compleja de lo que se pensaba. Existe tanto una relación positiva entre tener un trastorno por uso de substancias y sufrir un trastorno de sueño, como viceversa. Los efectos sobre el sueño dependen de la substancia utilizada, pero se ha demostrado que tanto durante su uso como en período de abstinencia los consumidores tienen diferentes problemas de sueño y fundamentalmente un sueño más fragmentado. Sabemos que hay que tener en cuenta los problemas de sueño para evitar recaídas en la adicción. Investigaciones recientes indican que el sistema hipocretinérgico definido por el neuropéptido hipocretina/orexina (Hcrt/ox), localizado en el hipotálamo lateral e implicado entre otros en la regulación del ciclo sueño-vigilia, jugaría un papel importante en las conductas adictivas. Diferentes estudios han demostrado interacciones entre el sistema hipocretinérgico, los circuitos de respuesta aguda al estrés y los sistemas de recompensa. También sabemos que la activación optogenética selectiva del sistema hipocretinérgico incrementa la probabilidad de la transición del sueño a la vigilia, y también es suficiente para iniciar un comportamiento compulsivo de recaída adictiva. La activación del sistema hipocretinérgico podría explicar la hipervigilia asociada al estrés y a la adicción. El mayor conocimiento de esta interacción permitiría entender mejor los mecanismos de la adicción y encontrar nuevas estrategias para el tratamiento de las adicciones. PMID:23241715

  17. Neurobiología del autismo y TDAH mediante técnicas de neuroimagen: divergencias y convergencias

    PubMed Central

    Proal, Erika; Olvera, Jorge González; Blancas, Aurea S.; Chalita, Pablo J.; Castellanos, F. Xavier

    2013-01-01

    En el área clínica algunos síntomas del trastorno por déficit de atención e hiperactividad (TDAH), se presentan en los pacientes con trastorno del espectro autista (TEA). Se ha demostrado que existen alteraciones en circuitos cerebrales que impactan en fallas cognitivas y de comportamiento específicas de cada uno de estos trastornos. Sin embargo, han sido poco estudiados los correlatos cerebrales que hay detrás tanto de las similitudes como de las diferencias sintomatológicas. En la presente revisión se analizaron los estudios meta-analíticos existentes estructurales y funcionales en TDAH y TEA. Por un lado, se observaron convergencias en circuitos como el dorsal atencional, de funciones ejecutivas, visual, somatomotor y circuito de activación por defecto. Estas similitudes posiblemente explican las manifestaciones comórbidas entre los trastornos como la falla en la integración de información, motricidad fina y procesos atencionales específicos. Por otro lado, específicamente en el TDAH se observan déficits en el circuito de recompensa y ventral atencional, sistemas involucrados en la medición de efectos de reforzamiento y monitoreo atencional. En TEA los circuitos más afectados fueron los implicados en procesos de cognición social y lenguaje. En conclusión, existen correlatos neuronales en TEA que explican las manifestaciones clínicas tanto convergentes como divergentes presentes en TDAH. PMID:23897144

  18. Dinámica y crecimiento de los granos de polvo en la nebulosa protoplanetaria

    NASA Astrophysics Data System (ADS)

    de La Fuente Marcos, Carlos

    2001-06-01

    En el escenario estándar de la formación planetaria, los planetesimales (cuerpos de tamaño kilométrico) crecen a partir de granos de polvo, similares a los interestelares, embebidos en un disco gaseoso denominado nebulosa protoplanetaria. Durante esta etapa, los movimientos del gas pueden tener gran influencia en la dinámica y el crecimiento de los granos de polvo, dado que el flujo kepleriano del gas frena el movimiento de los mismos haciendo que caigan hacia el Sol, y la turbulencia inhibe la inestabilidad gravitacional de la capa de polvo. Aunque se acepta que los planetesimales fueron los elementos constituyentes de los planetas, todavía se desconoce cómo se produjo la formación de los mismos. Por esta razón, en los estudios más recientes, existe un renovado interés por comprender mejor la evolución de la capa de polvo inmersa en el disco gaseoso de la Nebulosa. El gas que fluye en el disco puede engendrar estructuras carentes de simetría axial, como por ejemplo ondas espirales y vórtices, a partir de gran variedad de mecanismos de excitación e inestabilidad. En 1995, Barge y Sommeria pusieron de manifiesto que la existencia de vórtices gaseosos persistentes en la nebulosa solar tendría importantes consecuencias sobre la formación de los planetesimales y el posterior crecimiento de los planetas gigantes. La investigación desarrollada en esta Tesis analiza la relación entre el polvo y el gas debida al acoplamiento por fricción dinámica entre ambos; en concreto, se estudia el efecto del flujo medio del gas sobre la dinámica de las partículas de polvo. El primer objetivo es investigar en profundidad los procesos de captura y crecimiento de los granos de polvo dentro de un vórtice y su posible relevancia en cuanto a la formación de los planetesimales. El segundo objetivo es la exploración de los efectos de ondas espirales propagándose en el disco gaseoso sobre la dinámica y el crecimiento de las partículas. La presencia de líneas de corriente no circulares perturba significativamente el movimiento de las partículas alrededor del Sol e incrementa su vida media en la Nebulosa. El flujo medio del gas se modela de forma simple, analizándose la dinámica y el crecimiento de las partículas mediante simulaciones numéricas. Al incrementarse la vida media y la densidad superficial de las partículas sólidas, los mecanismos de confinamiento derivados de la presencia de vórtices y ondas espirales actuan sobre el material sólido de la Nebulosa (mediante agregación colisional o inestabilidades gravitacionales) de manera mucho más eficiente que la previamente considerada. Esto ofrece nuevas posibilidades para la formación de planetesimales y núcleos de planetas gigantes, y puede explicar la formación rápida de planetas extrasolares gigantes. Además, esta Tesis analiza la respuesta de las partículas, en un disco protoplanetario con un radio de 100 UA en torno a una estrella de tipo solar, al campo gravitatorio derivado de la presencia de dos estrellas compañeras ligadas en una órbita relativamente elongada (300-1600 UA). Para llevar a cabo este análisis, se han realizado una serie de simulaciones numéricas de configuraciones jerárquicas coplanares utilizando un programa FORTRAN que integra directamente las ecuaciones del movimiento con el objeto de modelar la presencia de las fuerzas gravitacionales y viscosas. El disco protoplanetario masivo se encuentra en torno a una de las componentes de la binaria. La evolución temporal del subdisco de polvo depende directamente de la naturaleza (directa o retrógrada) de la revolución relativa de la compañera estelar, y de la temperatura y la masa del disco circunestelar.

  19. Cystic fibrosis transmembrane regulator haplotypes in households of patients with cystic fibrosis.

    PubMed

    Furgeri, Daniela Tenório; Marson, Fernando Augusto Lima; Correia, Cyntia Arivabeni Araújo; Ribeiro, José Dirceu; Bertuzzo, Carmen Sílvia

    2018-01-30

    Nearly 2000 mutations in the cystic fibrosis transmembrane regulator (CFTR) gene have been reported. The F508del mutation occurs in approximately 50-65% of patients with cystic fibrosis (CF). However, molecular diagnosis is not always possible. Therefore, silent polymorphisms can be used to label the mutant allele in households of patients with CF. To verify the haplotypes of four polymorphisms at the CFTR locus in households of patients with CF for pre-fertilization, pre-implantation, and prenatal indirect mutation diagnosis to provide better genetic counseling for families and patients with CF and to associate the genotypes/haplotypes with the F508del mutation screening. GATT polymorphism analysis was performed using direct polymerase chain reaction amplification, and the MP6-D9, TUB09 and TUB18 polymorphism analyses were performed using restriction fragment length polymorphism. Nine haplotypes were found in 37 CFTR alleles, and of those, 24 were linked with the F508del mutation and 13 with other CFTR mutations. The 6 (GATT), C (MP6-D9), G (TUB09), and C (TUB18) haplotypes showed the highest prevalence (48%) of the mutant CFTR allele and were linked to the F508del mutation (64%). In 43% of households analyzed, at least one informative polymorphism can be used for the indirect diagnostic test. CFTR polymorphisms are genetic markers that are useful for identifying the mutant CFTR alleles in households of patients with CF when it is not possible to establish the complete CFTR genotype. Moreover, the polymorphisms can be used for indirect CFTR mutation identification in cases of pre-fertilization, pre-implantation and prenatal analysis. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Perioperative management of patients with cardiac implantable electronic devices.

    PubMed

    Poveda-Jaramillo, R; Castro-Arias, H D; Vallejo-Zarate, C; Ramos-Hurtado, L F

    2017-05-01

    The use of implantable cardiac devices in people of all ages is increasing, especially in the elderly population: patients with pacemakers, cardioverter-defibrillators or cardiac resynchronization therapy devices regularly present for surgery for non-cardiac causes. This review was made in order to collect and analyze the latest evidence for the proper management of implantable cardiac devices in the perioperative period. Through a detailed exploration of PubMed, Academic Search Complete (EBSCO), ClinicalKey, Cochrane (Ovid), the search software UpToDate, textbooks and patents freely available to the public on Google, we selected 33 monographs, which matched the objectives of this publication. Copyright © 2016 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Seguridad del paciente en Radioterapia Intraoperatoria: Impacto de los elementos controlados por el Radiofisico

    NASA Astrophysics Data System (ADS)

    Tarjuelo, Juan Lopez

    Introduccion: En la administracion de la radioterapia intervienen profesionales y equipos de tratamiento, por lo que existe el riesgo de error y se precisa que dicho equipamiento funcione conforme a lo esperado. A los radiofisicos les corresponde participar en las actividades de garantia o aseguramiento de la calidad, incluyendo el control de calidad de los equipos, y en la evaluacion de los riesgos asociados. La radioterapia intraoperatoria (RIO) es una tecnica radioterapica de intensificacion de dosis, altamente selectiva, dirigida a volumenes anatomicos restringidos durante el tratamiento quirurgico oncologico, basada en la administracion de una dosis absorbida alta por medio de un haz de electrones tras el examen visual directo del lecho tumoral. Como incorporar los ultimos avances en el refuerzo de la seguridad en radioterapia es una tarea ambiciosa y compleja, resulta mas concreta y de inmediata aplicacion su introduccion en la RIO. El objetivo es analizar los elementos que reducen los riesgos y aumentan la seguridad en la RIO y su dosimetria, y valorar la funcion del radiofisico en esta labor. Material y metodos: Se emplearon el planificador Radiance de GMV y el acelerador lineal de los tratamientos de RIO Elekta Precise, controlado con el verificador diario de haces Daily QA Check 1090 y medido con las camaras de ionizacion PPC 40, FC65-G y FC65-P de PTW-Freiburg, a su vez verificadas con fuentes radiactivas adecuadas de estroncio-90 modelos CDP y CDC de IBA Dosimetry. Se realizo un analisis de modos de fallo y efectos (failure mode and effect analysis, FMEA) con el fin de identificar los elementos que forman la RIO y aplicar las herramientas necesarias para la minimizacion de los riesgos y la mejora de la seguridad en la tecnica. Se estudiaron las verificaciones diarias de dicho acelerador Precise con el control estadistico de procesos (statistical process control, SPC) y se simularon intervenciones para devolverlo al estado llamado en control. El SPC tambien se uso para estudiar la estabilidad de las camaras de ionizacion mencionadas. Se realizo la dosimetria in vivo en 45 pacientes con MOSFET reforzados mobile TN-502RDM-H, pelicula radiocromica Gafchromic MD-55-2, y se elaboro un modelo teorico para explicar los datos. Por ultimo, al precisarse el uso en RIO de la simulacion virtual y del calculo de la dosis absorbida en el paciente virtual, se ha ilustrado este apartado con la aceptacion y el estado de referencia inicial del planificador de tratamientos modulados con calculo de Monte Carlo Elekta Monaco. Para ello se utilizaron la camara de ionizacion TW31016-0104 y la matriz seven29 de PTW-Freiburg, pelicula radiocromica Gafchromic EBT-2, y diferentes maniquies. Resultados: El FMEA identifico 57 modos de fallo y efectos potenciales. No se experimentaron sucesos relativos a una administracion inadecuada de la dosis absorbida. Se identificaron las revisiones dobles y por un par como claves para reducir los riesgos asociados al equipo de profesionales involucrado en la RIO. Se identificaron tambien oportunidades de mejora con el uso de la automatizacion y el enclavamiento. En cuanto al SPC, los indices de capacidad del proceso abarcaron de 1,6 a 9,3 para un nivel de especificaciones del +/-2%. Las intervenciones simuladas alcanzaron del 2% al 34% de las sesiones de medida. Las camaras de ionizacion Farmer derivaron en direcciones opuestas en un periodo de 6 anos; aunque ello no se aprecio en los informes de calibracion del laboratorio acreditado. No derivo la camara PPC-40. En la dosimetria in vivo, las medidas de los MOSFET no se desviaron significativamente de las medidas con pelicula. Los valores centrales de las dosis absorbidas quedaron entre la dosis absorbida prescrita y la maxima, con lo que indicaron un tratamiento correcto del lecho tumoral. Las anchuras de los intervalos de confianza de las dosis absorbidas esperadas segun el modelo teorico al nivel del 95% abarcaron del 8,6% al 14,7%. Las verificaciones de Monaco resultaron satisfactorias excepto en el caso de la transferencia de datos, que obligo a cambiar el flujo de trabajo. Conclusiones: El FMEA es crucial para priorizar las intervenciones reductoras del riesgo. Tipos diferentes de procesos fallidos se pueden eliminar o paliar con tipos diferentes de tales intervenciones. El SPC puede evaluar la variabilidad inherente del procedimiento monitorizador de haces de electrones, indica cuando intervenir para devolver un proceso al estado de control y si un proceso es capaz con respecto a unas especificaciones o requisitos establecidos. Es viable realizar dosimetria in vivo con un acelerador convencional fijo y obtener resultados satisfactorios en cada localizacion estudiada a pesar de su variabilidad. El modelo teorico desarrollado puede describir con exito resultados globales, aunque no puede explicar todos los datos experimentales. Se ha mostrado que un planificador puede funcionar correctamente en condiciones de laboratorio o trabajando solo; pero puede fallar cuando se conecta con otros equipos de radioterapia. Todos estos aspectos presentados y evaluados aqui constituyen competencias actuales o futuras, y deseables, de los radiofisicos, tanto en el campo de la RIO como en la extension a la radioterapia en su conjunto.

  2. Calcium supplementation for reducing weight in people with obesity; an overview of systematic reviews

    PubMed

    Aguilera Eguía, Raúl; Jorquera Pino, Paula Jessica; Salgado, Claudia Jaqueline; Flores, Cherie

    2016-09-20

    Introducción: actualmente la obesidad es considerada un problema de salud pública, y en la mayor parte de los países ha evolucionado como una pandemia, presentando un incremento en su prevalencia y severidad.Objetivo:resumir las revisiones sistemáticas Cochrane y no Cochrane que evalúen el efecto de la suplementación de calcio en la disminución de grasa corporal en personas obesas.Materiales y métodos: se realizó una búsqueda en la base de datos Medline (1980-septiembre 2015), Metabuscador TripDatabase y Epistemonikos (hasta septiembre 2015), Cochrane BVS (hasta septiembre 2015), se buscó de forma manual en revistas relacionadas con el tema de interés, en actas de congresos, se realizó seguimiento de referencias relevantes y se contactó con expertos en el área.Resultados: la búsqueda preliminar arrojó un total de 7.163 artículos potencialmente elegibles, según los criterios de elegibilidad incluimos 2 revisiones sistemáticas de estudios clínicos aleatorizados.Conclusión: el suplemento de calcio al parecer sería efectivo en la disminución de grasa corporal, DM -0,51 (-1,27, 0,25); (p = 0,19), presentando "baja evidencia" según la metodología GRADE, esto quiere decir que "es muy probable que investigaciones adicionales tengan un impacto importante en la confianza de la estimación del efecto y es probable que cambie".

  3. Trayectoria de los tornillos pediculares lumbares y sacros: Comparación entre el abordaje por linea media versus el abordaje posterolateral tipo wiltse

    PubMed Central

    Gagliardi, Martín; Guiroy, Alfredo; Molina, Federico Fernández; Fasano, Francisco; Ciancio, Alejandro Morales; Mezzadri, Juan José; Jalón, Pablo

    2017-01-01

    Resumen Objetivos: El objetivo de este estudio fue comparar, en fusiones lumbosacras cortas, el ángulo de convergencia de los tornillos pediculares entre el abordaje posterolateral tipo Wiltse y el abordaje mediano convencional. Método: Se revisaron en forma retrospectiva los controles en tomografía axial computada (TAC) de 76 tornillos pediculares lumbares y sacros colocados por vía posterior, mediante un abordaje mediano convencional (n: 38) o por vía posterolateral transmuscular tipo Wiltse (n: 38). Se incluyeron fusiones lumbosacras cortas desde L3 a S1, en pacientes adultos, con patología degenerativa. Se excluyeron los tornillos con una brecha ósea >4 mm en cualquier dirección, los casos con instrumentaciones pediculares previas y aquellos con curvas en el plano coronal mayores de 20°. Resultados: Considerando la totalidad de los implantes, el ángulo de convergencia fue de 23,3° (+/- 15,82). La angulación promedio, en el grupo AW, fue de 29,3° (+/- 9,72). En el grupo AC, el grado de convergencia de los implantes fue de 17,2° (+/- 10,58). Esta diferencia fue estadísticamente significativa (P < 0,0001). Para el grupo AW, el grado de convergencia según nivel fue el siguiente: L3: 31,2° (+/- 1,9); L4: 31,4° (+/- 2,76); L5: 31,1° (+/- 5,62); S1: 24,2° (+/- 12,16). El promedio del ángulo del tornillo según nivel para el grupo AC fue: L3: 16° (+/- 7,16); L4: 20,3° (+/- 6,9) L5: 15,9° (+/- 13,38); S1: 15,2° (+/- 14,32). Los implantes del grupo AW tuvieron ángulos significativamente más convergentes que el grupo AC en todos los segmentos explorados. Conclusión: En las fusiones lumbosacras cortas, la utilización del abordaje tipo Wiltse permitió la colocación de tornillos pediculares con más convergencia que en el abordaje mediano convencional. La relevancia clínica de este hecho es desconocida y se requerirían trabajos prospectivos randomizados para determinar la misma. PMID:29142777

  4. Regulación del flujo sanguíneo uterino. II. Funciones de estrógeno y receptores estrogénicos α/β en acciones genómicas y no-genómicas del endotelio uterino *

    PubMed Central

    Mayra, Pastore R.; Rosalina, Villalón L.; López, Gladys; Iruretagoyena, Jesús; Magness, Ronald

    2015-01-01

    Resumen El embarazo está marcado por cambios y adaptaciones cardiovasculares que son importantes para el crecimiento y mantenimiento de la placenta y el feto. Durante este periodo, las adaptaciones vasculares uterinas manifiestan cambios clasificados como de corto o largo plazo los cuales están relacionados con adaptaciones vasodilatadoras, angiogénicas o de remodelación. El estrógeno y los receptores estrogénicos clásicos (REs), RE-α y RE-β, han demostrado ser parcialmente responsables por facilitar el incremento dramático en el fluido sanguíneo uterino necesario durante el embarazo. En ésta revisión bibliográfica se discuten la base estructural para la diversidad y selectividad funcional de los REs por el estrógeno, el papel de los REs sobre los efectos genómicos y no-genómicos en células endoteliales de arterias uterinas (CEAU). Estos temas integran el conocimiento científico sobre la regulación molecular de CEAU para mantener el incremento fisiológico en la perfusión útero-placentaria observada durante un embarazo normal. PMID:26113751

  5. Abordaje a la Cisterna Ambiens

    PubMed Central

    Ajler, Pablo; Bravo, Michael Cruz; Garategui, Lucas; Goldschmidt, Ezequiel; Isolan, Gustavo; Campero, Álvaro

    2016-01-01

    Resumen Objetivo: Describir paso a paso el abordaje a la cisterna ambiens por la vía suboccipital retrosigmoidea supracerebelosa infratentorial (SRSI). Descripción: El abordaje SRSI se realiza de la misma manera que el abordaje suboccipital retrosigmoideo (SR), utilizado habitualmente para acceder a la patología del ángulo pontocerebeloso, con las siguientes modificaciones: (1) utilizamos siempre la posición semisentado, (2) la craneotomia-craniectomia debe exponer el seno transverso y extenderse 5 cm medialmente hacia el inion, (3) al realizar la apertura dural es necesario rebatir la duramadre junto con el seno transverso hacia cefálico con puntos de tracción, (4) bajo magnificación con microscopio quirúrgico se debe realizar la apertura de la cisterna cerebelobulbar para drenar líquido cefalorraquídeo, (5) en el plano supracerebeloso es fundamental cortar las bridas aracnoidales y de ser necesario debemos coagular y cortar las venas puente, todas estas maniobras sumadas al efecto de la gravedad brindan mayor apertura del corredor supracerebeloso. Conclusión: El abordaje a la cisterna ambiens por la vía SRSI es una opción segura para el acceso de patologías tumorales que se alojan en esta zona con un componente predominantemente infratentorial. PMID:27999709

  6. Measurement and evaluation of national family planning programs.

    PubMed

    Mauldin, W P

    1967-03-01

    RESUMEN: En los últimos quince años diez paises han inaugurado programas nacionales de planeamiento familiar: India, Pakistán, Corea del Sur, Taiwan, Turquía, Malasia, Ceilán, Túez, la República Arabe Unida, y Marruecos. Otros paises, incluyendo Tailandia, Hong Kong, Singapur, Kenya, Barbados, Trinidad y los Estados Unidos, apoyan y/o estimulan actividades de planeamiento familiar. En la mayor parte de los casos la razón fundamental del programa ha sido que si la tasa de crecimiento poblacional disminuyera, aumentaría la tasa de crecimiento económico.Las metas de largo alcance, expresadas típicamente en términos de reducir las tasa.de de natalidad o de crecimiento, tienen su ejemplo en el propósito de Pakistán de reducir su tasa de crecimiento a 26 para 1970; el de Corea de reducir su tasa de natalidad a 20 para 1971; y el de India de reducir su tasa de natalidad a 25 para 1973.Los objectivos intermedios, que cubren diversos aspectos del pro grama, incluyen metas específicas para un determinado mes a año, considerando personal, la adquisición de anticonceptivos, y el número de usarios por método. Las metas específicas anuales de aceptantes de dispositivos intrauterinos (IUD), para Taiwán, Corea, Túnez, Pakistán e India, son comunes, tanto por la naturaleza del artefacto, como por la facilidad de medición de los que continúan utilizándolos. El programa de evaluación en Taiwán, que trata de medir por diversos medios los efectos inmediatos, mediatos y de largo plazo del programa de planeamiento familiar sirve de modelo. El propósito de la evaiuación de un programa de planeamiento familiar es contribuir a la efectividad y eficiencia del programa, midiendo y analizando su progreso. Las áreas a medir pueden ser clasificadas como- (1) conocimiento acerca de; (2) actitudes hacia; (3) práctica de control de natalidad; y (4) nivel de fecundidad.Un buen sistema de evaluación debería incluir: A. Un buen conjunto de estadísticas de servicio presentadas en formularios estandarizados, en las siguienies formas: 1. Informes nensuales por áreas administrativas, sobre los actuales servicios de planeamiento familiar proporcionados en la actualidad, de carácter permanente o de larga duración (al presente, esterilización y IUD de acuerdo a las siguientes características del receptor: residencia, edad, paridad (número de hijos vivos por sexo), y donde se enteró del programa, si es posible "clase";(probablemente educación de la madre, pero posiblemente ocupación del esposo, ingreso, o equivalente); prácticas anticonceptivas anteriores; intervalo; y deseo de tener más hijos. En un programa grande estos datos pueden obtenerse en base a una muestra. 2. Informes mensuales sobre la distribución de suministros anticonceptivos (condones, píldoras, sustancias efervescentes, etc.), los primeros suministros deben ir acompañados de un registro de las características del recipiente, como anteriormente; los suministros subsecuentes se regietrarán sólo en volumen bruto. Esto también se aplicará al ritmo, donde éste método se enseñe a un número considerable de mujeres. 3. Informes regulares sobre las actividades de planeamiento familiar de médicos privados, como una estimación del efecto catalítico del programa del gobierno sobre ci sector privado. 4. Datos generates mensuales, ppr áreas admirtistrativas importantes, sabre: visitas domiciliarias, reuniones, cuñas radiates y televisadas, avisos en los periódicos y personal que trabaja. 5. Para propósitos de seguimiento una entrevi eta de campo cada 6 a 12 meses a cada N mujer de las listas para (1) y (2) arriba, en un total de 300 o 400, para conocer las tasas de continuación y las razones de abandono (ej: desea otro hijo, insatisfecha can ci método, otras). Las mue.stras podrían ser de 300 cada una, con una supuesta experiencia de 6, 12, 18 y 24 meses. B. Un buen conjunto de datos sobre costa (datos sobre cotos actulaes atribuíbles directamente al programa de planeamiento familiar) fraccionados par áreas principales y cinco a seis categorías de costos importantes tales coma: adminietración, personal de campo, publicidad, suministros, etc. C. Un buen conjunto de dates globales sobre la distribución de los suministros comerciales que puedan llegar tan cerca como sea posible del último consumidor, to cual significa probablemente obtener información de los mayoristas. D. Una encuesta de conocimientos, actitudes y prácticas (KAP) para una evaluación general cada dos años. Las preguntas básicas (además de las antes mencionadas y estatus marital y étnico cuando sea pertinente) son: actitud hacia e interés por la anticoncepción, número de niños por sexo, deseo de tener más hijos, prácticas anticonceptivas, experiencia sobre abortos, tal vez historia de embarazo (especialmente si esta producirá una tasa de fecundidad válida), aprobación del programa gubernamental (para uso politico), y si está actualmente embarazada (la única y mejor pregunta cuya respuesta habla del efecto sobre la tasa de natalidad). Administrativamente, la responsabilidad por la evalucion debe estar cerca al director, se debe tomar provisiones para obtener informes regulares (meneulaes) y especiales dirigidos a preguntar sobre política. El corolario es que el jefe de evaluación debe tener la confianza del director y debe estar al día en cuanto a las decisiones sabre la politics a seguir. Su trabajo consiste en extractar los aspectos principales que funcionan bien y los no operantes. En cuanto a costos, la evaluación debe hacerse sobre no más del 10 par ciento del costa del programa en paises pequeños (de menos de 30 milliones) y sabre no más del 5 per ciento en paises más grandes.Para medir en que forma el programa satisface el criterio final-la magnitud en que cambia la fecundidad-se debe realizar un trabajo más elaborado en el centro (Universidades, Consejos de población, etc.) para desarrollar una forma (a formas) segura de traducir las estadísticas de servicio en práticas y tal vez aún datos sobre suministro comercial en datos sabre tasas de natalidad. Esto incluye, par ejemplo, los esfuerzos para consolidar observaciones coma "cinco años-mujer de usa de IUD, a 400 condones equivalen a la prevención de un nacimiento," y esfuerzos como los de Pakistán de calcular tasas coma "años de protección de una pareja contra el embarazo."In the belief that a decrease in the rate of population growth will increase economic development, more than ten countries have inaugurated family planning programs in the past fifteen years. To provide a model for measuring the immediate, intermediate, and long-term effects of any such program, the authors use the Taiwan evaluation.The model suggests that a good system of evaluation should include monthly statistics on (1) participants, who are grouped by characteristics; (2) the distribution of supplies, reported at first by the characteristics of recipients, but after by gross volume only; (3) family planning activities of private physicians to measure the catalytic effect on the private sector; (4) new contacts and amount of advertising in mass media; (5) costs broken down by areas and by cost categories; and (6) distribution of commercial supplies. In addition, the program should conduct 300-400 interviews every 6-12 months to learn the rates of continuation and the rates and reasons for discontinuation. Finally, a KAP survey should be conducted every two years.The administration of the evaluation should be close to the director for policy decisions and for the ultimate work of evaluation-the finding of new ways to measure the main goal of change in fertility by the translation of statistics on Services provided and commercial supplies into birth rate data.

  7. An Estimate of the Tidal Effects in the Dynamics of the Binary Galaxies

    NASA Astrophysics Data System (ADS)

    Junqueira, S.; de Freitas Pacheco, J. A.

    1990-11-01

    RESUMEN. Se ha estimado los efectos de marea en los pares dinamicos de galaxias elipticas. Para poder estudiar tales efectos hernos expandido el potencial gravitacional en potencias del cociente plr hasta en el orden 3 correspondientes a las fuerzas de marea. Hemos examina- do la influencia de este termino en el movimiento orbital. Se encon- tr6 el valor de M/LB = 10+7 (en unidades solares) para un ejemplo de 46 pares E-E usando Ia aproximaci6n de marea. De este resultado, no podemos concluir que existen alrededor de las galaxias halos grandes y obscuros. Hemos encontrado tambien que la suposici6n de masas puntuales es una buena aproximaci6n para el sistema fisico. Sin embargo, tal aproximaci6n sobreestima ligeramente el cociente masa-lurninosidad. ABSTRACT. In the present work we have estimated the tidal effects in the dynamics of pairs of elliptical galaxies. In order to study such effects we have expanded the gravitational potential in power of the ratio p/r up to order 3 corresponding to tidal forces. We examined the influence of this term in the orbital motion. The value of M/LB =lOi7 (in solar units) was found for a sample of 46 E-E pairs using the tidal approximation. From this result, we cannot conclude that large dark haloes exist around galaxies. We have also found that the assump- tion of point masses is a good approximation for the physical system. However, such an approximation overestimates slightly the mass-luminosity ratio. Keq wo't : GALAXIES-DYNAMICS

  8. Cochlear Implantation in Siblings With Refsum's Disease.

    PubMed

    Stähr, Kerstin; Kuechler, Alma; Gencik, Martin; Arnolds, Judith; Dendy, Meaghan; Lang, Stephan; Arweiler-Harbeck, Diana

    2017-08-01

    Whether the origin of severe hearing loss in Refsum's syndrome is caused by cochlear impairment or retrocochlear degeneration remains unclear. This case report aims to investigate hearing performance before and after cochlear implantation to shed light on this question. Also, identification of new mutations causing Refsum's syndrome would be helpful in generating additional means of diagnosis. A family of 4 individuals was subjected to genetic testing. Two siblings (56 and 61 years old) suffered from severe hearing and vision loss and received bilateral cochlear implants. Genetic analysis, audiological outcome, and clinical examinations were performed. One new mutation in the PHYH gene (c.768del63bp) causing Refsum's disease was found. Preoperative distortion product otoacoustic emissions (DPAOEs) were absent. Postoperative speech perception in Freiburger speech test was 100% for bisyllabic words and 85% (patient No. 1) and 65% (patient No. 2), respectively, for monosyllabic words. Five years after implantation, speech perception remained stable for bisyllabic words but showed decreasing capabilities for monosyllabic words. A new mutation causing Refsum's disease is presented. Cochlear implantation in case of severe hearing loss leads to an improvement in speech perception and should be recommended for patients with Refsum's disease, especially when the hearing loss is combined with a severe loss of vision. Decrease of speech perception in the long-term follow-up could indicate an additional retrocochlear degeneration.

  9. Comportamiento del Helio en estrellas químicamente peculiares

    NASA Astrophysics Data System (ADS)

    Malaroda, S. M.; López García, Z.; Leone, F.; Catalano, F.

    Las estrellas químicamente peculiares (CP) se caracterizan por tener deficiencias y sobreabundancias de algunos elementos químicos de hasta 106 veces la abundancia solar. Además presentan variaciones en las líneas espectrales. Se piensa que ello se debe a que los campos magnéticos presentes en este tipo de estrellas son principalmente dipolares, con un eje de simetría diferente del eje de rotación. La distribución de los elementos sobreabundantes y deficientes no es homogénea sobre la superficie estelar y las variaciones observadas serían una consecuencia directa de la rotación estelar. Entre los elementos con abundancia anómala se encuentra el Helio, cuyas líneas tienen intensidades que no son consistentes con una abundancia normal, que no puede ser determinada del modo usual, o sea, considerando una atmósfera con composición solar. Con el fin de determinar la abundancia de este elemento, se inició un estudio de estrellas anómalas de Helio, Hew y He strong. Además se determinarán las abundancias de otros elementos anómalos como ser el Si, Cr, Mg, Mn y Fe. Las mismas se determinan del modo tradicional, o sea: a) medida de los anchos equivalentes de las líneas de los distintos elementos analizados; b) adopción de la temperatura efectiva, gravedad y abundancia del Helio; c) cálculo del modelo de atmósfera d) comparación con las observaciones y reinicio de un proceso iterativo hasta lograr un acuerdo entre todos los parámetros analizados. Las observaciones se llevaron a cabo en el Complejo Astronómico El Leoncito. Se observaron setenta y ocho estrellas anómalas de Helio. En este momento se está procediendo a calcular las abundancias correspondientes a los distintos elementos químicos. Para ello se hace uso de los modelos de Kurucz, ATLAS9. Los cálculos NLTE de las líneas de Helio se llevan a cabo con el programa MULTI y se compararán con los realizados con el programa WIDTH9 de Kurucz (LTE), con el objeto de resaltar la importancia de los efectos NLTE.

  10. Effects of Sterilizing Agents on Microorganisms

    DTIC Science & Technology

    1963-03-01

    light increases with the incubation of Escherichia coli at 15, but the rate of in- 85. ESTUDIO DE LOS EFECTOS QUE PRODUCE duction of mutations...between the deoxyribonucleic acid content of a cell and its response to irradiation: 5-fluor- 86. ESTUDIO DE LOS EFECTOS QUE PRODUCE ouracil treated...EFFECTS OF ULTRAVIOLET LIGHT ON 84. ESTUDIO DE LOS EFECTOS QUE PRODUCE BACTERIA. III. ALTERATIONS IN THE LA LUZ ULTRAVIOLETA SOBRE LAS PHYSIOLOGICAL

  11. Iniciativas escolares y deportivas lideradas desde la Fédération Internationale de Football Association (FIFA): revisión sistemática.

    PubMed

    Correa, Jorge E; Meneses-Echávez, José F; Barengo, Noël C; Tovar, Gustavo; Ruiz-Castellanos, Erika; Lobelo, Felipe; Ramírez-Vélez, Robinson

    2015-09-01

    Introducción: Los programas iniciados por la Fédération Internationale de Football Association (FIFA) consisten en la difusión de mensajes relacionados con el cuidado de la salud y como estrategia de prevención de lesiones deportivas entre los niños y jóvenes. El objetivo de esta revisión sistemática fue resumir los resultados de la implementación de los programas "FIFA 11 para la salud" y "FIFA 11+". Métodos: Se realizó una búsqueda sistemática en las bases de datos electrónicos de MEDLINE, EMBASE y Scopus, identificando los estudios que evaluaran la implementación de los programas "FIFA 11 para la salud" y "FIFA 11+", durante los últimos 10 años (1 enero 2003 a 1 diciembre 2013). Resultados: Incluimos 17 estudios. Dos estudios evaluaron la implementación del programa "FIFA 11 para la salud" y encontraron un aumento significativo en el conocimiento de los mensajes de promoción de la salud; 15 estudios evaluaron los efectos del programa "FIFA 11+", reportando una reducción en el riesgo de lesiones deportivas y mejorías en el rendimiento deportivo. Discusión: Los programas "FIFA 11 para la salud" y "FIFA 11+" han demostrado resultados positivos para la salud, en el ámbito escolar y deportivo. Conclusiones: Dichos programas del FIFA representan una oportunidad para crear hábitos protectores y fomentar modos de vida saludables en niños y jóvenes.

  12. Breakfast of champions or kiss of death? Survival and sexual performance of protein-fed, sterile Mediterranean fruit flies (Diptera: Tephritidae)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yuval, B.; Maor, M.; Levy, K.

    The sterile insect technique (SIT) is increasingly being used around the world to control Ceratitis capitata (Wiedemann) (Diptera: Tephritidae), the Mediterranean fruit fly as part of an area-wide integrated approach. One option that may improve the effectiveness of the SIT, by increasing the sexual competitiveness of released sterile males, consists of feeding males protein during the post-teneral stage, a diet that increases sexual performance of wild males. We examine the effects of diet on the successive hurdles males must overcome in order to inseminate females, i.e., joining leks, copulating females, having their sperm stored and inhibition of female remating. Inmore » addition, we address the effects of diet on post-release foraging success, longevity, and the ability to withstand starvation. While protein feeding universally increases the sexual success of wild males, its effect on sterile males varies with strain, experimental settings, and environmental conditions. In some cases, treatments that resulted in the best sexual performance were significantly associated with increased vulnerability to starvation. However, no particular diet affected the ability of sterile males to find nutrients in the field when these where available. We suggest it may be better to release relatively short-lived flies that are highly competitive, rather than long-lived, sexually ineffective ones. (author) [Spanish] El uso de la tecnica de insecto esteril (TIE) esta aumentando alrededor del mundo para el control de Ceratitis capitata (Wiedemann) (Diptera: Tephritidae), la mosca mediterranea de la fruta como parte de un enfoque integrado por toda el area. Una opcion que puede mejorar la eficiencia de TIE, por medio del aumento de la capacidad de los machos esteriles liberados para competir, consiste en la alimentacion de los machos con proteina durante la etapa de pos-teneral, una dieta que aumenta el desempeno sexual de los machos naturales. Nosotros examinamos los efectos de la dieta sobre los obstaculos sucesivos que los machos tienen que superar para inseminar las hembras, i.e., unir con otros machos en areas para el apareamiento, copula de las hembras, almacenar esperma e inhibir el re-apareamiento de hembras. Ademas discutimos los efectos de la dieta sobre el exito de su actividad forrajera despues de ser liberados, la longevidad y la habilidad para aguantar la inanicion. Mientras que la alimentacion con proteina universalmente aumentan el exito sexual de los machos naturales, su efecto sobre los machos esteriles varia segun la raza, el lugar de los experimentos y las condiciones ambientales. En algunos casos, los tratamientos que resultaron con mejor desempeno sexual fueron asociados significativamente con el aumento de la vulnerabilidad a la inanicion. Sin embargo, ninguna dieta en particular afecto la habilidad de los machos esteriles para encontrar nutrientes en el campo cuando fueron disponibles. Nosotros sugerimos que puede ser mejor el liberar moscas que tienen una vida relativamente corta y que son mas competidoras, en vez de moscas que tienen una vida larga y sexualmente inefectiva. (author)« less

  13. ADIPOQUINAS EN EL NIÑO SANO Y AFECTO DE OBESIDAD

    PubMed Central

    Martos-Moreno, G.A.; Kopchick, J.J.; Argente, y J.

    2015-01-01

    El incremento universal de la prevalencia de obesidad en niños y adolescentes durante las últimas décadas, junto con la evidencia creciente de que el establecimiento de obesidad en etapas precoces de la vida está asociado con un incremento de la prevalencia de comorbilidades y del riesgo de muerte prematura, con gran repercusión económica en los sistemas sanitarios de los países occidentales, ha impulsado la investigación en este área. Estos estudios han remarcado la importante actividad endocrina del tejido adiposo, ejercida por medio de la síntesis y secreción de un gran número de péptidos y citoquinas, denominados adipoquinas. En esta revisión se resume el estado actual de los conocimientos, así como los estudios más relevantes, en relación con la dinámica de secreción de las principales adipoquinas en niños, centrándose en el control de la homeostasis energética, regulación metabólica (fundamentalmente, metabolismo de los hidratos de carbono) e inflamación. Asímismo, se analizan las particularidades de la síntesis, secreción y acciones de las adipoquinas desde el nacimiento hasta la adolescencia, reseñando el efecto que, sobre ellas, ejerce la instauración de la obesidad. PMID:23228441

  14. Effects of pond draining on biodiversity and water quality of farm ponds.

    PubMed

    Usio, Nisikawa; Imada, Miho; Nakagawa, Megumi; Akasaka, Munemitsu; Takamura, Noriko

    2013-12-01

    Farm ponds have high conservation value because they contribute significantly to regional biodiversity and ecosystem services. In Japan pond draining is a traditional management method that is widely believed to improve water quality and eradicate invasive fish. In addition, fishing by means of pond draining has significant cultural value for local people, serving as a social event. However, there is a widespread belief that pond draining reduces freshwater biodiversity through the extirpation of aquatic animals, but scientific evaluation of the effectiveness of pond draining is lacking. We conducted a large-scale field study to evaluate the effects of pond draining on invasive animal control, water quality, and aquatic biodiversity relative to different pond-management practices, pond physicochemistry, and surrounding land use. The results of boosted regression-tree models and analyses of similarity showed that pond draining had little effect on invasive fish control, water quality, or aquatic biodiversity. Draining even facilitated the colonization of farm ponds by invasive red swamp crayfish (Procambarus clarkii), which in turn may have detrimental effects on the biodiversity and water quality of farm ponds. Our results highlight the need for reconsidering current pond management and developing management plans with respect to multifunctionality of such ponds. Efectos del Drenado de Estanques sobre la Biodiversidad y la Calidad del Agua en Estanques de Cultivo. © 2013 Society for Conservation Biology.

  15. [Not Available].

    PubMed

    Visiedo, Andrea; Sainz de Baranda, Pilar; Crone, Diane; Aznar, Susana; Pérez-Llamas, Francisca; Sánchez-Jiménez, Regina; Velázquez, Francisca; Berná-Serna, Juan de Dios; Zamora, Salvador

    2016-07-19

    Introducción y objetivos: en el presente trabajo se ha realizado una revisión sistemática durante los últimos 15 años de los estudios científicos que se han desarrollado con el objetivo de aumentar los niveles de actividad física, mejorar la salud y disminuir la prevalencia de sobrepeso y obesidad en escolares de entre 5 y 10 años.Material y métodos: se han encontrado un total de 28 estudios: 2 revisiones sistemáticas, 2 artículos descriptivos del proceso metodológico y 24 de intervención. Se pueden diferenciar dos tipos de intervenciones, por un lado aquellas intervenciones centradas en aumentar los niveles de actividad física, y por otro, aquellas que introducen además una parte de educación y valoración nutricional.Resultados: el análisis de los resultados muestra mejoras estadísticamente significativas en el 47,3% de las intervenciones que evaluaron el IMC, en el 44,4% de las que evaluaron la composición corporal, en el 40% de las que evaluaron el índice cintura-cadera, en el 50% de las que evaluaron el sumatorio de pliegues cutáneos. En relación con los efectos sobre la condición física, destacar que en el 45,4% de las intervenciones que avaluaron la resistencia cardiovascular se observaron mejoras significativas, al igual que en el 66,6% de las que analizaron los efectos sobre la fuerza. Finalmente, se observaron cambios en los hábitos alimentarios o en el conocimiento de los escolares en alimentación y nutrición en el 66,6% de los estudios que evaluaron dichos parámetros.

  16. PubMed

    Scotta, Ana Verónica; Bongiovanni, Guillermina Azucena; Soria, Elio Andrés

    2018-03-21

    Antecedentes: Clorpirifos es un pesticida altamente tóxico, que puede producir inmunotoxicidad con efectos deletéreos sobre la salud a nivel mundial. Por otro lado, las plantas americanas pueden tener derivados con actividad protectora e inmunoestimulante. Por lo tanto, debe evaluarse el potencial de estas plantas frente a clorpirifos. Objetivo: Identificar extractos acuosos bioactivos de Lantana grisebachii (LG), Aspidosperma quebracho-blanco (AQ), Peumus boldus (PB), e Ilex paraguariensis (IP), contra la toxicidad de clorpirifos sobre esplenocitos de hembras Balb/c. Materiales y Métodos: Esplenocitos fueron tratados in vitro por 72 horas con 0-35 µg/mL de clorpirifos, 0-100 µg/mL de cada extracto (LG, AQ, PB, IP) y 0-5 µg/mL de concanavalina A. Luego, se midió y analizó estadísticamente viabilidad y muerte celular (tinciones de resazurina y yoduro de propidio), hidroperóxidos, lipoperóxidos (ensayos basados en naranja de xilenol), actividad de la ?-glutamiltranspeptidasa (método de Szasz). Resultados: Clorpirifos redujo la viabilidad celular de forma dosis dependiente, lo que fue contrarrestado por AQ e IP, los que fueron menos activos en las células inducibles por concanavalina A (p<0,05). La toxicidad por clorpirifos implicó la inducción de la ?-glutamiltranspeptidasa con la consecuente reducción de los peróxidos, mientras que AQ y principalmente IP antagonizaron dichas respuestas (p<0,05). Conclusiones: Los extractos de Ilex paraguariensis y Aspidosperma quebracho-blanco protegieron in vitro a los esplenocitos frente a clorpirifos. Este efecto dependió del tipo celular, dado que las células inducibles por concanavalina A fueron más susceptibles a este tóxico.

  17. Nanoparticulas basadas en complejos de Fe(II) con transicion de espin: sintesis, caracterizacion y aplicaciones en electronica molecular

    NASA Astrophysics Data System (ADS)

    Monrabal Capilla, Maria

    Esta tesis doctoral esta organizada en 5 capitulos y esta destinada al estudio de sistemas de Fe (II) que presentan el fenomeno de la transicion de espin a escala nanometrica. El capitulo 1 contiene una introduccion general sobre materiales moleculares multifuncionales, destacando aquellos ejemplos mas importantes. Por otro lado, se explicara el fenomeno de la transicion de espin, tratando aspectos conceptuales, los antecedentes mas importantes y la situacion actual. En el capitulo 2 se describen los diferentes procesos existentes para la obtencion de diferentes tipos de nanoparticulas. Ademas, se presenta la sintesis y caracterizacion de nanoparticulas del polimero de coordinacion unidimensional [Fe(Htrz)2(trz)]BF4, obtenidas mediante el metodo de micelas inversas. Estas nanoparticulas, con una estrecha distribucion de tamanos centrada alrededor de los 11 nm, presentan una transicion de espin muy abrupta, con un ancho ciclo de histeresis termica de unos 40K. En el capitulo 3 se describe el proceso de modificacion del tamano de las nanoparticulas descritas en el capitulo anterior, llevado a cabo variando la proporcion de surfactante/H2O en el medio. Ademas, con el objetivo de modificar las propiedades magneticas de las nanoparticulas obtenidas en el capitulo 2, se lleva a cabo la sintesis de nanoparticulas de polimeros de la misma familia del [Fe(Htrz)2(trz)]BF4. En concreto se sintetizaron 3 nuevos tipos de nanoparticulas basadas en el polimero [Fe(Htrz)1-x(NH2trz)x](ClO4)2, siendo x = 0.05, 0.15 y 0.3, en cada caso. Estas nanoparticulas siguen presentando una estrecha distribucion de tamanos y una transicion de espin muy abrupta y con un ancho ciclo de histeresis. Ademas, se observa que este ciclo se desplaza a temperaturas mas proximas a la temperatura ambiente a medida que se aumenta el porcentaje de 4-amino-1, 2, 4- triazol en la muestra. Pero al mismo tiempo se produce una disminucion de la anchura de este ciclo. Por ultimo, en este capitulo se presenta la sintesis de otro nuevo tipo de nanoparticulas, obtenidas a partir de otro polimero de la misma familia, el [FeO8ZnO2(Htrz)3](BF4). Estas nanoparticulas se sintetizaron con el objetivo de estudiar el efecto de la dilucion del metal en la muestra. Como resultado se obtuvieron nanoparticulas que tambien presentan una estrecha distribucion de tamanos pero en este caso la transicion de espin no es tan abrupta como en los casos anteriores. Aunque sigue presentando un ciclo de histeresis termica bastante ancho y a temperaturas proximas a la temperatura ambiente. En el capitulo 4 se describiran las estrategias que se han seguido para mejorar la estabilidad y afinidad sobre diferentes sustratos de las nanoparticulas sintetizadas en el capitulo 2. Tambien se hablara de los intentos realizados parar depositarlas en superficies y embeberlas en diferentes matrices organicas e inorganicas. En el capitulo 5 presentaremos la obtencion de un interruptor molecular realizado poniendo en contacto nanoparticulas individuales sintetizadas en el capitulo 2, con unos electrodos separados varios nanometros. Este dispositivo exhibe "switching" y efecto memoria a temperaturas proximas a la temperatura ambiente como consecuencia de la biestabilidad intrinseca de las nanoparticulas. Ademas demostraremos que el estado magnetico de estas nanoparticulas puede ser controlado electricamente, ya que la transicion de espin en este nanodispositivo molecular puede ser inducida simplemente aplicando un voltaje, lo que puede ser de gran interes para la electronica molecular.

  18. Effects of pre-irradiation conditioning of Medfly pupae (Diptera: Tephritidae): Hypoxia and quality of sterile males

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nestel, D.; Nemny-Lavy, E.; Islam, S.M.

    Irradiation of pupae in sterile insect technique (SIT) projects is usually undertaken in hypoxic atmospheres, which have been shown to lessen the deleterious effects of irradiation on the quality of adult sterile flies. Although this is the accepted technology in most mass-rearing and sterilization facilities, to date no information has been generated on the actual levels of oxygen (O{sub 2}) in pupae-packing containers during irradiation. The present study utilized recently-developed technology to investigate the O{sub 2} level inside bags in which pupae of Mediterranean fruit fly (medfly) Ceratitis capitata (Wiedemann) are packed prior to irradiation, the ability of pupae tomore » create hypoxic environments in these bags, and the effect of O{sub 2} atmospheres on the quality of irradiated males. Pupae, 1 d before adult emergence, were shown to deplete the O{sub 2} level in sealed bags in approximately 1 h. The rate of O{sub 2} consumption was dependent upon pupal age and incubation temperature. Incubation temperature did not significantly affect the quality of pupae or mating capacity of resultant adult males if pupae were irradiated under maximal hypoxic conditions inside packing bags. In contrast, mating competitiveness drastically decreased when pupae were irradiated under ambient O{sub 2} conditions, with the packing bag open. There was no difference in the mating capacity of males when pupae were irradiated in sealed bags under either 10% or 2% O{sub 2} levels, or under maximal hypoxia. Normal doses of fluorescent dye, applied to pupae to mark sterile flies, did not affect the ability of pupae to create hypoxic conditions inside packing bags, nor the quality control parameters of either pupae or adults. Current practices in mass-rearing facilities are discussed in the light of these results. (author) [Spanish] La irradiacion de pupas en proyectos de mosca esteril usualmente se hace bajo condiciones de hipoxia. Esta condicion ha demostrado ser menos detrimente a la calidad de las moscas que la irradiacion en atmosferas con proporcion normal de oxigeno. Aunque esta ha sido por mucho tiempo parte del protocolo de irradiacion en plantas de produccion de mosca esteril, hasta ahora no se ha medido el contenido de oxigeno dentro de los recipientes de empaque de pupa durante la irradiacion. El presente estudio investigo los contenidos de O{sub 2} en los contenedores de pupas de la mosca de las frutas del Mediterraneo (Ceratitis capitata Wiedeman), la habilidad de pupas de crear hipoxia dentro de los contenedores, y los efectos del contenido de O{sub 2} durante la irradiacion del contenedor en la calidad y capacidad de apareamiento de moscas esteriles. Pupas de un dia antes de emerger como adultos crearon atmosferas de maxima hipoxia dentro del empaque en aproximadamente una hora. La proporcion de consumo de O{sub 2} en contenedores sellados es dependiente de la edad de la pupa, y de la temperatura de incubacion. La temperatura de incubacion no afecto significativamente la calidad ni la capacidad de apareamiento de machos derivados de pupas irradiadas bajo condiciones de hipoxia. Sin embargo, la capacidad de apareamiento de machos irradiados como pupas en contenedores abiertos y en condiciones oxigenadas fue drasticamente afectada. En comparacion a los resultados anteriores, atmosferas de 2% y 10% O{sub 2} durante la irradiacion no afectaron la capacidad de apareamiento de moscas esteriles. Polvo fluorescente, aplicado a pupas para marcar las moscas esteriles, no tuvo efectos sobre la capacidad de las pupas de crear hipoxia. Los resultados de este estudio se discuten en base a las practicas actuales de produccion e irradiacion. (author)« less

  19. La problematica de la demarcacion entre ciencia y pseudociencia y sus implicaciones en la educacion cientifica

    NASA Astrophysics Data System (ADS)

    Jimenez Tolentino, Dinorah

    2011-12-01

    En la sociedad prevalece una tendencia generalizada hacia la inclusion de creencias y practicas pseudocientificas. Esta investigacion responde a la necesidad de analizar como la proliferacion de las pseudociencias afecta la vision que tienen los estudiantes universitarios sobre las ciencias naturales. A tales efectos, la investigadora describe las concepciones epistemologicas que tienen los estudiantes sobre las ciencias y las pseudociencias e identifica los criterios de demarcacion, entre un area y otra, que se derivan de estas concepciones. De igual modo, esta identifica las creencias y practicas pseudocientificas de mayor arraigo entre los estudiantes, destacando, a su vez, la razon de ser de las mismas. Por ultimo, la investigadora analiza las implicaciones educativas de la problematica de la demarcacion entre ciencia y pseudociencia. La investigacion es de naturaleza mixta, enmarcada en los paradigmas empirico- analitico y cualitativo. El proceso investigativo se llevo a cabo mediante la administracion del cuestionario Criterios para la demarcacion entre ciencia y pseudociencia. La parte cualitativa estuvo enmarcada en el diseno de estudio de caso, recopilando informacion mediante entrevistas semiestructuradas en dos grupos focales. La poblacion de estudio estuvo constituida por estudiantes universitarios del nivel subgraduado de la Universidad Central de Bayamon. Los resultados del estudio reflejaron las concepciones erroneas de los estudiantes sobre la naturaleza de las ciencias y las pseudociencias. Con respecto a la demarcacion entre ciencia y pseudociencia, el criterio imperante entre los universitarios es el de la verificabilidad, considerando la aplicacion del metodo cientifico como el metodo para demostrar la veracidad de las teorias cientificas. Las creencias y practicas pseudocientificas no son muy frecuentes entre los universitarios. Estos atribuyen las mismas a la prevalencia de elementos supersticiosos y al engano a que es sometida la poblacion por quienes promueven estas practicas. A partir de los resultados, la investigadora concluye que la problematica sobre la demarcacion entre ciencia y pseudociencia esta influenciada por unos procesos de ensenanza enfocados en una vision distorsionada de la ciencia, producto de la no integracion de los aspectos filosoficos, historicos y sociales de la misma.

  20. Effect of acclimation to outdoor condition on the sexual performance of mass-produced Medflies (Diptera: Tephritidae)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pereira, R.; Silva, N.; Quintal, C.

    Application of the sterile insect technique (SIT) as part of integrated area-wide programs to control the Mediterranean fruit fly (medfly) Ceratitis capitata (Wiedemann) require that the released males attract wild females and transfer sterile sperm. However, knowledge about male sexual performance after they are released is scarce. We conducted a study to evaluate male sexual performance in field cage tests, according to standard quality control procedures. Mass-reared 5-d-old sterile males from the genetic sexing strain VIENNA 7mix2000 were acclimated for 0, 1, and 3 d to outdoor conditions before competing with wild males for wild females. Although the proportion ofmore » mating (PM) in the test was satisfactory, the resulting relative sterility index (RSI) data showed no significant differences among the treatments. The data indicate that pre-conditioning males to outdoor conditions in Madeira did not confer an advantage in field cage sexual performance. (author) [Spanish] La aplicacion de la tecnica del insecto esteril (TIE) como parte de un programa integrado de amplio efecto para el control de la mosca mediterranea de la fruta Ceratitis capitata (Wiedemann) requiere que los machos liberados atraigan las hembras naturales y transfieran su esperma. Sin embargo, el conocimiento del desempeno sexual de los machos despues de ser liberados es muy escaso. Nosotros realizamos un estudio para evaluar el desempeno sexual de los machos en pruebas usando jaulas del campo, segun los procedimientos estandardizados de calidad. Machos esteriles de 5 dias de edad de la raza que separa los sexos geneticamente VIENNA 7mix2000 criados en masa fueron aclimatados por 0, 1 y 3 dias en condiciones de campo antes de competir con machos naturales para las hembras naturales. Aunque la proporcion del apareamiento en la prueba fue satisfactorio, el indice relativo de esterilidad (IRS) resultante no mostro ninguna diferencia significativa entre los tratamientos. Los datos indicaron que al condicionar los machos anteriormente a las condiciones de campo en Madeira no conferio ventaja alguna en el desempeno sexual en la jaula de campo. (author)« less

  1. Efectos Especiales de Anclaje (Estudio sobre Regresiones de Juicios Condicionales). Parte 1: Distincion entre Efectos Aditivos y Efectos Multiplicativos en el Fenomeno de Anclaje (Special Effects of Anchoring (Study on Regression of Conditional Judgements) Part 1: Distinction Between Additive Effects and Multiplicative Effects in the Phenomenon of Anchoring). Publication No. 17.

    ERIC Educational Resources Information Center

    Lopez Alonso, A. O.

    A linear relationship was found between judgements given by 160 subjects to 7 objects presented as single stimuli (alpha judgements) and judgements given to the same objects presented with a condition (gamma judgements). This relationship holds for alpha judgements and the gamma judgements that belong to a family of constant stimulus and varying…

  2. [Anesthetic management and experience in the transcatheter implantation of the CoreValve(®) self-expanding aortic valve].

    PubMed

    Fernández Suárez, F E; del Valle Fernández, R; González Alvarez, A; Sánchez Lasheras, J; Fernández Sánchez, L; Argüelles Tamargo, L

    2013-10-01

    To analyze the experience and anesthetic management in the transcatheter implantation of the CoreValve(®) self-expanding aortic valve, in a university tertiary hospital. Observational analytical review of data incorporated into a prospectively maintained database of 142 patients diagnosed with severe aortic stenosis who underwent implantation of a CoreValve(®) aortic self-expanding aortic valve between December 2007 and December 2012. The mean age of patients was 82.5±6.1 years and the logistic EuroSCORE was 14.9±11.2. General anesthesia was used in 107 patients (75.3%), with local anesthesia with sedation in 35 (24.6%). Local anesthesia and sedation was associated with a lower requirement of vasoactive drugs (P=.003) during implantation. No statistically significant differences were found between the 2 anesthetic techniques in the duration of the procedure, hospital stay, or morbimortality. The success rate was 97.1%. The most common complication was conduction disorders that required implantation of a permanent pacemaker in 46 patients (32.3%). There was no intraoperative mortality, and all-cause mortality at 30 days was 6.3%, with a one-year survival estimated by the Kaplan-Meier of 83.1%. This study confirms that in patients with severe aortic stenosis and high surgical risk, transcatheter implantation of aortic valve is a safe and effective alternative. Both, general anesthesia and local anesthesia with sedation are valid options, depending on the experience of the team. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  3. [In Process Citation].

    PubMed

    Gonçalves Schemitt, Elizângela; Raskopf Colares, Josieli; Minuzzo Hartmann, Renata; Morgan-Martins, María Isabel; Marroni, Cláudio Augusto; Tuñón, M Jesús; Possa Marroni, Norma

    2016-03-25

    Introducción: la insuficiencia hepática fulminante (IHF) es un síndrome clínico poco frecuente, que se caracteriza por una disfunción hepática severa y repentina. La tioacetamida (TAA) es una hepatotoxina cuya administración puede inducir necrosis centrolobulillar en las células hepáticas y aumentar la formación de especies reactivas de oxígeno y la peroxidación lipídica en ratas. La glutamina es un precursor para la síntesis de glutatión. Objetivo: el objetivo del estudio es evaluar los efectos antioxidantes de la glutamina en un modelo de rata de IHF inducida por TAA. Métodos: ratas macho Wistar se dividieron en cuatro grupos de acuerdo con el tratamiento y el tiempo de evaluación: control, glutamina (25 mg/kg), tioacetamida (400 mg/kg) y tioacetamida más glutamina. Los animales se evaluaron después de 24, 36 y 48 horas. Se recogieron muestras de sangre para el análisis de los niveles de aspartato aminotransferasa (AST), alanina aminotransferasa (ALT), fosfatasa alcalina (AP), bilirrubina total (TB) y creatinina (CRE), y muestras de hígado para evaluar la peroxidación lipídica, las sustancias reactivas al ácido tiobarbitúrico (TBARS), la actividad de las enzimas antioxidantes superóxido dismutasa (SOD), glutatión peroxidasa (GPx), catalasa (CAT) y glutatión S-transferasa (GST). Además se midieron mediante inmunohistoquímica el factor nuclear kappa N (NF-κB), el fator de necrosis tumoral (TNF-α) y la óxido nítrico sintasa inducible (iNOS). Resultados: la TAA causó alteraciones en los parámetros bioquímicos e histológicos, y el aumento de los marcadores del proceso inflamatorio. Los niveles de TBARS y la actividad de SOD y GST fueron significativamente inferiores en los grupos de glutamina en comparación con TAA. La actividad de CAT se incrementó en los animales tratados con glutamina en comparación con la TAA. La actividad GPx también fue menor a las 36 y 48 h en los animales tratados com glutamina. El daño tisular y la expresión de NF-κB, TNF-α e iNOS fueron significativamente inferiores en los animales tratados con glutamina. Conclusión: la glutamina ha demostrado tener efectos protectores contra el daño hepático en un modelo de IHF inducida por TAA en la rata.

  4. International Conference on Surface Modification of Metals by Ion Beams Held in Riva Del Garda, Italy on 12-16 September 1988 (Final Program and Abstracts)

    DTIC Science & Technology

    1988-09-16

    Precipitates in Carbon Steel by Low Dose alpha- particle bombard- mento, .M.M. Ramos. L. Amaral, M. Behar. A Vas- quez, G. Marest and F.C. Zawislak...planted martensitic low carbon steel (C - 0.2 wt%). The characteriza- tion of the precipitates is done via Conversion Electron Mbssbauer technique (CEMS... PHASE TRANSFORMATIONS OF A NITROGEN IMPLANTED AUSTENITIC STAINLESS STEEL (XO CrNITI 189) by R. Leutenecker Fraunhofer-Institut for

  5. The role of agri-environment schemes in conservation and environmental management

    PubMed Central

    Batáry, Péter; Dicks, Lynn V; Kleijn, David; Sutherland, William J

    2015-01-01

    Over half of the European landscape is under agricultural management and has been for millennia. Many species and ecosystems of conservation concern in Europe depend on agricultural management and are showing ongoing declines. Agri-environment schemes (AES) are designed partly to address this. They are a major source of nature conservation funding within the European Union (EU) and the highest conservation expenditure in Europe. We reviewed the structure of current AES across Europe. Since a 2003 review questioned the overall effectiveness of AES for biodiversity, there has been a plethora of case studies and meta-analyses examining their effectiveness. Most syntheses demonstrate general increases in farmland biodiversity in response to AES, with the size of the effect depending on the structure and management of the surrounding landscape. This is important in the light of successive EU enlargement and ongoing reforms of AES. We examined the change in effect size over time by merging the data sets of 3 recent meta-analyses and found that schemes implemented after revision of the EU's agri-environmental programs in 2007 were not more effective than schemes implemented before revision. Furthermore, schemes aimed at areas out of production (such as field margins and hedgerows) are more effective at enhancing species richness than those aimed at productive areas (such as arable crops or grasslands). Outstanding research questions include whether AES enhance ecosystem services, whether they are more effective in agriculturally marginal areas than in intensively farmed areas, whether they are more or less cost-effective for farmland biodiversity than protected areas, and how much their effectiveness is influenced by farmer training and advice? The general lesson from the European experience is that AES can be effective for conserving wildlife on farmland, but they are expensive and need to be carefully designed and targeted. El Papel de los Esquemas Agro-Ambientales en la Conservación y el Manejo Ambiental Batáry et al. Resumen Más de la mitad de las tierras europeas está bajo manejo agrícola y así ha sido durante milenios. Muchas especies y ecosistemas de interés de conservación en Europa dependen del manejo agrícola y están mostrando una declinación continua. Los esquemas agro-ambientales (EAA) están diseñados en parte para encarar esto. Los esquemas son una gran fuente de financiamiento para la conservación dentro de la Unión Europea (UE) y el mayor gasto de conservación en Europa. Revisamos la estructura de los EAA actuales a lo largo del continente. Desde que en 2003 una revisión cuestionó la efectividad general de los EAA para la biodiversidad, ha habido una plétora de estudios de caso y meta-análisis que examinan su efectividad. La mayoría de las síntesis demuestran un incremento general en la biodiversidad de las tierras de cultivo en respuesta a los EAA, con la magnitud del efecto dependiente de la estructura y el manejo del terreno circundante. Esto es importante a la luz del crecimiento sucesivo de la UE y las continuas reformas a los EAA. Examinamos el cambio en la magnitud del efecto a través del tiempo al fusionar los conjuntos de datos de tres meta-análisis recientes y encontramos que los esquemas implementados después de la revisión de los programas agro-ambientales de la UE en 2007 no fueron más efectivos que los esquemas implementados antes de la revisión. Además, los esquemas enfocados en las áreas fuera de producción (como los márgenes de campo y los setos vivos) son más efectivos en el mejoramiento de la riqueza de especies que aquellos enfocados en las áreas productivas (como los cultivos arables y los pastizales). Las preguntas sobresalientes de la investigación incluyen si los EAA mejoran los servicios ambientales, si son más efectivos en las áreas agrícolas marginales que en las áreas de cultivo intensivo, si son más o menos rentables para la biodiversidad de las tierras de cultivo que las áreas protegidas, y en cuánto influye sobre su efectividad los consejos y el entrenamiento dado a los granjeros. La lección general de la experiencia europea es que los EAA pueden ser efectivos para la conservación de la vida silvestre en las tierras de cultivo, pero son caros y necesitan ser diseñados y enfocados cuidadosamente. PMID:25997591

  6. Effects of knowledge of an endangered species on recreationists' attitudes and stated behaviors and the significance of management compliance for ohlone tiger beetle conservation.

    PubMed

    Cornelisse, Tara M; Duane, Timothy P

    2013-12-01

    Recreation is a leading cause of species decline on public lands, yet sometimes it can be used as a tool for conservation. Engagement in recreational activities, such as hiking and biking, in endangered species habitats may even enhance public support for conservation efforts. We used the case of the endangered Ohlone tiger beetle (Cicindela ohlone) to investigate the effect of biking and hiking on the beetle's behavior and the role of recreationists' knowledge of and attitudes toward Ohlone tiger beetle in conservation of the species. In Inclusion Area A on the University of California Santa Cruz (U.S.A.) campus, adult Ohlone tiger beetles mate and forage in areas with bare ground, particularly on recreational trails; however, recreation disrupts these activities. We tested the effect of recreation on Ohlone tiger beetles by observing beetle behavior on trails as people walked and road bikes at slow and fast speed and on trails with no recreation. We also surveyed recreationists to investigate how their knowledge of the beetle affected their attitudes toward conservation of the beetle and stated compliance with regulations aimed at beetle conservation. Fast cycling caused the beetles to fly off the trail more often and to fly farther than slow cycling or hiking. Slow cycling and hiking did not differ in their effect on the number of times and distance the beetles flew off the trail. Recreationists' knowledge of the beetle led to increased stated compliance with regulations, and this stated compliance is likely to have tangible conservation outcomes for the beetle. Our results suggest management and education can mitigate the negative effect of recreation and promote conservation of endangered species. Efectos del Conocimiento de una Especie en Peligro sobre las Actitudes y Comportamientos Declarados de los Recreacionistas y el Significado del Manejo de la Conformidad para la Conservación del Escarabajo Tigre de Ohlone. © 2013 Society for Conservation Biology.

  7. RASTREO DEL CANCER COLORRECTAL CONOCIMIENTO Y ACTITUD DE LA POBLACION

    PubMed Central

    CASAL, ENRIQUE R.; VELAZQUEZ, ELIZABETH N.; MEJIA, RAUL M.; CUNEO, ALDO; PEREZ-STABLE, ELISEO J.

    2014-01-01

    Resumen El rastreo de cáncer colorrectal (CCR) cuenta con fuertes evidencias en su favor. Datos preliminares indican que a pesar de ello no se lleva a cabo con la frecuencia adecuada. Se intenta aquí determinar, dentro de un Sistema de Salud que cuenta con los recursos necesarios, los elementos que facilitan o generan barreras para concretar esta práctica preventiva, cuántos individuos lo ponen en práctica y qué predice esta conducta. Se realizó una encuesta telefónica a los afiliados de una Obra Social de empleados de la Universidad de Buenos Aires, de los que 132 completaron el cuestionario (tasa de respuesta 70%). Los elementos considerados facilitadores del rastreo obtuvieron respuestas afirmativas en el 64 a 97%, mientras que los que definían barreras un 11 a 27%. En este último grupo, una categoría diferenciada la constituía el miedo a los efectos adversos: 39%, y el sentimiento de vergüenza relacionado con los procedimientos: 30%. Un 33% de los encuestados tenían hecho un método de rastreo, mayoritariamente de sangre oculta (27), sigmoideoscopía (11) y colonoscopía (20). Una mayoría afirmó que “se haría el procedimiento si el médico se lo recomendara” (95%), o “no se lo haría excepto que su médico se lo aconseje” (87%). Contestar afirmativamente que “los médicos hacen lo mejor para los pacientes” se asoció con haberse hecho un método de rastreo de CCR, OR 1.55 (IC 95%: 1.02-2.37) p: 0.04. El grupo de individuos estudiado parece bien predispuesto para el rastreo del CCR, la recomendación médica sería aquí un determinante prominente para ponerlo en práctica. PMID:19414294

  8. Soil management effect on soil quality indicators in vineyards of the Appellation of Origin "Montilla-Moriles" in southern Spain

    NASA Astrophysics Data System (ADS)

    Guzmán, Gema; Cabezas, José Manuel; Bauer, Thomas; Strauss, Peter; Winter, Silvia; Zaller, Johann; Gómez, José Alfonso

    2017-04-01

    The effect soil management on several indicators frequently used in the assessment of soil quality it is not always reflected unambiguously when measured at the field although it is normally assumed that this relation is straightforward. Within the European project VineDivers (www.vinedivers.eu), sixteen commercial vineyards belonging to the Appellation of Origin "Montilla-Moriles" (Córdoba) and covering a wide range of textural classes were selected. These farms were classified 'a priori' under two soil management categories: temporal cover crop and bare soil during the whole year. In each of the vineyards one representative inter-row was selected in order to characterise different physical, chemical and biological parameters to evaluate some aspects related to soil quality. Results indicate that the studied indicators respond clearly to soil textural class and vegetation cover biomass. However, there was no clear difference in above-ground biomass of the two management categories (Guzmán et al., 2016). These results suggest that the interpretation and extrapolation of the indicators evaluated should incorporate complementary information to characterise small variations of soil management intensity among vineyards that are apparently managed under the same management category. The communication presents this analysis based on the number and type of soil disturbance events of all vineyards. The high variability found among vineyards under the same management highlights the relevance of measuring these soil parameters used as quality indicators, instead of extrapolating from other vineyards or agricultural systems, and interpreting them according to baseline levels. References: Guzmán G., Cabezas J.M., Gómez J.A. 2016. Evaluación preliminar del efecto del manejo del suelo en indicadores que determinan su calidad en viñedos de la Denominación de Origen Montilla Moriles. II Jornadas de Viticultura SECH. Madrid.

  9. Evaluation of HLA-G 14-bp ins/del and +3142G>C polymorphisms with susceptibility to recurrent spontaneous abortion.

    PubMed

    Hashemi, Mohammad; Mokhtari, Mojgan; Khazaeian, Safura; Bahari, Gholamreza; Rezaei, Maryam; Nakhaee, Alireza; Taheri, Mohsen

    2017-06-01

    HLA-G is critically important for successful implantation during pregnancy. Increasing evidence supposed that HLA-G plays a key role in tolerance of the semi-allogeneic graft in pregnancy by inhibiting the cytotoxic functions of T and NK cells. The present study aimed to evaluate the impact of HLA-G rs1063320 (+3142G>C) and 14-bp insertion (ins)/deletion (del) polymorphisms on recurrent spontaneous abortion (RSA). Genomic DNA from 93 RSA patients and 93 normal fertile women was isolated using the salting out method. Genotyping of HLA-G +3142G>C and 14-bp ins/del variants was done by polymerase chain reaction restriction fragment length polymorphism (PCR-RFP) and PCR method, respectively. The HLA-G +3142G>C polymorphism increased the risk of RSA in codominant (OR = 2.39, 95%CI = 1.27-4.49, p = 0.010, GC vs GG; OR = 3.28, 95%CI = 1.16-9.72, p = 0.040, CC vs GG) and dominant (OR = 2.52, 95%CI = 1.37-4.64, p = 0.004, GC + CC vs GG) tested inheritance models. HLA-G rs1063320 C allele was associated with increased risk of RSA (OR = 1.84, 95%CI = 1.20-2.83, p = 0.007). The del/del genotype as well as del allele of 14-bp ins/del variant increased that risk of RSA (OR = 3.02, 95%CI = 1.23-7.41, p = 0.025 and OR = 1.65, 95%CI = 1.09-2.50, p = 0.022, respectively). In summary, our results showed that HLA-G gene polymorphisms significantly increased the risk of RSA in a sample of the Iranian population. Copyright © 2017. Published by Elsevier B.V.

  10. PubMed

    Ávila García, Manuel; Huertas Delgado, Francisco Javier Huertas Delgado; Tercedor Sánchez, Pablo

    2016-11-29

    Introducción: España es el tercer país europeo con mayor prevalencia de obesidad infantil, dando lugar a la aparición de programas de intervención destinados a fomentar hábitos alimentarios saludables y/o de actividad física (AF).Objetivo: el propósito de esta revisión sistemática fue conocer aquellos programas de intervención para la promoción de hábitos alimentarios y de AF desarrollados en escolares españoles de Educación Primaria (EP) y analizar la influencia que han tenido las intervenciones sobre la composición corporal, los hábitos alimentarios y la AF.Método: se revisaron los artículos publicados entre los años 2000 y 2015 en las siguientes bases de datos: Web of Science, Scopus, Dialnet, PubMed, Eric, Sportdiscus y Psycinfo por dos revisores independientes.Resultados: se contabilizaron un total de 813 artículos, de los cuales tras la eliminación de duplicados (192), lectura de títulos y resumen (587) y lectura del texto completo (17), tan solo 7 cumplieron con los criterios de inclusión.Conclusiones: los programas de intervención analizados mostraron cambios positivos en la mejora de la composición corporal en algo menos de la mitad de los estudios analizados; por otro lado, casi todos los programas de intervención analizados tuvieron un efecto positivo sobre conductas respecto a ciertos hábitos alimentarios, como la ingesta de frutas, y sobre el incremento del nivel de AF.

  11. Inverse modeling of groundwater flow in the semiarid evaporitic closed basin of Los Monegros, Spain

    NASA Astrophysics Data System (ADS)

    Samper-Calvete, F. J.; García-Vera, M. A.

    Only minor attention has been given in the past to the study of closed-basin hydrogeology in evaporitic environments, because these basins usually contain poor-quality groundwater. The motivation for hydrogeological research in the Los Monegros area in northeastern Spain was the approval in 1986 of a large irrigation project in the Ebre River basin. The irrigation of 60,000 ha is planned, partly in an evaporitic closed basin containing playa lakes. The project has given rise to environmental concerns. The evaluation of the hydrologic impacts of irrigation requires quantifying properly the hydrogeology of the area. With the available information, a conceptual hydrogeological model was formulated that identifies two main aquifers connected through a leaky aquitard. On the basis of the conceptual model, a numerical model was calibrated under steady-state conditions using the method of maximum-likelihood automatic parameter estimation (Carrera and Neuman, 1986a). The calibrated model reproduces the measured hydraulic heads fairly well and is consistent with independent information on groundwater discharge. By the solution of the inverse problem, reliable parameter estimates were obtained. It is concluded that anisotropy plays a major role in some parts of the lower aquifer. The geometric average of model conductivity is almost two orders of magnitude larger than the average conductivity derived from small-scale field tests. This scale effect in hydraulic conductivity is consistent with the findings of Neuman (1994) and Sánchez-Vila et al. (1996). Résumé Dans le passé, on s'est peu intéresséà l'hydrogéologie des bassins fermés en milieu évaporitique, parce que ces bassins possèdent en général de l'eau souterraine de qualité médiocre. L'intérêt porté aux recherches hydrogéologiques dans la région de Los Monegros, dans le nord-est de l'Espagne est dûà l'approbation en 1986 d'un vaste projet d'irrigation dans le bassin de l'Ebre. L'irrigation de 60000 ha a été programmée, en partie dans un bassin évaporitique fermé où existent des lacs de playa. Le projet a fait émergé des préoccupations environnementales. L'évaluation des impacts hydrologiques de l'irrigation implique de quantifier correctement l'hydrogéologie de cette région. A partir des informations disponibles, un modèle hydrogéologique conceptuel a étéétabli il identifie deux aquifères principaux interconnectés par drainance au travers d'un imperméable. Un modèle numérique, établi sur la base de ce modèle conceptuel, a été calibré en conditions de régime permanent, en utilisant la méthode d'estimation automatique du maximum de vraisemblance des paramètres (Carrera and Neuman, 1986a). Le modèle calibré reproduit correctement la piézométrie mesurée et est en accord avec les informations concernant l'écoulement des nappes. La résolution du problème inverse a fourni des estimations acceptables des paramètres. On en a conclu que l'anisotropie joue un rôle essentiel dans certaines parties de l'aquifère inférieur. La moyenne géométrique de la conductivité hydraulique est d'environ deux ordres de grandeur plus élevée que la conductivité hydraulique moyenne obtenue par des essais de terrain à l'échelle locale. Cet effet d'échelle sur la conductivité hydraulique est conforme aux résultats obtenus par Neuman (1994) et Sánchez-Vila et al. (1996). Resumen La hidrogeología de zonas endorreicas en zonas evaporíticas ha recibido muy poca atención en el pasado debido fundamentalmente a que en estas zonas las aguas subterráneas tienen una elevada salinidad debido a la alta solubilidad de sus materiales. El interés por la hidrogeología de la zona de Los Monegros en el noreste de España surgió a raiz de la aprobación en 1986 del proyecto de Los Monegros II en la zona central del valle del Ebro que contempla la puesta en regadío de 60,000 ha, algunas de las cuales se encuentran situadas en la zona endorreica de Los Monegros en la que existen toda una serie de lagunas salinas. La implantación del regadío en esta zona puede alterar el régimen hidrológico de las lagunas, provocar problemas de salinización de suelos y aguas y aumentar la salinidad del río Ebro. Con el fin de evaluar estos efectos se construyó un modelo numérico del flujo subterráneo. Con la información disponible se pueden distinguir dos acuíferos que están conectados mediante un acuitardo. El modelo de flujo se calibró en régimen estacionario utilizando el procedimiento de calibración automática de Carrera y Neuman (1986a) basado en el método de la máxima verosimilitud. El modelo finalmente calibrado es capaz de reproducir los niveles piezométricos medidos y es coherente con los resultados de los balances hidrológicos en las lagunas. La conductividad hidráulica media del modelo es superior en casi dos órdenes de magnitud a la media de las conductividades hidráulicas obtenidas en ensayos de campo a escala local. Este efecto de escala en la conductividad hidráulica es coherente con los resultados de Neuman (1994) y Sánchez-Vila et al. (1996) y confirma que dicho efecto también se observa en medios evaporíticos.

  12. Survey of Foreign Systems for Incineration and Energy Recovery.

    DTIC Science & Technology

    1983-04-01

    grab * Carga del incinerador con cuchara de mandibulas A* Capacite 1 000 kg/h, implants. en ploins nature e Capacity 1 000 kg/h erected in the country...North Valley Road Xenia, Ohio N62583-82-MT- 150 L Approved for public release; distribution unlimited 88 04 29 042 1966 .I a .r I Air ~~ Y In~ 77- 7 77...selected for field visits DD ,’ 0,, 1473 LOIko oe uoecUnclass ifi ed SICuRITY CLAS~riCAtION OF Y .41S PAQL (*%.A Per& E01,e,.E . . ,.- -. CONTENTS

  13. [Migration of a stent implanted in the pulmonary artery of a patient with tetralogy of Fallot].

    PubMed

    Palomero Rodríguez, M A; Gabaldón Rivilla, M; Cabestrero Alonso, D; Gonzalez Cibrián, C; Abelleira Pardeiro, C; Centella Hernánez, T; Collado Gutierrez, R; Asuero de Lis, M S; Gómez González, R

    2014-05-01

    Tetralogy of Fallot is a congenital heart disease that accounts for 11-13% of the congenital cardiomyopathies. Stenosis and hyperplasia of the pulmonary arteries occur in a high proportion of them as this disease causes a native stenosis of the pulmonary branch, which can be surgically repaired with a stent. The use of balloon expandable intravascular stents is an alternative technique to further surgery in patients with congenital heart diseases. However, despite the gradual increase in their use, the limited number of procedures, combined with the wide anatomical variability and different characteristics of these patients, even in expert hands, stent implants are associated with a not inconsiderable incidence of complications. These are not always obvious and often require performing surgery in patients who have already had multiple interventions, thus increasing the complexity and the risk. Copyright © 2013 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Published by Elsevier España. All rights reserved.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meats, A.

    Both wild and released (sterile) Bactrocera tryoni (Froggatt) (Diptera: Tephritidae) and wild Bactrocera papayae (Drew and Hancock) in Australia had patchy distributions and comparisons with predictions of the negative binomial model indicated that the degree of clumping was sometimes very high, particularly at low densities during eradication. An increase of mean recapture rate of sterile B. tryoni on either of 2 trap arrays was not accompanied by a reduction in its coefficient of variation and when recapture rates were high, the percentage of traps catching zero decreased only slightly with increase in recapture rate, indicating that it is not practicablemore » to decrease the heterogeneity of dispersion of sterile flies by increasing the number released. There was often a mismatch between the dispersion patterns of the wild and sterile flies, and the implications of this for the efficiency of the sterile insect technique (SIT) were investigated with a simulation study with the observed degrees of mismatch obtained from the monitoring data and assuming the overall ratio of sterile to wild flies to be 100:1. The simulation indicated that mismatches could result in the imposed rate of increase of wild flies being up to 3.5 times higher than that intended (i.e., 0.35 instead of 0.1). The effect of a mismatch always reduces the efficiency of SIT. The reason for this asymmetry is discussed and a comparison made with host-parasitoid and other systems. A release strategy to counter this effect is suggested. (author) [Spanish] Las moscas naturales y liberadas (esteriles) de Bactrocera tryoni (Froggatt) (Diptera: Tephritidae) y Bactrocera papayae (Drew and Hancock) en Australia tuvieron distribuciones en parches y sus compariciones con las predicciones de un modelo binomial negativo indicaron un nivel de agregacion a veces fue muy alto, particularmente en las densidades bajas durante de eradicacion. Un aumento en el promedio de la tasa de B. tryoni esteriles recapturadas en las dos formas de trampas no fue acompanado por una reduccion en su coeficiente de variacion y cuando las tasas de moscas recapturadas fue alto, el porcentaje de las trampas que capturaron ninguna mosca bajo solo un poco con un aumento en la tasa de las moscas recapturadas, esto indico que no es practicable bajar la heterogenicidad de dispersion de las moscas esteriles por medio de un aumento el numero de moscas liberadas. Muy a menudo se encontro un desajusto entre los patrones de dispersion de las moscas naturales y esteriles, y las implicaciones de esto para la eficiencia de la tecnica del insecto esteril (TIE) fueron investigadas en un estudio de simulacion con los grados de desajustes observados obtenidos de los datos del monitoreo y se considero que la razon general del numero de moscas esteriles a moscas naturales fueron 100:1. La simulacion indico que los desajustes en los patrones de dispersion pueden resultar en una tasa impuesta sobre el aumento de las moscas naturales de hasta 3.5 veces mas alta que la tasa intentada (i.e., 0.35 en vez de 0.1). El efecto de un desajuste siempre reduce la eficiencia de TIS. Se discute la razon para esta asimetria y una comparicion hecha con el sistema de hospedero-parasitoid y otros sistemas. Se sugiere una estrategia de liberacion para contrarrestar este efecto. (author)« less

  15. Measurement of Family-centered care perception and parental stress in a neonatal unit.

    PubMed

    Balbino, Flávia Simphronio; Balieiro, Maria Magda Ferreira Gomes; Mandetta, Myriam Aparecida

    2016-08-08

    to evaluate the effects of the implementation of the Patient and Family-Centered Care Model on parents and healthcare perceptions and parental stress. a quasi-experimental study developed in a neonatal unit of a university hospital in the municipality of São Paulo, Brazil, with the implementation of this model of care. Data collection were performed by two sample groups, one using non-equivalent groups of parents, and another using equivalent groups of healthcare professionals. The instruments Perceptions of Family-Centered Care-Parent Brazilian Version, Perceptions of Family-Centered Care-Staff Brazilian Version and Parental Stress Scale: Neonatal Intensive Care Unit, were applied to 132 parents of newborns hospitalized and to 57 professionals. there was a statistically significant improvement in the perceptions of the parents in most items assessed (p ≤0,05) and for the staff in relation to the family welcome in the neonatal unit (p = 0.041) and to the comprehension of the family's experience with the infant´s hospitalization (p = 0,050). There was a reduction in the average scores of parental stress, with a greater decrease in the Alteration in Parental Role from 4,2 to 3,8 (p = 0,048). the interventions improved the perceptions of parents and healthcare team related to patient and family-centered care and contributed to reducing parental stress. avaliar os efeitos da implementação do Modelo do Cuidado Centrado no Paciente e Família na percepção de pais e profissionais de saúde e no estresse parental. Estudo quase experimental com grupos não equivalentes para avaliação dos efeitos da intervenção na percepção de pais; e com grupos equivalentes para a avaliação na percepção de profissionais de saúde, desenvolvido na unidade neonatal de um hospital universitário do município de São Paulo. Os instrumentos, Percepção do Cuidado Centrado na Família- Pais versão brasileira, Percepção do Cuidado Centrado na Família- Equipe versão brasileira e Parental Stress Scale: Neonatal Intensive Care Unit, foram aplicados com 132 pais de recém-nascidos internados e 57 profissionais da equipe. houve melhora estatisticamente significante na percepção dos pais na maioria dos itens avaliados (p≤0,05) e para os profissionais em relação ao acolhimento da família na unidade neonatal (p= 0,041) e a compreensão da vivência da família com a hospitalização (p=0,050). Houve redução dos escores médios do estresse parental, com maior queda na Alteração do Papel de Pais de 4,2 para 3,8 (p=0,048). as intervenções realizadas melhoraram a percepção de pais e de profissionais da equipe de saúde sobre o Cuidado Centrado no Paciente e Família e contribuíram para a redução do estresse parental. evaluar los efectos de la implementación del Modelo del Cuidado Centrado en el Paciente y la Familia en la percepción de los padres y profesionales de la salud y en lo estrés parental. estudio cuasi-experimental con grupos no equivalentes para evaluar los efectos de la intervención en la percepción de los padres; y grupos equivalentes para evaluar la percepción de los profesionales de la salud, desarrollado en la unidad neonatal de un hospital universitario en el municipio de Sao Paulo. Los instrumentos de Percepción del Cuidado Centrado en el Paciente y la Familia- Padres versión brasileña, Percepción del Cuidado Centrado en el Paciente y la Familia-Equipo versión brasileña y Parental Stress Scale: Neonatal Intensive Care Unit, se aplicaron a 132 padres de los recién nacidos hospitalizados y 57 profesional del equipo. se observó una mejoría estadísticamente significativa en la percepción de los padres en la mayoría de los ítems evaluados (p = 0,05) y para los profesionales en relación con el cuidado de la familia en la unidad neonatal (p = 0,041) y la comprensión de la experiencia de la familia con la hospitalización (p = 0,050). Hubo una reducción en las puntuaciones medias de estrés de los padres, con una mayor disminución en la Alteración del Rol Parental 4.2 a 3.8 (p = 0,048). las intervenciones mejoran la percepción de los padres y los profesionales del equipo de salud en el Cuidado Centrado en el Paciente y la Familia y ha contribuido a reducir el estrés de los padres.

  16. Aquifer overexploitation: what does it mean?

    NASA Astrophysics Data System (ADS)

    Custodio, Emilio

    2002-02-01

    Groundwater overexploitation and aquifer overexploitation are terms that are becoming common in water-resources management. Hydrologists, managers and journalists use them when talking about stressed aquifers or some groundwater conflict. Overexploitation may be defined as the situation in which, for some years, average aquifer ion rate is greater than, or close to the average recharge rate. But rate and extent of recharge areas are often very uncertain. Besides, they may be modified by human activities and aquifer development. In practice, however, an aquifer is often considered as overexploited when some persistent negative results of aquifer development are felt or perceived, such as a continuous water-level drawdown, progressive water-quality deterioration, increase of ion cost, or ecological damage. But negative results do not necessarily imply that ion is greater than recharge. They may be simply due to well interferences and the long transient period that follow changes in the aquifer water balance. Groundwater storage is depleted to some extent during the transient period after ion is increased. Its duration depends on aquifer size, specific storage and permeability. Which level of "aquifer overexploitation" is advisable or bearable, depends on the detailed and updated consideration of aquifer-development effects and the measures implemented for correction. This should not be the result of applying general rules based on some indirect data. Monitoring, sound aquifer knowledge, and calculation or modelling of behaviour are needed in the framework of a set of objectives and policies. They should be established by a management institution, with the involvement of groundwater stakeholders, and take into account the environmental and social constraints. Aquifer overexploitation, which often is perceived to be associated with something ethically bad, is not necessarily detrimental if it is not permanent. It may be a step towards sustainable development. Actually, the term aquifer overexploitation is mostly a qualifier that intends to point to a concern about the evolution of the aquifer-flow system in some specific, restricted points of view, but without a precise hydrodynamic meaning. Implementing groundwater management and protection measures needs quantitative appraisal of aquifer evolution and effects based on detailed multidisciplinary studies, which have to be supported by reliable data. Resumé. La surexploitation de l'eau souterraine et la surexploitation des nappes sont des termes qui deviennent d'usage commun en gestion de l'eau. Plusieurs hydrologues, aménageurs et journalistes en font usage quand on parle d'une nappe exploitée intensivement et qui présente des situations conflictives. On peut définir la surexploitation comme étant la situation dans laquelle l'extraction moyenne d'eau souterraine est plus grande ou proche de la recharge moyenne pendant quelques années. Mais le taux ansi que la surface de cette recharge sont souvent tres incertains et peuvent changer dûs a des activitées humaines et à l'exploitation de la nappe elle-méme. Du point de vue pratique on souvent considère qu'il y a surexploitation quand on observe or on s'aperçoit de certains résultats négatifs de l'exploitation, tels qu'une diminution continue du niveau de l'eau, une detérioration de sa qualité, une augmentation du coût d' extraction, ou dommages écologiques. Mais ces effets négatifs n' impliquent pas nécessairement que l'extraction soit plus grande que la recharge. Ils peuvent étre simplement le résultat d'interférences ou d'une longue période transitoire qui suivent les changements dans les termes du bilan hydrique. Cette période transitoire a une durée que dépend de la taille de la nappe, et de son coefficient d' emmagasinement et de sa perméabilité. Les extractions d'eau de la nappe comportent une diminution de l'emmagasinement d'eau souterraine pendant le période transitoire. A fin de pouvoir décider du degré de "surexploitation de la nappe" conseillé ou admisible on a besoin de la description detaillée et à jour des effets de l'exploitation et des mesures de correction adoptées. Cette décision ne peut pas étre prise uniquement à partir de regles générales et l'appui de quelques observations indirectes. On a besoin de controle, d'une bonne connaissance de la nappe, et de calculer ou modeliser le comportement, en faisant appel à l'ensemble des objectifs et politiques établies par une institution de gestion, avec l'implication des personnes qui sont intéressées par l'eau souterraine, et tenant compte des conditions environmentales et sociales. La surexploitation de nappes, qui souvent est associée a quelque chose éthiquement nocive, n'est pas necessairement ainsi pendant un certain temps, et peut être une étape dans l'évolution vers un développement durable. Réellement la designation de surexploitation de nappes est surtout un adjectif que a pour but de qualifier une évolution préoccupante sous certains points de vue, mais sans une signification hydrodynamique précise. Pour adopter des mesures de gestion et protection, on a besoin de l'évaluation quantitative de l'évolution de la nappe et de ses effets, ce qui doit déboucher sur des études detaillées dans un contexte multidisciplinaire, et sur de bonnes données. Resumen. La sobreexpolotación del agua subterránea y la sobreexplotacion de acuíferos son conceptos que se están convirtiendo en términos de uso común en gestión hídrica. Muchos hidrólogos, gestores y periodistas las usan para referirse a un acuífero explotado intensamente o que presenta situaciones conflictivas. La sobreexplotación se puede definir como la situación en la que durante varios años la extracción media de agua subterránea de un acuífero supera o se aproxima a la recarga media. Pero la tasa y también la superficie sobre la que se realiza esta recarga son a menudo muy inciertas, y pueden cambiar por actividades humanas y por la propia explotación del acuífero. Sin embargo, en la práctica se suele considerar que hay sobreexplotación cuando se observan o se perciben ciertos resultados negativos de la explotación, tales como un descenso continuado del nivel del agua, un deterioro de su calidad, un encarecimiento del agua extraída, o daños ecológicos. Pero estos efectos no están necesariamente relacionados con el hecho de que la extracción sea mayor que la recarga, puesto que pueden ser simplemente el resultado de interferencias o del dilatado período transitorio que sigue a los cambios en los términos del balance de agua, y cuya duración depende del tamaño del acuífero, y de su permeabilidad y coeficiente de almacenamiento. Las extracciones del acuífero suponen una disminución del almacenamiento de agua subterránea durante este periodo transitorio. Para decidir que grado de "sobreexplotación del acuífero" es aconsejable o admisible hace falta la consideración detallada y actualizada de los efectos de la explotación y las medidas de corrección que se adopten. Para esa decisión no basta con reglas generales y el apoyo de algunas observaciones indirectas. Se necesitan observaciones de control, buen conocimiento del acuífero y cálculos o modelación del comportamiento, y todo ello en el marco de un conjunto de objetivos y políticas establecidas por una institución de gestión, con la implicación de aquellos que tienen un interés en el agua subterránea, y teniendo en cuenta los condicionantes ambientales y sociales. La sobreexplotación de acuíferos, que con frecuencia suele asociarse a algo éticamente malo, no tiene por qué ser necesariamente así durante cierto tiempo, sino una etapa en la evolución hacia un desarrollo sustentable. En la realidad la designación de sobreexplotación de acuíferos es principalmente un adjetivo que trata de calificar a una evolución preocupante bajo determinados puntos de vista, sin que tenga una significación hidrodinámica precisa. Para adoptar medidas de gestión y de protección se necesita la evaluación cuantitativa de la evolución del acuífero y sus efectos, que se derivan de estudios de detalle en un contexto multidisciplinar y de datos fiables.

  17. [Not Available].

    PubMed

    San Mauro-Martín, Ismael; Collado-Yurrita, Luis; Blumenfeld-Olivares, Javier Andrés; Cuadrado-Cenzual, María Ángeles; Calle-Purón, María Elisa; Hernández-Cabria, Marta; Garicano-Vilar, Elena; Pérez-Arruche, Eva; Arce-Delgado, Esperanza; CiudadCabañas, María José

    2016-06-30

    Introducción: la hipercolesterolemia es uno de los principales factores de riesgo en la enfermedad cardiovascular. Los esteroles vegetales se han postulado como agentes reguladores y beneficiosos para el control de esta.Objetivo: analizar el efecto de los esteroles vegetales añadidos en una leche en la reducción del colesterol plasmático en adultos jóvenes.Métodos: ensayo clínico, controlado, aleatorizado, doble ciego y cruzado. Los esteroles (2,24 g diarios) fueron administrados en dos tomas de 350 ml de una leche comercial desnatada, durante dos periodos de 3 semanas, separados por una "fase de lavado" de 2 semanas, en el grupo experimental. Al grupo control se le administró la misma cantidad de leche desnatada, sin esteroles. Tanto al inicio como al final de cadaperiodo de intervención se extrajeron muestras sanguíneas. Se analizaron la composición corporal, hábitos de salud y los siguientes marcadores sanguíneos: perfil lipídico, hematológico, inflamación, etc.Resultados: se incluyeron 54 personas en el estudio con una edad media de 38,8 ± 7,3 años. La diferencia porcentual entre los marcadores basales y finales para el colesterol total, colesterol-LDL, colesterol-HDL, triglicéridos y colesterol no-HDL fueron del 9,73%, 12,5%, 1,9%, 3,15% y 13,2%, respectivamente. Se obtuvieron diferencias estadísticamente significativas entre el grupo experimental y el grupo control, para todos los marcadores analizados excepto para los triglicéridos.Conclusión: los esteroles vegetales suministrados en un alimento de consumo habitual, como la leche, pueden ser una estrategia terapéutica no farmacológica para el control de la hipercolesterolemia de alto interés sanitario.

  18. Strange Stars, Neutron Stars and Pulsar Emission

    NASA Astrophysics Data System (ADS)

    Benvenuto, O. G.; Horvath, J. E.

    1990-11-01

    RESUMEN. Se ha conjeturado que una partlecula de dieciocho quarks, sin Carga, sin espi'n y sin colar (quark-alfa) podri'a ser estable a ba5as tern peraturas y presiones aiTh COfl respecto a materia extrafla. Presentamos en este trabajo la estmctura de estrellas extraflas incluyendo los efectos y apariencia de parti'culas uark-alfa en las capas exteriores. La estruc tura interna ya no es hoinogenea del centro a la superficie, sino que muestra un centro de materia extrafla, capas s6lidas y una costra delgada de materia normal en la superficie. La superficie de materia nonnal permite la fornaci6n de una magnetosfera, la que se piensa sea el sitlo en donde ocurre la emisi6n del pulsar. La superficie de superflui'do ayuda a explicar el fen6rneno de `glitch', el cual ba sido observado en muchos pulsares. Se discute la ecuaci6n de estado para rnateria quark-alfa relevante en este regimen. ABSTIZACT:It has been conjectured that an quark, uncharged, spinless and colorless particle Cquark-alpha) could be stable at low pressures and temperatures even with respect to strange matter. We present in work tlie structure of stars including the effects of the appearance of quark-alpi' particles ii their outer layers. The internal structure is no longer from tlie center to the surface, but show a strange matter core, a solid and superfluid layers and a thin crust of normal matter at the surface. The normal matter surface allows tlie fon tion of a magnetosphere, whicl is to be tl place where pulsar emission occurs. A superfluid layer helps to explain tlie glitch , wlflch has been observed in . equation of state for quark-alpha matter relevant in regime is also discussed. Keq LA)OtL : ARY S - OF STATF - ?.ACT

  19. Medición de los parámetros cosmológicos q0, ΩM, y ΩΛ, usando supernovas de Tipo Ia distantes

    NASA Astrophysics Data System (ADS)

    Clocchiatti, A.; High-Z Sne Search Team

    Las supernovas de tipo Ia son una herramienta de gran precisión para la medición de distancias de interés cosmológico. Los métodos recientes de calibración de su luminosidad intrínseca, que hacen uso de la forma de las curvas de luz en varios colores y permiten diferenciar entre supernovas distantes, intrínsecamente débiles, u oscurecidas por extinción, reducen la dispersión del método que las asume de magnitud absoluta constante de 0.50 mag a 0.15 mag, e incrementa el valor de la constante de Hubble de ~55 km s-1 Mpc-1, a 65 km s-1 Mpc-1. A partir de la calibración de las supernovas cercanas, con redshifts menores que 0.1, se pueden obtener distancias precisas a supernovas que explotan a alto redshift. Hemos aplicado estos métodos a 16 supernovas con 0.16 < Z < 0.97, encontrando que sus distancias son, en promedio, entre 10% y 13% (dependiendo del método empleado) mayores que las que uno esperaría en un universo con poca masa (Ω = 0.2), sin una constante cosmológica. Todos los métodos de ajuste de curvas de luz, y selección de subgrupos de la muestra de supernovas observadas, favorecen consistentemente modelos del universo que se expanden eternamente y que tienen una constante cosmológica positiva (ΩΛ > 0), y una aceleración de la expansión al presente (q0 < 0). Hay distintas fuentes de posibles errores sistemáticos que merecen ser analizadas, entre ellas: evolución de la metalicidad y estrellas progenitoras, extinción, bias en la elección de la muestra, amplificación por gravitational lensing, y contaminación de la muestra. Ninguno de estos efectos alcanza para reconciliar los datos con ΩΛ = 0, o q0 > 0.

  20. The Evolution of Population III Objects

    NASA Astrophysics Data System (ADS)

    de Araujo, J. C. N.; Opher, R.

    1990-11-01

    RESUMEN. Estudiamos el enfriamiento y colapso de las perturbaciones iso- termicas de masa M % Mj (masa de Jeans en la era de recombinaci6n) y M « Mj tomando en consideraci5n la expansi6n del Universo, presi6n, arrastre de fotones, enfriamiento de fotones (calentamiento), fotoioni- zaci6n, ionizaci5n por colisiones y la formaci6n y enfriamiento de mo- leculas de hidr6geno. Tambien estudiamos el efecto de no-esfericidad, rotaci6n y campos magneticos en el colapso de M % Mj debido a perturbaciones residuales que sobreviven para N « Mj. ABSTRACT. We study the cooling and collapse of isothermal perturbations of mass N % Nj (Jeans mass at recombination era) and N « NJ taking into account the expansion of the Universe, pressure, photon-drag, photon -cooling (heating), photoionization, collisional ionization and the formation and cooling of hydrogen molecules. We also study the effect of the nonsphericity, rotation and magnetic fields in the collapse of N % NJ. The formation of protostars from the fragmentation of clouds of mass M % MJ due to the residual perturbations that survive for N « NJ is also investigated. K ok : HYDRODYNANICS - STARS-POPULATION III

  1. Development cooperation in water and sanitation: is it based on the human rights framework?

    PubMed

    Brown, Colin; Heller, Léo

    2017-07-01

    The water and sanitation sector is verifiably receiving increased attention and funding through international development cooperation. Not least because of the way that it affects incentives and institutions in partner countries, development cooperation can have either positive or negative effects on human rights though. The consolidated frameworks for the human rights to water and sanitation is becoming linked to the international community's coordinated development efforts, as evidenced notably in the 2030 Agenda for Sustainable Development. However, a review of major funders' official policies for development cooperation in the sector suggests that many only partially endorse the frameworks for the human rights to water and sanitation. An observation of development cooperation flows to the sector allows the hypothesis to be advanced that worldwide inequalities in access to these services may be reduced through a full and clear application of the human rights framework in development cooperation activities. The article presents findings of this research and explores key stakes for development cooperation in the water and sanitation sector that are relevant for their ability to either negatively or positively contribute to the realization of human rights. Resumen El sector de agua y saneamiento ha recibido creciente atención y financiación a través de la cooperación internacional para el desarrollo. La cooperación para el desarrollo puede tener efectos tanto positivos cuanto negativos sobre los derechos humanos. El hito que consolida los derechos humanos al agua y al saneamiento están articulados a esfuerzos de cooperación para el desarrollo promovidos por la comunidad internacional, como se evidencia en la Agenda 2030 para el Desarrollo Sostenible. Sin embargo, una revisión de las políticas oficiales de los principales financiadores del sector sugiere que muchos de ellos aprueban solo parcialmente los hitos de los derechos humanos al agua y el saneamiento. La observación de los flujos de esta cooperación para el sector permite formular la hipótesis de que las desigualdades en el acceso a estos servicios en diferentes partes del mundo pueden reducirse con la aplicación completa y clara del marco de los derechos humanos en las actividades de cooperación para el desarrollo. El artículo presenta los resultados de esta investigación y explora los desafíos de la cooperación para el desarrollo del sector de agua y aguas residuales que son relevantes para impactar tanto negativamente cuanto positivamente a los derechos humanos.

  2. [Not Available].

    PubMed

    Peñailillo Escarate, Luis; Mackay Phillips, Karen; Serrano Duarte, Natalia; Canales Espinoza, Pablo; Miranda Herrera, Pamela; Zbinden-Foncea, Hermann

    2016-07-19

    Introducción: el entrenamiento de intervalos de alta intensidad (HIIT) y el consumo de ácidos grasos omega-3 (O3) ha demostrado cada uno por separado aumentar la capacidad aeróbica, metabolismo oxidativo y función cardiovascular.Objetivo: examinar el efecto combinado de HIIT más suplementación de O3 en el rendimiento físico, presión arterial y composición corporal en jóvenes sedentarios.Método: 28 jóvenes sedentarios con sobrepeso (Edad=22 ± 4 años; IMC=25.8 ± 2.4 kg·m-2) fueron distribuidos aleatoriamente en cuatro grupos: grupo O3/HIIT (n=7) realizó un protocolo de HIIT, tres veces por semana durante seis semanas y consumió 2 g·día-1 de O3; grupo HIIT (n=7) realizó solo el HIIT; grupo O3 (n=7) solo consumió O3; y grupo CONTROL (n=7) que no realizó ninguna intervención. Consumo de oxígeno peak (VO2peak), velocidad máxima (Vmax), presión arterial sistólica y diastólica (PAS y PAD), y porcentaje de grasa fueron medidos antes y después de la intervención.Resultados: el consumo de oxígeno peak aumentó más en el grupo O3/HIIT (+10.9%) en comparación con HIIT, O3 y CONTROL. Velocidad máxima aumentó en O3/HIIT (+7.1%) y HIIT (+11.9%). La presión arterial sistólica disminuyó más en O3 (-6.8%) en comparación con O3/HIIT, HIIT y CONTROL. Por último, O3/HIIT (-19.2%), HIIT (-20.2%), y O3 (-15.2%) presentaron mayores disminuciones del porcentaje de masa grasa en relación al CONTROL.Conclusión: nuestros resultados sugieren un efecto potenciador de la capacidad aeróbica máxima producto de la combinación de HIIT y suplementación de O3. Además, se observó una disminución de masa grasa en todos los grupos intervenidos.

  3. Are Japanese groups more competitive than Japanese individuals? A cross-cultural validation of the interindividual-intergroup discontinuity effect.

    PubMed

    Takemura, Kosuke; Yuki, Masaki

    2007-02-01

    The interindividual-intergroup discontinuity effect is the tendency for relationships between groups to be more competitive than the relationships between individuals. It has been observed robustly in studies conducted in the United States, which is a society characterized as "individualistic." In this study, it was explored whether the effect was replicable in a "collectivistic" society such as Japan. From the traditional view in cross-cultural psychology, which emphasizes the collectivistic nature of East Asian peoples, it was expected that the discontinuity effect would be greater in Japan than in the United States. On the other hand, based on recent empirical findings suggesting that North Americans are no less group-oriented than East Asians, it was expected that the discontinuity effect would be no greater in Japan than in the United States. One hundred and sixty Japanese university students played a 10-trial repeated prisoner's dilemma game: 26 sessions of interindividual and 18 sessions of intergroup. Following exactly the procedure of prior experiments in the US, individuals and groups were allowed face-to-face communication with their opponents before making their decisions, and participants in the intergroup condition were further allowed to converse freely with their in-group members. Results replicated previous findings in the United States; groups made more competitive choices than did individuals. In addition, neither the magnitude of the discontinuity effect, nor the frequency of competitive choices made by the groups, were larger in Japan than they were in the majority of prior studies conducted in the United States. These findings suggest cross-cultural robustness of the interindividual-intergroup discontinuity effect. Also, interestingly, they contradict the simple distinction between individualism and collectivism. Implications for studies of culture and group processes are discussed. This research was supported by grants from the Center for the Study of Cultural and Ecological Foundations of the Mind, a 21(st) Century Center of Excellence Program at Hokkaido University. The authors would like to thank Dr. Laura Hernández-Guzmán, three anonymous reviewers, and Robin Cooper, Mark H. B. Radford, and Paul A. Wehr for their helpful comments on earlier versions of this article. They would also like to thank Dr. Chester A. Insko for his kind and valuable advice during the planning of this experiment as well as the interpretation of its results, Kaori Akaishi for her help with data collection, and, finally, colleagues at Hokkaido University who helped to recruit potential participants from their classes. L'effet de discontinuité entre les individus et entre les groupes est la tendance des relations entre les groupes à être plus compétitives que les relations entre les individus. Cet effet fut fermement démontré dans des études menées aux États-Unis, une société caractérisée d' «individualiste». Dans la présente étude, nous avons exploré dans quelle mesure l'effet était applicable à une société «collectiviste» comme le Japon. À partir du point de vue traditionnel de la psychologie interculturelle, laquelle met l'emphase sur la nature collectiviste des peuples de l'Asie de l'Est, il était attendu que l'effet de discontinuité allait être plus grand au Japon qu'aux États-Unis. D'un autre côté, se basant sur les données empiriques récentes qui suggèrent que les Nord-américains ne sont pas moins orientés vers le groupe que les Asiatiques de l'Est, il était attendu que l'effet de discontinuité ne serait pas plus important au Japon qu'aux États-Unis. Cent soixante étudiants universitaires japonais ont pris part à un jeu de dilemme de prisonnier de 10 essais répétés: 26 sessions entre individus et 18 sessions entre groupes. Suivant exactement la procédure des expériences menées précédemment aux États-Unis, les individus et les groupes avaient la permission de communiquer face-à-face avec leur opposant avant de prendre leur décision. De plus, les participants de la condition entre groupes avaient également la possibilité de converser librement avec les membres de leur propre groupe. Les résultats se sont révélés semblables à ceux des études antérieures réalisées aux États-Unis; les groupes ont fait des choix plus compétitifs que les individus. En outre, ni la magnitude de l'effet de discontinuité, ni la fréquence des choix compétitifs faits par les groupes n'étaient plus grands chez les Japonais comparativement à la majorité des études antérieures menées aux États-Unis. Ces résultats soutiennent la robustesse interculturelle de l'effet de discontinuité entre les individus et entre les groupes. Aussi, fait intéressant, ils contredisent la simple distinction entre l'individualisme et le collectivisme. Les implications pour des études sur les cultures et les processus de groupe sont discutées. El efecto de discontinuidad entre individuos y entre grupos es la tendencia a que las relaciones entre grupos sean más competitivas que las relaciones entre individuos. Se ha observado con insistencia en estudios conducidos en Estados Unidos, una sociedad caracterizada como "individualista". En el presente estudio, se exploró si el efecto se repetía en una sociedad "colectivista" como la japonesa. Desde la perspectiva tradicional de la psicología trans cultural, que subraya la naturaleza colectivista de los pueblos asiáticos, se esperaba que el efecto de discontinuidad fuese mayor en Japón que en Estados Unidos. Por otra parte, con base en los hallazgos empíricos recientes que sugieren que los estadounidenses no están menos orientados al grupo que los de este asiático, se esperaba que el efecto de discontinuidad no fuera mayor en Japón que en los Estados Unidos. Ciento sesenta estudiantes universitarios japoneses participaron en un juego del dilema de un prisionero de diez ensayos repetidos: veintiséis sesiones entre individuos y diez y ocho entre grupos. Siguiendo exactamente el procedimiento de los experimentos previos en los Estados Unidos, se permitió tanto a los individuos como a los grupos una comunicación cara a cara con sus oponentes antes de tomar sus decisiones, y se permitió a los participantes en la condición entre grupos que conversaran libremente con los miembros de su propio grupo. Los resultados repitieron los hallazgos previos en los Estados Unidos; los grupos hicieron elecciones más competitivas que los individuos. Además, ni la magnitud del efecto de discontinuidad ni la frecuencia de las elecciones competitivas de los grupos, fueron mayores en Japón que en la mayoría de los estudios previos en Estados Unidos. Estos hallazgos sugieren la robustez trans cultural del efecto de discontinuidad entre individuos y entre grupos. También, de manera interesante, contradicen la simple distinción entre individualismo y colectivismo. Se discutieron las implicaciones para los estudios sobre cultura y procesos grupales.

  4. Effectiveness of personalized face-to-face and telephone nursing counseling interventions for cardiovascular risk factors: a controlled clinical trial.

    PubMed

    Vílchez Barboza, Vivian; Klijn, Tatiana Paravic; Salazar Molina, Alide; Sáez Carrillo, Katia Lorena

    2016-08-08

    to evaluate the effect and gender differences of an innovative intervention involving in-person and telephone nursing counseling to control cardiovascular risk factors (arterial hypertension, dyslipidemia, and overweight), improve health-related quality of life and strengthen self-efficacy and social support in persons using the municipal health centers' cardiovascular health program. a randomized controlled clinical trial involving participants randomized into the intervention group who received traditional consultation plus personalized and telephone nursing counseling for 7 months (n = 53) and the control group (n = 56). The study followed the Consolidated Standards of Reporting Trials Statement. women in the intervention group presented a significant increase in the physical and mental health components compared to the control group, with decreases in weight, abdominal circumference, total cholesterol, low-density lipoprotein cholesterol, and the atherogenic index. The effects attributable to the intervention in the men in the intervention group were increased physical and emotional roles and decreased systolic and diastolic pressure, waist circumference, total cholesterol, low-density lipoprotein cholesterol, atherogenic index, cardiovascular risk factor, and 10-year coronary risk. this intervention is an effective strategy for the control of three cardiovascular risk factors and the improvement of health-related quality of life. evaluar efecto y diferencias por sexo de una intervención innovadora "Consejería de Enfermería Personalizada y Telefónica", dirigida al control de factores de riesgo cardiovascular (hipertensión arterial, dislipidemia y sobrepeso) y al mejoramiento de la calidad de vida relacionada con la salud, fortaleciendo la autoeficacia y el apoyo social en personas usuarias del programa de salud cardiovascular de los Centros de Salud Municipales de Concepción. ensayo clínico controlado aleatoriamente y selección aleatoria de participantes; grupo intervención con consulta tradicional más consejería de enfermería personalizada y telefónica durante 7 meses (n=53); y grupo control (n=56); siguiendo la declaración del Consolidated Standards of Reporting Trials. mujeres del grupo intervención, presentaron aumento significativo con respecto al grupo control, en componentes de salud física y mental; disminución de: peso, circunferencia abdominal, colesterol total, colesterol lipoproteínas de baja densidad e índice de aterogenicidad. En hombres del grupo intervención se reflejó como efectos atribuibles a la intervención: 1) aumento en dimensiones del rol físico y emocional; 2) disminución: presión sistólica y diastólica, circunferencia abdominal, colesterol total, colesterol lipoproteínas de baja densidad, índice de aterogenicidad, factor de riesgo cardiovascular y riesgo coronario a 10 años. esta intervención es una estrategia efectiva para el control de tres factores de riesgo cardiovascular y mejoría de calidad de vida relacionada con la salud. avaliar o efeito e as diferenças por sexo de uma intervenção inovadora: o aconselhamento personalizado e por telefone em enfermagem, visando o controle de fatores de risco cardiovascular (hipertensão arterial, dislipidemia e sobrepeso) e a melhora na qualidade de vida relacionada à saúde, fortalecendo a autoeficácia e o apoio social a pessoas que usam o programa de saúde cardiovascular de Centros Municipais de Saúde. ensaio clínico controlado e randomizado, participantes randomizados, grupo de intervenção: consulta tradicional mais aconselhamento personalizado e por telefone em enfermagem por 7 meses (n = 53); e grupo de controle (n = 56); seguindo a declaração Consolidated Standards of Reporting Trials Statement. mulheres do grupo intervenção apresentaram um aumento significativo, em relação ao grupo controle, nos componentes de saúde mental e física, com diminuição do peso, circunferência abdominal, colesterol total, colesterol de lipoproteínas de baixa densidade e índice aterogênico. Em homens do grupo intervenção, os efeitos atribuíveis à intervenção foram: aumentos nos papeis físicos e emocionais, com diminuições na pressão sistólica e diastólica, circunferência abdominal, colesterol total, colesterol de lipoproteínas de baixa densidade, índice aterogênico, fator de risco cardiovascular e risco coronariano em 10 anos. essa intervenção é uma estratégia eficaz para o controle dos três fatores de risco cardiovascular e a melhora da qualidade de vida relacionada à saúde.

  5. Propiedades biomecánicas de la membrana limitante interna tras recibir tratamiento intravítreo con ocriplasmina.

    PubMed

    Vielmuth, Franziska; Schumann, Ricarda G; Spindler, Volker; Wolf, Armin; Scheler, Renate; Mayer, Wolfgang J; Henrich, Paul B; Haritoglou, Christos

    2017-01-01

    Objetivo: Evaluar la rigidez de la membrana limitante interna (MLI) humana y evaluar los posibles cambios de las propiedades mecánicas tras administrar una inyección intravítrea de ocriplasmina para tratar la tracción vitreomacular. Métodos: Este estudio se compone de una serie de casos intervencionales y comparativos de 12 muestras de MLI extraídas mediante cirugía y obtenidas de forma consecutiva de 9 ojos de 9 pacientes después de someterse sin éxito a vitreólisis farmacológica con ocriplasmina. Durante el mismo periodo de tiempo, 16 muestras de otros 13 ojos sin tratamiento con ocriplasmina se obtuvieron mediante vitrectomía y sirvieron como controles. Todos los pacientes presentaron agujeros maculares o tracción vitreomacular y se sometieron a vitrectomía con disección de la MLI tanto con tinción con azul brillante (AB) como sin ella. Todas las muestras se analizaron con un microscopio de fuerza atómica con imágenes de las regiones de 25 × 25 μm. En todas las muestras, se analizaron tanto la parte de la retina como la del vítreo de la MLI. Resultados: La microscopia de fuerza atómica no reveló diferencias significativas en cuanto a elasticidad de las muestras de MLI extraídas de ojos con o sin tratamiento con ocriplasmina. Las áreas onduladas de la parte de la retina presentaron una mayor rigidez que la parte del vítreo de la MLI. La cartografía topográfica tanto de la parte del vítreo como de la retina de la MLI no mostró ninguna alteración aparente de la morfología en ojos tratados con ocriplasmina en comparación con los ojos no tratados. La tinción con azul brillante conllevó un aumento de la rigidez tisular. Conclusiones: Las inyecciones intravítreas de ocriplasmina no varían las propiedades biomecánicas de la MLI humana. No existen pruebas de un posible efecto enzimático que interfiera con la rigidez de esta membrana basal. © 2017 S. Karger AG, Basel.

  6. Induction of sterility in Anastrepha Fraterculus (Diptera: Tephritidae) by gamma radiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Allinghi, A.; Gramajo, C.; Willink, E.

    In relation to the application of the sterile insect technique (SIT) for the South American fruit fly Anastrepha fraterculus (Wiedemann), we analyzed the effect on adult fertility of different doses of gamma irradiation and the age of pupae at the time of irradiation. In a first experiment, we applied doses of 50, 70, and 90 Gy to pupae at 24, 48, 72, and 96 h before adult emergence. In a second experiment we irradiated pupae 48 h before emergence with 20, 40, and 60 Gy and estimated male and female fertility and sperm transfer by irradiated males. The results indicatedmore » pupal age at irradiation does not significantly affect male fertility. If males irradiated with 60 Gy are crossed to non-irradiated females the fertility is about 1%. Females irradiated with 40 Gy did not lay eggs independently of the male to which they mated. No significant effects of radiation were observed with respect to the ability of males to transfer sperm. A dose of 70 Gy applied 48 h before adult emergence induces 100% sterility in both males and females. (author) [Spanish] Para la aplicacion de la tecnica del insecto esteril (TIE) en Anastrepha fraterculus (Wiedemann), en este trabajo analizamos el efecto de diferentes dosis de irradiacion gamma y la edad optima de la pupa al momento de la irradiacion. En el primer experimento se evaluaron las dosis de 50, 70, y 90 Gy en pupas de 24, 48, 72, y 96 h antes de la emergencia del adulto. En el segundo experimento se irradiaron pupas 48 h antes de la emergencia con dosis de 20, 40, 60 Gy y se estimo la fertilidad de los machos y las hembras, y la transferencia de espermas por los machos irradiados. Los resultados indicaron que la irradiacion no modifico significativamente la fertilidad de los machos. En las cruzas de machos irradiados a 60 Gy con hembras no irradiadas se observo 1% de eclosion larvaria, mientras que las hembras irradiadas a 40 Gy no pusieron huevos. La irradiacion no afecto significativamente la transferencia de espermas de los machos tratados. Por lo tanto, una dosis de 70 Gy aplicada 48 h antes de la emergencia del adulto induce 100% de esterilidad tanto en machos como en hembras. (a0011uth.« less

  7. La enumeración de la soltería femenina en los censos de población: sesgo y propuesta de corrección

    PubMed Central

    McCaa, Robert; Esteve, Albert; Garcia, Joan

    2013-01-01

    Esta investigación tiene como objetivo investigar el efecto que la disolución de las uniones consensuales tiene en los niveles de soltería que proporciona el Censo de Población, niveles derivados de la variable estado civil. Para ello comparamos los datos censales con los de la Encuestas de Demografía y Salud (de ahora en adelante DHS) en aquellos países y años para los que disponemos de ambas fuentes en el mismo año o años adyacentes (Bolivia, Brasil, Colombia y Perú). Los resultados muestran claramente que las proporciones de nunca unidas derivadas de la variable censal ’Estado civil’ son sistemáticamente más elevadas que las estimadas a partir de las DHS. La razón de esta sobreestimación obedece al hecho de que personas que estuvieron en unión libre en el pasado se declaran solteras en el momento del Censo. La elevada proporción de mujeres solteras que tienen hijos según el Censo es una prueba de ello y a su vez una solución efectiva para corregir el sesgo. PMID:25593515

  8. Determination of aquifer roof extending under the sea from variable-density flow modelling of groundwater response to tidal loading: case study of the Jahe River Basin, Shandong Province, China

    NASA Astrophysics Data System (ADS)

    Cheng, Jianmei; Chen, Chongxi; Ji, Menrui

    The main task of studies on salt-water intrusion into coastal confined aquifers is to predict the position of the fresh- salt-water interface, which can be determined from the length of the aquifer roof extending under the sea. Records of groundwater level affected by tides can be used to infer hydrological conditions and determine hydraulic parameters of an aquifer extending under the sea. In this paper, a three-dimensional, variable-density groundwater flow model has been developed to determine the equivalent roof length of an aquifer extending under the sea from the tidal-effected data of groundwater level in the Jahe River Basin, Shandong Province, China. The seaward boundary is obtained by converging hydraulic head fluctuations observed in drill holes with calculated values, and the aquifer parameters in the extending zone are estimated. The impacts of aquifer roof length and aquifer parameters on the fluctuation of tidal groundwater are studied. It is concluded that the length of the aquifer roof extending under the sea should correspond with certain aquifer parameters in the extrapolation zone. Therefore, the seaward boundary determined from tidal-effect information is the equivalent boundary in hydrodynamic characteristics rather than the true boundary of the confined aquifer Les sujets principaux des études d'instrusion saline dans les aquifères confinés en zone côtière sont la prédiction de la position de l'interface entre l'eau salée et l'eau fraîche, qui peut être déterminée à partir de l'extention du toit de l'aquifère sous la mer. Les enregistrements des niveaux des eaux souterraines influencés par les marées peuvent être utilisés pour préciser les conditions hydrologiques et déterminer les paramètres hydrauliques d'un aquifère possédant une extension sous la mer. Dans cet article, un modèle tridimensionnel comprenant des eaux souterraines de densité variable a été développé pour déterminer la longueur équivalente du toit d'un aquifère qui s'étend sous la mer à partir des données concernant les effets de marée sur les eaux souterraines dans le bassin de la rivière Jahe, dans la province de Shandong, Chine. La limite de salinité est déterminée en faisant converger les fluctuations des hauteurs piézométriques avec les valeurs calculées, et les paramètres de l'aquifère sont estimés dans la zone s'étendant sous la mer. L'incidence de la longueur de l'aquifère sous la mer sur les fluctuations des niveaux est étudiée. On en conclut que la longueur du toit de l'aquifère sous la mer peut correspondre à certains aquifères paramètres dans la zone d'extrapolation. Par conséquent, la limite de salinité déterminée à partir des effets de marée est l'équivalent d'une limite hydrodynamique plutôt que la véritable limite de l'aquifère. El principal objetivo de los estudios sobre intrusiones de agua salada en acuíferos costeros confinados es predecir la posición de la interfase agua dulce-agua salada, la cual puede determinarse a partir de la longitud del techo del acuífero que se extiende por debajo del mar. Los registros de niveles de agua subterránea afectados por las mareas puede utilizarse para inferir las condiciones hidrológicas y determinar los parámetros hidráulicos de un acuífero que se extiende por debajo del mar. En este artículo se ha desarrollado un modelo de flujo tri-dimensional de agua subterránea de densidad variable para determinar la longitud del techo equivalente de un acuífero que se extiende por debajo del mar a partir de datos, afectados por la marea, de niveles de agua subterránea en la Cuenca del Río Jahe, Provincia Shandong, China. El límite hacia el océano se obtiene por convergencia de fluctuaciones de presiones hidráulicas observadas en pozos con valores calculados, y se estiman los parámetros del acuífero en la zona extendida. Se estudian los impactos de la longitud del techo del acuífero y los parámetros del acuífero en la fluctuación del agua subterránea afectada por las mareas. Se concluye que la longitud del techo del acuífero que se extiende por debajo del mar debería corresponder con ciertos parámetros del acuífero en la zona de extrapolación. Por lo tanto, el límite hacia el océano determinado a partir de información de efectos de marea es el límite equivalente en características hidrodinámicas más que el límite real del acuífero confinado.

  9. Tools for evaluating Lipolexis oregmae (Hymenoptera: Aphidiidae) in the field: Effects of host aphid and host plant on mummy location and color plus improved methods for obtaining adults

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Singh, R.; Hoy, M.A.

    Lipolexis oregmae Gahan was introduced into Florida in a classical biological control program directed against the brown citrus aphid, Toxoptera citricida (Kirkaldy), on citrus. Prior to evaluating distribution, host range, and potential nontarget effects of L. oregmae in Florida, we evaluated the role of other potential host aphids and host plants on mummy production and location. Under laboratory conditions, this parasitoid produced the most progeny on the target pest, the brown citrus aphid on citrus. This parasitoid, unlike the majority of aphidiids, did not produce mummies on any of the host plants tested when reared in black citrus aphid T.more » aurantii (Boyer de Fonscolombe) on grapefruit, spirea aphid Aphis spiraecola Patch on grapefruit and pittosporum, cowpea aphid A. craccivora Koch on grapefruit and cowpeas, or melon aphid A. gossypii Glover on grapefruit and cucumber. Thus, sampling for L. oregmae mummies of these host aphids and host plants must involve holding foliage in the laboratory until mummies are produced. This parasitoid requires high relative humidity to produce adults because no adults emerged when mummies were held in gelatin capsules, but high rates of emergence were observed when mummies were held on 1.5% agar plates. In addition, we compared the color of 6 aphid hosts and the color of mummies produced by L. oregmae when reared in them to determine if color of mummies could be used to identify L. oregmae . Mummy color varied between aphid hosts and tested host plants, and is not a useful tool for identifying L. oregmae for nontarget effects. (author) [Spanish] Lipolexis oregmae Gahan fue introducida en Florida por medio de un programa de control biologico clasico dirigido contra el afido pardo de los citricos, Toxoptera citricida (Kirkaldy), sobre Citrus. Prioritario a la evaluacion de la distribucion, el rango de los hospederos y los efectos potenciales de L. oregmae sobre los organismos que no son el enfoque de control en la Florida, nosotros evaluamos el papel de otras especies de afidos y plantas hospederas potenciales sobre la produccion y ubicacion de las momias. Bajo condiciones de laboratorio, este parasitoide produjo el mayor numero de progenies sobre la especie de plaga enfocada, el afido pardo de los citricos sobre Citrus . Este parasitoide, no como la mayoria de los afidiidos (Hymenoptera), no produjo momias sobre cualquiera de las plantas hospederas probadas cuando fue criado sobre el afido negro de los citricos, ( T. aurantii (Boyer de Fonscolombe)) en toronja, el afido spirea (Aphis spiraecola Patch) en toronja y pittosporum, el afido del caupi (A. craccivora Koch) en toronja y caupi o el afido del melon (A. gossypii Glover) en toronja y pepino. Asi, el muestreo para momias de L. oregmae de estas especies de afidos hospederos y plantas hospederas tiene que incluir el mantenimiento de follaje en el laboratorio hasta que se produzcan las momias. Este parasitoide requiere una alta humedad relativa para producir los adultos por que ningun adulto emergio cuando las momias fueron mantenidas en capsulas de gelatina, pero una tasa alta de emergencia de adultos fue observada cuando se mantuvo las momias en platos con agar al 1.5%. Ademas de esto, nosotros comparamos el color de 6 especies de afidos hospederos, asi como el color de las momias producidos por L. oregmae cuando fue criado sobre ellos para determinar si se puede usar el color de las momias para la identificacion de L. oregmae . El color de las momias varia entre las especies de afidos hospederos y las plantas hospederas probadas, por lo que no es una herramienta util para la identificacion de L. oregmae o para la evaluacion de su efecto sobre los organismos que no son el enfoque del control. (author)« less

  10. Nonspherical Radiation Driven Wind Models Applied to Be Stars

    NASA Astrophysics Data System (ADS)

    Arauxo, F. X.

    1990-11-01

    ABSTRACT. In this work we present a model for the structure of a radiatively driven wind in the meridional plane of a hot star. Rotation effects and simulation of viscous forces were included in the motion equations. The line radiation force is considered with the inclusion of the finite disk correction in self-consistent computations which also contain gravity darkening as well as distortion of the star by rotation. An application to a typical BlV star leads to mass-flux ratios between equator and pole of the order of 10 and mass loss rates in the range 5.l0 to Mo/yr. Our envelope models are flattened towards the equator and the wind terminal velocities in that region are rather high (1000 Km/s). However, in the region near the star the equatorial velocity field is dominated by rotation. RESUMEN. Se presenta un modelo de la estructura de un viento empujado radiativamente en el plano meridional de una estrella caliente. Se incluyeron en las ecuaciones de movimiento los efectos de rotaci6n y la simulaci6n de fuerzas viscosas. Se consider6 la fuerza de las lineas de radiaci6n incluyendo la correcci6n de disco finito en calculos autoconsistentes los cuales incluyen oscurecimiento gravitacional asi como distorsi6n de la estrella por rotaci6n. La aplicaci6n a una estrella tipica BlV lleva a cocientes de flujo de masa entre el ecuador y el polo del orden de 10 de perdida de masa en el intervalo 5.l0 a 10 Mo/ano. Nuestros modelos de envolvente estan achatados hacia el ecuador y las velocidads terminales del viento en esa regi6n son bastante altas (1000 Km/s). Sin embargo, en la regi6n cercana a la estrella el campo de velocidad ecuatorial esta dominado por la rotaci6n. Key words: STARS-BE -- STARS-WINDS

  11. Interactive effects of water diversion and climate change for juvenile chinook salmon in the lemhi river basin (USA.).

    PubMed

    Walters, Annika W; Bartz, Krista K; McClure, Michelle M

    2013-12-01

    The combined effects of water diversion and climate change are a major conservation challenge for freshwater ecosystems. In the Lemhi Basin, Idaho (U.S.A.), water diversion causes changes in streamflow, and climate change will further affect streamflow and temperature. Shifts in streamflow and temperature regimes can affect juvenile salmon growth, movement, and survival. We examined the potential effects of water diversion and climate change on juvenile Chinook salmon (Oncorhynchus tshawytscha), a species listed as threatened under the U.S. Endangered Species Act (ESA). To examine the effects for juvenile survival, we created a model relating 19 years of juvenile survival data to streamflow and temperature and found spring streamflow and summer temperature were good predictors of juvenile survival. We used these models to project juvenile survival for 15 diversion and climate-change scenarios. Projected survival was 42-58% lower when streamflows were diverted than when streamflows were undiverted. For diverted streamflows, 2040 climate-change scenarios (ECHO-G and CGCM3.1 T47) resulted in an additional 11-39% decrease in survival. We also created models relating habitat carrying capacity to streamflow and made projections for diversion and climate-change scenarios. Habitat carrying capacity estimated for diverted streamflows was 17-58% lower than for undiverted streamflows. Climate-change scenarios resulted in additional decreases in carrying capacity for the dry (ECHO-G) climate model. Our results indicate climate change will likely pose an additional stressor that should be considered when evaluating the effects of anthropogenic actions on salmon population status. Thus, this type of analysis will be especially important for evaluating effects of specific actions on a particular species. Efectos Interactivos de la Desviación del Agua y el Cambio Climático en Individuos Juveniles de Salmón Chinook en la Cuenca del Río Lemhi (E.U.A.). Conservation Biology © 2013 Society for Conservation Biology No claim to original US government works.

  12. Physiological adaptation of maternal plasma volume during pregnancy: a systematic review and meta-analysis.

    PubMed

    de Haas, S; Ghossein-Doha, C; van Kuijk, S M J; van Drongelen, J; Spaanderman, M E A

    2017-02-01

    To describe the physiological pattern of gestational plasma volume adjustments in normal singleton pregnancy and compare this with the pattern in pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction. We performed a meta-analysis of the current literature on plasma volume adjustments during physiological and complicated pregnancies. Literature was retrieved from PubMed (NCBI) and EMBASE (Ovid) databases. Included studies reported both reference plasma volume measurements (non-pregnant, prepregnancy or postpartum) and measurements obtained during predetermined gestational ages. Mean differences bet ween the reference and pregnancy plasma volume measurements were calculated for predefined intervals of gestational age using a random-effects model described by DerSimonian and Laird. Thirty studies were included in the meta-analysis with publication dates ranging from 1934 to 2007. Plasma volume increased in the first weeks of pregnancy, with the steepest increase occurring during the second trimester. Plasma volume continued to increase in the third trimester with a pooled maximum increase of 1.13 L (95% CI, 1.07-1.19 L), an increase of 45.6% (95% CI, 43.0-48.1%) in physiological pregnancies compared with the reference value. The plasma volume expansion in gestational hypertensive and growth-restricted pregnancies was 0.80 L (95% CI, 0.59-1.02 L), an increase of 32.3% (95% CI, 23.6-41.1%) in the third trimester, a smaller increase than in physiological pregnancies (P < 0.0001). During physiological pregnancy, plasma volume increases by, on average, more than 1 L as compared with non-pregnant conditions. In pregnancies complicated by pregnancy-induced hypertension, pre-eclampsia or fetal growth restriction, plasma volume increase in the third trimester is 13.3% lower than in normal pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. Adaptación fisiológica del volumen del plasma materno durante el embarazo: una revisi\\xF3n sistemática y metaanálisis RESUMEN OBJETIVO: Describir el patrón fisiológico de los cambios en el volumen del plasma gestacional en embarazos normales con feto único y compararlo con el patrón en los embarazos complicados por hipertensión gestacional, preeclampsia o restricción del crecimiento fetal. MÉTODOS: Se realizó un metaanálisis de la literatura actual sobre los cambios en el volumen de plasma durante embarazos complicados y fisiológicos. La literatura se obtuvo de las bases de datos PubMed (NCBI) y EMBASE (Ovid). Los estudios incluidos mencionaban tanto mediciones de referencia del volumen plasmático (no embarazada, antes del embarazo o después del parto) como mediciones tomadas a edades gestacionales predeterminadas. Se calcularon las medias de las diferencias entre las mediciones de referencia y las del embarazo para el volumen plasmático a intervalos predefinidos de la edad gestacional, utilizando un modelo de efectos aleatorios descrito por DerSimonian y Laird. En el metaanálisis se incluyeron treinta estudios con fechas de publicación entre 1934 y 2007. El volumen plasmático aumentó en las primeras semanas de embarazo y el mayor incremento se produjo durante el segundo trimestre. El volumen de plasma continuó aumentando en el tercer trimestre con un aumento combinado máximo de 1,13L (IC 95%, 1,7-1,19 L), lo que supone un aumento del 45,6% (IC 95%, 43,0-48,1%) en embarazos fisiológicas en comparación con el valor de referencia. El aumento del volumen plasmático en los embarazos con hipertensión y con crecimiento intrauterino restringido fue de 0,80L (IC 95%, 0,59-1,02 L), lo que supone un aumento del 32,3% (IC 95%, 23,6-41,1%) en el tercer trimestre, y un incremento menor que en los embarazos fisiológicos (P <0,0001). Durante el embarazo fisiológico el volumen de plasma aumenta, en promedio, más de 1L, en comparación con el de las no embarazadas. En los embarazos complicados por hipertensión gestacional, preeclampsia o restricción del crecimiento fetal, el aumento del volumen plasmático en el tercer trimestre es un 13,3% menor que en el embarazo normal. :meta : ,、。 : meta。PubMed(NCBI)EMBASE(Ovid)。(、)。DerSimonianLaird,。 : Meta30,19342007。,。,1.13 L(95% CI,1.07~1.19 L),,45.6%(95% CI,43.0%~48.1%)。0.80 L(95%CI,0.59~1.02 L),32.3%(95% CI,23.6%~41.1%),(P<0.0001)。 : ,,1 L。、,13.3%。. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  13. La inserción en el mercado laboral de los inmigrantes latinos en España y en los Estados Unidos: Diferencias por país de origen y estatus legal

    PubMed Central

    Connor, Phillip; Massey, Douglas

    2013-01-01

    Resumen Este artículo compara los resultados económicos entre los inmigrantes latinoamericanos en España y Estados Unidos. Detectamos un efecto de selección por el que la mayoría de los inmigrantes latinoamericanos en España proceden de Sudamérica de un entorno de clases medias, mientras la mayoría de los inmigrantes que van a los Estados Unidos son centroamericanos de clase baja. Este efecto de selección explica las diferencias transnacionales en la probabilidad de empleo, logro ocupacional y salarios obtenidos. A pesar de las diferencias en los orígenes y las características de los latinoamericanos en ambos países, los factores demográficos, humanos y de capital social parecen operar de forma similar en ambos países; y cuando los modelos se estiman separadamente por estatus legal, descubrimos que los efectos se acentúan más entre los inmigrantes irregulares cuando se los compara con los regulares, especialmente en Estados Unidos. PMID:24532857

  14. Genetic analysis of maternal ability in Iberian pigs.

    PubMed

    Rodriguez, C; Rodrigañez, J; Silio, L

    1994-01-12

    A practical measure of milk yield of the sow is the weight of the litter at three weeks of age when the piglet growth is entirely dependent on the milking ability of the dam. Genetic parameters of litter size at birth (LS) and litter weight at 21 days (LW21) were estimated using a DFREML procedure from records of 4883 litters (2,049 for LW21) of Iberian breed. Preliminary analysis showed negligible maternal genetic effects. The model for both traits included the fixed effects of farrowing period (86 levels), parity (6) and inbreeding coefficients of dam (Fd) and litter (F(1) ) as co-variables, and three random effects-additive genetic value, permanent environmental effect and residual on both traits. Heritability and repeatability estimates were 0.064 and 0.126 (LS) and 0.163 and 0.270 (LW21) respectively. Estimated genetic and phenotypic correlations were 0.214 and 0.043. The inbreeding depression per 10 % increase of Fd or F(1) was -0.150 or -0.170 in live piglets and -0.983 or -1.023 kg of litter weight. When the model for LW21 included the dam inbreeding and the number of suckling piglets as co-variables, the heritability and repeatability estimates were 0.243 and 0.431 respectively. A complementary analysis was carried out on individual records (weight at 21 days) of 26206 piglets farrowed by 1317 sows. The model included the fixed effects of sex, farrowing period, parity, and the inbreeding coefficients of dam and individual, as co-variables. A total of four random effects were also included: direct and maternal genetic effects, common environmental effects and residual. Estimates of heritability, maternal heritability and common environmental coefficient were, respectively, 0.019, 0.163 and 0.128, reinforcing the evidence of genetic variance for milk producing ability in Iberian sows. The estimated values of inbreeding depression for piglet weight at 21 days were -0.072 and -0.098 kg per 10 % increase in dam or litter inbreeding. ZUSAMMENFASSUNG: Genetische Analyse von Muttereigenschaften iberischer Schweine Ein praktisches Maß für Milchleistung von Sauen ist das Drei-Wochen-Wurfgewicht, das völlig von der Muttermilchleistung abhängt. Genetische Parameter für Geburtswurfgröße (LS) und Geburtswurfgewicht bei 21 Tagen (LW21) wurden mit DFREML von 4883 Würfen (2049 für LW21) geschätzt. Vorläufige Analysen zeigten vernachläßigbare maternale Wirkungen. Das Modell enthält fixe Wirkungen der Wurfperiode (86), Wurffolge (6) und Inzuchtkoeffizienten von Muttersau (Fd) und Wurf (F(1) ) als Ko-variable und dazu drei zufällige Wirkungen: additiv-genetischer Wert, permanenter Umwelteinfluß und der Rest, bei beiden Merkmalen. Heritabilität und Wiederholbarkeit wurden auf 0,064 und 0,126 (LS) und auf 0,163 und 0,270 (LW21) geschätzt. Genetische und phänotypische Korrelationen waren 0,214 bzw. 0,043. Inzuchtdepression pro 10 % für Fd bzw. Fl waren -0,15 bzw. -0,17 bei lebenden Ferkeln und -0,983 bzw. -1,023 Kg in Wurfgewicht. Wenn im Modell für LW21 Mutterinzucht und Zahl saugender Ferkel berücksichtigt wurde, waren die Heritabilitäts- und Wiederholbarkeitsschätzungen 0,243 und 0,431. Eine komplementäre Analyse wurde für Einzelgewichte bei 21 Tagen an 26206 Ferkel von 1317 Sauen durchgeführt. Das Modell enthält festgesetzte Wirkungen von Geschlecht, Wurfperiode, Wurffolge und Inzuchtkoeffizient von Mutter und Ferkel sowie vier zufällige Wirkungen: direkte und maternale Wirkungen, gemeinsame Umweltwirkungen und den Rest. Schätzwerte für Heritabilität, maternale Heritabilität und Wurfumwelt waren 0,019, 0,163 bzw. 0,128, was auf genetische Varianz bei Milchleistung iberischer Sauen hinweist. Die geschätzten Werte für Inzucht-depression für Drei-Wochen-Ferkelgewicht waren -0,072 und -0,098 pro 10% Inzuchtsteigerung von Muttersau und Wurf. RESUMEN: Análisis genético de la aptitud maternal en cerdos ibéricos Una medida práctica de la capacidad lechera de la cerda es el peso de la camada con tres semanas cuando el crecimiento del lechón depende exclusivamente de la producción lechera de la madre. Mediante el procedimiento DFREML se han estimado parámetros genéticos para el tamaño de camada al nacimiento (LS) y peso de la camada a 21 dias (LW21) a partir de 4883 camadas (2049 para LW21) de cerdos Ibéricos. Análisis preliminares mostraron la inexistencia de efectos genéticos maternales significativos sobre ambos caracteres. El modelo ha incluido el efecto fijo de la paridera (86 niveles), orden de parto (6) y los coeficientes de consanguinidad de la madre (Fd) y de la camada (Fl) como covariables, y tres efectos aleatorios: valor genético aditivo, ambiente permanente y residuo. La heredabilidad y repetibilidad estimadas fueron 0,064 y 0,126 (LS) y 0,163 y 0,270 (LW21). Las correlaciones genética y fenotipica fueron 0,214 y 0,043. La depresión consanguinea por 10 % de aumento de Fd o Fl fue -0,150 y -0,170 lechones vivos para LS y -0,983 y - 1,023 kg para LW21. Cuando el modelo para LW21 incluyó como covariables la consanguinidad de la madre y el número de lechones criados, la heredabilidad y repetibilidad estimadas fueron 0,243 y 0,431. Se efectuó un análisis complementario mediante un modelo con efectos maternos de registros de peso a 21 dias de 26206 lechones nacidos de 1317 cerdas. Las estimas de heredabilidad, heredabilidad maternal y coeficiente de ambiente común de camada fueron 0,019, 0,163 y 0,128 respectivamente, reforzando la evidencia de variabilidad genética para la aptitud lechera en cerdas Ibéricas. Los valores de depresión consanguinea estimados para el peso del lechón a 21 dias fueron -0,072 y -0,098 kg por 10 % de aumento de consanguinidad de la madre o del individuo. 1994 Blackwell Verlag GmbH.

  15. Concepciones Alternativas de "Fotosintesis" en estudiantes Universitarios del curso basico de Biologia y posibles correcciones con el Modelo Educativo MODEF

    NASA Astrophysics Data System (ADS)

    De Jesus Roman, Sandra

    Concepciones Alternativas de Fotosíntesis en estudiantes Universitariosdel curso básico de Biología y posibles correcciones con el Modelo Educativo MODEF El modelo educativo para la enseñanza de Fotosíntesis (MODEF) se implantó para trabajar el problema de las concepciones alternativas (CA) en un curso de Biología General. Se evaluaron los resultados en cuanto al logro del aprendizaje significativo. La pregunta central de la investigación fue: ¿Cómo aporta el modelo educativo en la didáctica y comprensión del tema de fotosíntesis? Se efectuó una investigación acción con una fase cuantitativa y una cualitativa. Para la fase cuantitativa se elaboró una prueba para determinar las concepciones alternativas, se validó y se sometió a los estudiantes que participaron en el estudio antes y después de ofrecer la unidad de metabolismo celular. Los participantes eran estudiantes de primer año de la Universidad de Puerto Rico en Bayamón (UPRB). Se llevó a cabo un análisis de consistencia interna de la prueba mediante el método Alfa de Cronbach. Se analizaron las contestaciones a cada pregunta mediante la prueba de Ji cuadrado de contingencia, se efectuó la prueba de t y el coeficiente r de Pearson. La fase cualitativa incluyó la observación participativa de la investigadora- profesora, las reflexiones de los estudiantes y la información de las entrevistas semi-estructuradas que se realizaron a tres estudiantes del curso. El análisis se llevó a cabo mediante el Modelo de Wolcott. Se trabajaron diez CA de las cuales siete fueron corregidas mediante el Modelo MODEF. Las actividades más importantes para el proceso de aprendizaje incluyeron el trabajo de investigación o búsqueda de información para hacer una presentación digital, la elaboración de tablas, los mapas de conceptos, el uso de visuales o videos y las analogías para explicar conceptos o procesos. En conclusión: se recomienda el uso del Modelo MODEF para la discusión del tema de Fotosíntesis a base de los resultados cuantitativos y cualitativos de esta investigación. El Comité Institucional para la Protección de los Seres Humanos en la Investigación (CIPSHI) autorizó el estudio.

  16. Use of black vulture (Coragyps atratus) in complementary and alternative therapies for cancer in Colombia: A qualitative study

    PubMed Central

    2012-01-01

    Background Although Coragyps atratus has been used as a traditional therapy for patients with cancer, the scientific literature does not contain enough information on how this therapy is used or the mechanisms that explain this therapeutic practice. Objectives To understand the methods of use and the reasons given by patients and caregivers for the use of Coragyps atratus in cancer treatment. Methods This study used a qualitative design based on twenty in-depth interviews of patients with cancer or caregivers of patients with the disease. The analysis of the text was based on an inductive thematic approach. Results Resistance to disease and immune enhancement are properties attributed to Coragyps atratus when used for cancer treatment. The most recommended method of use is fresh blood ingestion, and the associated mechanism of action is transfer of immune factors to the individual who consumes it. Conclusions Use of Coragyps atratus as a treatment for cancer is a popular alternative therapy in Colombia. More studies are needed to understand the clinical effects of this intervention in cancer patients. Spanish abstract Introducción Aunque Coragyps atratus se usa tradicionalmente como terapia para pacientes con cáncer, no existe suficiente información en la literatura científica sobre su forma de utilización ni sobre los mecanismos explicativos que subyacen a esta práctica terapéutica. Objetivos Conocer métodos de utilización y mecanismos explicativos dados por los pacientes y cuidadores de pacientes sobre el uso de Coragyps atratus en el tratamiento del cáncer. Materiales y métodos Diseño cualitativo basado en veinte entrevistas en profundidad de pacientes con cáncer o cuidadores de pacientes con esta enfermedad. Análisis de texto basado en enfoque temático inductivo. Resultados Al Coragyps atratus se le atribuyen propiedades de resistencia y fortalecimiento del sistema inmune de personas enfermas de cáncer. La forma de utilización mas común es la ingesta de la sangre fresca y el mecanismo de acción asociado es la transferencia de defensas a quien lo consume. Conclusiones La utilización del Coragyps atratus como tratamiento para el cáncer es una terapia alternativa usada popularmente en Colombia. El uso de este animal debe estudiarse más a fondo para conocer los efectos clínicos en los pacientes con cáncer. PMID:22651097

  17. Global Analysis of Anthropogenic Debris Ingestion by Sea Turtles

    PubMed Central

    Schuyler, Qamar; Hardesty, Britta Denise; Wilcox, Chris; Townsend, Kathy

    2014-01-01

    Ingestion of marine debris can have lethal and sublethal effects on sea turtles and other wildlife. Although researchers have reported on ingestion of anthropogenic debris by marine turtles and implied incidences of debris ingestion have increased over time, there has not been a global synthesis of the phenomenon since 1985. Thus, we analyzed 37 studies published from 1985 to 2012 that report on data collected from before 1900 through 2011. Specifically, we investigated whether ingestion prevalence has changed over time, what types of debris are most commonly ingested, the geographic distribution of debris ingestion by marine turtles relative to global debris distribution, and which species and life-history stages are most likely to ingest debris. The probability of green (Chelonia mydas) and leatherback turtles (Dermochelys coriacea) ingesting debris increased significantly over time, and plastic was the most commonly ingested debris. Turtles in nearly all regions studied ingest debris, but the probability of ingestion was not related to modeled debris densities. Furthermore, smaller, oceanic-stage turtles were more likely to ingest debris than coastal foragers, whereas carnivorous species were less likely to ingest debris than herbivores or gelatinovores. Our results indicate oceanic leatherback turtles and green turtles are at the greatest risk of both lethal and sublethal effects from ingested marine debris. To reduce this risk, anthropogenic debris must be managed at a global level. Análisis Global de la Ingesta de Residuos Antropogénicos por Tortugas Marinas La ingesta de residuos marinos puede tener efectos letales y subletales sobre las tortugas marinas y otros animales. Aunque hay investigadores que han reportado la ingesta de residuos antropogénicos por tortugas marinas y la incidencia de la ingesta de residuos ha incrementado con el tiempo, no ha habido una síntesis global del fenómeno desde 1985. Por esto analizamos 37 estudios publicados, desde 1985 hasta 2012, que reportan datos colectados desde antes de 1900 y a lo largo del 2011. Investigamos específicamente si el predominio de la ingesta ha cambiado con el tiempo, qué tipos de residuos se ingieren comúnmente, la distribución geográfica de la ingesta de residuos por tortugas marinas en relación a la distribución global de residuos y cuáles especies y etapas de vida tienen más probabilidad de ingerir residuos. La probabilidad de que las tortugas verdes (Chelonia mydas) y laúd (Dermochelys coriacea) ingieran escombros incrementa significativamente con el tiempo; plástico fue el residuo que más se ingirió. Las tortugas en casi todas las regiones estudiadas ingieren residuos, pero la probabilidad de ingesta no estuvo relacionada con las densidades modeladas de residuos. Además de esto, tortugas más pequeñas, en etapa oceánica de vida, tuvieron una mayor probabilidad de ingerir residuos que las tortugas forrajeras terrestres, mientras que las especies carnívoras tuvieron menos probabilidad de ingerir residuos que las herbívoras o las gelatinívoras. Nuestros resultados indican que las tortugas verdes y laúd tienen el mayor riesgo de efectos letales y subletales de la ingesta de residuos marinos. Para reducir el riesgo, los residuos antropogénicos deben manejarse en un nivel global. PMID:23914794

  18. [In Process Citation].

    PubMed

    Alarcón Hormazábal, Manuel; Delgado Floody, Pedro; Castillo Mariqueo, Lidia; Thuiller Lepelegy, Nicole; Bórquez Becerra, Pablo; Sepúlveda Mancilla, Carlos; Rebolledo Quezada, Sara

    2016-03-25

    Introducción: existe una alta prevalencia de sedentarismo, sobrepeso y obesidad en jóvenes universitarios. Objetivo: el propósito del estudio fue determinar los efectos de un programa de entrenamiento intervalado de alta intensidad (HIIT) sobre el perfil antropométrico, glicemia basal y VO 2 máx (consumo máximo de oxígeno) de jóvenes sedentarios con malnutrición por exceso. Material y métodos: 6 mujeres y 2 hombres (2 obesos y 6 con sobrepeso) se sometieron a un programa de entrenamiento de alta intensidad de 8 semanas de duración (3 sesiones/semana). Se evaluó en ayuno y posterior a 72 horas de la última intervención; peso, índice de masa corporal (IMC), contorno de cintura (CC), perímetro de cadera y glicemia de basal. El VO 2 máx fue evaluado en condiciones normales previo a la primera sesión. Resultados: las variables de estudio no presentaron cambios significativos (p > 0,05), pero reportaron disminuciones porcentuales. El peso disminuyó un 0,18%, el IMC un 0,27%, el CC 2,67%, el perímetro de cadera un 1,15%, y el VO 2 máx un 0,48%. La glicemia basal presentó la mayor disminución, pasó de 95,13 ± 23,91 a 89,88 ± 12,45 mg/dl (5,52%), estabilizando y mejorando sus niveles en cada uno de los participantes. Conclusiones: el programa de entrenamiento intervalado de alta intensidad fue factible de realizar sin resultados adversos para la salud de los participantes, la glicemia basal mostró la mayor variación, estabilizando sus valores en los participantes, lo que es un indicador positivo dentro del programa. Es necesario seguir investigando sobre esta metodología HIIT y aumentar los tiempos de estudio para ver los cambios que se pueden producir en distintos parámetros metabólicos, antropométricos y físicos en población con malnutrición por exceso.

  19. [Not Available].

    PubMed

    MIján de la Torre, Alberto

    2016-06-03

    El síndrome de caquexia cancerosa es responsable de la muerte de un número significativo de pacientes con cáncer. Se caracteriza por la presencia de una ingesta reducida, con inflamación sistémica y un metabolismo alterado. Los enfermos presentan característicamente una progresiva pérdida de peso y de masa muscular, junto a deterioro funcional. La pérdida muscular se debe a la combinación de reducción de la síntesis proteica con aumento de su degradación. Ello conduce tanto a un acortamiento como a una reducción en el área de la fibra muscular. Asimismo, existen datos que apoyan que selectivamente algunos de los tipos de fibra muscular se ven más afectados. Es necesario definir bien los valores de corte de sarcopenia para diagnosticar la pérdida muscular y existen diferentes métodos. El sistema de la ubiquitina-proteasoma parece desempeñar un papel predominante en la degradación de la proteína miofibrilar. La tendencia a perder masa muscular en los pacientes con caquexia cancerosa parece estar asociada a la activación de señales catabólicas por citoquinas proinflamatorias, así como por productos tumorales del tipo factor inductor de proteólisis. En referencia a los factores pronósticos, el riesgo de muerte está bien documentado en pacientes con sarcopenia y, especialmente, en aquellos con obesidad asociada a la sarcopenia. Asimismo, se ha establecido una relación directa entre la pérdida intensa de masa muscular y la supervivencia en pacientes con diferentes tipos de tumores del tipo de cáncer de páncreas, pulmón, tracto biliar o cáncer colorrectal. Respecto de la terapia en el síndrome de caquexia cancerosa, es factible que requiera tratamiento con varios grupos combinados que incluyan, junto al soporte nutricional, fármacos orexígenos, con efecto anabólico y antinflamatorio, asociados a intervenciones que estimulen el ejercicio físico.

  20. Combined effects of climate change and bank stabilization on shallow water habitats of chinook salmon.

    PubMed

    Jorgensen, Jeffrey C; McClure, Michelle M; Sheer, Mindi B; Munn, Nancy L

    2013-12-01

    Significant challenges remain in the ability to estimate habitat change under the combined effects of natural variability, climate change, and human activity. We examined anticipated effects on shallow water over low-sloped beaches to these combined effects in the lower Willamette River, Oregon, an area highly altered by development. A proposal to stabilize some shoreline with large rocks (riprap) would alter shallow water areas, an important habitat for threatened Chinook salmon (Oncorhynchus tshawytscha), and would be subject to U.S. Endangered Species Act-mandated oversight. In the mainstem, subyearling Chinook salmon appear to preferentially occupy these areas, which fluctuate with river stages. We estimated effects with a geospatial model and projections of future river flows. Recent (1999-2009) median river stages during peak subyearling occupancy (April-June) maximized beach shallow water area in the lower mainstem. Upstream shallow water area was maximized at lower river stages than have occurred recently. Higher river stages in April-June, resulting from increased flows predicted for the 2080s, decreased beach shallow water area 17-32%. On the basis of projected 2080s flows, more than 15% of beach shallow water area was displaced by the riprap. Beach shallow water area lost to riprap represented up to 1.6% of the total from the mouth to 12.9 km upstream. Reductions in shallow water area could restrict salmon feeding, resting, and refuge from predators and potentially reduce opportunities for the expression of the full range of life-history strategies. Although climate change analyses provided useful information, detailed analyses are prohibitive at the project scale for the multitude of small projects reviewed annually. The benefits of our approach to resource managers include a wider geographic context for reviewing similar small projects in concert with climate change, an approach to analyze cumulative effects of similar actions, and estimation of the actions' long-term effects. Efectos Combinados del Cambio Climático y la Estabilización de Bordes de Ríos Hábitats de Aguas Poco Profundas del Salmón Chinook. Conservation Biology © 2013 Society for Conservation Biology No claim to original US government works.

  1. Genetic Variation of Methylenetetrahydrofolate Reductase (MTHFR) and Thymidylate Synthase (TS) Genes Is Associated with Idiopathic Recurrent Implantation Failure.

    PubMed

    Choi, Youngsok; Kim, Jung Oh; Shim, Sung Han; Lee, Yubin; Kim, Ji Hyang; Jeon, Young Joo; Ko, Jung Jae; Lee, Woo Sik; Kim, Nam Keun

    2016-01-01

    The one-carbon metabolism pathway disorder was important role in successful pregnancy. The MTHFR and TS protein were crucial factor in one-carbon metabolism. To investigate the association between recurrent implantation failure (RIF) and enzymes in the one-carbon metabolism pathway. A total of 120 women diagnosed with RIF and 125 control subjects were genotyped for MTHFR 677C>T, 1298A>C, TSER 2R/3R and TS 1494del/ins by a polymerase chain reaction-restriction fragment length polymorphism assay. According to the gene-gene combination analysis, the MTHFR 677/MTHFR 1298 (TT/AA) and MTHFR 677/TS 1494 (TT/6bp6bp) genetic combinations were associated with relatively higher risks [adjusted odds ratio (AOR), 2.764; 95% CI, 1.065-7.174; P = 0.037 and AOR, 3.186; 95% CI, 1.241-8.178; P = 0.016] in RIF patients compared to the CC/AA (MTHFR 677/MTHFR 1298) and TT/6bp6bp (MTHFR 677/TS 1494) combinations, respectively. The results suggested that the combined MTHFR 677/MTHFR 1298 genotype might be associated with increased risk of RIF. To the best of our knowledge, this study is the first to elucidate the potential association of MTHFR, TS and TSER polymorphisms with RIF risk in Korean patients.

  2. Contaminación por mercurio de leche materna de madres lactantes de municipios de Antioquia con explotación minera de oro.

    PubMed

    Molina, Carlos Federico; Arango, Catalina María; Sepúlveda, Hernán

    2018-05-01

    Introducción. La leche materna es esencial para el desarrollo del ser humano, pero puede contener sustancias tóxicas provenientes de la contaminación ambiental, especialmente en las áreas mineras.Objetivo. Determinar la prevalencia de la contaminación con mercurio de la leche materna de mujeres lactantes residentes en los municipios con explotación minera de oro.Materiales y métodos. Se hizo un estudio transversal de 150 madres lactantes de cuatro municipios mineros de Antioquia (El Bagre, Segovia, Remedios y Zaragoza), a quienes se les hizo una encuesta sobre factores sociodemográficos, ocupacionales y ambientales relacionados con el mercurio, y se les tomaron muestras de leche materna, de orina y de cabello. Se calculó el promedio de la concentración de mercurio y las prevalencias municipales de contaminación.Resultados. El promedio de la concentración de mercurio en la leche materna fue de 2,5 (± desviación estándar 9,2) μg/L. La prevalencia de muestras de leche materna con niveles altos de mercurio fue de 11,7 %.Conclusión. En este estudio se evidencia un grave problema en las regiones mineras auríferas de Antioquia por el efecto de la contaminación con mercurio en sectores de la población más vulnerable.

  3. Análisis del futuro marco de referencia internacional

    NASA Astrophysics Data System (ADS)

    Cionco, G. R.; Arias, E. F.

    La técnica de interferometría de muy larga línea de base (VLBI) se aplica hoy a la astrometría para el cálculo de posiciones precisas de radiofuentes extragalácticas. Por tratarse de objetos lejanos, sus movimientos propios aparentes pueden considerarse nulos; esta propiedad hace que los catálogos de radiofuentes extragalácticas VLBI constituyan la mejor materialización de un sistema de referencia celeste inercial definido cinemáticamente. La Unión Astronómica Internacional (IAU) recomendó la adopción de un nuevo sistema de referencia celeste internacional materializado por las coordenadas ecuatoriales de objetos extragalácticos observados con le técnica VLBI. Para superar la precisión astrométrica actual es necesaria una mejora en la modelización de aquellos fenómenos que pueden introducir desviaciones sistemáticas en el marco de referencia celeste. El objetivo de este trabajo es poner de manifiesto las sistematicidades presentes en los distintos marcos de referencia elaborados con el próposito de materializar el nuevo sistema de referencia celeste de la IAU. Para la comparación de los distintos marcos de referencia se propone un modelo de tres rotaciones diferenciales más un término lineal que procura absorber los efectos sistemáticos presentes en las coordenadas. Se analiza igualmente la estabilidad de la solución cuando se utilizan distintos conjuntos de objetos de definición.

  4. Capture-zone design in an aquifer influenced by cyclic fluctuations in hydraulic gradients

    NASA Astrophysics Data System (ADS)

    Zawadzki, Willy; Chorley, Don; Patrick, Guy

    2002-10-01

    Design of a groundwater pumping and treatment system for a wood-treatment facility adjacent to the tidally influenced Fraser River estuary required the development of methodologies to account for cyclic variations in hydraulic gradients. Design of such systems must consider the effects of these cyclic fluctuations on the capture of dissolved-phase contaminants. When the period of the cyclic fluctuation is much less than the travel time of the dissolved contaminant from the source to the discharge point, the hydraulic-gradient variations resulting from these cycles can be ignored. Capture zones are then designed based on the average hydraulic gradient determined using filter techniques on continuous groundwater-level measurements. When the period of cyclic fluctuation in hydraulic gradient is near to or greater than the contaminant travel time, the resulting hydraulic-gradient variations cannot be ignored. In these instances, procedures are developed to account for these fluctuations in the capture-zone design. These include proper characterization of the groundwater regime, assessment of the average travel time and period of the cyclic fluctuations, and numerical techniques which allow accounting for the cyclic fluctuations in the design of the capture zone. Résumé. L'étude d'un système de pompage et de traitement de l'eau souterraine d'une usine de traitement du bois proche de l'estuaire de la rivière Fraser, influencé par les marées, a nécessité la mise au point de méthodologies pour prendre en compte les variations cycliques de gradients hydrauliques. L'étude de tels systèmes doit considérer les effets de ces variations cycliques sur l'extraction des contaminants en phase dissoute. Lorsque la période des variations cycliques est très inférieure au temps de parcours du contaminant dissous entre la source et le point d'émergence, les variations du gradient hydraulique résultant de ces cycles peuvent être ignorées. Les zones d'extraction sont alors réalisées sur la base du gradient hydraulique moyen déterminé au moyen de techniques de filtrage sur des mesures continues de la piézométrie. Lorsque la période de la fluctuation cyclique dans le gradient hydraulique est proche de ou supérieure au temps de parcours du contaminant, les variations résultantes de gradient hydraulique ne peuvent plus être ignorées. Dans ces cas-là, des procédures ont été mises au point pour prendre en compte ces fluctuations dans la conception de la zone d'extraction. Celles-ci prennent en considération la caractérisation propre du régime de la nappe, l'évaluation du temps de parcours moyen et de la période des fluctuations cycliques, et des techniques numériques qui permettent de considérer les fluctuations cycliques dans la conception de la zone d'extraction. Resumen. El diseño de un sistema de bombeo y tratamiento de aguas subterráneas para una instalación de manufactura de madera que está próxima al estuario del río Fraser, sometido a la influencia de las mareas, ha requerido el desarrollo de metodologías para tener en cuenta las variaciones cíclicas de los gradientes hidráulicos. El diseño de tales sistemas debe considerar los efectos de las fluctuaciones cíclicas en la captura de contaminantes en fase disuelta. Cuando el período de la fluctuación cíclica es mucho menor que el tiempo de tránsito del contaminante disuelto entre el punto de entrada y el de descarga, se puede ignorar las variaciones del gradiente hidráulico provocadas por dichos ciclos. Las zonas de captura se diseñan entonces en función del gradiente hidráulico promedio, que se determina mediante técnicas de filtrado de medidas continuas del nivel piezométrico. Cuando el período de la fluctuación cíclica del gradiente hidráulico es comparable o mayor que el tiempo de tránsito del contaminante, no puede ignorarse las variaciones resultantes en el gradiente hidráulico. En ese caso, se tiene que desarrollar procedimientos para contar con las fluctuaciones en el diseño de las zonas de captura. Ello implica una adecuada caracterización del régimen de las aguas subterráneas, el establecimiento del tiempo de tránsito y del período de las fluctuaciones cíclicas, y el uso de técnicas numéricas que permitan incluirlas en el diseño de la zona de captura.

  5. Complications of central venous catheter in patients transplanted with hematopoietic stem cells in a specialized service.

    PubMed

    Barretta, Lidiane Miotto; Beccaria, Lúcia Marinilza; Cesarino, Cláudia Bernardi; Pinto, Maria Helena

    2016-06-07

    to identify the model, average length of stay on site and complications of central venous catheter in patients undergoing transplant of hematopoietic stem cells and verify the corresponding relationship between the variables: age, gender, medical diagnosis, type of transplant, implanted catheter and insertion site. a retrospective and quantitative study with a sample of 188 patients transplanted records between 2007 and 2011. the majority of patients used Hickman catheter with an average length of stay on site of 47.6 days. The complication fever/bacteremia was significant in young males with non-Hodgkin's lymphoma undergoing autologous transplant, which remained with the device for a long period in the subclavian vein. nurses should plan with their team the minimum waiting time, recommended between the catheter insertion and start of the conditioning regimen, as well as not to extend the length of time that catheter should be on site and undertake their continuing education, focusing on the prevention of complications. identificar o modelo, tempo médio de permanência e complicações de cateter venoso central em pacientes submetidos ao transplante de células-tronco hematopoiéticas e verificar a relação de correspondência entre as variáveis: idade, sexo, diagnóstico médico, tipo de transplante, cateter implantado e local de inserção. retrospectivo, quantitativo, com amostra de prontuários de 188 pacientes transplantados, entre 2007 e 2011. a maioria dos pacientes utilizou o cateter de Hickman com permanência média de 47,6 dias. A complicação febre/bacteremia foi significante em jovens do sexo masculino, com linfoma não Hodgkin, submetidos ao transplante autólogo, que permaneceram com o dispositivo por longo período, em veia subclávia. os enfermeiros devem planejar com a equipe o aguardo do tempo mínimo preconizado entre o implante do cateter e início do regime de condicionamento, assim como não estender o período de permanência e realizar educação permanente, enfocando a prevenção das complicações. identificar el modelo, el tiempo medio de permanencia y las complicaciones del catéter venoso central en pacientes sometidos a trasplante de células madre hematopoyéticas y estimar la relación de correspondencia entre las variables: edad, sexo, diagnóstico médico, tipo de trasplante, catéter implantado y sitio de inserción. estudio retrospectivo y cuantitativo con una muestra de registros de 188 pacientes trasplantados entre 2007 y 2011. la mayoría de los pacientes utilizó el catéter Hickman con una permanencia media de 47,6 días. La complicación fiebre/bacteriemia fue significativa en los varones jóvenes con linfoma no Hodgkin sometidos a trasplante autólogo, que permanecieron con el dispositivo durante un largo período en la vena subclavia. los enfermeros deben planificar con el equipo, el tiempo de espera mínimo recomendado entre la inserción del catéter y el inicio del tratamiento de condicionamiento, así como no extender el período de permanencia del catéter y realizar su formación continua, centrándose en la prevención de complicaciones.

  6. ¿Qué es un repelente de insectos?

    EPA Pesticide Factsheets

    Según la ley de pesticidas, estos productos son cualquier sustancia o mezcla de sustancias destinadas a lo siguiente: prevenir; eliminar; repeler; mitigar cualquier peste. (Mitigar significa reducir el efecto de algo).

  7. Evolución de planetas gigantes y posibilidades de su detección directa

    NASA Astrophysics Data System (ADS)

    Brunini, A.; Benvenuto, O. G.

    Desde la reciente detección de planetas gigantes orbitando estrellas cercanas de tipo solar por medio de efecto Doppler, uno de los principales problemas, en cuanto al estudio de los sistemas planetarios extrasolares, se refiere a la posibilidad de obtener evidencia directa de su existencia. Esto parece ser factible gracias a que en un futuro cercano entrarán en operación algunos telescopios especialmente adecuados a estos propósitos. Por tal motivo, hemos comenzado desde hace un tiempo un esfuerzo en cuanto al estudio de la evolución planetaria. A tales efectos hemos adaptado el código de evolución estelar de nuestro Observatorio al caso planetario. Las principales diferencias entre el caso estelar y el planetario se encuentran en la ecuación de estado. A tales fines hemos incluído la reciente ecuación de estado de Saumon, Chabrier y Van Horn, las opacidades radiativas de Guillot et al., procesos de quema de Deuterio, etc. También se ha considerado la posible existencia de fases de hielo y roca en el interior planetario. Por el momento hemos despreciado los efectos de la rotación planetaria. Con este código hemos computado la evolución de planetas con masas desde 10 hasta 0.3 masas de Júpiter. Utilizando nuestros resultados numéricos discutimos la detectabilidad de estos objetos en condiciones realistas.

  8. Mating opportunities in Sangalopsis veliterna females: Costs and benefits

    PubMed Central

    Hernández Duran, Linda C.; Fajardo Medina, Gonzalo E.; Fuentes Quinter, Luz S.; Martin, Oliver

    2014-01-01

    Abstract In nature, females of several animal taxa exhibit considerable variation in their mating system, and this variation involves different balances of costs (e.g., energetic, reproductive) and benefits (e.g., increased net reproductive rate of the female, increased longevity). Many studies have focused on discovering the potential advantages and disadvantages that females could have when increasing their mating rate and the possible evolutionary consequences that may result. Butterflies and moths are an ideal study system because it is easy to determine and to manipulate experimentally their mating frequency. In this study, the effect of continuous availability of different numbers of males (1, 2, 4, 8) on female mating rate and fitness components was estimated by comparing the number of spermatophores in the corpus bursa (an estimate of the number of copulations, but not of the number males involved in these copulations), female longevity, lifetime number of laid eggs (fecundity), and proportion of hatching eggs (fertility) in the moth Sangalopsis veliterna Druce (Lepidoptera: Geometridae). The results showed that there were no significant differences in either fertility or fecundity when treatments were compared, but longevity and in some cases fecundity increased when females had several matings. Resumen En la naturaleza, hembras de varios taxa animal muestran una variación considerable en su sistema de apareamiento, esta variación involucra diferentes costos (energéticos, reproductivos, etc) y beneficios (aumento de la tasa reproductiva neta de la hembra, mayor longevidad, entre otros). En años recientes, muchos estudios se han enfocado en descubrir las potenciales ventajas y desventajas que las hembras podrían tener al aumentar su número de cópulas y las posibles consecuencias evolutivas que podrían resultar. Las mariposas y polillas son un sistema de estudio ideal, dada la facilidad para determinar y manipular experimentalmente su frecuencia de apareamiento. En este estudio, el efecto de la disponibilidad continua de diferente número de machos (1, 2, 4, 8) sobre la frecuencia de apareamiento de las hembras y los componentes del potencial reproductivo (fitness) fueron estimados al comparar el número de espermatóforos hallados en la bursa copulatrix (un estimado del número de copulas, pero no del número de machos involucrados en estas copulas), la longevidad de las hembras, número de huevos colocados (fecundidad) y proporción de huevos fecundados (fertilidad) en la polilla Sangalopsis veliterna Druce (Lepidóptera: Geometridae). Los resultados indican que no existen diferencias en la fertilidad ni en la fecundidad; sin embargo la longevidad aumentó a medida que se las hembras presentaron más de una cópula y de igual manera en algunos casos la fecundidad aumentó con varios apareamientos. PMID:25205137

  9. Alfabetización en Astronomía de docentes de Educación Primaria y de Educación Secundaria en La Plata

    NASA Astrophysics Data System (ADS)

    De Biasi, M. S.; Orellana, R. B.

    2014-10-01

    La educación de este siglo tiene como uno de sus retos alcanzar la alfabetización cientfica de todos los ciudadanos para que comprendan y tomen decisiones sobre el mundo natural y sus cambios originados por la actividad humana utilizando el conocimiento científico. En esta misión los docentes de los niveles obligatorios de enseñanza juegan un papel clave por su rol de agentes multiplicadores del conocimiento. Se requiere, entonces de una adecuada alfabetización en ciencias de los docentes o, como mínimo, que dominen los temas científicos a enseñar. En el campo de la Astronomía, numerosas investigaciones han señalado que maestros de primaria y estudiantes de profesorados poseen una escasa formación en estos temas (Camino 1995 y 1999, Gangui 2010), que frecuentemente presentan a los alumnos concepciones alternativas o no científicas de los fenómenos astronómicos cotidianos (Kriner 2004, Vega Navarro 2007, Gangui et al 2010); a lo que se suma la presentación confusa o errónea de algunos temas astronómicos en los textos escolares (Kriner 2004). Desde 2011, la Facultad de Ciencias Astronómicas y Geofísicas, UNLP, ofrece un curso de capacitación destinado a fortalecer y actualizar los contenidos académicos y didácticos de los docentes del distrito La Plata utilizando diversas estrategias didácticas. Los contenidos comprenden los temas astronómicos de los diseños curriculares vigentes. La evaluación diagnóstica de los conocimientos previos de los docentes cursantes sobre los contenidos de mayor presencia en los diseños curriculares mostró resultados similares a las investigaciones arriba mencionadas. Referente a los movimientos de la Tierra, en promedio, el 54% poseía conceptos erróneos y el 16% no los sabía; con referencia a la Luna el 56% poseía conceptos erróneos y un 4% no los sabía. Los resultados del curso mostraron que el 95% de los docentes revirtió sus conceptos previos erróneos, que adquirió criterios para la búsqueda de fuentes de información confiables y que el grado de conocimientos disciplinares y didácticos alcanzados por los docentes garantiza el efecto multiplicador de esta propuesta. Esta capacitación fue acreditada con puntaje por el organismo educativo provincial en 2011, 2012 y 2013.

  10. Poblacion estelar joven embebida en la nube molecular galactica asociada a la fuente IRAS 18236-1205

    NASA Astrophysics Data System (ADS)

    Romero, Ricardo Retes

    2008-06-01

    En esta tesis presento una metodología de seleccion y estudio de la población estelar embebida en la nube molecular galactica asociada a la fuente IRAS 18236-1205. La fuente IRAS posee colores de region Ultra Compacta HII (UCHII) y tiene deteccióon en monosulfuro de carbono (CS), trazador molecular de alta densidad, lo cual da la posibilidad de definir la nube molecular asociada hacia esta region. Lo anterior muestra que esta es buena candidata a región de formación estelar masiva. La metodología de seleccion de la población embebida, est à basada por una parte, en la distribución del gas molecular monoxido de carbono (13CO) asociado a la fuente IRAS, nube molecular seleccionada del mapeo Galactic Ring Survey (GRS) realizado en 13CO. Otros pasos de la seleccion, se basan en los diagramas color-color y color-magnitud con datos del cercano infrarrrojo de 2MASS. Para el estudio de la componente estelar se usaron los catalogos de fuentes puntuales en el cercano, medio y lejano infrarrojo de 2MASS, SPITZER e IRAS, respectivamente. De los diagramas color-color y color-magnitud, usando datos de 2MASS, se construyo un criterio fotométrico para identificar los objetos estelares j ovenes embebidos en la region molecular. Aplicando modelos a la distribución espectral de energía (SED) de algunos ellos, se encontraron parametros estelares de objetos estelares j ovenes embebidos de masa intermedia y alta. Adicionalmente, se encontro un objeto de masa ´ intermedia no identifiado por el catalogo de 2MASS y su efecto sobre el medio interestelar, emision en la banda de [4.5] μm de IRAC-Spitzer asociado a un outflow. Dos de los objetos seleccionados por el criterio fotometrico resultaron ser objetos estelares jovenes de alta e intermedia masa (B1V/B2V y B8V/A0V respectivamente), los cuales deben estar asociados a la emision radiativa responsable de los colores de región UC HII. Otro objeto estelar joven de baja masa (F0V/F5V) fue encontrado en la region de estudio. Este parece estar asociado con la presencia de un disco circumestelar y material excitado por choque (IRAC-Spitzer [4.5]μm). Se concluye que el escenario de region de formación estelar masiva factible para esta region molecular es el de una asociación estelar joven embebida en una densa región molecular (AV . 30) hacia la fuente IRAS 18236-1205.

  11. Male courtship behavior in Ceratitis Capitata (Diptera: Tephritidae) that have received Aromatherapy with ginger root oil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Briceno, D.; Eberhard, W.; Smithsonian Tropical Research Institute

    The results of previous studies that showed that exposing mass-reared male Mediterranean fruit flies Ceratitis capitata (Wiedemann) to ginger root oil ('aromatherapy') increases the likelihood of mating with wild females were confirmed. The increased male success could be due to female responses to changes in male behavior or male pheromones. There were no significant differences in the types of courtship movements executed by males with and without aromatherapy. The durations of movements also did not differ when mass-reared males were paired with mass-reared females; however, when they were paired with wild females, there were a few, small differences. Previous studiesmore » indicated that the effectiveness of the male long-distance attractant pheromone is not affected by aromatherapy, but these studies did not consider pheromones released at close range during courtship, which behavioral analyses suggest may be different. We propose the following possible explanation for the different effects of aromatherapy with different females. Selection on males under mass rearing may have altered their close-range pheromones in ways that can be remedied by aromatherapy; and only wild females respond because the pheromonal responsiveness of mass-reared females has also changed. We propose observations that could test these ideas. (author) [Spanish] Los resultados de estudios previos que muestran que al exponer machos criados en masa de la mosca mediterranea de la fruta Ceratitis capitata (Wiedemann) al aceite de la raiz del jengibre ('aromaterapia') aumento la probabilidad del apareamiento con hembras naturales fueron confirmados. El aumento en el exito de los machos puede ser debido a las respuestas de las hembras a los cambios en el comportamiento o feromonas de los machos. No hubo una diferencia significativa en la clase de los movimientos del cortejo ejecutados por los machos con y sin la aromaterapia. La duracion de los movimientos tampoco fue diferente cuando los machos criados en masa fueron apareados con hembras criadas en masa; sin embargo, cuando ellos fueron apareados con hembras naturales, resultaron unas pequenas diferencias. Los estudios previos indicaron que la eficacia de la feromona atrayente de machos de larga distancia no esta afectada por la aromaterapia, pero estos estudios no consideran las feromonas sueltas en un rango corto durante el cortejo, cuando el analisis de comportamiento sugiere que puede ser diferente. Nosotros proponemos la explicacion siguiente para los efectos diferentes de la aromaterapia con las diferentes hembras. La seleccion de machos bajo condiciones de cria en masa puede haber alterado las feromonas de rango corto de manera que puede ser remediada por la aromaterapia; y solamente las hembras naturales responden por que tambien ha cambiado la respuesta de las hembras criadas en masa a la feromona. Nosotros indicamos observaciones que pueden probar estas ideas. (author)« less

  12. Simulation of groundwater drainage into a tunnel in fractured rock and numerical analysis of leakage remediation, Romeriksporten tunnel, Norway

    NASA Astrophysics Data System (ADS)

    Kitterød, N.-O.; Colleuille, H.; Wong, W. K.; Pedersen, T. S.

    2000-09-01

    Standard geostatistical methods for simulation of heterogeneity were applied to the Romeriksporten tunnel in Norway, where water was leaking through high-permeable fracture zones into the tunnel while it was under construction, causing drainage problems on the surface. After the tunnel was completed, artificial infiltration of water into wells drilled from the tunnel was implemented to control the leakage. Synthetic heterogeneity was generated at a scale sufficiently small to simulate the effects of remedial actions that were proposed to control the leakage. The flow field depends on the variance of permeabilities and the covariance model used to generate the heterogeneity. Flow channeling is the most important flow mechanism if the variance of the permeability field is large compared to the expected value. This condition makes the tunnel leakage difficult to control. The main effects of permeability changes due to sealing injection are simulated by a simple perturbation of the log-normal probability density function of the permeability. If flow channeling is the major transport mechanism of water into the tunnel, implementation of artificial infiltration of water to control the leakage requires previous chemical-sealing injection to be successful. Résumé. Des méthodes géostatistiques standard ont été employées pour simuler l'hétérogénéité des zones de fractures à fortes perméabilitées dans lesquelles, au cours de la construction du tunnel ferroviaire de Romeriksporten (Norvège), l'eau s'est écoulée, causant des problèmes de drainage en surface. Quand les travaux ont été terminés, l'injection d'eau dans des puits forés à partir du tunnel a été réalisée pour contrôler ces infiltrations. Une hétérogénéité synthétique a été créée à une échelle suffisamment petite pour simuler les effets de l'injection d'eau. Le champ des écoulements dépend de la variance des perméabilités et de la covariance du modèle utilisé pour générer l'hétérogénéité. La chenalisation de l'écoulement est le mécanisme d'écoulement le plus important si la variance du champ de perméabilité est grande par rapport à la valeur moyenne. Cette condition fait que les infiltrations dans le tunnel sont difficiles à contrôler. L'étanchéification du tunnel par des produits chimiques est simulé par une simple perturbation de la fonction de densité de probabilité log-normale de la perméabilité. Si la chenalisation de l'écoulement est le principal mécanisme de transport d'eau entrant dans le tunnel, la création d'une injection artificielle de l'eau pour contrôler l'infiltration dans le tunnel impose, pour réussir, une imperméabilisation préalable par des produits chimiques. Resumen. Se han aplicado métodos estadísticos convencionales para la simulación de la heterogeneidad en el túnel de Roeriksporte (Noruega), donde la presencia de agua en zonas fracturadas de alta permeabilidad originó problemas de drenaje en superficie durante su construcción. Una vez finalizado el túnel, para controlar la infiltración se inyectó agua en los pozos situados en su interior. La generación del campo heterogéneo se realizó a una escala lo suficientemente pequeña que permitiera simular los efectos de las medidas de control propuestas. El campo de flujo depende de la varianza de las permeabilidades y del modelo de covarianza utilizado para generar la heterogeneidad. El flujo a través de canales es el mecanismo dominante si la varianza del campo de permeabilidad es grande en relación con el valor esperado. Este hecho condiciona que las filtraciones en el túnel sean difíciles de controlar. Los principales efectos de los cambios de permeabilidad originados por las inyecciones para el sellado del túnel se simularon mediante una simple perturbación de la función de densidad de probabilidad lognormal de la permeabilidad. Si el flujo a través de canales es el principal mecanismo de la presencia de agua en el túnel, el control de las filtraciones mediante técnicas de inyección de agua en pozos de recarga requiere de la inyección previa de un producto químico para el sellado de las fisuras.

  13. Los incendios y su salud

    EPA Pesticide Factsheets

    El humo de los incendios puede tener un efecto adverso en la salud de las personas, especialmente en aquellas que padecen de enfermedades cardíacas y pulmonares. Vea cómo minimizar su exposición al humo.

  14. INTERVENCIÓN EDUCATIVA EFECTIVA EN VIH PARA MUJERES

    PubMed Central

    Miner, Sarah; Poupin, Lauren; Bernales, Margarita; Ferrer, Lilian; Cianelli, Rosina

    2016-01-01

    RESUMEN En Chile se estima que aproximadamente 38 mil personas viven con el Virus de Inmunodeficiencia Humana [VIH]. En el año 2001, 1.092 mujeres chilenas vivían con VIH, actualmente se cree que hay más de 7.600 mujeres con el virus. Frente a estas cifras surge la necesidad de crear estrategias de prevención dirigidas a mujeres chilenas. Objetivo analizar los estudios ya realizados en la prevención de VIH para determinar qué aspectos se deben incluir en programas exitosos de prevención de VIH en mujeres. Diseño y Método se realizó una revisión de la literatura utilizando la base de datos Proquest, CINAHL, Pubmed y Scielo. Los límites comprendieron: textos completos, de los últimos 10 años, de acceso gratuito y escrito en español o inglés. Se seleccionaron 15 artículos para la revisión. Resultados todos los artículos comprenden la evaluación del efecto de una intervención sobre conocimiento y conductas relacionadas con VIH/SIDA. Catorce muestran resultados significativos en cambios positivos de conducta o conocimientos relacionados con la prevención de VIH. Conclusiones los programas de prevención de VIH en mujeres pueden ser efectivos para lograr cambios de conducta y de conocimiento. Las intervenciones exitosas son aquellas basadas en teorías o modelos de prevención y en cambios de conductas, todas adaptadas a la cultura de la población estudiada. PMID:27667897

  15. Evolución de estrellas enanas blancas de Helio de masa baja e intermedia

    NASA Astrophysics Data System (ADS)

    Althaus, L. G.; Benvenuto, O. G.

    Numerosas observaciones realizadas particularmente en los últimos dos años parecen confirmar que las enanas blancas (EB) de helio de masa baja e intermedia son el resultado de la evolución de sistemas binarios cercanos. Con el objeto de realizar una adecuada interpretación de estos objetos son necesarios modelos de EBs de helio lo más detallado posibles. En este estudio presentamos cálculos detallados de la evolución de EBs de helio con masas entre M=0.1Msolar y M=0.5Msolar a intervalos de 0.05Msolar . Para ello, hemos tenido en cuenta los efectos de temperatura finita mediante un código de evolución estelar lo más actualizado posible. En particular, el transporte de energía es descripto en el marco del nuevo modelo para la convección turbulenta desarrollado por Canuto - Mazzitelli. Además hemos considerado la nueva ecuación de estado para plasmas de helio de Saumon et al. y nuevas opacidades radiativas OPAL. Las pérdidas por neutrinos fueron asimismo tenidas en cuenta. Excepto para las EBs más masivas, nuestros modelos iniciales están ubicados en las cercanías de la correspondiente línea de Hayashi para configuraciones de helio. Nuestros resultados muestran que existe una región prohibida en el diagrama observacional HR donde ninguna EB de helio puede encontrarse. Dicha región es para log{(L/Lsolar )}>= -0.25 and log{Teff} >= 4.45. Hemos encontrado también que los tracks evolutivos en el diagrama HR en el dominio de alta luminosidad (pre - EB) son fuertemente afectados por la eficiencia convectiva y que las pérdidas por neutrinos son importantes en los modelos más masivos. Finalmente hemos analizado la estructura de la zona convectiva externa encontrando que la teoría de Canuto - Mazzitelli conduce a un perfil convectivo muy diferente del dado por cualquier versión de la popular teoría de la mixing length. Si bién este comportamiento es decisivo en el contexto de las inestabilides pulsacionales, los radios y gravedades superficiales de los modelos no son afectados al incluir la nueva teoría de convección.

  16. Preclinical atherosclerosis at the time of pre-eclamptic pregnancy and up to 10 years postpartum: systematic review and meta-analysis.

    PubMed

    Milic, N M; Milin-Lazovic, J; Weissgerber, T L; Trajkovic, G; White, W M; Garovic, V D

    2017-01-01

    Pre-eclampsia (PE) is a pregnancy-specific hypertensive disorder that has been associated with cardiovascular risk factors and vascular changes, such as acute atherosis in placental blood vessels, similar to early-stage atherosclerosis. The objective of this study was to determine whether women with PE have increased atherosclerotic burden, as determined by the carotid intima-media thickness (CIMT), compared with women without PE. We conducted a systematic review and meta-analysis of studies that reported CIMT, a non-invasive, ultrasound-based measure of subclinical atherosclerosis, in women who did vs those who did not have PE. Studies were eligible if they had been conducted during pregnancy or during the first decade postpartum, and if CIMT was measured in the common carotid artery. Studies published before 7 March 2016 were identified through PubMed, EMBASE and Web of Science. Two reviewers used predefined forms and protocols to evaluate independently the eligibility of studies based on titles and abstracts and to perform full-text screening, data abstraction and quality assessment. Heterogeneity was assessed using the I 2 statistic. Standardized mean difference (SMD) was used as a measure of effect size. Fourteen studies were included in the meta-analysis. Seven studies were carried out during pregnancy complicated by PE, 10 were carried out up to 10 years postpartum and three included measurements obtained at both time periods. Women who had PE had significantly higher CIMT than did those who did not have PE, both at the time of diagnosis (SMD, 1.10 (95% CI, 0.73-1.48); P < 0.001) and in the first decade postpartum (SMD, 0.58 (95% CI, 0.36-0.79); P < 0.001). Atherosclerotic load is present at the time of PE and may be a mechanism associated with the disease. Measurement of CIMT may offer an opportunity for the early identification of premenopausal women with atherosclerotic burden after a PE pregnancy. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd. La preeclampsia (PE) es un trastorno hipertensivo específico del embarazo que ha sido asociada con factores de riesgo cardiovascular y cambios vasculares, tales como aterosis aguda en los vasos sanguíneos de la placenta, similares a las primeras etapas de la aterosclerosis. El objetivo de este estudio fue determinar si las mujeres con PE han aumentado la carga aterosclerótica, según lo determinado por el espesor del complejo íntima-media de la arteria carótida (CIMT, por sus siglas en inglés), en comparación con las mujeres sin PE. MÉTODOS: Se realizó una revisión sistemática y un metaanálisis de estudios que reportaron el CIMT, una medida no invasiva de la aterosclerosis subclínica obtenida mediante ecografía, comparando mujeres con PE y mujeres sin ella. Solo se incluyeron estudios llevados a cabo durante el embarazo o durante la primera década después del parto, y en los que se midió el CIMT en la arteria carótida común. Se usaron las bases de datos de PubMed, EMBASE y Web of Science para identificar estudios publicados antes del 7 marzo de 2016. Dos revisores utilizaron formularios y protocolos preestablecidos para evaluar de forma independiente la elegibilidad de los estudios, a partir de los títulos y los resúmenes, y para realizar un cribado del texto completo, un resumen de los datos y una evaluación de calidad. La heterogeneidad se evaluó mediante el test estadístico I 2 . Se usó la diferencia de medias estandarizada (SMD, por sus siglas en inglés) como una medida de la magnitud del efecto. En el metaanálisis se incluyeron catorce estudios. Siete de los estudios se llevaron a cabo durante embarazos complicados por PE, 10 se realizaron hasta 10 años después del parto y tres incluyeron mediciones tomadas en ambos períodos. Las mujeres con PE tuvieron un CIMT significativamente mayor que aquellas que no la tenían, tanto en el momento del diagnóstico (SMD 1,10 (I 95%, 0,73-1,48), P <0,001) como en la primera década después del parto (SMD 0,58 (IC 95%, 0,36-0,79), P <0,001). La carga aterosclerótica está presente en el momento de la PE y podría ser un mecanismo asociado con esta enfermedad. La medición del CIMT puede ofrecer una oportunidad para la identificación temprana de mujeres premenopáusicas con carga aterosclerótica después de un embarazo con PE. : (pre-eclampsia,PE),,,。-(carotid intima-media thickness,CIMT),PEPE,。 : PEPECIMTmeta,CIMT、。:10CIMT。PubMed、EMBASEWeb of Science,201637。,,、。I 2 。(SMD)。 : meta14。7PE,1010,3。PEPE,[SMD,1.10(95% CI,0.73~1.48);P<0.001]10[SMD,0.58(95% CI,0.36~0.79);P<0.001] CIMT。 : PE,。CIMT,PE。. Copyright © 2016 ISUOG. Published by John Wiley & Sons Ltd.

  17. Effects of Wind Energy Development on Nesting Ecology of Greater Prairie-Chickens in Fragmented Grasslands

    PubMed Central

    McNew, Lance B; Hunt, Lyla M; Gregory, Andrew J; Wisely, Samantha M; Sandercock, Brett K

    2014-01-01

    Wind energy is targeted to meet 20% of U.S. energy needs by 2030, but new sites for development of renewable energy may overlap with important habitats of declining populations of grassland birds. Greater Prairie-Chickens (Tympanuchus cupido) are an obligate grassland bird species predicted to respond negatively to energy development. We used a modified before–after control–impact design to test for impacts of a wind energy development on the reproductive ecology of prairie-chickens in a 5-year study. We located 59 and 185 nests before and after development, respectively, of a 201 MW wind energy facility in Greater Prairie-Chicken nesting habitat and assessed nest site selection and nest survival relative to proximity to wind energy infrastructure and habitat conditions. Proximity to turbines did not negatively affect nest site selection (β = 0.03, 95% CI = −1.2–1.3) or nest survival (β = −0.3, 95% CI = −0.6–0.1). Instead, nest site selection and survival were strongly related to vegetative cover and other local conditions determined by management for cattle production. Integration of our project results with previous reports of behavioral avoidance of oil and gas facilities by other species of prairie grouse suggests new avenues for research to mitigate impacts of energy development. Efectos del Desarrollo de la Energía Eólica sobre la Ecología de Anidación de Gallinas de la Gran Pradera en Pastizales Fragmentados Resumen Se calcula que la energía eólica aportará el 20% de las necesidades energéticas de los Estados Unidos para el 2030, pero nuevos sitios para el desarrollo de energía renovable pueden traslaparse con hábitats importantes de poblaciones declinantes de aves de pastizal. La gallina de la Gran Pradera (Tympanuchus cupido) es una especie de ave obligada de pastizal que se pronostica responderá negativamente al desarrollo energético. Usamos un diseño ADCI modificado para probar los impactos del desarrollo de la energía eólica sobre la ecología reproductiva de las gallinas en un estudio de 5 años. Ubicamos 59 y 185 nidos antes y después del desarrollo, respectivamente, de una instalación de energía eólica de 201 MW en el hábitat de anidación de las gallinas y estudiamos la selección de sitio de anidación y la supervivencia de nidos en relación con la proximidad a la infraestructura y las condiciones de hábitat. La proximidad con las turbinas no afectó negativamente a la selección de sitios de anidación (β = -0.3, 95% CI = -0.6–0.1). En su lugar, la selección de sitios de anidación y la supervivencia estuvieron fuertemente relacionadas con la cobertura vegetal y otras condiciones locales determinadas por el manejo de la producción de ganado. La integración de los resultados de nuestro proyecto con reportes previos de la evitación conductual de instalaciones de petróleo y gas por otras especies de pastizales sugiere nuevas vías para que la investigación mitigue los impactos del desarrollo energético. PMID:24628394

  18. Caracterización espectroscópica de hielos de interés atmosférico y astrofísico

    NASA Astrophysics Data System (ADS)

    Escribano, R.

    En años recientes se ha incrementado el estudio de procesos físicos y químicos que tienen lugar en la superficie o el interior de hielos, tanto en medios astrofísicos como en la atmósfera terrestre y en otros cuerpos del sistema solar. Se ha comprobado que las partículas heladas actúan como catalizadores de reacciones químicas, que no ocurrirían en su ausencia. En la atmósfera terrestre, es bien conocida la importancia de partículas de hidratos de ácido nítrico, formando las llamadas nubes estratosféricas polares, en los procesos de destrucción de ozono estratosférico. En hielos astrofísicos, átomos como H, C, N y O pueden adherirse o introducirse en la estructura cristalina o amorfa del hielo, y dar lugar a reacciones de formación de moléculas evitando su barrera de activación. Existen partículas heladas en el medio interestelar formando parte de las llamadas nubes moleculares densas y frías, con valores del orden de 106 átomos de H por cm3 y temperaturas entre 3 y 90 K. Alrededor de protoestrellas, pueden formarse hielos de distinta composición, polares o apolares, en las zonas de alejamiento y temperatura decreciente a partir del núcleo caliente. Por su parte, los cometas están formados por un núcleo de hielo y rocas, sobre el que se encuentran adheridas moléculas gaseosas, y una cola, formada por los gases liberados por efecto del calentamiento debido a la radiación solar incidente. En nuestro sistema solar, los polos de La Tierra y de Marte están cubiertos de hielo, así como la mayoría de los cuerpos externos. Los satélites de Júpiter han sido estudiados detalladamente, y se han encontrado en ellos, y en Tritón (satélite de Neptuno), hielos de moléculas como SON2, CO2, N2, CH4 y otros. Para la caracterización espectroscópica de estos hielos se precisan medidas en el laboratorio, aún conociendo la imposibilidad intrínseca de reproducir exactamente las condiciones en que se formaron y se encuentran en los medios astrofísicos. El montaje experimental requiere un sistema que permita alcanzar bajas presiones y temperaturas, formado usualmente por una cámara en cuyo interior se forman películas de hielo de la composición deseada, depositadas sobre un sustrato inerte. Las películas pueden ser a continuación tratadas por diversas técnicas, tales como irradiación UV, bombardeo con electrones o iones, calentamiento y enfriamiento, etc. Habitualmente todos los procesos se controlan por espectroscopía de infrarrojo. La radiación proveniente de un espectrómetro se hace incidir sobre la muestra y se extrae de la cámara mediante ventanas, y se enfoca posteriormente sobre el detector. En el laboratorio de Física Molecular del Instituto de Estructura de la Materia disponemos de un montaje experimental diseñado para el estudio de partículas de hielo similares a las formadas en las nubes estratosféricas polares de nuestra atmósfera. El montaje es similar al descrito anteriormente, excepto en lo que se refiere a las condiciones de presión y temperatura, que son menos estrictas en nuestros experimentos. La extensión de estas condiciones de trabajo a las requeridas en medios astrofísicos es una posibilidad a discutir. Por otra parte, disponemos de un método de cálculo de estructuras periódicas, basado en el programa SIESTA (acrónimo de Spanish Initiative for Electronic Simulations of Thousands of Atoms), que ha proporcionado excelentes resultados en lo relativo a la determinación de estructuras cristalinas y predicción de su espectro infrarrojo, en los sistemas estudiados hasta la fecha, es decir, los hidratos de ácido nítrico de interés atmosféricos. Su aplicación para el estudio de hielos de relevancia astrofísica podría ser del máximo interés.

  19. The effects of acupressure on labor pains during child birth: randomized clinical trial.

    PubMed

    Mafetoni, Reginaldo Roque; Shimo, Antonieta Keiko Kakuda

    2016-08-08

    to analyze the effects of acupressure on the sanyinjiao point for pregnant women in labor at public maternity wards. single-blind controlled clinical trial, randomly done employing a pragmatic profile. We selected 156 pregnant women in their ≥ 37 week/s, who had cervical dilations of ≥ 4 cm and with two or more contractions in 10 minutes. The pregnant women were randomly divided into three groups at a university hospital in the suburbs of Sao Paulo, Brazil, in order to receive either acupressure treatment, a placebo or participate as part of a control group. The acupressure was applied on the sanyinjiao point during the contractions for 20 minutes. Then the intensity of the pain was evaluated using the Visual Analogue Scale (VAS). The averages for the pain measured using the VAS were not different for the three groups that were a part of the study (p-value=0.0929), however they were less in the acupressure groups immediately after receiving the treatment (p-value=<0.0001). This was also the case where the treatment lasted for 1 hour (p-value=0.0001). This was the case in comparison with placebo and control groups. the use of acupressure on the sanyinjiao point is a useful way to alleviate pain in a non-invasive manner. It can improve the quality of care given to pregnant women in labor. Register: RBR-9mhs8r. analisar os efeitos da acupressão no ponto sanyinjiao sobre a dor na fase ativa do trabalho de parto, em gestantes atendidas em maternidade pública. trata-se de um ensaio clínico controlado e randomizado, simples-cego e de caráter pragmático. Foram selecionadas 156 mulheres com idade gestacional ≥ 37 semanas, dilatação cervical ≥ 4 cm e com duas ou mais contrações em 10 minutos. As gestantes foram divididas aleatoriamente em três grupos em um hospital universitário do interior do estado de São Paulo, Brasil, para receber acupressão, placebo ou participar como controle. A acupressão foi aplicada no ponto sanyinjiao durante as contrações, por 20 minutos, e a intensidade da dor avaliada por meio de uma Escala Analógica Visual (EAV). as médias de dor pela EAV não foram diferentes nos três grupos na admissão (p-valor=0,0929), porém foram menores no grupo de acupressão imediatamente após (p-valor=<0,0001) e com 1 h do tratamento (p-valor=0,0001) ao se comparar com placebo e controle. a acupressão no ponto sanyinjiao se mostrou uma medida útil no alívio da dor, não invasiva e um meio de melhorar a qualidade dos cuidados a parturiente. Registro: RBR-9mhs8r. analizar los efectos de la acupresión, en el punto sanyinjiao, sobre el dolor en la fase activa del trabajo de parto, en embarazadas atendidas en maternidad pública. ensayo clínico controlado y aleatorio, simple ciego y de carácter pragmático. Fueron seleccionadas 156 mujeres con edad gestacional ≥ 37 semanas, dilatación cervical ≥ 4 cm y con dos o más contracciones en 10 minutos. Las embarazadas fueron divididas aleatoriamente en tres grupos en un hospital universitario del interior del estado de Sao Paulo, Brasil, para recibir acupresión, placebo o participar como control. La acupresión fue aplicada en el punto sanyinjiao durante las contracciones, por 20 minutos; la intensidad del dolor fue evaluada por medio de una Escala Analógica Visual (EAV). los promedios del dolor por la EAV no fueron diferentes en los tres grupos en la admisión (valor p=0,0929), sin embargo fueron menores en el grupo de acupresión inmediatamente después (valor p=<0,0001) y también después de 1 hora del tratamiento (valor p=0,0001) al compararse con el placebo y control. la acupresión en el punto sanyinjiao se mostró una medida útil en el alivio del dolor, no invasiva y un medio de mejorar la calidad de los cuidados la parturienta. Registro: RBR-9mhs8r.

  20. [Inhibitive effect of LAK cells induced by dendritic cells on implanted lung cancer in nude mice].

    PubMed

    Gao, Qiu; Li, Jintian; Wang, Siyu; Chen, Shiping; Liu, Wei; Wu, Yilong

    2004-10-20

    To study the inhibitive effect of LAK cells induced by dendritic cells (DCs) on implanted lung adenocarcinoma in nude mice. The lung adenocarcinoma model was constructed in nude mice using the resected samples of lung cancer patient. The lung cancer cell lysate was obtained by free-zing and thrawing cycles. Peripheral blood mononuclear cells (PBMNC) were obtained from venous blood of the same patient, in which the adherent PBMNC fraction was cultured with DCGF, and the non-adherent PBMNC fraction was cultured with rhIL-2. DCs were pulsed with lung cancer cell lysates. And then mature DCs were incubated with LAK cells and the mixed cells were named DC-LAK cells. DC-LAK cells were injected into lung cancer-bearing nude mice to observe the inhibitive effect. The lung adenocarcinoma mo-del was successfully constructed. The average tumor weights of DC-LAK, LAK, DC and saline control groups were 0.47, 1.05, 1.30 and 1.58 g respectively, and the inhibitive rates of DC-LAK, LAK and DC were 70.3%, 33.5% and 17.9% respectively. The antitumor activity of DC-LAK cells was significantly stronger than that of LAK cells (P < 0.05). The results of in vivo experiment show that the antitumor activity of DC-LAK cells is stronger than that of LAK cells, so DC-LAK cells treatment may be a more efficient approach of lung cancer biological therapy. This experiment may provide a foundation for clinical application of DC vaccine.

  1. Influence of biological soil crusts at different successional stages in the implantation of biogeochemical cycles in arid and semiarid zones

    NASA Astrophysics Data System (ADS)

    Gil-Sotres, F.; Miralles, I.; Canton-Castilla, Y.; Domingo, F.; Leiros, M. C.; Trasar-Cepeda, C.

    2012-04-01

    Influence of biological soil crusts at different successional stages in the implantation of biogeochemical cycles in arid and semiarid zones I. Miralles1, F. Gil-Sotres2, Y. Cantón-Castilla3, F. Domingo1, M.C. Leirós2, C. Trasar-Cepeda4 1 Experimental Estation of Arid Zones (CSIC), E-04230 La Cañada de San Urbano, Almería, Spain. 2 Departamento Edafología y Química Agrícola, Grupo de Evaluación de la Calidad del Suelo, Unidad Asociada CSIC, Facultad de Farmacia, Universidad de Santiago de Compostela, E-15782 Santiago de Compostela, Spain. 3 University of Almería, Departamento de Edafología y Química Agrícola, E-04230-La Cañada de San Urbano, Almería, Spain. 4 Departamento Bioquímica del Suelo, IIAG-CSIC, Apartado 122, E-15708 Santiago de Compostela, Spain. Crusts (BSCs) are formed by a close association between soil particles and cyanobacteria, algae, lichens, bryophytes and microfungi in varying proportions. Their habitat is within or immediately on top of the uppermost millimetres of the soil and are the predominant surface cover in arid and semiarid zones. Among the diverse functions developed by BSCs in the ecosystem (hydrology, erosion, soil properties, etc.), one of the most important is its role in nutrient cycling. Within arid and semiarid environments, BSCs have been termed 'mantles of fertility' being considered hotspots of biogeochemical inputs, fixing C, N and P above- and below-ground. However, there are differences in N and C fixation rates between BSCs types. Early successional BSCs, dominated by cyanobacterial species, fix lower quantities of C and N than mature BSCs dominated by lichens. Although the positive effects of BSCs on biogeochemical soil cycles are widely accepted, no previous studies have evaluated the activities of the enzymes involved in C, N and P cycles of BSCs and how they are affected by the successional stage of the BSC. In this work, performed in the Tabernas desert (SE Spain), we studied the hydrolase enzymes involved in C (invertase, CM-cellulase, β-glucosidase), N (urease, BAA-protease, casein-protease) and P (phosphomonoesterase) cycles in BSCs at different successional stages (cyanobacteria represents the first successional stage, lichen Diploschistes diacapsis in an intermediate state and lichen Lepraria crassissima, with the greatest successional state). Our results show that BSCs at lower successional stage enriched the surface geological substrate in hydrolase enzymes to a lesser extent than mature BSCs (Lepraria crassissima), which show the highest values in all enzymatic activities. In contrast, the specific enzyme activities (activity values expressed per unit of carbon) were higher in the BSCs at lower successional stage, decreasing in the direction: cyanobacteria > Diploschistes diacapsis-lichen > Lepraria crassissima-lichen. These results suggest a different role of BSCs depending on their successional stage with regard to the implantation of biogeochemical cycles during the surface substrate colonization. Our conclusions are highly relevant to improve the knowledge of biogeochemical cycles in arid and semiarid areas. Keywords: Biological Soil Crusts, arid ecosystems, hydrolytic enzymes, biochemical activity

  2. Land subsidence caused by groundwater exploitation in Suzhou City, China

    NASA Astrophysics Data System (ADS)

    Chen, Chongxi; Pei, Shunping; Jiao, Jiu Jimmy

    2002-09-01

    Suzhou City, located at the lower reaches of the Yangtze River in southeastern Jiangsu Province, is one of the few cities in China which suffer from severe ground settlement. A research project was carried out to investigate this problem. Geological and hydrogeological studies show that there is a multi-layered aquifer system with three distinct, soft mud layers of marine and lagoonal origins. An examination of historical records of groundwater extraction, water levels, and ground settlement shows that the ground subsidence is associated with the continuously increasing groundwater extraction in the deep, confined aquifer. It is believed that the consolidation of the soft mud layers, especially the third layer which is thick and close to the main pumped aquifer, contributes to the ground settlement. A three-dimensional finite difference numerical model representing the multi-layered aquifer system was developed to study the ground settlement in response to groundwater extraction. By calibrating the model with both the measured groundwater level and ground settlement, the aquifer parameters were estimated. The model outputs fit reasonably well with the observed results, which indicates that the numerical model can reproduce the dynamic processes of both groundwater flow and soil consolidation. The hydraulic conductivity of the third mud layer near the center of the ground settlement has been reduced by over 30% in the last 14 years. The gradual deterioration in the hydraulic conductivity of the mud may have significant adverse effect on the sustainable groundwater resource of the deep confined aquifer, since the recharge from the shallow aquifers through the mud layer is the only source of water to the deep aquifer. An analysis of the spatial distributions of groundwater drawdown and ground settlement shows that the area with maximum drawdown is not necessarily the area with maximum ground settlement due to the occurrence of the soft mud layer. A simple reallocation in pumping rates on the basis of the spatial distribution of the thick mud layer could significantly reduce the ground settlement. Résumé. La ville de Suzhou, située dans la basse vallée du fleuve Yangtsé dans le sud-est de la province de Jiangsu, est l'une des rares villes de Chine qui souffrent cruellement de tassements du sol. Un projet de recherche a été mené pour étudier ce problème. Des études géologiques et hydrogéologiques montrent qu'il existe un système aquifère multicouche constitué de trois niveaux distincts de limons non consolidés d'origine marine et lagunaire. Un examen des historiques des prélèvements d'eau souterraine, des niveaux de nappe et des tassements de sol montrent que la subsidence du sol est associée à des prélèvements continuellement croissants d'eau souterraine dans l'aquifère captif profond. On pense que le compactage des couches limoneuses non consolidées, en particulier de la troisième couche qui est épaisse et proche du principal aquifère pompé, contribue aux tassements du sol. Un modèle numérique aux différences finies en trois dimensions, représentant l'aquifère multicouche, a été réalisé pour étudier les tassements du sol en réponse aux prélèvements d'eau souterraine. Les paramètres de l'aquifère ont été estimés par calibration du modèle au moyen à la fois des niveaux piézométriques et des tassements du sol. Les résultats de la simulation s'ajustent convenablement aux résultats observés, ce qui indique que le modèle numérique peut reproduire les processus dynamiques aussi bien des écoulements souterrains que de compactage du sol. La conductivité hydraulique de la troisième couche de limon non consolidé au voisinage du centre du tassement de sol a été réduit de plus de 30% au cours des 14 dernières années. La dégradation progressive de la conductivité hydraulique du limon peut avoir un effet significatif néfaste sur la pérennité de la ressource en eau souterraine dans l'aquifère captif profond, puisque la recharge à partir des aquifères superficiels au travers de la couche de limon est la seule alimentation de l'aquifère profond. Une analyse des distributions spatiales de l'abaissement du niveau piézométrique et des tassements du sol montre que la région soumise à l'abaissement maximal de piézométrie n'est pas nécessairement celle des tassements maximaux du sol liés à la présence de la couche de limon non consolidé. Une simple révision des débits de pompage basée sur la distribution spatiale de la couche de limon épaisse peut réduire significativement les tassements du sol. Resumen. La ciudad de Suzhou, situada en el tramo inferior del Río Yangtze, al sudeste de la provincia de Jiangsu, es una de las pocas ciudades chinas que padece problemas serios de subsidencia. Esto ha motivado la realización de un proyecto de investigación en la zona. Estudios geológicos e hidrogeológicos apuntan a un modelo de acuífero multicapa, con tres niveles distintos de lodos blandos de orígenes marino y lacustre. Examinando los registros históricos de extracciones de agua subterránea, así como de nivel piezométrico y de subsidencia, se observa que ésta se halla asociada al bombeo cada vez mayor del acuífero confinado profundo. La hipótesis es que las capas de lodos blandos se van consolidando, si bien la que más contribuye a ello es la tercera, potente y próxima al acuífero más explotado. Se ha realizado un modelo numérico tridimensional en diferencias finitas que representa el sistema acuífero multicapa, con lo que se puede estudiar el efecto de la extracción de agua subterránea en la subsidencia. Calibrando el modelo con niveles piezométricos medidos y con datos de subsidencia, se ha podido estimar los parámetros del acuífero. Los resultados del modelo ajustan de forma razonable con los datos medidos, por lo que el modelo numérico es capaz de reproducir los procesos dinámicos de flujo de aguas subterráneas y consolidación del terreno. La conductividad hidráulica de la tercera capa de lodo cerca del centro de asentamiento se ha reducido en más del 30% durante los últimos 14 años. El deterioro gradual de la conductividad hidráulica del lodo puede tener efectos adversos notables en la sustentabilidad de los recursos de agua subterránea del acuífero confinado profundo, ya que se recarga exclusivamente de acuíferos más someros a través de la capa de lodo. El análisis de la distribución espacial de descenso del nivel piezométrico y de subsidencia muestra que el área de extracción máxima no coincide necesariamente con la de máxima subsidencia, debido a la existencia de la capa de lodos blandos. Una mera redistribución de los caudales de bombeo en función de las propiedades espaciales de la gruesa capa de lodos podría reducir drásticamente los problemas de subsidencia.

  3. Subgingival microbiome in patients with healthy and ailing dental implants

    PubMed Central

    Zheng, Hui; Xu, Lixin; Wang, Zicheng; Li, Lianshuo; Zhang, Jieni; Zhang, Qian; Chen, Ting; Lin, Jiuxiang; Chen, Feng

    2015-01-01

    Dental implants are commonly used to replace missing teeth. However, the dysbiotic polymicrobial communities of peri-implant sites are responsible for peri-implant diseases, such as peri-implant mucositis and peri-implantitis. In this study, we analyzed the microbial characteristics of oral plaque from peri-implant pockets or sulci of healthy implants (n = 10), peri-implant mucositis (n = 8) and peri-implantitis (n = 6) sites using pyrosequencing of the 16S rRNA gene. An increase in microbial diversity was observed in subgingival sites of ailing implants, compared with healthy implants. Microbial co-occurrence analysis revealed that periodontal pathogens, such as Porphyromonas gingivalis, Tannerella forsythia, and Prevotella intermedia, were clustered into modules in the peri-implant mucositis network. Putative pathogens associated with peri-implantitis were present at a moderate relative abundance in peri-implant mucositis, suggesting that peri-implant mucositis an important early transitional phase during the development of peri-implantitis. Furthermore, the relative abundance of Eubacterium was increased at peri-implantitis locations, and co-occurrence analysis revealed that Eubacterium minutum was correlated with Prevotella intermedia in peri-implantitis sites, which suggests the association of Eubacterium with peri-implantitis. This study indicates that periodontal pathogens may play important roles in the shifting of healthy implant status to peri-implant disease. PMID:26077225

  4. Using environmental isotopes in the study of the recharge-discharge mechanisms of the Yarmouk catchment area in Jordan

    NASA Astrophysics Data System (ADS)

    Salameh, Elias

    The recharge sources, the flow mechanisms and discharge areas of the different groundwater bodies underlying the Yarmouk River catchment area in Jordan, have, until now, not been adequately explained, although a wide range of hydrological, hydrogeological, and hydrochemical studies have been done. Along the Jordanian part of the catchment area of the Yarmouk River, groundwater issues from different aquifers with a variety of chemistries and types within the same aquifer and in between the different aquifers. Conventional recharge/discharge mechanisms, water balances and chemical analyses did not adequately explain the chemical variations and the different water types found in the area. Applying environmental isotopic tools combined with their altitude effects due to topographic variations (250-1,300 m a.s.l. within a distance of 20 km), and taking into consideration re-evaporation effects on the isotopic depletion and enrichment of rainwater, has greatly helped in understanding the recharge discharge mechanisms of the different aquifers. Precipitation along the highlands of an average of 600 mm/year is found to be depleted in its isotopic content of δO18 = -7.0 to -7.26 and δD = -32.2 to -33.28, whereas that of the Jordan Valley of 350 mm/year is highly enriched in isotopes with δO18 = -4.06 and δD = -14.5. The groundwater recharged along the highlands is depleted in isotopes (δO18 = -6, δD = -30), groundwater at the intermediate elevations is enriched (δO18 = -5, δD = -23) and that of the Jordan Valley aquifers containing meteoric water is highly enriched (δO18 -3.8, δD = -18). The deep aquifers in the Jordan Valley foothills are depleted in isotopes (δO18 -18 = -6, δD = -30) and resemble those of the highland aquifers. Only through using isotopes as a tool, were the sources of the different groundwater bodies and recharge and discharge mechanisms unambiguously explained. It was found that recharge takes place all over the study area and produces groundwater, which, from the highlands towards the Jordan Valley, shows increasing enrichment in isotopes. The highlands aquifer, with its groundwater depleted in isotopes, becomes confined towards the Jordan Valley; and, due to its confining pressure, leaks water upwards into the overlying aquifers causing their water to become less enriched in isotopes. Water depleted in its isotopic composition also seeps upward to the ground surface at the mountain foothills through faults and fissures. Les zones de recharge, les mécanismes d'écoulement et les zones de décharges des différentes masses d'eau souterraine sous le bassin versant de la rivière Yarmouk en Jordanie, étaient expliquées de manière ambiguë par les seuls outils isotopiques. Le long de la parti Jordanienne du bassin versant de la rivière Yarmouk l'eau souterraine provient de différents aquifères et se distinguent par leur type et leur composition chimique, selon que l'eau provient du même ou des différents aquifères. Les mécanismes conventionnels de recharge et de décharge, bilan hydrologique ne donnaient pas d'explications satisfaisantes concernant les variations chimiques et les différents types d'eau. En appliquant les isotopes environnementaux combinés aux effets de l'altitude sur les variations des teneurs isotopiques (l'altitude varie de 250 à 1,300 m sur une distance de 20 km.) et en prenant en considération les effets de ré-évaporation sur l'appauvrissement et l'enrichissement isotopique des eaux pluviales ont fortement contribués à une meilleure compréhension des mécanismes de recharge des différents aquifères. Les précipitations annuelles sont comprises entre 600 mm dans les zones en altitude et 350 mm dans la vallée de la Jordanie. Les écoulements de l'eau souterraine sont dirigés des zones en altitude vers la vallée de la Jordanie. Les eaux souterraines des zones en altitude sont isotopiquement appauvries (δO18 = -6, δD = -30), les eaux souterraines des zones de moyenne altitude sont enrichies (δO18 = -5, δD = -23) et les eaux de la vallée très enrichies (δO18 -3.8, δD = -18). Les aquifers profonds dans la vallée de la Jordanie sont appauvris (δO18 -18 = -6, δD = -30) et se confondent avec les eaux des zones situées en altitude. En appliquant uniquement les isotopes environnementaux comme des outils de compréhension des phénomènes hydrogéologiques, la source des différentes masses d'eau souterraines, les mécanismes de la recharge et de la décharge pourraient être expliqués de manière ambiguë. Las fuentes de recarga, los mecanismos de flujo y las áreas de descarga de los diferentes cuerpos de agua subterránea que subyacen el área de la cuenca del Río Yarmouk en Jordania, se han explicado de manera no ambigua únicamente mediante la aplicación de los isótopos como herramienta. A lo largo de la parte Jordana del área de la cuenca del Río Yarmouk el agua subterránea emerge de diferentes acuíferos con una variedad de tipos y composiciones, ya sea que provengan del mismo acuífero o de diferentes acuíferos. Los mecanismos convencionales de recarga/descarga, balances hídricos y variaciones químicas no han podido explicar las variaciones químicas y los diferentes tipos de aguas. La aplicación de herramientas de isótopos ambientales combinadas con los efectos de altitud derivados de variaciones topográficas (250 hasta 1,300 m s.n.m. en una distancia de 20 km) y tomando en consideración los efectos de re-evaporación en el empobrecimiento de isótopos y enriquecimiento del agua de lluvia han ayudado fuertemente en el entendimiento de los mecanismos de recarga/descarga de los diferentes acuíferos. La precipitación en el área varía de 600 mm/año, a lo largo de las tierras altas, a 350 mm/año en el área del Valle Jordán. El flujo de agua subterránea ocurre de las tierras altas hacia el Valle Jordán. El agua subterránea de las tierras altas está empobrecida en isótopos (δO18 = -6, δD = -30), el agua subterránea de elevaciones intermedias está enriquecida (δO18 = -5, δD = -23), y el agua de los acuíferos del Valle Jordan contiene agua meteórica que se encuentra altamente enriquecida (δO18 = -3.8, δD = -18). Los acuíferos profundos que se localizan al pie de las tierras altas del Valle Jordán están empobrecidos en isótopos (δO18 = -6, δD = -30) y son similares a los acuíferos de las tierras altas. Solo al aplicar los isótopos ambientales como herramienta pudo explicarse de manera inequívoca las fuentes de los diferentes cuerpos de agua subterránea y los mecanismos de recarga y descarga.

  5. El Efecto de la Educacion Bilingue Bicultural en los Autoconceptos y las Actitudes de Ninos Hispanicos

    ERIC Educational Resources Information Center

    Belendez, Pilar; Melendez, Sarah E.

    1977-01-01

    Written in Spanish, the article reports a study which compared the self concepts and attitudes toward their culture, the American culture, and school of Hispanic students in a maintenance and a transitional bilingual-bicultural program and in a monolingual school. (NQ)

  6. Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results.

    PubMed

    Sabir, Mohammad; Alam, Mohammad Nazish

    2015-06-01

    The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved.

  7. A new system of implant abutment connection: how to improve a two piece implant system sealing.

    PubMed

    Grecchi, F; DI Girolamo, M; Cura, F; Candotto, V; Carinci, F

    2017-01-01

    Implant dentistry has become one of the most successful dentistry techniques for replacing missing teeth. The success rate of implant dentistry is above 80%. However, peri-implantitis is a later complication of implant dentistry that if untreated, can lead to implant loss. One of the hypotized causes of peri-implantis is the bacterial leakage at the level of implant-abutment connection. Bacterial leakage is favored to the presence of a micro gap at the implant-abutment interface, allowing microorganisms to penetrate and colonize the inner part of the implant leading to biofilm accumulation and consequently to peri-implantitis development. To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Implants were immerged in a bacterial culture for twenty-four hours and then bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 9%. The reported results are better to those of previous studies carried out on different implant systems. Until now, none implant-abutment system has been proven to seal the gap between implant and abutment.

  8. Incidence of Peri-implant Diseases on Implants With and Without Laser-Microgrooved Collar: A 5-Year Retrospective Study Carried Out in Private Practice Patients.

    PubMed

    Guarnieri, Renzo; Grande, Maurizio; Zuffetti, Francesco; Testori, Tiziano

    To retrospectively evaluate the incidence of peri-implant mucositis and peri-implantitis around dental implants with the same body design and surface but different collar surface (laser-microgrooved vs not laser-microgrooved) after 5 years of loading in private practice patients. The study was carried out on patients at a private dental clinic enrolled in a periodontal maintenance program, who received at least one implant with a laser-microgrooved collar surface and one implant without a laser-microgrooved collar surface. Clinical variables such as plaque, pocket depth, bleeding on probing, suppuration, and radiographic marginal bone loss at > 5 years around implants were investigated. The correlation between the prevalence of peri-implant mucositis/peri-implantitis and biotype, keratinized tissue width, prosthetic connection type, and prosthetic design type was also analyzed. A total of 166 implants in 74 patients were investigated. At the end of the 5-year follow-up period, 38 implants presented peri-implant mucositis, accounting for 22.8% of the total, affecting a total of 24 patients (32.4%), while 13 implants (7.8%) in 10 patients (13.5%) were diagnosed with peri-implantitis. Sixteen of 82 laser-microgrooved implants (19.5%) and 24 of 84 implants (28.5%) without a laser-microgrooved collar presented peri-implant mucositis, while 3 of 82 (3.6%) of laser-microgrooved implants and 10 of 84 (11.9%) implants without a laser-microgrooved collar demonstrated peri-implantitis. Differences in implant-based incidence of peri-implant diseases between implants with and without a laser-microgrooved collar were statistically significant (P < .05). In private practice patients enrolled in a professional, controlled oral hygiene regimen, implants with a laser-microgrooved collar, compared with implants without a laser-microgrooved collar, presented a statistically significantly lower incidence of peri-implant diseases.

  9. Influence of Palatal Coverage and Implant Distribution on Implant Strain in Maxillary Implant Overdentures.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Mizuno, Yoko; Fujinami, Yozo; Maeda, Yoshinobu

    2016-01-01

    Maxillary implant overdentures are often used in clinical practice. However, there is no agreement or established guidelines regarding prosthetic design or optimal implant placement configuration. The purpose of this study was to examine the influence of palatal coverage and implant number and distribution in relation to impact strain under maxillary implant overdentures. A maxillary edentulous model with implants and experimental overdentures with and without palatal coverage was fabricated. Four strain gauges were attached to each implant, and they were positioned in the anterior, premolar, and molar areas. A vertical occlusal load of 98 N was applied through a mandibular complete denture, and the implant strains were compared using one-way analysis of variance (P = .05). The palatolabial strain was much higher on anterior implants than on other implants in both denture types. Although there was no significant difference between the strain under dentures with and without palatal coverage, palateless dentures tended to result in higher implant strain than dentures with palatal coverage. Dentures supported by only two implants registered higher strain than those supported by four or six implants. Implants under palateless dentures registered higher strain than those under dentures with palatal coverage. Anterior implants exhibited higher palatolabial strain than other implants regardless of palatal coverage and implant configuration; it is therefore recommended that maxillary implant overdentures should be supported by six implants with support extending to the distal end of the arch.

  10. Effect of widespread agricultural chemical use on butterfly diversity across Turkish provinces.

    PubMed

    Pekin, Burak K

    2013-12-01

    Although agricultural intensification is thought to pose a significant threat to species, little is known about its role in driving biodiversity loss at regional scales. I assessed the effects of a major component of agricultural intensification, agricultural chemical use, and land-cover and climatic variables on butterfly diversity across 81 provinces in Turkey, where agriculture is practiced extensively but with varying degrees of intensity. I determined butterfly species presence in each province from data on known butterfly distributions and calculated agricultural chemical use as the proportion of agricultural households that use chemical fertilizers and pesticides. I used constrained correspondence analyses and regression-based multimodel inference to determine the effect of environmental variables on species composition and richness, respectively. The variation in butterfly species composition across the provinces was largely explained (78%) by the combination of agricultural chemical use, particularly pesticides, and climatic and land-cover variables. Although overall butterfly richness was primarily explained by climatic and land-cover variables, such as the area of natural vegetation cover, threatened butterfly richness and the relative number of threatened butterfly species decreased substantially as the proportion of agricultural households using pesticides increased. These findings suggest that widespread use of agricultural chemicals, or other components of agricultural intensification that may be collinear with pesticide use, pose an imminent threat to the biodiversity of Turkey. Accordingly, policies that mitigate agricultural intensification and promote low-input farming practices are crucial for protecting threatened species from extinction in rapidly industrializing nations such as Turkey. Efectos del Uso Extensivo de Agroquímicos sobre la Diversidad de Mariposas en Provincias Turcas. © 2013 Society for Conservation Biology.

  11. [In Process Citation].

    PubMed

    Álvarez, Cristian; Ramírez-Campillo, Rodrigo; Vallejos-Rojas, Andrea; Jaramillo-Gallardo, Javiera; Salas Bravo, Carlos; Cano-Montoya, Johnattan; Celis-Morales, Carlos

    2016-03-25

     Introducción: obesidad e inactividad física son importantes factores de riesgo para el desarrollo de hipertensión en adultos. No obstante, hay poca evidencia sobre el efecto de estos factores de riesgo en el desarrollo de hipertensión en población infantil. Objetivo: investigar la asociación del estado nutricional, niveles de actividad física y etnicidad con niveles de hipertensión en escolares entre 6 y 13 años de edad. Métodos: un total de 418 escolares de ascendencia étnica europea (n = 311) y mapuche (n = 107) fueron participantes de este estudio transversal. Se midió el peso, talla, índice de masa corporal (IMC) y presión arterial, utilizando protocolos estandarizados. Resultados: no se encontraron diferencias significativas en IMC, estado nutricional y presión arterial entre niños con ascendencia europea y mapuche. No obstante, la prevalencia de prehipertensión (21,3% vs. 11,1%) e hipertensión (28,9% vs. 18,6%) fue significativamente mayor en escolares mapuches en comparación con europeos, respectivamente. Escolares con ascendencia mapuche tienen un mayor riesgo de desarrollar prehipertensión o hipertensión que escolares con ascendencia europea (OR: 1,92 [1,19 a 3,06], p < 0,01). La prevalencia de hipertensión aumenta significativamente en ambos grupos étnicos con el incremento de IMC y bajos niveles de actividad física. Conclusiones: el riesgo de desarrollar prehipertensión o hipertensión es mayor en población infantil ascendiente de mapuches que ascendiente de europeos y este riesgo se ve acentuado con el incremento de obesidad y bajos niveles de actividad física.

  12. Dental Implant Macro-Design Features Can Impact the Dynamics of Osseointegration.

    PubMed

    Vivan Cardoso, Marcio; Vandamme, Katleen; Chaudhari, Amol; De Rycker, Judith; Van Meerbeek, Bart; Naert, Ignace; Duyck, Joke

    2015-08-01

    The purpose of this study was to compare the clinical performance of two dental implant types possessing a different macro-design in the in vivo pig model. Titanium Aadva(TM) implants (GC, Tokyo, Japan) were compared with OsseoSpeed(TM) implants (Astra, Mölndal, Sweden), with the Aadva implant displaying significant larger inter-thread dimensions than the OsseoSpeed implant. Implants were installed in the parietal bone of 12 domestic pigs and left for healing for either 1 or 3 months. Implant osseointegration was evaluated by quantitative histology (bone volume relative to the tissue volume [BV/TV]; bone-to-implant contact [BIC]) for distinct implant regions (collar, body, total implant length) with specific implant thread features. The Wilcoxon-Mann-Whitney nonparametric test with α = 0.05 was performed. An inferior amount of bone enveloping the Aadva implant compared with the OsseoSpeed implant was observed, in particular at the implant body part with its considerable inter-thread gaps (p < .05). Concomitantly, the Aadva macro-design negatively affected the amount of bone in direct contact with the implant for this specific implant part (p < .05), and resulted in an overall impaired implant osseointegration at the initial healing stage (total implant length; 1-month healing; p < .05). Although the Aadva implant displayed a clinically acceptable level of osseointegration, the findings demonstrate that implant macro-design features can impact the dynamics of implant osseointegration. Consideration of specific implant macro-design features should be made relative to the biological and mechanical microenvironment. © 2013 Wiley Periodicals, Inc.

  13. Imaging of common breast implants and implant-related complications: A pictorial essay

    PubMed Central

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer. PMID:27413269

  14. Imaging of common breast implants and implant-related complications: A pictorial essay.

    PubMed

    Shah, Amisha T; Jankharia, Bijal B

    2016-01-01

    The number of women undergoing breast implant procedures is increasing exponentially. It is, therefore, imperative for a radiologist to be familiar with the normal and abnormal imaging appearances of common breast implants. Diagnostic imaging studies such as mammography, ultrasonography, and magnetic resonance imaging are used to evaluate implant integrity, detect abnormalities of the implant and its surrounding capsule, and detect breast conditions unrelated to implants. Magnetic resonance imaging of silicone breast implants, with its high sensitivity and specificity for detecting implant rupture, is the most reliable modality to asses implant integrity. Whichever imaging modality is used, the overall aim of imaging breast implants is to provide the pertinent information about implant integrity, detect implant failures, and to detect breast conditions unrelated to the implants, such as cancer.

  15. Infection rates of rifampin/gentamicin-coated Titan Coloplast penile implants. Comparison with Inhibizone-impregnated AMS penile implants.

    PubMed

    Dhabuwala, Chirpriya; Sheth, Sheila; Zamzow, Brent

    2011-01-01

    It is a common practice to soak Titan(®) Coloplast penile implants in antibiotic solution prior to implantation. Experience with Inhibizone impregnation suggests that rifampin coating significantly reduces infection rates of penile implant surgery. In this article we describe the results of coating Titan Coloplast penile implants with rifampin/gentamicin solution. To compare infection rates of Titan(®) Coloplast penile implants coated with vancomycin/gentamycin, rifampin/gentamicin, and Inhibizone-impregnated American Medical Systems (AMS) penile implants. Chart review was done for all Mentor/Coloplast and AMS implant surgeries performed at our center between the dates January 1, 2002 and February 8, 2010. Infection rates for Titan(®) Coloplast penile implants coated with vancomycin/gentamycin, rifampin/gentamicin, and Inhibizone-impregnated (AMS) penile implants were compared. Infection rates for penile implants coated with different antibiotics. Infection rates for Titan(®) Coloplast penile implants coated with vancomycin/gentamycin and Inhibizone-impregnated (AMS) penile implants was 4.4% and 1.3%, respectively (P = 0.05). None of the rifampin/gentamicin-coated Titan(®) Coloplast penile implants have developed infection. Rifampin is the common antibiotic both in rifampin/gentamicin-coated Coloplast implants and Inhibizone(®) . The infection rate in this combined rifampin/gentamicin-coated Titan Coloplast implants and Inhibizone-coated AMS implants group was 0.63% (P = 0.03). Both rifampin/gentamicin-coated Titan(®) Coloplast penile implants and Inhibizone-impregnated (AMS) penile implants appear to have lower infection rates compared with vancomycin/gentamycin-coated Titan(®) Coloplast penile implants The present study does not suggest superiority of rifampin/gentamicin-coated Titan(®) Coloplast penile implants or Inhibizone-impregnated (AMS) penile implants but we strongly suggest that all Titan(®) Coloplast penile implants should be coated with rifampin/gentamicin solution. © 2010 International Society for Sexual Medicine.

  16. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study.

    PubMed

    Aunmeungtong, W; Khongkhunthian, P; Rungsiyakull, P

    2016-01-01

    Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force.

  17. Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale.

    PubMed

    Kim, Yongsik; Oh, Tae-Ju; Misch, Carl E; Wang, Hom-Lay

    2005-02-01

    Due to lack of the periodontal ligament, osseointegrated implants, unlike natural teeth, react biomechanically in a different fashion to occlusal force. It is therefore believed that dental implants may be more prone to occlusal overloading, which is often regarded as one of the potential causes for peri-implant bone loss and failure of the implant/implant prosthesis. Overloading factors that may negatively influence on implant longevity include large cantilevers, parafunctions, improper occlusal designs, and premature contacts. Hence, it is important to control implant occlusion within physiologic limit and thus provide optimal implant load to ensure a long-term implant success. The purposes of this paper are to discuss the importance of implant occlusion for implant longevity and to provide clinical guidelines of optimal implant occlusion and possible solutions managing complications related to implant occlusion. It must be emphasized that currently there is no evidence-based, implant-specific concept of occlusion. Future studies in this area are needed to clarify the relationship between occlusion and implant success.

  18. Peri-implant bone formation and surface characteristics of rough surface zirconia implants manufactured by powder injection molding technique in rabbit tibiae.

    PubMed

    Park, Young-Seok; Chung, Shin-Hye; Shon, Won-Jun

    2013-05-01

    To evaluate osseointegration in rabbit tibiae and to investigate surface characteristics of novel zirconia implants made by powder injection molding (PIM) technique, using molds with and without roughened inner surfaces. A total of 20 rabbits received three types of external hex implants with identical geometry on the tibiae: machined titanium implants, PIM zirconia implants without mold etching, and PIM zirconia implants with mold etching. Surface characteristics of the three types of implant were evaluated. Removal torque tests and histomorphometric analyses were performed. The roughness of PIM zirconia implants was higher than that of machined titanium implants. The PIM zirconia implants exhibited significantly higher bone-implant contact and removal torque values than the machined titanium implants (P < 0.001). The PIM zirconia implants using roughened mold showed significantly higher removal torque values than PIM zirconia implants without using roughened mold (P < 0.001). It is concluded that the osseointegration of PIM zirconia implant is promising and PIM using roughened mold etching technique can produce substantially rough surfaces on zirconia implants. © 2012 John Wiley & Sons A/S.

  19. Short Implants Versus Standard Implants: Midterm Outcomes of a Clinical Study.

    PubMed

    Benlidayi, M Emre; Ucar, Yurdanur; Tatli, Ufuk; Ekren, Orhun; Evlice, Burcu; Kisa, Halil Ibrahim; Baksi, Uygar

    2018-02-01

    The aim of this study was to evaluate the midterm survival rate, marginal bone resorption (MBR), and stability of short implants and to compare the results with standard length implants. A total of 38 patients were included. In total, 147 implants (Nucleoss Implants, Izmir, Turkey) were placed (86 short implants and 61 standard implants). Cement-retained metal-ceramic prostheses were fabricated. MBR was evaluated on periapical radiographs taken at implant placement, at the time of crown insertion and annually thereafter. The stability of the implants was evaluated by resonance frequency analysis. The 3- and 5-year cumulative survival rates for standard implants was 98.4% and for short implants was 96.5% (P = 0.644). The MBR of the short implants was significantly lower than that of the standard implants after 1, 2, and 3 years of loading (P < 0.05). No significant differences were found between 2 groups after 6 and 12 months of loading in terms of implant stability (implant stability quotient values) (P > 0.05). Within the limits of this study, it is concluded that short implants achieved similar results as standard implants after 3 to 5 years of loading.

  20. Effect of implant position, angulation, and attachment height on peri-implant bone stress associated with mandibular two-implant overdentures: a finite element analysis.

    PubMed

    Hong, Hae Ryong; Pae, Ahran; Kim, Yooseok; Paek, Janghyun; Kim, Hyeong-Seob; Kwon, Kung-Rock

    2012-01-01

    The aim of this study was to analyze and compare the level and distribution of peri-implant bone stresses associated with mandibular two-implant overdentures with different implant positions. Mathematical models of mandibles and overdentures were designed using finite element analysis software. Two intraosseous implants and ball attachment systems were placed in the interforaminal region. The overdenture, which was supported by the two implants, was designed to withstand bilateral and unilateral vertical masticatory loads (total 100 N). In all, eight types of models, which differed according to assigned implant positions, height of attachments, and angulation, were tested: MI (model with implants positioned in the lateral incisor sites), MC (implants in canine sites), MP (implants in premolar sites), MI-Hi (greater height of attachments), MC-M (canine implants placed with mesial inclination), MC-D (canine implants placed with distal inclination), MC-B (canine implants placed with buccal inclination), and MC-L (canine implants placed with lingual inclination). Peri-implant bone stress levels associated with overdentures retained by lateral incisor implants resulted in the lowest stress levels and the highest efficiency in distributing peri-implant stress. MI-Hi showed increased stress levels and decreased efficiency in stress distribution. As the implants were inclined, stress levels increased and the efficiency of stress distribution decreased. Among the inclined models, MC-B showed the lowest stress level and best efficiency in stress distribution. The lowest stress and the best stability of implants in mandibular two-implant overdentures were obtained when implants were inserted in lateral incisor areas with shorter attachments and were placed parallel to the long axes of the teeth.

  1. Survival of Implants in Immediate Extraction Sockets of Anterior Teeth: Early Clinical Results

    PubMed Central

    Sabir, Mohammad

    2015-01-01

    Background The aims and objectives of this study were placement of implants in freshly extracted sockets of anterior teeth and to evaluate the implant stability, peri-implant radiolucency and gingival inflammation around implant over a short period of 30 months. Materials and Methods A total of 12 patients (8 male and 4 female), ranging in the age from 20 to 50 years, from March 2007 to June 2007, were evaluated for immediate implant placement into 22 fresh extraction sockets. Only maxillary and mandibular anterior teeth/roots (central incisors, lateral incisors and canines) were considered for replacement with implants. One piece implant with integrated abutment and integrated surface, non-submerged, threaded and tapered at apical 5 mm, sand-blasted and acid etched surfaced implants (HI-TEC TRX-OP Implants of Life Care Company) were used. Results The mobility was not present in any of the implants at all the follow up visits. There were 2 implants at 6 month, 1 implant at 12 month, 1 implant at 18 month visits, showing peri-implant radiolucency at some sites at bone to implant contact site. Severe gingival inflammation was not observed in any of the implant site. At every follow-up visit, every implant met the criteria of success and none was found to be failed over a 30 months duration i.e. 100% success rate was achieved by implants in immediate extraction socket. Conclusion The success rate of implant survival in this study was found 100%. These implants have fulfilled all the criteria of implant success and based on the defined criteria, the success rate of implants placed in immediate extraction sockets of anterior teeth compared favorably with the conventional implants. The early results of the present study showed that high survival rates with the implants in immediate extraction sockets can be achieved. PMID:26266220

  2. [Effect of the number and inclination of implant on stress distribution for mandibular full-arch fixed prosthesis].

    PubMed

    Zheng, Xiaoying; Li, Xiaomei; Tang, Zhen; Gong, Lulu; Wang, Dalin

    2014-06-01

    To study the effect of implant number and inclination on stress distribution in implant and its surrounding bone with three-dimensional finite element analysis. A special denture was made for an edentulous mandible cast to collect three-dimensional finite element data. Three three-dimensional finite element models were established as follows. Model 1: 6 paralleled implants; model 2: 4 paralleled implants; model 3: 4 implants, the two anterior implants were parallel, the two distal implants were tilted 30° distally. Among the three models, the maximum stress values found in anterior implants, posterior implants, and peri-implant bone were modle 3

  3. Why are mini-implants lost: the value of the implantation technique!

    PubMed

    Romano, Fabio Lourenço; Consolaro, Alberto

    2015-01-01

    The use of mini-implants have made a major contribution to orthodontic treatment. Demand has aroused scientific curiosity about implant placement procedures and techniques. However, the reasons for instability have not yet been made totally clear. The aim of this article is to establish a relationship between implant placement technique and mini-implant success rates by means of examining the following hypotheses: 1) Sites of poor alveolar bone and little space between roots lead to inadequate implant placement; 2) Different sites require mini-implants of different sizes! Implant size should respect alveolar bone diameter; 3) Properly determining mini-implant placement site provides ease for implant placement and contributes to stability; 4) The more precise the lancing procedures, the better the implant placement technique; 5) Self-drilling does not mean higher pressures; 6) Knowing where implant placement should end decreases the risk of complications and mini-implant loss.

  4. Comparison of peri-implant bone formation around injection-molded and machined surface zirconia implants in rabbit tibiae

    PubMed Central

    Kim, Hong-Kyun; Woo, Kyung mi; Shon, Won-Jun; Ahn, Jin-Soo; Cha, Seunghee; Park, Young-Seok

    2017-01-01

    The aim of this study was to compare osseointegration and surface characteristics of zirconia implants made by the powder injection molding (PIM) technique and made by the conventional milling procedure in rabbit tibiae. Surface characteristics of 2 types of implant were evaluated. Sixteeen rabbits received 2 types of external hex implants with similar geometry, machined zirconia implants and PIM zirconia implants, in the tibiae. Removal torque tests and histomorphometric analyses were performed. The roughness of PIM zirconia implants was higher than that of machined zirconia implants. The PIM zirconia implants exhibited significantly higher bone-implant contact and removal torque values than the machined zirconia implants (P < 0.001). The osseointegration of the PIM zirconia implant is promising, and PIM, using the roughened mold etching technique, can produce substantially rough surfaces on zirconia implants. PMID:26235717

  5. Evaluation of possible prognostic factors for the success, survival, and failure of dental implants.

    PubMed

    Geckili, Onur; Bilhan, Hakan; Geckili, Esma; Cilingir, Altug; Mumcu, Emre; Bural, Canan

    2014-02-01

    To analyze the prognostic factors that are associated with the success, survival, and failure rates of dental implants. Data including implant sizes, insertion time, implant location, and prosthetic treatment of 1656 implants have been collected, and the association of these factors with success, survival, and failure of implants was analyzed. The success rate was lower for short and maxillary implants. The failure rate of maxillary implants exceeded that of mandibular implants, and the failure rate of implants that were placed in the maxillary anterior region was significantly higher than other regions. The failure rates of implants that were placed 5 years ago or more were higher than those that were placed later. Anterior maxilla is more critical for implant loss than other sites. Implants in the anterior mandible show better success compared with other locations, and longer implants show better success rates. The learning curve of the clinician influences survival and success rates of dental implants.

  6. [Comparative evaluation of two kinds of micro-implant system with different size].

    PubMed

    Wang, Zhen-Dong; Li, Qing-Yi; Wang, Lin; Gu, Yong-Jia

    2009-04-01

    To offer some reference for micro-implant's development and population by analyzing clinical application of two kinds of micro-implant systems. 38 patients treated with MIA (micro-implant anchorage) and 28 patients treated with SDIA (self-driven titanium implant for orthodontic anchorage) were included. Analyzing the rate of lost implants, the gum's reactivity and the efficiency of moving teeth summarized the excellences and shortcomings of two systems. 1) Six of MIA implants fell off after being inserted. Seven of SDIA implants lost when they had been implanted for a month. But they were stable after being inserted again. 2) The gum around 12 SDIA implants got inflammation symptom, but the gum around MIA implants was normal. 3) Both MIA implants and SDIA implants could move teeth effectively and persistently when they were stable. When we apply micro-implant in clinic, we should prevent it from closing roots of teeth and choose the small tip micro-implant. The embedded position should be in area of attachment gum. At the same time, the areas around the tip of micro-implant should be keeping clean.

  7. Comparison of surface modified zirconia implants with commercially available zirconium and titanium implants: a histological study in pigs.

    PubMed

    Gredes, Tomasz; Kubasiewicz-Ross, Pawel; Gedrange, Tomasz; Dominiak, Marzena; Kunert-Keil, Christiane

    2014-08-01

    New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.

  8. Acid Etching and Plasma Sterilization Fail to Improve Osseointegration of Grit Blasted Titanium Implants

    PubMed Central

    Saksø, Mikkel; Jakobsen, Stig S; Saksø, Henrik; Baas, Jørgen; Jakobsen, Thomas; Søballe, Kjeld

    2012-01-01

    Interaction between implant surface and surrounding bone influences implant fixation. We attempted to improve the bone-implant interaction by 1) adding surface micro scale topography by acid etching, and 2) removing surface-adherent pro-inflammatory agents by plasma cleaning. Implant fixation was evaluated by implant osseointegration and biomechanical fixation. The study consisted of two paired animal sub-studies where 10 skeletally mature Labrador dogs were used. Grit blasted titanium alloy implants were inserted press fit in each proximal tibia. In the first study grit blasted implants were compared with acid etched grit blasted implants. In the second study grit blasted implants were compared with acid etched grit blasted implants that were further treated with plasma sterilization. Implant performance was evaluated by histomorphometrical investigation (tissue-to-implant contact, peri-implant tissue density) and mechanical push-out testing after four weeks observation time. Neither acid etching nor plasma sterilization of the grit blasted implants enhanced osseointegration or mechanical fixation in this press-fit canine implant model in a statistically significant manner. PMID:22962567

  9. A Retrospective Analysis of Ruptured Breast Implants

    PubMed Central

    Baek, Woo Yeol; Lew, Dae Hyun

    2014-01-01

    Background Rupture is an important complication of breast implants. Before cohesive gel silicone implants, rupture rates of both saline and silicone breast implants were over 10%. Through an analysis of ruptured implants, we can determine the various factors related to ruptured implants. Methods We performed a retrospective review of 72 implants that were removed for implant rupture between 2005 and 2014 at a single institution. The following data were collected: type of implants (saline or silicone), duration of implantation, type of implant shell, degree of capsular contracture, associated symptoms, cause of rupture, diagnostic tools, and management. Results Forty-five Saline implants and 27 silicone implants were used. Rupture was diagnosed at a mean of 5.6 and 12 years after insertion of saline and silicone implants, respectively. There was no association between shell type and risk of rupture. Spontaneous was the most common reason for the rupture. Rupture management was implant change (39 case), microfat graft (2 case), removal only (14 case), and follow-up loss (17 case). Conclusions Saline implants have a shorter average duration of rupture, but diagnosis is easier and safer, leading to fewer complications. Previous-generation silicone implants required frequent follow-up observation, and it is recommended that they be changed to a cohesive gel implant before hidden rupture occurs. PMID:25396188

  10. Effect of Attachment Type on Implant Strain in Maxillary Implant Overdentures: Comparison of Ball, Locator, and Magnet Attachments. Part 1. Overdenture with Palate.

    PubMed

    Takahashi, Toshihito; Gonda, Tomoya; Maeda, Yoshinobu

    Implant overdentures with attachments have been used in clinical practice and the effect of attachments on implant strain has been frequently reported. However, most studies have focused on mandibular overdentures; there are few reports on maxillary overdentures. The purpose of this study was to examine the influence of attachment type on implant strain in maxillary overdentures under various implant configurations. A maxillary edentulous model with implants and experimental overdentures were fabricated. Four strain gauges were attached to each implant, positioned in anterior, premolar, and molar areas. Three types of unsplinted attachments-ball, locator, and magnet-were set on the implants under various implant configurations. A vertical occlusal load of 98 N was applied through the mandibular complete denture, and implant strain was compared using the Kruskal-Wallis test. Ball attachments caused the greatest amount of strain, while magnet attachments caused the least amount under all conditions. For all attachments, two anterior implants caused significantly more strain than four implants (P < .05). No significant difference was observed between subtypes in four-implant configurations except when using locator attachments. When using unsplinted attachments for maxillary implant overdentures, magnet attachments are recommended to reduce implant stress. Using only two implants, especially two anterior implants, is not recommended regardless of attachment type.

  11. Effect of implant design and bioactive glass coating on biomechanical properties of fiber-reinforced composite implants.

    PubMed

    Ballo, Ahmed M; Akca, Eralp; Ozen, Tuncer; Moritz, Niko; Lassila, Lippo; Vallittu, Pekka; Närhi, Timo

    2014-08-01

    This study aimed to evaluate the influence of implant design and bioactive glass (BAG) coating on the response of bone to fiber-reinforced composite (FRC) implants. Three different FRC implant types were manufactured for the study: non-threaded implants with a BAG coating; threaded implants with a BAG coating; and threaded implants with a grit-blasted surface. Thirty-six implants (six implants for each group per time point) were installed in the tibiae of six pigs. After an implantation period of 4 and 12 wk, the implants were retrieved and prepared for micro-computed tomography (micro-CT), push-out testing, and scanning electron microscopy analysis. Micro-CT demonstrated that the screw-threads and implant structure remained undamaged during the installation. The threaded FRC/BAG implants had the highest bone volume after 12 wk of implantation. The push-out strengths of the threaded FRC/BAG implants after 4 and 12 wk (463°N and 676°N, respectively) were significantly higher than those of the threaded FRC implants (416°N and 549°N, respectively) and the nonthreaded FRC/BAG implants (219°N and 430°N, respectively). Statistically significant correlation was found between bone volume and push-out strength values. This study showed that osseointegrated FRC implants can withstand the static loading up to failure without fracture, and that the addition of BAG significantly improves the push-out strength of FRC implants. © 2014 Eur J Oral Sci.

  12. Finite element analysis of different loading conditions for implant-supported overdentures supported by conventional or mini implants.

    PubMed

    Solberg, K; Heinemann, F; Pellikaan, P; Keilig, L; Stark, H; Bourauel, C; Hasan, I

    2017-05-01

    The effect of implants' number on overdenture stability and stress distribution in edentulous mandible, implants and overdenture was numerically investigated for implant-supported overdentures. Three models were constructed. Overdentures were connected to implants by means of ball head abutments and rubber ring. In model 1, the overdenture was retained by two conventional implants; in model 2, by four conventional implants; and in model 3, by five mini implants. The overdenture was subjected to a symmetrical load at an angle of 20 degrees to the overdenture at the canine regions and vertically at the first molars. Four different loading conditions with two total forces (120, 300 N) were considered for the numerical analysis. The overdenture displacement was about 2.2 times higher when five mini implants were used rather than four conventional implants. The lowest stress in bone bed was observed with four conventional implants. Stresses in bone were reduced by 61% in model 2 and by 6% in model 3 in comparison to model 1. The highest stress was observed with five mini implants. Stresses in implants were reduced by 76% in model 2 and 89% increased in model 3 compared to model 1. The highest implant displacement was observed with five mini implants. Implant displacements were reduced by 29% in model 2, and increased by 273% in model 3 compared to model 1. Conventional implants proved better stability for overdenture than mini implants. Regardless the type and number of implants, the stress within the bone and implants are below the critical limits.

  13. "Not all breast implants are equal: a 13-year review of implant longevity and reasons for explantation".

    PubMed

    Van Slyke, Aaron C; Carr, Michael; Carr, Nicholas J

    2018-06-04

    Augmentation mammoplasty is the most common aesthetic procedure. Textured implants control implant position and have improved capsular contracture rates; however, the impact of texturing on longevity and clinical findings at explantation is unclear. All cases of explantation between January 2005 - April 2017 from an aesthetic practice were reviewed retrospectively. Patient demographics, implant characteristics, time-to-explantation, and clinical presentation and intraoperative findings at explantation were analyzed. 539 breast implants were explanted during the study period: 249 saline, 147 smooth gel, 123 Biocell, and 20 other nonaggressively textured breast implants. Average time from placement to explantation was 7.5 years, 5.6 years, 4.9 years, and 4.0 years for saline, other textured, smooth gel, and Biocell implants, respectively (p-value = 3.25e-08). The percentage of implants removed associated with implant performance failure was 50.3%, 57.5%, 75.0%, and 85.4% for smooth gel, saline, other textured, and Biocell implants, respectively (p-value = 7.25e-09). 21.1% of Biocell implants versus 1.5% of all other implants presented with pain (p-value = 2.71e-15). 45 Biocell implants had double capsules; this phenomenon was not observed with any other implant type (p-value = 5.85e-37). Seven Biocell implants had late seromas, compared to three late seromas with any other implant type (p-value = 0.0013). Here, we provide evidence that Biocell implants have the shortest time-to-explantation and the highest proportion of implants associated with implant performance failure. This information should complement the informed consent process when selecting an appropriate implant.

  14. Breast Implant-Associated Anaplastic Large Cell Lymphoma in Australia and New Zealand: High-Surface-Area Textured Implants Are Associated with Increased Risk.

    PubMed

    Loch-Wilkinson, Anna; Beath, Kenneth J; Knight, Robert John William; Wessels, William Louis Fick; Magnusson, Mark; Papadopoulos, Tim; Connell, Tony; Lofts, Julian; Locke, Michelle; Hopper, Ingrid; Cooter, Rodney; Vickery, Karen; Joshi, Preeti Avinash; Prince, H Miles; Deva, Anand K

    2017-10-01

    The association between breast implants and breast implant-associated anaplastic large cell lymphoma (ALCL) has been confirmed. Implant-related risk has been difficult to estimate to date due to incomplete datasets. All cases in Australia and New Zealand were identified and analyzed. Textured implants reported in this group were subjected to surface area analysis. Sales data from three leading breast implant manufacturers (i.e., Mentor, Allergan, and Silimed) dating back to 1999 were secured to estimate implant-specific risk. Fifty-five cases of breast implant-associated ALCL were diagnosed in Australia and New Zealand between 2007 and 2016. The mean age of patients was 47.1 years and the mean time of implant exposure was 7.46 years. There were four deaths in the series related to mass and/or metastatic presentation. All patients were exposed to textured implants. Surface area analysis confirmed that higher surface area was associated with 64 of the 75 implants used (85.3 percent). Biocell salt loss textured (Allergan, Inamed, and McGhan) implants accounted for 58.7 percent of the implants used in this series. Comparative analysis showed the risk of developing breast implant-associated ALCL to be 14.11 times higher with Biocell textured implants and 10.84 higher with polyurethane (Silimed) textured implants compared with Siltex textured implants. This study has calculated implant-specific risk of breast implant-associated ALCL. Higher-surface-area textured implants have been shown to significantly increase the risk of breast implant-associated ALCL in Australia and New Zealand. The authors present a unifying hypothesis to explain these observations.

  15. Fortifying the Bone-Implant Interface Part 2: An In Vivo Evaluation of 3D-Printed and TPS-Coated Triangular Implants.

    PubMed

    MacBarb, Regina F; Lindsey, Derek P; Woods, Shane A; Lalor, Peggy A; Gundanna, Mukund I; Yerby, Scott A

    2017-01-01

    Minimally invasive surgical fusion of the sacroiliac (SI) joint using machined solid triangular titanium plasma spray (TPS) coated implants has demonstrated positive clinical outcomes in SI joint pain patients. Additive manufactured (AM), i.e. 3D-printed, fenestrated triangular titanium implants with porous surfaces and bioactive agents, such as nanocrystalline hydroxyapatite (HA) or autograft, may further optimize bony fixation and subsequent biomechanical stability. A bilateral ovine distal femoral defect model was used to evaluate the cancellous bone-implant interfaces of TPS-coated and AM implants. Four implant groups (n=6/group/time-point) were included: 1)TPS-coated, 2)AM, 3)AM+HA, and 4)AM+Autograft. The bone-implant interfaces of 6- and 12-week specimens were investigated via radiographic, biomechanical, and histomorphometric methods. Imaging showed peri-implant bone formation around all implants. Push-out testing demonstrated forces greater than 2500 N, with no significant differences among groups. While TPS implants failed primarily at the bone-implant interface, AM groups failed within bone ~2-3mm away from implant surfaces. All implants exhibited bone ongrowth, with no significant differences among groups. AM implants had significantly more bone ingrowth into their porous surfaces than TPS-coated implants ( p <0.0001). Of the three AM groups, AM+Auto implants had the greatest bone ingrowth into the porous surface and through their core ( p <0.002). Both TPS and AM implants exhibited substantial bone ongrowth and ingrowth, with additional bone through growth into the AM implants' core. Overall, AM implants experienced significantly more bone infiltration compared to TPS implants. While HA-coating did not further enhance results, the addition of autograft fostered greater osteointegration for AM implants. Additive manufactured implants with a porous surface provide a highly interconnected porous surface that has comparatively greater surface area for bony integration. Results suggest this may prove advantageous toward promoting enhanced biomechanical stability compared to TPS-coated implants for SI joint fusion procedures.

  16. Peri-implantitis.

    PubMed

    Schwarz, Frank; Derks, Jan; Monje, Alberto; Wang, Hom-Lay

    2018-06-01

    This narrative review provides an evidence-based overview on peri-implantitis for the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions. A literature review was conducted addressing the following topics: 1) definition of peri-implantitis; 2) conversion from peri-implant mucositis to peri-implantitis, 3) onset and pattern of disease progression, 4) characteristics of peri-implantitis, 5) risk factors/indicators for peri-implantitis, and 6) progressive crestal bone loss in the absence of soft tissue inflammation. 1)Peri-implantitis is a pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant connective tissue and progressive loss of supporting bone. 2)The histopathologic and clinical conditions leading to the conversion from peri-implant mucositis to peri-implantitis are not completely understood. 3)The onset of peri-implantitis may occur early during follow-up and the disease progresses in a non-linear and accelerating pattern. 4a)Peri-implantitis sites exhibit clinical signs of inflammation and increased probing depths compared to baseline measurements. 4b)At the histologic level, compared to periodontitis sites, peri-implantitis sites often have larger inflammatory lesions. 4c)Surgical entry at peri-implantitis sites often reveals a circumferential pattern of bone loss. 5a)There is strong evidence that there is an increased risk of developing peri-implantitis in patients who have a history of chronic periodontitis, poor plaque control skills, and no regular maintenance care after implant therapy. Data identifying "smoking" and "diabetes" as potential risk factors/indicators for peri-implantitis are inconclusive. 5b)There is some limited evidence linking peri-implantitis to other factors such as: post-restorative presence of submucosal cement, lack of peri-implant keratinized mucosa and positioning of implants that make it difficult to perform oral hygiene and maintenance. 6)Evidence suggests that progressive crestal bone loss around implants in the absence of clinical signs of soft tissue inflammation is a rare event. © 2018 American Academy of Periodontology and European Federation of Periodontology.

  17. Stress and strain distribution in three different mini dental implant designs using in implant retained overdenture: a finite element analysis study

    PubMed Central

    AUNMEUNGTONG, W.; KHONGKHUNTHIAN, P.; RUNGSIYAKULL, P.

    2016-01-01

    SUMMARY Finite Element Analysis (FEA) has been used for prediction of stress and strain between dental implant components and bone in the implant design process. Purpose Purpose of this study was to characterize and analyze stress and strain distribution occurring in bone and implants and to compare stress and strain of three different implant designs. Materials and methods Three different mini dental implant designs were included in this study: 1. a mini dental implant with an internal implant-abutment connection (MDIi); 2. a mini dental implant with an external implant-abutment connection (MDIe); 3. a single piece mini dental implant (MDIs). All implant designs were scanned using micro-CT scans. The imaging details of the implants were used to simulate models for FEA. An artificial bone volume of 9×9 mm in size was constructed and each implant was placed separately at the center of each bone model. All bone-implant models were simulatively loaded under an axial compressive force of 100 N and a 45-degree force of 100 N loading at the top of the implants using computer software to evaluate stress and strain distribution. Results There was no difference in stress or strain between the three implant designs. The stress and strain occurring in all three mini dental implant designs were mainly localized at the cortical bone around the bone-implant interface. Oblique 45° loading caused increased deformation, magnitude and distribution of stress and strain in all implant models. Conclusions Within the limits of this study, the average stress and strain in bone and implant models with MDIi were similar to those with MDIe and MDIs. The oblique 45° load played an important role in dramatically increased average stress and strain in all bone-implant models. Clinical implications Mini dental implants with external or internal connections have similar stress distribution to single piece mini dental implants. In clinical situations, the three types of mini dental implant should exhibit the same behavior to chewing force. PMID:28042449

  18. Biomechanical behavior of 2-implant-and single-implant-retained mandibular overdentures with conventional or mini implants.

    PubMed

    Pisani, Marina Xavier; Presotto, Anna Gabriella Camacho; Mesquita, Marcelo Ferraz; Barão, Valentim Adelino Ricardo; Kemmoku, Daniel Takanori; Del Bel Cury, Altair Antoninha

    2018-04-24

    The use of single or mini dental implants to retain mandibular overdentures is still questionable. The purpose of this finite element analysis (FEA) study was to investigate the biomechanical behavior of 2- and single-implant-retained mandibular overdentures with conventional or mini implants. Four 3-dimensional (3D) finite element models were constructed with the following designs of mandibular overdentures: 2 (group 2-C) and single (group 1-C) conventional external hexagon implants with ball or O-ring attachment and 2 (group 2-M) and single (group 1-M) 1-piece mini implants. A 150-N axial load was applied bilaterally and simultaneously on the first molar. Overdenture displacement, von Mises equivalent stress (implants and/or prosthetic components), and maximum principal stresses (peri-implant bone) were recorded numerically and then color-coded and compared among the groups. The overdenture displacement (in mm) was higher for the 1-M (0.16) and 2-M (0.17) groups when compared with 1-C (0.09) and 2-C (0.08). Irrespective of the type of implant, the single-implant groups presented higher values of stress (in MPa) on the implants than did the 2-implant groups (1-C=52.53; 1-M=2.95; 2-C=34.66; 2-M=2.37), ball attachment (1-C=201.33; 2-C=159.06), housing or O-ring (1-C=125.01; 1-M=1.96; 2-C=88.84; 2-M=1.27), and peri-implant cortical bone (1-C=19.37; 1-M=1.47; 2-C=15.70; 2-M=1.06). The mini implant overdentures presented lower stress values on the implants, housing or O-ring, and peri-implant bone than did the conventional implant overdentures, regardless of the number of implants. The 2-implant-retained overdentures exhibited lower stresses than the single- implant-retained overdentures, irrespective of the type of implant. The mini implants demonstrated higher overdenture displacement and lower stresses than did conventional implant overdentures for single- and 2-implant-retained overdentures. Copyright © 2018 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Metallic orthopaedic implants and airport metal detectors.

    PubMed

    Kamineni, S; Legge, S; Ware, H

    2002-01-01

    Airport security can detect in vivo metallic implants. We hypothesized that a soft tissue shield and fast transit through archway detectors would decrease implant detectability, whereas greater implant mass would increase detectability. Twelve patients with 8 orthopaedic implants in vivo and 60 trauma and arthroplasty implants in vitro were subjected to standard airport security measures at Stanstead Airport (British Airports Authority), including arch and standard and nonstandard hand-held detectors. Archway detectors failed to detect some implants; hand-held detectors detected almost all implants except an ankle arthroplasty. Positive archway detection was related to implant transit speed through the detection field. The implant mass consistently affected detection in stainless steel and titanium implants, and a 1-inch wax shield had no effect. Patients with metallic implants should prepare routinely with documentation of their implant before traveling through security ports.

  20. Bone morphology changes around two types of bone-level implants installed in fresh extraction sockets--a histomorphometric study in Beagle dogs.

    PubMed

    Alharbi, Hend M; Babay, Nadir; Alzoman, Hamad; Basudan, Sumaya; Anil, Sukumaran; Jansen, John A

    2015-09-01

    Minimizing crestal bone loss following immediate implant placement is considered the most challenging aspect in implant therapy. Implant surface topography and chemical modifications have been shown to influence the success of Osseointegration. The Straumann Bone Level implant, featuring SLActive surface, has been introduced with the aim of enhancing bone apposition. Similarly, the OsseoSpeed implants from Astra Tech claim to have an enhanced osseointegration. Because of the specific features in the implant design, both companies claim that crestal resorption is minimal with these implants. To evaluate the osseointegration and crestal bone level following immediate placement of Straumann Bone Level implant and OsseoSpeed implants in fresh extraction sockets in Beagle dogs. The distal roots of the second, third and fourth premolars were extracted in both sides of the mandible. The distal roots were removed using a dental elevator. A total of 60 fixtures were installed in 10 Beagle dogs. Two types of implants were used: Straumann Bone-Level implants, which were 8 × 3.3 mm in size, and Astra Tech OsseoSpeed 3.5 S MicroThread implants, which were 8 × 3.5 mm in size. The histomorphometrical evaluation was performed at the end of 4- and 12-week healing. The implant-bone contact and bone volume percentage were assessed. The bone-to-implant contact (BIC) and the bone volume did not show any significant changes for both types of implants. The OsseoSpeed™ implants showed 67.4% and 65.3% BIC, respectively, at 4 and 12 weeks compared with 71.7 and 73.1 for the Straumann Bone-Level implants. The bone volume around both types of implants did not differ significantly at both time periods. The crestal bone resorption was observed for both types of implants. The first BIC at buccal side and lingual side of the implants also did not differ significantly for both implant systems. This study showed that Straumann Bone Level and OsseoSpeed implants induced similar bone response after immediate implantation at 4 and 12 weeks. The immediate implant placement resulted in peri-implant crestal bone-level changes for both types of implants. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Effect of implant macro-design on primary stability: A prospective clinical study.

    PubMed

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Gargallo-Albiol, Jordi; Hernández-Alfaro, Federico

    2016-03-01

    Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Mehods: A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers' standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability.

  2. Restoration of reproductive potential after expiration or removal of melengestrol acetate contraceptive implants in Tigers (Panthera tigris).

    PubMed

    Chuei, Jason Y; Asa, Cheryl S; Hall-Woods, Monica; Ballou, Jonathon; Traylor-Holzer, Kathy

    2007-07-01

    The need for contraception in the successful management of captive wild animals is becoming increasingly apparent. Because concerns exist regarding the reversibility of the contraceptive implant melengestrol acetate (MGA), reproductive data for 94 female Amur (Panthera tigris altaica) and Sumatran tigers (Panthera tigris sumatrae) were analyzed using survival analyses to evaluate return to reproductive status after implant removal or assumed expiration. Females placed in potential breeding situations after MGA implants were surgically removed showed a 62% return to reproduction by 5.25 years, whereas females with implants that were assumed to have expired showed only a 30% return to reproduction by 6 years. Implanted females did not reproduce as successfully as non-implanted control females, which showed an 85% probability of reproducing after placement in a new breeding situation by 2.66 years. Parturition increased the probability of reproducing in non-implanted females, but not in implanted females. Litter size, stillbirths, and offspring survival were not significantly different between non-implanted, implant-removed and implant-expired female tigers. Ten female tigers reproduced both before and after implant placement, and the differences in litter size, stillbirths, and offspring survival were not significant, nor were they significantly different from non-implanted females. Prior parturition, age when implant was removed, and duration of implantation did not affect the probability of reproducing for females after implant removal. These results show substantial reversibility of MGA implants, leading to 62% successful reproduction after implant removal. The reasons for lower successful reproduction in animals previously treated with the contraceptive compared to non-implanted females are not known, but a greater delay in reversibility was seen when implants were left in place and only presumed expired. Zoo Biol 26:275-288, 2007. (c) 2007 Wiley-Liss, Inc.

  3. Poly Implants Prosthèse Breast Implants: A Case Series and Review of the Literature.

    PubMed

    Klein, Doron; Hadad, Eran; Wiser, Itay; Wolf, Omer; Itzhaki Shapira, Ortal; Fucks, Shir; Heller, Lior

    2018-01-01

    Silicone breast implants from the French manufacturer Poly Implants Prosthèse (PIP) were recalled from the European market after the French regulator has revealed the implants contain non-medical-grade silicone filler. In December 2011, following a large increase in reported rupture rate and a possible cancer risk, the French Ministry of Health recommended consideration of the PIP explantation, regardless of their condition. In 2012, the Israel Ministry of Health recommended to replace the implants only upon suspected implant rupture. The aims of this study were to characterize breast-augmented Israeli patients with PIP implants, compare their outcomes with those of breast-augmented patients with different implant types, and review the current PIP literature. Breast-augmented patients who underwent an elective breast implant exchange in Israel between January 2011 and January 2017 were included in the study. Data were collected from electronic and physical medical files. There were 73 breast-augmented female patients with 146 PIP breast implants included in this study. Average implant age was 6.7 ± 2.79 years. Mean implant size was 342.8 ± 52.9 mL. Fourteen women (19 implants [16%]) had a high-grade capsular contracture (Baker grade 3-4). During exchange, 28 implants were found to be ruptured (19.2%). Less than 10 years following breast augmentation, PIP implants demonstrated higher rupture rate compared with other implants. Our data are comparable to overall available rupture rate. Among patients with definitive rupture diagnosis, an elective implant removal should be recommended. In cases of undamaged implants, plastic surgeons should also seriously consider PIP implant explantation. When the patient does not desire to remove the implant, an annual physical examination and breast ultrasound are recommended, beginning a year after augmentation.

  4. Macro design effects on stress distribution around implants: a photoelastic stress analysis.

    PubMed

    Ozkir, Serhat Emre; Terzioglu, Hakan

    2012-01-01

    Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants. In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Straumann AG, Basel, Switzerland), stepped cylinder (Frialit2, Friadent GmbH, Manheim, Germany), root form (Camlog Rootline, Alatatec, Wilshelm, Germany), and cylindrical implant, with micro-threads on the implant neck (Astra, AstraTech, Mölndal, Sweden). In the test models, one of the implants was inserted straight, while the other one was aligned mesially with 15° angles. The superstructures were prepared as single crowns. A 150N loading was applied to the restorations throughout the test. A comparison of the implant designs showed that there were no significant differences between the straight implants; however, between the inclined implants, the most favorable stress distribution was seen with the stepped cylinder implants. The least favorable stress concentration was observed around the root formed implants. Microthreads around the implant neck appeared to be effective in a homogenous stress distribution. Observations showed that misaligned implants caused less stress than straight implants, but the stress concentrations were not homogenous. As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.

  5. Number of implants for mandibular implant overdentures: a systematic review

    PubMed Central

    Lee, Jeong-Yol; Kim, Ha-Young; Bryant, S. Ross

    2012-01-01

    PURPOSE The aim of this systematic review is to address treatment outcomes of Mandibular implant overdentures relative to implant survival rate, maintenance and complications, and patient satisfaction. MATERIALS AND METHODS A systematic literature search was conducted by a PubMed search strategy and hand-searching of relevant journals from included studies. Randomized Clinical Trials (RCT) and comparative clinical trial studies on mandibular implant overdentures until August, 2010 were selected. Eleven studies from 1098 studies were finally selected and data were analyzed relative to number of implants. RESULTS Six studies presented the data of the implant survival rate which ranged from 95% to 100% for 2 and 4 implant group and from 81.8% to 96.1% for 1 and 2 implant group. One study, which statistically compared implant survival rate showed no significant differences relative to the number of implants. The most common type of prosthetic maintenance and complications were replacement or reattaching of loose clips for 2 and 4 implant group, and denture repair due to the fracture around an implant for 1 and 2 implant groups. Most studies showed no significant differences in the rate of prosthetic maintenance and complication, and patient satisfaction regardless the number of implants. CONCLUSION The implant survival rate of mandibular overdentures is high regardless of the number of implants. Denture maintenance is likely not inflenced substantially by the number of implants and patient satisfaction is typically high again regardless os the number of implants. PMID:23236572

  6. Stability of tapered and parallel-walled dental implants: A systematic review and meta-analysis.

    PubMed

    Atieh, Momen A; Alsabeeha, Nabeel; Duncan, Warwick J

    2018-05-15

    Clinical trials have suggested that dental implants with a tapered configuration have improved stability at placement, allowing immediate placement and/or loading. The aim of this systematic review and meta-analysis was to evaluate the implant stability of tapered dental implants compared to standard parallel-walled dental implants. Applying the guidelines of Preferred Reporting Items for Systematic Reviews and Meta-analyses (PRISMA) statement, randomized controlled trials (RCTs) were searched for in electronic databases and complemented by hand searching. The risk of bias was assessed using the Cochrane Collaboration's Risk of Bias tool and data were analyzed using statistical software. A total of 1199 studies were identified, of which, five trials were included with 336 dental implants in 303 participants. Overall meta-analysis showed that tapered dental implants had higher implant stability values than parallel-walled dental implants at insertion and 8 weeks but the difference was not statistically significant. Tapered dental implants had significantly less marginal bone loss compared to parallel-walled dental implants. No significant differences in implant failure rate were found between tapered and parallel-walled dental implants. There is limited evidence to demonstrate the effectiveness of tapered dental implants in achieving greater implant stability compared to parallel-walled dental implants. Superior short-term results in maintaining peri-implant marginal bone with tapered dental implants are possible. Further properly designed RCTs are required to endorse the supposed advantages of tapered dental implants in immediate loading protocol and other complex clinical scenarios. © 2018 Wiley Periodicals, Inc.

  7. Indications of Free Grafts in Mandibular Reconstruction, after Removing Benign Tumors: Treatment Algorithm

    PubMed Central

    Alister, Juan Pablo; Uribe, Francisca; Olate, Sergio; Arriagada, Alvaro

    2016-01-01

    Background: Mandibular reconstruction has been the subject of much debate and research in the fields of maxillofacial surgery and head and neck surgery. Materials and Methods: A retrospective observational study was undertaken with 14 patients diagnosed with benign tumorous pathologies and who underwent immediate mandibular resection and reconstruction at the Hospital del Salvador Maxillofacial Surgery Unit and Dr. Rodrigo Fariña’s private clinic between the years 2002 and 2012. We propose a treatment algorithm, which is previous teeth extractions in area that will be removed. Results: Fourteen patients underwent surgery, and a total of 40 dental implants were installed in 6 men and 8 women, the mean age of 33.5 (age range, 14–58 y). Reconstruction with iliac crest bone graft, and rehabilitation following this protocol (average of reconstruction was 8.7 cm), was successful with no complications at all in 12 patients. One patient had a minor complication, and the graft was partially reabsorbed because of communication of the graft with the oral cavity. This complication did not impede rehabilitation with dental implants. Another patient suffered the total loss of the graft due to infection because of dehiscence of oral mucosa and great communication with the mouth. Another iliac crest free graft reconstruction was undertaken 6 months later. Conclusions: The scientific evidence suggests that mandibular reconstruction using free grafts following the removal of benign tumors is a biologically sustainable alternative. The critical factor to improve the prognosis of free grafts reconstruction in benign tumors is to have good quality soft tissue and avoid communication with the oral cavity. For this, it is vital to do dental extractions before removing the tumor. PMID:27622113

  8. The effect of microgeometry, implant thickness and polyurethane chemistry on the foreign body response to subcutaneous implants.

    PubMed

    Ward, W Kenneth; Slobodzian, Emily P; Tiekotter, Kenneth L; Wood, Michael D

    2002-11-01

    We addressed the effect of implant thickness, implant porosity, and polyurethane (PU) chemistry on angiogenesis and on the foreign body response in rats. The following materials were implanted subcutaneously for 7 weeks then excised for histologic analysis: a solid PU; a solid polyurethane with silicone and polyethylene oxide (PU-S-PEO); porous expanded polytetrafluoroethylene (ePTFE); and porous polyvinyl alcohol sponge (PVA). Two thicknesses of PU-S-PEO were compared: 300 microns (thin) and 2000 microns (thick). Foreign body capsule (FBC) thickness was much less in PU-S-PEO implants than in PU implants. In addition, FBC were thinner in thin implants than in thick implants. FBC was much more dense in solid implants than in porous implants. As compared with solid implants, porous implants (PVA and ePTFE) led to a marked increase in the number of microvessels that developed adjacent to the implant, as observed both with hematoxylin/eosin staining and with an immunohistochemical anti-endothelial stain. We conclude that the polyethylene oxide and silicone moieties in PU reduce the thickness of the subsequent FBC. In addition, thin implants lead to a thin FBC. Porous implants (PVA and ePTFE) cause more angiogenesis than solid implants. These results may have implications for the measurement of blood-derived analytes by biosensors.

  9. Comparative silicone breast implant evaluation using mammography, sonography, and magnetic resonance imaging: experience with 59 implants.

    PubMed

    Ahn, C Y; DeBruhl, N D; Gorczyca, D P; Shaw, W W; Bassett, L W

    1994-10-01

    With the current controversy regarding the safety of silicone implants, the detection and evaluation of implant rupture are causing concern for both plastic surgeons and patients. Our study obtained comparative value analysis of mammography, sonography, and magnetic resonance imaging (MRI) in the detection of silicone implant rupture. Twenty-nine symptomatic patients (total of 59 silicone implants) were entered into the study. Intraoperative findings revealed 21 ruptured implants (36 percent). During physical examination, a positive "squeeze test" was highly suggestive of implant rupture. Mammograms were obtained of 51 implants (sensitivity 11 percent, specificity 89 percent). Sonography was performed on 57 implants (sensitivity 70 percent, specificity 92 percent). MRI was performed on 55 implants (sensitivity 81 percent, specificity 92 percent). Sonographically, implant rupture is demonstrated by the "stepladder sign." Double-lumen implants may appear as false-positive results for rupture on sonography. On MRI, the "linguine sign" represents disrupted fragments of a ruptured implant. The most reliable imaging modality for implant rupture detection is MRI, followed by sonogram. Mammogram is the least reliable. Our study supports the clinical indication and diagnostic value of sonogram and MRI in the evaluation of symptomatic breast implant patients.

  10. Influence of immediate loading on provisional restoration in dental implant stability

    NASA Astrophysics Data System (ADS)

    Ikbal, M.; Odang, R. W.; Indrasari, M.; Dewi, R. S.

    2017-08-01

    The success of dental implant treatment is determined by the primary stability at placement. One factor that could influence this stability is occlusal loading through provisional restoration. Two types of loading protocols are usually used: immediate and delayed loading. However, some controversies remain about the influence of occlusal loading on implant stability. Therefore, the influence of immediate loading on implant stability must be studied. An animal study was conducted by placing nine dental implants in the mandibular jaw of three Macaca fascicularis. Provisional restorations with various occlusal contacts (no, light, and normal contact) were placed on the implant. The implant stability was measured using the Ostell ISQ three times: immediately (baseline) and at the first and second months after implant placement. The implant stability between implants with no and normal occlusal contact as well as light and normal occlusal contact showed significant differences (p < 0.05) at the first and second months after implant placement. However, no significant increase (p > 0.05) in implant stability was seen at the baseline and the first and second months after implant placement for all occlusal contact groups. Immediate loading influenced the implant stability, and provisional restoration of implant without occlusal contact showed the highest implant stability.

  11. Clinical Management of Implant Prostheses in Patients with Bruxism

    PubMed Central

    Komiyama, Osamu; Lobbezoo, Frank; De Laat, Antoon; Iida, Takashi; Kitagawa, Tsuyoshi; Murakami, Hiroshi; Kato, Takao; Kawara, Misao

    2012-01-01

    There is general agreement that excessive stress to the bone-implant interface may result in implant overload and failure. Early failure of the implant due to excessive loading occurs shortly after uncovering the implant. Excess load on a final restoration after successful implant integration can result in physical failure of the implant structure. Many clinicians believe that overload of dental implants is a risk factor for vertical peri-implant bone loss and/or may be detrimental for the suprastructure in implant prostheses. It has been documented that occlusal parafunction, such as, bruxism (tooth grinding and clenching) affects the outcome of implant prostheses, but there is no evidence for a causal relation between the failures and overload of dental implants. In spite of this lack of evidence, often metal restorations are preferred instead of porcelain for patients in whom bruxism is presumed on the basis of tooth wear. The purpose of this paper is to discuss the importance of the occlusal scheme used in implant restorations for implant longevity and to suggest a clinical approach and occlusal materials for implant prostheses in order to prevent complications related to bruxism. PMID:22701484

  12. Spectral-Temporal Modulated Ripple Discrimination by Children With Cochlear Implants.

    PubMed

    Landsberger, David M; Padilla, Monica; Martinez, Amy S; Eisenberg, Laurie S

    A postlingually implanted adult typically develops hearing with an intact auditory system, followed by periods of deafness (or near deafness) and adaptation to the implant. For an early implanted child whose brain is highly plastic, the auditory system matures with consistent input from a cochlear implant. It is likely that the auditory system of early implanted cochlear implant users is fundamentally different than postlingually implanted adults. The purpose of this study is to compare the basic psychophysical capabilities and limitations of these two populations on a spectral resolution task to determine potential effects of early deprivation and plasticity. Performance on a spectral resolution task (Spectral-temporally Modulated Ripple Test [SMRT]) was measured for 20 bilaterally implanted, prelingually deafened children (between 5 and 13 years of age) and 20 hearing children within the same age range. Additionally, 15 bilaterally implanted, postlingually deafened adults, and 10 hearing adults were tested on the same task. Cochlear implant users (adults and children) were tested bilaterally, and with each ear alone. Hearing listeners (adults and children) were tested with the unprocessed SMRT and with a vocoded version that simulates an 8-channel cochlear implant. For children with normal hearing, a positive correlation was found between age and SMRT score for both the unprocessed and vocoded versions. Older hearing children performed similarly to hearing adults in both the unprocessed and vocoded test conditions. However, for children with cochlear implants, no significant relationship was found between SMRT score and chronological age, age at implantation, or years of implant experience. Performance by children with cochlear implants was poorer than performance by cochlear implanted adults. It was also found that children implanted sequentially tended to have better scores with the first implant compared with the second implant. This difference was not observed for adults. An additional finding was that SMRT score was negatively correlated with age for adults with implants. Results from this study suggest that basic psychophysical capabilities of early implanted children and postlingually implanted adults differ when assessed in the sound field using their personal implant processors. Because spectral resolution does not improve with age for early implanted children, it seems likely that the sparse representation of the signal provided by a cochlear implant limits spectral resolution development. These results are supported by the finding that postlingually implanted adults, whose auditory systems matured before the onset of hearing loss, perform significantly better than early implanted children on the spectral resolution test.

  13. Effect of implant macro-design on primary stability: A prospective clinical study

    PubMed Central

    Lozano-Carrascal, Naroa; Salomó-Coll, Oscar; Gilabert-Cerdà, Marta; Farré-Pagés, Nuria; Hernández-Alfaro, Federico

    2016-01-01

    Background Implant restorations have become a high predictable treatment option. Several caracteristics such as surgical technique and implant design can influence the treatment outcomes. The aim of the present study was to evaluate the influence of implant macro-design on primary stability measured with resonance frequency analysis (RFA) and insertion torque (IT). Material and Methods A total of 47 implants divided in two groups: Test group (TI): 22 Tapered MIS® Seven implants; Control group (CI): 25 cylindrical Astra® Osseospeed implants. All implants were inserted following the manufacturers’ standard protocols. Implant primary stability was measured at the moment of implant placement by registering insertion torque values (ITv) and ISQ values by means of Osstell™ Mentor (ISQv) (Integration Diagnostic Ltd., Goteborg, Sweden). Results In the mandible, mean ISQv for tapered implants (TI) was 71.67±5.16 and for cylindrical implants (CI) 57.15±4.83 (p=0.01). Mean insertion torque was 46.67±6.85 Ncm for TI and 35.77±6.72 Ncm for CI (p=0.01). In the maxilla, mean ISQ was 67.2±4.42 for tapered implants and 49.17±15.30 for cylindrical implants (p=0.01). Mean insertion torque for TI was 41.5±6.26 Ncm and for CI 39.17±6.34 Ncm (p>0.05). For tapered implants, no correlation could be found between implant diameter and primary stability. But for cylindrical implants there was a statistically significant correlation between implant diameter and primary stability: ITv (p=0.03); ISQv (p=0.04). Conclusions Within the limits of the present study, tapered shaped implants achieve higher primary stability measured through ISQ and insertion torque values. Moreover, for cylindrical implants positive correlation has been established between implant diameter and primary stability. Key words:Primary stability, tapered, cylindrical, conical, implant macro-design. PMID:26827067

  14. Effect of implant number and distribution on load transfer in implant-supported partial fixed dental prostheses for the anterior maxilla: A photoelastic stress analysis study.

    PubMed

    Lee, Jae-In; Lee, Yoon; Kim, Yu-Lee; Cho, Hye-Won

    2016-02-01

    The 4-, 3- or even 2-implant-supported partial fixed dental prosthesis (PFDP) designs have been used to rehabilitate the anterior edentulous maxilla. The purpose of this in vitro study was to compare the stress distribution in the supporting tissues surrounding implants placed in the anterior maxilla with 5 PFDP designs. A photoelastic model of the human maxilla with an anterior edentulous region was made with photoelastic resin (PL-2; Vishay Micro-Measurements), and 6 straight implants (OsseoSpeed; Astra Tech AB) were placed in the 6 anterior tooth positions. The 5 design concepts based on implant location were as follows: model 6I: 6 implants; model 2C2CI: 4 implants (2 canines and 2 central incisors); model 2C2LI: 4 implants (2 canines and 2 lateral incisors); model 2C1CI: 3 implants (2 canines and 1 central incisor); and model 2C: 2 canines. A load of 127.4 N was applied on the cingulum of 3 teeth at a 30-degree angle to the long axis of the implant. Stresses that developed in the supporting structure were recorded photographically. The 6-implant-supported PFDP exhibited the most even and lowest distribution of stresses in all loading conditions. When the canine was loaded, the 2- or 3-implant-supported PFDP showed higher stresses around the implant at the canine position than did the 4- or 6-implant-supported PFDP. When the central incisor or lateral incisor was loaded, the two 4-implant-supported PFDPs exhibited similar levels of stresses around the implants and showed lower stresses than did the 2- or 3-implant-supported PFDP. Implant number and distribution influenced stress distribution around the implants in the anterior maxilla. With a decrease in implant number, the stresses around the implants increased. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  15. United Kingdom national paediatric bilateral project: Demographics and results of localization and speech perception testing.

    PubMed

    Cullington, H E; Bele, D; Brinton, J C; Cooper, S; Daft, M; Harding, J; Hatton, N; Humphries, J; Lutman, M E; Maddocks, J; Maggs, J; Millward, K; O'Donoghue, G; Patel, S; Rajput, K; Salmon, V; Sear, T; Speers, A; Wheeler, A; Wilson, K

    2017-01-01

    To assess longitudinal outcomes in a large and varied population of children receiving bilateral cochlear implants both simultaneously and sequentially. This observational non-randomized service evaluation collected localization and speech recognition in noise data from simultaneously and sequentially implanted children at four time points: before bilateral cochlear implants or before the sequential implant, 1 year, 2 years, and 3 years after bilateral implants. No inclusion criteria were applied, so children with additional difficulties, cochleovestibular anomalies, varying educational placements, 23 different home languages, a full range of outcomes and varying device use were included. 1001 children were included: 465 implanted simultaneously and 536 sequentially, representing just over 50% of children receiving bilateral implants in the UK in this period. In simultaneously implanted children the median age at implant was 2.1 years; 7% were implanted at less than 1 year of age. In sequentially implanted children the interval between implants ranged from 0.1 to 14.5 years. Children with simultaneous bilateral implants localized better than those with one implant. On average children receiving a second (sequential) cochlear implant showed improvement in localization and listening in background noise after 1 year of bilateral listening. The interval between sequential implants had no effect on localization improvement although a smaller interval gave more improvement in speech recognition in noise. Children with sequential implants on average were able to use their second device to obtain spatial release from masking after 2 years of bilateral listening. Although ranges were large, bilateral cochlear implants on average offered an improvement in localization and speech perception in noise over unilateral implants. These data represent the diverse population of children with bilateral cochlear implants in the UK from 2010 to 2012. Predictions of outcomes for individual patients are not possible from these data. However, there are no indications to preclude children with long inter-implant interval having the chance of a second cochlear implant.

  16. Influence of trabecular bone quality and implantation direction on press-fit mechanics.

    PubMed

    Damm, Niklas B; Morlock, Michael M; Bishop, Nicholas E

    2017-02-01

    Achieving primary stability of uncemented press-fit prostheses in patients with poor quality bone can involve axial implantation forces large enough to cause bone fracture. Radial implantation eliminates intraoperative impaction forces and could prevent this damage. Platens of two commercial implant surfaces ("Beaded" and "Flaked") were implanted onto trabecular bone specimens of varying quality in a press-fit simulator. Samples were implanted with varying interference, either axially (shear) or radially (normal). Push-in and pull-out forces were measured to assess stability. Microstructural changes in the bone were determined from μCT analysis. For force-defined implantation analysis, push-in and pull-out forces both increased proportionally with increasing radial force, independent of implantation direction, bone quality or implant surface. For position-defined implantation analysis, pull-out forces were generally found to increase with interference and to be greater for radial than axial implantation direction, and to be lower for poor quality bone. Bone density increased locally at the tested interface due to implantation, in particular for the Beaded surface under axial implantation. If a safe radial stress can be determined for cortical bone in a particular patient, the associated implantation force, and pull-out force which represents primary stability, can be directly derived, regardless of implantation direction, bone quality or implant surface. Radial implantation delivers primary stability that is no worse than that for axial implantation and may eliminate potentially damaging impaction forces. Development of implant designs based on this principal might improve implant fixation. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:224-233, 2017. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  17. Chemical, corrosion and topographical analysis of stainless steel implants after different implantation periods.

    PubMed

    Chrzanowski, Wojciech; Armitage, David Andrew; Knowles, Jonathan Campbell; Szade, Jacek; Korlacki, Wojciech; Marciniak, Jan

    2008-07-01

    The aim of this work is to examine the corrosion properties, chemical composition, and material-implant interaction after different periods of implantation of plates used to correct funnel chest. The implants are made of 316L stainless steel. Examinations are carried out on three implants: new (nonimplanted) and two implanted for 29 and 35 months. The corrosion study reveals that in the potential range that could occur in the physiological condition the new bar has the lowest current density and the highest corrosion potential. This indicates that the new plate has the highest corrosion resistance and the corrosion resistance could be reduced during implantation by the instruments used during the operation. XPS analysis reveals changes in the surface chemistry. The longer the implantation time the more carbon and oxygen are observed and only trace of elements such as Cr, Mo are detected indicating that surface is covered by an organic layer. On some parts of the implants whitish tissue is observed: the thickness of which increased with the time of implantation. This tissue was identified as an organic layer; mainly attached to the surface on the areas close to where the implant was bent to attain anatomical fit and thus where the implant has higher surface roughness. The study indicates that the chest plates are impaired by the implantation procedure and contact with biological environment. The organic layer on the surface shows that the implant did not stay passive but some reactions at the tissue-implant interface occurred. These reactions should be seen as positive, as it indicates that the implants were accepted by the tissues. Nevertheless, if the implants react, they may continue to release chromium, nickel, and other harmful ions long term as indicated by lower corrosion resistance of the implants following implantation.

  18. Are marginal bone levels and implant stability/mobility affected by single-stage platform switched dental implants? A comparative clinical study.

    PubMed

    Dursun, Erhan; Tulunoglu, Ibrahim; Canpınar, Pınar; Uysal, Serdar; Akalın, Ferda Alev; Tözüm, Tolga F

    2012-10-01

    The aim of this study was to evaluate short-term bone level and stability/mobility measurement alterations at platform switched (PS) and standard platform (SP) implants placed in mandibular premolar/molar regions using a single-stage protocol. Sixteen PS and 16 SP implants restorated with fixed prosthesis were included. Standard implant dimensions were used for both implant systems. After 3 months of osseointegration, implants were connected to abutments and final restorations were performed. Marginal bone loss was measured by standardized periapical radiographs. Implant stability/mobility was determined by resonance frequency analysis (RFA) and mobility measuring (MM) device values. Peri-implant parameters were evaluated with clinical periodontal indices and all parameters were assessed at baseline, 1, 3, and 6 months after the surgery. After 6 months, all implants showed uneventful healing. Radiographic evaluation showed a mean bone loss of 0.72 mm for PS and 0.56 mm for SP implants, and there were no significant differences between implant types. At 6 months, mean implant stability quotient (ISQ) values were 73.38 and 77 for PS and SP implants, respectively. Mean MM values were -4.75 for PS and -6.38 for SP implants. Mean MM values were lower for SP implants compared to PS implants at all time points. No significant differences were detected between implant types according to clinical peri-implant parameters. The micro-gap at crestal level which immediately exposed to the oral cavity in non-submerged two part implants seems to have adverse influence on the marginal bone level. © 2011 John Wiley & Sons A/S.

  19. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis

    PubMed Central

    Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    ABSTRACT Objectives The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. Material and Methods A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. Results The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. Conclusions A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level. PMID:28496962

  20. Scalloped Implant-Abutment Connection Compared to Conventional Flat Implant-Abutment Connection: a Systematic Review and Meta-Analysis.

    PubMed

    Starch-Jensen, Thomas; Christensen, Ann-Eva; Lorenzen, Henning

    2017-01-01

    The objective was to test the hypothesis of no difference in implant treatment outcome after installation of implants with a scalloped implant-abutment connection compared to a flat implant-abutment connection. A MEDLINE (PubMed), Embase and Cochrane library search in combination with a hand-search of relevant journals was conducted. No language or year of publication restriction was applied. The search provided 298 titles. Three studies fulfilled the inclusion criteria. The included studies were characterized by low or moderate risk of bias. Survival of suprastructures has never been compared within the same study. High implant survival rate was reported in all the included studies. Significantly more peri-implant marginal bone loss, higher probing depth score, bleeding score and gingival score was observed around implants with a scalloped implant-abutment connection. There were no significant differences between the two treatment modalities regarding professional or patient-reported outcome measures. Meta-analysis disclosed a mean difference of peri-implant marginal bone loss of 1.56 mm (confidence interval: 0.87 to 2.25), indicating significant more bone loss around implants with a scalloped implant-abutment connection. A scalloped implant-abutment connection seems to be associated with higher peri-implant marginal bone loss compared to a flat implant-abutment connection. Therefore, the hypothesis of the present systematic review must be rejected. However, further long-term randomized controlled trials assessing implant treatment outcome with the two treatment modalities are needed before definite conclusions can be provided about the beneficial use of implants with a scalloped implant-abutment connection on preservation of the peri-implant marginal bone level.

  1. Biomechanical evaluation of one-piece and two-piece small-diameter dental implants: In-vitro experimental and three-dimensional finite element analyses.

    PubMed

    Wu, Aaron Yu-Jen; Hsu, Jui-Ting; Chee, Winston; Lin, Yun-Te; Fuh, Lih-Jyh; Huang, Heng-Li

    2016-09-01

    Small-diameter dental implants are associated with a higher risk of implant failure. This study used both three-dimensional finite-element (FE) simulations and in-vitro experimental tests to analyze the stresses and strains in both the implant and the surrounding bone when using one-piece (NobelDirect) and two-piece (NobelReplace) small-diameter implants, with the aim of understanding the underlying biomechanical mechanisms. Six experimental artificial jawbone models and two FE models were prepared for one-piece and two-piece 3.5-mm diameter implants. Rosette strain gauges were used for in-vitro tests, with peak values of the principal bone strain recorded with a data acquisition system. Implant stability as quantified by Periotest values (PTV) were also recorded for both types of implants. Experimental data were analyzed statistically using Wilcoxon's rank-sum test. In FE simulations, the peak value and distribution of von-Mises stresses in the implant and bone were selected for evaluation. In in-vitro tests, the peak bone strain was 42% lower for two-piece implants than for one-piece implants. The PTV was slightly lower for one-piece implants (PTV = -6) than for two-piece implants (PTV = -5). In FE simulations, the stresses in the bone and implant were about 23% higher and 12% lower, respectively, for one-piece implants than those for two-piece implants. Due to the higher peri-implant bone stresses and strains, one-piece implants (NobelDirect) might be not suitable for use as small-diameter implants. Copyright © 2016. Published by Elsevier B.V.

  2. Survival of dental implants placed in sites of previously failed implants.

    PubMed

    Chrcanovic, Bruno R; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-11-01

    To assess the survival of dental implants placed in sites of previously failed implants and to explore the possible factors that might affect the outcome of this reimplantation procedure. Patients that had failed dental implants, which were replaced with the same implant type at the same site, were included. Descriptive statistics were used to describe the patients and implants; survival analysis was also performed. The effect of systemic, environmental, and local factors on the survival of the reoperated implants was evaluated. 175 of 10,096 implants in 98 patients were replaced by another implant at the same location (159, 14, and 2 implants at second, third, and fourth surgeries, respectively). Newly replaced implants were generally of similar diameter but of shorter length compared to the previously placed fixtures. A statistically significant greater percentage of lost implants were placed in sites with low bone quantity. There was a statistically significant difference (P = 0.032) in the survival rates between implants that were inserted for the first time (94%) and implants that replaced the ones lost (73%). There was a statistically higher failure rate of the reoperated implants for patients taking antidepressants and antithrombotic agents. Dental implants replacing failed implants had lower survival rates than the rates reported for the previous attempts of implant placement. It is suggested that a site-specific negative effect may possibly be associated with this phenomenon, as well as the intake of antidepressants and antithrombotic agents. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Effect on Bone Architecture of Marginal Grooves in Dental Implants Under Occlusal Loaded Conditions in Beagle Dogs.

    PubMed

    Kato, Hatsumi; Kuroshima, Shinichiro; Inaba, Nao; Uto, Yusuke; Sawase, Takashi

    2018-02-01

    The aim of this study was to clarify whether marginal grooves on dental implants affect osseointegration, bone structure, and the alignment of collagen fibers to determine bone quality under loaded conditions. Anodized Ti-6Al-4V alloy dental implants, with and without marginal grooves (test and control implants, respectively), were used (3.7 × 8.0 mm). Fourth premolars and first molars of 6 beagle mandibles were extracted. Two control and test implants were placed in randomly selected healed sites at 12 weeks after tooth extraction. Screw-retained single crowns for first molars were fabricated. Euthanasia was performed at 8 weeks after the application of occlusal forces. Implant marginal bone level, bone to implant contact (BIC), bone structure around dental implants, and the alignment of collagen fibers determining bone quality were analyzed. The marginal bone level in test implants was significantly higher than that in control implants. Occlusal forces significantly increased BIC in test implants ( P = .007), whereas BIC did not change in control implants, irrespective of occlusal forces ( P = .303). Moreover, occlusal forces significantly increased BIC in test implants compared with control implants ( P = .032). Additionally, occlusal forces preferentially aligned collagen fibers in test implants, but not control implants. Hence, marginal grooves on dental implants have positive effects on increased osseointegration and adapted bone quality based on the preferential alignment of collagen fibers around dental implants under loaded conditions.

  4. Dental Implants in the Elderly Population: A Long-Term Follow-up.

    PubMed

    Compton, Sharon M; Clark, Danielle; Chan, Stephanie; Kuc, Iris; Wubie, Berhanu A; Levin, Liran

    The objectives of this study were to evaluate implant survival and success in the elderly population and to assess indicators and risk factors for success or failure of dental implants in older adults (aged 60 years and older). This historical prospective study was developed from a cohort of patients born prior to 1950 who received dental implants in a single private dental office. Implant survival and marginal bone levels were recorded and analyzed with regard to different patient- and implant-related factors. The study examined 245 patient charts and 1,256 implants from one dental clinic. The mean age at the time of implant placement was 62.18 ± 8.6 years. Smoking was reported by 9.4% of the cohort studied. The overall survival rate of the implants was 92.9%; 7.1% of the implants had failed. Marginal bone loss depicted by exposed threads was evident in 23.3% of the implants. Presenting with generalized periodontal disease and/or severe periodontal disease negatively influenced the survival probability of the implant. Implants placed in areas where bone augmentation was performed prior to or during implant surgery did not have the same longevity compared with those that did not have augmentation prior to implantation. The overall findings concluded that implants can be successfully placed in older adults. A variety of factors are involved in the long-term success of the implant, and special consideration should be taken prior to placing implants in older adults to limit the influence of those risk factors.

  5. What do sales data tell us about implant survival?

    PubMed

    Seemann, Rudolf; Jirku, Alexander; Wagner, Florian; Wutzl, Arno

    2017-01-01

    The aim of this study was to evaluate the influence of implant diameter, length and shape on a surrogate parameter of implant survival; i.e. the implant return rate in a big data analysis. A retrospective study was conducted and the factors influencing the success rates of 69,377 sold implants over a seven-year period were evaluated. The osseointegration program of a reseller provides reliable data of a single country. Implant loss rates were investigated using logistic regression models and regressed by implant type, diameter, and length. The return rate of 69,377 sold implants was 2.78% and comparable to implant loss rates in previous published prospective studies as its surrogate parameter. A total of 80% of implant returns had occurred within 157 days, and an additional 15% within 750.25 days. Diameters of 3.8 to 5.0mm showed the lowest return rates with its bottom in the 4.3mm implant whilst 6.0mm implants had significantly higher return rates. In comparison to the most sold implant length (13mm) shorter implants showed significantly higher early return rates. The study provides evidence that in cases of standard indications and sufficient bone, the use of screw typed dental implants with 3.8 or 4.3 diameter and 11 or 13 mm length shows the lowest implant return rates. Other implants may be selected only in specific indications.

  6. Impact of crestal and subcrestal implant placement in peri-implant bone: A prospective comparative study

    PubMed Central

    Pellicer-Chover, Hilario; Peñarrocha-Diago, María; Peñarrocha-Oltra, David; Gomar-Vercher, Sonia; Agustín-Panadero, Rubén

    2016-01-01

    Background To assess the influence of the crestal or subcrestal placement of implants upon peri-implant bone loss over 12 months of follow-up. Material and Methods Twenty-six patients with a single hopeless tooth were recruited in the Oral Surgery Unit (Valencia University, Valencia, Spain). The patients were randomized into two treatment groups: group A (implants placed at crestal level) or group B (implants placed at subcrestal level). Control visits were conducted by a trained clinician at the time of implant placement and 12 months after loading. A previously established standard protocol was used to compile general data on all patients (sex and age, implant length and diameter, and brushing frequency). Implant success rate, peri-implant bone loss and the treatment of the exposed implant surface were studied. The level of statistical significance was defined as 5% (α=0.05). Results Twenty-three patients (8 males and 15 females, mean age 49.8±11.6 years, range 28-75 years) were included in the final data analyses, while three were excluded. All the included subjects were nonsmokers with a brushing frequency of up to twice a day in 85.7% of the cases. The 23 implants comprised 10 crestal implants and 13 subcrestal implants. After implant placement, the mean bone position with respect to the implant platform in group A was 0.0 mm versus 2.16±0.88 mm in group B. After 12 months of follow-up, the mean bone positions were -0.06±1.11 mm and 0.95±1.50 mm, respectively - this representing a bone loss of 0.06±1.11 mm in the case of the crestal implants and of 1.22±1.06 mm in the case of the subcrestal implants (p=0.014). Four crestal implants and 5 subcrestal implants presented peri-implant bone levels below the platform, leaving a mean exposed treated surface of 1.13 mm and 0.57 mm, respectively. The implant osseointegration success rate at 12 months was 100% in both groups. Conclusions Within the limitations of this study, bone loss was found to be greater in the case of the subcrestal implants, though from the clinical perspective these implants presented bone levels above the implant platform after 12 months of follow-up. Key words:Immediate implants, tooth extraction, dental implants, single-tooth, crestal bone, placement level. PMID:26615504

  7. Presence of Biofilms on Polyurethane-Coated Breast Implants: Preliminary Results.

    PubMed

    Rieger, Ulrich M; Djedovic, Gabriel; Pattiss, Alexander; Raschke, Gregor F; Frei, Reno; Pierer, Gerhard; Trampuz, Andrej

    2016-01-01

    Polyurethane-coated breast implants seem to be associated with lower medium- and long-term capsular contracture rates in comparison to textured or smooth implant surfaces. Although the etiology of capsular contracture is uncertain, bacterial biofilms have been suggested to trigger chronic peri-implant inflammation, eventually leading to capsular contracture. It is unknown whether polyurethane-coated implants are less prone to biofilm colonization than other implant surfaces. We extracted data from patient records included in a prospective cohort between 2008 and 2011. All patients who underwent removal of polyurethane-coated implants were included in this current study and screened for presence of biofilms by sonication. In addition, implant- and patient-related data were analyzed. Of the ten included polyurethane-coated breast implants, six had been inserted for reconstructive purposes and four for aesthetic reasons. The median implant indwelling time was 28.3 mo. Overall, sonication cultures were positive in 50% of implants. Propionibacterium acnes and coagulase-negative staphylococci were the predominant pathogens isolated from biofilm cultures. Like other implant surfaces, polyurethane-coated implants are prone to biofilm colonization. Further investigations are needed to determine why capsular contracture rates seem to be lower in polyurethane implants than in other implant surfaces. Notably, in this study, 40% of the implants were explanted from breasts with severe capsular contracture.

  8. Single- and double- lumen silicone breast implant integrity: prospective evaluation of MR and US criteria.

    PubMed

    Berg, W A; Caskey, C I; Hamper, U M; Kuhlman, J E; Anderson, N D; Chang, B W; Sheth, S; Zerhouni, E A

    1995-10-01

    To evaluate the accuracy of magnetic resonance (MR) and ultrasound (US) criteria for breast implant integrity. One hundred twenty-two single-lumen silicone breast implants and 22 bilumen implants were evaluated with surface coil MR imaging and US and surgically removed. MR criteria for implant failure were a collapsed implant shell ("linguine sign"), foci of silicone outside the shell ("noose sign"), and extracapsular gel, US criteria were collapsed shell, low-level echoes within the gel, and "snowstorm" echoes of extracapsular silicone. Among single-lumen implants, MR imaging depicted 39 of 40 ruptures, 14 of 28 with minimal leakage; 49 of 54 intact implants were correctly interpreted. US depicted 26 of 40 ruptured implants, four of 28 with minimal leakage, and 30 of 54 intact implants. Among bilumen implants, MR imaging depicted four of five implants with rupture of both lumina and nine of 10 as intact; US depicted one rupture and helped identify two of 10 as intact. Mammography accurately depicted the status of 29 of 30 bilumen implants with MR imaging correlation. MR imaging depicts implant integrity more accurately than US; neither method reliably depicts minimal leakage with shell collapse. Mammography is useful in screening bilumen implant integrity.

  9. Role of clinician's experience and implant design on implant stability. An ex vivo study in artificial soft bones.

    PubMed

    Romanos, Georgios E; Basha-Hijazi, Abdulaziz; Gupta, Bhumija; Ren, Yan-Fang; Malmstrom, Hans

    2014-04-01

    Clinical experience in implant placement is important in order to prevent implant failures. However, the implant design affects the primary implant stability (PS) especially in poor quality bones. Therefore, the aim of this study was to compare the effect of clinician surgical experience on PS, when placing different type of implant designs. A total of 180 implants (90 parallel walled-P and 90 tapered-T) were placed in freshly slaughtered cow ribs. Bone quality was evaluated by two examiners during surgery and considered as 'type IV' bone. Implants (ø 5 mm, length: 15 mm, Osseotite, BIOMET 3i, Palm Beach Gardens, FL, USA) were placed by three different clinicians (master/I, good/II, non-experienced/III, under direct supervision of a manufacturer representative; 30 implants/group). An independent observer assessed the accuracy of placement by resonance frequency analysis (RFA) with implant stability quotient (ISQ) values. Two-way analysis of variance (ANOVA) and Tukey's post hoc test were used to detect the surgical experience of the clinicians and their interaction and effects of implant design on the PS. All implants were mechanically stable. The mean ISQ values were: 49.57(± 18.49) for the P-implants and 67.07(± 8.79) for the T-implants. The two-way ANOVA showed significant effects of implant design (p < .0001), clinician (p < .0001), and their interaction (p < .0001). The Tukey's multiple comparison test showed significant differences in RFA for the clinician group I/II (p = .015) and highly significant (p < .0001) between I/III and II/III. The P-implants presented (for I, II, and III) mean ISQ values 31.25/49.18/68.17 and the T-implants showed higher ISQ values, 70.15/62.08/68.98, respectively. Clinicians I and II did not show extreme differences for T-implants (p = .016). In contrast, clinician III achieved high ISQ values using P- and T-implants following the exact surgical protocol based on the manufacturer guidelines. T-implants provided high stability for experienced clinicians compared with P-implants. T-implants achieved greater PS than the P-implants. All clinicians consistently achieved PS; however, experienced clinicians achieved higher ISQ values with T-implants in poor quality bone. © 2012 Wiley Periodicals, Inc.

  10. Tilted orthodontic micro implants: a photoelastic stress analysis.

    PubMed

    Çehreli, Seçil; Özçırpıcı, Ayça Arman; Yılmaz, Alev

    2013-10-01

    The aim of this study was to examine peri-implant stresses around orthodontic micro implants upon torque-tightening and static load application by quasi-three-dimensional photoelastic stress analysis. Self-tapping orthodontic micro implants were progressively inserted into photoelastic models at 30, 45, 70, and 90 degrees and insertion torques were measured. Stress patterns (isochromatic fringe orders) were recorded by the quasi-three-dimensional photoelastic method using a circular polariscope after insertion and 250 g static force application. Torque-tightening of implants generated peri-implant stresses. Upon insertion, 90 degree placed implants displayed the lowest and homogeneous stress distribution followed by 30, 70, and 45 degree tilted implants. Static loading did not dramatically alter stress fields around the implants tested. The highest alteration in stress distribution was observed for the 90 degree placed implant, while 70 degree tilted implant had the lowest stresses among tilted implants. Torque-tightening of orthodontic micro implants creates a stress field that is not dramatically altered after application of static lateral moderate orthodontic loads, particularly at the cervical region of tilted implants.

  11. Prevalences of peri-implantitis and peri-implant mucositis: systematic review and meta-analysis.

    PubMed

    Lee, Chun-Teh; Huang, Yen-Wen; Zhu, Liang; Weltman, Robin

    2017-07-01

    Due to the inconsistent definitions, reporting methods and study characteristics, prevalences of peri-implant diseases significantly varied in studies. This study aimed to systematically analyze implant-based and subject-based prevalences of peri-implant diseases and assess clinical variables potentially affecting the prevalence. Electronic search of studies was conducted using MEDLINE (PubMed), EMBASE and Web of Science. Publication screening, data extraction, and quality assessment were performed. Clinical studies having an at least average three-year follow-up period were selected. The numbers of subjects and implants in the studies had to be equal to or more than thirty. Forty seven studies were selected and prevalences of peri-implant diseases were analyzed. Since heterogeneity existed in each outcome (I 2 =94.7, 95.7, 95.3, and 99.3 for implant-based and subject-based peri-implantitis and peri-implant mucositis, respectively), the random-effects model based on the DerSimonian and Laird method, which incorporate an estimate of heterogeneity in the weighting, was applied to obtain the pooled prevalence. Weighted mean implant-based and subject-based peri-implantitis prevalences were 9.25% (95% Confidence Interval (CI): [7.57, 10.93]) and 19.83% (CI [15.38, 24.27) respectively. Weighted mean implant-based and subject-based peri-implant mucositis prevalences were 29.48% (CI: [22.65, 36.32]) and 46.83% (CI: [38.30, 55.36]) respectively. Functional time and implant to subject ratio were associated with subject-based peri-implantitis prevalence, but not peri-implant mucositis prevalences. Peri-implant diseases were prevalent and prevalence of peri-implantitis increased over time. Prevalences of peri-implantitis and peri-implant mucositis might not be highly associated since the prevalences were influenced by distinct variables. The results should be carefully interpreted because of data heterogeneity. Peri-implant diseases affect a significant number of dental implants and patients. It is important to understand the difficulties in diagnosis of these diseases and risk factors which may be modified to reduce the potential for disease occurrence or progression. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Peri-implant diseases and conditions: Consensus report of workgroup 4 of the 2017 World Workshop on the Classification of Periodontal and Peri-Implant Diseases and Conditions.

    PubMed

    Berglundh, Tord; Armitage, Gary; Araujo, Mauricio G; Avila-Ortiz, Gustavo; Blanco, Juan; Camargo, Paulo M; Chen, Stephen; Cochran, David; Derks, Jan; Figuero, Elena; Hämmerle, Christoph H F; Heitz-Mayfield, Lisa J A; Huynh-Ba, Guy; Iacono, Vincent; Koo, Ki-Tae; Lambert, France; McCauley, Laurie; Quirynen, Marc; Renvert, Stefan; Salvi, Giovanni E; Schwarz, Frank; Tarnow, Dennis; Tomasi, Cristiano; Wang, Hom-Lay; Zitzmann, Nicola

    2018-06-01

    A classification for peri-implant diseases and conditions was presented. Focused questions on the characteristics of peri-implant health, peri-implant mucositis, peri-implantitis, and soft- and hard-tissue deficiencies were addressed. Peri-implant health is characterized by the absence of erythema, bleeding on probing, swelling, and suppuration. It is not possible to define a range of probing depths compatible with health; Peri-implant health can exist around implants with reduced bone support. The main clinical characteristic of peri-implant mucositis is bleeding on gentle probing. Erythema, swelling, and/or suppuration may also be present. An increase in probing depth is often observed in the presence of peri-implant mucositis due to swelling or decrease in probing resistance. There is strong evidence from animal and human experimental studies that plaque is the etiological factor for peri-implant mucositis. Peri-implantitis is a plaque-associated pathological condition occurring in tissues around dental implants, characterized by inflammation in the peri-implant mucosa and subsequent progressive loss of supporting bone. Peri-implantitis sites exhibit clinical signs of inflammation, bleeding on probing, and/or suppuration, increased probing depths and/or recession of the mucosal margin in addition to radiographic bone loss. The evidence is equivocal regarding the effect of keratinized mucosa on the long-term health of the peri-implant tissue. It appears, however, that keratinized mucosa may have advantages regarding patient comfort and ease of plaque removal. Case definitions in day-to-day clinical practice and in epidemiological or disease-surveillance studies for peri-implant health, peri-implant mucositis, and peri-implantitis were introduced. The proposed case definitions should be viewed within the context that there is no generic implant and that there are numerous implant designs with different surface characteristics, surgical and loading protocols. It is recommended that the clinician obtain baseline radiographic and probing measurements following the completion of the implant-supported prosthesis. © 2018 American Academy of Periodontology and European Federation of Periodontology.

  13. Fortifying the Bone-Implant Interface Part 2: An In Vivo Evaluation of 3D-Printed and TPS-Coated Triangular Implants

    PubMed Central

    Lindsey, Derek P.; Woods, Shane A.; Lalor, Peggy A.; Gundanna, Mukund I.; Yerby, Scott A.

    2017-01-01

    Background Minimally invasive surgical fusion of the sacroiliac (SI) joint using machined solid triangular titanium plasma spray (TPS) coated implants has demonstrated positive clinical outcomes in SI joint pain patients. Additive manufactured (AM), i.e. 3D-printed, fenestrated triangular titanium implants with porous surfaces and bioactive agents, such as nanocrystalline hydroxyapatite (HA) or autograft, may further optimize bony fixation and subsequent biomechanical stability. Methods A bilateral ovine distal femoral defect model was used to evaluate the cancellous bone-implant interfaces of TPS-coated and AM implants. Four implant groups (n=6/group/time-point) were included: 1)TPS-coated, 2)AM, 3)AM+HA, and 4)AM+Autograft. The bone-implant interfaces of 6- and 12-week specimens were investigated via radiographic, biomechanical, and histomorphometric methods. Results Imaging showed peri-implant bone formation around all implants. Push-out testing demonstrated forces greater than 2500 N, with no significant differences among groups. While TPS implants failed primarily at the bone-implant interface, AM groups failed within bone ~2-3mm away from implant surfaces. All implants exhibited bone ongrowth, with no significant differences among groups. AM implants had significantly more bone ingrowth into their porous surfaces than TPS-coated implants (p<0.0001). Of the three AM groups, AM+Auto implants had the greatest bone ingrowth into the porous surface and through their core (p<0.002). Conclusions Both TPS and AM implants exhibited substantial bone ongrowth and ingrowth, with additional bone through growth into the AM implants’ core. Overall, AM implants experienced significantly more bone infiltration compared to TPS implants. While HA-coating did not further enhance results, the addition of autograft fostered greater osteointegration for AM implants. Clinical Relevance Additive manufactured implants with a porous surface provide a highly interconnected porous surface that has comparatively greater surface area for bony integration. Results suggest this may prove advantageous toward promoting enhanced biomechanical stability compared to TPS-coated implants for SI joint fusion procedures. PMID:28765800

  14. Macro design morphology of endosseous dental implants.

    PubMed

    Sahiwal, Indira G; Woody, Ronald D; Benson, Byron W; Guillen, Guillermo E

    2002-05-01

    The identification of dental implant bodies in patients without available records is a considerable problem due to increased patient mobility and to the large number of implant systems with different designs. The purpose of this study was to document the designs of selected implants to help clinicians identify these implants from their radiographic images. More than 50 implant manufacturers were contacted and asked to provide implants with dimensions as close as possible to 3.75 mm (diameter) x 10 mm (length). Forty-four implants were donated, separated into threaded and non-threaded categories, and further sorted into tapered and non-tapered categories. The implants were examined visually, and features on the entire circumference and length of each implant were recorded and categorized as coronal, midbody, or apical. A series of tables describe the 44 implants according to coronal, midbody, and apical features. The results of this project offer dentists basic knowledge of the design of selected dental implants. Such knowledge can aid the radiographic identification of these implants.

  15. Ultrastructural investigation of intact orbital implant surfaces using atomic force microscopy.

    PubMed

    Choi, Samjin; Lee, Seung Jun; Shin, Jae-Ho; Cheong, Youjin; Lee, Hui-Jae; Paek, Joo Hee; Kim, Jae Sik; Jin, Kyung-Hyun; Park, Hun-Kuk

    2011-01-01

    This study examined the surface nanostructures of three orbital implants: nonporous poly(methyl methacrylate) (PMMA), porous aluminum oxide and porous polyethylene. The morphological characteristics of the orbital implants surfaces were observed by atomic force microscopy (AFM). The AFM topography, phase shift and deflection images of the intact implant samples were obtained. The surface of the nonporous PMMA implant showed severe scratches and debris. The surface of the aluminum oxide implant showed a porous structure with varying densities and sizes. The PMMA implant showed nodule nanostructures, 215.56 ± 52.34 nm in size, and the aluminum oxide implant showed crystal structures, 730.22 ± 341.02 nm in size. The nonporous PMMA implant showed the lowest roughness compared with other implant biomaterials, followed by the porous aluminum oxide implant. The porous polyethylene implant showed the highest roughness and severe surface irregularities. Overall, the surface roughness of orbital implants might be associated with the rate of complications and cell adhesion. Copyright © 2011 Wiley Periodicals, Inc.

  16. Implant and prosthesis movement after enucleation: a randomized controlled trial.

    PubMed

    Shome, Debraj; Honavar, Santosh G; Raizada, Kuldeep; Raizada, Deepa

    2010-08-01

    To evaluate implant and prosthesis movement after myoconjunctival enucleation and subsequent polymethyl methacrylate (PMMA) implantation, compared with the traditional enucleation with muscle imbrication using a PMMA implant and with enucleation accompanied by porous polyethylene implantation. Randomized, controlled, observer-masked, interventional study. One hundred fifty patients, equally and randomly allocated to the 3 groups. Group 1 consisted of patients in whom a PMMA implant was used after enucleation with muscle imbrication (traditional PMMA group). Group 2 consisted of patients in whom a PMMA implant was used after enucleation with a myoconjunctival technique (myoconjunctival PMMA group). Group 3 consisted of patients in whom a porous polyethylene implant was used after enucleation by the scleral cap technique (porous polyethylene group). Fifty patients were included in each group. Patients were allocated to 1 of the 3 groups using stratified randomization. Informed consent was obtained. Acrylic prostheses custom made by a trained ocularist were fitted 6 weeks after surgery in all patients. A masked observer measured implant and prosthesis movement 6 weeks after surgery using a slit-lamp device with real-time video and still photographic documentation. Analysis of implant and prosthesis movement was carried out using the Mann-Whitney U test, and a P value of < or =0.03 was considered significant. Complications including implant displacement and exposure also were noted. Implant and prosthesis movement. Myoconjunctival PMMA implant movement was better than the traditional PMMA implant (P = 0.001), but was similar to that of the porous polyethylene implant. Prosthesis movement with the myoconjunctival PMMA implant was better than that of either the traditional PMMA (P = 0.001) or porous polyethylene (P = 0.002) implants. Myoconjunctival enucleation technique with a PMMA implant provides statistically and clinically significantly better implant and prosthesis movement than the traditional PMMA implant and better prosthesis movement than the porous polyethylene implant. Copyright 2010 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  17. A prospective, split-mouth study comparing tilted implants with angulated connection versus conventional implants with angulated abutment.

    PubMed

    Van Weehaeghe, Manú; De Bruyn, Hugo; Vandeweghe, Stefan

    2017-12-01

    An angulation of the implant connection could overcome the problems related to angulated abutments. This study compares conventional implants with angulated abutment to tilted implants with an angulated connection. Twenty patients were treated in the edentulous mandible. In the posterior jaw locations, one conventional tilted implant with angulated abutment and one angulated implant without abutment were placed. In the anterior jaw, two conventional implants were placed, one with and one without abutment. Implants were immediately loaded and 3 months later, the final bridge (PFM or monolithic zirconia) was placed. After a follow-up of 48 months, 17 patients were available for clinical examination. The mean overall marginal bone loss (MBL) was 1.26 mm. No significant differences in implant survival, MBL, periodontal indices, patients' satisfaction, or complications was found between implants restored on abutment or implant level, between the posteriorly located angulated implant nor angulated abutment, and between both anterior implants with or without abutment. The posterior implants demonstrated less MBL compared to the anterior implants (P < .001). There was no significant difference in MBL between the implants restored with zirconia or PFM bridges (P = .294). Overall mean pocket depth was 2.83 mm. More plaque was found in the PFM group compared to the full-zirconia group, at the bridge (P = .042) and the implants (P = .029). There was no difference between both materials in pocket depth (P = .635) or bleeding (P = .821). One zirconia bridge fractured, two angulated abutment were replaced and four loose bridge screws connected to the angulated abutments had to be tightened. Patients were overall satisfied (4.74/5). An implant with angulated connection may results in a stronger connection but does not affect the marginal bone loss. No difference in MBL was seen between implants restored on abutment or implant level. Zirconia seems to reduce the amount of plaque. © 2017 Wiley Periodicals, Inc.

  18. One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

    PubMed

    Zembic, Anja; Tahmaseb, Ali; Jung, Ronald E; Wismeijer, Daniel

    2017-07-01

    To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla. Local guided bone regeneration (GBR) was allowed if the treatment did not compromise implant stability. Following 3 to 5 months of healing, implant-supported overdentures were inserted on two ball anchors. Implants and overdentures were assessed at 1, 2, 4, and 8 weeks after implant insertion and 2, 4, and 12 months after insertion of overdentures (baseline). Standardized radiographs were taken at implant loading and 1 year. Implant survival rates and bone loss were the primary outcomes. Nineteen patients (1 dropout) with 38 implants were evaluated at a mean follow-up of 1.1 years (range 1.0-1.7 years). One implant failed resulting in an implant survival rate of 97.3%. There was a significant peri-implant bone loss of the implants at 1 year of function (mean, 0.7 mm, SD = 1.1 mm; median: 0.48 mm, IQR = 0.56 mm). There was a high 1-year implant survival rate for edentulous patients receiving 2 maxillary implants and ball anchors as overdenture support. However, several implants exhibited an increased amount of bone loss of more than 2 mm. Overdentures supported by 2 maxillary implants should thus be used with caution as minimally invasive treatment for specific patients encountering problems with their upper dentures until more long-term data is available. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Periotest values of implants placed in sockets augmented with calcium phosphosilicate putty graft: a comparative analysis against implants placed in naturally healed sockets.

    PubMed

    Mahesh, Lanka; Narayan, Tv; Kostakis, Georgios; Shukla, Sagrika

    2014-03-01

    To measure implant stability using periotest values of implants placed in sockets augmented with calcium phospho-silicate putty (CPS Putty) as compared with implant stability in naturally healed sockets. Twenty two sockets were implanted with CPS Putty immediately after extraction. The sockets were re-entered after a healing period at 5 to 6 months (average 5.3 months) for implant placement. Periotest values were recorded during implant insertion to assess primary stability. These were compared with the Periotest values of 26 implants placed in 22 patients, with naturally healed sockets. Periotest values were significantly lower in the grafted group, indicating better implant stability in sites grafted with CPS putty. Implant stability seems to be significantly higher in sockets augmented using CPS putty when compared to nongrafted sites. This suggests that socket grafting with CPS putty may enhance the quality of available bone for implantation.

  20. Oral rehabilitation with tilted dental implants: A metaanalysis

    PubMed Central

    Peñarrocha-Oltra, David; Candel-Marti, Eugenia; Peñarrocha-Diago, Maria

    2012-01-01

    Objective: To compare the course of patients treated with tilted implants versus those treated conventionally with axial implants, analyzing the success rate and marginal bone loss. Material and Methods: A PubMed search was made using the key words “tilted implants”, “angled implants”, “angulated implants”, “inclined implants” and “maxillary atrophy.” A review was made of the articles published between 1999-2010. The inclusion criteria were the use of tilted implants, clinical series involving at least 10 patients, and a minimum follow-up of 12 months after prosthetic loading. The exclusion criteria were isolated clinical cases, studies with missing data, and publications in languages other than English or Spanish. The metaanalysis finally included 13 articles: 7 retrospective studies and 6 prospective studies. Results: On analyzing the success rate in the retrospective studies, two reported a higher success rate with tilted implants; one a higher success rate with axial implants; and two reported similar success rates with both implants. On analyzing the success rate in the prospective studies, two reported a higher success rate with tilted implants; two a higher success rate with axial implants; and two reported similar success rates with both implants. On examining marginal bone loss, three studies reported greater bone loss with axial implants and one with tilted implants. Conclusions: There was no evidence of differences in success rate between tilted and axial implants in either the prospective or retrospective studies subjected to review. The marginal bone loss observed with the tilted and axial implants likewise proved very similar. It thus can be deduced that tilted implants exhibit the same evolutive behavior as axial implants. Key words:Axial implants, tilted implants, maxillary atrophy, tilted implants. PMID:22322494

  1. Three-dimensional finite element analysis of stress distribution on different bony ridges with different lengths of morse taper implants and prosthesis dimensions.

    PubMed

    Toniollo, Marcelo Bighetti; Macedo, Ana Paula; Rodrigues, Renata Cristina Silveira; Ribeiro, Ricardo Faria; de Mattos, Maria da Gloria Chiarello

    2012-11-01

    This finite element analysis (FEA) compared stress distribution on different bony ridges rehabilitated with different lengths of morse taper implants, varying dimensions of metal-ceramic crowns to maintain the occlusal alignment. Three-dimensional FE models were designed representing a posterior left side segment of the mandible: group control, 3 implants of 11 mm length; group 1, implants of 13 mm, 11 mm and 5 mm length; group 2, 1 implant of 11 mm and 2 implants of 5 mm length; and group 3, 3 implants of 5 mm length. The abutments heights were 3.5 mm for 13- and 11-mm implants (regular), and 0.8 mm for 5-mm implants (short). Evaluation was performed on Ansys software, oblique loads of 365N for molars and 200N for premolars. There was 50% higher stress on cortical bone for the short implants than regular implants. There was 80% higher stress on trabecular bone for the short implants than regular implants. There was higher stress concentration on the bone region of the short implants neck. However, these implants were capable of dissipating the stress to the bones, given the applied loads, but achieving near the threshold between elastic and plastic deformation to the trabecular bone. Distal implants and/or with biggest occlusal table generated greatest stress regions on the surrounding bone. It was concluded that patients requiring short implants associated with increased proportions implant prostheses need careful evaluation and occlusal adjustment, as a possible overload in these short implants, and even in regular ones, can generate stress beyond the physiological threshold of the surrounding bone, compromising the whole system.

  2. Stress distribution of various designs of prostheses on short implants or standard implants in posterior maxilla: a three dimensional finite element analysis

    PubMed Central

    JOMJUNYONG, K.; RUNGSIYAKULL, P.; RUNGSIYAKULL, C.; AUNMEUNGTONG, W.; CHANTARAMUNGKORN, M.; KHONGKHUNTHIAN, P.

    2017-01-01

    SUMMARY Introduction. Although many previous studies have reported on the high success rate of short dental implants, prosthetic design still plays an important role in the long-term implant treatment results. This study aims to evaluate stress distribution characteristics involved with various prosthetic designs on standard implants or short implants in the posterior maxilla. Materials and methods. Six finite element models were simulated representing the missing first and second maxillary molars. A standard implant (PW+ implant: 5.0×10 mm) and a short implant (PW+ implant: 5.0×6.0 mm) were applied under the various prosthetic conditions. The peri-implant maximum bone stress (V on mises stress) was evaluated when 200 N 30° oblique load was applied. A type III bone was approximated and complete osseous integration was assumed. Results. Maximum Von mises stress was numerically located at the cortical bone around the implant neck in all models. In every standard implant model shows better stress distribution. Stress values and concentration area decreased in the cortical and cancellous bone when implants were splinted in both the standard and short implant models. With regard to the non-replacing second molar models found that the area of stress at the cortical bone around the first molar implant to be more intensive. Moreover, in the non-replacing second molar models, the stress also spread to the second pre-molar in both the standard and short implant models. Conclusions. The length of the implant and prosthetics designs both affect the stress value and distribution of stress to the cortical and cancellous bones around the implant. PMID:29682254

  3. Recall management of patients with Rofil Medical breast implants.

    PubMed

    Schott, Sarah; Bruckner, Thomas; Golatta, Michael; Wallwiener, Markus; Küffner, Livia; Mayer, Christine; Paringer, Carmen; Domschke, Christoph; Blumenstein, Maria; Schütz, Florian; Sohn, Christof; Heil, Joerg

    2014-07-01

    Some Rofil Medical breast implants are relabelled Poly Implant Prothèse (PIP) implants, and it is recommended that Rofil implants be managed in the same way as PIP implants. We report the results of a systematic recall of patients who had received Rofil implants. All patients who received Rofil implants at our centre were identified and invited for specialist consultation. In patients who opted for explantation, preoperative and intraoperative work-up was performed in accordance with national guidelines and analysed. In cases suspicious for rupture, an MRI scan was performed. Two-hundred and twenty-five patients (average age 56; range 28-80) received a total of 321 Rofil implants an average of 5.8 (range 1-11) years previously, 225/321 (70%) implants were used for reconstruction after breast cancer. A total of 43 implants were removed prior to 2011, mainly due to capsular contracture (CC). A total of 188 patients were still affected at the time of recall. Of the 188 patients, 115 (61%) attended for specialist consultation, of which 50 (44%) requested immediate implant removal. To date, 72 of 115 (63%) women attending consultation (38% of all affected) have chosen explantation, 66 of 72 (92%) opting for new implants. Of the 108 explanted implants, 25 (23%) had capsular rupture and 57 (53%) had implant bleeding. Preoperative clinical assessment was unreliable for predicting CC or rupture. The majority of patients attended for consultation and requested explantation. The quality of the explanted Rofil implants was comparable to PIP implants, with a higher rupture prevalence compared with other, non-affected implants. Nevertheless, the acceptance of breast implants for reimplantation remained high. Copyright © 2014 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  4. Macrotextured Breast Implants with Defined Steps to Minimize Bacterial Contamination around the Device: Experience in 42,000 Implants.

    PubMed

    Adams, William P; Culbertson, Eric J; Deva, Anand K; R Magnusson, Mark; Layt, Craig; Jewell, Mark L; Mallucci, Patrick; Hedén, Per

    2017-09-01

    Bacteria/biofilm on breast implant surfaces has been implicated in capsular contracture and breast implant-associated anaplastic large-cell lymphoma (ALCL). Macrotextured breast implants have been shown to harbor more bacteria than smooth or microtextured implants. Recent reports also suggest that macrotextured implants are associated with a significantly higher incidence of breast implant-associated ALCL. Using techniques to reduce the number of bacteria around implants, specifically, the 14-point plan, has successfully minimized the occurrence of capsular contracture. The authors hypothesize that a similar effect may be seen in reducing the risk of breast implant-associated ALCL. Pooled data from eight plastic surgeons assessed the use of macrotextured breast implants (Biocell and polyurethane) and known cases of breast implant-associated ALCL. Surgeon adherence to the 14-point plan was also analyzed. A total of 42,035 Biocell implants were placed in 21,650 patients; mean follow-up was 11.7 years (range, 1 to 14 years). A total of 704 polyurethane implants were used, with a mean follow-up of 8.0 years (range, 1 to 20 years). The overall capsular contracture rate was 2.2 percent. There were no cases of implant-associated ALCL. All surgeons routinely performed all 13 perioperative components of the 14-point plan; two surgeons do not routinely prescribe prophylaxis for subsequent unrelated procedures. Mounting evidence implicates the role of a sustained T-cell response to implant bacteria/biofilm in the development of breast implant-associated ALCL. Using the principles of the 14-point plan to minimize bacterial load at the time of surgery, the development and subsequent sequelae of capsular contracture and breast implant-associated ALCL may be reduced, especially with higher-risk macrotextured implants. Therapeutic, IV.

  5. Finite element analysis of a novel implant distribution to support maxillary overdentures.

    PubMed

    Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V

    2013-01-01

    To evaluate the biomechanics of a novel implant placement distribution and compare it with that of conventional maxillary overdenture support using three-dimensional finite element analysis (FEA). The application of zirconia implants in the context of this novel design was also evaluated. Detailed FEA models were created to analyze the loading responses of two different distributions of implants to support maxillary overdentures. The two implant distributions were as follows: the conventional design (D1) included four unsplinted implants in the premolar regions, whereas the novel design (D2) included one midpalatal implant, bilateral canine/premolar implants, and one anterior off-center crestal implant. Anatomical models were created with computed tomographic data and static loads were applied axially and obliquely. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated, including any denture displacement. Comparable stress and strain values were seen in the peri-implant bone for both designs. A significant decrease in the first principal stresses of D2 implants was observed with oblique loads. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. D2 displayed lower maximum displacement values than D1. Maximum tensile stresses in the zirconia implants for either design were well below their fracture strength. A novel four-implant distribution involving midpalatal and crestal implants may be an alternative to the conventional design used for maxillary overdentures. This is particularly relevant when anatomical considerations prevent the placement of four anterior crestal implants. Zirconia implants may also be a valid option for a selected group of patients or for those requesting metal-free restorations. Prospective clinical studies are required to confirm these in vitro results.

  6. Silicone gel breast implants: science and testing.

    PubMed

    Kinney, Brian M; Jeffers, Lynn L C; Ratliff, Gregory E; Carlisle, Dan A

    2014-07-01

    Since the first generation of breast implants, major design innovations, including consistency of the gel, palpability and thickness of the shell, and barrier materials in the shell, have been introduced. Surgeons have not had metrics to assess and compare available implants. Research at independent laboratories included 4 tests: gel elasticity (the gel's ability to retain its shape), gel compression fracture (the resistance to permanent gel deformation), gel-shell peel (the integration of the gel with shell as a cohesive unit), and morphological analysis. Sientra's round High-Strength Cohesive (HSC) experienced the least gel elasticity (5.805 mm), whereas Allergan's round implants experienced the most (7.465 mm). Among shaped implants, Allergan 410 experienced the least gel elasticity (3.242 mm), whereas the Sientra HSC+ implant experienced the most (4.270 mm). Sientra's round (36.32 lbf) and shaped (44.16 lbf) implants demonstrated the highest resistance to gel fracture, with Allergan's implants demonstrating the least among round (23.06 lbf) implants and Mentor Contour Profile Gel (CPG) among shaped (30.45 lbf) implants. For the gel-shell peel test, Sientra's implant required over 26% greater force than Allergan's implant and over 35% greater force than Mentor's implant. Sientra's shaped implants required more than double the peel force than Allergan 410 (119% greater) and Mentor CPG (130% greater). Morphological results showed Sientra's implants preserved structural integrity (-1.10% change). The initial findings show that these implant characteristics are individual factors to be considered separately and are not necessarily correlative. Further study of implants using these and other testing techniques will help clinicians choose between implants.

  7. CO2 laser surface treatment of failed dental implants for re-implantation: an animal study.

    PubMed

    Kasraei, Shahin; Torkzaban, Parviz; Shams, Bahar; Hosseinipanah, Seyed Mohammad; Farhadian, Maryam

    2016-07-01

    The aim of the present study was to evaluate the success rate of failed implants re-implanted after surface treatment with CO2 laser. Despite the widespread use of dental implants, there are many incidents of failures. It is believed that lasers can be applied to decontaminate the implant surface without damaging the implant. Ten dental implants that had failed for various reasons other than fracture or surface abrasion were subjected to CO2 laser surface treatment and randomly placed in the maxillae of dogs. Three failed implants were also placed as the negative controls after irrigation with saline solution without laser surface treatment. The stability of the implants was evaluated by the use of the Periotest values (PTVs) on the first day after surgery and at 1, 3, and 6 months post-operatively. The mean PTVs of treated implants increased at the first month interval, indicating a decrease in implant stability due to inflammation followed by healing of the tissue. At 3 and 6 months, the mean PTVs decreased compared to the 1-month interval (P < 0.05), indicating improved implant stability. The mean PTVs increased in the negative control group compared to baseline (P < 0.05). Independent t-test showed that the mean PTVs of treated implants were significantly lower than control group at 3 and 6 months after implant placement (P < 0.05). Based on the PTVs, re-implantation of failed implants in Jack Russell Terrier dogs after CO2 laser surface debridement is associated with a high success rate in terms of implant stability.

  8. Retrospective Analysis on Survival Rate, Template-Related Complications, and Prevalence of Peri-implantitis of 694 Anodized Implants Placed Using Computer-Guided Surgery: Results Between 1 and 10 Years of Follow-Up.

    PubMed

    Tallarico, Marco; Meloni, Silvio Mario

    To report survival rate, early surgical template-related complications, and prevalence of peri-implantitis of dental implants placed in private practices using computer-guided, template-assisted surgery and followed between 1 and 10 years. The present retrospective multicenter study evaluated data collected from fully or partially edentulous patients, with anodized-surface implants placed using computer-guided, template-assisted surgery between January 2006 and December 2015. The outcome measures were implant cumulative survival rate (CSR), early surgical complications involving the surgical template, and prevalence of peri-implantitis. A total of 694 implants were placed in 141 patients. Ten patients (7.1%) with 48 implants (6.9%) dropped out during the study period. One hundred seventeen patients, who received 121 surgical and prosthetic procedures, were treated according to a double-scan protocol, while the remaining 24 patients were treated by using the integrated treatment workflow. Most of the implants were immediately loaded (528 implants, 76.1%; 112 patients, 79.4%). Overall, 107 complete full-arch restorations (supported by four to eight implants each) were delivered in 103 patients (73%) with 595 implants (85.7%), while 13 single and 30 partial restorations (two to five implants each) were delivered in 38 patients (27%) with 99 implants (14.3%). Patients were followed for up to 10 years (mean: 58.2 months, range: 12 to 120 months). Implant- and patient-level CSR (Kaplan-Meier estimation) at the 10-year follow-up was 97.4% (95% CI: 1.0309 to 0.9161) and 92.1% (95% CI: 1.1575 to 0.6836), respectively. All failed implants were lost before definitive prosthesis delivery (early failure). Ten (7.1%) minor template-related complications were experienced and resolved chairside. Over the entire follow-up period, four patients (2.8%) with 12 implants (1.7%) showed signs of peri-implantitis at the 1- (four implants), 2- (four implants), and 4-year (four implants) visits. High long-term survival rates and low complications and prevalence of peri-implantitis were observed for a large cohort of anodized-surface implants placed in private practices. Further studies are needed to confirm these preliminary results.

  9. What do sales data tell us about implant survival?

    PubMed Central

    Seemann, Rudolf; Jirku, Alexander; Wagner, Florian; Wutzl, Arno

    2017-01-01

    Objective The aim of this study was to evaluate the influence of implant diameter, length and shape on a surrogate parameter of implant survival; i.e. the implant return rate in a big data analysis. Materials and methods A retrospective study was conducted and the factors influencing the success rates of 69,377 sold implants over a seven-year period were evaluated. The osseointegration program of a reseller provides reliable data of a single country. Implant loss rates were investigated using logistic regression models and regressed by implant type, diameter, and length. Results The return rate of 69,377 sold implants was 2.78% and comparable to implant loss rates in previous published prospective studies as its surrogate parameter. A total of 80% of implant returns had occurred within 157 days, and an additional 15% within 750.25 days. Diameters of 3.8 to 5.0mm showed the lowest return rates with its bottom in the 4.3mm implant whilst 6.0mm implants had significantly higher return rates. In comparison to the most sold implant length (13mm) shorter implants showed significantly higher early return rates. Conclusions The study provides evidence that in cases of standard indications and sufficient bone, the use of screw typed dental implants with 3.8 or 4.3 diameter and 11 or 13 mm length shows the lowest implant return rates. Other implants may be selected only in specific indications. PMID:28222128

  10. The Effects of Subcrestal Implant Placement on Crestal Bone Levels and Bone-to-Abutment Contact: A Microcomputed Tomographic and Histologic Study in Dogs.

    PubMed

    Fetner, Michael; Fetner, Alan; Koutouzis, Theofilos; Clozza, Emanuele; Tovar, Nick; Sarendranath, Alvin; Coelho, Paulo G; Neiva, Kathleen; Janal, Malvin N; Neiva, Rodrigo

    2015-01-01

    Implant design and the implant-abutment interface have been regarded as key influences on crestal bone maintenance over time. The aim of the present study was to determine crestal bone changes around implants placed at different depths in a dog model. Thirty-six two-piece dental implants with a medialized implant-abutment interface and Morse taper connection (Ankylos, Dentsply) were placed in edentulous areas bilaterally in six mongrel dogs. On each side of the mandible, three implants were placed randomly at the bone crest, 1.5 mm subcrestally, or 3.0 mm subcrestally. After 3 months, the final abutments were torqued into place. At 6 months, the animals were sacrificed and samples taken for microcomputed tomographic (micro-CT) and histologic evaluations. Micro-CT analysis revealed similar crestal or marginal bone loss among groups. Both subcrestal implant groups lost significantly less crestal and marginal bone than the equicrestal implants. Bone loss was greatest on the buccal of the implants, regardless of implant placement depth. Histologically, implants placed subcrestally were found to have bone in contact with the final abutment and on the implant platform. Implants with a centralized implant-abutment interface and Morse taper connection can be placed subcrestally without significant loss of crestal or marginal bone. Subcrestal placement of this implant system appears to be advantageous in maintaining bone height coronal to the implant platform.

  11. Comparison of the Explantation Rate of Poly Implant Prothèse, Allergan, and Pérouse Silicone Breast Implants within the First Four Years after Reconstructive Surgery before the Poly Implant Prothèse Alert by the French Regulatory Authority.

    PubMed

    Leduey, Alexandre; Mazouni, Chafika; Leymarie, Nicolas; Alkhashnam, Heba; Sarfati, Benjamin; Garbay, Jean-Rémi; Gaudin, Amélie; Kolb, Frédéric; Rimareix, Françoise

    2015-01-01

    Background. In March 2010, ANSM (Agence Nationale de Sécurité du Medicament), the French Medical Regulatory Authority, withdrew Poly Implant Prothèse (PIP) breast implants from the market due to the use of non-medical-grade silicone gel. The aim of this study was to compare the removal rate (and reasons thereof) of breast implants produced by different manufacturers before the ANSM alert. Materials and Methods. From October 2006 to January 2010, 652 women received 944 implants after breast cancer surgery at the Gustave Roussy Comprehensive Cancer Center, Paris (France). The complications and removal rates of the different implant brands used (PIP, Allergan, and Pérouse) were evaluated and compared. Results. PIP implants represented 50.6% of the used implants, Allergan 33.4%, and Pérouse 16%. The main reasons for implant removal were patient dissatisfaction due to aesthetic problems (43.2%), infection (22.2%), and capsular contracture (13.6%). Two years after implantation, 82% of Pérouse implants, 79% of PIP, and 79% of Allergan were still in situ. There was no difference in removal rate among implant brands. Conclusion. Before the ANSM alert concerning the higher rupture rate of PIP breast implants, our implant removal rate did not predict PIP implant failure related to the use of nonapproved silicone gel.

  12. Comparison of the Explantation Rate of Poly Implant Prothèse, Allergan, and Pérouse Silicone Breast Implants within the First Four Years after Reconstructive Surgery before the Poly Implant Prothèse Alert by the French Regulatory Authority

    PubMed Central

    Leduey, Alexandre; Mazouni, Chafika; Leymarie, Nicolas; Alkhashnam, Heba; Sarfati, Benjamin; Garbay, Jean-Rémi; Gaudin, Amélie; Kolb, Frédéric; Rimareix, Françoise

    2015-01-01

    Background. In March 2010, ANSM (Agence Nationale de Sécurité du Medicament), the French Medical Regulatory Authority, withdrew Poly Implant Prothèse (PIP) breast implants from the market due to the use of non-medical-grade silicone gel. The aim of this study was to compare the removal rate (and reasons thereof) of breast implants produced by different manufacturers before the ANSM alert. Materials and Methods. From October 2006 to January 2010, 652 women received 944 implants after breast cancer surgery at the Gustave Roussy Comprehensive Cancer Center, Paris (France). The complications and removal rates of the different implant brands used (PIP, Allergan, and Pérouse) were evaluated and compared. Results. PIP implants represented 50.6% of the used implants, Allergan 33.4%, and Pérouse 16%. The main reasons for implant removal were patient dissatisfaction due to aesthetic problems (43.2%), infection (22.2%), and capsular contracture (13.6%). Two years after implantation, 82% of Pérouse implants, 79% of PIP, and 79% of Allergan were still in situ. There was no difference in removal rate among implant brands. Conclusion. Before the ANSM alert concerning the higher rupture rate of PIP breast implants, our implant removal rate did not predict PIP implant failure related to the use of nonapproved silicone gel. PMID:26543648

  13. Short Implants: New Horizon in Implant Dentistry.

    PubMed

    Jain, Neha; Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-09-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration.

  14. Short Implants: New Horizon in Implant Dentistry

    PubMed Central

    Gulati, Manisha; Garg, Meenu; Pathak, Chetan

    2016-01-01

    The choice of implant length is an essential factor in deciding the survival rates of these implants and the overall success of the prosthesis. Placing an implant in the posterior part of the maxilla and mandible has always been very critical due to poor bone quality and quantity. Long implants can be placed in association with complex surgical procedures such as sinus lift and bone augmentation. These techniques are associated with higher cost, increased treatment time and greater morbidity. Hence, there is need for a less invasive treatment option in areas of poor bone quantity and quality. Data related to survival rates of short implants, their design and prosthetic considerations has been compiled and structured in this manuscript with emphasis on the indications, advantages of short implants and critical biomechanical factors to be taken into consideration when choosing to place them. Studies have shown that comparable success rates can be achieved with short implants as those with long implants by decreasing the lateral forces to the prosthesis, eliminating cantilevers, increasing implant surface area and improving implant to abutment connection. Short implants can be considered as an effective treatment alternative in resorbed ridges. Short implants can be considered as a viable treatment option in atrophic ridge cases in order to avoid complex surgical procedures required to place long implants. With improvement in the implant surface geometry and surface texture, there is an increase in the bone implant contact area which provides a good primary stability during osseo-integration. PMID:27790598

  15. Clinical outcomes of implant therapy in ectodermal dysplasia patients: a systematic review.

    PubMed

    Wang, Y; He, J; Decker, A M; Hu, J C; Zou, D

    2016-08-01

    The purpose of this review was to determine the outcome of oral function reconstruction in ectodermal dysplasia (ED) patients who have received dental implant therapy. A search was made of the PubMed and Web of Science databases; key words used were "(ectodermal dysplasia) AND (implant OR implants)", with supplementary retrieval key words "dental implant", "zygomatic implant", "anodontia", and "edentulous". Patient age, use of bone graft, implant site, type of implant, and survival rate of the implants were included in the subsequent data analysis. Forty-five articles published between 1988 and October 2015 were included in this analysis. The cases of a total of 96 patients were retrieved (22 children and 74 adults); these patients received a total of 701 implants. Fourteen implants were removed during a median follow-up time of 24 months. The 24-month implant survival rate was 97.9% in adult subjects and 98.6% in children. Sixty-eight percent of adult patients underwent bone augmentation prior to implant placement. Based on this review, dental implants are commonly used in the oral reconstruction of ED patients. However, long-term data on bone augmentation and implant success are needed, as well as additional clinical evidence on bone resorption, the esthetic outcomes of implant therapy, and physiological considerations in ED patients. Copyright © 2016 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  16. Three-dimensional finite element analyses of four designs of a high-strength silicon nitride implant.

    PubMed

    Lin, S; Shi, S; LeGeros, R Z; LeGeros, J P

    2000-01-01

    The effects of implant shape and size on the stress distribution around high-strength silicon nitride implants under vertical and oblique forces were determined using a three-dimensional finite element analysis. Finite element models were designed using as a basis the serial sections of the mandible. Using Auto-CAD software, the model simulated the placement of implants in the molar region of the left mandible. Results of the analyses demonstrated that mainly the implant root shape and the directions of bite forces influence the stress distributions in the supporting bone around each implant. Implant size is a lesser factor. The serrated implants presented a larger surface area to the bone than either the cylindrical or tapered implants, which resulted in lower compressive stress around the serrated implants. With increasing implant diameter and length, compressive stress decreased. The mean compressive stress distribution on the serrated implants was more flat (platykurtic) than on either the cylindrical or tapered implants. Results of studies on two load directions (vertical and oblique) showed that, in either case, the compressive stress in the cortical bone around the neck of the implant was higher than in the cancellous bone along the length of the implant. The most extreme principal compressive stress was found with oblique force. This study provides the first information on the relationship between shape of the silicon nitride implant and stress on the supporting bone.

  17. Maxillary overdentures supported by four splinted direct metal laser sintering implants: a 3-year prospective clinical study.

    PubMed

    Mangano, Francesco; Luongo, Fabrizia; Shibli, Jamil Awad; Anil, Sukumaran; Mangano, Carlo

    2014-01-01

    Purpose. Nowadays, the advancements in direct metal laser sintering (DMLS) technology allow the fabrication of titanium dental implants. The aim of this study was to evaluate implant survival, complications, and peri-implant marginal bone loss of DMLS implants used to support bar-retained maxillary overdentures. Materials and Methods. Over a 2-year period, 120 implants were placed in the maxilla of 30 patients (18 males, 12 females) to support bar-retained maxillary overdentures (ODs). Each OD was supported by 4 implants splinted by a rigid cobalt-chrome bar. At each annual follow-up session, clinical and radiographic parameters were assessed. The outcome measures were implant failure, biological and prosthetic complications, and peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact, DIB). Results. The 3-year implant survival rate was 97.4% (implant-based) and 92.9% (patient-based). Three implants failed. The incidence of biological complication was 3.5% (implant-based) and 7.1% (patient-based). The incidence of prosthetic complication was 17.8% (patient-based). No detrimental effects on marginal bone level were evidenced. Conclusions. The use of 4 DMLS titanium implants to support bar-retained maxillary ODs seems to represent a safe and successful procedure. Long-term clinical studies on a larger sample of patients are needed to confirm these results.

  18. Maxillary Overdentures Supported by Four Splinted Direct Metal Laser Sintering Implants: A 3-Year Prospective Clinical Study

    PubMed Central

    Mangano, Francesco; Shibli, Jamil Awad; Anil, Sukumaran

    2014-01-01

    Purpose. Nowadays, the advancements in direct metal laser sintering (DMLS) technology allow the fabrication of titanium dental implants. The aim of this study was to evaluate implant survival, complications, and peri-implant marginal bone loss of DMLS implants used to support bar-retained maxillary overdentures. Materials and Methods. Over a 2-year period, 120 implants were placed in the maxilla of 30 patients (18 males, 12 females) to support bar-retained maxillary overdentures (ODs). Each OD was supported by 4 implants splinted by a rigid cobalt-chrome bar. At each annual follow-up session, clinical and radiographic parameters were assessed. The outcome measures were implant failure, biological and prosthetic complications, and peri-implant marginal bone loss (distance between the implant shoulder and the first visible bone-to-implant contact, DIB). Results. The 3-year implant survival rate was 97.4% (implant-based) and 92.9% (patient-based). Three implants failed. The incidence of biological complication was 3.5% (implant-based) and 7.1% (patient-based). The incidence of prosthetic complication was 17.8% (patient-based). No detrimental effects on marginal bone level were evidenced. Conclusions. The use of 4 DMLS titanium implants to support bar-retained maxillary ODs seems to represent a safe and successful procedure. Long-term clinical studies on a larger sample of patients are needed to confirm these results. PMID:25580124

  19. Short dental implants: an emerging concept in implant treatment.

    PubMed

    Al-Hashedi, Ashwaq Ali; Taiyeb Ali, Tara Bai; Yunus, Norsiah

    2014-06-01

    Short implants have been advocated as a treatment option in many clinical situations where the use of conventional implants is limited. This review outlines the effectiveness and clinical outcomes of using short implants as a valid treatment option in the rehabilitation of edentulous atrophic alveolar ridges. Initially, an electronic search was performed on the following databases: Medline, PubMed, Embase, Cochrane Database of Systematic Reviews, and DARE using key words from January 1990 until May 2012. An additional hand search was included for the relevant articles in the following journals: International Journal of Oral and Maxillofacial Implants, Clinical Oral Implants Research, Journal of Clinical Periodontology, International Journal of Periodontics, Journal of Periodontology, and Clinical Implant Dentistry and Related Research. Any relevant papers from the journals' references were hand searched. Articles were included if they provided detailed data on implant length, reported survival rates, mentioned measures for implant failure, were in the English language, involved human subjects, and researched implants inserted in healed atrophic ridges with a follow-up period of at least 1 year after implant-prosthesis loading. Short implants demonstrated a high rate of success in the replacement of missing teeth in especially atrophic alveolar ridges. The advanced technology and improvement of the implant surfaces have encouraged the success of short implants to a comparable level to that of standard implants. However, further randomized controlled clinical trials and prospective studies with longer follow-up periods are needed.

  20. Effects of pore size, implantation time and nano-surface properties on rat skin ingrowth into percutaneous porous titanium implants

    PubMed Central

    Farrell, Brad J.; Prilutsky, Boris I.; Ritter, Jana M.; Kelley, Sean; Popat, Ketul; Pitkin, Mark

    2013-01-01

    The main problem of percutaneous osseointegrated implants is poor skin-implant integration, which may cause infection. This study investigated the effects of pore size (Small, 40–100 microns and Large, 100–160 microns), nanotubular surface treatment (Nano), and duration of implantation (3 and 6 weeks) on skin ingrowth into porous titanium. Each implant type was percutaneously inserted in the back of 35 rats randomly assigned to 7 groups. Implant extrusion rate was measured weekly and skin ingrowth into implants was determined histologically after harvesting implants. It was found that all 3 types of implants demonstrated skin tissue ingrowth of over 30% (at week 3) and 50% (at weeks 4–6) of total implant porous area under the skin; longer implantation resulted in greater skin ingrowth (p<0.05). Only one case of infection was observed (infection rate 2.9%). Small and Nano groups showed the same implant extrusion rate which was lower than the Large group rate (0.06±0.01 vs. 0.16 ± 0.02 cm/week; p<0.05). Ingrowth area was comparable in the Small, Large and Nano implants. However, qualitatively, the Nano implants showed greatest cellular inhabitation within first three weeks. We concluded that percutaneous porous titanium implants allow for skin integration with the potential for a safe seal. PMID:23703928

  1. A retrospective study on clinical and radiological outcomes of oral implants in patients followed up for a minimum of 20 years.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2018-04-01

    Very long-term follow-up of oral implants is seldom reported in the literature. To assess oral implant failure rates and marginal bone loss (MBL) of patients followed up for a minimum of 20 years. Implants placed in patients followed up for 20+ years were included. Descriptive statistics, survival analyses, generalized estimating equations were performed. Three-hundred implants were randomly selected for MBL. 1,045 implants (227 patients) were included. Implant location, irradiation, and bruxism affected the implant survival rate. Thirty-five percent of the failures occurred within the first year after implantation, and another 26.8% in the second/third year. There was a cumulative survival rate of 87.8% after 36 years of follow-up. In the last radiological follow up, 35 implants (11.7%) had bone gain, and 35 implants (11.7%) presented at least 3 mm of MBL. Twenty-six out of 86 failed implants with available radiograms presented severe MBL in the last radiological register before implant failure. Most of the implant failures occurred at the first few years after implantation, regardless of a very long follow up. MBL can be insignificant in long-term observations, but it may, nevertheless, be the cause of secondary failure of oral implants in some cases. © 2017 Wiley Periodicals, Inc.

  2. Implant-bone interface stress distribution in immediately loaded implants of different diameters: a three-dimensional finite element analysis.

    PubMed

    Ding, Xi; Zhu, Xing-Hao; Liao, Sheng-Hui; Zhang, Xiu-Hua; Chen, Hong

    2009-07-01

    To establish a 3D finite element model of a mandible with dental implants for immediate loading and to analyze stress distribution in bone around implants of different diameters. Three mandible models, embedded with thread implants (ITI, Straumann, Switzerland) with diameters of 3.3, 4.1, and 4.8 mm, respectively, were developed using CT scanning and self-developed Universal Surgical Integration System software. The von Mises stress and strain of the implant-bone interface were calculated with the ANSYS software when implants were loaded with 150 N vertical or buccolingual forces. When the implants were loaded with vertical force, the von Mises stress concentrated on the mesial and distal surfaces of cortical bone around the neck of implants, with peak values of 25.0, 17.6 and 11.6 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains (5854, 4903, 4344 muepsilon) were located on the buccal cancellous bone around the implant bottom and threads of implants. The stress and strain were significantly lower (p < 0.05) with the increased diameter of implant. When the implants were loaded with buccolingual force, the peak von Mises stress values occurred on the buccal surface of cortical bone around the implant neck, with values of 131.1, 78.7, and 68.1 MPa for 3.3, 4.1, and 4.8 mm diameters, respectively, while the maximum strains occurred on the buccal surface of cancellous bone adjacent to the implant neck, with peak values of 14,218, 12,706, and 11,504 microm, respectively. The stress of the 4.1-mm diameter implants was significantly lower (p < 0.05) than those of 3.3-mm diameter implants, but not statistically different from that of the 4.8 mm implant. With an increase of implant diameter, stress and strain on the implant-bone interfaces significantly decreased, especially when the diameter increased from 3.3 to 4.1 mm. It appears that dental implants of 10 mm in length for immediate loading should be at least 4.1 mm in diameter, and uniaxial loading to dental implants should be avoided or minimized.

  3. Two-stage implant systems.

    PubMed

    Fritz, M E

    1999-06-01

    Since the advent of osseointegration approximately 20 years ago, there has been a great deal of scientific data developed on two-stage integrated implant systems. Although these implants were originally designed primarily for fixed prostheses in the mandibular arch, they have been used in partially dentate patients, in patients needing overdentures, and in single-tooth restorations. In addition, this implant system has been placed in extraction sites, in bone-grafted areas, and in maxillary sinus elevations. Often, the documentation of these procedures has lagged. In addition, most of the reports use survival criteria to describe results, often providing overly optimistic data. It can be said that the literature describes a true adhesion of the epithelium to the implant similar to adhesion to teeth, that two-stage implants appear to have direct contact somewhere between 50% and 70% of the implant surface, that the microbial flora of the two-stage implant system closely resembles that of the natural tooth, and that the microbiology of periodontitis appears to be closely related to peri-implantitis. In evaluations of the data from implant placement in all of the above-noted situations by means of meta-analysis, it appears that there is a strong case that two-stage dental implants are successful, usually showing a confidence interval of over 90%. It also appears that the mandibular implants are more successful than maxillary implants. Studies also show that overdenture therapy is valid, and that single-tooth implants and implants placed in partially dentate mouths have a success rate that is quite good, although not quite as high as in the fully edentulous dentition. It would also appear that the potential causes of failure in the two-stage dental implant systems are peri-implantitis, placement of implants in poor-quality bone, and improper loading of implants. There are now data addressing modifications of the implant surface to alter the percentage of osseointegration. New types of reinforcements for dental implants and the use of growth factors to augment bone regeneration so that implants can be placed more easily are now being actively investigated.

  4. Treatment of peri-implant diseases: a review of the literature and protocol proposal.

    PubMed

    Armas, Joshé; Culshaw, Shauna; Savarrio, Lee

    2013-01-01

    Over 100,000 implants were placed in the UK in 2010. As the numbers of patients with implant-retained prostheses increases, operators are encountering an increasing number of biological implant complications, most commonly peri-implant mucositis and peri-implantitis. The effective management of these complications is crucial to maintain patients' oral health. In particular, in contrast to common periodontal infections, some peri-implant infections may benefit from surgical intervention as a first line approach. This article reviews the literature on the treatment options for peri-implant mucositis and peri-implantitis and proposes a protocol for their treatment.

  5. The Key Points of Maintenance Therapy for Dental Implants: A Literature Review.

    PubMed

    Pirc, Miha; Dragan, Irina F

    2017-04-01

    Dental implants require lifelong maintenance and care. Success is defined by biologic factors (presence of inflamed soft tissues surrounding dental implants and radiographic changes in the crestal bone levels) and mechanical factors (stability of the implant fixture and implant supported restoration, etc). Most implant failures are initiated by incipient stages of inflammatory processes, which lead to peri-mucositis and peri-implantitis. The evidence regarding the value of maintenance protocol regarding implants is sparse compared with the one for teeth. This article addresses the existing literature on processes for oral hygiene for implant care.

  6. [Application of plasma sprayed zirconia coating in dental implant: study in implant].

    PubMed

    Huang, Z F; Wang, Z F; Li, C H; Hao, D; Lan, J

    2018-04-09

    Objective: To investigate the osseointegration of a novel coating-plasma-sprayed zirconia in dental implant. Methods: Zirconia coating on non-thread titanium implant was prepared using plasma spraying, the implant surface morphology, surface roughness and wettability were measured. In vivo , zirconia coated implants were inserted in rabbit tibia and animals were respectively sacrificed at 2, 4, 8 and 12 weeks after implantation. The bond strength between implant and bone was measured by push-out test. The osseointegration was observed by scanning electron microscopy (SEM), micro CT and histological analyses. Quantified parameters including removal torque, and bone-implant contact (BIC) percentage were calculated. Results: The surface roughness (1.6 µm) and wettability (54.6°) of zirconia coated implant was more suitable than those of titanium implant (0.6 µm and 74.4°) for osseointegration. At 12 weeks, the push-out value of zirconia coated implant and titanium implant were (64.9±3.0) and (50.4±2.9) N, and BIC value of these two groups were (54.7±3.6)% and (41.5±3.6)%. All these differences had statistical significance. Conclusions: The surface characters of zirconia coated implant were more suitable for osseointegration and present better osseointegration than smooth titanium implant in vivo , especially at early stage.

  7. The formation of an organic coat and the release of corrosion microparticles from metallic magnesium implants.

    PubMed

    Badar, Muhammad; Lünsdorf, Heinrich; Evertz, Florian; Rahim, Muhammad Imran; Glasmacher, Birgit; Hauser, Hansjörg; Mueller, Peter P

    2013-07-01

    Magnesium alloys have been proposed as prospective degradable implant materials. To elucidate the complex interactions between the corroding implants and the tissue, magnesium implants were analyzed in a mouse model and the response was compared to that induced by Ti and by the resorbable polymer polyglactin, respectively. One month after implantation, distinct traces of corrosion were apparent but the magnesium implants were still intact, whereas resorbable polymeric wound suture implants were already fragmented. Analysis of magnesium implants 2weeks after implantation by energy-dispersive X-ray spectroscopy indicated that magnesium, oxygen, calcium and phosphate were present at the implant surface. One month after implantation, the element composition of the outermost layer of the implant was indicative of tissue without detectable levels of magnesium, indicating a protective barrier function of this organic layer. In agreement with this notion, gene expression patterns in the surrounding tissue were highly similar for all implant materials investigated. However, high-resolution imaging using energy-filtered transmission electron microscopy revealed magnesium-containing microparticles in the tissue in the proximity of the implant. The release of such corrosion particles may contribute to the accumulation of calcium phosphate in the nearby tissue and to bone conductive activities of magnesium implants. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  8. Intracapsular implant rupture: MR findings of incomplete shell collapse.

    PubMed

    Soo, M S; Kornguth, P J; Walsh, R; Elenberger, C; Georgiade, G S; DeLong, D; Spritzer, C E

    1997-01-01

    The objective of this study was to determine the frequency and significance of the MR findings of incomplete shell collapse for detecting implant rupture in a series of surgically removed breast prostheses. MR images of 86 breast implants in 44 patients were studied retrospectively and correlated with surgical findings at explantation. MR findings included (a) complete shell collapse (linguine sign), 21 implants; (b) incomplete shell collapse (subcapsular line sign, teardrop sign, and keyhole sign), 33 implants; (c) radial folds, 31 implants; and (d) normal, 1 implant. The subcapsular line sign was seen in 26 implants, the teardrop sign was seen in 27 implants, and the keyhole sign was seen in 23 implants. At surgery, 48 implants were found to be ruptured and 38 were intact. The MR findings of ruptured implants showed signs of incomplete collapse in 52% (n = 25), linguine sign in 44% (n = 21), and radial folds in 4% (n = 2). The linguine sign perfectly predicted implant rupture, but sensitivity was low. Findings of incomplete shell collapse improved sensitivity and negative predictive values, and the subcapsular line sign produced a significant incremental increase in predictive ability. MRI signs of incomplete shell collapse were more common than the linguine sign in ruptured implants and are significant contributors to the high sensitivity and negative predictive values of MRI for evaluating implant integrity.

  9. Longer-term functional outcomes and everyday listening performance for young children through to young adults using bilateral implants.

    PubMed

    Galvin, Karyn Louise; Holland, Jennifer Frances; Hughes, Kathryn Clare

    2014-01-01

    First, to document a broad range of functional outcomes of bilateral implantation for young children through young adults at a postoperative point at which stable outcomes could be expected. Second, to evaluate the relationship between functional outcomes and age at bilateral implantation and time between implants. A study-specific questionnaire was administered to parents in an interview 3.5 years or more after sequential (n = 50) or simultaneous (n = 7) implants were received by their child. Median age at bilateral implantation was 4.1 years (range 0.7 to 19.8) and time between implants was 2.7 years (range 0.0 to 16.7). On the basis of parent report, 72% of the sequentially implanted children and young adults found it easy/only "a bit difficult" to adapt to the second implant, and were "happily wearing both implants together most of the time" by 6 months or before; 26% had not adapted, with both implants not worn most of the time or worn as a parental requirement. Seventy-two percent of sequentially implanted children and young adults had a positive attitude toward the second implant, including 9 whose early postoperative attitude was negative or neutral. The majority of children and young adults preferred bilateral implants (70%) and used the two full time (72%), while around half demonstrated similar performance with each implant alone. The proportion of nonusers or very minimal users of the second implant was just 9%. Eighty-eight percent of parents reported superior performance with bilateral versus a unilateral implant (n = 40), or that only bilateral implants were worn (n = 10) so performance could not be compared. The most commonly identified areas of superiority were localization, less need for repetition, and increased responsiveness. In balancing risks and costs with benefits, most parents (86%) considered the second implant worthwhile. Regarding the relationship between outcomes and demographic factors, the group achieving similar performance with each implant alone was younger at bilateral implantation and had less time between implants, and the group bilaterally implanted before 3.5 years of age (who also had less than 2 years between implants) had a higher proportion of positive outcomes on all functional outcome measures. Overall, the results indicate primarily positive functional outcomes for children and young adults receiving bilateral implants at all ages, including when the delay between implants is long. The results are important for evidence-based preoperative counseling, which helps families to make informed decisions and develop appropriate expectations. The results are also important for the development of clinical management practices that support and encourage the minority of recipients who have difficulty adapting to bilateral implants or achieving full-time use.

  10. Immediate provisionalization of dental implants placed in healed alveolar ridges and extraction sockets: a 5-year prospective evaluation.

    PubMed

    Cooper, Lyndon F; Reside, Glenn J; Raes, Filiep; Garriga, Joan Soliva; Tarrida, Luis Giner; Wiltfang, Jörg; Kern, Matthias; De Bruyn, Hugo

    2014-01-01

    This 5-year prospective multicenter study compared implant survival and success, peri-implant health and soft tissue responses, crestal bone level stability, and complication rates following immediate loading of single OsseoSpeed implants placed in anterior maxillary healed ridges or extraction sockets. Individuals requiring anterior tooth replacement with single implants were treated and immediately provisionalized. Definitive all-ceramic crowns were placed at 12 weeks. Implant survival, bone levels, soft tissue levels, and peri-implant health were monitored for 5 years. One hundred thirteen patients received implants in fresh sockets (55) and healed ridges (58). After 5 years, 45 and 49 patients remained for evaluation, respectively. During the first year, three implants failed in the extraction socket group (94.6% survival) and one implant failed in the healed ridge group (98.3% survival); this difference was not significant. No further implant failures were recorded. After 5 years, the interproximal crestal bone levels were located a mean of 0.43 ± 0.63 mm and 0.38 ± 0.62 mm from the reference points of implants in sockets and healed ridges (not a significant difference). In both groups, papillae increased over time and peri-implant mucosal zenith positions were stable from the time of definitive crown placement in sockets and healed ridges. Compared to flap surgery for implants in healed ridges, flapless surgery resulted in increased peri-implant mucosal tissue dimension (average, 0.78 ± 1.34 mm vs 0.19 ± 0.79 mm). After 5 years, the bone and soft tissue parameters that characterize implant success and contribute to dental implant esthetics were similar following the immediate provisionalization of implants in sockets and healed ridges. The overall tissue responses and reported implant survival support the immediate provisionalization of dental implants in situations involving healed ridges and, under ideal circumstances, extraction sockets.

  11. The Influence of the Crown-Implant Ratio on the Crestal Bone Level and Implant Secondary Stability: 36-Month Clinical Study.

    PubMed

    Hadzik, Jakub; Krawiec, Maciej; Sławecki, Konstanty; Kunert-Keil, Christiane; Dominiak, Marzena; Gedrange, Tomasz

    2018-01-01

    When the era of dental implantology began, the pioneers defined some gold standards used in dental prosthetics treatment for implant-supported restorations. Referring to traditional prosthetics, it was taken for granted that the length of an implant placed in the alveolar bone (the equivalent of the root) should exceed the length of the superstructure. The aim of the study was to determine whether implant length and the crown-to-implant ( C / I ) ratio influence implant stability and the loss of the surrounding marginal bone and whether short implants can be used instead of sinus augmentation procedures. The patients participating in the study ( n = 30) had one single tooth implant, a short (OsseoSpeed™ L6 Ø4 mm, Implants) or a regular implant (OsseoSpeed L11 and L13 Ø4 mm, DENTSPLY Implants), placed in the maxilla. The evaluation was based on clinical and radiological examination. The crown-to-implant ratio was determined by dividing the length of the crown together with the abutment by the length of the implant placed crestally. Mean crown-to-implant ratios were calculated separately for each group and its correlation with the MBL (marginal bone loss) and stability was assessed. The authors compared the correlation between the C / I ratio values, MBL, and secondary implant stability. Positive results in terms of primary and secondary stability were achieved with both (short and conventional) implants. The MBL was low for short and conventional implants being 0.34 ± 0.24 mm and 0.22 ± 0.46 mm, respectively. No significant correlation was found between the C / I ratio and secondary stability as well as the C / I ratio and the marginal bone loss. Short implants can be successfully used to support single crowns. The study has revealed no significant differences in the clinical performance of prosthetic restorations supported by short implants. Clinical trial registration number is NCT03471000.

  12. A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period

    PubMed Central

    2017-01-01

    Purpose The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque. PMID:28462009

  13. Short dental implants versus standard dental implants placed in the posterior jaws: A systematic review and meta-analysis.

    PubMed

    Lemos, Cleidiel Aparecido Araujo; Ferro-Alves, Marcio Luiz; Okamoto, Roberta; Mendonça, Marcos Rogério; Pellizzer, Eduardo Piza

    2016-04-01

    The purpose of the present systematic review and meta-analysis was to compare short implants (equal or less than 8mm) versus standard implants (larger than 8mm) placed in posterior regions of maxilla and mandible, evaluating survival rates of implants, marginal bone loss, complications and prosthesis failures. This review has been registered at PROSPERO under the number CRD42015016588. Main search terms were used in combination: dental implant, short implant, short dental implants, short dental implants posterior, short dental implants maxilla, and short dental implants mandible. An electronic search for data published up until September/2015 was undertaken using the PubMed/Medline, Embase and The Cochrane Library databases. Eligibility criteria included clinical human studies, randomized controlled trials and/or prospective studies, which evaluated short implants in comparison to standard implants in the same study. The search identified 1460 references, after inclusion criteria 13 studies were assessed for eligibility. A total of 1269 patients, who had received a total of 2631 dental implants. The results showed that there was no significant difference of implants survival (P=.24; RR:1.35; CI: 0.82-2.22), marginal bone loss (P=.06; MD: -0.20; CI: -0.41 to 0.00), complications (P=.08; RR:0.54; CI: 0.27-1.09) and prosthesis failures (P=.92; RR:0.96; CI: 0.44-2.09). Short implants are considered a predictable treatment for posterior jaws. However, short implants with length less than 8 mm (4-7 mm) should be used with caution because they present greater risks to failures compared to standard implants. Short implants are frequently placed in the posterior area in order to avoid complementary surgical procedures. However, clinicians need to be aware that short implants with length less than 8mm present greater risk of failures. Copyright © 2016. Published by Elsevier Ltd.

  14. 10-year survival rate and the incidence of peri-implant disease of 374 titanium dental implants with a SLA surface: a prospective cohort study in 177 fully and partially edentulous patients.

    PubMed

    van Velzen, Frank J J; Ofec, Ronen; Schulten, Engelbert A J M; Ten Bruggenkate, Christiaan M

    2015-10-01

    This prospective cohort study evaluates the 10-year survival and incidence of peri-implant disease at implant and patient level of sandblasted, large grid, and acid-etched titanium dental implants (Straumann, soft tissue level, SLA surface) in fully and partially edentulous patients. Patients who had dental implant surgery in the period between November 1997 and June 2001, with a follow-up of at least 10 years, were investigated for clinical and radiological examination. Among the 506 inserted dental implants in 250 patients, 10-year data regarding the outcome of implants were available for 374 dental implants in 177 patients. In the current study, peri-implantitis was defined as advanced bone loss (≧1.5 mm. postloading) in combination with bleeding on probing. At 10-year follow-up, only one implant was lost (0.3%) 2 months after implant surgery due to insufficient osseointegration. The average bone loss at 10 year postloading was 0.52 mm. Advanced bone loss at 10-year follow-up was present in 35 dental implants (9.8%). Seven percent of the observed dental implants showed bleeding on probing in combination with advanced bone loss and 4.2% when setting the threshold for advanced bone loss at 2.0 mm. Advanced bone loss without bleeding on probing was present in 2.8% of all implants. In this prospective study, the 10-year survival rate at implant and patient level was 99.7% and 99.4%, respectively. Peri-implantitis was present in 7% of the observed dental implants according to the above-mentioned definition of peri-implantitis. This study shows that SLA implants offer predictable long-term results as support in the treatment of fully and partially edentulous patients. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. A Longitudinal Study in Children with Sequential Bilateral Cochlear Implants: Time Course for the Second Implanted Ear and Bilateral Performance

    ERIC Educational Resources Information Center

    Reeder, Ruth M.; Firszt, Jill B.; Cadieux, Jamie H.; Strube, Michael J.

    2017-01-01

    Purpose: Whether, and if so when, a second-ear cochlear implant should be provided to older, unilaterally implanted children is an ongoing clinical question. This study evaluated rate of speech recognition progress for the second implanted ear and with bilateral cochlear implants in older sequentially implanted children and evaluated localization…

  16. Brief Assessment of Parental Perception (BAPP): Development and validation of a new measure for assessing paediatric outcomes after bilateral cochlear implantation.

    PubMed

    Samuel, V; Gamble, C; Cullington, H; Bathgate, F; Bennett, E; Coop, N; Cropper, J; Emond, A; Kentish, R; Edwards, L

    2016-11-01

    In contrast to previous clinical practice, current guidelines recommend bilateral cochlear implantation in children, resulting in a cohort of children who initially received one implant, but have subsequently had a second, contralateral implant. This study aimed to explore satisfaction and quality of life in children implanted simultaneously or sequentially. A novel measure of satisfaction and quality of life following paediatric bilateral cochlear implantation (the Brief Assessment of Parental Perception; BAPP) was developed and preliminary validation undertaken as part of a large, national project of bilateral implantation. Children's parents completed the measure yearly for up to three years following implantation. Children from 14 UK implant centres were recruited into the study; data were available for 410 children one year post-implantation. The BAPP was found to have good face and convergent validity, and internal consistency. Results indicated very high levels of satisfaction with the devices, and improvements in quality of life. However there was evidence that children implanted sequentially were less willing to wear their second implant in the first two years than those children receiving simultaneous implants. Simultaneous and sequential cochlear implants have a positive impact on the quality of life of deaf children.

  17. Hydroxyapatite ocular implant and non-integrated implants in eviscerated patients

    PubMed Central

    Gradinaru, S; Popescu, V; Leasu, C; Pricopie, S; Yasin, S; Ciuluvica, R; Ungureanu, E

    2015-01-01

    Introduction: This study compares the outcomes and complications of hydroxyapatite ocular implant and non-integrated ocular implants following evisceration. Materials and Methods: This is a retrospective study of 90 patients who underwent evisceration for different ocular affections, in the Ophthalmology Department of the University Emergency Hospital Bucharest, between January 2009 and December 2013. The outcomes measured were conjunctival dehiscence, socket infection, implant exposure and extrusion rate. Results: Forty-three patients had the hydroxyapatite implant (coralline–Integrated Ocular Implants, USA or synthetic–FCI, France) and forty-seven received non-integrated ocular implants (24 acrylic and 23 silicone). Five cases of socket infection, thirteen cases of extrusion and two cases of conjunctival dehiscence were encountered. Conclusions: There was a higher rate of conjunctival dehiscence with hydroxyapatite ocular implant, but implant extrusion and socket infection were found in non-integrated ocular implants. PMID:25914747

  18. DEALING WITH DENTAL IMPLANT FAILURES

    PubMed Central

    Levin, Liran

    2008-01-01

    An implant-supported restoration offers a predictable treatment for tooth replacement. Reported success rates for dental implants are high. Nevertheless, failures that mandate immediate implant removal do occur. The consequences of implant removal jeopardize the clinician's efforts to accomplish satisfactory function and esthetics. For the patient, this usually involves further cost and additional procedures. The aim of this paper is to describe different methods and treatment modalities to deal with dental implant failure. The main topics for discussion include identifying the failing implant, implants replacing failed implants at the exact site, and the use of other restorative options. When an implant fails, a tailor made treatment plan should be provided to each patient according to all relevant variables. Patients should be informed regarding all possible treatment modalities following implant failure and give their consent to the most appropriate treatment option for them. PMID:19089213

  19. Decontamination of dental implant surface in peri-implantitis treatment: A literature review

    PubMed Central

    Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.

    2013-01-01

    Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023

  20. Effect of phosphate treatment of Acid-etched implants on mineral apposition rates near implants in a dog model.

    PubMed

    Foley, Christine Hyon; Kerns, David G; Hallmon, William W; Rivera-Hidalgo, Francisco; Nelson, Carl J; Spears, Robert; Dechow, Paul C; Opperman, Lynne A

    2010-01-01

    This study evaluated the effects of phosphate coating of acid-etched titanium on the mineral apposition rate (MAR) and new bone-to-implant contact (BIC) in a canine model. Titanium implants (2.2 3 4 mm) with acid-etched surfaces that were electrolytically phosphated or not were placed in 48 mandibular sites in six foxhounds. Tetracycline and calcein dyes were administered 1 week after implant placement and 1 week before sacrifice. At 12 weeks after implant placement, the animals were sacrificed. MAR and BIC were evaluated using fluorescence microscopy. Light microscopic and histologic evaluations were performed on undecalcified sections. Microscopic evaluation showed the presence of healthy osteoblasts lining bone surfaces near implants. Similar BIC was observed in phosphated and nonphosphated titanium implant sites. MAR was significantly higher around the nonphosphated titanium implant surfaces than around the phosphated titanium samples. No significant differences were found between dogs or implant sites. Acid-etched implants showed significantly higher MARs compared to acid-etched, phosphate-coated implants. Int J Maxillofac Implants 2010;25:278-286.

  1. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants.

    PubMed

    Ersoy, Ahmet Ersan; Turkyilmaz, Ilser; Ozan, Oguz; McGlumphy, Edwin A

    2008-08-01

    Dental implant placement requires precise planning with regard to anatomic limitations and restorative goals. The aim of this study was to evaluate the match between the positions and axes of the planned and placed implants using stereolithographic (SLA) surgical guides. Ninety-four implants were placed using SLA surgical guides generated from computed tomography (CT) between 2005 and 2006. Radiographic templates were used for all subjects during CT imaging. After obtaining three-dimensional CT images, each implant was virtually placed on the CT images. SLA surgical guides, fabricated using an SLA machine with a laser beam to polymerize the liquid photo-polymerized resin, were used during implant placement. A new CT scan was taken for each subject following implant placement. Special software was used to fuse the images of the planned and placed implants, and the locations and axes were compared. Compared to the planned implants, the placed implants showed angular deviation of 4.9 degrees+/-2.36 degrees, whereas the mean linear deviation was 1.22+/-0.85 mm at the implant neck and 1.51+/-1 mm at the implant apex. Compared to the implant planning, the angular deviation and linear deviation at the neck and apex of the placed maxillary implants were 5.31 degrees+/-0.36 degrees, 1.04+/-0.56 mm, and 1.57+/-0.97 mm, respectively, whereas corresponding figures for placed mandibular implants were 4.44 degrees+/-0.31 degrees, 1.42+/-1.05 mm, and 1.44+/-1.03 mm, respectively. SLA surgical guides using CT data may be reliable in implant placement and make flapless implant placement possible.

  2. The clinical and diagnostic consequences of Poly Implant Prothèse silicone breast implants, recalled from the European market in 2010.

    PubMed

    Maijers, Maria C; Niessen, Francisus B

    2013-03-01

    Recently, Poly Implant Prothèse silicone breast implants were recalled from the European market. The authors studied 112 women and previously published data on rupture prevalence. Women are presenting with symptoms they feel may be a result of ruptured implants. The authors' aim was to study the clinical consequences of Poly Implant Prothèse implants. One hundred twelve women with 224 proven Poly Implant Prothèse implants after 10 years of implantation were enrolled in this study. All women underwent physical examination and magnetic resonance imaging and were interviewed regarding symptoms. Details of the explantations of 35 women with at least one ruptured implant were documented. Tissue from 10 women was sent for pathologic investigation. Of 112 women, 34 (30.4 percent) had symptoms attributable to their implants. Physical examination showed that 12 of the 121 women (10.7 percent) had findings suggestive of rupture, most commonly pain. Three had lymphadenopathy that seemed to correlate with implant rupture or excessive "gel bleed." Pathologic findings showed no malignancies. Eight women who underwent explantation had no implant rupture. Excessive gel bleed was documented in half of them. Clinical consequences of women with Poly Implant Prothèse implants are comparable to those reported in the literature of other manufacturers. Neither complaints nor findings at physical examination had a significant correlation with implant rupture at explantation. Magnetic resonance imaging is still the preferred method compared with physical examination for diagnosing rupture. The low specificity was probably caused by the difficulty in differentiating between rupture and excessive gel bleed in these implants.

  3. The influence of bone graft procedures on primary stability and bone change of implants placed in fresh extraction sockets.

    PubMed

    Jun, Sang Ho; Park, Chang-Joo; Hwang, Suk-Hyun; Lee, Youn Ki; Zhou, Cong; Jang, Hyon-Seok; Ryu, Jae-Jun

    2018-12-01

    This study was to evaluate the effect of bone graft procedure on the primary stability of implants installed in fresh sockets and assess the vertical alteration of peri-implant bone radiographically. Twenty-three implants were inserted in 18 patients immediately after tooth extraction. The horizontal gap between the implant and bony walls of the extraction socket was grafted with xenografts. The implant stability before and after graft procedure was measured by Osstell Mentor as implant stability quotient before bone graft (ISQ bbg) and implant stability quotient after bone graft (ISQ abg). Peri-apical radiographs were taken to measure peri-implant bone change immediately after implant surgery and 12 months after implant placement. Data were analyzed by independent t test; the relationships between stability parameters (insertion torque value (ITV), ISQ abg, and ISQ bbg) and peri-implant bone changes were analyzed according to Pearson correlation coefficients. The increase of ISQ in low primary stability group (LPSG) was 6.87 ± 3.62, which was significantly higher than the increase in high primary stability group (HPSG). A significant correlation between ITV and ISQ bbg ( R  = 0.606, P  = 0.002) was found; however, age and peri-implant bone change were not found significantly related to implant stability parameters. It was presented that there were no significant peri-implant bone changes at 1 year after bone graft surgery. Bone graft procedure is beneficial for increasing the primary stability of immediately placed implants, especially when the ISQ of implants is below 65 and that bone grafts have some effects on peri-implant bone maintenance.

  4. Revisiting the stability of mini-implants used for orthodontic anchorage.

    PubMed

    Yao, Chung-Chen Jane; Chang, Hao-Hueng; Chang, Jenny Zwei-Chieng; Lai, Hsiang-Hua; Lu, Shao-Chun; Chen, Yi-Jane

    2015-11-01

    The aim of this study is to comprehensively analyze the potential factors affecting the failure rates of three types of mini-implants used for orthodontic anchorage. Data were collected on 727 mini-implants (miniplates, predrilled titanium miniscrews, and self-drilling stainless steel miniscrews) in 220 patients. The factors related to mini-implant failure were investigated using a Chi-square test for univariate analysis and a generalized estimating equation model for multivariate analysis. The failure rate for miniplates was significantly lower than for miniscrews. All types of mini-implants, especially the self-drilling stainless steel miniscrews, showed decreased stability if the previous implantation had failed. The stability of predrilled titanium miniscrews and self-drilling stainless steel miniscrews were comparable at the first implantation. However, the failure rate of stainless steel miniscrews increased at the second implantation. The univariate analysis showed that the following variables had a significant influence on the failure rates of mini-implants: age of patient, type of mini-implant, site of implantation, and characteristics of the soft tissue around the mini-implants. The generalized estimating equation analysis revealed that mini-implants with miniscrews used in patients younger than 35 years, subjected to orthodontic loading after 30 days and implanted on the alveolar bone ridge, have a significantly higher risk of failure. This study revealed that once the dental surgeon becomes familiar with the procedure, the stability of orthodontic mini-implants depends on the type of mini-implant, age of the patient, implantation site, and the healing time of the mini-implant. Miniplates are a more feasible anchorage system when miniscrews fail repeatedly. Copyright © 2014. Published by Elsevier B.V.

  5. Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: a three-dimensional finite element analysis.

    PubMed

    Liu, Jingyin; Pan, Shaoxia; Dong, Jing; Mo, Zhongjun; Fan, Yubo; Feng, Hailan

    2013-03-01

    The aim of this study was to evaluate strain distribution in peri-implant bone, stress in the abutments and denture stability of mandibular overdentures anchored by different numbers of implants under different loading conditions, through three-dimensional finite element analysis (3D FEA). Four 3D finite element models of mandibular overdentures were established, using between one and four Straumann implants with Locator attachments. Three types of load were applied to the overdenture in each model: 100N vertical and inclined loads on the left first molar and a 100N vertical load on the lower incisors. The biomechanical behaviours of peri-implant bone, implants, abutments and overdentures were recorded. Under vertical load on the lower incisors, the single-implant overdenture rotated over the implant from side to side, and no obvious increase of strain was found in peri-implant bone. Under the same loading conditions, the two-implant-retained overdenture showed more apparent rotation around the fulcrum line passing through the two implants, and the maximum equivalent stress in the abutments was higher than in the other models. In the three-implant-supported overdenture, no strain concentration was found in cortical bone around the middle implant under three loading conditions. Single-implant-retained mandibular overdentures do not show damaging strain concentration in the bone around the only implant and may be a cost-effective treatment option for edentulous patients. A third implant can be placed between the original two when patients rehabilitated by two-implant overdentures report constant and obvious denture rotation around the fulcrum line. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. Influence of Implant Positions and Occlusal Forces on Peri-Implant Bone Stress in Mandibular Two-Implant Overdentures: A 3-Dimensional Finite Element Analysis.

    PubMed

    Alvarez-Arenal, Angel; Gonzalez-Gonzalez, Ignacio; deLlanos-Lanchares, Hector; Brizuela-Velasco, Aritza; Dds, Elena Martin-Fernandez; Ellacuria-Echebarria, Joseba

    2017-12-01

    The aim of this study was to evaluate and compare the bone stress around implants in mandibular 2-implant overdentures depending on the implant location and different loading conditions. Four 3-dimensional finite element models simulating a mandibular 2-implant overdenture and a Locator attachment system were designed. The implants were located at the lateral incisor, canine, second premolar, and crossed-implant levels. A 150 N unilateral and bilateral vertical load of different location was applied, as was 40 N when combined with midline load. Data for von Mises stress were produced numerically, color coded, and compared between the models for peri-implant bone and loading conditions. With unilateral loading, in all 4 models much higher peri-implant bone stress values were recorded on the load side compared with the no-load side, while with bilateral occlusal loading, the stress distribution was similar on both sides. In all models, the posterior unilateral load showed the highest stress, which decreased as the load was applied more mesially. In general, the best biomechanical environment in the peri-implant bone was found in the model with implants at premolar level. In the crossed-implant model, the load side greatly altered the biomechanical environment. Overall, the overdenture with implants at second premolar level should be the chosen design, regardless of where the load is applied. The occlusal loading application site influences the bone stress around the implant. Bilateral occlusal loading distributes the peri-implant bone stress symmetrically, while unilateral loading increases it greatly on the load side, no matter where the implants are located.

  7. Prospective randomized clinical trial of hydrophilic tapered implant placement at maxillary posterior area: 6 weeks and 12 weeks loading

    PubMed Central

    2016-01-01

    PURPOSE Early loading of implant can be determined by excellent primary stability and characteristic of implant surface. The implant system with recently improved surface can have load application 4-6 weeks after installing in maxilla and mandible. This study evaluated the effect of healing period to the stability of hydrophilic tapered-type implant at maxillary posterior area. MATERIALS AND METHODS This study included 30 patients treated by hydrophilic tapered-type implants (total 41 implants at maxilla) and classified by two groups depending on healing period. Group 1 (11 patients, 15 implants) was a control group and the healing period was 12 weeks, and Group 2 (19 patients, 26 implants) was test group and the healing period was 6 weeks. Immediately after implant placement, at the first impression taking, implant stability was measured using Osstell Mentor. The patients also took periapical radiographs after restoration delivery, 12 months after restoration and final followup period. The marginal bone loss around the implants was measured using the periapical radiographs. RESULTS All implants were survived and success rate was 97.56%. The marginal bone loss was less than 1mm after 1 year postoperatively except the one implant. The stabilities of the implants were not correlated with age, healing period until loading, insertion torque (IT), the diameter of fixture and the location of implant. Only the quality of bone in group 2 (6 week) was correlated with the stability of implant. CONCLUSION Healing period of 6 weeks can make the similar clinical prognosis of implants to that of healing period of 12 weeks if bone quality is carefully considered in case of early loading. PMID:27826390

  8. Comparison of Reconstructive Outcomes in Breast Cancer Patients With Preexisting Subpectoral Implants: Implant-Sparing Mastectomy With Delayed Implant Exchange Versus Immediate Tissue Expander Reconstruction.

    PubMed

    Parabkaharan, Sangeetha; Melody, Megan; Trotta, Rose; Lleshi, Amina; Sun, Weihong; Smith, Paul D; Khakpour, Nazanin; Dayicioglu, Deniz

    2016-06-01

    Women who have undergone prior augmentation mammoplasty represent a unique subset of breast cancer patients with several options available for breast reconstruction. We performed a single institution review of surgical outcomes of breast reconstruction performed in patients with breast cancer with prior history of subpectoral breast augmentation. Institutional review board-approved retrospective review was conducted among patients with previously mentioned criteria treated at our institution between 2000 and 2014. Reconstructions were grouped into 2 categories as follows: (1) removal of preexisting subpectoral implant during mastectomy with immediate tissue expander placement and (2) implant-sparing mastectomy followed by delayed exchange to a larger implant. We reviewed demographics, tumor features, and reconstruction outcomes of these groups. Fifty-three patients had preexisting subpectoral implants. Of the 63 breast reconstructions performed, 18 (28.6%) had immediate tissue expander placed and 45 (71.4%) had implant-sparing mastectomy followed by delayed implant exchange. The groups were comparable based on age, body mass index, cancer type, tumor grade, TNM stage at presentation, and hormonal receptor status. No significant difference was noted between tumor margins or subsequent recurrence, mastectomy specimen weight, removed implant volume, volume of implant placed during reconstruction, or time from mastectomy to final implant placement. Rates of complications were significantly higher in the tissue expander group compared to the implant-sparing mastectomy group 7 (38.9%) versus 4 (8.9%) (P = 0.005). Implant-sparing mastectomy with delayed implant exchange in patients with preexisting subpectoral implants is safe and has fewer complications compared to tissue expander placement. There was no difference noted in the final volume of implant placed, time interval for final implant placement, or tumor margins.

  9. Assessment and Evaluation of Quality of Life (OHRQoL) of Patients with Dental Implants Using the Oral Health Impact Profile (OHIP-14) - A Clinical Study.

    PubMed

    Alzarea, Bader K

    2016-04-01

    Peri-implant tissue health is a requisite for success of dental implant therapy. Plaque accumulation leads to initiation of gingivitis around natural teeth and peri-implantitis around dental implants. Peri-implantitis around dental implants may result in implant placement failure. For obtaining long-term success, timely assessment of dental implant site is mandatory. To assess and evaluate Quality of Life (OHRQoL) of individuals with dental implants using the Oral Health Impact Profile (OHIP-14). Total 92 patients were evaluated for assessment of the health of peri-implant tissues by recording, Plaque Index (PI), Probing Pocket Depth (PD), Bleeding On Probing (BOP) and Probing Attachment Level (PAL) as compared to contra-lateral natural teeth (control). In the same patients Quality of Life Assessment was done by utilizing Oral Health Impact Profile Index (OHIP-14). The mean plaque index around natural teeth was more compared to implants and it was statistically significant. Other three dimensions mean bleeding on probing; mean probing attachment level and mean pocket depth around both natural teeth and implant surfaces was found to be not statistically significant. OHIP-14 revealed that patients with dental implants were satisfied with their Oral Health-Related Quality of Life (OHRQoL). Similar inflammatory conditions are present around both natural teeth and implant prostheses as suggested by results of mean plaque index, mean bleeding on probing, mean pocket depth and mean probing attachment level, hence reinforcing the periodontal health maintenance both prior to and after incorporation of dental implants. Influence of implant prostheses on patient's oral health related quality of life (as depicted by OHIP-14) and patients' perceptions and expectations may guide the clinician in providing the best implant services.

  10. Retrospective analysis of survival rates and marginal bone loss on short implants in the mandible.

    PubMed

    Draenert, Florian G; Sagheb, Keyvan; Baumgardt, Katharina; Kämmerer, Peer W

    2012-09-01

    Short implants have become an interesting alternative to bone augmentation in dental implantology. Design of shorter implants and longer surveillance times are a current research issue. The goal of this study was to show the survival rates of short implants below 9 mm in the partly edentulous mandibular premolar and molar regions with fixed prosthetics. Marginal vertical and 2D bone loss was evaluated additionally. Different implant designs are orientationally evaluated. A total of 247 dental implants with fixed prosthetics (crowns and bridges) in the premolar and molar region of the mandible were evaluated; 47 implants were 9 mm or shorter. Patient data were evaluated to acquire implant survival rates, implant diameter, gender and age. Panoramic X-rays were analysed for marginal bone loss. Average surveillance time was 1327 days. Cumulative survival rate (CSR) of short implants was 98% (1 implants lost) compared to 94% in the longer implants group without significance. Thirty-five of the short implants were Astratech (0 losses) and 12 were Camlog Screw Line Promote Plus (1 loss). Early vertical and two-dimensional marginal bone loss was not significantly different in short and regular length implant group with an average of 0.6 mm and 0.7 mm(2) in short implants over the observation period. Within the limitations of this study, we conclude that short implants with a length of 9 mm or less have equal survival rates compared with longer implants over the observation period of 1-3 years. © 2011 John Wiley & Sons A/S.

  11. Oral Health-Related Quality of Life in Edentulous Patients with Two- vs Four-Locator-Retained Mandibular Overdentures: A Prospective, Randomized, Crossover Study.

    PubMed

    Karbach, Julia; Hartmann, Sinsa; Jahn-Eimermacher, Antje; Wagner, Wilfried

    2015-01-01

    To compare the oral health-related quality of life (OHRQoL) in a prospective, randomized crossover trial in patients with mandibular overdentures retained with two or four locators. In 30 patients with edentulous mandibles, four implants (ICX-plus implants [Medentis Medical]) were placed in the intraforaminal area. Eight weeks after transgingival healing, patients were randomly assigned to have two or four implants incorporated in the prosthesis. After 3 months, the retention concepts were switched. The patients with a two-implant-supported overdenture had four implants incorporated, whereas patients with a four-implant-supported overdenture had two retention locators taken out. After 3 more months, all four implants were retained in the implant-supported overdenture in every patient. To measure OHRQoL of the patients, the Oral Health Impact Profile 14, German version (OHIP-14 G), was used. A considerable increase in OHRQoL could be seen in all patients after the prosthesis was placed on the implants. Also, a statistically significant difference of OHRQoL could be seen in the OHIP-14 G scores between two-implant and four-implant overdentures. Patients had a higher OHRQoL after incorporation of four implants in the overdenture compared with only two implants. Patients with implant-retained overdentures had better OHRQoL compared with those with conventional dentures. The number of incorporated implants in the locator-retained overdenture also influenced the increase in OHRQoL, with four implants having a statistically significant advantage over two implants.

  12. Biomechanical interactions of endodontically treated tooth implant-supported prosthesis under fatigue test with acoustic emission monitoring.

    PubMed

    Huang, Shao-Fu; Chen, Wan-Rung; Lin, Chun-Li

    2016-02-24

    This study investigated the biomechanical interactions in endodontically treated tooth implant-supported prosthesis (TISP) with implant system variations under dynamic cyclic loads monitored using the acoustic emission (AE) technique. Macrostructure implants using a taper integrated screw-in (TIS; 2-piece implant) and a retaining-screw (RS; 3-piece implant) connected to an abutment were used for this investigation and their corresponding mechanical resistances in conformity with the ISO 14801 standard were evaluated. The endodontically treated TISP samples were constructed containing TIS and RS implants splinted to the second premolar with fatigue tests performed by applying occlusal force onto the premolar simulating the bending moment effect. The numbers of accumulated AE signals in the fatigue tests and failure modes for the sample were recorded to evaluate the mechanical resistance. The maximum load in the static test for RS (3-piece) implant (797N) was significantly higher than that for the TIS (2-piece) implant (559N). Large deformations were found at abutment screws in both RS and TIS implants. Although the numbers of accumulated AE signals for the TIS implant (72511) were higher than those for the RS implant (437), statistical non-significant differences were found between TIS and RS implants. No obvious damage was noted in endodontically treated TISP samples using RS implants but two of the corresponding TIS implants fractured in the abutment screws. Splints with RS (3-piece) implant prosthesis produce better mechanical responses than the TIS (2-piece) implant when connected to an endodontically treated tooth restored with a post core and crown.

  13. Micromotion-induced strain fields influence early stages of repair at bone-implant interfaces

    PubMed Central

    Wazen, Rima M.; Currey, Jennifer A.; Guo, Hongqiang; Brunski, John B.; Helms, Jill A.; Nanci, Antonio

    2013-01-01

    Implant loading can create micromotion at the bone-implant interface. The interfacial strain associated with implant micromotion could contribute to regulating the tissue healing response. Excessive micromotion can lead to fibrous encapsulation and implant loosening. Our objective was to characterize the influence of interfacial strain on bone regeneration around implants in mouse tibiae. A micromotion system was used to create strain under conditions of (1) no initial contact between implant and bone, and (2) a direct bone-implant contact. Pin- and screw-shaped implants were subjected to displacements of 150 μm or 300 μm, 60 cycles/day, for 7 days. Pin-shaped implants placed in 5 animals were subjected to 3 sessions of 150 μm displacement per day, with 60 cycles per session. Control implants in both types of interfaces were stabilized throughout the healing period. Experimental strain analyses, microtomography, image-based displacement mapping, and finite element simulations were used to characterize interfacial strain fields. Calcified tissue sections were prepared and stained with Goldner to evaluate tissue reaction in higher and lower strain regions. In stable implants, bone formation occurred consistently around the implants. In implants subjected to micromotion, bone regeneration was disrupted in areas of high strain concentrations (e.g. > 30%), whereas lower strain values were permissive of bone formation. Increasing implant displacement or number of cycles per day also changed the strain distribution and disturbed bone healing. These results indicate that not only implant micromotion but also the associated interfacial strain field contributes to regulating the interfacial mechanobiology at healing bone-implant interfaces. PMID:23337705

  14. Retrospective analysis of dental implants placed and restored by advanced prosthodontic residents.

    PubMed

    Barias, Pamela A; Lee, Damian J; Yuan, Judy Chia-Chun; Sukotjo, Cortino; Campbell, Stephen D; Knoernschild, Kent L

    2013-02-01

    The purposes of this retrospective clinical review were to: (1) describe the demographics of implant patients, types of implant treatment and implant-supported prostheses in an Advanced Education in Prosthodontic Program, (2) evaluate the survival rate of dental implants placed by prosthodontic residents from 2006 to 2008, and (3) analyze the relationship between resident year of training and implant survival rate. All patients who received dental implants placed by prosthodontic residents from January 2006 to October of 2008 in the Advanced Prosthodontic Program at the University of Illinois at Chicago College of Dentistry were selected for this study. Age, gender, implant diameter, length, implant locations, surgical and restorative detail, and year of prosthodontic residency training were collected and analyzed. Life-table and Kaplan-Meier survival analyses were performed based on implants overall, locations, year of training, and use of a computer-generated surgical guide. A Logrank statistic was performed between implant survival and year of prosthodontic residency training, location, and use of computer-generated surgical guide (α= 0.05). Three hundred and six implants were placed, and of these, seven failed. Life-table and Kaplan-Meier analyses computed a cumulative survival rate (CSR) of 97% for overall implants and implants placed with a computer-generated surgical guide. No statistical difference was found in implant survival rates as a function of year of training (P= 0.85). Dental implants placed by prosthodontic residents had a CSR comparable to previously published studies by other specialties. The year of prosthodontic residency training and implant failure rate did not have any significant relationship. © 2012 by the American College of Prosthodontists.

  15. A Ballistics Examination of Firearm Injuries Involving Breast Implants.

    PubMed

    Pannucci, Christopher J; Cyr, Adam J; Moores, Neal G; Young, Jason B; Szegedi, Martin

    2018-03-01

    This ballistics study examines whether saline breast implants can decrease tissue penetration in firearm injuries. We hypothesize that the fluid column within a saline breast implant can alter bullet velocity and/or bullet pattern of mushrooming. The two experimental groups included saline implants with 7.4 cm projection and a no implant group. The experimental design allowed the bullet to pass-through an implant and into ballistics gel (n = 10) or into ballistics gel without passage through an implant (n = 11). Shots that passed through an implant had 20.6% decreased penetration distance when compared to shots that did not pass-through an implant; this difference was statistically significant (31.9 cm vs. 40.2 cm, p < 0.001). Implant group bullets mushroomed prior to gel entry, but the no implant group mushroomed within the gel. Bullet passage through a saline breast implant results in direct bullet velocity reduction and earlier bullet mushrooming; this causes significantly decreased ballistics gel penetration. © 2017 American Academy of Forensic Sciences.

  16. Why do dental implants fail? Part I.

    PubMed

    el Askary, A S; Meffert, R M; Griffin, T

    1999-01-01

    Many factors are attributed to failure of the dental implant, either directly or indirectly. The focus of this article is to define the causation of dental implant failure, as well as to present an evaluation of the implant literature regarding etiology, classification, management, and treatment of implant failures. This article will highlight the initial signs of implant failure with a view of some clinical cases in terms of classification and degrees of implant failure. Finally, a dental implant failure checklist is formulated to guide the practitioner in defining the cause of implant failure, be it infective or noninfective, and to establish percentages and frequency of occurrence. The checklist applies to all implant systems and will help to determine the factors responsible for causation and the repair procedures, whether they are at the surgical or restorative phases. The definition of implant failure is set forth in terms of ailing, failing, failed, and surviving implants, and the appropriate treatments and dispositions are outlined.

  17. Benefits and Limitations of Macrotextured Breast Implants and Consensus Recommendations for Optimizing Their Effectiveness.

    PubMed

    Maxwell, G Patrick; Scheflan, Michael; Spear, Scott; Nava, Maurizio B; Hedén, Per

    2014-08-01

    Implant texture is an important factor influencing implant selection for breast augmentation. Natrelle Biocell implants are characterized by macrotextured shell surfaces containing irregularly arranged concavities with large open-pore diameters and depths. These properties facilitate adhesion of the implant to the surrounding tissue, thereby promoting implant immobilization. Relative to implants with other surfaces, macrotextured implants offer low rates of capsular contracture; low rates of malposition, rotation, and rippling; and high rates of patient satisfaction. However, macrotextured implants are associated with a slightly higher risk of double capsule and late seroma. The surgeon can minimize these risks with straightforward techniques that encourage tissue adhesion. This report presents experience-based recommendations to optimize the effectiveness of Biocell anatomic implants. The authors discuss the application of best practices to all aspects of the breast implantation process, from implant selection and surgical planning to operative technique and postoperative management. LEVEL OF EVIDENCE 3. © 2014 The American Society for Aesthetic Plastic Surgery, Inc.

  18. Clinical and radiological investigations of mandibular overdentures supported by conventional or mini-dental implants: A 2-year prospective follow-up study.

    PubMed

    Temizel, Sonay; Heinemann, Friedhelm; Dirk, Cornelius; Bourauel, Christoph; Hasan, Istabrak

    2017-02-01

    Conventional dental implants are not applicable in the mandibular interforaminal region if bone volume is limited. Mini-dental implants offer an alternative means of supporting mandibular overdentures in a narrow residual ridge, without additional surgery. The purpose of this nonrandomized clinical trial was to compare the ability of mini-dental implants with that of conventional dental implants in supporting mandibular overdentures during a 2-year clinical follow-up. Bone quality, bone resorption, implant stability, and oral health were assessed radiographically. A total of 32 participants with edentulism were included. Twenty-two participants (99 implants) received 4 to 5 mini-dental implants (diameter: 1.8-2.4 mm; length: 13-15 mm, study group), and 10 participants (35 implants) received 2 to 4 conventional dental implants (diameter: 3.3-3.7 mm; length: 11-13 mm, control group). The selection of the participants in the study or control group was based on the available bone volume in the mandible. The selection was not randomized. The density of cortical bone thickness was measured in Hounsfield units (HU) from computed tomography data, and patients were followed for 2 years. The participants were examined 3, 6, 12, and 24 months after surgery. Primary stability immediately after the insertion of dental implants (Periotest), secondary stability 6 months after implantation, modified plaque, bleeding on probing indices, and probing depth were measured and analyzed statistically (α=.05). The mean HU value 6 months after implantation in the participants who received mini-dental implants was significantly (P=.035) higher (1250 HU) than that in the participants who received conventional dental implants (1100 HU). The probing depths around the conventional dental implants (1.6 and 1.8 mm, respectively) were significantly higher than those around the mini-dental implants (1.3 and 1.2 mm, respectively) 12 and 24 months after surgery, respectively (P<.001). The mean primary and secondary stability values for conventional dental implants were -4.0 and -4.9, respectively. The primary and secondary stability values for the mini-dental implants were -0.3 and -1.4, respectively. The Periotest values of the primary (measured immediately after implant insertion) and secondary implant stabilities (measured 6 months after implant insertion) were significantly higher for the conventional dental implants than for the mini-dental implants (P<.001). Based on this 2-year clinical trial, patients receiving mini-dental implants had clinical outcomes similar to those of patients receiving conventional dental implants to support overdenture prostheses. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Bacterial colonization of the implant-abutment interface of conical connection with an internal octagon: an in vitro study using real-time PCR.

    PubMed

    Baj, A; Beltramini, G A; Bolzoni, A; Cura, F; Palmieri, A; Scarano, A; Ottria, L; Giannì, A B

    2017-01-01

    Bacterial leakage at the implant-abutment connection of a two-piece implant system is considered the main cause of peri-implantitis. Prevention of bacterial leakage at the implant-abutment connection is mandatory for reducing inflammation process around implant neck and achieving bone stability. Micro-cavities at implant-abutment connection level can favour bacterial leakage, even in modern two-piece implant systems. The conical connection with an internal octagon (CCIO) is considered to be more stable mechanically and allows a more tight link between implant and abutment. As P. gingivalis and T. forsythia penetration might have clinical relevance, it was the purpose of this investigation to evaluate molecular leakage of these two bacteria in a new two-implant system with an internal conical implant-abutment connection with internal octagon (Shiner XT, FMD Falappa Medical Devices S.p.A. Rome, Italy). To verify the ability of the implant in protecting the internal space from the external environment, the passage of genetically modified Escherichia c oli across implant-abutment interface was evaluated. Four Shiner XT implants (FMD, Falappa Medical Devices®, Rome, Italy) were immerged in a bacterial culture for 24 h and bacteria amount was measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 6% for P. gingivalis and 5% for T. forsythia. Other comparable studies about the tightness of the tested implant system reported similar results. The gap size at the implant-abutment connection of CCIOs was measured by other authors discovering a gap size of 1–2μm of the AstraTech system and of 4μm for the Ankylos system. Bacterial leakage along implant-abutment connection of cylindrical and tapered implants, Shiner XT, (FMD Falappa Medical Devices S.p.A. Rome, Italy) showed better results compared to other implants. Additional studies are needed to explore the relationship in terms of microbiota of the CCIO. In addition, the dynamics of internal colonization needs to be thoroughly documented in longitudinal in vivo studies.

  20. [Bilateral cochlear implants in children: acquisition of binaural hearing].

    PubMed

    Ramos-Macías, Angel; Deive-Maggiolo, Leopoldo; Artiles-Cabrera, Ovidio; González-Aguado, Rocío; Borkoski-Barreiro, Silvia A; Masgoret-Palau, Elizabeth; Falcón-González, Juan C; Bueno-Yanes, Jorge

    2013-01-01

    Several studies have indicated the benefit of bilateral cochlear implants in the acquisition of binaural hearing and bilateralism. In children with cochlear implants, is it possible to achieve binaurality after a second implant? When is the ideal time to implant them? The objective of this study was to analyse the binaural effect in children with bilateral implants and the differences between subjects with simultaneous and sequential implants with both short and long intervals. There were 90 patients between 1 and 2 years of age (the first surgery), implanted between 2000 and 2008. Of these, 25 were unilateral users and 65 bilateral; 17 patients had received simultaneous implants, 29 had sequential implants before 12 months after the first one (short interimplant period) and 19 after 12 months (long period). All of them were tested for silent and noisy verbal perception and a tonal threshold audiometry was performed. The silent perception test showed that the simultaneous and short period sequential implant patients (mean: 84.67%) versus unilateral and long period sequential implants (mean: 79.66%), had a statistically-significant difference (P=0,23). Likewise, the noisy perception test showed a difference with statistical significance (P=0,22) comparing the simultaneous implanted and short period sequential implants (mean, 77.17%) versus unilateral implanted and long period sequential ones (mean: 69.32%). The simultaneous and sequential short period implants acquired the advantages of binaural hearing. Copyright © 2012 Elsevier España, S.L. All rights reserved.

  1. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla.

    PubMed

    Desai, Shrikar R; Singh, Rika; Karthikeyan, I

    2013-09-01

    The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm-diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results.

  2. Multiscale Analyses of the Bone-implant Interface

    PubMed Central

    Cha, J.Y.; Pereira, M.D.; Smith, A.A.; Houschyar, K.S.; Yin, X.; Mouraret, S.; Brunski, J.B.

    2015-01-01

    Implants placed with high insertion torque (IT) typically exhibit primary stability, which enables early loading. Whether high IT has a negative impact on peri-implant bone health, however, remains to be determined. The purpose of this study was to ascertain how peri-implant bone responds to strains and stresses created when implants are placed with low and high IT. Titanium micro-implants were inserted into murine femurs with low and high IT using torque values that were scaled to approximate those used to place clinically sized implants. Torque created in peri-implant tissues a distribution and magnitude of strains, which were calculated through finite element modeling. Stiffness tests quantified primary and secondary implant stability. At multiple time points, molecular, cellular, and histomorphometric analyses were performed to quantitatively determine the effect of high and low strains on apoptosis, mineralization, resorption, and collagen matrix deposition in peri-implant bone. Preparation of an osteotomy results in a narrow zone of dead and dying osteocytes in peri-implant bone that is not significantly enlarged in response to implants placed with low IT. Placing implants with high IT more than doubles this zone of dead and dying osteocytes. As a result, peri-implant bone develops micro-fractures, bone resorption is increased, and bone formation is decreased. Using high IT to place an implant creates high interfacial stress and strain that are associated with damage to peri-implant bone and therefore should be avoided to best preserve the viability of this tissue. PMID:25628271

  3. One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study.

    PubMed

    Siddiqi, A; Duncan, W J; De Silva, R K; Zafar, S

    2016-01-01

    Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, placed in the jaws and femurs of domestic sheep. Ten New Zealand mixed breed sheep were used. A One-piece prototype Ti (control) and one Zr (test) implant were placed in the mandible, and one of each implant (Ti and Zr) was placed into the femoral epicondyle of each animal. The femur implants were submerged and unloaded; the mandibular implants were placed using a one-stage transgingival protocol and were nonsubmerged. After a healing period of 12 weeks, %BIC was measured. The overall survival rate for mandibular and femur implants combined was 87.5%. %BIC was higher for Zr implants versus Ti implants in the femur (85.5%, versus 78.9%) ( p = 0.002). Zirconia implants in the mandible showed comparable %BIC to titanium implants (72.2%, versus 60.3%) ( p = 0.087). High failure rate of both Zr and Ti one-piece implants in the jaw could be attributed to the one-piece design and surface characteristics of the implant that could have influenced osseointegration. Further clinical trials are recommended to evaluate the performance of zirconia implants under loading conditions.

  4. Three-Dimensional Finite Element Analysis on Stress Distribution of Internal Implant-Abutment Engagement Features.

    PubMed

    Cho, Sung-Yong; Huh, Yun-Hyuk; Park, Chan-Jin; Cho, Lee-Ra

    To investigate the stress distribution in an implant-abutment complex with a preloaded abutment screw by comparing implant-abutment engagement features using three-dimensional finite element analysis (FEA). For FEA modeling, two implants-one with a single (S) engagement system and the other with a double (D) engagement system-were placed in the human mandibular molar region. Two types of abutments (hexagonal, conical) were connected to the implants. Different implant models (a single implant, two parallel implants, and mesial and tilted distal implants with 1-mm bone loss) were assumed. A static axial force and a 45-degree oblique force of 200 N were applied as the sum of vectors to the top of the prosthetic occlusal surface with a preload of 30 Ncm in the abutment screw. The von Mises stresses at the implant-abutment and abutment-screw interfaces were measured. In the single implant model, the S-conical abutment type exhibited broader stress distribution than the S-hexagonal abutment. In the double engagement system, the stress concentration was high in the lower contact area of the implant-abutment engagement. In the tilted implant model, the stress concentration point was different from that in the parallel implant model because of the difference in the bone level. The double engagement system demonstrated a high stress concentration at the lower contact area of the implant-abutment interface. To decrease the stress concentration, the type of engagement features of the implant-abutment connection should be carefully considered.

  5. Cone-morse implant connection system significantly reduces bacterial leakage between implant and abutment: an in vitro study.

    PubMed

    Baj, A; Bolzoni, A; Russillo, A; Lauritano, D; Palmieri, A; Cura, F; Silvestre, F J; Giannì, A B

    2017-01-01

    Osseointegrated implants are very popular dental treatments today in the world. In osseointegrated implants, the occlusal forces are transmitted from prosthesis through an abutment to a dental implant. The abutment is connected to the implant by mean of a screw. A screw is the most used mean for connecting an implant to an abutment. Frequently the screws break and are lost. There is an alternative to screw retained abutment systems: the cone-morse connection (CMC). The CMC, thanks to the absence of the abutment screw, guarantees no micro-gaps, no micro-movements, and a reduction of bacterial leakage between implant and abutment. As P. gingivalis and T. forsythia penetration might have clinical relevance, it was the purpose of this investigation to evaluate molecular leakage of these two bacteria in a new CMC implants systems (Leone Spa®, Florence, Italy). To identify the capability of the implant to protect the internal space from the external environment, the passage of genetically modified Escherichia coli across implant-abutment interface was evaluated. Four cone-morse Leone implants (Leone® Spa, Florence, Italy) were immerged in a bacterial culture for 24 h and bacteria amount was then measured inside implant-abutment interface with Real-time PCR. Bacteria were detected inside all studied implants, with a median percentage of 3% for P. gingivalis and 4% for T. forsythia. Cone-morse connection implant system has very low bacterial leakage percentage and is similar to one-piece implants.

  6. Effect of osteoporosis on fixation of osseointegrated implants in rats.

    PubMed

    Li, Yunfeng; He, Sheng; Hua, Yunwei; Hu, Jing

    2017-11-01

    The effect of osteoporosis on implant osseointegration has been widely investigated, whereas osteoporosis may also newly occur in patient with previously osseointegrated implant. This study was designed to investigate the effect of osteoporosis on implant fixation in rats after successful osseointegration had been obtained. Seventy female Sprague-Dawley rats were included, and each animal received two titanium implants in the distal metaphysis of femur bilaterally. Eight weeks later, ten rats were sacrificed to confirm the establishment of implant osseointegration. All left rats were randomly subjected to bilateral ovariectomy (OVX) or sham operation. Three, six, and twelve weeks later, implant osseointegration, peri-implant bone tissue, and biomechanical properties of implant were analyzed. Right femurs with implants were used for micro-CT and histological analysis, and left femurs with implants were used for biomechanical test. Micro-CT, histology, and biomechanical test confirmed the destructive effect of OVX on previously osseointegrated implant in rats; when compared to sham-operated rats, peri-implant bone volume, trabecular architecture, bone-to-implant contact ratio, as well as biomechanical parameters decreased progressively within 12 weeks. Results also indicated that the effect of OVX on undisturbed bone (proximal tibiae) was much stronger than that on peri-implant bone. Osteoporosis produced a progressive negative effect on previously osseointegrated implant in distal femora of rats during 12 weeks. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2426-2432, 2017. © 2016 Wiley Periodicals, Inc.

  7. One-Piece Zirconia Ceramic versus Titanium Implants in the Jaw and Femur of a Sheep Model: A Pilot Study

    PubMed Central

    De Silva, R. K.; Zafar, S.

    2016-01-01

    Reports have documented titanium (Ti) hypersensitivity after dental implant treatment. Alternative materials have been suggested including zirconia (Zr) ceramics, which have shown predictable osseointegration in animal studies and appear free of immune responses. The aim of the research was to investigate the bone-to-implant contact (BIC) of one-piece Zr, compared with one-piece Ti implants, placed in the jaws and femurs of domestic sheep. Ten New Zealand mixed breed sheep were used. A One-piece prototype Ti (control) and one Zr (test) implant were placed in the mandible, and one of each implant (Ti and Zr) was placed into the femoral epicondyle of each animal. The femur implants were submerged and unloaded; the mandibular implants were placed using a one-stage transgingival protocol and were nonsubmerged. After a healing period of 12 weeks, %BIC was measured. The overall survival rate for mandibular and femur implants combined was 87.5%. %BIC was higher for Zr implants versus Ti implants in the femur (85.5%, versus 78.9%) (p = 0.002). Zirconia implants in the mandible showed comparable %BIC to titanium implants (72.2%, versus 60.3%) (p = 0.087). High failure rate of both Zr and Ti one-piece implants in the jaw could be attributed to the one-piece design and surface characteristics of the implant that could have influenced osseointegration. Further clinical trials are recommended to evaluate the performance of zirconia implants under loading conditions. PMID:28058261

  8. Risk factors for implant failure: a retrospective study in an educational institution using GEE analyses.

    PubMed

    Borba, Marcelo; Deluiz, Daniel; Lourenço, Eduardo José Veras; Oliveira, Luciano; Tannure, Patrícia Nivoloni

    2017-08-21

    This study aimed to evaluate dental implant outcomes and to identify risk factors associated with implant failure over 12 years via dental records of patients attending an educational institution. Dental records of 202 patients receiving 774 dental implants from 2002 to 2014 were analyzed by adopting a more reliable statistical method to evaluate risk factors with patients as the unit [generalized estimating equation (GEE)]. Information regarding patient age at implantation, sex, use of tobacco, and history of systemic diseases was collected. Information about implant location in the arch region and implant length, diameter, and placement in a grafted area was evaluated after 2 years under load. Systemic and local risk factors for early and late implant failure were studied. A total of 18 patients experienced 25 implant failures, resulting in an overall survival rate of 96.8% (2.84% and 0.38% early and late implant failures, respectively). The patient-based survival rate was 91.8%. GEE univariate and multivariate analyses revealed that a significant risk factor for implant failure was the maxillary implant (p = 0.006 and p = 0.014, respectively). Bone grafting appeared to be a risk factor for implant failure (p = 0.054). According to GEE analyses, maxillary implants had significantly worse outcomes in this population and were considered to be a risk factor for implant failure. Our results suggested that implants placed in a bone augmentation area had a tendency to fail.

  9. Peri-implant plastic surgery techniques to hard and soft tissue augmentation in implant rehabilitation

    PubMed Central

    Baltacioğlu, Esra; Korkmaz, Yavuz Tolga; Korkmaz, Fatih Mehmet; Aydin, Güven; Sukuroglu, Erkan

    2017-01-01

    This report presents the clinical results of peri-implant plastic surgical approaches for hard and soft tissues before and during the implant placement in a patient with vertical ridge deformation and a shallow vestibule sulcus, and the subsequently performed prosthetic rehabilitation. The surgical approaches used in this case reduced the crown-height space and crown-to-implant ratio and ensured that the implants were placed in their ideal positions, and peri-implant tissue health was maintained. In conclusion, developments in the peri-implant plastic surgery enable the successful augmentation of hard and soft tissue defects and provide the implant-supported fixed prosthetic rehabilitation. PMID:29386805

  10. The glass spherical hollow orbital implant: a prospective study.

    PubMed

    Stephen, B E

    1999-06-01

    Various types of orbital implants are in use in the rehabilitation of anophthalmic patients. The latest is the expensive hydroxyapatite implant. The study objective was to evaluate the effectiveness of low cost glass spherical hollow implants, as primary and secondary implants. St Michaels and Frazer Private Hospitals, Colombo. 65 patients had glass sphere orbital implants between 1987 and 1995; 51 primary (evisceration 46, enucleation 5) and 14 secondary (evisceration 2, enucleation 12). At 9 to 12 months follow up, patients were evaluated for mobility of implant, prosthesis mobility, lid sulcus deformity, cosmetic results and complications. Primary glass spherical hollow implants provide excellent mobility of the implant (92%), cosmesis (88%), prosthesis mobility (67%), with a low rate of complications (9.5%). Results of primary implant was superior to that of secondary (p < 0.001). Excellent results were obtained with spherical glass spheres as primary implants following evisceration.

  11. Histologic analysis of a failing three-part dental implant: a human case report.

    PubMed

    Landi, Luca; Manicone, Paolo Francesco; Piccinelli, Stefano; Raia, Roberto

    2005-12-01

    Two failing implants were removed for prosthetic reasons from the maxilla of a 60-year-old woman. The implants were clinically immobile but presented clear signs of peri-implant mucositis and bone destruction. One of the two implants was harvested together with the surrounding bone and analyzed histologically. The implant was threaded and consisted of three distinct components screwed together in a telescopic fashion. Histologically, bone loss reached the fourth thread, while apical to the fourth thread, osseointegration between the host bone and the implant surface was recognizable. The implant parts were not completely seated into each other, and the resulting gap was colonized by host bone. Newly formed alveolar bone penetrated deep into the implant body cavity and appeared similar in nature to the alveolar bone surrounding the implant. Histologic findings are discussed in reference to the ability of such an implant to withstand biomechanical loading over time.

  12. Analysis of the influence of the macro- and microstructure of dental zirconium implants on osseointegration: a minipig study.

    PubMed

    Mueller, Cornelia Katharina; Solcher, Philipp; Peisker, Andrè; Mtsariashvilli, Maia; Schlegel, Karl Andreas; Hildebrand, Gerhard; Rost, Juergen; Liefeith, Klaus; Chen, Jiang; Schultze-Mosgau, Stefan

    2013-07-01

    It was the aim of this study to analyze the influence of implant design and surface topography on the osseointegration of dental zirconium implants. Six different implant designs were tested in the study. Nine or 10 test implants were inserted in the frontal skull in each of 10 miniature pigs. Biopsies were harvested after 2 and 4 months and subjected to microradiography. No significant differences between titanium and zirconium were found regarding the microradiographically detected bone-implant contact (BIC). Cylindric zirconium implants showed a higher BIC at the 2-month follow-up than conic zirconium implants. Among zirconium implants, those with an intermediate Ra value showed a significantly higher BIC compared with low and high Ra implants 4 months after surgery. Regarding osseointegration, titanium and zirconium showed equal properties. Cylindric implant design and intermediate surface roughness seemed to enhance osseointegration. Copyright © 2013 Elsevier Inc. All rights reserved.

  13. EAO Supplement Working Group 4 - EAO CC 2015 Short implants versus sinus lifting with longer implants to restore the posterior maxilla: a systematic review.

    PubMed

    Thoma, D S; Zeltner, M; Hüsler, J; Hämmerle, C H F; Jung, R E

    2015-09-01

    To compare short implants in the posterior maxilla to longer implants placed after or simultaneously with sinus floor elevation procedures. The focused question was as follows: Are short implants superior to longer implants in the augmented sinus in terms of survival and complication rates of implants and reconstructions, patient-reported outcome measures (PROMs) and costs? A MEDLINE search (1990-2014) was performed for randomized controlled clinical studies comparing short implants (≤8 mm) to longer implants (>8 mm) in augmented sinus. The search was complimented by an additional hand search of the selected papers and reviews published between 2011 and 2014. Eligible studies were selected based on the inclusion criteria, and quality assessments were conducted. Descriptive statistics were applied for a number of outcome measures. Survival rates of dental implants were pooled simply in case of comparable studies. Eight randomized controlled clinical trials (RCTs) comparing short implants versus longer implants in the augmented sinus derived from an initial search count of 851 titles were selected and data extracted. In general, all studies were well conducted with a low risk of bias for the majority of the analyzed parameters. Based on the pooled analyses of longer follow-ups (5 studies, 16-18 months), the survival rate of longer implants amounted to 99.5% (95% CI: 97.6-99.98%) and for shorter implants to 99.0% (95% CI: 96.4-99.8%). For shorter follow-ups (3 studies, 8-9 months), the survival rates of longer implants are 100% (95% CI: 97.1-100%) and for shorter implants 98.2% (95% CI: 93.9-99.7%). Complications were predominantly of biological origin, mainly occurred intraoperatively as membrane perforations, and were almost three times as higher for longer implant in the augmented sinus compared to shorter implants. PROMs, morbidity, surgical time and costs were generally in favor of shorter dental implants. All studies were performed by surgeons in specialized clinical settings. The outcomes of the survey analyses demonstrated predictably high implant survival rates for short implants and longer implants placed in augmented sinus and their respective reconstructions. Given the higher number of biological complications, increased morbidity, costs and surgical time of longer dental implants in the augmented sinus, shorter dental implants may represent the preferred treatment alternative. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Incentivizing Monitoring and Compliance in Trophy Hunting

    PubMed Central

    BUNNEFELD, NILS; EDWARDS, CHARLES T T; ATICKEM, ANAGAW; HAILU, FETENE; MILNER-GULLAND, E J

    2014-01-01

    Conservation scientists are increasingly focusing on the drivers of human behavior and on the implications of various sources of uncertainty for management decision making. Trophy hunting has been suggested as a conservation tool because it gives economic value to wildlife, but recent examples show that overharvesting is a substantial problem and that data limitations are rife. We use a case study of trophy hunting of an endangered antelope, the mountain nyala (Tragelaphus buxtoni), to explore how uncertainties generated by population monitoring and poaching interact with decision making by 2 key stakeholders: the safari companies and the government. We built a management strategy evaluation model that encompasses the population dynamics of mountain nyala, a monitoring model, and a company decision making model. We investigated scenarios of investment into antipoaching and monitoring by governments and safari companies. Harvest strategy was robust to the uncertainty in the population estimates obtained from monitoring, but poaching had a much stronger effect on quota and sustainability. Hence, reducing poaching is in the interests of companies wishing to increase the profitability of their enterprises, for example by engaging community members as game scouts. There is a threshold level of uncertainty in the population estimates beyond which the year-to-year variation in the trophy quota prevented planning by the safari companies. This suggests a role for government in ensuring that a baseline level of population monitoring is carried out such that this level is not exceeded. Our results illustrate the importance of considering the incentives of multiple stakeholders when designing frameworks for resource use and when designing management frameworks to address the particular sources of uncertainty that affect system sustainability most heavily. Incentivando el Monitoreo y el Cumplimiento en la Caza de Trofeos Resumen Científicos conservacionistas cada vez se enfocan más en los conductores del comportamiento humano y en las implicaciones de varias fuentes de incertidumbre en la toma de decisiones de manejo. La cacería de trofeos ha sido sugerida como una herramienta de conservación porque le otorga valor económico a la vida silvestre, pero ejemplos recientes muestran que la sobrecolecta es un problema sustancial y que las limitaciones de datos son abundantes. Usamos el estudio de caso de la cacería de trofeos de un antílope en peligro, el nyala de las montañas (Tragelaphus buxtoni), para explorar como las incertidumbres generadas por el monitoreo de poblaciones y el tráfico de especies interactúan con la toma de decisiones de 2 actores clave: las compañías de safari y el gobierno. Construimos un modelo de evaluación de estrategia de manejo que incluye la dinámica poblacional del nyala de las montañas, un modelo de monitoreo y un modelo de toma de decisiones de una compañía. Investigamos escenarios de inversión en el combate del tráfico de especies y el monitoreo por el gobierno y las compañías de safari. La estrategia de colecta fue robusta hacia la incertidumbre en los estimados de población obtenidos del monitoreo, pero el tráfico de especies tuvo un efecto más fuerte sobre la cuota y la sustentabilidad; por esto, reducir el tráfico de especies está dentro de los intereses de compañías que desean incrementar la rentabilidad de las empresas, por ejemplo al hacer participar a los miembros de la comunidad como guías de caza. Hay un nivel umbral de incertidumbre en los estimados de población más allá del cual la variación anual en la cuota de trofeos previene la planeación por parte de las compañías de safari. Esto sugiere un papel para el gobierno asegurando que un nivel base de monitoreo de población se lleve a cabo para que este nivel no sea excedido. Nuestros resultados ilustran la importancia de considerar los incentivos de partes interesadas múltiples al designar marcos de trabajo para el uso de recursos y que al designar marcos de trabajo de manejo dirigirse a las fuentes particulares de incertidumbre que afecten más al sistema de sustentabilidad. PMID:24001054

  15. Calfplasty.

    PubMed

    Felício, Y

    2000-01-01

    The author describes a method of calf augmentation by a silicone prosthesis implant for correction of asymmetrical legs or aesthetic problems. Preference is given to the placement of soft silicone implants (Glitzentein implants); they are more natural looking than hard implants. The implants are placed over both heads of the gastrocnemius muscle or beneath the fascia cruris superficialis. Operations were performed from November 1985 to August 1999. One hundred patients were studied: 95 female and 5 male. Two hundred calf implants were performed: 188 soft implants (Glitzenstein), 6 hard implants (Aiache), and 6 together on the same leg (Glitzenstein and Aiache implants). No infection problems, prosthesis rupture, or hematomas occurred. There were four seromas, but they disappeared in 15 days. Four prostheses were removed in two patients who did not like the final result. One prosthesis changed place, to the upper part of the calf. The operation is performed under sedative and local anesthesia, with an incision of approximately 4 to 5 cm in the popliteal pleat, at the same height as the fascia cruris. To date, no functional problem or muscular dysfunction has been provoked by silicone prosthesis implants. The patient walks 8 h after the surgery. We selected 500 patients who received implants in the legs with calf prostheses, fat implants, and prosthesis and fat implant together, during 14 years of follow-up, but the focus of this paper is a calf implant with prosthesis in 100 patients with 200 calf prosthesis implants.

  16. Qualitative and quantitative observations of bone tissue reactions to anodised implants.

    PubMed

    Sul, Young-Taeg; Johansson, Carina B; Röser, Kerstin; Albrektsson, Tomas

    2002-04-01

    Research projects focusing on biomaterials related factors; the bulk implant material, the macro-design of the implant and the microsurface roughness are routinely being conducted at our laboratories. In this study, we have investigated the bone tissue reactions to turned commercially pure (c.p.) titanium implants with various thicknesses of the oxide films after 6 weeks of insertion in rabbit bone. The control c.p. titanium implants had an oxide thickness of 17-200 nm while the test implants revealed an oxide thickness between 600 and 1000 nm. Routine histological investigations of the tissue reactions around the implants and enzyme histochemical detections of alkaline and acid phosphatase activities demonstrated similar findings around both the control and test implants. In general, the histomorphometrical parameters (bone to implant contact and newly formed bone) revealed significant quantitative differences between the control and test implants. The test implants demonstrated a greater bone response histomorphometrically than control implants and the osteoconductivity was more pronounced around the test implant surfaces. The parameters that differed between the implant surfaces, i.e. the oxide thickness, the pore size distribution, the porosity and the crystallinity of the surface oxides may represent factors that have an influence on the histomorphometrical results indicated by a stronger bone tissue response to the test implant surfaces, with an oxide thickness of more than 600 nm.

  17. Osseointegration of titanium implants functionalised with phosphoserine-tethered poly(epsilon-lysine) dendrons: a comparative study with traditional surface treatments in sheep.

    PubMed

    Stübinger, Stefan; Nuss, Katja; Bürki, Alexander; Mosch, Isabel; le Sidler, Miché; Meikle, Steve T; von Rechenberg, Brigitte; Santin, Matteo

    2015-02-01

    The aim of this study was to analyse the osseointegrative potential of phosphoserine-tethered dendrons when applied as surface functionalisation molecules on titanium implants in a sheep model after 2 and 8 weeks of implantation. Uncoated and dendron-coated implants were implanted in six sheep. Sandblasted and etched (SE) or porous additive manufactured (AM) implants with and without additional dendron functionalisation (SE-PSD; AM-PSD) were placed in the pelvic bone. Three implants per group were examined histologically and six implants were tested biomechanically. After 2 and 8 weeks the bone-to-implant contact (BIC) total values of SE implants (43.7±12.2; 53.3±9.0%) and SE-PSD (46.7±4.5; 61.7±4.9%) as well as AM implants (20.49±5.1; 43.9±9.7%) and AM-PSD implants (19.7±3.5; 48.3±15.6%) showed no statistically significant differences. For SE-PSD and AM-PSD a separate analysis of only the cancellous BIC demonstrated a statistically significant difference after 2 and 8 weeks. Biomechanical findings proved the overall increased stability of the porous implants after 8 weeks. Overall, the great effect of implant macro design on osseointegration was further supported by additional phosphoserine-tethered dendrons for SE and AM implants.

  18. Osseointegration of three-dimensional designed titanium implants manufactured by selective laser melting.

    PubMed

    Shaoki, Algabri; Xu, Jia-Yun; Sun, Haipeng; Chen, Xian-Shuai; Ouyang, Jianglin; Zhuang, Xiu-Mei; Deng, Fei-Long

    2016-10-27

    The selective laser melting (SLM) technique is a recent additive manufacturing (AM) technique. Several studies have reported success in the SLM-based production of biocompatible orthopaedic implants and three-dimensional bone defect constructs. In this study, we evaluated the surface properties and biocompatibility of an SLM titanium implant in vitro and compared them with those of a machined (MA) titanium control surface. In addition, we evaluated the osseointegration capability of the SLM implants in vivo and compared it with those of MA and Nobel-speedy (Nobel-S) implants. SLM microtopographical surface analysis revealed porous and high roughness with varied geometry compared with a smooth surface in MA Ti samples but with similar favourable wettability. Osteoblast proliferation and alkaline phosphatase activity were significantly enhanced on the SLM surface. Histological analysis of the bone-implant contact ratio revealed no significant difference among SLM, MA, and Nobel-S implants. Micro-CT assessment indicated that there was no significant difference in bone volume fraction around the implant among SLM implants and other types of surface modification implants. The removal torque value measurement of SLM implants was significantly lower that of than Nobel-S implants P < 0.001 and higher than that of MA implants. The study demonstrates the capability of SLM implants to integrate with living bone. The SLM technique holds promise as a new dental implant manufacturing technique.

  19. Randomized study on the effect of single-implant versus two-implant retained overdentures on implant loss and muscle activity: a 12-month follow-up report.

    PubMed

    Alqutaibi, A Y; Kaddah, A F; Farouk, M

    2017-06-01

    The objective was to evaluate and compare single- and two-implant retained overdentures for the rehabilitation of the edentulous mandible. Fifty-six edentulous subjects were eligible for inclusion. Using a random sampling system, a single implant or two implants were placed in the mandible. After 3 months, locator attachments were connected to the implants and the denture delivered with the retentive components incorporated in the denture base. Implant failure and muscle activity were evaluated at the 3-, 6-, and 12-month follow-up examinations. The study sample comprised 56 patients (32 male, 24 female), with a mean age of 58.2 years. A total of 84 implants were placed (28 in the single-implant group and 56 in the two-implant group). All patients completed the 12 months of follow-up. No significant differences were found between subjects in the two groups with respect to implant failure. With regard to improvements in muscle activity, the two-implant group showed statistically significant but perhaps not clinically important differences. Single-implant mandibular overdentures may be suggested as an alternative treatment modality for the rehabilitation of edentulous patients who cannot afford the cost of a two-implant overdenture. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  20. Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    PubMed

    Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit

    2015-05-01

    The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

  1. Predictability of short implants (< 10 mm) as a treatment option for the rehabilitation of atrophic maxillae. A systematic review

    PubMed Central

    García-Sala-Bonmatí, Fernando; Martínez-González, Amparo; García-Dalmau, Carlos; Mañes-Ferrer, José-Félix; Brotons-Oliver, Alejandro

    2016-01-01

    Background Short implants (< 10 mm) are one of the treatment options available in cases of limited vertical bone. A purpose of this paper is to evaluate the predictability of short implants as an alternative to technically molthough such implants are now widely used, there is controversy regarding their clinical reliability. There complex treatments in patients with atrophic maxillae, based on a systematic review of the literature and the analysis of the implant survival rates, changes in peri-implant bone level, and associated complications. It is postulated that short implants offer clinical results similar to those of longer implants. Material and Methods A Medline-PubMed search was made covering the period between January 2004 and December 2014 (both included). Studies in English published in indexed journals, involving at least 20 implants and with a follow-up period of at least 12 months were considered. A manual search in four high impact journals was also conducted. Results A total of 37 studies meeting the inclusion criteria were included in this review. 9792 implants placed in over 5000 patients were analyzed. Conclusions Based on the results of this review, short implants are seen to offer clinical results in terms of survival, bone loss and complications similar to those of longer implants. Key words:Survival rate, clinical results, dental implants, oral implants, short implants, short lengt PMID:26946199

  2. Breast reconstruction - implants

    MedlinePlus

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... it harder to find a tumor if your breast cancer comes back. Getting breast implants does not take ...

  3. Heat generated during seating of dental implant fixtures.

    PubMed

    Flanagan, Dennis

    2014-04-01

    Frictional heat can be generated during seating of dental implants into a drill-prepared osteotomy. This in vitro study tested the heat generated by implant seating in dense bovine mandible ramus. A thermocouple was placed approximately 0.5 mm from the rim of the osteotomy during seating of each dental implant. Four diameters of implants were tested. The average temperature increases were 0.075°C for the 5.7-mm-diameter implant, 0.97°C for the 4.7-mm-diameter implant, 1.4°C for the 3.7-mm-diameter implant, and 8.6°C for the 2.5-mm-diameter implant. The results showed that heat was indeed generated and a small temperature rise occurred, apparently by the friction of the implant surface against the fresh-cut bone surface. Bone is a poor thermal conductor. The titanium of the implant and the steel of the handpiece are much better heat conductors. Titanium may be 70 times more heat conductive than bone. The larger diameter and displacement implant may act as a heat sink to draw away any heat produced from the friction of seating the implant at the bone-implant interface. The peak temperature duration was momentary, and not measured, but this was approximately less than 1 second. Except for the 2.5-mm-diameter implants, the temperature rises and durations were found to be below those previously deemed to be detrimental, so no clinically significant osseous damage would be expected during dental implant fixture seating of standard and large-diameter-sized implants. A 2.5-mm implant may generate detrimental heat during seating in nonvital bone, but this may be clinically insignificant in vital bone. The surface area and thermal conductivity are important factors in removing generated heat transfer at the bone-implant interface. The F value as determined by analysis of variance was 69.22, and the P value was less than .0001, demonstrating significant differences between the groups considered as a whole.

  4. Rehabilitation of postrior atrophic edentulous jaws: prostheses supported by 5 mm short implants or by longer implants in augmented bone? One-year results from a pilot randomised clinical trial.

    PubMed

    Esposito, Marco; Pellegrino, Gerardo; Pistilli, Roberto; Felice, Pietro

    2011-01-01

    To evaluate whether 5 mm short dental implants could be an alternative to augmentation with anorganic bovine bone and placement of at least 10 mm long implants in posterior atrophic jaws. Fifteen patients with bilateral atrophic mandibles (5-7 mm bone height above the mandibular canal), and 15 patients with bilateral atrophic maxillae (4-6 mm bone height below the maxillary sinus) and bone thickness of at least 8 mm, were randomised according to a splitmouth design to receive one to three 5 mm short implants or at least 10 mm long implants in augmented bone. Mandibles were vertically augmented with interpositional bone blocks and maxillary sinuses with particulated bone via a lateral window. Implants were placed after 4 months, submerged and loaded, after 4 months, with provisional prostheses. Four months later, definitive provisionally cemented prostheses were delivered. Outcome measures were: prosthesis and implant failures, any complication and peri-implant marginal bone level changes. In 5 augmented mandibles, the planned 10 mm long implants could not be placed and shorter implants (7 and 8.5 mm) had to be used instead. One year after loading no patient dropped out. Two long (8.5 mm in the mandible and 13 mm in the maxilla) implants and one 5 mm short maxillary implant failed. There were no statistically significant differences in failures or complications. Patients with short implants lost on average 1 mm of peri-implant bone and patients with longer implants lost 1.2 mm. This difference was statistically significant. This pilot study suggests that 1 year after loading, 5 mm short implants achieve similar if not better results than longer implants placed in augmented bone. Short implants might be a preferable choice to bone augmentation since the treatment is faster, cheaper and associated with less morbidity, however their long-term prognosis is unknown.

  5. Comparison of marginal bone loss between internal- and external-connection dental implants in posterior areas without periodontal or peri-implant disease.

    PubMed

    Kim, Dae-Hyun; Kim, Hyun Ju; Kim, Sungtae; Koo, Ki-Tae; Kim, Tae-Il; Seol, Yang-Jo; Lee, Yong-Moo; Ku, Young; Rhyu, In-Chul

    2018-04-01

    The purpose of this retrospective study with 4-12 years of follow-up was to compare the marginal bone loss (MBL) between external-connection (EC) and internal-connection (IC) dental implants in posterior areas without periodontal or peri-implant disease on the adjacent teeth or implants. Additional factors influencing MBL were also evaluated. This retrospective study was performed using dental records and radiographic data obtained from patients who had undergone dental implant treatment in the posterior area from March 2006 to March 2007. All the implants that were included had follow-up periods of more than 4 years after loading and satisfied the implant success criteria, without any peri-implant or periodontal disease on the adjacent implants or teeth. They were divided into 2 groups: EC and IC. Subgroup comparisons were conducted according to splinting and the use of cement in the restorations. A statistical analysis was performed using the Mann-Whitney U test for comparisons between 2 groups and the Kruskal-Wallis test for comparisons among more than 2 groups. A total of 355 implants in 170 patients (206 EC and 149 IC) fulfilled the inclusion criteria and were analyzed in this study. The mean MBL was 0.47 mm and 0.15 mm in the EC and IC implants, respectively, which was a statistically significant difference ( P <0.001). Comparisons according to splinting (MBL of single implants: 0.34 mm, MBL of splinted implants: 0.31 mm, P =0.676) and cement use (MBL of cemented implants: 0.27 mm, MBL of non-cemented implants: 0.35 mm, P =0.178) showed no statistically significant differences in MBL, regardless of the implant connection type. IC implants showed a more favorable bone response regarding MBL in posterior areas without peri-implantitis or periodontal disease.

  6. New orthopaedic implant management tool for computer-assisted planning, navigation, and simulation: from implant CAD files to a standardized XML-based implant database.

    PubMed

    Sagbo, S; Blochaou, F; Langlotz, F; Vangenot, C; Nolte, L-P; Zheng, G

    2005-01-01

    Computer-Assisted Orthopaedic Surgery (CAOS) has made much progress over the last 10 years. Navigation systems have been recognized as important tools that help surgeons, and various such systems have been developed. A disadvantage of these systems is that they use non-standard formalisms and techniques. As a result, there are no standard concepts for implant and tool management or data formats to store information for use in 3D planning and navigation. We addressed these limitations and developed a practical and generic solution that offers benefits for surgeons, implant manufacturers, and CAS application developers. We developed a virtual implant database containing geometrical as well as calibration information for orthopedic implants and instruments, with a focus on trauma. This database has been successfully tested for various applications in the client/server mode. The implant information is not static, however, because manufacturers periodically revise their implants, resulting in the deletion of some implants and the introduction of new ones. Tracking these continuous changes and keeping CAS systems up to date is a tedious task if done manually. This leads to additional costs for system development, and some errors are inevitably generated due to the huge amount of information that has to be processed. To ease management with respect to implant life cycle, we developed a tool to assist end-users (surgeons, hospitals, CAS system providers, and implant manufacturers) in managing their implants. Our system can be used for pre-operative planning and intra-operative navigation, and also for any surgical simulation involving orthopedic implants. Currently, this tool allows addition of new implants, modification of existing ones, deletion of obsolete implants, export of a given implant, and also creation of backups. Our implant management system has been successfully tested in the laboratory with very promising results. It makes it possible to fill the current gap that exists between the CAS system and implant manufacturers, hospitals, and surgeons.

  7. Mandibular single-implant overdentures: preliminary results of a randomised-control trial on early loading with different implant diameters and attachment systems.

    PubMed

    Alsabeeha, Nabeel H M; Payne, Alan G T; De Silva, Rohana K; Thomson, W Murray

    2011-03-01

    To determine surgical and prosthodontic outcomes of mandibular single-implant overdentures, opposing complete maxillary dentures, using a wide diameter implant and large ball attachment system compared with different regular diameter implants with standard attachment systems. Thirty-six edentulous participants (mean age 68 years, SD 9.2) were randomly assigned into three treatment groups (n=12). A single implant was placed in the mandibular midline of participants to support an overdenture using a 6-week loading protocol. The control group received Southern regular implants and standard ball attachments. One group received Southern 8-mm-wide implants and large ball attachments. Another group received Neoss regular implants and Locator attachments. Parametric and non-parametric tests of a statistical software package (SPSS) were used to determine between groups differences in marginal bone loss, implant stability, implant, and prosthodontic success (P<0.05). Implant success after 1 year was 75% for Southern regular implant (control) group; and 100% for the Southern wide and Neoss regular implant groups (P=0.038). Mean marginal bone loss at 1 year was 0.19 mm (SD 0.39) without significant differences observed. Implant stability quotient (ISQ) at baseline was significantly lower for the Southern regular (control) group than the other two groups (P=0.001; P=0.009). At 1 year, no significant difference in implant stability was observed (mean ISQ 74.6, SD 6.1). The change in implant stability from baseline to 1 year was significant for the control group (P=0.025). Prosthodontic success was comparable between the groups but the maintenance (41 events overall, mean 1.2) was greater for the Locator and the standard ball attachments. Mandibular single-implant overdentures are a successful treatment option for older edentulous adults with early loading protocol using implants of different diameters and with different attachment systems. © 2010 John Wiley & Sons A/S.

  8. Single-blind randomized clinical trial to evaluate clinical and radiological outcomes after one year of immediate versus delayed implant placement supporting full-arch prostheses

    PubMed Central

    Pellicer-Chover, Hilario; Peñarrocha-Oltra, David; Bagán, Leticia; Fichy-Fernandez, Antonio J.; Canullo, Luigi

    2014-01-01

    Purpose: To evaluate and compare peri-implant health, marginal bone loss and success of immediate and delayed implant placement for rehabilitation with full-arch fixed prostheses. Material and Methods: The present study was a prospective, randomized, single-blind, clinical preliminary trial. Patients were randomized into two treatment groups. In Group A implants were placed immediately post-extraction and in Group B six months after extraction. The following control time-points were established: one week, six months and twelve months after loading. Measurements were taken of peri-implant crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis. Implant success rates were evaluated for the two groups. The study sample included fifteen patients (nine women and six men) with a mean average age of 63.7 years. One hundred and forty-four implants were placed: 76 placed in healed sites and 68 placed immediately. Results: At the moment of prosthetic loading, keratinized mucosa width and probing depth were higher in immediate implants than delayed implants, with statistically significant differences. However, after six and twelve months, differences between groups had disappeared. Bone loss was 0.54 ± 0.39 mm for immediate implants and 0.66 ± 0.25 mm for delayed implants (p=0.201). No implants failed in either group. Conclusions: The present study with a short follow-up and a small sample yielded no statistically significant differences in implant success and peri-implant marginal bone loss between immediate and delayed implants with fixed full-arch prostheses. Peri-implant health showed no statistically significant differences for any of the studied parameters (crevicular fluid volume, plaque index, gingival retraction, keratinized mucosa, probing depth, modified gingival index and presence of mucositis) at the twelve-month follow-up. Key words:Immediate implants, delayed implants, peri-implant health, success rate. PMID:24316712

  9. Cochlear Implants.

    ERIC Educational Resources Information Center

    Clark, Catherine; Scott, Larry

    This brochure explains what a cochlear implant is, lists the types of individuals with deafness who may be helped by a cochlear implant, describes the process of evaluating people for cochlear implants, discusses the surgical process for implanting the aid, traces the path of sound through the cochlear implant to the brain, notes the costs of…

  10. Agile Development of Advanced Prototypes

    DTIC Science & Technology

    2014-11-01

    prostheses: retinal implants, cochlear implants, and neuroprosthetics (EEG controlled artificial limbs); an interactive, virtual experience...demonstrations allowing users to experience, from a patient’s perspective life with three different prostheses: retinal implants, cochlear implants...three experiences were researched and developed. The applications are interactive demonstrations of retinal implants, cochlear implants, and

  11. Diode Laser and Periodontal Regeneration-Assisted Management of Implant Complications in Anterior Maxilla.

    PubMed

    Salaria, Sanjeev Kumar; Sharma, Isha; Brar, Navjot Kaur; Kaur, Satwant

    2018-01-01

    Dental implant is being considered successful if the patient is pleased with both of its functional and esthetic outcome. As implant complications (such as peri-implantitis, inappropriate implant position, wrong angulation, and implant location too close to anatomical structures) have been frequently encountered in dental practice, therefore, thorough knowledge to manage such complications is the key prerequisite to prevent the failure of implant. The present case report discussed the etiology, diagnosis of early peri-implantitis, and periodontal abscess with their successful management through periodontal regeneration and diode laser-assisted therapy.

  12. Linguine sign at MR imaging: does it represent the collapsed silicone implant shell?

    PubMed

    Gorczyca, D P; DeBruhl, N D; Mund, D F; Bassett, L W

    1994-05-01

    One intact and one ruptured single-lumen implant were surgically placed in a rabbit. Magnetic resonance (MR) imaging was performed before and after surgical removal, and the ruptured implant was imaged after removal of the implant shell. Multiple curvilinear hypointense lines (linguine sign) were present in the MR images of the ruptured implant and of the implant shell alone immersed in saline solution but not in the image of the free silicone. The collapsed implant shell in a ruptured silicone implant does cause the linguine sign.

  13. Occlusion for implant-supported fixed dental prostheses in partially edentulous patients: a literature review and current concepts

    PubMed Central

    Sukotjo, Cortino

    2013-01-01

    Implant treatment has become the treatment of choice to replace missing teeth in partially edentulous areas. Dental implants present different biological and biomechanical characteristics than natural teeth. Occlusion is considered to be one of the most important factors contributing to implant success. Most literature on implant occlusal concepts is based on expert opinion, anecdotal experiences, in vitro and animal studies, and only limited clinical research. Furthermore, scientific literature regarding implant occlusion, particularly in implant-supported fixed dental prostheses remains controversial. In this study, the current status of implant occlusion was reviewed and discussed. Further randomized clinical research to investigate the correlation between implant occlusion, the implant success rate, and its risk factors is warranted to determine best clinical practices. PMID:23678387

  14. Multiscale design and multiobjective optimization of orthopedic hip implants with functionally graded cellular material.

    PubMed

    Arabnejad Khanoki, Sajad; Pasini, Damiano

    2012-03-01

    Revision surgeries of total hip arthroplasty are often caused by a deficient structural compatibility of the implant. Two main culprits, among others, are bone-implant interface instability and bone resorption. To address these issues, in this paper we propose a novel type of implant, which, in contrast to current hip replacement implants made of either a fully solid or a foam material, consists of a lattice microstructure with nonhomogeneous distribution of material properties. A methodology based on multiscale mechanics and design optimization is introduced to synthesize a graded cellular implant that can minimize concurrently bone resorption and implant interface failure. The procedure is applied to the design of a 2D left implanted femur with optimized gradients of relative density. To assess the manufacturability of the graded cellular microstructure, a proof-of-concept is fabricated by using rapid prototyping. The results from the analysis are used to compare the optimized cellular implant with a fully dense titanium implant and a homogeneous foam implant with a relative density of 50%. The bone resorption and the maximum value of interface stress of the cellular implant are found to be over 70% and 50% less than the titanium implant while being 53% and 65% less than the foam implant.

  15. Short-Term and Long-Term Effects of Orthopedic Biodegradable Implants

    PubMed Central

    Amini, Ami R.; Wallace, James S.; Nukavarapu, Syam P.

    2012-01-01

    Presently, orthopedic and oral/maxillofacial implants represent a combined $2.8 billion market, a figure expected to experience significant and continued growth. Although traditional permanent implants have been proved clinically efficacious, they are also associated with several drawbacks, including secondary revision and removal surgeries. Non-permanent, biodegradable implants offer a promising alternative for patients, as they provide temporary support and degrade at a rate matching tissue formation, and thus, eliminate the need for secondary surgeries. These implants have been in clinical use for nearly 25 years, competing directly with, or maybe even exceeding, the performance of permanent implants. The initial implantation of biodegradable materials, as with permanent materials, mounts an acute host inflammatory response. Over time, the implant degradation profile and possible degradation product toxicity mediate long-term biodegradable implant-induced inflammation. However, unlike permanent implants, this inflammation is likely to cease once the material disappears. Implant-mediated inflammation is a critical determinant for implant success. Thus, for the development of a proactive biodegradable implant that has the ability to promote optimal bone regeneration and minimal detrimental inflammation, a thorough understanding of short- and long-term inflammatory events is required. Here, we discuss an array of biodegradable orthopedic implants, their associated short- and long- term inflammatory effects, and methods to mediate these inflammatory events. PMID:22043969

  16. [Researches on biomechanics of micro-implant-bone interface and optimum design of micro implant's neck].

    PubMed

    Deng, Feng; Zhang, Lei; Zhang, Yi; Song, Jin-lin; Fan, Yuboa

    2007-07-01

    To compare and analyze the stress distribution at the micro-implant-bone interface based on the different micro-implant-bone conditioned under orthodontic load, and to optimize the design of micro implant's neck. An adult skull with all tooth was scanned by spiral CT, and the data were imported into computer for three-dimensional reconstruction with software Mimics 9.0. The three dimensional finite element models of three micro-implant-bone interfaces(initial stability, full osseointegration and fibrous integration) were analyzed by finite element analysis software ABAQUS6.5. The primary stress distributions of different micro-implant-bone conditions were evaluated when 2N force was loaded. Then the diameter less than 1.5 mm of the micro implant's neck was added with 0.2 mm, to compare the stress distribution of the modified micro-implant-bone interface with traditional type. The stress mostly concentrated on the neck of micro implant and the full osseointegration interface in all models showed the lowest strain level. Compared with the traditional type, the increasing diameter neck of the micro implant obviously decreased the stress level in all the three conditions. The micro-implant-bone interface and the diameter of micro implant's neck both are the important influence factors to the stress distribution of micro implant.

  17. Age or experience? The influence of age at implantation and social and linguistic environment on language development in children with cochlear implants.

    PubMed

    Szagun, Gisela; Stumper, Barbara

    2012-12-01

    The authors investigated the influence of social environmental variables and age at implantation on language development in children with cochlear implants. Participants were 25 children with cochlear implants and their parents. Age at implantation ranged from 6 months to 42 months ( M (age) = 20.4 months, SD = 22.0 months). Linguistic progress was assessed at 12, 18, 24, and 30 months after implantation. At each data point, language measures were based on parental questionnaire and 45-min spontaneous speech samples. Children's language and parents' child-directed language were analyzed. On all language measures, children displayed considerable vocabulary and grammatical growth over time. Although there was no overall effect of age at implantation, younger and older children had different growth patterns. Children implanted by age 24 months made the most marked progress earlier on, whereas children implanted thereafter did so later on. Higher levels of maternal education were associated with faster linguistic progress; age at implantation was not. Properties of maternal language input, mean length of utterance, and expansions were associated with children's linguistic progress independently of age at implantation. In children implanted within the sensitive period for language learning, children's home language environment contributes more crucially to their linguistic progress than does age at implantation.

  18. Implant Insertion Torque: Its Role in Achieving Primary Stability of Restorable Dental Implants.

    PubMed

    Greenstein, Gary; Cavallaro, John

    2017-02-01

    A literature review was conducted to determine the role of insertion torque in attaining primary stability of dental implants. The review is comprised of articles that discussed the amount of torque needed to achieve primary implant stability in healed ridges and fresh extraction sockets prior to immediate implant loading. Studies were appraised that addressed the effects of minimum and maximum forces that can be used to successfully place implants. The minimum torque that can be employed to attain primary stability is undefined. Forces ≥30 Ncm are routinely used to place implants into healed ridges and fresh extraction sockets prior to immediate loading of implants. Increased insertion torque (≥50 Ncm) reduces micromotion and does not appear to damage bone. In general, the healing process after implant insertion provides a degree of biologic stability that is similar whether implants are placed with high or low initial insertion torque. Primary stability is desirable when placing implants, but the absence of micromotion is what facilitates predictable implant osseointegration. Increased insertion torque helps achieve primary stability by reducing implant micromotion. Furthermore, tactile information provided by the first surgical twist drill can aid in selecting the initial insertion torque to achieve predictable stability of inserted dental implants.

  19. Breast Implants and the Risk of Anaplastic Large-Cell Lymphoma in the Breast.

    PubMed

    de Boer, Mintsje; van Leeuwen, Flora E; Hauptmann, Michael; Overbeek, Lucy I H; de Boer, Jan Paul; Hijmering, Nathalie J; Sernee, Arthur; Klazen, Caroline A H; Lobbes, Marc B I; van der Hulst, René R W J; Rakhorst, Hinne A; de Jong, Daphne

    2018-03-01

    Breast implants are among the most commonly used medical devices. Since 2008, the number of women with breast implants diagnosed with anaplastic large-cell lymphoma in the breast (breast-ALCL) has increased, and several reports have suggested an association between breast implants and risk of breast-ALCL. However, relative and absolute risks of breast-ALCL in women with implants are still unknown, precluding evidence-based counseling about implants. To determine relative and absolute risks of breast-ALCL in women with breast implants. Through the population-based nationwide Dutch pathology registry we identified all patients diagnosed with primary non-Hodgkin lymphoma in the breast between 1990 and 2016 and retrieved clinical data, including breast implant status, from the treating physicians. We estimated the odds ratio (OR) of ALCL associated with breast implants in a case-control design, comparing implant prevalence between women with breast-ALCL and women with other types of breast lymphoma. Cumulative risk of breast-ALCL was derived from the age-specific prevalence of breast implants in Dutch women, estimated from an examination of 3000 chest x-rays and time trends from implant sales. Relative and absolute risks of breast-ALCL in women with breast implants. Among 43 patients with breast-ALCL (median age, 59 years), 32 had ipsilateral breast implants, compared with 1 among 146 women with other primary breast lymphomas (OR, 421.8; 95% CI, 52.6-3385.2). Implants among breast-ALCL cases were more often macrotextured (23 macrotextured of 28 total implants of known type, 82%) than expected (49 193 sold macrotextured implants of total sold 109 449 between 2010 and 2015, 45%) based on sales data (P < .001). The estimated prevalence of breast implants in women aged 20 to 70 years was 3.3%. Cumulative risks of breast-ALCL in women with implants were 29 per million at 50 years and 82 per million at 70 years. The number of women with implants needed to cause 1 breast-ALCL case before age 75 years was 6920. Breast implants are associated with increased risk of breast-ALCL, but the absolute risk remains small. Our results emphasize the need for increased awareness among the public, medical professionals, and regulatory bodies, promotion of alternative cosmetic procedures, and alertness to signs and symptoms of breast-ALCL in women with implants.

  20. In vivo osseointegration of dental implants with an antimicrobial peptide coating.

    PubMed

    Chen, X; Zhou, X C; Liu, S; Wu, R F; Aparicio, C; Wu, J Y

    2017-05-01

    This study aimed to evaluate the in vivo osseointegration of implants with hydrophobic antimicrobial GL13K-peptide coating in rabbit femoral condyles by micro-CT and histological analysis. Six male Japanese Rabbits (4 months old and weighing 2.5 kg each) were included in this study. Twelve implants (3.75 mm wide, 7 mm long) were randomly distributed in two groups, with six implants in the experimental group coated with GL13K peptide and six implants in the control group without surface coating. Each implant in the test and the control group was randomly implanted in the left or right side of femoral condyles. On one side randomly-selected of the femur, each rabbit received a drill that was left without implant as control for the natural healing of bone. After 3 weeks of healing radiographic evaluation of the implant sites was taken. After 6 weeks of healing, rabbits were sacrificed for evaluation of the short-term osseointegration of the dental implants using digital radiography, micro-CT and histology analysis. To perform evaluation of osseointegration, implant location and group was double blinded for surgeon and histology/radiology researcher. Two rabbits died of wound infection in sites with non-coated implants 2 weeks after surgery. Thus, at least four rabbits per group survived after 6 weeks of healing. The wounds healed without suppuration and inflammation. No implant was loose after 6 weeks of healing. Radiography observations showed good osseointegration after 3 and 6 weeks postoperatively, which proved that the tissues followed a natural healing process. Micro-CT reconstruction and analysis showed that there was no statistically significant difference (P > 0.05) in volume of bone around the implant between implants coated with GL13K peptide and implants without coating. Histomorphometric analysis also showed that the mineralized bone area was no statistically different (P > 0.05) between implants coated with GL13K peptide and implants without coating. This study demonstrates that titanium dental implants with an antimicrobial GL13K coating enables in vivo implant osseointegration at similar bone growth rates than gold-standard non-coated dental implants up to 6 weeks of implantation in rabbit femurs.

  1. Performance of laser sintered Ti-6Al-4V implants with bone-inspired porosity and micro/nanoscale surface roughness in the rabbit femur

    PubMed Central

    Cohen, David J.; Cheng, Alice; Sahingur, Kaan; Clohessy, Ryan M.; Hopkins, Louis B.; Boyan, Barbara D.; Schwartz, Zvi

    2018-01-01

    Long term success of bone-interfacing implants remains a challenge in compromised patients and in areas of low bone quality. While surface roughness at the micro/nanoscale can promote osteogenesis, macro-scale porosity is important for promoting mechanical stability of the implant over time. Currently, machining techniques permit pores to be placed throughout the implant, but the pores are generally uniform in dimension. The advent of laser sintering provides a way to design and manufacture implants with specific porosity and variable dimensions at high resolution. This approach enables production of metal implants that mimic complex geometries found in biology. In this study, we used a rabbit femur model to compare osseointegration of laser sintered solid and porous implants. Ti-6Al-4V implants were laser sintered in a clinically relevant size and shape. One set of implants had a novel porosity based on human trabecular bone; both sets had grit-blasted/acid-etched surfaces. After characterization, implants were inserted transaxially into rabbit femora; mechanical testing, microCT and histomorphometry were conducted 10 weeks postoperatively. There were no differences in pull-out strength or bone-to-implant contact. However, both microCT and histomorphometry showed significantly higher new bone volume for porous compared to solid implants. Bone growth was observed into porous implant pores, especially near apical portions of the implant interfacing with cortical bone. These results show that laser sintered Ti-6Al-4V implants with micro/nanoscale surface roughness and trabecular bone-inspired porosity promote bone growth and may be used as a superior alternative to solid implants for bone-interfacing implants. PMID:28452335

  2. Performance of laser sintered Ti-6Al-4V implants with bone-inspired porosity and micro/nanoscale surface roughness in the rabbit femur.

    PubMed

    Cohen, David J; Cheng, Alice; Sahingur, Kaan; Clohessy, Ryan M; Hopkins, Louis B; Boyan, Barbara D; Schwartz, Zvi

    2017-04-28

    Long term success of bone-interfacing implants remains a challenge in compromised patients and in areas of low bone quality. While surface roughness at the micro/nanoscale can promote osteogenesis, macro-scale porosity is important for promoting mechanical stability of the implant over time. Currently, machining techniques permit pores to be placed throughout the implant, but the pores are generally uniform in dimension. The advent of laser sintering provides a way to design and manufacture implants with specific porosity and variable dimensions at high resolution. This approach enables production of metal implants that mimic complex geometries found in biology. In this study, we used a rabbit femur model to compare osseointegration of laser sintered solid and porous implants. Ti-6Al-4V implants were laser sintered in a clinically relevant size and shape. One set of implants had a novel porosity based on human trabecular bone; both sets had grit-blasted/acid-etched surfaces. After characterization, implants were inserted transaxially into rabbit femora; mechanical testing, micro-computed tomography (microCT) and histomorphometry were conducted 10 weeks post-operatively. There were no differences in pull-out strength or bone-to-implant contact. However, both microCT and histomorphometry showed significantly higher new bone volume for porous compared to solid implants. Bone growth was observed into porous implant pores, especially near apical portions of the implant interfacing with cortical bone. These results show that laser sintered Ti-6Al-4V implants with micro/nanoscale surface roughness and trabecular bone-inspired porosity promote bone growth and may be used as a superior alternative to solid implants for bone-interfacing implants.

  3. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length.

    PubMed

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-03-18

    To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System ® ). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results.

  4. Sacroiliac joint stability: Finite element analysis of implant number, orientation, and superior implant length

    PubMed Central

    Lindsey, Derek P; Kiapour, Ali; Yerby, Scott A; Goel, Vijay K

    2018-01-01

    AIM To analyze how various implants placement variables affect sacroiliac (SI) joint range of motion. METHODS An experimentally validated finite element model of the lumbar spine and pelvis was used to simulate a fusion of the SI joint using various placement configurations of triangular implants (iFuse Implant System®). Placement configurations were varied by changing implant orientation, superior implant length, and number of implants. The range of motion of the SI joint was calculated using a constant moment of 10 N-m with a follower load of 400 N. The changes in motion were compared between the treatment groups to assess how the different variables affected the overall motion of the SI joint. RESULTS Transarticular placement of 3 implants with superior implants that end in the middle of the sacrum resulted in the greatest reduction in range of motion (flexion/extension = 73%, lateral bending = 42%, axial rotation = 72%). The range of motions of the SI joints were reduced with use of transarticular orientation (9%-18%) when compared with an inline orientation. The use of a superior implant that ended mid-sacrum resulted in median reductions of (8%-14%) when compared with a superior implant that ended in the middle of the ala. Reducing the number of implants, resulted in increased SI joint range of motions for the 1 and 2 implant models of 29%-133% and 2%-39%, respectively, when compared with the 3 implant model. CONCLUSION Using a validated finite element model we demonstrated that placement of 3 implants across the SI joint using a transarticular orientation with superior implant reaching the sacral midline resulted in the most stable construct. Additional clinical studies may be required to confirm these results. PMID:29564210

  5. Implantable cardioverter defibrillator knowledge and end-of-life device deactivation: A cross-sectional survey.

    PubMed

    McEvedy, Samantha M; Cameron, Jan; Lugg, Eugene; Miller, Jennifer; Haedtke, Chris; Hammash, Muna; Biddle, Martha J; Lee, Kyoung Suk; Mariani, Justin A; Ski, Chantal F; Thompson, David R; Chung, Misook Lee; Moser, Debra K

    2018-01-01

    End-of-life implantable cardioverter defibrillator deactivation discussions should commence before device implantation and be ongoing, yet many implantable cardioverter defibrillators remain active in patients' last days. To examine associations among implantable cardioverter defibrillator knowledge, patient characteristics and attitudes to implantable cardioverter defibrillator deactivation. Cross-sectional survey using the Experiences, Attitudes and Knowledge of End-of-Life Issues in Implantable Cardioverter Defibrillator Patients Questionnaire. Participants were classified as insufficient or sufficient implantable cardioverter defibrillator knowledge and the two groups were compared. Implantable cardioverter defibrillator recipients ( n = 270, mean age 61 ± 14 years; 73% male) were recruited from cardiology and implantable cardioverter defibrillator clinics attached to two tertiary hospitals in Melbourne, Australia, and two in Kentucky, the United States. Participants with insufficient implantable cardioverter defibrillator knowledge ( n = 77, 29%) were significantly older (mean age 66 vs 60 years, p = 0.001), less likely to be Caucasian (77% vs 87%, p  = 0.047), less likely to have received implantable cardioverter defibrillator shocks (26% vs 40%, p = 0.031), and more likely to have indications of mild cognitive impairment (Montreal Cognitive Assessment score <24: 44% vs 16%, p < 0.001). Insufficient implantable cardioverter defibrillator knowledge was associated with attitudes suggesting unwillingness to discuss implantable cardioverter defibrillator deactivation, even during the last days towards end of life ( p < 0.05). Implantable cardioverter defibrillator recipients, especially those who are older or have mild cognitive impairment, often have limited knowledge about implantable cardioverter defibrillator deactivation. This study identified several potential teachable moments throughout the patients' treatment trajectory. An interdisciplinary approach is required to ensure that discussions about implantable cardioverter defibrillator deactivation issues are initiated at appropriate time points, with family members ideally also included.

  6. MEAT SCIENCE AND MUSCLE BIOLOGY SYMPOSIUM--anabolic implants and meat quality.

    PubMed

    Duckett, S K; Pratt, S L

    2014-01-01

    Anabolic implants are routinely used in the finishing phase of beef production to improve animal performance and feed efficiency. Implanting during the feedlot phase on average increases ADG 18%, feed intake 6%, feed efficiency 8%, carcass weight 5%, and ribeye area 4% compared with nonimplanted controls. Implants reduce the cost of beef production, which is important given current high feed costs and beef prices. In a 1996 review of 37 implant trials, the use of a combination (i.e., estrogenic and trenbolone acetate) implant increased returns by US$77/head compared with nonimplanted steers. If calculated using today's prices, a combination implant would increase returns by $163/head. However, concerns about potential negative effects of implants on marbling scores, quality grades, and tenderness exist. Changes in Warner-Bratzler shear force values of steaks from implanted steers are small (<0.5 kg) and appear related to an increase in initial tenderness, possibly due to hypertrophy of muscle fiber, instead of alterations in postmortem proteolysis. The increase in ribeye size observed with implanting may also reduce marbling scores through a dilution effect. The impact of anabolic implants on gene expression has shown that implanting downregulates expression of certain lipogenic genes (e.g., stearoyl-CoA desaturase, fatty acid synthetase, fatty acid elongase-6) in steers with low quality grades (Select-) but not in implanted steers with high quality grades (Choice-). Examination of the adipocyte's transcriptome has shown that 36 genes were differentially expressed due to implant treatment. More research is needed to further determine how anabolic implants alter lipogenic gene expression to address changes in marbling deposition with implant usage. Given our current high feed costs and cattle prices, anabolic implants are one of the most cost-effective technologies that can be used in beef production systems.

  7. Retrospective cohort study of the clinical performance of 1-stage dental implants.

    PubMed

    Carr, Alan B; Choi, Yong-Geun; Eckert, Steven E; Desjardins, Ronald P

    2003-01-01

    To evaluate long-term clinical performance of 1-stage dental implant prostheses at a single clinic, emphasizing clinical and demographic characteristics that affect implant survival. Dental records of all 308 patients (674 implants) treated with 1-stage implants at Mayo Clinic from October 1993 through May 2000 were reviewed from implant placement to last visit. Exposure and outcome variables affecting performance were collected separately to control bias in the data collection process. Additional confounding factors (age and sex) were adjusted with the stratified Cox proportional hazards model. Implant survival was determined by means of a Kaplan-Meier survival estimate. The log-rank test was used to determine the role of clinical and demographic variables in implant survival. The relative risk associated with the possible effect of clinical and demographic variables on implant survival was estimated with the Cox proportional hazards model. The implant survival rate (n = 654 implants) was 97% (mean +/- SD follow-up, 21.0 +/- 18.8 months; range, 1 to 78 months). Performance bias was limited because nearly all patients were treated by 1 prosthodontist. Two implants failed after loading (6 and 9 months). The incidence of complications was less than 4%. Among the implant failures, use of heterogeneous bone graft was associated with 4.8 times more failures than was use of autogenous bone graft (P = .04). After augmentation, delaying implant placement for 5 to 6 months resulted in 8.6 times more failures than the rate after earlier placement (P < .001). Retrospective review of the clinical performance of a 1-stage dental implant system yielded a 97% survival rate, with no failures noted after 13 months. Prosthetic complications were low, especially for fixed implant prostheses. Clinical performance of 1-stage dental implant prostheses between 1993 and 2000 demonstrated a high level of predictability.

  8. A Retrospective Analysis of Dental Implants Replacing Failed Implants in Grafted Maxillary Sinus: A Case Series.

    PubMed

    Manor, Yifat; Chaushu, Gavriel; Lorean, Adi; Mijiritzky, Eithan

    2015-01-01

    To evaluate the survival rate of dental implants replacing failed implants in grafted maxillary sinuses using the lateral approach vs nongrafted posterior maxillae. A retrospective analysis was conducted to study the survival of secondary dental implants inserted in the posterior maxilla in previously failed implant sites between the years 2000 and 2010. The study group consisted of patients who had also undergone maxillary sinus augmentation, and the control group consisted of patients in whom implants in the posterior maxilla had failed. Clinical and demographic data were analyzed using a structured form. Seventy-five patients with a total of 75 replaced implants were included in the study. The study group comprised 40 patients and the control group, 35 patients. None of the replaced implants in the study group failed, resulting in an overall survival of 100%; three replaced implants in the control group failed (92% survival). The main reason for the primary implant removal was lack of osseointegration (35 [87.5%] of 40 study group implants and 23 [65.7%] of 35 control group implants [P = .027]). The difference between the groups with regard to the timing of primary implant failure was statistically significant. The study group had more early failures of the primary implant than did the control group (77% vs 62%; P = .038). Dental implants replaced in the posterior maxilla had a high survival rate. A higher rate of survival was found in augmented maxillary sinus sites. Within the limits of the present study, it can be concluded that previous implant failures in the grafted maxillary sinus should not discourage practitioners from a second attempt.

  9. Group D. Initiator paper. Implants--peri-implant (hard and soft tissue) interactions in health and disease: the impact of explosion of implant manufacturers.

    PubMed

    Ivanovski, Saso

    2015-01-01

    1. The best-documented implants have a threaded solid screw-type design and are manufactured from commercially pure (grade IV) titanium. There is good evidence to support implants ≥ 6 mm in length, and ≥ 3 mm in diameter. 2. Integrity of the seal between the abutment and the implant is important for several reasons, including minimization of mechanical and biological complications and maintaining marginal bone levels. Although the ideal design features of the implant-abutment connection have not been determined, an internal connection, micro-grooves at the implant collar, and horizontal offset of the implant-abutment junction (platform switch) appear to impart favorable properties. 3. Implants with moderately rough implant surfaces provide advantages over machined surfaces in terms of the speed and extent of osseointegration. While the favorable performances of both minimally and moderately rough surfaces are supported by long-term data, moderately rough surfaces provide superior outcomes in compromised sites, such as the posterior maxilla. 4. Although plaque is critical in the progression of peri-implantitis, the disease has a multi-factorial aetiology, and may be influenced by poor integrity of the abutment/implant connection. Iatrogenic factors, such as the introduction of a foreign body. (e.g., cement) below the mucosal margin, can be important contributors. 5. Clinicians should exercise caution when using a particular implant system, ensuring that the implant design is appropriate and supported by scientific evidence. Central to this is access to and participation in quality education on the impact that implant characteristics can have on clinical outcomes. Caution should be exercised in utilizing non-genuine restorative componentry that may lead to a poor implant-abutment fit and subsequent technical and biological complications.

  10. Systematic review of the effectiveness of polyurethane-coated compared with textured silicone implants in breast surgery.

    PubMed

    Duxbury, Paula J; Harvey, James R

    2016-04-01

    Silicone gel implants are used worldwide for breast augmentation and breast reconstruction. Textured silicone implants are the most commonly placed implant, but polyurethane-coated implants are increasingly being used in an attempt to ameliorate the long-term complications associated with implant insertion. This systematic review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-analyses guidelines. Electronic searches of MEDLINE, EMBASE, the Cochrane Library and www.ClinicalTrials.gov were undertaken in March 2014 using keywords. Following data extraction, 18 studies were included in the review, including four core studies of textured silicone implants and five studies reporting outcomes for polyurethane-coated silicone implants. There are no clear data reporting revision rates in patients treated with polyurethane implants. In the primary reconstructive setting, capsular contracture rates with silicone implants are 10-15% at 6 years, whilst studies of polyurethane implants report rates of 1.8-3.4%. In the primary augmentation setting, core studies show a capsular contracture rate of 2-15% at 6 years compared with 0.4-1% in polyurethane-coated implants; however, the polyurethane studies are limited by their design and poor follow-up. The use of polyurethane implants should be considered a safe alternative to textured silicone implants. It is likely that an implant surface does influence short- and long-term outcomes; however, the extent of any benefit cannot be determined from the available evidence base. Future implant studies should target the short- and long-term benefits of implant surfacing by procedure with defined outcome measures; a head-to-head comparison would help clarify outcomes. Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Comparative evaluation of the effectiveness of the implantation in the lateral part of the mandible between short tissue level (TE) and bone level (BL) implant systems.

    PubMed

    Hadzik, Jakub; Botzenhart, Ute; Krawiec, Maciej; Gedrange, Tomasz; Heinemann, Friedhelm; Vegh, Andras; Dominiak, Marzena

    2017-09-01

    Short dental implants can be an alternative method of treatment to a vertical bone augmentation procedure at sites of reduced alveolar height. However, for successful treatment, an implant system that causes a minimal marginal bone loss (MBL) should be taken into consideration. The aim of the study has been to evaluate implantation effectiveness for bone level and tissue level short implants provided in lateral aspects of partially edentulous mandible and limited alveolar ridge height. The MBL and primary as well as secondary implant stability were determined in the study. Patients were randomly divided into two groups according to the method of treatment provided. Sixteen short Bone Level Implants (OsseoSpeed TX, Astra tech) and 16 short Tissue Level Implants (RN SLActive ® , Straumann) were successfully placed in the edentulous part of the mandible. The determination of the marginal bone level was based on radiographic evaluation after 12 and 36 weeks. Implant stability was measured immediately after insertion and after 12 weeks. The marginal bone level of Bone Level Implants was significantly lower compared to Tissue Level Implants. Furthermore, the Bone Level Implants had greater primary and secondary stability in comparison with Tissue Level Implants (Primary: 77.8 ISQ versus 66.5 ISQ; Secondary: 78.9 ISQ versus 73.9 ISQ, respectively). Since short Bone Level Implants showed a significantly decreased MBL 12 and 36 weeks after implantation as well as better results for the primary stability compared to Tissue Level Implants, they should preferentially be used for this mentioned indication. Copyright © 2017 Elsevier GmbH. All rights reserved.

  12. Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study.

    PubMed

    Marković, Aleksa; Calvo-Guirado, José Luís; Lazić, Zoran; Gómez-Moreno, Gerardo; Ćalasan, Dejan; Guardia, Javier; Čolic, Snježana; Aguilar-Salvatierra, Antonio; Gačić, Bojan; Delgado-Ruiz, Rafael; Janjić, Bojan; Mišić, Tijana

    2013-06-01

    The aim of this study was to investigate the relationship between surgical techniques and implant macro-design (self-tapping/non-self-tapping) for the optimization of implant stability in the low-density bone present in the posterior maxilla using resonance frequency analysis (RFA). A total of 102 implants were studied. Fifty-six self-tapping BlueSkyBredent® (Bredent GmbH&Co.Kg®, Senden, Germany) and 56 non-self-tapping Standard Plus Straumann® (Institut Straumann AG®, Waldenburg, Switzerland) were placed in the posterior segment of the maxilla. Implants of both types were placed in sites prepared with either lateral bone-condensing or with bone-drilling techniques. Implant stability measurements were performed using RFA immediately after implant placement and weekly during a 12-week follow-up period. Both types of implants placed after bone condensing achieved significantly higher stability immediately after surgery, as well as during the entire 12-week observation period compared with those placed following bone drilling. After bone condensation, there were no significant differences in primary stability or in implant stability after the first week between both implant types. From 2 to 12 postoperative weeks, significantly higher stability was shown by self-tapping implants. After bone drilling, self-tapping implants achieved significantly higher stability than non-self-tapping implants during the entire follow-up period. The outcomes of the present study indicate that bone drilling is not an effective technique for improving implant stability and, following this technique, the use of self-tapping implants is highly recommended. Implant stability optimization in the soft bone can be achieved by lateral bone-condensing technique, regardless of implant macro-design. © 2011 Wiley Periodicals, Inc.

  13. Machined versus roughened immediately loaded and finally restored single implants inserted flapless: Preliminary 6-month data from a split- mouth randomised controlled trial.

    PubMed

    Cannizzaro, Gioacchino; Felice, Pietro; Loi, Ignazio; Viola, Paolo; Ferri, Vittorio; Leone, Michele; Lazzarini, Matteo; Trullenque-Eriksson, Anna; Esposito, Marco

    To compare the outcome of immediately loaded single implants with a machined or a roughened surface. Fifty patients had two implant sites randomly allocated to receive flaplessplaced single Syra implants (Sweden & Martina), one with a machined and one with a roughened surface (sand-blasted with zirconia powder and acid etched), according to a split-mouth design. To be loaded immediately, implants had to be inserted with a torque superior to 50 Ncm. Implants were restored with definitive crowns in direct occlusal contact within 48 h. Patients were followed for 6 months after loading. Outcome measures were prosthetic and implant failures and complications. Two machined implants and four roughened implants were not loaded immediately. Six months after loading no dropout occurred. One implant loaded late, which had a rough implant surface, failed 20 days after loading (P (McNemar test) = 0.625; difference in proportions = -0.04; 95% CI: -0.15 to 0.07). Three crowns had to be remade on machined implants and four on roughened implants (P (McNemar test) = 1.000; difference in proportions = -0.02; 95% CI: -0.12 to 0.08). Three machined and five roughened implants experienced complications (P (McNemar test) = 0.625; difference in proportions = -0.04; 95% CI: -0.15 to 0.07). There were no statistically significant differences between groups for crown and implant losses as well as complications. Up to 6 months after loading both machined and roughened flapless-placed and immediately loaded single implants provided good and similar results, however, longer follow-ups are needed to evaluate the long-term prognosis of implants with different surfaces.

  14. Impact of Different Surgeons on Dental Implant Failure.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    To assess the influence of several factors on the prevalence of dental implant failure, with special consideration of the placement of implants by different dental surgeons. This retrospective study is based on 2,670 patients who received 10,096 implants at one specialist clinic. Only the data of patients and implants treated by surgeons who had inserted a minimum of 200 implants at the clinic were included. Kaplan-Meier curves were stratified with respect to the individual surgeon. A generalized estimating equation (GEE) method was used to account for the fact that repeated observations (several implants) were placed in a single patient. The factors bone quantity, bone quality, implant location, implant surface, and implant system were analyzed with descriptive statistics separately for each individual surgeon. A total of 10 surgeons were eligible. The differences between the survival curves of each individual were statistically significant. The multivariate GEE model showed the following variables to be statistically significant: surgeon, bruxism, intake of antidepressants, location, implant length, and implant system. The surgeon with the highest absolute number of failures was also the one who inserted the most implants in sites of poor bone and used turned implants in most cases, whereas the surgeon with the lowest absolute number of failures used mainly modern implants. Separate survival analyses of turned and modern implants stratified for the individual surgeon showed statistically significant differences in cumulative survival. Different levels of failure incidence could be observed between the surgeons, occasionally reaching significant levels. Although a direct causal relationship could not be ascertained, the results of the present study suggest that the surgeons' technique, skills, and/or judgment may negatively influence implant survival rates.

  15. The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs.

    PubMed

    Di Stefano, Danilo Alessio; Perrotti, Vittoria; Greco, Gian Battista; Cappucci, Claudia; Arosio, Paolo; Piattelli, Adriano; Iezzi, Giovanna

    2018-06-01

    Implant site preparation may be adjusted to achieve the maximum possible primary stability. The aim of this investigation was to study the relation among bone-to-implant contact at insertion, bone density, and implant primary stability intra-operatively measured by a torque-measuring implant motor, when implant sites were undersized or tapped. Undersized (n=14), standard (n=13), and tapped (n=13) implant sites were prepared on 9 segments of bovine ribs. After measuring bone density using the implant motor, 40 implants were placed, and their primary stability assessed by measuring the integral of the torque-depth insertion curve. Bovine ribs were then processed histologically, the bone-to-implant contact measured and statistically correlated to bone density and the integral. Bone-to-implant contact and the integral of the torque-depth curve were significantly greater for undersized sites than tapped sites. Moreover, a correlation between bone to implant contact, the integral and bone density was found under all preparation conditions. The slope of the bone-to-implant/density and integral/density lines was significantly greater for undersized sites, while those corresponding to standard prepared and tapped sites did not differ significantly. The integral of the torque-depth curve provided reliable information about bone-to-implant contact and primary implant stability even in tapped or undersized sites. The linear relations found among the parameters suggests a connection between extent and modality of undersizing and the corresponding increase of the integral and, consequently, of primary stability. These results might help the physician determine the extent of undersizing needed to achieve the proper implant primary stability, according to the planned loading protocol.

  16. A prospective clinical study to evaluate the performance of zirconium dioxide dental implants in single-tooth gaps.

    PubMed

    Gahlert, Michael; Kniha, Heinz; Weingart, Dieter; Schild, Sabine; Gellrich, Nils-Claudius; Bormann, Kai-Hendrik

    2016-12-01

    Dental implants have traditionally been made from titanium or its alloys, but recently full-ceramic implants have been developed with comparable osseointegration properties and functional strength properties to titanium. These ceramic implants may have advantages in certain patients and situations, for example, where esthetic outcomes are particularly important. The objective of this investigation was to evaluate the performance of a newly developed full-ceramic ZrO 2 monotype implant design (PURE Ceramic Implant; Institut Straumann AG, Basel, Switzerland) in single-tooth gaps in the maxilla and mandible. This was a prospective, open-label, single-arm study in patients requiring implant rehabilitation in single-tooth gaps. Full-ceramic implants were placed, with provisional and final prostheses inserted after 3 and 6 months, respectively. Crestal bone level was measured at implant placement and after 6 and 12 months. Implant survival and success were evaluated after 6 and 12 months. Further evaluations are planned after 24 and 36 months. Forty-six patients were screened for potential study participation, of whom 44 (17 men and 27 women, mean age 48 ± 14 years) were recruited into the study. The majority of implants (90.9%) were placed in the maxilla. The implant survival and implant success rate after 12 months were 97.6%. A minor change of the mean bone level occurred between implant loading (final prosthesis insertion after 6 months) and 12 months (-0.14 mm) after initial bone remodeling was observed between implant placement and loading (-0.88 mm). The results indicated that monotype ceramic implants can achieve clinical outcomes comparable to published outcomes of equivalent titanium implants. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Short Dental Implants Retaining Two-Implant Mandibular Overdentures in Very Old, Dependent Patients: Radiologic and Clinical Observation Up to 5 Years.

    PubMed

    Maniewicz, Sabrina; Buser, Ramona; Duvernay, Elena; Vazquez, Lydia; Loup, Angelica; Perneger, Thomas V; Schimmel, Martin; Müller, Frauke

    To describe the survival rate and peri-implant bone loss in very old patients dependent for their activities of daily living (ADL), treated with mandibular two-implant overdentures (IODs) in the context of a previously reported randomized controlled trial. A total of 19 patients received two interforaminal Straumann implants (Regular Neck, 4.1 mm diameter, 8 mm length) that were subsequently loaded with Locator attachments, transforming their preexisting inferior conventional denture into an IOD. The primary outcome measures were implant survival rate and radiographically assessed peri-implant bone loss. Secondary outcome measures included peri-implant probing depth and Plaque Index scores, as well as implant mobility. Nutritional state (body mass index and blood markers) and cognitive state (Mini-Mental State Examination) were also analyzed. The patient cohort comprised eight men and 11 women with a mean age of 85.7 ± 6.6 years. The implant survival rate up to 5 years was 94.7%, with one early and one late implant failure. The mean loss of peri-implant bone height was 0.17 mm per year (95% confidence interval: 0.09 to 0.24; P < .001). Peri-implant probing depth and Plaque Index scores were low and stable during the first 2 years, and thereafter increased continuously. Correlation analysis suggests that a reduced cognitive function and nutritional state are not a particular risk factor for accelerated peri-implant bone loss. The high implant survival and acceptable peri-implant health suggest that neither age nor dependency for the ADLs is a contraindication for the placement of implants. Nevertheless, close monitoring of the patients concerning a potential further functional decline precluding denture management and performing oral hygiene measures is advised.

  18. Bone healing at implants with a fluoride-modified surface: an experimental study in dogs.

    PubMed

    Berglundh, T; Abrahamsson, I; Albouy, J-P; Lindhe, J

    2007-04-01

    The aim of the present experiment was to study early stages of osseointegration to implants with a fluoride-modified surface. Six mongrel dogs, about 1-year old, were used. All mandibular premolars and the first mandibular molars were extracted. Three months later, mucoperiosteal flaps were elevated in one side of the mandible and six sites were identified for implant placement. The control implants (MicroThread) had a TiOblast surface, while the test implants (OsseoSpeed) had a fluoride-modified TiOblast surface. Both types of implants had a similar geometry, a diameter of 3.5 mm and were 8 mm long. Following installation, cover screws were placed and the flaps were adjusted and sutured to cover all implants. Four weeks after the first implant surgery, the installation procedure was repeated in the opposite side of the mandible. Two weeks later, biopsies were obtained and prepared for histological analysis. The void that occurred between the cut bone wall of the recipient site and the macro-threads of the implant immediately following implant installation was used to study early bone formation. It was demonstrated that the amount of new bone that formed in the voids within the first 2 weeks of healing was larger at fluoride-modified implants (test) than at TiOblast (control) implants. It was further observed that the amount of bone-to-implant contact that had been established after 2 weeks in the macro-threaded portion of the implant was significantly larger at the test implants than at the controls. It is suggested that the fluoride-modified implant surface promotes osseointegration in the early phase of healing following implant installation.

  19. Enhanced antitumor efficacy of poly(D,L-lactide-co-glycolide)-based methotrexate-loaded implants on sarcoma 180 tumor-bearing mice

    PubMed Central

    Gao, Li; Xia, Lunyang; Zhang, Ruhui; Duan, Dandan; Liu, Xiuxiu; Xu, Jianjian; Luo, Lan

    2017-01-01

    Purpose Methotrexate is widely used in chemotherapy for a variety of malignancies. However, severe toxicity, poor pharmacokinetics, and narrow safety margin of methotrexate limit its clinical application. The aim of this study was to develop sustained-release methotrexate-loaded implants and evaluate antitumor activity of the implants after intratumoral implantation. Materials and methods We prepared the implants containing methotrexate, poly(D,L-lactide-co-glycolide), and polyethylene glycol 4000 with the melt-molding technique. The implants were characterized with regards to drug content, morphology, in vitro, and in vivo release profiles. Differential scanning calorimetry (DSC) and Fourier transform infrared spectroscopy (FTIR) were carried out to investigate the physicochemical properties of the implants. Furthermore, the antitumor activity of the implants was tested in a sarcoma 180 mouse model. Results The implants were prepared as solid rods. Scanning electron microscopy images showed a smooth surface of the implant, suggesting that methotrexate was homogeneously dispersed in the polymeric matrix. The results of DSC and FTIR indicated that no significant interaction between methotrexate and the polymer was observed in the implants. Both in vitro and in vivo release profiles of the implants were characterized by burst release followed by sustained release of methotrexate. Intratumoral implantation of methotrexate-loaded implants could efficiently delay tumor growth. Moreover, an increase in the dose of implants led to a higher tumor suppression rate without additional systemic toxicity. Conclusion These results demonstrate that methotrexate-loaded implants had significant antitumor efficacy in a sarcoma 180 mouse model without dose-limiting side effects, and suggest that the implants could be potentially applied as an intratumoral delivery system to treat cancer. PMID:29118572

  20. Analysis of risk factors for cluster behavior of dental implant failures.

    PubMed

    Chrcanovic, Bruno Ramos; Kisch, Jenö; Albrektsson, Tomas; Wennerberg, Ann

    2017-08-01

    Some studies indicated that implant failures are commonly concentrated in few patients. To identify and analyze cluster behavior of dental implant failures among subjects of a retrospective study. This retrospective study included patients receiving at least three implants only. Patients presenting at least three implant failures were classified as presenting a cluster behavior. Univariate and multivariate logistic regression models and generalized estimating equations analysis evaluated the effect of explanatory variables on the cluster behavior. There were 1406 patients with three or more implants (8337 implants, 592 failures). Sixty-seven (4.77%) patients presented cluster behavior, with 56.8% of all implant failures. The intake of antidepressants and bruxism were identified as potential negative factors exerting a statistically significant influence on a cluster behavior at the patient-level. The negative factors at the implant-level were turned implants, short implants, poor bone quality, age of the patient, the intake of medicaments to reduce the acid gastric production, smoking, and bruxism. A cluster pattern among patients with implant failure is highly probable. Factors of interest as predictors for implant failures could be a number of systemic and local factors, although a direct causal relationship cannot be ascertained. © 2017 Wiley Periodicals, Inc.

  1. Implant-Abutment Contact Surfaces and Microgap Measurements of Different Implant Connections Under 3-Dimensional X-Ray Microtomography.

    PubMed

    Scarano, Antonio; Valbonetti, Luca; Degidi, Marco; Pecci, Raffaella; Piattelli, Adriano; de Oliveira, P S; Perrotti, Vittoria

    2016-10-01

    The presence of a microgap between implant and abutment could produce a bacterial reservoir which could interfere with the long-term health of the periimplant tissues. The aim of this article was to evaluate, by x-ray 3-dimensional microtomography, implant-abutment contact surfaces and microgaps at the implant-abutment interface in different types of implant-abutment connections. A total of 40 implants were used in this in vitro study. Ten implants presented a screw-retained internal hexagon abutment (group I), 10 had a Morse Cone taper internal connection (group II), 10 another type of Morse Cone taper internal connection (group III), and 10 had a screwed trilobed connection (group IV). In both types of Morse Cone internal connections, there was no detectable separation at the implant-abutment in the area of the conical connection, and there was an absolute congruity without any microgaps between abutment and implant. No line was visible separating the implant and the abutment. On the contrary, in the screwed abutment implants, numerous gaps and voids were present. The results of this study support the hypothesis that different types of implant-abutment joints are responsible for the observed differences in bacterial penetration.

  2. A review of nanostructured surfaces and materials for dental implants: surface coating, patterning and functionalization for improved performance.

    PubMed

    Rasouli, Rahimeh; Barhoum, Ahmed; Uludag, Hasan

    2018-05-10

    The emerging field of nanostructured implants has enormous scope in the areas of medical science and dental implants. Surface nanofeatures provide significant potential solutions to medical problems by the introduction of better biomaterials, improved implant design, and surface engineering techniques such as coating, patterning, functionalization and molecular grafting at the nanoscale. This review is of an interdisciplinary nature, addressing the history and development of dental implants and the emerging area of nanotechnology in dental implants. After a brief introduction to nanotechnology in dental implants and the main classes of dental implants, an overview of different types of nanomaterials (i.e. metals, metal oxides, ceramics, polymers and hydrides) used in dental implant together with their unique properties, the influence of elemental compositions, and surface morphologies and possible applications are presented from a chemical point of view. In the core of this review, the dental implant materials, physical and chemical fabrication techniques and the role of nanotechnology in achieving ideal dental implants have been discussed. Finally, the critical parameters in dental implant design and available data on the current dental implant surfaces that use nanotopography in clinical dentistry have been discussed.

  3. Effect of Induced Periimplantitis on Dental Implants With and Without Ultrathin Hydroxyapatite Coating.

    PubMed

    Madi, Marwa; Zakaria, Osama; Ichinose, Shizuko; Kasugai, Shohei

    2016-02-01

    The aim of this study was to compare the effect of ligature-induced periimplantitis on dental implants with and without hydroxyapatite (HA) coat. Thirty-two dental implants (3.3 mm wide, 13 mm long) with 4 surface treatments (8 implant/group) (M: machined, SA: sandblasted acid etched, S: sputter HA coat and P: plasma-sprayed HA coat) were inserted into canine mandibles. After 12 weeks, oral hygiene procedures were stopped and silk ligatures were placed around the implant abutments to allow plaque accumulation for the following 16 weeks. Implants with the surrounding tissues were retrieved and prepared for histological examination. Bone-to-implant contact (BIC) and implant surfaces were examined using scanning electron microscopy and energy dispersive x-ray spectroscopy. Histological observation revealed marginal bone loss and large inflammatory cell infiltrates in the periimplant soft tissue. Sputter HA implants showed the largest BIC (98.1%) and machined implant showed the smallest values (70.4%). After 28 weeks, thin sputter HA coat was almost completely dissolved, whereas plasma-sprayed HA coat showed complete thickness preservation. Thin sputter HA-coated implants showed more bone implant contact and less marginal bone loss than thick HA-coated implants under periimplantitis condition.

  4. Evaluation of single-tooth implants in the second molar region: a 5-year life-table analysis of a retrospective study.

    PubMed

    Koo, Ki-Tae; Wikesjö, Ulf M E; Park, Jang-Yeol; Kim, Tae-Il; Seol, Yang-Jo; Ku, Young; Rhyu, In-Chul; Chung, Chong-Pyoung; Lee, Yong-Moo

    2010-09-01

    To our knowledge, no study has evaluated the success or survival rate of single-tooth implants that replaced missing maxillary and mandibular second molars. The purpose of the present study was to evaluate the 1- to 5-year cumulative survival rate (CSR) for single-tooth implants placed in the second molar region and the effects of associated factors. Four hundred eighty-nine patients (298 males and 191 females; age range: 23 to 91 years; mean age: 47 years) who were admitted to the Seoul National University Dental Hospital between March 2003 and July 2008 and treated with single-tooth implants in the second molar region (227 maxillary implants and 294 mandibular implants; total: 521 implants) were included in the study. Thirty-two subjects received two implants each. A 1- to 5-year CSR was calculated using a life-table analysis. A comparison of CSRs between maxillary versus mandibular implants, one-stage versus two-stage implants, short (10 mm) implants, and standard-diameter (or=5.0 mm) implants was performed using Wilcoxon (Gehan) statistics. P <0.05 was considered significant. Fifteen of the 521 implants were lost between insertion and the follow-up examinations. The 1- to 5-year CSR was 95.1%. There were no statistically significant differences in CSRs between implants placed in maxillas and mandibles (96.3% versus 94.9%, respectively; P = 0.084), one- and two-stage implants (95.6% versus 94.7%, respectively; P = 0.267), short and long implants (100% versus 95.1%, respectively; P = 0.582), and standard- and wide-diameter implants (93.8% versus 96.8%, respectively; P = 0.065). Within the limitations of the study, the placement of single-tooth implants in the second molar region was an effective and reliable treatment modality. Also, associated factors such as implant diameter, length, and location (the maxilla versus the mandible) may not have an impact on the long-term success of implants.

  5. Comparative Clinical Study of Conventional Dental Implants and Mini Dental Implants for Mandibular Overdentures: A Randomized Clinical Trial.

    PubMed

    Aunmeungtong, Weerapan; Kumchai, Thongnard; Strietzel, Frank P; Reichart, Peter A; Khongkhunthian, Pathawee

    2017-04-01

    Dental implant-retained overdentures have been chosen as the treatment of choice for complete mandibular removable dentures. Dental implants, such as mini dental implants, and components for retaining overdentures, are commercially available. However, comparative clinical studies comparing mini dental implants and conventional dental implants using different attachment for implant-retained overdentures have not been well documented. To compare the clinical outcomes of using two mini dental implants with Equator ® attachments, four mini dental implants with Equator attachments, or two conventional dental implants with ball attachments, by means of a randomized clinical trial. Sixty patients received implant-retained mandibular overdentures in the interforaminal region. The patients were divided into three groups. In Groups 1 and 2, two and four mini dental implants, respectively, were placed and immediately loaded by overdentures, using Equator ® attachments. In Group 3, conventional implants were placed. After osseointegration, the implants were loaded by overdentures, using ball attachments. The study distribution was randomized and double-blinded. Outcome measures included changes in radiological peri-implant bone level from surgery to 12 months postinsertion, prosthodontic complications and patient satisfaction. The cumulative survival rate in the three clinical groups after one year was 100%. There was no significant difference (p < 0.05) in clinical results regarding the number (two or four) of mini dental implants with Equator attachments. However, there was a significant difference in marginal bone loss and patient satisfaction between those receiving mini dental implants with Equator attachments and conventional dental implants with ball attachments. The marginal bone resorption in Group 3 was significantly higher than in Groups 1 and 2 (p < 0.05); there were no significant differences between Groups 1 and 2. There was no significant difference in patient satisfaction between Groups 1 and 2 but it was significantly higher than that in Group3 (p < 0.05). Two and four mini dental implants can be immediately used successfully for retaining lower complete dentures, as shown after a 1-year follow up. © 2016 Wiley Periodicals, Inc.

  6. Titanium versus zirconia implants supporting maxillary overdentures: three-dimensional finite element analysis.

    PubMed

    Osman, Reham B; Elkhadem, Amr H; Ma, Sunyoung; Swain, Michael V

    2013-01-01

    The purpose of this study was to compare the stress and strain occurring in peri-implant bone and implants used to support maxillary overdentures. Three-dimensional finite element analysis (3D FEA) was used to compare one-piece zirconia and titanium implants. Two types of implants were simulated using a 3D FEA model: one-piece zirconia and titanium implants (diameter, 3.8 × 11.5 mm) with 2.25-mm diameter ball abutments. In each simulation four implants were placed bilaterally in the canine/premolar region of an edentulous maxillary model. Static loads were applied axially and 20 degrees buccolingually on the buccal slope of the lingual cusps of posterior teeth of the first quadrant. Von Mises stresses and equivalent strains generated in peri-implant bone and first principal stresses in the implants were calculated. Comparable stress and strain values were shown in the peri-implant bone for both types of implants. The maximum equivalent strain produced in the peri-implant region was mostly within the range for bone augmentation. Under oblique loading, maximum von Mises stresses and equivalent strain were more evident at the neck of the most distal implant on the loaded side. Under axial load, the stress and strain were transferred to the peri-implant bone around the apex of the implant. Maximum tensile stresses that developed for either material were well below their fracture strength. The highest stresses were mainly located at the distobuccal region of the neck for the two implant materials under both loading conditions. From a biomechanical point of view, ceramic implants made from yttrium-stabilized tetragonal polycrystalline zirconia may be a potential alternative to conventional titanium implants for the support of overdentures. This is particularly relevant for a select group of patients with a proven allergy to titanium. Prospective clinical studies are still required to confirm these in vitro results. Different simulations presenting various cortical bone thicknesses and implant designs are required to provide a better understanding of the biomechanics of zirconia implants.

  7. 2D FEA of evaluation of micromovements and stresses at bone-implant interface in immediately loaded tapered implants in the posterior maxilla

    PubMed Central

    Desai, Shrikar R.; Singh, Rika; Karthikeyan, I.

    2013-01-01

    Aim: The aim of the study is to evaluate the influence implant length on stress distribution at bone implant interface in single immediately loaded implants when placed in D4 bone quality. Materials and Methods: A 2-dimensional finite element models were developed to simulate two types of implant designs, standard 3.75 mm–diameter tapered body implants of 6 and 10 mm lengths. The implants were placed in D4 bone quality with a cortical bone thickness of 0.5 mm. The implant design incorporated microthreads at the crestal part and the rest of the implant body incorporated Acme threads. The Acme thread form has a 29° thread angle with a thread height half of the pitch; the apex and valley are flat. A 100 N of force was applied vertically and in the oblique direction (at an angle of 45°) to the long axis of the implants. The respective material properties were assigned. Micro-movements and stresses at the bone implant interface were evaluated. Results: The results of total deformation (micro-movement) and Von mises stress were found to be lower for tapered long implant (10 mm) than short implant (6 mm) while using both vertical as well as oblique loading. Conclusion: Short implants can be successfully placed in poor bone quality under immediate loading protocol. The novel approach of the combination of microthreads at the crestal portion and acme threads for body portion of implant fixture gave promising results. PMID:24174759

  8. Effect of Macrogeometry on the Surface Topography of Dental Implants.

    PubMed

    Naves, Marina Melo; Menezes, Helder Henrique Machado; Magalhães, Denildo; Ferreira, Jessica Afonso; Ribeiro, Sara Ferreira; de Mello, José Daniel Biasoli; Costa, Henara Lillian

    2015-01-01

    Because the microtopography of titanium implants influences the biomaterial-tissue interaction, surface microtexturing treatments are frequently used for dental implants. However, surface treatment alone may not determine the final microtopography of a dental implant, which can also be influenced by the implant macrogeometry. This work analyzed the effects on surface roughness parameters of the same treatment applied by the same manufacturer to implants with differing macro-designs. Three groups of titanium implants with different macro-designs were investigated using laser interferometry and scanning electron microscopy. Relevant surface roughness parameters were calculated for different regions of each implant. Two flat disks (treated and untreated) were also investigated for comparison. The tops of the threads and the nonthreaded regions of all implants had very similar roughness parameters, independent of the geometry of the implant, which were also very similar to those of flat disks treated with the same process. In contrast, the flanks and valleys of the threads presented larger irregularities (Sa) with higher slopes (Sdq) and larger developed surface areas (Sdr) on all implants, particularly for implants with threads with smaller heights. The flanks and valleys displayed stronger textures (Str), particularly on the implants with threads with larger internal angles. Parameters associated with the height of the irregularities (Sa), the slope of the asperities (Sdq), the presence of a surface texture (Str), and the developed surface area of the irregularities (Sdr) were significantly affected by the macrogeometry of the implants. Flat disks subjected to the same surface treatment as dental implants reproduced only the surface topography of the flat regions of the implants.

  9. Maxillary "All-On-Four" treatment using zygomatic implants. A mechanical analysis.

    PubMed

    de Moraes, P H; Olate, S; Nóbilo, M de Arruda; Asprino, L; de Moraes, M; Barbosa, J de Albergaría

    2016-04-01

    Zygomatic implants may be used for dental rehabilitation in atrophic maxillae. The aim of this study was to establish experimentally the areas of stress distribution using 2 kinds of "All-On-Four" maxillary procedures. The best position to insert the implants was selected using polyurethane craniomaxillary models and surgical guides were made. Group 1 was designed with two posterior zygomatic implants and two conventional anterior implants, and group 2 with two posterior zygomatic implants and two anterior zygomatic implants. A titanium bar was built to link the 4 implants in both groups. Photoelastic replicas of these models were made and the implants were inserted using the surgical guides. An Instrom 4411 testing machine was used to perform a unilateral compressive loading at the level of the right first molar until 2mm of displacement was obtained. Group 1 showed a high strain concentration in the right lateral orbital region at the level of the apex of the zygomatic implant. Less strain was noticed at the apical levels of the conventional implants in the anterior sector and of the contralateral zygomatic implant. Group 2 showed high strains in the lateral inferior orbital area. The load was low in the alveolar bone sector. Zygomatic bone and paranasal structures are loaded at high levels when zygomatic implants are used to stabilize a full maxillary prosthodontic rehabilitation on 4 implants. The use of 4 zygomatic implants loads the alveolar bone to a lower extent and seems better suited from a mechanical point of view than the use of 2 zygomatic implants. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  10. Traditional Postextractive Implant Site Preparation Compared with Pre-extractive Interradicular Implant Bed Preparation in the Mandibular Molar Region, Using an Ultrasonic Device: A Randomized Pilot Study.

    PubMed

    Scarano, Antonio

    The immediate placement of single postextractive implants is increasing in the everyday clinical practice. Due to insufficient bone tissue volume, proper primary stability, essential for subsequent osseointegration, is sometimes not reached. The aim of this work was to compare two different approaches: implant bed preparation before and after root extraction. Twenty-two patients of both sexes were selected who needed an implant-prosthetic rehabilitation of the fractured first mandibular molar or presented an untreatable endodontic pathology. The sites were randomly assigned to the test group (treated with implant bed preparation before molar extractions) or control group (treated with implant bed preparation after molar extractions) by a computer-generated table. All implants were placed by the same operator, who was experienced in both traditional and ultrasonic techniques. The implant stability quotient (ISQ) and the position of the implant were evaluated. Statistical analysis was carried out. In the control group, three implants were placed in the central portion of the bone septum, while eight implants were placed with a tilted axis in relation to the septum; in the test group, all implants were placed in ideal positions within the root extraction sockets. The different position of the implants between the two procedures was statistically significant. This work presented an innovative approach for implant placement at the time of mandibular molar extraction. Preparing the implant bed with an ultrasonic device before root extraction is a simple technique and also allows greater stability to be reached in a selective case.

  11. Influence of metals on cytokines production in connection with successful implantation therapy in dentistry.

    PubMed

    Podzimek, Stepan; Tomka, Milan; Nemeth, Tibor; Himmlova, Lucie; Matucha, Petr; Prochazkova, Jarmila

    2010-01-01

    In most of patients in need of implantation treatment in the oral cavity, implants heal well, nevertheless, there are some individuals, in whom titanium implants fail for reasons, which remain unclear. The aim of our study was to determine if there is a difference between metal influenced IL-1β, IL-4, IL-6, TNF-α and IFN-γ cytokines production in patients with successfully healed implants compared to those, whose implant therapy was unsuccessful. The two study groups included 12 patients with failed dental titanium implants and 9 patients with successfully healed implants. In the subjects, cytokine production was established after lymphocyte cultivation with mercury, nickel and titanium antigens. IL-1β levels were significantly increased in all patients after stimulation with titanium and in patients with accepted implants compared to patients with failed implants after the stimulation with mercury and titanium. Titanium caused significantly increased IL-6 production in all patients. TNF-α and IFN-γ levels were also significantly increased after the stimulation with titanium. Significantly increased TNF-α levels were found in patients with accepted implants as compared to patients with failed implants. Increased production of IL-1β a IL-6 cytokines in reaction to titanium and increased production of TNF-α and IFN-γ cytokines in reaction to mercury, which is very often present in the form of amalgam in the oral cavity of persons in need of implant therapy, can play an important role in immune reactions during implant healing process. In patients with failed titanium implants, decreased production of these cytokines may participate in implant failure.

  12. A Different Approach for Usage of the Implant Materials: The Composite Graft Prefabrication.

    PubMed

    Deniz, Lutfi Murat; Ataman, Murat Görkem; Borman, Huseyin; Erinanç, Hilal

    2016-10-01

    With all implanted materials, a certain sequence of biological events occurs following the implantation. This process is destructive to the implant and peri-implant tissues. The aforementioned sequence of biological events may be responsible for the complications. In this study, the natural biologic process following implantation was completed in an area other than the final implantation area. The aim was to keep the peri-implant tissues in the final implantation area away from the process. In the control group, the porous polyethylene discs were implanted to subcutaneous area on the frontal bone of the rats. A month after the implantation, macroscopic and microscopic examinations were performed. In the study group, the discs were implanted primarily above the rectus abdominis muscle of the rats. It was named as "the composite graft prefabrication." Twenty-one days after the first implantation, the discs were removed from the rectus muscle and implanted to subcutaneous area on the frontal bone of the rats. A month after the final implantation, macroscopic and microscopic examinations were performed. In macroscopic examination, all possible complications were evaluated. In microscopic examination, apoptosis, fibrosis, inflammation, and fibrovascular in-growing were evaluated. In the control group, implant exposure was observed in 3 of the rats. In the study group, no complications were observed. Although there was no statistical difference between 2 groups in the microscopic findings, at first glance, the inflammation seemed to be the factor responsible for the complication in the control group. According to the macroscopic results, the composite graft prefabrication seemed to be effective in preventing complications.

  13. Primary prevention of peri-implantitis: managing peri-implant mucositis.

    PubMed

    Jepsen, Søren; Berglundh, Tord; Genco, Robert; Aass, Anne Merete; Demirel, Korkud; Derks, Jan; Figuero, Elena; Giovannoli, Jean Louis; Goldstein, Moshe; Lambert, France; Ortiz-Vigon, Alberto; Polyzois, Ioannis; Salvi, Giovanni E; Schwarz, Frank; Serino, Giovanni; Tomasi, Cristiano; Zitzmann, Nicola U

    2015-04-01

    Over the past decades, the placement of dental implants has become a routine procedure in the oral rehabilitation of fully and partially edentulous patients. However, the number of patients/implants affected by peri-implant diseases is increasing. As there are--in contrast to periodontitis--at present no established and predictable concepts for the treatment of peri-implantitis, primary prevention is of key importance. The management of peri-implant mucositis is considered as a preventive measure for the onset of peri-implantitis. Therefore, the remit of this working group was to assess the prevalence of peri-implant diseases, as well as risks for peri-implant mucositis and to evaluate measures for the management of peri-implant mucositis. Discussions were informed by four systematic reviews on the current epidemiology of peri-implant diseases, on potential risks contributing to the development of peri-implant mucositis, and on the effect of patient and of professionally administered measures to manage peri-implant mucositis. This consensus report is based on the outcomes of these systematic reviews and on the expert opinion of the participants. Key findings included: (i) meta-analysis estimated a weighted mean prevalence for peri-implant mucositis of 43% (CI: 32-54%) and for peri-implantitis of 22% (CI: 14-30%); (ii) bleeding on probing is considered as key clinical measure to distinguish between peri-implant health and disease; (iii) lack of regular supportive therapy in patients with peri-implant mucositis was associated with increased risk for onset of peri-implantitis; (iv) whereas plaque accumulation has been established as aetiological factor, smoking was identified as modifiable patient-related and excess cement as local risk indicator for the development of peri-implant mucositis; (v) patient-administered mechanical plaque control (with manual or powered toothbrushes) has been shown to be an effective preventive measure; (vi) professional intervention comprising oral hygiene instructions and mechanical debridement revealed a reduction in clinical signs of inflammation; (vii) adjunctive measures (antiseptics, local and systemic antibiotics, air-abrasive devices) were not found to improve the efficacy of professionally administered plaque removal in reducing clinical signs of inflammation. Consensus was reached on recommendations for patients with dental implants and oral health care professionals with regard to the efficacy of measures to manage peri-implant mucositis. It was particularly emphasized that implant placement and prosthetic reconstructions need to allow proper personal cleaning, diagnosis by probing and professional plaque removal. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Silicone Gel-Filled Breast Implants

    MedlinePlus

    ... and Medical Procedures Implants and Prosthetics Breast Implants Silicone Gel-Filled Breast Implants Share Tweet Linkedin Pin ... sharing options Linkedin Pin it Email Print Description: Silicone gel-filled breast implants have a silicone outer ...

  15. Effectiveness of disinfection therapies and promotion of osteoblast growth on osseotite and nanotite implant surfaces.

    PubMed

    Lubin, Judith; Hernandez, Maria A; Drukteinis, Saulius E; Parker, William B; Murray, Peter E

    2014-08-01

    To evaluate the effectiveness of 4 procedures to disinfect implant surfaces intentionally inoculated with bacteria and afterward to evaluate osteoblast viability to the disinfected implant surfaces. Eighty-eight commercially pure Osseotite and Nanotite titanium implant discs were inoculated with Porphyromonas gingivalis. The implant surfaces were disinfected with EDTA, tetracycline, citric acid, or neodymium-doped yttrium aluminum garnet (Nd:YAG) laser. The implant discs were then placed in cultures of osteoblast cells. Osseotite implant discs were easier to disinfect compared with the Nanotite implant discs. Citric acid and tetracycline were the most effective solutions for the disinfection of P. gingivalis from the Osseotite implant discs. The Nanotite implant discs were the most difficult to disinfect, likely because of their chemical and physical properties. Citric acid and tetracycline were most effective for disinfecting the Osseotite implant discs, and further clinical research is needed to verify these effects in vivo. The Nd:YAG laser was the weakest disinfection method, and it is not recommended for disinfecting implant surfaces until its effectiveness is improved.

  16. Implantable Myoelectric Sensors (IMESs) for Intramuscular Electromyogram Recording

    PubMed Central

    Weir, Richard F. ff.; Troyk, Phil R.; DeMichele, Glen A.; Kerns, Douglas A.; Schorsch, Jack F.; Maas, Huub

    2011-01-01

    We have developed a multichannel electrogmyography sensor system capable of receiving and processing signals from up to 32 implanted myoelectric sensors (IMES). The appeal of implanted sensors for myoelectric control is that electromyography (EMG) signals can be measured at their source providing relatively cross-talk-free signals that can be treated as independent control sites. An external telemetry controller receives telemetry sent over a transcutaneous magnetic link by the implanted electrodes. The same link provides power and commands to the implanted electrodes. Wireless telemetry of EMG signals from sensors implanted in the residual musculature eliminates the problems associated with percutaneous wires, such as infection, breakage, and marsupialization. Each implantable sensor consists of a custom-designed application-specified integrated circuit that is packaged into a bio-compatible RF BION capsule from the Alfred E. Mann Foundation. Implants are designed for permanent long-term implantation with no servicing requirements. We have a fully operational system. The system has been tested in animals. Implants have been chronically implanted in the legs of three cats and are still completely operational four months after implantation. PMID:19224729

  17. Method for implantation of high dopant concentrations in wide band gap materials

    DOEpatents

    Usov, Igor [Los Alamos, NM; Arendt, Paul N [Los Alamos, NM

    2009-09-15

    A method that combines alternate low/medium ion dose implantation with rapid thermal annealing at relatively low temperatures. At least one dopant is implanted in one of a single crystal and an epitaxial film of the wide band gap compound by a plurality of implantation cycles. The number of implantation cycles is sufficient to implant a predetermined concentration of the dopant in one of the single crystal and the epitaxial film. Each of the implantation cycles includes the steps of: implanting a portion of the predetermined concentration of the one dopant in one of the single crystal and the epitaxial film; annealing one of the single crystal and the epitaxial film and implanted portion at a predetermined temperature for a predetermined time to repair damage to one of the single crystal and the epitaxial film caused by implantation and activates the implanted dopant; and cooling the annealed single crystal and implanted portion to a temperature of less than about 100.degree. C. This combination produces high concentrations of dopants, while minimizing the defect concentration.

  18. Evaluation of early bone response to fluoride-modified and anodically oxidized titanium implants through continuous removal torque analysis.

    PubMed

    Kwon, Taek-Ka; Lee, Hyo-Jung; Min, Seung-Ki; Yeo, In-Sung

    2012-10-01

    To compare between a bioactive and a bioinert implant with different geometries by continuous measurement of the removal torque and calculation of the angular momentum of each surfaced implant. Six New Zealand white rabbits were used in the study. Each rabbit received 2 implants. A bioactive fluoride-modified implant with a conical connection and microthread design was inserted into one tibia, and a bioinert anodically oxidized implant with an external connection design was inserted into the other. After 2 weeks of implant insertion, the removal torque values were continuously measured according to time. Using the time-torque curve resulting from the measurements, the maximum values were determined, and the angular momenta were calculated. The anodically oxidized implant had significantly higher peak removal torque and angular momentum values than the fluoride-modified implant (P < 0.05). The impact of the fluoride-modified bioactive implant on early bone response remains unclear. Considering the angular momentum of dental implants may assist in the elucidation of the effect of implant geometry on bone response.

  19. Cellular Responses Evoked by Different Surface Characteristics of Intraosseous Titanium Implants

    PubMed Central

    Feller, Liviu; Jadwat, Yusuf; Khammissa, Razia A. G.; Meyerov, Robin; Lemmer, Johan

    2015-01-01

    The properties of biomaterials, including their surface microstructural topography and their surface chemistry or surface energy/wettability, affect cellular responses such as cell adhesion, proliferation, and migration. The nanotopography of moderately rough implant surfaces enhances the production of biological mediators in the peri-implant microenvironment with consequent recruitment of differentiating osteogenic cells to the implant surface and stimulates osteogenic maturation. Implant surfaces with moderately rough topography and with high surface energy promote osteogenesis, increase the ratio of bone-to-implant contact, and increase the bonding strength of the bone to the implant at the interface. Certain features of implant surface chemistry are also important in enhancing peri-implant bone wound healing. It is the purpose of this paper to review some of the more important features of titanium implant surfaces which have an impact on osseointegration. PMID:25767803

  20. Survival of Dental Implants Placed in Grafted and Nongrafted Bone: A Retrospective Study in a University Setting.

    PubMed

    Tran, Duong T; Gay, Isabel C; Diaz-Rodriguez, Janice; Parthasarathy, Kavitha; Weltman, Robin; Friedman, Lawrence

    2016-01-01

    To compare dental implant survival rates when placed in native bone and grafted sites. Additionally, risk factors associated with dental implant loss were identified. This study was based on the hypothesis that bone grafting has no effect on implant survival rates. A retrospective chart review was conducted for patients receiving dental implants at the University of Texas, School of Dentistry from 1985 to 2012. Exclusion criteria included patients with genetic diseases, radiation and chemotherapy, or an age less than 18 years. To avoid misclassification bias, implants were excluded if bone grafts were only done at the same time of placement. Data on age, sex, tobacco use, diabetes, osteoporosis, anatomical location of the implant, implant length and width, bone graft, and professional maintenance were collected for analysis. A total of 1,222 patients with 2,729 implants were included. The cumulative survival rates at 5 and 10 years were 92% and 87% for implants placed in native bone and 90% and 79% for implants placed in grafted bone, respectively. The results from multivariate analysis (Cox regression) indicated no significant difference in survival between the two groups; having maintenance therapy after implant placement reduced the failure rate by 80% (P < .001), and using tobacco increased the failure rate by 2.6-fold (P = .001). There was no difference in the dental implant survival rate when implants were placed in native bone or bone-grafted sites. Smoking and lack of professional maintenance were significantly related to increased implant loss.

  1. Effects of Thread Depth in the Neck Area on Peri-Implant Hard and Soft Tissues: An Animal Study.

    PubMed

    Sun, Shan-Pao; Lee, Dong-Won; Yun, Jeong-Ho; Park, Kwang-Ho; Park, Kwang-Bum; Moon, Ik-Sang

    2016-11-01

    Implants with deep thread depth have been developed for the purpose of increasing total implant surface area. However, effects of implant thread depth remain controversial. The aim of this study is to examine effects of thread depth on peri-implant tissues in terms of bone-implant contact (BIC), bone-implant volume (BIV), and hard and soft tissue dimensions using comprehensive analyses, including microcomputed tomography (micro-CT). Five beagle dogs received experimental intramandibular implants 3 months after removal of their premolars and first molars (P 2 , P 3 , P 4 , and M 1 ). Two different types of implants were installed in each animal: deep threaded (DT) and shallow threaded (ST). Resonance frequency testing was performed on the day of implantation as well as 4 and 8 weeks after implantation. Intraoral radiography, micro-CT, and histomorphometry were used to evaluate peri-implant tissues 4 and 8 weeks after implantation. There were no significant differences in resonance frequency test results between the two groups. Although radiographic analysis showed no group differences, micro-CT (P = 0.01) and histomorphometry (P = 0.003) revealed the DT group had significantly lower BIC values than the ST group at 4 weeks. However, by 8 weeks, BIC values of the two groups did not differ significantly. No significant differences in BIV or soft tissue height were observed between the two groups at either time point. DT implants showed no benefits over ST implants when inserted in dog mandibles.

  2. Correlation between MRI results and intraoperative findings in patients with silicone breast implants.

    PubMed

    Lindenblatt, Nicole; El-Rabadi, Karem; Helbich, Thomas H; Czembirek, Heinrich; Deutinger, Maria; Benditte-Klepetko, Heike

    2014-01-01

    Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21-72) years, with a mean duration of implantation of 3.8 (range 1-28) years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%). In seven of 17 removed implants (41%), the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. Our results show that rupture of only the inner layers of the implant shell with integrity of the outer shell leads to a misdiagnosis on MRI. Correlation with clinical symptoms and the specific wishes of the patient should guide the indication for implant removal.

  3. Correlation between MRI results and intraoperative findings in patients with silicone breast implants

    PubMed Central

    Lindenblatt, Nicole; El-Rabadi, Karem; Helbich, Thomas H; Czembirek, Heinrich; Deutinger, Maria; Benditte-Klepetko, Heike

    2014-01-01

    Background Silicone gel breast implants may silently rupture without detection. This has been the main reason for magnetic resonance imaging (MRI) of the augmented or reconstructed breast. The aim of the present study was to investigate the accuracy of MRI for implant rupture. Methods Fifty consecutive patients with 85 silicone gel implants were included in the study. The mean age of the patients was 51 (range 21–72) years, with a mean duration of implantation of 3.8 (range 1–28) years. All patients underwent clinical examination and breast MRI. Intraoperative implant rupture was diagnosed by the operating surgeon. Results Nineteen of the 50 patients suffered from clinical symptoms. An implant rupture was diagnosed by MRI in 22 of 85 implants (26%). In seven of 17 removed implants (41%), the intraoperative diagnosis corresponded with the positive MRI result. However, only 57% of these patients were symptomatic. Ultrasound imaging of the harvested implants showed signs of interrupted inner layers of the implant despite integrity of the outer shell. By microsurgical separation of the different layers of the implant shell, we were able to reproduce this phenomenon and to produce signs of implant rupture on MRI. Conclusion Our results show that rupture of only the inner layers of the implant shell with integrity of the outer shell leads to a misdiagnosis on MRI. Correlation with clinical symptoms and the specific wishes of the patient should guide the indication for implant removal. PMID:25114595

  4. Assessment of a polyelectrolyte multilayer film coating loaded with BMP-2 on titanium and PEEK implants in the rabbit femoral condyle

    PubMed Central

    Guillot, R.; Pignot-Paintrand, I.; Lavaud, J.; Decambron, A.; Bourgeois, E.; Josserand, V.; Logeart-Avramoglou, D.; Viguier, E.; Picart, C.

    2016-01-01

    The aim of this study was to evaluate the osseointegration of titanium implants (Ti-6Al-4V, noted here TA6V) and poly(etheretherketone) PEEK implants induced by a BMP-2-delivering surface coating made of polyelectrolyte multilayer films. The in vitro bioactivity of the polyelectrolyte film-coated implants was assessed using the alkaline phosphatase assay. BMP-2-coated TA6V and PEEK implants with a total dose of 9.3 µg of BMP-2 were inserted into the femoral condyles of New Zealand white rabbits and compared to uncoated implants. Rabbits were sacrificed 4 and 8 weeks after implantation. Histomorphometric analyses on TA6V and PEEK implants and microcomputed tomography on PEEK implants revealed that the bone-to-implant contact and bone area around the implants were significantly lower for the BMP-2-coated implants than for the bare implants. This was confirmed by scanning electron microscopy imaging. This difference was more pronounced at 4 weeks in comparison to the 8-week time point. However, bone growth inside the hexagonal upper hollow cavity of the screws was higher in the case of the BMP-2 coated implants. Overall, this study shows that a high dose of BMP-2 leads to localized and temporary bone impairment, and that the dose of BMP-2 delivered at the surface of an implant needs to be carefully optimized. PMID:26965394

  5. Stress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length.

    PubMed

    Yoo, Jin Suk; Kwon, Kung-Rock; Noh, Kwantae; Lee, Hyeonjong; Paek, Janghyun

    2017-06-01

    The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. Test model was created with epoxy resin. The strain gauges made a tight contact with implant surfaces. A universal testing machine was used to exert a vertical pressure on the mandibular implant overdenture and the strain rate of the implants was measured. Means and standard deviations of the maximum micro-deformation rates were determined. 1) Locator attachment: The implants on the working side generally showed higher strain than those on the non-working side. Tensile force was observed on the mesial surface of the implant on the working side, and the compressive force was applied to the buccal surface and on the surfaces of the implant on the non-working side. 2) Bar/clip attachment: The implants on the both non-working and working sides showed high strain; all surfaces except the mesial surface of the implant on the non-working side showed a compressive force. To minimize the strain on implants in mandibular implant overdentures, the attachment of the implant should be carefully selected and the denture base should be extended as much as possible.

  6. A Comparative Analysis on Two Types of Oral Implants, Bone-Level and Tissue-Level, with Different Cantilever Lengths of Fixed Prosthesis.

    PubMed

    Mosavar, Alireza; Nili, Monireh; Hashemi, Sayed Raouf; Kadkhodaei, Mahmoud

    2017-06-01

    Depending on esthetic, anatomical, and functional aspects, in implant-prosthetic restoration of a completely edentulous jaw, the selection of implant type is highly important; however, bone- and tissue-level implants and their stress distribution in bone have not yet been comparatively investigated. Hence, finite element analysis was used to study the influence of cantilever length in a fixed prosthesis on stress distribution in peri-implant bone around these two types of oral implants. A 3D edentulous mandible was modeled. In simulations, a framework with four posterior cantilever lengths and two types of implants, bone-level and tissue-level, was considered. A compressive load was applied to the distal regions of the cantilevers, and the von-Mises stress of peri-implant bone was investigated. The independent t-test and the Pearson correlation coefficient analyzed the results (α = 0.05). Stresses in the cortical bone around the bone-level implants were greater than those in the tissue-level implants with the same cantilever length. In addition, by extending the cantilever length, the stress values in peri-implant bone increased. Therefore, when the cantilever was at its maximum length, the maximum stress was in cortical bone and around the bone-level distal implants. The results of the present study indicate that treatment with tissue-level implants is potentially more advantageous than with bone-level implants for implant-supported fixed prostheses. © 2015 by the American College of Prosthodontists.

  7. Synergistic effects of bisphosphonate and calcium phosphate nanoparticles on peri-implant bone responses in osteoporotic rats.

    PubMed

    Alghamdi, Hamdan S; Bosco, Ruggero; Both, Sanne K; Iafisco, Michele; Leeuwenburgh, Sander C G; Jansen, John A; van den Beucken, Jeroen J J P

    2014-07-01

    The prevalence of osteoporosis will increase within the next decades due to the aging world population, which can affect the bone healing response to dental and orthopedic implants. Consequently, local drug targeting of peri-implant bone has been proposed as a strategy for the enhancement of bone-implant integration in osteoporotic conditions. In the present study, an established in-vivo femoral condyle implantation model in osteoporotic and healthy bone is used to analyze the osteogenic capacity of titanium implants coated with bisphosphonate (BP)-loaded calcium phosphate nanoparticles (nCaP) under compromised medical conditions. After 4 weeks of implantation, peri-implant bone volume (%BV; by μCT) and bone area (%BA; by histomorphometry) were significantly increased within a distance of 500 μm from implant surfaces functionalized with BP compared to control implants in osteoporotic and healthy conditions. Interestingly, the deposition of nCaP/BP coatings onto implant surfaces increased both peri-implant bone contact (%BIC) and volume (%BV) compared to the deposition of nCaP or BP coatings individually, in osteoporotic and healthy conditions. The results of real-time PCR revealed similar osteogenic gene expression levels to all implant surfaces at 4-weeks post-implantation. In conclusion, simultaneous targeting of bone formation (by nCaP) and bone resorption (by BP) using nCaP/BP surface coatings represents an effective strategy for synergistically improvement of bone-implant integration, especially in osteoporotic conditions. Copyright © 2014 Elsevier Ltd. All rights reserved.

  8. Evaluation of bone loss in antibacterial coated dental implants: An experimental study in dogs.

    PubMed

    Godoy-Gallardo, Maria; Manzanares-Céspedes, Maria Cristina; Sevilla, Pablo; Nart, José; Manzanares, Norberto; Manero, José M; Gil, Francisco Javier; Boyd, Steven K; Rodríguez, Daniel

    2016-12-01

    The aim of this study was to evaluate the in vivo effect of antibacterial modified dental implants in the first stages of peri-implantitis. Thirty dental implants were inserted in the mandibular premolar sites of 5 beagle dogs. Sites were randomly assigned to Ti (untreated implants, 10units), Ti_Ag (silver electrodeposition treatment, 10units), and Ti_TSP (silanization treatment, 10units). Coated implants were characterized by scanning electron microscopy, interferometry and X-ray photoelectron spectroscopy. Two months after implant insertion, experimental peri-implantitis was initiated by ligature placement. Ligatures were removed 2months later, and plaque formation was allowed for 2 additional months. Clinical and radiographic analyses were performed during the study. Implant-tissue samples were prepared for micro computed tomography, backscattered scanning electron microscopy, histomorphometric and histological analyses and ion release measurements. X-ray, SEM and histology images showed that vertical bone resorption in treated implants was lower than in the control group (P<0.05). This effect is likely due to the capacity of the treatments to reduce bacteria colonization on the implant surface. Histological analysis suggested an increase of peri-implant bone formation on silanized implants. However, the short post-ligature period was not enough to detect differences in clinical parameters among implant groups. Within the limits of this study, antibacterial surface treatments have a positive effect against bone resorption induced by peri-implantitis. Copyright © 2016 Elsevier B.V. All rights reserved.

  9. Low-energy BF2, BCl2, and BBr2 implants for ultrashallow P+-N junctions

    NASA Astrophysics Data System (ADS)

    Nandan, S. R.; Agarwal, Vikas; Banerjee, Sanjay K.

    1997-08-01

    We have examined low energy BCl2 and BBr2 implants as a means of fabricating ultra-shallow P+-N junctions. Five keV and 9 keV BCl2 implants and 18 keV BBr2 implants have been compared to 5 keV BF2 implants to study the benefits of using these species. BCl2 and BBr2, being heavier species, have a lower projected range and produce more damage. The greater damage restricts channeling, resulting in shallower as-implanted profiles. The increased damage amorphizes the substrate at low implant doses which results in reduced transient enhanced diffusion (TED) during the post-implant anneal. Post-anneal SIMS profiles indicate a junction depth reduction of over 10 nm (at 5 X 1017 cm-3 background doping) for 5 keV BCl2 implants as compared to 5 keV BF2 implants. Annealed junctions as shallow as 10 nm have been obtained from the 18 keV BBr2 implants. The increased damage degrades the electrical properties of these junctions by enhancing the leakage current densities. BCl2 implanted junctions have leakage current densities of approximately 1 (mu) A/cm2 as compared to 10 nA/cm2 for the BF2 implants. BBr2 implants have a lower leakage density of approximately 50 nA/cm2. Low energy BBr2 implants offer an exciting alternative for fabricating low leakage, ultra-shallow P+-N junctions.

  10. Biomechanical 3-Dimensional Finite Element Analysis of Obturator Protheses Retained with Zygomatic and Dental Implants in Maxillary Defects

    PubMed Central

    Akay, Canan; Yaluğ, Suat

    2015-01-01

    Background The objective of this study was to investigate the stress distribution in the bone around zygomatic and dental implants for 3 different implant-retained obturator prostheses designs in a Aramany class IV maxillary defect using 3-dimensional finite element analysis (FEA). Material\\Methods A 3-dimensional finite element model of an Aramany class IV defect was created. Three different implant-retained obturator prostheses were modeled: model 1 with 1 zygomatic implant and 1 dental implant, model 2 with 1 zygomatic implant and 2 dental implants, and model 3 with 2 zygomatic implants. Locator attachments were used as a superstructure. A 150-N load was applied 3 different ways. Qualitative analysis was based on the scale of maximum principal stress; values obtained through quantitative analysis are expressed in MPa. Results In all loading conditions, model 3 (when compared models 1 and 2) showed the lowest maximum principal stress value. Model 3 is the most appropirate reconstruction in Aramany class IV maxillary defects. Two zygomatic implants can reduce the stresses in model 3. The distribution of stresses on prostheses were more rational with the help of zygoma implants, which can distribute the stresses on each part of the maxilla. Conclusions Aramany class IV obturator prosthesis placement of 2 zygomatic implants in each side of the maxilla is more advantageous than placement of dental implants. In the non-defective side, increasing the number of dental implants is not as suitable as zygomatic implants. PMID:25714086

  11. Long-term success of dental implants in patients with head and neck cancer after radiation therapy.

    PubMed

    Curi, M M; Condezo, A F B; Ribeiro, K D C B; Cardoso, C L

    2018-06-01

    The purpose of this study was to analyze the long-term success and factors potentially influencing the success of dental implants placed in patients with head and neck cancer who underwent radiation therapy with a minimum total dose of 50Gy during the years 1995-2010. Thirty-five patients (169 dental implants) were included in this study. Data on demographic characteristics, tumour type, radiation therapy, implant sites, implant dimensions, and hyperbaric oxygen therapy (HBOT) were obtained from the medical records and analyzed. Implant survival was estimated using Kaplan-Meier survival curves. Seventy-nine dental implants were placed in the maxilla and 90 in the mandible. The mean follow-up after implant installation was 7.4 years (range 0.3-14.7 years). The overall 5-year survival rate for all implants was 92.9%. Sex (P<0.001) and the mode of radiation therapy delivery (P=0.005) had a statistically significant influence on implant survival. Age, time of implantation after irradiation, implant brand and dimensions, and HBOT had no statistically significant influence on implant survival. Osseointegrated dental implants can be used successfully in the oral rehabilitation of patients with head and neck cancer with a history of radiation therapy. Risk factors such as sex and the mode of radiation therapy delivery can affect implant survival. Copyright © 2018 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  12. Evaluation of mandibular posterior single implants with two different surfaces: a 5-year comparative study.

    PubMed

    Jung, Ui-Won; Choi, Jung-Yoo; Kim, Chang-Sung; Cho, Kyoo-Sung; Chai, Jung-Kiu; Kim, Chong-Kwan; Choi, Seong-Ho

    2008-10-01

    Anatomic and biomechanical limitations can jeopardize successful single implantation in the mandibular posterior area. To overcome the limitations, the design and the surface of the fixtures were modified. This study evaluated the cumulative survival rate (CSR) of mandibular molars replaced with a sand-blasted, large-grit, acid-etched (SLA) single implant or an anodized (ANO) single implant and examined associated factors, such as the surface treatment, position, and length and diameter of the implants. One hundred ninety-three single implants restored with an SLA implant and 112 single implants restored with an ANO implant in the mandibular molar area were selected from subjects who had visited the Department of Periodontology, Dental Hospital of Yonsei University, from March 2001 through June 2006. In the SLA group, 123 and 70 implants were placed in the first and second molar area, respectively. In the ANO group, 55 and 57 implants were placed in the first and second molar area, respectively. The 1- to 6-year CSR of the SLA and ANO groups was calculated using the life-table analysis. In addition, associated factors, such as the surface treatment, position, and length and diameter of the implants, were compared and analyzed using the chi(2) test (P <0.05). Two of 193 implants in the SLA group failed, giving a CSR of 98.96%; four of 112 ANO implants failed, giving a CSR of 96.43%. There were no significant differences with regard to the surface treatment, position, and length and diameter of the implants. Despite the anatomic and biomechanical limitation in the mandibular posterior area, mandibular posterior single implants showed a high CSR during the observation period. Mandibular posterior single implants can be an effective and reliable treatment modality that is not affected by the surface treatment, position, or length and diameter of the implant.

  13. Biomechanical validation of finite element models for two silicone metacarpophalangeal joint implants.

    PubMed

    Hussein, A I; Stranart, J C; Meguid, S A; Bogoch, E R

    2011-02-01

    Silicone implants are used for prosthetic arthroplasty of metacarpophalangeal (MCP) joints severely damaged by rheumatoid arthritis. Different silicone elastomer MCP implant designs have been developed, including the Swanson and the NeuFlex implants. The goal of this study was to compare the in vitro mechanical behavior of Swanson and NeuFlex MCP joint implants. Three-dimensional (3D) finite element (FE) models of the silicone implants were modeled using the commercial software ANSYS and subjected to angular displacement from 0 deg to 90 deg. FE models were validated using mechanical tests of implants incrementally bent from 0 deg to 90 deg in a joint simulator. Swanson size 2 and 4 implants were compared with NeuFlex size 10 and 30 implants, respectively. Good agreement was observed throughout the range of motion for the flexion bending moment derived from 3D FE models and mechanical tests. From 30 deg to 90 deg, the Swanson 2 demonstrated a greater resistance to deformation than the NeuFlex 10 and required a greater bending moment for joint flexion. For larger implant sizes, the NeuFlex 30 had a steeper moment-displacement curve, but required a lower moment than the Swanson 4, due to implant preflexion. On average, the stress generated at the implant hinge from 30 deg to 90 deg was lower in the NeuFlex than in the Swanson. On average, starting from the neutral position of 30 deg for the preflexed NeuFlex implant, higher moments were required to extend the NeuFlex implants to 0 deg compared with the Swanson implants, which returned spontaneously to resting position. Implant toggling within the medullary canals was less in the NeuFlex than in the Swanson. The differential performance of these implants may be useful in implant selection based on the preoperative condition(s) of the joint and specific patient functional needs.

  14. Lateral forces exerted through ball or bar attachments in relation to the inclination of mini-implant underneath overdentures: in vitro study.

    PubMed

    Takagaki, Kyozo; Gonda, Tomoya; Maeda, Yoshinobu

    2015-09-01

    Lateral force to mini-implants should be avoided because mini-implants are weak mechanically because of its small diameter. Overdentures retained by mini-implants are usually formed using ball attachments. However, bar attachments can offer the advantage of splinting the mini-implants. This study examined the effect of attachments in withstanding these lateral forces in tilted mini-implants of overdentures. Strain gauges were attached to the mini-implants (2.5 × 18 mm) embedded in an acrylic resin block. Two mini-implants were inserted vertically (Control) or with one mini-implant inclined at 10° or 20° (10-inclined and 20-inclined, respectively). The female portions of the attachments were secured to the denture base. A prefabricated ball attachment and CAD/CAM-fabricated bar attachment were compared. A vertical load of 49 N was applied to the occlusal surface at a distance 10 mm away from the center of two mini-implants. The lateral force borne by the mini-implants was measured via the attached strain gauge. Mann-Whitney U-test and an analysis of Bonferroni correction were used to compare differences between the two attachments and among the three models (P < 0.05). The lateral force exerted to the inclined mini-implant was significantly greater than that borne by a vertical mini-implant for both attachment types. The lateral force on the 20° inclined mini-implants with bar attachments was smaller than that on mini-implants with ball attachments. Inclined mini-implants are subjected to greater stresses than vertical ones, and a bar attachment can reduce the lateral forces borne by the mini-implant when one mini-implant inclined at 20°. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Implant-supported maxillary overdentures retained with milled bars: maxillary anterior versus maxillary posterior concept--a retrospective study.

    PubMed

    Krennmair, Gerald; Krainhöfner, Martin; Piehslinger, Eva

    2008-01-01

    The aim of the present retrospective investigation was to evaluate implant-supported maxillary overdentures using either anterior (group 1) or posterior (group 2) maxillary implant placement. Maxillary overdentures were planned with support by either 4 implants placed in the maxillary anterior region (group 1) or 6 to 8 implants placed in augmented maxillary posterior regions (group 2, bilateral sinus augmentation) and anchored either on an anterior or on 2 bilaterally placed milled bars. Cumulative implant survival rate, peri-implant conditions (marginal bone loss, pocket depth, Plaque Index, Gingival Index, Bleeding Index, and Calculus Index) and the incidence and type of prosthodontic maintenance were assessed and compared for the 2 groups. In addition, the cumulative survival rate for implants placed in grafted regions was compared with that of implants placed in nongrafted regions. Thirty-four patients (16 for group 1 and 18 for group 2) with 179 implants were available for follow-up examination after a mean period of 42.1 +/- 20.1 months. Four initially placed implants failed to osseointegrate and were replaced, but no further losses were seen during the loading period, for a 5-year cumulative implant survival rate of 978%. No differences in implant survival rates were seen between either the group-1 (98.4%) and group-2 (97.4%) concepts or nongrafted (98.0%) and grafted (97.5%) implants. The peri-implant parameters showed a healthy soft tissue, good oral hygiene, and an acceptable degree of peri-implant marginal bone loss. The rigid fixation of all overdentures was associated with a low incidence of prosthodontic maintenance, without any significant differences between the 2 groups. In well-planned overdenture treatment programs, a high survival rate and excellent peri-implant conditions can be achieved for implants placed in the anterior or posterior maxilla. Rigid anchorage of maxillary overdentures either on an extended anterior milled bar or on 2 bilateral posterior milled bars provides for a low incidence of prosthodontic maintenance.

  16. Effect of insertion torque on titanium implant osseointegration: an animal experimental study.

    PubMed

    Duyck, Joke; Roesems, Rutger; Cardoso, Marcio V; Ogawa, Toru; De Villa Camargos, Germana; Vandamme, Katleen

    2015-02-01

    To evaluate the effect of implant insertion torque on the peri-implant bone healing and implant osseointegration. Bilaterally in the tibia of five adult New Zealand white rabbits, 20 implants were installed, subdivided into four groups, corresponding to two insertion torque conditions (low, < 10 Ncm vs. high > 50 Ncm) and 2 experimental periods (2 weeks vs. 4 weeks of healing). The implant insertion torque was determined by the surgical drill diameter relative to the implant diameter. Implant osseointegration was evaluated by quantitative histology (bone-to-implant contact with host bone [BIC-host], with neoformed bone [BIC-de novo], with both bone types [BIC-total], and peri-implant bone [BA/TA]). Every response was modelled over time using GEE (general estimation equation) with an unstructured variance-covariance matrix to correct for dependency between the measurements from one animal. The statistical significance level of α = 0.05 was applied. Significantly, more BIC-host and BIC-total were recorded for H implants compared with L implants after 2 week of healing (P = 0.010 and P = 0.0001, respectively). However, this result was no longer found for the extended healing period. Furthermore, BIC-total significantly increased over time for L implants (P < 0.00001). In contrast, the significant increase in BA/TA over time was found for H implants (P < 0.01). Finally, H insertion torque led to an increased BA/TA after 4 week of healing (P < 0.02) compared with the L insertion protocol. L insertion torque implants installed in the rabbit tibial bone osseointegrate with considerable de novo bone formation. This bone neoformation enables L implants to catch up, already during the early osseointegration stage, the initial inferior amount BIC contact compared with that of H implants. A negative impact of the created strain environment accompanying H insertion torque implant installation on the biological process of osseointegration could not be observed, at least not at tissue level. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Study on the neotype zirconia's implant coated nanometer hydroxyapatite ceramics

    NASA Astrophysics Data System (ADS)

    Zhu, J. W.; Yang, D. W.

    2007-07-01

    In recent years, biologic ceramics is a popular material of implants and bioactive surface modification of dental implant became a research emphasis, which aims to improve bioactivity of implants materials and acquire firmer implants-bone interface. The zirconia ceramic has excellent mechanical properties and nanometer HA ceramics is a bioceramic well known for its bioactivity, therefore, nanometer HA ceramics coating on zirconia, allows combining the excellent mechanical properties of zirconia substrates with its bioactivity. This paper shows a new method for implant shape design and bioactive modification of dental implants surface. Zirconia's implant substrate was prepared by sintered method, central and lateral tunnels were drilled in the zirconia hollow porous cylindrical implants by laser processing. The HA powders and needle-like HA crystals were made by a wet precipitation and calcining method. Its surface was coated with nanometer HA ceramics which was used brush HA slurry and vacuum sintering. Mechanical testing results revealed that the attachment strength of nanometer HA ceramics coated zirconia samples is high. SEM and interface observation after inserted experiment indicated that calcium and phosphor content increased and symmetrically around coated implant-bone tissue interface. A significantly higher affinity index was demonstrated in vivo by histomorphometric evaluation in coated versus uncoated implants. SEM analysis demonstrated better bone adhesion to the material in coated implant at any situation. In addition, the hollow porous cylindrical implant coated with nanometer HA ceramics increase the interaction of bone and implant, the new bone induced into the surface of hollow porous cylindrical implant and through the most tunnels filled into central hole. The branch-like structure makes the implant and bone a body, which increased the contact area and decreased elastic ratio. Therefore, the macroscopical and microcosmic nested structure of implant coated nanometer HA ceramics had increased biocompatibility and improved the osteointegration. It endows the implants with new vital activity.

  18. Salivary Concentration of Oxidative Stress Biomarkers in a Group of Patients with Peri-Implantitis: A Transversal Study.

    PubMed

    Sánchez-Siles, Mariano; Lucas-Azorin, Javier; Salazar-Sánchez, Noemi; Carbonell-Meseguer, Luis; Camacho-Alonso, Fabio

    2016-10-01

    The purpose of this study was to know if peri-implantitis causes an increase in the total salivary concentration of oxidative stress markers. Seventy patients, 28 men and 42 women, 60 of them with dental implants, 30 of which had peri-implantitis and 30 were healthy. The remaining 10 were the control group: healthy subjects without implants. The average number of implants per patient was 4.70 ± 2.29 in the peri-implantitis group and 2 70 ± 2.11 in the control group. Periodontal/peri-implant variables were assessed, including bleeding index, gingival index, clinical attachment level, probing depth, presence of pockets larger than 4 and 6 mm, pain to percussion, suppuration, gingival hyperplasia or granuloma, crestal bone loss (both mesially and distally), evaluated through periapical radiography. Saliva samples from the 70 subjects were collected for measurement of malondialdehyde high performance liquid chromatography (HPLC) and myeloperoxidase (enzyme-linked immunosorbent assay analysis) concentrations. Implants affected with peri-implantitis had an average follow-up of 26.40 ± 7.97 months. 4.12% of implants with peri-implantitis had a painful response to percussion. 2.06% showed suppuration; 25.77% had granuloma. The mean crestal bone loss in implants wtih peri-implantitis was 3.78 ± 1.17 mm. Total salivary malondialdehyde concentration in the peri-implantitis group (0.52 ± 0.37 μM/l) was slightly higher than that in the group with healthy implants (0.40 ± 0.16 μM/l) and also slightly higher than that in the group of healthy patients without implants (0.41 ± 0.79 μM/l), although the difference was not statistically significant, p value = .442. Myeloperoxidase concentration was slightly higher in the peri-implantitis group (12.32 ± 2.17 ng/ml) than in the group with healthy implants (11.54 ± 2.80 ng/ml) and the group of healthy patients without implants (11.86 ± 2.67 ng/ml), without statistically significant differences, p value = .584. The salivary concentration of oxidative stress markers in patients with peri-implantitis and without periodontitis is not higher than that found in healthy patients. © 2015 Wiley Periodicals, Inc.

  19. R&D on dental implants breakage

    NASA Astrophysics Data System (ADS)

    Croitoru, Sorin Mihai; Popovici, Ion Alexandru

    2017-09-01

    Most used dental implants for human dental prostheses are of two steps type: first step means implantation and, after several months healing and osseointegration, second step is prosthesis fixture. For sure, dental implants and prostheses are meant to last for a lifetime. Still, there are unfortunate cases when dental implants break. This paper studies two steps dental implants breakage and proposes a set of instruments for replacement and restoration of the broken implant. First part of the paper sets the input data of the study: structure of the studied two steps dental implants based on two Romanian patents and values of the loading forces found in practice and specialty papers. In the second part of the paper, using DEFORM 2D™ FEM simulation software, worst case scenarios of loading dental implants are studied in order to determine which zones and components of the dental implant set are affected (broken). Last part of the paper is dedicated to design and presentation of a set for extracting and cutting tools used to restore the broken implant set.

  20. Peri-implant bone formation and implant integration strength of peptide-modified p(AAM-co-EG/AAC) interpenetrating polymer network-coated titanium implants.

    PubMed

    Barber, Thomas A; Ho, James E; De Ranieri, Aladino; Virdi, Amarjit S; Sumner, Dale R; Healy, Kevin E

    2007-02-01

    Interpenetrating polymer networks (IPNs) of poly (acrylamide-co-ethylene glycol/acrylic acid) functionalized with an -Arg-Gly-Asp- (RGD) containing 15 amino acid peptides, derived from rat bone sialoprotein (bsp-RGD(15), were grafted to titanium implants in an effort to modulate bone formation in the peri-implant region in the rat femoral ablation model. Bone-implant contact (BIC) and bone formation within the medullary canal were determined using microcomputed tomography at 2 and 4 weeks postimplantation. BIC for bsp-RGD(15)-IPN implants was enhanced relative to hydroxyapatite tricalcium phosphate (HA-TCP) coated implants, but was similar to all other groups. Aggregate bone formation neither indicated a dose-dependent effect of bsp-RGD(15) nor a meaningful trend. Mechanical testing of implant fixation revealed that only the HA-TCP coated implants supported significant (>1 MPa) interfacial shear strength, despite exhibiting lower overall BIC, an indication that bone ingrowth into the rougher coating was the primary mode of implant fixation. While no evidence was found to support the hypothesis that bsp-RGD(15)-modified IPN coated implants significantly impacted bone-implant bonding, these results point to the lack of correlation between in vitro studies employing primary osteoblasts and in vivo wound healing in the peri-implant region. Copyright 2006 Wiley Periodicals, Inc.

  1. The effect of thread pattern upon implant osseointegration.

    PubMed

    Abuhussein, Heba; Pagni, Giorgio; Rebaudi, Alberto; Wang, Hom-Lay

    2010-02-01

    Implant design features such as macro- and micro-design may influence overall implant success. Limited information is currently available. Therefore, it is the purpose of this paper to examine these factors such as thread pitch, thread geometry, helix angle, thread depth and width as well as implant crestal module may affect implant stability. A literature search was conducted using MEDLINE to identify studies, from simulated laboratory models, animal, to human, related to this topic using the keywords of implant thread, implant macrodesign, thread pitch, thread geometry, helix angle, thread depth, thread width and implant crestal module. The results showed how thread geometry affects the distribution of stress forces around the implant. A decreased thread pitch may positively influence implant stability. Excess helix angles in spite of a faster insertion may jeopardize the ability of implants to sustain axial load. Deeper threads seem to have an important effect on the stabilization in poorer bone quality situations. The addition of threads or microthreads up to the crestal module of an implant might provide a potential positive contribution on bone-to to-implant contact as well as on the preservation of marginal bone; nonetheless this remains to be determined. Appraising the current literature on this subject and combining existing data to verify the presence of any association between the selected characteristics may be critical in the achievement of overall implant success.

  2. Comparison of Implant Stability Using Resonance Frequency Analysis: Osteotome Versus Conventional Drilling

    PubMed Central

    Sadeghi, Rokhsareh; Miremadi, Asghar

    2015-01-01

    Objectives: Implant primary stability is one of the important factors in achieving implant success. The osteotome technique may improve primary stability in patients with poor bone quality. The aim of this study was to compare implant stability using two different techniques namely osteotome versus conventional drilling in the posterior maxilla. Materials and Methods: In this controlled randomized clinical trial, 54 dental implants were placed in 32 patients; 29 implants were placed in the osteotome group and 25 in the conventional drilling group. Implant stability was assessed at four time intervals namely at baseline, one, two and three months after implant placement using resonance frequency analysis (RFA). Results: Primary stability based on implant stability quotient (ISQ) units was 71.4±7 for the osteotome group and 67.4±10 for the control group. There was no statistically significant difference between the two groups in implant stability at any of the measurement times. In each group, changes in implant stability from baseline to one month and also from two months to three months post-operatively were not significant but from one month to two months after implant placement, implant stability showed a significant increase in both groups. Conclusion: The results of this study revealed that in both techniques, good implant stability was achieved and osteotome technique did not have any advantage compared to conventional drilling in this regard. PMID:27148375

  3. Influence of controlled immediate loading and implant design on peri-implant bone formation.

    PubMed

    Vandamme, Katleen; Naert, Ignace; Geris, Liesbet; Vander Sloten, Jozef; Puers, Robert; Duyck, Joke

    2007-02-01

    Tissue formation at the implant interface is known to be sensitive to mechanical stimuli. The aim of the study was to compare the bone formation around immediately loaded versus unloaded implants in two different implant macro-designs. A repeated sampling bone chamber with a central implant was installed in the tibia of 10 rabbits. Highly controlled loading experiments were designed for a cylindrical (CL) and screw-shaped (SL) implant, while the unloaded screw-shaped (SU) implant served as a control. An F-statistic model with alpha=5% determined statistical significance. A significantly higher bone area fraction was observed for SL compared with SU (p<0.0001). The mineralized bone fraction was the highest for SL and significantly different from SU (p<0.0001). The chance that osteoid- and bone-to-implant contact occurred was the highest for SL and significantly different from SU (p<0.0001), but not from CL. When bone-to-implant contact was observed, a loading (SL versus SU: p=0.0049) as well as an implant geometry effect (SL versus CL: p=0.01) was found, in favour of the SL condition. Well-controlled immediate implant loading accelerates tissue mineralization at the interface. Adequate bone stimulation via mechanical coupling may account for the larger bone response around the screw-type implant compared with the cylindrical implant.

  4. Influence of custom-made implant designs on the biomechanical performance for the case of immediate post-extraction placement in the maxillary esthetic zone: a finite element analysis.

    PubMed

    Chen, Jianyu; Zhang, Zhiguang; Chen, Xianshuai; Zhang, Xiao

    2017-05-01

    Due to the increasing adoption of immediate implantation strategies and the rapid development of the computer aided design/computer aided manufacturing technology, a therapeutic concept based on patient-specific implant dentistry has recently been reintroduced by many researchers. However, little information is available on the designs of custom-made dental implant systems, especially their biomechanical behavior. The influence of the custom-made implant designs on the biomechanical performance for both an immediate and a delayed loading protocol in the maxillary esthetic zone was evaluated by means of the finite element (FE) method. FE models of three dental implants were considered: a state of the art cylindrical implant and two custom-made implants designed by reverse engineering technology, namely a root-analogue implant and a root-analogue threaded implant. The von Mises stress distributions and micro-motions around the bone-implant interfaces were calculated using ANSYS software. In a comparison of the three implant designs for both loading protocols, a favorable biomechanical performance was observed for the use of root-analogue threaded implant which approximated the geometry of natural anterior tooth and maintained the original long-axis. The results indicated that bone-implant interfacial micro-motion was reduced and a favorable stress distribution after osseointegration was achieved.

  5. Effect of healing time on bone-implant contact of orthodontic micro-implants: a histologic study.

    PubMed

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability.

  6. Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis.

    PubMed

    Akça, Kivanç; Chang, Ting-Ling; Tekdemir, Ibrahim; Fanuscu, Mete I

    2006-08-01

    The objective of this biomechanical study was to explore the effect of bone micro-morphology on initial intraosseous stability of implants with different designs. Straumann and Astra Tech dental implants were placed into anterior and posterior regions of completely edentulous maxilla and mandible of a human cadaver. Experiments were undertaken to quantify initial implant stability and bone micro-morphology. Installation torque values (ITVs) and implant stability quotients (ISQs) were measured to determine initial intraosseous implant stability. For quantification of relative bone volume and micro-architecture, sectioned implant-bone and bone core specimens of each implant placement site were consecutively scanned and trabecular bone was analyzed in a micro-computed tomography (micro-CT) unit. Experimental outcomes were evaluated for correlations among implant designs, initial intraosseous implant stability and bone micro-structural parameters. ITVs correlated higher with bone volume fraction (BV/TV) than ISQs, at 88.1% and 68.9% levels, respectively. Correlations between ITVs and micro-morphometric parameters were significant at the 95% confidence level (P<0.05) while ISQs were not. Differences in ITVs, ISQs and BV/TV data in regards to implant designs used were not significant at the 95% confidence level (P>0.05). Bone micro-morphology has a prevailing effect over implant design on intraosseus initial implant stability, and ITV is more sensitive in terms of revealing biomechanical properties at the bone-implant interface in comparison with ISQ.

  7. The quantitative assessment of peri-implant bone responses using histomorphometry and micro-computed tomography.

    PubMed

    Schouten, Corinne; Meijer, Gert J; van den Beucken, Jeroen J J P; Spauwen, Paul H M; Jansen, John A

    2009-09-01

    In the present study, the effects of implant design and surface properties on peri-implant bone response were evaluated with both conventional histomorphometry and micro-computed tomography (micro-CT), using two geometrically different dental implants (Screw type, St; Push-in, Pi) either or not surface-modified (non-coated, CaP-coated, or CaP-coated+TGF-beta1). After 12 weeks of implantation in a goat femoral condyle model, peri-implant bone response was evaluated in three different zones (inner: 0-500 microm; middle: 500-1000 microm; and outer: 1000-1500 microm) around the implant. Results indicated superiority of conventional histomorphometry over micro-CT, as the latter is hampered by deficits in the discrimination at the implant/tissue interface. Beyond this interface, both analysis techniques can be regarded as complementary. Histomorphometrical analysis showed an overall higher bone volume around St compared to Pi implants, but no effects of surface modification were observed. St implants showed lowest bone volumes in the outer zone, whereas inner zones were lowest for Pi implants. These results implicate that for Pi implants bone formation started from two different directions (contact- and distance osteogenesis). For St implants it was concluded that undersized implantation technique and loosening of bone fragments compress the zones for contact and distant osteogenesis, thereby improving bone volume at the interface significantly.

  8. Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force.

    PubMed

    Lu, Ying-juan; Chang, Shao-hai; Ye, Jian-tao; Ye, Yu-shan; Yu, Yan-song

    2015-01-01

    Stress on the bone surrounding dental micro-implants affects implant success. To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm.

  9. Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force

    PubMed Central

    Lu, Ying-juan; Chang, Shao-hai; Ye, Jian-tao; Ye, Yu-shan; Yu, Yan-song

    2015-01-01

    Background Stress on the bone surrounding dental micro-implants affects implant success. Purpose To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. Materials and Methods Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. Results The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. Conclusion When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm. PMID:26659581

  10. Influence of abutment design on the success of immediately loaded dental implants: experimental and numerical studies.

    PubMed

    Hasan, I; Röger, B; Heinemann, F; Keilig, L; Bourauel, C

    2012-09-01

    The aim of the present study was to investigate experimentally and numerically the influence of a fine threaded- against a roughened-cervical region of immediately loaded dental implants in combination with straight and 20°-angled abutments on the implant primary stability. A total of 30 implants were inserted in bovine rib-segments, 14 cervically roughened implants and 16 implants with fine cervical threads. Each implant system received two abutments, straight and 20°-angled. Implant displacements and rotations were measured using a biomechanical measurement system. Subsequently, eight samples were selected for geometrical reconstruction and numerical investigation of stress and strain distributions in the bone by means of the finite element method. Experimentally, both implant systems showed similar behaviour with the straight abutments concerning displacements and rotations. However, fine threaded implants showed much less displacement and rotation against roughened implants when angled abutments were considered. Numerically, stresses were within 35-45 MPa in the cortical bone for both implant systems. The strains showed highest values within the spongious bone with the roughened implants connected to angled abutments. The results indicate that implants with fine cervical threads could be recommended in particular with angled abutments. The outcomes of this study are currently confirmed by long-term clinical investigations. Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. Esthetic evaluation of single-tooth implants in the anterior maxilla following autologous bone augmentation.

    PubMed

    Hof, M; Pommer, B; Strbac, G D; Sütö, D; Watzek, G; Zechner, W

    2013-08-01

    Autologous bone augmentation to rebuild compromised alveolar ridge contour prior to implant placement allows for favorable three-dimensional implant positioning to achieve optimum implant esthetics. The aim of the present study was to evaluate peri-implant soft tissue conditions around single-tooth implants following bone grafts in the esthetic zone of the maxilla. Sixty patients underwent autologous bone augmentation of deficient maxillary sites prior to placement of 85 implants in the esthetic zone. In case of multiple implants per patient, one implant was randomly selected. Objective evaluation of 60 single-tooth implants was performed using the Pink-Esthetic-Score (PES) and Papilla Index (PI) and supplemented by subjective patient evaluation, as well as clinical and radiologic examination. Objective ratings of implant esthetics were satisfactory (median PES: 11, median PI: 2) and significantly correlated with high patient satisfaction (mean VAS score: 80%). Both esthetic indices demonstrated respectable levels of inter- as well as intra-observer agreement. Poor implant esthetics (low PES and PI ratings) were significantly associated with increased anatomic crown height, while no influence of horizontal implant-tooth distance could be found. The present investigation indicates that favorable esthetic results may be achieved in the augmented anterior maxilla. However, bony reconstruction of compromised alveolar ridges does not guarantee optimum implant esthetics. © 2011 John Wiley & Sons A/S.

  12. Esthetics of Flapless Single-Tooth Implants in the Anterior Maxilla Using Guided Surgery: Association of Three-Dimensional Accuracy and Pink Esthetic Score.

    PubMed

    Fürhauser, Rudolf; Mailath-Pokorny, Georg; Haas, Robert; Busenlechner, Dieter; Watzek, Georg; Pommer, Bernhard

    2015-10-01

    Flapless implant placement using surgical templates may guarantee predictable and esthetic results provided that preplanned implant positions are transfered precisely into surgical reality. The study aims to investigate the effect of three-dimensional accuracy in guided implant surgery on the esthetic outcome of single-tooth implants in the anterior maxilla. Single-tooth implants for delayed replacement of upper incisors were inserted in 27 patients using stereolithographic templates. Superimposition of postoperative cone beam computed tomography (CBCT) scans allowed assessment of positional inaccuracy at the implant shoulder and apex, as well as angular deviation. Objective evaluation of implant esthetics was performed after a mean follow-up of 2.3 years using the Pink Esthetic Score (PES). Mean deviation between planned and actual implant position was 0.84 mm at the implant shoulder and significantly correlated to average PES of 12 (p = .031). Inaccuracy toward the buccal side was most frequent (70%). Deviations  ≥  0.8  mm resulted in significantly worse implant esthetics (median PES: 9.5, interquartile range [IQR]: 8-11) compared with more accurate implant positions (median PES: 13, IQR: 12-13, p = .039). Positional inaccuracy is low in guided implant surgery, but may however significantly compromise implant esthetics in the anterior maxilla. © 2014 Wiley Periodicals, Inc.

  13. Effect of Healing Time on Bone-Implant Contact of Orthodontic Micro-Implants: A Histologic Study

    PubMed Central

    Ramazanzadeh, Barat Ali; Fatemi, Kazem; Dehghani, Mahboobe; Mohtasham, Nooshin; Jahanbin, Arezoo; Sadeghian, Hamed

    2014-01-01

    Objectives. This study aimed to evaluate the effect of immediate and delayed loading of orthodontic micro-implants on bone-implant contact. Materials and Methods. Sixty four micro-implants were implanted in dog's jaw bone. The micro-implants were divided into loaded and unloaded (control) groups. The control group had two subgroups: four and eight weeks being implanted. The loaded group had two subgroups of immediate loading and delayed (after four weeks healing) loading. Loaded samples were subjected to 200g load for four weeks. After sacrificing the animals micro-implants and surrounding tissues were observed histologically. Bone-implant contact ratios (BIC) were calculated and different groups' results were compared by three-way ANOVA. Results. Mean survival rate was 96.7% in general. Survival rates were 96.7%, 94.4% and 100% for control, immediate and delayed loaded groups, respectively. BIC values were not significantly different in loaded and control groups, immediate and delayed loading groups, and pressure and tension sides. Mandibular micro-implants had significantly higher BIC than maxillary ones in immediate loading, 4-weeks control, and 8-weeks control groups (P = 0.021, P = 0.009, P = 0.003, resp.). Conclusion Immediate or delayed loading of micro-implants in dog did not cause significant difference in Bone-implant contact which could be concluded that healing time had not significant effect on micro-implant stability. PMID:25006463

  14. Surface microstructure of dental implants before and after insertion: an in vitro study by means of scanning probe microscopy.

    PubMed

    Salerno, Marco; Itri, Angelo; Frezzato, Marco; Rebaudi, Alberto

    2015-06-01

    The surface microstructure of dental implants affects osseointegration, which makes their accurate topographic characterization important. We defined a procedure for evaluation of implant topography before (pre-) and after (post-) in vitro implantation test in bovine bone. The apical morphology of ten implants was analyzed in pre- and post-conditions using atomic force microscopy or 3D profilometry. We extracted four topographical parameters (two amplitude, 1 spatial, and 1 hybrid) and assessed the differences by analysis of variance. The implant with coating (Spline Twist MP-1 HA) was damaged. The two implants with highest pre-amplitude parameters (Pitt Easy VTPS, TLR3815) maintained their character on testing. Pitt Easy PURETEX and OT-F1 were the only nondamaged implants whose amplitude parameters increased. The surface area underwent minor changes even when the texture changed (Tri-Vent, Pitt Easy PURETEX, Exp #1). The implants that ranked the lowest in all parameters before implantation were DT4013TI, Tri-Vent, OT-F1, and Exp #2. On testing, DT4013TI showed the highest decrease in values, whereas Tri-Vent showed the highest increase in surface area. All the experimental implants showed similar topographic properties both pre- and post-test. For most implants, no major changes occurred in surface topography on implantation. The procedure applied seems promising to evaluate the degradation of implant surface on insertion.

  15. Association Between Peri-implant Bone Morphology and Marginal Bone Loss: A Retrospective Study on Implant-Supported Mandibular Overdentures.

    PubMed

    Ding, Qian; Zhang, Lei; Geraets, Wil; Wu, Wuqing; Zhou, Yongsheng; Wismeijer, Daniel; Xie, Qiufei

    The present study aimed to explore the association between marginal bone loss and type of peri-implant bony defect determined using a new peri-implant bony defect classification system. A total of 110 patients with implant-supported mandibular overdentures were involved. Clinical information was collected, including gender, age, smoking habit, and the overdenture attachment system used. Peri-implant bony defect types and marginal distances (ie, distance between the marginal bone level and the top of the implant shoulder) of all sites were identified on panoramic radiographs by a single experienced observer. The associations between marginal distance and peri-implant bony defect type, gender, age, smoking habit, attachment system, and time after implantation were investigated using marginal generalized linear models and regression analysis. A total of 83 participants were included in the final sample with a total of 224 implants involving 3,124 implant sites. The mean observation time was 10.7 years. All peri-implant bony defect types except Type 5 (slit-like) were significantly related to marginal distance in all models (P < .01). Smoking and time after implantation were significantly related to marginal distance while gender, age, and the overdenture attachment system used were not. The peri-implant bony defect type, determined using the new classification system, is associated with the extent of marginal bone loss.

  16. Evaluation of the peri-implant bone around parallel-walled dental implants with a condensing thread macrodesign and a self-tapping apex: a 10-year retrospective histological analysis.

    PubMed

    Degidi, Marco; Perrotti, Vittoria; Shibli, Jamil A; Mortellaro, Carmen; Piattelli, Adriano; Iezzi, Giovanna

    2014-05-01

    The long-term high percentages of survival and success of dental implants reported in the literature are related mainly to new, innovative implant and thread designs, and new implant surfaces that allow to obtain very good primary and secondary stability in most anatomical and clinical situations, even in low quality and quantity of bone, promoting a more rapid osseointegration. The aim of this retrospective study was a histological and histomorphometrical evaluation of the bone response around implants with a parallel-wall configuration, condensing thread macrodesign, and self-tapping apex, retrieved from man for different causes. A total of 10 implants were reported in the present study, and these implants had been retrieved after a loading period comprised between a few weeks to about 8 years. Mineralized newly formed bone was found at the interface of all the implants, in direct contact with the implant surface, with no gaps or connective fibrous tissue. This bone adapted very well to the microirregularities of the implant surface. Areas of bone remodeling were present in some regions of the interface, with many reversal lines. High bone-implant contact percentages were found. In conclusion, both the macrostructure and the microstructure of this specific type of implant could be very helpful in the long-term high survival and success implant percentages.

  17. Sound-direction identification with bilateral cochlear implants.

    PubMed

    Neuman, Arlene C; Haravon, Anita; Sislian, Nicole; Waltzman, Susan B

    2007-02-01

    The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. Eight adults who were bilateral users of Nucleus 24 Contour devices participated in the study. All had received implants in both ears in a single surgery. Sound-direction identification was measured in a large classroom by using a nine-loudspeaker array. Localization was tested in three listening conditions (bilateral cochlear implants, left cochlear implant, and right cochlear implant), using two different stimuli (a speech stimulus and pink noise bursts) in a repeated-measures design. Sound-direction identification accuracy was significantly better when using two implants than when using a single implant. The mean root-mean-square error was 29 degrees for the bilateral condition, 54 degrees for the left cochlear implant, and 46.5 degrees for the right cochlear implant condition. Unilateral accuracy was similar for right cochlear implant and left cochlear implant performance. Sound-direction identification performance was similar for speech and pink noise stimuli. The data obtained in this study add to the growing body of evidence that sound-direction identification with bilateral cochlear implants is better than with a single implant. The similarity in localization performance obtained with the speech and pink noise supports the use of either stimulus for measuring sound-direction identification.

  18. Histologic analysis of resorbable blasting media surface implants retrieved from humans: a report of two cases

    PubMed Central

    2016-01-01

    The purpose of this study is to evaluate the degree of osseointegration of resorbable blasting media (RBM) surface implants retrieved from humans. Three implants in the mandibular molar region that were surface-treated with RBM were retrieved from two patients. The implants were used to manufacture specimens in order to measure the bone-implant contact (BIC) ratio. The BIC ratios of the three implants were found to be an average of 69.0%±9.1%. In conclusion, that RBM surface implants are integrated into the host environment with histological significance and the BIC ratio of the RBM surface-treated implant was not significantly different from that of other surface-treated implants. PMID:26904493

  19. Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants

    PubMed Central

    Jain, Anoop; K, Cauvery; Kumar, Pawan; Havale, Raghavendra

    2014-01-01

    An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques. PMID:24959520

  20. Modification of Fixture Mount to be Used as an Impression Coping in Closely Placed Implants.

    PubMed

    Mahoorkar, Sudhindra; Jain, Anoop; K, Cauvery; Kumar, Pawan; Havale, Raghavendra

    2014-04-01

    An implant-level impression is often desired for designing and fabricating an implant-supported fixed restoration. This clinical report describes the use of modified press-fit metal implant fixture mount as an impression coping for making an impression of closely placed implants. The fixture mount is easier to manipulate, time saving and more comfortable for both the clinician and patient because the implant fixture mount is connected to the implant by pressing on instead of screwing. As compared to plastic press fit impression coping, metal fixture mount will not distort when modification of fixture mount are required in convergently or closely placed implants. It has the advantage of both the open-tray and closed-tray implant impression techniques.

  1. Influence of implant rod curvature on sagittal correction of scoliosis deformity.

    PubMed

    Salmingo, Remel Alingalan; Tadano, Shigeru; Abe, Yuichiro; Ito, Manabu

    2014-08-01

    Deformation of in vivo-implanted rods could alter the scoliosis sagittal correction. To our knowledge, no previous authors have investigated the influence of implanted-rod deformation on the sagittal deformity correction during scoliosis surgery. To analyze the changes of the implant rod's angle of curvature during surgery and establish its influence on sagittal correction of scoliosis deformity. A retrospective analysis of the preoperative and postoperative implant rod geometry and angle of curvature was conducted. Twenty adolescent idiopathic scoliosis patients underwent surgery. Average age at the time of operation was 14 years. The preoperative and postoperative implant rod angle of curvature expressed in degrees was obtained for each patient. Two implant rods were attached to the concave and convex side of the spinal deformity. The preoperative implant rod geometry was measured before surgical implantation. The postoperative implant rod geometry after surgery was measured by computed tomography. The implant rod angle of curvature at the sagittal plane was obtained from the implant rod geometry. The angle of curvature between the implant rod extreme ends was measured before implantation and after surgery. The sagittal curvature between the corresponding spinal levels of healthy adolescents obtained by previous studies was compared with the implant rod angle of curvature to evaluate the sagittal curve correction. The difference between the postoperative implant rod angle of curvature and normal spine sagittal curvature of the corresponding instrumented level was used to evaluate over or under correction of the sagittal deformity. The implant rods at the concave side of deformity of all patients were significantly deformed after surgery. The average degree of rod deformation Δθ at the concave and convex sides was 15.8° and 1.6°, respectively. The average preoperative and postoperative implant rod angle of curvature at the concave side was 33.6° and 17.8°, respectively. The average preoperative and postoperative implant rod angle of curvature at the convex side was 25.5° and 23.9°, respectively. A significant relationship was found between the degree of rod deformation and preoperative implant rod angle of curvature (r=0.60, p<.005). The implant rods at the convex side of all patients did not have significant deformation. The results indicate that the postoperative sagittal outcome could be predicted from the initial rod shape. Changes in implant rod angle of curvature may lead to over- or undercorrection of the sagittal curve. Rod deformation at the concave side suggests that corrective forces acting on that side are greater than the convex side. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. Effect of anabolic implants on adrenal cortisol synthesis in feedlot beef cattle implanted early or late in the finishing phase.

    PubMed

    Gifford, C A; Branham, K A; Ellison, J O; Gómez, B I; Lemley, C O; Hart, C G; Krehbiel, C R; Bernhard, B C; Maxwell, C L; Goad, C L; Hallford, D M; Hernandez Gifford, J A

    2015-01-01

    Implantation of anabolic steroids to increase growth rate in beef cattle impacts adrenal glucocorticoid production. The mechanism by which combination androgen and estrogen implants reduce cortisol biosynthesis in heifers is not clear. The objective of this study was to identify whether pituitary or adrenal gene expression and liver enzyme activity may contribute to altered serum cortisol concentrations in heifers receiving a combination implant. On d 0 of a 122-d finishing phase, 187 predominantly Angus heifers (361 kg) approximately 14 months old were randomly assigned to one of three implant groups: (1) non-implanted control, (2) implanted at the beginning of the finishing phase (d 0; early implant) with a combination implant (200mg TBA+20mg E2; Revalor 200®), and (3) implanted during the late stage of the finishing phase (d 56; late implant) with Revalor 200®. At d 56, body weight (BW) was greater (P<0.0001) for the early implanted heifers (456 ± 1.9 kg) compared to 437 and 435 (± 1.8) kg for control and late implanted heifers, respectively. Final BW (d 122) was similar between both implanted groups and heavier than non-implanted controls (P<0.0001). Serum cortisol was similar among groups at d 0 (P=0.86) however, by d 28 heifers receiving the combination implant had reduced (P<0.05) serum cortisol concentrations (31.2 ng/mL) compared to controls (49.4 ng/mL) and late (48.2 ng/mL) groups. On d 84 cortisol was similar (P=0.75) among implanted heifers and was less (P<0.01) than non-implanted heifers. Expression of pituitary and adrenal genes involved in glucocorticoid synthesis was evaluated at d 28/29 or 84/85; however, despite decreased serum cortisol in implanted heifers, no change in mRNA expression was demonstrated. Liver CYP3A enzyme activity at d 28/29 was decreased 59% in early implanted heifers compared to control heifers (P=0.01). Additionally, at d 84/85 AKR1C activity was greatest (P=0.01) in control heifers compared to both implanted groups. Data suggest that components of hypothalamic-pituitary-adrenal axis are influenced by exposure to exogenous hormones and this should be recognized when considering cortisol levels as a marker for stress response. Copyright © 2014 Elsevier Inc. All rights reserved.

  3. Subgingival Microbiome Colonization and Cytokine Production during Early Dental Implant Healing.

    PubMed

    Payne, Jeffrey B; Johnson, Paul G; Kok, Car Reen; Gomes-Neto, João C; Ramer-Tait, Amanda E; Schmid, Marian J; Hutkins, Robert W

    2017-01-01

    Little is known about longitudinal development of the peri-implant subgingival microbiome and cytokine production as a new sulcus forms after dental implant placement. Therefore, the purpose of this observational study was to evaluate simultaneous longitudinal changes in the oral microbiome and cytokine production in the developing peri-implant sulcus compared to control natural teeth. Four and 12 weeks after implant placement and abutment connection, a dental implant and a natural tooth were sampled in 25 patients for subgingival plaque and gingival crevicular fluid (GCF [around teeth] and peri-implant crevicular fluid [PICF] around implants). DNA from plaque samples was extracted and sequenced using Illumina-based 16S rRNA sequencing. GCF and PICF samples were analyzed using a customized Milliplex human cytokine and chemokine magnetic bead panel. Beta diversity analysis revealed that natural teeth and implants had similar subgingival microbiomes, while teeth had greater alpha diversity than implants. At the genus level, however, few differences were noted between teeth and dental implants over 12 weeks. Specifically, Actinomyces and Selenomonas were significantly elevated around teeth versus dental implants at both 4 weeks and 12 weeks, while Corynebacterium and Campylobacter were significantly elevated only at 4 weeks around teeth. The only difference between PICF and GCF biomarkers was significantly elevated granulocyte-macrophage colony-stimulating factor levels around teeth versus dental implants at the 4-week visit. The subgingival microbiome and cytokine production were similar between teeth and implants during early healing, suggesting that these profiles are driven by the patient following dental implant placement and are not determined by anatomical niche. IMPORTANCE Dental implants are a common treatment option offered to patients for tooth replacement. However, little is known regarding initial colonization of the subgingival microbiome and simultaneous longitudinal cytokine production in humans during the early healing phase following implant placement. We report findings from an in vivo study that assessed initial colonization of the subgingival microbiome and concomitant early cytokine production in a newly formed anatomical space, namely, an implant sulcus. This approach may be useful in future interventional studies to influence dental implant success. Our data showed that the subgingival microbiome and cytokine profile were similar for control natural teeth and dental implants at both 4 and 12 weeks after implant placement. These data suggest that these profiles are driven by the patient and not by anatomical location (i.e., tooth versus dental implant).

  4. Survival and tissue maintenance of an implant with a sloped configurated shoulder in the posterior mandible-a prospective multicenter study.

    PubMed

    Schiegnitz, E; Noelken, R; Moergel, M; Berres, M; Wagner, W

    2017-06-01

    Clinical studies evaluating the influence of the implant design on the preservation of peri-implant keratinized mucosa are rare. The aim of this prospective multicenter study was to investigate the survival, and soft and hard tissue maintenance of an implant with a sloped shoulder configuration, when placed in the posterior mandible. In this study, 24 centers participated and 184 patients receiving 238 implants (OsseoSpeed ™ Profile TX implants) were included. Clinical assessments of soft tissue parameters were performed before implant placement, immediately after implant placement, at prosthetic delivery and at 6, 12 and 24 months after implant placement and marginal bone adaptation was examined. After an average time in situ of 28.7 ± 4.7 months (2.4 ± 0.4 years), the survival rate was 99.2%. Analysis of the peri-implant soft tissues during follow-up showed a slight but significant increase in peri-implant keratinized mucosa width after 2 years (P < 0.001). All patients with reduced peri-implant keratinized mucosa width of ≤ 2 mm at postoperative examination (n = 95) showed a pronounced and statistically significant increase in the peri-implant keratinized mucosa width over time (P < 0.001). After a mean follow-up of 20.7 ± 8 months (1.7 ± 0.7 years), mean inter-proximal marginal bone loss was 0.30 ± 0.6 mm, indicating high bone stability around the sloped implant neck. These results indicate that sloped configurated implants have a high survival rate after 2 years in function. The sloped implant shoulder configuration helps to support the hard and soft tissue around the implant neck and supports the regain of a physiological peri-implant keratinized mucosa in patients with compromised peri-implant soft tissue conditions (Clinicaltrials.gov: NCT01400321). © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  5. Implant stability and marginal bone level of microgrooved zirconia dental implants: A 3-month experimental study on dogs.

    PubMed

    Delgado-Ruiz, Rafael Arcesio; Marković, Aleksa; Calvo-Guirado, José Luís; Lazić, Zoran; Piattelli, Adriano; Boticelli, Daniele; Maté-Sánchez, José Eduardo; Negri, Bruno; Ramírez-Fernández, María Piedad; Mišić, Tijana

    2014-05-01

    The modification of implant surfaces could affect mechanical implant stability as well as dynamics and quality of peri-implant bone healing. The aim of this 3-month experimental study in dogs was to investigate implant stability, marginal bone levels and bone tissue response to zirconia dental implants with two laser-micro-grooved intraosseous surfaces in comparison with nongrooved sandblasted zirconia and sandblasted, high-temperature etched titanium implants. Implant surface characterization was performed using optical interferometric profilometty and energy dispersive X-ray spectroscopy. A total of 96 implants (4 mm in diameter and 10 mm in length) were inserted randomly in both sides of the lower jaw of 12 Fox Hound dogs divided into groups of 24 each: the control (titanium), the group A (sandblasted zirconia), the group B (sandolasted zirconia plus microgrooved neck) and the group C (sandblasted zirconia plus all microgrooved). All the implants were immediately loaded. Insertion torque, periotest values, radiographic crestal bone level and removal torque were recorded during the 3-month follow-up. Qualitative scanning electon microscope (SEM) analysis of the bone-implant interfaces of each group was performed. Insertion torque values were higher in the group C and control implants (p < 0.05). Periotest values increased in all the periods in proportion to the extent of microgrooving as follows: the group C > the control > the group B > the group A (p < 0.05). Radiographic measurements showed minimal crestal bone loss at 3 months for microgrooved zirconia implants (groups C and B) and control implants compared with the group A implants (p < 0.05). The removal torque values increased with time for all the groups as follows: the group C > the control > the group B > the group A (p < 0.05). SEM showed that implant surfaces of the groups B and C had an extra bone growth inside the microgrooves that corresponded to the shape and direction of the microgrooves. The addition of microgrooves to the entire intraosseous surface of zirconia dental implants enhances primary and secondary implant stability, promotes bone tissue ingrowth and preserves crestal bone levels.

  6. The Effect of Insertion Torque on the Clinical Outcome of Single Implants: A Randomized Clinical Trial.

    PubMed

    Barone, Antonio; Alfonsi, Fortunato; Derchi, Giacomo; Tonelli, Paolo; Toti, Paolo; Marchionni, Saverio; Covani, Ugo

    2016-06-01

    The insertion torque value has been extensively used as an indicator for implant primary stability, which is considered a determining parameter for the implants success. The primary goal of the present randomized clinical trial was to evaluate and compare the clinical outcome for implants placed with high insertion torque (between 50 Ncm and 100 Ncm) and regular insertion torque (within 50 Ncm) in healed ridges. Partially edentulous patients, missing one or more mandibular or maxillary teeth, having an adequate amount of bone, requiring implant placement, were randomized to receive Blossom CT implants with regular insertion torque (<50 Ncm) or CT implants with high insertion torque (≥50 Ncm). Implants were left to heal submerged for 3 months. Implants were restored with individualized abutments and cemented metal-ceramic crowns. Acquired measurements were: insertion torque values (IT), thickness of buccal bone plate after implant osteotomy preparation (BBT), marginal bone level (MBL), and facial soft tissue level (FST). All patients were followed 12 months after implant placement. One hundred sixteen implants were placed in one hundred sixteen patients and enrolled for the study. Fifty-eight implants were randomly allocated in regular-IT and high-IT groups with a mean insertion torque ranging from 20 Ncm to 50 Ncm and from 50 Ncm to 100 Ncm, respectively. Three implants failed, and another five implants showed at the 12-month evaluation a marginal bone loss (ΔMBL) greater than 1.5 mm, being considered unsuccessful. The findings suggested that implants inserted with high-IT (≥50 Ncm) in healed bone ridges showed more peri-implant bone remodeling and buccal soft tissue recession than implants inserted with a regular-IT (<50 Ncm). Moreover, sites with a thick buccal bone wall (≥1 mm) - after implant osteotomy site preparation - seemed to be less prone to buccal soft tissue recession after 12 months than sites with a thin buccal bone wall (<1 mm). © 2015 Wiley Periodicals, Inc.

  7. Periapical implant lesion: A systematic review

    PubMed Central

    Blaya-Tárraga, Juan-Antonio; Cervera-Ballester, Juan; Peñarrocha-Oltra, David; Peñarrocha-Diago, Miguel

    2017-01-01

    Background The aim of this study was to systematically review the evidence for periapical implant lesion, which makes a patient more susceptible to the periapical lesion, frequency, symptoms, signs (including radiological findings) and possible treatment options. Material and Methods A systematic literature review and analysis of publications included in PubMed, Embase and Cochrane; articles published until March 2016; with a populations, exposures and outcomes (PEO) search strategy was performed, focused on the issue: “In patients with periapical lesion to the implant during the osseointegration, what symptoms, signs, and changes in complementary examination manifested, for according to that stage, be intervened with the appropriate approach?”. The set criteria for inclusion were peer-reviewed articles. Results From a total of 212 papers identified, 36 studies were included in this systematic review, with 15461 implants evaluated and 183 periapical implant lesions. Which 8 papers included more than 5 cases and 28 included equal or less than 5 cases. Analysis of the papers revealed that periapical implant lesion is classified according to evolution stages into acute (non-suppurated and suppurated) and subacute (or suppurated-fistulized). In the acute stage and in the subacute if there is no loss of implant stability, the correct treatment approach is implant periapical surgery. In the subacute stage associated with implant mobility the implant must be removed. Conclusions Evidence on the subject is very limited, there are few studies with small sample, without homogeneity of criteria for diagnosing the disease and without design of scientific evidence. Currently etiology lacks consensus. The early diagnosis of periapical implant periapical lesions during the osseointegration phase and early treatment, will lead to a higher survival rate of implants treated, hence preventing the need for implant extraction. Key words:Apical peri-implantitis, retrograde peri-implantitis, inflammatory peri-implantitis lesion. PMID:29053646

  8. Biomechanical investigation of thread designs and interface conditions of zirconia and titanium dental implants with bone: three-dimensional numeric analysis.

    PubMed

    Fuh, Lih-Jyh; Hsu, Jui-Ting; Huang, Heng-Li; Chen, Michael Y C; Shen, Yen-Wen

    2013-01-01

    Bone stress and interfacial sliding at the bone-implant interface (BII) were analyzed in zirconia and titanium implants with various thread designs and interface conditions (bonded BII and contact BIIs with different frictional coefficients) for both conventional and immediately loaded treatments. A total of 18 finite element models comprising two implant materials (zirconia and titanium), three thread designs (different shapes and pitches), and three interface conditions (bonded and contact BIIs) were analyzed to assess the effects on bone stresses and on sliding at the BII. The material properties of the bone model were anisotropic, and a lateral force of 130 N was applied as the loading condition. In the immediately loaded implant, the stress was highly concentrated at one site of the peri-implant bone. The peak bone stress was more than 20% lower in zirconia implants than in titanium implants for a bonded BII and 14% to 20% lower for a contact BII. The bone stresses did not differ significantly between implants with V-shaped threads and square threads. However, sliding at the BII was more than 25% lower with square-thread implants than with V-shaped-thread implants for titanium implants and 36% lower for zirconia implants. Reducing the thread size and pitch in cortical bone (via two V-shaped threads with different pitches) decreased the bone stress by 13%. Increasing the frictional coefficient reduced sliding at the BII in both zirconia and titanium implants. As an implant material, zirconia can reduce the bone stress in the crestal cortical region. Bone stress and sliding at the BII are heavily dependent on the thread design and the frictional coefficient at the BII of immediately loaded implants.

  9. Effects of implant system, impression technique, and impression material on accuracy of the working cast.

    PubMed

    Wegner, Kerstin; Weskott, Katharina; Zenginel, Martha; Rehmann, Peter; Wöstmann, Bernd

    2013-01-01

    This in vitro study aimed to identify the effects of the implant system, impression technique, and impression material on the transfer accuracy of implant impressions. The null hypothesis tested was that, in vitro and within the parameters of the experiment, the spatial relationship of a working cast to the placement of implants is not related to (1) the implant system, (2) the impression technique, or (3) the impression material. A steel maxilla was used as a reference model. Six implants of two different implant systems (Standard Plus, Straumann; Semados, Bego) were fixed in the reference model. The target variables were: three-dimensional (3D) shift in all directions, implant axis direction, and rotation. The target variables were assessed using a 3D coordinate measuring machine, and the respective deviations of the plaster models from the nominal values of the reference model were calculated. Two different impression techniques (reposition/pickup) and four impression materials (Aquasil Ultra, Flexitime, Impregum Penta, P2 Magnum 360) were investigated. In all, 80 implant impressions for each implant system were taken. Statistical analysis was performed using multivariate analysis of variance. The implant system significantly influenced the transfer accuracy for most spatial dimensions, including the overall 3D shift and implant axis direction. There was no significant difference between the two implant systems with regard to rotation. Multivariate analysis of variance showed a significant effect on transfer accuracy only for the implant system. Within the limits of the present study, it can be concluded that the transfer accuracy of the intraoral implant position on the working cast is far more dependent on the implant system than on the selection of a specific impression technique or material.

  10. Bruxism and dental implant failures: a multilevel mixed effects parametric survival analysis approach.

    PubMed

    Chrcanovic, B R; Kisch, J; Albrektsson, T; Wennerberg, A

    2016-11-01

    Recent studies have suggested that the insertion of dental implants in patients being diagnosed with bruxism negatively affected the implant failure rates. The aim of the present study was to investigate the association between the bruxism and the risk of dental implant failure. This retrospective study is based on 2670 patients who received 10 096 implants at one specialist clinic. Implant- and patient-related data were collected. Descriptive statistics were used to describe the patients and implants. Multilevel mixed effects parametric survival analysis was used to test the association between bruxism and risk of implant failure adjusting for several potential confounders. Criteria from a recent international consensus (Lobbezoo et al., J Oral Rehabil, 40, 2013, 2) and from the International Classification of Sleep Disorders (International classification of sleep disorders, revised: diagnostic and coding manual, American Academy of Sleep Medicine, Chicago, 2014) were used to define and diagnose the condition. The number of implants with information available for all variables totalled 3549, placed in 994 patients, with 179 implants reported as failures. The implant failure rates were 13·0% (24/185) for bruxers and 4·6% (155/3364) for non-bruxers (P < 0·001). The statistical model showed that bruxism was a statistically significantly risk factor to implant failure (HR 3·396; 95% CI 1·314, 8·777; P = 0·012), as well as implant length, implant diameter, implant surface, bone quantity D in relation to quantity A, bone quality 4 in relation to quality 1 (Lekholm and Zarb classification), smoking and the intake of proton pump inhibitors. It is suggested that the bruxism may be associated with an increased risk of dental implant failure. © 2016 John Wiley & Sons Ltd.

  11. Bone integration capability of nanopolymorphic crystalline hydroxyapatite coated on titanium implants

    PubMed Central

    Yamada, Masahiro; Ueno, Takeshi; Tsukimura, Naoki; Ikeda, Takayuki; Nakagawa, Kaori; Hori, Norio; Suzuki, Takeo; Ogawa, Takahiro

    2012-01-01

    The mechanism by which hydroxyapatite (HA)-coated titanium promotes bone–implant integration is largely unknown. Furthermore, refining the fabrication of nano-structured HA to the level applicable to the mass production process for titanium implants is challenging. This study reports successful creation of nanopolymorphic crystalline HA on microroughened titanium surfaces using a combination of flame spray and low-temperature calcination and tests its biological capability to enhance bone–implant integration. Sandblasted microroughened titanium implants and sandblasted + HA-coated titanium implants were subjected to biomechanical and histomorphometric analyses in a rat model. The HA was 55% crystallized and consisted of nanoscale needle-like architectures developed in various diameters, lengths, and orientations, which resulted in a 70% increase in surface area compared to noncoated microroughened surfaces. The HA was free from impurity contaminants, with a calcium/phosphorus ratio of 1.66 being equivalent to that of stoichiometric HA. As compared to microroughened implants, HA-coated implants increased the strength of bone–implant integration consistently at both early and late stages of healing. HA-coated implants showed an increased percentage of bone–implant contact and bone volume within 50 μm proximity of the implant surface, as well as a remarkably reduced percentage of soft tissue intervention between bone and the implant surface. In contrast, bone volume outside the 50 μm border was lower around HA-coated implants. Thus, this study demonstrated that the addition of pure nanopolymorphic crystalline HA to microroughened titanium not only accelerates but also enhances the level of bone–implant integration and identified the specific tissue morphogenesis parameters modulated by HA coating. In particular, the nanocrystalline HA was proven to be drastic in increasing osteoconductivity and inhibiting soft tissue infiltration, but the effect was limited to the immediate microenvironment surrounding the implant. PMID:22359461

  12. Effect of roughened micro-threaded implant neck 
and platform switching on marginal bone loss: 
a multicenter retrospective study with 6-year follow-up.

    PubMed

    Di Stefano, Danilo Alessio; Giacometti, Edoardo; Greco, Gian Battista; Gastaldi, Giorgio; Gherlone, Enrico

    2016-01-01

    The aim of this retrospective study was to evaluate medium-term marginal peri-implant bone loss following placement of root-form implants featuring a micro-threaded rough-surfaced neck and a platform-switched implant-abutment connection. Records were identified of patients treated with such implants over a 3-year period at three Italian dental centers. Patient radiographs were digitized and subjected to computerized analysis of peri-implant bone resorption. Records of 112 patients who received 257 implants were analyzed. Although implant diameters and lengths varied, all had a 0.3-mm platform-switching width and a 2.5-mm high micro-threaded neck. All patients healed uneventfully, and no peri-implant infection, implant mobility, or radiolucency around the implant were detected at any follow-up control. At the 72-month control (average 71 ± 5 months) all implants were successful according to Albrektsson and Zarb's criteria. At implant level, average peri-implant bone resorption was 0.18 ± 0.12 mm at 6 months, 0.22 ± 0.15 mm at 12 months, 0.23 ± 0.16 mm at 24 months, 0.25 ± 0.17 mm at 36 months, 0.26 ± 0.15 mm at 48 months, and stable at subsequent controls, regardless of the implant diameter and length. At patient level, a similar trend was observed, with crestal bone loss stabilizing from 48 months onward. The surface, geometry, and platform-switching features of the implant under investigation allowed effective bone preservation on a medium-term basis.

  13. Evaluation of the Alteration of Occlusal Distribution in Unilateral Free-End and Intermediate Missing Cases.

    PubMed

    Kon, Kazuhiro; Shiota, Makoto; Sakuyama, Aoi; Ozeki, Maho; Kozuma, Wataru; Kawakami, Sawako; Kasugai, Shohei

    2017-02-01

    The present study aimed to evaluate the effect of implant prostheses on the occlusal force and area as well as the distribution of occlusal loading in unilateral free-end and intermediate missing cases. Fourteen healthy subjects (7 free-end missing cases in the first and second molars and 7 intermediate missing cases in the first molar region) were included. Six months after the implant prosthesis was placed, an occlusal evaluation was performed with or without the implant superstructure by using Dental Prescale film and an occluder device. In free-end missing cases, the total occlusal force and area, implant-side occlusal force and area, and implant-side occlusal force and area of the residual natural teeth were significantly affected by the implant prostheses. In intermediate missing cases, the implant-side occlusal force of the residual natural teeth was significantly affected by the implant prostheses. In free-end missing cases, the proportions of implant-side occlusal force, non-implant-side occlusal force, and implant-side occlusal force of the residual natural teeth relative to the total occlusal force were significantly affected by the implant prostheses. In the intermediate missing cases, the proportion of the implant-side occlusal force of the residual natural teeth relative to the total occlusal force was significantly affected by the implant prostheses. The proportion of the occlusal area was also significantly affected. In free-end missing cases, implant prostheses significantly increased the occlusal force and area, which resulted in the proper occlusal distribution. In intermediate missing cases, an implant prosthesis may only improve the same-side occlusal loading of the natural teeth.

  14. Evaluation of bone response to titanium-coated polymethyl methacrylate resin (PMMA) implants by X-ray tomography.

    PubMed

    Shalabi, Manal M; Wolke, Johannes G C; Cuijpers, Vincent M J I; Jansen, John A

    2007-10-01

    High-resolution three-dimensional data about the bone response to oral implants can be obtained by using microfocus computer tomography. However, a disadvantage is that metallic implants cause streaking artifacts due to scattering of X-rays, which prevents an accurate evaluation of the interfacial bone-to-implant contact. It has been suggested that the use of thin titanium coatings deposited on polymeric implants can offer an alternative option for analyzing bone contact using micro-CT imaging. Consequently, the aim of the current study was to investigate bone behavior to titanium-coated polymethylmethacrylate (PMMA) implants by micro-CT and histological evaluation. For the experiment titanium-coated PMMA implants were used. The implants had a machined threaded appearance and were provided with a 400-500 nm thick titanium coating. The implants were inserted in the right or left tibia of 10 goats. After an implantation period of 12 weeks the implants were retrieved and prepared for micro-computer tomography (microCT), light microscopy, and X-ray microanalysis. The micro-CT showed that the screw-threads and typical implant configuration were well maintained through the installation procedure. Overall, histological responses showed that the titanium-coated implants were well tolerated and caused no atypical tissue response. In addition, the bone was seen in direct contact with the titanium-coated layer. The X-ray microanalysis results confirmed the light microscopical data. In conclusion, the obtained results proof the final use of titanium-coated PMMA implants for evaluation of the bone-implant response using microCT. However, this study also confirms that for a proper analysis of the bone-implant interface the additional use of microscopical techniques is still required.

  15. Effect of Implant Diameter and Ridge Dimension on Stress Distribution in Mandibular First Molar Sites-A Photoelastic Study.

    PubMed

    Termeie, Deborah; Klokkevold, Perry R; Caputo, Angelo A

    2015-10-01

    The long-term clinical success of a dental implant is dependent upon maintaining sufficient osseointegration to resist forces of occlusion. The purpose of this study was to investigate the effect of implant diameter on stress distribution around screw-type dental implants in mandibular first molar sites using photoelastic models. The design included models with different buccal-lingual dimension. Twelve composite photoelastic models were assembled using 2 different resins to simulate trabecular and cortical bone. Half of the models were fabricated with average dimensions for ridge width and the other half with narrower buccal-lingual dimensions. One internal connection implant (13 mm length) with either a standard (4 mm), wide (5 mm), or narrow (3.3 mm) diameter was embedded in the first molar position of each photoelastic model. Half the implants were tapered and the other half were straight. Full gold crowns in the shape of a mandibular first molar were fabricated and attached to the implants. Vertical and angled loads of 15 and 30 pounds were applied to specific points on the crown. Wide-diameter implants produced the least stress in all ridges while narrow-diameter implants generated the highest stress, especially in narrow ridges. It may be that the volume and quality of bone surrounding implants influences stress distribution with a greater ratio of cortical to trabecular bone, thus providing better support. Models with wide-diameter implants loaded axially had a more symmetrical stress distribution compared to standard and narrow diameter implants. A more asymmetrical stress pattern developed along the entire implant length with angled loads. Implant diameter and ridge width had considerable influence on stress distribution. Narrow-diameter implants produced more stress than wide diameter implants in all conditions tested.

  16. Sino-implant (II) - a levonorgestrel-releasing two-rod implant: systematic review of the randomized controlled trials

    PubMed Central

    Steiner, Markus J.; Lopez, Laureen M.; Grimes, David A.; Cheng, Linan; Shelton, Jim; Trussell, James; Farley, Timothy M.M.; Dorflinger, Laneta

    2013-01-01

    Background Sino-implant (II) is a subdermal contraceptive implant manufactured in China. This two-rod levonorgestrel-releasing implant has the same amount of active ingredient (150 mg levonorgestrel) and mechanism of action as the widely available contraceptive implant Jadelle. We examined randomized controlled trials of Sino-implant (II) for effectiveness and side effects. Study design We searched electronic databases for studies of Sino-implant (II), and then restricted our review to randomized controlled trials. The primary outcome of this review was pregnancy. Results Four randomized trials with a total of 15,943 women assigned to Sino-implant (II) had first-year probabilities of pregnancy ranging from 0.0% to 0.1%. Cumulative probabilities of pregnancy during the four years of the product's approved duration of use were 0.9% and 1.06% in the two trials that presented date for four-year use. Five-year cumulative probabilities of pregnancy ranged from 0.7% to 2.1%. In one trial, the cumulative probability of pregnancy more than doubled during the fifth year (from 0.9% to 2.1%), which may be why the implant is approved for four years of use in China. Five-year cumulative probabilities of discontinuation due to menstrual problems ranged from 12.5% to 15.5% for Sino-implant (II). Conclusions Sino-implant (II) is one of the most effective contraceptives available today. These available clinical data, combined with independent laboratory testing, and the knowledge that 7 million women have used this method since 1994, support the safety and effectiveness of Sino-implant (II). The lower cost of Sino-implant (II) compared with other subdermal implants could improve access to implants in resource-constrained settings. PMID:20159174

  17. Effect of radial head implant shape on joint contact area and location during static loading.

    PubMed

    Shannon, Hannah L; Deluce, Simon R; Lalone, Emily A; Willing, Ryan; King, Graham J W; Johnson, James A

    2015-04-01

    To examine the effect of implant shape on radiocapitellar joint contact area and location in vitro. We used 8 fresh-frozen cadaveric upper extremities. An elbow loading simulator examined joint contact in pronation, neutral rotation, and supination with the elbow at 90° flexion. Muscle tendons were attached to pneumatic actuators to allow for computer-controlled loading to achieve the desired forearm rotation. We performed testing with the native radial head, an axisymmetric implant, a reverse-engineered patient-specific implant, and a population-based quasi-anatomic implant. Implants were inserted using computer navigation. Contact area and location were quantified using a casting technique. We found no significant difference between contact locations for the native radial head and the 3 implants. All of the implants had a contact area lower than the native radial head; however, only the axisymmetric implant was significantly different. There was no significant difference in contact area between implant shapes. The similar contact areas and locations of the 3 implant designs suggest that the shape of the implant may not be important with respect to radiocapitellar joint contact mechanics when placed optimally using computer navigation. Further work is needed to explore the sensitivity of radial head implant malpositioning on articular contact. The lower contact area of the radial head implants relative to the native radial head is similar to previous benchtop studies and is likely the result of the greater stiffness of the implant. Radial head implant shape does not appear to have a pronounced influence on articular contact, and both axisymmetric and anatomic metal designs result in elevated cartilage stress relative to the intact state. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  18. Current use of implantable electrical devices in Sweden: data from the Swedish pacemaker and implantable cardioverter-defibrillator registry.

    PubMed

    Gadler, Fredrik; Valzania, Cinzia; Linde, Cecilia

    2015-01-01

    The National Swedish Pacemaker and Implantable Cardioverter-Defibrillator (ICD) Registry collects prospective data on all pacemaker and ICD implants in Sweden. We aimed to report the 2012 findings of the Registry concerning electrical devices implantation rates and changes over time, 1 year complications, long-term device longevity and patient survival. Forty-four Swedish implanting centres continuously contribute implantation of pacemakers and ICDs to the Registry by direct data entry on a specific website. Clinical and technical information on 2012 first implants and postoperative complications were analysed and compared with previous years. Patient survival data were obtained from the Swedish population register database. In 2012, the mean pacemaker and ICD first implantation rates were 697 and 136 per million inhabitants, respectively. The number of cardiac resynchronization therapy (CRT) first implantations/million capita was 41 (CRT pacemakers) and 55 (CRT defibrillators), with only a slight increase in CRT-ICD rate compared with 2011. Most device implantations were performed in men. Complication rates for pacemaker and ICD procedures were 5.3 and 10.1% at 1 year, respectively. Device and lead longevity differed among manufacturers. Pacemaker patients were older at the time of first implant and had generally worse survival rate than ICD patients (63 vs. 82% after 5 years). Pacemaker and ICD implantation rates seem to have reached a level phase in Sweden. Implantable cardioverter-defibrillator and CRT implantation rates are very low and do not reflect guideline indications. Gender differences in CRT and ICD implantations are pronounced. Device and patient survival rates are variable, and should be considered when deciding device type. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2014. For permissions please email: journals.permissions@oup.com.

  19. Long-term evaluation of Astra Tech and Brånemark implants in patients treated with full-arch bridges. Results after 12-15 years.

    PubMed

    Ravald, Nils; Dahlgren, Simon; Teiwik, Anders; Gröndahl, Kerstin

    2013-10-01

    To study the long-term outcome of implant survival rate, soft and hard tissue conditions and prosthetic status in a group of individuals treated with either Astra Tech TiOblast or Brånemark turned implants supporting a full-arch bridge. Edentulous patients treated with either Astra Tech TiOblast surface or Brånemark turned implants were recalled for examination after 12-15 years. Out of initially 66 patients 46 were available for examination. Intra-oral radiographs were taken for bone level assessments. Clinical prosthetic conditions, number of surviving implants, implant stability, plaque scores, probing pocket depths, bleeding and pus after probing were recorded. Analyses of bone level changes during the total observation period were performed. Three patients in the Astra Tech group lost totally eight implants and five patients in the Brånemark group lost 10 implants during the total observation period. No statistically significant difference in implant loss or bone level change was found. Sixteen per cent of Astra Tech and 29% of Brånemark patients showed at least one implant with ≥2 mm bone loss after the first year in function. The corresponding prevalence on implant level was 6% and 5% respectively. No significant differences were found between the other examined variables. Two patients showed prosthetic complications of the supra construction in need of repair. Seven bridges had minor ceramic chippings. Treatment with Astra Tech TiOblast implants and Brånemark turned implants supporting full-arch bridges showed generally good clinical results with low numbers of implants with marginal bone loss indicative of peri-implantitis. No significant differences were found between the implant systems after 12-15 years in function. © 2012 John Wiley & Sons A/S.

  20. Comparison of retention and stability of implant-retained overdentures based upon implant number and distribution.

    PubMed

    Scherer, Michael D; McGlumphy, Edwin A; Seghi, Robert R; Campagni, Wayne V

    2013-01-01

    The purpose of this investigation was to evaluate the effects of number and distribution of implants upon in vitro dislodging forces to a simulated implant-supported overdenture and to examine differences between several different attachment systems. An experiment was undertaken utilizing a model simulating a mandibular edentulous ridge with dental implants in positions on the model approximating tooth positions in the natural dentition. A cobalt-chromium-cast testing framework was used to measure the peak load required to disconnect an attachment. Four different types of commercially available attachments were used in various positions on the model in sequence to evaluate the effects of retention and stability of overdentures based on implant number and distribution: (1) ERA, (2) O-Ring, (3) Locator, and (4) Ball. For each group, 10 measurements were made of peak dislodging forces. Means were calculated and differences among the systems, directions, and groups were identified using a repeated measured analysis of variance (α = .05). The interactions between the attachment system, direction of force, and implant number and distribution were statistically significant. Vertical dislodging forces of the simulated overdenture prosthesis increased with additional widely spaced implants. Oblique dislodging forces of the simulated prosthesis increased with additional widely spaced implants except in the two-implant model with all attachments, and in the four-implant groups with Locator attachments. Anteroposterior dislodging forces of a simulated overdenture prosthesis increased with additional widely spaced implants except in the four-implant groups with Ball and Locator attachments. Ball attachments reported the highest levels of retention and stability followed by Locator, O-Ring, and ERA. Within the limitations of this study, retention and stability of an implant overdenture prosthesis are significantly affected by implant number, implant distribution, and abutment type.

  1. How to treat two adjacent missing teeth with dental implants. A systematic review on single implant-supported two-unit cantilever FDP's and results of a 5-year prospective comparative study in the aesthetic zone.

    PubMed

    Van Nimwegen, W G; Raghoebar, G M; Tymstra, N; Vissink, A; Meijer, H J A

    2017-06-01

    To conduct a systematic review on the clinical outcome of single implant-supported two-unit cantilever FDP's and to conduct a 5-year prospective comparative pilot study of patients with a missing central and lateral upper incisor treated with either a single implant-supported two-unit cantilever FDP or two implants with solitary implant crowns in the aesthetic zone. Medline, Embase and the Cochrane Central Register of Controlled Trials were searched (last search 1 August 2016) for eligible studies. In the comparative pilot study, an implant-cantilever group of five patients with a single implant-supported two-unit cantilever FDP (NobelReplace Groovy Regular Platform) was compared with an implant-implant group of five patients with two adjacent single implant-supported crowns (NobelReplace Groovy Regular Platform) in the aesthetic zone. Implant survival, marginal bone level (MBL) changes, pocket probing depth, papilla index and patient satisfaction were assessed during a 5-year follow-up period. Five of 276 articles were considered eligible for data extraction. Implant survival ranged from 96·6% to 100%. Marginal bone level changes were higher in the anterior region than in the posterior region. Technical complications occurred more often in the posterior than anterior region. In the 5-year comparative pilot study, no clinically significant differences in hard and soft peri-implant tissue levels occurred between both groups. Single implant-supported two-unit cantilever FDP's can be a viable alternative to the placement of two adjacent single implant crowns in the aesthetic zone. Due to technical complications, placement of two-unit cantilever crowns in the posterior region can be considered unwise. © 2017 John Wiley & Sons Ltd.

  2. Prevalence of Dental Implants and Evaluation of Peri-implant Bone Levels in Patients Presenting to a Dental School: A Radiographic Cross-Sectional 2-Year Study.

    PubMed

    Alkan, Eylem Ayhan; Mau, Lian Ping; Schoolfield, John; Guest, Gary F; Cochran, David L

    To evaluate the number of patients with dental implants who present to a dental school clinic for screening and to report the prevalence of peri-implant bone level change detected on digital panoramic radiographs of those subjects. Patient screening files for 9,422 patients over a 2-year period were examined to see how many patients presented with dental implants. Those patients with at least one implant were further evaluated by measuring the bone level on the mesial and distal sides of the implant using the screening radiograph. A total of 187 patients (2%) had at least one implant. In regard to implants, 423 were examined and 146 (33%) had no detectable bone loss defined as bone level below the top of the implant. When thresholds of bone loss were evaluated, 109 implants (25%) had ≥ 2 mm of bone loss on either the mesial or distal sides or both. The median bone loss was 1.74 mm for the 277 implants with detectable bone loss and 2.97 mm for the 109 implants that had ≥ 2 mm bone loss. Interestingly, patients who were ≥ 70 years of age had significantly (P = .03) more bone loss in the mandible compared with the maxilla, while patients who were 60 to 69 years of age had significantly greater loss in the maxilla. These data reveal that for patients presenting to the dental school for a screening over a 2-year period, 1.98% had one or more dental implants. Furthermore, those patients with implants had a minimum amount of bone loss as measured from the top of the implant.

  3. Dental implants in medically complex patients-a retrospective study.

    PubMed

    Manor, Yifat; Simon, Roy; Haim, Doron; Garfunkel, Adi; Moses, Ofer

    2017-03-01

    Dental implant insertion for oral rehabilitation is a worldwide procedure for healthy and medically compromised patients. The impact of systemic disease risks on the outcome of implant therapy is unclear, since there are few if any published randomized controlled trials (RCTs). The objective of this study is to investigate the rate of complications and failures following dental implantation in medically compromised patients in order to elucidate risk factors and prevent them. A retrospective cohort study was conducted from patient files treated with dental implantation between the years 2008-2014. The study group consisted of medically complex patients while the control group consisted of healthy patients. Preoperative, intraoperative, and post operative clinical details were retrieved from patients' files. The survival rate and the success rate of the dental implants were evaluated clinically and radiographically. A total of 204 patients (1003 dental implants) were included in the research, in the study group, 93 patients with 528 dental implants and in the control group, 111 patients with 475 dental implants. No significant differences were found between the groups regarding implant failures or complications. The failure rate of dental implants among the patients was 11.8 % in the study group and 16.2 % in the control group (P = 0.04). It was found that patients with a higher number of implants (mean 6.8) had failures compared with patients with a lower number of implants (mean 4.2) regardless of their health status (P < 0.01). We found a similar rate of failure and complications of dental implantation in medically complex patients and in healthy patients. Medically complex patients can undergo dental implantation. There are similar rates of complications and failures of dental implants in medically complex patients and in healthy patients.

  4. A study on setting of the fatigue limit of temporary dental implants.

    PubMed

    Kim, M H; Cho, E J; Lee, J W; Kim, E K; Yoo, S H; Park, C W

    2017-07-01

    A temporary dental implant is a medical device which is temporarily used to support a prosthesis such as an artificial tooth used for restoring patient's masticatory function during implant treatment. It is implanted in the oral cavity to substitute for the role of tooth. Due to the aging and westernization of current Korean society, the number of tooth extraction and implantation procedures is increasing, leading to an increase in the use and development of temporary dental implants. Because an implant performs a masticatory function in place of a tooth, a dynamic load is repeatedly put on the implant. Thus, the fatigue of implants is reported to be the most common causes of the fracture thereof. According to the investigation and analysis of the current domestic and international standards, the standard for fatigue of implant fixtures is not separately specified. Although a test method for measuring the fatigue is suggested in an ISO standard, it is a standard for permanent dental implants. Most of the test standards for Korean manufacturers and importers apply 250 N or more based on the guidance for the safety and performance evaluation of dental implants. Therefore, this study is intended to figure out the fatigue standard which can be applied to temporary dental implants when measuring the fatigue according to the test method suggested in the permanent dental implant standard. The results determined that suitable fatigue standards of temporary dental implants should be provided by each manufacturer rather than applying 250 N. This study will be useful for the establishment of the fatigue standards and fatigue test methods of the manufacturers and importers of temporary dental implants.

  5. Clinical retrospective study of self-reported penicillin allergy on dental implant failures and infections.

    PubMed

    French, David; Noroozi, Mehdi; Shariati, Batoul; Larjava, Hannu

    2016-01-01

    The aim of this retrospective study was to investigate whether self-reported allergy to penicillin may contribute to a higher rate of postsurgical infection and implant failure. This retrospective, non-interventional, open cohort study reports on implant survival and infection complications of 5,576 implants placed in private practice by one periodontist, and includes 4,132 implants that were followed for at least 1 year. Logistic regression was applied to examine the relationship between self-reported allergy to penicillin and implant survival, while controlling for potential confounders such as smoking, implant site, bone augmentation, loading protocol, immediate implantation, and bone level at baseline. The cumulative survival rate (CSR) was calculated according to the life table method and the Cox proportional hazard model was fitted to data. Out of 5,106 implants placed in patients taking penicillin it was found that 0.8% failed, while 2.1% failed of the 470 implants placed for patients with self-reported allergy to penicillin (P = .002). Odds of failure for implants placed in penicillin-allergic patients were 3.1 times higher than in non-allergic patients. For immediate implant placement, penicillin-allergic patients had a failure rate 10-times higher than the non-allergic cohort. Timing of implant failure occurring within 6 months following implantation was 80% in the penicillin-allergic group versus 54% in the non-allergic group. From the 48 implant sites showing postoperative infection: penicillin-allergic patients had an infection rate of 3.4% (n = 16/470) versus 0.6% in the non-allergic group (n = 32/5,106) (P < .05). Self-reported penicillin allergy was associated with a higher rate of infection, and primarily affected early implant failure.

  6. Nanostructured severe plastic deformation processed titanium for orthodontic mini-implants.

    PubMed

    Serra, Glaucio; Morais, Liliane; Elias, Carlos Nelson; Semenova, Irina P; Valiev, Ruslan; Salimgareeva, Gulnaz; Pithon, Matheus; Lacerda, Rogério

    2013-10-01

    Titanium mini-implants have been successfully used as anchorage devices in Orthodontics. Commercially pure titanium (cpTi) was recently replaced by Ti-6Al-4V alloy as the mini-implant material base due to the higher strength properties of the alloy. However, the lower corrosion resistance and the lower biocompatibility have been lowering the success rate of Ti-6Al-4V mini-implants. Nanostructured titanium (nTi) is commercially pure titanium that was nanostructured by a specific technique of severe plastic deformation. It is bioinert, does not contain potentially toxic or allergic additives, and has higher specific strength properties than any other titanium applied in medical implants. The higher strength properties associated to the higher biocompatibility make nTi potentially useful for orthodontic mini-implant applications, theoretically overcoming cpTi and Ti-6Al-4V mini-implants. The purposes of the this work were to process nTi, to mechanically compare cpTi, Ti-6Al-4V, and nTi mini-implants by torque test, and to evaluate both the surface morphology and the fracture surface characteristics of them by SEM. Torque test results showed significant increase in the maximum torque resistance of nTi mini-implants when compared to cpTi mini-implants, and no statistical difference between Ti-6Al-4V and nTi mini-implants. SEM analysis demonstrated smooth surface morphology and transgranular fracture aspect for nTi mini-implants. Since nanostructured titanium mini-implants have mechanical properties comparable to titanium alloy mini-implants, and biocompatibility comparable to commercially pure titanium mini-implants, it is suggestive that nanostructured titanium can replace Ti-6Al-4V alloy as the material base for mini-implants. Copyright © 2013 Elsevier B.V. All rights reserved.

  7. Peri-implant bone length changes and survival rates of implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height.

    PubMed

    Kim, Hae-Young; Yang, Jin-Yong; Chung, Bo-Yoon; Kim, Jeong Chan; Yeo, In-Sung

    2013-04-01

    The aim of this study was to measure the peri-implant bone length surrounding implants that penetrate the sinus membrane at the posterior maxilla and to evaluate the survival rate of these implants. Treatment records and orthopantomographs of 39 patients were reviewed and analyzed. The patients had partial edentulism at the posterior maxilla and limited vertical bone height below the maxillary sinus. Implants were inserted into the posterior maxilla, penetrating the sinus membrane. Four months after implant insertion, provisional resin restorations were temporarily cemented to the abutments and used for one month. Then, a final impression was taken at the abutment level, and final cement-retained restorations were delivered with mutually protected occlusion. The complications from the implant surgery were examined, the number of failed implants was counted, and the survival rate was calculated. The peri-implant bone lengths were measured using radiographs. The changes in initial and final peri-implant bone lengths were statistically analyzed. Nasal bleeding occurred after implant surgery in three patients. No other complications were found. There were no failures of the investigated implants, resulting in a survival rate of 100%. Significantly more bone gain around the implants (estimated difference=-0.6 mm, P=0.025) occurred when the initial residual bone height was less than 5 mm compared to the >5 mm groups. No significant change in peri-implant bone length was detected when the initial residual bone height was 5 mm or larger. This study suggests that implants penetrating the sinus membrane at the posterior maxilla in patients with limited vertical bone height may be safe and functional.

  8. Long-term outcomes of oral rehabilitation with dental implants in HIV-positive patients: A retrospective case series

    PubMed Central

    Gay-Escoda, Cosme; Pérez-Álvarez, Débora; Camps-Font, Octavi

    2016-01-01

    Background The existing information on oral rehabilitations with dental implants in VIH-positive patients is scarce and of poor quality. Moreover, no long-term follow-up studies are available. Hence, the aims of this study were to describe the long-term survival and success rates of dental implants in a group of HIV-positive patients and to identify the most common postoperative complications, including peri-implant diseases. Material and Methods A retrospective case series of HIV-positive subjects treated with dental implants at the School of Dentistry of the University of Barcelona (Spain) was studied. Several clinical parameters were registered, including CD4 cell count, viral load and surgical complications. Additionally, the patients were assessed for implant survival and success rates and for the prevalence of peri-implant diseases. A descriptive statistical analysis of the data was performed. Results Nine participants (57 implants) were included. The patients’ median age was 42 years (IQR=13.5 years). The implant survival and success rates were 98.3% and 68.4%, respectively, with a mean follow-up of 77.5 months (SD=16.1 months). The patient-based prevalence of peri-implant mucositis and peri-implantitis were 22.2% and 44.4% respectively at the last appointment. Patients that attended regular periodontal maintenance visits had significantly less mean bone loss than non-compliant patients (1.3 mm and 3.9 mm respectively). Conclusions Oral rehabilitation with dental implants in HIV-positive patients seems to provide satisfactory results. In order to reduce the considerably high prevalence of peri-implant diseases, strict maintenance programmes must be implemented. Key words:HIV infection, dental implants, oral implantology, complications, peri-implantitis, peri-implant diseases. PMID:26946205

  9. The impact of the use of different types of gloves and bare hands for preparation of clean surgical instruments.

    PubMed

    Bruna, Camila Quartim de Moraes; Souza, Rafael Queiroz de; Massaia, Irineu Francisco Silva; Cruz, Áurea Silveira; Graziano, Kazuko Uchikawa

    2016-10-10

    to determine if there are differences on the safety of the preparation of clean surgical instruments using different types of gloves and bare hands and evaluate the microbiological load of these preparations without gloves. laboratory procedure with a pragmatic approach, in which the samples were handled with different types of gloves and bare hands. In addition, cytotoxicity assays were carried out by means of the agar diffusion method. Further samples were subjected to microbiological analysis after being handled without gloves. none of the samples showed cytotoxic effect. All microbiological cultures showed growth of microorganisms, but no microorganism has been recovered after autoclaving. there were no differences in the cytotoxic responses regarding the use of different types of gloves and bare hands in the handling of clean surgical instruments, which could entail iatrogenic risk. It is noteworthy that the use of gloves involves increase in the costs of process and waste generation, and the potential allergenic risk to latex. determinar se existe diferenças na segurança do preparo de instrumentais cirúrgicos relacionada ao uso de distintos tipos de luvas e das mãos nuas no preparo, e avaliar a carga microbiológica destes preparados sem luvas. experimento laboratorial com abordagem pragmática, onde amostras foram manipuladas com diferentes tipos de luvas e com as mãos nuas, elaborado teste de citotoxicidade por meio da difusão em ágar. Outras Amostras sofreram análise microbiológica após serem manipuladas sem luvas. nenhuma das amostras apresentou efeito citotóxico. Todas as culturas microbiológicas apresentaram crescimento de microrganismos, embora nenhum microrganismo tenha sido recuperado após a autoclavação. não houve diferenças nas respostas citotóxicas relacionadas ao uso de diferentes tipos de luvas e das mãos nuas na manipulação do instrumental cirúrgico limpo que sinalizasse risco de iatrogenia. Ressalta-se que o uso de luvas implica em aumento dos custos do processo e da geração de resíduos, além do potencial risco alergênico ao látex. determinar si existen diferencias en la seguridad de la preparación del instrumental quirúrgico relacionadas con el uso de diferentes tipos de guantes y de las manos desnudas y evaluar la carga microbiológica de estos preparados sin guantes. experimento de laboratorio con enfoque pragmático, en el que las muestras fueron manejadas con diferentes tipos de guantes y las manos desnudas. Además, un ensayo de citotoxicidad se llevó a cabo mediante el método de difusión en agar. Otras muestras fueron sometidas a análisis microbiológico después de haber sido manipuladas sin guantes. ninguna de las muestras presentó efecto citotóxico. Todos los cultivos microbiológicos mostraron crecimiento de microorganismos, pero ningún microorganismo ha sido recuperado después de la esterilización en autoclave. no hubo diferencias en las respuestas citotóxicas con respecto al uso de diferentes tipos de guantes y de las manos desnudas en el manejo del instrumental quirúrgico limpio, lo que podría conllevar riesgo de yatrogenia. Es de destacar que el uso de guantes implica un aumento de los costos del proceso y la generación de residuos, además del potencial riesgo alergénico al látex.

  10. Representative marketing-oriented study on implants in the Austrian population. II. Implant acceptance, patient-perceived cost and patient satisfaction.

    PubMed

    Tepper, Gabor; Haas, Robert; Mailath, Georg; Teller, Christoph; Bernhart, Thomas; Monov, Gabriel; Watzek, Georg

    2003-10-01

    Oral implantology is an established subspecialty of restorative dental and oral surgery. While an extensive body of evidence on the fundamentals of osseointegration and associated factors has been published, marketing-oriented analyses based on representative public opinion polls of implant acceptance, patient-perceived cost and patient satisfaction are scarce. In this study, an attempt was made to address these points by questioning a representative sample of 1000 adults in the household setting. The interviewees were presented with 14 questions. Of those familiar with implants as one of the treatment alternatives, 61% reported they would accept implants if the need arose. Implant acceptance was highest among males and interviewees below the age of 30 years. The interest in implants increased with increasing family incomes. Four percent of those questioned already had implants. Twenty-five percent knew someone who had undergone implant treatment. All those questioned found implant-supported rehabilitation to be very expensive. Many of them blamed the dentists for the high cost. One detail was particularly evident: satisfaction among implanted patients was clearly higher than satisfaction rates perceived by them from what they were told about implants by others. First-hand experiences with implants proved to be less biased than reported second-hand information.

  11. Reliability of implant placement after virtual planning of implant positions using cone beam CT data and surgical (guide) templates.

    PubMed

    Nickenig, Hans-Joachim; Eitner, Stephan

    2007-01-01

    We assessed the reliability of implant placement after virtual planning of implant positions using cone-beam CT data and surgical guide templates. A total of 102 patients (250 implants, 55.4% mandibular; mean patient age, 40.4 years) who had undergone implant treatment therapy in an armed forces dental clinic (Cologne, Germany) between July 1, 2005 and December 1, 2005. They were treated with a system that allows transfer of virtual planning to surgical guide templates. Only in eight cases the surgical guides were not used because a delayed implant placement was necessary. In four posterior mandibular cases, handling was limited because of reduced interocclusal distance, requiring 50% shortening of the drill guides. The predictability of implant size was high: only one implant was changed to a smaller diameter (because of insufficient bone). In all cases, critical anatomical structures were protected and no complications were detected in postoperative panoramic radiographs. In 58.1% (147) of the 250 implants, a flapless surgery plan was realized. Implant placement after virtual planning of implant positions using cone beam CT data and surgical templates can be reliable for preoperative assessment of implant size, position, and anatomical complications. It is also indicative of cases amenable to flapless surgery.

  12. Imunohistological aspects of the tissue around dental implants

    NASA Astrophysics Data System (ADS)

    Nimigean, Victor; Nimigean, Vanda R.; Sǎlǎvǎstru, Dan I.; Moraru, Simona; BuÅ£incu, Lavinia; Ivaşcu, Roxana V.; Poll, Alexandru

    2016-03-01

    Objectives: study of soft and hard tissues around implants. Material and methods: For the immunohistochemical and histological study of the implant/soft tissue interface, we examined pieces of peri-implant mucosa harvested from 35 patients. The implant/bone interface was assessed using histologic and histomorphometric examination of hard tissues around unloaded, early loaded or delayed loaded dental implants with pre-established design, with a sandblasted and acid-etched surface, placed both in extraction sockets, or after bone healing following tooth removal. This study was performed on 9 common race dogs. Results: The histological study of the implant/soft tissue interface showed regenerative modifications and moderate chronic subepithelial inflammatory reactions. Immunohistochemical evaluation of the soft tissue biopsies revealed the presence of specific immunocompetent cells and proteins of the matrix metalloproteinase (MMP) expression. Bone-implants contacts were more obvious in the apical half of the implants and at the edges of the threads, than between them. A mature, lamelliform bone containing lacunae with osteocytes and lack of connective tissue were noticed around implants that were late placed and loaded. The new-formed bone was also abundant in the crestal zone, not only in the apical part of the implants. Conclusions: A thorough understanding of the microstructure of dental implant/soft and hard tissue interface will improve the longevity of osseointegrated implants.

  13. The efficacy of short (6 mm) dental implants with a novel thread design.

    PubMed

    Bechara, Soheil; Nimčenko, Tatjana; Kubilius, Ričardas

    2017-01-01

    To assess efficacy of short (6 mm) implants with a novel macrostructure and thread design placed in a compromised bone situations of edentulous posterior regions of maxilla (3-4 mm of bone height under sinus floor) as compared to results of clinical situations treated with simultaneous maxillary sinus grafting and placement of long (≥10 mm) implants of the same company. Clinical cases of conducted clinical study. Patients with compromised bone height in edentulous posterior regions of maxilla were randomly divided into two groups. Short (6mm length) implant treatment conducted in the test group and simultaneous sinus lift with standard length implant placement treatment in the control group. In general implant stability quotient (ISQ) and marginal bone level (MBL) changes values in both groups were comparable. However, significant negative correlation was found between implant's diameter and MBL changes. Implant's length has little if none impact on initial implant anchorage, especially in greatly compromised residual bone situations. Results have confirmed that implant initial stability mainly depends on implant's macro-design and further its development on implant's micro-design: namely, implant diameter rather than length, tapered shape and improved thread design determines primarily acquired mechanical anchorage, while bioactive surface treatment ensures development of biological stability.

  14. Non-linear 3D evaluation of different oral implant-abutment connections.

    PubMed

    Streckbein, P; Streckbein, R G; Wilbrand, J F; Malik, C Y; Schaaf, H; Howaldt, H P; Flach, M

    2012-12-01

    Micro-gaps and osseous overload in the implant-abutment connection are the most common causes of peri-implant bone resorption and implant failure. These undesirable events can be visualized on standardized three-dimensional finite element models and by radiographic methods. The present study investigated the influence of 7 available implant systems (Ankylos, Astra, Bego, Brånemark, Camlog, Straumann, and Xive) with different implant-abutment connections on bone overload and the appearance of micro-gaps in vitro. The individual geometries of the implants were transferred to three-dimensional finite element models. In a non-linear analysis considering the pre-loading of the occlusion screw, friction between the implant and abutment, the influence of the cone angle on bone strain, and the appearance of micro-gaps were determined. Increased bone strains were correlated with small (< 15°) cone angles. Conical implant-abutment connections efficiently avoided micro-gaps but had a negative effect on peri-implant bone strain. Bone strain was reduced in implants with greater wall thickness (Ankylos) or a smaller cone angle (Bego). The results of our in silico study provide a solid basis for the reduction of peri-implant bone strain and micro-gaps in the implant-abutment connection to improve long-term stability.

  15. Development and Applications of Porous Tantalum Trabecular Metal Enhanced Titanium Dental Implants

    PubMed Central

    Bencharit, Sompop; Byrd, Warren C.; Altarawneh, Sandra; Hosseini, Bashir; Leong, Austin; Reside, Glenn; Morelli, Thiago; Offenbacher, Steven

    2013-01-01

    Statement of Problem Porous tantalum trabecular metal has recently been incorporated in titanium dental implants as a new form of implant surface enhancement. However, there is little information on the applications of this material in implant dentistry. Methods We, therefore review the current literature on the basic science and clinical uses of this material. Results Porous tantalum metal is used to improve the contact between osseous structure and dental implants; and therefore presumably facilitate osseointegration. Success of porous tantalum metal in orthopedic implants led to the incorporation of porous tantalum metal in the design of root-from endosseous titanium implants. The porous tantalum three-dimensional enhancement of titanium dental implant surface allows for combining bone ongrowth together with bone ingrowth, or osseoincorporation. While little is known about the biological aspect of the porous tantalum in the oral cavity, there seems to be several possible advantages of this implant design. This article reviews the biological aspects of porous tantalum enhanced titanium dental implants, in particular the effects of anatomical consideration and oral environment to implant designs. Conclusions We propose here possible clinical situations and applications for this type of dental implant. Advantages and disadvantages of the implants as well as needed future clinical studies are discussed. PMID:23527899

  16. Experimental investigation of commercial small diameter dental implants in porcine mandibular segments.

    PubMed

    Hasan, Istabrak; Heinemann, Friedhelm; Schwegmann, Monika; Keilig, Ludger; Stark, Helmut; Bourauel, Christoph

    2017-02-01

    Small diameter (mini) dental implants have become more popular in recent years as alternatives to classical implant treatment in clinical cases with critical bony situations. However, an in-depth scientific analysis of the mechanical and biomechanical effects of small diameter implants has not yet been published. The aim of the present study was to investigate experimentally different commercial mini implants by measuring their displacements under immediate loading. Twelve commercially available mini implants were measured. Implants were inserted into porcine mandibular segments and loaded by means of a predefined displacement of 0.5 mm of the loading system. The implants were loaded at an angle of 30° to the implant long axis using the self-developed biomechanical hexapod measurement system. Implant displacements were registered. The experimental results were compared to the numerical ones from a previous study. Measured implant displacements were within the range of 39-194 μm. A large variation in the displacements was obtained among the different implant systems due to the different designs and thread profiles. Comparing experimental and numerical results, the displacements that were obtained numerically were within the range of 79-347 μm. The different commercial mini implants showed acceptable primary stability and could be loaded immediately after their insertion.

  17. Enhanced osseointegration of titanium implants in a rat model of osteoporosis using multilayer bone mesenchymal stem cell sheets

    PubMed Central

    Duan, Yan; Ma, Wei; Li, Dehua; Wang, Tongfei; Liu, Baolin

    2017-01-01

    The present study aimed to investigate whether bone marrow-derived mesenchymal stem cell (BMSC) sheets combined with titanium implants enhanced implant osseointegration in an ovariectomized (OVX) rat model of osteoporosis. Sprague-Dawley rats were randomly assigned into a test group and control group. Allogenic BMSCs were collected from the rats, cultured and stored via cryopreservation. At 6 months post-ovariectomy, establishment of the OVX model was confirmed by micro-computed tomography (CT) measurements. BMSC sheets were subsequently layered and wrapped over titanium implants for implantation. Unmodified implants served as the control. At 8 weeks post-implantation, samples were observed by micro-CT reconstruction and histomorphometric evaluation. Micro-CT reconstruction identified a marked improvement in the surrounding bone volume following treatment, with data analyses indicating a significant increase in bone volume in the BMSC-implant group compared with the control implant group (P<0.05). In addition, histological staining identified new bone formation and an increased rate of bone-implant contact surrounding the BMSC-implant constructs. These results indicate that the use of BMSC sheets as a novel tissue engineering approach improves the osseointegration of titanium implants in an osteoporosis model. This method may expand the operative indications in patients with osteoporosis and improve the success rate of clinical dental implant treatments. PMID:29250137

  18. New Criteria of Indication and Selection of Patients to Cochlear Implant

    PubMed Central

    Sampaio, André L. L.; Araújo, Mercêdes F. S.; Oliveira, Carlos A. C. P.

    2011-01-01

    Numerous changes continue to occur in cochlear implant candidacy. In general, these have been accompanied by concomitant and satisfactory changes in surgical techniques. Together, this has advanced the utility and safety of cochlear implantation. Most devices are now approved for use in patients with severe to profound unilateral hearing loss rather then the prior requirement of a bilateral profound loss. Furthermore, studies have begun utilizing short electrode arrays for shallow insertion in patients with considerable low-frequency residual hearing. This technique will allow the recipient to continue to use acoustically amplified hearing for the low frequencies simultaneously with a cochlear implant for the high frequencies. The advances in design of, and indications for, cochlear implants have been matched by improvements in surgical techniques and decrease in complications. The resulting improvements in safety and efficacy have further encouraged the use of these devices. This paper will review the new concepts in the candidacy of cochlear implant. Medline data base was used to search articles dealing with the following topics: cochlear implant in younger children, cochlear implant and hearing preservation, cochlear implant for unilateral deafness and tinnitus, genetic hearing loss and cochlear implant, bilateral cochlear implant, neuropathy and cochlear implant and neural plasticity, and the selection of patients for cochlear implant. PMID:22013448

  19. Dose Control System in the Optima XE Single Wafer High Energy Ion Implanter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Satoh, Shu; Yoon, Jongyoon; David, Jonathan

    2011-01-07

    Photoresist outgassing can significantly compromise accurate dosimetry of high energy implants. High energy implant even at a modest beam current produces high beam powers which create significantly worse outgassing than low and medium energy implants and the outgassing continues throughout the implant due to the low dose in typical high energy implant recipes. In the previous generation of high energy implanters, dose correction by monitoring of process chamber pressure during photoresist outgassing has been used. However, as applications diversify and requirements change, the need arises for a more versatile photoresist correction system to match the versatility of a single wafermore » high energy ion implanter. We have successfully developed a new dosimetry system for the Optima XE single wafer high energy ion implanter which does not require any form of compensation due to the implant conditions. This paper describes the principles and performance of this new dose system.« less

  20. The Dexamethasone Intravitreal Implant for Noninfectious Uveitis: Practice Patterns Among Uveitis Specialists.

    PubMed

    Burkholder, Bryn M; Moradi, Ahmadreza; Thorne, Jennifer E; Dunn, James P

    2015-01-01

    To describe the practice patterns and perceptions of uveitis specialists regarding the use of the intravitreal dexamethasone (DEX) implant for the treatment of noninfectious uveitis. We invited uveitis specialists to participate in an anonymous online survey. Among the 45 respondents, 76.5% identified uveitic macular edema as the most common clinical finding for which they use the DEX implant. The most common contraindications to DEX implantation were aphakia and glaucoma requiring >2 medications. Nearly two-thirds (64.3%) felt that the advent of the DEX implant did not change the frequency with which they used the fluocinolone acetonide (FA) implant, and about one-third (32.3%) preferred to use at least one DEX implant, before committing a patient to an FA implant. Uveitis physicians use the DEX implant for a wide range of clinical findings and uveitic diagnoses. There was no clear consensus on preferences regarding the use of DEX versus FA implants.

  1. The effect of implant number and position on the stress behavior of mandibular implant retained overdentures: A three-dimensional finite element analysis.

    PubMed

    Topkaya, Tolga; Solmaz, Murat Yavuz

    2015-07-16

    The present study evaluated the effects of ball anchor abutment attached to implants with a 4.30 mm diameter and 11 mm insert length on stress distribution in a patient without any remaining teeth in the lower jaw. In the study, the stress analysis was performed for five different configurations (2 with 4 implant-supported and 3 with 2 implant-supported) and three different loading types using ANSYS Workbench software. The stresses measured in the 4 implant-supported models were lower compared to the stresses measured in the 2 implant-supported models. The stresses on the implants intensified on the cervical region of the implants. When the effects of the loading sites on the stress were examined, the loading on the first molar tooth produced the highest stresses on the implants. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Accuracy of computer-guided implantation in a human cadaver model.

    PubMed

    Yatzkair, Gustavo; Cheng, Alice; Brodie, Stan; Raviv, Eli; Boyan, Barbara D; Schwartz, Zvi

    2015-10-01

    To examine the accuracy of computer-guided implantation using a human cadaver model with reduced experimental variability. Twenty-eight (28) dental implants representing 12 clinical cases were placed in four cadaver heads using a static guided implantation template. All planning and surgeries were performed by one clinician. All radiographs and measurements were performed by two examiners. The distance of the implants from buccal and lingual bone and mesial implant or tooth was analyzed at the apical and coronal levels, and measurements were compared to the planned values. No significant differences were seen between planned and implanted measurements. Average deviation of an implant from its planning radiograph was 0.8 mm, which is within the range of variability expected from CT analysis. Guided implantation can be used safely with a margin of error of 1 mm. © 2014 The Authors. Clinical Oral Implants Research Published by John Wiley & Sons Ltd.

  3. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants

    PubMed Central

    Du, Jing; Lee, Jihyun; Jang, Andrew; Gu, Allen; Hossaini-Zadeh, Mehran; Prevost, Richard; Curtis, Don; Ho, Sunita

    2015-01-01

    The effects of alveolar bone socket geometry and bone-implant contact on implant biomechanics, and resulting strain distributions in bone were investigated. Following extraction of lateral incisors on a cadaver mandible, immediate implants were placed and bone-implant contact area, stability and bone strain were measured. In situ biomechanical testing coupled with micro X-ray microscope (μ-XRM) illustrated less stiff bone-implant complexes (701-822 N/mm) compared with bone-periodontal ligament (PDL)-tooth complexes (791-913 N/mm). X-ray tomograms illustrated that the cause of reduced stiffness was due to reduced and limited bone-implant contact. Heterogeneous elemental composition of bone was identified by using energy dispersive X-ray spectroscopy (EDS). The novel aspect of this study was the application of a new experimental mechanics method, that is, digital volume correlation, which allowed mapping of strains in volumes of alveolar bone in contact with a loaded implant. The identified surface and subsurface strain concentrations were a manifestation of load transferred to bone through bone-implant contact based on bone-implant geometry, quality of bone, implant placement, and implant design. 3D strain mapping indicated that strain concentrations are not exclusive to the bone-implant contact regions, but also extend into bone not directly in contact with the implant. The implications of the observed strain concentrations are discussed in the context of mechanobiology. Although a plausible explanation of surgical complications for immediate implant treatment is provided, extrapolation of results is only warranted by future systematic studies on more cadaver specimens and/or in vivo small scale animal models. PMID:26162549

  4. Rupture rate and patterns of shell failure with the McGhan Style 153 double-lumen breast implant.

    PubMed

    Neaman, Keith C; Albert, Mark; Hammond, Dennis C

    2011-01-01

    In 2005, the McGhan Style 153 double-lumen breast implant was removed from the market secondary to a higher rupture rate when contrasted with other implants in the Core Study group. The high rupture rate was attributed to the development of a posterior tear in the shell where the inner implant is bonded to the posterior wall of the device. The purpose of this study was to report the existing rupture rate and describe the apparent mechanism of failure in the Style 153 double-lumen breast implant. Ninety-seven patients (157 implants) who received the McGhan Style 153 double-lumen breast implant by the senior author were reviewed. Intraoperative observations and photographic images of ruptured implants were reviewed and characterized based on severity and location of implant rupture. With a mean length of follow-up of greater than 6 years (82 months), the rupture rate was 19.1 percent per implant. Physical examination (60 percent) was the most common method of rupture detection. Ruptures tended to occur in the marginal aspect (63 percent) of the implant. Only three ruptures occurred secondary to a disruption of the inner bladder from the posterior portion of the implant. The rupture rate of the Style 153 double-lumen breast implant is higher than previously thought, with a rate of 19.1 percent. A majority of ruptures occurred in the peripheral aspects of the implant. It is postulated that these ruptures were likely secondary to fold flaws that led to failure of the implant shell.

  5. Soft-Tissue Grafting Techniques Associated With Immediate Implant Placement.

    PubMed

    Bishara, Mark; Kurtzman, Gregori M; Khan, Waji; Choukroun, Joseph; Miron, Richard J

    2018-02-01

    Immediate implant placement often presents challenges in terms of predictably obtaining soft-tissue coverage over the implant site. While delayed implant placement offers the ability for soft tissues to grow and invade the extraction socket making their attachment around implants more predictable, immediate implant placement poses a significant risk of bacterial invasion towards the implant surface as a result of insignificant soft-tissue volume. Soft-tissue grafting techniques have often been proposed for use during immediate implant placement to augment soft-tissue deficiencies, including the use of either palatal connective tissue grafts (CTGs) or collagen-derived scaffolds. However, both of these approaches have significant drawbacks in that CTGs are harvested with high patient morbidity and collagen scaffolds remain avascular and acelluar posing a risk of infection/implant contamination. More recently, platelet-rich fibrin (PRF) has been proposed as an economical and biological means to speed soft-tissue wound healing. In combination with immediate implant placement, PRF offers an easily procurable low-cost regenerative modality that offers an efficient way to improve soft-tissue attachment around implants. Furthermore, the supra-physiological concentration of defense-fighting leukocytes in PRF, combined with a dense fibrin meshwork, is known to prevent early bacterial contamination of implant surfaces, and the biological concentrations of autologous growth factors in PRF is known to increase tissue regeneration. This article discusses soft-tissue grafting techniques associated with immediate implant placement, presents several cases demonstrating the use of PRF in routine immediate implant placement, and further discusses the biological and economic advantages of PRF for the management of soft-tissue grafting during immediate implant placement.

  6. Osseointegration is improved by coating titanium implants with a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon.

    PubMed

    Veronesi, Francesca; Giavaresi, Gianluca; Fini, Milena; Longo, Giovanni; Ioannidu, Caterina Alexandra; Scotto d'Abusco, Anna; Superti, Fabiana; Panzini, Gianluca; Misiano, Carlo; Palattella, Alberto; Selleri, Paolo; Di Girolamo, Nicola; Garbarino, Viola; Politi, Laura; Scandurra, Roberto

    2017-01-01

    Titanium implants coated with a 500nm nanostructured layer, deposited by the Ion Plating Plasma Assisted (IPPA) technology, composed of 60% graphitic carbon, 25% titanium oxides and 15% titanium carbide were implanted into rabbit femurs whilst into the controlateral femurs uncoated titanium implants were inserted as control. At four time points the animals were injected with calcein green, xylenol orange, oxytetracycline and alizarin. After 2, 4 and 8weeks femurs were removed and processed for histology and static and dynamic histomorphometry for undecalcified bone processing into methylmethacrylate, sectioned, thinned, polished and stained with Toluidine blue and Fast green. The overall bone-implant contacts rate (percentage of bone-implant contacts/weeks) of the TiC coated implant was 1.6 fold than that of the uncoated titanium implant. The histomorphometric analyses confirmed the histological evaluations. More precisely, higher Mineral Apposition Rate (MAR, μm/day) (p<0.005) and Bone Formation Rate (BFR, μm 2 /μm/day) (p<0.0005) as well as Bone Implant Contact (Bic) and Bone Ingrowth values (p<0.0005) were observed for the TiC coated implants compared to uncoated implants. In conclusion the hard nanostructured TiC layer protects the bulk titanium implant against the harsh conditions of biological tissues and in the same time, stimulating adhesion, proliferation and activity of osteoblasts, induces a better bone-implant contacts of the implant compared to the uncoated titanium implant. Copyright © 2016. Published by Elsevier B.V.

  7. Ultraviolet-C irradiation to titanium implants increases peri-implant bone formation without impeding mineralization in a rabbit femur model.

    PubMed

    Yamazaki, Makoto; Yamada, Masahiro; Ishizaki, Ken; Sakurai, Kaoru

    2015-05-01

    Volume and bone quality of peri-implant supporting bone, in particular, at implant neck region, as well as bone-implant contact ratio, is important for long-term stability of implants. Ultraviolet-C (UVC) irradiation is known to enhance the osseointegration capability of titanium implants. However, the histological determination was performed only on a rat model, but not pre-clinical animal model such as a rabbit model. The purpose of this study was to determine the effects of UVC irradiation on titanium implants on the volume and mineral density of peri-implant supporting bone formation in a rabbit femur model. Acid-etched pure titanium screw implants with or without 3 mW/cm2 UVC irradiation for 48 h were placed in rabbit femur diaphyses. Peri-implant bone tissue formation was analyzed at 3 and 8 weeks post-operatively by histology and micro-CT-based bone morphometry after calibration with hydroxyl apatite phantoms. UVC pre-irradiated implants accumulated a higher density of cells and thicker and longer bone tissue attachments that continued into the inner basic lamellae of the surface of existing cortical bone at 3 and 8 weeks than the implants without irradiation. Although the bone mineral density around both implants was equivalent to that of the existing cortical bone, bone volume was greater with UVC pre-irradiation in two-thirds or more of the apical region throughout the observation period. These results indicate that UVC treatment increased the volume of cortical-like bone tissue in the coronal region of titanium implants without deterioration of bone mineral density.

  8. Percutaneous Implants with Porous Titanium Dermal Barriers: An In Vivo Evaluation of Infection Risk

    PubMed Central

    Isackson, Dorthyann; McGill, Lawrence D.; Bachus, Kent N.

    2010-01-01

    Osseointegrated percutaneous implants are a promising prosthetic alternative for a subset of amputees. However, as with all percutaneous implants, they have an increased risk of infection since they breach the skin barrier. Theoretically, host tissues could attach to the metal implant creating a barrier to infection. When compared with smooth surfaces, it is hypothesized that porous surfaces improve the attachment of the host tissues to the implant, and decrease the infection risk. In this study, 4 titanium implants, manufactured with a percutaneous post and a subcutaneous disk, were placed subcutaneously on the dorsum of eight New Zealand White rabbits. Beginning at four weeks post-op, the implants were inoculated weekly with 108 CFU Staphylococcus aureus until signs of clinical infection presented. While we were unable to detect a difference in the incidence of infection of the porous metal implants, smooth surface (no porous coating) percutaneous and subcutaneous components had a 7-fold increased risk of infection compared to the implants with a porous coating on one or both components. The porous coated implants displayed excellent tissue ingrowth into the porous structures; whereas, the smooth implants were surrounded with a thick, organized fibrotic capsule that was separated from the implant surface. This study suggests that porous coated metal percutaneous implants are at a significantly lower risk of infection when compared to smooth metal implants. The smooth surface percutaneous implants were inadequate in allowing a long-term seal to develop with the soft tissue, thus increasing vulnerability to the migration of infecting microorganisms. PMID:21145778

  9. Characteristics of contact and distance osteogenesis around modified implant surfaces in rabbit tibiae

    PubMed Central

    2017-01-01

    Purpose Contact and distance osteogenesis occur around all endosseous dental implants. However, the mechanisms underlying these processes have not been fully elucidated. We hypothesized that these processes occur independently of each other. To test this, we used titanium (Ti) tubes to physically separate contact and distance osteogenesis, thus allowing contact osteogenesis to be measured in the absence of possible triggers from distance osteogenesis. Methods Sandblasted and acid-etched (SLA) and modified SLA (modSLA) implants were used. Both types had been sandblasted with large grit and then etched with acid. The modSLA implants then underwent additional treatment to increase hydrophilicity. The implants were implanted into rabbit tibiae, and half were implanted within Ti tubes. The bone-to-implant contact (BIC) ratio was calculated for each implant. Immunohistochemical analyses of bone morphogenetic protein (BMP)-2 expression and new bone formation (Masson trichrome stain) were performed. Results The implants outside of Ti tubes were associated with good bone formation along the implant surface. Implantation within a Ti tube significantly reduced the BIC ratio (P<0.001). Compared with the modSLA implants, the SLA implants were associated with significantly higher BIC ratios, regardless of the presence or absence of Ti tubes (P=0.043). In the absence of Ti tubes, the bone adjacent to the implant had areas of new bone formation that expressed BMP-2 at high levels. Conclusions This study disproved the null hypothesis and suggested that contact osteogenesis is initiated by signals from the old bone that undergoes distance osteogenesis after drilling. This signal may be BMP-2. PMID:28680714

  10. A retrospective study of sintered porous-surfaced dental implants in restoring the edentulous posterior mandible: up to 9 years of functioning.

    PubMed

    Sohn, Dong-Seok; Kim, Woo-Sung; Lee, Won-Hyuk; Jung, Heui-Seung; Shin, Im-Hee

    2010-10-01

    The aim of this retrospective study was to evaluate the survival rate of sintered porous-surfaced implants placed in the edentulous posterior mandibles, in relation to implant length and diameter, crown-to-implant ratio, and types of prostheses, for a maximum of 9 years of functioning (mean: 55.8 months; range: 5-108 months). The study group consisted of 43 partially edentulous patients who visited Catholic University Hospital of Daegu and 1 private dental clinic. A total of 122 sintered porous-surfaced implants--Endopore (Innova Life Sciences, Toronto, Ontario, Canada)--were placed in the edentulous posterior mandibles. Two diameter sizes (4.1 and 5.0 mm) and 4 lengths (5.0, 7.0, 9.0, and 12.0 mm) were used. All implants were restored with fixed prostheses. One hundred three implants were splinted and 21 implants were nonsplinted. Panoramic views and periapical radiographs were taken at the time of the first, postoperative, crown placement, and following checkup visits. The survival rates of the implants in relation to length, diameter, crown-to-implant ratio, and types of prostheses were investigated. Statistical data were analyzed using SPSS Win.Ver 14.0 software with the χ² test. The survival rate of the 4.1-mm-diameter implants was 100% and 91.2% for the 5.0-mm-diameter implants. The survival rates of the implants of differing diameters were found to be statistically different (P = 0.005). The survival rates of both the 5.0-mm and 7.0-mm-length implants were 100%. The survival rate of the 9.0-mm-length implants was 97.9% and for the 12.0-mm-length implants was 95.1%. There was no statistical difference in survival rates for the differing lengths of implants. Of the 103 prostheses that were splinted, the survival rate was 98.0%. The survival rate of splinted prostheses was higher than that of the nonsplinted prostheses but was found to be not statistically different. There were no failed cases when the crown-to-implant ratio was <1.0. When the crown-to-implant ratio was between 1.0 and 1.4, the failure rate of the implants was 6.7%. No failure was recorded with the ratio range of 1.5 to 2.0. Relative to the crown-to-implant ratio of 1.0, the failure rates were statistically different (P = 0.048). The cumulative survival rate of the porous-surfaced implants placed in the edentulous posterior mandibles was 97.5%. Short porous-surfaced implants showed satisfactory results after a maximum of 9 years of functioning in the edentulous posterior mandibles.

  11. Implantable biomedical devices on bioresorbable substrates

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rogers, John A.; Kim, Dae-Hyeong; Omenetto, Fiorenzo

    Provided herein are implantable biomedical devices and methods of administering implantable biomedical devices, making implantable biomedical devices, and using implantable biomedical devices to actuate a target tissue or sense a parameter associated with the target tissue in a biological environment.

  12. Biomaterials and host versus graft response: A short review

    PubMed Central

    Velnar, Tomaz; Bunc, Gorazd; Klobucar, Robert; Gradisnik, Lidija

    2016-01-01

    Biomaterials and biotechnology are increasing becoming an important area in modern medicine. The main aim in this area is the development of materials, which are biocompatible to normal tissue. Tissue-implant interactions with molecular, biological and cellular characteristics at the implant-tissue interface are important for the use and development of implants. Implantation may cause an inflammatory and immune response in tissue, foreign body reaction, systemic toxicity and imminent infection. Tissue-implant interactions determine the implant life-period. The aims of the study are to consider the biological response to implants. Biomaterials and host reactions to implants and their mechanisms are also briefly discussed. PMID:26894284

  13. PEEK with Reinforced Materials and Modifications for Dental Implant Applications

    PubMed Central

    Rahmitasari, Fitria; Ishida, Yuichi; Kurahashi, Kosuke; Matsuda, Takashi; Watanabe, Megumi

    2017-01-01

    Polyetheretherketone (PEEK) is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary. PMID:29563441

  14. PEEK with Reinforced Materials and Modifications for Dental Implant Applications.

    PubMed

    Rahmitasari, Fitria; Ishida, Yuichi; Kurahashi, Kosuke; Matsuda, Takashi; Watanabe, Megumi; Ichikawa, Tetsuo

    2017-12-15

    Polyetheretherketone (PEEK) is a semi-crystalline linear polycyclic thermoplastic that has been proposed as a substitute for metals in biomaterials. PEEK can also be applied to dental implant materials as a superstructure, implant abutment, or implant body. This article summarizes the current research on PEEK applications in dental implants, especially for the improvement of PEEK surface and body modifications. Although various benchmark reports on the reinforcement and surface modifications of PEEK are available, few clinical trials using PEEK for dental implant bodies have been published. Controlled clinical trials, especially for the use of PEEK in implant abutment and implant bodies, are necessary.

  15. The effect of sol-gel-formed calcium phosphate coatings on bone ingrowth and osteoconductivity of porous-surfaced Ti alloy implants.

    PubMed

    Nguyen, H Q; Deporter, D A; Pilliar, R M; Valiquette, N; Yakubovich, R

    2004-02-01

    Ti-6Al-4V implants formed with a sintered porous surface for implant fixation by bone ingrowth were prepared with or without the addition of a thin surface layer of calcium phosphate (Ca-P) formed using a sol-gel coating technique over the porous surface. The implants were placed transversely across the tibiae of 17 rabbits. Implanted sites were allowed to heal for 2 weeks, after which specimens were retrieved for morphometric assessment using backscattered scanning electron microscopy and quantitative image analysis. Bone formation along the porous-structured implant surface, was measured in relation to the medial and lateral cortices as an indication of implant surface osteoconductivity. The Absolute Contact Length measurements of endosteal bone growth along the porous-surfaced zone were greater with the Ca-P-coated implants compared to the non-Ca-P-coated implants. The Ca-P-coated implants also displayed a trend towards a significant increase in the area of bone ingrowth (Bone Ingrowth Fraction). Finally, there was significantly greater bone-to-implant contact within the sinter neck regions of the Ca-P-coated implants.

  16. Clinical Outcome of Hydroxyapatite Coated, Bioactive Glass Coated, and Machined Ti6Al4V Threaded Dental Implant in Human Jaws: A Short-Term Comparative Study.

    PubMed

    Mistry, Surajit; Roy, Rajiv; Kundu, Biswanath; Datta, Someswar; Kumar, Manoj; Chanda, Abhijit; Kundu, Debabrata

    2016-04-01

    Growing aspect of endosseous implant research is focused on surface modification of dental implants for the purpose of improving osseointegration. The aim of this study was to evaluate and compare the clinical outcome (ie, osseointegration) of hydroxyapatite coated, bioactive glass coated and machined titanium alloy threaded dental implants in human jaw bone after implantation. One hundred twenty-six implants (45 hydroxyapatite coated, 41 bioactive glass coated, and 40 machined titanium implants) have been placed in incisor areas of 62 adult patients. Outcome was assessed up to 12 months after prosthetic rehabilitation using different clinical and radiological parameters. Surface roughness of failed implants was analyzed by laser profilometer. Hydroxyapatite and bioactive glass coating materials were nontoxic and biocompatible. Least marginal bone loss in radiograph, significantly higher (P < 0.05) interface radiodensity, and less interfacial gaps were observed in computed tomography with bioactive glass coated implants at anterior maxilla compared to other 2 types. Bioactive glass coated implants are equally safe and effective as hydroxyapatite coated and machined titanium implants in achieving osseointegration; therefore, can be effectively used as an alternative coating material for dental implants.

  17. Health, Maintenance, and Recovery of Soft Tissues around Implants.

    PubMed

    Wang, Yulan; Zhang, Yufeng; Miron, Richard J

    2016-06-01

    The health of peri-implant soft tissues is one of the most important aspects of osseointegration necessary for the long-term survival of dental implants. To review the process of soft tissue healing around osseointegrated implants and discuss the maintenance requirements as well as the possible short-comings of peri-implant soft tissue integration. Literature search on the process involved in osseointegration, soft tissue healing and currently available treatment modalities was performed and a brief description of each process was provided. The peri-implant interface has been shown to be less effective than natural teeth in resisting bacterial invasion because gingival fiber alignment and reduced vascular supply make it more vulnerable to subsequent peri-implant disease and future bone loss around implants. And we summarized common procedures which have been shown to be effective in preventing peri-implantitis disease progression as well as clinical techniques utilized to regenerate soft tissues with bone loss in advanced cases of peri-implantitis. Due to the difference between peri-implant interface and natural teeth, clinicians and patients should pay more attention in the maintenance and recovery of soft tissues around implants. © 2015 Wiley Periodicals, Inc.

  18. Effect of trehalose coating on basic fibroblast growth factor release from tailor-made bone implants.

    PubMed

    Choi, Sungjin; Lee, Jongil; Igawa, Kazuyo; Suzuki, Shigeki; Mochizuki, Manabu; Nishimura, Ryohei; Chung, Ung-il; Sasaki, Nobuo

    2011-12-01

    Artificial bone implants are often incorporated with osteoinductive factors to facilitate early bone regeneration. Calcium phosphate, the main component in artificial bone implants, strongly binds these factors, and in a few cases, the incorporated proteins are not released from the implant under conditions of physiological pH, thereby leading to reduction in their osteoinductivity. In this study, we coated tailor-made bone implants with trehalose to facilitate the release of basic fibroblast growth factor (bFGF). In an in vitro study, mouse osteoblastic cells were separately cultured for 48 hr in a medium with a untreated implant (T-), trehalose-coated implant (T+), bFGF-incorporated implant (FT-), and bFGF-incorporated implant with trehalose coating (FT+). In the FT+ group, cell viability was significantly higher than that in the other groups (P<0.05). Scanning electron microscopy (SEM) and X-ray diffraction (XRD) revealed that trehalose effectively covered the surface of the artificial bone implant without affecting the crystallinity or the mechanical strength of the artificial bone implant. These results suggest that coating artificial bone implants with trehalose could limit the binding of bFGF to calcium phosphate.

  19. Does milling one-piece titanium dental implants induce osteocyte and osteoclast changes?

    PubMed

    Russe, P; Pascaretti-Grizon, F; Aguado, E; Goyenvale, E; Filmon, R; Baslé, M-F; Chappard, D

    2011-06-01

    One-piece dental implants avoid adverse effects sometimes associated with the traditional implant-abutment interface and may provide a suitable alternative to two-piece implants; however, one-piece implants often need in situ milling, which may exacerbate cell apoptosis from excessive heat at the bone-implant interface and induce secondary crestal bone loss. Twelve implants were placed in the metaphyses of two sheep under general anesthesia. Six implants were milled with a diamond bur while the other six implants remained intact. Animals were euthanized after four days, and bone blocks were harvested. Bone samples were studied without decalcification. Osteocytes were stained with Hoechst 33342 and osteoclasts by the TRAcP reaction. Both cell types, in the cortical and trabecular bone around the implant's cervical region, were counted utilizing morphometric methods. Values were compared to areas at a distance from the cervical region. No difference was observed between milled and unmilled implants, which suggested that the amount of generated heat did not provoke osteocyte loss or induce osteoclastogenesis. Intraoral abutment preparations did not increase cellular apoptosis at the bone-implant interface after four days in the ovine model. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  20. Tantalum implanted entangled porous titanium promotes surface osseointegration and bone ingrowth

    NASA Astrophysics Data System (ADS)

    Wang, Qi; Qiao, Yuqin; Cheng, Mengqi; Jiang, Guofeng; He, Guo; Chen, Yunsu; Zhang, Xianlong; Liu, Xuanyong

    2016-05-01

    Porous Ti is considered to be an ideal graft material in orthopaedic and dental surgeries due to its similar spatial structures and mechanical properties to cancellous bone. In this work, to overcome the bioinertia of Ti, Ta-implanted entangled porous titanium (EPT) was constructed by plasma immersion ion implantation & deposition (PIII&D) method. Ca-implanted and unimplanted EPTs were investigated as control groups. Although no difference was found in surface topography and mechanical performances, both Ca- and Ta-implanted groups had better effects in promoting MG-63 cell viability, proliferation, differentiation, and mineralization than those of unimplanted group. The expression of osteogenic-related markers examined by qRT-PCR and western blotting was upregulated in Ca- and Ta-implanted groups. Moreover, Ta-implanted EPT group could reach a higher level of these effects than that of Ca-implanted group. Enhanced osseointegration of both Ca- and Ta-implanted EPT implants was demonstrated through in vivo experiments, including micro-CT evaluation, push-out test, sequential fluorescent labeling and histological observation. However, the Ta-implanted group possessed more stable and continuous osteogenic activity. Our results suggest that Ta-implanted EPT can be developed as one of the highly efficient graft material for bone reconstruction situations.

  1. Histologic and histomorphometric evaluation of peri-implant bone of immediate or delayed occlusal-loaded non-splinted implants in the posterior mandible--an experimental study in monkeys.

    PubMed

    Stokholm, Rie; Isidor, Flemming; Nyengaard, Jens R

    2014-11-01

    The primary aim of this study was to compare the bone reaction around immediate-loaded non-splinted single implants vs. delayed loaded non-splinted single implants placed in healed ridges in the posterior mandible. Six adult Macaca Fascicularis monkeys were used in this study. The first and second premolars and the first molar were extracted in both sides of the mandible. After 3 months of healing, four implants (Replace Select Tapered; Nobel Biocare, Gothenburg, Sweden) with a moderately rough surface (TiUnite, Nobel Biocare) were placed in the edentulous areas of each monkey, two in each side. The implants had a length of 10 mm and a diameter of 3.5 mm. Four groups of varying time and occlusal loading aspects were created: (i) control group: implant placed non-loaded for 3 months; (ii) immediate loaded: implant placed and loaded immediately for 3 months; (iii) immediate loaded: implant placed and loaded immediately for 6 months; and (iv) delayed loaded: implant placed submerged for 3 months and then loaded for 3 months. At the loaded implants, after a second stage surgery, a composite crown was made directly on an abutment mounted on the implant reinsuring simultaneous occlusal contact on the implant crown and the neighboring teeth. After euthanization of the animals, histologic specimens were quantified in the light microscope. All implants were clinically, radiographically, and histologically osseointegrated at the time of euthanization and with only mild signs of inflammation in the peri-implant mucosa. The histologic marginal bone level was located on average 1.14-1.74 mm apical to the margin of the implants in the various groups. The average bone-to-implant contact (BIC) varied between 55% and 65% and the average bone density (i.e., the proportion of mineralized bone tissue from the implant surface and to a distance of 1 mm lateral to the implant) varied between 30.6% and 34.2%. No statistical significant differences between groups were observed in the above-stated histomorphometric parameters. Similar histologic and histomorphometric findings were observed in immediately and delayed loaded non-splinted implants placed in the posterior mandible of macaque monkeys. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. Implant decontamination with phosphoric acid during surgical peri-implantitis treatment: a RCT.

    PubMed

    Hentenaar, Diederik F M; De Waal, Yvonne C M; Strooker, Hans; Meijer, Henny J A; Van Winkelhoff, Arie-Jan; Raghoebar, Gerry M

    2017-12-01

    Peri-implantitis is known as an infectious disease that affects the peri-implant soft and hard tissue. Today, scientific literature provides very little evidence for an effective intervention protocol for treatment of peri-implantitis. The aim of the present randomized controlled trial is to evaluate the microbiological and clinical effectiveness of phosphoric acid as a decontaminating agent of the implant surface during surgical peri-implantitis treatment. Peri-implantitis lesions were treated with resective surgical treatment aimed at peri-implant granulation tissue removal, bone recontouring, and pocket elimination. Fifty-three implant surfaces in 28 patients were mechanically cleaned and treated with either 35% phosphoric etching gel (test group) or sterile saline (control group). Microbiological samples were obtained during surgery; clinical parameters were recorded at baseline and at 3 months after treatment. Data were analyzed using multi-variable linear regression analysis and multilevel statistics. Significant immediate reductions in total anaerobic bacterial counts on the implant surface were found in both groups. Immediate reduction was greater when phosphoric acid was used. The difference in log-transformed mean anaerobic counts between both procedures was not statistical significant (p = 0.108), but there were significantly less culture-positive implants after the decontamination procedure in the phosphoric acid group (p = 0.042). At 3 months post-surgery, 75% of the implants in the control group and 63.3% of the implants in the test group showed disease resolution. However, no significant differences in clinical and microbiological outcomes between both groups were found. The application of 35% phosphoric acid after mechanical debridement is superior to mechanical debridement combined with sterile saline rinsing for decontamination of the implant surface during surgical peri-implantitis treatment. However, phosphoric acid as implant surface decontaminant does not seem to enhance clinical outcomes on a 3-month follow-up. Netherlands National Trial Register, NTR5185 (www.trialregister.nl).

  3. Evaluation of an education and follow-up programme for implantable cardioverter defibrillator-implanted patients.

    PubMed

    Cinar, Fatma I; Tosun, Nuran; Kose, Sedat

    2013-09-01

    To determine the experiences, problems and the need for care and education of implantable cardioverter defibrillator-implanted patients and to assess the effects of an education and nurse follow-up programme on their quality of life, anxiety, depression and knowledge level. Although implantable cardioverter defibrillator has become a well-established therapy for people experiencing potentially lethal dysrhythmias, implantable cardioverter defibrillator patients may have physical and psychosocial problems due to the implantation. Applying a planning education and follow-up programme to implantable cardioverter defibrillator-implanted patients may prevent the need for more intensive treatment during the postimplantation period. A mixed methods design that used both qualitative and quantitative data collections and analysis was used for this study. The study was performed in the cardiology department in Turkey between 2009-2010. The data were collected using the 'Semi-Structured Interview Form', 'Form for Assessment of Patients' Knowledge Level about implantable cardioverter defibrillator', 'Spielberger's State-Trait Anxiety Inventory', 'Beck Depression Inventory II' and 'The Short-Form 36 Health Survey'. All forms were completed at the beginning of the study and at six months. The study included 27 patients in the experimental group and 27 patients in the control group. The results showed that the patients were living with various physical and psychosocial problems and insufficient knowledge regarding the implantable cardioverter defibrillator. Education and follow-up programme increased knowledge levels, decreased anxiety and depression scores and improved several subscales of quality of life in the experimental group patients. It was recommended that education and follow-up programme be used for patients scheduled to undergo implantable cardioverter defibrillator implantation, starting before implantation and continuing thereafter, to help patients adapt to a life with implantable cardioverter defibrillator. Planned education and follow-up programme conducted by nurses may improve the knowledge levels and quality of life, anxiety and depression scores of the implantable cardioverter defibrillator-implanted patients. © 2013 Blackwell Publishing Ltd.

  4. Design and manufacture of customized dental implants by using reverse engineering and selective laser melting technology.

    PubMed

    Chen, Jianyu; Zhang, Zhiguang; Chen, Xianshuai; Zhang, Chunyu; Zhang, Gong; Xu, Zhewu

    2014-11-01

    Recently a new therapeutic concept of patient-specific implant dentistry has been advanced based on computer-aided design/computer-aided manufacturing technology. However, a comprehensive study of the design and 3-dimensional (3D) printing of the customized implants, their mechanical properties, and their biomechanical behavior is lacking. The purpose of this study was to evaluate the mechanical and biomechanical performance of a novel custom-made dental implant fabricated by the selective laser melting technique with simulation and in vitro experimental studies. Two types of customized implants were designed by using reverse engineering: a root-analog implant and a root-analog threaded implant. The titanium implants were printed layer by layer with the selective laser melting technique. The relative density, surface roughness, tensile properties, bend strength, and dimensional accuracy of the specimens were evaluated. Nonlinear and linear finite element analysis and experimental studies were used to investigate the stress distribution, micromotion, and primary stability of the implants. Selective laser melting 3D printing technology was able to reproduce the customized implant designs and produce high density and strength and adequate dimensional accuracy. Better stress distribution and lower maximum micromotions were observed for the root-analog threaded implant model than for the root-analog implant model. In the experimental tests, the implant stability quotient and pull-out strength of the 2 types of implants indicated that better primary stability can be obtained with a root-analog threaded implant design. Selective laser melting proved to be an efficient means of printing fully dense customized implants with high strength and sufficient dimensional accuracy. Adding the threaded characteristic to the customized root-analog threaded implant design maintained the approximate geometry of the natural root and exhibited better stress distribution and primary stability. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  5. The relative effect of surface strontium chemistry and super-hydrophilicity on the early osseointegration of moderately rough titanium surface in the rabbit femur.

    PubMed

    Park, Jin-Woo; Kwon, Tae-Geon; Suh, Jo-Young

    2013-06-01

    It is unclear whether surface bioactive chemistry or hydrophilicity plays a more dominant role in the osseointegration of micro-structured titanium implants having the same surface topography at the micrometer and submicrometer scales. To understand their comparative effect on enhancing the early osseointegration of micro-rough-surfaced implants, this study compared the bone healing-promoting effect of surface strontium (Sr) chemistry that has been shown in numerous studies to super-hydrophilicity in the early osseointegration of moderately rough-surfaced clinical oral implants (SLA(®) implant) in rabbit cancellous bone. Hydrothermal treatment was performed to incorporate Sr ions into the surface of clinical SLA implants (SLA/Sr implant). The surface characteristics were evaluated by using field emission-scanning electron microscopy, X-ray photoelectron spectroscopy and optical profilometry. Twenty screw implants (10 control and 10 experimental) were placed in the femoral condyles of 10 New Zealand White rabbits. The early osseointegration of the SLA/Sr implant was compared with a chemically modified super-hydrophilic SLA implant (SLActive(®) implant) by histomorphometric and resonance frequency analysis after 2 weeks of implantation. The SLA/Sr and SLActive implants exhibited an identical surface topography and average R(a) values at the micron and submicron scales. The SLA/Sr implant displayed a high amount of surface Sr content (15.6 at.%). There was no significant difference in the implant stability quotient (ISQ) values between the two groups. However, histomorphometric analysis revealed a significantly higher bone-to-implant contact percentage in the SLA/Sr implants compared with the SLActive implants in rabbit cancellous bone (P < 0.01). The results indicate that the surface Sr chemistry surpasses the effect of super-hydrophilicity in promoting the early bone apposition of moderately rough Ti surface in cancellous bone. © 2012 John Wiley & Sons A/S.

  6. Increased crown-to-implant ratio may not be a risk factor for dental implant failure under appropriate plaque control.

    PubMed

    Okada, Shinsuke; Koretake, Katsunori; Miyamoto, Yasunari; Oue, Hiroshi; Akagawa, Yasumasa

    2013-01-01

    The aim of this study was to evaluate whether increased crown-to-implant (C/I) ratio influences implant stability or not under proper healthy control of peri-implant mucosa. The hypothesis of this study is that implant stability can be maintained despite High C/I, under appropriate plaque control. Five male Beagle-Labrador hybrid dogs (2 years old) were used. Their bilateral mandibular premolar extraction was performed. After allowing 12 weeks for bone healing, 3 types of vertical marginal bone loss were simultaneously prepared randomly. Then, 30 titanium implants were placed in the edentulous areas and defined as High C/I, Mid C/I and Low C/I groups. This time point was designated as the baseline (0 Week). Twelve weeks after implant placement, metal superstructures were cemented to the implants and an occlusal plate was set at the opposite side. At the same time, Calcein green was injected for remodeling evaluation. Implants were loaded by feeding the dogs a hard pellet diet. Tooth brushing was performed 5 days per week during the study to maintain healthy peri-implant mucosa. Twenty-four weeks following implant placement, the interface structure was evaluated clinically, radiologically, and histologically. Implant stability quotient (ISQ) increased with time in all 3 groups, without any significant correlation with the C/I value (p >0.05). Moreover, mean marginal bone loss adjacent around implants in all 3 groups ranged between 0.11 and 0.19 mm, with no significant difference (p >0.05). Many fluorescence-labeled bones are shown in the High C/I group. It is considered that high remodeling activity prevent marginal bone loss in the High C/I group and this may provide favorable implant stability under proper plaque control. These findings suggest that increased C/I may not be a risk factor for implant failure if the peri-implant mucosa is kept healthy, as was the case in this animal model.

  7. Determining factors for implant referral rates.

    PubMed

    Levin, Roger P

    2002-01-01

    The research findings indicate that the field of implant dentistry will only grow at a moderately low level unless certain changes are made. Findings indicated that the effort by the implant companies has been nothing short of dramatic, and yet almost 60% of restorative doctors do not participate annually in any implant case. There was no clear indication that younger restorative doctors will significantly increase the number of implant referrals, as their overall implant education has not dramatically differed from those dentists who graduated in earlier years. Once the research was completed, it became obvious to Levin Group that the driving force behind implant referral growth will be implant surgeons, because of their one-to-one relationship with restorative doctors. The Levin Group Implant Management and Marketing Consulting Program is based on approaching restorative doctors in several different levels, starting with awareness all the way through to case facilitation and long-term tracking and communication. Finally, a continuing marketing/education effort needs to be consistently in place with effective materials, not only to create a high level of awareness, but also to motivate restorative doctors to refer cases and then work through the case with the implant surgeon to a satisfactory completion for the restorative doctor, implant surgeon, and patient. While the surgical insertion of implants may seem to carry a high-profit margin relative to the restoration of implants, the truth is that the restoration of implants usually provides a 40% higher profit margin for the restorative doctor than traditional dental services. One of the key issues is that referring doctors have not necessarily learned how to set fees and present cases with regard to implant dentistry. The key factor here is to ensure that the patient understands that implant services involve higher fees than traditional services, because of the necessarily higher levels of experience, education, and cost associated with implant dentistry. It is also important to emphasize to patients that the quality of life far outweighs the differential in fees.

  8. Osteointegration of PLGA implants with nanostructured or microsized β-TCP particles in a minipig model.

    PubMed

    Kulkova, Julia; Moritz, Niko; Suokas, Esa O; Strandberg, Niko; Leino, Kari A; Laitio, Timo T; Aro, Hannu T

    2014-12-01

    Bioresorbable suture anchors and interference screws have certain benefits over equivalent titanium-alloy implants. However, there is a need for compositional improvement of currently used bioresorbable implants. We hypothesized that implants made of poly(l-lactide-co-glycolide) (PLGA) compounded with nanostructured particles of beta-tricalcium phosphate (β-TCP) would induce stronger osteointegration than implants made of PLGA compounded with microsized β-TCP particles. The experimental nanostructured self-reinforced PLGA (85L:15G)/β-TCP composite was made by high-energy ball-milling. Self-reinforced microsized PLGA (95L:5G)/β-TCP composite was prepared by melt-compounding. The composites were characterized by gas chromatography, Ubbelohde viscometry, scanning electron microscopy, laser diffractometry, and standard mechanical tests. Four groups of implants were prepared for the controlled laboratory study employing a minipig animal model. Implants in the first two groups were prepared from nanostructured and microsized PLGA/β-TCP composites respectively. Microroughened titanium-alloy (Ti6Al4V) implants served as positive intra-animal control, and pure PLGA implants as negative control. Cone-shaped implants were inserted in a random order unilaterally in the anterior cortex of the femoral shaft. Eight weeks after surgery, the mechanical strength of osteointegration of the implants was measured by a push-out test. The quality of new bone surrounding the implant was assessed by microcomputed tomography and histology. Implants made of nanostructured PLGA/β-TCP composite did not show improved mechanical osteointegration compared with the implants made of microsized PLGA/β-TCP composite. In the intra-animal comparison, the push-out force of two PLGA/β-TCP composites was 35-60% of that obtained with Ti6Al4V implants. The implant materials did not result in distinct differences in quality of new bone surrounding the implant. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. pH dependent silver nanoparticles releasing titanium implant: A novel therapeutic approach to control peri-implant infection.

    PubMed

    Dong, Yiwen; Ye, Hui; Liu, Yi; Xu, Lihua; Wu, Zuosu; Hu, Xiaohui; Ma, Jianfeng; Pathak, Janak L; Liu, Jinsong; Wu, Gang

    2017-10-01

    Peri-implant infection control is crucial for implant fixation and durability. Antimicrobial administration approaches to control peri-implant infection are far from satisfactory. During bacterial infection, pH level around the peri-implant surface decreases as low as pH 5.5. This change of pH can be used as a switch to control antimicrobial drug release from the implant surface. Silver nanoparticles (AgNPs) have broad-spectrum antimicrobial properties. In this study, we aimed to design a pH-dependent AgNPs releasing titania nanotube arrays (TNT) implant for peri-implant infection control. The nanotube arrays were fabricated on the surface of titanium implant as containers; AgNPs were grafted on TNT implant surface via a low pH-sensitive acetal linker (TNT-AL-AgNPs). SEM, TEM, AFM, FTIR as well as XPS data showed that AgNPs have been successfully linked to TNT via acetal linker without affecting the physicochemical characteristics of TNT. The pH 5.5 enhanced AgNPs release from TNT-AL-AgNPs implant compared with pH 7.4. AgNPs released at pH 5.5 robustly increased antimicrobial activities against gram-positive and gram-negative bacteria compared with AgNPs released at pH 7.4. TNT-AL-AgNPs implant enhanced osteoblast proliferation, differentiation, and did not affect osteoblast morphology in vitro. In conclusion, incorporation of AgNPs in TNT via acetal linker maintained the surface characteristics of TNT. TNT-AL-AgNPs implant was biocompatible to osteoblasts and showed osteoinductive properties. AgNPs were released from TNT-AL-AgNPs implant in high dose at pH 5.5, and this release showed strong antimicrobial properties in vitro. Therefore, this novel design of low pH-triggered AgNPs releasing TNT-AL-AgNPs could be an infection-triggered antimicrobial releasing implant model to control peri-implant infection. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Comparison of marginal bone loss and implant success between axial and tilted implants in maxillary All-on-4 treatment concept rehabilitations after 5 years of follow-up.

    PubMed

    Hopp, Milena; de Araújo Nobre, Miguel; Maló, Paulo

    2017-10-01

    There is need for more scientific and clinical information on longer-term outcomes of tilted implants compared to implants inserted in an axial position. Comparison of marginal bone loss and implant success after a 5-year follow-up between axial and tilted implants inserted for full-arch maxillary rehabilitation. The retrospective clinical study included 891 patients with 3564 maxillary implants rehabilitated according to the All-on-4 treatment concept. The follow-up time was 5 years. Linear mixed-effect models were performed to analyze the influence of implant orientation (axial/tilted) on marginal bone loss and binary logistic regression to assess the effect of patient characteristics on occurrence of marginal bone loss >2.8 mm. Only those patients with measurements of at least one axial and one tilted implant available were analyzed. This resulted in a data set of 2379 implants (1201 axial, 1178 tilted) in 626 patients (=reduced data set). Axial and tilted implants showed comparable mean marginal bone losses of 1.14 ± 0.71 and 1.19 ± 0.82 mm, respectively. Mixed model analysis indicated that marginal bone loss levels at 5 years follow up was not significantly affected by the orientation (axial/tilted) of the implants in the maxillary bone. Smoking and female gender were associated with marginal bone loss >2.8 mm in a logistic regression analysis. Five-year implant success rates were 96%. The occurrence of implant failure showed to be statistically independent from orientation. Within the limitations of this study and considering a follow-up time of 5 years, it can be concluded that tilted implants behave similarly with regards to marginal bone loss and implant success in comparison to axial implants in full-arch rehabilitation of the maxilla. Longer-term outcomes (10 years +) are needed to verify this result. © 2017 Wiley Periodicals, Inc.

  11. A 5-year randomized trial to compare 1 or 2 implants for implant overdentures.

    PubMed

    Bryant, S R; Walton, J N; MacEntee, M I

    2015-01-01

    The hypothesis of this 5-y randomized clinical trial was that there would be no significant difference in the satisfaction of edentulous participants with removable complete overdentures attached to 1 or 2 mandibular implants. Secondary aims were to test changes in satisfaction between and within the groups from baseline to 5 y and differences between the groups in implant survival and prosthodontic maintenance over 5 y. Each of the 86 participants (mean age, 67 y) was randomly allocated to receive either 1 implant in the midline (group 1) or 2 implants in the canine areas (group 2) attached to a mandibular overdenture opposing a maxillary complete denture. Satisfaction was self-assessed by participants on a visual analog scale at baseline prior to implants, as well as at 2 mo and 1, 3, and 5 y with implant overdentures, whereas implant survival and prosthodontic maintenance were assessed by clinical examination. After 5 y, 29 participants in group 1 and 33 in group 2 were available, with most dropouts due to death. Satisfaction with the implant denture after 5 y was significantly (P < 0.001) higher than at baseline in both groups and remained with no significant difference (P = 0.32) between the groups. No implants failed in group 1 but 5 failed before loading in 4 participants in group 2. Most participants required maintenance or occasionally denture replacement, and although differences between the groups were not statistically significant, group 1 experienced almost twice as many fractured dentures usually adjacent to the implant attachment. We conclude that there were no significant differences after 5 y in satisfaction or survival of implants with mandibular overdentures retained by 1 implant or 2 implants. Additional research is required to confirm long-term treatment effectiveness of single-implant dentures and the implications of prosthetic maintenance with implant overdentures (ClinicalTrials.gov: NCT02117856). © International & American Associations for Dental Research 2014.

  12. Systemic Assessment of Patients Undergoing Dental Implant Surgeries: A Trans- and Post-operative Analysis.

    PubMed

    Byakodi, Sanjay; Kumar, Sachin; Reddy, Rajesh Kumar; Kumar, Vipin; Sepolia, Shipra; Gupta, Shivangi; Singh, Harkanwal Preet

    2017-01-01

    Procedure-related and patient-related factors influence the prognosis of dental implants to a major extent. Hence, we aimed to evaluate and analyze various systemic factors in patients receiving dental implants. Fifty-one patients were included in the study, in which a total of 110 dental implants were placed. Complete examination of the subjects was done before and after placement of dental implants. Implant surgery was planned, and osseointegrated dental implants were placed in the subjects. Postoperative evaluation of the dental implant patients was done after 3 weeks. Anxiety levels were determined using State-Trait Anxiety Inventory (STAI) questionnaire on the surgery day and after 1 week of surgery. The participant describes how they feel at the moment by responding to twenty items as follows: (1) absolutely not, (2) slightly, (3) somewhat, or (4) very much. All the results were recorded and statistical analyzed by SPSS software. Out of 51, 29 patients were males while 22 were females, with ratio of 1.32:1. Female patients' mean age was 50.18 years while male patients' mean age was 52.71 years, with statistically nonsignificant difference between them. Functional rehabilitation was the main purpose of choosing dental implants in more than 90% of the subjects. Diameter of 3.75 mm was the shortest implants to be placed in the present study, whereas in terms of length, 8.5 mm was the shortest length of dental implant used in the present study. Tooth area in which maximum implants were placed in our study was 36 tooth region. Maximum implants were placed in Type II bone quality ( n = 38). Implants installed in the mandible were clamped more efficiently than implants placed in the maxilla ( P < 0.001). The difference of average STAI-State subscore before and after the surgery was statistically significant ( P < 0.05; significant). Mandibular dental implants show more clamping (torque) than maxillary dental implants.

  13. Influence of the Diameter of Dental Implants Replacing Single Molars: 3- to 6-Year Follow-Up.

    PubMed

    Mendonça, Jose Alfredo; Senna, Plinio Mendes; Francischone, Carlos Eduardo; Francischone Junior, Carlos Eduardo; Sotto-Maior, Bruno Salles

    The aim of this study was to evaluate the influence of the implant diameter on marginal bone remodeling around dental implants replacing single molars after a follow-up period of 3 to 6 years. Patients who received dental implants with an external hexagon platform in healed sites to support a single metal-ceramic crown in the molar region were recalled to the office. The implantation sites and implant length information were recorded, and the implants were divided according to the implant diameter: regular (RP) or wide (WP). Each implant was assessed by digital periapical radiography, using a sensor holder for the paralleling technique. The marginal bone remodeling was determined as the distance from the implant platform to the first bone-to-implant contact, and the known implant length was used to calibrate the images in the computer software. The follow-up measurements were compared with those obtained from the radiograph taken at the time of prosthetic loading to determine the late bone remodeling. The independent t test was used to compare data. A total of 67 implants from 46 patients were evaluated with a mean follow-up period of 4.5 ± 1.0 years. The RP group comprised 36 implants from 29 patients (mean age: 58.3 ± 10.6 years), while 31 implants from 17 patients (mean age: 56.9 ± 11.5 years) were included in the WP group. The RP group presented lower survival rates (86.1%) than the WP group (100.0%). Similar marginal bone loss (P < .05) was identified for the RP and WP groups (1.35 ± 0.96 mm and 1.06 ± 0.70 mm, respectively). Although wide-diameter implants exhibited lower incidence failures, the bone levels were similar after the prosthetic loading around regular- and wide-diameter implants supporting single molar crowns.

  14. Current trends in dental implants

    PubMed Central

    Gaviria, Laura; Salcido, John Paul; Guda, Teja

    2014-01-01

    Tooth loss is very a very common problem; therefore, the use of dental implants is also a common practice. Although research on dental implant designs, materials and techniques has increased in the past few years and is expected to expand in the future, there is still a lot of work involved in the use of better biomaterials, implant design, surface modification and functionalization of surfaces to improve the long-term outcomes of the treatment. This paper provides a brief history and evolution of dental implants. It also describes the types of implants that have been developed, and the parameters that are presently used in the design of dental implants. Finally, it describes the trends that are employed to improve dental implant surfaces, and current technologies used for the analysis and design of the implants. PMID:24868501

  15. Effect of surface chemistry on the rate of osseointegration of sintered porous-surfaced Ti-6Al-4V implants.

    PubMed

    Taché, Alex; Gan, Lu; Deporter, Douglas; Pilliar, Robert M

    2004-01-01

    The effect of adding a thin sol-gel-formed calcium phosphate (CaP) coating to sintered porous-surfaced titanium alloy (Ti-6Al-4V) implants on rates of initial bone ingrowth was investigated. Control implants (as manufactured) and similar implants with sol-gel CaP coatings were randomly placed in distal femoral rabbit condyles (1 implant/leg). After healing for 6, 9, 12, and 16 days, 8 of 10 rabbits in each time group were assessed for maximum implant pullout force (N) and interface stiffness (N/mm). Selected extracted implants also were examined by secondary electron imaging to characterize affected surfaces. The implants of the remaining 2 rabbits in each group were examined by backscattered scanning electron microscopy (BSEM). Significantly greater pullout forces and interface stiffness were found for CaP-coated implants at 6 and 9 days. At 6 days, BSEM revealed bone ingrowth on CaP-coated implants but not on control implants. Secondary electron imaging and BSEM observations also suggested greater bone ingrowth with CaP-coated porous implants at 9, 12, and 16 days. Sol-gel-formed CaP surface films significantly enhance rates of bone ingrowth into sintered porous-surfaced implants. This surface treatment may have a number of clinical benefits, including shortening the period prior to functional loading of such implants and improving treatment outcomes in situations of poor bone quality and/or quantity. (More than 50 references).

  16. Multivariate linear regression analysis to identify general factors for quantitative predictions of implant stability quotient values

    PubMed Central

    Huang, Hairong; Xu, Zanzan; Shao, Xianhong; Wismeijer, Daniel; Sun, Ping; Wang, Jingxiao

    2017-01-01

    Objectives This study identified potential general influencing factors for a mathematical prediction of implant stability quotient (ISQ) values in clinical practice. Methods We collected the ISQ values of 557 implants from 2 different brands (SICace and Osstem) placed by 2 surgeons in 336 patients. Surgeon 1 placed 329 SICace implants, and surgeon 2 placed 113 SICace implants and 115 Osstem implants. ISQ measurements were taken at T1 (immediately after implant placement) and T2 (before dental restoration). A multivariate linear regression model was used to analyze the influence of the following 11 candidate factors for stability prediction: sex, age, maxillary/mandibular location, bone type, immediate/delayed implantation, bone grafting, insertion torque, I-stage or II-stage healing pattern, implant diameter, implant length and T1-T2 time interval. Results The need for bone grafting as a predictor significantly influenced ISQ values in all three groups at T1 (weight coefficients ranging from -4 to -5). In contrast, implant diameter consistently influenced the ISQ values in all three groups at T2 (weight coefficients ranging from 3.4 to 4.2). Other factors, such as sex, age, I/II-stage implantation and bone type, did not significantly influence ISQ values at T2, and implant length did not significantly influence ISQ values at T1 or T2. Conclusions These findings provide a rational basis for mathematical models to quantitatively predict the ISQ values of implants in clinical practice. PMID:29084260

  17. Two Bilateral Zygomatic Implants Placed and Immediately Loaded: A Retrospective Chart Review with Up-to-54-Month Follow-up.

    PubMed

    Neugarten, Jay; Tuminelli, Frank J; Walter, Leora

    To report on the outcome of placement of two bilateral zygomatic implants with an immediately loaded prosthesis. A retrospective chart review was conducted of all patients treated with zygomatic implants between August 1, 2011 and June 6, 2016. All patients had at least two zygomatic implants placed bilaterally and immediately loaded with a provisional prosthesis the same day of implant placement. The implants were Nobel Biocare TiUnite or machined surface with lengths of 30 to 52.5 mm. All patients were treated by a team consisting of one surgeon, a restorative dentist or prosthodontist, an anesthesiologist, and a laboratory technician. Implant success was defined as successful integration of the implant; prosthetic success was defined as retention of the prosthesis under normal function. One hundred five zygomatic implants were placed and immediately loaded in 28 patients over a period of 1 to 60 months. Ages ranged from 46 to 81 years, with 26 female and 2 male patients. All the implants were placed by one surgeon. The immediate load on the day of implant placement was completed by either one of 2 prosthodontists or 11 restorative dentists. Implant success was 96% (101/105). All four failed implants were in one patient and were TiUnite surface coated. This study demonstrated that two zygomatic implants bilaterally placed and immediately loaded with a full-arch splinted prosthesis will provide a predictable outcome.

  18. Displacement of dental implants in trabecular bone under a static lateral load in fresh bovine bone.

    PubMed

    Engelke, Wilfried; Müller, Alois; Decco, Oscar A; Rau, María J; Cura, Andrea C; Ruscio, Mara L; Knösel, Michael

    2013-04-01

    The study aims to provide objective data for the displacement of titanium screw implants in trabecular bone specimens. One hundred Semados implants (Bego, Bremen, Germany) were inserted in bovine type IV bone specimens. All implants had a diameter of 3.75 mm; 50 implants had a length of 8.5 mm and 50 implants had a length of 15 mm. Insertion torque was determined at intervals of 10, 20, and 30 Ncm. Implants were loaded horizontally with 10, 20, and 30 N for 2 seconds. An indicator strip was attached to the implant abutment to allow direct observation of implant movement relative to the bone surface. Horizontal displacement was assessed with an accuracy of measurement of 10 µm. Seven implants got lost by visible loosening. Degree of displacement was subject to evaluation with all others. Those implants showed a mean displacement of 59 µm for 10 N (n = 100), 173 µm for 20 N (n = 99), and 211 µm for 30 N (n = 93). The mean displacement of 15-mm implants (16, 37, 51 µm) was significantly lower compared with 8.5-mm implants (103, 311, 396 µm) corresponding to 10, 20, and 30 N as lateral loads. Displacement of screw implants in trabecular bone can be detected and visualized using commercially available endoscopes with a high magnification. A lateral load of 20 N indicates a mean displacement of over 100 µm and therefore results in a critical displacement. © 2011 Wiley Periodicals, Inc.

  19. Implant dentistry curriculum in undergraduate education: part 2-program at the Albert-Ludwigs University, Freiburg, Germany.

    PubMed

    Kroeplin, Birgit S; Strub, Joerg R

    2011-01-01

    The aim of this study was to describe the didactic and clinical undergraduate implant dentistry program of the Albert-Ludwigs University, Freiburg, Germany, with emphasis on the clinical implant experience. A detailed description of the implant curriculum at Albert-Ludwigs University is given with documented exemplary cases and additional flow charts. All students participate in 28 hours of lectures and approximately 64 hours of seminars with hands-on courses and gain clinical experience. All undergraduate students are eligible to place and restore oral implants. Emphasis is placed on prosthetic-driven planning of implant positions, three-dimensional imaging, and computer-guided implant placement. Implant restorations performed by undergraduate students comprise single crowns and small multiunit fixed dental prostheses in partially edentulous posterior maxillae and anterior or posterior mandibles, implant-retained overdentures (snap attachment) in edentulous patients, and telescopic fixed-removable dental prostheses on remaining teeth and strategically placed additional implants. Over the past 2.5 years, 51 patients were treated with 97 dental implants placed by students in the undergraduate program. Seventy-one restorations were inserted: 60.6% single crowns, 7% fixed dental protheses, 21.1% overdentures, and 11.3% telescopic fixed-removable dental prostheses. The implant survival rate was 98.9%. Because survival rates for dental implants placed and restored by students are comparable to those of experienced dentists, oral implant dentistry should be implemented as part of the undergraduate dental curriculum.

  20. Prevalence of peri-implantitis in patients with implant-supported fixed prostheses.

    PubMed

    Schuldt Filho, Guenther; Dalago, Haline Renata; Oliveira de Souza, João Gustavo; Stanley, Kyle; Jovanovic, Sascha; Bianchini, Marco Aurélio

    2014-01-01

    The purpose of this study was to evaluate periimplantitis prevalence in patients using implant-supported fixed prostheses that did not have any routine maintenance care. A total of 161 implants (27 patients) were evaluated in patients using implant-supported fixed prostheses. Collected data included information related to patient general health and local factors such as characteristics of implants, time in function, type of loading, positioning, Modified Bleeding Index, bacterial plaque, bleeding on probing (BOP), marginal recession, probing depth (PD), keratinized mucosa, and radiographic bone loss (BL). Factors related to the prostheses were also evaluated. The exclusion criteria were patients that have had any follow-up visit for plaque control of the prosthesis and/or the implants. From a total of 161 implants, 116 (72%) presented without peri-implantitis (PD > 4 mm + BOP + BL > 2 mm) while 45 (28%) had some sign of the disease. Implants placed in the maxilla were 2.98 times more likely to develop the disease (P < .05). Moreover, patients aged ≤ 60 years old were 3.24 times more likely to develop peri-implantitis (P < .05). Another analysis with statistical relevance (P < .05) was that implants with less than 3 mm interimplant distance were three times more likely to have peri-implantitis. There was no statistical relevance considering other analyses. It can be concluded that patients aged ≤ 60 years have a greater chance of presenting periimplantitis, as well as for implants positioned in the maxilla and those placed with an interimplant distance < 3 mm.

Top