NASA Astrophysics Data System (ADS)
Meng, Hao; Wang, Zhongyu; Fu, Jihua
2008-12-01
The non-diffracting beam triangulation measurement system possesses the advantages of longer measurement range, higher theoretical measurement accuracy and higher resolution over the traditional laser triangulation measurement system. Unfortunately the measurement accuracy of the system is greatly degraded due to the speckle noise, the CCD photoelectric noise and the background light noise in practical applications. Hence, some effective signal processing methods must be applied to improve the measurement accuracy. In this paper a novel effective method for removing the noises in the non-diffracting beam triangulation measurement system is proposed. In the method the grey system theory is used to process and reconstruct the measurement signal. Through implementing the grey dynamic filtering based on the dynamic GM(1,1), the noises can be effectively removed from the primary measurement data and the measurement accuracy of the system can be improved as a result.
Health Systems and Their Assessment: A Methodological Proposal of the Synthetic Outcome Measure
Romaniuk, Piotr; Kaczmarek, Krzysztof; Syrkiewicz-Świtała, Magdalena; Holecki, Tomasz; Szromek, Adam R.
2018-01-01
The effectiveness of health systems is an area of constant interest for public health researchers and practitioners. The varied approach to effectiveness itself has resulted in numerous methodological proposals related to its measurement. The limitations of the currently used methods lead to a constant search for better tools for the assessment of health systems. This article shows the possibilities of using the health system synthetic outcome measure (SOM) for this purpose. It is an original tool using 41 indicators referring to the epidemiological situation, health behaviors, and factors related to the health-care system, which allows a relatively quick and easy assessment of the health system in terms of its effectiveness. Construction of the measure of health system functioning in such a way allowed its presentation in dynamic perspective, i.e., assessing not only the health system itself in a given moment of time but also changes in the value of the effectiveness measures. In order to demonstrate the cognitive value of the SOM, the analysis of the effectiveness of health systems in 21 countries of Central and Eastern Europe during the transformation period was carried out. The mean SOM values calculated on the basis of the component measures allowed to differentiate countries in terms of the effectiveness of their health systems. Considering the whole period, a similar level of health system effects can be observed in Slovenia, Croatia, Czech Republic, Slovakia, Poland, Macedonia, and Albania. In the middle group, Hungary, Romania, Latvia, Lithuania, Georgia, Estonia, Bulgaria, Belarus, and Armenia were found. The third group, weakest in terms of achieved effects, was formed by health systems in countries like Ukraine, Moldova, and Russia. The presented method allows for the analysis of the health system outcomes from a comparative angle, eliminating arbitrariness of pinpointing a model solution as a potential reference point in the assessment of the systems. The measure, with the use of additional statistical tools to establish correlations with elements of the external and internal environment of a health system, allows for conducting analyses of conditions for differences in the effects of health system operation and circumstances for the effectiveness of reform processes.
Health Systems and Their Assessment: A Methodological Proposal of the Synthetic Outcome Measure.
Romaniuk, Piotr; Kaczmarek, Krzysztof; Syrkiewicz-Świtała, Magdalena; Holecki, Tomasz; Szromek, Adam R
2018-01-01
The effectiveness of health systems is an area of constant interest for public health researchers and practitioners. The varied approach to effectiveness itself has resulted in numerous methodological proposals related to its measurement. The limitations of the currently used methods lead to a constant search for better tools for the assessment of health systems. This article shows the possibilities of using the health system synthetic outcome measure (SOM) for this purpose. It is an original tool using 41 indicators referring to the epidemiological situation, health behaviors, and factors related to the health-care system, which allows a relatively quick and easy assessment of the health system in terms of its effectiveness. Construction of the measure of health system functioning in such a way allowed its presentation in dynamic perspective, i.e., assessing not only the health system itself in a given moment of time but also changes in the value of the effectiveness measures. In order to demonstrate the cognitive value of the SOM, the analysis of the effectiveness of health systems in 21 countries of Central and Eastern Europe during the transformation period was carried out. The mean SOM values calculated on the basis of the component measures allowed to differentiate countries in terms of the effectiveness of their health systems. Considering the whole period, a similar level of health system effects can be observed in Slovenia, Croatia, Czech Republic, Slovakia, Poland, Macedonia, and Albania. In the middle group, Hungary, Romania, Latvia, Lithuania, Georgia, Estonia, Bulgaria, Belarus, and Armenia were found. The third group, weakest in terms of achieved effects, was formed by health systems in countries like Ukraine, Moldova, and Russia. The presented method allows for the analysis of the health system outcomes from a comparative angle, eliminating arbitrariness of pinpointing a model solution as a potential reference point in the assessment of the systems. The measure, with the use of additional statistical tools to establish correlations with elements of the external and internal environment of a health system, allows for conducting analyses of conditions for differences in the effects of health system operation and circumstances for the effectiveness of reform processes.
Effects of automobile steering characteristics on driver vehicle system dynamics in regulation tasks
NASA Technical Reports Server (NTRS)
Mcruer, D. T.; Klein, R.
1975-01-01
A regulation task which subjected the automobile to a random gust disturbance which is countered by driver control action is used to study the effects of various automobile steering characteristics on the driver/vehicle system. The experiments used a variable stability automobile specially configured to permit insertion of the simulated gust disturbance and the measurement of the driver/vehicle system characteristics. Driver/vehicle system dynamics were measured and interpreted as an effective open loop system describing function. Objective measures of system bandwidth, stability, and time delays were deduced and compared. These objective measures were supplemented by driver ratings. A tentative optimum range of vehicle dynamics for the directional regulation task was established.
NASA Astrophysics Data System (ADS)
Xiong, Xingting; Qu, Xinghua; Zhang, Fumin
2018-01-01
We propose and describe a novel multi-dimensional absolute distance measurement system. This system incorporates a basic frequency modulated continuous wave (FMCW) radar and an second external cavity laser (ECL). Through the use of trilateration, the system in our paper can provide 3D resolution inherently range. However, the measured optical path length differences (OPD) is often variable in industrial environments and this will causes Doppler effect, which has greatly impact on the measurement result. With using the second ECL, the system can correct the Doppler effect to ensure the precision of absolute distance measurement. Result of the simulation will prove the influence of Doppler effect.
Automated acoustic intensity measurements and the effect of gear tooth profile on noise
NASA Technical Reports Server (NTRS)
Atherton, William J.; Pintz, Adam; Lewicki, David G.
1987-01-01
Acoustic intensity measurements were made at NASA Lewis Research Center on a spur gear test apparatus. The measurements were obtained with the Robotic Acoustic Intensity Measurement System developed by Cleveland State University. This system provided dense spatial positioning, and was calibrated against a high quality acoustic intensity system. The measured gear noise compared gearsets having two different tooth profiles. The tests evaluated the sound field of the different gears for two speeds and three loads. The experimental results showed that gear tooth profile had a major effect on measured noise. Load and speed were found to have an effect on noise also.
Models and techniques for evaluating the effectiveness of aircraft computing systems
NASA Technical Reports Server (NTRS)
Meyer, J. F.
1982-01-01
Models, measures, and techniques for evaluating the effectiveness of aircraft computing systems were developed. By "effectiveness" in this context we mean the extent to which the user, i.e., a commercial air carrier, may expect to benefit from the computational tasks accomplished by a computing system in the environment of an advanced commercial aircraft. Thus, the concept of effectiveness involves aspects of system performance, reliability, and worth (value, benefit) which are appropriately integrated in the process of evaluating system effectiveness. Specifically, the primary objectives are: the development of system models that provide a basis for the formulation and evaluation of aircraft computer system effectiveness, the formulation of quantitative measures of system effectiveness, and the development of analytic and simulation techniques for evaluating the effectiveness of a proposed or existing aircraft computer.
Noninvasive Quantum Measurement of Arbitrary Operator Order by Engineered Non-Markovian Detectors
NASA Astrophysics Data System (ADS)
Bülte, Johannes; Bednorz, Adam; Bruder, Christoph; Belzig, Wolfgang
2018-04-01
The development of solid-state quantum technologies requires the understanding of quantum measurements in interacting, nonisolated quantum systems. In general, a permanent coupling of detectors to a quantum system leads to memory effects that have to be taken into account in interpreting the measurement results. We analyze a generic setup of two detectors coupled to a quantum system and derive a compact formula in the weak-measurement limit that interpolates between an instantaneous (text-book type) and almost continuous—detector dynamics-dependent—measurement. A quantum memory effect that we term "system-mediated detector-detector interaction" is crucial to observe noncommuting observables simultaneously. Finally, we propose a mesoscopic double-dot detector setup in which the memory effect is tunable and that can be used to explore the transition to non-Markovian quantum measurements experimentally.
Establishing System Measures of Effectiveness
2001-03-01
Halpin, 1991] Andriole, Stephen J. and Stanley M. Halpin, editors. Information Technology for Command and Control: Methods and Tools for Systems...Systems with Models and Objects, New York: Mc Graw -Hill, 1997. [Pawlowski, 1993a] Pawlowski, Thomas J. III, LTC. C3IEW Measures of Effectiveness
The study of stereo vision technique for the autonomous vehicle
NASA Astrophysics Data System (ADS)
Li, Pei; Wang, Xi; Wang, Jiang-feng
2015-08-01
The stereo vision technology by two or more cameras could recovery 3D information of the field of view. This technology can effectively help the autonomous navigation system of unmanned vehicle to judge the pavement conditions within the field of view, and to measure the obstacles on the road. In this paper, the stereo vision technology in measuring the avoidance of the autonomous vehicle is studied and the key techniques are analyzed and discussed. The system hardware of the system is built and the software is debugged, and finally the measurement effect is explained by the measured data. Experiments show that the 3D reconstruction, within the field of view, can be rebuilt by the stereo vision technology effectively, and provide the basis for pavement condition judgment. Compared with unmanned vehicle navigation radar used in measuring system, the stereo vision system has the advantages of low cost, distance and so on, it has a good application prospect.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., measurements that demonstrate the effectiveness of the system in controlling exposure, such as capture velocity...) Measurements of the system's effectiveness in controlling exposure shall be made as necessary within five... recirculated into the workplace, the system shall have a high efficiency filter and be monitored to assure...
More than a score: a qualitative study of ancillary benefits of performance measurement.
Powell, Adam A; White, Katie M; Partin, Melissa R; Halek, Krysten; Hysong, Sylvia J; Zarling, Edwin; Kirsh, Susan R; Bloomfield, Hanna E
2014-08-01
Prior research has examined clinical effects of performance measurement systems. To the extent that non-clinical effects have been researched, the focus has been on negative unintended consequences. Yet, these same systems may also have ancillary benefits for patients and providers--that is, benefits that extend beyond improvements on clinical measures. The purpose of this study is to identify and describe potential ancillary benefits of performance measures as perceived by primary care staff and facility leaders in a large US healthcare system. In-person individual semistructured interviews were conducted with 59 primary care staff and facility leaders at four Veterans Health Administration facilities. Transcribed interviews were coded and organised into thematic categories. Interviewed staff observed that local performance measurement implementation practices can result in increased patient knowledge and motivation. These effects on patients can lead to improved performance scores and additional ancillary benefits. Performance measurement implementation can also directly result in ancillary benefits for the patients and providers. Patients may experience greater satisfaction with care and psychosocial benefits associated with increased provider-patient communication. Ancillary benefits of performance measurement for providers include increased pride in individual or organisational performance and greater confidence that one's practice is grounded in evidence-based medicine. A comprehensive understanding of the effects of performance measurement systems needs to incorporate ancillary benefits as well as effects on clinical performance scores and negative unintended consequences. Although clinical performance has been the focus of most evaluations of performance measurement to date, both patient care and provider satisfaction may improve more rapidly if all three categories of effects are considered when designing and evaluating performance measurement systems. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
A speech pronunciation practice system for speech-impaired children: A study to measure its success.
Salim, Siti Salwah; Mustafa, Mumtaz Begum Binti Peer; Asemi, Adeleh; Ahmad, Azila; Mohamed, Noraini; Ghazali, Kamila Binti
2016-09-01
The speech pronunciation practice (SPP) system enables children with speech impairments to practise and improve their speech pronunciation. However, little is known about the surrogate measures of the SPP system. This research aims to measure the success and effectiveness of the SPP system using three surrogate measures: usage (frequency of use), performance (recognition accuracy) and satisfaction (children's subjective reactions), and how these measures are aligned with the success of the SPP system, as well as to each other. We have measured the absolute change in the word error rate (WER) between the pre- and post-training, using the ANOVA test. Correlation co-efficiency (CC) analysis was conducted to test the relation between the surrogate measures, while a Structural Equation Model (SEM) was used to investigate the causal relations between the measures. The CC test results indicate a positive correlation between the surrogate measures. The SEM supports all the proposed gtheses. The ANOVA results indicate that SPP is effective in reducing the WER of impaired speech. The SPP system is an effective assistive tool, especially for high levels of severity. We found that performance is a mediator of the relation between "usage" and "satisfaction". Copyright © 2016 Elsevier Ltd. All rights reserved.
Marvin Nyborg
1976-01-01
This paper deals with problems of measuring acidity in rainfall and the interpretation of these measurements in terms of effects on the soil-plant system. Theoretical relationships of the carbon-dioxide-bicarbonate equalibria and its effect on rainfall acidity measurements are given. The relationship of a cation-anion balance model of acidity in rainfall to plant...
Midterm Stability Evaluation of Wide-area Power System by using Synchronized Phasor Measurements
NASA Astrophysics Data System (ADS)
Ota, Yutaka; Ukai, Hiroyuki; Nakamura, Koichi; Fujita, Hideki
In recent years, the PMU (Phasor Measurement Unit) receives a great deal of attention as a synchronized measurement system of power systems. Synchronized phasor angles obtained by the PMU provide the effective information for evaluating the stability of a bulk power system. The aspect of instability phenomena during midterm tends to be more complicated, and the stability analysis using the synchronized phasor measurements is significant in order to keep a complicated power system stable. This paper proposes a midterm stability evaluation method of the wide-area power system by using the synchronized phasor measurements. By clustering and aggregating the power system to some coherent groups, the step-out is effectively predicted on the basis of the two-machine equivalent power system model. The midterm stability of a longitudinal power system model of Japanese 60Hz systems constructed by the PSA, which is a hybrid-type power system simulator, is practically evaluated using the proposed method.
Otieno, George Ochieng; Hinako, Toyama; Motohiro, Asonuma; Daisuke, Koide; Keiko, Naitoh
2008-10-01
Many hospitals are currently in the process of developing and implementing electronic medical records (EMR) systems. This is a critical time for developing a framework that can measure and allow for comparison the effectiveness of EMR systems across hospitals that have implemented these systems. The motivation for this study comes from the realization that there is limited research on the understanding of the effectiveness of EMR systems, and a lack of appropriate reference theoretical framework for measuring the effectiveness of EMR systems. In this paper, we propose a conceptual framework for generating a composite index (CI) for measuring the effectiveness of EMR systems in hospitals. Data used to test the framework and associated research objectives were derived from a cross-sectional survey of five stakeholders of EMR systems including chief medical officers, chief nursing officers, chief information officers, doctors and nurses in 20 Japanese hospitals. Using statistical means of standardization and principal component analysis (PCA) procedure, CI was developed by summing up the scores of four dimensions-system quality, information quality, use and user satisfaction. The process included formulating items for each dimension, condensing the data into factors relevant to the dimension and calculating the CI by summing up the product of each dimension with its respective principal component score coefficient. The Cronbach's alpha for the four dimensions used in developing CI was .843. Validation of CI revealed that it was correlated to internal dimensions (system quality, R=.828; information quality, R=.909; use, R=.969; and user satisfaction, R=.679) and to external factors (JAHIS level, R=.832 and patient safety culture, R=.585). These results suggest that CI could be a reliable and valid measure of the effectiveness of EMR systems in the responding hospitals. On benchmarking of hospitals, 30.0% (6/20) of the responding hospitals performed less than satisfactory on CI and that majority of the hospitals performed poorly on user satisfaction. CI has provided a standard way, through quantitative means, of measuring, comparing and categorizing the effectiveness of EMR systems in hospitals. CI can be a powerful tool for benchmarking the effectiveness of EMR systems in hospitals in ways that can guide hospitals in computerization process as well as benchmark their systems against other hospitals.
Models and techniques for evaluating the effectiveness of aircraft computing systems
NASA Technical Reports Server (NTRS)
Meyer, J. F.
1977-01-01
Models, measures and techniques were developed for evaluating the effectiveness of aircraft computing systems. The concept of effectiveness involves aspects of system performance, reliability and worth. Specifically done was a detailed development of model hierarchy at mission, functional task, and computational task levels. An appropriate class of stochastic models was investigated which served as bottom level models in the hierarchial scheme. A unified measure of effectiveness called 'performability' was defined and formulated.
Doppler and range determination for deep space vehicles using active optical transponders.
Kinman, P W; Gagliardi, R M
1988-11-01
This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.
Doppler and range determination for deep space vehicles using active optical transponders
NASA Technical Reports Server (NTRS)
Kinman, Peter W.; Gagliardi, Robert M.
1988-01-01
This paper describes and analyzes two types of laser system employing active transponders that could accurately determine Doppler and range to deep space vehicles from earth-orbiting satellites. The first is a noncoherent optical system in which the Doppler effect on an intensity-modulating subcarrier is measured. The second is a coherent optical system in which the Doppler effect of the optical carrier itself is measured. Doppler and range measurement errors are mathematically modeled and, for three example systems, numerically evaluated.
Building a generalized distributed system model
NASA Technical Reports Server (NTRS)
Mukkamala, Ravi
1991-01-01
A number of topics related to building a generalized distributed system model are discussed. The effects of distributed database modeling on evaluation of transaction rollbacks, the measurement of effects of distributed database models on transaction availability measures, and a performance analysis of static locking in replicated distributed database systems are covered.
Wang, Ke; Zhang, Jieming; Wei, Yi-Ming
2017-05-01
The trend toward a more fiercely competitive and strictly environmentally regulated electricity market in several countries, including China has led to efforts by both industry and government to develop advanced performance evaluation models that adapt to new evaluation requirements. Traditional operational and environmental efficiency measures do not fully consider the influence of market competition and environmental regulations and, thus, are not sufficient for the thermal power industry to evaluate its operational performance with respect to specific marketing goals (operational effectiveness) and its environmental performance with respect to specific emissions reduction targets (environmental effectiveness). As a complement to an operational efficiency measure, an operational effectiveness measure not only reflects the capacity of an electricity production system to increase its electricity generation through the improvement of operational efficiency, but it also reflects the system's capability to adjust its electricity generation activities to match electricity demand. In addition, as a complement to an environmental efficiency measure, an environmental effectiveness measure not only reflects the capacity of an electricity production system to decrease its pollutant emissions through the improvement of environmental efficiency, but it also reflects the system's capability to adjust its emissions abatement activities to fulfill environmental regulations. Furthermore, an environmental effectiveness measure helps the government regulator to verify the rationality of its emissions reduction targets assigned to the thermal power industry. Several newly developed effectiveness measurements based on data envelopment analysis (DEA) were utilized in this study to evaluate the operational and environmental performance of the thermal power industry in China during 2006-2013. Both efficiency and effectiveness were evaluated from the three perspectives of operational, environmental, and joint adjustments to each electricity production system. The operational and environmental performance changes over time were also captured through an effectiveness measure based on the global Malmquist productivity index. Our empirical results indicated that the performance of China's thermal power industry experienced significant progress during the study period and that policies regarding the development and regulation of the thermal power industry yielded the expected effects. However, the emissions reduction targets assigned to China's thermal power industry are loose and conservative. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Jamróz, Paweł; Ligęza, Paweł; Socha, Katarzyna
2012-12-01
The use of measurement apparatus under conditions which differ significantly from those under which the apparatus was adjusted carries the risk of altering the previously determined measurement characteristics. This is of special concern in the case of apparatus which is sensitive to external measurement conditions. Advanced measurement systems are equipped with algorithms which allow the negative effect of unstable environmental conditions on their static characteristics to be compensated for. Meanwhile, the problem of altered dynamic properties of such systems is often neglected. This paper presents a model study in which the effect of variable operational conditions on dynamic response of hot-wire anemometric measurement system in the case of simulated mine flows was investigated. A mathematical model of measurement system able to compensate the negative effect of changes in flow velocity and configuration of measurement apparatus itself on its dynamic properties was developed and investigated. Based on conducted experiments, we have developed an automatic regulation algorithm enabling the transmission band of measurement apparatus to be optimized for measurement conditions prevailing in mine environment.
E.M.I Effects of Cathodic Protection on Electromagnetic Flowmeters
Gundogdu, Serdar; Sahin, Ozge
2007-01-01
Electromagnetic flowmeters are used to measure the speed of water flow in water distribution systems. Corrosion problem in metal pipelines can be solved by cathodic protection methods. This paper presents a research on corruptive effects of the cathodic protection system on electromagnetic flowmeter depending on its measuring principle. Experimental measurements are realized on the water distribution pipelines of the Izmir Municipality, Department of Water and Drainage Administration (IZSU) in Turkey and measurement results are given. Experimental results proved that the values measured by the electromagnetic flowmeter (EMF) are affected by cathodic protection system current. Comments on the measurement results are made and precautions to be taken are proposed.
Effects of direction of rotation in continuous and discontinuous 8 hour shift systems
Tucker, P.; Smith, L.; Macdonald, I.; Folkard, S.
2000-01-01
OBJECTIVES—Previous research has produced conflicting evidence on the relative merits of advancing and delaying shift systems. The current study assessed the effects of the direction of shift rotation within 8 hour systems, upon a range of measures including sleep, on shift alertness, physical health, and psychological wellbeing. METHODS—An abridged version of the standard shiftwork index which included retrospective alertness ratings was completed by four groups of industrial shiftworkers on relatively rapidly rotating 8 hour systems (n=611). Two groups worked continuous systems that were either advancing or delaying; the other two groups worked discontinuous systems that were either advancing or delaying. RESULTS—Few effects were found of direction of rotation on chronic measures of health and wellbeing, even when the systems incorporated "quick returns" (a break of only 8 hours when changing from one shift to another). This was despite the use of measures previously shown to be sensitive to the effects of a broad range of features of shift systems. However, advancing continuous systems seemed to be associated with marginally steeper declines in alertness across the shift (F (3,1080)=2.87, p<0.05). They were also associated with shorter sleeps between morning shifts (F (1,404)=4.01, p<0.05), but longer sleeps between afternoons (F (1,424)=4.16, p<0.05). CONCLUSIONS—The absence of negative effects of advancing shifts upon the chronic outcome measures accorded with previous evidence that advancing shifts may not be as harmful as early research indicated. However, this interpretation is tempered by the possibility that difficult shift systems self select those workers most able to cope with their deleterious effects. The presence of quick returns in advancing continuous systems seemed to impact upon some of the acute measures such as duration of sleep, although the associated effects on alertness seemed to be marginal. Keywords: shift rotation; health; alertness PMID:10984340
System Dynamic Analysis of a Wind Tunnel Model with Applications to Improve Aerodynamic Data Quality
NASA Technical Reports Server (NTRS)
Buehrle, Ralph David
1997-01-01
The research investigates the effect of wind tunnel model system dynamics on measured aerodynamic data. During wind tunnel tests designed to obtain lift and drag data, the required aerodynamic measurements are the steady-state balance forces and moments, pressures, and model attitude. However, the wind tunnel model system can be subjected to unsteady aerodynamic and inertial loads which result in oscillatory translations and angular rotations. The steady-state force balance and inertial model attitude measurements are obtained by filtering and averaging data taken during conditions of high model vibrations. The main goals of this research are to characterize the effects of model system dynamics on the measured steady-state aerodynamic data and develop a correction technique to compensate for dynamically induced errors. Equations of motion are formulated for the dynamic response of the model system subjected to arbitrary aerodynamic and inertial inputs. The resulting modal model is examined to study the effects of the model system dynamic response on the aerodynamic data. In particular, the equations of motion are used to describe the effect of dynamics on the inertial model attitude, or angle of attack, measurement system that is used routinely at the NASA Langley Research Center and other wind tunnel facilities throughout the world. This activity was prompted by the inertial model attitude sensor response observed during high levels of model vibration while testing in the National Transonic Facility at the NASA Langley Research Center. The inertial attitude sensor cannot distinguish between the gravitational acceleration and centrifugal accelerations associated with wind tunnel model system vibration, which results in a model attitude measurement bias error. Bias errors over an order of magnitude greater than the required device accuracy were found in the inertial model attitude measurements during dynamic testing of two model systems. Based on a theoretical modal approach, a method using measured vibration amplitudes and measured or calculated modal characteristics of the model system is developed to correct for dynamic bias errors in the model attitude measurements. The correction method is verified through dynamic response tests on two model systems and actual wind tunnel test data.
Detailed Uncertainty Analysis of the ZEM-3 Measurement System
NASA Technical Reports Server (NTRS)
Mackey, Jon; Sehirlioglu, Alp; Dynys, Fred
2014-01-01
The measurement of Seebeck coefficient and electrical resistivity are critical to the investigation of all thermoelectric systems. Therefore, it stands that the measurement uncertainty must be well understood to report ZT values which are accurate and trustworthy. A detailed uncertainty analysis of the ZEM-3 measurement system has been performed. The uncertainty analysis calculates error in the electrical resistivity measurement as a result of sample geometry tolerance, probe geometry tolerance, statistical error, and multi-meter uncertainty. The uncertainty on Seebeck coefficient includes probe wire correction factors, statistical error, multi-meter uncertainty, and most importantly the cold-finger effect. The cold-finger effect plagues all potentiometric (four-probe) Seebeck measurement systems, as heat parasitically transfers through thermocouple probes. The effect leads to an asymmetric over-estimation of the Seebeck coefficient. A thermal finite element analysis allows for quantification of the phenomenon, and provides an estimate on the uncertainty of the Seebeck coefficient. The thermoelectric power factor has been found to have an uncertainty of +9-14 at high temperature and 9 near room temperature.
The non-contact biometric identified bio signal measurement sensor and algorithms.
Kim, Chan-Il; Lee, Jong-Ha
2018-01-01
In these days, wearable devices have been developed for effectively measuring biological data. However, these devices have tissue allege and noise problem. To solve these problems, biometric measurement based on a non-contact method, such as face image sequencing is developed. This makes it possible to measure biometric data without any operation and side effects. However, it is impossible for a remote center to identify the person whose data are measured by the novel methods. In this paper, we propose the novel non-contact heart rate and blood pressure imaging system, Deep Health Eye. This system has authentication process at the same time as measuring bio signals, through non-contact method. In the future, this system can be convenient home bio signal monitoring system by combined with smart mirror.
NASA Technical Reports Server (NTRS)
Watson, Michael D.; Kelley, Gary W.
2012-01-01
The Department of Defense (DoD) defined System Operational Effectiveness (SOE) model provides an exceptional framework for an affordable approach to the development and operation of space launch vehicles and their supporting infrastructure. The SOE model provides a focal point from which to direct and measure technical effectiveness and process efficiencies of space launch vehicles. The application of the SOE model to a space launch vehicle's development and operation effort leads to very specific approaches and measures that require consideration during the design phase. This paper provides a mapping of the SOE model to the development of space launch vehicles for human exploration by addressing the SOE model key points of measurement including System Performance, System Availability, Technical Effectiveness, Process Efficiency, System Effectiveness, Life Cycle Cost, and Affordable Operational Effectiveness. In addition, the application of the SOE model to the launch vehicle development process is defined providing the unique aspects of space launch vehicle production and operations in lieu of the traditional broader SOE context that examines large quantities of fielded systems. The tailoring and application of the SOE model to space launch vehicles provides some key insights into the operational design drivers, capability phasing, and operational support systems.
System Identification for the Clipper Liberty C96 Wind Turbine
NASA Astrophysics Data System (ADS)
Showers, Daniel
System identification techniques are powerful tools that help improve modeling capabilities of real world dynamic systems. These techniques are well established and have been successfully used on countless systems in many areas. However, wind turbines provide a unique challenge for system identification because of the difficulty in measuring its primary input: wind. This thesis first motivates the problem by demonstrating the challenges with wind turbine system identification using both simulations and real data. It then suggests techniques toward successfully identifying a dynamic wind turbine model including the notion of an effective wind speed and how it might be measured. Various levels of simulation complexity are explored for insights into calculating an effective wind speed. In addition, measurements taken from the University of Minnesota's Clipper Liberty C96 research wind turbine are used for a preliminary investigation into the effective wind speed calculation and system identification of a real world wind turbine.
Laserna, J J; Reyes, R Fernández; González, R; Tobaria, L; Lucena, P
2009-06-08
We report on an experimental study of the effect of atmospheric turbulence on laser induced breakdown spectroscopy (LIBS) measurements. The characteristics of the atmosphere dictate specific performance constraints to this technology. Unlike classical laboratory LIBS systems where the distance to the sample is well known and characterized, LIBS systems working at several tens of meters to the target have specific atmospheric propagation conditions that cause the quality of the LIBS signals to be affected to a significant extent. Using a new LIBS based sensor system fitted with a nanosecond laser emitting at 1064 nm, propagation effects at distances of up to 120 m were investigated. The effects observed include wander and scintillation in the outgoing laser beam and in the return atomic emission signal. Plasmas were formed on aluminium targets. Average signal levels and signal fluctuations are measured so the effect of atmospheric turbulence on LIBS measurements is quantified.
[A Digital System for Bioimpedance and Electrical Impedance Tomography Measurement System].
Chen, Xiaoyan; Gao, Nana; Huang, Huafang
2015-06-01
A digital system for bioimpedance and electrical impedance tomography (EIT) measurement controlled by an ATmega16 microcontroller was constructed in our laboratory. There are eight digital electrodes using AD5933 to measure the impedance of the targets, and the data is transmitted to the computer wirelessly through nRF24L01. The structure of the system, circuit design, system testing, vitro measurements of animals' tissues and electrical impedance tomography are introduced specifically in this paper. The experimental results showed that the system relative error was 0.42%, and the signal noise ratio was 76.3 dB. The system not only can be used to measure the impedance by any two electrodes within the frequency of 1-100 kHz in a sweep scanning, but also can reconstruct the images of EIT. The animal experiments showed that the data was valid and plots were fitting with Cole-Cole theory. The testing verified the feasibility and effectiveness of the system. The images reconstructed of a salt-water tank are satisfactory and match with the actual distribution of the tank. The system improves the effectiveness of the front-end measuring signal and the stability of the system greatly.
Mukherjee, Ramtanu; Ghosh, Sanchita; Gupta, Bharat; Chakravarty, Tapas
2018-01-22
The effectiveness of any remote healthcare monitoring system depends on how much accurate, patient-friendly, versatile, and cost-effective measurement it is delivering. There has always been a huge demand for such a long-term noninvasive remote blood pressure (BP) measurement system, which could be used worldwide in the remote healthcare industry. Thus, noninvasive continuous BP measurement and remote monitoring have become an emerging area in the remote healthcare industry. Photoplethysmography-based (PPG) BP measurement is a continuous, unobtrusive, patient-friendly, and cost-effective solution. However, BP measurements through PPG sensors are not much reliable and accurate due to some major limitations like pressure disturbance, motion artifacts, and variations in human skin tone. A novel reflective PPG sensor has been developed to eliminate the abovementioned pressure disturbance and motion artifacts during the BP measurement. Considering the variations of the human skin tone across demography, a novel algorithm has been developed to make the BP measurement accurate and reliable. The training dataset captured 186 subjects' data and the trial dataset captured another new 102 subjects' data. The overall accuracy achieved by using the proposed method is nearly 98%. Thus, demonstrating the efficacy of the proposed method. The developed BP monitoring system is quite accurate, reliable, cost-effective, handy, and user friendly. It is also expected that this system would be quite useful to monitor the BP of infants, elderly people, patients having wounds, burn injury, or in the intensive care unit environment.
Stochastic sensitivity measure for mistuned high-performance turbines
NASA Technical Reports Server (NTRS)
Murthy, Durbha V.; Pierre, Christophe
1992-01-01
A stochastic measure of sensitivity is developed in order to predict the effects of small random blade mistuning on the dynamic aeroelastic response of turbomachinery blade assemblies. This sensitivity measure is based solely on the nominal system design (i.e., on tuned system information), which makes it extremely easy and inexpensive to calculate. The measure has the potential to become a valuable design tool that will enable designers to evaluate mistuning effects at a preliminary design stage and thus assess the need for a full mistuned rotor analysis. The predictive capability of the sensitivity measure is illustrated by examining the effects of mistuning on the aeroelastic modes of the first stage of the oxidizer turbopump in the Space Shuttle Main Engine. Results from a full analysis mistuned systems confirm that the simple stochastic sensitivity measure predicts consistently the drastic changes due to misturning and the localization of aeroelastic vibration to a few blades.
Cost-effectiveness methodology for computer systems selection
NASA Technical Reports Server (NTRS)
Vallone, A.; Bajaj, K. S.
1980-01-01
A new approach to the problem of selecting a computer system design has been developed. The purpose of this methodology is to identify a system design that is capable of fulfilling system objectives in the most economical way. The methodology characterizes each system design by the cost of the system life cycle and by the system's effectiveness in reaching objectives. Cost is measured by a 'system cost index' derived from an analysis of all expenditures and possible revenues over the system life cycle. Effectiveness is measured by a 'system utility index' obtained by combining the impact that each selection factor has on the system objectives and it is assessed through a 'utility curve'. A preestablished algorithm combines cost and utility and provides a ranking of the alternative system designs from which the 'best' design is selected.
A high-precision velocity measuring system design for projectiles based on S-shaped laser screen
NASA Astrophysics Data System (ADS)
Liu, Huayi; Qian, Zheng; Yu, Hao; Li, Yutao
2018-03-01
The high-precision measurement of the velocity of high-speed flying projectile is of great significance for the evaluation and development of modern weapons. The velocity of the high-speed flying projectile is usually measured by laser screen velocity measuring system. But this method cannot achieve the repeated measurements, so we cannot make an indepth evaluation of the uncertainty about the measuring system. This paper presents a design based on S-shaped laser screen velocity measuring system. This design can achieve repeated measurements. Therefore, it can effectively reduce the uncertainty of the velocity measuring system. In addition, we made a detailed analysis of the uncertainty of the measuring system. The measurement uncertainty is 0.2% when the velocity of the projectile is about 200m/s.
A new method for distortion magnetic field compensation of a geomagnetic vector measurement system
NASA Astrophysics Data System (ADS)
Liu, Zhongyan; Pan, Mengchun; Tang, Ying; Zhang, Qi; Geng, Yunling; Wan, Chengbiao; Chen, Dixiang; Tian, Wugang
2016-12-01
The geomagnetic vector measurement system mainly consists of three-axis magnetometer and an INS (inertial navigation system), which have many ferromagnetic parts on them. The magnetometer is always distorted by ferromagnetic parts and other electric equipments such as INS and power circuit module within the system, which can lead to geomagnetic vector measurement error of thousands of nT. Thus, the geomagnetic vector measurement system has to be compensated in order to guarantee the measurement accuracy. In this paper, a new distortion magnetic field compensation method is proposed, in which a permanent magnet with different relative positions is used to change the ambient magnetic field to construct equations of the error model parameters, and the parameters can be accurately estimated by solving linear equations. In order to verify effectiveness of the proposed method, the experiment is conducted, and the results demonstrate that, after compensation, the components errors of measured geomagnetic field are reduced significantly. It demonstrates that the proposed method can effectively improve the accuracy of the geomagnetic vector measurement system.
Impact of science objectives and requirements on probe mission and system design
NASA Technical Reports Server (NTRS)
Ledbetter, K. W.
1974-01-01
Problem areas in probe science technology are discussed that require a solution before probe systems can actually be designed. Considered are the effects of the model atmospheres on probe design; secondly, the effects of implementing the requirements to locate and measure the clouds and, trade-offs between descent sampling and measurement criteria as they affect probe system design.
NASA Technical Reports Server (NTRS)
Mulhall, B. D. L.
1980-01-01
The development of both quantitative criteria that were used to evaluate conceptional systems for automating the functions for the FBI Identification Division is described. Specific alternative systems for automation were compared by using these developed criteria, defined as Measures of Effectiveness (MOE), to gauge system's performance in attempting to achieve certain goals. The MOE, essentially measurement tools that were developed through the combination of suitable parameters, pertain to each conceivable area of system operation. The methods and approaches used, both in selecting the parameters and in using the resulting MOE, are described.
Assessing health system performance in developing countries: a review of the literature.
Kruk, Margaret Elizabeth; Freedman, Lynn P
2008-03-01
With the setting of ambitious international health goals and an influx of additional development assistance for health, there is growing interest in assessing the performance of health systems in developing countries. This paper proposes a framework for the assessment of health system performance and reviews the literature on indicators currently in use to measure performance using online medical and public health databases. This was complemented by a review of relevant books and reports in the grey literature. The indicators were organized into three categories: effectiveness, equity, and efficiency. Measures of health system effectiveness were improvement in health status, access to and quality of care and, increasingly, patient satisfaction. Measures of equity included access and quality of care for disadvantaged groups together with fair financing, risk protection and accountability. Measures of efficiency were appropriate levels of funding, the cost-effectiveness of interventions, and effective administration. This framework and review of indicators may be helpful to health policy makers interested in assessing the effects of different policies, expenditures, and organizational structures on health outputs and outcomes in developing countries.
Exercise Performance Measurement with Smartphone Embedded Sensor for Well-Being Management
Liu, Chung-Tse; Chan, Chia-Tai
2016-01-01
Regular physical activity reduces the risk of many diseases and improves physical and mental health. However, physical inactivity is widespread globally. Improving physical activity levels is a global concern in well-being management. Exercise performance measurement systems have the potential to improve physical activity by providing feedback and motivation to users. We propose an exercise performance measurement system for well-being management that is based on the accumulated activity effective index (AAEI) and incorporates a smartphone-embedded sensor. The proposed system generates a numeric index that is based on users’ exercise performance: their level of physical activity and number of days spent exercising. The AAEI presents a clear number that can serve as a useful feedback and goal-setting tool. We implemented the exercise performance measurement system by using a smartphone and conducted experiments to assess the feasibility of the system and investigated the user experience. We recruited 17 participants for validating the feasibility of the measurement system and a total of 35 participants for investigating the user experience. The exercise performance measurement system showed an overall precision of 88% in activity level estimation. Users provided positive feedback about their experience with the exercise performance measurement system. The proposed system is feasible and has a positive effective on well-being management. PMID:27727188
Exercise Performance Measurement with Smartphone Embedded Sensor for Well-Being Management.
Liu, Chung-Tse; Chan, Chia-Tai
2016-10-11
Regular physical activity reduces the risk of many diseases and improves physical and mental health. However, physical inactivity is widespread globally. Improving physical activity levels is a global concern in well-being management. Exercise performance measurement systems have the potential to improve physical activity by providing feedback and motivation to users. We propose an exercise performance measurement system for well-being management that is based on the accumulated activity effective index (AAEI) and incorporates a smartphone-embedded sensor. The proposed system generates a numeric index that is based on users' exercise performance: their level of physical activity and number of days spent exercising. The AAEI presents a clear number that can serve as a useful feedback and goal-setting tool. We implemented the exercise performance measurement system by using a smartphone and conducted experiments to assess the feasibility of the system and investigated the user experience. We recruited 17 participants for validating the feasibility of the measurement system and a total of 35 participants for investigating the user experience. The exercise performance measurement system showed an overall precision of 88% in activity level estimation. Users provided positive feedback about their experience with the exercise performance measurement system. The proposed system is feasible and has a positive effective on well-being management.
Systems Measures of Water Distribution System Resilience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klise, Katherine A.; Murray, Regan; Walker, La Tonya Nicole
2015-01-01
Resilience is a concept that is being used increasingly to refer to the capacity of infrastructure systems to be prepared for and able to respond effectively and rapidly to hazardous events. In Section 2 of this report, drinking water hazards, resilience literature, and available resilience tools are presented. Broader definitions, attributes and methods for measuring resilience are presented in Section 3. In Section 4, quantitative systems performance measures for water distribution systems are presented. Finally, in Section 5, the performance measures and their relevance to measuring the resilience of water systems to hazards is discussed along with needed improvements tomore » water distribution system modeling tools.« less
Measuring effectiveness of a university by a parallel network DEA model
NASA Astrophysics Data System (ADS)
Kashim, Rosmaini; Kasim, Maznah Mat; Rahman, Rosshairy Abd
2017-11-01
Universities contribute significantly to the development of human capital and socio-economic improvement of a country. Due to that, Malaysian universities carried out various initiatives to improve their performance. Most studies have used the Data Envelopment Analysis (DEA) model to measure efficiency rather than effectiveness, even though, the measurement of effectiveness is important to realize how effective a university in achieving its ultimate goals. A university system has two major functions, namely teaching and research and every function has different resources based on its emphasis. Therefore, a university is actually structured as a parallel production system with its overall effectiveness is the aggregated effectiveness of teaching and research. Hence, this paper is proposing a parallel network DEA model to measure the effectiveness of a university. This model includes internal operations of both teaching and research functions into account in computing the effectiveness of a university system. In literature, the graduate and the number of program offered are defined as the outputs, then, the employed graduates and the numbers of programs accredited from professional bodies are considered as the outcomes for measuring the teaching effectiveness. Amount of grants is regarded as the output of research, while the different quality of publications considered as the outcomes of research. A system is considered effective if only all functions are effective. This model has been tested using a hypothetical set of data consisting of 14 faculties at a public university in Malaysia. The results show that none of the faculties is relatively effective for the overall performance. Three faculties are effective in teaching and two faculties are effective in research. The potential applications of the parallel network DEA model allow the top management of a university to identify weaknesses in any functions in their universities and take rational steps for improvement.
10 CFR 436.18 - Measuring cost-effectiveness.
Code of Federal Regulations, 2012 CFR
2012-01-01
... water system, considered in determining such matters as the optimal size of a solar energy system, the... 10 Energy 3 2012-01-01 2012-01-01 false Measuring cost-effectiveness. 436.18 Section 436.18 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...
10 CFR 436.18 - Measuring cost-effectiveness.
Code of Federal Regulations, 2014 CFR
2014-01-01
... water system, considered in determining such matters as the optimal size of a solar energy system, the... 10 Energy 3 2014-01-01 2014-01-01 false Measuring cost-effectiveness. 436.18 Section 436.18 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...
10 CFR 436.18 - Measuring cost-effectiveness.
Code of Federal Regulations, 2013 CFR
2013-01-01
... water system, considered in determining such matters as the optimal size of a solar energy system, the... 10 Energy 3 2013-01-01 2013-01-01 false Measuring cost-effectiveness. 436.18 Section 436.18 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...
Engineering performance metrics
NASA Astrophysics Data System (ADS)
Delozier, R.; Snyder, N.
1993-03-01
Implementation of a Total Quality Management (TQM) approach to engineering work required the development of a system of metrics which would serve as a meaningful management tool for evaluating effectiveness in accomplishing project objectives and in achieving improved customer satisfaction. A team effort was chartered with the goal of developing a system of engineering performance metrics which would measure customer satisfaction, quality, cost effectiveness, and timeliness. The approach to developing this system involved normal systems design phases including, conceptual design, detailed design, implementation, and integration. The lessons teamed from this effort will be explored in this paper. These lessons learned may provide a starting point for other large engineering organizations seeking to institute a performance measurement system accomplishing project objectives and in achieving improved customer satisfaction. To facilitate this effort, a team was chartered to assist in the development of the metrics system. This team, consisting of customers and Engineering staff members, was utilized to ensure that the needs and views of the customers were considered in the development of performance measurements. The development of a system of metrics is no different than the development of any type of system. It includes the steps of defining performance measurement requirements, measurement process conceptual design, performance measurement and reporting system detailed design, and system implementation and integration.
Schawo, S; Bouwmans, C; van der Schee, E; Hendriks, V; Brouwer, W; Hakkaart, L
2017-09-19
Systemic family interventions have shown to be effective in adolescents with substance use disorder and delinquent behavior. The interventions target interactions between the adolescent and involved systems (i.e. youth, family, peers, neighbors, school, work, and society). Next to effectiveness considerations, economic aspects have gained attention. However, conventional generic quality of life measures used in health economic evaluations may not be able to capture the broad effects of systemic interventions. This study aims to identify existing outcome measures, which capture the broad effects of systemic family interventions, and allow use in a health economic framework. We based our systematic review on clinical studies in the field. Our goal was to identify effectiveness studies of psychosocial interventions for adolescents with substance use disorder and delinquent behavior and to distill the instruments used in these studies to measure effects. Searched databases were PubMed, Education Resource Information Center (ERIC), Cochrane and Psychnet (PsycBOOKSc, PsycCRITIQUES, print). Identified instruments were ranked according to the number of systems covered (comprehensiveness). In addition, their use for health economic analyses was evaluated according to suitability characteristics such as brevity, accessibility, psychometric properties, etc. One thousand three hundred seventy-eight articles were found and screened for eligibility. Eighty articles were selected, 8 instruments were identified covering 5 or more systems. The systematic review identified instruments from the clinical field suitable to evaluate systemic family interventions in a health economic framework. None of them had preference-weights available. Hence, a next step could be to attach preference-weights to one of the identified instruments to allow health economic evaluations of systemic family interventions.
Lightning Current Measurement with Fiber-Optic Sensor
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.; Mata, Carlos T.; Mata, Angel G.; Snyder, Gary P.
2014-01-01
A fiber-optic current sensor is successfully developed with many potential applications for electric current measurement. Originally developed for in-flight lightning measurement, the sensor utilizes Faraday Effect in an optical fiber. The Faraday Effect causes linear light polarization in a fiber to rotate when the fiber is exposed to a magnetic field. The polarization change is detected using a reflective polarimetric scheme. Forming fiber loops and applying Ampere's law, measuring the total light rotation results in the determination of the total current enclosed. The sensor is conformable to complex structure geometry. It is also non-conductive and immune to electromagnetic interference, saturation or hysteresis. Installation is non-intrusive, and the sensor can be safely routed through flammable areas. Two similar sensor systems are described in this paper. The first system operates at 1310nm laser wavelength and is capable of measuring approximately 300 A - 300 kA, a 60 dB range. Laboratory validation results of aircraft lighting direct and in-direct effect current amplitudes are reported for this sensor. The second system operates at 1550nm wavelength and can measure about 400 A - 400 kA. Triggered-lightning measurement data are presented for this system. Good results are achieved in all cases.
Evaluating the effect of online data compression on the disk cache of a mass storage system
NASA Technical Reports Server (NTRS)
Pentakalos, Odysseas I.; Yesha, Yelena
1994-01-01
A trace driven simulation of the disk cache of a mass storage system was used to evaluate the effect of an online compression algorithm on various performance measures. Traces from the system at NASA's Center for Computational Sciences were used to run the simulation and disk cache hit ratios, number of files and bytes migrating to tertiary storage were measured. The measurements were performed for both an LRU and a size based migration algorithm. In addition to seeing the effect of online data compression on the disk cache performance measure, the simulation provided insight into the characteristics of the interactive references, suggesting that hint based prefetching algorithms are the only alternative for any future improvements to the disk cache hit ratio.
NASA Astrophysics Data System (ADS)
Lee, J.-W.; Jeong, J.-R.; Kim, D.-H.; Ahn, J. S.; Kim, J.; Shin, S.-C.
2000-10-01
We have constructed a three-configurational surface magneto-optical Kerr effect system, which provides the simultaneous measurements of the "polar," "longitudinal," and "transverse" Kerr hysteresis loops at the position where deposition is carried out in an ultrahigh vacuum growth chamber. The present system enables in situ three-dimensional vectorial studies of ultrathin film magnetism with a submonolayer sensitivity. We present three-configurational hysteresis loops measured during the growth of Co films on Pd(111), glass, and Pd/glass substrates.
Interactions measurement payload for Shuttle
NASA Technical Reports Server (NTRS)
Guidice, D. A.; Pike, C. P.
1985-01-01
The Interactions Measurement Payload for Shuttle (IMPS) consisted of engineering experiments to determine the effects of the space environment on projected Air Force space systems. Measurements by IMPS on a polar-orbit Shuttle flight will lead to detailed knowledge of the interaction of the low-altitude polar-auroral environment on materials, equipment and technologies to be used in future large, high-power space systems. The results from the IMPS measurements will provide direct input to MIL-STD design guidelines and test standards that properly account for space-environment effects.
Frehmann, T; Nafo, I; Niemann, A; Geiger, W F
2002-01-01
For the examination of the effects of different storm water management strategies in an urban catchment area on receiving water quality, an integrated simulation of the sewer system, wastewater treatment plant and receiving water is carried out. In the sewer system real-time control measures are implemented. As examples of source control measures the reduction of wastewater and the reduction of the amount of impervious surfaces producing storm water discharges are examined. The surface runoff calculation and the simulation of the sewer system and the WWTP are based on a MATLAB/SIMULINK simulation environment. The impact of the measures on the receiving water is simulated using AQUASIM. It can be shown that the examined storm water management measures, especially the source control measures, can reduce the combined sewer overflow volume and the pollutant discharge load considerably. All examined measures also have positive effects on the receiving water quality. Moreover, the reduction of impervious surfaces avoids combined sewer overflow activities, and in consequence prevents pollutants from discharging into the receiving water after small rainfall events. However, the receiving water quality improvement may not be seen as important enough to avoid acute receiving water effects in general.
The Stability of Observational and Student Survey Measures of Teaching Effectiveness
ERIC Educational Resources Information Center
Polikoff, Morgan S.
2015-01-01
Responding to federal policy and recent research, states and districts have developed and begun implementing multiple-measure teacher evaluation systems. These systems generally include observational and/or student survey measures of instructional quality alongside measures of teachers' contributions to student learning (e.g., value-added models…
Measurement of Entropy of a Multiparticle System: a ``Do-List''
NASA Astrophysics Data System (ADS)
Bialas, A.; Czyz, W.
2000-03-01
An algorithm for measurement of entropy in multiparticle systems, based on the recently published proposal of the present authors is given. Dependence on discretization of the system and effects of multiparticle correlations are discussed in some detail.
NASA Astrophysics Data System (ADS)
Wu, Long; Chen, Lei; Wang, Hao; Liu, Xiaoyu; Wang, Zhen
2017-04-01
As many emergent phenomena of superconductivity appear on a smaller scale and at lower dimension, commercial magnetic property measurement systems (MPMSs) no longer provide the sensitivity necessary to study the Meissner effect of small superconductors. The nano-scale superconducting quantum interference device (nano-SQUID) is considered one of the most sensitive magnetic sensors for the magnetic characterization of mesoscopic or microscopic samples. Here, we develop a customized on-chip nano-SQUID measurement system based on a pulsed current biasing method. The noise performance of our system is approximately 4.6 × 10-17 emu/Hz1/2, representing an improvement of 9 orders of magnitude compared with that of a commercial MPMS (~10-8 emu/Hz1/2). Furthermore, we demonstrate the measurement of the Meissner effect of a single indium (In) particle (of 47 μm in diameter) using our on-chip nano-SQUID system. The system enables the observation of the prompt superconducting transition of the Meissner effect of a single In particle, thereby providing more accurate characterization of the critical field Hc and temperature Tc. In addition, the retrapping field Hre as a function of temperature T of single In particle shows disparate behavior from that of a large ensemble.
Moorthy, Arun S; Eberl, Hermann J
2014-04-01
Fermentation reactor systems are a key platform in studying intestinal microflora, specifically with respect to questions surrounding the effects of diet. In this study, we develop computational representations of colon fermentation reactor systems as a way to assess the influence of three design elements (number of reactors, emptying mechanism, and inclusion of microbial immobilization) on three performance measures (total biomass density, biomass composition, and fibre digestion efficiency) using a fractional-factorial experimental design. It was determined that the choice of emptying mechanism showed no effect on any of the performance measures. Additionally, it was determined that none of the design criteria had any measurable effect on reactor performance with respect to biomass composition. It is recommended that model fermentation systems used in the experimenting of dietary effects on intestinal biomass composition be streamlined to only include necessary system design complexities, as the measured performance is not benefited by the addition of microbial immobilization mechanisms or semi-continuous emptying scheme. Additionally, the added complexities significantly increase computational time during simulation experiments. It was also noted that the same factorial experiment could be directly adapted using in vitro colon fermentation systems. Copyright © 2013 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Doskey, Steven Craig
2014-01-01
This research presents an innovative means of gauging Systems Engineering effectiveness through a Systems Engineering Relative Effectiveness Index (SE REI) model. The SE REI model uses a Bayesian Belief Network to map causal relationships in government acquisitions of Complex Information Systems (CIS), enabling practitioners to identify and…
NASA Astrophysics Data System (ADS)
Liang, Li; Takaaki, Ohkubo; Guang-hui, Li
2018-03-01
In recent years, earthquakes have occurred frequently, and the seismic performance of existing school buildings has become particularly important. The main method for improving the seismic resistance of existing buildings is reinforcement. However, there are few effective methods to evaluate the effect of reinforcement. Ambient vibration measurement experiments were conducted before and after seismic retrofitting using wireless measurement system and the changes of vibration characteristics were compared. The changes of acceleration response spectrum, natural periods and vibration modes indicate that the wireless vibration measurement system can be effectively applied to evaluate the effect of seismic retrofitting. The method can evaluate the effect of seismic retrofitting qualitatively, it is difficult to evaluate the effect of seismic retrofitting quantitatively at this stage.
Cost-effectiveness analysis of risk-reduction measures to reach water safety targets.
Lindhe, Andreas; Rosén, Lars; Norberg, Tommy; Bergstedt, Olof; Pettersson, Thomas J R
2011-01-01
Identifying the most suitable risk-reduction measures in drinking water systems requires a thorough analysis of possible alternatives. In addition to the effects on the risk level, also the economic aspects of the risk-reduction alternatives are commonly considered important. Drinking water supplies are complex systems and to avoid sub-optimisation of risk-reduction measures, the entire system from source to tap needs to be considered. There is a lack of methods for quantification of water supply risk reduction in an economic context for entire drinking water systems. The aim of this paper is to present a novel approach for risk assessment in combination with economic analysis to evaluate risk-reduction measures based on a source-to-tap approach. The approach combines a probabilistic and dynamic fault tree method with cost-effectiveness analysis (CEA). The developed approach comprises the following main parts: (1) quantification of risk reduction of alternatives using a probabilistic fault tree model of the entire system; (2) combination of the modelling results with CEA; and (3) evaluation of the alternatives with respect to the risk reduction, the probability of not reaching water safety targets and the cost-effectiveness. The fault tree method and CEA enable comparison of risk-reduction measures in the same quantitative unit and consider costs and uncertainties. The approach provides a structured and thorough analysis of risk-reduction measures that facilitates transparency and long-term planning of drinking water systems in order to avoid sub-optimisation of available resources for risk reduction. Copyright © 2010 Elsevier Ltd. All rights reserved.
Influence of video compression on the measurement error of the television system
NASA Astrophysics Data System (ADS)
Sotnik, A. V.; Yarishev, S. N.; Korotaev, V. V.
2015-05-01
Video data require a very large memory capacity. Optimal ratio quality / volume video encoding method is one of the most actual problem due to the urgent need to transfer large amounts of video over various networks. The technology of digital TV signal compression reduces the amount of data used for video stream representation. Video compression allows effective reduce the stream required for transmission and storage. It is important to take into account the uncertainties caused by compression of the video signal in the case of television measuring systems using. There are a lot digital compression methods. The aim of proposed work is research of video compression influence on the measurement error in television systems. Measurement error of the object parameter is the main characteristic of television measuring systems. Accuracy characterizes the difference between the measured value abd the actual parameter value. Errors caused by the optical system can be selected as a source of error in the television systems measurements. Method of the received video signal processing is also a source of error. Presence of error leads to large distortions in case of compression with constant data stream rate. Presence of errors increases the amount of data required to transmit or record an image frame in case of constant quality. The purpose of the intra-coding is reducing of the spatial redundancy within a frame (or field) of television image. This redundancy caused by the strong correlation between the elements of the image. It is possible to convert an array of image samples into a matrix of coefficients that are not correlated with each other, if one can find corresponding orthogonal transformation. It is possible to apply entropy coding to these uncorrelated coefficients and achieve a reduction in the digital stream. One can select such transformation that most of the matrix coefficients will be almost zero for typical images . Excluding these zero coefficients also possible reducing of the digital stream. Discrete cosine transformation is most widely used among possible orthogonal transformation. Errors of television measuring systems and data compression protocols analyzed In this paper. The main characteristics of measuring systems and detected sources of their error detected. The most effective methods of video compression are determined. The influence of video compression error on television measuring systems was researched. Obtained results will increase the accuracy of the measuring systems. In television image quality measuring system reduces distortion identical distortion in analog systems and specific distortions resulting from the process of coding / decoding digital video signal and errors in the transmission channel. By the distortions associated with encoding / decoding signal include quantization noise, reducing resolution, mosaic effect, "mosquito" effect edging on sharp drops brightness, blur colors, false patterns, the effect of "dirty window" and other defects. The size of video compression algorithms used in television measuring systems based on the image encoding with intra- and inter prediction individual fragments. The process of encoding / decoding image is non-linear in space and in time, because the quality of the playback of a movie at the reception depends on the pre- and post-history of a random, from the preceding and succeeding tracks, which can lead to distortion of the inadequacy of the sub-picture and a corresponding measuring signal.
Evaluation of effectiveness of combined sewer overflow control measures by operational data.
Schroeder, K; Riechel, M; Matzinger, A; Rouault, P; Sonnenberg, H; Pawlowsky-Reusing, E; Gnirss, R
2011-01-01
The effect of combined sewer overflow (CSO) control measures should be validated during operation based on monitoring of CSO activity and subsequent comparison with (legal) requirements. However, most CSO monitoring programs have been started only recently and therefore no long-term data is available for reliable efficiency control. A method is proposed that focuses on rainfall data for evaluating the effectiveness of CSO control measures. It is applicable if a sufficient time-series of rainfall data and a limited set of data on CSO discharges are available. The method is demonstrated for four catchments of the Berlin combined sewer system. The analysis of the 2000-2007 data shows the effect of CSO control measures, such as activation of in-pipe storage capacities within the Berlin system. The catchment, where measures are fully implemented shows less than 40% of the CSO activity of those catchments, where measures have not yet or not yet completely been realised.
NASA Astrophysics Data System (ADS)
Smyth, Cathal
This thesis is a compilation of studies on delocalization measures, entanglement, and the role of quantum coherence in electronic energy transfer (EET) in light-harvesting complexes. The first two chapters after the introduction provide foundational knowledge of quantum information and light-harvesting, respectively. Chapter 2 introduces concepts from quantum information such as purity, bipartite entanglement and criteria for its measurement. The peripheral light-harvesting complex LH2, isolated from the anoxygenic purple bacterium Rhodopseudomonas acidophila, is employed as model system of interest. This light-harvesting complex, along with a description of the process of light-harvesting, the presence of quantum coherence, and the different models used to simulate EET, are described in chapter 3. In combination these two chapters lay the foundation for chapter 4, a critical assessment of the current measures of delocalization employed in EET studies, their relationship, and overall effectiveness. The conclusion is that entanglement based measures are most effective at measuring quantum effects, and that they can be related to more conventional delocalization measures such as the inverse participation ratio (IPR) by taking into account the entropy of the system under study. All the measures within this chapter are known as bipartite measures, and only measure the strength of correlation between two sites. The fifth chapter presents the core of this thesis. Following a brief introduction to the concept of multipartite entanglement, the development of multipartite delocalization measures that give high-resolution information on quantum coherence in light-harvesting complexes is detailed. In contrast to other measures, these analytical measures can detect many body correlations in large systems undergoing decoherence. We determine that, much like the bipartite entanglement based measures of chapter 4, these measures are also a function of system entropy, and have a similar hierarchial structure as that of multipartite entanglement measures. The final chapter applies these measures to our model LH2 complex, and draws conclusions on the role of bipartite delocalization and multipartite delocalization in EET.
[An integrated system of blood pressure measurement with bluetooth communication].
Wang, Wei; Wang, Jing; Sun, Hongyang; Xu, Zuyang; Chai, Xinyu
2012-07-01
The development of the integrated blood pressure system with bluetooth communication function is introduced. Experimental results show that the system can complete blood pressure measurement and data transmission wireless effectively, which can be used in m-Health in future.
Preparation and measurement of FBG-based length, temperature, and vibration sensors
NASA Astrophysics Data System (ADS)
Mikel, Bretislav; Helan, Radek; Buchta, Zdenek; Jelinek, Michal; Cip, Ondrej
2016-12-01
We present system of structure health measurement by optical fiber sensors based on fiber Bragg gratings. Our system is focused to additionally install to existing buildings. We prepared first set-up of the system to monitoring of the nuclear power plant containment shape deformation. The presented system can measure up to several tens of sensors simultaneously. Each sensor contains optical fiber grating to measurement of change of length and the other independed fiber grating to monitor the temperature and the other ineligible effects.
Continuous 30-day measurements utilizing the monkey metabolism pod. [study of weightlessness effects
NASA Technical Reports Server (NTRS)
Pace, N.; Kodama, A. M.; Mains, R. C.; Rahlmann, D. F.; Grunbaum, B. W.
1977-01-01
A fiberglass system was previously described, using which quantitative physiological measurements could be made to study the effects of weightlessness on 10 to 14 kg adult monkeys maintained in comfortable restraint under space flight conditions. Recent improvements in the system have made it possible to obtain continuous measurements of respiratory gas exchange, cardiovascular function, and mineral balance for periods of up to 30 days on pig-tailed monkeys. It has also been possible to operate two pods which share one set of instrumentation, thereby permitting simultaneous measurements to be made on two animals by commutating signal outputs from the pods. In principle, more than two pods could be operated in this fashion. The system is compatible with Spacelab design. Representative physiological data from ground tests of the system are presented.
10 CFR 436.18 - Measuring cost-effectiveness.
Code of Federal Regulations, 2010 CFR
2010-01-01
... water system, considered in determining such matters as the optimal size of a solar energy system, the... building energy or water system with an energy or water conservation measure by retrofit to an existing... estimated payback time is significantly less than the useful life of that system, and of the Federal...
10 CFR 436.18 - Measuring cost-effectiveness.
Code of Federal Regulations, 2011 CFR
2011-01-01
... water system, considered in determining such matters as the optimal size of a solar energy system, the... building energy or water system with an energy or water conservation measure by retrofit to an existing... estimated payback time is significantly less than the useful life of that system, and of the Federal...
NASA Astrophysics Data System (ADS)
Gao, Mingxing; Jing, Hongwei; Cao, Xuedong; Chen, Lin; Yang, Jie
2015-08-01
When using the swing arm profilometer (SAP) to measure the aspheric mirror and the off-axis aspheric mirror, the error of the effective arm length of the SAP has an obvious influence on the measurement result. In order to reduce the influence of the effective arm length and increase the measurement accuracy of the SAP, the laser tracker is adopted to measure the effective arm length. Because the space position relationship of the probe system for the SAP is needed to measured before using the laser tracker, the point source microscope (PSM) is used to measure the space positional relationship. The measurement principle of the PSM and other applications are introduced; the accuracy and repeatability of this technology are analysed; the advantages and disadvantages of this technology are summarized.
Decoding carotid pressure waveforms recorded by laser Doppler vibrometry: Effects of rebreathing
NASA Astrophysics Data System (ADS)
Casaccia, Sara; Sirevaag, Erik J.; Richter, Edward; O'Sullivan, Joseph A.; Scalise, Lorenzo; Rohrbaugh, John W.
2014-05-01
The principal goal of this study was to assess the capability of the laser Doppler vibrometry (LDV) method for assessing cardiovascular activity. A rebreathing task was used to provoke changes within individuals in cardiac and vascular performance. The rebreathing task is known to produce multiple effects, associated with changes in autonomic drive as well as alterations in blood gases. The rise in CO2 (hypercapnia), in particular, produces changes in the cerebral and systemic circulation. The results from a rebreathing task (involving rebreathing the same air in a rubber bag) are presented for 35 individuals. The LDV pulse was measured from a site overlying the carotid artery. For comparison and validation purposes, several conventional measures of cardiovascular function were also obtained, with an emphasis on the electrocardiogram (ECG), continuous blood pressure (BP) from the radial artery, and measures of myocardial performance using impedance cardiography (ICG). During periods of active rebreathing, ventilation increased. The conventional cardiovascular effects included increased mean arterial BP and systemic vascular resistance, and decreased cardiac stroke volume (SV) and pulse transit time (PTT). These effects were consistent with a pattern of α-adrenergic stimulation. During the immediate post-rebreathing segments, in contrast, mean BP was largely unaffected but pulse BP increased, as did PTT and SV, whereas systemic vascular resistance decreased-a pattern consistent with β-adrenergic effects in combination with the direct effects of hypercapnia on the vascular system. Measures of cardiovascular activity derived from the LDV pulse velocity and displacement waveforms revealed patterns of changes that mirrored the results obtained using conventional measures. In particular, the ratio of the maximum early peak in the LDV velocity pulse to the maximum amplitude of the LDV displacement pulse (in an early systolic interval) closely mirrored the conventional SV effects. Additionally, changes in an augmentation ratio (computed as the maximum amplitude of the LDV displacement pulse during systole / amplitude at the end of the incident wave) were very similar to changes in systemic vascular resistance. Heart rates measured from the ECG and LDV were nearly identical. These preliminary results suggest that measures derived using the non-contact LDV technique can provide surrogate measures for those obtained using impedance cardiography.
Integrating Behavioral Technology into Public Schools.
ERIC Educational Resources Information Center
Axelrod, Saul
1993-01-01
Suggests seven measures that behavioral educators can take to make effective educational procedures available in public schools: make dissemination of effective technology first priority; develop comprehensive educational systems; simplify existing effective procedures; create market for effective educational technology; obtain new measures of…
Li, Wei; Wang, Hongbo; Feng, Zhihua
2016-04-01
This paper proposes an online, non-contact metal film thickness measurement system based on eddy current sensing. The slope of the lift-off curve (LOC) is used for characterizing target thickness. Theoretical derivation was conducted to prove that the slope is independent of the lift-off variation. In practice, the measurement has some immunity to the lift-off, but not perfect. The slope of LOC is still affected at some extent by the lift-off. Hence, a height tracking system was also proposed, which could stabilize the distance between the sensor and the target and significantly reduce the lift-off effect. The height tracking system contains a specially designed probe, which could vibrate rapidly to obtain a fast measurement speed, and its height can be adjusted up and down continuously to stabilize the lift-off. The sensor coil in the thickness measurement system was also used as the height sensor in the height tracking system. Several experiments were conducted to test the system performances under static and dynamic conditions. This measurement system demonstrated significant advantages, such as simple and clear conversion between the slope of LOC and target thickness, high resolution and stability, and minimized effect of lift-off variation.
Laser Self-Mixing Fiber Bragg Grating Sensor for Acoustic Emission Measurement.
Liu, Bin; Ruan, Yuxi; Yu, Yanguang; Xi, Jiangtao; Guo, Qinghua; Tong, Jun; Rajan, Ginu
2018-06-16
Fiber Bragg grating (FBG) is considered a good candidate for acoustic emission (AE) measurement. The sensing and measurement in traditional FBG-based AE systems are based on the variation in laser intensity induced by the Bragg wavelength shift. This paper presents a sensing system by combining self-mixing interference (SMI) in a laser diode and FBG for AE measurement, aiming to form a new compact and cost-effective sensing system. The measurement model of the overall system was derived. The performance of the presented system was investigated from both aspects of theory and experiment. The results show that the proposed system is able to measure AE events with high resolution and over a wide dynamic frequency range.
Experimental characterization of the effects of pneumatic tubing on unsteady pressure measurements
NASA Technical Reports Server (NTRS)
Whitmore, Stephen A.; Lindsey, William T.; Curry, Robert E.; Gilyard, Glenn B.
1990-01-01
Advances in aircraft control system designs have, with increasing frequency, required that air data be used as flight control feedback. This condition requires that these data be measured with accuracy and high fidelity. Most air data information is provided by pneumatic pressure measuring sensors. Typically unsteady pressure data provided by pneumatic sensing systems are distorted at high frequencies. The distortion is a result of the pressure being transmitted to the pressure sensor through a length of connective tubing. The pressure is distorted by frictional damping and wave reflection. As a result, air data provided all-flush, pneumatically sensed air data systems may not meet the frequency response requirements necessary for flight control augmentation. Both lab and flight test were performed at NASA-Ames to investigate the effects of this high frequency distortion in remotely located pressure measurement systems. Good qualitative agreement between lab and flight data are demonstrated. Results from these tests are used to describe the effects of pneumatic distortion in terms of a simple parametric model.
Dynamic State Estimation of Power Systems With Quantization Effects: A Recursive Filter Approach.
Hu, Liang; Wang, Zidong; Liu, Xiaohui
2016-08-01
In this paper, a recursive filter algorithm is developed to deal with the state estimation problem for power systems with quantized nonlinear measurements. The measurements from both the remote terminal units and the phasor measurement unit are subject to quantizations described by a logarithmic quantizer. Attention is focused on the design of a recursive filter such that, in the simultaneous presence of nonlinear measurements and quantization effects, an upper bound for the estimation error covariance is guaranteed and subsequently minimized. Instead of using the traditional approximation methods in nonlinear estimation that simply ignore the linearization errors, we treat both the linearization and quantization errors as norm-bounded uncertainties in the algorithm development so as to improve the performance of the estimator. For the power system with such kind of introduced uncertainties, a filter is designed in the framework of robust recursive estimation, and the developed filter algorithm is tested on the IEEE benchmark power system to demonstrate its effectiveness.
[Prevention of circulatory system diseases in underground mining workers].
Vlasova, E M; Alexeyev, M B; Shliapnikov, D M; Nosov, A E; Barannikov, V G
2015-01-01
The article covers results of preventive measures in workers engaged into underground mining. Those measures are aimed to prevent occupationally mediated health disorders resulting in circulatory diseases. The prophylaxis was proven effective on premorbid condition--that was demonstrated in reliable decrease of cause-effect relationship intensity for health disorders in workers subjected to prophylactic measures. Transitory disablement morbidity due to cicrulatory system diseases decreased. Situational modelling of risk changes for the studied group demonstrated changes of diseases risk under medical prophylactic measures. After the prophylaxis, the risk demonstrated 3.1 times decrease.
The Measurement Process in the Generalized Contexts Formalism for Quantum Histories
NASA Astrophysics Data System (ADS)
Losada, Marcelo; Vanni, Leonardo; Laura, Roberto
2016-02-01
In the interpretations of quantum mechanics involving quantum histories there is no collapse postulate and the measurement is considered as a quantum interaction between the measured system and the measured instrument. For two consecutive non ideal measurements on the same system, we prove that both pointer indications at the end of each measurement are compatible properties in our generalized context formalism for quantum histories. Inmediately after the first measurement an effective state for the measured system is deduced from the formalism, generalizing the state that would be obtained by applying the state collapse postulate.
Method for suppressing noise in measurements
NASA Technical Reports Server (NTRS)
Carson, Paul J. (Inventor); Madsen, Louis A. (Inventor); Leskowitz, Garett M. (Inventor); Weitekamp, Daniel P. (Inventor)
2000-01-01
Techniques of combining separate but correlated measurements to form a second-order or higher order correlation function to suppress the effects of noise in the initial condition of a system capable of retaining memory of an initial state of the system with a characteristic relaxation time. At least two separate measurements are obtained from the system. The temporal separation between the two separate measurements is preferably comparable to or less than the characteristic relaxation time and is adjusted to allow for a correlation between two measurements.
NASA Astrophysics Data System (ADS)
Lu, Cheng; Liu, Guodong; Liu, Bingguo; Chen, Fengdong; Zhuang, Zhitao; Xu, Xinke; Gan, Yu
2015-10-01
Absolute distance measurement systems are of significant interest in the field of metrology, which could improve the manufacturing efficiency and accuracy of large assemblies in fields such as aircraft construction, automotive engineering, and the production of modern windmill blades. Frequency scanning interferometry demonstrates noticeable advantages as an absolute distance measurement system which has a high precision and doesn't depend on a cooperative target. In this paper , the influence of inevitable vibration in the frequency scanning interferometry based absolute distance measurement system is analyzed. The distance spectrum is broadened as the existence of Doppler effect caused by vibration, which will bring in a measurement error more than 103 times bigger than the changes of optical path difference. In order to decrease the influence of vibration, the changes of the optical path difference are monitored by a frequency stabilized laser, which runs parallel to the frequency scanning interferometry. The experiment has verified the effectiveness of this method.
USDA-ARS?s Scientific Manuscript database
The objectives of these experiments were to characterize rumen motility patterns of cattle fed once daily using a real-time wireless telemetry system, determine when to measure rumen motility with this system, and determine the effect of ruminal dosing of ergot alkaloids on rumen motility. Ruminally...
Measurement device for high-precision spectral transmittance of solar blind filter
NASA Astrophysics Data System (ADS)
Wang, Yan; Qian, Yunsheng; Lv, Yang; Feng, Cheng; Liu, Jian
2017-02-01
In order to measure spectral transmittance of solar-blind filter ranging from ultraviolet to visible light accurately, a high-precision filter transmittance measuring system based on the ultraviolet photomultiplier is developed. The calibration method is mainly used to measure transmittance in this system, which mainly consists of an ultraviolet photomultiplier as core of the system and a lock-in amplifier combined with an optical modulator as the aided measurement for the system. The ultraviolet photomultiplier can amplify the current signal through the filter and have the characteristics of low dark current and high luminance gain. The optical modulator and the lock-in amplifier can obtain the signal from the photomultiplier and inhibit dark noise and spurious signal effectively. Through these two parts, the low light passing through the filters can be detected and we can calculate the transmittance by the optical power detected. Based on the proposed system, the limit detection of the transmittance can reach 10-12, while the result of the conventional approach is merely 10-6. Therefore, the system can make an effective assessment of solar blind ultraviolet filters.
Ganz, Jennifer B; Mason, Rose A; Goodwyn, Fara D; Boles, Margot B; Heath, Amy K; Davis, John L
2014-11-01
Individuals with autism spectrum disorders (ASD) and complex communication needs often rely on augmentative and alternative communication (AAC) as a means of functional communication. This meta-analysis investigated how individual characteristics moderate effectiveness of three types of aided AAC: the Picture Exchange Communication System (PECS), speech-generating devices (SGDs), and other picture-based AAC. Effectiveness was measured via the Improvement Rate Difference. Results indicated that AAC has small to moderate effects on speech outcomes, and that SGDs appear to be most effective when considering any outcome measure with individuals with ASD without comorbid intellectual/developmental disorders (IDD). PECS appears to be most effective when considering any outcome measure with individuals with ASD and IDD. SGDs and PECS were the most effective type of AAC for preschoolers, when aggregating across outcome measures. No difference was found between systems for elementary-aged and older individuals.
Determination of power system component parameters using nonlinear dead beat estimation method
NASA Astrophysics Data System (ADS)
Kolluru, Lakshmi
Power systems are considered the most complex man-made wonders in existence today. In order to effectively supply the ever increasing demands of the consumers, power systems are required to remain stable at all times. Stability and monitoring of these complex systems are achieved by strategically placed computerized control centers. State and parameter estimation is an integral part of these facilities, as they deal with identifying the unknown states and/or parameters of the systems. Advancements in measurement technologies and the introduction of phasor measurement units (PMU) provide detailed and dynamic information of all measurements. Accurate availability of dynamic measurements provides engineers the opportunity to expand and explore various possibilities in power system dynamic analysis/control. This thesis discusses the development of a parameter determination algorithm for nonlinear power systems, using dynamic data obtained from local measurements. The proposed algorithm was developed by observing the dead beat estimator used in state space estimation of linear systems. The dead beat estimator is considered to be very effective as it is capable of obtaining the required results in a fixed number of steps. The number of steps required is related to the order of the system and the number of parameters to be estimated. The proposed algorithm uses the idea of dead beat estimator and nonlinear finite difference methods to create an algorithm which is user friendly and can determine the parameters fairly accurately and effectively. The proposed algorithm is based on a deterministic approach, which uses dynamic data and mathematical models of power system components to determine the unknown parameters. The effectiveness of the algorithm is tested by implementing it to identify the unknown parameters of a synchronous machine. MATLAB environment is used to create three test cases for dynamic analysis of the system with assumed known parameters. Faults are introduced in the virtual test systems and the dynamic data obtained in each case is analyzed and recorded. Ideally, actual measurements are to be provided to the algorithm. As the measurements are not readily available the data obtained from simulations is fed into the determination algorithm as inputs. The obtained results are then compared to the original (or assumed) values of the parameters. The results obtained suggest that the algorithm is able to determine the parameters of a synchronous machine when crisp data is available.
SATCOM simulator speeds MSS deployment and lowers costs
NASA Technical Reports Server (NTRS)
Carey, Tim; Hassun, Roland; Koberstein, Dave
1993-01-01
Mobile satellite systems (MSS) are being proposed and licensed at an accelerating rate. How can the design, manufacture, and performance of these systems be optimized at costs that allow a reasonable return on investment? The answer is the use of system simulation techniques beginning early in the system design and continuing through integration, pre- and post-launch monitoring, and in-orbit monitoring. This paper focuses on using commercially available, validated simulation instruments to deliver accurate, repeatable, and cost effective measurements throughout the life of a typical mobile satellite system. A satellite communications test set is discussed that provides complete parametric test capability with a significant improvement in measurement speed for manufacturing, integration, and pre-launch and in-orbit testing. The test set can simulate actual up and down link traffic conditions to evaluate the effects of system impairments, propagation and multipath on bit error rate (BER), channel capacity and transponder and system load balancing. Using a standard set of commercial instruments to deliver accurate, verifiable measurements anywhere in the world speeds deployment, generates measurement confidence, and lowers total system cost.
Fault detection of helicopter gearboxes using the multi-valued influence matrix method
NASA Technical Reports Server (NTRS)
Chin, Hsinyung; Danai, Kourosh; Lewicki, David G.
1993-01-01
In this paper we investigate the effectiveness of a pattern classifying fault detection system that is designed to cope with the variability of fault signatures inherent in helicopter gearboxes. For detection, the measurements are monitored on-line and flagged upon the detection of abnormalities, so that they can be attributed to a faulty or normal case. As such, the detection system is composed of two components, a quantization matrix to flag the measurements, and a multi-valued influence matrix (MVIM) that represents the behavior of measurements during normal operation and at fault instances. Both the quantization matrix and influence matrix are tuned during a training session so as to minimize the error in detection. To demonstrate the effectiveness of this detection system, it was applied to vibration measurements collected from a helicopter gearbox during normal operation and at various fault instances. The results indicate that the MVIM method provides excellent results when the full range of faults effects on the measurements are included in the training set.
Presentation and response timing accuracy in Adobe Flash and HTML5/JavaScript Web experiments.
Reimers, Stian; Stewart, Neil
2015-06-01
Web-based research is becoming ubiquitous in the behavioral sciences, facilitated by convenient, readily available participant pools and relatively straightforward ways of running experiments: most recently, through the development of the HTML5 standard. Although in most studies participants give untimed responses, there is a growing interest in being able to record response times online. Existing data on the accuracy and cross-machine variability of online timing measures are limited, and generally they have compared behavioral data gathered on the Web with similar data gathered in the lab. For this article, we took a more direct approach, examining two ways of running experiments online-Adobe Flash and HTML5 with CSS3 and JavaScript-across 19 different computer systems. We used specialist hardware to measure stimulus display durations and to generate precise response times to visual stimuli in order to assess measurement accuracy, examining effects of duration, browser, and system-to-system variability (such as across different Windows versions), as well as effects of processing power and graphics capability. We found that (a) Flash and JavaScript's presentation and response time measurement accuracy are similar; (b) within-system variability is generally small, even in low-powered machines under high load; (c) the variability of measured response times across systems is somewhat larger; and (d) browser type and system hardware appear to have relatively small effects on measured response times. Modeling of the effects of this technical variability suggests that for most within- and between-subjects experiments, Flash and JavaScript can both be used to accurately detect differences in response times across conditions. Concerns are, however, noted about using some correlational or longitudinal designs online.
Changing drivers' minds: the evaluation of an advanced driver coaching system.
Stanton, N A; Walker, G H; Young, M S; Kazi, T; Salmon, P M
2007-08-01
This paper reports on the study of an advanced driver coaching system. The study distinguishes between different types of post-licensure programmes in order to explore a system based on a model of identifying and responding to hazards, called 'information, position, speed, gear and acceleration' (IPSGA). Previous literature has been sceptical about the benefits of advanced driver education; thus, the current study was designed to control for the effects of coaching drivers in the 'IPSGA' system (the treatment group) against the effects of being accompanied (control group 1), as well as the mere effects of time (control group 2). Measures were taken before the driver coaching began (as a baseline measure) and again after 8 weeks (to see if any changes had occurred). These measures included driver knowledge via a post-drive interview, observations of driving skill and driver attitude using a locus of control scale. The results suggest that advanced driver coaching using the IPSGA system had a beneficial effect on all of these measures. Drivers in the coaching condition improved their situation awareness, driving skills and reduced attributions of external locus of control. The study lends support to the case for one-to-one individualized driver coaching using a systematic model of driving.
DOT National Transportation Integrated Search
2014-11-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center, has developed an analytic model to measure the effectiveness of roadside inspections and traffic enforcements in te...
DOT National Transportation Integrated Search
2016-02-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National : Transportation Systems Center, has developed an analytic model to measure the effectiveness of roadside : inspections and traffic enforcements i...
DOT National Transportation Integrated Search
2017-08-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center, has developed an analytic model to measure the effectiveness of roadside inspections and traffic enforcements in te...
DOT National Transportation Integrated Search
2015-06-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center, has developed an analytic model to measure the effectiveness of roadside inspections and traffic enforcements in te...
ERIC Educational Resources Information Center
Herrmann, Mariesa; Ross, Christine
2016-01-01
States and districts across the country are implementing new principal evaluation systems that include measures of the quality of principals' school leadership practices and measures of student achievement growth. Because these evaluation systems will be used for high-stakes decisions, it is important that the component measures of the evaluation…
Jackson, Brian A; Faith, Kay Sullivan
2013-02-01
Although significant progress has been made in measuring public health emergency preparedness, system-level performance measures are lacking. This report examines a potential approach to such measures for Strategic National Stockpile (SNS) operations. We adapted an engineering analytic technique used to assess the reliability of technological systems-failure mode and effects analysis-to assess preparedness. That technique, which includes systematic mapping of the response system and identification of possible breakdowns that affect performance, provides a path to use data from existing SNS assessment tools to estimate likely future performance of the system overall. Systems models of SNS operations were constructed and failure mode analyses were performed for each component. Linking data from existing assessments, including the technical assistance review and functional drills, to reliability assessment was demonstrated using publicly available information. The use of failure mode and effects estimates to assess overall response system reliability was demonstrated with a simple simulation example. Reliability analysis appears an attractive way to integrate information from the substantial investment in detailed assessments for stockpile delivery and dispensing to provide a view of likely future response performance.
Measurement of Beam Tunes in the Tevatron Using the BBQ System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Edstrom, Dean R.; /Indiana U.
Measuring the betatron tunes in any synchrotron is of critical importance to ensuring the stability of beam in the synchrotron. The Base Band Tune, or BBQ, measurement system was developed by Marek Gasior of CERN and has been installed at Brookhaven and Fermilab as a part of the LHC Accelerator Research Program, or LARP. The BBQ was installed in the Tevatron to evaluate its effectiveness at reading proton and antiproton tunes at its flattop energy of 980 GeV. The primary objectives of this thesis are to examine the methods used to measure the tune using the BBQ tune measurement system,more » to incorporate the system into the Fermilab accelerator controls system, ACNET, and to compare the BBQ to existing tune measurement systems in the Tevatron.« less
Analysis of a document/reporting system
NASA Technical Reports Server (NTRS)
Narrow, B.
1971-01-01
An in-depth analysis of the information system within the Data Processing Branch is presented. Quantitative measures are used to evaluate the efficiency and effectiveness of the information system. It is believed that this is the first documented study which utilizes quantitative measures for full scale system analysis. The quantitative measures and techniques for collecting and qualifying the basic data, as described, are applicable to any information system. Therefore this report is considered to be of interest to any persons concerned with the management design, analysis or evaluation of information systems.
The in-situ 3D measurement system combined with CNC machine tools
NASA Astrophysics Data System (ADS)
Zhao, Huijie; Jiang, Hongzhi; Li, Xudong; Sui, Shaochun; Tang, Limin; Liang, Xiaoyue; Diao, Xiaochun; Dai, Jiliang
2013-06-01
With the development of manufacturing industry, the in-situ 3D measurement for the machining workpieces in CNC machine tools is regarded as the new trend of efficient measurement. We introduce a 3D measurement system based on the stereovision and phase-shifting method combined with CNC machine tools, which can measure 3D profile of the machining workpieces between the key machining processes. The measurement system utilizes the method of high dynamic range fringe acquisition to solve the problem of saturation induced by specular lights reflected from shiny surfaces such as aluminum alloy workpiece or titanium alloy workpiece. We measured two workpieces of aluminum alloy on the CNC machine tools to demonstrate the effectiveness of the developed measurement system.
A method to measure internal contact angle in opaque systems by magnetic resonance imaging.
Zhu, Weiqin; Tian, Ye; Gao, Xuefeng; Jiang, Lei
2013-07-23
Internal contact angle is an important parameter for internal wettability characterization. However, due to the limitation of optical imaging, methods available for contact angle measurement are only suitable for transparent or open systems. For most of the practical situations that require contact angle measurement in opaque or enclosed systems, the traditional methods are not effective. Based upon the requirement, a method suitable for contact angle measurement in nontransparent systems is developed by employing MRI technology. In the Article, the method is demonstrated by measuring internal contact angles in opaque cylindrical tubes. It proves that the method also shows great feasibility in transparent situations and opaque capillary systems. By using the method, contact angle in opaque systems could be measured successfully, which is significant in understanding the wetting behaviors in nontransparent systems and calculating interfacial parameters in enclosed systems.
Full-field 3D shape measurement of specular object having discontinuous surfaces
NASA Astrophysics Data System (ADS)
Zhang, Zonghua; Huang, Shujun; Gao, Nan; Gao, Feng; Jiang, Xiangqian
2017-06-01
This paper presents a novel Phase Measuring Deflectometry (PMD) method to measure specular objects having discontinuous surfaces. A mathematical model is established to directly relate the absolute phase and depth, instead of the phase and gradient. Based on the model, a hardware measuring system has been set up, which consists of a precise translating stage, a projector, a diffuser and a camera. The stage locates the projector and the diffuser together to a known position during measurement. By using the model-based and machine vision methods, system calibration is accomplished to provide the required parameters and conditions. The verification tests are given to evaluate the effectiveness of the developed system. 3D (Three-Dimensional) shapes of a concave mirror and a monolithic multi-mirror array having multiple specular surfaces have been measured. Experimental results show that the proposed method can obtain 3D shape of specular objects having discontinuous surfaces effectively
Development of Performance Dashboards in Healthcare Sector: Key Practical Issues.
Ghazisaeidi, Marjan; Safdari, Reza; Torabi, Mashallah; Mirzaee, Mahboobeh; Farzi, Jebraeil; Goodini, Azadeh
2015-10-01
Static nature of performance reporting systems in health care sector has resulted in inconsistent, incomparable, time consuming, and static performance reports that are not able to transparently reflect a round picture of performance and effectively support healthcare managers' decision makings. So, the healthcare sector needs interactive performance management tools such as performance dashboards to measure, monitor, and manage performance more effectively. The aim of this article was to identify key issues that need to be addressed for developing high-quality performance dashboards in healthcare sector. A literature review was established to search electronic research databases, e-journals collections, and printed journals, books, dissertations, and theses for relevant articles. The search strategy interchangeably used the terms of "dashboard", "performance measurement system", and "executive information system" with the term of "design" combined with operator "AND". Search results (n=250) were adjusted for duplications, screened based on their abstract relevancy and full-text availability (n=147) and then assessed for eligibility (n=40). Eligible articles were included if they had explicitly focused on dashboards, performance measurement systems or executive information systems design. Finally, 28 relevant articles included in the study. Creating high-quality performance dashboards requires addressing both performance measurement and executive information systems design issues. Covering these two fields, identified contents were categorized to four main domains: KPIs development, Data Sources and data generation, Integration of dashboards to source systems, and Information presentation issues. This study implies the main steps to develop dashboards for the purpose of performance management. Performance dashboards developed on performance measurement and executive information systems principles and supported by proper back-end infrastructure will result in creation of dynamic reports that help healthcare managers to consistently measure the performance, continuously detect outliers, deeply analyze causes of poor performance, and effectively plan for the future.
NASA Astrophysics Data System (ADS)
Stuffler, Timo; Graue, Roland; Bird, Antony J.; Dean, Antony; Staubert, Rüdiger
2018-04-01
This paper, "PIMACS (Polarimeter and improved modular anti-coincidence system): an effective instrument concept for x-, gamma-ray monitoring, and polarimetry measurements on the International Space Station," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.
ERIC Educational Resources Information Center
Munroe, Angela
2017-01-01
In this experimental study, music teachers from a large school district were randomly assigned to one of two hypothetical conditions reflecting different methods for measuring student growth under a merit pay compensation system. In Scenario A, half of a teacher's effectiveness rating was based on student standardized test scores in reading,…
International Symposium on Electromagnetic Compatibility, Wakefield, MA, August 20-22, 1985, Record
NASA Astrophysics Data System (ADS)
Various papers on electromagnetic compatibility are presented. The general topics addressed include: EMI transient/impulsive disturbances, electromagnetic shielding, antennas and propagation, measurement technology, anechoic chamber/open site measurements, communications systems, electrostatic discahrge, cables/transmission lines. Also considered are: elecromagnetic environments, antennas, electromagnetic pulse, nonlinear effect, computer/data transmission systems, EMI standards and requirements, enclosures/TEM cells, systems EMC, and test site measurements.
Watanabe, Takashi
2013-01-01
The wearable sensor system developed by our group, which measured lower limb angles using Kalman-filtering-based method, was suggested to be useful in evaluation of gait function for rehabilitation support. However, it was expected to reduce variations of measurement errors. In this paper, a variable-Kalman-gain method based on angle error that was calculated from acceleration signals was proposed to improve measurement accuracy. The proposed method was tested comparing to fixed-gain Kalman filter and a variable-Kalman-gain method that was based on acceleration magnitude used in previous studies. First, in angle measurement in treadmill walking, the proposed method measured lower limb angles with the highest measurement accuracy and improved significantly foot inclination angle measurement, while it improved slightly shank and thigh inclination angles. The variable-gain method based on acceleration magnitude was not effective for our Kalman filter system. Then, in angle measurement of a rigid body model, it was shown that the proposed method had measurement accuracy similar to or higher than results seen in other studies that used markers of camera-based motion measurement system fixing on a rigid plate together with a sensor or on the sensor directly. The proposed method was found to be effective in angle measurement with inertial sensors. PMID:24282442
Solar radiation alert system : final report.
DOT National Transportation Integrated Search
2009-03-01
The Solar Radiation Alert (SRA) system continuously evaluates measurements of high-energy protons made by instruments on GOES satellites. If the measurements indicate a substantial elevation of effective dose rates at aircraft flight altitudes, the C...
Models and techniques for evaluating the effectiveness of aircraft computing systems
NASA Technical Reports Server (NTRS)
Meyer, J. F.
1978-01-01
The development of system models that can provide a basis for the formulation and evaluation of aircraft computer system effectiveness, the formulation of quantitative measures of system effectiveness, and the development of analytic and simulation techniques for evaluating the effectiveness of a proposed or existing aircraft computer are described. Specific topics covered include: system models; performability evaluation; capability and functional dependence; computation of trajectory set probabilities; and hierarchical modeling of an air transport mission.
Hunter versus CIE color measurement systems for analysis of milk-based beverages.
Cheng, Ni; Barbano, David M; Drake, Mary Anne
2018-06-01
The objective of our work was to determine the differences in sensitivity of Hunter and International Commission on Illumination (CIE) methods at 2 different viewer angles (2 and 10°) for measurement of whiteness, red/green, and blue/yellow color of milk-based beverages over a range of composition. Sixty combinations of milk-based beverages were formulated (2 replicates) with a range of fat level from 0.2 to 2%, true protein level from 3 to 5%, and casein as a percent of true protein from 5 to 80% to provide a wide range of milk-based beverage color. In addition, commercial skim, 1 and 2% fat high-temperature, short-time pasteurized fluid milks were analyzed. All beverage formulations were HTST pasteurized and cooled to 4°C before analysis. Color measurement viewer angle (2 vs. 10°) had very little effect on objective color measures of milk-based beverages with a wide range of composition for either the Hunter or CIE color measurement system. Temperature (4, 20, and 50°C) of color measurement had a large effect on the results of color measurement in both the Hunter and CIE measurement systems. The effect of milk beverage temperature on color measurement results was the largest for skim milk and the least for 2% fat milk. This highlights the need for proper control of beverage serving temperature for sensory panel analysis of milk-based beverages with very low fat content and for control of milk temperature when doing objective color analysis for quality control in manufacture of milk-based beverages. The Hunter system of color measurement was more sensitive to differences in whiteness among milk-based beverages than the CIE system, whereas the CIE system was much more sensitive to differences in yellowness among milk-based beverages. There was little difference between the Hunter and CIE system in sensitivity to green/red color of milk-based beverages. In defining milk-based beverage product specifications for objective color measures for dairy product manufacturers, the viewer angle, color measurement system (CIE vs. Hunter), and sample measurement temperature should be specified along with type of illuminant. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Comparative Effects of Antihistamines on Aircrew Mission Effectiveness under Sustained Operations
1992-06-01
measures consist mainly of process measures. Process measures are measures of activities used to accomplish the mission and produce the final results...They include task completion times and response variability, and information processing rates as they relate to unique task assignment. Performance...contains process measures that assess the Individual contributions of hardware/software and human components to overall system performance. Measures
DOT National Transportation Integrated Search
2017-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
ERIC Educational Resources Information Center
Hushman, Glenn; Hushman, Carolyn; Carbonneau, Kira
2015-01-01
The current educational reform movement in the United States is focused on measuring the effectiveness of teachers. One component of teacher effectiveness is student achievement. The effectiveness of using PE Metrics as a measure of student achievement in a physical activity setting with a low socioeconomic, culturally diverse population was…
Bevan, Gwyn; Hamblin, Richard
2009-01-01
Following devolution, differences developed between UK countries in systems of measuring performance against a common target that ambulance services ought to respond to 75% of calls for what may be immediately life threatening emergencies (category A calls) within 8 minutes. Only in England was this target integral to a ranking system of ‘star rating’, which inflicted reputational damage on services that failed to hit targets, and only in England has this target been met. In other countries, the target has been missed by such large margins that services would have been publicly reported as failing, if they had been covered by the English system of star ratings. The paper argues that this case-study adds to evidence from comparisons of different systems of hospital performance measurement that, to have an effect, these systems need to be designed to inflict reputational damage on those that have performed poorly; and it explores implications of this hypothesis. The paper also asks questions about the adequacy of systems of performance measurement of ambulance services in UK countries. PMID:19381327
System for Measuring Conditional Amplitude, Phase, or Time Distributions of Pulsating Phenomena
Van Brunt, Richard J.; Cernyar, Eric W.
1992-01-01
A detailed description is given of an electronic stochastic analyzer for use with direct “real-time” measurements of the conditional distributions needed for a complete stochastic characterization of pulsating phenomena that can be represented as random point processes. The measurement system described here is designed to reveal and quantify effects of pulse-to-pulse or phase-to-phase memory propagation. The unraveling of memory effects is required so that the physical basis for observed statistical properties of pulsating phenomena can be understood. The individual unique circuit components that comprise the system and the combinations of these components for various measurements, are thoroughly documented. The system has been applied to the measurement of pulsating partial discharges generated by applying alternating or constant voltage to a discharge gap. Examples are shown of data obtained for conditional and unconditional amplitude, time interval, and phase-of-occurrence distributions of partial-discharge pulses. The results unequivocally show the existence of significant memory effects as indicated, for example, by the observations that the most probable amplitudes and phases-of-occurrence of discharge pulses depend on the amplitudes and/or phases of the preceding pulses. Sources of error and fundamental limitations of the present measurement approach are analyzed. Possible extensions of the method are also discussed. PMID:28053450
Measurement control workshop instructional materials
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gibbs, Philip; Harvel, Charles; Clark, John
2012-09-01
An essential element in an effective nuclear materials control and accountability (MC&A) program is the measurement of the nuclear material as it is received, moved, processed and shipped. Quality measurement systems and methodologies determine the accuracy of the accountability values. Implementation of a measurement control program is essential to ensure that the measurement systems and methodologies perform as expected. A measurement control program also allows for a determination of the level of confidence in the accounting values.
Seat belt use-inducing system effectiveness
DOT National Transportation Integrated Search
1975-04-01
Seat belt use inducing system effectiveness was measured in fleet automobiles of a private business and in rental automobiles at a large airport. There were three parts to the activity: 1. Seat belt use inducing systems and seat belt use counting sys...
Safety belt interlock system usage survey
DOT National Transportation Integrated Search
1976-08-01
This research is intended to measure the effectiveness of various use-inducing systems in increasing safety belt usage. Specifically, the objectives are: (1) to determine if the 1975 warning system issued in response to P.L. 93-492 is effective in in...
NASA Astrophysics Data System (ADS)
Zhao, Ziyue; Gan, Xiaochuan; Zou, Zhi; Ma, Liqun
2018-01-01
The dynamic envelope measurement plays very important role in the external dimension design for high-speed train. Recently there is no digital measurement system to solve this problem. This paper develops an optoelectronic measurement system by using monocular digital camera, and presents the research of measurement theory, visual target design, calibration algorithm design, software programming and so on. This system consists of several CMOS digital cameras, several luminous targets for measuring, a scale bar, data processing software and a terminal computer. The system has such advantages as large measurement scale, high degree of automation, strong anti-interference ability, noise rejection and real-time measurement. In this paper, we resolve the key technology such as the transformation, storage and calculation of multiple cameras' high resolution digital image. The experimental data show that the repeatability of the system is within 0.02mm and the distance error of the system is within 0.12mm in the whole workspace. This experiment has verified the rationality of the system scheme, the correctness, the precision and effectiveness of the relevant methods.
Davis, Ben; Grosvenor, Chriss; Johnk, Robert; Novotny, David; Baker-Jarvis, James; Janezic, Michael
2007-01-01
Building materials are often incorporated into complex, multilayer macrostructures that are simply not amenable to measurements using coax or waveguide sample holders. In response to this, we developed an ultra-wideband (UWB) free-field measurement system. This measurement system uses a ground-plane-based system and two TEM half-horn antennas to transmit and receive the RF signal. The material samples are placed between the antennas, and reflection and transmission measurements made. Digital signal processing techniques are then applied to minimize environmental and systematic effects. The processed data are compared to a plane-wave model to extract the material properties with optimization software based on genetic algorithms.
A simple 5-DoF MR-compatible motion signal measurement system.
Chung, Soon-Cheol; Kim, Hyung-Sik; Yang, Jae-Woong; Lee, Su-Jeong; Choi, Mi-Hyun; Kim, Ji-Hye; Yeon, Hong-Won; Park, Jang-Yeon; Yi, Jeong-Han; Tack, Gye-Rae
2011-09-01
The purpose of this study was to develop a simple motion measurement system with magnetic resonance (MR) compatibility and safety. The motion measurement system proposed here can measure 5-DoF motion signals without deteriorating the MR images, and it has no effect on the intense and homogeneous main magnetic field, the temporal-gradient magnetic field (which varies rapidly with time), the transceiver radio frequency (RF) coil, and the RF pulse during MR data acquisition. A three-axis accelerometer and a two-axis gyroscope were used to measure 5-DoF motion signals, and Velcro was used to attach a sensor module to a finger or wrist. To minimize the interference between the MR imaging system and the motion measurement system, nonmagnetic materials were used for all electric circuit components in an MR shield room. To remove the effect of RF pulse, an amplifier, modulation circuit, and power supply were located in a shielded case, which was made of copper and aluminum. The motion signal was modulated to an optic signal using pulse width modulation, and the modulated optic signal was transmitted outside the MR shield room using a high-intensity light-emitting diode and an optic cable. The motion signal was recorded on a PC by demodulating the transmitted optic signal into an electric signal. Various kinematic variables, such as angle, acceleration, velocity, and jerk, can be measured or calculated by using the motion measurement system developed here. This system also enables motion tracking by extracting the position information from the motion signals. It was verified that MR images and motion signals could reliably be measured simultaneously.
NASA Astrophysics Data System (ADS)
Yang, Bo; Wang, Dehui; Zhou, Lin; Wu, Shuang; Xiang, Rong; Zhang, Wenhua; Gui, Huaqiao; Liu, Jianguo; Wang, Huanqing; Lu, Liang; Yu, Benli
2017-06-01
The self-mixing technique based on the traditional reflecting mirror has been demonstrated with great merit for angle sensing applications. Here we demonstrate a modified self-reflection-mixing angle measurement system by combine a right-angle prism to self-mixing angle measurement. In our system, the wavelength is crucial to the angle measurement resolution. For a microchip solid-state laser, the measurement resolution can reach 0.49 mrad, while the resolution for the He-Ne laser is 0.53 mrad. In addition, the ranges in the system with the microchip solid-state laser and He-Ne laser are up to 22 mrad and 24.9 mrad respectively. This modified angle measurement system effectively combines the advantage of self-mixing measurement system with a compact structure, providing interesting features such as of high requisition of resolution and precision.
NASA Astrophysics Data System (ADS)
The present conference discusses topics in EM shielding effectiveness, system-level EMC, EMP effects, circuit-level EMI testing, EMI control, analysis techniques for system-level EMC, EMP protective measures, EMI test methods, electrostatic-discharge testing, printed circuit-board design for EMC, and EM environment effects. Also discussed are EMI measurement procedures, EM spectrum-management issues for the 21st century, antenna and propagation effects on EMI testing, EMI control in cables, socioeconomic aspects of EMC, systemwide EMI controls, and EM radiation and coupling.
A Differential Polarized Light Interferometric System For Measuring Flatness Of Magnetic Disks
NASA Astrophysics Data System (ADS)
Jia, Wang; Da-Cheng, Li; Ye, Chen; Ling, Du; Mang, Cao
1987-01-01
A kind of differential polarizdd laser interferometric system for non-contact and dynamic measurement of the flatness characteristic of magnetic disks without the effect of the axial vibration is described in this papper.
C3 generic workstation: Performance metrics and applications
NASA Technical Reports Server (NTRS)
Eddy, Douglas R.
1988-01-01
The large number of integrated dependent measures available on a command, control, and communications (C3) generic workstation under development are described. In this system, embedded communications tasks will manipulate workload to assess the effects of performance-enhancing drugs (sleep aids and decongestants), work/rest cycles, biocybernetics, and decision support systems on performance. Task performance accuracy and latency will be event coded for correlation with other measures of voice stress and physiological functioning. Sessions will be videotaped to score non-verbal communications. Physiological recordings include spectral analysis of EEG, ECG, vagal tone, and EOG. Subjective measurements include SWAT, fatigue, POMS and specialized self-report scales. The system will be used primarily to evaluate the effects on performance of drugs, work/rest cycles, and biocybernetic concepts. Performance assessment algorithms will also be developed, including those used with small teams. This system provides a tool for integrating and synchronizing behavioral and psychophysiological measures in a complex decision-making environment.
Problems of systems dataware using optoelectronic measuring means of linear displacement
NASA Astrophysics Data System (ADS)
Bazykin, S. N.; Bazykina, N. A.; Samohina, K. S.
2017-10-01
Problems of the dataware of the systems with the use of optoelectronic means of the linear displacement are considered in the article. The classification of the known physical effects, realized by the means of information-measuring systems, is given. The organized analysis of information flows in technical systems from the standpoint of determination of inaccuracies of measurement and management was conducted. In spite of achieved successes in automation of machine-building and instruments-building equipment in the field of dataware of the technical systems, there are unresolved problems, concerning the qualitative aspect of the production process. It was shown that the given problem can be solved using optoelectronic lazer information-measuring systems. Such information-measuring systems are capable of not only executing the measuring functions, but also solving the problems of management and control during processing, thereby guaranteeing the quality of final products.
Measurement of remote micro vibration based on laser feedback interference
NASA Astrophysics Data System (ADS)
Wu, Peng; Qin, Shuijie; Xu, Ning
2018-03-01
The method of remote micro-vibration measurement is studied and presented based on the laser feedback effect in this paper, and the key factors of remote vibration measurement are analyzed. The vibration measurement system is designed and built based on the laser feedback and the research of the remote micro vibration measurement is carried out. The system has ultrahigh measuring sensitivity and the working distance is 25 meters, which can measure the vibration of non-cooperative target. The system has the capability to realize the non-contact measurement of remote micro-vibration at different driving signals and can fulfill the complex vibration measurement and reproduction of multiple frequencies. It can identify the voice signal and the voice signal reproduced is clear to hear. The system can meet various requirements of vibration measurement and has great significance in practical application.
NASA Astrophysics Data System (ADS)
Fleming, Rex J.
2003-09-01
The challenge of obtaining an adequate environmental support system to help mitigate the effects of various terrorist generated plumes is articulated and a fiscally responsible solution is presented. A substantially improved national system of upper air data observing systems serves as a powerful information source prior to a terrorist event. A mobile tactical observing system for measuring the environment and for measuring the composition and intensity of the plume is implemented immediately following an event. Only proven and tested technologies are used. Program costs, benefits for the fight against terrorism, and multiple benefits to other aspects of the economy are summarized.
NASA Astrophysics Data System (ADS)
Zhang, Xiaofei; Ye, Xuan; Li, Xide
2016-08-01
In this paper, we present a cantilever-probe system excited by a piezoelectric actuator, and use it to measure the dynamic mechanical properties of a micro- and nanoscale fiber. Coupling the fiber to the free end of the cantilever probe, we found the dynamic stiffness and damping coefficient of the fiber from the resonance frequency and the quality factor of the fiber-cantilever-probe system. The properties of Bacillus subtilis fibers measured using our proposed system agreed with tensile measurements, validating our method. Our measurements show that the piezoelectric actuator coupled to cantilever probe can be made equivalent to a clamped cantilever with an effective length, and calculated results show that the errors of measured natural frequency of the system can be ignored if the coupled fiber has an inclination angle of alignment of less than 10°. A sensitivity analysis indicates that the first or second resonant mode is the sensitive mode to test the sample’s dynamic stiffness, while the damping property has different sensitivities for the first four modes. Our theoretical analysis demonstrates that the double-cantilever probe is also an effective sensitive structure that can be used to perform dynamic loading and characterize dynamic response. Our method has the advantage of using amplitude-frequency curves to obtain the dynamic mechanical properties without directly measuring displacements and forces as in tensile tests, and it also avoids the effects of the complex surface structure and deformation presenting in contact resonance method. Our method is effective for measuring the dynamic mechanical properties of fiber-like one-dimensional (1D) materials.
Performance analysis and evaluation of direct phase measuring deflectometry
NASA Astrophysics Data System (ADS)
Zhao, Ping; Gao, Nan; Zhang, Zonghua; Gao, Feng; Jiang, Xiangqian
2018-04-01
Three-dimensional (3D) shape measurement of specular objects plays an important role in intelligent manufacturing applications. Phase measuring deflectometry (PMD)-based methods are widely used to obtain the 3D shapes of specular surfaces because they offer the advantages of a large dynamic range, high measurement accuracy, full-field and noncontact operation, and automatic data processing. To enable measurement of specular objects with discontinuous and/or isolated surfaces, a direct PMD (DPMD) method has been developed to build a direct relationship between phase and depth. In this paper, a new virtual measurement system is presented and is used to optimize the system parameters and evaluate the system's performance in DPMD applications. Four system parameters are analyzed to obtain accurate measurement results. Experiments are performed using simulated and actual data and the results confirm the effects of these four parameters on the measurement results. Researchers can therefore select suitable system parameters for actual DPMD (including PMD) measurement systems to obtain the 3D shapes of specular objects with high accuracy.
Measurement of unsteady pressures in rotating systems
NASA Technical Reports Server (NTRS)
Kienappel, K.
1978-01-01
The principles of the experimental determination of unsteady periodic pressure distributions in rotating systems are reported. An indirect method is discussed, and the effects of the centrifugal force and the transmission behavior of the pressure measurement circuit were outlined. The required correction procedures are described and experimentally implemented in a test bench. Results show that the indirect method is suited to the measurement of unsteady nonharmonic pressure distributions in rotating systems.
Drag balance Cubesat attitude motion effects on in-situ thermosphere density measurements
NASA Astrophysics Data System (ADS)
Felicetti, Leonard; Santoni, Fabio
2014-08-01
The dynamics of Cubesats carrying a drag balance instrument (DBI) for in situ atmosphere density measurements is analyzed. Atmospheric drag force is measured by the displacement of two light plates exposed to the incoming particle flow. This system is well suited for a distributed sensor network in orbit, to get simultaneous in situ local (non orbit averaged) measurements in multiple positions and orbit heights, contributing to the development and validation of global atmosphere models. The implementation of the DBI leads to orbit normal pointing spinning two body system. The use of a spin-magnetic attitude control system is suggested, based only on magnetometer readings, contributing to making the system simple, inexpensive, and reliable. It is shown, by an averaging technique, that this system provides for orbit normal spin axis pointing. The effect of the coupling between the attitude dynamics and the DBI is evaluated, analyzing its frequency content and showing that no frequency components arise, affecting the DBI performance. The analysis is confirmed by Monte Carlo numerical simulation results.
A system for the real time, direct measurement of natural gas flow
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sowell, T.
1995-12-31
PMI/Badger Meter, Inc. with partial sponsorship from the Gas Research Institute, has designed and developed direct measurement total energy flow metering instrumentation. As industry demands for improved accuracy and speed of measurement have increased so has the complexity of the overall hardware and software systems. Considering traditional system approaches, few companies have the in house capability of maintaining a complete system. This paper addresses efforts to implement a direct, total gas energy flow metering system which is simple to use and cost effective.
The effectiveness of sentence cues in measuring the Big Three motives.
Langan-Fox, Janice; Grant, Sharon
2007-10-01
Despite the popularity of free response measures in the motivation literature, research geared toward the development of a standard battery of cues for measuring the Big Three motives (achievement, affiliation, power) has been lacking. The current research examined the effectiveness of sentence cues in eliciting motive imagery in two studies (students, entrepreneurs) comprising 242 men and women. Results indicated that sentence cues were effective in eliciting achievement and affiliation imagery, but not power imagery. In addition, an examination of the subcategories underlying each motive scoring system indicated that there were several infrequently scored subcategories in the achievement and power motive scoring systems that could be considered for removal.
Nap environment control considering respiration rate and music tempo by using sensor agent robot
NASA Astrophysics Data System (ADS)
Nakaso, Sayaka; Mita, Akira
2015-03-01
We propose a system that controls a nap environment considering respiration rates and music tempo by using a sensor agent robot. The proposed system consists of two sub-systems. The first sub-system measures respiration rates using optical flow. We conducted preparatory experiments to verify the accuracy of this sub-system. The experimental results showed that this sub-system can measure the respiration rates accurately despite several positional relationships. It was also shown that the accuracy could be affected by clothes, movements and light. The second sub-system we constructed was the music play sub-system that chooses music with the certain tempo corresponding to the respiration rates measured by the first sub-system. We conducted verification experiments to verify the effectiveness of this music play sub-system. The experimental results showed the effectiveness of varying music tempo based on the respiration rates in taking a nap. We also demonstrated this system in a real environment; a subject entered into the room being followed by ebioNα. When the subject was considered sleeping, ebioNα started measuring respiration rates, controlling music based on the respiration rates. As a result, we showed that this system could be realized. As a next step, we would like to improve this system to a nap environment control system to be used in offices. To realize this, we need to update the first sub-system measuring respiration rates by removing disturbances. We also need to upgrade music play sub-system considering the numbers of tunes, the kinds of music and time to change music.
Tactical Aviation Mission System Simulation Situational Awareness Project
2004-04-01
prototyping and exercising human-machine systems and for measuring the impact of new technologies in a dynamic simulation environment. Theoretical...31 2.4.1 The Impact of an ERSTA-Like System on the CH-146 Mission Commander...was proven to be an effective platform for prototyping and exercising systems and for measuring the impact of new technologies in a dynamic simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, Scott A; Catalfamo, Simone; Brake, Matthew R. W.
2017-01-01
In the study of the dynamics of nonlinear systems, experimental measurements often convolute the response of the nonlinearity of interest and the effects of the experimental setup. To reduce the influence of the experimental setup on the deduction of the parameters of the nonlinearity, the response of a mechanical joint is investigated under various experimental setups. These experiments first focus on quantifying how support structures and measurement techniques affect the natural frequency and damping of a linear system. The results indicate that support structures created from bungees have negligible influence on the system in terms of frequency and damping ratiomore » variations. The study then focuses on the effects of the excitation technique on the response for a linear system. The findings suggest that thinner stingers should not be used, because under the high force requirements the stinger bending modes are excited adding unwanted torsional coupling. The optimal configuration for testing the linear system is then applied to a nonlinear system in order to assess the robustness of the test configuration. Finally, recommendations are made for conducting experiments on nonlinear systems using conventional/linear testing techniques.« less
Flexible coordinate measurement system based on robot for industries
NASA Astrophysics Data System (ADS)
Guo, Yin; Yang, Xue-you; Liu, Chang-jie; Ye, Sheng-hua
2010-10-01
The flexible coordinate measurement system based on robot which is applicable to multi-model vehicle is designed to meet the needs of online measurement for current mainstream mixed body-in-white(BIW) production line. The moderate precision, good flexibility and no blind angle are the benefits of this measurement system. According to the measurement system, a monocular structured light vision sensor has been designed, which can measure not only edges, but also planes, apertures and other features. And a effective way to fast on-site calibration of the whole system using the laser tracker has also been proposed, which achieves the unity of various coordinate systems in industrial fields. The experimental results show satisfactory precision of +/-0.30mm of this measurement system, which is sufficient for the needs of online measurement for body-in-white(BIW) in the auto production line. The system achieves real-time detection and monitoring of the whole process of the car body's manufacture, and provides a complete data support in purpose of overcoming the manufacturing error immediately and accurately and improving the manufacturing precision.
NASA Astrophysics Data System (ADS)
Tian, Qijie; Chang, Songtao; Li, Zhou; He, Fengyun; Qiao, Yanfeng
2017-03-01
The suppression level of internal stray radiation is a key criterion for infrared imaging systems, especially for high-precision cryogenic infrared imaging systems. To achieve accurate measurement for internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures, a measurement method, which is based on radiometric calibration, is presented in this paper. First of all, the calibration formula is deduced considering the integration time, and the effect of ambient temperature on internal stray radiation is further analyzed in detail. Then, an approach is proposed to measure the internal stray radiation of cryogenic infrared imaging systems under various ambient temperatures. By calibrating the system under two ambient temperatures, the quantitative relation between the internal stray radiation and the ambient temperature can be acquired, and then the internal stray radiation of the cryogenic infrared imaging system under various ambient temperatures can be calculated. Finally, several experiments are performed in a chamber with controllable inside temperatures to evaluate the effectiveness of the proposed method. Experimental results indicate that the proposed method can be used to measure internal stray radiation with high accuracy at various ambient temperatures and integration times. The proposed method has some advantages, such as simple implementation and the capability of high-precision measurement. The measurement results can be used to guide the stray radiation suppression and to test whether the internal stray radiation suppression performance meets the requirement or not.
Measurement of greenhouse gases in UAE by using Unmanned Aerial Vehicle (UAV)
NASA Astrophysics Data System (ADS)
Abou-Elnour, Ali; Odeh, Mohamed; Abdelrhman, Mohammed; Balkis, Ahmed; Amira, Abdelraouf
2017-04-01
In the present work, a reliable and low cost system has been designed and implemented to measure greenhouse gases (GHG) in United Arab Emirates (UAE) by using unmanned aerial vehicle (UAV). A set of accurate gas, temperature, pressure, humidity sensors are integrated together with a wireless communication system on a microcontroller based platform to continuously measure the required data. The system instantaneously sends the measured data to a center monitoring unit via the wireless communication system. In addition, the proposed system has the features that all measurements are recorded directly in a storage device to allow effective monitoring in regions with weak or no wireless coverage. The obtained data will be used in all further sophisticated calculations for environmental research and monitoring purposes.
Larval salamander growth responds to enrichment of a nutrient poor headwater stream
Brent J. Johnson; J. Bruce Wallace; AmyD Rosemond; Wyatt F. Cross
2006-01-01
While many studies have measured effects of nutrient enrichment on higher trophic levels in grazing food webs, few such studies exist for detritus-based systems. We measured effects of nitrogen and...
Artificial Intelligence Measurement System, Overview and Lessons Learned. Final Project Report.
ERIC Educational Resources Information Center
Baker, Eva L.; Butler, Frances A.
This report summarizes the work conducted for the Artificial Intelligence Measurement System (AIMS) Project which was undertaken as an exploration of methodology to consider how the effects of artificial intelligence systems could be compared to human performance. The research covered four areas of inquiry: (1) natural language processing and…
Glenys Jones
2015-01-01
This paper describes the Australian State of Tasmania's management effectiveness Monitoring and Reporting System for national parks and reserves. This jurisdictional performance measurement system is designed to provide all interested parties with reliable factual information and measured evidence about reserve management achievements, progress and challenges. Key...
Uncertainty Analysis of Seebeck Coefficient and Electrical Resistivity Characterization
NASA Technical Reports Server (NTRS)
Mackey, Jon; Sehirlioglu, Alp; Dynys, Fred
2014-01-01
In order to provide a complete description of a materials thermoelectric power factor, in addition to the measured nominal value, an uncertainty interval is required. The uncertainty may contain sources of measurement error including systematic bias error and precision error of a statistical nature. The work focuses specifically on the popular ZEM-3 (Ulvac Technologies) measurement system, but the methods apply to any measurement system. The analysis accounts for sources of systematic error including sample preparation tolerance, measurement probe placement, thermocouple cold-finger effect, and measurement parameters; in addition to including uncertainty of a statistical nature. Complete uncertainty analysis of a measurement system allows for more reliable comparison of measurement data between laboratories.
NASA Astrophysics Data System (ADS)
Yalcin, A.; Olgar, T.
2018-07-01
The aim of this study was to assess the performance of a digital radiography system in terms of effective detective quantum efficiency (eDQE) for different tube voltages, polymethyl methacrylate (PMMA) phantom thicknesses and different grid types. The image performance of the digital radiography system was also evaluated by using CDRAD measurements at the same conditions and the correlation of CDRAD results with eDQE was compared. The eDQE was calculated via measurement of effective modulation transfer function (eMTF), effective normalized noise power spectra (eNNPS), scatter fraction (SF) and transmission factors (TF). SFs and TFs were also calculated for different beam qualities by using MCNP4C Monte Carlo simulation code. The integrated eDQE (IeDQE) over the frequency range was used to find the correlation with the inverse image quality figure (IQFinv) obtained from CDRAD measurements. The highest eDQE was obtained with 60 lp/cm grid frequency and 10:1 grid ratio. No remarkable effect was observed on eDQE with different grid frequency, but eDQE decreased with increasing grid ratio. A significant correlation was found between IeDQE and IQFinv.
Measurement system and model for simultaneously measuring 6DOF geometric errors.
Zhao, Yuqiong; Zhang, Bin; Feng, Qibo
2017-09-04
A measurement system to simultaneously measure six degree-of-freedom (6DOF) geometric errors is proposed. The measurement method is based on a combination of mono-frequency laser interferometry and laser fiber collimation. A simpler and more integrated optical configuration is designed. To compensate for the measurement errors introduced by error crosstalk, element fabrication error, laser beam drift, and nonparallelism of two measurement beam, a unified measurement model, which can improve the measurement accuracy, is deduced and established using the ray-tracing method. A numerical simulation using the optical design software Zemax is conducted, and the results verify the correctness of the model. Several experiments are performed to demonstrate the feasibility and effectiveness of the proposed system and measurement model.
Development of a wireless displacement measurement system using acceleration responses.
Park, Jong-Woong; Sim, Sung-Han; Jung, Hyung-Jo; Spencer, Billie F
2013-07-01
Displacement measurements are useful information for various engineering applications such as structural health monitoring (SHM), earthquake engineering and system identification. Most existing displacement measurement methods are costly, labor-intensive, and have difficulties particularly when applying to full-scale civil structures because the methods require stationary reference points. Indirect estimation methods converting acceleration to displacement can be a good alternative as acceleration transducers are generally cost-effective, easy to install, and have low noise. However, the application of acceleration-based methods to full-scale civil structures such as long span bridges is challenging due to the need to install cables to connect the sensors to a base station. This article proposes a low-cost wireless displacement measurement system using acceleration. Developed with smart sensors that are low-cost, wireless, and capable of on-board computation, the wireless displacement measurement system has significant potential to impact many applications that need displacement information at multiple locations of a structure. The system implements an FIR-filter type displacement estimation algorithm that can remove low frequency drifts typically caused by numerical integration of discrete acceleration signals. To verify the accuracy and feasibility of the proposed system, laboratory tests are carried out using a shaking table and on a three storey shear building model, experimentally confirming the effectiveness of the proposed system.
Development of a Wireless Displacement Measurement System Using Acceleration Responses
Park, Jong-Woong; Sim, Sung-Han; Jung, Hyung-Jo; Spencer, Billie F.
2013-01-01
Displacement measurements are useful information for various engineering applications such as structural health monitoring (SHM), earthquake engineering and system identification. Most existing displacement measurement methods are costly, labor-intensive, and have difficulties particularly when applying to full-scale civil structures because the methods require stationary reference points. Indirect estimation methods converting acceleration to displacement can be a good alternative as acceleration transducers are generally cost-effective, easy to install, and have low noise. However, the application of acceleration-based methods to full-scale civil structures such as long span bridges is challenging due to the need to install cables to connect the sensors to a base station. This article proposes a low-cost wireless displacement measurement system using acceleration. Developed with smart sensors that are low-cost, wireless, and capable of on-board computation, the wireless displacement measurement system has significant potential to impact many applications that need displacement information at multiple locations of a structure. The system implements an FIR-filter type displacement estimation algorithm that can remove low frequency drifts typically caused by numerical integration of discrete acceleration signals. To verify the accuracy and feasibility of the proposed system, laboratory tests are carried out using a shaking table and on a three storey shear building model, experimentally confirming the effectiveness of the proposed system. PMID:23881123
Ding, W X; Lin, L; Duff, J R; Brower, D L
2014-11-01
Magnetic fluctuation-induced transport driven by global tearing modes has been measured by Faraday-effect polarimetry and interferometry (phase measurements) in the MST reversed field pinch. However, the role of small-scale broadband magnetic and density turbulence in transport remains unknown. In order to investigate broadband magnetic turbulence, we plan to upgrade the existing detector system by using planar-diode fundamental waveguide mixers optimized for high sensitivity. Initial tests indicate these mixers have ×10 sensitivity improvement compared to currently employed corner-cube Schottky-diode mixers and ×5 lower noise. Compact mixer design will allow us to resolve the wavenumbers up to k ∼ 1-2 cm(-1) for beam width w = 1.5 cm and 15 cm(-1) for beam width w = 2 mm. The system can also be used to measure the scattered signal (amplitude measurement) induced by both plasma density and magnetic fluctuations.
NASA Astrophysics Data System (ADS)
Aoki, Hirooki; Aoki, Hiroichi; Nakajima, Masato
Measurement of biological information appears to be an effective method to obtain an understanding of health conditions measures to maintain and improve the health of elderly people. However, every conventional bioinstrumentation technique imposes a sense of restraint that results in aversion against measurements that would last over consecutive days. To solve this problem, we propose a system for monitoring the respiration of sleepers, and it uses a fiber grating vision sensor, which is a type of optical range finder, to achieve non-contact and unrestrained monitoring. The signals obtained by the system include the respiration rate, shifts of the ventilation, and the body movement interval of the sleeper. The information enables to investigate the stability of the sleeper throughout the night. We examined the measuring accuracy, validity, and effectiveness of our proposed system. And all-night monitoring performed at elderly care facility revealed that respiratory disturbances during sleep occurred in many of the residents and that sleep apnea is a common syndrome, especially among residents who have senile dementia or have had a stroke. We were able to carry out the all-night monitoring with this system for a total of about 370 times, according to our schedule, without experiencing any failure, accident, or interruption. Our proposed system is highly effective for monitoring elderly dementia patients who are likely to become uncooperative during measurement with existing monitoring methods that use certain amounts of restraint.
Service collaboration and hospital cost performance: direct and moderating effects.
Proenca, E Jose; Rosko, Michael D; Dismuke, Clara E
2005-12-01
Growing reliance on service provision through systems and networks creates the need to better understand the nature of the relationship between service collaboration and hospital performance and the conditions that affect this relationship. We examine 1) the effects of service provision through health systems and health networks on hospital cost performance and 2) the moderating effects of market conditions and service differentiation on the collaboration-cost relationship. We used moderated regression analysis to test the direct and moderating effects. Data on 1368 private hospitals came from the 1998 AHA Annual Survey, Medicare Cost Reports, and Solucient. Service collaboration was measured as the proportion of hospital services provided at the system level and at the network level. Market conditions were measured by the levels of managed care penetration and competition in the hospital's market. The proportion of hospital services provided at the system level had a negative relationship with hospital cost. The relationship was curvilinear for network use. Degree of managed care penetration moderated the relationship between network-based collaboration and hospital cost. The benefits of service collaboration through systems and networks, as measured by reduced cost, depend on degree of collaboration rather than mere membership. In loosely structured collaborations such as networks, costs reduce initially but increase later as the extent of collaboration increases. The effect of network-based collaboration is also tempered by managed care penetration. These effects are not seen in more tightly integrated forms such as systems.
Measuring Hydrogen Concentrations in Metals
NASA Technical Reports Server (NTRS)
Danford, M. D.
1985-01-01
Commercial corrosion-measurement system adapted to electrochemical determination of hydrogen concentrations in metals. New technique based on diffusion of hydrogen through foil specimen of metal. In sample holder, hydrogen produced on one side of foil, either by corrosion reaction or by cathodic current. Hydrogen diffused through foil removed on other side by constant anode potential, which leads to oxidation of hydrogen to water. Anode current is measure of concentration of hydrogen diffusing through foil. System used to study hydrogen uptake, hydrogen elimination by baking, effect of heat treatment, and effect of electroplating on high-strength steels.
Ellakwa, A; Elnajar, S; Littlefair, D; Sara, G
2018-05-03
The aim of the current study is to develop a novel method to investigate the accuracy of 3D scanners and digital articulation systems. An upper and a lower poured stone model were created by taking impression of fully dentate male (fifty years old) participant. Titanium spheres were added to the models to allow for an easily recognisable geometric shape for measurement after scanning and digital articulation. Measurements were obtained using a Coordinate Measuring Machine to record volumetric error, articulation error and clinical effect error. Three scanners were compared, including the Imetric 3D iScan d104i, Shining 3D AutoScan-DS100 and 3Shape D800, as well as their respective digital articulation software packages. Stoneglass Industries PDC digital articulation system was also applied to the Imetric scans for comparison with the CMM measurements. All the scans displayed low volumetric error (p⟩0.05), indicating that the scanners themselves had a minor contribution to the articulation and clinical effect errors. The PDC digital articulation system was found to deliver the lowest average errors, with good repeatability of results. The new measuring technique in the current study was able to assess the scanning and articulation accuracy of the four systems investigated. The PDC digital articulation system using Imetric scans was recommended as it displayed the lowest articulation error and clinical effect error with good repeatability. The low errors from the PDC system may have been due to its use of a 3D axis for alignment rather than the use of a best fit. Copyright© 2018 Dennis Barber Ltd.
DOT National Transportation Integrated Search
2016-11-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
DOT National Transportation Integrated Search
2018-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
DOT National Transportation Integrated Search
2017-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
DOT National Transportation Integrated Search
2015-01-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National : Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor : carrier interventions in terms...
DOT National Transportation Integrated Search
2017-04-01
The Federal Motor Carrier Safety Administration (FMCSA), in cooperation with the John A. Volpe National Transportation Systems Center (Volpe), has developed a quantitative model to measure the effectiveness of motor carrier interventions in terms of ...
Emission measurements for a lean premixed propane/air system at pressures up to 30 atmospheres
NASA Technical Reports Server (NTRS)
Roffe, G.; Venkataramani, K. S.
1978-01-01
The emissions of a lean premixed system of propane/air were measured in a flametube apparatus. Tests were conducted at inlet temperatures of 600K and 800K and pressures of 10 atm and 30 atm over a range of equivalence ratios. The data obtained were combined with previous data taken in the same apparatus to correlate nitrogen oxide emissions with operating conditions. Sampling probe design was found to have a pronounced effect on measured CO levels but did not influence measurements. The most effective probe tested was one which combined thermal and pressure quenching of the gas sample.
NASA Astrophysics Data System (ADS)
Cournane, S.; Browne, J. E.; Fagan, A. J.
2012-06-01
A new generation of ultrasound transient elastography (TE) systems have emerged which exploit the well-known correlation between the liver's pathological and mechanical properties through measurements of the Young's elastic modulus; however, little work has been carried out to examine the effect that fatty deposits may have on the TE measurement accuracy. An investigation was carried out on the effects on the measurement accuracy of a TE ultrasound system, the Fibroscan®, caused by overlaying fat layers of varying thickness on healthy liver-mimicking phantoms, simulating in vivo conditions for obese patients. Furthermore, a steatosis effect similar to that in non-alcoholic fatty liver disease (NAFLD) and alcoholic liver disease (ALD) was simulated to investigate its effect on the TE system. A range of novel elastography fat-mimicking materials were developed using 6-10 wt% poly(vinyl alcohol) cryogel capable of achieving a range of acoustic velocities (1482-1530 m s-1) and attenuation coefficients (0.4-1 dB MHz-1 cm-1) for simulating different liver states. Laboratory-based acoustic velocities and attenuation coefficients were measured while the Young's modulus was established through a gold standard compression testing method. A significant variation of the Young's elastic modulus was measured in healthy phantoms with overlaying fat layers of thicknesses exceeding 45 mm, impinging on the scanners region of interest, overestimating the compression tested values by up to 11 kPa in some cases. Furthermore, Fibroscan® measurements of the steatosis phantoms showed a consistent overestimation (˜54%), which strongly suggests that the speed of sound mismatch between that of liver tissue and that assumed by the scanner is responsible for the high clinical cut-offs established in the case of ALD and NAFLD.
Optoelectronic instrumentation enhancement using data mining feedback for a 3D measurement system
NASA Astrophysics Data System (ADS)
Flores-Fuentes, Wendy; Sergiyenko, Oleg; Gonzalez-Navarro, Félix F.; Rivas-López, Moisés; Hernandez-Balbuena, Daniel; Rodríguez-Quiñonez, Julio C.; Tyrsa, Vera; Lindner, Lars
2016-12-01
3D measurement by a cyber-physical system based on optoelectronic scanning instrumentation has been enhanced by outliers and regression data mining feedback. The prototype has applications in (1) industrial manufacturing systems that include: robotic machinery, embedded vision, and motion control, (2) health care systems for measurement scanning, and (3) infrastructure by providing structural health monitoring. This paper presents new research performed in data processing of a 3D measurement vision sensing database. Outliers from multivariate data have been detected and removal to improve artificial intelligence regression algorithm results. Physical measurement error regression data has been used for 3D measurements error correction. Concluding, that the joint of physical phenomena, measurement and computation is an effectiveness action for feedback loops in the control of industrial, medical and civil tasks.
NASA Astrophysics Data System (ADS)
Zemánek, Ivan; Havlíček, Václav
2006-09-01
A new universal control and measuring system for classic and amorphous soft magnetic materials single/on-line strip testing has been developed at the Czech Technical University in Prague. The measuring system allows to measure magnetization characteristic and specific power losses of different tested materials (strips) at AC magnetization of arbitrary magnetic flux density waveform at wide range of frequencies 20 Hz-20 kHz. The measuring system can be used for both single strip testing in laboratories and on-line strip testing during the production process. The measuring system is controlled by two-stage master-slave control system consisting of the external PC (master) completed by three special A/D measuring plug-in boards, and local executing control unit (slave) with one-chip microprocessor 8051, connected with PC by the RS232 serial line. The "user friendly" powerful control software implemented on the PC and the effective program code for the microprocessor give possibility for full automatic measurement with high measuring power and high measuring accuracy.
Richardson, Jeff; Iezzi, Angelo; Khan, Munir A
2015-08-01
Health state utilities measured by the major multi-attribute utility instruments differ. Understanding the reasons for this is important for the choice of instrument and for research designed to reconcile these differences. This paper investigates these reasons by explaining pairwise differences between utilities derived from six multi-attribute utility instruments in terms of (1) their implicit measurement scales; (2) the structure of their descriptive systems; and (3) 'micro-utility effects', scale-adjusted differences attributable to their utility formula. The EQ-5D-5L, SF-6D, HUI 3, 15D and AQoL-8D were administered to 8,019 individuals. Utilities and unweighted values were calculated using each instrument. Scale effects were determined by the linear relationship between utilities, the effect of the descriptive system by comparison of scale-adjusted values and 'micro-utility effects' by the unexplained difference between utilities and values. Overall, 66 % of the differences between utilities was attributable to the descriptive systems, 30.3 % to scale effects and 3.7 % to micro-utility effects. Results imply that the revision of utility algorithms will not reconcile differences between instruments. The dominating importance of the descriptive system highlights the need for researchers to select the instrument most capable of describing the health states relevant for a study. Reconciliation of inconsistent utilities produced by different instruments must focus primarily upon the content of the descriptive system. Utility weights primarily determine the measurement scale. Other differences, attributable to utility formula, are comparatively unimportant.
Measurement systems and indices of miners' exposure to radon daughter products in the air of mines.
Domański, T
1990-01-01
This paper presents the classification of measurement systems that may be used for the assessment of miners' exposure to radiation in mines. The following systems were described and characterized as the Air Sampling System (ASS), the Environmental Control System (ECS), the Individual Dosimetry System (IDS), the Stream Monitoring System (SMS) and the Exhaust Monitoring System (EMS). The indices for evaluation of miners' working environments, or for assessment of individual or collective miners' exposure, were selected and determined. These are: average expected concentration (CAE), average observed concentration (CAO), average expected rate of exposure cumulation rate (EEXP), average observed exposure cumulation rate (EOBS), average effective exposure cumulation rate (EEFF). Mathematical formulae for determining all these indicators, according to the type of measurement system used in particular mines, are presented. The reliability of assessment of miners' exposure in particular measurement systems, as well as the role of the possible reference system, are discussed.
ERIC Educational Resources Information Center
Chase, Justin P.; Yan, Zheng
2017-01-01
The ability to effective learn, process, and retain new information is critical to the success of any student. Since mathematics are becoming increasingly more important in our educational systems, it is imperative that we devise an efficient system to measure these types of information recall. "Assessing and Measuring Statistics Cognition in…
ERIC Educational Resources Information Center
Willis, Lynne
2010-01-01
Managing change in education is a complex process, but to do so under the pressure of a punishment-based measurement system (Fullan, 2008) makes sustainable and meaningful change increasingly difficult. Systems which produce high stakes accountability measures, which bring with it sanctions that create a greater sense of distrust, demoralization…
A Fiber-Optic Current Sensor for Lightning Measurement Applications
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.
2015-01-01
An optical-fiber sensor based on Faraday Effect is developed for measuring total lightning electric current. It has many unique capabilities not possible with traditional current sensors. Designed for aircraft installation, the sensor is lightweight, non-conducting, structure-conforming, and is immune to electromagnetic interference, hysteresis and saturation. It can also be used on windmills, lightning towers, and can help validate lightning detection network measurements. Faraday Effect causes light polarization to rotate when the fiber is exposed to a magnetic field in the direction of light propagation. Thus, the magnetic field strength can be determined from the light polarization change. By forming closed fiber loops and applying Ampere's law, measuring the total light rotation yields the total current enclosed. The broadband, dual-detector, reflective polarimetric scheme allows measurement of both DC component and AC waveforms with about 60 dB dynamic range. Three sensor systems were built with different sensitivities from different laser wavelengths. Operating at 850nm, the first system uses twisted single-mode fiber and has a 150 A - 150 KA range. The second system operates at 1550nm, uses spun polarization maintaining fiber, and can measure 400 A - 400 KA. Both systems were validated with rocket-triggered lightning measurements and achieved excellent results when compared to a resistive shunt. The third system operates at 1310nm, uses spun polarization maintaining fiber, and can measure approximately 300 A - 300 KA. High current measurements up to 200 KA were demonstrated at a commercial lightning test facility. The system was recently installed on an aircraft and flown near icing weather conditions.
A fiber-optic current sensor for lightning measurement applications
NASA Astrophysics Data System (ADS)
Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.
2015-05-01
An optical-fiber sensor based on Faraday Effect is developed for measuring total lightning electric current. It has many unique capabilities not possible with traditional current sensors. Designed for aircraft installation, the sensor is lightweight, non-conducting, structure-conforming, and is immune to electromagnetic interference, hysteresis and saturation. It can also be used on windmills, lightning towers, and can help validate lightning detection network measurements. Faraday Effect causes light polarization to rotate when the fiber is exposed to a magnetic field in the direction of light propagation. Thus, the magnetic field strength can be determined from the light polarization change. By forming closed fiber loops and applying Ampere's law, measuring the total light rotation yields the total current enclosed. The broadband, dual-detector, reflective polarimetric scheme allows measurement of both DC component and AC waveforms with about 60 dB dynamic range. Three sensor systems were built with different sensitivities from different laser wavelengths. Operating at 850nm, the first system uses twisted single-mode fiber and has a 150 A - 150 KA range. The second system operates at 1550nm, uses spun polarization maintaining fiber, and can measure 400 A - 400 KA. Both systems were validated with rocket-triggered lightning measurements and achieved excellent results when compared to a resistive shunt. The third system operates at 1310nm, uses spun polarization maintaining fiber, and can measure approximately 300 A - 300 KA. High current measurements up to 200 KA were demonstrated at a commercial lightning test facility. The system was recently installed on an aircraft and flown near icing weather conditions.
Defining pharmaceutical systems strengthening: concepts to enable measurement
Hafner, Tamara; Lee, David; Aboagye-Nyame, Francis
2017-01-01
Abstract Pharmaceutical products are indispensable for improving health outcomes. An extensive body of work on access to and use of medicines has resulted in an assortment of tools measuring various elements of pharmaceutical systems. Until now however, there has been little attempt to conceptualize a pharmaceutical system as an entity and define its strengthening in a way that allows for measuring systems strengthening. The narrow focus of available tools limits their value in ascertaining which interventions result in stronger, more resilient systems. We sought to address this shortcoming by revisiting the current definitions, frameworks and assessment tools related to pharmaceutical systems. We conducted a comprehensive literature review and consulted with select pharmaceutical experts. On the basis of our review, we propose that a pharmaceutical system consists of all structures, people, resources, processes, and their interactions within the broader health system that aim to ensure equitable and timely access to safe, effective, quality pharmaceutical products and related services that promote their appropriate and cost-effective use to improve health outcomes. We further propose that pharmaceutical systems strengthening is the process of identifying and implementing strategies and actions that achieve coordinated and sustainable improvements in the critical components of a pharmaceutical system to make it more responsive and resilient and to enhance its performance for achieving better health outcomes. Finally, we established that, in addition to system performance and resilience, seven components of the pharmaceutical system are critical for measuring pharmaceutical systems strengthening: pharmaceutical products and related services; policy, laws and governance; regulatory systems; innovation, research and development, manufacturing, and trade; financing; human resources; and information. This work adds clarity to the concept of pharmaceutical systems and their strengthening by proposing holistic definitions on the basis of systems thinking. It provides a practical starting point for measuring the progress of pharmaceutical systems strengthening. PMID:28025324
Simulation of mass storage systems operating in a large data processing facility
NASA Technical Reports Server (NTRS)
Holmes, R.
1972-01-01
A mass storage simulation program was written to aid system designers in the design of a data processing facility. It acts as a tool for measuring the overall effect on the facility of on-line mass storage systems, and it provides the means of measuring and comparing the performance of competing mass storage systems. The performance of the simulation program is demonstrated.
NASA Astrophysics Data System (ADS)
Shrikanth, V.; Bobji, M. S.
2014-10-01
Resonant sensors and crystal oscillators for mass detection need to be excited at very high natural frequencies (MHz). Use of such systems to measure mass of biological materials affects the accuracy of mass measurement due to their viscous and/or viscoelastic properties. The measurement limitation of such sensor system is the difficulty in accounting for the "missing mass" of the biological specimen in question. A sensor system has been developed in this work, to be operated in the stiffness controlled region at very low frequencies as compared to its fundamental natural frequency. The resulting reduction in the sensitivity due to non-resonant mode of operation of this sensor is compensated by the high resolution of the sensor. The mass of different aged drosophila melanogaster (fruit fly) is measured. The difference in its mass measurement during resonant mode of operation is also presented. That, viscosity effects do not affect the working of this non-resonant mass sensor is clearly established by direct comparison.
Navigation systems. [for interplanetary flight
NASA Technical Reports Server (NTRS)
Jordan, J. F.
1985-01-01
The elements of the measurement and communications network comprising the global deep space navigation system (DSN) for NASA missions are described. Among the measurement systems discussed are: VLBI, two-way Doppler and range measurements, and optical measurements carried out on board the spacecraft. Processing of navigation measurement is carried out using two modules: an N-body numerical integration of the trajectory (and state transition partial derivatives) based on pre-guessed initial conditions; and partial derivatives of simulated observables corresponding to each actual observation. Calculations of velocity correction parameters is performed by precise modelling of all physical phenomena influencing the observational measurements, including: planetary motions; tracking station locations, gravity field structure, and transmission media effects. Some of the contributions to earth-relative orbit estimate errors for the Doppler/range system on board Voyager are discussed in detail. A line drawing of the DSN navigation system is provided.
Results of the first complete static calibration of the RSRA rotor-load-measurement system
NASA Technical Reports Server (NTRS)
Acree, C. W., Jr.
1984-01-01
The compound Rotor System Research Aircraft (RSRA) is designed to make high-accuracy, simultaneous measurements of all rotor forces and moments in flight. Physical calibration of the rotor force- and moment-measurement system when installed in the aircraft is required to account for known errors and to ensure that measurement-system accuracy is traceable to the National Bureau of Standards. The first static calibration and associated analysis have been completed with good results. Hysteresis was a potential cause of static calibration errors, but was found to be negligible in flight compared to full-scale loads, and analytical methods have been devised to eliminate hysteresis effects on calibration data. Flight tests confirmed that the calibrated rotor-load-measurement system performs as expected in flight and that it can dependably make direct measurements of fuselage vertical drag in hover.
The unbalanced signal measuring of automotive brake drum
NASA Astrophysics Data System (ADS)
Wang, Xiao-Dong; Ye, Sheng-Hua; Zhang, Bang-Cheng
2005-04-01
For the purpose of the research and development of automatic balancing system by mass removing, the dissertation deals with the measuring method of the unbalance signal, the design the automatic balance equipment and the software. This paper emphases the testing system of the balancer of automotive brake drum. The paper designs the band-pass filter product with favorable automatic follow of electronic product, and with favorable automatic follow capability, filtration effect and stability. The system of automatic balancing system by mass removing based on virtual instrument is designed in this paper. A lab system has been constructed. The results of contrast experiments indicate the notable effect of 1-plane automatic balance and the high precision of dynamic balance, and demonstrate the application value of the system.
Optimization of dynamic envelope measurement system for high speed train based on monocular vision
NASA Astrophysics Data System (ADS)
Wu, Bin; Liu, Changjie; Fu, Luhua; Wang, Zhong
2018-01-01
The definition of dynamic envelope curve is the maximum limit outline caused by various adverse effects during the running process of the train. It is an important base of making railway boundaries. At present, the measurement work of dynamic envelope curve of high-speed vehicle is mainly achieved by the way of binocular vision. There are some problems of the present measuring system like poor portability, complicated process and high cost. A new measurement system based on the monocular vision measurement theory and the analysis on the test environment is designed and the measurement system parameters, the calibration of camera with wide field of view, the calibration of the laser plane are designed and optimized in this paper. The accuracy has been verified to be up to 2mm by repeated tests and experimental data analysis. The feasibility and the adaptability of the measurement system is validated. There are some advantages of the system like lower cost, a simpler measurement and data processing process, more reliable data. And the system needs no matching algorithm.
NASA Astrophysics Data System (ADS)
Ko, Heasin; Choi, Byung-Seok; Choe, Joong-Seon; Youn, Chun Ju
2018-01-01
Even though unconditional security of B92 quantum key distribution (QKD) system is based on the assumption of perfect positive-operator-valued measures, practical B92 systems only utilize two projective measurements. Unfortunately, such implementation may degrade the security of the B92 QKD system due to Eve's potential attack exploiting the imperfection of system. In this paper, we propose an advanced attack strategy with an unambiguous state discrimination (USD) measurement which makes practical B92 QKD systems insecure even under a lossless channel. In addition, we propose an effective countermeasure against the advanced USD attack model by monitoring double-click events. We further address a fundamental approach to make the B92 QKD system tolerable to attack strategies with USD measurements using a multi-qubit scheme.
A Vision-Based Dynamic Rotational Angle Measurement System for Large Civil Structures
Lee, Jong-Jae; Ho, Hoai-Nam; Lee, Jong-Han
2012-01-01
In this paper, we propose a vision-based rotational angle measurement system for large-scale civil structures. Despite the fact that during the last decade several rotation angle measurement systems were introduced, they however often required complex and expensive equipment. Therefore, alternative effective solutions with high resolution are in great demand. The proposed system consists of commercial PCs, commercial camcorders, low-cost frame grabbers, and a wireless LAN router. The calculation of rotation angle is obtained by using image processing techniques with pre-measured calibration parameters. Several laboratory tests were conducted to verify the performance of the proposed system. Compared with the commercial rotation angle measurement, the results of the system showed very good agreement with an error of less than 1.0% in all test cases. Furthermore, several tests were conducted on the five-story modal testing tower with a hybrid mass damper to experimentally verify the feasibility of the proposed system. PMID:22969348
A vision-based dynamic rotational angle measurement system for large civil structures.
Lee, Jong-Jae; Ho, Hoai-Nam; Lee, Jong-Han
2012-01-01
In this paper, we propose a vision-based rotational angle measurement system for large-scale civil structures. Despite the fact that during the last decade several rotation angle measurement systems were introduced, they however often required complex and expensive equipment. Therefore, alternative effective solutions with high resolution are in great demand. The proposed system consists of commercial PCs, commercial camcorders, low-cost frame grabbers, and a wireless LAN router. The calculation of rotation angle is obtained by using image processing techniques with pre-measured calibration parameters. Several laboratory tests were conducted to verify the performance of the proposed system. Compared with the commercial rotation angle measurement, the results of the system showed very good agreement with an error of less than 1.0% in all test cases. Furthermore, several tests were conducted on the five-story modal testing tower with a hybrid mass damper to experimentally verify the feasibility of the proposed system.
Optical 3D-coordinate measuring system using structured light
NASA Astrophysics Data System (ADS)
Schreiber, Wolfgang; Notni, Gunther; Kuehmstedt, Peter; Gerber, Joerg; Kowarschik, Richard M.
1996-09-01
The paper is aimed at the description of an optical shape measuring technique based on a consistent principle using fringe projection technique. We demonstrate a real 3D- coordinate measuring system where the sale of coordinates is given only by the illumination-structures. This method has the advantages that the aberration of the observing system and the depth-dependent imaging scale have no influence on the measuring accuracy and, moreover, the measurements are independent of the position of the camera with respect to the object under test. Furthermore, it is shown that the influence of specular effects of the surface on the measuring result can be eliminated. Moreover, we developed a very simple algorithm to calibrate the measuring system. The measuring examples show that a measuring accuracy of 10-4 (i.e. 10 micrometers ) within an object volume of 100 X 100 X 70 mm3 is achievable. Furthermore, it is demonstrated that the set of coordinate values can be processed in CNC- and CAD-systems.
Laser confocal measurement system for curvature radius of lenses based on grating ruler
NASA Astrophysics Data System (ADS)
Tian, Jiwei; Wang, Yun; Zhou, Nan; Zhao, Weirui; Zhao, Weiqian
2015-02-01
In the modern optical measurement field, the radius of curvature (ROC) is one of the fundamental parameters of optical lens. Its measurement accuracy directly affects the other optical parameters, such as focal length, aberration and so on, which significantly affect the overall performance of the optical system. To meet the demand of measurement instruments for radius of curvature (ROC) with high accuracy in the market, we develop a laser confocal radius measurement system with grating ruler. The system uses the peak point of the confocal intensity curve to precisely identify the cat-eye and confocal positions and then measure the distance between these two positions by using the grating ruler, thereby achieving the high-precision measurement for the ROC. The system has advantages of high focusing sensitivity and anti-environment disturbance ability. And the preliminary theoretical analysis and experiments show that the measuring repeatability can be up to 0.8 um, which can provide an effective way for the accurate measurement of ROC.
Optical fiber-based system for continuous measurement of in-bore projectile velocity.
Wang, Guohua; Sun, Jinglin; Li, Qiang
2014-08-01
This paper reports the design of an optical fiber-based velocity measurement system and its application in measuring the in-bore projectile velocity. The measurement principle of the implemented system is based on Doppler effect and heterodyne detection technique. The analysis of the velocity measurement principle deduces the relationship between the projectile velocity and the instantaneous frequency (IF) of the optical fiber-based system output signal. To extract the IF of the fast-changing signal carrying the velocity information, an IF extraction algorithm based on the continuous wavelet transforms is detailed. Besides, the performance of the algorithm is analyzed by performing corresponding simulation. At last, an in-bore projectile velocity measurement experiment with a sniper rifle having a 720 m/s muzzle velocity is performed to verify the feasibility of the optical fiber-based velocity measurement system. Experiment results show that the measured muzzle velocity is 718.61 m/s, and the relative uncertainty of the measured muzzle velocity is approximately 0.021%.
Optical fiber-based system for continuous measurement of in-bore projectile velocity
NASA Astrophysics Data System (ADS)
Wang, Guohua; Sun, Jinglin; Li, Qiang
2014-08-01
This paper reports the design of an optical fiber-based velocity measurement system and its application in measuring the in-bore projectile velocity. The measurement principle of the implemented system is based on Doppler effect and heterodyne detection technique. The analysis of the velocity measurement principle deduces the relationship between the projectile velocity and the instantaneous frequency (IF) of the optical fiber-based system output signal. To extract the IF of the fast-changing signal carrying the velocity information, an IF extraction algorithm based on the continuous wavelet transforms is detailed. Besides, the performance of the algorithm is analyzed by performing corresponding simulation. At last, an in-bore projectile velocity measurement experiment with a sniper rifle having a 720 m/s muzzle velocity is performed to verify the feasibility of the optical fiber-based velocity measurement system. Experiment results show that the measured muzzle velocity is 718.61 m/s, and the relative uncertainty of the measured muzzle velocity is approximately 0.021%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tusheva, P.; Schaefer, F.; Kliem, S.
2012-07-01
The reactor safety issues are of primary importance for preserving the health of the population and ensuring no release of radioactivity and fission products into the environment. A part of the nuclear research focuses on improvement of the safety of existing nuclear power plants. Studies, research and efforts are a continuing process at improving the safety and reliability of existing and newly developed nuclear power plants at prevention of a core melt accident. Station blackout (loss of AC power supply) is one of the dominant accidents taken into consideration at performing accident analysis. In case of multiple failures of safetymore » systems it leads to a severe accident. To prevent an accident to turn into a severe one or to mitigate the consequences, accident management measures must be performed. The present paper outlines possibilities for application and optimization of accident management measures following a station blackout accident. Assessed is the behaviour of the nuclear power plant during a station blackout accident without accident management measures and with application of primary/secondary side oriented accident management measures. Discussed are the possibilities for operators ' intervention and the influence of the performed accident management measures on the course of the accident. Special attention has been paid to the effectiveness of the passive feeding and physical phenomena having an influence on the system behaviour. The performed simulations show that the effectiveness of the secondary side feeding procedure can be limited due to an early evaporation or flashing effects in the feed water system. The analyzed cases show that the effectiveness of the accident management measures strongly depends on the initiation criteria applied for depressurization of the reactor coolant system. (authors)« less
NASA Astrophysics Data System (ADS)
Hwang, Ui-Jung; Shin, Dongho; Lee, Se Byeong; Lim, Young Kyung; Jeong, Jong Hwi; Kim, Hak Soo; Kim, Ki Hwan
2018-05-01
To apply a scintillating fiber dosimetry system to measure the range of a proton therapy beam, a new method was proposed to correct for the quenching effect on measuring an spread out Bragg peak (SOBP) proton beam whose range is modulated by a range modulator wheel. The scintillating fiber dosimetry system was composed of a plastic scintillating fiber (BCF-12), optical fiber (SH 2001), photo multiplier tube (H7546), and data acquisition system (PXI6221 and SCC68). The proton beam was generated by a cyclotron (Proteus-235) in the National Cancer Center in Korea. It operated in the double-scattering mode and the spread out of the Bragg peak was achieved by a spinning range modulation wheel. Bragg peak beams and SOBP beams of various ranges were measured, corrected, and compared to the ion chamber data. For the Bragg peak beam, quenching equation was used to correct the quenching effect. On the proposed process of correcting SOBP beams, the measured data using a scintillating fiber were separated by the Bragg peaks that the SOBP beam contained, and then recomposed again to reconstruct an SOBP after correcting for each Bragg peak. The measured depth-dose curve for the single Bragg peak beam was well corrected by using a simple quenching equation. Correction for SOBP beam was conducted with a newly proposed method. The corrected SOBP signal was in accordance with the results measured with an ion chamber. We propose a new method to correct for the SOBP beam from the quenching effect in a scintillating fiber dosimetry system. This method can be applied to other scintillator dosimetry for radiation beams in which the quenching effect is shown in the scintillator.
DOT National Transportation Integrated Search
2014-01-24
The Carrier Safety Measurement System (CSMS) is the Federal Motor Carrier Safety Administrations (FMCSA's) workload prioritization tool. This tool is used to identify carriers with potential safety issues so that they are subject to interventions ...
DOT National Transportation Integrated Search
1966-05-01
A system for virtually continuous measurement of both systolic and diatolic blood pressures without recourse to direct arterial puncture has been effected by the modification of already existing standard equipment. This system entails the measurement...
Measuring School Performance To Improve Student Achievement and To Reward Effective Programs.
ERIC Educational Resources Information Center
Heistad, Dave; Spicuzza, Rick
This paper describes the method that the Minneapolis Public School system (MPS), Minnesota, uses to measure school and student performance. MPS uses a multifaceted system that both captures and accounts for the complexity of a large urban school district. The system incorporates: (1) a hybrid model of critical indicators that report on level of…
ERIC Educational Resources Information Center
Robertson, Rachel
2011-01-01
Among quality measurement systems, there is no clear description of how administrators are expected to move through the process. This is not necessarily a fault of the systems; it is not their intention to script a program's process. Yes, there are many tasks that are logically the administrator's responsibility--important things that must get…
Procurement performance measurement system in the health care industry.
Kumar, Arun; Ozdamar, Linet; Ng, Chai Peng
2005-01-01
The rising operating cost of providing healthcare is of concern to health care providers. As such, measurement of procurement performance will enable competitive advantage and provide a framework for continuous improvement. The objective of this paper is to develop a procurement performance measurement system. The paper reviews the existing literature in procurement performance measurement to identify the key areas of purchasing performance. By studying the three components in the supply chain collectively with the resources, procedures and output, a model is been developed. Additionally, a balanced scorecard is proposed by establishing a set of generic measures and six perspectives. A case study conducted at the Singapore Hospital applies the conceptual model to describe the purchasing department and the activities within and outside the department. The results indicate that the material management department has already made a good start in measuring the procurement process through the implementation of the balanced scorecard. There are many data that are collected but not properly collated and utilized. Areas lacking measurement include cycle time of delivery, order processing time, effectiveness, efficiency and reliability. Though a lot of hard work was involved, the advantages of establishing a measurement system outweigh the costs and efforts involved in its implementation. Results of balanced scorecard measurements provide decision-makers with critical information on efficiency and effectiveness of the purchasing department's work. The measurement model developed could be used for any hospital procurement system.
[A novel biologic electricity signal measurement based on neuron chip].
Lei, Yinsheng; Wang, Mingshi; Sun, Tongjing; Zhu, Qiang; Qin, Ran
2006-06-01
Neuron chip is a multiprocessor with three pipeline CPU; its communication protocol and control processor are integrated in effect to carry out the function of communication, control, attemper, I/O, etc. A novel biologic electronic signal measurement network system is composed of intelligent measurement nodes with neuron chip at the core. In this study, the electronic signals such as ECG, EEG, EMG and BOS can be synthetically measured by those intelligent nodes, and some valuable diagnostic messages are found. Wavelet transform is employed in this system to analyze various biologic electronic signals due to its strong time-frequency ability of decomposing signal local character. Better effect is gained. This paper introduces the hardware structure of network and intelligent measurement node, the measurement theory and the signal figure of data acquisition and processing.
NASA Astrophysics Data System (ADS)
Deng, Zhengping; Li, Shuanggao; Huang, Xiang
2018-06-01
In the assembly process of large-size aerospace products, the leveling and horizontal alignment of large components are essential prior to the installation of an inertial navigation system (INS) and the final quality inspection. In general, the inherent coordinate systems of large-scale coordinate measuring devices are not coincident with the geodetic horizontal system, and a dual-axis compensation system is commonly required for the measurement of difference in heights. These compensation systems are expensive and dedicated designs for different devices at present. Considering that a large-size assembly site usually needs more than one measuring device, a compensation approach which is versatile for different devices would be a more convenient and economic choice for manufacturers. In this paper, a flexible and cost-effective compensation method is proposed. Firstly, an auxiliary measuring device called a versatile compensation fixture (VCF) is designed, which mainly comprises reference points for coordinate transformation and a dual-axis inclinometer, and a kind of network tighten points (NTPs) are introduced and temporarily deployed in the large measuring space to further reduce transformation error. Secondly, the measuring principle of height difference is studied, based on coordinate transformation theory and trigonometry while considering the effects of earth curvature, and the coordinate transformation parameters are derived by least squares adjustment. Thirdly, the analytical solution of leveling uncertainty is analyzed, based on which the key parameters of the VCF and the proper deployment of NTPs are determined according to the leveling accuracy requirement. Furthermore, the proposed method is practically applied to the assembly of a large helicopter by developing an automatic leveling and alignment system. By measuring four NTPs, the leveling uncertainty (2σ) is reduced by 29.4% to about 0.12 mm, compared with that without NTPs.
A cost-effective measurement-device-independent quantum key distribution system for quantum networks
NASA Astrophysics Data System (ADS)
Valivarthi, Raju; Zhou, Qiang; John, Caleb; Marsili, Francesco; Verma, Varun B.; Shaw, Matthew D.; Nam, Sae Woo; Oblak, Daniel; Tittel, Wolfgang
2017-12-01
We experimentally realize a measurement-device-independent quantum key distribution (MDI-QKD) system. It is based on cost-effective and commercially available hardware such as distributed feedback lasers and field-programmable gate arrays that enable time-bin qubit preparation and time-tagging, and active feedback systems that allow for compensation of time-varying properties of photons after transmission through deployed fiber. We examine the performance of our system, and conclude that its design does not compromise performance. Our demonstration paves the way for MDI-QKD-based quantum networks in star-type topology that extend over more than 100 km distance.
Advanced Active-Magnetic-Bearing Thrust-Measurement System
NASA Technical Reports Server (NTRS)
Imlach, Joseph; Kasarda, Mary; Blumber, Eric
2008-01-01
An advanced thrust-measurement system utilizes active magnetic bearings to both (1) levitate a floating frame in all six degrees of freedom and (2) measure the levitation forces between the floating frame and a grounded frame. This system was developed for original use in measuring the thrust exerted by a rocket engine mounted on the floating frame, but can just as well be used in other force-measurement applications. This system offers several advantages over prior thrust-measurement systems based on mechanical support by flexures and/or load cells: The system includes multiple active magnetic bearings for each degree of freedom, so that by selective use of one, some, or all of these bearings, it is possible to test a given article over a wide force range in the same fixture, eliminating the need to transfer the article to different test fixtures to obtain the benefit of full-scale accuracy of different force-measurement devices for different force ranges. Like other active magnetic bearings, the active magnetic bearings of this system include closed-loop control subsystems, through which the stiffness and damping characteristics of the magnetic bearings can be modified electronically. The design of the system minimizes or eliminates cross-axis force-measurement errors. The active magnetic bearings are configured to provide support against movement along all three orthogonal Cartesian axes, and such that the support along a given axis does not produce force along any other axis. Moreover, by eliminating the need for such mechanical connections as flexures used in prior thrust-measurement systems, magnetic levitation of the floating frame eliminates what would otherwise be major sources of cross-axis forces and the associated measurement errors. Overall, relative to prior mechanical-support thrust-measurement systems, this system offers greater versatility for adaptation to a variety of test conditions and requirements. The basic idea of most prior active-magnetic-bearing force-measurement systems is to calculate levitation forces on the basis of simple proportionalities between changes in those forces and changes in feedback-controlled currents applied to levitating electromagnetic coils. In the prior systems, the effects of gap lengths on fringing magnetic fields and the concomitant effects on magnetic forces were neglected. In the present system, the control subsystems of the active magnetic bearings are coupled with a computer-based automatic calibration system running special-purpose software wherein gap-length-dependent fringing factors are applied to current and magnetic-flux-based force equations and combined with a multipoint calibration method to obtain greater accuracy.
STI: An objective measure for the performance of voice communication systems
NASA Astrophysics Data System (ADS)
Houtgast, T.; Steeneken, H. J. M.
1981-06-01
A measuring device was developed for determining the quality of speech communication systems. It comprises two parts, a signal source which replaces the talker, producing an artificial speech-like signal, and an analysis part which replaces the listener, by which the signal at the receiving end of the system under test is evaluated. Each single measurement results in an index (ranging from 0-100%) which indicates the effect of that communication system on speech intelligibility. The index is called STI (Speech Transmission Index). A careful design of the characteristics of the test signal and of the type of signal analysis makes the present approach widely applicable. It was verified experimentally that a given STI implies a given effect on speech intelligibility, irrespective of the nature of the actual disturbance (noise interference, band-pass limiting, peak clipping, etc.).
Small Total Dose Measurement System for SOHLA-1 and SDS-1
NASA Astrophysics Data System (ADS)
Kimoto, Yugo; Satoh, Yohei; Tachihara, Hiroshi
The Japanese Aerospace Exploration Agency (JAXA) uses monitors on board satellites to measure and record in-flight data about ionization effects in space. A compact, total-dose measurement system for small satellites—Space-Oriented Higashiosaka Leading Association -1 (SOHLA-1) and Small Demonstration-Satellite -1 (SDS-1)—was developed based on a prior system for measuring total ionizing dose effects. Especially, the sensor for SDS-1 is much smaller than the sensor for SOHLA-1. The sensor for SDS-1 is 8 mm wide × 3 mm high × 19 mm long and weighs approximately 4 g with 500 mm with its wire harness. An 8-pin Lead less Chip Carrier (LCC) RADFET and temperature sensor are arranged on it. Seven sensors are mounted on some components inside the SDS-1. The sensor for SOHLA-1 is a 14-pin Dual Inline Package (DIP) type RADFET. The four sensors, which have RADFET on a printed board covered with an aluminum chassis, are mounted both inside and outside the satellite. This report presents small total dose measurement systems and ground irradiation test results for two small satellites.
Lai, Jin-Shei; Hammel, Joy; Jerousek, Sara; Goldsmith, Arielle; Miskovic, Ana; Baum, Carolyn; Wong, Alex W; Dashner, Jessica; Heinemann, Allen W
2016-12-01
To develop a measure of perceived systems, services, and policies facilitators (see Chapter 5 of the International Classification of Functioning, Disability and Health) for people with neurologic disabilities and to evaluate the effect of perceived systems, services, and policies facilitators on health-related quality of life. Qualitative approaches to develop and refine items. Confirmatory factor analysis including 1-factor confirmatory factor analysis and bifactor analysis to evaluate unidimensionality of items. Rasch analysis to identify misfitting items. Correlational and analysis of variance methods to evaluate construct validity. Community-dwelling individuals participated in telephone interviews or traveled to the academic medical centers where this research took place. Participants (N=571) had a diagnosis of spinal cord injury, stroke, or traumatic brain injury. They were 18 years or older and English speaking. Not applicable. An item bank to evaluate environmental access and support levels of services, systems, and policies for people with disabilities. We identified a general factor defined as "access and support levels of the services, systems, and policies at the level of community living" and 3 local factors defined as "health services," "community living," and "community resources." The systems, services, and policies measure correlated moderately with participation measures: Community Participation Indicators (CPI) - Involvement, CPI - Control over Participation, Quality of Life in Neurological Disorders - Ability to Participate, Quality of Life in Neurological Disorders - Satisfaction with Role Participation, Patient-Reported Outcomes Measurement Information System (PROMIS) Ability to Participate, PROMIS Satisfaction with Role Participation, and PROMIS Isolation. The measure of systems, services, and policies facilitators contains items pertaining to health services, community living, and community resources. Investigators and clinicians can measure perceptions of systems, services, and policies resources reliably with the items described here. Moderate relations between systems, services, and policies facilitators and PROMIS and CPI variables provide support for the measurement and theory of environmental effects on social functioning related to participation. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.
Saccadic eye movements analysis as a measure of drug effect on central nervous system function.
Tedeschi, G; Quattrone, A; Bonavita, V
1986-04-01
Peak velocity (PSV) and duration (SD) of horizontal saccadic eye movements are demonstrably under the control of specific brain stem structures. Experimental and clinical evidence suggest the existence of an immediate premotor system for saccade generation located in the paramedian pontine reticular formation (PPRF). Effects on saccadic eye movements have been studied in normal volunteers with barbiturates, benzodiazepines, amphetamine and ethanol. On two occasions computer analysis of PSV, SD, saccade reaction time (SRT) and saccade accuracy (SA) was carried out in comparison with more traditional methods of assessment of human psychomotor performance like choice reaction time (CRT) and critical flicker fusion threshold (CFFT). The computer system proved to be a highly sensitive and objective method for measuring drug effect on central nervous system (CNS) function. It allows almost continuous sampling of data and appears to be particularly suitable for studying rapidly changing drug effects on the CNS.
Zhang, Xu; Jin, Weiqi; Li, Jiakun; Wang, Xia; Li, Shuo
2017-04-01
Thermal imaging technology is an effective means of detecting hazardous gas leaks. Much attention has been paid to evaluation of the performance of gas leak infrared imaging detection systems due to several potential applications. The minimum resolvable temperature difference (MRTD) and the minimum detectable temperature difference (MDTD) are commonly used as the main indicators of thermal imaging system performance. This paper establishes a minimum detectable gas concentration (MDGC) performance evaluation model based on the definition and derivation of MDTD. We proposed the direct calculation and equivalent calculation method of MDGC based on the MDTD measurement system. We build an experimental MDGC measurement system, which indicates the MDGC model can describe the detection performance of a thermal imaging system to typical gases. The direct calculation, equivalent calculation, and direct measurement results are consistent. The MDGC and the minimum resolvable gas concentration (MRGC) model can effectively describe the performance of "detection" and "spatial detail resolution" of thermal imaging systems to gas leak, respectively, and constitute the main performance indicators of gas leak detection systems.
NASA Technical Reports Server (NTRS)
Kirschner, S. M.; Samii, M. V.; Broaddus, S. R.; Doll, C. E.
1988-01-01
The Preliminary Orbit Determination System (PODS) provides early orbit determination capability in the Trajectory Computation and Orbital Products System (TCOPS) for a Tracking and Data Relay Satellite System (TDRSS)-tracked spacecraft. PODS computes a set of orbit states from an a priori estimate and six tracking measurements, consisting of any combination of TDRSS range and Doppler tracking measurements. PODS uses the homotopy continuation method to solve a set of nonlinear equations, and it is particularly effective for the case when the a priori estimate is not well known. Since range and Doppler measurements produce multiple states in PODS, a screening technique selects the desired state. PODS is executed in the TCOPS environment and can directly access all operational data sets. At the completion of the preliminary orbit determination, the PODS-generated state, along with additional tracking measurements, can be directly input to the differential correction (DC) process to generate an improved state. To validate the computational and operational capabilities of PODS, tests were performed using simulated TDRSS tracking measurements for the Cosmic Background Explorer (COBE) satellite and using real TDRSS measurements for the Earth Radiation Budget Satellite (ERBS) and the Solar Mesosphere Explorer (SME) spacecraft. The effects of various measurement combinations, varying arc lengths, and levels of degradation of the a priori state vector on the PODS solutions were considered.
NASA Astrophysics Data System (ADS)
Sorteberg, Hilleborg K.
2010-05-01
In the hydropower industry, it is important to have precise information about snow deposits at all times, to allow for effective planning and optimal use of the water. In Norway, it is common to measure snow density using a manual method, i.e. the depth and weight of the snow is measured. In recent years, radar measurements have been taken from snowmobiles; however, few energy supply companies use this method operatively - it has mostly been used in connection with research projects. Agder Energi is the first Norwegian power producer in using radar tecnology from helicopter in monitoring mountain snow levels. Measurement accuracy is crucial when obtaining input data for snow reservoir estimates. Radar screening by helicopter makes remote areas more easily accessible and provides larger quantities of data than traditional ground level measurement methods. In order to draw up a snow survey system, it is assumed as a basis that the snow distribution is influenced by vegetation, climate and topography. In order to take these factors into consideration, a snow survey system for fields in high mountain areas has been designed in which the data collection is carried out by following the lines of a grid system. The lines of this grid system is placed in order to effectively capture the distribution of elevation, x-coordinates, y-coordinates, aspect, slope and curvature in the field. Variation in climatic conditions are also captured better when using a grid, and dominant weather patterns will largely be captured in this measurement system.
Development and Validation of a UAV Based System for Air Pollution Measurements
Villa, Tommaso Francesco; Salimi, Farhad; Morton, Kye; Morawska, Lidia; Gonzalez, Felipe
2016-01-01
Air quality data collection near pollution sources is difficult, particularly when sites are complex, have physical barriers, or are themselves moving. Small Unmanned Aerial Vehicles (UAVs) offer new approaches to air pollution and atmospheric studies. However, there are a number of critical design decisions which need to be made to enable representative data collection, in particular the location of the air sampler or air sensor intake. The aim of this research was to establish the best mounting point for four gas sensors and a Particle Number Concentration (PNC) monitor, onboard a hexacopter, so to develop a UAV system capable of measuring point source emissions. The research included two different tests: (1) evaluate the air flow behavior of a hexacopter, its downwash and upwash effect, by measuring air speed along three axes to determine the location where the sensors should be mounted; (2) evaluate the use of gas sensors for CO2, CO, NO2 and NO, and the PNC monitor (DISCmini) to assess the efficiency and performance of the UAV based system by measuring emissions from a diesel engine. The air speed behavior map produced by test 1 shows the best mounting point for the sensors to be alongside the UAV. This position is less affected by the propeller downwash effect. Test 2 results demonstrated that the UAV propellers cause a dispersion effect shown by the decrease of gas and PN concentration measured in real time. A Linear Regression model was used to estimate how the sensor position, relative to the UAV center, affects pollutant concentration measurements when the propellers are turned on. This research establishes guidelines on how to develop a UAV system to measure point source emissions. Such research should be undertaken before any UAV system is developed for real world data collection. PMID:28009820
Development and Validation of a UAV Based System for Air Pollution Measurements.
Villa, Tommaso Francesco; Salimi, Farhad; Morton, Kye; Morawska, Lidia; Gonzalez, Felipe
2016-12-21
Air quality data collection near pollution sources is difficult, particularly when sites are complex, have physical barriers, or are themselves moving. Small Unmanned Aerial Vehicles (UAVs) offer new approaches to air pollution and atmospheric studies. However, there are a number of critical design decisions which need to be made to enable representative data collection, in particular the location of the air sampler or air sensor intake. The aim of this research was to establish the best mounting point for four gas sensors and a Particle Number Concentration (PNC) monitor, onboard a hexacopter, so to develop a UAV system capable of measuring point source emissions. The research included two different tests: (1) evaluate the air flow behavior of a hexacopter, its downwash and upwash effect, by measuring air speed along three axes to determine the location where the sensors should be mounted; (2) evaluate the use of gas sensors for CO₂, CO, NO₂ and NO, and the PNC monitor (DISCmini) to assess the efficiency and performance of the UAV based system by measuring emissions from a diesel engine. The air speed behavior map produced by test 1 shows the best mounting point for the sensors to be alongside the UAV. This position is less affected by the propeller downwash effect. Test 2 results demonstrated that the UAV propellers cause a dispersion effect shown by the decrease of gas and PN concentration measured in real time. A Linear Regression model was used to estimate how the sensor position, relative to the UAV center, affects pollutant concentration measurements when the propellers are turned on. This research establishes guidelines on how to develop a UAV system to measure point source emissions. Such research should be undertaken before any UAV system is developed for real world data collection.
Lin, Tung-Cheng
2013-11-01
Online game playing may induce physiological effects. However, the physical mechanisms that cause these effects remain unclear. The purpose of this study was to examine the physiological effects of long-hour online gaming from an autonomic nervous system (ANS) perspective. Heart rate variability (HRV), a valid and noninvasive electrocardiographic method widely used to investigate ANS balance, was used to measure physiological effect parameters. This study used a five-time, repeated measures, mixed factorial design. Results found that playing violent games causes significantly higher sympathetic activity and diastolic blood pressure than playing nonviolent games. Long-hour online game playing resulted in the gradual dominance of the parasympathetic nervous system due to physical exhaustion. Gaming workload was found to modulate the gender effects, with males registering significantly higher sympathetic activity and females significantly higher parasympathetic activity in the higher gaming workload group.
Improving Control System Cyber-State Awareness using Known Secure Sensor Measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ondrej Linda; Milos Manic; Miles McQueen
Abstract—This paper presents design and simulation of a low cost and low false alarm rate method for improved cyber-state awareness of critical control systems - the Known Secure Sensor Measurements (KSSM) method. The KSSM concept relies on physical measurements to detect malicious falsification of the control systems state. The KSSM method can be incrementally integrated with already installed control systems for enhanced resilience. This paper reviews the previously developed theoretical KSSM concept and then describes a simulation of the KSSM system. A simulated control system network is integrated with the KSSM components. The effectiveness of detection of various intrusion scenariosmore » is demonstrated on several control system network topologies.« less
ϕ Meson Measurements at RHIC with the PHENIX Detector
NASA Astrophysics Data System (ADS)
Sarsour, Murad
2018-02-01
The measurement of ϕ mesons provides key information on the phase of the hot and dense medium created in the relativistic heavy ion collisions. It has a relatively small hadronic interaction cross section and is sensitive to the increase of strangeness (strangeness enhancement), a phenomenon associated with soft particles in bulk matter. Measurements in the dilepton channels are especially interesting since leptons interact only electromagnetically, thus carrying the information from their production phase directly to the detector. Measurements in different nucleus-nucleus collisions allow us to perform a systematic study of the nuclear medium effects on ϕ meson production. The PHENIX detector provides the capabilities to measure the ϕ meson production in a wide range of transverse momentum and rapidity to study these effects. In this proceeding, we present measurements of the ϕ mesons in a variety of collision systems at = 200 GeV. In case of small systems, the data are compared with AMPT calculations to study the various cold nuclear medium effects involved in ϕ meson production.
2015-12-01
10 IMU Inertial Measurement Unit . . . . . . . . . . . . . . . . . . . . . . . . . 11 PS Pseudo...filters to diminish the effect of gyro corruption in the inertial measurement unit ( IMU ) [32]. Therefore, s/c states determined by the hardware...simulator’s IMU hold the required level of accuracy for characterization of the RWCMG system in the current research. Future external state measurement systems
NASA Technical Reports Server (NTRS)
Johnson, Kimberly D.
1995-01-01
The objective of the first project involving the HYDRA laser system was to determine what effects, if any, could been seen in the system's measurements when testing was done with objects composed of different materials. Ideally we would like to have seen that the range of measurements were all within the accepted 0.4 millimeter accuracy of the system. Unfortunately our results were not as we had hoped, and there did appear to be some significant difference in the measurements made on objects composed of different materials. The second project is a continuing project at Old Dominion University. The ultimate goal is to develop a medical database that allows a doctor or hospital to keep medical records on line. The current data of the system consisted of one patient whose medical data had been hard coded to allow for a demonstration of the potentials of the system. The short term goal for this summer was to add additional patients to the system for testing, and to eliminate the hard coding of data by creating a database where data could be stored and queried to produce the results seen in the current state.
Effective Hamiltonian approach to the Kerr nonlinearity in an optomechanical system
NASA Astrophysics Data System (ADS)
Gong, Z. R.; Ian, H.; Liu, Yu-Xi; Sun, C. P.; Nori, Franco
2009-12-01
Using the Born-Oppenheimer approximation, we derive an effective Hamiltonian for an optomechanical system that leads to a nonlinear Kerr effect in the system’s vacuum. The oscillating mirror at one edge of the optomechanical system induces a squeezing effect in the intensity spectrum of the cavity field. A near-resonant laser field is applied at the other edge to drive the cavity field in order to enhance the Kerr effect. We also propose a quantum-nondemolition-measurement setup to monitor a system with two cavities separated by a common oscillating mirror based on our effective Hamiltonian approach.
Load measurement system with load cell lock-out mechanism
NASA Technical Reports Server (NTRS)
Le, Thang; Carroll, Monty; Liu, Jonathan
1995-01-01
In the frame work of the project Shuttle Plume Impingement Flight Experiment (SPIFEX), a Load Measurement System was developed and fabricated to measure the impingement force of Shuttle Reaction Control System (RCS) jets. The Load Measurement System is a force sensing system that measures any combination of normal and shear forces up to 40 N (9 lbf) in the normal direction and 22 N (5 lbf) in the shear direction with an accuracy of +/- 0.04 N (+/- 0.01 lbf) Since high resolution is required for the force measurement, the Load Measurement System is built with highly sensitive load cells. To protect these fragile load cells in the non-operational mode from being damaged due to flight loads such as launch and landing loads of the Shuttle vehicle, a motor driven device known as the Load Cell Lock-Out Mechanism was built. This Lock-Out Mechanism isolates the load cells from flight loads and re-engages the load cells for the force measurement experiment once in space. With this highly effective protection system, the SPIFEX load measurement experiment was successfully conducted on STS-44 in September 1994 with all load cells operating properly and reading impingement forces as expected.
Measurements of high-current electron beams from X pinches and wire array Z pinches.
Shelkovenko, T A; Pikuz, S A; Blesener, I C; McBride, R D; Bell, K S; Hammer, D A; Agafonov, A V; Romanova, V M; Mingaleev, A R
2008-10-01
Some issues concerning high-current electron beam transport from the X pinch cross point to the diagnostic system and measurements of the beam current by Faraday cups are discussed. Results of computer simulation of electron beam propagation from the pinch to the Faraday cup give limits for the measured current for beams having different energy spreads. The beam is partially neutralized as it propagates from the X pinch to a diagnostic system, but within a Faraday cup diagnostic, space charge effects can be very important. Experimental results show evidence of such effects.
Cotton-Mouton polarimeter with HCN laser on CHS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Akiyama, T.; Kawahata, K.; Ito, Y.
Polarimeters based on the Cotton-Mouton effect hold promise for electron density measurements. We have designed and installed a Cotton-Mouton polarimeter on the Compact Helical System. The Cotton-Mouton effect is measured as the phase difference between probe and reference beams. In this system, an interferometric measurement can be performed simultaneously with the same probe chord. The light source is a HCN laser (wavelength of 337 {mu}m). Digital complex demodulation is adopted for small phase analysis. The line averaged density evaluated from the polarimeter along a plasma center chord is almost consistent with that from the interferometer.
Methods to characterize charging effects
NASA Astrophysics Data System (ADS)
Slots, H.
1984-08-01
Methods to characterize charging in insulating material under high voltage dc stress, leading to electrical breakdown, are reviewed. The behavior of the charges can be studied by ac loss angle measurements after application or removal of dc bias. Measurements were performed on oil-paper and oil-Mylar systems. The poor reproducibility of the measurements makes it impossible to draw more than qualitative conclusions about the charging effects. With an ultrasound pressure wave the electric field distribution in a material can be determined. An alternative derivation for the transient response of a system which elucidates the influence of several parameters in a simple way is given.
Recent Research on the Automated Mass Measuring System
NASA Astrophysics Data System (ADS)
Yao, Hong; Ren, Xiao-Ping; Wang, Jian; Zhong, Rui-Lin; Ding, Jing-An
The research development of robotic measurement system as well as the representative automatic system were introduced in the paper, and then discussed a sub-multiple calibration scheme adopted on a fully-automatic CCR10 system effectively. Automatic robot system can be able to perform the dissemination of the mass scale without any manual intervention as well as the fast speed calibration of weight samples against a reference weight. At the last, evaluation of the expanded uncertainty was given out.
Sasaki, Satoshi; Iida, Yoshinori
2009-06-01
The effect of kinematic viscosity and surface tension of the solution was investigated by adding catalase, glucose oxidase, or glucose on the bubble movement in a catalase-hydrogen peroxide system. The kinematic viscosity was measured using a Cannon-Fenske kinematic viscometer. The surface tension of the solution was measured by the Wilhelmy method using a self-made apparatus. The effects of the hole diameter/cell wall thickness, catalase concentration, glucose concentration, and glucose oxidase concentration on the kinematic viscosity, surface tension, and bubble take-off period were investigated. With our system, the effects of the changes in the solution materiality on the bubble take-off period were proven to be very small in comparison to the change in the oxygen-producing rate.
Spieth, Hubert R; Xue, Fangsen; Strau, Katharina
2004-12-01
On the southern Iberian Peninsula, the seasonal life history of the large white butterfly, Pieris brassicae, comprises 2 different photoperiodically induced developmental arrests: a hibernation diapause at photophases < 11 h and an estivation diapause at photophases > 14 h. At intermediate photophases (12 h to 13 h), the butterfly responds with a nondiapause. Combined with the experimental setup to determine photosensitivity in insects, the different photoperiodic responses at long-, intermediate-, and short-night conditions were examined to gain more insight into the time measurement mechanism in P. brassicae. The study reveals evidence for a "double circadian oscillator clock" mechanism that is based on 2 submechanisms, a "short-night determining system" and a separate "long-night determining system." This conclusion was drawn from the facts that an LD 9:15 long-night induces a hibernation diapause but inhibits an estivation diapause and, conversely, that an LD 16:8 short-night inhibits a hibernation diapause but induces an estivation diapause. This opposite effect of the same photoperiod supports the argument for the existence of 2 independent targets for light-dark cycles, interpreted as 2 antagonistic time measurement systems. The existence and independence of 2 systems was further shown by differences in long-night versus short-night responses regarding photosensitivity, temperature dependence, and heritable factors. The long-night measurement system is most effective in the 5th larval stage, is highly affected by temperature, and is easy to manipulate by selective inbreeding. The short-night measurement system is most effective in the 4th larval stage, is largely temperature compensated, and is not affected by experimental manipulation of the longnight measurement system.
Critical issues encountered in experiments and measurements involving optical turbulence
NASA Astrophysics Data System (ADS)
Eaton, Frank D.
2007-02-01
The successful design and operation of high energy laser (HEL) and laser communication systems require a comprehensive and thorough knowledge of the real turbulent atmosphere coupled with high-fidelity realistic laser beam propagation models. To date, modeling and simulation of laser beam propagation through atmospheric turbulence have relied upon a traditional theoretical basis that assumes the existence of homogeneous, isotropic, stationary, and Kolmogorov turbulence. The real impact of the refractive index structure parameter ( C2 n ) on laser beam propagation including effects of non-classical turbulence as well as inner (l °) and outer scale (L °) effects will be examined. Observations clearly show turbulence is often layered and is produced by wave activity and episodic events such as Kelvin-Helmholtz instabilities. Other critical turbulence issues involve the relationship between mechanical and optical turbulence and the effect of path variability of turbulence and inner scale on optical turbulence parameters over long paths. These issues will be examined from data obtained from five systems: a) a new measurement platform using a free-flying balloon that lifts a ring with a boom upon which are mounted several fine wire (1-μm diameter) sensors to measure high-speed temperature and velocity fluctuations, b) a new system using a kite/tethered blimp platform that obtains both profile and measurements at a fixed altitude over time, c) a 50 MHz radar at Vandenberg Air Force Base that senses at high temporal and spatial resolution to 20 km ASL, d) an instrumented aircraft system, and e) a suite of optical systems. The first four systems all provide estimates of C2 n , the eddy dissipation rate (\\Vegr), l ° and L °. Methods of calibration and problems of interpreting results from the measurement systems are discussed.
Tuning quantum measurements to control chaos.
Eastman, Jessica K; Hope, Joseph J; Carvalho, André R R
2017-03-20
Environment-induced decoherence has long been recognised as being of crucial importance in the study of chaos in quantum systems. In particular, the exact form and strength of the system-environment interaction play a major role in the quantum-to-classical transition of chaotic systems. In this work we focus on the effect of varying monitoring strategies, i.e. for a given decoherence model and a fixed environmental coupling, there is still freedom on how to monitor a quantum system. We show here that there is a region between the deep quantum regime and the classical limit where the choice of the monitoring parameter allows one to control the complex behaviour of the system, leading to either the emergence or suppression of chaos. Our work shows that this is a result from the interplay between quantum interference effects induced by the nonlinear dynamics and the effectiveness of the decoherence for different measurement schemes.
Effects of distributed database modeling on evaluation of transaction rollbacks
NASA Technical Reports Server (NTRS)
Mukkamala, Ravi
1991-01-01
Data distribution, degree of data replication, and transaction access patterns are key factors in determining the performance of distributed database systems. In order to simplify the evaluation of performance measures, database designers and researchers tend to make simplistic assumptions about the system. The effect is studied of modeling assumptions on the evaluation of one such measure, the number of transaction rollbacks, in a partitioned distributed database system. Six probabilistic models and expressions are developed for the numbers of rollbacks under each of these models. Essentially, the models differ in terms of the available system information. The analytical results so obtained are compared to results from simulation. From here, it is concluded that most of the probabilistic models yield overly conservative estimates of the number of rollbacks. The effect of transaction commutativity on system throughout is also grossly undermined when such models are employed.
Effects of distributed database modeling on evaluation of transaction rollbacks
NASA Technical Reports Server (NTRS)
Mukkamala, Ravi
1991-01-01
Data distribution, degree of data replication, and transaction access patterns are key factors in determining the performance of distributed database systems. In order to simplify the evaluation of performance measures, database designers and researchers tend to make simplistic assumptions about the system. Here, researchers investigate the effect of modeling assumptions on the evaluation of one such measure, the number of transaction rollbacks in a partitioned distributed database system. The researchers developed six probabilistic models and expressions for the number of rollbacks under each of these models. Essentially, the models differ in terms of the available system information. The analytical results obtained are compared to results from simulation. It was concluded that most of the probabilistic models yield overly conservative estimates of the number of rollbacks. The effect of transaction commutativity on system throughput is also grossly undermined when such models are employed.
Quantifying alignment effects in 3D coordinate measurement.
DOT National Transportation Integrated Search
2009-10-01
The use of fixtureless, non-contact coordinate measurement has become increasingly prevalent in manufacturing : problem solving. Manufacturers now routinely use measurement systems such as white light area scanners, photogrammetry, : laser trackers, ...
1989-06-01
Force systems require a resolved information on the optical thorough understanding of the propaga- extinction coefficient. Measurements of tion path , the...Depolarization as Function of Snow Density. Measurement System ). (It correlated well with the ( Multi -scatter scale length information is usable to extinction ...data on the effect of optically thin cirrus clouds on long - path infrared transmit- tance. Future system designers will have access to this new
Measurement and modeling of moist processes
NASA Technical Reports Server (NTRS)
Cotton, William; Starr, David; Mitchell, Kenneth; Fleming, Rex; Koch, Steve; Smith, Steve; Mailhot, Jocelyn; Perkey, Don; Tripoli, Greg
1993-01-01
The keynote talk summarized five years of work simulating observed mesoscale convective systems with the RAMS (Regional Atmospheric Modeling System) model. Excellent results are obtained when simulating squall line or other convective systems that are strongly forced by fronts or other lifting mechanisms. Less highly forced systems are difficult to model. The next topic in this colloquium was measurement of water vapor and other constituents of the hydrologic cycle. Impressive accuracy was shown measuring water vapor with both the airborne DIAL (Differential Absorption Lidar) system and the the ground-based Raman Lidar. NMC's plans for initializing land water hydrology in mesoscale models was presented before water vapor measurement concepts for GCIP were discussed. The subject of using satellite data to provide mesoscale moisture and wind analyses was next. Recent activities in modeling of moist processes in mesoscale systems was reported on. These modeling activities at the Canadian Atmospheric Environment Service (AES) used a hydrostatic, variable-resolution grid model. Next the spatial resolution effects of moisture budgets was discussed; in particular, the effects of temporal resolution on heat and moisture budgets for cumulus parameterization. The conclusion of this colloquium was on modeling scale interaction processes.
System stability and calibrations for hand-held electromagnetic frequency domain instruments
NASA Astrophysics Data System (ADS)
Saksa, Pauli J.; Sorsa, Joona
2017-05-01
There are a few multiple-frequency domain electromagnetic induction (EMI) hand-held rigid boom systems available for shallow geophysical resistivity investigations. They basically measure secondary field real and imaginary components after the system calibrations. One multiple-frequency system, the EMP-400 Profiler from Geophysical Survey Systems Inc., was tested for system calibrations, stability and various effects present in normal measurements like height variation, tilting, signal stacking and time stability. Results indicated that in test conditions, repeatable high-accuracy imaginary component values can be recorded for near-surface frequency soundings. In test conditions, real components are also stable but vary strongly in normal surveying measurements. However, certain calibration issues related to the combination of user influence and measurement system height were recognised as an important factor in reducing for data errors and for further processing like static offset corrections.
Fitzgerald, Sarah; Murphy, Aileen; Kirby, Ann; Geaney, Fiona; Perry, Ivan J
2018-01-01
Objective To evaluate the costs, benefits and cost-effectiveness of complex workplace dietary interventions, involving nutrition education and system-level dietary modification, from the perspective of healthcare providers and employers. Design Single-study economic evaluation of a cluster-controlled trial (Food Choice at Work (FCW) study) with 1-year follow-up. Setting Four multinational manufacturing workplaces in Cork, Ireland. Participants 517 randomly selected employees (18–65 years) from four workplaces. Interventions Cost data were obtained from the FCW study. Nutrition education included individual nutrition consultations, nutrition information (traffic light menu labelling, posters, leaflets and emails) and presentations. System-level dietary modification included menu modification (restriction of fat, sugar and salt), increase in fibre, fruit discounts, strategic positioning of healthier alternatives and portion size control. The combined intervention included nutrition education and system-level dietary modification. No intervention was implemented in the control. Outcomes The primary outcome was an improvement in health-related quality of life, measured using the EuroQoL 5 Dimensions 5 Levels questionnaire. The secondary outcome measure was reduction in absenteeism, which is measured in monetary amounts. Probabilistic sensitivity analysis (Monte Carlo simulation) assessed parameter uncertainty. Results The system-level intervention dominated the education and combined interventions. When compared with the control, the incremental cost-effectiveness ratio (€101.37/quality-adjusted life-year) is less than the nationally accepted ceiling ratio, so the system-level intervention can be considered cost-effective. The cost-effectiveness acceptability curve indicates there is some decision uncertainty surrounding this, arising from uncertainty surrounding the differences in effectiveness. These results are reiterated when the secondary outcome measure is considered in a cost–benefit analysis, whereby the system-level intervention yields the highest net benefit (€56.56 per employee). Conclusions System-level dietary modification alone offers the most value per improving employee health-related quality of life and generating net benefit for employers by reducing absenteeism. While system-level dietary modification strategies are potentially sustainable obesity prevention interventions, future research should include long-term outcomes to determine if improvements in outcomes persist. Trial registration number ISRCTN35108237; Post-results. PMID:29502090
Multi-Hazard Assessment of Scour Damaged Bridges with UAS-Based Measurements
NASA Astrophysics Data System (ADS)
Özcan, O.; Ozcan, O.
2017-12-01
Flood and stream induced scour occurring in bridge piers constructed on rivers is one of the mostly observed failure reasons in bridges. Scour induced failure risk in bridges and determination of the alterations in bridge safety under seismic effects has the ultimate importance. Thus, for the determination of bridge safety under the scour effects, the scour amount under bridge piers should be designated realistically and should be tracked and updated continuously. Hereby, the scour induced failures in bridge foundation systems will be prevented and bridge substructure design will be conducted safely. In this study, in order to measure the amount of scour in bridge load bearing system (pile foundations and pile abutments) and to attain very high definition 3 dimensional models of river flood plain for the flood analysis, unmanned aircraft system (UAS) based measurement methods were implemented. UAS based measurement systems provide new and practical approach and bring high precision and reliable solutions considering recent measurement systems. For this purpose, the reinforced concrete (RC) bridge that is located on Antalya Boğaçayı River, Turkey and that failed in 2003 due to flood-induced scour was selected as the case study. The amount of scour occurred in bridge piers and piles was determined realistically and the behavior of bridge piers under scour effects was investigated. Future flood effects and the resultant amount of scour was determined with HEC-RAS software by using digital surface models that were obtained at regular intervals using UAS for the riverbed. In the light of the attained scour measurements and expected scour after a probable flood event, the behavior of scour damaged RC bridge was investigated by pushover and time history analyses under lateral and vertical seismic loadings. In the analyses, the load and displacement capacity of bridge was observed to diminish significantly under expected scour. Thus, the deterioration in multi hazard performance of the bridge was monitored significantly in the light of updated bridge load bearing system capacity. Regarding the case study, UAS based and continuously updated bridge multi hazard risk detection system was established that can be used for bridges located on riverbed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, A.; Santoso, S.; Muljadi, E.
2013-08-01
A network of multiple phasor measurement units (PMU) was created, set up, and maintained at the University of Texas at Austin to obtain actual power system measurements for power system analysis. Power system analysis in this report covers a variety of time ranges, such as short- term analysis for power system disturbances and their effects on power system behavior and long- term power system behavior using modal analysis. The first objective of this report is to screen the PMU data for events. The second objective of the report is to identify and describe common characteristics extracted from power system eventsmore » as measured by PMUs. The numerical characteristics for each category and how these characteristics are used to create selection rules for the algorithm are also described. Trends in PMU data related to different levels and fluctuations in wind power output are also examined.« less
NASA Astrophysics Data System (ADS)
Chambers, J. E.; Meldrum, P.; Gunn, D.; Wilkinson, P. B.; Uhlemann, S.; Swift, R. T.; Kuras, O.; Inauen, C.; Hutchinson, D.; Butler, S.
2016-12-01
ERT monitoring has been demonstrated in numerous studies as an effective means of imaging near surface processes for applications as diverse as permafrost studies and contaminated land assessment. A limiting factor in applying time-lapse ERT for long-term studies in remote locations has been the availability of cost-effective ERT measurement systems designed specifically for monitoring applications. Typically, monitoring is undertaken using repeated manual data collection, or by building conventional survey instruments into a monitoring setup. The latter often requires high power and is therefore difficult to operate remotely without access to mains electricity. We describe the development of a low-power resistivity imaging system designed specifically for remote monitoring, taking advantage of, e.g., solar power and data telemetry. Here, we present the results of two field deployments. The system has been installed on an active railway cutting to provide insights into the effect of vegetation on the moisture dynamics in unstable infrastructure slopes and to gather subsurface information for pro-active remediation measures. The system, comprising 255 electrodes, acquires 4596 reciprocal measurement pairs twice daily during standard operation. In case of severe weather events, the measurement schedule is reactively changed, to gather high temporal resolution data to image rainfall infiltration processes. The system has also been installed along a leaking and marginally stable canal embankment; a less favourable location for remote monitoring, with limited solar power and poor mobile reception. Nevertheless, the acquired data indicated the effectiveness of remedial actions on the canal. The ERT results showed that one leak was caused by the canal and fixed during remediation, while two other "leaks" were shown to be effects of groundwater dynamics. The availability of cost-effective, low-power ERT monitoring instrumentation, combined with an automated workflow of data processing and visualisation, has the potential to contribute to a step-change in the management and early warning of slope instability.
Electromagnetic shielding of thermal protection system for hypersonic vehicles
NASA Astrophysics Data System (ADS)
Albano, M.; Micheli, D.; Gradoni, G.; Morles, R. B.; Marchetti, M.; Moglie, F.; Mariani Primiani, V.
2013-06-01
The numerical simulation and the measurement of electromagnetic shielding at microwave frequencies of thermal protection system for hypersonic vehicles is presented using nested reverberation chamber. An example of a possible thermal protection system for a re-entry vehicle is presented. This system based on carbon material is electromagnetically characterized. The characterization takes into account not only the materials but also the final assembly configuration of the thermal protection system. The frequency range is 2-8 GHz. The results of measurements and simulations show that the microwave shielding effectiveness of carbon materials is above 60 dB for a single tile and that the tile inter-distance is able to downgrade the shielding effectiveness on the average to about 40 dB.
Comparison between pulse wave velocities measured using Complior and measured using Biopac.
van Velzen, Marit H N; Stolker, Robert Jan; Loeve, Arjo J; Niehof, Sjoerd P; Mik, Egbert G
2018-06-06
Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed around the neck and the wrist. The Biopac system is an easier to use alternative that uses ECG and simple optical sensors to measure the PWV between the heart and the fingertips, and thus extends a bit more to the peripheral vasculature compared to the Complior system. The goal of this study was to test under various conditions to what extent these systems provide comparable and correlating values. 25 Healthy volunteers, 20-30 years old, were measured in four sequential position: sitting, lying, standing and sitting. The results showed that the Biopac system measured consistently and significantly lower PWV values than the Complior system, for all positions. Correlation values and Bland-Altman plots showed that despite the difference in PWV magnitudes obtained by the two systems the measurements did agree well. Which implies that as long as the differences in PWV magnitudes are taken into account, either system could be used to measure PWV changes over time. However, when basing diagnosis on absolute PWV values, one should be very much aware of how the PWV was measured and with what system.
The Conduct System and Its Infuence on Student Learning
ERIC Educational Resources Information Center
Stimpson, Matthew T.; Janosik, Steven M.
2015-01-01
In this study, 7 items were used to define a composite variable that measures the perceived effectiveness of student conduct systems. Multivariate Analysis of Variance (MANOVA) was used to test the relationship between perceived level of system effectiveness and self-reported student learning. In the analyses, 49% of the variance in reported…
DOT National Transportation Integrated Search
1977-07-01
The workshop focused on current methods of assessing the effectiveness of crime and vandalism reduction methods that are used in conventional urban mass transit systems, and on how they might be applied to new AGT systems. Conventional as well as nov...
The effect of vacuum devices on penile hemodynamics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katz, P.G.; Haden, H.T.; Mulligan, T.
1990-01-01
External vacuum devices are being used increasingly for the management of erectile dysfunction. There is limited information regarding the effect of vacuum devices on penile blood flow and potential for ischemic penile injury. The penile xenon washout rate was measured before and after application of 2 vacuum systems in 15 subjects. Compared to flaccid state measurements the xenon washout rate did not change significantly with the Synergist Erection System but it was significantly reduced with the Osbon ErecAid System. However, the degree and duration of decrease in penile blood flow that may result in ischemic changes are unknown.
Design of Measure and Control System for Precision Pesticide Deploying Dynamic Simulating Device
NASA Astrophysics Data System (ADS)
Liang, Yong; Liu, Pingzeng; Wang, Lu; Liu, Jiping; Wang, Lang; Han, Lei; Yang, Xinxin
A measure and control system for precision deploying pesticide simulating equipment is designed in order to study pesticide deployment technology. The system can simulate every state of practical pesticide deployment, and carry through precise, simultaneous measure to every factor affecting pesticide deployment effects. The hardware and software incorporates a structural design of modularization. The system is divided into many different function modules of hardware and software, and exploder corresponding modules. The modules’ interfaces are uniformly defined, which is convenient for module connection, enhancement of system’s universality, explodes efficiency and systemic reliability, and make the program’s characteristics easily extended and easy maintained. Some relevant hardware and software modules can be adapted to other measures and control systems easily. The paper introduces the design of special numeric control system, the main module of information acquisition system and the speed acquisition module in order to explain the design process of the module.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miles McQueen; Annarita Giani
2011-09-01
This paper describes a first investigation on a low cost and low false alarm, reliable mechanism for detecting manipulation of critical physical processes and falsification of system state. We call this novel mechanism Known Secure Sensor Measurements (KSSM). The method moves beyond analysis of network traffic and host based state information, in fact it uses physical measurements of the process being controlled to detect falsification of state. KSSM is intended to be incorporated into the design of new, resilient, cost effective critical infrastructure control systems. It can also be included in incremental upgrades of already in- stalled systems for enhancedmore » resilience. KSSM is based on known secure physical measurements for assessing the likelihood of an attack and will demonstrate a practical approach to creating, transmitting, and using the known secure measurements for detection.« less
NASA Astrophysics Data System (ADS)
Sadot, Dan; Zaarur, O.; Zaarur, S.; Kopeika, Norman S.
1994-10-01
An active method is presented for measuring atmospheric transmittance with an imaging system. In comparison to other measurement methods, this method has the advantage of immunity to background noise, independence of atmospheric conditions such as solar radiation, and an improved capability to evaluate effects of turbulence on the measurements. Other significant advantages are integration over all particulate size distribution effects including very small and very large particulates whose concentration is hard to measure, and the fact that this method is a path-integrated measurement. In this implementation attenuation deriving from molecular absorption and from small and large particulate scatter and absorption and their weather dependences are separated out. Preliminary results indicate high correlation with direct transmittance calculations via particle size distribution measurement, and that even at 10.6 micrometers wavelength atmospheric transmission depends noticeably on aerosol size distribution and concentration.
NASA Astrophysics Data System (ADS)
Sadot, D.; Zaarur, O.; Zaarur, S.
1995-12-01
An active method is presented for measuring atmospheric transmittance with an imaging system. In comparison to other measurement methods, this method has the advantage of immunity to background noise, independence of atmospheric conditions such as solar radiation, and an improved capability to evaluate effects of turbulence on the measurements. Other significant advantages are integration over all particulate size distribution effects including very small and very large particulates whose concentration is hard to measure, and the fact that this method is a path-integrated measurement. Attenuation deriving from molecular absorption and from small and large particulate scatter and absorption and their weather dependences are separated out. Preliminary results indicate high correlation with direct transmittance calculations via particle size distribution measurement, and that even at 10.6 μm wavelength atmospheric transmission depends noticeably on aerosol size distribution and concentration.
Downward-deployed tethered satellite systems, measurement techniques, and instrumentation - A review
NASA Technical Reports Server (NTRS)
Brown, Kenneth G.; Melfi, Leonard T., Jr.; Upchurch, Billy T.; Wood, George M., Jr.
1992-01-01
This paper describes a number of scheduled and proposed Shuttle-based downward-deployed tethered satellite systems (TSSs) the purpose of which is to determine the structure of the lower thermosphere and to measure the atmospheric and aerodynamic effects in the vicinity of the satellite, the aerothermodynamic effects on the satellite's surface, and the dynamics of the tether and its endmass, the satellite. The instruments for the downward-deployed tethered missions will include mass spectrometers and other density sensors, plasma instrumentation, optical spectrophotometers, magnetometers, and instrumentation to measure the effects on satellite surface (such as the surface temperature, heat transfer, and pressure; gas adsorption on surfaces, chemistry with other gas molecules and surface material, and desorption from the surface; and surface charging).
Calibration Techniques for Accurate Measurements by Underwater Camera Systems
Shortis, Mark
2015-01-01
Calibration of a camera system is essential to ensure that image measurements result in accurate estimates of locations and dimensions within the object space. In the underwater environment, the calibration must implicitly or explicitly model and compensate for the refractive effects of waterproof housings and the water medium. This paper reviews the different approaches to the calibration of underwater camera systems in theoretical and practical terms. The accuracy, reliability, validation and stability of underwater camera system calibration are also discussed. Samples of results from published reports are provided to demonstrate the range of possible accuracies for the measurements produced by underwater camera systems. PMID:26690172
Assuring the required spectroradiometric characteristics of the Fragment multispectral system
NASA Astrophysics Data System (ADS)
Bogdanov, A. A.; Kuzmin, V. I.; Mosevnina, L. G.; Popkov, A. V.; Sychev, A. G.; Tarnopolskii, V. I.
The paper examines methods and equipment for assuring the required spectroradiometric characteristics of the satellite-borne Fragment multispectral scanning system during development, fabrication, and autonomous and complex testing. These characteristics comprise: (1) the integrated sensitivity of the measuring channels to the spectral density of brightness (SDB): (2) the relative spectral sensitivity of the channels; (3) the effective spectral width of the sensitivity intervals and their position in the spectral range; (4) maximum values of SDB measured by the system in each spectral interval of sensitivity; (5) the SNR in each measuring channel; and (6) the relative rms of SDB measurements.
NASA Technical Reports Server (NTRS)
Frohberg, M. G.; Betz, G.
1982-01-01
A method was tested for measuring the enthalpies of mixing of liquid metallic alloying systems, involving the combination of two samples in the electromagnetic field of an induction coil. The heat of solution is calculated from the pyrometrically measured temperature effect, the heat capacity of the alloy, and the heat content of the added sample. The usefulness of the method was tested experimentally with iron-copper and niobium-silicon systems. This method should be especially applicable to high-melting alloys, for which conventional measurements have failed.
Schawo, Saskia J; van Eeren, Hester; Soeteman, Djira I; van der Veldt, Marie-Christine; Noom, Marc J; Brouwer, Werner; Busschbach, Jan J V; Hakkaart, Leona
2012-12-01
Many interventions initiated within and financed from the health care sector are not necessarily primarily aimed at improving health. This poses important questions regarding the operationalisation of economic evaluations in such contexts. We investigated whether assessing cost-effectiveness using state-of-the-art methods commonly applied in health care evaluations is feasible and meaningful when evaluating interventions aimed at reducing youth delinquency. A probabilistic Markov model was constructed to create a framework for the assessment of the cost-effectiveness of systemic interventions in delinquent youth. For illustrative purposes, Functional Family Therapy (FFT), a systemic intervention aimed at improving family functioning and, primarily, reducing delinquent activity in youths, was compared to Treatment as Usual (TAU). "Criminal activity free years" (CAFYs) were introduced as central outcome measure. Criminal activity may e.g. be based on police contacts or committed crimes. In absence of extensive data and for illustrative purposes the current study based criminal activity on available literature on recidivism. Furthermore, a literature search was performed to deduce the model's structure and parameters. Common cost-effectiveness methodology could be applied to interventions for youth delinquency. Model characteristics and parameters were derived from literature and ongoing trial data. The model resulted in an estimate of incremental costs/CAFY and included long-term effects. Illustrative model results point towards dominance of FFT compared to TAU. Using a probabilistic model and the CAFY outcome measure to assess cost-effectiveness of systemic interventions aimed to reduce delinquency is feasible. However, the model structure is limited to three states and the CAFY measure was defined rather crude. Moreover, as the model parameters are retrieved from literature the model results are illustrative in the absence of empirical data. The current model provides a framework to assess the cost-effectiveness of systemic interventions, while taking into account parameter uncertainty and long-term effectiveness. The framework of the model could be used to assess the cost-effectiveness of systemic interventions alongside (clinical) trial data. Consequently, it is suitable to inform reimbursement decisions, since the value for money of systemic interventions can be demonstrated using a decision analytic model. Future research could be focussed on testing the current model based on extensive empirical data, improving the outcome measure and finding appropriate values for that outcome.
Effectiveness of the Civil Aviation Security Program.
1979-04-25
the airline and airport security measures in effect. Moreover, of the 25 U.S. airline hijackings that occurred over this 6-year period, none was caused...Furthermore, it is estimated that 75 hijackings or related crimes may have been prevented by the airline and airport security measures in effect...system. Moreover, it is estimated that at least 75 hijackings or related crimes may have been prevented by U.S. airline and airport security measures
Data fusion algorithm for rapid multi-mode dust concentration measurement system based on MEMS
NASA Astrophysics Data System (ADS)
Liao, Maohao; Lou, Wenzhong; Wang, Jinkui; Zhang, Yan
2018-03-01
As single measurement method cannot fully meet the technical requirements of dust concentration measurement, the multi-mode detection method is put forward, as well as the new requirements for data processing. This paper presents a new dust concentration measurement system which contains MEMS ultrasonic sensor and MEMS capacitance sensor, and presents a new data fusion algorithm for this multi-mode dust concentration measurement system. After analyzing the relation between the data of the composite measurement method, the data fusion algorithm based on Kalman filtering is established, which effectively improve the measurement accuracy, and ultimately forms a rapid data fusion model of dust concentration measurement. Test results show that the data fusion algorithm is able to realize the rapid and exact concentration detection.
USDA-ARS?s Scientific Manuscript database
The LI-6400 gas exchange system (Li-Cor, Inc, Lincoln, NE, USA) has been widely used for the measurement of net gas exchanges and calibration/parameterization of leaf models. Measurement errors due to diffusive leakages of water vapor and carbon dioxide between inside and outside of the leaf chamber...
NASA Technical Reports Server (NTRS)
Fulton, C. L.; Harris, R. L., Jr.
1980-01-01
Factors that can affect oculometer measurements of pupil diameter are: horizontal (azimuth) and vertical (elevation) viewing angle of the pilot; refraction of the eye and cornea; changes in distance of eye to camera; illumination intensity of light on the eye; and counting sensitivity of scan lines used to measure diameter, and output voltage. To estimate the accuracy of the measurements, an artificial eye was designed and a series of runs performed with the oculometer system. When refraction effects are included, results show that pupil diameter is a parabolic function of the azimuth angle similar to the cosine function predicted by theory: this error can be accounted for by using a correction equation, reducing the error from 6% to 1.5% of the actual diameter. Elevation angle and illumination effects were found to be negligible. The effects of counting sensitivity and output voltage can be calculated directly from system documentation. The overall accuracy of the unmodified system is about 6%. After correcting for the azimuth angle errors, the overall accuracy is approximately 2%.
Frehmann, T; Niemann, A; Ustohal, P; Geiger, W F
2002-01-01
Four individual mathematical submodels simulating different subsystems of urban drainage were intercoupled to an integral model. The submodels (for surface runoff, flow in sewer system, wastewater treatment plant and receiving water) were calibrated on the basis of field data measured in an existing urban catchment investigation. Three different strategies for controlling the discharge in the sewer network were defined and implemented in the integral model. The impact of these control measures was quantified by representative immission state-parameters of the receiving water. The results reveal that the effect of a control measure may be ambivalent, depending on the referred component of a complex drainage system. Furthermore, it is demonstrated that the drainage system in the catchment investigation can be considerably optimised towards environmental protection and operation efficiency if an appropriate real time control on the integral scale is applied.
Optimal Correlations in Many-Body Quantum Systems
NASA Astrophysics Data System (ADS)
Amico, L.; Rossini, D.; Hamma, A.; Korepin, V. E.
2012-06-01
Information and correlations in a quantum system are closely related through the process of measurement. We explore such relation in a many-body quantum setting, effectively bridging between quantum metrology and condensed matter physics. To this aim we adopt the information-theory view of correlations and study the amount of correlations after certain classes of positive-operator-valued measurements are locally performed. As many-body systems, we consider a one-dimensional array of interacting two-level systems (a spin chain) at zero temperature, where quantum effects are most pronounced. We demonstrate how the optimal strategy to extract the correlations depends on the quantum phase through a subtle interplay between local interactions and coherence.
Effects of System Timing Parameters on Operator Performance in a Personnel Records Task
1981-03-01
work sampling, embedded performance measures, and operator satisfaction ratings) are needed to provide a complete analysis of the effects of the four...HFL-8 l-l/NPRDC-8 1-1 March 1981 EFFECTS OF SYSTEM TIMING PARAMETERS ON OPERATOR PERFORMANCE IN A PERSONNEL RECORDS TASK Robert C. Williges Beverly H...and Subtitle) S. TYPE OF REPORT & PERIOD COVERED EFFECTS OF SYSTEM TIMING PARAMETERS ON OPERATOR PERFORMANCE IN A PERSONNEL RECORDS TASK Final
Measurement of control system response using an analog operational circuit
NASA Technical Reports Server (NTRS)
Lalli, V. R.
1978-01-01
Ten basic steps are established for an analog method that measures control system response parameters. An example shows how these steps were used on a speed control portion of an auxiliary power unit. The equations and calculations necessary to describe this subsystem are given. The mechanization schematic and simulation diagram for obtaining the measured response parameters of the control system using an analog circuit are explained. Methods for investigating the various effects of the control parameters are described. It is concluded that the optimum system should be underdamped enough to be slightly oscillatory during transients.
DOT National Transportation Integrated Search
2008-12-08
The objective of this research is to develop a general methodological framework for planning and : evaluating the effectiveness of highway reconstruction strategies on the systems performance : measures, in particular safety, mobility, and the tot...
EVALUATION OF THE HIGH VOLUME COLLECTION SYSTEM (HVCS) FOR QUANTIFYING FUGITIVE ORGANIC VAPOR LEAKS
The report discusses a recently developed measurements technique that offers the potential for providing an easy-to-use and cost effective means to directly measure organic vapor leaks. The method, called High Volume Collection System (HVCS), uses a high volume sampling device an...
Culturally grounded indicators of resilience in social-ecological systems
Eleanor Sterling; Tamara Ticktin; Tē Kipa Kepa Morgan; Georgina Cullman; Diana Alvira; Pelika Andrade; Nadia Bergamini; Erin Betley; Kate Burrows; Sophie Caillon; Joachim Claudet; Rachel Dacks; Pablo Eyzaguirre; Chris Filardi; Nadav Gazit; Christian Giardina; Stacy Jupiter; Kealohanuiopuna Kinney; Joe McCarter; Manuel Mejia; Kanoe Morishige; Jennifer Newell; Lihla Noori; John Parks; Pua‘ala Pascua; Ashwin Ravikumar; Jamie Tanguay; Amanda Sigouin; Tina Stege; Mark Stege; Alaka Wali
2017-01-01
Measuring progress toward sustainability goals is a multifaceted task. International, regional, and national organizations and agencies seek to promote resilience and capacity for adaptation at local levels. However, their measurement systems may be poorly aligned with local contexts, cultures, and needs. Understanding how to build effective, culturally grounded...
A compact x-ray system for two-phase flow measurement
NASA Astrophysics Data System (ADS)
Song, Kyle; Liu, Yang
2018-02-01
In this paper, a compact x-ray densitometry system consisting of a 50 kV, 1 mA x-ray tube and several linear detector arrays is developed for two-phase flow measurement. The system is capable of measuring void fraction and velocity distributions with a spatial resolution of 0.4 mm per pixel and a frequency of 1000 Hz. A novel measurement model has been established for the system which takes account of the energy spectrum of x-ray photons and the beam hardening effect. An improved measurement accuracy has been achieved with this model compared with the conventional log model that has been widely used in the literature. Using this system, void fraction and velocity distributions are measured for a bubbly and a slug flow in a 25.4 mm I.D. air-water two-phase flow test loop. The measured superficial gas velocities show an error within ±4% when compared with the gas flowmeter for both conditions.
Collection and processing of data from a phase-coherent meteor radar
NASA Technical Reports Server (NTRS)
Backof, C. A., Jr.; Bowhill, S. A.
1974-01-01
An analysis of the measurement accuracy requirement of a high resolution meteor radar for observing short period, atmospheric waves is presented, and a system which satisfies the requirements is described. A medium scale, real time computer is programmed to perform all echo recognition and coordinate measurement functions. The measurement algorithms are exercised on noisy data generated by a program which simulates the hardware system, in order to find the effects of noise on the measurement accuracies.
Casanova-Moreno, J; Bizzotto, D
2015-02-17
Electrostatic control of the orientation of fluorophore-labeled DNA strands immobilized on an electrode surface has been shown to be an effective bioanalytical tool. Modulation techniques and later time-resolved measurements were used to evaluate the kinetics of the switching between lying and standing DNA conformations. These measurements, however, are the result of a convolution between the DNA "switching" response time and the other frequency limited responses in the measurement. In this work, a method for analyzing the response of a potential driven DNA sensor is presented by calculating the potential effectively dropped across the electrode interface (using electrochemical impedance spectroscopy) as opposed to the potential applied to the electrochemical cell. This effectively deconvolutes the effect of the charging time on the observed frequency response. The corrected response shows that DNA is able to switch conformation faster than previously reported using modulation techniques. This approach will ensure accurate measurements independent of the electrochemical system, removing the uncertainty in the analysis of the switching response, enabling comparison between samples and measurement systems.
Remote Vibration Measurements at a Sud Aviation Alouette III Helicopter with a CW CO2-Laser System
1993-09-28
mrad and a continuous output of 0.4 Watt. The purpose of our measurements was to measure the vibration spectra of a helicopter from the Dutch Air Force...detection 13 3.2.1 Non-linear effects in vibrometry 15 4 THE VIBRATION SOURCES OF A HELICOPTER 24 5 MEASUREMENTS 29 5.1 Measuring Method 29 5.2 Scenario...vibration in Hz. 3.2.1 Non-linear effects in vibrometry A brief explanation of the non-linear effects is given below. A FM receiver has a built-in limiter
NASA Technical Reports Server (NTRS)
Johnson, Stephen B.; Ghoshal, Sudipto; Haste, Deepak; Moore, Craig
2017-01-01
This paper describes the theory and considerations in the application of metrics to measure the effectiveness of fault management. Fault management refers here to the operational aspect of system health management, and as such is considered as a meta-control loop that operates to preserve or maximize the system's ability to achieve its goals in the face of current or prospective failure. As a suite of control loops, the metrics to estimate and measure the effectiveness of fault management are similar to those of classical control loops in being divided into two major classes: state estimation, and state control. State estimation metrics can be classified into lower-level subdivisions for detection coverage, detection effectiveness, fault isolation and fault identification (diagnostics), and failure prognosis. State control metrics can be classified into response determination effectiveness and response effectiveness. These metrics are applied to each and every fault management control loop in the system, for each failure to which they apply, and probabilistically summed to determine the effectiveness of these fault management control loops to preserve the relevant system goals that they are intended to protect.
Viscosity of SiO2-"FeO"-Al2O3 System in Equilibrium with Metallic Fe
NASA Astrophysics Data System (ADS)
Chen, Mao; Raghunath, Sreekanth; Zhao, Baojun
2013-08-01
The present study delivered the measurements of viscosities in SiO2-"FeO"-Al2O3 system in equilibrium with metallic Fe. The rotational spindle technique was used in the measurements at the temperature range of 1473 K to 1773 K (1200 °C to 1500 °C). Molybdenum crucibles and spindles were employed in all measurements. The Fe saturation condition was maintained by an iron plate placed at the bottom of the crucible. The equilibrium compositions of the slags were measured by EPMA after the viscosity measurements. The effect of up to 20 mol. pct Al2O3 on the viscosity of the SiO2-"FeO" slag was investigated. The "charge compensation effect" of the Al2O3 and FeO association has been discussed. The modified quasi-chemical viscosity model has been optimized in the SiO2-"FeO"-Al2O3 system in equilibrium with metallic Fe to describe the viscosity measurements of the present study.
In large epidemiological studies, many researchers use surrogates of air pollution exposure such as geographic information system (GIS)-based characterizations of traffic or simple housing characteristics. It is important to validate these surrogates against measured pollutant co...
Study of multi-functional precision optical measuring system for large scale equipment
NASA Astrophysics Data System (ADS)
Jiang, Wei; Lao, Dabao; Zhou, Weihu; Zhang, Wenying; Jiang, Xingjian; Wang, Yongxi
2017-10-01
The effective application of high performance measurement technology can greatly improve the large-scale equipment manufacturing ability. Therefore, the geometric parameters measurement, such as size, attitude and position, requires the measurement system with high precision, multi-function, portability and other characteristics. However, the existing measuring instruments, such as laser tracker, total station, photogrammetry system, mostly has single function, station moving and other shortcomings. Laser tracker needs to work with cooperative target, but it can hardly meet the requirement of measurement in extreme environment. Total station is mainly used for outdoor surveying and mapping, it is hard to achieve the demand of accuracy in industrial measurement. Photogrammetry system can achieve a wide range of multi-point measurement, but the measuring range is limited and need to repeatedly move station. The paper presents a non-contact opto-electronic measuring instrument, not only it can work by scanning the measurement path but also measuring the cooperative target by tracking measurement. The system is based on some key technologies, such as absolute distance measurement, two-dimensional angle measurement, automatically target recognition and accurate aiming, precision control, assembly of complex mechanical system and multi-functional 3D visualization software. Among them, the absolute distance measurement module ensures measurement with high accuracy, and the twodimensional angle measuring module provides precision angle measurement. The system is suitable for the case of noncontact measurement of large-scale equipment, it can ensure the quality and performance of large-scale equipment throughout the process of manufacturing and improve the manufacturing ability of large-scale and high-end equipment.
NASA Astrophysics Data System (ADS)
Chen, Biao; Ruth, Chris; Jing, Zhenxue; Ren, Baorui; Smith, Andrew; Kshirsagar, Ashwini
2014-03-01
Breast density has been identified to be a risk factor of developing breast cancer and an indicator of lesion diagnostic obstruction due to masking effect. Volumetric density measurement evaluates fibro-glandular volume, breast volume, and breast volume density measures that have potential advantages over area density measurement in risk assessment. One class of volume density computing methods is based on the finding of the relative fibro-glandular tissue attenuation with regards to the reference fat tissue, and the estimation of the effective x-ray tissue attenuation differences between the fibro-glandular and fat tissue is key to volumetric breast density computing. We have modeled the effective attenuation difference as a function of actual x-ray skin entrance spectrum, breast thickness, fibro-glandular tissue thickness distribution, and detector efficiency. Compared to other approaches, our method has threefold advantages: (1) avoids the system calibration-based creation of effective attenuation differences which may introduce tedious calibrations for each imaging system and may not reflect the spectrum change and scatter induced overestimation or underestimation of breast density; (2) obtains the system specific separate and differential attenuation values of fibroglandular and fat for each mammographic image; and (3) further reduces the impact of breast thickness accuracy to volumetric breast density. A quantitative breast volume phantom with a set of equivalent fibro-glandular thicknesses has been used to evaluate the volume breast density measurement with the proposed method. The experimental results have shown that the method has significantly improved the accuracy of estimating breast density.
Buchhalter, A R; Eissenberg, T
2000-02-01
Tobacco companies are responding to public pressure to market less dangerous and aversive products by developing novel smoking systems. The short- and long-term effects of these systems must be evaluated to determine the risks inherent in their use. One such system, the Accord, uses a hand-held device to heat tobacco electronically and is marketed as a means to reduce second-hand smoke. In this study 10 cigarette smokers (> or = 10 cigarettes per day) were recruited to evaluate the short-term effects produced when using this system. Subjects abstained from smoking for at least 8 h before participating in two experimental sessions where they smoked either their usual brand or used the Accord at 30-min intervals for 2 hours. Subject-rated measures of tobacco withdrawal and craving, physiological measures, and smoking behavior were assessed within each session. Results show that, when using the Accord, the magnitude of smoking-induced craving reductions and the physiological effects of smoking were less, and puff volume and frequency were greater than when subjects smoked their own brand of cigarettes. The expired air carbon monoxide increases observed after smoking own brand cigarettes did not occur after using the Accord. The novel system does not provide maximal withdrawal suppression and produces little increase in expired air carbon monoxide; physiological data suggest that the novel system may deliver nicotine less efficiently than normally marketed cigarettes. Smokers using the Accord system may smoke more often or more intensely to compensate for decreased withdrawal suppression and/or nicotine delivery.
Cost-Efficient Phase Noise Measurement
NASA Astrophysics Data System (ADS)
Perić, Ana; Bjelica, Milan
2014-05-01
In this paper, an automated system for oscillator phase noise measurement is described. The system is primarily intended for use in academic institutions, such as smaller university or research laboratories, as it deploys standard spectrum analyzer and free software. A method to compensate the effect of instrument intrinsic noise is proposed. Through series of experimental tests, good performances of our system are verified and compliance to theoretical expectations is demonstrated.
NASA Technical Reports Server (NTRS)
1988-01-01
The in-situ optical surface measurement system is a facility designed to study the deleterious effects of particulate materials on the surface reflectivities of optical materials in the vacuum ultraviolet (VUV). This arrangement is designed to simulate the on-orbit effects of contamination and degradation of optical surfaces. This simulation is accomplished through the use of non-coherent VUV sources illuminating optical surfaces located in a high vacuum chamber. Several sources of contamination are employed. The reflectivity is measured both at the specular reflection as well as at two scattered positions, forward and reverse. The system components are described and an operating procedure is given.
Leak detection by mass balance effective for Norman Wells line
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liou, J.C.P.
Mass-balance calculations for leak detection have been shown as effective as a leading software system, in a comparison based on a major Canadian crude-oil pipeline. The calculations and NovaCorp`s Leakstop software each detected 4% (approximately) or greater leaks on Interprovincial Pipe Line (IPL) Inc.`s Norman Wells pipeline. Insufficient data exist to assess performances of the two methods for leaks smaller than 4%. Pipeline leak detection using such software-based systems are common. Their effectiveness is measured by how small and how quickly a leak can be detected. Algorithms used and measurement uncertainties determine leak detectability.
Measuring the performance of visual to auditory information conversion.
Tan, Shern Shiou; Maul, Tomás Henrique Bode; Mennie, Neil Russell
2013-01-01
Visual to auditory conversion systems have been in existence for several decades. Besides being among the front runners in providing visual capabilities to blind users, the auditory cues generated from image sonification systems are still easier to learn and adapt to compared to other similar techniques. Other advantages include low cost, easy customizability, and universality. However, every system developed so far has its own set of strengths and weaknesses. In order to improve these systems further, we propose an automated and quantitative method to measure the performance of such systems. With these quantitative measurements, it is possible to gauge the relative strengths and weaknesses of different systems and rank the systems accordingly. Performance is measured by both the interpretability and also the information preservation of visual to auditory conversions. Interpretability is measured by computing the correlation of inter image distance (IID) and inter sound distance (ISD) whereas the information preservation is computed by applying Information Theory to measure the entropy of both visual and corresponding auditory signals. These measurements provide a basis and some insights on how the systems work. With an automated interpretability measure as a standard, more image sonification systems can be developed, compared, and then improved. Even though the measure does not test systems as thoroughly as carefully designed psychological experiments, a quantitative measurement like the one proposed here can compare systems to a certain degree without incurring much cost. Underlying this research is the hope that a major breakthrough in image sonification systems will allow blind users to cost effectively regain enough visual functions to allow them to lead secure and productive lives.
Exploratory study on performance measures as indicators of IS effectiveness
NASA Technical Reports Server (NTRS)
Bishop, Peter C.; Yoes, Cissy
1992-01-01
The Information Systems Directorate at JSC/NASA has undertaken the reevaluation of its performance measures process and measures. Under the direction of a quality approach it is essential to identify an external perspective of how well an organization is performing. This study was conducted with two major objectives: (1) survey and summarize the academic literature on performance measures as indicators of information systems (IS) effectiveness; and (2) survey organizations for their experience in measuring for IS effectiveness. Four approaches to measuring the effectiveness of IS performance were identified: (1) listen to the customer for the things they need; (2) align with corporate goals; (3) benchmark against well-respected organizations; and (4) ask yourself what critical factors lead to success. The list of known methods for soliciting customer feedback are as follows: (1) executive visit; (2) survey, interview, and focus group; (3) complaints and compliments; and (4) service level agreements. A common set of characteristics that satisfy customers was identified from the literature. The list includes elements such as the following: accuracy, timeliness, relevance, understandability, reliability, and completeness. Future research in this topic area should prove beneficial to determine the metrics for external validity.
McCalman, Janya; Jongen, Crystal; Bainbridge, Roxanne
2017-05-12
Healthcare organisations serve clients from diverse Indigenous and other ethnic and racial groups on a daily basis, and require appropriate client-centred systems and services for provision of optimal healthcare. Despite advocacy for systems-level approaches to cultural competence, the primary focus in the literature remains on competency strategies aimed at health promotion initiatives, workforce development and student education. This paper aims to bridge the gap in available evidence about systems approaches to cultural competence by systematically mapping key concepts, types of evidence, and gaps in research. A literature search was completed as part of a larger systematic search of evaluations and measures of cultural competence interventions in health care in Canada, the United States, Australia and New Zealand. Seventeen peer-reviewed databases, 13 websites and clearinghouses, and 11 literature reviews were searched from 2002 to 2015. Overall, 109 studies were found, with 15 evaluating systems-level interventions or describing measurements. Thematic analysis was used to identify key implementation principles, intervention strategies and outcomes reported. Twelve intervention and three measurement studies met our inclusion criteria. Key principles for implementing systems approaches were: user engagement, organisational readiness, and delivery across multiple sites. Two key types of intervention strategies to embed cultural competence within health systems were: audit and quality improvement approaches and service-level policies or strategies. Outcomes were found for organisational systems, the client/practitioner encounter, health, and at national policy level. We could not determine the overall effectiveness of systems-level interventions to reform health systems because interventions were context-specific, there were too few comparative studies and studies did not use the same outcome measures. However, examined together, the intervention and measurement principles, strategies and outcomes provide a preliminary framework for implementation and evaluation of systems-level interventions to improve cultural competence. Identified gaps in the literature included a need for cost and effectiveness studies of systems approaches and explication of the effects of cultural competence on client experience. Further research is needed to explore the extent to which cultural competence improves health outcomes and reduces ethnic and racially-based healthcare disparities.
Counterfactual Measurements and the Quantum Zeno Effect
NASA Astrophysics Data System (ADS)
Russo, Onofrio; Jiang, Liang
2014-03-01
The apparent paradoxical paradigm of an interaction free measurement (counterfactual measurement) of the presence of a classical or quantum object without any scattering or absorption of photons is considered in light of the quantum Zeno effect. From one perspective, the counterfactual measurement in principle is consistent with minimizing the interaction between the object and the photon. However, the quantum Zeno effect mandates that repeated interactions with photons (although weakly coupled) are required and necessary to inhibit the coherent evolution of the state of the system. We consider and appraise these seemingly conflicting concepts.
Designing Teacher Evaluation Systems: New Guidance from the Measures of Effective Teaching Project
ERIC Educational Resources Information Center
Kane, Thomas J., Ed.; Kerr, Kerri A., Ed.; Pianta, Robert C., Ed.
2014-01-01
What is effective teaching? It is not enough to say "I know it when I see it"--not when we are expecting so much more from students and teachers than in the past. To help teachers achieve greater success with their students we need new and better ways to identify and develop effective teaching. The Measures of Effective Teaching (MET)…
2015-09-01
SOA Service-Oriented Architecture SOTM Satellite Communications-on-the-Move SoS System of Systems SwCIs Software Criticality Indices TPM Technical...into the C2 system. To manage stakeholders’ expectations, there is a need to evaluate the effectiveness of the deployed C2 system having implemented ...the C2 system. However, there is a need to recognize the limitations and constraints on the land battlefield to implement these requirements. There
Study on application of adaptive fuzzy control and neural network in the automatic leveling system
NASA Astrophysics Data System (ADS)
Xu, Xiping; Zhao, Zizhao; Lan, Weiyong; Sha, Lei; Qian, Cheng
2015-04-01
This paper discusses the adaptive fuzzy control and neural network BP algorithm in large flat automatic leveling control system application. The purpose is to develop a measurement system with a flat quick leveling, Make the installation on the leveling system of measurement with tablet, to be able to achieve a level in precision measurement work quickly, improve the efficiency of the precision measurement. This paper focuses on the automatic leveling system analysis based on fuzzy controller, Use of the method of combining fuzzy controller and BP neural network, using BP algorithm improve the experience rules .Construct an adaptive fuzzy control system. Meanwhile the learning rate of the BP algorithm has also been run-rate adjusted to accelerate convergence. The simulation results show that the proposed control method can effectively improve the leveling precision of automatic leveling system and shorten the time of leveling.
Direct measurement of weakly nonequilibrium system entropy is consistent with Gibbs–Shannon form
2017-01-01
Stochastic thermodynamics extends classical thermodynamics to small systems in contact with one or more heat baths. It can account for the effects of thermal fluctuations and describe systems far from thermodynamic equilibrium. A basic assumption is that the expression for Shannon entropy is the appropriate description for the entropy of a nonequilibrium system in such a setting. Here we measure experimentally this function in a system that is in local but not global equilibrium. Our system is a micron-scale colloidal particle in water, in a virtual double-well potential created by a feedback trap. We measure the work to erase a fraction of a bit of information and show that it is bounded by the Shannon entropy for a two-state system. Further, by measuring directly the reversibility of slow protocols, we can distinguish unambiguously between protocols that can and cannot reach the expected thermodynamic bounds. PMID:29073017
NASA Astrophysics Data System (ADS)
Ferger, R.; Machens, U.
1985-05-01
A one-family house was equipped with a combined solar and wind energy system plus a night storage heater to measure the seasonal complementary contribution of wind and solar energy to energy demand. Project implementation, problems encountered and modifications to the initial system are described. Meteorological and operational data and house consumption data were recorded on computer-based measuring system. Data on the combined effects of and interdependence between solar collector and wind energy converter are discussed.
Skydan, Oleksandr A; Lilley, Francis; Lalor, Michael J; Burton, David R
2003-09-10
We present an investigation into the phase errors that occur in fringe pattern analysis that are caused by quantization effects. When acquisition devices with a limited value of camera bit depth are used, there are a limited number of quantization levels available to record the signal. This may adversely affect the recorded signal and adds a potential source of instrumental error to the measurement system. Quantization effects also determine the accuracy that may be achieved by acquisition devices in a measurement system. We used the Fourier fringe analysis measurement technique. However, the principles can be applied equally well for other phase measuring techniques to yield a phase error distribution that is caused by the camera bit depth.
Dynamic gas temperature measurement system
NASA Technical Reports Server (NTRS)
Elmore, D. L.; Robinson, W. W.; Watkins, W. B.
1983-01-01
A gas temperature measurement system with compensated frequency response of 1 KHz and capability to operate in the exhaust of a gas turbine combustor was developed. Environmental guidelines for this measurement are presented, followed by a preliminary design of the selected measurement method. Transient thermal conduction effects were identified as important; a preliminary finite-element conduction model quantified the errors expected by neglecting conduction. A compensation method was developed to account for effects of conduction and convection. This method was verified in analog electrical simulations, and used to compensate dynamic temperature data from a laboratory combustor and a gas turbine engine. Detailed data compensations are presented. Analysis of error sources in the method were done to derive confidence levels for the compensated data.
NASA Astrophysics Data System (ADS)
Zhao, Chun-yan; Li, Xin; Wei, Wei; Zheng, Xiao-bing
2016-10-01
With the progress of quantitative remote sensing, the acquisition of surface BRDF becomes more and more important. In order to improve the accuracy of the surface BRDF measurements, a VNIR-SWIR Bidirectional Reflectance Automatic Measurement System, which was developed by Hefei Institutes of Physical Science (HIPS), is introduced that allows in situ measurements of hyperspectral bidirectional reflectance data. Hyperspectral bidirectional reflectance distribution function data sets taken with the BRDF automatic measurement system nominally cover the spectral range between 390 and 2390 nm in 971 bands. In July 2007, September 2008, June 2011, we acquired a series of the BRDF data covered Dunhuang radiometric calibration test site in terms of the BRDF measurement system. We have not obtained such comprehensive and accurate data as they are, since 1990s when the site was built up. These data are applied to calibration for FY-2 and other satellites sensors. Field BRDF data of a Dunhuang site surface reveal a strong spectral variability. An anisotropy factor (ANIF), defined as the ratio between the directional reflectance and nadir reflectance over the hemisphere, is introduced as a surrogate measurement for the extent of spectral BRDF effects. The ANIF data show a very high correlation with the solar zenith angle due to multiple scattering effects over a desert site. Since surface geometry, multiple scattering, and BRDF effects are related, these findings may help to derive BRDF model parameters from the in-situ BRDF measurement remotely sensed hyperspectral data sets.
Dillman, Jonathan R; Chen, Shigao; Davenport, Matthew S; Zhao, Heng; Urban, Matthew W; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L
2015-03-01
There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. To assess the repeatability and reproducibility of superficial shear wave speed measurements acquired from elasticity phantoms at varying imaging depths using three imaging methods, two US systems and multiple operators. Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems Inc. (Norfolk, VA) were utilized for our investigation. Institution No. 1 used an Acuson S3000 US system (Siemens Medical Solutions USA, Malvern, PA) and three shear wave imaging method/transducer combinations, while institution No. 2 used an Aixplorer US system (SuperSonic Imagine, Bothell, WA) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0 cm, 2.5 cm and 4.0 cm) by four operators at each institution. Student's t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single-measure intra-class correlation coefficients (ICCs) and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (P = 0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (P > 0.05). The coefficients of variation were low (0.5-6.8%), and interoperator agreement was near-perfect (ICCs ≥ 0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (P < 0.0001). Superficial shear wave speed measurements in elasticity phantoms demonstrate minimal variability across imaging method/transducer combinations, imaging depths and operators. The exact clinical significance of this variation is uncertain and may change according to organ and specific disease state.
Dillman, Jonathan R.; Chen, Shigao; Davenport, Matthew S.; Zhao, Heng; Urban, Matthew W.; Song, Pengfei; Watcharotone, Kuanwong; Carson, Paul L.
2014-01-01
Background There is a paucity of data available regarding the repeatability and reproducibility of superficial shear wave speed (SWS) measurements at imaging depths relevant to the pediatric population. Purpose To assess the repeatability and reproducibility of superficial shear wave speed (SWS) measurements acquired from elasticity phantoms at varying imaging depths using three different imaging methods, two different ultrasound systems, and multiple operators. Methods and Materials Soft and hard elasticity phantoms manufactured by Computerized Imaging Reference Systems, Inc. (Norfolk, VA) were utilized for our investigation. Institution #1 used an Acuson S3000 ultrasound system (Siemens Medical Solutions USA, Inc.) and three different shear wave imaging method/transducer combinations, while institution #2 used an Aixplorer ultrasound system (Supersonic Imagine) and two different transducers. Ten stiffness measurements were acquired from each phantom at three depths (1.0, 2.5, and 4.0 cm) by four operators at each institution. Student’s t-test was used to compare SWS measurements between imaging techniques, while SWS measurement agreement was assessed with two-way random effects single measure intra-class correlation coefficients and coefficients of variation. Mixed model regression analysis determined the effect of predictor variables on SWS measurements. Results For the soft phantom, the average of mean SWS measurements across the various imaging methods and depths was 0.84 ± 0.04 m/s (mean ± standard deviation) for the Acuson S3000 system and 0.90 ± 0.02 m/s for the Aixplorer system (p=0.003). For the hard phantom, the average of mean SWS measurements across the various imaging methods and depths was 2.14 ± 0.08 m/s for the Acuson S3000 system and 2.07 ± 0.03 m/s Aixplorer system (p>0.05). The coefficients of variation were low (0.5–6.8%), and inter-operator agreement was near-perfect (ICCs ≥0.99). Shear wave imaging method and imaging depth significantly affected measured SWS (p<0.0001). Conclusions Superficial SWS measurements in elasticity phantoms demonstrate minimal variability across imaging method/transducer combinations, imaging depths, and between operators. The exact clinical significance of this variability is uncertain and may vary by organ and specific disease state. PMID:25249389
Holey, Liz A; Dixon, John; Selfe, James
2011-09-01
The purpose of this study was to measure effects of connective tissue massage (CTM) on the autonomic nervous system using thermography and physiological measurements. A repeated-measures design was used. The setting was a university laboratory. Skin temperature at the site of massage, blood pressure, heart rate, and dorsal foot temperature were measured in 8 healthy participants before CTM, immediately after, and at 15-minute intervals for 1 hour. The effect of CTM on skin temperature was statistically significant, P = .011. Post hoc pairwise comparisons revealed that the 15-, 30-, 45-, and 60-minute data all differed significantly from the pre-CTM data (all P < .05) and also from the immediately post-CTM data (all P < .05). For diastolic blood pressure, the main analysis of variance showed a statistical significance at P = .062. For other variables, there was no evidence for an effect. Evidence was seen of some effects of CTM on autonomic function. This is information that will increase our knowledge of how CTM affects the autonomic nervous system. Copyright © 2011 National University of Health Sciences. Published by Mosby, Inc. All rights reserved.
Defining pharmaceutical systems strengthening: concepts to enable measurement.
Hafner, Tamara; Walkowiak, Helena; Lee, David; Aboagye-Nyame, Francis
2017-05-01
Pharmaceutical products are indispensable for improving health outcomes. An extensive body of work on access to and use of medicines has resulted in an assortment of tools measuring various elements of pharmaceutical systems. Until now however, there has been little attempt to conceptualize a pharmaceutical system as an entity and define its strengthening in a way that allows for measuring systems strengthening. The narrow focus of available tools limits their value in ascertaining which interventions result in stronger, more resilient systems. We sought to address this shortcoming by revisiting the current definitions, frameworks and assessment tools related to pharmaceutical systems. We conducted a comprehensive literature review and consulted with select pharmaceutical experts. On the basis of our review, we propose that a pharmaceutical system consists of all structures, people, resources, processes, and their interactions within the broader health system that aim to ensure equitable and timely access to safe, effective, quality pharmaceutical products and related services that promote their appropriate and cost-effective use to improve health outcomes. We further propose that pharmaceutical systems strengthening is the process of identifying and implementing strategies and actions that achieve coordinated and sustainable improvements in the critical components of a pharmaceutical system to make it more responsive and resilient and to enhance its performance for achieving better health outcomes. Finally, we established that, in addition to system performance and resilience, seven components of the pharmaceutical system are critical for measuring pharmaceutical systems strengthening: pharmaceutical products and related services; policy, laws and governance; regulatory systems; innovation, research and development, manufacturing, and trade; financing; human resources; and information. This work adds clarity to the concept of pharmaceutical systems and their strengthening by proposing holistic definitions on the basis of systems thinking. It provides a practical starting point for measuring the progress of pharmaceutical systems strengthening. © The Author 2016. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.
Groene, Oliver; Botje, Daan; Suñol, Rosa; Lopez, Maria Andrée; Wagner, Cordula
2013-10-01
Health-care providers invest substantial resources to establish and implement hospital quality management systems. Nevertheless, few tools are available to assess implementation efforts and their effect on quality and safety outcomes. This review aims to (i) identify instruments to assess the implementation of hospital quality management systems, (ii) describe their measurement properties and (iii) assess the effects of quality management on quality improvement and quality of care outcomes. We performed a systematic literature search from 1990 to 2011 in PubMed, CINAHL, EMBASE, Cochrane Library and Web of Science. In addition, we used snowball strategies, screened the reference lists of eligible papers, reviewed grey literature and contacted experts in the field. and data extraction Two reviewers screened eligible papers based on pre-defined inclusion and exclusion criteria and all authors extracted data. Eligible papers are described in terms of general characteristics (settings, type and level of respondents, mode of data collection), methodological properties (sampling strategy, item derivation, conceptualization of quality management, assessment of reliability and validity, scoring) and application/implementation (accounting for context, organizational adaptations, sensitivity to change, deployment and effect size). Eighteen papers were deemed eligible for inclusion. While some common domains emerged in measurement conceptualization, substantial differences in scope persist. The instruments' measurement properties were insufficiently described and only few instruments assessed links between the implementation of quality management systems (QMS) and improvement strategies or outcomes. There is currently no well-established measure to assess the implementation and effectiveness of quality management systems. Future research should address this gap.
Using the Tax System to Promote Physical Activity: Critical Analysis of Canadian Initiatives
Larre, Tamara; Sauder, JoAnne
2011-01-01
In Canada, tax incentives have been recently introduced to promote physical activity and reduce rates of obesity. The most prominent of these is the federal government's Children's Fitness Tax Credit, which came into effect in 2007. We critically assess the potential benefits and limitations of using tax measures to promote physical activity. Careful design could make these measures more effective, but any tax-based measures have inherent limitations, and the costs of such programs are substantial. Therefore, it is important to consider whether public funds are better spent on other strategies that could instead provide direct public funding to address environmental and systemic factors. PMID:21680912
Using the tax system to promote physical activity: critical analysis of Canadian initiatives.
von Tigerstrom, Barbara; Larre, Tamara; Sauder, Joanne
2011-08-01
In Canada, tax incentives have been recently introduced to promote physical activity and reduce rates of obesity. The most prominent of these is the federal government's Children's Fitness Tax Credit, which came into effect in 2007. We critically assess the potential benefits and limitations of using tax measures to promote physical activity. Careful design could make these measures more effective, but any tax-based measures have inherent limitations, and the costs of such programs are substantial. Therefore, it is important to consider whether public funds are better spent on other strategies that could instead provide direct public funding to address environmental and systemic factors.
Development of a Novel System to Measure a Clearance of a Passenger Platform
NASA Astrophysics Data System (ADS)
Shimizu, M.; Oizumi, J.; Matsuoka, R.; Takeda, H.; Okukura, H.; Ooya, A.; Koike, A.
2016-06-01
Clearances of a passenger platform at a railway station should be appropriately maintained for safety of both trains and passengers. In most Japanese railways clearances between a platform and a train car is measured precisely once or twice a year. Because current measurement systems operate on a track, the closure of the track is unavoidable. Since the procedure of the closure of a track is time-consuming and bothersome, we decided to develop a new system to measure clearances without the closure of a track. A new system is required to work on a platform and the required measurement accuracy is less than several millimetres. We have adopted a 3D laser scanner and stop-and-go operation for a new system. The current systems on a track measure clearances continuously at walking speed, while our system on a platform measures clearances at approximately ten metres intervals. The scanner controlled by a PC acquires a set of point data at each measuring station. Edge points of the platform, top and side points of two rails are detected from the acquired point data. Finally clearances of the platform are calculated by using the detected feature points of the platform and the rails. The results of an experiment using a prototype of our system show that the measurement accuracy by our system would be satisfactory, but our system would take more time than the current systems. Since our system requires no closure of a track, we conclude that our system would be convenient and effective.
Donovan, Preston; Chehreghanianzabi, Yasaman; Rathinam, Muruhan; Zustiak, Silviya Petrova
2016-01-01
The study of diffusion in macromolecular solutions is important in many biomedical applications such as separations, drug delivery, and cell encapsulation, and key for many biological processes such as protein assembly and interstitial transport. Not surprisingly, multiple models for the a-priori prediction of diffusion in macromolecular environments have been proposed. However, most models include parameters that are not readily measurable, are specific to the polymer-solute-solvent system, or are fitted and do not have a physical meaning. Here, for the first time, we develop a homogenization theory framework for the prediction of effective solute diffusivity in macromolecular environments based on physical parameters that are easily measurable and not specific to the macromolecule-solute-solvent system. Homogenization theory is useful for situations where knowledge of fine-scale parameters is used to predict bulk system behavior. As a first approximation, we focus on a model where the solute is subjected to obstructed diffusion via stationary spherical obstacles. We find that the homogenization theory results agree well with computationally more expensive Monte Carlo simulations. Moreover, the homogenization theory agrees with effective diffusivities of a solute in dilute and semi-dilute polymer solutions measured using fluorescence correlation spectroscopy. Lastly, we provide a mathematical formula for the effective diffusivity in terms of a non-dimensional and easily measurable geometric system parameter.
Izquierdo, F Aparicio; Ramírez, B Arenas; McWilliams, J M Mira; Ayuso, J Páez
2011-05-01
In this work we have used ARIMA time series models to analyse the contribution of the penalty point system, the most important legislative measure for driving licences, in reducing the number of fatalities over 24h on the roads in Spain during the study period (January 1995 to June 2009). In addition, because of this long period of analysis, other control variables were introduced to model the enactment of the Reform of the Penal Code in December 2007, together with other more specific effects needed to fit the model correctly. The ARIMA intervention models methodology combines the basic features of specific times series models: it controls the trend and seasonal variation in data that is present when modelling the structure through autoregressive and moving average parameters and allows for inserting step or impulse input variables for checking and evaluating the effects of deterministic measures, such as legislative changes which are the object of study in this work. This paper analyses the surveillance and control measures introduced in the periods before and after the implementation of the penalty point system and helps to partly explain its apparent endurance over time. The results show that the introduction of the penalty point system in Spain had a very positive effect in reducing the number of fatalities (over 24h) on the road, and that this effect has endured up to the present time. This success may be due to the continuing increase in surveillance measures and fines as well the significantly growing interest shown by the news media in road safety since the measures were introduced. All this has led to positive changes in driver behaviour. It is, therefore, a combination of three factors: the penalty point system, the gradual stepping up of surveillance measures and sanctions, and the publicity given to road safety issues in the mass media would appear to be the key to success. The absence of any of these three factors would have predictably led to a far less positive evolution of the accident rate on Spanish roads. Copyright © 2010 Elsevier Ltd. All rights reserved.
Effective mass and spin susceptibility of dilute two-dimensional holes ion GaAs.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiu, Y-T.; Padmanabhan, M.; Gokmen, T.
2011-10-31
We report effective hole mass (m*) measurements through analyzing the temperature dependence of Shubnikov-de Haas oscillations in dilute (density p {approx} 7 x 10{sup 10} cm{sup -2}, r{sub s} {approx} 6) two-dimensional (2D) hole systems confined to a 20-nm-wide, (311)A GaAs quantum well. The holes in this system occupy two nearly degenerate spin subbands whose m* we measure to be {approx}0.2 (in units of the free electron mass). Despite the relatively large r{sub s} in our 2D system, the measured m* is in reasonably good agreement with the results of our energy band calculations, which do not take interactions intomore » account. We then apply a sufficiently strong parallel magnetic field to fully depopulate one of the spin subbands, and measure m* for the populated subband. We find that this latter m* is close to the m* we measure in the absence of the parallel field. We also deduce the spin susceptibility of the 2D hole system from the depopulation field, and we conclude that the susceptibility is enhanced by about 50% relative to the value expected from the band calculations.« less
Fiber-Optic Current Sensor Validation with Triggered Lightning Measurements
NASA Technical Reports Server (NTRS)
Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.; Mata, Carlos T.; Mata, Angel G.; Snyder, Gary P.
2013-01-01
A fiber optic current sensor based on the Faraday Effect is developed that is highly suitable for aircraft installation and can measure total current enclosed in a fiber loop down to DC. Other attributes include being small, light-weight, non-conducting, safe from electromagnetic interference, and free of hysteresis and saturation. The Faraday Effect causes light polarization to rotate when exposed to a magnetic field in the direction of light propagation. Measuring the induced light polarization rotation in fiber loops yields the total current enclosed. Two sensor systems were constructed and installed at Camp Blanding, Florida, measuring rocket-triggered lightning. The systems were similar in design but with different laser wavelengths, sensitivities and ranges. Results are compared to a shunt resistor as reference. The 850nm wavelength system tested in summer 2011 showed good result comparison early. However, later results showed gradual amplitude increase with time, attributed to corroded connections affecting the 50-ohm output termination. The 1550nm system also yielded good results in the summer 2012. The successful measurements demonstrate the fiber optic sensor's accuracies in capturing real lightning currents, and represent an important step toward future aircraft installation.
Progress on the FIReTIP Diagnostic on NSTX-U
NASA Astrophysics Data System (ADS)
Scott, Evan; Barchfeld, Robert; Riemenschneider, Paul; Muscatello, Chris; Sohrabi, Mohammad; Domier, Calvin; Ren, Yang; Kaita, Robert; Luhmann, Neville, Jr.; NSTX-U Team
2016-10-01
The Far-infrared Tangential Interferometer/Polarimeter (FIReTIP) system on NSTX-U at the PPPL aims to provide robust, line-averaged electron density measurements. The system consists of three optically-pumped 119 µm methanol lasers, one of which can be tuned via Stark broadening, allowing for uniquely high intermediate frequencies and time resolutions. One of the major goals of FIReTIP is to incorporate it into the NSTX-U plasma control system (PCS) for real-time plasma density feedback control. The front-end optics mounted to Bay G, which shape and position the beam going into the plasma, and internal retroreflector located near Bay B, which facilitates double-pass measurements, are hard-mounted to the NSTX-U vacuum vessel. Because interferometric density measurements are sensitive to vibrational effects, FIReTIP has been upgraded to a two-color interferometer system with the inclusion of a 633 nm laser interferometer for the direct measurement of vibrations and a field programmable gate array (FPGA) for the subsequent subtraction of vibrational effects from the density measurement in real-time. This work is supported by the U.S. Department of Energy Grant DE-FG02-99ER54518.
Development of haptic system for surgical robot
NASA Astrophysics Data System (ADS)
Gang, Han Gyeol; Park, Jiong Min; Choi, Seung-Bok; Sohn, Jung Woo
2017-04-01
In this paper, a new type of haptic system for surgical robot application is proposed and its performances are evaluated experimentally. The proposed haptic system consists of an effective master device and a precision slave robot. The master device has 3-DOF rotational motion as same as human wrist motion. It has lightweight structure with a gyro sensor and three small-sized MR brakes for position measurement and repulsive torque generation, respectively. The slave robot has 3-DOF rotational motion using servomotors, five bar linkage and a torque sensor is used to measure resistive torque. It has been experimentally demonstrated that the proposed haptic system has good performances on tracking control of desired position and repulsive torque. It can be concluded that the proposed haptic system can be effectively applied to the surgical robot system in real field.
Temperature Distribution Measurement of The Wing Surface under Icing Conditions
NASA Astrophysics Data System (ADS)
Isokawa, Hiroshi; Miyazaki, Takeshi; Kimura, Shigeo; Sakaue, Hirotaka; Morita, Katsuaki; Japan Aerospace Exploration Agency Collaboration; Univ of Notre Dame Collaboration; Kanagawa Institute of Technology Collaboration; Univ of Electro-(UEC) Team, Comm
2016-11-01
De- or anti-icing system of an aircraft is necessary for a safe flight operation. Icing is a phenomenon which is caused by a collision of supercooled water frozen to an object. For the in-flight icing, it may cause a change in the wing cross section that causes stall, and in the worst case, the aircraft would fall. Therefore it is important to know the surface temperature of the wing for de- or anti-icing system. In aerospace field, temperature-sensitive paint (TSP) has been widely used for obtaining the surface temperature distribution on a testing article. The luminescent image from the TSP can be related to the temperature distribution. (TSP measurement system) In icing wind tunnel, we measured the surface temperature distribution of the wing model using the TSP measurement system. The effect of icing conditions on the TSP measurement system is discussed.
Pulpal thermal responses to an erbium,chromium: YSGG pulsed laser hydrokinetic system.
Rizoiu, I; Kohanghadosh, F; Kimmel, A I; Eversole, L R
1998-08-01
Laser systems are known to raise pulpal temperatures when applied to tooth surfaces. Dental biocalcified tissues can be cut with an erbium,chromium:yttrium-scandium-gallium-garnet laser-powered hydrokinetic system. This device is effective for caries removal and cavity preparation in vitro. Pulpal monitoring of temperature changes during hard tissue cutting by a hydrokinetic system have not been reported. This study compared the effects of hydrokinetic system, dry bur, and wet bur tooth cutting on pulpal temperature. In vivo thermocouple intrapulpal measurements were made on cuspid teeth in anesthetized beagle dogs. In vitro measurements were made on extracted human molar teeth preserved in high-salt solution and later rinsed in phosphate-buffered saline (pH 7.4) to simulate in vivo conditions. The hydrokinetic system was compared with conventional air-turbine-powered bur cutting. The hydrokinetic system cuts and bur preparations were randomly made on the buccal surfaces at the cervical one third of the crown and extended until exposure of the pulp was confirmed clinically. Pulpal temperatures associated with the hydrokinetic system either showed no change or decreased by up to 2 degrees C. Wet bur preparations resulted in a 3 degrees to 4 degrees C rise. With dry bur preparations, a 14 degrees C rise in temperature was recorded. Under the conditions of this study, the erbium,chromium:yttrium-scandium-gallium-garnet laser-powered hydrokinetic system, when used for cavity preparation, had no apparent adverse thermal effect as measured in the pulp space.
[Benchmarking of performance of Mexican states with effective coverage].
Lozano, Rafael; Soliz, Patricia; Gakidou, Emmanuela; Abbott-Klafter, Jesse; Feehan, Dennis M; Vidal, Cecilia; Ortiz, Juan Pablo; Murray, Christopher J L
2007-01-01
Benchmarking of the performance of states, provinces, or districts in a decentralised health system is important for fostering of accountability, monitoring of progress, identification of determinants of success and failure, and creation of a culture of evidence. The Mexican Ministry of Health has, since 2001, used a benchmarking approach based on the World Health Organization (WHO) concept of effective coverage of an intervention, which is defined as the proportion of potential health gain that could be delivered by the health system to that which is actually delivered. Using data collection systems, including state representative examination surveys, vital registration, and hospital discharge registries, we have monitored the delivery of 14 interventions for 2005-06. Overall effective coverage ranges from 54.0% in Chiapas, a poor state, to 65.1% in the Federal District. Effective coverage for maternal and child health interventions is substantially higher than that for interventions that target other health problems. Effective coverage for the lowest wealth quintile is 52% compared with 61% for the highest quintile. Effective coverage is closely related to public-health spending per head across states; this relation is stronger for interventions that are not related to maternal and child health than those for maternal and child health. Considerable variation also exists in effective coverage at similar amounts of spending. We discuss the implications of these issues for the further development of the Mexican health-information system. Benchmarking of performance by measuring effective coverage encourages decision-makers to focus on quality service provision, not only service availability. The effective coverage calculation is an important device for health-system stewardship. In adopting this approach, other countries should select interventions to be measured on the basis of the criteria of affordability, effect on population health, effect on health inequalities, and capacity to measure the effects of the intervention. The national institutions undertaking this benchmarking must have the mandate, skills, resources, and independence to succeed.
Benchmarking of performance of Mexican states with effective coverage.
Lozano, Rafael; Soliz, Patricia; Gakidou, Emmanuela; Abbott-Klafter, Jesse; Feehan, Dennis M; Vidal, Cecilia; Ortiz, Juan Pablo; Murray, Christopher J L
2006-11-11
Benchmarking of the performance of states, provinces, or districts in a decentralised health system is important for fostering of accountability, monitoring of progress, identification of determinants of success and failure, and creation of a culture of evidence. The Mexican Ministry of Health has, since 2001, used a benchmarking approach based on the WHO concept of effective coverage of an intervention, which is defined as the proportion of potential health gain that could be delivered by the health system to that which is actually delivered. Using data collection systems, including state representative examination surveys, vital registration, and hospital discharge registries, we have monitored the delivery of 14 interventions for 2005-06. Overall effective coverage ranges from 54.0% in Chiapas, a poor state, to 65.1% in the Federal District. Effective coverage for maternal and child health interventions is substantially higher than that for interventions that target other health problems. Effective coverage for the lowest wealth quintile is 52% compared with 61% for the highest quintile. Effective coverage is closely related to public-health spending per head across states; this relation is stronger for interventions that are not related to maternal and child health than those for maternal and child health. Considerable variation also exists in effective coverage at similar amounts of spending. We discuss the implications of these issues for the further development of the Mexican health-information system. Benchmarking of performance by measuring effective coverage encourages decision-makers to focus on quality service provision, not only service availability. The effective coverage calculation is an important device for health-system stewardship. In adopting this approach, other countries should select interventions to be measured on the basis of the criteria of affordability, effect on population health, effect on health inequalities, and capacity to measure the effects of the intervention. The national institutions undertaking this benchmarking must have the mandate, skills, resources, and independence to succeed.
DOT National Transportation Integrated Search
2016-10-01
The 84th Texas Legislature passed House Bill (HB) 790 directing the Texas A&M Transportation Institute (TTI) to perform a study on the implementation and effectiveness of sound mitigation measures on the state highway system and certain toll roads an...
LARVAL SALAMANDER GROWTH RESPONDS TO ENRICHMENT OF A NUTRIENT POOR HEADWATER STREAM
While many studies have measured effects of nutrient enrichment on higher trophic levels in grazing food webs, few such studies exist for detritus-based systems. We measured effects of nitrogen and phosphorus addition on growth of larval Eruycea wilderae in a heterotrophic head...
Assessing Gaussian Assumption of PMU Measurement Error Using Field Data
Wang, Shaobu; Zhao, Junbo; Huang, Zhenyu; ...
2017-10-13
Gaussian PMU measurement error has been assumed for many power system applications, such as state estimation, oscillatory modes monitoring, voltage stability analysis, to cite a few. This letter proposes a simple yet effective approach to assess this assumption by using the stability property of a probability distribution and the concept of redundant measurement. Extensive results using field PMU data from WECC system reveal that the Gaussian assumption is questionable.
Comparative performance of HgCdTe photodiodes for heterodyne application
NASA Technical Reports Server (NTRS)
Kowitz, H. R.
1980-01-01
The use of photodiodes as optical photomixers in laser heterodyne spectroscopy systems is discussed. The quantum efficiency of the photodiodes is reported with the emphasis on its effect on the system's signal to noise ratio. The measurement techniques used to determine photodiode dc and heterodyne quantum efficiencies are described. The theory behind the measurements as well as actual measurements data for two HgCdTe photodiodes are presented.
Coherent laser radar at 2 microns using solid-state lasers
NASA Technical Reports Server (NTRS)
Henderson, Sammy W.; Suni, Paul J. M.; Hale, Charley P.; Hannon, Stephen M.; Magee, James R.; Bruns, Dale L.; Yuen, Eric H.
1993-01-01
Coherent laser radar systems using 2-micron Tm- and Tm, Ho-doped solid-state lasers are useful for the remote range-resolved measurement of atmospheric winds, aerosol backscatter, and DIAL measurements of atmospheric water vapor and CO2 concentrations. Recent measurements made with a 2-micron coherent laser radar system, advances in the laser technology, and atmospheric propagation effects on 2-micron coherent lidar performance are described.
Zhang, Wei; Ma, Hong; Yang, Simon X.
2016-01-01
In this research, an improved psychrometer is developed to solve practical issues arising in the relative humidity measurement of challenging drying environments for meat manufacturing in agricultural and agri-food industries. The design in this research focused on the structure of the improved psychrometer, signal conversion, and calculation methods. The experimental results showed the effect of varying psychrometer structure on relative humidity measurement accuracy. An industrial application to dry-cured meat products demonstrated the effective performance of the improved psychrometer being used as a relative humidity measurement sensor in meat-drying rooms. In a drying environment for meat manufacturing, the achieved measurement accuracy for relative humidity using the improved psychrometer was ±0.6%. The system test results showed that the improved psychrometer can provide reliable and long-term stable relative humidity measurements with high accuracy in the drying system of meat products. PMID:26999161
Zhang, Wei; Ma, Hong; Yang, Simon X
2016-03-18
In this research, an improved psychrometer is developed to solve practical issues arising in the relative humidity measurement of challenging drying environments for meat manufacturing in agricultural and agri-food industries. The design in this research focused on the structure of the improved psychrometer, signal conversion, and calculation methods. The experimental results showed the effect of varying psychrometer structure on relative humidity measurement accuracy. An industrial application to dry-cured meat products demonstrated the effective performance of the improved psychrometer being used as a relative humidity measurement sensor in meat-drying rooms. In a drying environment for meat manufacturing, the achieved measurement accuracy for relative humidity using the improved psychrometer was ±0.6%. The system test results showed that the improved psychrometer can provide reliable and long-term stable relative humidity measurements with high accuracy in the drying system of meat products.
Qin, Hua-Peng; Su, Qiong; Khu, Soon-Thiam
2013-01-15
Integrated water environmental management in a rapidly urbanizing area often requires combining social, economic and engineering measures in order to be effective. However, in reality, these measures are often considered independently by different planners, and decisions are made in a hierarchical manner; this has led to problems in environmental pollution control and also an inability to devise innovative solutions due to technological lock-in. In this paper, we use a novel coupled system dynamics and water environmental model (SyDWEM) to simulate the dynamic interactions between the socio-economic system, water infrastructure and receiving water in a rapidly urbanizing catchment in Shenzhen, China. The model is then applied to assess the effects of proposed socio-economic or engineering measures on environmental and development indicators in the catchment for 2011-2020. The results indicate that 1) measures to adjust industry structures have a positive effect on both water quantity and quality in the catchment; 2) measures to increase the labor productivity, the water use efficiency, the water transfer quota or the reclaimed wastewater reuse can alleviate the water shortage, but cannot improve water quality in the river; 3) measures to increase the wastewater treatment rate or the pollutant removal rate can improve water quality in the river, but have no effect on water shortage. Based on the effectiveness of the individual measures, a combination of socio-economic and engineering measures is proposed, which can achieve water environmental sustainability in the study area. Thus, we demonstrate that SyDWEM has the capacity to evaluate the effects of both socio-economic and engineering measures; it also provides a tool for integrated decision making by socio-economic and water infrastructure planners. Copyright © 2012 Elsevier Ltd. All rights reserved.
Measurement and interpretation of crustal deformation rates associated with postglacial rebound
NASA Technical Reports Server (NTRS)
Davis, James L.
1993-01-01
This project involves obtaining Global Positioning System (GPS) measurements in Scandinavia, and using the measurements to estimate the viscosity profile of the Earth's mantle and to correct tide-gage measurements for the rebound effect. Several aspects of this project are reported.
HiPEP Ion Optics System Evaluation Using Gridlets
NASA Technical Reports Server (NTRS)
Willliams, John D.; Farnell, Cody C.; Laufer, D. Mark; Martinez, Rafael A.
2004-01-01
Experimental measurements are presented for sub-scale ion optics systems comprised of 7 and 19 aperture pairs with geometrical features that are similar to the HiPEP ion optics system. Effects of hole diameter and grid-to-grid spacing are presented as functions of applied voltage and beamlet current. Recommendations are made for the beamlet current range where the ion optics system can be safely operated without experiencing direct impingement of high energy ions on the accelerator grid surface. Measurements are also presented of the accelerator grid voltage where beam plasma electrons backstream through the ion optics system. Results of numerical simulations obtained with the ffx code are compared to both the impingement limit and backstreaming measurements. An emphasis is placed on identifying differences between measurements and simulation predictions to highlight areas where more research is needed. Relatively large effects are observed in simulations when the discharge chamber plasma properties and ion optics geometry are varied. Parameters investigated using simulations include the applied voltages, grid spacing, hole-to-hole spacing, doubles-to-singles ratio, plasma potential, and electron temperature; and estimates are provided for the sensitivity of impingement limits on these parameters.
NASA Astrophysics Data System (ADS)
Mazzucchi, Gabriel; Kozlowski, Wojciech; Caballero-Benitez, Santiago F.; Elliott, Thomas J.; Mekhov, Igor B.
2016-02-01
Trapping ultracold atoms in optical lattices enabled numerous breakthroughs uniting several disciplines. Coupling these systems to quantized light leads to a plethora of new phenomena and has opened up a new field of study. Here we introduce an unusual additional source of competition in a many-body strongly correlated system: We prove that quantum backaction of global measurement is able to efficiently compete with intrinsic short-range dynamics of an atomic system. The competition becomes possible due to the ability to change the spatial profile of a global measurement at a microscopic scale comparable to the lattice period without the need of single site addressing. In coherence with a general physical concept, where new competitions typically lead to new phenomena, we demonstrate nontrivial dynamical effects such as large-scale multimode oscillations, long-range entanglement, and correlated tunneling, as well as selective suppression and enhancement of dynamical processes beyond the projective limit of the quantum Zeno effect. We demonstrate both the breakup and protection of strongly interacting fermion pairs by measurement. Such a quantum optical approach introduces into many-body physics novel processes, objects, and methods of quantum engineering, including the design of many-body entangled environments for open systems.
technical backup material for the OCE NEMP PROGRAM, Development of Criteria for Protection of NIKE-X Power Plant and Facilities Electrical Systems Against Nuclear Electromagnetic Pulse Effects, Protective MEASURES. (Author)
Measuring soil and tree temperatures during prescribed fires with thermocouple probes
Stephen S. Sackett; Sally M. Haase
1992-01-01
Soil and cambium temperatures must be known to ascertain certain effects of prescribed fires on trees. Thermocouple-based systems were devised for measuring soil and cambium temperatures during prescribed fires. The systems, which incorporate both commercially available and custom components, perform three basic functions: data collection, data retrieval, and data...
Note: Measurement system for the radiative forcing of greenhouse gases in a laboratory scale.
Kawamura, Yoshiyuki
2016-01-01
The radiative forcing of the greenhouse gases has been studied being based on computational simulations or the observation of the real atmosphere meteorologically. In order to know the greenhouse effect more deeply and to study it from various viewpoints, the study on it in a laboratory scale is important. We have developed a direct measurement system for the infrared back radiation from the carbon dioxide (CO2) gas. The system configuration is similar with that of the practical earth-atmosphere-space system. Using this system, the back radiation from the CO2 gas was directly measured in a laboratory scale, which roughly coincides with meteorologically predicted value.
Does Plant Biomass Manipulation in Static Chambers Affect Nitrous Oxide Emissions from Soils?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collier, Sarah M.; Dean, Andrew P.; Oates, Lawrence G.
One of the most widespread approaches for measurement of greenhouse gas emissions from soils involves the use of static chambers. This method is relatively inexpensive, is easily replicated, and is ideally suited to plot-based experimental systems. Among its limitations is the loss of detection sensitivity with increasing chamber height, which creates challenges for deployment in systems including tall vegetation. It is not always possible to avoid inclusion of plants within chambers or to extend chamber height to fully accommodate plant growth. Thus, in many systems, such as perennial forages and biomass crops, plants growing within static chambers must either bemore » trimmed or folded during lid closure. Currently, data on how different types of biomass manipulation affect measured results is limited. For this study, we compare the effects of cutting vs. folding of biomass on nitrous oxide measurements in switchgrass (Panicum virgatum L.) and alfalfa (Medicago sativa L.) systems. We report only limited evidence of treatment effects during discrete sampling events and little basis for concern that effects may intensify over time as biomass manipulation is repeatedly imposed. However, nonsignificant treatment effects that were consistently present amounted to significant overall trends in three out of the four systems studied. Such minor disparities in flux could amount to considerable quantities over time, suggesting that caution should be exercised when comparing cumulative emission values from studies using different biomass manipulation strategies.« less
Does Plant Biomass Manipulation in Static Chambers Affect Nitrous Oxide Emissions from Soils?
Collier, Sarah M.; Dean, Andrew P.; Oates, Lawrence G.; ...
2016-01-22
One of the most widespread approaches for measurement of greenhouse gas emissions from soils involves the use of static chambers. This method is relatively inexpensive, is easily replicated, and is ideally suited to plot-based experimental systems. Among its limitations is the loss of detection sensitivity with increasing chamber height, which creates challenges for deployment in systems including tall vegetation. It is not always possible to avoid inclusion of plants within chambers or to extend chamber height to fully accommodate plant growth. Thus, in many systems, such as perennial forages and biomass crops, plants growing within static chambers must either bemore » trimmed or folded during lid closure. Currently, data on how different types of biomass manipulation affect measured results is limited. For this study, we compare the effects of cutting vs. folding of biomass on nitrous oxide measurements in switchgrass (Panicum virgatum L.) and alfalfa (Medicago sativa L.) systems. We report only limited evidence of treatment effects during discrete sampling events and little basis for concern that effects may intensify over time as biomass manipulation is repeatedly imposed. However, nonsignificant treatment effects that were consistently present amounted to significant overall trends in three out of the four systems studied. Such minor disparities in flux could amount to considerable quantities over time, suggesting that caution should be exercised when comparing cumulative emission values from studies using different biomass manipulation strategies.« less
Measurement of laser power for photo-triggered drug delivery in vivo
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, R.; Zhang, X. L.; Liu, F.
Thus far, despite many investigations have been carried out for photo-triggered drug delivery systems, most of them suffer from an intrinsic drawback of without real-time monitoring mechanism. Incident intensity of light is a feasible parameter to monitor the drug release profiles. However, it is difficult to measure the incident laser power irradiated onto the photo-triggered carriers in drug delivery systems during in vivo therapy. We design an online measurement method based on the fluorescence intensity ratio (FIR) technique through upconversion nanoparticles. FIR value varies with temperature of sample due to the thermal effect induced by the incident laser, which validatesmore » the laser power measurement. Effects of rare earth doping concentration, as well as experimental conditions including laser spots and wavelengths on the measurement behavior were also investigated.« less
Thermal Remote Sensing and the Thermodynamics of Ecosystems Development
NASA Technical Reports Server (NTRS)
Luvall, Jeffrey C.; Kay, James J.; Fraser, Roydon F.; Goodman, H. Michael (Technical Monitor)
2001-01-01
Thermal remote sensing can provide environmental measuring tools with capabilities for measuring ecosystem development and integrity. Recent advances in applying principles of nonequilibrium thermodynamics to ecology provide fundamental insights into energy partitioning in ecosystems. Ecosystems are nonequilibrium systems, open to material and energy flows, which grow and develop structures and processes to increase energy degradation. More developed terrestrial ecosystems will be more effective at dissipating the solar gradient (degrading its energy content). This can be measured by the effective surface temperature of the ecosystem on a landscape scale. A series of airborne thermal infrared multispectral scanner data were collected from several forested ecosystems ranging from a western US douglas-fir forest to a tropical rain forest in Costa Rica. Also measured were agriculture systems. These data were used to develop measures of ecosystem development and integrity based on surface temperature.
Vibration transfer mobility measurements using maximum length sequences
NASA Astrophysics Data System (ADS)
Singleton, Herbert L.
2005-09-01
Vibration transfer mobility measurements are required under Federal Transit Administration guidelines when developing detailed predictions of ground-borne vibration for rail transit systems. These measurements typically use a large instrumented hammer to generate impulses in the soil. These impulses are measured by an array of accelerometers to characterize the transfer mobility of the ground in a localized area. While effective, these measurements often make use of heavy, custom-engineered equipment to produce the impulse signal. To obtain satisfactory signal-to-noise ratios, it is necessary to generate multiple impulses to generate an average value, but this process involves considerable physical labor in the field. To address these shortcomings, a transfer mobility measurement system utilizing a tactile transducer and maximum length sequences (MLS) was developed. This system uses lightweight off-the-shelf components to significantly reduce the weight and cost of the system. The use of MLS allows for adequate signal-to-noise ratio from the tactile transducer, while minimizing the length of the measurement. Tests of the MLS system show good agreement with the impulse-based method. The combination of the cost savings and reduced weight of this new system facilitates transfer mobility measurements that are less physically demanding, and more economical when compared with current methods.
Characterization of a Low-Cost Multi-Parameter Sensor for Resource Applications: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habte, Aron M; Sengupta, Manajit; Andreas, Afshin M
Low-cost multi-parameter sensing and measurement devices enable cost-effective monitoring of the functional, operational reliability, efficiency, and resiliency of the electrical grid. The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs Inc., deployed Arable Lab's Mark multi-parameter sensor system. The unique suite of system sensors measures the down-welling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. This study describes the shortwave calibration, characteriza-tion, and validation of measurement accuracy of this instrument by comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.
Strain Measurement System Developed for Biaxially Loaded Cruciform Specimens
NASA Technical Reports Server (NTRS)
Krause, David L.
2000-01-01
A new extensometer system developed at the NASA Glenn Research Center at Lewis Field measures test area strains along two orthogonal axes in flat cruciform specimens. This system incorporates standard axial contact extensometers to provide a cost-effective high-precision instrument. The device was validated for use by extensive testing of a stainless steel specimen, with specimen temperatures ranging from room temperature to 1100 F. In-plane loading conditions included several static biaxial load ratios, plus cyclic loadings of various waveform shapes, frequencies, magnitudes, and durations. The extensometer system measurements were compared with strain gauge data at room temperature and with calculated strain values for elevated-temperature measurements. All testing was performed in house in Glenn's Benchmark Test Facility in-plane biaxial load frame.
[On evaluating the robot-based experimental system for biomechanical experiment of human knee].
Deng, Guoyong; Tian, Lianfang; Bai, Bo; Sun, Hui
2010-02-01
This is a report on how we use the hybrid force-displacement control method to load the human knee and analyze the effect and value of our robot experimental system through the biomechanical experiments of total meniscal resection of human knee. The whole robot control system can load continuously on the specimens, thus overcoming the shortcomings of the traditional loading methods which can only load discretely. In the meantime, by using the robot-based testing system, the force (torque) of the specimens and the spatial position under the force can be measured in real-time, which overcomes the shortcomings caused by the separation of force (torque) measurement from displacement measurement and so greatly improves the measurement accuracy.
On the effective point of measurement in megavoltage photon beams.
Kawrakow, Iwan
2006-06-01
This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the chamber design, including the cavity length, the mass density of the wall material, and the size of the central electrode, in addition to the cavity radius. Moreover, the effective point of measurement also depends on the beam quality and the field size. The paper therefore argues that the upstream shift of 0.6 times the cavity radius, recommended in current dosimetry protocols, is inadequate for accurate relative photon beam dosimetry, particularly in the build-up region. On the other hand, once the effective point of measurement is selected appropriately, measured depth-ionization curves can be equated to measured depth-dose curves for all depths within +/- 0.5%.
ERIC Educational Resources Information Center
Stebbins, Molly S.; Stormont, Melissa; Lembke, Erica S.; Wilson, David J.; Clippard, Dana
2012-01-01
The current study detailed the manner in which one school district monitored the effectiveness of the Wilson Reading System for students with disabilities who were experiencing difficulty with reading. Effectiveness was measured by growth in the reading skills that have been documented to be critical for successful readers. Twenty fourth- and…
Locality and universality of quantum memory effects.
Liu, B-H; Wißmann, S; Hu, X-M; Zhang, C; Huang, Y-F; Li, C-F; Guo, G-C; Karlsson, A; Piilo, J; Breuer, H-P
2014-09-11
The modeling and analysis of the dynamics of complex systems often requires to employ non-Markovian stochastic processes. While there is a clear and well-established mathematical definition for non-Markovianity in the case of classical systems, the extension to the quantum regime recently caused a vivid debate, leading to many different proposals for the characterization and quantification of memory effects in the dynamics of open quantum systems. Here, we derive a mathematical representation for the non-Markovianity measure based on the exchange of information between the open system and its environment, which reveals the locality and universality of non-Markovianity in the quantum state space and substantially simplifies its numerical and experimental determination. We further illustrate the application of this representation by means of an all-optical experiment which allows the measurement of the degree of memory effects in a photonic quantum process with high accuracy.
Zeeman Effect in Ruby at High Pressures
NASA Astrophysics Data System (ADS)
Dan, Ioana
2012-02-01
We have developed a versatile fiber-coupled system for magneto-optical spectroscopy measurements at high pressure. The system is based on a miniature Cu-alloy Diamond Anvil Cell (from D'Anvils, Ltd) fitted with a custom-designed He gas-actuated membrane for in-situ pressure control, and coupled with a He transfer cryostat incorporating a superconducting magnet (from Quantum Designs). This system allows optical measurements (Raman, photoluminescence, reflectivity) within wide ranges of pressures (up to 100GPa), temperatures (4.2-300K) and magnetic fields (0-9T). We employ this system to examine the effect of pressure and non-hydrostatic stress on the Zeeman split d-d transitions of Cr^3+ in ruby (Al2O3: Cr^3+). We determine the effect of pressure and non-hydrostaticity on the trigonal crystal field in this material, and discuss the use of the Zeman-split ruby fluorescence as a possible probe for deviatoric stresses in diamond anvil cell experiments.
Automatic scanning and measuring using POLLY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fields, T.
1993-07-01
The HPD and PEPR automatic measuring systems, which have been described by B. Powell and I. Pless at this conference, were developed in the 1960`s to be used for what would now be called {open_quotes}batch processing.{close_quotes} That is, an entire reel of bubble chamber film containing interesting events whose tracks had been rough-digitized would be processed in an extended run by a dedicated computer/precision digitizer hardware system, with no human intervention. Then, at a later time, events for which the precision measurement did not appear to be successful would be handled with some type of {open_quotes}fixup{close_quotes} station or process. Bymore » contrast, the POLLY system included from the start, not only a computer and a precision CRT measuring device, but also a human operator who could have convenient two-way interactions with the computer and could also view the picture directly. Inclusion of a human as a key part of the system had some important beneficial effects, as has been described in the original papers. In this note the author summarizes those effects, and also points out connections between the POLLY system philosophy and subsequent developments in both high energy physics data analysis and computing systems.« less
Investigation of phase distribution using Phame® in-die phase measurements
NASA Astrophysics Data System (ADS)
Buttgereit, Ute; Perlitz, Sascha
2009-03-01
As lithography mask processes move toward 45nm and 32nm node, mask complexity increases steadily, mask specifications tighten and process control becomes extremely important. Driven by this fact the requirements for metrology tools increase as well. Efforts in metrology have been focused on accurately measuring CD linearity and uniformity across the mask, and accurately measuring phase variation on Alternating/Attenuated PSM and transmission for Attenuated PSM. CD control on photo masks is usually done through the following processes: exposure dose/focus change, resist develop and dry etch. The key requirement is to maintain correct CD linearity and uniformity across the mask. For PSM specifically, the effect of CD uniformity for both Alternating PSM and Attenuated PSM and etch depth for Alternating PSM becomes also important. So far phase measurement has been limited to either measuring large-feature phase using interferometer-based metrology tools or measuring etch depth using AFM and converting etch depth into phase under the assumption that trench profile and optical properties of the layers remain constant. However recent investigations show that the trench profile and optical property of layers impact the phase. This effect is getting larger for smaller CD's. The currently used phase measurement methods run into limitations because they are not able to capture 3D mask effects, diffraction limitations or polarization effects. The new phase metrology system - Phame(R) developed by Carl Zeiss SMS overcomes those limitations and enables laterally resolved phase measurement in any kind of production feature on the mask. The resolution of the system goes down to 120nm half pitch at mask level. We will report on tool performance data with respect to static and dynamic phase repeatability focusing on Alternating PSM. Furthermore the phase metrology system was used to investigate mask process signatures on Alternating PSM in order to further improve the overall PSM process performance. Especially global loading effects caused by the pattern density and micro loading effects caused by the feature size itself have been evaluated using the capability of measuring phase in the small production features. The results of this study will be reported in this paper.
USDA-ARS?s Scientific Manuscript database
The possibility of observing shallow groundwater depth and areal extent using satellite measurements can support groundwater models and vast irrigation systems management. Besides, these measurements help to integrate groundwater effects on surface energy balance within land surface models and clima...
Return on Investment: A Cost-Effectiveness Measure for the Texas' Workforce System.
ERIC Educational Resources Information Center
Norris, Davy N.; King, Christopher T.
Texas is developing a return-on-investment (ROI) measure to assess the cost-effectiveness of work force programs. Emphasis is on issues related to conducting cross-program ROI analysis at the level of the Local Workforce Development Board (LWDB) in career or one-stop centers. To make the most appropriate and effective use of ROI, the following…
Multispectral system analysis through modeling and simulation
NASA Technical Reports Server (NTRS)
Malila, W. A.; Gleason, J. M.; Cicone, R. C.
1977-01-01
The design and development of multispectral remote sensor systems and associated information extraction techniques should be optimized under the physical and economic constraints encountered and yet be effective over a wide range of scene and environmental conditions. Direct measurement of the full range of conditions to be encountered can be difficult, time consuming, and costly. Simulation of multispectral data by modeling scene, atmosphere, sensor, and data classifier characteristics is set forth as a viable alternative, particularly when coupled with limited sets of empirical measurements. A multispectral system modeling capability is described. Use of the model is illustrated for several applications - interpretation of remotely sensed data from agricultural and forest scenes, evaluating atmospheric effects in Landsat data, examining system design and operational configuration, and development of information extraction techniques.
Multispectral system analysis through modeling and simulation
NASA Technical Reports Server (NTRS)
Malila, W. A.; Gleason, J. M.; Cicone, R. C.
1977-01-01
The design and development of multispectral remote sensor systems and associated information extraction techniques should be optimized under the physical and economic constraints encountered and yet be effective over a wide range of scene and environmental conditions. Direct measurement of the full range of conditions to be encountered can be difficult, time consuming, and costly. Simulation of multispectral data by modeling scene, atmosphere, sensor, and data classifier characteristics is set forth as a viable alternative, particularly when coupled with limited sets of empirical measurements. A multispectral system modeling capability is described. Use of the model is illustrated for several applications - interpretation of remotely sensed data from agricultural and forest scenes, evaluating atmospheric effects in LANDSAT data, examining system design and operational configuration, and development of information extraction techniques.
NASA Technical Reports Server (NTRS)
Yee, C. P.; Kelbel, D. A.; Lee, T.; Dunham, J. B.; Mistretta, G. D.
1990-01-01
The influence of ionospheric refraction on orbit determination was studied through the use of the Orbit Determination Error Analysis System (ODEAS). The results of a study of the orbital state estimate errors due to the ionospheric refraction corrections, particularly for measurements involving spacecraft-to-spacecraft tracking links, are presented. In current operational practice at the Goddard Space Flight Center (GSFC) Flight Dynamics Facility (FDF), the ionospheric refraction effects on the tracking measurements are modeled in the Goddard Trajectory Determination System (GTDS) using the Bent ionospheric model. While GTDS has the capability of incorporating the ionospheric refraction effects for measurements involving ground-to-spacecraft tracking links, such as those generated by the Ground Spaceflight Tracking and Data Network (GSTDN), it does not have the capability to incorporate the refraction effects for spacecraft-to-spacecraft tracking links for measurements generated by the Tracking and Data Relay Satellite System (TDRSS). The lack of this particular capability in GTDS raised some concern about the achievable accuracy of the estimated orbit for certain classes of spacecraft missions that require high-precision orbits. Using an enhanced research version of GTDS, some efforts have already been made to assess the importance of the spacecraft-to-spacecraft ionospheric refraction corrections in an orbit determination process. While these studies were performed using simulated data or real tracking data in definitive orbit determination modes, the study results presented here were obtained by means of covariance analysis simulating the weighted least-squares method used in orbit determination.
Evaluation of OH laser-induced fluorescence techniques for supersonic combustion diagnostics
NASA Technical Reports Server (NTRS)
Quagliaroli, T. M.; Laufer, G.; Krauss, R. H.; Mcdaniel, J. C., Jr.
1992-01-01
The limitations on application of dye laser and narrowband tunable KrF excimer laser systems to planar OH fluorescence measurements in supersonic combustion test facilities are examined. Included in the analysis are effects of collisional quenching, beam absorption, fluorescence trapping, and signal strengths on achievable measurement accuracy using several excitation and detection options for either of the two laser systems. Dye-based laser systems are found to be the method of choice for imaging OH concentrations less than 10 exp 15 per cu cm, while the KrF based systems provide significant reduction in measurement ambiguity for concentrations in excess of 10 exp 15 per cu cm.
International Instrumentation Symposium, 38th, Las Vegas, NV, Apr. 26-30, 1992, Proceedings
NASA Astrophysics Data System (ADS)
The present volume on aerospace instrumentation discusses computer applications, blast and shock, implementation of the Clean Air Act amendments, and thermal systems. Attention is given to measurement uncertainty/flow measurement, data acquisition and processing, force/acceleration/motion measurements, and hypersonics/reentry vehicle systems. Topics addressed include wind tunnels, real time systems, and pressure effects. Also discussed are a distributed data and control system for space simulation and thermal testing a stepwise shockwave velocity determinator, computer tracking and decision making, the use of silicon diodes for detecting the liquid-vapor interface in hydrogen, and practical methods for analysis of uncertainty propagation.
Advances in Spectral Electrical Impedance Tomography (EIT) for Near-Surface Geophysical Exploration
NASA Astrophysics Data System (ADS)
Huisman, J. A.; Zimmermann, E.; Kelter, M.; Zhao, Y.; Bukhary, T. H.; Vereecken, H.
2016-12-01
Recent advances in spectral Electrical Impedance Tomography (EIT) now allow to obtain the complex electrical conductivity distribution in near-surface environments with a high accuracy for a broad range of frequencies (mHz - kHz). One of the key advances has been the development of correction methods to account for inductive coupling effects between wires used for current and potential measurements and capacitive coupling between cables and the subsurface environment. In this study, we first review these novel correction methods and then illustrate how the consideration of capacitive and inductive coupling improves spectral EIT results. For this, borehole EIT measurements were made in a shallow aquifer using a custom-made EIT system with two electrode chains each consisting of eight active electrodes with a separation of 1 m. The EIT measurements were inverted with and without consideration of inductive and capacitive coupling effects. The inversion results showed that spatially and spectrally consistent imaging results can only be obtained when inductive coupling effects are considered (phase accuracy of 1-2 mrad at 1 kHz). Capacitive coupling effects were found to be of secondary importance for the set-up used here, but its importance will increase when longer cables are used. Although these results are promising, the active electrode chains can only be used with our custom-made EIT system. Therefore, we also explored to what extent EIT measurements with passive electrode chains amenable to commercially available EIT measurement systems can be corrected for coupling effects. It was found that EIT measurements with passive unshielded cables could not be corrected above 100 Hz because of the strong but inaccurately known capacitive coupling between the electrical wires. However, it was possible to correct EIT measurements with passive shielded cables, and the final accuracy of the phase measurements was estimated to be 2-4 mrad at 1 kHz.
Development of Performance Dashboards in Healthcare Sector: Key Practical Issues
Ghazisaeidi, Marjan; Safdari, Reza; Torabi, Mashallah; Mirzaee, Mahboobeh; Farzi, Jebraeil; Goodini, Azadeh
2015-01-01
Background: Static nature of performance reporting systems in health care sector has resulted in inconsistent, incomparable, time consuming, and static performance reports that are not able to transparently reflect a round picture of performance and effectively support healthcare managers’ decision makings. So, the healthcare sector needs interactive performance management tools such as performance dashboards to measure, monitor, and manage performance more effectively. The aim of this article was to identify key issues that need to be addressed for developing high-quality performance dashboards in healthcare sector. Methods: A literature review was established to search electronic research databases, e-journals collections, and printed journals, books, dissertations, and theses for relevant articles. The search strategy interchangeably used the terms of “dashboard”, “performance measurement system”, and “executive information system” with the term of “design” combined with operator “AND”. Search results (n=250) were adjusted for duplications, screened based on their abstract relevancy and full-text availability (n=147) and then assessed for eligibility (n=40). Eligible articles were included if they had explicitly focused on dashboards, performance measurement systems or executive information systems design. Finally, 28 relevant articles included in the study. Results: Creating high-quality performance dashboards requires addressing both performance measurement and executive information systems design issues. Covering these two fields, identified contents were categorized to four main domains: KPIs development, Data Sources and data generation, Integration of dashboards to source systems, and Information presentation issues. Conclusion: This study implies the main steps to develop dashboards for the purpose of performance management. Performance dashboards developed on performance measurement and executive information systems principles and supported by proper back-end infrastructure will result in creation of dynamic reports that help healthcare managers to consistently measure the performance, continuously detect outliers, deeply analyze causes of poor performance, and effectively plan for the future. PMID:26635442
NASA Astrophysics Data System (ADS)
Lu, Boyin; Zhao, Meirong
1994-09-01
A new-type active vibration isolation system is developed for ultra-precision measuring system. It is composed of three sets of 3D Laser interferometer transducer and six groups of piezoelectric displacement executor to constrain six degrees of space movement and to realize real-time compensation of vibration. The active vibration isolation system can effectively eliminate low-frequency vibrations. Combined with passive vibration isolation system, it gives better vibration isolation effect.
Lightning Protection and Instrumentation at Kennedy Space Center
NASA Technical Reports Server (NTRS)
Colon, Jose L.
2005-01-01
Lightning is a natural phenomenon, but can be dangerous. Prevention of lightning is a physical impossibility and total protection requires compromises on costs and effects, therefore prediction and measurements of the effects that might be produced by iightn:ing is a most at locat:ions where people or sensitive systems and equipment are exposed. This is the case of the launching pads for the Space Shuttle at Kennedy Space Center (KSC) of the National Aeronautics and Space Administration. This report summarizes lightring phenomena with a brief explanation of lightning generation and lightning activity as related to KSC. An analysis of the instrumentation used at the launching pads for measurements of lightning effects with alternatives to improve the protection system and up-grade the actual instrumentation system is indicated.
Evaluation of Stress Distribution in Magnetic Materials Using a Magnetic Imaging System
NASA Astrophysics Data System (ADS)
Lo, C. C. H.; Paulsen, J. A.; Jiles, D. C.
2004-02-01
The feasibility of detecting stress distribution in magnetic materials by magnetic hysteresis and Barkhausen effect measurements has been evaluated using a newly developed magnetic imaging system. The system measured hysteresis loops and Barkhausen effect signals with the use of a surface sensor that was scanned over the material. The data were converted into a two-dimensional image showing spatial variations of the magnetic properties from which mechanical conditions of the materials can be inferred. In this study a nickel plate machined into a shear-beam load cell configuration was used. By applying a stress along the neutral axis, various stress patterns such as shear stress and stress concentration could be produced in different regions of the sample. The scanned images of magnetic properties such as coercivity and rms value of Barkhausen effect signal exhibited patterns similar to the stress distribution calculated using finite element model (FEM), in particular in the regions where a high stress level and a high stress gradient existed. For direct comparison, images of magnetic properties were simulated based on the results of FEM stress calculation and experimental calibration of the magnetomechanical effect. The simulated images were found to closely resemble the scanned images, indicating the possibility of measuring stress distribution by mapping magnetic properties using the magnetic imaging system.
NASA Astrophysics Data System (ADS)
Pang, Hongfeng; Zhu, XueJun; Pan, Mengchun; Zhang, Qi; Wan, Chengbiao; Luo, Shitu; Chen, Dixiang; Chen, Jinfei; Li, Ji; Lv, Yunxiao
2016-12-01
Misalignment error is one key factor influencing the measurement accuracy of geomagnetic vector measurement system, which should be calibrated with the difficulties that sensors measure different physical information and coordinates are invisible. A new misalignment calibration method by rotating a parallelepiped frame is proposed. Simulation and experiment result show the effectiveness of calibration method. The experimental system mainly contains DM-050 three-axis fluxgate magnetometer, INS (inertia navigation system), aluminium parallelepiped frame, aluminium plane base. Misalignment angles are calculated by measured data of magnetometer and INS after rotating the aluminium parallelepiped frame on aluminium plane base. After calibration, RMS error of geomagnetic north, vertical and east are reduced from 349.441 nT, 392.530 nT and 562.316 nT to 40.130 nT, 91.586 nT and 141.989 nT respectively.
Observable measure of quantum coherence in finite dimensional systems.
Girolami, Davide
2014-10-24
Quantum coherence is the key resource for quantum technology, with applications in quantum optics, information processing, metrology, and cryptography. Yet, there is no universally efficient method for quantifying coherence either in theoretical or in experimental practice. I introduce a framework for measuring quantum coherence in finite dimensional systems. I define a theoretical measure which satisfies the reliability criteria established in the context of quantum resource theories. Then, I present an experimental scheme implementable with current technology which evaluates the quantum coherence of an unknown state of a d-dimensional system by performing two programmable measurements on an ancillary qubit, in place of the O(d2) direct measurements required by full state reconstruction. The result yields a benchmark for monitoring quantum effects in complex systems, e.g., certifying nonclassicality in quantum protocols and probing the quantum behavior of biological complexes.
Effects of Systemic Hydration on Vocal Acoustics of 18- to 35-Year-Old Females
ERIC Educational Resources Information Center
Franca, Maria Claudia; Simpson, Kenneth O.
2012-01-01
The influence of body hydration and vocal acoustics was investigated in this study. Effects of two levels of hydration on objective measures of vocal acoustics were explored. In an attempt to reduce variability in the degree of systemic hydration and to induce a state of systemic dehydration, participants were instructed to refrain from ingestion…
Multi-Course Comparison of Traditional versus Web-Based Course Delivery Systems
ERIC Educational Resources Information Center
Weber, J. Michael; Lennon, Ron
2007-01-01
The purpose of this paper is to measure and compare the effectiveness of a Web-based course delivery system to a traditional course delivery system. The results indicate that a web-based course is effective and equivalent to a traditional classroom environment. As with the implementation of all new technologies, there are some pros and cons that…
Method and apparatus for diagnosing breached fuel elements
Gross, K.C.; Lambert, J.D.B.; Nomura, S.
1987-03-02
The invention provides an apparatus and method for diagnosing breached fuel elements in a nuclear reactor. A detection system measures the activity of isotopes from the cover gas in the reactor. A data acquisition and processing system monitors the detection system and corrects for the effects of the cover-gas clean up system on the measured activity and further calculates the derivative curve of the corrected activity as a function of time. A plotting system graphs the derivative curve, which represents the instantaneous release rate of fission gas from a breached fuel element. 8 figs.
High temperature hall effect measurement system design, measurement and analysis
NASA Astrophysics Data System (ADS)
Berkun, Isil
A reliable knowledge of the transport properties of semiconductor materials is essential for the development and understanding of a number of electronic devices. In this thesis, the work on developing a Hall Effect measurement system with software based data acqui- sition and control for a temperature range of 300K-700K will be described. A system was developed for high temperature measurements of materials including single crystal diamond, poly-crystalline diamond, and thermoelectric compounds. An added capability for monitor- ing the current versus voltage behavior of the contacts was used for studying the influence of ohmic and non-ohmic contacts on Hall Effect measurements. The system has been primar- ily used for testing the transport properties of boron-doped single crystal diamond (SCD) deposited in a microwave plasma-assisted chemical vapor deposition (MPCVD) reactor [1]. Diamond has several outstanding properties that are of high interest for its development as an electronic material. These include a relatively wide band gap of 5.5 (eV), high thermal conductivity, high mobility, high saturation velocity, and a high breakdown voltage. For a temperature range of 300K-700K, IV curves, Hall mobilities and carrier concentrations are shown. Temperature dependent Hall effect measurements have shown carrier concentrations from below 1017cm --3 to approximately 1021 cm--3 with mobilities ranging from 763( cm2/V s) to 0.15(cm 2/V s) respectively. Simulation results have shown the effects of single and mixed carrier models, activation energies, effective mass and doping concentrations. These studies have been helpful in the development of single crystal diamond for diode applications. Reference materials of Ge and GaAs were used to test the Hall Effect system. The system was also used to characterize polycrystalline diamond deposited on glass for electrochemical applications, and Mg2(Si,Sn) compounds which are promising candidates of low-cost, light weight and non-toxic thermoelectric materials made from abundant elements and are suited for power generation application in the intermediate temperature range of (600 K - 800 K). In this work the thermoelectric materials were synthesized by a solid-state reac- tion using a molten-salt sealing method. The ingots produced were then powder processed, followed by pulsed electric sintering (PECS) densification. A set of Mg2.08Si0.4--x Sn0.6Sbx (0 ≤ x ≤ 0.072) compounds were investigated and a peak ZT of 1.50 was obtained at 716 K in Mg2.08Si 0.364Sn0.6Sb0.036 [2]. The high ZT value is related to a high electrical conductivity in these samples, which are possibly caused by a magnesium deficiency in the final prod- uct. Analysis of the measured results using LabVIEW and MATLAB developed programs showed good agreement with expected results and gave insight on mixed carrier dopant concentrations. [1] I. Berkun, S. N. Demlow, N. Suwanmonkha, T. P. Hogan, and T. A. Grotjohn, "Hall Effect Measurement System for Characterization of Doped Single Crystal Diamond," in MRS Proceedings, vol. 1511, Cambridge Univ Press, 2013. [2] P. Gao, I. Berkun, R. D. Schmidt, M. F. Luzenski, X. Lu, P. B. Sarac, E. D. Case, and T. P. Hogan, "Transport and Mechanical Properties of High-ZT Mg2. 08si0. 4- x Sn0. 6sb x Thermoelectric Materials," Journal of Electronic Materials, pp. 1--14, 2013.
Choi, Se Woon; Kim, Ill Soo; Park, Jae Hwan; Kim, Yousok; Sohn, Hong Gyoo; Park, Hyo Seon
2013-01-01
The outrigger truss system is one of the most frequently used lateral load resisting structural systems. However, little research has been reported on the effect of installation of outrigger trusses on improvement of lateral stiffness of a high-rise building through full-scale measurements. In this paper, stiffness changes of a high-rise building due to installation of outrigger trusses have been evaluated by measuring lateral displacements using a global positioning system (GPS). To confirm the error range of the GPS measurement system used in the full-scale measurement tests, the GPS displacement monitoring system is investigated through a free vibration test of the experimental model. Then, for the evaluation of lateral stiffness of a high-rise building under construction, the GPS displacement monitoring system is applied to measurements of lateral displacements of a 66-story high-rise building before and after installation of outrigger truss. The stiffness improvement of the building before and after the installation is confirmed through the changes of the natural frequencies and the ratios of the base shear forces to the roof displacements. PMID:24233025
Weighted Geometric Dilution of Precision Calculations with Matrix Multiplication
Chen, Chien-Sheng
2015-01-01
To enhance the performance of location estimation in wireless positioning systems, the geometric dilution of precision (GDOP) is widely used as a criterion for selecting measurement units. Since GDOP represents the geometric effect on the relationship between measurement error and positioning determination error, the smallest GDOP of the measurement unit subset is usually chosen for positioning. The conventional GDOP calculation using matrix inversion method requires many operations. Because more and more measurement units can be chosen nowadays, an efficient calculation should be designed to decrease the complexity. Since the performance of each measurement unit is different, the weighted GDOP (WGDOP), instead of GDOP, is used to select the measurement units to improve the accuracy of location. To calculate WGDOP effectively and efficiently, the closed-form solution for WGDOP calculation is proposed when more than four measurements are available. In this paper, an efficient WGDOP calculation method applying matrix multiplication that is easy for hardware implementation is proposed. In addition, the proposed method can be used when more than exactly four measurements are available. Even when using all-in-view method for positioning, the proposed method still can reduce the computational overhead. The proposed WGDOP methods with less computation are compatible with global positioning system (GPS), wireless sensor networks (WSN) and cellular communication systems. PMID:25569755
NASA Astrophysics Data System (ADS)
Wood, Tim J.; Moore, Craig S.; Saunderson, John R.; Beavis, Andrew W.
2018-01-01
Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a useful metric for the optimisation of clinical imaging systems. The aim of this study was to develop a methodology for measuring eDQE and eDE on a Philips microdose mammography (MDM) L30 photon counting scanning system, and to compare performance with two conventional flat panel systems. A custom made lead-blocker was manufactured to enable the accurate determination of dose measurements, and modulation transfer functions were determined free-in-air at heights of 2, 4 and 6 cm above the breast support platform. eDQE were calculated for a Philips MDM L30, Hologic Dimensions and Siemens Inspiration digital mammography system for 2, 4 and 6 cm thick poly(methyl methacrylate) (PMMA). The beam qualities (target/filter and kilovoltage) assessed were those selected by the automatic exposure control, and anti-scatter grids were used where available. Measurements of eDQE demonstrate significant differences in performance between the slit- and scan-directions for the photon counting imaging system. MTF has been shown to be the limiting factor in the scan-direction, which results in a rapid fall in eDQE at mid-to-high spatial frequencies. A comparison with two flat panel mammography systems demonstrates that this may limit image quality for small details, such as micro-calcifications, which correlates with a more conventional image quality assessment with the CDMAM phantom. eDE has shown the scanning photon counting system offers superior performance for low spatial frequencies, which will be important for the detection of large low contrast masses. Both eDQE and eDE are proposed as useful metrics that should enable optimisation of the Philips MDM L30.
NASA Technical Reports Server (NTRS)
Claus, R. O.; Bennett, K. D.; Jackson, B. S.
1986-01-01
The application of fiber-optical time domain reflectometry (OTDR) to nondestructive quantitative measurements of distributed internal strain in graphite-epoxy composites, using optical fiber waveguides imbedded between plies, is discussed. The basic OTDR measurement system is described, together with the methods used to imbed optical fibers within composites. Measurement results, system limitations, and the effect of the imbedded fiber on the integrity of the host composite material are considered.
Feedback control of nonlinear quantum systems: a rule of thumb.
Jacobs, Kurt; Lund, Austin P
2007-07-13
We show that in the regime in which feedback control is most effective - when measurements are relatively efficient, and feedback is relatively strong - then, in the absence of any sharp inhomogeneity in the noise, it is always best to measure in a basis that does not commute with the system density matrix than one that does. That is, it is optimal to make measurements that disturb the state one is attempting to stabilize.
Keatley, David; Clarke, David D; Hagger, Martin S
2013-09-01
Research into the effects of individuals'autonomous motivation on behaviour has traditionally adopted explicit measures and self-reported outcome assessment. Recently, there has been increased interest in the effects of implicit motivational processes underlying behaviour from a self-determination theory (SDT) perspective. The aim of the present research was to provide support for the predictive validity of an implicit measure of autonomous motivation on behavioural persistence on two objectively measurable tasks. SDT and a dual-systems model were adopted as frameworks to explain the unique effects offered by explicit and implicit autonomous motivational constructs on behavioural persistence. In both studies, implicit autonomous motivation significantly predicted unique variance in time spent on each task. Several explicit measures of autonomous motivation also significantly predicted persistence. Results provide support for the proposed model and the inclusion of implicit measures in research on motivated behaviour. In addition, implicit measures of autonomous motivation appear to be better suited to explaining variance in behaviours that are more spontaneous or unplanned. Future implications for research examining implicit motivation from dual-systems models and SDT approaches are outlined. © 2012 The British Psychological Society.
Characteristic Evaluation on Cooling Performance of Thermoelectric Modules.
Seo, Sae Rom; Han, Seungwoo
2015-10-01
The aim of this work is to develop a performance evaluation system for thermoelectric cooling modules. We describe the design of such a system, composed of a vacuum chamber with a heat sink along with a metal block to measure the absorbed heat Qc. The system has a simpler structure than existing water-cooled or air-cooled systems. The temperature difference between the cold and hot sides of the thermoelectric module ΔT can be accurately measured without any effects due to convection, and the temperature equilibrium time is minimized compared to a water-cooled system. The evaluation system described here can be used to measure characteristic curves of Qc as a function of ΔT, as well as the current-voltage relations. High-performance thermoelectric systems can therefore be developed using optimal modules evaluated with this system.
Pedrini, Giancarlo; Alexeenko, Igor; Osten, Wolfgang; Schnars, Ulf
2006-02-10
A method based on pulsed digital holographic interferometry for the measurement of dynamic deformations of a surface by using a moving system is presented. The measuring system may move with a speed of several meters per minute and can measure deformation of the surface with an accuracy of better than 50 nm. The deformation is obtained by comparison of the wavefronts recorded at different times with different laser pulses produced by a Nd:YAG laser. The effect due to the movement of the measuring system is compensated for by digital processing of the different holograms. The system is well suited for on-line surveillance of a dynamic process such as laser welding and friction stir welding. Experimental results are presented, and the advantages of the method are discussed.
NASA Astrophysics Data System (ADS)
Reagan, Daniel; Sabato, Alessandro; Niezrecki, Christopher
2017-04-01
Civil engineering structures such as bridges, buildings, and tunnels continue to be used despite aging and deterioration well past their design life. In 2013, the American Society of Civil Engineers (ASCE) rated the state of the U.S. bridges as mediocre, despite the $12.8 billion USD annually invested. Traditional inspection and monitoring techniques may produce inconsistent results, are labor intensive and too time-consuming to be considered effective for large-scale monitoring. Therefore, new structural health monitoring systems must be developed that are automated, highly accurate, minimally invasive, and cost effective. Three-dimensional (3D) digital image correlation (DIC) systems possess the capability of extracting full-field strain, displacement, and geometry profiles. Furthermore, as this measurement technique is implemented within an Unmanned Aerial Vehicle (UAV) the capability to expedite the optical-based measurement process is increased as well as the infrastructure downtime being reduced. These resulting integrity maps of the structure of interest can be easily interpreted by trained personal. Within this paper, the feasibility of performing DIC measurements using a pair of cameras installed on a UAV is shown. Performance is validated with in-flight measurements. Also, full-field displacement monitoring, 3D measurement stitching, and 3D point-tracking techniques are employed in conjunction with 3D mapping and data management software. The results of these experiments show that the combination of autonomous flight with 3D DIC and other non-contact measurement systems provides a highly valuable and effective civil inspection platform.
Zhou, Qifan; Zhang, Hai; Li, You; Li, Zheng
2015-09-18
The main aim of this paper is to develop a low-cost GNSS/MEMS-IMU tightly-coupled integration system with aiding information that can provide reliable position solutions when the GNSS signal is challenged such that less than four satellites are visible in a harsh environment. To achieve this goal, we introduce an adaptive tightly-coupled integration system with height and heading aiding (ATCA). This approach adopts a novel redundant measurement noise estimation method for an adaptive Kalman filter application and also augments external measurements in the filter to aid the position solutions, as well as uses different filters to deal with various situations. On the one hand, the adaptive Kalman filter makes use of the redundant measurement system's difference sequence to estimate and tune noise variance instead of employing a traditional innovation sequence to avoid coupling with the state vector error. On the other hand, this method uses the external height and heading angle as auxiliary references and establishes a model for the measurement equation in the filter. In the meantime, it also changes the effective filter online based on the number of tracked satellites. These measures have increasingly enhanced the position constraints and the system observability, improved the computational efficiency and have led to a good result. Both simulated and practical experiments have been carried out, and the results demonstrate that the proposed method is effective at limiting the system errors when there are less than four visible satellites, providing a satisfactory navigation solution.
NASA Astrophysics Data System (ADS)
Zhao, Y.; Zimmermann, E.; Huisman, J. A.; Treichel, A.; Wolters, B.; van Waasen, S.; Kemna, A.
2013-08-01
Electrical impedance tomography (EIT) is gaining importance in the field of geophysics and there is increasing interest for accurate borehole EIT measurements in a broad frequency range (mHz to kHz) in order to study subsurface properties. To characterize weakly polarizable soils and sediments with EIT, high phase accuracy is required. Typically, long electrode cables are used for borehole measurements. However, this may lead to undesired electromagnetic coupling effects associated with the inductive coupling between the double wire pairs for current injection and potential measurement and the capacitive coupling between the electrically conductive shield of the cable and the electrically conductive environment surrounding the electrode cables. Depending on the electrical properties of the subsurface and the measured transfer impedances, both coupling effects can cause large phase errors that have typically limited the frequency bandwidth of field EIT measurements to the mHz to Hz range. The aim of this paper is to develop numerical corrections for these phase errors. To this end, the inductive coupling effect was modeled using electronic circuit models, and the capacitive coupling effect was modeled by integrating discrete capacitances in the electrical forward model describing the EIT measurement process. The correction methods were successfully verified with measurements under controlled conditions in a water-filled rain barrel, where a high phase accuracy of 0.8 mrad in the frequency range up to 10 kHz was achieved. The corrections were also applied to field EIT measurements made using a 25 m long EIT borehole chain with eight electrodes and an electrode separation of 1 m. The results of a 1D inversion of these measurements showed that the correction methods increased the measurement accuracy considerably. It was concluded that the proposed correction methods enlarge the bandwidth of the field EIT measurement system, and that accurate EIT measurements can now be made in the mHz to kHz frequency range. This increased accuracy in the kHz range will allow a more accurate field characterization of the complex electrical conductivity of soils and sediments, which may lead to the improved estimation of saturated hydraulic conductivity from electrical properties. Although the correction methods have been developed for a custom-made EIT system, they also have potential to improve the phase accuracy of EIT measurements made with commercial systems relying on multicore cables.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peng, Jun, E-mail: pengjun@cimm.com.cn; Zhang, Li, E-mail: zhangli@cimm.com.cn; School of Instrumentation Science and Opto-electronics Engineering, Beihang University, Beijing
The moment of inertia calibration system is developed by Changcheng Institute of Metrology and Measurement (CIMM). Rotation table - torsional spring system is used to generate angular vibration, and laser vibrometer is used to measure rotational angle and the vibration period. The object to be measured is mounted on the top of the rotation table. The air-bearing system is elaborately manufactured which reduce the friction of the angular movement and increase measurement accuracy. Heterodyne laser interferometer collaborates with column diffraction grating is used in the measurement of angular movement. Experiment shows the method of measuring oscillating angle and period introducedmore » in this paper is stable and the time resolution is high. When the air damping effect can’t be neglected in moment of inertia measurement, the periodic waveform area ratio method is introduced to calculate damping ratio and obtain the moment of inertia.« less
Fitzgerald, Sarah; Murphy, Aileen; Kirby, Ann; Geaney, Fiona; Perry, Ivan J
2018-03-03
To evaluate the costs, benefits and cost-effectiveness of complex workplace dietary interventions, involving nutrition education and system-level dietary modification, from the perspective of healthcare providers and employers. Single-study economic evaluation of a cluster-controlled trial (Food Choice at Work (FCW) study) with 1-year follow-up. Four multinational manufacturing workplaces in Cork, Ireland. 517 randomly selected employees (18-65 years) from four workplaces. Cost data were obtained from the FCW study. Nutrition education included individual nutrition consultations, nutrition information (traffic light menu labelling, posters, leaflets and emails) and presentations. System-level dietary modification included menu modification (restriction of fat, sugar and salt), increase in fibre, fruit discounts, strategic positioning of healthier alternatives and portion size control. The combined intervention included nutrition education and system-level dietary modification. No intervention was implemented in the control. The primary outcome was an improvement in health-related quality of life, measured using the EuroQoL 5 Dimensions 5 Levels questionnaire. The secondary outcome measure was reduction in absenteeism, which is measured in monetary amounts. Probabilistic sensitivity analysis (Monte Carlo simulation) assessed parameter uncertainty. The system-level intervention dominated the education and combined interventions. When compared with the control, the incremental cost-effectiveness ratio (€101.37/quality-adjusted life-year) is less than the nationally accepted ceiling ratio, so the system-level intervention can be considered cost-effective. The cost-effectiveness acceptability curve indicates there is some decision uncertainty surrounding this, arising from uncertainty surrounding the differences in effectiveness. These results are reiterated when the secondary outcome measure is considered in a cost-benefit analysis, whereby the system-level intervention yields the highest net benefit (€56.56 per employee). System-level dietary modification alone offers the most value per improving employee health-related quality of life and generating net benefit for employers by reducing absenteeism. While system-level dietary modification strategies are potentially sustainable obesity prevention interventions, future research should include long-term outcomes to determine if improvements in outcomes persist. ISRCTN35108237; Post-results. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
Strengthening the Canadian alcohol advertising regulatory system.
Heung, Carly M; Rempel, Benjamin; Krank, Marvin
2012-05-24
Research evidence points to harmful effects from alcohol advertising among children and youth. In particular, exposure to alcohol advertising has been associated with adolescents drinking both earlier and heavier. Although current federal and provincial guidelines have addressed advertising practices to prevent underage drinking, practice has not been supported by existing policy. While protective measures such as social marketing campaigns have the potential for counteracting the effects from alcohol advertising, the effectiveness of such measures can be easily drowned out with increasing advertising activities from the alcohol industry, especially without effective regulation. Research reviewed by the European Focus on Alcohol Safe Environment (FASE) Project has identified a set of key elements that are necessary to make alcohol advertising policy measures effective at protecting children and youth from the harmful effects of alcohol marketing. Using these key elements as an evaluation framework, there are critical components in the Canadian alcohol advertising regulatory system that clearly require strengthening. To protect impressionable children and youth against the harmful effects of alcohol advertising, 13 recommendations to strengthen current alcohol advertising regulations in Canada are provided for Canadian policy-makers, advertising standard agencies, and public health groups.
A design of optical modulation system with pixel-level modulation accuracy
NASA Astrophysics Data System (ADS)
Zheng, Shiwei; Qu, Xinghua; Feng, Wei; Liang, Baoqiu
2018-01-01
Vision measurement has been widely used in the field of dimensional measurement and surface metrology. However, traditional methods of vision measurement have many limits such as low dynamic range and poor reconfigurability. The optical modulation system before image formation has the advantage of high dynamic range, high accuracy and more flexibility, and the modulation accuracy is the key parameter which determines the accuracy and effectiveness of optical modulation system. In this paper, an optical modulation system with pixel level accuracy is designed and built based on multi-points reflective imaging theory and digital micromirror device (DMD). The system consisted of digital micromirror device, CCD camera and lens. Firstly we achieved accurate pixel-to-pixel correspondence between the DMD mirrors and the CCD pixels by moire fringe and an image processing of sampling and interpolation. Then we built three coordinate systems and calculated the mathematic relationship between the coordinate of digital micro-mirror and CCD pixels using a checkerboard pattern. A verification experiment proves that the correspondence error is less than 0.5 pixel. The results show that the modulation accuracy of system meets the requirements of modulation. Furthermore, the high reflecting edge of a metal circular piece can be detected using the system, which proves the effectiveness of the optical modulation system.
NASA Astrophysics Data System (ADS)
Zhao, Ziyue; Zhu, Jigui; Yang, Linghui; Lin, Jiarui
2015-10-01
The present scanning system consists of an industrial robot and a line-structured laser sensor which uses the industrial robot as a position instrument to guarantee the accuracy. However, the absolute accuracy of an industrial robot is relatively poor compared with the good repeatability in the manufacturing industry. This paper proposes a novel method using the workspace measurement and positioning system (wMPS) to remedy the lack of accuracy of the industrial robot. In order to guarantee the positioning accuracy of the system, the wMPS which is a laser-based measurement technology designed for large-volume metrology applications is brought in. Benefitting from the wMPS, this system can measure different cell-areas by the line-structured laser sensor and fuse the measurement data of different cell-areas by using the wMPS accurately. The system calibration which is the procedure to acquire and optimize the structure parameters of the scanning system is also stated in detail in this paper. In order to verify the feasibility of the system for scanning the large free-form surface, an experiment is designed to scan the internal surface of the door of a car-body in white. The final results show that the measurement data of the whole measuring areas have been jointed perfectly and there is no mismatch in the figure especially in the hole measuring areas. This experiment has verified the rationality of the system scheme, the correctness and effectiveness of the relevant methods.
Characterization of a Low-Cost Multiparameter Sensor for Solar Resource Applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Habte, Aron M; Sengupta, Manajit; Andreas, Afshin M
Low-cost, multiparameter sensing and measurement devices enable cost-effective monitoring of the functional, operational reliability, efficiency, and resiliency of the electric grid. The National Renewable Research Laboratory (NREL) Solar Radiation Research Laboratory (SRRL), in collaboration with Arable Labs, Inc., deployed Arable Lab's Mark multiparameter sensor system. The device measures the downwelling and upwelling shortwave solar resource and longwave radiation, humidity, air temperature, and ground temperature. The system is also equipped with six downward-and upward-facing narrowband spectrometer channels that measure spectral radiation and surface spectral reflectance. This study describes the shortwave calibration, characterization, and validation of measurement accuracy of this instrument bymore » comparison with existing instruments that are part of NREL-SRRL's Baseline Measurement System.« less
A Parkinson's disease measurement system using laser lines and a CMOS image sensor.
Chang, Rong-Seng; Chiu, Jen-Hwey; Chen, Fang-Pey; Chen, Jyh-Cheng; Yang, Jen-Lin
2011-01-01
This paper presents a non-invasive, non-contact system for the measurement of the arterial dorsum manus vibration waveforms of Parkinson disease patients. The laser line method is applied to detect the dorsum manus vibration in rest and postural situations. The proposed measurement system mainly consists of a laser diode and a low cost complementary metal-oxide semiconductor (CMOS) image sensor. Laser line and centroid methods are combined with the Fast Fourier Transform (FFT) in this study. The shape and frequency and relative frequency of the dorsum manus vibration waveforms can be detected rapidly using our Parkinson's disease measurement system. A laser line near the wrist joint is used as the testing line. The experimental results show an obvious increase in the amplitude and frequency of dorsum manus variation in the measured region in patients suffering from Parkinson's disease, indicating the obvious effects of the disease. Both in postural and rest state measurements, as the patient disease age increases the vibration frequency increases. The measurement system is well suited for evaluating and pre-diagnosing early stage Parkinson's disease.
Using Replicates in Information Retrieval Evaluation.
Voorhees, Ellen M; Samarov, Daniel; Soboroff, Ian
2017-09-01
This article explores a method for more accurately estimating the main effect of the system in a typical test-collection-based evaluation of information retrieval systems, thus increasing the sensitivity of system comparisons. Randomly partitioning the test document collection allows for multiple tests of a given system and topic (replicates). Bootstrap ANOVA can use these replicates to extract system-topic interactions-something not possible without replicates-yielding a more precise value for the system effect and a narrower confidence interval around that value. Experiments using multiple TREC collections demonstrate that removing the topic-system interactions substantially reduces the confidence intervals around the system effect as well as increases the number of significant pairwise differences found. Further, the method is robust against small changes in the number of partitions used, against variability in the documents that constitute the partitions, and the measure of effectiveness used to quantify system effectiveness.
Using Replicates in Information Retrieval Evaluation
VOORHEES, ELLEN M.; SAMAROV, DANIEL; SOBOROFF, IAN
2018-01-01
This article explores a method for more accurately estimating the main effect of the system in a typical test-collection-based evaluation of information retrieval systems, thus increasing the sensitivity of system comparisons. Randomly partitioning the test document collection allows for multiple tests of a given system and topic (replicates). Bootstrap ANOVA can use these replicates to extract system-topic interactions—something not possible without replicates—yielding a more precise value for the system effect and a narrower confidence interval around that value. Experiments using multiple TREC collections demonstrate that removing the topic-system interactions substantially reduces the confidence intervals around the system effect as well as increases the number of significant pairwise differences found. Further, the method is robust against small changes in the number of partitions used, against variability in the documents that constitute the partitions, and the measure of effectiveness used to quantify system effectiveness. PMID:29905334
Online terahertz thickness measurement in films and coatings
NASA Astrophysics Data System (ADS)
Duling, Irl N.; White, Jeffrey S.
2017-02-01
Pulsed terahertz systems are currently being deployed for online process control and quality control of multi-layered products for use in the building products and aerospace industries. While many laboratory applications of terahertz can allow waveforms to be acquired at rates of 1 - 40 Hz, online applications require measurement rates of in excess of 100Hz. The existing technologies of thickness measurement (nuclear, x-ray, or laser gauges) have rates between 100 and 1000 Hz. At these rates, the single waveform bandwidth must still remain at 2THz or above to allow thinner layers to be measured. In the applications where terahertz can provide unique capability (e.g. multi-layer thickness, delamination, density) long-term stability must be guaranteed within the tolerance required by the measurement. This can mean multi-day stability of less than a micron. The software that runs on these systems must be flexible enough to allow multiple product configurations, while maintaining the simplicity required by plant operators. The final requirement is to have systems that can withstand the environmental conditions of the measurement. This might mean qualification in explosive environments, or operation in hot, wet or dusty environments. All of these requirements can put restrictions on not only the voltage of electronic circuitry used, but also the wavelength and optical power used for the transmitter and receiver. The application of terahertz systems to online process control presents unique challenges that not only effect the physical design of the system, but can also effect the choices made on the terahertz technology itself.
Iwaya, Katsuya; Shimizu, Ryota; Hashizume, Tomihiro; Hitosugi, Taro
2011-08-01
We designed and constructed an effective vibration isolation system for stable scanning tunneling microscopy measurements using a separate foundation and two vibration isolation stages (i.e., a combination of passive and active vibration isolation dampers). Systematic analyses of vibration data along the horizontal and vertical directions are present, including the vibration transfer functions of each stage and the overall vibration isolation system. To demonstrate the performance of the system, tunneling current noise measurements are conducted with and without the vibration isolation. Combining passive and active vibration isolation dampers successfully removes most of the vibration noise in the tunneling current up to 100 Hz. These comprehensive vibration noise data, along with details of the entire system, can be used to establish a clear guideline for building an effective vibration isolation system for various scanning probe microscopes and electron microscopes.
NASA Astrophysics Data System (ADS)
Yunus, Salmi Mohd; Johari, Azril Dahari; Husin, Shuib
2017-12-01
Investigation on the effect of Thermally Growth Oxides (TGO) on the adhesion strength for thermal barrier coating (TBC) was carried out. The TBC under studied was the multilayer systems which consist of NiCrAlY bond coat and YSZ/LZ ceramic coating deposited on Ni-based superalloy substrates. The development of thermally growth oxides (TGO) for both TBC systems after isothermal heat treatment was measured. Isothermal heat treatment was carried out at 1100 ˚C for 100 hours to age the samples. ASTM D4541: Standard Test Method for Pull-off Strength of Coatings using Portable Adhesion Tester was used to measure the adhesion strength of both TBC systems before and after heat treatment. The effect of the developed TGO on the measured adhesion strength was examined and correlation between them was established individually for both TBC systems. The failure mechanism of the both system was also identified; either cohesive or adhesive or the combination of both. The results showed that TGO has more than 50% from the bond coat layer for rare-earth LZ system compared to the typical YSZ system, which was less than 10 % from the bond coat layer. This leads to the lower adhesion strength of rare-earth LZ coating system compared to typical YSZ system. Failure mechanism during the pull-off test also was found to be different for both TBC systems. The typical YSZ system experienced cohesive failure whereas the rare-earth LZ system experienced the combination of cohesive and adhesive failure.
Small total dose measurement system for SDS-1
NASA Astrophysics Data System (ADS)
Kimoto, Yugo; Satoh, Yohei; Tachihara, Hiroshi
2009-11-01
The Japanese Aerospace Exploration Agency (JAXA) uses monitors on board satellites to measure and record in-flight data on ionization effects in space. A compact, total dose measurement system for the small satellite (SDS-1) was developed based on the previous system for measuring total ionizing dose effects. Especially, the sensor for SDS-1 is quite smaller than the sensor for SOHLA-1, which is presented in the last year. The sensor is 8 mm wide×3 mm high×19 mm long and weighs approximately 4 g with 500 mm its wire harness. Eight pin LCC RADFET and temperature sensor are arranged on it. Seven sensors are arranged on some components inside the SDS-1. One of the sensors is arranged on a printed board in advanced microprocessing in-ORBIT experiment equipment (AMI). The AMI demonstrate 320 MIPS microprocessor and DC-DC converter for space. The absorbed dose at the points where the sensors are arranged was evaluated before flight and will be compared with resulting flight data.
Mutual Coupling and Compensation in FMCW MIMO Radar Systems
NASA Astrophysics Data System (ADS)
Schmid, Christian M.; Feger, Reinhard; Wagner, Christoph; Stelzer, Andreas
2011-09-01
This paper deals with mutual coupling, its effects and the compensation thereof in frequency-modulated continuous-wave (FMCW) multiple-input multiple-output (MIMO) array radar systems. Starting with a signal model we introduce mutual coupling and its primary sources in FMCW MIMO systems. We also give a worst-case boundary of the effects that mutual coupling can have on the side lobe level of an array. A method of dealing with and compensating for these effects is covered in this paper and verified by measurements from a 77-GHz FMCW radar system.
Overview of HPM Effects in Electronics
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holloway, Michael A.
2012-06-04
The following presentation contains an overview of HPM effects in modern electronics. HPM effects can be categorized into two basic level of effects, which are damaging and non-damaging. Damaging effects include junction breakdowns, dielectric breakdowns, and latch-up. These types of effects render a system inoperable until repaired. With non-damaging effects, HPM signals couple to into system components generating circuit responses that can overwhelm normal operation. Non-damaging effects can temporarily render a system inoperable or cause a system to lock and require a restart. Since modern systems are so complex, fundamental mechanisms of upset in circuit primitives are studied. All topicsmore » covered and all figured contained within are found in open literature. All data plots presented were obtained from experimental measurements conducted at the University of Maryland College Park and are also found in the open literature.« less
Simulation and measurement of nonlinear behavior in a high-power test cell.
Harvey, Gerald; Gachagan, Anthony
2011-04-01
High-power ultrasound has many diverse uses in process applications in industries ranging from food to pharmaceutical. Because cavitation is frequently a desirable effect within many high-power, low-frequency systems, these systems are commonly expected to feature highly nonlinear acoustic propagation because of the high input levels employed. This generation of harmonics significantly alters the field profile compared with that of a linear system, making accurate field modeling difficult. However, when the short propagation distances involved are considered, it is not unreasonable to assume that these systems may remain largely linear until the onset of cavitation, in terms of classical acoustic propagation. The purpose of this paper is to investigate the possible nonlinear effects within such systems before the onset of cavitation. A theoretical description of nonlinear propagation will be presented and the merits of common analytical models will be discussed. Following this, a numerical model of nonlinearity will be outlined and the advantages it presents for representing nonlinear effects in bounded fields will be discussed. Next, the driving equipment and transducers will be evaluated for linearity to disengage any effects from those formed in the transmission load. Finally, the linearity of the system will be measured using an acoustic hydrophone and compared with finite element analysis to confirm that nonlinear effects are not prevalent in such systems at the onset of cavitation. © 2011 IEEE
Observation of a superfluid Hall effect
Jiménez-García, Karina; Williams, Ross A.; Beeler, Matthew C.; Perry, Abigail R.; Phillips, William D.; Spielman, Ian B.
2012-01-01
Measurement techniques based upon the Hall effect are invaluable tools in condensed-matter physics. When an electric current flows perpendicular to a magnetic field, a Hall voltage develops in the direction transverse to both the current and the field. In semiconductors, this behavior is routinely used to measure the density and charge of the current carriers (electrons in conduction bands or holes in valence bands)—internal properties of the system that are not accessible from measurements of the conventional resistance. For strongly interacting electron systems, whose behavior can be very different from the free electron gas, the Hall effect’s sensitivity to internal properties makes it a powerful tool; indeed, the quantum Hall effects are named after the tool by which they are most distinctly measured instead of the physics from which the phenomena originate. Here we report the first observation of a Hall effect in an ultracold gas of neutral atoms, revealed by measuring a Bose–Einstein condensate’s transport properties perpendicular to a synthetic magnetic field. Our observations in this vortex-free superfluid are in good agreement with hydrodynamic predictions, demonstrating that the system’s global irrotationality influences this superfluid Hall signal. PMID:22699494
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadmack, M. R.; Kowalczyk, J. M. D.; Lienert, B. R.
2013-06-15
An amplitude and phase compensation system has been developed and tested at the University of Hawai'i for the optimization of the RF drive system to the Mark V free-electron laser. Temporal uniformity of the RF drive is essential to the generation of an electron beam suitable for optimal free-electron laser performance and the operation of an inverse Compton scattering x-ray source. The design of the RF measurement and compensation system is described in detail and the results of RF phase compensation are presented. Performance of the free-electron laser was evaluated by comparing the measured effects of phase compensation with themore » results of a computer simulation. Finally, preliminary results are presented for the effects of amplitude compensation on the performance of the complete system.« less
The ventral hippocampi of male, Fischer-344 rats were implanted with microdialysis probes and the effects of systemically administered kainic acid (KA) (8 mg/kg, s.c.) on the in vivo release of amino acids were measured for four hours after administration. n order to measure GABA...
Field Evaluation of Open System Chambers for Measuring Whole Canopy Gas Exchanges
USDA-ARS?s Scientific Manuscript database
The ability to monitor whole canopy CO2 and H2O fluxes of crop plants in the field is needed for many research efforts ranging from plant breeding to the study of Climate Change effects on crops. Four portable, transparent, open system chambers for measuring canopy gas exchanges were field tested on...
ERIC Educational Resources Information Center
Dix, Yvette Ellsworth
2013-01-01
The objective of this quasi-experimental quantitative study was to determine if the use of a student response system, combined with an interactive whiteboard, led to increased student achievement in mathematics within a fifth grade classroom as measured by a district benchmark assessment and the annual Arizona Instrument to Measure Standards…
ERIC Educational Resources Information Center
Lenkeit, Jenny; Caro, Daniel H.
2014-01-01
Reports of international large-scale assessments tend to evaluate and compare education system performance based on absolute scores. And policymakers refer to high-performing and economically prosperous education systems to enhance their own systemic features. But socioeconomic differences between systems compromise the plausibility of those…
Latent effects decision analysis
Cooper, J Arlin [Albuquerque, NM; Werner, Paul W [Albuquerque, NM
2004-08-24
Latent effects on a system are broken down into components ranging from those far removed in time from the system under study (latent) to those which closely effect changes in the system. Each component is provided with weighted inputs either by a user or from outputs of other components. A non-linear mathematical process known as `soft aggregation` is performed on the inputs to each component to provide information relating to the component. This information is combined in decreasing order of latency to the system to provide a quantifiable measure of an attribute of a system (e.g., safety) or to test hypotheses (e.g., for forensic deduction or decisions about various system design options).
A Method to Determine the Impact of Patient-Centered Care Interventions in Primary Care
Daaleman, Timothy P.; Shea, Christopher M.; Halladay, Jacqueline; Reed, David
2014-01-01
INTRODUCTION The implementation of patient-centered care (PCC) innovations continues to be poorly understood. We used the implementation effectiveness framework to pilot a method for measuring the impact of a PCC innovation in primary care practices. METHODS We analyzed data from a prior study that assessed the implementation of an electronic geriatric quality-of-life (QOL) module in 3 primary care practices in central North Carolina in 2011–12. Patients responded to the items and the subsequent patient-provider encounter was coded using the Roter Interaction Analysis System (RIAS) system. We developed an implementation effectiveness measure specific to the QOL module (i.e., frequency of usage during the encounter) using RIAS and then tested if there were differences with RIAS codes using analysis of variance. RESULTS A total of 60 patient-provider encounters examined differences in the uptake of the QOL module (i.e., implementation-effectiveness measure) with the frequency of RIAS codes during the encounter (i.e., patient-centeredness measure). There was a significant association between the effectiveness measure and patient-centered RIAS codes. CONCLUSION The concept of implementation effectiveness provided a useful framework determine the impact of a PCC innovation. PRACTICE IMPLICATIONS A method that captures real-time interactions between patients and care staff over time can meaningfully evaluate PCC innovations. PMID:25269410
Soil Erodibility Parameters Under Various Cropping Systems of Maize
NASA Astrophysics Data System (ADS)
van Dijk, P. M.; van der Zijp, M.; Kwaad, F. J. P. M.
1996-08-01
For four years, runoff and soil loss from seven cropping systems of fodder maize have been measured on experimental plots under natural and simulated rainfall. Besides runoff and soil loss, several variables have also been measured, including rainfall kinetic energy, degree of slaking, surface roughness, aggregate stability, soil moisture content, crop cover, shear strength and topsoil porosity. These variables explain a large part of the variance in measured runoff, soil loss and splash erosion under the various cropping systems. The following conclusions were drawn from the erosion measurements on the experimental plots (these conclusions apply to the spatial level at which the measurements were carried out). (1) Soil tillage after maize harvest strongly reduced surface runoff and soil loss during the winter; sowing of winter rye further reduced winter erosion, though the difference with a merely tilled soil is small. (2) During spring and the growing season, soil loss is reduced strongly if the soil surface is partly covered by plant residues; the presence of plant residue on the surface appeared to be essential in achieving erosion reduction in summer. (3) Soil loss reductions were much higher than runoff reductions; significant runoff reduction is only achieved by the straw system having flat-lying, non-fixed plant residue on the soil surface; the other systems, though effective in reducing soil loss, were not effective in reducing runoff.
Summary Report of Mission Acceleration Measurement for STS-87: Launched November 19, 1997
NASA Technical Reports Server (NTRS)
Rogers, Melissa J. B.; Hrovat, Kenneth; McPherson, Kevin; DeLombard, Richard; Reckart, Timothy
1999-01-01
Two accelerometer systems, the Orbital Acceleration Research Experiment and the Space Acceleration Measurement System, were used to measure and record the microgravity environment of the Orbiter Columbia during the STS-87 mission in November-December 1997. Data from two separate Space Acceleration Measurement System units were telemetered to the ground during the mission and data plots were displayed for investigators of the Fourth United States Microgravity Payload experiments in near real-time using the World Wide Web. Plots generated using Orbital Acceleration Research Experiment data (telemetered to the ground using a tape delay) were provided to the investigators using the World Wide Web approximately twelve hours after data recording. Disturbances in the microgravity environment as recorded by these instruments are grouped by source type: Orbiter systems, on-board activities, payload operations, and unknown sources. The environment related to the Ku-band antenna dither, Orbiter structural modes, attitude deadband collapses, water dump operations, crew sleep, and crew exercise was comparable to the effects of these sources on previous Orbiter missions. Disturbances related to operations of the Isothermal Dendritic Growth Experiment and Space Acceleration Measurement Systems that were not observed on previous missions are detailed. The effects of Orbiter cabin and airlock depressurization and extravehicular activities are also reported for the first time. A set of data plots representing the entire mission is included in the CD-ROM version of this report.
Zhu, Kewu; Ng, Wai Kiong; Shen, Shoucang; Tan, Reginald B H; Heng, Paul W S
2008-11-01
To develop a device for simultaneous measurement of particle aerodynamic diameter and electrostatic charge of inhalation aerosols. An integrated system consisting of an add-on charge measurement device and a liquid impinger was developed to simultaneously determine particle aerodynamic diameter and electrostatic charge. The accuracy in charge measurement and fine particle fraction characterization of the new system was evaluated. The integrated system was then applied to analyze the electrostatic charges of a DPI formulation composed of salbutamol sulphate-Inhalac 230 dispersed using a Rotahaler. The charge measurement accuracy was comparable with the Faraday cage method, and incorporation of the charge measurement module had no effect on the performance of the liquid impinger. Salbutamol sulphate carried negative charges while the net charge of Inhalac 230 and un-dispersed salbutamol sulphate was found to be positive after being aerosolized from the inhaler. The instantaneous current signal was strong with small noise to signal ratio, and good reproducibility of charge to mass ratio was obtained for the DPI system investigated. A system for simultaneously measuring particle aerodynamic diameter and aerosol electrostatic charges has been developed, and the system provides a non-intrusive and reliable electrostatic charge characterization method for inhalation dosage forms.
Further comparison of MODTRAN 5 to measured data in the UV band
NASA Astrophysics Data System (ADS)
Smith, Leon; Richardson, Mark; Ayling, Richard; Barlow, Nick
2014-10-01
The ability to accurately model background radiation from the sun is important in understanding the operation of missile systems with ultraviolet (UV) guard channels. In theory a missile system's UV channel detects a target's silhouette, caused by its `negative contrast' with respect to background UV radiation. The variation in background levels of UV will therefore have an effect on the operability of a missile system that utilises a UV channel. In this paper an update on the measurement and comparison of background UV-A radiation to data produced by Moderate Resolution Atmospheric Transmission 5 (MODTRAN®5) is given. In the past surface flux and radiance data calculated using MODTRAN®5 has been compared to data from the World Ozone and Ultraviolet Data Centre (WOUDC) archive, and measurements taken by the author at the Defence Academy of the UK. With the aid of spectral measurement equipment, new measurements have been made and compared with the radiance profiles produced by MODTRAN®5, including measurements made throughout both winter and summer months. Also discussed are the effects of scattering and absorption by different cloud types on the amount of radiation observed at the Earth's surface.
Risk measures for power failures in transmission systems
NASA Astrophysics Data System (ADS)
Cassidy, Alex; Feinstein, Zachary; Nehorai, Arye
2016-11-01
We present a novel framework for evaluating the risk of failures in power transmission systems. We use the concept of systemic risk measures from the financial mathematics literature with models of power system failures in order to quantify the risk of the entire power system for design and comparative purposes. The proposed risk measures provide the collection of capacity vectors for the components in the system that lead to acceptable outcomes. Keys to the formulation of our measures of risk are two elements: a model of system behavior that provides the (distribution of) outcomes based on component capacities and an acceptability criterion that determines whether a (random) outcome is acceptable from an aggregated point of view. We examine the effects of altering the line capacities on energy not served under a variety of networks, flow manipulation methods, load shedding schemes, and load profiles using Monte Carlo simulations. Our results provide a quantitative comparison of the performance of these schemes, measured by the required line capacity. These results provide more complete descriptions of the risks of power failures than the previous, one-dimensional metrics.
Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui
2015-05-01
The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.
Green, Dido; Wilson, Peter H
2012-01-01
To evaluate the feasibility and therapeutic effect of engaging children of differing neuromotor and cognitive ability in a virtual reality (VR) tabletop workspace designed to improve upper-limb function. Single-subject experimental design with multiple baselines was employed. Four children with hemiplegia participated in VR-based training between nine and 19, 30-minute sessions, over three-four weeks. Outcomes were assessed from the perspective of the International Classification of Functioning, Disability and Health; considering body function, activity performance and participation. Upper-limb performance was assessed using system-measured variables (speed, trajectory and accuracy) and standardized tests. Trend analyses were employed to determine trends on system variables between baseline phase and treatment phases. Standardised measures were compared between pre- and post-training. Two children made progress across system variables with some translation to daily activities. Performance of the other two children was more variable, however, they engaged positively with the system by the end of the treatment phase. The VR (RE-ACTION) system shows promise as an engaging rehabilitation tool to improve upper-limb function of children with hemiplegia, across ability levels. Trade-offs between kinematic variables should be considered when measuring improvements in movement skill. Larger trials are warranted to evaluate effects of augmented feedback, intensity and duration of training, and interface type to optimise the system's effectiveness.
Marwani, Hadi M; Lowry, Mark; Keating, Patrick; Warner, Isiah M; Cook, Robert L
2007-11-01
This study introduces a newly developed frequency segmentation and recombination method for frequency-domain fluorescence lifetime measurements to address the effects of changing fractional contributions over time and minimize the effects of photobleaching within multi-component systems. Frequency segmentation and recombination experiments were evaluated using a two component system consisting of fluorescein and rhodamine B. Comparison of experimental data collected in traditional and segmented fashion with simulated data, generated using different changing fractional contributions, demonstrated the validity of the technique. Frequency segmentation and recombination was also applied to a more complex system consisting of pyrene with Suwannee River fulvic acid reference and was shown to improve recovered lifetimes and fractional intensity contributions. It was observed that photobleaching in both systems led to errors in recovered lifetimes which can complicate the interpretation of lifetime results. Results showed clear evidence that the frequency segmentation and recombination method reduced errors resulting from a changing fractional contribution in a multi-component system, and allowed photobleaching issues to be addressed by commercially available instrumentation.
NASA Technical Reports Server (NTRS)
Klein, R. H.; Mcruer, D. T.; Weir, D.
1975-01-01
A maneuver complex and related performance measures used to evaluate driver/vehicle system responses as effected by variations in the directional response characteristics of passenger cars are described. The complex consists of normal and emergency maneuvers (including random and discrete disturbances) which, taken as a whole, represent all classes of steering functions and all modes of driver response behavior. Measures of driver/vehicle system response and performance in regulation tasks included direct describing function measurements and rms yaw velocity. In transient maneuvers, measures such as steering activity and cone strikes were used.
Transient Plume Model Testing Using LADEE Spacecraft Attitude Control System Operations
NASA Technical Reports Server (NTRS)
Woronowicz, Michael
2011-01-01
We have learned it is conceivable that the Neutral Mass Spectrometer on board the Lunarr Atmosphere Dust Environment Explorer (LADEE) could measure gases from surface-reflected Attitude Control System (ACS) thruster plume. At minimum altitude, the measurement would be maximized, and gravitational influence minimized ("short" time-of-flight (TOF) situation) Could use to verify aspects of thruster plume modeling Model the transient disturbance to NMS measurements due to ACS gases reflected from lunar surface Observe evolution of various model characteristics as measured by NMS Species magnitudes, TOF measurements, angular distribution, species separation effects
Absorbed dose measurement in low temperature samples:. comparative methods using simulated material
NASA Astrophysics Data System (ADS)
Garcia, Ruth; Harris, Anthony; Winters, Martell; Howard, Betty; Mellor, Paul; Patil, Deepak; Meiner, Jason
2004-09-01
There is a growing need to reliably measure absorbed dose in low temperature samples, especially in the pharmaceutical and tissue banking industries. All dosimetry systems commonly used in the irradiation industry are temperature sensitive. Radiation of low temperature samples, such as those packaged with dry ice, must therefore take these dosimeter temperature effects into consideration. This paper will suggest a method to accurately deliver an absorbed radiation dose using dosimetry techniques designed to abrogate the skewing effects of low temperature environments on existing dosimetry systems.
NASA Technical Reports Server (NTRS)
Mathews, Charles W; Talmage, Donald B; Whitten, James B
1951-01-01
The longitudinal stability and control characteristics of a B-29 airplane have been measured with a control surface booster incorporated in the elevator-control system. The measurements were obtained with the booster operating to provide various control-force gradients and various maximum rates of control motion. Results are presented which show the effect of these booster parameters on the handling qualities of the test airplane.
NASA Technical Reports Server (NTRS)
Vlajinac, M.; Stephens, T.; Gilliam, G.; Pertsas, N.
1972-01-01
Results of subsonic and supersonic wind-tunnel tests with a magnetic balance and suspension system on a family of bulbous based cone configurations are presented. At subsonic speeds the base flow and separation characteristics of these configurations is shown to have a pronounced effect on the static data. Results obtained with the presence of a dummy sting are compared with support interference free data. Support interference is shown to have a substantial effect on the measured aerodynamic coefficient.
Estimation of Aerosol Direct Radiative Effects from Satellite and In Situ Measurements
NASA Technical Reports Server (NTRS)
Bergstrom, Robert W.; Russell, Philip B.; Schmid, Beat; Redemann, Jens; McIntosh, Dawn
2000-01-01
Ames researchers have combined measurements from satellite, aircraft, and the surface to estimate the effect of airborne particles (aerosols) on the solar radiation over the North Atlantic region. These aerosols (which come from both natural and pollution sources) can reflect solar radiation, causing a cooling effect that opposes the warming caused by carbon dioxide. Recently, increased attention has been paid to aerosol effects to better understand the Earth climate system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shishkov, L. K., E-mail: slk@vver.kiae.ru; Zizin, M. N., E-mail: zizin_m@mail.ru
The process of formation of an asymptotic distribution of the neutron flux density in the reactor systems after introducing different negative reactivities is considered. The impact of two factors after the reactivity introduction is evaluated: (1) nonuniformity of perturbation of core properties, on one hand, and (2) a sharp reduction in the density of prompt neutrons, which prevents the appearance of new delayed neutron emitters distributed in accordance with the “new” prompt neutron distribution, on the other hand. The results of calculations show that the errors of measuring the scram system effectiveness using the method of inverse solution of themore » kinetics equation are caused by the fact that, after the negative reactivity insertion, the sources of prompt and delayed neutrons have different spatial distributions. In the case of high negative reactivities, this difference remains while the system still has neutrons, which can be measured.« less
NASA Astrophysics Data System (ADS)
Li, Gang; Wang, Tao; Ye, Ming-Yong; Song, He-Shan
2015-12-01
Weak measurement [Y. Aharonov, D.Z. Albert, L. Vaidman, Phys. Rev. Lett. 60, 1351 (1988); C. Simon, E.S. Polzik, Phys. Rev. A 83, 040101(R) (2011)] combined with quantum delayed-choice experiment that use Controlled Hadamard gate instead of Hadamard gate in quantum networks give rise to a surprising amplification effect, i.e., counterintuitive negative amplification effect. We show that this effect is caused by the wave and particle behaviours of the system, and it can't be explained by a semiclassical wave theory [D. Suter, Phys. Rev. A 51, 45 (1995); J.C. Howell, D.J. Starling, P.B. Dixon, P.K. Vudyasetu, A.N. Jordan, Phys. Rev. A 81, 033813 (2010); N. Brunner, A. Acín, D. Collins, N. Gisin, V. Scarani, Phys. Rev. Lett. 91, 180402 (2003)] and by the statistical feature of preselection and postselection with disturbance [C. Ferrie, J. Combes, Phys. Rev. Lett. 113, 120404 (2014)], due to the entanglement of the system and the ancilla in Controlled Hadamard gate. The generation mechanism with wave-particle duality in quantum mechanics lead us to a scheme for implementation of weak measurement in optomechanical system.
Spacecraft contamination programs within the Air Force Systems Command Laboratories
NASA Technical Reports Server (NTRS)
Murad, Edmond
1990-01-01
Spacecraft contamination programs exist in five independent AFSC organizations: Geophysics Laboratory (GL), Arnold Engineering and Development Center (AEDC), Rome Air Development Center (RADC/OSCE), Wright Research and Development Center (MLBT), Armament Laboratory (ATL/SAI), and Space Systems Division (SSD/OL-AW). In addition, a sizable program exists at Aerospace Corp. These programs are complementary, each effort addressing a specific area of expertise: GL's effort is aimed at addressing the effects of on-orbit contamination; AEDC's effort is aimed at ground simulation and measurement of optical contamination; RADC's effort addresses the accumulation, measurement, and removal of contamination on large optics; MLBT's effort is aimed at understanding the effect of contamination on materials; ATL's effort is aimed at understanding the effect of plume contamination on systems; SSD's effort is confined to the integration of some contamination experiments sponsored by SSD/CLT; and Aerospace Corp.'s effort is aimed at supporting the needs of the using System Program Offices (SPO) in specific areas, such as contamination during ground handling, ascent phase, laboratory measurements aimed at understanding on-orbit contamination, and mass loss and mass gain in on-orbit operations. These programs are described in some detail, with emphasis on GL's program.
Summary Report of Mission Acceleration Measurements for STS-78. Launched June 20, 1996
NASA Technical Reports Server (NTRS)
Hakimzadeh, Roshanak; Hrovat, Kenneth; McPherson, Kevin M.; Moskowitz, Milton E.; Rogers, Melissa J. B.
1997-01-01
The microgravity environment of the Space Shuttle Columbia was measured during the STS-78 mission using accelerometers from three different instruments: the Orbital Acceleration Research Experiment, the Space Acceleration Measurement System and the Microgravity Measurement Assembly. The quasi-steady environment was also calculated in near real-time during the mission by the Microgravity Analysis Workstation. The Orbital Acceleration Research Experiment provided investigators with real-time quasi-steady acceleration measurements. The Space Acceleration Measurement System recorded higher frequency data on-board for post-mission analysis. The Microgravity Measurement Assembly provided investigators with real-time quasi-steady and higher frequency acceleration measurements. The Microgravity Analysis Workstation provided calculation of the quasi-steady environment. This calculation was presented to the science teams in real-time during the mission. The microgravity environment related to several different Orbiter, crew and experiment operations is presented and interpreted in this report. A radiator deploy, the Flight Control System checkout, and a vernier reaction control system reboost demonstration had minimal effects on the acceleration environment, with excitation of frequencies in the 0.01 to 10 Hz range. Flash Evaporator System venting had no noticeable effect on the environment while supply and waste water dumps caused excursions of 2 x lO(exp -6) to 4 x 10(exp -6) g in the Y(sub b) and Z(sub b) directions. Crew sleep and ergometer exercise periods can be clearly seen in the acceleration data, as expected. Accelerations related to the two Life Science Laboratory Equipment Refrigerator/Freezers were apparent in the data as are accelerations caused by the Johnson Space Center Projects Centrifuge. As on previous microgravity missions, several signals are present in the acceleration data for which a source has not been identified. The causes of these accelerations are under investigation.
Motion effects in multistatic millimeter-wave imaging systems
NASA Astrophysics Data System (ADS)
Schiessl, Andreas; Ahmed, Sherif Sayed; Schmidt, Lorenz-Peter
2013-10-01
At airport security checkpoints, authorities are demanding improved personnel screening devices for increased security. Active mm-wave imaging systems deliver the high quality images needed for reliable automatic detection of hidden threats. As mm-wave imaging systems assume static scenarios, motion effects caused by movement of persons during the screening procedure can degrade image quality, so very short measurement time is required. Multistatic imaging array designs and fully electronic scanning in combination with digital beamforming offer short measurement time together with high resolution and high image dynamic range, which are critical parameters for imaging systems used for passenger screening. In this paper, operational principles of such systems are explained, and the performance of the imaging systems with respect to motion within the scenarios is demonstrated using mm-wave images of different test objects and standing as well as moving persons. Electronic microwave imaging systems using multistatic sparse arrays are suitable for next generation screening systems, which will support on the move screening of passengers.
Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi
2017-11-01
This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Sun, Wen-Yang; Wang, Dong; Fang, Bao-Long; Shi, Jia-Dong; Ye, Liu
2018-06-01
In this letter, we mainly investigate how to enhance the damaged quantum entanglement under an open Dirac system with the Hawking effect within Schwarzschild space-time. We consider that particle A held by Alice undergoes generalized amplitude damping noise in a flat space-time, and that another particle B by Bob entangled with A is under a Schwarzschild space-time. Subsequently, we put forward a physical scheme to recover the damaged quantum entanglement by prior weak measurement on subsystem A before the interaction with the decoherence noise followed by post-measurement filtering operation. The results indicate that our scheme can effectively recover the damaged quantum entanglement affected by the Hawking effect and the noisy channel. Thus, our work might be beneficial to understand the dynamic behavior of the quantum state and recover the damaged quantum entanglement with open Dirac systems under the Hawking effect in the background of a Schwarzschild black hole.
ERIC Educational Resources Information Center
Ha, Wei
2016-01-01
This paper examines the effects of roommates on students' academic outcomes exploiting the randomized roommate assignment system at a selective Chinese university. Unlike earlier studies that could not measure students' academic quality precisely, this paper makes two important improvements in measuring their English proficiency and overall…
NASA Astrophysics Data System (ADS)
Zhang, Jiankun; Li, Ziyang; Dang, Anhong
2018-06-01
It has been recntly shown that polarization state of propagation beam would suffer from polarization fluctuations due to the detrimental effects of atmospheric turbulence. This paper studies the performance of wireless optical communication (WOC) systems in the presence of polarization effect of atmosphere. We categorize the atmospheric polarization effect into polarization rotation, polarization-dependent power loss, and phase shift effect, with each effect described and modeled with the help of polarization-coherence theory and the extended Huygens-Fresnelprinciple. The channel matrices are derived to measure the cross-polarization interference of the system. Signal-to-noise ratio and bit error rate for polarization multiplexing system and polarization modulation system are obtained to assess the viability using the approach of M turbulence model. Monte Carlo simulation results show the performance of polarization based WOC systems to be degraded by atmospheric polarization effect, which could be evaluated precisely using the proposed model with given turbulent strengths.
Model-based quantification of image quality
NASA Technical Reports Server (NTRS)
Hazra, Rajeeb; Miller, Keith W.; Park, Stephen K.
1989-01-01
In 1982, Park and Schowengerdt published an end-to-end analysis of a digital imaging system quantifying three principal degradation components: (1) image blur - blurring caused by the acquisition system, (2) aliasing - caused by insufficient sampling, and (3) reconstruction blur - blurring caused by the imperfect interpolative reconstruction. This analysis, which measures degradation as the square of the radiometric error, includes the sample-scene phase as an explicit random parameter and characterizes the image degradation caused by imperfect acquisition and reconstruction together with the effects of undersampling and random sample-scene phases. In a recent paper Mitchell and Netravelli displayed the visual effects of the above mentioned degradations and presented subjective analysis about their relative importance in determining image quality. The primary aim of the research is to use the analysis of Park and Schowengerdt to correlate their mathematical criteria for measuring image degradations with subjective visual criteria. Insight gained from this research can be exploited in the end-to-end design of optical systems, so that system parameters (transfer functions of the acquisition and display systems) can be designed relative to each other, to obtain the best possible results using quantitative measurements.
Gyroscope-reduced inertial navigation system for flight vehicle motion estimation
NASA Astrophysics Data System (ADS)
Wang, Xin; Xiao, Lu
2017-01-01
In this paper, a novel configuration of strategically distributed accelerometer sensors with the aid of one gyro to infer a flight vehicle's angular motion is presented. The MEMS accelerometer and gyro sensors are integrated to form a gyroscope-reduced inertial measurement unit (GR-IMU). The motivation for gyro aided accelerometers array is to have direct measurements of angular rates, which is an improvement to the traditional gyroscope-free inertial system that employs only direct measurements of specific force. Some technical issues regarding error calibration in accelerometers and gyro in GR-IMU are put forward. The GR-IMU based inertial navigation system can be used to find a complete attitude solution for flight vehicle motion estimation. Results of numerical simulation are given to illustrate the effectiveness of the proposed configuration. The gyroscope-reduced inertial navigation system based on distributed accelerometer sensors can be developed into a cost effective solution for a fast reaction, MEMS based motion capture system. Future work will include the aid from external navigation references (e.g. GPS) to improve long time mission performance.
Development of limb volume measuring system
NASA Technical Reports Server (NTRS)
Bhagat, P. K.; Kadaba, P. K.
1983-01-01
The mechanisms underlying the reductions in orthostatic tolerance associated with weightlessness are not well established. Contradictory results from measurements of leg volume changes suggest that altered venomotor tone and reduced blood flow may not be the only contributors to orthostatic intolerance. It is felt that a more accurate limb volume system which is insensitive to environmental factors will aid in better quantification of the hemodynamics of the leg. Of the varous limb volume techniques presently available, the ultrasonic limb volume system has proven to be the best choice. The system as described herein is free from environmental effects, safe, simple to operate and causes negligible radio frequency interference problems. The segmental ultrasonic ultrasonic plethysmograph is expected to provide a better measurement of limb volume change since it is based on cross-sectional area measurements.
Outcomes measurement in hospitals: can the system change the organization?
Linder, J C
1992-01-01
The U.S. health care industry is in crisis--a crisis of accountability. Many believe that improved information, especially outcomes information, is at least part of the solution. If this assessment is accurate, outcomes measurement could offer a powerful opportunity to help mold our dysfunctional health care machinery into an effective infrastructure. This article explores whether implementing an outcomes measurement system in a hospital compels this kind of change. It examines the experiences of 31 hospitals that implemented a market-leading outcomes measurement system. Despite its potential, MedisGroups did not compel important improvements in hospitals' quality of care or their internal practices. Hospitals found it particularly difficult to maintain momentum throughout implementation and to structure the system as a supporting tool, rather than a driving influence, in their pursuit of operating improvements.
Svevo-Cianci, Kimberly A; Hart, Stuart N; Rubinson, Claude
2010-01-01
(1) To identify which United Nations Convention on the Rights of the Child (CRC) recommended child protection (CP) measures, such as policy, reporting systems, and services for child abuse and neglect (CAN) victims, individually or in combination, were most important in establishing a basic level of child protection in 42 countries; and (2) to assess whether these measures were necessary or sufficient to achieve basic child protection in developing and industrialized countries. Child protection and/or rights expert respondents from 42 countries completed a questionnaire on CRC Article 19 (CRC19) required CP measures implementation and rated their country's effectiveness in implementation, the current level of effectiveness of child protection, and the relevance of improvements in child protection since the CRC was adopted in 1989. Information from the Committee on the Rights of the Child Concluding Observations, as well as UNICEF and WHO indicators on child health and protection issues were used to check and supplement responses. Qualitative comparative analysis (QCA) was used to identify child protection measure implementation effectiveness. Results indicate that child protection judged as comparatively more successful among study countries is a result of having the following measures in place from two types of social programs: a CP infrastructure (legislation plus services) and at least one information-based intervention support program. Fourteen (33%) countries were determined to have established at least a basic CP system toward protection of children from violence and maltreatment. These countries reported having the three required elements described above. The study reinforces the need for governments to take a systems approach to child protection, including policy/legislation, information-based programs and social services, as well as professional training and public awareness raising. The top-ranked countries included: Australia, Bahrain, Belgium, Brazil, Canada, Estonia, Germany, Italy, Jordan, Lebanon, Malaysia, Republic of Korea, the Russian Federation, and the United Kingdom. Governments need to establish CP systems with multiple, well-integrated, effective CP measures as elaborated above, working with trained professionals and also raising public awareness to ensure successful protection for all children in every country. Partial measures are not effective. Further, in addition to establishing, implementing, and evaluating the effectiveness of professional interventions, the actual outcomes for children, not studied or reported on here, need to be the priority focus for child protection going forward. Copyright (c) 2009 Elsevier Ltd. All rights reserved.
Measuring physicians' trust: A scoping review with implications for public policy.
Wilk, Adam S; Platt, Jodyn E
2016-09-01
Increasingly, physicians are expected to work in productive, trusting relationships with other health system stakeholders to improve patient and system outcomes. A better understanding of physicians' trust is greatly needed. This study assesses the state of the literature on physicians' trust in patients, other health care providers, institutions, and data systems or technology, and identifies key themes, dimensions of trust considered, quantitative measures used, and opportunities for further development via a scoping review. Peer-reviewed, English-language research articles were identified for inclusion in this study based on systematic searches of the Ovid/Medline, Pubmed, Proquest, Scopus, Elsevier, and Web of Science databases. Search terms included "trust" along with "physician," "doctor," "primary care provider," "family practitioner," "family practice," "generalist," "general practitioner," "general practice," "internist," "internal medicine," or "health professional," and plausible variants. Among the relevant articles identified (n = 446), the vast majority focused on patient trust in physicians (81.2%). Among articles examining physicians' trust, rigorous investigations of trust are rare, narrowly focused, and imprecise in their discussion of trust. Robust investigations of the effects of trust or distrust-as opposed to trust's determinants-and studies using validated quantitative trust measures are particularly rare. Studies typically measured trust using the language of confidence, effective communication, or cooperation, rarely or never capturing other important dimensions of trust, such as fidelity, the trustee's reputation, social capital, vulnerability, and acceptance. Research employing new, validated measures of physicians' trust, especially trust in institutions, may be highly informative to health system leaders and policymakers seeking to hone and enhance tools for improving the effectiveness and efficiency of the health care system. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Davidson, Frederic M.; Field, Christopher T.; Sun, Xiaoli
1996-01-01
We report here the design and the performance measurements of the breadboard receiver of the Geoscience Laser Altimeter System (GLAS). The measured ranging accuracy was better than 2 cm and 10 cm for 5 ns and 30 ns wide received laser pulses under the expected received signal level, which agreed well with the theoretical analysis. The measured receiver sensitivity or the link margin was also consistent with the theory. The effects of the waveform digitizer sample rate and resolution were also measured.
Donovan, Preston; Chehreghanianzabi, Yasaman; Rathinam, Muruhan; Zustiak, Silviya Petrova
2016-01-01
The study of diffusion in macromolecular solutions is important in many biomedical applications such as separations, drug delivery, and cell encapsulation, and key for many biological processes such as protein assembly and interstitial transport. Not surprisingly, multiple models for the a-priori prediction of diffusion in macromolecular environments have been proposed. However, most models include parameters that are not readily measurable, are specific to the polymer-solute-solvent system, or are fitted and do not have a physical meaning. Here, for the first time, we develop a homogenization theory framework for the prediction of effective solute diffusivity in macromolecular environments based on physical parameters that are easily measurable and not specific to the macromolecule-solute-solvent system. Homogenization theory is useful for situations where knowledge of fine-scale parameters is used to predict bulk system behavior. As a first approximation, we focus on a model where the solute is subjected to obstructed diffusion via stationary spherical obstacles. We find that the homogenization theory results agree well with computationally more expensive Monte Carlo simulations. Moreover, the homogenization theory agrees with effective diffusivities of a solute in dilute and semi-dilute polymer solutions measured using fluorescence correlation spectroscopy. Lastly, we provide a mathematical formula for the effective diffusivity in terms of a non-dimensional and easily measurable geometric system parameter. PMID:26731550
Taber-Doughty, Teresa
2005-01-01
Three secondary age students with moderate intellectual disabilities learned to use the system of least prompts, a self-operated picture prompting system, and a self-operated auditory prompting system to use a copy machine and a debit machine. Both the effectiveness and efficiency of these prompting systems were compared. Additionally, student preference of instructional method was examined. The results demonstrated that each prompting system was effective and efficient with varying students when skill acquisition and duration of task performance were measured. All students demonstrated increased independence in completing both tasks. This study found that the preferred prompting systems were more effective in terms of both skill acquisition and duration for completing tasks for students.
Sensitivity of measurement-based purification processes to inner interactions
NASA Astrophysics Data System (ADS)
Militello, Benedetto; Napoli, Anna
2018-02-01
The sensitivity of a repeated measurement-based purification scheme to additional undesired couplings is analyzed, focusing on the very simple and archetypical system consisting of two two-level systems interacting with a repeatedly measured one. Several regimes are considered and in the strong coupling limit (i.e., when the coupling constant of the undesired interaction is very large) the occurrence of a quantum Zeno effect is proven to dramatically jeopardize the efficiency of the purification process.
ERIC Educational Resources Information Center
Moore, Richard W.; Chapman, Kenneth; Huber, Bettina; Shors, Mark
2013-01-01
A new federal initiative calls for a College Scorecard which will include a yet to be determined measure of graduate earnings. In this paper we examine the political context that drives this initiative and examine the nascent efforts of four states to develop statewide systems to measure the labor market outcomes of higher education. We propose…
NASA Astrophysics Data System (ADS)
Orłowska-Szostak, Maria; Orłowski, Ryszard
2017-11-01
The paper discusses some relevant aspects of the calibration of a computer model describing flows in the water supply system. The authors described an exemplary water supply system and used it as a practical illustration of calibration. A range of measures was discussed and applied, which improve the convergence and effective use of calculations in the calibration process and also the effect of such calibration which is the validity of the results obtained. Drawing up results of performed measurements, i.e. estimating pipe roughnesses, the authors performed using the genetic algorithm implementation of which is a software developed by Resan Labs company from Brazil.
NASA Technical Reports Server (NTRS)
Dantin, E. J.; Whitehurst, C. A.; Durbin, W. T.
1974-01-01
The history of the existing jetty system at Belle Pass was investigated to determine its past effect on the littoral currents and beach erosion. Present flow patterns and erosion rates were also studied, along with the prevailing recession rates of local beaches not influenced by the jetty system. Aerial photographs and maps were used in conjunction with periodic hydraulic measurements, ground observations, and physical measurements of beach erosion. A scale model was constructed to further the study of flow patterns and velocities. It is shown that the existing jetty has not adversely affected the coastline in the area; erosive processes have been retarded by the jetty and its companion groin. Future erosion patterns are predicted, and projected effects of the proposed jetty system are given.
Fiber-Optic Strain-Gage Tank Level Measurement System for Cryogenic Propellants
NASA Technical Reports Server (NTRS)
Figueroa, Fernando; Mitchell, Mark; Langford, Lester
2004-01-01
Measurement of tank level, particularly for cryogenic propellants, has proven to be a difficult problem. Current methods based on differential pressure, capacitance sensors, temperature sensors, etc.; do not provide sufficiently accurate or robust measurements, especially at run time. These methods are designed to measure tank-level, but when the fluids are in supercritical state, the liquid-gas interface disappears. Furthermore, there is a need for a non-intrusive measurement system; that is, the sensors should not require tank modifications and/or disturb the fluids. This paper describes a simple, but effective method to determine propellant mass by measuring very small deformations of the structure supporting the tank. Results of a laboratory study to validate the method, and experimental data from a deployed system are presented. A comparison with an existing differential pressure sensor shows that the strain gage system provides a much better quality signal across all regimes during an engine test. Experimental results also show that the use of fiber optic strain gages (FOSG) over classic foil strain gages extends the operation time (before the system becomes uncalibrated), and increases accuracy. Finally, a procedure is defined whereby measurements from the FOSG mounted on the tank supporting structure are compensated using measurements of a FOSG mounted on a reference plate and temperature measurements of the structure. Results describing the performance of a deployed system that measures tank level during propulsion tests are included.
NASA Astrophysics Data System (ADS)
Shrivastava, Akash; Mohanty, A. R.
2018-03-01
This paper proposes a model-based method to estimate single plane unbalance parameters (amplitude and phase angle) in a rotor using Kalman filter and recursive least square based input force estimation technique. Kalman filter based input force estimation technique requires state-space model and response measurements. A modified system equivalent reduction expansion process (SEREP) technique is employed to obtain a reduced-order model of the rotor system so that limited response measurements can be used. The method is demonstrated using numerical simulations on a rotor-disk-bearing system. Results are presented for different measurement sets including displacement, velocity, and rotational response. Effects of measurement noise level, filter parameters (process noise covariance and forgetting factor), and modeling error are also presented and it is observed that the unbalance parameter estimation is robust with respect to measurement noise.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klain, Kimberly L.
The behavior of symmetrical coupled-core systems has been extensively studied, yet there is a dearth of research on asymmetrical systems due to the increased complexity of the analysis of such systems. In this research, the multipoint kinetics method is applied to asymmetrical zeropower, subcritical, bare metal reactor systems. Existing research on asymmetrical reactor systems assumes symmetry in the neutronic coupling; however, it will be shown that this cannot always be assumed. Deep subcriticality adds another layer of complexity and requires modification of the multipoint kinetics equations to account for the effect of the external neutron source. A modified set ofmore » multipoint kinetics equations is derived with this in mind. Subsequently, the Rossi-alpha equations are derived for a two-region asymmetrical reactor system. The predictive capabilities of the radiation transport code MCNP6 for neutron noise experiments are shown in a comparison to the results of a series of Rossi-alpha measurements performed by J. Mihalczo utilizing a coupled set of symmetrical bare highly-enriched uranium (HEU) cylinders. The ptrac option within MCNP6 can generate time-tagged counts in a cell (list-mode data). The list-mode data can then be processed similarly to measured data to obtain values for system parameters such as the dual prompt neutron decay constants observable in a coupled system. The results from the ptrac simulations agree well with the historical measured values. A series of case studies are conducted to study the effects of geometrical asymmetry in the coupling between two bare metal HEU cylinders. While the coupling behavior of symmetrical systems has been reported on extensively, that of asymmetrical systems remains sparse. In particular, it appears that there has been no previous research in obtaining the coupling time constants for asymmetrically-coupled systems. The difficulty in observing such systems is due in part to the inability to determine the individual coupling coefficients from measurement: unlike the symmetrical cases, only the product of the values can be obtained. A method is proposed utilizing MCNP6 tally ratios to separate the coupling coefficients for such systems. This work provides insight into the behavior of asymmetrically-coupled systems as the separation distance between the two cores is changed and also as the asymmetry is increased. As the asymmetry increases, both the slower and the faster observable prompt neutron decay constants increase in magnitude. The coupling time constants are determined from the measured decay constants. As the separation distance increases, both coupling coefficients decrease as expected. Based on these findings, an effective computational method utilizing MCNP6 and the Rossialpha technique can be applied to the prediction of asymmetrical coupled system measurements.« less
NASA Technical Reports Server (NTRS)
Schweikhard, W. G.; Singnoi, W. N.
1985-01-01
A two axis thrust measuring system was analyzed by using a finite a element computer program to determine the sensitivities of the thrust vectoring nozzle system to misalignment of the load cells and applied loads, and the stiffness of the structural members. Three models were evaluated: (1) the basic measuring element and its internal calibration load cells; (2) the basic measuring element and its external load calibration equipment; and (3) the basic measuring element, external calibration load frame and the altitude facility support structure. Alignment of calibration loads was the greatest source of error for multiaxis thrust measuring systems. Uniform increases or decreases in stiffness of the members, which might be caused by the selection of the materials, have little effect on the accuracy of the measurements. It is found that the POLO-FINITE program is a viable tool for designing and analyzing multiaxis thrust measurement systems. The response of the test stand to step inputs that might be encountered with thrust vectoring tests was determined. The dynamic analysis show a potential problem for measuring the dynamic response characteristics of thrust vectoring systems because of the inherently light damping of the test stand.
Transmissivity testing of multilayer insulation at cryogenic temperatures
NASA Astrophysics Data System (ADS)
Johnson, W. L.; Van Dresar, N. T.; Chato, D. J.; Demers, J. R.
2017-09-01
The problem of degraded emissivity of thin films at low temperatures has been a long observed phenomena. Previous efforts at measuring properties have suggested that transmission of energy through the films may play a key role in the thermal performance of multilayer insulation systems at low temperatures. Similarly, recent testing on tank applied systems has suggested a radiative degradation at low temperatures. Two different approaches were used to attempt to measure the transmission of energy through MLI at low temperatures. A laser based measurement system was set up to directly measure transmittance and a calorimetric based measurement system was used to measure relative emittance of a single layer between aluminum foil and double aluminized Mylar. Minimal transmission at long wavelengths were observed through standard MLI blanket materials at deposition thicknesses of even 35 nm. Where transmission was measured, it was too low to effect the performance of a multilayers system. Similarly, the calorimeter showed similar increases of emissivity for both standard blanket materials and aluminum foils. Multiple different methodologies of measurement have all yielded the same result: that there is no transmission through standard MLI blanket materials at wavelengths associated with temperatures as low as 2 K.
Kim, Yun Ho; Kim, Jungho; Lee, Jong-Man; Park, Hyeonseo
2016-03-01
A beta-gamma coincidence system has been developed for measuring (198)Au activity in gold foils. The system was validated by Monte Carlo simulations and by measuring the activity of a (60)Co point-source. To study effects such as self-shielding of beta particles in gold foils, (198)Au activity measurements and simulations were performed for various scintillators and foil sizes. The measured (198)Au activities were ~1% above the reference activity, which might be due to self-shielding of beta particles. The measured and simulated (198)Au activities agreed, suggesting feasibility of precise activity measurement. Copyright © 2015 Elsevier Ltd. All rights reserved.
Hall Thruster Plume Measurements On-Board the Russian Express Satellites
NASA Technical Reports Server (NTRS)
Manzella, David; Jankovsky, Robert; Elliott, Frederick; Mikellides, Ioannis; Jongeward, Gary; Allen, Doug
2001-01-01
The operation of North-South and East-West station-keeping Hall thruster propulsion systems on-board two Russian Express-A geosynchronous communication satellites were investigated through a collaborative effort with the manufacturer of the spacecraft. Over 435 firings of 16 different thrusters with a cumulative run time of over 550 hr were reported with no thruster failures. Momentum transfer due to plume impingement was evaluated based on reductions in the effective thrust of the SPT-100 thrusters and induced disturbance torques determined based on attitude control system data and range data. Hall thruster plasma plume effects on the transmission of C-band and Ku-band communication signals were shown to be negligible. On-orbit ion current density measurements were made and subsequently compared to predictions and ground test data. Ion energy, total pressure, and electric field strength measurements were also measured on-orbit. The effect of Hall thruster operation on solar array performance over several months was investigated. A subset of these data is presented.
Automated system for measuring temperature profiles inside ITS-90 fixed-point cells
NASA Astrophysics Data System (ADS)
Hiti, Miha; Bojkovski, Jovan; Batagelj, Valentin; Drnovsek, Janko
2005-11-01
The defining fixed points of the International Temperature Scale of 1990 (ITS-90) are temperature reference points for temperature calibration. The measured temperature inside the fixed-point cell depends on thermometer immersion, since measurements are made below the surface of the fixed-point material and the additional effect of the hydrostatic pressure has to be taken into account. Also, the heat flux along the thermometer stem can affect the measured temperature. The paper presents a system that enables accurate and reproducible immersion profile measurements for evaluation of measurement sensitivity and adequacy of thermometer immersion. It makes immersion profile measurements possible, where a great number of repetitions and long measurement periods are required, and reduces the workload on the user for performing such measurements. The system is flexible and portable and was developed for application to existing equipment in the laboratory. Results of immersion profile measurements in a triple point of water fixed-point cell are presented.
Probing the holographic principle using dynamical gauge effects from open spin-orbit coupling
NASA Astrophysics Data System (ADS)
Zhao, Jianshi; Price, Craig; Liu, Qi; Gemelke, Nathan
2016-05-01
Dynamical gauge fields result from locally defined symmetries and an effective over-labeling of quantum states. Coupling atoms weakly to a reservoir of laser modes can create an effective dynamical gauge field purely due to the disregard of information in the optical states. Here we report measurements revealing effects of open spin-orbit coupling in a system where an effective model can be formed from a non-abelian SU(2) × U(1) field theory following the Yang-Mills construct. Forming a close analogy to dynamical gauge effects in quantum chromodynamics, we extract a measure of atomic motion which reveals the analog of a closing mass gap for the relevant gauge boson, shedding insight on long standing open problems in gauge-fixing scale anomalies. Using arguments following the holographic principle, we measure scaling relations which can be understood by quantifying information present in the local potential. New prospects using these techniques for developing fractionalization of multi-particle and macroscopic systems using dissipative and non-abelian gauge fields will also be discussed. We acknowledge support from NSF Award No. 1068570, and the Charles E. Kaufman Foundation.
Nonlinearity measure and internal model control based linearization in anti-windup design
DOE Office of Scientific and Technical Information (OSTI.GOV)
Perev, Kamen
2013-12-18
This paper considers the problem of internal model control based linearization in anti-windup design. The nonlinearity measure concept is used for quantifying the control system degree of nonlinearity. The linearizing effect of a modified internal model control structure is presented by comparing the nonlinearity measures of the open-loop and closed-loop systems. It is shown that the linearization properties are improved by increasing the control system local feedback gain. However, it is emphasized that at the same time the stability of the system deteriorates. The conflicting goals of stability and linearization are resolved by solving the design problem in different frequencymore » ranges.« less
Güler, I; Burunkaya, M
2002-01-01
Relative humidity levels of an incubator were measured and controlled. An ultrasonic nebulizer system as an active humidifier was used to humidify the incubator environment. An integrated circuit-type humidity sensor was used to measure the humidity level of the incubator environment. Measurement and control processes were achieved by a PIC microcontroller. The high-performance and high-speed PIC provided the flexibility of the system. The developed system can be used effectively for the intensive care of newborns and/or premature babies. Since the humidifier generates an aerosol in ambient conditions, it is possible to provide the high relative humidity level for therapeutic and diagnostic purposes in medicine.
NASA Technical Reports Server (NTRS)
Wong, R. C.; Owen, H. A., Jr.; Wilson, T. G.; Rodriguez, G. E.
1980-01-01
Small-signal modeling techniques are used in a system stability analysis of a breadboard version of a complete functional electrical power system. The system consists of a regulated switching dc-to-dc converter, a solar-cell-array simulator, a solar-array EMI filter, battery chargers and linear shunt regulators. Loss mechanisms in the converter power stage, including switching-time effects in the semiconductor elements, are incorporated into the modeling procedure to provide an accurate representation of the system without requiring frequency-domain measurements to determine the damping factor. The small-signal system model is validated by the use of special measurement techniques which are adapted to the poor signal-to-noise ratio encountered in switching-mode systems. The complete electrical power system with the solar-array EMI filter is shown to be stable over the intended range of operation.
Traceable calibration of ultraviolet meters used with broadband, extended sources.
Coleman, A J; Collins, M; Saunders, J E
2000-01-01
A calibration system has been developed to provide increased accuracy in the measurement of the irradiance responsivity appropriate for UV meters used with broadband, extended sources of the type employed in phototherapy. The single wavelength responsivity of the test meter is obtained in the wavelength range 250-400 nm by intercomparison with a transfer standard meter in a narrow, monochromatic beam. Traceability to primary standard irradiance scales is provided via the National Measurement System with a best uncertainty of 7% (at 95% confidence). The effective responsivity of the test meter, when used with broadband extended sources, is calculated using the measured spectral and angular response of the meter and tabulated data on the spectral and spatial characteristics of the source radiance. The uncertainty in the effective responsivity, independent of the source variability, is estimated to be 10% (at 95% confidence). The advantages of this calibration system over existing approaches are discussed.
Study of glass hydrometer calibration by hydrostatic weighting
NASA Astrophysics Data System (ADS)
Chen, Chaoyun; Wang, Jintao; Li, Zhihao; Zhang, Peiman
2016-01-01
Glass hydrometers are simple but effective instruments for measuring the density of liquids. Glass hydrometers calibration based on the Archimedes law, using silicon ring as a reference standard solid density, n-tridecane with density stability and low surface tension as the standard working liquid, based on hydrostatic weighing method designs a glass hydrometer calibration system. Glass hydrometer calibration system uses CCD image measurement system to align the scale of hydrometer and liquid surface, with positioning accuracy of 0.01 mm. Surface tension of the working liquid is measured by Whihemy plate. According to twice glass hydrometer weighing in the air and liquid can calculate the correction value of the current scale. In order to verify the validity of the principle of the hydrostatic weighing method of glass hydrometer calibration system, for measuring the density range of (770-790) kg/m3, with a resolution of 0.2 kg/m3 of hydrometer. The results of measurement compare with the Physikalisch-Technische Bundesanstalt(PTB) ,verifying the validity of the calibration system.
NASA Astrophysics Data System (ADS)
Welch, Kyle; Liebman-Pelaez, Alexander; Corwin, Eric
Equilibrium statistical mechanics is traditionally limited to thermal systems. Can it be applied to athermal, non-equilibrium systems that nonetheless satisfy the basic criteria of steady-state chaos and isotropy? We answer this question using a macroscopic system of chaotic surface waves which is, by all measures, non-equilibrium. The waves are generated in a dish of water that is vertically oscillated above a critical amplitude. We have constructed a rheometer that actively measures the drag imparted by the waves on a buoyant particle, a quantity entirely divorced in origin from the drag imparted by the fluid in which the particle floats. We also perform a separate, passive measurement, extracting a diffusion constant and effective temperature. Having directly measured all three properties (temperature, diffusion constant, and drag coefficient) we go on to show that our macroscopic, non-equilibrium case is wholly consistent with the Einstein relation, a classic result for equilibrium thermal systems.
Li, Meina; Kim, Youn Tae
2017-01-01
Athlete evaluation systems can effectively monitor daily training and boost performance to reduce injuries. Conventional heart-rate measurement systems can be easily affected by artifact movement, especially in the case of athletes. Significant noise can be generated owing to high-intensity activities. To improve the comfort for athletes and the accuracy of monitoring, we have proposed to combine robust heart rate and agility index monitoring algorithms into a small, light, and single node. A band-pass-filter-based R-wave detection algorithm was developed. The agility index was calculated by preprocessing with band-pass filtering and employing the zero-crossing detection method. The evaluation was conducted under both laboratory and field environments to verify the accuracy and reliability of the algorithm. The heart rate and agility index measurements can be wirelessly transmitted to a personal computer in real time by the ZigBee telecommunication system. The results show that the error rate of measurement of the heart rate is within 2%, which is comparable with that of the traditional wired measurement method. The sensitivity of the agility index, which could be distinguished as the activity speed, changed slightly. Thus, we confirmed that the developed algorithm could be used in an effective and safe exercise-evaluation system for athletes. PMID:29039763
A Self-Calibrating Radar Sensor System for Measuring Vital Signs.
Huang, Ming-Chun; Liu, Jason J; Xu, Wenyao; Gu, Changzhan; Li, Changzhi; Sarrafzadeh, Majid
2016-04-01
Vital signs (i.e., heartbeat and respiration) are crucial physiological signals that are useful in numerous medical applications. The process of measuring these signals should be simple, reliable, and comfortable for patients. In this paper, a noncontact self-calibrating vital signs monitoring system based on the Doppler radar is presented. The system hardware and software were designed with a four-tiered layer structure. To enable accurate vital signs measurement, baseband signals in the radar sensor were modeled and a framework for signal demodulation was proposed. Specifically, a signal model identification method was formulated into a quadratically constrained l1 minimization problem and solved using the upper bound and linear matrix inequality (LMI) relaxations. The performance of the proposed system was comprehensively evaluated using three experimental sets, and the results indicated that this system can be used to effectively measure human vital signs.
NASA Astrophysics Data System (ADS)
Dong, Shuai; Yu, Shanshan; Huang, Zheng; Song, Shoutan; Shao, Xinxing; Kang, Xin; He, Xiaoyuan
2017-12-01
Multiple digital image correlation (DIC) systems can enlarge the measurement field without losing effective resolution in the area of interest (AOI). However, the results calculated in substereo DIC systems are located in its local coordinate system in most cases. To stitch the data obtained by each individual system, a data merging algorithm is presented in this paper for global measurement of multiple stereo DIC systems. A set of encoded targets is employed to assist the extrinsic calibration, of which the three-dimensional (3-D) coordinates are reconstructed via digital close range photogrammetry. Combining the 3-D targets with precalibrated intrinsic parameters of all cameras, the extrinsic calibration is significantly simplified. After calculating in substereo DIC systems, all data can be merged into a universal coordinate system based on the extrinsic calibration. Four stereo DIC systems are applied to a four point bending experiment of a steel reinforced concrete beam structure. Results demonstrate high accuracy for the displacement data merging in the overlapping field of views (FOVs) and show feasibility for the distributed FOVs measurement.
Reducing Risk of Noise-Induced Hearing Loss in Collegiate Music Ensembles Using Ambient Technology.
Powell, Jason; Chesky, Kris
2017-09-01
Student musicians are at risk for noise-induced hearing loss (NIHL) as they develop skills and perform during instructional activities. Studies using longitudinal dosimeter data show that pedagogical procedures and instructor behaviors are highly predictive of NIHL risk, thus implying the need for innovative approaches to increase instructor competency in managing instructional activities without interfering with artistic and academic freedom. Ambient information systems, an emerging trend in human-computer interaction that infuses psychological behavioral theories into technologies, can help construct informative risk-regulating systems. The purpose of this study was to determine the effects of introducing an ambient information system into the ensemble setting. The system used two ambient displays and a counterbalanced within-subjects treatment study design with six jazz ensemble instructors to determine if the system could induce a behavior change that alters trends in measures resulting from dosimeter data. This study assessed efficacy using time series analysis to determine changes in eight statistical measures of behavior over a 9-wk period. Analysis showed that the system was effective, as all instructors showed changes in a combination of measures. This study is in an important step in developing non-interfering technology to reduce NIHL among academic musicians.
Cervero-Liceras, Francisco; McKee, Martin; Legido-Quigley, Helena
2015-01-01
The recent financial crisis has seen severe austerity measures imposed on the Spanish health care system. However, the impacts are not yet well documented. We describe the findings from a qualitative study that explored health care professionals' perception of the effects of austerity measures in the Spanish Autonomous Community of Valencia. A total of 21 semi-structured interviews were conducted with health professionals, recorded and fully transcribed. We coded all interviews using an inductive approach, drawing on techniques used in the constant comparative method. Health professionals reported increases in mental health conditions and malnutrition linked to a loss of income from employment and cuts to social support services. Health care professionals perceived that the quality of health care had become worse and health outcomes had deteriorated as a result of austerity measures. Interviewees also suggested that increased copayments meant that a growing number of patients could not afford necessary medication. While a few supported reforms and policies, such as the increase in copayments for pharmaceuticals, most opposed the privatization of health care facilities, and the newly introduced Royal Decree-law 16/2012, particularly the exclusion of non-residents from the health care system. The prevailing perception is that austerity measures are having negative effects on the quality of the health care system and population health. In light of this evidence there is an urgent need to evaluate the austerity measures recently introduced and to consider alternatives such as the derogation of the Royal Decree-law 16/2012. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Leggiero, Michael; Bulusu, Kartik V.; Plesniak, Michael W.
2013-11-01
The main objective of this study was to examine inertial effects in a 180-degree model of curved arteries under pulsatile inflow conditions. Two-component, two-dimensional particle image velocimetery (2C-2D PIV) data were acquired upstream of and at several cross-sectional locations in the curved artery model. A blood-analog fluid comprised of 71% saturated sodium iodide solution, 28% glycerol and 1% distilled water (by volume) was subjected to multi-harmonic pulsatile inflow functions. First, signal time-lag was quantified by cross-correlating the input (voltage-time) supplied to a programmable pump and the output PIV (flow rate-time) measurements. The experiment was then treated as a linear, time-invariant system, and frequency response was estimated for phase shifts across a certain spectrum. Input-output signal dissimilarities were attributable to intrinsic inertial effects of flow. By coupling pressure-time and upstream flow rate-time measurements, the experiment was modeled using system identification methods. Results elucidate the role of inertial effects in fluid flow velocity measurements and the effect of these delays on secondary flow structure detection in a curved artery model. Supported by the NSF Grant No. CBET- 0828903 and GW Center for Biomimetics and Bioinspired Engineering.
Ostaszewski, Michal; Pauk, Jolanta
2018-05-16
Gait analysis is a useful tool medical staff use to support clinical decision making. There is still an urgent need to develop low-cost and unobtrusive mobile health monitoring systems. The goal of this study was twofold. Firstly, a wearable sensor system composed of plantar pressure insoles and wearable sensors for joint angle measurement was developed. Secondly, the accuracy of the system in the measurement of ground reaction forces and joint moments was examined. The measurements included joint angles and plantar pressure distribution. To validate the wearable sensor system and examine the effectiveness of the proposed method for gait analysis, an experimental study on ten volunteer subjects was conducted. The accuracy of measurement of ground reaction forces and joint moments was validated against the results obtained from a reference motion capture system. Ground reaction forces and joint moments measured by the wearable sensor system showed a root mean square error of 1% for min. GRF and 27.3% for knee extension moment. The correlation coefficient was over 0.9, in comparison with the stationary motion capture system. The study suggests that the wearable sensor system could be recommended both for research and clinical applications outside a typical gait laboratory.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paduano, L.; Sartorio, R.; Vitagliano, V.
Diffusion coefficients in the ternary system {alpha}-cyclodextrin (at one concentration)-L-phenylalanine (at four concentrations)-water have been measured by using the Gouy interferometric technique. The effect of the inclusion equilibrium on the cross-term diffusion coefficients was observed. The measured diffusion coefficients in the ternary systems were used to calculate values of the binding constants. These values are in good agreement with the value obtained from calorimetric studies.
ERIC Educational Resources Information Center
Martínez, José Felipe; Schweig, Jonathan; Goldschmidt, Pete
2016-01-01
A key question facing teacher evaluation systems is how to combine multiple measures of complex constructs into composite indicators of performance. We use data from the Measures of Effective Teaching (MET) study to investigate the measurement properties of composite indicators obtained under various conjunctive, disjunctive (or complementary),…
Álvarez, Fernando; Garnacho, Fernando; Ortego, Javier; Sánchez-Urán, Miguel Ángel
2015-01-01
Partial discharge (PD) measurements provide valuable information for assessing the condition of high voltage (HV) insulation systems, contributing to their quality assurance. Different PD measuring techniques have been developed in the last years specially designed to perform on-line measurements. Non-conventional PD methods operating in high frequency bands are usually used when this type of tests are carried out. In PD measurements the signal acquisition, the subsequent signal processing and the capability to obtain an accurate diagnosis are conditioned by the selection of a suitable detection technique and by the implementation of effective signal processing tools. This paper proposes an optimized electromagnetic detection method based on the combined use of wideband PD sensors for measurements performed in the HF and UHF frequency ranges, together with the implementation of powerful processing tools. The effectiveness of the measuring techniques proposed is demonstrated through an example, where several PD sources are measured simultaneously in a HV installation consisting of a cable system connected by a plug-in terminal to a gas insulated substation (GIS) compartment. PMID:25815452
Social instability and immunity in rhesus monkeys: the role of the sympathetic nervous system.
Capitanio, John P; Cole, Steven W
2015-05-26
Social instability can adversely affect endocrine, immune and health outcomes, and recent evidence suggests that the sympathetic nervous system (SNS) might mediate these effects. We conducted two studies with adult male rhesus monkeys (Macaca mulatta) to understand how social conditions affect measures of SNS activity and immune function. In Experiment 1, animals were socialized in stable social conditions, then were switched to unstable (stressful) social conditions, then were returned to stable conditions. Analysis revealed quadratic effects for measures of behaviour, urinary metabolites of epinephrine and norepinephrine, and expression of immune response genes: as expected, social instability adversely impacted most measures, and the effects remediated upon re-imposition of stable conditions. Cortisol levels were unaffected. In Experiment 2, we used the sympathomimetic drug methamphetamine to challenge the SNS; animals also underwent socialization in stable or unstable groups. Surprisingly, while methamphetamine elevated plasma catecholamines, responses in lymph nodes tracked the social, and not the drug, condition: social instability upregulated the density of SNS fibres in lymph nodes and downregulated Type I interferon gene expression. Together, these results indicate that the SNS is extremely sensitive to social conditions; full understanding of the adverse effects of social instability on health should therefore incorporate measures of this health-relevant system. © 2015 The Author(s) Published by the Royal Society. All rights reserved.
Method for the evaluation 3D noncontact inspection systems
NASA Astrophysics Data System (ADS)
Harding, Kevin
2011-08-01
Three dimensional, optical measurement systems are becoming more widely used in applications ranging from aerospace to automotive. These systems offer the potential for high speed, good accuracy, and more complete information than older contact based technology. However, the primary standards employed by many to evaluate these systems were specifically designed around touch probe based coordinate measurement machines (CMMs). These standards were designed to work with the limitations of touch probes, and in many cases cannot measure the types of features and errors associated with non-contact systems. This paper will discuss the deficiencies of employing contact based characterization tests to non-contact systems, and suggest a new set of tests specifically to cover the many aspects pertinent to non-contact, optical 3D measurement systems. Some of the performance aspects addressed in this characterization method include: sensitivity to surface reflectivity and roughness, the effect of angle of incidence of measurements, means to characterize volumetric variations that may fit complex functions, and considerations of both spatial and depth resolutions. Specific application areas will be discussed as well as the use of artifacts to provide practical functional data that can predict system performance on real world parts.
Torsional vibration measurements on rotating shaft system using laser doppler vibrometer
NASA Astrophysics Data System (ADS)
Xiang, Ling; Yang, Shixi; Gan, Chunbiao
2012-11-01
In this work, a laser torsional vibrameter was used to measure the torsion vibration of a rotating shaft system under electrical network impact. Based on the principles of laser Doppler velocimetry, the laser torsional vibrometer (LTV) are non-contact measurement of torsional oscillation of rotating shafts, offering significant advantages over conventional techniques. Furthermore, a highly complex shafting system is analyzed by a modified Riccati torsional transfer matrix. The system is modeled as a chain consisting of an elastic spring with concentrated mass points, and the multi-segments lumped mass model is established for this shafting system. By the modified Riccati torsional transfer matrix method, an accumulated calculation is effectively eliminated to obtain the natural frequencies. The electrical network impacts can activize the torsional vibration of shaft system, and the activized torsion vibration frequencies contained the natural frequencies of shaft system. The torsional vibrations of the shaft system were measured under electrical network impacts in laser Doppler torsional vibrometer. By comparisons, the natural frequencies by measurement were consistent with the values by calculation. The results verify the instrument is robust, user friendly and can be calibrated in situ. The laser torsional vibrometer represents a significant step forward in rotating machinery diagnostics.
Pilot-Assisted Inertial Navigation System Aiding Using Bearings-Only Measurements Taken Over Time
2015-03-26
δψ̇ ≈ −ω(n)in ×ψ + δω (n) in −Cnb δω (b) ib (11) Velocity error equation dynamics are expressed as Equation (12). Where the Coriolis effect comes into...navigation were effectively neglected due to the accuracy and technology development associated with GPS integration. The dependence on GPS was driven by the...bearing measurements used are more effective with high Signal-to-Noise Ratio (SNR) Line of Sight (LOS) measurements in a low Geometric Dilution of
ERIC Educational Resources Information Center
Calfee, Robert C.; Calfee, Kathryn Hoover
The Beginning Teacher Evaluation Study, Phase II, was a research project on effective teaching behavior--what teachers do that significantly affects what and how pupils learn. The purposes of Phase II were to (1) develop an assessment system for measuring teacher and student behaviors and other factors which could influence each of them and their…
Beta-Blockers: An Abstracted Bibliography.
1989-04-04
on subjects in the supine position. Blood flow was measured by venous occlusion plethys- mography. Prugs were administered via indwelling catheter (one...PROCEDURES: Noninvasive measuremert of maximum oxygen intake, invasive measurement of systemic and pulmonary arterial pressures, arterial and mixed venous ...ratio was approximately 0.1:1. Central nervous system-related effects associated with propranolol and metoprolol appear to be the result of high brain
Measuring School and Teacher Value Added for IMPACT and TEAM in DC Public Schools. Final Report
ERIC Educational Resources Information Center
Isenberg, Eric; Hock, Heinrich
2010-01-01
The District of Columbia Public Schools (DCPS) has incorporated measures of school and teacher effectiveness, based on student test score growth, into a new teacher assessment system known as IMPACT. Implemented for the first time during the 2009-2010 school year, IMPACT is an assessment system with significant consequences. Prior to the start of…
2001-02-01
ECM Electronic Countermeasures EEG Electroencephalograph EKG Electrocardiogram EPA Extended Planning Annex EPF Equipment Performance Factor...related physiological measures Changes in the brain/neural system caused by workload. Rehmann, 1995, p. 12 M 8.2.16 Electroencephalograph ( EEG ...architecture TMD Operational Objectives: Destroy Theater Missiles ( TM ) and their infrastructure as far forward as possible (Attack Operations
State dragging using the quantum Zeno effect
NASA Astrophysics Data System (ADS)
Hacohen-Gourgy, Shay; Martin, Leigh; GarcíA-Pintos, Luis Pedro; Dressel, Justin; Siddiqi, Irfan
The quantum Zeno effect is the suppression of Hamiltonian evolution by continuous measurement. It arises as a consequence of the quantum back-action pushing the state towards an eigenstate of the measurement operator. Rotating the operator at a rate much slower than the measurement rate will effectively drag the state with it. We use our recently developed scheme, which enables dynamic control of the measurement operator, to demonstrate this dragging effect on a superconducting transmon qubit. Since the system is continuously measured, the deterministic trajectory can be monitored, and quantum jumps can be detected in real-time. Furthermore, we perform this with two observables that are set to be either commuting or non-commuting, demonstrating new quantum dynamics. This work was supported by the Army Research Office and the Air Force Research Laboratory.
Lee, Sang Cheol; Hong, Sung Kyung
2016-12-11
This paper presents an algorithm for velocity-aided attitude estimation for helicopter aircraft using a microelectromechanical system inertial-measurement unit. In general, high- performance gyroscopes are used for estimating the attitude of a helicopter, but this type of sensor is very expensive. When designing a cost-effective attitude system, attitude can be estimated by fusing a low cost accelerometer and a gyro, but the disadvantage of this method is its relatively low accuracy. The accelerometer output includes a component that occurs primarily as the aircraft turns, as well as the gravitational acceleration. When estimating attitude, the accelerometer measurement terms other than gravitational ones can be considered as disturbances. Therefore, errors increase in accordance with the flight dynamics. The proposed algorithm is designed for using velocity as an aid for high accuracy at low cost. It effectively eliminates the disturbances of accelerometer measurements using the airspeed. The algorithm was verified using helicopter experimental data. The algorithm performance was confirmed through a comparison with an attitude estimate obtained from an attitude heading reference system based on a high accuracy optic gyro, which was employed as core attitude equipment in the helicopter.
Lee, Sang Cheol; Hong, Sung Kyung
2016-01-01
This paper presents an algorithm for velocity-aided attitude estimation for helicopter aircraft using a microelectromechanical system inertial-measurement unit. In general, high- performance gyroscopes are used for estimating the attitude of a helicopter, but this type of sensor is very expensive. When designing a cost-effective attitude system, attitude can be estimated by fusing a low cost accelerometer and a gyro, but the disadvantage of this method is its relatively low accuracy. The accelerometer output includes a component that occurs primarily as the aircraft turns, as well as the gravitational acceleration. When estimating attitude, the accelerometer measurement terms other than gravitational ones can be considered as disturbances. Therefore, errors increase in accordance with the flight dynamics. The proposed algorithm is designed for using velocity as an aid for high accuracy at low cost. It effectively eliminates the disturbances of accelerometer measurements using the airspeed. The algorithm was verified using helicopter experimental data. The algorithm performance was confirmed through a comparison with an attitude estimate obtained from an attitude heading reference system based on a high accuracy optic gyro, which was employed as core attitude equipment in the helicopter. PMID:27973429
Adams, Vanessa M; Setterfield, Samantha A; Douglas, Michael M; Kennard, Mark J; Ferdinands, Keith
2015-11-05
Protected areas remain a cornerstone for global conservation. However, their effectiveness at halting biodiversity decline is not fully understood. Studies of protected area benefits have largely focused on measuring their impact on halting deforestation and have neglected to measure the impacts of protected areas on other threats. Evaluations that measure the impact of protected area management require more complex evaluation designs and datasets. This is the case across realms (terrestrial, freshwater, marine), but measuring the impact of protected area management in freshwater systems may be even more difficult owing to the high level of connectivity and potential for threat propagation within systems (e.g. downstream flow of pollution). We review the potential barriers to conducting impact evaluation for protected area management in freshwater systems. We contrast the barriers identified for freshwater systems to terrestrial systems and discuss potential measurable outcomes and confounders associated with protected area management across the two realms. We identify key research gaps in conducting impact evaluation in freshwater systems that relate to three of their major characteristics: variability, connectivity and time lags in outcomes. Lastly, we use Kakadu National Park world heritage area, the largest national park in Australia, as a case study to illustrate the challenges of measuring impacts of protected area management programmes for environmental outcomes in freshwater systems. © 2015 The Author(s).
Adams, Vanessa M.; Setterfield, Samantha A.; Douglas, Michael M.; Kennard, Mark J.; Ferdinands, Keith
2015-01-01
Protected areas remain a cornerstone for global conservation. However, their effectiveness at halting biodiversity decline is not fully understood. Studies of protected area benefits have largely focused on measuring their impact on halting deforestation and have neglected to measure the impacts of protected areas on other threats. Evaluations that measure the impact of protected area management require more complex evaluation designs and datasets. This is the case across realms (terrestrial, freshwater, marine), but measuring the impact of protected area management in freshwater systems may be even more difficult owing to the high level of connectivity and potential for threat propagation within systems (e.g. downstream flow of pollution). We review the potential barriers to conducting impact evaluation for protected area management in freshwater systems. We contrast the barriers identified for freshwater systems to terrestrial systems and discuss potential measurable outcomes and confounders associated with protected area management across the two realms. We identify key research gaps in conducting impact evaluation in freshwater systems that relate to three of their major characteristics: variability, connectivity and time lags in outcomes. Lastly, we use Kakadu National Park world heritage area, the largest national park in Australia, as a case study to illustrate the challenges of measuring impacts of protected area management programmes for environmental outcomes in freshwater systems. PMID:26460127
Method and system for measurement of mechanical properties of molecules and cells
NASA Technical Reports Server (NTRS)
Fredberg, Jeffrey J. (Inventor); Butler, James P. (Inventor); Ingber, Donald E. (Inventor); Wang, Ning (Inventor)
1996-01-01
Mechanical stresses and deformations are applied directly to cell surface receptors or molecules and measured using a system including a magnetic twisting device in combination with ferromagnetic microbeads coated with ligands for integrins or any other surface receptors. The system can be used diagnostically to characterize cells and molecules and to determine the effect of transformation and compounds, including drugs, on the cells and molecules. The system can also be used to induce cells to grow or alter production of molecules by the cells.
Roggemann, M C; Welsh, B M; Montera, D; Rhoadarmer, T A
1995-07-10
Simulating the effects of atmospheric turbulence on optical imaging systems is an important aspect of understanding the performance of these systems. Simulations are particularly important for understanding the statistics of some adaptive-optics system performance measures, such as the mean and variance of the compensated optical transfer function, and for understanding the statistics of estimators used to reconstruct intensity distributions from turbulence-corrupted image measurements. Current methods of simulating the performance of these systems typically make use of random phase screens placed in the system pupil. Methods exist for making random draws of phase screens that have the correct spatial statistics. However, simulating temporal effects and anisoplanatism requires one or more phase screens at different distances from the aperture, possibly moving with different velocities. We describe and demonstrate a method for creating random draws of phase screens with the correct space-time statistics for a bitrary turbulence and wind-velocity profiles, which can be placed in the telescope pupil in simulations. Results are provided for both the von Kármán and the Kolmogorov turbulence spectra. We also show how to simulate anisoplanatic effects with this technique.
NASA Technical Reports Server (NTRS)
Anderson, Karl F. (Inventor)
1994-01-01
A constant current loop measuring system is provided for measuring a characteristic of an environment. The system comprises a first impedance positionable in the environment, a second impedance coupled in series with said first impedance and a parasitic impedance electrically coupled to the first and second impedances. A current generating device, electrically coupled in series with the first and second impedances, provides a constant current through the first and second impedances to produce first and second voltages across the first and second impedances, respectively, and a parasitic voltage across the parasitic impedance. A high impedance voltage measuring device measures a voltage difference between the first and second voltages independent of the parasitic voltage to produce a characteristic voltage representative of the characteristic of the environment.
NASA Astrophysics Data System (ADS)
Shi, Guang; Wang, Wen; Zhang, Fumin
2018-03-01
The measurement precision of frequency-modulated continuous-wave (FMCW) laser distance measurement should be proportional to the scanning range of the tunable laser. However, the commercial external cavity diode laser (ECDL) is not an ideal tunable laser source in practical applications. Due to the unavoidable mode hopping and scanning nonlinearity of the ECDL, the measurement precision of FMCW laser distance measurements can be substantially affected. Therefore, an FMCW laser ranging system with two auxiliary interferometers is proposed in this paper. Moreover, to eliminate the effects of ECDL, the frequency-sampling method and mode hopping influence suppression method are employed. Compared with a fringe counting interferometer, this FMCW laser ranging system has a measuring error of ± 20 μm at the distance of 5.8 m.
New paradigms for measuring clinical performance using electronic health records.
Weiner, Jonathan P; Fowles, Jinnet B; Chan, Kitty S
2012-06-01
Measures of provider success are the centerpiece of quality improvement and pay-for-performance programs around the globe. In most nations, these measures are derived from administrative records, paper charts and consumer surveys; increasingly, electronic patient record systems are also being used. We use the term 'e-QMs' to describe quality measures that are based on data found within electronic health records and other related health information technology (HIT). We offer a framework or typology for e-QMs and describe opportunities and impediments associated with the transition from old to new If public and private systems of care are to effectively use HIT to support and evaluate health-care system quality and safety, the quality measurement field must embrace new paradigms and strategically address a series of technical, conceptual and practical challenges.
NASA Astrophysics Data System (ADS)
Tapilouw, Abraham Mario; Chen, Liang-Chia; Xuan-Loc, Nguyen; Chen, Jin-Liang
2014-08-01
A Micro-electro-mechanical-system (MEMS) is a widely used component in many industries, including energy, biotechnology, medical, communications, and automotive industries. However, effective inspection systems are also needed to ensure the functional reliability of MEMS. This study developed a stroboscopic coherence scanning Interferometry (SCSI) technique for measuring key characteristics typically used as criteria in MEMS inspections. Surface profiles of MEMS both static and dynamic conditions were measured by means of coherence scanning Interferometry (CSI). Resonant frequencies of vibrating MEMS were measured by deformation of interferogram fringes for out-of-plane vibration and by image correlation for in-plane vibration. The measurement bandwidth of the developed system can be tuned up to three megahertz or higher for both in-plane and out-of-plane measurement of MEMS.
Brake testing methodology study : driver effects testing
DOT National Transportation Integrated Search
1999-03-01
The National Highway Traffic Safety Administration (NHTSA) is exploring the feasibility of developing brake tests to measure brake system performance of light vehicles. Developing test procedures requires controlling test variability so that measured...
Spindle, Tory R.; Breland, Alison B.; Karaoghlanian, Nareg V.; Shihadeh, Alan L.
2015-01-01
Introduction: Electronic cigarettes (ECIGs) heat a nicotine-containing solution; the resulting aerosol is inhaled by the user. Nicotine delivery may be affected by users’ puffing behavior (puff topography), and little is known about the puff topography of ECIG users. Puff topography can be measured using mouthpiece-based computerized systems. However, the extent to which a mouthpiece influences nicotine delivery and subjective effects in ECIG users is unknown. Methods: Plasma nicotine concentration, heart rate, and subjective effects were measured in 13 experienced ECIG users who used their preferred ECIG and liquid (≥12mg/ml nicotine) during 2 sessions (with or without a mouthpiece). In both sessions, participants completed an ECIG use session in which they were instructed to take 10 puffs with 30-second inter-puff intervals. Puff topography was recorded in the mouthpiece condition. Results: Almost all measures of the effects of ECIG use were independent of topography measurement. Collapsed across session, mean plasma nicotine concentration increased by 16.8ng/ml, and mean heart rate increased by 8.5 bpm (ps < .05). Withdrawal symptoms decreased significantly after ECIG use. Participants reported that the mouthpiece affected awareness and made ECIG use more difficult. Relative to previously reported data for tobacco cigarette smokers using similar topography measurement equipment, ECIG-using participants took larger and longer puffs with lower flow rates. Conclusions: In experienced ECIG users, measuring ECIG topography did not influence ECIG-associated nicotine delivery or most measures of withdrawal suppression. Topography measurement systems will need to account for the low flow rates observed for ECIG users. PMID:25239957
Spindle, Tory R; Breland, Alison B; Karaoghlanian, Nareg V; Shihadeh, Alan L; Eissenberg, Thomas
2015-02-01
Electronic cigarettes (ECIGs) heat a nicotine-containing solution; the resulting aerosol is inhaled by the user. Nicotine delivery may be affected by users' puffing behavior (puff topography), and little is known about the puff topography of ECIG users. Puff topography can be measured using mouthpiece-based computerized systems. However, the extent to which a mouthpiece influences nicotine delivery and subjective effects in ECIG users is unknown. Plasma nicotine concentration, heart rate, and subjective effects were measured in 13 experienced ECIG users who used their preferred ECIG and liquid (≥ 12 mg/ml nicotine) during 2 sessions (with or without a mouthpiece). In both sessions, participants completed an ECIG use session in which they were instructed to take 10 puffs with 30-second inter-puff intervals. Puff topography was recorded in the mouthpiece condition. Almost all measures of the effects of ECIG use were independent of topography measurement. Collapsed across session, mean plasma nicotine concentration increased by 16.8 ng/ml, and mean heart rate increased by 8.5 bpm (ps < .05). Withdrawal symptoms decreased significantly after ECIG use. Participants reported that the mouthpiece affected awareness and made ECIG use more difficult. Relative to previously reported data for tobacco cigarette smokers using similar topography measurement equipment, ECIG-using participants took larger and longer puffs with lower flow rates. In experienced ECIG users, measuring ECIG topography did not influence ECIG-associated nicotine delivery or most measures of withdrawal suppression. Topography measurement systems will need to account for the low flow rates observed for ECIG users. © The Author 2014. Published by Oxford University Press on behalf of the Society for Research on Nicotine and Tobacco. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
An Induced Environment Contamination Monitor for the Space Shuttle
NASA Technical Reports Server (NTRS)
Miller, E. R. (Editor); Decher, R. (Editor)
1978-01-01
The Induced Environment Contamination Monitor (IECM), a set of ten instruments integrated into a self-contained unit and scheduled to fly on shuttle Orbital Flight Tests 1 through 6 and on Spacelabs 1 and 2, is described. The IECM is designed to measure the actual environment to determine whether the strict controls placed on the shuttle system have solved the contamination problem. Measurements are taken during prelaunch, ascent, on-orbit, descent, and postlanding. The on-orbit measurements are molecular return flux, background spectral intensity, molecular deposition, and optical surface effects. During the other mission phases dew point, humidity, aerosol content, and trace gas are measured as well as optical surface effects and molecular deposition. The IECM systems and thermal design are discussed. Preflight and ground operations are presented together with associated ground support equipment. Flight operations and data reduction plans are given.
Detection of Norepinephrine in Whole Blood via Fast Scan Cyclic Voltammetry.
Nicolai, Evan N; Trevathan, James K; Ross, Erika K; Lujan, J Luis; Blaha, Charles D; Bennet, Kevin E; Lee, Kendall H; Ludwig, Kip A
2017-05-01
Bioelectronic Medicines is an emerging field that capitalizes on minimally-invasive technology to stimulate the autonomic nervous system in order to evoke therapeutic biomolecular changes at the end-organ. The goal of Bioelectronic Medicines is to realize both 'precision and personalized' medicine. 'Precise' stimulation of neural circuitry creates biomolecular changes targeted exactly where needed to maximize therapeutic effects while minimizing off-target changes associated with side-effects. The therapy is then 'personalized' by utilizing implanted sensors to measure the biomolecular concentrations at, or near, the end-organ of interest and continually adjusting therapy to account for patient-specific biological changes throughout the day. To realize the promise of Bioelectronic Medicines, there is a need for minimally invasive, real-time measurement of biomarkers associated with the effects of autonomic nerve stimulation to be used for continuous titration of therapy. In this study we examine the feasibility of using fast scan cyclic voltammetry (FSCV) to measure norepinephrine levels, a neurochemical relevant to end-organ function, directly from blood. FSCV is a well-understood method for measuring electroactive neurochemicals in the central nervous system with high temporal and high spatial resolution that has yet to be adapted to the study of the autonomic nervous system. The results demonstrate that while detecting the electroactive neurochemical norepinephrine in blood is more challenging than obtaining the same FSCV measurements in a buffer solution due to biofouling of the electrode, it is feasible to utilize a minimally invasive FSCV electrode to obtain neurochemical measurements in blood.
Measuring Teacher Effectiveness with the Pennsylvania Value-Added Assessment System
ERIC Educational Resources Information Center
Bowen, Naomi
2017-01-01
The purpose of this research was to determine if the Pennsylvania Value-Added Assessment System Average Growth Index (PVAAS AGI) scores, derived from standardized tests and calculated for Pennsylvania schools, provide a valid and reliable assessment of teacher effectiveness, as these scores are currently used to derive 15% of the annual…
ERIC Educational Resources Information Center
Kinnaman, Joanna E. Strong; Farrell, Albert D.; Bisconer, Sarah W.
2006-01-01
Assessment procedures to evaluate inpatient treatment effectiveness can provide information to inform clinical practice. The Computerized Assessment System for Psychotherapy Evaluation and Research (CASPER) represents a standardized approach to assess patients' target problems that combines elements of individualized and nomothetic approaches.…
Reference-free Shack-Hartmann wavefront sensor.
Zhao, Liping; Guo, Wenjiang; Li, Xiang; Chen, I-Ming
2011-08-01
The traditional Shack-Hartmann wavefront sensing (SHWS) system measures the wavefront slope by calculating the centroid shift between the sample and a reference piece, and then the wavefront is reconstructed by a suitable iterative reconstruction method. Because of the necessity of a reference, many issues are brought up, which limit the system in most applications. This Letter proposes a reference-free wavefront sensing (RFWS) methodology, and an RFWS system is built up where wavefront slope changes are measured by introducing a lateral disturbance to the sampling aperture. By using Southwell reconstruction two times to process the measured data, the form of the wavefront at the sampling plane can be well reconstructed. A theoretical simulation platform of RFWS is established, and various surface forms are investigated. Practical measurements with two measurement systems-SHWS and our RFWS-are conducted, analyzed, and compared. All the simulation and measurement results prove and demonstrate the correctness and effectiveness of the method. © 2011 Optical Society of America
NASA Astrophysics Data System (ADS)
Vovides, Alejandra G.; Marín-Castro, Beatriz; Barradas, Guadalupe; Berger, Uta; López-Portillo, Jorge
2016-12-01
This work presents the development of a low-cost method to measure the length cable roots of black mangrove (Avicennia germinans) trees to define the boundaries of central part of the anchoring root system (CPRS) without the need to fully expose root systems. The method was tested to locate and measure the length shallow woody root systems. An ultrasonic Doppler fetal monitor (UD) and a stock of steel rods (SR) were used to probe root locations without removing sediments from the surface, measure their length and estimate root-soil plate dimensions. The method was validated by comparing measurements with root lengths taken through direct measurement of excavated cable roots and from root-soil plate radii (exposed root-soil material when a tree tips over) of five up-rooted trees with stem diameters (D130) ranging between 10 and 50 cm. The mean CPRS radius estimated with the use of the Doppler was directly correlated with tree stem diameter and was not significantly different from the root-soil plate mean radius measured from up-rooted trees or from CPRS approximated by digging trenches. Our method proved to be effective and reliable in following cable roots for large amounts of trees of both black and white mangrove trees. In a period of 40 days of work, three people were capable of measuring 648 roots belonging to 81 trees, out of which 37% were found grafted to other tree roots. This simple method can be helpful in following shallow root systems with minimal impact and help map root connection networks of grafted trees.
DOT National Transportation Integrated Search
1999-01-01
When emergency services agencies share : facilities and traffic monitoring resources : with transportation management agencies, : the efficiency and speed of incident : response are measurably improved.
Polarization effects on hard target calibration of lidar systems
NASA Technical Reports Server (NTRS)
Kavaya, Michael J.
1987-01-01
The theory of hard target calibration of lidar backscatter data, including laboratory measurements of the pertinent target reflectance parameters, is extended to include the effects of polarization of the transmitted and received laser radiation. The bidirectional reflectance-distribution function model of reflectance is expanded to a 4 x 4 matrix allowing Mueller matrix and Stokes vector calculus to be employed. Target reflectance parameters for calibration of lidar backscatter data are derived for various lidar system polarization configurations from integrating sphere and monostatic reflectometer measurements. It is found that correct modeling of polarization effects is mandatory for accurate calibration of hard target reflectance parameters and, therefore, for accurate calibration of lidar backscatter data.
NASA Astrophysics Data System (ADS)
Smith, Ross A.; Fleischman, Aaron J.; Fissell, William H.; Zorman, Christian A.; Roy, Shuvo
2011-04-01
We report an automated system for measuring the hydraulic permeability of nanoporous membranes in a tangential-flow configuration. The system was designed and built specifically for micromachined silicon nanoporous membranes (SNM) with monodisperse slit-shaped pores. These novel membranes are under development for water filtration, artificial organ and drug delivery applications. The filtration cell permits non-destructive testing of the membrane over many remove-modify-replace testing cycles, allowing for direct experiments into the effects of surface modifications on such membranes. The experimental apparatus was validated using microfluidic tubing with circular cross sections that provided similar fluidic resistances to SNM. Further validation was performed with SNM chips for which the pore dimensions were known from scanning electron microscopy measurements. The system was then used to measure the hydraulic permeability of nanoporous membranes before and after surface modification. The system yields measurements with low variance and excellent agreement with predicted values, providing a platform for determining pore sizes in micro/nanofluidic systems with tight pore size distributions to a higher degree of precision than can be achieved with traditional techniques.
USDA-ARS?s Scientific Manuscript database
Intensive aquaculture systems, particularly recirculating systems, utilize equipment such as aerators, air and water pumps, blowers, and filtration systems that inadvertently increase noise levels in fish culture tanks. Sound levels and frequencies measured within intensive aquaculture systems are w...
CASAS: An Effective Measurement System for Life Skills.
ERIC Educational Resources Information Center
Stiles, Richard L.; And Others
The California Adult Student Assessment System (CASAS) is a comprehensive educational system designed to enable adult educators to develop and evaluate a life skills curriculum for competency based educational programs. The system comprises the CASAS Competency List, the CASAS Item Bank, the User's Manual, the Curriculum Index and Matrix, and…
A new position measurement system using a motion-capture camera for wind tunnel tests.
Park, Hyo Seon; Kim, Ji Young; Kim, Jin Gi; Choi, Se Woon; Kim, Yousok
2013-09-13
Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS) could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS). The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape) of the test specimen using system identification methods (frequency domain decomposition, FDD). By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape) with the 3D measurements.
A New Position Measurement System Using a Motion-Capture Camera for Wind Tunnel Tests
Park, Hyo Seon; Kim, Ji Young; Kim, Jin Gi; Choi, Se Woon; Kim, Yousok
2013-01-01
Considering the characteristics of wind tunnel tests, a position measurement system that can minimize the effects on the flow of simulated wind must be established. In this study, a motion-capture camera was used to measure the displacement responses of structures in a wind tunnel test, and the applicability of the system was tested. A motion-capture system (MCS) could output 3D coordinates using two-dimensional image coordinates obtained from the camera. Furthermore, this remote sensing system had some flexibility regarding lab installation because of its ability to measure at relatively long distances from the target structures. In this study, we performed wind tunnel tests on a pylon specimen and compared the measured responses of the MCS with the displacements measured with a laser displacement sensor (LDS). The results of the comparison revealed that the time-history displacement measurements from the MCS slightly exceeded those of the LDS. In addition, we confirmed the measuring reliability of the MCS by identifying the dynamic properties (natural frequency, damping ratio, and mode shape) of the test specimen using system identification methods (frequency domain decomposition, FDD). By comparing the mode shape obtained using the aforementioned methods with that obtained using the LDS, we also confirmed that the MCS could construct a more accurate mode shape (bending-deflection mode shape) with the 3D measurements. PMID:24064600
ERIC Educational Resources Information Center
Regional Educational Laboratory Mid-Atlantic, 2013
2013-01-01
In this webinar, Mr. Rob Ramsdell, Vice President, Cambridge Education, discussed the use of classroom observations as one measure of teacher effectiveness in a comprehensive educator support system. Mr. Ramsdell presented research-based recommendations for improving the quality and rigor of classroom observations. This Q&A addressed the…
NASA Technical Reports Server (NTRS)
Dress, David A.
1988-01-01
Low-speed wind tunnel drag force measurements were taken on a laminar flow body of revolution free of support interference. This body was tested at zero incidence in the NASA Langley 13 inch Magnetic Suspension and Balance System (MSBS). The primary objective of these tests was to substantiate the drag force measuring capabilities of the 13 inch MSBS. A secondary objective was to obtain support interference free drag measurements on an axisymmetric body of interest. Both objectives were met. The drag force calibrations and wind-on repeatability data provide a means of assessing the drag force measuring capabilities of the 13 inch MSBS. The measured drag coefficients for this body are of interest to researchers actively involved in designing minimum drag fuselage shapes. Additional investigations included: the effects of fixing transition; the effects of fins installed in the tail; surface flow visualizations using both liquid crystals and oil flow; and base pressure measurements using a one-channel telemetry system. Two drag prediction codes were used to assess their usefulness in estimating overall body drag. These theoretical results did not compare well with the measured values because of the following: incorrect or non-existent modeling of a laminar separation bubble on the body and incorrect of non-existent estimates of base pressure drag.
Hardware Demonstration: Frequency Spectra of Transients
NASA Technical Reports Server (NTRS)
McCloskey, John; Dimov, Jen
2017-01-01
Radiated emissions measurements as specified by MIL-STD-461 are performed in the frequency domain, which is best suited to continuous wave (CW) types of signals. However, many platforms implement signals that are single event pulses or transients. Such signals can potentially generate momentary radiated emissions that can cause interference in the system, but they may be missed with traditional measurement techniques. This demonstration provides measurement and analysis techniques that effectively evaluate the potential emissions from such signals in order to evaluate their potential impacts to system performance.
Continuous quantum measurement in spin environments
NASA Astrophysics Data System (ADS)
Xie, Dong; Wang, An Min
2015-08-01
We derive a stochastic master equation (SME) which describes the decoherence dynamics of a system in spin environments conditioned on the measurement record. Markovian and non-Markovian nature of environment can be revealed by a spectroscopy method based on weak continuous quantum measurement. On account of that correlated environments can lead to a non-local open system which exhibits strong non-Markovian effects although the local dynamics are Markovian, the spectroscopy method can be used to demonstrate that there is correlation between two environments.
Impact of systemic risk in the real estate sector on banking return.
Li, Shouwei; Pan, Qing; He, Jianmin
2016-01-01
In this paper, we measure systemic risk in the real estate sector based on contingent claims analysis, and then investigate its impact on banking return. Based on the data in China, we find that systemic risk in the real estate sector has a negative effect on banking return, but this effect is temporary; banking risk aversion and implicit interest expense have considerable impact on banking return.
Quantum Zeno and anti-Zeno effects in open quantum systems
NASA Astrophysics Data System (ADS)
Zhou, Zixian; Lü, Zhiguo; Zheng, Hang; Goan, Hsi-Sheng
2017-09-01
The traditional approach to the quantum Zeno effect (QZE) and quantum anti-Zeno effect (QAZE) in open quantum systems (implicitly) assumes that the bath (environment) state returns to its original state after each instantaneous projective measurement on the system and thus ignores the cross-correlations of the bath operators between different Zeno intervals. However, this assumption is not generally true, especially for a bath with a considerably nonnegligible memory effect and for a system repeatedly projected into an initial general superposition state. We find that, in stark contrast to the result of a constant value found in the traditional approach, the scaled average decay rate in unit Zeno interval of the survival probability is generally time dependent or shows an oscillatory behavior. In the case of a strong bath correlation, the transition between the QZE and the QAZE depends sensitively on the number of measurements N . For a fixed N , a QZE region predicted by the traditional approach may in fact already be in the QAZE region. We illustrate our findings using an exactly solvable open qubit system model with a Lorentzian bath spectral density, which is directly related to realistic circuit cavity quantum electrodynamics systems. Thus the results and dynamics presented here can be verified with current superconducting circuit technology.
Bitton, Asaf; Ratcliffe, Hannah L; Veillard, Jeremy H; Kress, Daniel H; Barkley, Shannon; Kimball, Meredith; Secci, Federica; Wong, Ethan; Basu, Lopa; Taylor, Chelsea; Bayona, Jaime; Wang, Hong; Lagomarsino, Gina; Hirschhorn, Lisa R
2017-05-01
Primary health care (PHC) has been recognized as a core component of effective health systems since the early part of the twentieth century. However, despite notable progress, there remains a large gap between what individuals and communities need, and the quality and effectiveness of care delivered. The Primary Health Care Performance Initiative (PHCPI) was established by an international consortium to catalyze improvements in PHC delivery and outcomes in low- and middle-income countries through better measurement and sharing of effective models and practices. PHCPI has developed a framework to illustrate the relationship between key financing, workforce, and supply inputs, and core primary health care functions of first-contact accessibility, comprehensiveness, coordination, continuity, and person-centeredness. The framework provides guidance for more effective assessment of current strengths and gaps in PHC delivery through a core set of 25 key indicators ("Vital Signs"). Emerging best practices that foster high-performing PHC system development are being codified and shared around low- and high-income countries. These measurement and improvement approaches provide countries and implementers with tools to assess the current state of their PHC delivery system and to identify where cross-country learning can accelerate improvements in PHC quality and effectiveness.
Multi-range force sensors utilizing shape memory alloys
Varma, Venugopal K.
2003-04-15
The present invention provides a multi-range force sensor comprising a load cell made of a shape memory alloy, a strain sensing system, a temperature modulating system, and a temperature monitoring system. The ability of the force sensor to measure contact forces in multiple ranges is effected by the change in temperature of the shape memory alloy. The heating and cooling system functions to place the shape memory alloy of the load cell in either a low temperature, low strength phase for measuring small contact forces, or a high temperature, high strength phase for measuring large contact forces. Once the load cell is in the desired phase, the strain sensing system is utilized to obtain the applied contact force. The temperature monitoring system is utilized to ensure that the shape memory alloy is in one phase or the other.
NASA Astrophysics Data System (ADS)
Gangeh, Mehrdad J.; Fung, Brandon; Tadayyon, Hadi; Tran, William T.; Czarnota, Gregory J.
2016-03-01
A non-invasive computer-aided-theragnosis (CAT) system was developed for the early assessment of responses to neoadjuvant chemotherapy in patients with locally advanced breast cancer. The CAT system was based on quantitative ultrasound spectroscopy methods comprising several modules including feature extraction, a metric to measure the dissimilarity between "pre-" and "mid-treatment" scans, and a supervised learning algorithm for the classification of patients to responders/non-responders. One major requirement for the successful design of a high-performance CAT system is to accurately measure the changes in parametric maps before treatment onset and during the course of treatment. To this end, a unified framework based on Hilbert-Schmidt independence criterion (HSIC) was used for the design of feature extraction from parametric maps and the dissimilarity measure between the "pre-" and "mid-treatment" scans. For the feature extraction, HSIC was used to design a supervised dictionary learning (SDL) method by maximizing the dependency between the scans taken from "pre-" and "mid-treatment" with "dummy labels" given to the scans. For the dissimilarity measure, an HSIC-based metric was employed to effectively measure the changes in parametric maps as an indication of treatment effectiveness. The HSIC-based feature extraction and dissimilarity measure used a kernel function to nonlinearly transform input vectors into a higher dimensional feature space and computed the population means in the new space, where enhanced group separability was ideally obtained. The results of the classification using the developed CAT system indicated an improvement of performance compared to a CAT system with basic features using histogram of intensity.
Zhou, Qifan; Zhang, Hai; Li, You; Li, Zheng
2015-01-01
The main aim of this paper is to develop a low-cost GNSS/MEMS-IMU tightly-coupled integration system with aiding information that can provide reliable position solutions when the GNSS signal is challenged such that less than four satellites are visible in a harsh environment. To achieve this goal, we introduce an adaptive tightly-coupled integration system with height and heading aiding (ATCA). This approach adopts a novel redundant measurement noise estimation method for an adaptive Kalman filter application and also augments external measurements in the filter to aid the position solutions, as well as uses different filters to deal with various situations. On the one hand, the adaptive Kalman filter makes use of the redundant measurement system’s difference sequence to estimate and tune noise variance instead of employing a traditional innovation sequence to avoid coupling with the state vector error. On the other hand, this method uses the external height and heading angle as auxiliary references and establishes a model for the measurement equation in the filter. In the meantime, it also changes the effective filter online based on the number of tracked satellites. These measures have increasingly enhanced the position constraints and the system observability, improved the computational efficiency and have led to a good result. Both simulated and practical experiments have been carried out, and the results demonstrate that the proposed method is effective at limiting the system errors when there are less than four visible satellites, providing a satisfactory navigation solution. PMID:26393605
An autonomous unmanned aerial vehicle sensing system for structural health monitoring of bridges
NASA Astrophysics Data System (ADS)
Reagan, Daniel; Sabato, Alessandro; Niezrecki, Christopher; Yu, Tzuyang; Wilson, Richard
2016-04-01
As civil infrastructure (i.e. bridges, railways, and tunnels) continues to age; the frequency and need to perform inspection more quickly on a broader scale increases. Traditional inspection and monitoring techniques (e.g., visual inspection, mechanical sounding, rebound hammer, cover meter, electrical potential measurements, ultrasound, and ground penetrating radar) may produce inconsistent results, require lane closure, are labor intensive and time-consuming. Therefore, new structural health monitoring systems must be developed that are automated, highly accurate, minimally invasive, and cost effective. Three-dimensional (3D) digital image correlation (DIC) systems have the merits of extracting full-field strain, deformation, and geometry profiles. These profiles can then be stitched together to generate a complete integrity map of the area of interest. Concurrently, unmanned aerial vehicles (UAVs) have emerged as valuable resources for positioning sensing equipment where it is either difficult to measure or poses a risk to human safety. UAVs have the capability to expedite the optical-based measurement process, offer increased accessibility, and reduce interference with local traffic. Within this work, an autonomous unmanned aerial vehicle in conjunction with 3D DIC was developed for monitoring bridges. The capabilities of the proposed system are demonstrated in both laboratory measurements and data collected from bridges currently in service. Potential measurement influences from platform instability, rotor vibration and positioning inaccuracy are also studied in a controlled environment. The results of these experiments show that the combination of autonomous flight with 3D DIC and other non-contact measurement systems provides a valuable and effective civil inspection platform.
Liu, Shi Qiang; Zhu, Rong
2016-01-01
Errors compensation of micromachined-inertial-measurement-units (MIMU) is essential in practical applications. This paper presents a new compensation method using a neural-network-based identification for MIMU, which capably solves the universal problems of cross-coupling, misalignment, eccentricity, and other deterministic errors existing in a three-dimensional integrated system. Using a neural network to model a complex multivariate and nonlinear coupling system, the errors could be readily compensated through a comprehensive calibration. In this paper, we also present a thermal-gas MIMU based on thermal expansion, which measures three-axis angular rates and three-axis accelerations using only three thermal-gas inertial sensors, each of which capably measures one-axis angular rate and one-axis acceleration simultaneously in one chip. The developed MIMU (100 × 100 × 100 mm3) possesses the advantages of simple structure, high shock resistance, and large measuring ranges (three-axes angular rates of ±4000°/s and three-axes accelerations of ±10 g) compared with conventional MIMU, due to using gas medium instead of mechanical proof mass as the key moving and sensing elements. However, the gas MIMU suffers from cross-coupling effects, which corrupt the system accuracy. The proposed compensation method is, therefore, applied to compensate the system errors of the MIMU. Experiments validate the effectiveness of the compensation, and the measurement errors of three-axis angular rates and three-axis accelerations are reduced to less than 1% and 3% of uncompensated errors in the rotation range of ±600°/s and the acceleration range of ±1 g, respectively. PMID:26840314
FEL investigations of energy transfer in condensed phase systems
NASA Astrophysics Data System (ADS)
Henderson, Don O.; Mu, Richard; Silberman, Enrique; Johnson, J. B.; Edwards, Glenn S.
1993-07-01
The vibrational dynamics of O-H groups in fused silica have been examined by a time- resolved pump-probe technique using the Vanderbilt Free Electron Laser (FEL). We consider two effects, local heating and transient thermal lensing, which can influence measured T1 values in one color pump-probe measurements. The dependence of these two effects on both the micropulse spacing and the total number of micropulses delivered to the sample are analyzed in detail for the O-H/SiO2 system. The results indicate that transient thermal lensing can significantly influence the measured probe signal. The local heating may cause thermally induced changes in the ground state population of the absorber, thereby complicating the analysis of the relaxation dynamics.
NASA Astrophysics Data System (ADS)
Foley, E. L.; Levinton, F. M.
2013-04-01
The motional Stark effect with laser-induced fluorescence diagnostic (MSE-LIF) has been installed and tested on the National Spherical Torus Experiment (NSTX) at the Princeton Plasma Physics Lab. The MSE-LIF diagnostic will be capable of measuring radially resolved profiles of magnetic field magnitude or pitch angle in NSTX plasmas. The system includes a diagnostic neutral hydrogen beam and a laser which excites the n = 2 to n = 3 transition. A viewing system has been implemented which will support up to 38 channels from the plasma edge to past the magnetic axis. First measurements of MSE-LIF signals in the presence of small applied magnetic fields in neutral gas are reported.
Simulations of initial MHD experiments on the Madison Dynamo Experiment
NASA Astrophysics Data System (ADS)
O'Connell, R.; Forest, C. B.; Goldwin, J. M.; Kendrick, R. D.; Canary, H. W.; Nornberg, M. D.; Jaun, A.
1999-11-01
Initial experiments for a liquid metal MHD device have been modelled using measurements from geometrically similar water experiments. In the low B limit the water flows are the same as sodium flows. Two codes have been written to predict 1) linear stability of the system and 2) the response of the system to an externally applied vertical magnetic field, using measured velocity profiles. Predictions are made for a first set of MHD experiments, including: a) demonstration of the distortion and amplification of externally applied magnetic fields by sheared flows, b) demonstration of the β-effect by measurement of the turbulent conductivity, c) demonstration of a turbulent α effect and d) characterization of magnetic eigenmodes.
Design of measuring system for wire diameter based on sub-pixel edge detection algorithm
NASA Astrophysics Data System (ADS)
Chen, Yudong; Zhou, Wang
2016-09-01
Light projection method is often used in measuring system for wire diameter, which is relatively simpler structure and lower cost, and the measuring accuracy is limited by the pixel size of CCD. Using a CCD with small pixel size can improve the measuring accuracy, but will increase the cost and difficulty of making. In this paper, through the comparative analysis of a variety of sub-pixel edge detection algorithms, polynomial fitting method is applied for data processing in measuring system for wire diameter, to improve the measuring accuracy and enhance the ability of anti-noise. In the design of system structure, light projection method with orthogonal structure is used for the detection optical part, which can effectively reduce the error caused by line jitter in the measuring process. For the electrical part, ARM Cortex-M4 microprocessor is used as the core of the circuit module, which can not only drive double channel linear CCD but also complete the sampling, processing and storage of the CCD video signal. In addition, ARM microprocessor can complete the high speed operation of the whole measuring system for wire diameter in the case of no additional chip. The experimental results show that sub-pixel edge detection algorithm based on polynomial fitting can make up for the lack of single pixel size and improve the precision of measuring system for wire diameter significantly, without increasing hardware complexity of the entire system.
Casner, Stephen M
2009-05-01
Four types of advanced cockpit systems were tested in an in-flight experiment for their effect on pilot workload and error. Twelve experienced pilots flew conventional cockpit and advanced cockpit versions of the same make and model airplane. In both airplanes, the experimenter dictated selected combinations of cockpit systems for each pilot to use while soliciting subjective workload measures and recording any errors that pilots made. The results indicate that the use of a GPS navigation computer helped reduce workload and errors during some phases of flight but raised them in others. Autopilots helped reduce some aspects of workload in the advanced cockpit airplane but did not appear to reduce workload in the conventional cockpit. Electronic flight and navigation instruments appeared to have no effect on workload or error. Despite this modest showing for advanced cockpit systems, pilots stated an overwhelming preference for using them during all phases of flight.
Experimental evaluation of ontology-based HIV/AIDS frequently asked question retrieval system.
Ayalew, Yirsaw; Moeng, Barbara; Mosweunyane, Gontlafetse
2018-05-01
This study presents the results of experimental evaluations of an ontology-based frequently asked question retrieval system in the domain of HIV and AIDS. The main purpose of the system is to provide answers to questions on HIV/AIDS using ontology. To evaluate the effectiveness of the frequently asked question retrieval system, we conducted two experiments. The first experiment focused on the evaluation of the quality of the ontology we developed using the OQuaRE evaluation framework which is based on software quality metrics and metrics designed for ontology quality evaluation. The second experiment focused on evaluating the effectiveness of the ontology in retrieving relevant answers. For this we used an open-source information retrieval platform, Terrier, with retrieval models BM25 and PL2. For the measurement of performance, we used the measures mean average precision, mean reciprocal rank, and precision at 5. The results suggest that frequently asked question retrieval with ontology is more effective than frequently asked question retrieval without ontology in the domain of HIV/AIDS.
NASA Technical Reports Server (NTRS)
Liu, Dahai; Goodrich, Kenneth H.; Peak, Bob
2010-01-01
This study investigated the effects of synthetic vision system (SVS) concepts and advanced flight controls on the performance of pilots flying a light, single-engine general aviation airplane. We evaluated the effects and interactions of two levels of terrain portrayal, guidance symbology, and flight control response type on pilot performance during the conduct of a relatively complex instrument approach procedure. The terrain and guidance presentations were evaluated as elements of an integrated primary flight display system. The approach procedure used in the study included a steeply descending, curved segment as might be encountered in emerging, required navigation performance (RNP) based procedures. Pilot performance measures consisted of flight technical performance, perceived workload, perceived situational awareness and subjective preference. The results revealed that an elevation based generic terrain portrayal significantly improved perceived situation awareness without adversely affecting flight technical performance or workload. Other factors (pilot instrument rating, control response type, and guidance symbology) were not found to significantly affect the performance measures.
Al Mohtar, Abeer; Kazan, Michel; Taliercio, Thierry; Cerutti, Laurent; Blaize, Sylvain; Bruyant, Aurélien
2017-03-24
We have investigated the effective dielectric response of a subwavelength grating made of highly doped semiconductors (HDS) excited in reflection, using numerical simulations and spectroscopic measurement. The studied system can exhibit strong localized surface resonances and has, therefore, a great potential for surface-enhanced infrared absorption (SEIRA) spectroscopy application. It consists of a highly doped InAsSb grating deposited on lattice-matched GaSb. The numerical analysis demonstrated that the resonance frequencies can be inferred from the dielectric function of an equivalent homogeneous slab by accounting for the complex reflectivity of the composite layer. Fourier transform infrared reflectivity (FTIR) measurements, analyzed with the Kramers-Kronig conversion technique, were used to deduce the effective response in reflection of the investigated system. From the knowledge of this phenomenological dielectric function, transversal and longitudinal energy-loss functions were extracted and attributed to transverse and longitudinal resonance modes frequencies.
Construction of Gallium Point at NMIJ
NASA Astrophysics Data System (ADS)
Widiatmo, J. V.; Saito, I.; Yamazawa, K.
2017-03-01
Two open-type gallium point cells were fabricated using ingots whose nominal purities are 7N. Measurement systems for the realization of the melting point of gallium using these cells were built. The melting point of gallium is repeatedly realized by means of the measurement systems for evaluating the repeatability. Measurements for evaluating the effect of hydrostatic pressure coming from the molten gallium existing during the melting process and the effect of gas pressure that fills the cell were also performed. Direct cell comparisons between those cells were conducted. This comparison was aimed to evaluate the consistency of each cell, especially related to the nominal purity. Direct cell comparison between the open-type and the sealed-type gallium point cell was also conducted. Chemical analysis was conducted using samples extracted from ingots used in both the newly built open-type gallium point cells, from which the effect of impurities in the ingot was evaluated.
NASA Astrophysics Data System (ADS)
Wang, Tao; Huang, Peng; Zhou, Yingming; Liu, Weiqi; Zeng, Guihua
2018-01-01
In a practical continuous-variable quantum key distribution (CVQKD) system, real-time shot-noise measurement (RTSNM) is an essential procedure for preventing the eavesdropper exploiting the practical security loopholes. However, the performance of this procedure itself is not analyzed under the real-world condition. Therefore, we indicate the RTSNM practical performance and investigate its effects on the CVQKD system. In particular, due to the finite-size effect, the shot-noise measurement at the receiver's side may decrease the precision of parameter estimation and consequently result in a tight security bound. To mitigate that, we optimize the block size for RTSNM under the ensemble size limitation to maximize the secure key rate. Moreover, the effect of finite dynamics of amplitude modulator in this scheme is studied and its mitigation method is also proposed. Our work indicates the practical performance of RTSNM and provides the real secret key rate under it.
Analysis of aircraft microwave measurements of the ocean surface
NASA Technical Reports Server (NTRS)
Willand, J. H.; Fowler, M. G.; Reifenstein, E. C., III; Chang, D. T.
1973-01-01
A data system was developed to process, from calibrated brightness temperature to computation of estimated parameters, the microwave measurements obtained by the NASA CV-990 aircraft during the 1972 Meteorological Expedition. A primary objective of the study was the implementation of an integrated software system at the computing facility of NASA/GSFC, and its application to the 1972 data. A single test case involving measurements away from and over a heavy rain cell was chosen to examine the effect of clouds upon the ability to infer ocean surface parameters. The results indicate substantial agreement with those of the theoretical study; namely, that the values obtained for the surface properties are consistent with available ground-truth information, and are reproducible except within the heaviest portions of the rain cell, at which nonlinear (or saturation) effects become apparent. Finally, it is seen that uncorrected instrumental effects introduce systematic errors which may limit the accuracy of the method.
NASA Astrophysics Data System (ADS)
Haneda, Kiyofumi; Koyama, Tadashi
2005-04-01
We developed a secure system that minimizes staff workload and secures safety of a medical information system. In this study, we assess the legal security requirements and risks occurring from the use of digitized data. We then analyze the security measures for ways of reducing these risks. In the analysis, not only safety, but also costs of security measures and ease of operability are taken into consideration. Finally, we assess the effectiveness of security measures by employing our system in small-sized medical institution. As a result of the current study, we developed and implemented several security measures, such as authentications, cryptography, data back-up, and secure sockets layer protocol (SSL) in our system. In conclusion, the cost for the introduction and maintenance of a system is one of the primary difficulties with its employment by a small-sized institution. However, with recent reductions in the price of computers, and certain advantages of small-sized medical institutions, the development of an efficient system configuration has become possible.
NASA Astrophysics Data System (ADS)
Sun, Yushi; Udpa, Satish; Lord, William; Udpa, Lalita; Ouyang, Tianhe
2001-04-01
The Motion Induced Remote-Field Eddy-Current (MIRFEC) effect was first observed in 1994. The effect was first exploited for detecting pipeline stress corrosion cracks as a part of a research project sponsored by the U.S. Department of Transportation. This paper presents a new application of the MIRFEC effect for online inspection of rolling metallic strips. Currently, rolled metallic strips and sheets are inspected off-line, which is costly, time consuming and not ideal for quality control. A well-designed online diagnostic and control system for metal rolling process may be able to reduce cost, improve quality, and hence enhance competitiveness of the product. The overall objective of this paper is to demonstrate the feasibility of a new nondestructive measurement system for on-line diagnostics and control of metallic rolling process using the MIRFEC effect. The system can be used to monitor, in real time, metallic strips/sheets for possible anomalies, inclusions, voids, bubbles, lamination, as well as variations in its magnetic and other properties. The potential advantages of the MIRFEC system include simplicity, robustness, low cost, high reliability, quick and accurate signal classification and characterization. Such systems can be used for real-time process control, or off-line data analysis. The technique also allows operation at high temperatures, tolerates large lift-off and vibration, and high rolling speed. Results of finite element modeling of the MIRFEC effect and experimental measurement data obtained from a prototype system are presented.
Northey, G W; Oliver, M L; Rittenhouse, D M
2006-01-01
Biomechanics studies often require the analysis of position and orientation. Although a variety of transducer and camera systems can be utilized, a common inexpensive alternative is the Hall effect sensor. Hall effect sensors have been used extensively for one-dimensional position analysis but their non-linear behavior and cross-talk effects make them difficult to calibrate for effective and accurate two- and three-dimensional position and orientation analysis. The aim of this study was to develop and calibrate a displacement measurement system for a hydraulic-actuation joystick used for repetitive motion analysis of heavy equipment operators. The system utilizes an array of four Hall effect sensors that are all active during any joystick movement. This built-in redundancy allows the calibration to utilize fully connected feed forward neural networks in conjunction with a Microscribe 3D digitizer. A fully connected feed forward neural network with one hidden layer containing five neurons was developed. Results indicate that the ability of the neural network to accurately predict the x, y and z coordinates of the joystick handle was good with r(2) values of 0.98 and higher. The calibration technique was found to be equally as accurate when used on data collected 5 days after the initial calibration, indicating the system is robust and stable enough to not require calibration every time the joystick is used. This calibration system allowed an infinite number of joystick orientations and positions to be found within the range of joystick motion.
ANISOTROPY DETERMINATIONS IN EXCHANGE SPRING MAGNETS.
DOE Office of Scientific and Technical Information (OSTI.GOV)
LEWIS,L.H.; HARLAND,C.L.
2002-08-18
Ferromagnetic nanocomposites, or ''exchange spring'' magnets, possess a nanoscaled microstructure that allows intergrain magnetic exchange forces to couple the constituent grains and alter the system's effective magnetic anisotropies. While the effects of the anisotropy alterations are clearly seen in macroscopic magnetic measurement, it is extremely difficult to determine the detailed effects of the system's exchange coupling, such as the interphase exchange length, the inherent domain wall widths or the effective anisotropies of the system. Clarification of these materials parameters may be obtained from the ''micromagnetic'' phenomenological model, where the assumption of magnetic reversal initiating in the magnetically-soft regions of themore » exchange-spring maqet is explicitly included. This approach differs from that typically applied by other researchers and allows a quantitative estimate of the effective anisotropies of an exchange spring system. Hysteresis loops measured on well-characterized nanocomposite alloys based on the composition Nd{sub 2}Fe{sub 14}B + {alpha}-Fe at temperatures above the spin reorientation temperature were analyzed within the framework of the micromagnetic phenomenological model. Preliminary results indicate that the effective anisotropy constant in the material is intermediate to that of bulk {alpha}-Fe and bulk Nd{sub 2}Fe{sub 14}B and increases with decreasing temperature. These results strongly support the idea that magnetic reversal in nanocomposite systems initiates in the lower-anisotropy regions of the system, and that the soft-phase regions become exchange-hardened by virtue of their proximity to the magnetically-hard regions.« less
Video integrated measurement system. [Diagnostic display devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Spector, B.; Eilbert, L.; Finando, S.
A Video Integrated Measurement (VIM) System is described which incorporates the use of various noninvasive diagnostic procedures (moire contourography, electromyography, posturometry, infrared thermography, etc.), used individually or in combination, for the evaluation of neuromusculoskeletal and other disorders and their management with biofeedback and other therapeutic procedures. The system provides for measuring individual diagnostic and therapeutic modes, or multiple modes by split screen superimposition, of real time (actual) images of the patient and idealized (ideal-normal) models on a video monitor, along with analog and digital data, graphics, color, and other transduced symbolic information. It is concluded that this system provides anmore » innovative and efficient method by which the therapist and patient can interact in biofeedback training/learning processes and holds considerable promise for more effective measurement and treatment of a wide variety of physical and behavioral disorders.« less
Laser Measurements Based for Volumetric Accuracy Improvement of Multi-axis Systems
NASA Astrophysics Data System (ADS)
Vladimir, Sokolov; Konstantin, Basalaev
The paper describes a new developed approach to CNC-controlled multi-axis systems geometric errors compensation based on optimal error correction strategy. Multi-axis CNC-controlled systems - machine-tools and CMM's are the basis of modern engineering industry. Similar design principles of both technological and measurement equipment allow usage of similar approaches to precision management. The approach based on geometric errors compensation are widely used at present time. The paper describes a system for compensation of geometric errors of multi-axis equipment based on the new approach. The hardware basis of the developed system is a multi-function laser interferometer. The principles of system's implementation, results of measurements and system's functioning simulation are described. The effectiveness of application of described principles to multi-axis equipment of different sizes and purposes for different machining directions and zones within workspace is presented. The concepts of optimal correction strategy is introduced and dynamic accuracy control is proposed.
Acceleration Environment of the International Space Station
NASA Technical Reports Server (NTRS)
McPherson, Kevin; Kelly, Eric; Keller, Jennifer
2009-01-01
Measurement of the microgravity acceleration environment on the International Space Station has been accomplished by two accelerometer systems since 2001. The Microgravity Acceleration Measurement System records the quasi-steady microgravity environment, including the influences of aerodynamic drag, vehicle rotation, and venting effects. Measurement of the vibratory/transient regime, comprised of vehicle, crew, and equipment disturbances, has been accomplished by the Space Acceleration Measurement System-II. Until the arrival of the Columbus Orbital Facility and the Japanese Experiment Module, the location of these sensors, and therefore, the measurement of the microgravity acceleration environment, has been limited to within the United States Laboratory. Japanese Aerospace Exploration Agency has developed a vibratory acceleration measurement system called the Microgravity Measurement Apparatus which will be deployed within the Japanese Experiment Module to make distributed measurements of the Japanese Experiment Module's vibratory acceleration environment. Two Space Acceleration Measurement System sensors from the United States Laboratory will be re-deployed to support vibratory acceleration data measurement within the Columbus Orbital Facility. The additional measurement opportunities resulting from the arrival of these new laboratories allows Principal Investigators with facilities located in these International Space Station research laboratories to obtain microgravity acceleration data in support of their sensitive experiments. The Principal Investigator Microgravity Services project, at NASA Glenn Research Center, in Cleveland, Ohio, has supported acceleration measurement systems and the microgravity scientific community through the processing, characterization, distribution, and archival of the microgravity acceleration data obtained from the International Space Station acceleration measurement systems. This paper summarizes the PIMS capabilities available to the International Space Station scientific community, introduces plans for extending microgravity analysis results to the newly arrived scientific laboratories, and provides summary information for known microgravity environment disturbers.
Code of Federal Regulations, 2014 CFR
2014-07-01
... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...
Code of Federal Regulations, 2012 CFR
2012-07-01
... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...