Kim, Pyeong Hwa; Song, Ho-Young; Park, Jung-Hoon; Zhou, Wei-Zhong; Na, Han Kyu; Cho, Young Chul; Jun, Eun Jung; Kim, Jun Ki; Kim, Guk Bae
2017-03-01
To evaluate clinical outcomes of fluoroscopic removal of retrievable self-expandable metal stents (SEMSs) for malignant oesophageal strictures, to compare clinical outcomes of three different removal techniques, and to identify predictive factors of successful removal by the standard technique (primary technical success). A total of 137 stents were removed from 128 patients with malignant oesophageal strictures. Primary overall technical success and removal-related complications were evaluated. Logistic regression models were constructed to identify predictive factors of primary technical success. Primary technical success rate was 78.8 % (108/137). Complications occurred in six (4.4 %) cases. Stent location in the upper oesophagus (P=0.004), stricture length over 8 cm (P=0.030), and proximal granulation tissue (P<0.001) were negative predictive factors of primary technical success. If granulation tissue was present at the proximal end, eversion technique was more frequently required (P=0.002). Fluoroscopic removal of retrievable SEMSs for malignant oesophageal strictures using three different removal techniques appeared to be safe and easy. The standard technique is safe and effective in the majority of patients. The presence of proximal granulation tissue, stent location in the upper oesophagus, and stricture length over 8 cm were negative predictive factors for primary technical success by standard extraction and may require a modified removal technique. • Fluoroscopic retrievable SEMS removal is safe and effective. • Standard removal technique by traction is effective in the majority of patients. • Three negative predictive factors of primary technical success were identified. • Caution should be exercised during the removal in those situations. • Eversion technique is effective in cases of proximal granulation tissue.
When properly conducted, sediment removal is an effective lake management technique. This chapter describes: (1) purposes of sediment removal, (2) environmental concerns, (3) appropriate depth of sediment removal, (4) sediment removal techniques, (5) suitable lake conditions, (6)...
MANAGEMENT OF LAKES THROUGH SEDIMENT REMOVAL
When properly conducted, sediment removal is an effective lake management technique. This paper describes: (1) the purpose of sediment removal, (2) environmental concerns, (3) depth of sediment removal, (4) sediment removal techniques, (5) suitable lake conditions, (6) exemplary ...
Jumbo Cutter for Removal of A Bent Femoral Interlocking Nail: A Cost Effective Method
Dhanda, Manjeet Singh; Sharma, Sansar C; Ali, Nadeem; Bhat, Abedullah
2015-01-01
Closed diaphyseal femoral shaft fractures can be treated with multiple surgical options. It is more challenging to remove a bent nail than a broken one because it is difficult to retrieve the bent nail through the intramedullary canal. Various authors have published their techniques for removal of bent femoral interlocking nail. This article describes a simple technique using Jumbo cutter for sectioning and removal of bent interlocking nail. This technique will help orthopaedic surgeons to remove bent nail without using any specialised metal cutting instruments. PMID:26266173
Combined tool approach is 100% successful for emergency football face mask removal.
Copeland, Aaron J; Decoster, Laura C; Swartz, Erik E; Gattie, Eric R; Gale, Stephanie D
2007-11-01
To compare effectiveness of two techniques for removing football face masks: cutting loop straps [cutting tool: FMXtractor (FMX)] or removing screws with a cordless screwdriver and using the FMXtractor as needed for failed removals [combined tool (CT)]. Null hypotheses: no differences in face mask removal success, removal time or difficulty between techniques or helmet characteristics. Retrospective, cross-sectional. NOCSAE-certified helmet reconditioning plants. 600 used high school helmets. Face mask removal attempted with two techniques. Success, removal time, rating of perceived exertion (RPE). Both techniques were effective [CT 100% (300/300); FMX 99.4% (298/300)]. Use of the backup FMXtractor in CT trials was required in 19% of trials. There was significantly (P<0.001) less call for the backup tool in helmets with silver screws (6%) than in helmets with other screws (31%). Mean removal time was 44.51+/-18.79s (CT: 37.84+/-15.37s, FMX: 51.21+/-19.54s; P<0.001). RPE was different between techniques (CT: 1.83+/-1.20, FMX: 3.11+/-1.27; P<0.001). Removal from helmets with silver screws was faster (Silver=33.38+/-11.03, Others=42.18+/-17.64; P<0.001) and easier (Silver=1.42+/-0.89, Other=2.23+/-1.33; P<0.001). CT was faster and easier than FMX. Most CT trials were completed with the screwdriver alone; helmets with silver screws had 94% screwdriver success. Clinically, these findings are important because this and other research shows that compared to removal with cutting tools, screwdriver removal decreases time, difficulty and helmet movement (reducing potential for iatrogenic injury). The combined-tool approach captures benefits of the screwdriver while offering a contingency for screw removal failure. Teams should use degradation-resistant screws. Sports medicine professionals must be prepared with appropriate tools and techniques to efficiently remove the face mask from an injured football player's helmet.
Comparison of residual NAPL source removal techniques in 3D metric scale experiments
NASA Astrophysics Data System (ADS)
Atteia, O.; Jousse, F.; Cohen, G.; Höhener, P.
2017-07-01
This study compared four treatment techniques for the removal of a toluene/n-decane as NAPL (Non Aqueous Phase Liquid) phase mixture in identical 1 cubic meter tanks filled with different kind of sand. These four treatment techniques were: oxidation with persulfate, surfactant washing with Tween80®, sparging with air followed by ozone, and thermal treatment at 80 °C. The sources were made with three lenses of 26 × 26 × 6.5 cm, one having a hydraulic conductivity similar to the whole tank and the two others a value 10 times smaller. The four techniques were studied after conditioning the tanks with tap water during approximately 80 days. The persulfate treatment tests showed average removal of the contaminants but significant flux decrease if density effects are considered. Surfactant flushing did not show a highly significant increase of the flux of toluene but allowed an increased removal rate that could lead to an almost complete removal with longer treatment time. Sparging removed a significant amount but suggests that air was passing through localized gas channels and that the removal was stagnating after removing half of the contamination. Thermal treatment reached 100% removal after the target temperature of 80 °C was kept during more than 10 d. The experiments emphasized the generation of a high-spatial heterogeneity in NAPL content. For all the treatments the overall removal was similar for both n-decane and toluene, suggesting that toluene was removed rapidly and n-decane more slowly in some zones, while no removal existed in other zones. The oxidation and surfactant results were also analyzed for the relation between contaminant fluxes at the outlet and mass removal. For the first time, this approach clearly allowed the differentiation of the treatments. As a conclusion, experiments showed that the most important differences between the tested treatment techniques were not the global mass removal rates but the time required to reach 99% decrease in the contaminant fluxes, which were different for each technique. This paper presents the first comparison of four remediation techniques at the scale of 1 m3 tanks including heterogeneities. Sparging, persulfate and surfactant only remove 50% of the mass, while it is more than 99% for thermal. In terms of flux removal oxidant addition performs better when density effects are used.
Latest innovations for tattoo and permanent makeup removal.
Mao, Johnny C; DeJoseph, Louis M
2012-05-01
The goal of this article is to reveal the latest techniques and advances in laser removal of both amateur and professional tattoos, as well as cosmetic tattoos and permanent makeup. Each pose different challenges to the removing physician, but the goal is always the same: removal without sequelae. The authors' technique is detailed, and discussion of basic principles of light reflection, ink properties, effects of laser energy and heat, and outcomes and complications of tattoo removal are presented. Copyright © 2012 Elsevier Inc. All rights reserved.
How Effective are Existing Arsenic Removal Techniques
This presentation will summarize the system performance results of the technologies demonstrated in the arsenic demonstration program. The technologies include adsorptive media, iron removal, iron removal with iron additions, iron removal followed by adsorptive media, coagulatio...
Glucagon Is a Safe and Inexpensive Initial Strategy in Esophageal Food Bolus Impaction.
Haas, Jason; Leo, Julia; Vakil, Nimish
2016-03-01
Controversy exists about the utility of pharmacologic agents and endoscopic technique used for esophageal food bolus impaction. To evaluate the utility of glucagon and the technique used for endoscopic removal, including the rate of success and the adverse events of the techniques. The database of the largest healthcare provider in southeastern Wisconsin was retrospectively reviewed for patients presenting with esophageal food bolus impaction. Data extracted included glucagon administration and its success rate, outcome of radiographic studies, and the endoscopic method of removal and adverse events associated with it, including 30-day mortality. A total of 750 patients were identified with food bolus impaction from 2007 to 2012. Glucagon was administered in 440 patients and was successful in 174 (39.5%). Endoscopic removal was performed in 470 patients and was successful in 469 (99.8%). The push technique was utilized in 209 patients, reduction in the bolus size by piecemeal removal followed by the push technique was utilized in 97 patients, and the pull technique was utilized in 107 patients. There were no perforations with endoscopic removal. Only 4.5% of the X-rays performed reported a possible foreign body within the esophagus. Glucagon was a significantly less-expensive strategy than endoscopic therapy (p < 0.0001). Glucagon is low cost, is moderately effective, and may be considered as an initial strategy. Endoscopic removal regardless of technique is safe and effective. The yield of radiography is poor in the setting of food bolus impaction.
Anderson, Andrew; Tollefson, Brian; Cohen, Rob; Johnson, Jeremy; Summers, Richard L
2011-04-01
American football is the source of a significant number of cervical spine injuries. Removal of the helmets from these individuals is often problematic and presents a potential for exacerbation of the injury. There are two widely recognized helmet removal techniques that are currently in practice. In this study, the two methods are compared for cervical movement and potential for cord injury to determine their relative efficiency and clinical utility. A single cadaver with a simulated cervical injury was used to compare the National Athletic Trainers' Association (NATA) and cast saw techniques of helmet removal. Directed lateral fluoroscopy was used to measure the relative changes in angulation, translation, distraction, and space available to the spinal cord during helmet removal using the two techniques as performed by medical personnel with limited training in the methods. By radiologists' reports, there were no detectable changes in disc height, translation or space available for the spinal cord during helmet removal with either of the studied techniques. Operators noted that the noise of the cast saw would probably be significantly uncomfortable for any live subject inside of a helmet. Both the NATA and cast saw methods appear effective for the safe removal of a football helmet and with little risk of further injury to the cervical spine. Considering the simplicity and efficiency of the NATA helmet removal technique, the authors conclude that the NATA technique should be the preferred helmet removal method.
Effect of volatile removal during molding on the properties of two phenolic-fiber composites
NASA Technical Reports Server (NTRS)
Price, H. L.; Lucy, M. H.
1974-01-01
A comparison has been made of the effect of three volatile-removing techniques during molding on the properties of phenolic-fiber composites. The first technique involved heating the molding compound from one side, initiating the volatile-producing reactions, and driving these volatiles through the compound toward the cooler side. The second technique involved the application of a vacuum to the molding cavity before and during the cure cycle. The third technique was a combination of the first two. These techniques were used in the compression molding of phenolic-asbestos and phenolic-glass composites. The effects of both the individual and combined techniques on the mechanical, thermal, and sorption properties of the composites are reported.
Evaluation of normalization methods for cDNA microarray data by k-NN classification
Wu, Wei; Xing, Eric P; Myers, Connie; Mian, I Saira; Bissell, Mina J
2005-01-01
Background Non-biological factors give rise to unwanted variations in cDNA microarray data. There are many normalization methods designed to remove such variations. However, to date there have been few published systematic evaluations of these techniques for removing variations arising from dye biases in the context of downstream, higher-order analytical tasks such as classification. Results Ten location normalization methods that adjust spatial- and/or intensity-dependent dye biases, and three scale methods that adjust scale differences were applied, individually and in combination, to five distinct, published, cancer biology-related cDNA microarray data sets. Leave-one-out cross-validation (LOOCV) classification error was employed as the quantitative end-point for assessing the effectiveness of a normalization method. In particular, a known classifier, k-nearest neighbor (k-NN), was estimated from data normalized using a given technique, and the LOOCV error rate of the ensuing model was computed. We found that k-NN classifiers are sensitive to dye biases in the data. Using NONRM and GMEDIAN as baseline methods, our results show that single-bias-removal techniques which remove either spatial-dependent dye bias (referred later as spatial effect) or intensity-dependent dye bias (referred later as intensity effect) moderately reduce LOOCV classification errors; whereas double-bias-removal techniques which remove both spatial- and intensity effect reduce LOOCV classification errors even further. Of the 41 different strategies examined, three two-step processes, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, all of which removed intensity effect globally and spatial effect locally, appear to reduce LOOCV classification errors most consistently and effectively across all data sets. We also found that the investigated scale normalization methods do not reduce LOOCV classification error. Conclusion Using LOOCV error of k-NNs as the evaluation criterion, three double-bias-removal normalization strategies, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, outperform other strategies for removing spatial effect, intensity effect and scale differences from cDNA microarray data. The apparent sensitivity of k-NN LOOCV classification error to dye biases suggests that this criterion provides an informative measure for evaluating normalization methods. All the computational tools used in this study were implemented using the R language for statistical computing and graphics. PMID:16045803
Evaluation of normalization methods for cDNA microarray data by k-NN classification.
Wu, Wei; Xing, Eric P; Myers, Connie; Mian, I Saira; Bissell, Mina J
2005-07-26
Non-biological factors give rise to unwanted variations in cDNA microarray data. There are many normalization methods designed to remove such variations. However, to date there have been few published systematic evaluations of these techniques for removing variations arising from dye biases in the context of downstream, higher-order analytical tasks such as classification. Ten location normalization methods that adjust spatial- and/or intensity-dependent dye biases, and three scale methods that adjust scale differences were applied, individually and in combination, to five distinct, published, cancer biology-related cDNA microarray data sets. Leave-one-out cross-validation (LOOCV) classification error was employed as the quantitative end-point for assessing the effectiveness of a normalization method. In particular, a known classifier, k-nearest neighbor (k-NN), was estimated from data normalized using a given technique, and the LOOCV error rate of the ensuing model was computed. We found that k-NN classifiers are sensitive to dye biases in the data. Using NONRM and GMEDIAN as baseline methods, our results show that single-bias-removal techniques which remove either spatial-dependent dye bias (referred later as spatial effect) or intensity-dependent dye bias (referred later as intensity effect) moderately reduce LOOCV classification errors; whereas double-bias-removal techniques which remove both spatial- and intensity effect reduce LOOCV classification errors even further. Of the 41 different strategies examined, three two-step processes, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, all of which removed intensity effect globally and spatial effect locally, appear to reduce LOOCV classification errors most consistently and effectively across all data sets. We also found that the investigated scale normalization methods do not reduce LOOCV classification error. Using LOOCV error of k-NNs as the evaluation criterion, three double-bias-removal normalization strategies, IGLOESS-SLFILTERW7, ISTSPLINE-SLLOESS and IGLOESS-SLLOESS, outperform other strategies for removing spatial effect, intensity effect and scale differences from cDNA microarray data. The apparent sensitivity of k-NN LOOCV classification error to dye biases suggests that this criterion provides an informative measure for evaluating normalization methods. All the computational tools used in this study were implemented using the R language for statistical computing and graphics.
Deairing Techniques for Double-Ended Centrifugal Total Artificial Heart Implantation.
Karimov, Jamshid H; Horvath, David J; Byram, Nicole; Sunagawa, Gengo; Grady, Patrick; Sinkewich, Martin; Moazami, Nader; Sale, Shiva; Golding, Leonard A R; Fukamachi, Kiyotaka
2017-06-01
The unique device architecture of the Cleveland Clinic continuous-flow total artificial heart (CFTAH) requires dedicated and specific air-removal techniques during device implantation in vivo. These procedures comprise special surgical techniques and intraoperative manipulations, as well as engineering design changes and optimizations to the device itself. The current study evaluated the optimal air-removal techniques during the Cleveland Clinic double-ended centrifugal CFTAH in vivo implants (n = 17). Techniques and pump design iterations consisted of developing a priming method for the device and the use of built-in deairing ports in the early cases (n = 5). In the remaining cases (n = 12), deairing ports were not used. Dedicated air-removal ports were not considered an essential design requirement, and such ports may represent an additional risk for pump thrombosis. Careful passive deairing was found to be an effective measure with a centrifugal pump of this design. In this report, the techniques and design changes that were made during this CFTAH development program to enable effective residual air removal and prevention of air embolism during in vivo device implantation are explained. © 2016 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Zazouli, Mohammad Ali; Kalankesh, Laleh R
2017-01-01
Disinfection by-products (DBPs) have heterogeneous structures which are suspected carcinogens as a result of reactions between NOMs (Natural Organic Matter) and oxidants/disinfectants such as chlorine. Because of variability in DBPs characteristics, eliminate completely from drinking water by single technique is impossible. The current article reviews removal of the precursors and DBPs by different membrane filtration methods such as Microfiltration (MF), Ultrafiltration (UF), Nanofiltration (NF) and Reverse Osmosis (RO) techniques. Also, we provide an overview of existing and potentially Membrane filtration techniques, highlight their strengths and drawbacks. MF membranes are a suitable alternative to remove suspended solids and colloidal materials. However, NOMs fractions are effectively removed by negatively charged UF membrane. RO can remove both organic and inorganic DBPs and precursors simultaneously. NF can be used to remove compounds from macromolecular size to multivalent ions.
Dall'Agnol, Cristina; Hartmann, Mateus Silveira Martins; Barletta, Fernando Branco
2008-01-01
This study evaluated the efficiency of different techniques for removal of filling material from root canals, using computed tomography (CT). Sixty mesial roots from extracted human mandibular molars were used. Root canals were filled and, after 6 months, the teeth were randomly assigned to 3 groups, according to the root-filling removal technique: Group A - hand instrumentation with K-type files; Group B - reciprocating instrumentation with engine-driven K-type files; and Group C rotary instrumentation with engine-driven ProTaper system. CT scans were used to assess the volume of filling material inside the root canals before and after the removal procedure. In both moments, the area of filling material was outlined by an experienced radiologist and the volume of filling material was automatically calculated by the CT software program. Based on the volume of initial and residual filling material of each specimen, the percentage of filling material removed from the root canals by the different techniques was calculated. Data were analyzed statistically by ANOVA and chi-square test for linear trend (?=0.05). No statistically significant difference (p=0.36) was found among the groups regarding the percent means of removed filling material. The analysis of the association between the percentage of filling material removal (high or low) and the proposed techniques by chi-square test showed statistically significant difference (p=0.015), as most cases in group B (reciprocating technique) presented less than 50% of filling material removed (low percent removal). In conclusion, none of the techniques evaluated in this study was effective in providing complete removal of filling material from the root canals.
Alessandrini, Massimiliano; Battista, Fabrizio; Panighel, Annarita; Flamini, Riccardo; Tomasi, Diego
2018-03-01
Early leaf removal at pre-bloom is an innovative viticultural practice for regulating yield components and improving grape quality. The effects of this technique on vine performance, grape composition and wine sensory profile of Semillon variety were assessed. Pre-bloom leaf removal enhanced canopy porosity, total soluble solids in musts and reduced cluster compactness. This practice had a strong effect on glycoside aroma precursors, in particular by increasing glycoside terpenols and norisoprenoids. Metabolites of linalool were the most responsive to leaf removal. Wine produced from defoliated vines was preferred in tasting trials for its more intense fruity notes and mouthfeel attributes. Pre-bloom leaf removal is a powerful technique for modifying canopy microclimate, vine yield, grape composition and wine quality. The increase of glycoside aroma compounds in treated grapes has potential positive effect in improving the sensory profile of the resulting wines. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.
Wang, Zhenjun; Huang, Jiehao
2018-04-01
The phenomenon of water sensitivity often occurs in the oil reservoir core during the process of crude oil production, which seriously affects the efficiency of oil extraction. In recent years, near-well ultrasonic processing technology attaches more attention due to its safety and energy efficient. In this paper, the comparison of removing core water sensitivity by ultrasonic wave, chemical injection and ultrasound-chemical combination technique are investigated through experiments. Results show that: lower ultrasonic frequency and higher power can improve the efficiency of core water sensitivity removal; the effects of removing core water sensitivity under ultrasonic treatment get better with increase of core initial permeability; the effect of removing core water sensitivity using ultrasonic treatment won't get better over time. Ultrasonic treatment time should be controlled in a reasonable range; the effect of removing core water sensitivity using chemical agent alone is slightly better than that using ultrasonic treatment, however, chemical injection could be replaced by ultrasonic treatment for removing core water sensitivity from the viewpoint of oil reservoir protection and the sustainable development of oil field; ultrasound-chemical combination technique has the best effect for water sensitivity removal than using ultrasonic treatment or chemical injection alone. Copyright © 2017 Elsevier B.V. All rights reserved.
Malden, N J; Maidment, Y G
2002-08-24
Lingual nerve damage subsequent to lower wisdom tooth removal affects a small number of patients, sometimes producing permanent sensory loss or impairment. A number of surgical techniques have been described which are associated with low incidences of this distressing post-operative complication. When a technique is adopted by an individual clinician then a personal audit may be prudent to establish how effective it is in relation to established nerve injury rates. This audit looks at a technique involving the minimal interference of lingual soft tissues during lower wisdom tooth removal in a high street practice situation for patients having mild to moderate impacted wisdom teeth removed under local anaesthetic. It was concluded that the technique employed was associated with a low incidence of lingual nerve trauma, comparable with that reported elsewhere.
Initial experience using the rigid forceps technique to remove wall-embedded IVC filters.
Avery, Allan; Stephens, Maximilian; Redmond, Kendal; Harper, John
2015-06-01
Severely tilted and embedded inferior vena cava (IVC) filters remain the most challenging IVC filters to remove. Heavy endothelialisation over the filter hook can prevent engagement with standard snare and cone recovery techniques. The rigid forceps technique offers a way to dissect the endothelial cap and reliably retrieve severely tilted and embedded filters. By developing this technique, failed IVC retrieval rates can be significantly reduced and the optimum safety profile offered by temporary filters can be achieved. We present our initial experience with the rigid forceps technique described by Stavropoulos et al. for removing wall-embedded IVC filters. We retrospectively reviewed the medical imaging and patient records of all patients who underwent a rigid forceps filter removal over a 22-month period across two tertiary referral institutions. The rigid forceps technique had a success rate of 85% (11/13) for IVC filter removals. All filters in the series showed evidence of filter tilt and embedding of the filter hook into the IVC wall. Average filter tilt from the Z-axis was 19 degrees (range 8-56). Filters observed in the case study were either Bard G2X (n = 6) or Cook Celect (n = 7). Average filter dwell time was 421 days (range 47-1053). There were no major complications observed. The rigid forceps technique can be readily emulated and is a safe and effective technique to remove severely tilted and embedded IVC filters. The development of this technique across both institutions has increased the successful filter removal rate, with perceived benefits to the safety profile of our IVC filter programme. © 2015 The Royal Australian and New Zealand College of Radiologists.
[Endoscopy-assisted sialolithectomy for the calculus of the Stensen's duct].
Ye, Xin; Xie, Xiaoyan; Liu, Denggao; Zhang, Lei; Zhang, Zuyan; Yu, Guangyan
2014-11-01
To investigate the clinical effects of endoscopy-assisted sialolithectomy for the calculus in the Stensen's duct. From August 2005 to July 2013, 67 consecutive patients with calculus (or foreign bodies) in the Stensen's duct underwent explorative and interventional endoscopy in our hospital. The stones (or foreign bodies) were removed by endoscopy-assisted technique. After operation, the patients were followed-up periodically, and treatment effects were analyzed. Among the 67 patients, the stones (or foreign bodies) were completely removed in 58 cases, and almost completely removed in 3 cases, with a success rate of 87% (58/67). Among the 61 stone-removed cases, treatment options included direct removal with aid of basket or forceps (24 cases), basket entrapment and opening-up of the ostium (21 cases), basket entrapment and mucosal incision near the ostium (8 cases), open removal via buccal incision (2 cases) and open removal via pre-auricular flap (6 cases). During the 6-90 months' follow-up of the 61 cases, 48 cases were asymptomatic, 7 had mild symptoms, 3 developed ductal obturation, 1 had numbness in the parotid region, and the remaining 2 were missed. Endoscopy-assisted sialolithectomy is a safe and effective gland-preservation technique for the patients with parotid gland calculus.
A technique to remove the tensile instability in weakly compressible SPH
NASA Astrophysics Data System (ADS)
Xu, Xiaoyang; Yu, Peng
2018-01-01
When smoothed particle hydrodynamics (SPH) is directly applied for the numerical simulations of transient viscoelastic free surface flows, a numerical problem called tensile instability arises. In this paper, we develop an optimized particle shifting technique to remove the tensile instability in SPH. The basic equations governing free surface flow of an Oldroyd-B fluid are considered, and approximated by an improved SPH scheme. This includes the implementations of the correction of kernel gradient and the introduction of Rusanov flux into the continuity equation. To verify the effectiveness of the optimized particle shifting technique in removing the tensile instability, the impacting drop, the injection molding of a C-shaped cavity, and the extrudate swell, are conducted. The numerical results obtained are compared with those simulated by other numerical methods. A comparison among different numerical techniques (e.g., the artificial stress) to remove the tensile instability is further performed. All numerical results agree well with the available data.
Singh, Harpreet; Sharma, Rohit; Gupta, Sachin; Singh, Narinderjit; Singh, Simarpreet
2015-01-01
The advent of locking plates has brought new problems in implant removal. Difficulty in removing screws from a locking plate is well-known. These difficulties include cold welding between the screw head and locking screw hole, stripping of the recess of the screw head for the screwdriver, and cross-threading between threads in the screw head and screw hole. However, there are cases in which removal is difficult. We describe a new technique for removing a round headed, jammed locking screws from a locking plate. 55 years old male patient received a locking distal tibial plate along with distal fibular plate 3years back from UAE. Now patient came with complaint of non-healing ulcer over medial aspect of lower 1/3rd of right leg from past 1 year. Non operative management did not improve the symptoms. The patient consented to implant removal, with the express understanding that implant removal might be impossible because already one failed attempt had been performed at some other hospital six months back. We then decided to proceed with the new technique. The rest of the proximal screws were removed using a technique not previously described. We used stainless steel metal cutting blades that are used to cut door locks or pad locks to cut the remaining stripped headed screws. This technique is very quick, easy to perform and inexpensive because the metal cutting blades which are used to cut the screws are very cheap. Yet it is very effective technique to remove the stripped headed or jammed locking screws. It is also very less destructive because of very less heat production during the procedure there is no problem of thermal necrosis to the bone or the surrounding soft tissue.
Tissue artifact removal from respiratory signals based on empirical mode decomposition.
Liu, Shaopeng; Gao, Robert X; John, Dinesh; Staudenmayer, John; Freedson, Patty
2013-05-01
On-line measurement of respiration plays an important role in monitoring human physical activities. Such measurement commonly employs sensing belts secured around the rib cage and abdomen of the test object. Affected by the movement of body tissues, respiratory signals typically have a low signal-to-noise ratio. Removing tissue artifacts therefore is critical to ensuring effective respiration analysis. This paper presents a signal decomposition technique for tissue artifact removal from respiratory signals, based on the empirical mode decomposition (EMD). An algorithm based on the mutual information and power criteria was devised to automatically select appropriate intrinsic mode functions for tissue artifact removal and respiratory signal reconstruction. Performance of the EMD-algorithm was evaluated through simulations and real-life experiments (N = 105). Comparison with low-pass filtering that has been conventionally applied confirmed the effectiveness of the technique in tissue artifacts removal.
Active silicone oil removal with a modified vacuum syringe.
Bajaire, Boris J; Oudovitchenko, Elena; Salguero, Andrés E; Paipilla, Diego F
2012-01-01
At present, the number of clinical indications for the use of silicone oil (SO) has increased in intraocular surgery because of the advent of new techniques in vitreoretinal surgery, availability of better quality oils, and greater experience in its use. Consequently, the number of procedures for SO removal has increased, and support technologies for these procedures are always a concern. A simple active technique for SO removal based on a 5-mL standard syringe with an 18G cannula was developed. The oil is suctioned into the syringe by the pulling effect of a spring assembled along the axis of the piston. No abrupt change in the intraocular pressure is produced because of the oil viscosity and the reduced diameter of the cannula. A technique for SO removal that has been used successfully during the past 7 years is presented in this article. During the 7-year period, 234 SO removals were performed without any complication or device failure. Using the present method, the average time for SO removal was 4 minutes. The average extraction time with the technique is 4 minutes, which is in the range of other active techniques, and it is faster than passive methods that are performed between 8 and 9 minutes. The technique is in line with the advantages of more elaborated active methods without using complex technology. It is considered to be highly successful and easy to implement.
A Comparison of Three Different Thick Epinucleus Removal Techniques in Cataract Surgery.
Hwang, Ho Sik; Lim, Byung-Su; Kim, Man Soo; Kim, Eun Chul
2017-01-01
To compare the outcomes of cataract surgery performed with three different types of the epinucleus removal techniques (safe boat, infusion/aspiration (I/A) cannulas, and phacoemulsification tip). Ninety eyes with thick adhesive epinuclei were randomly subdivided into three groups according to epinucleus removal technique: epinucleus floating (safe boat) technique, 30 patients; I/A tip, 30 patients; and phaco tip, 30 patients. Intraoperative measurements included ultrasound time (UST), mean cumulative dissipated ultrasound energy (CDE), and balanced salt solution (BSS) use. Clinical measurements were made preoperatively, and at one day, one month and two months postoperatively, including the best corrected visual acuity (BCVA), the central corneal thickness (CCT), and the endothelial cell count (ECC). Intraoperative measurements showed significantly less UST, CDE, and BSS use in the safe boat group than in the phaco tip groups (p < 0.05). The percentage of endothelial cell loss in the safe boat group was significantly lower than that in the phaco tip groups at two months post-cataract surgery (p < 0.05). The safe boat technique is a safer and more effective epinucleus removal technique than phaco tip techniques in cases with thick epinucleus.
Techniques of Celloidin Removal From Temporal Bone Sections
O’Malley, Jennifer T.; Burgess, Barbara J.; Jones, Diane D.; Adams, Joe C.; Merchant, Saumil N.
2009-01-01
Objectives We sought to determine whether the technique of celloidin removal influences the results of immunostaining in celloidin-embedded cochleae. Methods We compared four protocols of celloidin removal, including those using clove oil, acetone, ether-alcohol, and methanol saturated with sodium hydroxide. By optimally fixing our tissue (perfused mice), and keeping constant the fixative type (formalin plus acetic acid), fixation time (25 hours), and decalcification time (ethylenediaminetetraacetic acid for 7 days), we determined whether the technique of celloidin removal influenced the immunostaining results. Six antibodies were used with each removal method: prostaglandin D synthase, sodium, potassium adenosine triphosphatase (Na+,K+-ATPase), aquaporin 1, connective tissue growth factor, tubulin, and 200 kd neurofilament. Results Clove oil, acetone, and ether-alcohol resulted in incomplete removal of the celloidin, thereby negatively affecting the results of immunostaining. The methanol–sodium hydroxide method was effective in completely removing the celloidin; it produced the cleanest and most reproducible immunostaining for all six antibodies. Conclusions Freshly prepared methanol saturated with sodium hydroxide and diluted 1:2 with methanol was the best solvent for removing celloidin from mouse temporal bone sections, resulting in consistent and reproducible immunostaining with the six antibodies tested. PMID:19663375
Improving clinical outcomes and patient experience through the use of desloughing.
Grothier, Lorraine
2015-09-01
This article focuses on and aims to clarify the role of desloughing as a priority in modern-day wound care. Ambiguity around identification and slough removal has long been a clinical challenge. Effective removal of slough involves the elimination of dead and devitalised tissue as quickly and safely as possible, to enable the wound to return to a healthy state that supports healing. Desloughing is usually associated with typically conservative techniques compared with those used to debride necrotic tissue. More specific and timely targeted action to recognise and remove slough safely will significantly improve the clinical outcomes for patients as well as influence the effective use of scarce resources. The illustrative format of this article will facilitate how clinicians can become familiar with the different types of slough and the appropriate removal techniques.
Microplate technique for determining accumulation of metals by algae
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hassett, J.M.; Jennett, J.C.; Smith, J.E.
1981-05-01
A microplate technique was developed to determine the conditions under which pure cultures of algae removed heavy metals from aqueous solutions. Variables investigated included algal species and strain, culture age (11 and 44 days), metal (mercury, lead, cadmium, and zinc), pH, effects of different buffer solutions, and time of exposure. Plastic, U-bottomed microtiter plates were used in conjunction with heavy metal radionuclides to determine concentration factors for metal-alga combinations. The technique developed was rapid, statistically reliable, and economical of materials and cells. All species of algae studied removed mercury from solution. Green algae proved better at accumulating cadmium than didmore » blue-green algae. No alga studied removed zinc, perhaps because cells were maintained in the dark during the labeling period. Chlamydomonas sp. proved superior in ability to remove lead from solution.« less
Lorenzo, Rosa A.; Carro, Antonia M.; Alvarez-Lorenzo, Carmen; Concheiro, Angel
2011-01-01
Template removal is a critical step in the preparation of most molecularly imprinted polymers (MIPs). The polymer network itself and the affinity of the imprinted cavities for the template make its removal hard. If there are remaining template molecules in the MIPs, less cavities will be available for rebinding, which decreases efficiency. Furthermore, if template bleeding occurs during analytical applications, errors will arise. Despite the relevance to the MIPs performance, template removal has received scarce attention and is currently the least cost-effective step of the MIP development. Attempts to reach complete template removal may involve the use of too drastic conditions in conventional extraction techniques, resulting in the damage or the collapse of the imprinted cavities. Advances in the extraction techniques in the last decade may provide optimized tools. The aim of this review is to analyze the available data on the efficiency of diverse extraction techniques for template removal, paying attention not only to the removal yield but also to MIPs performance. Such an analysis is expected to be useful for opening a way to rational approaches for template removal (minimizing the costs of solvents and time) instead of the current trial-and-error methods. PMID:21845081
Lorenzo, Rosa A; Carro, Antonia M; Alvarez-Lorenzo, Carmen; Concheiro, Angel
2011-01-01
Template removal is a critical step in the preparation of most molecularly imprinted polymers (MIPs). The polymer network itself and the affinity of the imprinted cavities for the template make its removal hard. If there are remaining template molecules in the MIPs, less cavities will be available for rebinding, which decreases efficiency. Furthermore, if template bleeding occurs during analytical applications, errors will arise. Despite the relevance to the MIPs performance, template removal has received scarce attention and is currently the least cost-effective step of the MIP development. Attempts to reach complete template removal may involve the use of too drastic conditions in conventional extraction techniques, resulting in the damage or the collapse of the imprinted cavities. Advances in the extraction techniques in the last decade may provide optimized tools. The aim of this review is to analyze the available data on the efficiency of diverse extraction techniques for template removal, paying attention not only to the removal yield but also to MIPs performance. Such an analysis is expected to be useful for opening a way to rational approaches for template removal (minimizing the costs of solvents and time) instead of the current trial-and-error methods.
Image processing on the image with pixel noise bits removed
NASA Astrophysics Data System (ADS)
Chuang, Keh-Shih; Wu, Christine
1992-06-01
Our previous studies used statistical methods to assess the noise level in digital images of various radiological modalities. We separated the pixel data into signal bits and noise bits and demonstrated visually that the removal of the noise bits does not affect the image quality. In this paper we apply image enhancement techniques on noise-bits-removed images and demonstrate that the removal of noise bits has no effect on the image property. The image processing techniques used are gray-level look up table transformation, Sobel edge detector, and 3-D surface display. Preliminary results show no noticeable difference between original image and noise bits removed image using look up table operation and Sobel edge enhancement. There is a slight enhancement of the slicing artifact in the 3-D surface display of the noise bits removed image.
Single-band mucosectomy for granular cell tumor of the esophagus: safe and easy technique.
Battaglia, G; Rampado, S; Bocus, P; Guido, E; Portale, G; Ancona, E
2006-08-01
Mucosectomy involves resection of a digestive wall fragment that frequently removes a part or even all of the submucosal mass. The single-band mucosectomy technique was used to remove a granular cell tumor (GCT) of the esophagus. Only 3% of GCTs, which are relatively uncommon neoplasms, arise in the esophagus. Ultrasonography has allowed for more frequent recognition and better definition of this disease. Until recently, surgical resection of the esophagus has been the only treatment alternative to endoscopic surveillance. Endoscopic techniques such as mucosal resection (EMR), laser, and argon plasma have been proposed as safe and effective alternatives to surgery. However, to date, only a few reports of these endoscopic techniques have been published. This study aimed to evaluate the safety and feasibility of single-band mucosectomy for removing a GCT of the esophagus. Six patients (1 man and 5 women; mean age, 45 years) with a GCT were studied between January 2000 and May 2004. They underwent EMR after endoscopic ultrasonography. The EMR was performed with a diathermic loop after injection of saline solution into the esophageal wall. Only one session was necessary for removal of the tumor from all 6 patients, and no complication was observed. During a mean clinical endoscopic follow-up period of 36 months, no recurrences, scars, or stenoses were observed. These findings show EMR to be a safe and effective technique that allows complete removal of GCTs. Furthermore, this technique provides tissue for a definitive pathologic diagnosis, which laser and argon plasma do not provide. We recommend EMR as the treatment of choice for GCTs after an accurate ultrasonographic evaluation.
Shannon Claeson; B. Coffin
2015-01-01
Dam removal is an increasingly practised river restoration technique, and ecological responses vary with watershed, dam and reservoir properties, and removal strategies. Moderate-sized dams, like Hemlock Dam (7.9m tall and 56m wide), are large enough that removal effects could be significant, but small enough that mitigation may be possible through a modified dam...
NASA Astrophysics Data System (ADS)
Passeport, Elodie; Vidon, Philippe; Forshay, Kenneth J.; Harris, Lora; Kaushal, Sujay S.; Kellogg, Dorothy Q.; Lazar, Julia; Mayer, Paul; Stander, Emilie K.
2013-02-01
Excess nitrogen (N) in freshwater systems, estuaries, and coastal areas has well-documented deleterious effects on ecosystems. Ecological engineering practices (EEPs) may be effective at decreasing nonpoint source N leaching to surface and groundwater. However, few studies have synthesized current knowledge about the functioning principles, performance, and cost of common EEPs used to mitigate N pollution at the watershed scale. Our review describes seven EEPs known to decrease N to help watershed managers select the most effective techniques from among the following approaches: advanced-treatment septic systems, low-impact development (LID) structures, permeable reactive barriers, treatment wetlands, riparian buffers, artificial lakes and reservoirs, and stream restoration. Our results show a broad range of N-removal effectiveness but suggest that all techniques could be optimized for N removal by promoting and sustaining conditions conducive to biological transformations (e.g., denitrification). Generally, N-removal efficiency is particularly affected by hydraulic residence time, organic carbon availability, and establishment of anaerobic conditions. There remains a critical need for systematic empirical studies documenting N-removal efficiency among EEPs and potential environmental and economic tradeoffs associated with the widespread use of these techniques. Under current trajectories of N inputs, land use, and climate change, ecological engineering alone may be insufficient to manage N in many watersheds, suggesting that N-pollution source prevention remains a critical need. Improved understanding of N-removal effectiveness and modeling efforts will be critical in building decision support tools to help guide the selection and application of best EEPs for N management.
Physiotherapy Secretion Removal Techniques in People With Spinal Cord Injury: A Systematic Review
Reid, W. Darlene; Brown, Jennifer A; Konnyu, Kristin J; Rurak, Jennifer M.E; Sakakibara, Brodie M
2010-01-01
Objective: To address whether secretion removal techniques increase airway clearance in people with chronic spinal cord injury (SCI). Data Sources and Study Selection: MEDLINE/PubMed, CINAHL, EMBASE, and PsycINFO were searched from inception to May 2009 for population keywords (spinal cord injury, paraplegia, tetraplegia, quadriplegia) paired with secretion removal–related interventions and outcomes. Inclusion criteria for articles were a research study, irrespective of design, that examined secretion removal in people with chronic SCI published in English. Review Methods: Two reviewers determined whether articles met the inclusion criteria, abstracted information, and performed a quality assessment using PEDro or Downs and Black criteria. Studies were then given a level of evidence based on a modified Sackett scale. Results: Of 2,416 abstracts and titles retrieved, 24 met the inclusion criteria. Subjects were young (mean, 31 years) and 84% were male. Most evidence was level 4 or 5 and only 2 studies were randomized controlled trials. Three reports described outcomes for secretion removal techniques in addition to cough, whereas most articles examined the immediate effects of various components of cough. Studies examining insufflation combined with manual assisted cough provided the most consistent, high-level evidence. Compelling recent evidence supports the use of respiratory muscle training or electrical stimulation of the expiratory muscles to facilitate airway clearance in people with SCI. Conclusion: Evidence supporting the use of secretion removal techniques in SCI, while positive, is limited and mostly of low level. Treatments that increase respiratory muscle force show promise as effective airway clearance techniques. PMID:21061895
The effect of four different irrigation systems in the removal of a root canal sealer.
Grischke, J; Müller-Heine, A; Hülsmann, M
2014-09-01
The aim of this study was to compare the efficiency of sonic, ultrasonic, and hydrodynamic devices in the removal of a root canal sealer from the surface and from simulated irregularities of root canals. Fifty-three root canals with two standardized grooves in the apical and coronal parts of longitudinally split roots were covered with AH Plus root canal sealer. Compared were the effects of (control) syringe irrigation, (1) CanalBrush, (2) passive ultrasonic irrigation, (3) EndoActivator, and (4) RinsEndo on the removal of the sealer. The specimens were divided into four groups (N = 12) and one control group (N = 5) via randomization. The amount of remaining sealer in the root canal irregularities was evaluated under a microscope using a 4-grade scoring system, whereas the remaining sealer on the root canal surface was evaluated with a 7-grade scoring system. Passive ultrasonic irrigation is more effective than the other tested irrigation systems or syringe irrigation in removing sealer from root canal walls (p < 0.01). None of the techniques had a significant effect on cleaning the lateral grooves. Within the limitations of this study protocol ultrasonic irrigation shows a superior effect on sealer removal from the root canal surface during endodontic retreatment. Cleaning of lateral grooves seems not to be possible with one of the techniques investigated. Incomplete removal of root canal sealer during re-treatment may cause treatment failure. Passive Ultrasonic irrigation seems to be the most effective system to remove sealer from a root canal.
The MOF+ Technique: A Significant Synergic Effect Enables High Performance Chromate Removal.
Luo, Ming Biao; Xiong, Yang Yang; Wu, Hui Qiong; Feng, Xue Feng; Li, Jian Qiang; Luo, Feng
2017-12-18
A significant synergic effect between a metal-organic framework (MOF) and Fe 2 SO 4 , the so-called MOF + technique, is exploited for the first time to remove toxic chromate from aqueous solutions. The results show that relative to the pristine MOF samples (no detectable chromate removal), the MOF + method enables super performance, giving a 796 Cr mg g -1 adsorption capacity. The value is almost eight-fold higher than the best value of established MOF adsorbents, and the highest value of all reported porous adsorbents for such use. The adsorption mechanism, unlike the anion-exchange process that dominates chromate removal in all other MOF adsorbents, as unveiled by X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM), and transmission electron microscopy (TEM), is due to the surface formation of Fe 0.75 Cr 0.25 (OH) 3 nanospheres on the MOF samples. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
A novel background field removal method for MRI using projection onto dipole fields (PDF).
Liu, Tian; Khalidov, Ildar; de Rochefort, Ludovic; Spincemaille, Pascal; Liu, Jing; Tsiouris, A John; Wang, Yi
2011-11-01
For optimal image quality in susceptibility-weighted imaging and accurate quantification of susceptibility, it is necessary to isolate the local field generated by local magnetic sources (such as iron) from the background field that arises from imperfect shimming and variations in magnetic susceptibility of surrounding tissues (including air). Previous background removal techniques have limited effectiveness depending on the accuracy of model assumptions or information input. In this article, we report an observation that the magnetic field for a dipole outside a given region of interest (ROI) is approximately orthogonal to the magnetic field of a dipole inside the ROI. Accordingly, we propose a nonparametric background field removal technique based on projection onto dipole fields (PDF). In this PDF technique, the background field inside an ROI is decomposed into a field originating from dipoles outside the ROI using the projection theorem in Hilbert space. This novel PDF background removal technique was validated on a numerical simulation and a phantom experiment and was applied in human brain imaging, demonstrating substantial improvement in background field removal compared with the commonly used high-pass filtering method. Copyright © 2011 John Wiley & Sons, Ltd.
Optimized distortion correction technique for echo planar imaging.
Chen , N K; Wyrwicz, A M
2001-03-01
A new phase-shifted EPI pulse sequence is described that encodes EPI phase errors due to all off-resonance factors, including B(o) field inhomogeneity, eddy current effects, and gradient waveform imperfections. Combined with the previously proposed multichannel modulation postprocessing algorithm (Chen and Wyrwicz, MRM 1999;41:1206-1213), the encoded phase error information can be used to effectively remove geometric distortions in subsequent EPI scans. The proposed EPI distortion correction technique has been shown to be effective in removing distortions due to gradient waveform imperfections and phase gradient-induced eddy current effects. In addition, this new method retains advantages of the earlier method, such as simultaneous correction of different off-resonance factors without use of a complicated phase unwrapping procedure. The effectiveness of this technique is illustrated with EPI studies on phantoms and animal subjects. Implementation to different versions of EPI sequences is also described. Magn Reson Med 45:525-528, 2001. Copyright 2001 Wiley-Liss, Inc.
Coagulant plus ballast technique provides a rapid mitigation of cyanobacterial nuisance
de Magalhães, Leonardo; Miranda, Marcela; Mucci, Maíra; van Oosterhout, Frank; Huszar, Vera L. M.; Marinho, Marcelo M.; Lima, Eduardo R. A.; Lürling, Miquel
2017-01-01
Cyanobacteria blooms are a risk to environmental health and public safety due to the potent toxins certain cyanobacteria can produce. These nuisance organisms can be removed from water bodies by biomass flocculation and sedimentation. Here, we studied the efficacy of combinations of a low dose coagulant (poly-aluminium chloride—PAC—or chitosan) with different ballast compounds (red soil, bauxite, gravel, aluminium modified zeolite and lanthanum modified bentonite) to remove cyanobacterial biomass from water collected in Funil Reservoir (Brazil). We tested the effect of different cyanobacterial biomass concentrations on removal efficiency. We also examined if zeta potential was altered by treatments. Addition of low doses of PAC and chitosan (1–8 mg Al L-1) to the cyanobacterial suspensions caused flock formation, but did not settle the cyanobacteria. When those low dose coagulants were combined with ballast, effective settling in a dose-dependent way up to 99.7% removal of the flocks could be achieved without any effect on the zeta potential and thus without potential membrane damage. Removal efficacy was influenced by the cyanobacterial biomass and at higher biomass more ballast was needed to achieve good removal. The combined coagulant-ballast technique provides a promising alternative to algaecides in lakes, ponds and reservoirs. PMID:28598977
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, R.W.
1995-05-01
A feasibility/treatability study was performed to investigate the leaching potential of heavy metals (particularly lead) from soils at the Grafenw6hr Training Area (GTA) in Germany. The study included an evaluation of the effectiveness of chelant extraction to remediate the heavy-metal-contarninated soils. Batch shaker tests indicated that ethylenediaminetetraacetic acid (EDTA) (0.01M) was more effective than citric acid (0.01M) at removing cadmium, copper, lead, and zinc. EDTA and citric acid were equally effective in mobilizing chromium and barium from the soil. The batch shaker technique with chelant extraction offers promise as a remediation technique for heavy-metal-contaninated soil at the GTA. Columnar floodingmore » tests conducted as part of the study revealed that deionized water was the least effective leaching solution for mobilization of the heavy metals; the maximum solubilization obtained was 3.72% for cadmium. EDTA (0.05M) achieved the greatest removal of lead (average removal of 17.6%). The difficulty of extraction using deionized water indicates that all of the heavy metals are very tightly bound to the soil; therefore, they are very stable in the GTA soils and do not pose a serious threat to the groundwater system. Columnar flooding probably does not represent a viable remediation technique for in-situ cleanup of heavy-metal-contaminated soils at the GTA.« less
Comparison of various techniques for calibration of AIS data
NASA Technical Reports Server (NTRS)
Roberts, D. A.; Yamaguchi, Y.; Lyon, R. J. P.
1986-01-01
The Airborne Imaging Spectrometer (AIS) samples a region which is strongly influenced by decreasing solar irradiance at longer wavelengths and strong atmospheric absorptions. Four techniques, the Log Residual, the Least Upper Bound Residual, the Flat Field Correction and calibration using field reflectance measurements were investigated as a means for removing these two features. Of the four techniques field reflectance calibration proved to be superior in terms of noise and normalization. Of the other three techniques, the Log Residual was superior when applied to areas which did not contain one dominant cover type. In heavily vegetated areas, the Log Residual proved to be ineffective. After removing anomalously bright data values, the Least Upper Bound Residual proved to be almost as effective as the Log Residual in sparsely vegetated areas and much more effective in heavily vegetated areas. Of all the techniques, the Flat Field Correction was the noisest.
Shabzendedar, Mahbobeh; Moosavi, Horieh; Talbi, Maryam; Sharifi, Marjan
2011-11-01
The goal of the study was to evaluate the effect of caries removal by three various methods on the permeability of class II composite resin restorations in primary molar teeth. Forty-five recently extracted primary molars were randomly assigned to three groups for three different methods of caries removal; group 1-mechanical, group 2-caries detector dye, and group 3-Carisolv (n = 15). After that, class II cavities in all groups were restored with the adhesive (Opti Bond Solo Plus) that was applied according to the manufacturer's instruction and a posterior composite (Herculite XRV), which was used incrementally. After 24 hours the samples were thermocycled in water for 500 cycles between 5 and 55°C with a dwell time of 30 sec. Permeability was assessed by the fluid filtration method. The data were analyzed using the ANOVA test while study groups were compared with Tukey test for statistically significant differences at a 5% significance level. The evaluation of tested groups indicated that the highest (0.80) and least (0.37) mean of permeability was observed in group 2 and 3 respectively. Significant difference was revealed among the tested groups (p = 0.045). The comparison of Carisolv and caries detector dye groups indicated a statistically significant difference (p = 0.037). There was not any significant difference between Carisolv or caries dye in the conventional group. Using the chemomechanical and staining methods for caries removal had no more detrimental effect on permeability than the conventional technique. However, caries detection dye for caries removal could be more harmful than chemomechanical method. None of the current caries-excavation techniques could eliminate permeability in class II composite resin restorations. Furthermore, staining methods do not have an adverse effect on sealing ability in comparison to the conventional technique.
NASA Astrophysics Data System (ADS)
Sakurai, Yoshinori; Ono, Koji; Miyatake, Shin-ichi; Maruhashi, Akira
2006-03-01
Boron neutron capture therapy (BNCT) without craniotomy for malignant brain tumours was started using an epi-thermal neutron beam at the Kyoto University Reactor in June 2002. We have tried some techniques to overcome the treatable-depth limit in BNCT. One of the effective techniques is void formation utilizing a tumour-removed cavity. The tumorous part is removed by craniotomy about 1 week before a BNCT treatment in our protocol. Just before the BNCT irradiation, the cerebro-spinal fluid (CSF) in the tumour-removed cavity is drained out, air is infused to the cavity and then the void is made. This void improves the neutron penetration, and the thermal neutron flux at depth increases. The phantom experiments and survey simulations modelling the CSF drainage and air infusion of the tumour-removed cavity were performed for the size and shape of the void. The advantage of the CSF drainage and air infusion is confirmed for the improvement in the depth-dose distribution. From the parametric surveys, it was confirmed that the cavity volume had good correlation with the improvement effect, and the larger effect was expected as the cavity volume was larger.
Sakurai, Yoshinori; Ono, Koji; Miyatake, Shin-Ichi; Maruhashi, Akira
2006-03-07
Boron neutron capture therapy (BNCT) without craniotomy for malignant brain tumours was started using an epi-thermal neutron beam at the Kyoto University Reactor in June 2002. We have tried some techniques to overcome the treatable-depth limit in BNCT. One of the effective techniques is void formation utilizing a tumour-removed cavity. The tumorous part is removed by craniotomy about 1 week before a BNCT treatment in our protocol. Just before the BNCT irradiation, the cerebro-spinal fluid (CSF) in the tumour-removed cavity is drained out, air is infused to the cavity and then the void is made. This void improves the neutron penetration, and the thermal neutron flux at depth increases. The phantom experiments and survey simulations modelling the CSF drainage and air infusion of the tumour-removed cavity were performed for the size and shape of the void. The advantage of the CSF drainage and air infusion is confirmed for the improvement in the depth-dose distribution. From the parametric surveys, it was confirmed that the cavity volume had good correlation with the improvement effect, and the larger effect was expected as the cavity volume was larger.
Effective removal of equine arteritis virus from stallion semen.
Morrell, J M; Geraghty, R M
2006-05-01
A method of removing equine arteritis virus (EAV) from equine semen used for artificial insemination is urgently needed. Recent medical studies suggest that a double semen processing technique of density gradient centrifugation followed by a 'swim-up' can provide virus-free sperm preparations for assisted reproduction. To investigate the use of the double semen processing technique to obtain virus-free sperm preparations from stallion semen containing EAV. Aliquots of an ejaculate from an uninfected stallion were spiked with virus and processed by the double processing technique. The sperm preparations were tested by PCR for the presence of EAV. The procedure was repeated using an ejaculate from a known shedding stallion, testing processed and unprocessed aliquots by PCR and virus isolation. Virus-free sperm preparations were obtained using the double sperm processing technique. The 'swim-up' step is apparently required to ensure complete virus removal. The double semen processing technique is potentially a useful and simple tool for the removal of EAV from the semen of shedding stallions. The inclusion of density gradient centrifugation and 'swim-up' in protocols for the processing of semen for artificial insemination could help prevent the transmission of viral diseases carried in semen, such as EAV.
Using GC-FID to Quantify the Removal of 4-sec-Butylphenol from NGS Solvent by NaOH
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sloop, Jr., Frederick V.; Moyer, Bruce A.
2014-12-01
A caustic wash of the solvent used in the Next-Generation Caustic-Side Solvent Extraction (NG-CSSX) process was found to remove the modifier breakdown product 4-sec-butylphenol (SBP) with varying efficiency depending on the aqueous NaOH concentration. Recent efforts at ORNL have aimed at characterizing the flowsheet chemistry and reducing the technical uncertainties of the NG-CSSX process. One technical uncertainty has been the efficacy of caustic washing of the solvent for the removal of lipophilic anions, in particular, the efficient removal of SBP, an important degradation product of the solvent modifier, Cs-7SB. In order to make this determination, it was necessary to developmore » a sensitive and reliable analytical technique for the detection and quantitation of SBP. This report recounts the development of a GC-FID-based (Gas Chromatography Flame Ionization Detection) technique for analyzing SBP and the utilization of the technique to subsequently confirm the ability of the caustic wash to efficiently remove SBP from the Next Generation Solvent (NGS) used in NG-CSSX. In particular, the developed technique was used to monitor the amount of SBP removed from a simple solvent and the full NGS by contact with sodium hydroxide wash solutions over a range of concentrations. The results show that caustic washing removes SBP with effectively the same efficiency as it did in the original Caustic-Side Solvent Extraction (CSSX) process.« less
1992-04-14
is a minimally invasive endoscopic surgical procedure to remove the appendix. From December 1990 to February 1991, Tripler Army Medical Center...appendectomy appears to be a safe, cost-effective, minimally invasive surgical technique that in skilled hands may be used to remove most diseased appendices...requiring surgical intervention [1]. Management of this disease process has traditionally involved the surgical removal of the appendix through a right
Sim, K S; Teh, V; Tey, Y C; Kho, T K
2016-11-01
This paper introduces new development technique to improve the Scanning Electron Microscope (SEM) image quality and we name it as sub-blocking multiple peak histogram equalization (SUB-B-MPHE) with convolution operator. By using this new proposed technique, it shows that the new modified MPHE performs better than original MPHE. In addition, the sub-blocking method consists of convolution operator which can help to remove the blocking effect for SEM images after applying this new developed technique. Hence, by using the convolution operator, it effectively removes the blocking effect by properly distributing the suitable pixel value for the whole image. Overall, the SUB-B-MPHE with convolution outperforms the rest of methods. SCANNING 38:492-501, 2016. © 2015 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.
Are visual cue masking and removal techniques equivalent for studying perceptual skills in sport?
Mecheri, Sami; Gillet, Eric; Thouvarecq, Regis; Leroy, David
2011-01-01
The spatial-occlusion paradigm makes use of two techniques (masking and removing visual cues) to provide information about the anticipatory cues used by viewers. The visual scene resulting from the removal technique appears to be incongruous, but the assumed equivalence of these two techniques is spreading. The present study was designed to address this issue by combining eye-movement recording with the two types of occlusion (removal versus masking) in a tennis serve-return task. Response accuracy and decision onsets were analysed. The results indicated that subjects had longer reaction times under the removal condition, with an identical proportion of correct responses. Also, the removal technique caused the subjects to rely on atypical search patterns. Our findings suggest that, when the removal technique was used, viewers were unable to systematically count on stored memories to help them accomplish the interception task. The persistent failure to question some of the assumptions about the removal technique in applied visual research is highlighted, and suggestions for continued use of the masking technique are advanced.
Anteriorly placed tumors to the conus: removal by interradicular window.
Ciappetta, P; Taurone, S; Spoletini, M; Artico, M
2017-01-01
Tumors anteriorly situated to the medullary conus are rarely encountered and represent a true surgical challenge. We examined the literature on this topic, concluding that there are no previous reports on alternative surgical techniques different to the traditional one. We report two cases of intradural extramedullary tumor operated on by a technique performed through a window opened between the spinal roots, which allows an easy, effective and useful resection. We describe a new operative technique which ensures a complete removal of these tumors and discuss clinical implications in the light of the available literature on this topic.
[Survey on the contamination of microcystin-LR in water supply of Shanghai city].
Wu, He-yan; Zheng, Li-xing; Su, Jin; Shi, Wei
2005-03-01
To study the pollution level of microcystin-LR in water supply of Shanghai city and the removal efficacy for microcystin-LR through routine water treatment technique. High performance liquid chromatogram (HPLC) was applied to determine the concentration of microcystin-LR in source water, water samples after various water treatment procedures and tap water. The concentration of microcystin-LR varied with sampling seasons and sites and reached peak during summer and fall. The maximum of microcystin-LR was 2.38 microg/L in source water. Coagulation plus chlorine disinfection were found to be effective for the removal of microcystin-LR, while the remove rate through filtration was not significant. And it could also be detected in tap water as high as 1.27 microg/L. The source waters of Shanghai city were polluted by cyanobacteria toxins represented by microcystin-LR. The source water in suburb was more polluted. Routine water treatment techniques can not remove the toxins effectively.
A Novel AMARS Technique for Baseline Wander Removal Applied to Photoplethysmogram.
Timimi, Ammar A K; Ali, M A Mohd; Chellappan, K
2017-06-01
A new digital filter, AMARS (aligning minima of alternating random signal) has been derived using trigonometry to regulate signal pulsations inline. The pulses are randomly presented in continuous signals comprising frequency band lower than the signal's mean rate. Frequency selective filters are conventionally employed to reject frequencies undesired by specific applications. However, these conventional filters only reduce the effects of the rejected range producing a signal superimposed by some baseline wander (BW). In this work, filters of different ranges and techniques were independently configured to preprocess a photoplethysmogram, an optical biosignal of blood volume dynamics, producing wave shapes with several BWs. The AMARS application effectively removed the encountered BWs to assemble similarly aligned trends. The removal implementation was found repeatable in both ear and finger photoplethysmograms, emphasizing the importance of BW removal in biosignal processing in retaining its structural, functional and physiological properties. We also believe that AMARS may be relevant to other biological and continuous signals modulated by similar types of baseline volatility.
Removal of algal blooms from freshwater by the coagulation-magnetic separation method.
Liu, Dan; Wang, Peng; Wei, Guanran; Dong, Wenbo; Hui, Franck
2013-01-01
This research investigated the feasibility of changing waste into useful materials for water treatment and proposed a coagulation-magnetic separation technique. This technique was rapid and highly effective for clearing up harmful algal blooms in freshwater and mitigating lake eutrophication. A magnetic coagulant was synthesized by compounding acid-modified fly ash with magnetite (Fe(3)O(4)). Its removal effects on algal cells and dissolved organics in water were studied. After mixing, coagulation, and magnetic separation, the flocs obtained from the magnet surface were examined by SEM. Treated samples were withdrawn for the content determination of chlorophyll-a, turbidity, chemical oxygen demand (COD), total nitrogen, and total phosphorus. More than 99 % of algal cells were removed within 5 min after the addition of magnetic coagulant at optimal loadings (200 mg L(-1)). The removal efficiencies of COD, total nitrogen, and phosphorus were 93, 91, and 94 %, respectively. The mechanism of algal removal explored preliminarily showed that the magnetic coagulant played multiple roles in mesoporous adsorption, netting and bridging, as well as high magnetic responsiveness to a magnetic field. The magnetic-coagulation separation method can rapidly and effectively remove algae from water bodies and greatly mitigate eutrophication of freshwater using a new magnetic coagulant. The method has good performance, is low cost, can turn waste into something valuable, and provides reference and directions for future pilot and production scale-ups.
House, J W
1993-06-01
This article reviews the evolution of the author's stapedectomy technique from total footplate removal with single loop wire prosthesis and Gelfoam seal to small fenestra stapedectomy with platinum ribbon piston prosthesis and blood seal. The author concludes that the microdrill is effective, safe, and cost effective for performing this procedure. Since using this technique, the author has had no cases of sensorineural hearing loss and few complaints of dizziness or vertigo.
Liu, Yangxian; Wang, Qian
2014-10-21
In this article, a novel technique on removal of elemental mercury (Hg(0)) from flue gas by thermally activated ammonium persulfate ((NH4)(2)S(2)O(8)) has been developed for the first time. Some experiments were carried out in a bubble column reactor to evaluate the effects of process parameters on Hg(0) removal. The mechanism and kinetics of Hg(0) removal are also studied. The results show that the parameters, (NH4)(2)S(2)O(8) concentration, activation temperature and solution pH, have significant impacts on Hg(0) removal. The parameters, Hg(0), SO2 and NO concentration, only have small effects on Hg(0) removal. Hg(0) is removed by oxidations of (NH4)(2)S(2)O(8), sulfate and hydroxyl free radicals. When (NH4)(2)S(2)O(8) concentration is more than 0.1 mol/L and solution pH is lower than 9.71, Hg(0) removal by thermally activated (NH4)(2)S(2)O(8) meets a pseudo-first-order fast reaction with respect to Hg(0). However, when (NH4)(2)S(2)O(8) concentration is less than 0.1 mol/L or solution pH is higher than 9.71, the removal process meets a moderate speed reaction with respect to Hg(0). The above results indicate that this technique is a feasible method for emission control of Hg(0) from flue gas.
Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water
Hoang, Anh T.; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D.
2018-01-01
A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m2h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection. PMID:29671797
Water Reclamation Using a Ceramic Nanofiltration Membrane and Surface Flushing with Ozonated Water.
Fujioka, Takahiro; Hoang, Anh T; Okuda, Tetsuji; Takeuchi, Haruka; Tanaka, Hiroaki; Nghiem, Long D
2018-04-19
A new membrane fouling control technique using ozonated water flushing was evaluated for direct nanofiltration (NF) of secondary wastewater effluent using a ceramic NF membrane. Experiments were conducted at a permeate flux of 44 L/m²h to evaluate the ozonated water flushing technique for fouling mitigation. Surface flushing with clean water did not effectively remove foulants from the NF membrane. In contrast, surface flushing with ozonated water (4 mg/L dissolved ozone) could effectively remove most foulants to restore the membrane permeability. This surface flushing technique using ozonated water was able to limit the progression of fouling to 35% in transmembrane pressure increase over five filtration cycles. Results from this study also heighten the need for further development of ceramic NF membrane to ensure adequate removal of pharmaceuticals and personal care products (PPCPs) for water recycling applications. The ceramic NF membrane used in this study showed approximately 40% TOC rejection, and the rejection of PPCPs was generally low and highly variable. It is expected that the fouling mitigation technique developed here is even more important for ceramic NF membranes with smaller pore size and thus better PPCP rejection.
Coblation: improving outcomes for children following adenotonsillectomy.
Benninger, Michael; Walner, David
2007-01-01
Tonsillectomy and adenoidectomy, 2 of the most common childhood surgeries, are performed for a number of indications, the most common being airway obstruction caused by adenotonsillar hypertrophy. Other indications for tonsillectomy include recurrent pharyngotonsillitis, streptococcal carriage, recurrent peritonsillar abscess, halitosis, and presumed neoplasia. Although adenotonsillar surgery is a safe and effective technique for treating disease and obstruction, parents remain concerned about postoperative morbidity, for which the potential is much greater after tonsillectomy than adenoidectomy. Postoperative pain and hemorrhage are 2 unpleasant side effects that can prolong postoperative recovery. Surgeons use a variety of surgical techniques to remove the tonsils and adenoids. When compared with older techniques, such as cold steel dissection and monopolar electrocautery, a new technique named Coblation that uses lower temperatures than electrocautery to remove tonsil tissue and achieve hemostasis, has been shown to reduce pain and decrease postoperative narcotic use, leading to shorter recovery times and a quicker return to normal in children.
NASA Astrophysics Data System (ADS)
Dyar, M. Darby; Giguere, Stephen; Carey, CJ; Boucher, Thomas
2016-12-01
This project examines the causes, effects, and optimization of continuum removal in laser-induced breakdown spectroscopy (LIBS) to produce the best possible prediction accuracy of elemental composition in geological samples. We compare prediction accuracy resulting from several different techniques for baseline removal, including asymmetric least squares (ALS), adaptive iteratively reweighted penalized least squares (Air-PLS), fully automatic baseline correction (FABC), continuous wavelet transformation, median filtering, polynomial fitting, the iterative thresholding Dietrich method, convex hull/rubber band techniques, and a newly-developed technique for Custom baseline removal (BLR). We assess the predictive performance of these methods using partial least-squares analysis for 13 elements of geological interest, expressed as the weight percentages of SiO2, Al2O3, TiO2, FeO, MgO, CaO, Na2O, K2O, and the parts per million concentrations of Ni, Cr, Zn, Mn, and Co. We find that previously published methods for baseline subtraction generally produce equivalent prediction accuracies for major elements. When those pre-existing methods are used, automated optimization of their adjustable parameters is always necessary to wring the best predictive accuracy out of a data set; ideally, it should be done for each individual variable. The new technique of Custom BLR produces significant improvements in prediction accuracy over existing methods across varying geological data sets, instruments, and varying analytical conditions. These results also demonstrate the dual objectives of the continuum removal problem: removing a smooth underlying signal to fit individual peaks (univariate analysis) versus using feature selection to select only those channels that contribute to best prediction accuracy for multivariate analyses. Overall, the current practice of using generalized, one-method-fits-all-spectra baseline removal results in poorer predictive performance for all methods. The extra steps needed to optimize baseline removal for each predicted variable and empower multivariate techniques with the best possible input data for optimal prediction accuracy are shown to be well worth the slight increase in necessary computations and complexity.
Removal of 226Ra and 228Ra from TENORM sludge waste using surfactants solutions.
Attallah, M F; Hamed, Mostafa M; El Afifi, E M; Aly, H F
2015-01-01
The feasibility of using surfactants as extracting agent for the removal of radium species from TENORM sludge produced from petroleum industry is evaluated. In this investigation cationic and nonionic surfactants were used as extracting agents for the removal of radium radionuclides from the sludge waste. Two surfactants namely cetyltrimethylammonium bromide (CTAB) and Triton X-100 (TX100) were investigated as the extracting agents. Different parameters affecting the removal of both (226)Ra and (228)Ra by the two surfactants as well as their admixture were studied by the batch technique. These parameters include effect of shaking time, surfactants concentration and temperature as well as the effect of surfactants admixture. It was found that, higher solution temperature improves the removal efficiency of radium species. Combined extraction of nonionic and cationic surfactants produces synergistic effect in removal both (226)Ra and (228)Ra, where the removals reached 84% and 80% for (226)Ra and (228)Ra, respectively, were obtained using surfactants admixture. Copyright © 2014 Elsevier Ltd. All rights reserved.
Pakdel, Farzad; Hadizadeh, Homayoun; Pirmarzdashty, Niloofar; Kiavash, Victoria
2015-01-01
A 59-year-old patient developed acute proptosis, peri-orbital swelling and restriction of ocular movements 2 days after attempted scleral buckle removal. Initial clinical and orbital MRI findings were suggestive for orbital cellulitis and orbital abscess. Empiric intravenous antibiotics were not effective. Proton magnetic resonance spectroscopy (MRS) revealed a distinctive composition and helped rule out suppurative and neoplastic processes. The patient recovered soon after removing clear liquefied and tiny particles of the hydrogel buckle by an effective peristaltic technique.
An integrated anaerobic digestion and UV photocatalytic treatment of distillery wastewater.
Apollo, Seth; Onyango, Maurice S; Ochieng, Aoyi
2013-10-15
Anaerobic up-flow fixed bed reactor and annular photocatalytic reactor were used to study the efficiency of integrated anaerobic digestion (AD) and ultraviolet (UV) photodegradation of real distillery effluent and raw molasses wastewater (MWW). It was found that UV photodegradation as a stand-alone technique achieved colour removal of 54% and 69% for the distillery and MWW, respectively, with a COD reduction of <20% and a negligible BOD reduction. On the other hand, AD as a single treatment technique was found to be effective in COD and BOD reduction with efficiencies of above 75% and 85%, respectively, for both wastewater samples. However, the AD achieved low colour removal efficiency, with an increase in colour intensity of 13% recorded when treating MWW while a colour removal of 51% was achieved for the distillery effluent. The application of UV photodegradation as a pre-treatment method to the AD process reduced the COD removal and biogas production efficiency. However, an integration in which UV photodegradation was employed as a post-treatment to the AD process achieved high COD removal of above 85% for both wastewater samples, and colour removal of 88% for the distillery effluent. Thus, photodegradation can be employed as a post-treatment technique to an AD system treating distillery effluent for complete removal of the biorecalcitrant and colour imparting compounds. Copyright © 2013 Elsevier B.V. All rights reserved.
Defogging of road images using gain coefficient-based trilateral filter
NASA Astrophysics Data System (ADS)
Singh, Dilbag; Kumar, Vijay
2018-01-01
Poor weather conditions are responsible for most of the road accidents year in and year out. Poor weather conditions, such as fog, degrade the visibility of objects. Thus, it becomes difficult for drivers to identify the vehicles in a foggy environment. The dark channel prior (DCP)-based defogging techniques have been found to be an efficient way to remove fog from road images. However, it produces poor results when image objects are inherently similar to airlight and no shadow is cast on them. To eliminate this problem, a modified restoration model-based DCP is developed to remove the fog from road images. The transmission map is also refined by developing a gain coefficient-based trilateral filter. Thus, the proposed technique has an ability to remove fog from road images in an effective manner. The proposed technique is compared with seven well-known defogging techniques on two benchmark foggy images datasets and five real-time foggy images. The experimental results demonstrate that the proposed approach is able to remove the different types of fog from roadside images as well as significantly improve the image's visibility. It also reveals that the restored image has little or no artifacts.
Use of heat pipes in electronic hardware
NASA Technical Reports Server (NTRS)
Graves, J. R.
1977-01-01
A modular, multiple output power converter was developed in order to reduce costs of space hardware in future missions. The converter is of reduced size and weight, and utilizes advanced heat removal techniques, in the form of heat pipes which remove internally generated heat more effectively than conventional methods.
Deschênes, Philippe; Chano, Frédéric; Dionne, Léa-Laurence; Pittet, Didier; Longtin, Yves
2017-08-01
The efficacy of the World Health Organization (WHO)-recommended handwashing technique against Clostridium difficile is uncertain, and whether it could be improved remains unknown. Also, the benefit of using a structured technique instead of an unstructured technique remains unclear. This study was a prospective comparison of 3 techniques (unstructured, WHO, and a novel technique dubbed WHO shortened repeated [WHO-SR] technique) to remove C difficile. Ten participants were enrolled and performed each technique. Hands were contaminated with 3 × 10 6 colony forming units (CFU) of a nontoxigenic strain containing 90% spores. Efficacy was assessed using the whole-hand method. The relative efficacy of each technique and of a structured (either WHO or WHO-SR) vs an unstructured technique were assessed by Mann-Whitney U test and Wilcoxon signed-rank test. The median effectiveness of the unstructured, WHO, and WHO-SR techniques in log 10 CFU reduction was 1.30 (interquartile range [IQR], 1.27-1.43), 1.71 (IQR, 1.34-1.91), and 1.70 (IQR, 1.54-2.42), respectively. The WHO-SR technique was significantly more efficacious than the unstructured technique (P = .01). Washing hands with a structured technique was more effective than washing with an unstructured technique (median, 1.70 vs 1.30 log 10 CFU reduction, respectively; P = .007). A structured washing technique is more effective than an unstructured technique against C difficile. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
Chávez Rossell, Miguel
2012-01-01
The ingestion of a foreign body is one of the most common endoscopic emergencies. Foreign bodies in the upper gastrointestinal tract should be extracted as soon as possible to avoid serious complications such as perforation o bleeding. However, removals of foreign bodies with sharp edges are very difficult and can develop complications during their removal. Various devices have therefore been developed to prevent mucosal injury from the sharp edges during endoscopic extraction. We report a new technique for the successful foreign body extraction of upper digestive tract using the cap from six shooter variceal banding reused. We present 17 cases (9 males and 8 females). The types of foreign bodies removed were: chicken bones (n:7), fish bones (n:3), denture prosthesis (n:2), food bolus (n:2), long pin (n:1), golden thumb tack (n: 1) and press-through package (n:1). There were no complications. This new technique is safe and effective. Highlights its advantages: enhanced sight pharyngo esophageal junction, foreign bodies disimpact at that level, food bolus suck, avoid sharp object damage mucosal or scope and decrease time removal.
Hseu, Zeng-Yei; Huang, Yu-Tuan; Hsi, Hsing-Cheng
2014-09-01
When a contaminated site contains pollutants including both nonvolatile metals and Hg, one single remediation technology may not satisfactorily remove all contaminants. Therefore, in this study, chemical extraction and thermal treatment were combined as a remediation train to remove heavy metals, including Hg, from contaminated soil. A 0.2 M solution of ethylenediamine tetraacetic acid (EDTA) was shown to be the most effective reagent for extraction of considerable amounts of Cu, Pb, and Zn (> 50%). Hg removal was ineffective using 0.2 M EDTA, but thermogravimetric analysis suggested that heating to 550 degrees C with a heating rate of 5 degrees C/min for a duration of 1 hr appeared to be an effective approach for Hg removal. With the employment of thermal treatment, up to 99% of Hg could be removed. However executing thermal treatment prior to chemical extraction reduced the effectiveness of the subsequent EDTA extraction because nonvolatile heavy metals were immobilized in soil aggregates after the 550 degrees C treatment. The remediation train of chemical extraction followed by thermal treatment appears to remediate soils that have been contaminated by many nonvolatile heavy metals and Hg. Implications: A remediation train conjoining two or more techniques has been initialized to remove multiple metals. Better understandings of the impacts of treatment sequences, namely, which technique should be employed first on the soil properties and the decontamination efficiency, are in high demand. This study provides a strategy to remove multiple heavy metals including Hg from a contaminated soil. The interactions between thermal treatment and chemical extraction on repartitioning of heavy metals was revealed. The obtained results could offer an integrating strategy to remediate the soil contaminated with both heavy metals and volatile contaminants.
Bone preserving techniques for explanting the well-fixed cemented acetabular component.
Stevens, Jarrad; Macpherson, Gavin; Howie, Colin
2018-06-01
Removal of a well-fixed, cemented acetabular component at the time of revision hip surgery can be complex. It is essential to remove the implant and cement mantle in a timely fashion while preserving bone stock and osseous integrity. The biomechanical properties of polymethylmethacrylate cement and polyethylene can be utilised to aid with the removal of well cemented implants which are often harder than the surrounding bone. While removal of loose components may be relatively straightforward, the challenge for the revision arthroplasty surgeon often involves the removal of well-fixed implants. Here, we present three established techniques for the removal of a well-fixed cemented acetabular component and one novel modification we have described before. We collate and review four techniques for removing well-fixed cemented acetabular implants that utilise the different biomechanical properties of bone cement and polyethylene. These techniques are illustrated with a photographic series utilising saw bones. A step-by-step approach to our new technique is shown in photographs, both in the clinical setting and with a "Sawbone". This is accompanied by a clinical video that details the surgical technique in its entirety. These techniques utilise different biomechanical principles to extract the acetabular component. Each technique has advantages and disadvantages. Our new technique is a simplification of a previously published extraction manoeuvre that utilises tensile force between cement and the implant to remove the polyethylene cup. This is a safe and reproducible technique in patients with a well-fixed cemented acetabular implant. Understanding the biomechanical properties of polymethylmethacrylate bone cement and polyethylene can aid in the safe removal of a well-fixed cemented acetabular component in revision hip surgery. The optimal technique for removal of a cemented acetabular component varies depending on a number of patient and implant factors. This summary of the available techniques will be of interest to revision arthroplasty surgeons.
Removal of Cr(VI) from Aqueous Environments Using Micelle-Clay Adsorption
Qurie, Mohannad; Khamis, Mustafa; Manassra, Adnan; Ayyad, Ibrahim; Nir, Shlomo; Scrano, Laura; Bufo, Sabino A.; Karaman, Rafik
2013-01-01
Removal of Cr(VI) from aqueous solutions under different conditions was investigated using either clay (montmorillonite) or micelle-clay complex, the last obtained by adsorbing critical micelle concentration of octadecyltrimethylammonium ions onto montmorillonite. Batch experiments showed the effects of contact time, adsorbent dosage, and pH on the removal efficiency of Cr(VI) from aqueous solutions. Langmuir adsorption isotherm fitted the experimental data giving significant results. Filtration experiments using columns filled with micelle-clay complex mixed with sand were performed to assess Cr(VI) removal efficiency under continuous flow at different pH values. The micelle-clay complex used in this study was capable of removing Cr(VI) from aqueous solutions without any prior acidification of the sample. Results demonstrated that the removal effectiveness reached nearly 100% when using optimal conditions for both batch and continuous flow techniques. PMID:24222757
The ‘cut and push’ technique: is it really safe?
Peacock, Oliver; Singh, Rajeev; Cole, Andrew; Speake, William
2012-01-01
Percutaneous endoscopic gastrostomy (PEG) feeding is routinely used as an endoscopic and effective method for providing enteral nutrition in those whose oral access has been diminished or lost. One technique for removal of the PEG is cutting the tube at the skin level and allowing the tube and internal flange to pass spontaneously. This is known as the ‘cut and push’ method. Several studies have concluded that the ‘cut and push’ method is a safe and cost-effective method. This case demonstrates a rare cause of small bowel obstruction following the ‘cut and push’ method for PEG replacement, with only a few other cases been reported. This method of removal should be avoided in patients with previous abdominal surgery. It is important that the PEG flange is retrieved endoscopically or an alternative PEG tube (designed to be completely removed through the skin) is used to prevent this complication occurring in such individuals. PMID:22847571
Graphene and Graphene Derivatives for Pharmaceutical Residual Removal from Drinking Water
NASA Astrophysics Data System (ADS)
Yu, Ming; Zhang, Haifeng
Strategy to keeping pharmaceuticals out of the nation's water supplies is the most essential and long-term procedure, while improving effective filtering systems at water treatment plants or at resident home is more practical and efficient. Current techniques including oxidation/ozonation, activated carbons, and filtration using membranes are relatively efficient when the concentration of pharmaceutical residues in the aquatic ecosystem is high, while when the concentration is relatively low, no one effective technique can remove so many different pharmaceuticals. To overcome such significant limitation, we are seeking to develop graphene based materials for pharmaceutical residual removal from drinking water and to initiate the study on dealing with this issue through fundamental understanding. Our results have shown that the graphene/graphene derivate could possess high adsorption rate to pharmaceutical residues (e.g., estradiol), promising their potential applications for pharmaceutical contamination removal from drinking water. Detailed information about the activities of the graphene with a variety of biomolecules, the type of adsorptions, and the effects of the attached hydroxyl, epoxyl, and carboxyl functional groups will be presented in the Meeting. The authors acknowledge computing resource support from the Cardinal Research Cluster at the University of Louisville.
Ersev, H; Yilmaz, B; Dinçol, M E; Dağlaroğlu, R
2012-08-01
To evaluate residual root filling material following removal of three newly developed root canal sealers used with a matched-taper single-cone root filling technique and to compare the efficacy of ProTaper Universal rotary retreatment instruments with that of a conventional manual technique. The canals of 120 palatal roots in maxillary molar teeth were instrumented with EndoWave nickel-titanium rotary instruments and filled using Hybrid Root SEAL, EndoSequence BC Sealer, Activ GP system or AH Plus with matched-taper single gutta-percha cones. The root fillings were then removed with ProTaper Universal retreatment rotary instruments or a manual technique. Buccolingual and proximal digital radiographs of the roots were exposed to determine the area of remaining filling material in the coronal, middle and apical thirds. The area percentages of remaining filling material in each third and total canal area were calculated. Data were analysed statistically with Kruskal-Wallis and Mann-Whitney U-tests. The level of significance was set at P<0.05. Irrespective of the sealer type and retreatment technique, filling material could not be removed completely from the root canals. Significantly, more remaining filling material was observed in the apical third (P<0.05). When comparing the sealers, the only significant difference was detected between AH Plus/manual and Activ GP/manual groups with respect to residual material in the total canal area (P<0.05). There were no significant differences between manual and ProTaper groups. When using gross radiographic criteria, the Activ GP was more effectively removed from root canals than AH Plus with hand instrumentation. Hybrid Root SEAL, EndoSequence BC Sealer and AH Plus were removed to a similar extent. ProTaper Universal retreatment instruments were as safe and effective as hand instruments in reaching the working length. © 2012 International Endodontic Journal.
Nitrogen removal from digested slurries using a simplified ammonia stripping technique.
Provolo, Giorgio; Perazzolo, Francesca; Mattachini, Gabriele; Finzi, Alberto; Naldi, Ezio; Riva, Elisabetta
2017-11-01
This study assessed a novel technique for removing nitrogen from digested organic waste based on a slow release of ammonia that was promoted by continuous mixing of the digestate and delivering a continuous air stream across the surface of the liquid. Three 10-day experiments were conducted using two 50-L reactors. In the first two, nitrogen removal efficiencies were evaluated from identical digestates maintained at different temperatures (30°C and 40°C). At the start of the first experiment, the digestates were adjusted to pH 9 using sodium hydroxide, while in the second experiment pH was not adjusted. The highest ammonia removal efficiency (87%) was obtained at 40°C with pH adjustment. However at 40°C without pH adjustment, removal efficiencies of 69% for ammonia and 47% for total nitrogen were obtained. In the third experiment two different digestates were tested at 50°C without pH adjustment. Although the initial chemical characteristics of the digestates were different in this experiment, the ammonia removal efficiencies were very similar (approximately 85%). Despite ammonia removal, the pH increased in all experiments, most likely due to carbon dioxide stripping that was promoted by temperature and mixing. The technique proved to be suitable for removing nitrogen following anaerobic digestion of livestock manure because effective removal was obtained at natural pH (≈8) and 40°C, common operating conditions at typical biogas plants that process manure. Furthermore, the electrical energy requirement to operate the process is limited (estimated to be 3.8kWhm -3 digestate). Further improvements may increase the efficiency and reduce the processing time of this treatment technique. Even without these advances slow-rate air stripping of ammonia is a viable option for reducing the environmental impact associated with animal manure management. Copyright © 2017 Elsevier Ltd. All rights reserved.
Laser Tattoo Removal: A Clinical Update
Ho, Stephanie GY; Goh, Chee Leok
2015-01-01
Techniques for tattoo removal have evolved significantly over the years. The commonly used Quality-switched (QS) ruby, alexandrite, and Nd:YAG lasers are the traditional workhorses for tattoo removal. Newer strategies using combination laser treatments, multi-pass treatments, and picosecond lasers offer promising results. The tattoo color and skin type of the patient are important considerations when choosing the appropriate laser. Standard protocols can be developed for the effective and safe treatment of tattoos. PMID:25949017
Development of bimetal oxide doped multifunctional polymer nanocomposite for water treatment
NASA Astrophysics Data System (ADS)
Saxena, Swati; Saxena, Umesh
2016-08-01
Bimetal oxide doped polymer nanocomposite was developed using Alumina and Iron (III) Oxide as nanoparticles with Nylon 6, 6 and Poly (sodium-4-styrenesulphonate) as polymer matrix for removal of pollutants from water. The blend sample of polymers was prepared by well established solution blending technique and their nanocomposite samples were prepared through dispersion technique during the solution casting of blend sample. The fabricated composites were characterized adopting FTIR, XRD, FESEM and EDX techniques. XRD and FESEM were used for morphological characterization of nano phase, while FTIR and EDX analysis were adopted for characterization of chemical moieties in composites. In the study of pollutant removal capacities of prepared composites, 6 % nanocomposite provided the best results. It exhibited the maximum removal of all parameters. The removal of total alkalinity was 66.67 %, total hardness 42.85 %, calcium 66.67 %, magnesium 25 %, chloride 58.66 %, nitrate 34.78 %, fluoride 63.85 %, TDS 41.27 % and EC was up to the level of 41.37 % by this composite. The study is a step towards developing multifunctional, cost-effective polymer nanocomposites for water remediation applications.
Hinkson, Larry; Suermann, Mia Amelie; Hinkson, Susan; Henrich, Wolfgang
2017-08-01
The primary objective is to assess the reduction in manual removal of placenta with the Windmill technique of placenta delivery in patients with retained placenta. The Windmill technique involves the application of continuous 360° umbilical cord traction and rotation in such a manner as to be perpendicular to the direction of the birth canal at the level of the introitus. This rotation through 360° is repeated slowly with movement akin to the motion of the blades of a windmill. We performed a 3-year retrospective case-control study at the Charité University Hospital in Berlin. Patients with a retained placenta more than 30min following failed traditional interventions were consented and offered the Windmill technique of placenta delivery. Study cases were compared to controls where an operative manual removal of placenta was performed. Patients with suspected placenta implantation problems, uterine atony, bleeding due to vaginal tract injury and coagulation disturbances were excluded. Over the study period 14 patients were recruited to the study arm and 17 patients were in the control group. With the Windmill technique for retained placenta, 86% (12/14, p<0.001) of patients avoided invasive operative manual removal of the placenta in theatre. There was a statistically significant reduction in mean blood loss (429ml vs 724ml, p=0.001) and mean postoperative fall in hemoglobin values (1.3g/dl vs 2.5g/dl, p=0.04). There was a reduction in the time to delivery of the placenta, antibiotic prophylaxis and use of general anesthesia. The Windmill technique for the delivery of the retained placenta is a simple, safe, effective and easy to teach technique that reduces invasive operative manual removal of the placenta, postpartum blood loss and delay in the placenta delivery. This innovative technique can also be a lifesaving intervention especially in areas with limited or no access to operative facilities. Copyright © 2017 Elsevier B.V. All rights reserved.
Tringali, Andrea; Blero, Daniel; Boškoski, Ivo; Familiari, Pietro; Perri, Vincenzo; Devière, Jacques; Costamagna, Guido
2014-06-01
Removal of biliary Fully Covered Self Expandable Metal Stents can fail due to stent migration and/or hyperplastic ingrowth/overgrowth. A case series of 5 patients with benign biliary strictures (2 post-cholecystectomy, 2 following liver transplantation and 1 related to chronic pancreatitis) is reported. The biliary stricture was treated by temporary insertion of Fully Covered Self Expandable Metal Stents. Stent removal failed due to proximal stent migration and/or overgrowth. Metal stent removal was attempted a few weeks after the insertion of another Fully Covered Metal Stent into the first one. The inner Fully Covered Self Expandable Metal Stent compressed the hyperplastic tissue, leading to the extraction of both the stents in all cases. Two complications were reported as a result of the attempt to stents removal (mild pancreatitis and self-limited haemobilia). In the present series, the "SEMS in SEMS" technique revealed to be effective when difficulties are encountered during Fully Covered Self Expandable Metal Stents removal. Copyright © 2014 Editrice Gastroenterologica Italiana S.r.l. Published by Elsevier Ltd. All rights reserved.
False colors removal on the YCr-Cb color space
NASA Astrophysics Data System (ADS)
Tomaselli, Valeria; Guarnera, Mirko; Messina, Giuseppe
2009-01-01
Post-processing algorithms are usually placed in the pipeline of imaging devices to remove residual color artifacts introduced by the demosaicing step. Although demosaicing solutions aim to eliminate, limit or correct false colors and other impairments caused by a non ideal sampling, post-processing techniques are usually more powerful in achieving this purpose. This is mainly because the input of post-processing algorithms is a fully restored RGB color image. Moreover, post-processing can be applied more than once, in order to meet some quality criteria. In this paper we propose an effective technique for reducing the color artifacts generated by conventional color interpolation algorithms, in YCrCb color space. This solution efficiently removes false colors and can be executed while performing the edge emphasis process.
Removing the echoes from terahertz pulse reflection system and sample
NASA Astrophysics Data System (ADS)
Liu, Haishun; Zhang, Zhenwei; Zhang, Cunlin
2018-01-01
Due to the echoes both from terahertz (THz) pulse reflection system and sample, the THz primary pulse will be distorted. The system echoes include two types. One preceding the main peak probably is caused by ultrafast laser pulse and the other at the back of the primary pulse is caused by the Fabry-Perot (F-P) etalon effect of detector. We attempt to remove the corresponding echoes by using two kinds of deconvolution. A Si wafer of 400μm was selected as the tested sample. Firstly, the method of double Gaussian filter (DGF) decnvolution was used to remove the systematic echoes, and then another deconvolution technique was employed to eliminate the two obvious echoes of the sample. The ultimate results indicated: although the combination of two deconvolution techniques could not entirely remove the echoes of sample and system, the echoes were largely reduced.
Removal of cadmium (II) from simulated wastewater by ion flotation technique
2013-01-01
A separation technique which has recently received a sharp increase in research activities is “ion flotation”. This technique has four important advantages for treating wastewaters: low energy consumption, small space requirements, small volume of sludge and acting selectively. The present study aims to optimize parameters of ion flotation for cadmium removal in simulated wastewater at laboratory scale. It was obtained on the reaction between Cd2+ and sodium dodecylesulfate (SDS) collector followed by flotation with ethanol as frother. Test solution was prepared by combining the required amount of cadmium ion, SDS and necessary frother or sodium sulfate solution. All experiments were carried out in a flotation column at laboratory temperature (27°C), adjusted pH = 4 and 120 minutes. The different parameters (namely: flow rate, cadmium, SDS and frother concentrations and ionic strength) influencing the flotation process were examined. The best removal efficiency obtained at a collector-metal ratio of 3:1 in 60 min with flow rate of 150 mL/min was 84%. The maximum cadmium removal was 92.1% where ethanol was introduced at a concentration 0.4% to flotation column with above conditions. The obtained results were promising, as both cadmium and collector were effectively removed from wastewater. Hence, the application of ion flotation for metal ions removal from effluents seems to be efficient. PMID:23388386
Yamada, Kazunori; Inoue, Tomoaki; Akiba, Yuji; Kashiwada, Ayumi; Matsuda, Kiyomi; Hirata, Mitsuo
2006-10-01
Enzymatic removal of p-alkylphenols from aqueous solutions was investigated through the two-step approach, the quinone conversion of p-alkylphenols with mushroom tyrosinase (EC 1.14.18.1) and the subsequent adsorption of quinone derivatives enzymatically generated on chitosan beads at pH 7.0 and 45 degrees C as the optimum conditions. This technique is quite effective for removal of various p-alkylphenols from an aqueous solution. The % removal values of 97-100% were obtained for p-n-alkylphenols with carbon chain lengths of 5 to 9. In addition, removal of other p-alkylphenols was enhanced by increasing either the tyrosinase concentration or the amount of added chitosan beads, and their % removal values reached >93 except for 4-tert-pentylphenol. This technique was also applicable to remove 4-n-octylphenol (4NOP) and 4-n-nonylphenol (4NNP) as suspected endocrine disrupting chemicals. The reaction of quinone derivatives enzymatically generated with the chitosan's amino groups was confirmed by the appearance of peaks for UV-visible spectrum measurements of the chitosan films incubated in the p-alkylphenol and tyrosinase mixture solutions. In addition, 4-tert-pentylphenol underwent tyrosinase-catalyzed oxidation in the presence of hydrogen peroxide.
NASA Astrophysics Data System (ADS)
Han, Jinghua; Cui, Xudong; Wang, Sha; Feng, Guoying; Deng, Guoliang; Hu, Ruifeng
2017-10-01
Paint removal by laser ablation is favoured among cleaning techniques due to its high efficiency. How to predict the optimal laser parameters without producing damage to substrate still remains challenging for accurate paint stripping. On the basis of ablation morphologies and combining experiments with numerical modelling, the underlying mechanisms and the optimal conditions for paint removal by laser ablation are thoroughly investigated. Our studies suggest that laser paint removal is dominated by the laser vaporization effect, thermal stress effect and laser plasma effect, in which thermal stress effect is the most favoured while laser plasma effect should be avoided during removal operations. Based on the thermodynamic equations, we numerically evaluated the spatial distribution of the temperature as well as thermal stress in the paint and substrate under the irradiation of laser pulse at 1064 nm. The obtained curves of the paint thickness vs. threshold fluences can provide the reference standard of laser parameter selection in view of the paint layer with different thickness. A multi-pulse model is proposed and validated under a constant laser fluence to perfectly remove a thicker paint layer. The investigations and the methods proposed here might give hints to the efficient operations on the paint removal and lowering the risk of substrate damages.
[Orbital decompression in Grave's disease: comparison of techniques].
Sellari-Franceschini, S; Berrettini, S; Forli, F; Bartalena, L; Marcocci, C; Tanda, M L; Nardi, M; Lepri, A; Pinchera, A
1999-12-01
Grave's ophthalmopathy is an inflammatory, autoimmune disorder often associated with Grave's disease. The inflammatory infiltration involves the retrobulbar fatty tissue and the extrinsic eye muscles, causing proptosis, extraocular muscle dysfunction and often diplopia. Orbital decompression is an effective treatment in such cases, particularly when resistant to drugs and external radiation therapy. This work compares the results of orbital decompression performed by removing: a) the medial and lateral walls (Mourits technique) in 10 patients (19 orbits) and b) the medial and lower walls (Walsh-Ogura technique) in 17 patients (31 orbits). The results show that removing the floor of the orbit enables better reduction of proptosis but more easily leads to post-operative diplopia. Thus it proves necessary to combine the two techniques, modifying the surgical approach on a case-by-case basis.
Ben Hariz, Ichrak; Al Ayni, Foued; Monser, Lotfi
2014-01-01
The adsorption of sulfur compounds from petroleum refinery wastewater on a chemically modified activated carbon (MAC) was investigated. The modification technique (nitric acid, hydrogen peroxide and thermal modification) enhanced the removal capacity of carbon and therefore decreases cost-effective removal of sulfide from refinery wastewater. Adsorption equilibrium and kinetics data were determined for sulfur removal from real refinery wastewater. The data were evaluated according to several adsorption isotherm and kinetics models. The Freundlich isotherm fitted well with the equilibrium data of sulfur on different adsorbents, whereas the kinetics data were best fitted by the pseudo-second-order model. Insights of sulfide removal mechanisms indicated that the sorption was controlled through the intraparticle diffusion mechanism with a significant contribution of film diffusion. The MAC adsorbent was found to have an effective removal capacity of approximately 2.5 times that of non-modified carbon. Using different MAC, sulfides were eliminated with a removal capacity of 52 mg g(-1). Therefore, MAC can be utilized as an effective and less expensive adsorbent for the reduction of sulfur in refinery wastewater.
Hall, Francis X
2006-12-01
The goal was to monitor the effectiveness of the Coast Guard Yard's lead program by comparing a shipyard period in 1991 to one in 2002-2003. Comparisons of airborne lead levels by paint removal techniques, airborne lead levels by welding techniques, and blood lead levels of workers were evaluated by chi2 analysis. Airborne lead levels in paint removal techniques decreased over time for all methods used. Airborne lead levels in welding techniques decreased over time for all methods used. Blood lead levels of the high-risk group revealed a 2-fold reduction (prevalence rate ratio = 8.3; 95% confidence interval, 3.7-18.6) and in the low-risk group revealed a 1.6-fold reduction (prevalence rate ratio = 6.2; 95% confidence interval, 0.86-44.7). The Coast Guard Yard runs an effective lead program that exceeds the national Healthy People 2010 goal for lead. The results validate the Coast Guard Yard's use of air-line respirators and lead-free paint on all vessels.
Sato, Mamoru; Akai, Hiroko; Saito, Yuichi; Takase, Tsugiko; Kikunaga, Hidetoshi; Sekiya, Nobuhito; Ohtsuki, Tsutomu; Yamaguchi, Katsuhiko
2017-04-04
The effectiveness of a decontamination methodology whereby herbaceous plants were grown through different materials covering the soil surface followed by subsequent removal of the material, associated plant tissues and attached soil on 137 Cs removal from soil was evaluated. Revegetation netting sown with Kentucky bluegrass and white clover had a high effectiveness in 137 Cs removal when rolling up the plants, roots, and rhizosphere soil approximately 6 months after sowing. The removal rate was lower when there was higher 137 Cs vertical migration down the soil profile. The maximum removal effectiveness of 93.1% was observed by rolling up fertilized Kentucky bluegrass with a well-developed root mat without netting, indicating that applying nutrients to encourage the development of roots or root mats in the 3 cm topsoil rhizosphere is an efficient technology to increase the decontamination effect of plant removal in orchards. Netting and weeding were able to remove up to 80% of 137 Cs in the soil without the use of heavy machinery. There was a significant relationship between the removal ratio and the removed soil weight per area. Using the relationship on the site below the canopy, removal of 14.3 kg m -2 DW soil would achieve a removal ratio of 80%. The effectiveness of the technique will decrease with time as radiocaesium migrates down the soil profile but this would be expected to occur slowly in many soils. Copyright © 2017 Elsevier Ltd. All rights reserved.
Hammad, Mohammad; Qualtrough, Alison; Silikas, Nick
2008-11-01
The aim of this study was to measure the remaining filling volume of different obturation materials from root-filled extracted teeth by using 2 removal techniques. Eighty single-rooted teeth were collected and decoronated, and the root canal was prepared by using the ProTaper nickel-titanium rotary files. The teeth were randomly allocated into 4 groups, and each group was obturated by using a different material. Group 1 was filled with gutta-percha and TubliSeal sealer, group 2 was filled with EndoRez points and EndoRez sealer, group 3 was filled with RealSeal points and RealSeal sealer, and Group 4 was filled with a gutta-percha point and GuttaFlow sealer. Teeth were scanned with a micro-computed tomography scan, and then root fillings were removed by using ProTaper retreatment files or hand K-files. Teeth were scanned again, and volume measurements were carried out with micro-computed tomography software. Statistical analysis showed significant differences between the 2 removal techniques for gutta-percha and for both techniques between gutta-percha and the other groups. The present study showed that all tested filling materials were not completely removed during retreatment by using hand or rotary files. Gutta-percha was more efficiently removed by using hand K-files.
Safe removal of upper esophageal coins by using Magill forceps: two centers' experience.
Cetinkursun, Salih; Sayan, Ali; Demirbag, Suzi; Surer, Ilhami; Ozdemir, Tunc; Arikan, Ahmet
2006-01-01
Coin ingestion with subsequent esophageal coin impaction is common in children. Considerable debate surrounds the choice of technique for the removal of esophageal coins. This study demonstrates a minimally invasive technique for upper esophageal coin extraction. A retrospective review was conducted of 165 children who had upper esophageal coins extracted by using a Magill forceps. One hundred fifty-six coins (96.4%) were successfully removed without any complications. The average time taken to remove the coin was 33 seconds. Use of the Magill forceps technique minimizes instrumentation of the esophagus and is an easy, safe technique for removing coins from the upper end of the esophagus.
Ferreira, Cimara Fortes; Shafter, Mohamed Amer; Jain, Vinay; Wicks, Russel Anthony; Linder, Erno; Ledo, Carlos Alberto da Silva
2018-02-13
Extruded cement during dental implant crown cementation may cause peri-implant diseases if not removed adequately. Evaluate the efficiency of removal of cement after cementation of implant crowns using an experimental "circular crisscross flossing technique (CCCFT) flossing technique, compared to the conventional "C" shape flossing technique (CSFT). Twenty-four patients rendered 29 experimental and 29 control crowns. Prefabricated abutments were secured to the implant with the margins at least 1 mm subgingivally. The abutments were scanned using CADCAM technology and Emax crowns were fabricated in duplicates. Each crown was cemented separately and excess cement was removed using the CSFT and the CCFT techniques. After completion of cementation was completed, the screw access holes were accessed and the crown was unscrewed along with the abutment. The samples were disinfected using 70% ethanol for 10 minutes. Crowns were divided into 4 parts using a marker in order to facilitate measurement data collection. Vertical and horizontal measurements were made for extruded cement for each control and experimental groups by means of a digital microscope. One-hundred and seventeen measurements were made for each group. Mann-Whitney test was applied to verify statistical significance between the groups. The CCFT showed a highly statistically significant result (104.8 ± 13.66, p<0.0001) for cement removal compared with the CSFT (291.8 ± 21.96, p<0.0001). The vertical lengths of the extruded cement showed a median of 231.1 µm (IQR = 112.79 -398.39) and 43.62 µm (IQR = 0 - 180.21) for the control and the experimental flossing techniques, respectively. The horizontal length of the extruded cement showed a median of 987.1 µm (IQR = 476.7 - 1,933.58) and 139.2 µm (IQR = 0 - 858.28) for the control and the experimental flossing techniques, respectively. The CCFT showed highly statistically significant less cement after implant crowns cementation when compared with the CSFT.
Advanced Coating Removal Techniques
NASA Technical Reports Server (NTRS)
Seibert, Jon
2006-01-01
An important step in the repair and protection against corrosion damage is the safe removal of the oxidation and protective coatings without further damaging the integrity of the substrate. Two such methods that are proving to be safe and effective in this task are liquid nitrogen and laser removal operations. Laser technology used for the removal of protective coatings is currently being researched and implemented in various areas of the aerospace industry. Delivering thousands of focused energy pulses, the laser ablates the coating surface by heating and dissolving the material applied to the substrate. The metal substrate will reflect the laser and redirect the energy to any remaining protective coating, thus preventing any collateral damage the substrate may suffer throughout the process. Liquid nitrogen jets are comparable to blasting with an ultra high-pressure water jet but without the residual liquid that requires collection and removal .As the liquid nitrogen reaches the surface it is transformed into gaseous nitrogen and reenters the atmosphere without any contamination to surrounding hardware. These innovative technologies simplify corrosion repair by eliminating hazardous chemicals and repetitive manual labor from the coating removal process. One very significant advantage is the reduction of particulate contamination exposure to personnel. With the removal of coatings adjacent to sensitive flight hardware, a benefit of each technique for the space program is that no contamination such as beads, water, or sanding residue is left behind when the job is finished. One primary concern is the safe removal of coatings from thin aluminum honeycomb face sheet. NASA recently conducted thermal testing on liquid nitrogen systems and found that no damage occurred on 1/6", aluminum substrates. Wright Patterson Air Force Base in conjunction with Boeing and NASA is currently testing the laser remOval technique for process qualification. Other applications of liquid nitrogen operations include cutting of both soft and hard materials. While the laser will not cut materials, it can be used to roughen surfaces and to remove other materials from the substrate including oil, grease, and mold. The space program can benefit from several of these applications with the need for precise removal of coatings and other organic compounds in areas adjacent to sensitive space flight hardware. Significant advantages are evident when comparing liquid nitrogen and laser removal operations over current techniques of media blasting and sanding.
Atomic Oxygen Treatment as a Method of Recovering Smoke Damaged Paintings. Revised
NASA Technical Reports Server (NTRS)
Rutledge, Sharon K.; Banks, Bruce A.; Forkapa, Mark; Stueber, Thomas; Sechkar, Edward; Malinowski, Kevin
1999-01-01
A noncontact technique is described that uses atomic oxygen, generated under low pressure in the presence of nitrogen, to remove soot and charred varnish from the surface of a painting. The process, which involves surface oxidation, permits control of the amount of surface material removed. The effectiveness of the process was evaluated by reflectance measurements from selected areas made during the removal of soot from acrylic gesso, ink on paper, and varnished oil paint substrates. For the latter substrate, treatment also involved the removal of damaged varnish and paint binder from the surface.
Shear stress cleaning for surface departiculation
NASA Technical Reports Server (NTRS)
Musselman, R. P.; Yarbrough, T. W.
1986-01-01
A cleaning technique widely used by the nuclear utility industry for removal of radioactive surface contamination has proven effective at removing non-hazardous contaminant particles as small as 0.1 micrometer. The process employs a controlled high velocity liquid spray inside a vapor containment enclosure to remove particles from a surface. The viscous drag force generated by the cleaning fluid applies a shear stress greater than the adhesion force that holds small particles to a substrate. Fluid mechanics and field tests indicate general cleaning parameters.
Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew
2014-03-01
Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.
NASA Astrophysics Data System (ADS)
Ishimoto, Jun; Abe, Haruto; Ochiai, Naoya
The fundamental characteristics of the cryogenic single-component micro-nano solid nitrogen (SN2) particle production using super adiabatic Laval nozzle and its application to the physical photo resist removal-cleaning technology are investigated by a new type of integrated measurement coupled computational technique. As a result of present computation, it is found that high-speed ultra-fine SN2 particles are continuously generated due to the freezing of liquid nitrogen (LN2) droplets induced by rapid adiabatic expansion of transonic subcooled two-phase nitrogen flow passing through the Laval nozzle. Furthermore, the effect of SN2 particle diameter, injection velocity, and attack angle to the wafer substrate on resist removal-cleaning performance is investigated in detail by integrated measurement coupled computational technique.
Zhang, Zhiyin; Lei, Zhongfang; Zhang, Zhenya; Sugiura, Norio; Xu, Xiaotian; Yin, Didi
2007-11-19
Soil infiltration treatment (SIT) was proved to be an effective and low-cost treatment technique for decentralized effluents in the areas without perfect sewage systems. Field-scale experiments were conducted under several conditions to assess organics removals through a shallow soil infiltration treatment (SSIT, with effective depth 0.3m) of combined wastewater (discharge from toilets, restaurants and a gas station), while bench-scale soil column experiments were performed in laboratory in parallel to investigate biological and abiological effects of this kind of system. From the start-up to the 10th month, the field SSIT trenches experienced the lowest and highest temperatures of the operation period in Shanghai and exhibited effective organics removals after maturation, with the highest removal rate 75.8% of chemical oxygen demand (COD), highest ultraviolet absorption at 254 nm (UV(254)) decrease by 67.2% and 35.2-100% removals of phenolic and phthalate pollutants. The laboratory results indicated that more organics could be removed in room-temperatured (25+/-2 degrees C) SSIT systems under different influent COD concentrations from 45 mg/l to 406 mg/l, and the highest total COD removal rate could reach 94.0%, in which biological effect accounted for 57.7-71.9%. The results showed that temperature and hydraulic loading rate were the most important factors influencing the removals of COD and organic pollutants in SSIT.
Over the last decade electrodialysis has emerged as an effective technique for removing accumulated reactant counterions (sodium and sulfate) and reaction products (orthophosphite) that interfere with the electroless nickel plating process, thus extending bath life by up to 50 me...
Removal of fluoride from drinking water using aluminum hydroxide coated rice husk ash.
Ganvir, Vivek; Das, Kalyan
2011-01-30
Fluoride content in groundwater that is greater than the WHO limit of 1.5mg/L, causes dental and skeletal fluorosis. In India, several states are affected with excess fluoride in groundwater. The problem is aggravated due to the lack of appropriate and user friendly defluoridation technology. Several fluoride removal techniques are reported in the literature amongst which the Nalgonda technique and use of activated alumina have been studied extensively. However a simple, efficient and cost effective technology is not available for widespread use in many affected regions. In this paper, we present a novel cost effective defluoridation method that is based on surface modification of rice husk ash (RHA) by coating aluminum hydroxide. RHA is obtained by burning rice/paddy husk which is an abundantly available and is an inexpensive raw material. The results showed excellent fluoride removal efficiency and the adsorption capacity was found to be between 9 and 10mg/g. Copyright © 2010 Elsevier B.V. All rights reserved.
Atomic Oxygen Treatment and Its Effect on a Variety of Artist's Media
NASA Technical Reports Server (NTRS)
Miller, Sharon K. R.; Banks, Bruce A.; Waters, Deborah L.
2005-01-01
Atomic oxygen treatment has been investigated as an unconventional option for art restoration where conventional methods have not been effective. Exposure of surfaces to atomic oxygen was first performed to investigate the durability of materials in the low Earth orbit environment of space. The use of the ground based environmental simulation chambers, developed for atomic oxygen exposure testing, has been investigated in collaboration with conservators at a variety of institutions, as a method to clean the surfaces of works of art. The atomic oxygen treatment technique has been evaluated as a method to remove soot and char from the surface of oil paint (both varnished and unvarnished), watercolors, acrylic paint, and fabric as well as the removal of graffiti and other marks from surfaces which are too porous to lend themselves to conventional solvent removal techniques. This paper will discuss the treatment of these surfaces giving an example of each and a discussion of the treatment results.
Photocatalytic degradation of textile dye using TiO2-activated carbon nanocomposite
NASA Astrophysics Data System (ADS)
Ghosh, Gourab; Basu, Sankhadeep; Saha, Sudeshna
2018-05-01
Rapid industrialisation has extended the use of dyes in various industrial applications in order to meet the escalating demands on consumer products. The toxicity level of a particular dye is very important due to its diverse effects on the environment and living organisms. Among all the techniques for dye removal, adsorption and photocatalysis are two important processes which are gaining much attention in recent years. In the present study activated carbon (adsorbent), TiO2 nanoparticles (photocatalyst) and their composite were used for dye removal. Prepared samples were characterized using standard characterization techniques such as XRD and SEM. Activated carbon was prepared from waste shells of Sterculia foetida. Mixture of activated carbon (activation temperature 600°C) and titania (calcined at 500°C) in the ratio 1:1 displayed greater dye removal efficiency than its individual components. Reusability study indicated that the mixture could effectively be used without further regeneration as very little loss in efficiency was observed after single cycle use.
A regenerable carbon dioxide removal and oxygen recovery system for the Japanese Experiment Module.
Otsuji, K; Hirao, M; Satoh, S
1987-01-01
The Japanese Space Station Program is now under Phase B study by the National Space Development Agency of Japan in participation with the U.S. Space Station Program. A Japanese Space Station participation will be a dedicated pressurized module to be attached to the U.S. Space Station, and is called Japanese Experiment Module (JEM). Astronaut scientists will conduct various experimental operations there. Thus an environment control and life support system is required. Regenerable carbon dioxide removal and collection technique as well as oxygen recovery technique has been studied and investigated for several years. A regenerable carbon dioxide removal subsystem using steam desorbed solid amine and an oxygen recovery subsystem using Sabatier methane cracking have a good possibility for the application to the Japanese Experiment Module. Basic performance characteristics of the carbon dioxide removal and oxygen recovery subsystem are presented according to the results of a fundamental performance test program. The trace contaminant removal process is also investigated and discussed. The solvent recovery plant for the regeneration of various industrial solvents, such as hydrocarbons, alcohols and so on, utilizes the multi-bed solvent adsorption and steam desorption process, which is very similar to the carbon dioxide removal subsystem. Therefore, to develop essential components including adsorption tank (bed), condenser. process controller and energy saving system, the technology obtained from the experience to construct solvent recovery plant can be easily and effectively applicable to the carbon dioxide removal subsystem. The energy saving efficiency is evaluated for blower power reduction, steam reduction and waste heat utilization technique. According to the above background, the entire environment control and life support system for the Japanese Experiment Module including the carbon dioxide removal and oxygen recovery subsystem is evaluated and proposed.
Patel, Premal Amrishkumar; Parra, Dimitri A; Bath, Ramnik; Amaral, Joao G; Temple, Michael J; John, Philip R; Connolly, Bairbre L
2016-06-01
To identify factors associated with adherence of implanted venous access port catheters in children and describe technical strategies for removing "stuck" ports. A retrospective single-center review of port removals was conducted between 2003 and 2012. Cases were identified through radiology reports. Clinical details (eg, demographics, disease, port dwell time, interventional techniques) were obtained through patient charts. Cases were classified as difficult removals if there was documented adherence to soft tissues or vein, or simple removals if no difficulty was recorded. Difficult removals were categorized and graded on increasing invasiveness of techniques required. Successful removal was defined as complete removal of the port catheter. Difficult removals were compared with simple removals for factors associated with difficult removal. Of all removals (N = 1,306), 58 were classified as difficult removals (4%). Using various techniques, 57 of 58 (98%) adherent port catheters were successfully removed. Factors identified with difficult removals included primary diagnosis of acute lymphoblastic leukemia (ALL) (78% vs 37%, P < .0001), age at insertion (3.7 y vs 5.4 y, P = .0019), and port dwell time (median 1,087 d vs 616 d, P < .0001). Difficulty removing port catheters in children is uncommon. Port catheters can usually be removed successfully using various IR techniques ranging in invasiveness. There is an association of difficult removal with early age at insertion, ALL diagnosis, and long port dwell time. Awareness of these factors may help physicians inform parents of potential difficulties and plan the removal procedure. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
ElHadidy, Ahmed M; Peldszus, Sigrid; Van Dyke, Michele I
2014-09-15
The effect of membrane fouling on the removal of enteric virus surrogates MS2 and φX174 bacteriophage by an ultrafiltration membrane was assessed under simulated full-scale drinking water treatment operating conditions. Filtration experiments of up to 8 days using either river or lake water ascertained how the membrane fouling layer affected virus removal. Organic carbon fractionation techniques identified potential foulants, including biopolymers, in the feed water and in the permeate. Hydraulically irreversible fouling could greatly improve the removal of both viruses at moderate and severe fouling conditions by up to 2.5 logs. Hydraulically reversible fouling increased virus removal only slightly, and increased removal of >0.5 log for both phage were only obtained under severe fouling conditions. The increase in virus removal due to irreversible and reversible fouling differed between the two water sources. As the degree of fouling increased, differences between the removal of the two phage decreased. Maintenance cleaning partially removed membrane foulants, however virus removal following maintenance cleaning was lower than that of the fouled membrane, it remained higher than that of the clean membrane. Copyright © 2014 Elsevier Ltd. All rights reserved.
David L. Parrott; John M. Lhotka; Jeffrey W. Stringer
2011-01-01
Difficulties in successful oak regeneration have led to the examination of various techniques to increase oak recruitment. To ensure sufficient regeneration, oak seedlings can be underplanted and used in conjunction with intermediate treatments, such as midstory removal, that create a light environment favorable to oak advance reproduction. This study examines the 5-...
Kim, Soon-Oh; Moon, Seung-Hyeon; Kim, Kyoung-Woong; Yun, Seong-Taek
2002-11-01
In order to remove toxic heavy metals from municipal wastewater sludges, the ex situ electrokinetic technique was studied at pilot scale. This study focused on the feasibility of the electrokinetic removal of heavy metals from sludge and the effectiveness of this technique on the variations of abiotic (physicochemical) and biotic (intracellular and extracellular) speciations of heavy metals using several analytical methods. Even though the sludge used was taken from a municipal wastewater treatment plant, the sludge contained relatively high concentrations of target metal contaminants (Cd = 6.8 mg/kg, Cr = 115.6 mg/kg, Cu = 338.7 mg/kg, and Pb = 62.8 mg/kg). The removal efficiencies of heavy metals were significantly dependent on their speciations in the sludge matrices. The electrokinetic removal efficiencies of abiotic heavy metals exceeded 70% for the mobile and weakly bound fractions, such as, the exchangeable and carbonate fractions and were lower than 35% for the strongly bound fractions, such as, the organic/sulfide and residual fractions. In the case of the biotic heavy metals, the removal efficiencies of the extracellular fractions were slightly higher than those of the intracellular fractions.
Sialoendoscopically assisted open sialolithectomy for removal of large submandibular hilar calculi.
Su, Yu-xiong; Liao, Gui-qing; Zheng, Guang-sen; Liu, Hai-chao; Liang, Yu-jie; Ou, De-ming
2010-01-01
The management of large hilar calculi is a technically challenging issue during sialoendoscopic surgery. The aim of the present study was to evaluate the clinical efficacy of sialoendoscopically assisted open sialolithectomy for the removal of large submandibular hilar calculi to avoid sialoadenectomy. The present study was undertaken among patients with sialolithiasis scheduled for sialoendoscopic surgery from August 2005 to October 2008. When we failed to remove large submandibular hilar stones intraductally, we performed sialoendoscopically assisted open sialolithectomy. The clinical characteristics, pre- and intraoperative data, and outcomes were documented in a prospective fashion. Of 78 consecutive patients with submandibular sialolithiasis, 18 were treated with sialoendoscopically assisted open sialolithectomy immediately after failure of intraductal removal of calculi by sialoendoscopy. For 17 patients, large hilar sialoliths were successfully removed using this surgical technique. The surgery failed in 1 patient with multiple sialoliths, and the procedure was converted to open sialoadenectomy. Temporary numbness of the tongue for 1 week postoperatively was documented in 3 patients. The patients were followed up for a median period of 18 months without any symptoms or signs of recurrence. Our results suggest that sialoendoscopically assisted open sialolithectomy is an effective and safe surgical technique to remove large submandibular hilar calculi.
Extracorporeal CO2 removal: Technical and physiological fundaments and principal indications.
Romay, E; Ferrer, R
2016-01-01
In recent years, technological improvements have reduced the complexity of extracorporeal membrane oxygenation devices. This have enabled the development of specific devices for the extracorporeal removal of CO2. These devices have a simpler configuration than extracorporeal membrane oxygenation devices and uses lower blood flows which could reduce the potential complications. Experimental studies have demonstrated the feasibility, efficacy and safety of extracorporeal removal of CO2 and some of its effects in humans. This technique was initially conceived as an adjunct therapy in patients with severe acute respiratory distress syndrome, as a tool to optimize protective ventilation. More recently, the use of this technique has allowed the emergence of a relatively new concept called "tra-protective ventilation"whose effects are still to be determined. In addition, the extracorporeal removal of CO2 has been used in patients with exacerbated hypercapnic respiratory failure with promising results. In this review we will describe the physiological and technical fundamentals of this therapy and its variants as well as an overview of the available clinical evidence, focused on its current potential. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.
Influence of removal of invisible fixation on the saccadic and manual gap effect.
Ueda, Hiroshi; Takahashi, Kohske; Watanabe, Katsumi
2014-01-01
Saccadic and manual reactions to a peripherally presented target are facilitated by removing a central fixation stimulus shortly before a target onset (the gap effect). The present study examined the effects of removal of a visible and invisible fixation point on the saccadic gap effect and the manual gap effect. Participants were required to fixate a central fixation point and respond to a peripherally presented target as quickly and accurately as possible by making a saccade (Experiment 1) or pressing a corresponding key (Experiment 2). The fixation point was dichoptically presented, and visibility was manipulated by using binocular rivalry and continuous flash suppression technique. In both saccade and key-press tasks, removing the visible fixation strongly quickened the responses. Furthermore, the invisible fixation, which remained on the display but suppressed, significantly delayed the saccadic response. Contrarily, the invisible fixation had no effect on the manual task. These results indicate that partially different processes mediate the saccadic gap effect and the manual gap effect. In particular, unconscious processes might modulate an oculomotor-specific component of the saccadic gap effect, presumably via subcortical mechanisms.
Slaughterhouse Wastewater Treatment by Combined Chemical Coagulation and Electrocoagulation Process
Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein
2012-01-01
Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD5 removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater. PMID:22768233
Slaughterhouse wastewater treatment by combined chemical coagulation and electrocoagulation process.
Bazrafshan, Edris; Kord Mostafapour, Ferdos; Farzadkia, Mehdi; Ownagh, Kamal Aldin; Mahvi, Amir Hossein
2012-01-01
Slaughterhouse wastewater contains various and high amounts of organic matter (e.g., proteins, blood, fat and lard). In order to produce an effluent suitable for stream discharge, chemical coagulation and electrocoagulation techniques have been particularly explored at the laboratory pilot scale for organic compounds removal from slaughterhouse effluent. The purpose of this work was to investigate the feasibility of treating cattle-slaughterhouse wastewater by combined chemical coagulation and electrocoagulation process to achieve the required standards. The influence of the operating variables such as coagulant dose, electrical potential and reaction time on the removal efficiencies of major pollutants was determined. The rate of removal of pollutants linearly increased with increasing doses of PACl and applied voltage. COD and BOD(5) removal of more than 99% was obtained by adding 100 mg/L PACl and applied voltage 40 V. The experiments demonstrated the effectiveness of chemical and electrochemical techniques for the treatment of slaughterhouse wastewaters. Consequently, combined processes are inferred to be superior to electrocoagulation alone for the removal of both organic and inorganic compounds from cattle-slaughterhouse wastewater.
Remediation of Chlorinated Solvent Plumes Using In-Situ Air Sparging—A 2-D Laboratory Study
Adams, Jeffrey A.; Reddy, Krishna R.; Tekola, Lue
2011-01-01
In-situ air sparging has evolved as an innovative technique for soil and groundwater remediation impacted with volatile organic compounds (VOCs), including chlorinated solvents. These may exist as non-aqueous phase liquid (NAPL) or dissolved in groundwater. This study assessed: (1) how air injection rate affects the mass removal of dissolved phase contamination, (2) the effect of induced groundwater flow on mass removal and air distribution during air injection, and (3) the effect of initial contaminant concentration on mass removal. Dissolved-phase chlorinated solvents can be effectively removed through the use of air sparging; however, rapid initial rates of contaminant removal are followed by a protracted period of lower removal rates, or a tailing effect. As the air flow rate increases, the rate of contaminant removal also increases, especially during the initial stages of air injection. Increased air injection rates will increase the density of air channel formation, resulting in a larger interfacial mass transfer area through which the dissolved contaminant can partition into the vapor phase. In cases of groundwater flow, increased rates of air injection lessened observed downward contaminant migration effect. The air channel network and increased air saturation reduced relative hydraulic conductivity, resulting in reduced groundwater flow and subsequent downgradient contaminant migration. Finally, when a higher initial TCE concentration was present, a slightly higher mass removal rate was observed due to higher volatilization-induced concentration gradients and subsequent diffusive flux. Once concentrations are reduced, a similar tailing effect occurs. PMID:21776228
Remediation of chlorinated solvent plumes using in-situ air sparging--a 2-D laboratory study.
Adams, Jeffrey A; Reddy, Krishna R; Tekola, Lue
2011-06-01
In-situ air sparging has evolved as an innovative technique for soil and groundwater remediation impacted with volatile organic compounds (VOCs), including chlorinated solvents. These may exist as non-aqueous phase liquid (NAPL) or dissolved in groundwater. This study assessed: (1) how air injection rate affects the mass removal of dissolved phase contamination, (2) the effect of induced groundwater flow on mass removal and air distribution during air injection, and (3) the effect of initial contaminant concentration on mass removal. Dissolved-phase chlorinated solvents can be effectively removed through the use of air sparging; however, rapid initial rates of contaminant removal are followed by a protracted period of lower removal rates, or a tailing effect. As the air flow rate increases, the rate of contaminant removal also increases, especially during the initial stages of air injection. Increased air injection rates will increase the density of air channel formation, resulting in a larger interfacial mass transfer area through which the dissolved contaminant can partition into the vapor phase. In cases of groundwater flow, increased rates of air injection lessened observed downward contaminant migration effect. The air channel network and increased air saturation reduced relative hydraulic conductivity, resulting in reduced groundwater flow and subsequent downgradient contaminant migration. Finally, when a higher initial TCE concentration was present, a slightly higher mass removal rate was observed due to higher volatilization-induced concentration gradients and subsequent diffusive flux. Once concentrations are reduced, a similar tailing effect occurs.
In situ treatment of arsenic contaminated groundwater by aquifer iron coating: Experimental Study
DOE Office of Scientific and Technical Information (OSTI.GOV)
Xie, Xianjun; Wang, Yanxin; Pi, Kunfu
In situ arsenic removal from groundwater by an iron coating method has great potential to be a cost effective and simple groundwater remediation technique, especially in rural and remote areas where groundwater is used as the main source of drinking water. The in situ arsenic removal technique was first optimized by simulating arsenic removal in various quartz sand columns under anoxic conditions., Its effectiveness was then evaluated in an actual high-arsenic groundwater environment. The mechanism of arsenic removal by the iron coating was investigated under different conditions using scanning electron microscopy (SEM)/X-ray absorption spectroscopy, an electron microprobe, and Fourier transformationmore » infrared spectroscopy. A 4-step alternative cycle aquifer iron coating method was developed. A continuous injection of 5 mmol/L FeSO4 and 2.5 mmol/L NaClO for 96 hours can create a uniform coating of crystalline goethite on the surface of quartz sand in the columns without causing clogging. At a flow rate of 0.45 cm/min of the injection reagents (vi), the time for arsenic (as Na2HAsO4) to pass through the iron-coated quartz sand column was approximately 35 hours, which was much longer than that for tracer fluorescein sodium (approximately 2 hours). The retardation factor of arsenic was 23, and its adsorption capacity was 0.11 mol As per mol Fe, leading to an excellent arsenic removal. In situ arsenic removal from groundwater in an aquifer was achieved by simultaneous injections of As (V) and Fe (II) reagents. When the arsenic content in the groundwater was 233 μg/L, the aqueous phase arsenic was completely removed with an arsenic adsorption of 0.05 mol As per mol Fe. Arsenic fixation resulted from a process of adsorption/co-precipitation, in which arsenic and iron likely formed the arsenic-bearing iron mineral phases with poor crystallinity by way of bidentate binuclear complexes. Thus, the high arsenic removal efficiency of the technique likely resulted from the expanded specific iron oxide/hydroxide surface area with poor crystallinity and from coprecipitation.« less
Cleaning of Fire Damaged Watercolor and Textiles Using Atomic Oxygen
NASA Technical Reports Server (NTRS)
Rutledge, Sharon K.; Banks, Bruce A.; Chichernea, Virgil A.; Haytas, Christy A.
2000-01-01
A noncontact technique is described that uses atomic oxygen generated under low pressure in the presence of nitrogen to remove soot from the surface of a test watercolor panel and strips of cotton, wool and silk. The process, which involves surface oxidation, permits control of the amount of surface material removed. The effectiveness of soot removal from test panels of six basic watercolors (alizarin crimson, burnt sienna, lemon yellow, yellow ochre, cerulean blue and ultramarine blue) and strips of colored cotton, wool and silk was measured using reflectance spectroscopy. The atomic oxygen removed soot effectively from the treated areas and enabled partial recovery of charred watercolors. However, overexposure can result in removal of sizing, bleaching, and weakening of the structure. With the proper precautions, atomic oxygen treatment appears to have great potential to salvage heavily smoke damaged artworks which were previously considered unrestorable.
Electromigration of Mn, Fe, Cu and Zn with citric acid in contaminated clay.
Pazos, M; Gouveia, S; Sanroman, M A; Cameselle, C
2008-07-01
Metal reactivity, speciation and solubility have an important influence in its transportation through a porous matrix by electrokinetics and, therefore, they dramatically affect the removal efficiency. This work deals with the effect of solubility and transport competition among several metals (Mn, Fe, Cu and Zn) during their transport through polluted clay. The unenhancement electrokinetic treatment results in a limited removal of the tested metals because they were retained into the kaolinite sample by the penetration of the alkaline front. Metals showed a removal degree in accordance with the solubility of the corresponding hydroxide and its formation pH. In 7 days of treatment, the removal results were: 75.6% of Mn; 68.5% of Zn, 40.6% of Cu and 14.8% of Fe. In order to avoid the negative effects of the basic front generated at the cathode, two different techniques were proposed and tested: the addition of citric acid as complexing agent to the polluted kaolinite sample and the use of citric acid to control de pH on the cathode chamber. Both techniques are based on the capability of citric acid to act as a complexing and neutralizing agent. Almost complete removal of Mn, Cu and Zn was achieved when citric acid was used (as neutralizing or complexing agent). But Fe only reached 33% of removal because it formed a negatively charged complex with citrate that retarded its transportation to the cathode.
Comparative Mirror Cleaning Study: 'A Study on Removing Particulate Contamination'
NASA Technical Reports Server (NTRS)
Houston, Karrie
2007-01-01
The cleanliness of optical surfaces is recognized as an industry-wide concern for the performance of optical devices such as mirrors and telescopes, microscopes and lenses, lasers and interferometers, and prisms and optical filters. However, no standard has been established for optical cleaning and there is no standard definition of a 'clean' optical element. This study evaluates the effectiveness of commonly used optical cleaning techniques based on wafer configuration, contamination levels, and the number and size of removed particles. It is concluded that cleaning method and exposure time play a significant factor in obtaining a high removal percentage. The detergent bath and solvent rinse method displayed an increase in effective removal percentage as the contamination exposure increased. Likewise, CO2 snow cleaning showed a relatively consistent cleaning effectiveness. The results can help ensure mission success to flight projects developed for the NASA Origins Program. Advantages and disadvantages of each of the optical cleaning methods are described.
Shin, Jaemin; Ahn, Sinyeob; Hu, Xiaoping
2015-01-01
Purpose To develop an improved and generalized technique for correcting T1-related signal fluctuations (T1 effect) in cardiac-gated functional magnetie resonance imaging (fMRI) data with flip angle estimation. Theory and Methods Spatial maps of flip angle and T1 are jointly estimated from cardiac-gated time series using a Kalman filter. These maps are subsequently used for removing the T1 effect in the presence of B1 inhomogeneity. The new technique was compared with a prior technique that uses T1 only while assuming a homogeneous flip angle of 90°. The robustness of the new technique is demonstrated with simulated and experimental data. Results Simulation results revealed that the new method led to increased temporal signal-to-noise ratio across a large range of flip angles, T1s, and stimulus onset asynchrony means compared to the T1 only approach. With the experimental data, the new approach resulted in higher average gray matter temporal signal-to-noise ratio of seven subjects (84 vs. 48). The new approach also led to a higher statistical score of activation in the lateral geniculate nucleus (P < 0.002). Conclusion The new technique is able to remove the T1 effect robustly and is a promising tool for improving the ability to map activation in fMRI, especially in subcortical regions. PMID:23390029
Safe emergency department removal of a hardened steel penile constriction ring.
Peay, Jeremy; Smithson, James; Nelson, James; Witucki, Peter
2009-10-01
Penile constriction devices are used for the enhancement of sexual performance. These devices have the potential to become incarcerated, leading to necrosis and amputation if not removed promptly. This article presents a step-by-step approach for the safe removal of a hardened steel penile constriction device using somewhat unorthodox tools found in a hospital. We present a case of an incarcerated hardened steel penile constriction ring that was not able to be removed with conventional techniques. We describe a novel technique using an electric grinder and laryngoscope blade. The technique described in this article is a valuable and relatively safe technique for the Emergency Physician to facilitate the timely removal of a hardened steel constriction device.
Thermocatalytic treatment of biomass tar model compounds via radio frequency.
Anis, Samsudin; Zainal, Z A; Bakar, M Z A
2013-05-01
A new effective RF tar thermocatalytic treatment process with low energy intensive has been proposed to remove tar from biomass gasification. Toluene and naphthalene as biomass tar model compounds were removed via both thermal and catalytic treatment over a wide temperature range from 850 °C to 1200 °C and 450 °C to 900 °C, respectively at residence time of 0-0.7 s. Thermal characteristics of the new technique are also described in this paper. This study clearly clarified that toluene was much easier to be removed than naphthalene. Soot was found as the final product of thermal treatment of the tar model and completely removed during catalytic treatment. Radical reactions generated by RF non-thermal effect improve the tar removal. The study showed that Y-zeolite has better catalytic activity compared to dolomite on toluene and naphthalene removal due to its acidic nature and large surface area, even at lower reaction temperature of about 550 °C. Copyright © 2013 Elsevier Ltd. All rights reserved.
Removal of Stationary Sinusoidal Noise from Random Vibration Signals.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnson, Brian; Cap, Jerome S.
In random vibration environments, sinusoidal line noise may appear in the vibration signal and can affect analysis of the resulting data. We studied two methods which remove stationary sine tones from random noise: a matrix inversion algorithm and a chirp-z transform algorithm. In addition, we developed new methods to determine the frequency of the tonal noise. The results show that both of the removal methods can eliminate sine tones in prefabricated random vibration data when the sine-to-random ratio is at least 0.25. For smaller ratios down to 0.02 only the matrix inversion technique can remove the tones, but the metricsmore » to evaluate its effectiveness also degrade. We also found that using fast Fourier transforms best identified the tonal noise, and determined that band-pass-filtering the signals prior to the process improved sine removal. When applied to actual vibration test data, the methods were not as effective at removing harmonic tones, which we believe to be a result of mixed-phase sinusoidal noise.« less
The Hall Technique for managing carious primary molars.
Innes, Nicola; Evans, Dafydd; Hall, Norna
2009-10-01
The Hall Technique, a method of managing carious primary molars effectively with preformed metal crowns, without the use of local anaesthesia, caries removal or tooth preparation of any kind, is described.The technique is illustrated with a case report.The evidence underpinning the technique is discussed, along with indications and contra-indications for its use, and details of where clinicians can obtain further information on the technique if they are considering using it. Research evidence has indicated that the Hall Technique is effective in managing dental caries in primary molar teeth when used by General Dental Practitioners, and is preferred by them, their child patients and the children's parents to conventional restorative methods for these teeth.
Mac A. Callaham; Arthur J. Stewart; Clara Alarcon; Sara J. McMillen
2002-01-01
Current bioremediation techniques for petroleum-contaminated soils are designed to remove contaminants as quickly and efficiently as possible, but not necessarily with postremediation soil biological quality as a primary objective. To test a simple postbioremediation technique, we added earthworms (Eisenia fetida) or wheat (Triticum aestivum...
Use of elevator instruments when luxating and extracting teeth in dentistry: clinical techniques
2017-01-01
In dentistry, elevator instruments are used to luxate teeth, and this technique imparts forces to tooth particles that sever the periodontal ligament around tooth roots inside the socket and expand alveolar bone around tooth particles. These effects can result in extraction of the tooth particles or facilitate systematic forceps extraction of the tooth particles. This article presents basic oral surgery techniques for applying elevators to luxate teeth. Determination of the optimal luxation technique requires understanding of the functions of the straight elevator and the Cryer elevator, the concept of purchase points, how the design elements of elevator working ends and tips influence the functionality of an elevator, application of forces to tooth particles, sectioning teeth at furcations, and bone removal to facilitate luxation. The effectiveness of tooth particle luxation is influenced by elevator tip shape and size, the magnitude and the vectors of forces applied to the tooth particle by the tip, and sectioning and bone removal within the operating field. Controlled extraction procedures are facilitated by a dental operating microscope or the magnification of binocular surgical loupes telescopes, combined with co-axial illumination. PMID:28770164
Grzech-Leśniak, Kinga; Matys, Jacek; Jurczyszyn, Kamil; Ziółkowski, Piotr; Dominiak, Marzena; Brugnera Junior, Aldo; Romeo, Umberto
2018-06-01
The purpose of this study was histological and thermometric examination of soft tissue de-epithelialization using digitally controlled laser handpiece (DCLH) - X-Runner. Commonly used techniques for de-epithelialization include scalpel, abrasion with diamond bur, or a combination of the two. Despite being simple, inexpensive and effective, these techniques are invasive and may produce unwanted side effects. It is important to look for alternative techniques using novel tools, which are minimally invasive and effective. 114 porcine samples sized 6 × 6 mm were collected from the attached gingiva (AG) of the alveolar process of the mandible using 15C scalpel blade. The samples were irradiated by means of Er:YAG laser (LightWalker, Fotona, Slovenia), using X-Runner and HO 2 handpieces at different parameters; 80, 100, and 140 mJ/20 Hz in time of 6 or 16 sec, respectively. The temperature was measured with a K-type thermocouple. For the histopathological analysis of efficiency of epithelium removal and thermal injury, 3 random samples were de-epithelialized with an HO 2 handpiece, and 9 random samples with an X-Runner handpiece with different parameters. For the samples irradiated with DCLH, we have used three different settings, which resulted in removing 1 to 3 layers of the soft tissue. The efficiency of epithelium removal and the rise of temperature were analyzed. DCLH has induced significantly lower temperature increase compared with HO 2 at each energy to frequency ratio. The histological examination revealed total epithelium removal when HO 2 handpiece was used at 100 and 140 mJ/20 Hz and when DCLH was used for two- and threefold lasing at 80, 100, and 140 mJ/20 Hz. Er:YAG laser with DCLH handpiece may be an efficient tool in epithelium removal without excessive thermal damage.
Rey-Dios, Roberto; Cohen-Gadol, Aaron A
2013-10-01
The supracerebellar infratentorial approach is a commonly used route in neurosurgery. It provides a narrow and deep corridor to the dorsal midbrain and pineal region. The authors describe a surgical technique to expand the operative corridor and the surgeon's working angles during this approach. Thirteen cases of patients who underwent resection of their lesions using this extended approach were reviewed. During their suboccipital craniotomy, additional bone over the transverse sinus (paramedian approach) and the confluence of the sinuses (midline approach) were removed. Two sutures (tentorial stay sutures) were anchored to the tentorium anterior to the transverse sinus and tension was applied. A video narrated by the senior author describes the details of technique. This additional bone removal and tentorial stay sutures led to gentle elevation of the tentorium and partial mobilization of the dural venous sinuses superiorly. This technique enhanced operative viewing through improved illumination and expanded working angles for microsurgical instruments while minimizing the need for fixed retractors and extensive cerebellar retraction. All patients underwent satisfactory removal of their lesions. No patient suffered from any related complication. The use of stay sutures anchored on the tentorium is a simple and effective technique that expands the surgical corridor during supracerebellar infratentorial approaches.
Removing Dams: Project-Level Policy and Scientific Research Needs (Invited)
NASA Astrophysics Data System (ADS)
Graber, B.
2010-12-01
More than 800 dams have been removed around the country, mostly “small” dams, under 25 feet in height. The total number of removals, however, is small relative to the number of deteriorating dams and the ecological impacts those structures continue to have on native riverine species and natural river function. The number of dam removal projects is increasing as aging dams continue to deteriorate and riverine species continue to decline. Practitioners and regulators need to find cost-effective project approaches that minimize short-term environmental impacts and maximize long-term benefits while keeping project costs manageable. Dam removals can be a regulatory challenge because they inherently have short-term impacts in order to achieve larger, self-sustaining, long-term benefits. These short-term impacts include sediment movement, construction access roads, and habitat conversion from lacustrine to riverine. Environmental regulations are designed to prevent degradation and have presented challenges for projects designed to benefit the environment. For example, a short-term release of sediment may exceed water quality standards for some period of time, but lead to a long-term beneficial project. Other regulatory challenges include permitting the loss of wetland area for increased native river function, or allowing the release of some level of contaminated sediment when the downstream sediment is similarly contaminated. Dam removal projects raise a range of engineering and scientific questions on effective implementation techniques such as appropriate sediment management approaches, construction equipment access approaches, invasive species management, channel/floodplain reconstruction, and active versus passive habitat rehabilitation. While practitioners have learned and refined implementation approaches over the last decade, more input is needed from researchers to help assess the effectiveness of those techniques, and to provide more effective techniques. Applied research is needed to provide management tools for practitioners on questions such as: How do we determine the quantity of sediment that is acceptable to release downstream without causing long-term harm to habitat? How can we estimate how much sediment rivers naturally carry in places where there are no sediment gauges? Will the release of coarse-grain sediment help build habitat structure downstream or will it smother habitat? What is the trajectory of habitat quality in an impoundment wetland and is it justifiable to use self-sustainability as an argument to allow a reduction in wetland area for native river habitat? Will having construction equipment working in the flowing river channel do less harm than dewatering a river channel for a longer period of time? American Rivers staff have collectively had an active involvement in more than one hundred dam removal projects. In this presentation, an American Rivers geomorphologist will pose the questions that need to be answered to reduce project-level policy challenges and allow the implementation of cost-effective dam removal projects.
Final Design for a Comprehensive Orbital Debris Management Program
NASA Technical Reports Server (NTRS)
1990-01-01
The rationale and specifics for the design of a comprehensive program for the control of orbital debris, as well as details of the various components of the overall plan, are described. The problem of orbital debris has been steadily worsening since the first successful launch in 1957. The hazards posed by orbital debris suggest the need for a progressive plan for the prevention of future debris, as well as the reduction of the current debris level. The proposed debris management plan includes debris removal systems and preventative techniques and policies. The debris removal is directed at improving the current debris environment. Because of the variance in sizes of debris, a single system cannot reasonably remove all kinds of debris. An active removal system, which deliberately retrieves targeted debris from known orbits, was determined to be effective in the disposal of debris tracked directly from earth. However, no effective system is currently available to remove the untrackable debris. The debris program is intended to protect the orbital environment from future abuses. This portion of the plan involves various environment from future abuses. This portion of the plan involves various methods and rules for future prevention of debris. The preventative techniques are protective methods that can be used in future design of payloads. The prevention policies are rules which should be employed to force the prevention of orbital debris.
Characteristics of permanganate oxidation of TCE at low reagent concentrations.
Woo, N C; Hyun, S G; Park, W W; Lee, E S; Schwartz, F W
2009-12-01
A controlled-release technique using potassium permanganate (KMnO4) has been recently developed as a long-term and semi-passive remediation scheme for dilute groundwater plumes of chlorinated solvents such as trichloroethylene (TCE) and perchloroethylene. Batch experiments were performed to evaluate TCE removal efficiencies of a low concentration of permanganate (MnO4-) solution and to estimate the optimum dose of permanganate required to remove low levels of TCE from groundwater plumes without leaving intermediate organic forms. Experimental results indicated that when the molar ratio of [MnO4-]0/[TCE]0 was about 10, 95% of the TCE in the plume was removed within less than 90 min, and about 90% of the chloride in the organic forms was converted into inorganic ions, while the TCE removal rates and the chloride conversion rates were considerably lower when the [TCE]0/ [MnO4-]0 values were lower. These data suggested that the [MnO4-]0 and the [MnO4-]0/[TCE]0 values would have strong effects on the efficiency and completeness of TCE oxidation. Further detailed investigations of the effect of [MnO4-]0 and [MnO4-]0/[TCE]0 values on the removal efficiencies and completeness of the TCE oxidation are warranted for successful application of the controlled-release KMnO4 technique in practice.
Photoacoustic removal of occlusions from blood vessels
Visuri, Steven R.; Da Silva, Luiz B.; Celliers, Peter M.; London, Richard A.; Maitland, IV, Duncan J.; Esch, Victor C.
2002-01-01
Partial or total occlusions of fluid passages within the human body are removed by positioning an array of optical fibers in the passage and directing treatment radiation pulses along the fibers, one at a time, to generate a shock wave and hydrodynamics flows that strike and emulsify the occlusions. A preferred application is the removal of blood clots (thrombin and embolic) from small cerebral vessels to reverse the effects of an ischemic stroke. The operating parameters and techniques are chosen to minimize the amount of heating of the fragile cerebral vessel walls occurring during this photo acoustic treatment. One such technique is the optical monitoring of the existence of hydrodynamics flow generating vapor bubbles when they are expected to occur and stopping the heat generating pulses propagated along an optical fiber that is not generating such bubbles.
Ultrasound guided removal of an airgun pellet from a patient's right cheek.
Grammatopoulos, E; Murtadha, L; Nair, P; Holmes, S; Makdissi, J
2008-12-01
This case report describes the use of real-time intraoperative ultrasonography to guide the removal of an airgun pellet embedded in the right cheek of a 20-year-old man. This patient had previously undergone two unsuccessful surgical attempts to have this pellet removed via blind exploration. Through the use of ultrasonography, the pellet's positional relationship throughout the procedure was accurately defined with respect to important soft and hard anatomical structures, as well as to the surgical instruments used, enabling its very efficient removal. This technique is safe, easy, cost effective and accurate, and thus minimizes post-operative morbidity and the risk of surgical complications.
NASA Astrophysics Data System (ADS)
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; Lahmann, B.; Gatu Johnson, M.; Séguin, F. H.; Sio, H.; Frenje, J. A.; Li, C. K.; Petrasso, R. D.; Park, H.-S.; Rygg, J. R.; Casey, D. T.; Bionta, R.; Turnbull, D. P.; Huntington, C. M.; Ross, J. S.; Zylstra, A. B.; Rosenberg, M. J.; Glebov, V. Yu.
2016-11-01
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.
Sutcliffe, G D; Milanese, L M; Orozco, D; Lahmann, B; Gatu Johnson, M; Séguin, F H; Sio, H; Frenje, J A; Li, C K; Petrasso, R D; Park, H-S; Rygg, J R; Casey, D T; Bionta, R; Turnbull, D P; Huntington, C M; Ross, J S; Zylstra, A B; Rosenberg, M J; Glebov, V Yu
2016-11-01
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint of the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.
Perchlorate as an emerging contaminant in soil, water and food.
Kumarathilaka, Prasanna; Oze, Christopher; Indraratne, S P; Vithanage, Meththika
2016-05-01
Perchlorate ( [Formula: see text] ) is a strong oxidizer and has gained significant attention due to its reactivity, occurrence, and persistence in surface water, groundwater, soil and food. Stable isotope techniques (i.e., ((18)O/(16)O and (17)O/(16)O) and (37)Cl/(35)Cl) facilitate the differentiation of naturally occurring perchlorate from anthropogenic perchlorate. At high enough concentrations, perchlorate can inhibit proper function of the thyroid gland. Dietary reference dose (RfD) for perchlorate exposure from both food and water is set at 0.7 μg kg(-1) body weight/day which translates to a drinking water level of 24.5 μg L(-1). Chromatographic techniques (i.e., ion chromatography and liquid chromatography mass spectrometry) can be successfully used to detect trace level of perchlorate in environmental samples. Perchlorate can be effectively removed by wide variety of remediation techniques such as bio-reduction, chemical reduction, adsorption, membrane filtration, ion exchange and electro-reduction. Bio-reduction is appropriate for large scale treatment plants whereas ion exchange is suitable for removing trace level of perchlorate in aqueous medium. The environmental occurrence of perchlorate, toxicity, analytical techniques, removal technologies are presented. Copyright © 2016 Elsevier Ltd. All rights reserved.
Venkataraghavan, Karthik; Kush, Anil; Lakshminarayana, Cs; Diwakar, Latha; Ravikumar, Puja; Patil, Shankargouda; Karthik, Sandhya
2013-08-01
The invention and application of engine driven or rotary instruments in operative treatment of carious lesions has resulted in removal of considerable toothe structure. However, with the introduction of adhesive materials for restorations, and the advent of minimal cavity design this principle has been challenged and is now considered to be too destructive to the tooth structure during caries removal. A number of techniques are available for cutting tooth tissue. The chemo mechanical method of caries removal/treatment is considered to be less painful when compared to the traditional treatment method (use of drill). The present study was carried to study the effect of an indigenously developed caries removal agent viz. Carie Care (TM) & its effectiveness as a chemo mechanical caries removal agent. How to cite this article: Venkataraghavan K, Kush A, Lakshminarayana CS, Diwakar L, Ravikumar P, Patil S, Karthik S. Chemomechanical Caries Removal: A Review & Study of an Indigenously Developed Agent (Carie Care (TM) Gel) In Children. J Int Oral Health 2013; 5(4):84-90.
Su, Z; Bai, Y H; Hou, X M
2017-02-18
To compare the effect of four different techniques on removal of vapor lock in the apical region of curved root canals. Forty simulated resin root canals with 45° curvature were prepared using WaveOne Primary, then the apical foramen were sealed with soft wax. The teeth were divided randomly into 4 groups thereafter (n=10). Contract solution was injected into the canals using a 30 G side-vented needle and scanned with cone-beam CT (CBCT) to identify the volume of the vapor lock. Four different techniques including photon-induced photoacoustic streaming (PIPS) laser-activated irrigation, gutta-percha cone technique, ultrasonic irrigation, and sonic irrigation were used to remove the vapor locks in the root canals. The residual volume of the vapor lock was identified again using CBCT scanning data. Accordingly, the reduction rates of the vapor lock were calculated. Furthermore, the initial and residual vapor lock length was calculated. The data were analyzed by using the One-way ANOVA analysis and Kruskal-Wallis H test at a significance level of P<0.05. There was no significant difference in the initial vapor lock volume (P>0.05). Residual volume of the vapor lock for PIPS laser-activated irrigation was 0 mm(3), and that for gutta-percha cone technique was (0.02±0.07) mm3, significantly lower than those of ultrasonic and sonic irrigation, the values being (0.20±0.09) mm(3) and (0.23±0.06) mm(3) (P<0.001), respectively. The reduction rates of the vapor lock of PIPS laser-activated irrigation and gutta-percha cone technique were 100.00% (100.00%, 100.00%) and 100.00% (77.66%, 100.00%), respectively, significantly higher than those of ultrasonic irrigation [70.37% (56.41%, 91.43%)] and sonic irrigation [63.54% (51.47%, 74.00%), P<0.001]. The length of the residual vapor lock for PIPS laser-activated irrigation was 0 mm, and that for gutta-percha cone technique was (0.15±0.47) mm, significantly lower than those of ultrasonic and sonic irrigation, values being (2.21±0.09) mm and (2.34±0.08) mm (P<0.001), respectively. The length of the residual vapor locks in the ultrasonic and sonic group remained approximately the same as the distance between the working tip and the apical foramen. PIPS laser activated irrigation and gutta-percha cone technique could remove the vapor lock from the apical region of curved canals effectively.
Metri, Malasiddappa; Hegde, Swaroop; Dinesh, K; Indiresha, H N; Nagaraj, Shruthi; Bhandi, Shilpa H
2015-11-01
To evaluate the effectiveness of two final irrigation techniques for the removal of precipitate formed by the interaction between sodium hypochlorite (NaOCl) and chlorhexidine (CHX). Sixty freshly extracted human maxillary incisor teeth were taken and randomly divided into three groups, containing 20 teeth each. Group 1 (control group), were irrigated with 5 ml of 2.5% NaOCl and a final flush with 5 ml of 2% chlorhexidine. Group 2 were irrigated with 5 ml of 2.5% NaOCl and 5 ml of 2% chlorhexidine followed by 5 ml of saline and agitated with F-files. Group 3 were irrigated with 5 ml of 2.5% NaOCl and 5 ml of 2% chlorhexidine followed by 5 ml of 15% citric acid and passively agitated with ultrasonics. A thin longitudinal groove was made along the buccal and lingual aspect of the root using diamond disks and split with chisel and mallet. Both halves of the split tooth will be examined under stereomicroscope. Results were tabulated and analyzed statistically using analysis of variance (ANOVA) and Mann-Whitney U test. There was a significant difference between the mean values (p < 0.05) in groups 2 and 3 compared to group 1 at each level. Passive ultrasonic irrigation is more effective than the F-file agitation technique to remove the precipitate at all three levels measured. Combination of sodium hypochlorite and chlorhexidine irrigation protocol has been practiced since from many years to achieve good results. However, it has adverse effect in the form of precipitate and which is considered to be a carcinogenic in nature, hence this precipitate should be removed.
Evaluation of triple antibiotic paste removal by different irrigation procedures.
Berkhoff, Julie A; Chen, Paul B; Teixeira, Fabricio B; Diogenes, Anibal
2014-08-01
Regenerative endodontics aims to re-establish a functional pulp-dentin complex. First, the root canal system is disinfected primarily by irrigants and medicaments. Triple antibiotic paste (TAP), a commonly used intracanal medicament, has been shown to be directly toxic to stem cells at concentrations greater than 0.1 g/mL. Thus, its complete removal is a crucial step in regenerative endodontic procedures. We hypothesized that currently used irrigation techniques do not completely remove TAP from root canal system. TAP was radiolabeled by the incorporation of I(125), and calcium hydroxide (Ultracal; Ultradent, South Jordan, UT) was radiolabeled with Ca(45). The intracanal medicaments were placed into standardized human root segments and incubated for 28 days at 37°C. Then, canals were irrigated with EndoActivator (Dentsply, Tulsa, OK), passive ultrasonic irrigation, EndoVac (SybronEndo, Coppell, TX), or a syringe/Max-i-Probe needle (Dentsply Rinn, Elgin, IL) using a standardized irrigation protocol in a closed system. Radioactivity levels (counts per minute values) were measured for each tooth before and after the irrigation protocols. Furthermore, the canals were sequentially enlarged and dentin samples collected and evaluated for radioactivity. Data were analyzed with analysis of variance and Bonferroni post hoc testing (P < .05). Approximately 88% of the TAP was retained in the root canal system regardless of the irrigation technique used (no difference among groups). Furthermore, approximately 50% of the radiolabeled TAP was present circumferentially up to 350 μm within the dentin. Conversely, up to 98% of the radiolabeled intracanal calcium hydroxide was removed, and most residual medicament was found present in the initial 50 μm of dentin. Current irrigation techniques do not effectively remove TAP from root canal systems, possibly because of its penetration and binding into dentin. However, calcium hydroxide is effectively removed with significant less residual presence. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
EEG Artifact Removal Using a Wavelet Neural Network
NASA Technical Reports Server (NTRS)
Nguyen, Hoang-Anh T.; Musson, John; Li, Jiang; McKenzie, Frederick; Zhang, Guangfan; Xu, Roger; Richey, Carl; Schnell, Tom
2011-01-01
!n this paper we developed a wavelet neural network. (WNN) algorithm for Electroencephalogram (EEG) artifact removal without electrooculographic (EOG) recordings. The algorithm combines the universal approximation characteristics of neural network and the time/frequency property of wavelet. We. compared the WNN algorithm with .the ICA technique ,and a wavelet thresholding method, which was realized by using the Stein's unbiased risk estimate (SURE) with an adaptive gradient-based optimal threshold. Experimental results on a driving test data set show that WNN can remove EEG artifacts effectively without diminishing useful EEG information even for very noisy data.
Catalytic oxidation for treatment of ECLSS and PMMS waste streams
NASA Technical Reports Server (NTRS)
Akse, James R.; Jolly, Clifford D.
1991-01-01
It is shown that catalytic oxidation is an effective technique for the removal of trace organic contaminants in a multifiltration potable processor's effluent. Essential elements of this technology are devices that deliver oxygen to the influent, and remove gaseous reaction byproducts from the effluent, via hollow-tube, gas-permeable membranes. Iodine, which poisons existing catalysis, is removed by a small deiodination bed prior to catalytic reactor entrance. The catalyst used is a mixture of Pt and Ru deposited on carbon, operating at 125-160 C and 39-90 psi pressures.
Huang, Faye; Chou, Wen-Jiun; Chen, Tien-Hsing; Chen, Ching; Hsieh, Yu-Lian; Chong, Mian-Yoon; Hung, Chi-Fa; Lin, Shu-Ching; Tsai, Hsiu-Huang; Wang, Liang-Jen
2016-08-01
Effectively managing pain is vital for the well-being and satisfaction of patients undergoing dermatologic treatments involving lasers. This study investigates the potential outcome of using muscle relaxation techniques to reduce pain among people having their tattoos removed with laser treatment. This study consists of 56 participants (mean age 18.1 ± 2.1 years) that had tattoos removed using the principle of selective photothermolysis. These participants underwent muscle relaxation before receiving the laser treatment. Their peripheral skin temperatures (PST) were measured both at the beginning and the end of the muscle relaxation period. Then, the Beck Anxiety Inventory was applied to evaluate anxiety levels. Once the laser treatment was completed, pain levels were measured using a visual analogue scale. A total of 125 person-sessions of laser treatment and psychometric assessments were performed in this study. The muscle relaxation method significantly increased the PST of the participants while reducing the levels of anxiety and pain throughout the course of the laser treatment procedure. The PST, anxiety scores, and pain scores all showed significant correlations with one another. According to the results obtained, this study proposes that muscle relaxation techniques be considered possibly auxiliary treatment options for individuals having tattoos removed through laser treatment. Additional studies with a comparison group and a larger sample size are required in the future to confirm the effectiveness of such intervention.
Stimulated emission and spontaneous loss pump-probe microscopy for background removal
NASA Astrophysics Data System (ADS)
Das, Subir; Ho, Bo-Wei; Kao, Fu-Jen
2018-02-01
In this work, we have established a double modulation lock-in detection technique using two semiconductor laser diodes in stimulated emission based pump-probe microscopy. By modulating the pump and probe beams at two different frequencies, f1 and f2, the signal is then recovered with the sum frequency, (f1+ f2), so as to minimize the leak-through noise due to the spontaneous emission caused by the pump beam. In this way, the DC background that is often attributed to the stimulated emission is effectively removed. Our technique has implemented in ATTO647N fluorescent dye which is applicable for many biological applications.
NASA Technical Reports Server (NTRS)
Pierson, W. J.
1982-01-01
The scatterometer on the National Oceanic Satellite System (NOSS) is studied by means of Monte Carlo techniques so as to determine the effect of two additional antennas for alias (or ambiguity) removal by means of an objective criteria technique and a normalized maximum likelihood estimator. Cells nominally 10 km by 10 km, 10 km by 50 km, and 50 km by 50 km are simulated for winds of 4, 8, 12 and 24 m/s and incidence angles of 29, 39, 47, and 53.5 deg for 15 deg changes in direction. The normalized maximum likelihood estimate (MLE) is correct a large part of the time, but the objective criterion technique is recommended as a reserve, and more quickly computed, procedure. Both methods for alias removal depend on the differences in the present model function at upwind and downwind. For 10 km by 10 km cells, it is found that the MLE method introduces a correlation between wind speed errors and aspect angle (wind direction) errors that can be as high as 0.8 or 0.9 and that the wind direction errors are unacceptably large, compared to those obtained for the SASS for similar assumptions.
Endodontic filling removal procedure: an ex vivo comparative study between two rotary techniques.
Vale, Mônica Sampaio do; Moreno, Melinna dos Santos; Silva, Priscila Macêdo França da; Botelho, Thereza Cristina Farias
2013-01-01
In this study, we compared the ex vivo removal capacity of two endodontic rotary techniques and determined whether there was a significant quantitative difference in residual material when comparing root thirds. Forty extracted molars were used. The palatal roots were selected, and the canals were prepared using a step-back technique and filled using a lateral condensation technique with gutta-percha points and Endofill sealer. After two weeks of storage in a 0.9% saline solution at 37 ºC in an oven, the specimens were divided into 2 groups of 20, with group 1 samples subjected to Gates-Glidden drills and group 2 samples subjected to the ProTaper retreatment System. Hedstroem files and eucalyptol solvent were used in both groups to complete the removal procedure. Then, the roots thirds were radiographed and the images were submitted to the NIH ImageJ program to measure the residual filling material in mm. Each root third was related to the total area of the root canals. The data were analyzed using Student's t test. There was a statistically significant difference between the two techniques as more filling material was removed by technique 2 (ProTaper) than technique 1 (Gates-Glidden drills, p < 0.05). The apical third had a greater amount of residual filling material than the cervical and middle thirds, and the difference was statistically significant (p < 0.05). None of the selected techniques removed all filling material, and the material was most difficult to remove from the apical third. The ProTaper files removed more material than the Gates-Glidden drills.
Remediation techniques for heavy metal-contaminated soils: Principles and applicability.
Liu, Lianwen; Li, Wei; Song, Weiping; Guo, Mingxin
2018-08-15
Globally there are over 20millionha of land contaminated by the heavy metal(loid)s As, Cd, Cr, Hg, Pb, Co, Cu, Ni, Zn, and Se, with the present soil concentrations higher than the geo-baseline or regulatory levels. In-situ and ex-situ remediation techniques have been developed to rectify the heavy metal-contaminated sites, including surface capping, encapsulation, landfilling, soil flushing, soil washing, electrokinetic extraction, stabilization, solidification, vitrification, phytoremediation, and bioremediation. These remediation techniques employ containment, extraction/removal, and immobilization mechanisms to reduce the contamination effects through physical, chemical, biological, electrical, and thermal remedy processes. These techniques demonstrate specific advantages, disadvantages, and applicability. In general, in-situ soil remediation is more cost-effective than ex-situ treatment, and contaminant removal/extraction is more favorable than immobilization and containment. Among the available soil remediation techniques, electrokinetic extraction, chemical stabilization, and phytoremediation are at the development stage, while the others have been practiced at full, field scales. Comprehensive assessment indicates that chemical stabilization serves as a temporary soil remediation technique, phytoremediation needs improvement in efficiency, surface capping and landfilling are applicable to small, serious-contamination sites, while solidification and vitrification are the last remediation option. The cost and duration of soil remediation are technique-dependent and site-specific, up to $500ton -1 soil (or $1500m -3 soil or $100m -2 land) and 15years. Treatability studies are crucial to selecting feasible techniques for a soil remediation project, with considerations of the type and degree of contamination, remediation goals, site characteristics, cost effectiveness, implementation time, and public acceptability. Copyright © 2018 Elsevier B.V. All rights reserved.
Novel application of an established technique for removing a knotted ureteric stent.
Tempest, Heidi; Turney, Ben; Kumar, Sunil
2011-04-13
This report describes a case whereby a ureteric stent became knotted during removal and lodged within the upper ureter. The authors describe a novel minimally invasive technique to remove the knotted ureteric stent using the holmium laser.
A baseline drift detrending technique for fast scan cyclic voltammetry.
DeWaele, Mark; Oh, Yoonbae; Park, Cheonho; Kang, Yu Min; Shin, Hojin; Blaha, Charles D; Bennet, Kevin E; Kim, In Young; Lee, Kendall H; Jang, Dong Pyo
2017-11-06
Fast scan cyclic voltammetry (FSCV) has been commonly used to measure extracellular neurotransmitter concentrations in the brain. Due to the unstable nature of the background currents inherent in FSCV measurements, analysis of FSCV data is limited to very short amounts of time using traditional background subtraction. In this paper, we propose the use of a zero-phase high pass filter (HPF) as the means to remove the background drift. Instead of the traditional method of low pass filtering across voltammograms to increase the signal to noise ratio, a HPF with a low cutoff frequency was applied to the temporal dataset at each voltage point to remove the background drift. As a result, the HPF utilizing cutoff frequencies between 0.001 Hz and 0.01 Hz could be effectively used to a set of FSCV data for removing the drifting patterns while preserving the temporal kinetics of the phasic dopamine response recorded in vivo. In addition, compared to a drift removal method using principal component analysis, this was found to be significantly more effective in reducing the drift (unpaired t-test p < 0.0001, t = 10.88) when applied to data collected from Tris buffer over 24 hours although a drift removal method using principal component analysis also showed the effective background drift reduction. The HPF was also applied to 5 hours of FSCV in vivo data. Electrically evoked dopamine peaks, observed in the nucleus accumbens, were clearly visible even without background subtraction. This technique provides a new, simple, and yet robust, approach to analyse FSCV data with an unstable background.
Pectus bar removal: surgical technique and strategy to avoid complications.
Park, Hyung Joo; Kim, Kyung Soo
2016-01-01
Pectus bar removal is the final stage of the procedure for minimally invasive repair of pectus excavatum. Based on our experience with one of the largest scale data, we would like to address the important issues in pectus bar removal, such as appropriate duration of bar maintenance, techniques for bar removal, and strategies to avoid complications. Between September 1999 and August 2015, we operated on 2,553 patients with pectus excavatum and carinatum using pectus bars for a minimally invasive approach. Among them, 1,821 patients (71.3%) underwent pectus bar removal as a final stage of pectus deformity repair, and their data were analyzed retrospectively to identify the outcomes and adverse effects of the pectus bar removal procedure. The mean age of the patients was 9.13 years (range, 16 months to 44 years) and the male to female ratio was 3.55. The study is approved by the Institutional Review Board (IRB), the ethical committee of Seoul St. Mary's Hospital. The IRB has exempted the informed consent from every patient in this study due to this is a retrospective chart review without revealing any patients' personal data. Our technique involved straightening of the bar in a supine position. The overall mean duration of pectus bar maintenance was 2.57 years (range, 4 months to 14 years). The mean duration was 2.02 years (range, 4 months to 7 years) for children under 12 years, 2.99 years (range, 7 months to 9 years) for teenagers aged 12-20 years, and 3.53 years (range, 3 months to 14 years) for adults over 20 years. Forty-eight patients (2.6%) underwent bar removal more than 5 years after bar insertion and 58 patients (3.2%) underwent bar removal earlier than initially planned. The most common adverse reaction after bar removal was wound seroma including infection (43 patients, 2.36%). Recurrence after bar removal occurred in nine patients (0.49%), and seven of these required redo repair (0.38%). Pectus bar removal is a safe and straightforward procedure with a low rate of complication.
Pectus bar removal: surgical technique and strategy to avoid complications
Kim, Kyung Soo
2016-01-01
Background Pectus bar removal is the final stage of the procedure for minimally invasive repair of pectus excavatum. Based on our experience with one of the largest scale data, we would like to address the important issues in pectus bar removal, such as appropriate duration of bar maintenance, techniques for bar removal, and strategies to avoid complications. Methods Between September 1999 and August 2015, we operated on 2,553 patients with pectus excavatum and carinatum using pectus bars for a minimally invasive approach. Among them, 1,821 patients (71.3%) underwent pectus bar removal as a final stage of pectus deformity repair, and their data were analyzed retrospectively to identify the outcomes and adverse effects of the pectus bar removal procedure. The mean age of the patients was 9.13 years (range, 16 months to 44 years) and the male to female ratio was 3.55. The study is approved by the Institutional Review Board (IRB), the ethical committee of Seoul St. Mary’s Hospital. The IRB has exempted the informed consent from every patient in this study due to this is a retrospective chart review without revealing any patients’ personal data. Results Our technique involved straightening of the bar in a supine position. The overall mean duration of pectus bar maintenance was 2.57 years (range, 4 months to 14 years). The mean duration was 2.02 years (range, 4 months to 7 years) for children under 12 years, 2.99 years (range, 7 months to 9 years) for teenagers aged 12–20 years, and 3.53 years (range, 3 months to 14 years) for adults over 20 years. Forty-eight patients (2.6%) underwent bar removal more than 5 years after bar insertion and 58 patients (3.2%) underwent bar removal earlier than initially planned. The most common adverse reaction after bar removal was wound seroma including infection (43 patients, 2.36%). Recurrence after bar removal occurred in nine patients (0.49%), and seven of these required redo repair (0.38%). Conclusions Pectus bar removal is a safe and straightforward procedure with a low rate of complication. PMID:29078488
Corbett, Christopher J; Love, Sandy; Moore, Anna; Burden, Faith A; Matthews, Jacqui B; Denwood, Matthew J
2014-01-24
The level of anthelmintic resistance within some cyathostomin parasite populations has increased to the level where sole reliance on anthelmintic-based control protocols is not possible. Management-based nematode control methods, including removal of faeces from pasture, are widely recommended for use in association with a reduction in anthelmintic use to reduce selection pressure for drug resistance; however, very little work has been performed to quantitatively assess the effectiveness of such methods. We analysed data obtained from 345 donkeys at The Donkey Sanctuary (Devon, UK), managed under three different pasture management techniques, to investigate the effectiveness of faeces removal in strongyle control in equids. The management groups were as follows: no removal of faeces from pasture, manual, twice-weekly removal of faeces from pasture and automatic, twice-weekly removal of faeces from pasture (using a mechanical pasture sweeper). From turn-out onto pasture in May, monthly faecal egg counts were obtained for each donkey and the dataset subjected to an auto regressive moving average model. There was little to no difference in faecal egg counts between the two methods of faecal removal; both resulted in significantly improved cyathostomin control compared to the results obtained from the donkeys that grazed pasture from which there was no faecal removal. This study represents a valuable and unique assessment of the effectiveness of the removal of equine faeces from pasture, and provides an evidence base from which to advocate twice-weekly removal of faeces from pasture as an adjunct for equid nematode control. Widespread adoption of this practice could substantially reduce anthelmintic usage, and hence reduce selection pressure for nematode resistance to the currently effective anthelmintic products.
2014-01-01
Background The level of anthelmintic resistance within some cyathostomin parasite populations has increased to the level where sole reliance on anthelmintic-based control protocols is not possible. Management-based nematode control methods, including removal of faeces from pasture, are widely recommended for use in association with a reduction in anthelmintic use to reduce selection pressure for drug resistance; however, very little work has been performed to quantitatively assess the effectiveness of such methods. Methods We analysed data obtained from 345 donkeys at The Donkey Sanctuary (Devon, UK), managed under three different pasture management techniques, to investigate the effectiveness of faeces removal in strongyle control in equids. The management groups were as follows: no removal of faeces from pasture, manual, twice-weekly removal of faeces from pasture and automatic, twice-weekly removal of faeces from pasture (using a mechanical pasture sweeper). From turn-out onto pasture in May, monthly faecal egg counts were obtained for each donkey and the dataset subjected to an auto regressive moving average model. Results There was little to no difference in faecal egg counts between the two methods of faecal removal; both resulted in significantly improved cyathostomin control compared to the results obtained from the donkeys that grazed pasture from which there was no faecal removal. Conclusions This study represents a valuable and unique assessment of the effectiveness of the removal of equine faeces from pasture, and provides an evidence base from which to advocate twice-weekly removal of faeces from pasture as an adjunct for equid nematode control. Widespread adoption of this practice could substantially reduce anthelmintic usage, and hence reduce selection pressure for nematode resistance to the currently effective anthelmintic products. PMID:24460700
Her, Ae-Young; Lim, Kyung-Hun; Shin, Eun-Seok
2018-01-27
This case study describes the successful percutaneous transcatheter retrieval of an embolized Amplatzer occluder device using the "waist capture technique" in a patient with an atrial septal defect. This technique allowed for stability of the Amplatzer device, compression of the atrial discs for easier removal, prevention of further embolization, and minimal injury to vasculature during device retrieval. This novel and effective technique can be used safely for the retrieval of Amplatzer devices in the venous system.
Novel application of an established technique for removing a knotted ureteric stent
Tempest, Heidi; Turney, Ben; Kumar, Sunil
2011-01-01
This report describes a case whereby a ureteric stent became knotted during removal and lodged within the upper ureter. The authors describe a novel minimally invasive technique to remove the knotted ureteric stent using the holmium laser. PMID:22701009
Hot Wax Sweeps Debris From Narrow Passages
NASA Technical Reports Server (NTRS)
Ricklefs, Steven K.
1990-01-01
Safe and effective technique for removal of debris and contaminants from narrow passages involves entrainment of undesired material in thermoplastic casting material. Semisolid wax slightly below melting temperature pushed along passage by pressurized nitrogen to remove debris. Devised to clean out fuel passages in main combustion chamber of Space Shuttle main engine. Also applied to narrow, intricate passages in internal-combustion-engine blocks, carburetors, injection molds, and other complicated parts.
Takahashi, Cristiane Midori; Cunha, Rodrigo Sanches; de Martin, Alexandre Sigrist; Fontana, Carlos Eduardo; Silveira, Cláudia Fernandes M; da Silveira Bueno, Carlos Eduardo
2009-11-01
Effective removal of gutta-percha in endodontic retreatment is a significant factor to ensure a favorable outcome from failed procedures. The purpose of this study was to evaluate the efficacy of a nickel-titanium rotary instrument system with or without a solvent versus stainless steel hand files for gutta-percha removal. Forty extracted human maxillary anterior teeth were prepared and filled. They were divided into 4 groups: Gates-Glidden and K-files, Gates-Glidden and K-files with chloroform, ProTaper Universal rotary retreatment system, and ProTaper Universal rotary retreatment system with chloroform. The operating time was recorded. The teeth were longitudinally sectioned and photographed. The images were analyzed and the filling remnants were quantified by using the IMAGE TOOL software. With Kruskall-Wallis test, statistical analysis showed that there was no significant difference between the techniques in regard to the amount of the endodontic filling remnants (P < .05); however, the ProTaper Universal rotary retreatment system was faster than the hand files (P < .05). All of the techniques proved helpful for the removal of endodontic filling material, and they were similar in material remaining after retreatment, but the ProTaper Universal rotary retreatment system without chloroform was faster.
Recovery of a Charred Painting Using Atomic Oxygen Treatment
NASA Technical Reports Server (NTRS)
Rutledge, Sharon K.; Banks, Bruce A.; Chichernea, Virgil A.
1999-01-01
A noncontact method is described which uses atomic oxygen to remove soot and char from the surface of a painting. The atomic oxygen was generated by the dissociation of oxygen in low pressure air using radio frequency energy. The treatment, which is an oxidation process, allows control of the amount of material to be removed. The effectiveness of char removal from half of a fire-damaged oil painting was studied using reflected light measurements from selected areas of the painting and by visual and photographic observation. The atomic oxygen was able to effectively remove char and soot from the treated half of the painting. The remaining loosely bound pigment was lightly sprayed with a mist to replace the binder and then varnish was reapplied. Caution should he used when treating an untested paint medium using atomic oxygen. A representative edge or corner should he tested first in order to determine if the process would be safe for the pigments present. As more testing occurs, a greater knowledge base will be developed as to what types of paints and varnishes can or cannot be treated using this technique. With the proper precautions, atomic oxygen treatment does appear to be a technique with great potential for allowing very charred, previously unrestorable art to be salvaged.
Watson, K; Farré, M J; Knight, N
2012-11-15
The presence of bromide (Br(-)) and iodide (I(-)) in source waters leads to the formation of brominated and iodinated disinfection by-products (DBPs), which are often more toxic than their chlorinated analogues. The increasing scarcity of water resources in Australia is leading to use of impaired and alternative water supplies with high bromide and iodide levels, which may result in the production of more brominated and iodinated DBPs. This review aims to provide a summary of research into bromide and iodide removal from drinking water sources. Bromide and iodide removal techniques have been broadly classified into three categories, namely; membrane, electrochemical and adsorptive techniques. Reverse osmosis, nanofiltration and electrodialysis membrane techniques are reviewed. The electrochemical techniques discussed are electrolysis, capacitive deionization and membrane capacitive deionization. Studies on bromide and iodide removal using adsorptive techniques including; layered double hydroxides, impregnated activated carbons, carbon aerogels, ion exchange resins, aluminium coagulation and soils are also assessed. Halide removal techniques have been compared, and areas for future research have been identified. Copyright © 2012 Elsevier Ltd. All rights reserved.
Effect of missing data on multitask prediction methods.
de la Vega de León, Antonio; Chen, Beining; Gillet, Valerie J
2018-05-22
There has been a growing interest in multitask prediction in chemoinformatics, helped by the increasing use of deep neural networks in this field. This technique is applied to multitarget data sets, where compounds have been tested against different targets, with the aim of developing models to predict a profile of biological activities for a given compound. However, multitarget data sets tend to be sparse; i.e., not all compound-target combinations have experimental values. There has been little research on the effect of missing data on the performance of multitask methods. We have used two complete data sets to simulate sparseness by removing data from the training set. Different models to remove the data were compared. These sparse sets were used to train two different multitask methods, deep neural networks and Macau, which is a Bayesian probabilistic matrix factorization technique. Results from both methods were remarkably similar and showed that the performance decrease because of missing data is at first small before accelerating after large amounts of data are removed. This work provides a first approximation to assess how much data is required to produce good performance in multitask prediction exercises.
Decontamination of soils containing PAHs by electroremediation: a review.
Pazos, M; Rosales, E; Alcántara, T; Gómez, J; Sanromán, M A
2010-05-15
During the last years, the anthropogenic sources have contributed to organic compound penetration into the environment. One large group of persistent and toxic contaminants is the hydrophobic organic contaminants. Among them, polycyclic aromatic hydrocarbons (PAHs) have been recognized as a representative group of these pollutants with low solubility. In this paper, it is showed the electroremediation of soil contaminated with PAHs as an alternative, to organic compound removal. This technique, mainly used for heavy metal extraction, applies the electric current to promote the movement of contaminants. Nowadays the application of this technique alone or combined with other techniques as for example Fenton or bioremediation is taking fine results to PAHs removal. Although the PAHs soil decontamination by means of the electric field is in an initial stage, many researchers have demonstrated the treatment effectiveness. This paper describes the foremost principles to carry out the electroremediation of soils contaminated with PAHs, just like the different alternatives to improve the electroremediation of PAHs and also the new methodologies of PAHs removal by using hybrid technologies. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Topical medication instillation techniques for glaucoma
Xu, Li; Wang, Xuemei; Wu, Meijing
2017-01-01
Background Glaucoma is a leading cause of irreversible blindness worldwide and the second most common cause of blindness after cataracts. The primary treatment for glaucoma aims to lower intraocular pressure (IOP) with the use of topical medicines. Topical medication instillation techniques, such as eyelid closure and nasolacrimal occlusion when instilling drops, have been proposed as potential methods to increase ocular absorption and decrease systemic absorption of the drops. Objectives To investigate the effectiveness of topical medication instillation techniques compared with usual care or another method of instillation of topical medication in the management of glaucoma or ocular hypertension. Search methods We searched the Cochrane Central Register of Controlled Trials (CENTRAL) (which contains the Cochrane Eyes and Vision Trials Register) (2016, Issue 12), MEDLINE Ovid (1946 to 8 December 2016), Embase Ovid (1947 to 8 December 2016), PubMed (1948 to 8 December 2016), LILACS (Latin American and Caribbean Health Sciences Literature Database) (1982 to 8 December 2016), International Pharmaceutical Abstracts Database (1970 to 8 December 2016), the metaRegister of Controlled Trials (mRCT) (www.controlled-trials.com) (last searched 13 May 2013), ClinicalTrials.gov (www.clinicaltrials.gov) (searched 8 December 2016) and the WHO International Clinical Trials Registry Platform (ICTRP) (www.who.int/ictrp/search/en) (searched 8 December 2016). We did not use any date or language restrictions in the electronic searches for trials. Selection criteria We included randomized controlled trials which had compared any topical medication instillation technique with usual care or a different method of instillation of topical medication. Data collection and analysis Two review authors independently screened records from the searches for eligibility, assessed the risk of bias, and extracted data. We followed methods recommended by Cochrane. Main results We identified two trials (122 eyes of 61 participants) that had evaluated a topical medication instillation technique. We also identified two ongoing trials. Both included trials used a within-person design and administered prostaglandin monotherapy for glaucoma or ocular hypertension. Because the trials evaluated different instillation techniques and assessed different outcomes, we performed no meta-analysis. One trial, conducted in the US, evaluated the effect of eyelid closure (one and three minutes) versus no eyelid closure on lowering IOP. At one to two weeks' follow-up, reduction in IOP was similar in the eyelid closure group and the no eyelid closure group (mean difference (MD) -0.33 mmHg, 95% confidence interval (CI) -0.8 to 1.5; 51 participants; moderate-certainty evidence). The second trial, conducted in Italy, evaluated the effect of using an absorbent cloth to wipe excess fluid after instillation (fluid removal) versus not using an absorbent cloth (no removal) on reducing dermatologic adverse events. At four months' follow-up, eyelashes were shorter among eyes in the fluid removal group compared with the no fluid removal group (MD -1.70 mm, 95% CI -3.46 to 0.06; 10 participants; low-certainty evidence). Fewer eyes showed skin hyperpigmentation in the eyelid region towards the nose in the fluid removal group compared with the no removal group (RR 0.07, 95% CI 0.01 to 0.84; 10 participants; low-certainty evidence); however, the difference was uncertain in the eyelid region towards the temples (RR 0.44, 95% CI 0.07 to 2.66; 10 participants; low-certainty evidence). The effect hypertrichosis (excessive hair growth) was uncertain between groups (RR 1.00, 95% CI 0.17 to 5.98; 10 participants; low-certainty evidence). Neither trial reported other outcomes specified for this review, including the proportion of participants with IOP less than 21 mmHg; participant-reported outcomes related to the ease, convenience, and comfort of instillation techniques; physiologic measurements of systemic absorption; escalation of therapy; mean change in visual fields; optic nerve progression; mean change in best-corrected visual acuity; proportion in whom glaucoma developed; quality of life outcomes; or cost-effectiveness outcomes. Neither trial reported data at follow-up times of more than four months. Authors' conclusions Evidence to evaluate the effectiveness of topical medication instillation techniques for treatment of glaucoma is lacking. It is unclear what, if any, effects instillation techniques have on topical medical therapy for glaucoma. PMID:28218404
Swami, Saurabh; Muzammil, Raunaq; Saha, Supradip; Shabeer, Ahammed; Oulkar, Dasharath; Banerjee, Kaushik; Singh, Shashi Bala
2016-05-01
Ozonated water dip technique was evaluated for the detoxification of six pesticides, i.e., chlorpyrifos, cypermethrin, azoxystrobin, hexaconazole, methyl parathion, and chlorothalonil from apple fruits. Results revealed that ozonation was better than washing alone. Ozonation for 15 min decreased residues of the test pesticides in the range of from 26.91 to 73.58%, while ozonation for 30 min could remove the pesticide residues by 39.39-95.14 % compared to 19.05-72.80 % by washing. Cypermethrin was the least removed pesticide by washing as well as by ozonation. Chlorothalonil, chlorpyrifos, and azoxystrobin were removed up to 71.45-95.14 % in a 30-min ozonation period. In case of methyl parathion removal, no extra advantage could be obtained by ozonation. The HPLC analysis indicated that ozonation also affected adversely the ascorbic acid and cyanidin-3-glucoside content of apples. However, 11 polyphenols studied showed a mixed trend. Gallic acid, 3,4-dihydroxybenzoic acid, catechin, epicatechin, p-coumaric acid, quercetin-3-O-glucoside, quercetin, and kaempferol were found to decrease while syringic acid, rutin, and resveratrol were found to increase in 30-min ozonation.
NASA Astrophysics Data System (ADS)
Ahmad, Mohd Azmier; Afandi, Nur Syahidah; Bello, Olugbenga Solomon
2017-05-01
This study investigates the adsorptive removal of malachite green (MG) dye from aqueous solutions using chemically modified lime-peel-based activated carbon (LPAC). The adsorbent prepared was characterized using FTIR, SEM, Proximate analysis and BET techniques, respectively. Central composite design (CCD) in response surface methodology (RSM) was used to optimize the adsorption process. The effects of three variables: activation temperature, activation time and chemical impregnation ratio (IR) using KOH and their effects on percentage of dye removal and LPAC yield were investigated. Based on CCD design, quadratic models and two factor interactions (2FI) were developed correlating the adsorption variables to the two responses. Analysis of variance (ANOVA) was used to judge the adequacy of the model. The optimum conditions of MG dye removal using LPAC are: activation temperature (796 °C), activation time (1.0 h) and impregnation ratio (2.6), respectively. The percentage of MG dye removal obtained was 94.68 % resulting in 17.88 % LPAC yield. The percentage of error between predicted and experimental results for the removal of MG dye is 0.4 %. Model prediction was in good agreement with experimental results and LPAC was found to be effective in removing MG dye from aqueous solution.
Laparoscopic subtotal colectomy with transrectal extraction of the colon and ileorectal anastomosis.
Awad, Ziad T
2012-03-01
Despite the growing acceptance of laparoscopic colon surgery, an abdominal incision is needed to remove the specimen and perform an anastomosis. Five trocars (one 12 mm and four 5 mm) were used. The video describes the technique of performing laparoscopic subtotal colectomy, laparoscopic cholecystectomy, transrectal removal of the gallbladder and the entire colon, and intracorporeal stapled ileorectal anastomosis in a 27-year-old female with colonic inertia and biliary dyskinesia. There were no intraoperative complications. The operating time was 180 min. Blood loss was 10 cc. The patient was discharged home on postoperative day 4. Laparoscopic subtotal colectomy with transrectal removal of the colon is a safe and effective procedure that can be added to the armamentarium of surgeons performing laparoscopic colon surgery. This technique may provide both an attractive way to reduce abdominal wall morbidity and a bridge to NOTES colon surgery.
Winston, Ryan J; Al-Rubaei, Ahmed M; Blecken, Godecke T; Viklander, Maria; Hunt, William F
2016-03-15
The surface infiltration rates (SIR) of permeable pavements decline with time as sediment and debris clog pore spaces. Effective maintenance techniques are needed to ensure the hydraulic functionality and water quality benefits of this stormwater control. Eight different small-scale and full-scale maintenance techniques aimed at recovering pavement permeability were evaluated at ten different permeable pavement sites in the USA and Sweden. Maintenance techniques included manual removal of the upper 2 cm of fill material, mechanical street sweeping, regenerative-air street sweeping, vacuum street sweeping, hand-held vacuuming, high pressure washing, and milling of porous asphalt. The removal of the upper 2 cm of clogging material did not significantly improve the SIR of concrete grid paves (CGP) and permeable interlocking concrete pavers (PICP) due to the inclusion of fines in the joint and bedding stone during construction, suggesting routine maintenance cannot overcome improper construction. For porous asphalt maintenance, industrial hand-held vacuum cleaning, pressure washing, and milling were increasingly successful at recovering the SIR. Milling to a depth of 2.5 cm nearly restored the SIR for a 21-year old porous asphalt pavement to like-new conditions. For PICP, street sweepers employing suction were shown to be preferable to mechanical sweepers; additionally, maintenance efforts may become more intensive over time to maintain a threshold SIR, as maintenance was not 100% effective at removing clogging material. Copyright © 2015 Elsevier Ltd. All rights reserved.
Robust detrending, rereferencing, outlier detection, and inpainting for multichannel data.
de Cheveigné, Alain; Arzounian, Dorothée
2018-05-15
Electroencephalography (EEG), magnetoencephalography (MEG) and related techniques are prone to glitches, slow drift, steps, etc., that contaminate the data and interfere with the analysis and interpretation. These artifacts are usually addressed in a preprocessing phase that attempts to remove them or minimize their impact. This paper offers a set of useful techniques for this purpose: robust detrending, robust rereferencing, outlier detection, data interpolation (inpainting), step removal, and filter ringing artifact removal. These techniques provide a less wasteful alternative to discarding corrupted trials or channels, and they are relatively immune to artifacts that disrupt alternative approaches such as filtering. Robust detrending allows slow drifts and common mode signals to be factored out while avoiding the deleterious effects of glitches. Robust rereferencing reduces the impact of artifacts on the reference. Inpainting allows corrupt data to be interpolated from intact parts based on the correlation structure estimated over the intact parts. Outlier detection allows the corrupt parts to be identified. Step removal fixes the high-amplitude flux jump artifacts that are common with some MEG systems. Ringing removal allows the ringing response of the antialiasing filter to glitches (steps, pulses) to be suppressed. The performance of the methods is illustrated and evaluated using synthetic data and data from real EEG and MEG systems. These methods, which are mainly automatic and require little tuning, can greatly improve the quality of the data. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.
Arsenic removal by electrocoagulation process: Recent trends and removal mechanism.
Nidheesh, P V; Singh, T S Anantha
2017-08-01
Arsenic contamination in drinking water is a major issue in the present world. Arsenicosis is the disease caused by the regular consumption of arsenic contaminated water, even at a lesser contaminated level. The number of arsenicosis patients is increasing day-by-day. Decontamination of arsenic from the water medium is the only one way to regulate this and the arsenic removal can be fulfilled by water treatment methods based on separation techniques. Electrocoagulation (EC) process is a promising technology for the effective removal of arsenic from aqueous solution. The present review article analyzes the performance of the EC process for arsenic removal. Electrocoagulation using various sacrificial metal anodes such as aluminium, iron, magnesium, etc. is found to be very effective for arsenic decontamination. The performances of each anode are described in detail. A special focus has been made on the mechanism behind the arsenite and arsenate removal by EC process. Main trends in the disposal methods of sludge containing arsenic are also included. Comparison of arsenic decontamination efficiencies of chemical coagulation and EC is also reported. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kato, Kazuyoshi; Katsuda, Takahiro; Takeshima, Nobuhiro
2016-03-01
Upper abdominal spreading of advanced-stage ovarian cancer often involves the diaphragm. In addition, bulky diaphragmatic tumors occasionally infiltrate the liver. Here, we describe our early experiences with a ventral liver mobilization technique to remove diaphragmatic tumors with liver involvement. Two patients with primary ovarian cancer and 1 patient with recurrent ovarian cancer underwent en bloc resections of a diaphragmatic tumor together with the full-thickness diaphragm and the liver tissue using a ventral liver mobilization technique. The surgical technique involved a full-thickness division of the diaphragm at the central tendon and a ventral mobilization of the right lobe of the liver, with entry into the pleural cavity. During the parenchymal transection of the liver, the posterior area of the right lobe of the liver was pressed using the surgeon's hand to reduce bleeding from the resection surface. After the completion of the en bloc resection, the diaphragmatic opening was closed using running sutures. All the diaphragmatic tumors were completely removed without severe bleeding in the current series. No intraoperative or postoperative complications occurred. Diaphragmatic tumors with involvement of the liver can be safely and effectively removed using a ventral liver mobilization technique. This surgical procedure may be suitable for the management of bulky diaphragmatic tumors in select patients. Copyright © 2016 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Miyashita, Naoya; Behaghel, Benoît; Guillemoles, Jean-François; Okada, Yoshitaka
2018-07-01
This work focuses on the characterization of GaInNAsSb solar cells whose substrates are removed via the epitaxial lift-off (ELO) technique. As a result of the substrate removal, increases in the photocurrent and the interference feature were clearly observed. This is clear evidence of the light-confinement effect, whereby some of the unabsorbed photons at the rear metal contact were reflected back towards the front side of the ELO thin-film cell. We successfully demonstrated that the ELO technique can be applied for the GaInNAsSb cell, and the light management should add flexibility in designing the cell structures.
Use of an Atmospheric Atomic Oxygen Beam for Restoration of Defaced Paintings
NASA Technical Reports Server (NTRS)
Banks, Bruce A.; Rutledge, Sharon K.; Karla, Margaret; Norris, Mary Jo; Real, William A.; Haytas, Christy A.
1999-01-01
An atmospheric atomic oxygen beam has been found to be effective in removing organic materials through oxidation that are typical of graffiti or other contaminant defacements which may occur to the surfaces of paintings. The technique, developed by the National Aeronautics and Space Administration, is portable and was successfully used at the Carnegie Museum of Art to remove a lipstick smudge from the surface of porous paint on the Andy Warhol painting "Bathtub." This process was also evaluated for suitability to remove felt tip and ball point ink graffiti from paper, gesso on canvas and cotton canvas.
Symptomatic iliofemoral deep venous thrombosis treated with hybrid operative thrombectomy.
Rodríguez, Limael E; Aponte-Rivera, Francisco; Figueroa-Vicente, Ricardo; Bolanos-Avila, Guillermo E; Martínez-Trabal, Jorge L
2015-10-01
During the past 15 years, strategies that promote immediate and complete thrombus removal have gained popularity for the treatment of acute-onset iliofemoral deep venous thrombosis. In this case report, we describe a novel operative approach to venous thrombus removal known as hybrid operative thrombectomy. The technique employs a direct inguinal approach with concomitant retrograde advancement of a balloon catheter by femoral venotomy. Moreover, it provides effective thrombus removal through a single incision, with or without stent placement, and has the advantage of a completion venogram. Copyright © 2015 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.
Evaluation of current techniques for isolation of chars as natural adsorbents
Chun, Y.; Sheng, G.; Chiou, C.T.
2004-01-01
Chars in soils or sediments may potentially influence the soil/sediment sorption behavior. Current techniques for the isolation of black carbon including chars rely often on acid demineralization, base extraction, and chemical oxidation to remove salts and minerals, humic acid, and refractory kerogen, respectively. Little is known about the potential effects of these chemical processes on the char surface and adsorptive properties. This study examined the effects of acid demineralization, base extraction, and acidic Cr2O72- oxidation on the surface areas, surface acidity, and benzene adsorption characteristics of laboratory-produced pinewood and wheat-residue chars, pure or mixed with soils, and a commercial activated carbon. Demineralization resulted in a small reduction in the char surface area, whereas base extraction showed no obvious effect. Neither demineralization nor base extraction caused an appreciable variation in benzene adsorption and presumably the char surface properties. By contrast, the Cr2O 72- oxidation caused a >31% reduction in char surface area. The Boehm titration, supplemented by FTIR spectra, indicated that the surface acidity of oxidized chars increased by a factor between 2.3 and 12 compared to nonoxidized chars. Benzene adsorption with the oxidized chars was lower than that with the non-oxidized chars by a factor of >8.9; both the decrease in char surface area and the increase in char surface acidity contributed to the reduction in char adsorptive power. Although the Cr 2O72- oxidation effectively removes resistant kerogen, it is not well suited for the isolation of chars as contaminant adsorbents because of its destructive nature. Alternative nondestructive techniques that preserve the char surface properties and effectively remove kerogen must be sought.
Fabrication of ф 160 mm convex hyperbolic mirror for remote sensing instrument
NASA Astrophysics Data System (ADS)
Kuo, Ching-Hsiang; Yu, Zong-Ru; Ho, Cheng-Fang; Hsu, Wei-Yao; Chen, Fong-Zhi
2012-10-01
In this study, efficient polishing processes with inspection procedures for a large convex hyperbolic mirror of Cassegrain optical system are presented. The polishing process combines the techniques of conventional lapping and CNC polishing. We apply the conventional spherical lapping process to quickly remove the sub-surface damage (SSD) layer caused by grinding process and to get the accurate radius of best-fit sphere (BFS) of aspheric surface with fine surface texture simultaneously. Thus the removed material for aspherization process can be minimized and the polishing time for SSD removal can also be reduced substantially. The inspection procedure was carried out by using phase shift interferometer with CGH and stitching technique. To acquire the real surface form error of each sub aperture, the wavefront errors of the reference flat and CGH flat due to gravity effect of the vertical setup are calibrated in advance. Subsequently, we stitch 10 calibrated sub-aperture surface form errors to establish the whole irregularity of the mirror in 160 mm diameter for correction polishing. The final result of the In this study, efficient polishing processes with inspection procedures for a large convex hyperbolic mirror of Cassegrain optical system are presented. The polishing process combines the techniques of conventional lapping and CNC polishing. We apply the conventional spherical lapping process to quickly remove the sub-surface damage (SSD) layer caused by grinding process and to get the accurate radius of best-fit sphere (BFS) of aspheric surface with fine surface texture simultaneously. Thus the removed material for aspherization process can be minimized and the polishing time for SSD removal can also be reduced substantially. The inspection procedure was carried out by using phase shift interferometer with CGH and stitching technique. To acquire the real surface form error of each sub aperture, the wavefront errors of the reference flat and CGH flat due to gravity effect of the vertical setup are calibrated in advance. Subsequently, we stitch 10 calibrated sub-aperture surface form errors to establish the whole irregularity of the mirror in 160 mm diameter for correction polishing. The final result of the Fabrication of ф160 mm Convex Hyperbolic Mirror for Remote Sensing Instrument160 mm convex hyperbolic mirror is 0.15 μm PV and 17.9 nm RMS.160 mm convex hyperbolic mirror is 0.15 μm PV and 17.9 nm RMS.
Data of furfural adsorption on nano zero valent iron (NZVI) synthesized from Nettle extract.
Fazlzadeh, Mehdi; Ansarizadeh, Mohammad; Leili, Mostafa
2018-02-01
Among various water and wastewater treatment methods, adsorption techniques are widely used to remove certain classes of pollutants due to its unique features. Thus, the aim of this data article is to synthesize zero valent iron nanoparticles (NZVI) from Nettle leaf extract by green synthesis method as an environmentally friendly technique, and to evaluate it's efficiency in the removal of furfural from aqueous solutions. The data of possible adsorption mechanism and isotherm of furfural on the synthesized adsorbent are depicted in this data article. The data acquired showed that the adsorption trend follows the pseudo-second order kinetic model and that the Langmuir isotherm was suitable for correlation of equilibrium data with the maximum adsorption capacity of 454.4 mg/g. The information of initial furfural concentration, pH, adsorbent dosage and contact time effects on the removal efficiency are presented. Considering the findings data, the developed nanoparticle from Nettle leaf extract, as a low cost adsorbent, could be considered as promising adsorbent for furfural and probably similar organic pollutants removal from aqueous solutions.
Park, Su Bum; Kim, Hyung Wook; Kang, Dae Hwan; Choi, Cheol Woong; Yoon, Ki Tae; Cho, Mong; Song, Byeong Jun
2013-01-01
AIM: To investigate the usefulness of a guide wire and triple lumen needle knife for removing stones in Billroth II (B-II) gastrectomy patients. METHODS: Endoscopic sphincterotomy in patients with B-II gastrectomy is challenging. We used a new guide wire technique involving sphincterotomy by triple lumen needle knife through a forward-viewing endoscopy. This technique was performed in nine patients between August 2010 and June 2012. Sphincterotomy as described above was performed. Adequate sphincterotomy, successful stone removal, and complications were investigated prospectively. RESULTS: Sphincterotomy by triple lumen needle knife using guide wire was successful in all nine patients. Sphincterotomy started towards the 4-5 o’clock direction and continued to the upper margin of the papillary roof. Complete stone removal in one session was achieved in all patients. There were no procedure related complications, such as bleeding, pancreatitis, or perforation. CONCLUSION: In patients with B-II gastrectomy, guide wire using sphincterotomy by triple lumen needle knife through a forward-viewing endoscopy seems to be an effective and safe procedure for the removal of common bile duct stones. PMID:24409069
Jiang, Shan; Zou, Ting; Li, Dongxia; Chang, Jeffery W W; Huang, Xiaojing; Zhang, Chengfei
2016-01-01
This study aimed to assess the effectiveness of sonic, ultrasonic and laser [photon-induced photoacoustic streaming (PIPS)] irrigation activation in removing filling remnants from oval root canals after standard canal retreatment procedures with the ProTaper universal rotary retreatment system. Twenty-eight maxillary first premolars were instrumented with ProTaper NiTi rotary instruments and obturated with gutta-percha and AH Plus sealer using the continuous wave of condensation technique. After storage at 37°C and 100% humidity for 1 week, the specimens were retreated with the ProTaper universal retreatment system for the removal of filling material. Teeth were then randomly assigned into four groups (n = 7): group 1, positive control; group 2, retreated with sonic irrigation; group 3, retreated with ultrasonic irrigation; and group 4, retreated with laser irradiation. The specimens were scanned using micro-CT before instrumentation, after obturation and mechanical retreatment, and after additional activation procedures. The percentage volume of the filling remnants was measured. Specimens were split longitudinally after micro-CT scan, canal walls were examined using scanning electron microscopy (SEM), and the amount of residual filling material was scored. The filling materials' removal efficacy in the three experimental groups was higher than that of the control group (p < 0.05), whereas filling materials ranging from 1.46 ± 0.30 to 2.21 ± 0.46 mm(3) remained in the canal in all three experimental groups. Additionally, there was a significantly greater reduction in the amount of filling remnants in the PIPS group than in the sonic and ultrasonic groups (both p < 0.05), and significantly greater reduction in the ultrasonic group than the sonic group (p < 0.05). Activation of NaOCl with PIPS showed significantly better performance than sonic and ultrasonic techniques in removing the filling remnants following mechanical retreatment of oval root canals. The ultrasonic technique also performed better than the sonic technique. However, none of the additional activation procedures was able to completely eliminate the filling remnants.
Hasegawa, Teruaki; Kurose, Yohei; Tanaka, Yasuo
2017-10-01
The efficacy of advanced treatment of swine wastewater using thermally polymerized, modified amorphous silica and hydrated lime (M-CSH-lime) for color and phosphorus removal and sulfur for nitrogen removal was examined with a demonstration-scale treatment plant. The color removal rate was approximately 78% at M-CSH-lime addition rates of > 0.055 wt/v%. The PO43--P removal rate exceeded 99.9% with > 0.023 wt/v%. pH of the effluent from the M-CSH-lime reactor increased with the addition rate till a maximum value of 12.7, which was effective in disinfection. The recovered M-CSH-lime would be suitable as a phosphorus fertilizer because the total P 2 O 5 content was approximately 10%. The nitrogen oxide (NOx-N) removal rate by sulfur denitrification increased to approximately 80% when the NOx-N loading rate was around 0.1 kg-N/ton-S/day. It was suggested that the combination of the two processes would be effective in the advanced treatment of swine wastewater. © 2017 Japanese Society of Animal Science.
Xue, Juan Qin; Liu, Ni Na; Li, Guo Ping; Dang, Long Tao
To solve the disposal problem of cyanide wastewater, removal of cyanide from wastewater using a water-in-oil emulsion type of emulsion liquid membrane (ELM) was studied in this work. Specifically, the effects of surfactant Span-80, carrier trioctylamine (TOA), stripping agent NaOH solution and the emulsion-to-external-phase-volume ratio on removal of cyanide were investigated. Removal of total cyanide was determined using the silver nitrate titration method. Regression analysis and optimization of the conditions were conducted using the Design-Expert software and response surface methodology (RSM). The actual cyanide removals and the removals predicted using RSM analysis were in close agreement, and the optimal conditions were determined to be as follows: the volume fraction of Span-80, 4% (v/v); the volume fraction of TOA, 4% (v/v); the concentration of NaOH, 1% (w/v); and the emulsion-to-external-phase volume ratio, 1:7. Under the optimum conditions, the removal of total cyanide was 95.07%, and the RSM predicted removal was 94.90%, with a small exception. The treatment of cyanide wastewater using an ELM is an effective technique for application in industry.
ERIC Educational Resources Information Center
Rillo, Thomas J.
1974-01-01
Discusses damages of oil tanker spillage to the marine organisms and scientists' research in oil pollution removal techniques. Included is a list of learning activities concerning the causes and effects of oil pollution and methods of solving the problem. (CC)
String Technique for Anterior Orbital Fish Hook Removal.
Starr, Matthew R; Choi, Michael B; Mahr, Michael A; Mettu, Pradeep; Patterson, David F
2018-06-13
Removing fish hooks is a common procedure performed by many emergency department providers. There are several techniques that are commonly employed to aid in successful removal. However, when a fish hook becomes embedded within the orbit, there are limited options as to avoid damaging vital surrounding structures. The authors report the removal of a fish hook within the anterior orbit using the string technique in a 25-year-old patient. The procedure was performed under general anesthesia with the aid of size 5 polyglactin suture wrapped around the hook. The procedure itself took less than 10 seconds and was successful in swiftly and safely removing the hook without damaging surrounding orbital structures. The patient recovered well without any permanent sequelae.
Oloibiri, Violet; Ufomba, Innocent; Chys, Michael; Audenaert, Wim; Demeestere, Kristof; Van Hulle, Stijn W H
2015-01-01
A major concern for landfilling facilities is the treatment of their leachate. To optimize organic matter removal from this leachate, the combination of two or more techniques is preferred in order to meet stringent effluent standards. In our study, coagulation-flocculation and ozonation are compared as pre- treatment steps for stabilized landfill leachate prior to granular activated carbon (GAC) adsorption. The efficiency of the pre treatment techniques is evaluated using COD and UVA254 measurements. For coagulation- flocculation, different chemicals are compared and optimal dosages are determined. After this, iron (III) chloride is selected for subsequent adsorption studies due to its high percentage of COD and UVA254 removal and good sludge settle-ability. Our finding show that ozonation as a single treatment is effective in reducing COD in landfill leachate by 66% compared to coagulation flocculation (33%). Meanwhile, coagulation performs better in UVA254 reduction than ozonation. Subsequent GAC adsorption of ozonated effluent, coagulated effluent and untreated leachate resulted in 77%, 53% and 8% total COD removal respectively (after 6 bed volumes). The effect of the pre-treatment techniques on GAC adsorption properties is evaluated experimentally and mathematically using Thomas and Yoon-Nelson models. Mathematical modelling of the experimental GAC adsorption data shows that ozonation increases the adsorption capacity and break through time with a factor of 2.5 compared to coagulation-flocculation.
O'Regan, Barry; Devine, Maria; Bhopal, Sats
2013-01-01
Stable anatomical fracture reduction and segment control before miniplate fixation can be difficult to achieve in comminuted midfacial fractures. Fracture mobilization and reduction methods include Gillies elevation, malar hook, and Dingman elevators. No single method is used universally. Disadvantages include imprecise segment alignment and poor segment stability/control. We have employed screw-wire osteo-traction (SWOT) to address this problem. A literature review revealed two published reports. The aims were to evaluate the SWOT technique effectiveness as a fracture reduction method and to examine rates of revision fixation and plate removal. We recruited 40 consecutive patients requiring open reduction and internal fixation of multisegment midfacial fractures (2009–2012) and employed miniplate osteosynthesis in all patients. SWOT was used as a default reduction method in all patients. The rates of successful fracture reduction achieved by SWOT alone or in combination and of revision fixation and plate removal, were used as outcome indices of the reduction method effectiveness. The SWOT technique achieved satisfactory anatomical reduction in 27/40 patients when used alone. Other reduction methods were also used in 13/40 patients. No patient required revision fixation and three patients required late plate removal. SWOT can be used across the midface fracture pattern in conjunction with other methods or as a sole reduction method before miniplate fixation. PMID:24436763
Effects of surface polishing on the microstrain behavior of telescope mirror materials
NASA Technical Reports Server (NTRS)
Eul, W. A.; Woods, W. W.
1973-01-01
Rough ground silicic mirror substrate materials were found in previous investigations to exhibit significant surface yield. This effect was removed by surface etching, a procedure not normally employed in the finishing of optical telescope mirrors. The effects of fine grinding and polishing techniques as well as graded etching are investigated. Torsional shear measurements of yield strain versus stress are made on four candidate mirror substrate materials: polycrystalline silicon, ULE silica 7971, CER-VIT 101, and fused silica 7940. Commonly employed fine grinding and polishing practices are shown to remove a major portion of the surface yield found in rough ground mirror substrate materials.
"Push back" technique: A simple method to remove broken drill bit from the proximal femur.
Chouhan, Devendra K; Sharma, Siddhartha
2015-11-18
Broken drill bits can be difficult to remove from the proximal femur and may necessitate additional surgical exploration or special instrumentation. We present a simple technique to remove a broken drill bit that does not require any special instrumentation and can be accomplished through the existing incision. This technique is useful for those cases where the length of the broken drill bit is greater than the diameter of the bone.
Techniques for noise removal and registration of TIMS data
Hummer-Miller, S.
1990-01-01
Extracting subtle differences from highly correlated thermal infrared aircraft data is possible with appropriate noise filters, constructed and applied in the spatial frequency domain. This paper discusses a heuristic approach to designing noise filters for removing high- and low-spatial frequency striping and banding. Techniques for registering thermal infrared aircraft data to a topographic base using Thematic Mapper data are presented. The noise removal and registration techniques are applied to TIMS thermal infrared aircraft data. -Author
Sutcliffe, G. D.; Milanese, L. M.; Orozco, D.; ...
2016-08-05
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sutcliffe, G. D., E-mail: gdsut@mit.edu; Milanese, L. M.; Orozco, D.
2016-11-15
CR-39 detectors are used routinely in inertial confinement fusion (ICF) experiments as a part of nuclear diagnostics. CR-39 is filtered to stop fast ablator ions which have been accelerated from an ICF implosion due to electric fields caused by laser-plasma interactions. In some experiments, the filtering is insufficient to block these ions and the fusion-product signal tracks are lost in the large background of accelerated ion tracks. A technique for recovering signal in these scenarios has been developed, tested, and implemented successfully. The technique involves removing material from the surface of the CR-39 to a depth beyond the endpoint ofmore » the ablator ion tracks. The technique preserves signal magnitude (yield) as well as structure in radiograph images. The technique is effective when signal particle range is at least 10 μm deeper than the necessary bulk material removal.« less
Ge, Jing; Yang, Chi; Zheng, Jiawei; Qian, Wentao
2016-03-01
The aim of this study was to evaluate the effect and safety of lingual split technique using piezosurgery for the extraction of lingual positioned impacted mandibular 3rd molars with the goal of proposing a more minimally invasive choice for this common surgery.Eighty-nine consecutive patients with 110 lingual positioned impacted mandibular 3rd molars requiring extraction were performed the lingual split technique using piezosurgery. One sagittal osteotomy line and 2 transverse osteotomy line were designed for lingual and occlusal bone removal. The success rate, operative time, postoperative outcome, and major complications (including nerve injury, mandible fracture, severe hematoma or edema, and severe pyogenic infection) were documented and analyzed.All impacted mandibular 3rd molars were successfully removed (110/110). The average time of operation was 14.6 minutes (ranged from 7 to 28 minutes). One hundred and seven extraction sites (97.3%) were primary healing. Pain, mouth opening, swelling, and PoSSe scores on postoperative 7-day were 0.34 ± 0.63, 3.88 ± 0.66(cm), 2.4 ± 0.2(cm), and 23.7 ± 5.9, respectively. There were 6 cases (5.5%) had lingual nerve disturbance and 3 cases (2.7%) developed inferior alveolar nerve impairment, and achieved full recovery within 2 months by neurotrophic drug treatment.Our study suggested piezosurgery for lingual split technique provided an effective way for the extraction of lingual positioned and deeply impacted mandibular 3rd molar.
Ge, Jing; Yang, Chi; Zheng, Jiawei; Qian, Wentao
2016-01-01
Abstract The aim of this study was to evaluate the effect and safety of lingual split technique using piezosurgery for the extraction of lingual positioned impacted mandibular 3rd molars with the goal of proposing a more minimally invasive choice for this common surgery. Eighty-nine consecutive patients with 110 lingual positioned impacted mandibular 3rd molars requiring extraction were performed the lingual split technique using piezosurgery. One sagittal osteotomy line and 2 transverse osteotomy line were designed for lingual and occlusal bone removal. The success rate, operative time, postoperative outcome, and major complications (including nerve injury, mandible fracture, severe hematoma or edema, and severe pyogenic infection) were documented and analyzed. All impacted mandibular 3rd molars were successfully removed (110/110). The average time of operation was 14.6 minutes (ranged from 7 to 28 minutes). One hundred and seven extraction sites (97.3%) were primary healing. Pain, mouth opening, swelling, and PoSSe scores on postoperative 7-day were 0.34 ± 0.63, 3.88 ± 0.66(cm), 2.4 ± 0.2(cm), and 23.7 ± 5.9, respectively. There were 6 cases (5.5%) had lingual nerve disturbance and 3 cases (2.7%) developed inferior alveolar nerve impairment, and achieved full recovery within 2 months by neurotrophic drug treatment. Our study suggested piezosurgery for lingual split technique provided an effective way for the extraction of lingual positioned and deeply impacted mandibular 3rd molar. PMID:27015214
Identification of Terrestrial Reflectance From Remote Sensing
NASA Technical Reports Server (NTRS)
Alter-Gartenberg, Rachel; Nolf, Scott R.; Stacy, Kathryn (Technical Monitor)
2000-01-01
Correcting for atmospheric effects is an essential part of surface-reflectance recovery from radiance measurements. Model-based atmospheric correction techniques enable an accurate identification and classification of terrestrial reflectances from multi-spectral imagery. Successful and efficient removal of atmospheric effects from remote-sensing data is a key factor in the success of Earth observation missions. This report assesses the performance, robustness and sensitivity of two atmospheric-correction and reflectance-recovery techniques as part of an end-to-end simulation of hyper-spectral acquisition, identification and classification.
Laparoscopic salpingectomy and removal of Essure hysteroscopic sterilisation device: a case series.
Johal, T; Kuruba, N; Sule, M; Mukhopadhyay, S; Raje, G
2018-06-01
Tubal sterilisation using Essure is a minimally invasive technique for permanent contraception, with high rates of patient satisfaction. However, some women subsequently choose removal of the inserts, due to side effects such as pelvic pain, abnormal bleeding, dyspareunia or allergic dermatitis. This case series presents the management of eight women who underwent laparoscopic removal of Essure inserts in conjunction with salpingectomy. We describe our surgical technique, its underlying principles and immediate surgical outcomes. Eight patients were identified as having undergone removal of Essure inserts, via an electronic search of the surgical procedures database. A retrospective review of case records was undertaken. The primary outcome was safety and feasibility of the laparoscopic salpingectomy approach. Secondary outcome measures included implant fracture rate, operative time, blood loss and length of patient stay. All eight women were able to undergo laparoscopic salpingectomy and removal of the Essure inserts without the need for laparotomy or hysterectomy. There were no incidences of fracture or incomplete removal of the insert. Immediate postoperative recovery was uncomplicated in all eight women; the mean length of stay was 17 h. One patient had a small bowel serosal tear attributed to laparoscopic entry. This case series suggests that laparoscopic salpingectomy for removal of Essure inserts is safe and feasible. We acknowledge that the numbers were small. However, consistent use of a laparoscopic approach in these eight patients indicates that this procedure is a feasible and suitable alternative to hysterectomy.
Krunić, Jelena; Stojanović, Nikola; Đukić, Ljiljana; Roganović, Jelena; Popović, Branka; Simić, Ivana; Stojić, Dragica
2018-06-01
To evaluate local effect of gaseous ozone on bacteria in deep carious lesions after incomplete caries removal, using chlorhexidine as control, and to investigate its effect on pulp vascular endothelial growth factor (VEGF), neuronal nitric oxide synthase (nNOS), and superoxide dismutase (SOD). Antibacterial effect was evaluated in 48 teeth with diagnosed deep carious lesion. After incomplete caries removal, teeth were randomly allocated into two groups regarding the cavity disinfectant used: ozone (open system) or 2% chlorhexidine. Dentin samples were analyzed for the presence of total bacteria and Lactobacillus spp. by real-time quantitative polymerase chain reaction. For evaluation of ozone effect on dental pulp, 38 intact permanent teeth indicated for pulp removal/tooth extraction were included. After cavity preparation, teeth were randomly allocated into two groups: ozone group and control group. VEGF/nNOS level and SOD activity in dental pulp were determined by enzyme-linked immunosorbent assay and spectrophotometric method, respectively. Ozone application decreased number of total bacteria (p = 0.001) and Lactobacillus spp. (p < 0.001), similarly to chlorhexidine. The VEGF (p < 0.001) and nNOS (p = 0.012) levels in dental pulp after ozone application were higher, while SOD activity was lower (p = 0.001) comparing to those in control pulp. Antibacterial effect of ozone on residual bacteria after incomplete caries removal was similar to that of 2% chlorhexidine. Effect of ozone on pulp VEGF, nNOS, and SOD indicated its biocompatibility. Ozone appears as effective and biocompatible cavity disinfectant in treatment of deep carious lesions by incomplete caries removal technique.
Ahmad Khan, Hayat; Kamal, Younis; Lone, Ansar Ul Haq
2014-04-01
Fishing is a leisure activity for some people around the world. Accidently the fish hook can get hooked in the hand. If the hook is barbed, removal becomes difficult. We report a case of such a injury in the hand and discuss the technique for its removal with a brief review of the literature. A thirty-two year old male accidently suffered a fishhook injury to his hand. He came to the orthopaedic ward two hours after the incident with pain; the fish hook was hanging from the hand. Unsuccessful attempts to remove it were made by his relatives. A push-through and cut-off technique was used for removal of barbed hook. Barbed hooks are to be removed atraumatically with controlled incision over properly anaesthetised skin. Proper wound management and prophylactic antibiotics suitable for treatment of Aeromonas species should be initiated to prevent complications.
Water reuse systems: A review of the principal components
Lucchetti, G.; Gray, G.A.
1988-01-01
Principal components of water reuse systems include ammonia removal, disease control, temperature control, aeration, and particulate filtration. Effective ammonia removal techniques include air stripping, ion exchange, and biofiltration. Selection of a particular technique largely depends on site-specific requirements (e.g., space, existing water quality, and fish densities). Disease control, although often overlooked, is a major problem in reuse systems. Pathogens can be controlled most effectively with ultraviolet radiation, ozone, or chlorine. Simple and inexpensive methods are available to increase oxygen concentration and eliminate gas supersaturation, these include commercial aerators, air injectors, and packed columns. Temperature control is a major advantage of reuse systems, but the equipment required can be expensive, particularly if water temperature must be rigidly controlled and ambient air temperature fluctuates. Filtration can be readily accomplished with a hydrocyclone or sand filter that increases overall system efficiency. Based on criteria of adaptability, efficiency, and reasonable cost, we recommend components for a small water reuse system.
Simplification of reversible Markov chains by removal of states with low equilibrium occupancy.
Ullah, Ghanim; Bruno, William J; Pearson, John E
2012-10-21
We present a practical method for simplifying Markov chains on a potentially large state space when detailed balance holds. A simple and transparent technique is introduced to remove states with low equilibrium occupancy. The resulting system has fewer parameters. The resulting effective rates between the remaining nodes give dynamics identical to the original system's except on very fast timescales. This procedure amounts to using separation of timescales to neglect small capacitance nodes in a network of resistors and capacitors. We illustrate the technique by simplifying various reaction networks, including transforming an acyclic four-node network to a three-node cyclic network. For a reaction step in which a ligand binds, the law of mass action implies a forward rate proportional to ligand concentration. The effective rates in the simplified network are found to be rational functions of ligand concentration. Copyright © 2012 Elsevier Ltd. All rights reserved.
Sahar-Helft, Sharonit; Sarp, Ayşe Sena Kabaş; Stabholtz, Adam; Gutkin, Vitaly; Redenski, Idan; Steinberg, Doron
2015-03-01
The purpose of this study was to compare the efficacy of three irrigation techniques for smear-layer removal with 17% EDTA. Cleaning and shaping the root canal system during endodontic treatment produces a smear layer and hard tissue debris. Three irrigation techniques were tested for solution infiltration of this layer: positive-pressure irrigation, passive ultrasonic irrigation, and laser-activated irrigation. Sixty extracted teeth were divided into six equal groups; 17% EDTA was used for 60 sec irrigation of five of the groups. The groups were as follows: Group 1, treated only with ProTaper™ F3 Ni-Ti files; Group 2, positive-pressure irrigation, with a syringe; Group 3, passive ultrasonic irrigation, inserted 1 mm short of the working length; Group 4, passive ultrasonic irrigation, inserted in the upper coronal third of the root; Group 5, Er:YAG laser-activated irrigation, inserted 1 mm short of the working length; and Group 6, Er:YAG laser-activated irrigation, inserted in the upper coronal third of the root. Scanning electron microscopy showed that the smear layer is removed most efficiently using laser-activated irrigation at low energy with 17% EDTA, inserted either at the working length or only in the coronal upper third of the root. Amounts of Ca, P, and O were not significantly different on all treated dentin surfaces. Smear-layer removal was most effective when the root canals were irrigated using Er:YAG laser at low energy with 17% EDTA solution. Interestingly, removal of the smear layer along the entire canal was similar when the laser was inserted in the upper coronal third and at 1 mm short of the working length of the root canal. This effect was not observed with the ultrasonic and positive-pressure techniques.
Cleansing technique using high-velocity steam-air micromist jet spray.
Fukuda, Koichi; Ishihara, Masayuki; Murakami, Kaoru; Nakamura, Shingo; Sato, Yoko; Kuwabara, Masahiro; Fujita, Masanori; Kiyosawa, Tomoharu; Yokoe, Hidetaka
2017-10-01
Application of a high-velocity steam-air micromist jet spray (HVS-AMJS; micromist average diameter: 2.4 μm) for cleansing the skin is proposed. Low-pressure steam is mixed with compressed air (pH 6.5) in a nozzle, and then sprayed at a pressure of ≦0.25 MPa and a velocity of ≧0.34 m/s on the skin or surface of material located approximately 5-10 cm from the nozzle. The temperature on the sprayed surface and water flow rate could be controlled between 42 °C and 46 °C and at approximately 50 mL/min, respectively. Compared with ultrasonic cleansing with tap water and rubbing with only tap water, the HVS-AMJS successfully removed fluorescent lotion covering pieces of wood and significantly reduced both the number of coliforms and the total viable counts on pieces of wood and gauze. Furthermore, the HVS-AMJS effectively removed oily ink from the skin of hairless rats, and temporarily elevated the skin temperature and blood flow, indicating massage effects. The striking characteristics of this cleansing technique using HVS-AMJS are not only its ability to remove microbes and residue without using any chemicals or detergents but also its massage effects.
Pratt, C; Shilton, A
2010-01-01
Active filtration, where effluent is passed through a reactive substrate such as steel slag, offers a simple and cost-effective option for removing phosphorus (P) from effluent. This work summarises a series of studies that focused on the world's only full-scale active slag filter operated through to exhaustion. The filter achieved 75% P-removal during its first 5 years, reaching a retention capacity of 1.23 g P/kg slag but then its performance sharply declined. Scanning electron microscopy, X-ray diffraction, X-ray fluorescence, and chemical extractions revealed that P sequestration was primarily achieved via adsorption onto iron (Fe) oxyhydroxides on the slag's surface. It was concluded that batch equilibrium tests, whose use has been repeatedly proposed in the literature, cannot be used as an accurate predictor of filter adsorption capacity because Fe oxyhydroxides form via chemical weathering in the field, and laboratory tests don't account for this. Research into how chemical conditions affect slag's P retention capacity demonstrated that near-neutral pH and high redox are optimal for Fe oxyhydroxide stability and overall filter performance. However, as Fe oxyhydroxide sites fill up, removal capacity becomes exhausted. Attempts to regenerate P removal efficiency using physical techniques proved ineffective contrary to dogma in the literature. Based on the newly-developed understanding of the mechanisms of P removal, chemical regeneration techniques were investigated and were shown to strip large quantities of P from filter adsorption sites leading to a regenerated P removal efficiency. This raises the prospect of developing a breakthrough technology that can repeatedly remove and recover P from effluent.
Cyclic process for producing methane in a tubular reactor with effective heat removal
Frost, Albert C.; Yang, Chang-Lee
1986-01-01
Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.
Effects of Humidity Swings on Adsorption Columns for Air Revitalization: Modeling and Experiments
NASA Technical Reports Server (NTRS)
LeVan, M. Douglas; Finn, John E.
1997-01-01
Air purification systems are necessary to provide clean air in the closed environments aboard spacecraft. Trace contaminants are removed using adsorption. One major factor concerning the removal of trace contaminants is relative humidity. Water can reduce adsorption capacity and, due to constant fluctuations, its presence is difficult to incorporate into adsorption column designs. The purpose of the research was to allow for better design techniques in trace contaminant adsorption systems, especially for feeds with water present. Experiments and mathematical modeling research on effects of humidity swings on adsorption columns for air revitalization were carried out.
NASA Astrophysics Data System (ADS)
Fosso-Kankeu, Elvis
2018-06-01
In the present study af-PFCl, GL-g-P(AN) hydrogel and GL-g-P(AN)/TEOS hydrogel composite were synthesized. The hydrogels were characterized using the fourier transformed infra-red (FTIR) and the scanning electron microscope (SEM) techniques. The coagulant af-PFCl and the hydrogels were applied consecutively in flocculation and adsorption processes respectively for the treatment of acid mine drainage (AMD). It was observed that the grafting process increased the amount of binding groups on the hydrogels. The hybridization of the techniques assisted in the removal of anions; while the cations were mostly removed by the adsorption process. The adsorbents behaviour was fittingly expressed by the pseudo-second order model. The adsorption capacities of GL-g-P(AN)/TEOS hydrogel composite for the removal of Al, As and Zn were 3.89, 0.66 and 0.394 respectively; while the adsorption capacities of GL-g-P(AN) for the removal of Al and Mg were 3.47 and 9.66 mg/g respectively. The techniques applied in this study have shown good potential for the removal of specific pollutants from the AMD; it is however, important that the appropriate hybridization of techniques allows to remove all the pollutants and restore acceptable water quality.
Ma, Si; Liu, Changli; Yang, Kun; Lin, Daohui
2012-11-15
Discharged carbon nanotubes (CNTs) can adsorb the widely-distributed humic acid (HA) in aquatic environments and thus be stabilized. HA-stabilized CNTs can find their way into and challenge the potable water treatment system. This study investigated the efficiency of coagulation and sedimentation techniques in the removal of the HA-stabilized multi-walled carbon nanotubes (MWCNTs) using polyaluminum chloride (PACl) as a coagulant, with a focus on the effects of hydraulic conditions and water chemistry. Stirring speeds in the mixing and reacting stages were gradually changed to examine the effect of the hydraulic conditions on the removal rate. The stirring speed in the reacting stage affected floc formation and thereby had a greater impact on the removal rate than the stirring speed in the mixing stage. Water chemistry factors such as pH and ionic strength had a significant effect on the stability of MWCNT suspension and the removal efficiency. Low pH (4-7) was favorable for saving the coagulant and maintaining high removal efficiency. High ionic strength facilitated the destabilization of the HA-stabilized MWCNTs and thereby lowered the required PACl dosage for the coagulation. However, excessively high ionic strength (higher than the critical coagulation concentration) decreased the maximum removal rate, probably by inhibiting ionic activity of PACl hydrolyzate in water. These results are expected to shed light on the potential improvement of coagulation removal of aqueous stabilized MWCNTs in water treatment systems. Copyright © 2012 Elsevier B.V. All rights reserved.
Dong, J; Lu, J; Zu, Q; Yang, S; Sun, S; Cai, W; Zhang, L; Zhang, X
2011-12-01
We evaluated routine short-time insertion of ureteral stent in living donor renal transplant at a single center. It was easy to remove the stent without cystoscopy and anesthesia. Between October 2007 and July 2010, a single surgeon performed 76 living donor renal transplantations at one institute. All recipients underwent extravesical ureteroneocystostomy with a 2-0 silk suture passed through the venting side hole of the double-J stent into the bladder; a quadruple knot prevented the suture's slippage or distraction from the stent. After removal of the indwelling catheter at 5 days posttransplantation, the 2-0 silk passed with the urinary stream within 72 hours. The double-J stent was removed at 7 to 10 (mean 8.4) days after kidney transplantation by pulling the 2-0 silk out of the urethral orifice without anesthesia or cystoscopy. There was only one case of stenosis, which was resolved by surgery. No patient developed urinary leakage. There were three episodes of urinary tract infection in 70 patients during first 6 months' follow-up. Routine short-term stenting is a safe and effective technique in living donor renal transplantation. Removal of the stent is feasible without cystoscopy or anesthesia. Copyright © 2011 Elsevier Inc. All rights reserved.
Kumar, Anuj; Priyadarshinee, Rashmi; Roy, Abhishek; Dasgupta, Dalia; Mandal, Tamal
2016-12-01
Rice mills release huge volumes of wastewater and other by-products when processing paddy rice. The wastewater often contains toxic inorganic and organic contaminants which cause environmental damage when released. Accordingly, cost-effective techniques for removing contaminants are needed. This article reviews current processes for curbing pollution and also reusing and recycling waste products. Novel techniques exist for converting waste products into energy and value-added products. Copyright © 2016 Elsevier Ltd. All rights reserved.
Boboridis, Konstadinos G; Uddin, Jimmy; Mikropoulos, Dimitrios G; Bunce, Catey; Mangouritsas, George; Voudouragkaki, Irini C; Konstas, Anastasios G P
2015-07-01
Orbital decompression is the indicated procedure for addressing exophthalmos and compressive optic neuropathy in thyroid eye disease. There are an abundance of techniques for removal of orbital bone, fat, or a combination published in the scientific literature. The relative efficacy and complications of these interventions in relation to the specific indications remain as yet undocumented. We performed a systematic review of the current published evidence for the effectiveness of orbital decompression, possible complications, and impact on quality of life. We searched the current databases for medical literature and controlled trials, oculoplastic textbooks, and conference proceedings to identify relevant data up to February 2015. We included randomized controlled trials (RCTs) comparing two or more interventions for orbital decompression. We identified only two eligible RCTs for inclusion in the review. As a result of the significant variability between studies on decompression, i.e., methodology and outcome measures, we did not perform a meta-analysis. One study suggests that the transantral approach and endonasal technique had similar effects in reducing exophthalmos but the latter is safer. The second study provides evidence that intravenous steroids may be superior to primary surgical decompression in the management of compressive optic neuropathy requiring less secondary surgical procedures. Most of the published literature on orbital decompression consists of retrospective, uncontrolled trials. There is evidence from those studies that removal of the medial and lateral wall (balanced) and the deep lateral wall decompression, with or without fat removal, may be the most effective surgical methods with only few complications. There is a clear unmet need for controlled trials evaluating the different techniques for orbital decompression. Ideally, future studies should address the effectiveness, possible complications, quality of life, and cost of each intervention.
Effectiveness of rotary or manual techniques for removing a 6-year-old filling material.
Duarte, Marco Antônio Hungaro; Só, Marcus Vinícius Reis; Cimadon, Vanessa Buffon; Zucatto, Cristiane; Vier-Pelisser, Fabiana Vieira; Kuga, Milton Carlos
2010-01-01
The aim of this study was to evaluate the effectiveness of manual and rotary instrumentation techniques for removing root fillings after different storage times. Twenty-four canals from palatal roots of human maxillary molars were instrumented and filled with gutta-percha and zinc-oxide eugenol-based sealer (Endofill) , and were stored in saline for 6 years. Non-aged control specimens were treated in the same manner and stored for 1 week. All canals were retreated using hand files or ProTaper Universal NiTi rotary system. Radiographs were taken to determine the amount of remaining material in the canals. The roots were vertically split, the halves were examined with a clinical microscope and the obtained images were digitized. The images were evaluated with AutoCAD software and the percentage of residual material was calculated. Data were analyzed with two-way ANOVA and Tukey's test at 5% significance level. There was no statistically significant differences (p>0.05) between the manual and rotary techniques for filling material removal regardless the ageing effect on endodontic sealers. When only the age of the filling material was analyzed microscopically, non-aged fillings that remained on the middle third of the canals presented a higher percentage of material remaining (p<0.05) compared to the aged sealers and to the other thirds of the roots. The apical third showed a higher percentage of residual filling material in both radiographic and microscopic analysis when compared to the other root thirds. In conclusion, all canals presented residual filling material after endodontic retreatment procedures. Microscopic analysis was more effective than radiographs for detection of residual filling material.
NASA Astrophysics Data System (ADS)
Chen, Yuan-Yuan; Yu, Sheng-Hui; Jiang, Hao-Fan; Yao, Qi-Zhi; Fu, Sheng-Quan; Zhou, Gen-Tao
2018-06-01
Hierarchical vaterite spherulites, synthesized by a simple injection-precipitation method at room temperature, were applied for the simultaneous removal of heavy metal Cd(II) and dye Congo red (CR) from aqueous solution. Batch experiments reveal that the maximum removal capacities of as-prepared vaterite spherulites to Cd(II) and CR are 984.5 and 89.0 mg/g, respectively, showing excellent removal performance for Cd(II) and CR. Furthermore, in the binary Cd(II)-CR system, the removal capacity of vaterite to Cd(II) is significantly enhanced at lower CR concentration (<100 mg/L), but inhibited at higher CR concentration (>100 mg/L). In contrast, the concurrent Cd(II) shows negligible effect on the CR removal. The simultaneous removal mechanism was investigated by FESEM, EDX, XRD, FT-IR and XPS techniques. The simultaneous removal of Cd(II) and CR in the binary system is shown to be a multistep process, involving the preferential adsorption of dye CR, stabilization of CR to vaterite, coordination of the adsorbed CR molecules with Cd(II), and transformation of vaterite into otavite. Given the facile and green synthesis procedure, and effective removal of Cd(II) and CR in the binary system, the obtained vaterite spherulites have considerable practical interest in integrative treatment of wastewater contaminated by heavy metals and dyes.
Ejhed, H; Fång, J; Hansen, K; Graae, L; Rahmberg, M; Magnér, J; Dorgeloh, E; Plaza, G
2018-03-15
Micropollutants such as pharmaceuticals, hormones and phenolic utility chemicals in sewage water are considered to be an emerging problem because of increased use and observed adverse effects in the environment. The study provides knowledge on the removal efficiency of micropollutants with a range of physical and chemical properties in three commercially available onsite wastewater treatment facilities (OWTFs), tested on influent wastewater collected from 2500 person equivalents in Bildchen, Germany. A longer hydraulic retention time would in theory be expected to have a positive effect, and this study presents results for three different OWTFs in full-scale comparable tests under natural conditions. A range of 24 different pharmaceuticals, five phenols and three hormones were analyzed. Flow-proportional consecutive sampling was performed in order to determine the removal efficiency. Twenty-eight substances were detected in the effluent wastewater out of 32 substances included. Average effluent concentrations of Simvastatin, Estrone, Estradiol and Ethinylestradiol were above the indicative critical-effect concentration of pharmacological effect on fish in all facilities. Average effluent concentrations of both Diclofenac and Estradiol were higher than the Environmental Quality Standards applied in Sweden (190-240 times and 9-35 times respectively). The removal efficiency of micropollutants was high for substances with high logK ow , which enhance the adsorption and removal with sludge. Low removal was observed for substances with low logK ow and acidic characteristics, and for substances with stabilizing elements of the chemical structure. Facilities that use activated sludge processes removed hormones more efficiently than facilities using trickling filter treatment technique. Moreover, longer hydraulic retention time increased the removal of pharmaceuticals, hormones, turbidity and total nitrogen. Removal of Caffeine, Ibuprofen, Estrone, Naproxen and Estradiol, was strongly correlated to the sludge and particles removal. Thus, the efficiency of the tested OWTFs could be improved by adjusting the technical methods and increasing the hydraulic retention time. Copyright © 2017 Elsevier B.V. All rights reserved.
Testing ecological tradeoffs of a new tool for removing fine sediment in a spring-fed stream
Sepulveda, Adam; Sechrist, Juddson D.; Marczak, Laurie B
2014-01-01
Excessive fine sediment is a focus of stream restoration work because it can impair the structure and function of streams, but few methods exist for removing sediment in spring-fed streams. We tested a novel method of sediment removal with the potential to have minimal adverse effects on the biological community during the restoration process. The Sand Wand system, a dredgeless vacuum developed by Streamside Technologies, was used to experimentally remove fine sediment from Kackley Springs, a spring creek in southeastern Idaho. We assessed the effects of the Sand Wand on stream physical habitat and macroinvertebrate composition for up to 60 days after the treatment. We documented changes in multiple habitat variables, including stream depth, median particle size, and the frequency of embedded substrate in stream reaches that were treated with the Sand Wand. We also found that macroinvertebrate composition was altered even though common macroinvertebrate metrics changed little after the treatment. Our results suggest that the Sand Wand was effective at removing fine sediments in Kackley Springs and did minimal harm to macroinvertebrate function, but the Sand Wand was not ultimately effective in improving substrate composition to desired conditions. Additional restoration techniques are still needed to decrease the amount of fine sediment.
NASA Astrophysics Data System (ADS)
Azhar, A. T. S.; Nabila, A. T. A.; Nurshuhaila, M. S.; Zaidi, E.; Azim, M. A. M.; Farhana, S. M. S.
2016-11-01
Landfills are major sources of contamination due to the presence of harmful bacteria and heavy metals. Electrokinetic-Bioremediation (Ek-Bio) is one of the techniques that can be conducted to remediate contaminated soil. Therefore, the most prominent bacteria from landfill soil will be isolated to determine their optimal conditions for culture and growth. The degradation rate and the effectiveness of selected local bacteria were used to reduce soil contamination. Hence, this enhances microbiological activities to degrade contaminants in soil and reduce the content of heavy metals. The aim of this study is to investigate the ability of isolated bacteria (Lysinibacillus fusiformis) to remove mercury in landfill soil. 5 kg of landfill soil was mixed with deionized water to make it into slurry condition for the purpose of electrokinetic and bioremediation. This remediation technique was conducted for 7 days by using 50 V/m of electrical gradient and Lysinibacillus fusiformis bacteria was applied at the anode reservoir. The slurry landfill soil was located at the middle of the reservoir while distilled water was placed at the cathode of reservoir. After undergoing treatment for 7 days, the mercury analyzer showed that there was a significant reduction of approximately up to 78 % of mercury concentration for the landfill soil. From the results, it is proven that electrokinetic bioremediation technique is able to remove mercury within in a short period of time. Thus, a combination of Lysinibacillus fusiformis and electrokinetic technique has the potential to remove mercury from contaminated soil in Malaysia.
Yang, Hao; Cheng, Haobo; Feng, Yunpeng; Jing, Xiaoli
2018-05-01
Subaperture polishing techniques usually produce rolled edges due to edge effect. The rolled edges, especially those in millimeter scale on small components, are difficult to eliminate using conventional polishing methods. Magnetorheological jet polishing (MJP) offers the possibility of the removal of these structures, owing to its small tool influence function (TIF) size. Hence, we investigate the removal characters of inclined MJP jetting models by means of computational fluid dynamics (CFD) simulations and polishing experiments. A discrete phase model (DPM) is introduced in the simulation to get the influence of abrasive particle concentration on the removal mechanism. Therefore, a more accurate model for MJP removal mechanisms is built. With several critical problems solved, a small bevel-cut-like TIF (B-TIF), which has fine acentric and unimodal characteristics, is obtained through inclined jetting. The B-TIF proves to have little edge effect and is applied in surface polishing of thin rolled edges. Finally, the RMS of the experimental section profile converges from 10.5 nm to 1.4 nm, and the rolled edges are successfully suppressed. Consequently, it is validated that the B-TIF has remarkable ability in the removal of millimeter-scale rolled edges.
Vivek Narayanan, N; Ganesan, Mahesh
2009-01-15
The present work deals with removal of hexavalent chromium from synthetic effluents in a batch stirred electrocoagulation cell with iron-aluminium electrode pair coupled with adsorption using granular activated carbon (GAC). Several working parameters such as pH, current density, adsorbent concentration and operating time were studied in an attempt to achieve higher removal capacity. Results obtained with synthetic wastewater revealed that most effective removal capacities of chromium (VI) could be achieved when the initial pH was near 8. The removal of chromium (VI) during electrocoagulation, is due to the combined effect of chemical precipitation, coprecipitation, sweep coagulation and adsorption. In addition, increasing current density in a range of 6.7-26.7mA/cm2 and operating time from 20 to 100min enhanced the treatment rate to reduce metal ion concentration below admissible legal levels. The addition of GAC as adsorbent resulted in remarkable increase in the removal rate of chromium at lower current densities and operating time, than the conventional electrocoagulation process. The method was found to be highly efficient and relatively fast compared to existing conventional techniques.
The Effect of the Multivariate Box-Cox Transformation on the Power of MANOVA.
ERIC Educational Resources Information Center
Kirisci, Levent; Hsu, Tse-Chi
Most of the multivariate statistical techniques rely on the assumption of multivariate normality. The effects of non-normality on multivariate tests are assumed to be negligible when variance-covariance matrices and sample sizes are equal. Therefore, in practice, investigators do not usually attempt to remove non-normality. In this simulation…
Air-guided manual deep lamellar keratoplasty.
Caporossi, A; Simi, C; Licignano, R; Traversi, C; Balestrazzi, A
2004-01-01
To evaluate the efficacy of a new modified technique of deep lamellar keratoplasty (DLK). Nine eyes of eight patients with keratoconus of moderate degree were included. All patients underwent DLK with manual dissection from a limbal side port after an air bubble injection in the anterior chamber. The patients underwent a complete ophthalmologic examination 6 months after the suture removal, evaluating best-corrected visual acuity, corneal thickness, endothelial cell count, and topographic astigmatism. One case (11.1%) was converted to penetrating keratoplasty because of microperforation. In the eight successful cases, 7 eyes (77.8%) achieved 20/30 or better visual acuity 6 months after suture removal. Mean postoperative pachymetry was 604.76 microm (SD 46.76). Specular microscopy 6 months after suture removal revealed average endothelial cell count of 2273/mm2 (SD 229). This modified DLK technique is a safe and effective procedure and could facilitate, after a short learning curve, this kind of surgery with a low risk of conversion to penetrating keratoplasty.
Laser treatments of deep-seated brain lesions
NASA Astrophysics Data System (ADS)
Ward, Helen A.
1997-06-01
The five year survival rate of deep-seated malignant brain tumors after surgery/radiotherapy is virtually 100 percent mortality. Special problems include: (1) Lesions often present late. (2) Position: lesion overlies vital structures, so complete surgical/radiotherapy lesion destruction can damage vital brain-stem functions. (3) Difficulty in differentiating normal brain form malignant lesions. This study aimed to use the unique properties of the laser: (a) to minimize damage during surgical removal of deep-seated brain lesions by operating via fine optic fibers; and (b) to employ the propensity of certain lasers for absorption of dyes and absorption and induction of fluorescence in some brain substances, to differentiate borders of malignant and normal brain, for more complete tumor removal. In the method a fine laser endoscopic technique was devised for removal of brain lesions. The results of this technique, were found to minimize and accurately predict the extent of thermal damage and shock waves to within 1-2mm of the surgical laser beam. Thereby it eliminated the 'popcorn' effect.
NASA Astrophysics Data System (ADS)
Arun, Sija; Kothari, Kaushal; Mazumdar, Debayan; Mukhopadhyay, Moitraiyee; Chakraborty, Paromita
2017-08-01
Due to the broad spectrum, antimicrobial activity, Amoxicillin is one of the extensively used antibiotics. Amoxicillin ends up in the wastewater stream by direct or indirect disposal pathways which ultimately affect the aquatic ecosystem. Conventional wastewater treatment plant cannot remove it completely. Hence our objective was to produce sludge derived biochar and use it as an adsorbent for removal of amoxicillin. Effective biochar was obtained at 300°C produced from the sludge of the domestic wastewater treatment plant. 100 ppm amoxicillin solution spiked in biochar was kept for 180 mins in an orbital shaker and every 30 minutes the filtrate was checked in UV spectrophotometer. A steady decreasing gradient was obtained for absorbance of amoxicillin after 30 minutes. Further scanning electron microscopy showed significant morphological change in biochar obtained before and after spiking amoxicillin. Our preliminary assessment suggests that biochar can be exploited as an effective treatment technique to remove amoxicillin from wastewater. Moreover, we suggest that utilization of domestic sludge for commercial application in treatment plants can reduce the load of domestic waste in the open dumpsites.
A Novel Stimulus Artifact Removal Technique for High-Rate Electrical Stimulation
Heffer, Leon F; Fallon, James B
2008-01-01
Electrical stimulus artifact corrupting electrophysiological recordings often make the subsequent analysis of the underlying neural response difficult. This is particularly evident when investigating short-latency neural activity in response to high-rate electrical stimulation. We developed and evaluated an off-line technique for the removal of stimulus artifact from electrophysiological recordings. Pulsatile electrical stimulation was presented at rates of up to 5000 pulses/s during extracellular recordings of guinea pig auditory nerve fibers. Stimulus artifact was removed by replacing the sample points at each stimulus artifact event with values interpolated along a straight line, computed from neighbouring sample points. This technique required only that artifact events be identifiable and that the artifact duration remained less than both the inter-stimulus interval and the time course of the action potential. We have demonstrated that this computationally efficient sample-and-interpolate technique removes the stimulus artifact with minimal distortion of the action potential waveform. We suggest that this technique may have potential applications in a range of electrophysiological recording systems. PMID:18339428
Adaptive box filters for removal of random noise from digital images
Eliason, E.M.; McEwen, A.S.
1990-01-01
We have developed adaptive box-filtering algorithms to (1) remove random bit errors (pixel values with no relation to the image scene) and (2) smooth noisy data (pixels related to the image scene but with an additive or multiplicative component of noise). For both procedures, we use the standard deviation (??) of those pixels within a local box surrounding each pixel, hence they are adaptive filters. This technique effectively reduces speckle in radar images without eliminating fine details. -from Authors
2012-10-01
selective of all gene-targeted, oligonucleotide-based drug approaches (better than ribozymes, antisense oligonucleotides ( ASO ), or microRNAs).(4) We will...respect to a scrambled siRNA control. For the migration assay, a circular region in the middle of the well was removed using a gel removal solution...oligonucleotides, ASOs ) into rabbit corneal cells and found that technique was very effective in delivering ASOs into the stroma and even into the endothelial cell
1987-05-01
Bruxism : a report and a case report. J. Dent. Med., 9:189-199, 1954. 138. Super, S: A modified occlusal splint for segmental osteotomy fixation. J. Oral...minimize linear dimensional change prior to the clinical use of a removable acrylic resin orthosis. . .. . . . . TABLE OF CONTENTS Title...distortion and clinical use of an orthosis having a precise and accurate fit. V % N II. LITERATURE REVIEW A. Terminology The therapeutic use of interocclusal
Chen, Jiangyao; Huang, Yong; Li, Guiying; An, Taicheng; Hu, Yunkun; Li, Yunlu
2016-01-25
Volatile organic compounds (VOCs) emitted during the electronic waste dismantling process (EWDP) were treated at a pilot scale, using integrated electrostatic precipitation (EP)-advanced oxidation technologies (AOTs, subsequent photocatalysis (PC) and ozonation). Although no obvious alteration was seen in VOC concentration and composition, EP technology removed 47.2% of total suspended particles, greatly reducing the negative effect of particles on subsequent AOTs. After the AOT treatment, average removal efficiencies of 95.7%, 95.4%, 87.4%, and 97.5% were achieved for aromatic hydrocarbons, aliphatic hydrocarbons, halogenated hydrocarbons, as well as nitrogen- and oxygen-containing compounds, respectively, over 60-day treatment period. Furthermore, high elimination capacities were also seen using hybrid technique of PC with ozonation; this was due to the PC unit's high loading rates and excellent pre-treatment abilities, and the ozonation unit's high elimination capacity. In addition, the non-cancer and cancer risks, as well as the occupational exposure cancer risk, for workers exposed to emitted VOCs in workshop were reduced dramatically after the integrated technique treatment. Results demonstrated that the integrated technique led to highly efficient and stable VOC removal from EWDP emissions at a pilot scale. This study points to an efficient approach for atmospheric purification and improving human health in e-waste recycling regions. Copyright © 2015 Elsevier B.V. All rights reserved.
Easy and safe coated optical fiber direct connection without handling bare optical fiber
NASA Astrophysics Data System (ADS)
Saito, Kotaro; Kihara, Mitsuru; Shimizu, Tomoya; Kurashima, Toshio
2015-06-01
We propose a novel field installable splicing technique for the direct connection of 250 μm diameter coated optical fiber that does not require bare optical fiber to be handled. Our proposed technique can realize a low insertion loss over a wide field installation temperature range of -10-40 °C. The keys to coated optical fiber direct connection are a cleaving technique and a technique for removing coated optical fiber. As the cleaving technique, we employed a method where the fiber is stretched and then a blade is pushed perpendicularly against the stretched fiber. As a result we confirmed that fiber endfaces cleaved at -10-40 °C were all mirror endfaces. With the removal technique, the coating is removed inside the connecting component by incorporating a circular cone shaped coating removal part. A mechanical splice based on these techniques successfully achieved a low insertion loss of less than 0.11 dB and a return loss of more than 50 dB at -10, 20, and 40 °C. In addition, the temperature cycle characteristics were stable over a wide temperature range of -40-75 °C.
Assessing LiDAR elevation data for KDOT applications.
DOT National Transportation Integrated Search
2013-02-01
LiDAR-based elevation surveys are a cost-effective means for mapping topography over large areas. LiDAR : surveys use an airplane-mounted or ground-based laser radar unit to scan terrain. Post-processing techniques are : applied to remove vegetation ...
Fine structure in the m/z 121 mass chromatogram of Paraho shale oil
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gallegos, E.J.
1984-04-01
High-resolution gas chromatography/high-resolution mass spectrometry/computer (HRGC/HRMS/C) techniques are reported here in the provisional identification of several homologous series of alkylpuridines, phenols, terpenes, and terpanes analytically isolated from Paraho shale oil. HRGC/HRMS/C techniques were also used to follow the hydrodenitrification, HDN, procedure for the removal of the heterocompounds, as well as to monitor the effect of hydrogenation on alkenes.
Enhanced performance of crumb rubber filtration for ballast water treatment.
Tang, Zhijian; Butkus, Michael A; Xie, Yuefeng F
2009-03-01
Waste-tire-derived crumb rubber was utilized as filter media to develop an efficient filter for ballast water treatment. In this study, the effects of coagulation, pressure filtration and dual-media (gravity) filtration on the performance of the crumb rubber filtration were investigated. The removal efficiencies of turbidity, phytoplankton and zooplankton, and head loss development were monitored during the filtration process. The addition of a coagulant enhanced the removal efficiencies of all targeted matter, but resulted in substantial increase of head loss. Pressure filtration increased filtration rates to 220 m(3)h(-1)m(-2) for 8-h operation and improved the zooplankton removal. Dual-media (crumb rubber/sand) gravity filtration also improved the removal efficiencies of phytoplankton and zooplankton over mono-media gravity crumb rubber filtration. However, these filtration techniques alone did not meet the criteria for removing indigenous organisms from ballast water. A combination of filtration and disinfection is suggested for future studies.
Townsend, F I; Ralphs, S C; Coronado, G; Sweet, D C; Ward, J; Bloch, C P
2012-01-01
To compare the hydro-surgical technique to traditional techniques for removal of subcutaneous tissue in the preparation of full-thickness skin grafts. Ex vivo experimental study and a single clinical case report. Four canine cadavers and a single clinical case. Four sections of skin were harvested from the lateral flank of recently euthanatized dogs. Traditional preparation methods used included both a blade or scissors technique, each of which were compared to the hydro-surgical technique individually. Preparation methods were compared based on length of time for removal of the subcutaneous tissue from the graft, histologic grading, and measurable thickness as compared to an untreated sample. The hydro-surgical technique had the shortest skin graft preparation time as compared to traditional techniques (p = 0.002). There was no significant difference in the histological grading or measurable subcutaneous thickness between skin specimens. The hydro-surgical technique provides a rapid, effective debridement of subcutaneous tissue in the preparation of full-thickness skin grafts. There were not any significant changes in histological grade and subcutaneous tissue remaining among all treatment types. Additionally the hydro-surgical technique was successfully used to prepare a full-thickness meshed free skin graft in the reconstruction of a traumatic medial tarsal wound in a dog.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheth, Rahul; Someshwar, Vimal; Warawdekar, Gireesh
2007-02-15
Purpose. We report our experience of the retrieval of intravascular foreign body objects by the percutaneous use of the Gemini Dormia basket. Methods. Over a period of 2 years we attempted the percutaneous removal of intravascular foreign bodies in 26 patients. Twenty-six foreign bodies were removed: 8 intravascular stents, 4 embolization coils, 9 guidewires, 1 pacemaker lead, and 4 catheter fragments. The percutaneous retrieval was achieved with a combination of guide catheters and the Gemini Dormia basket. Results. Percutaneous retrieval was successful in 25 of 26 patients (96.2%). It was possible to remove all the intravascular foreign bodies with amore » combination of guide catheters and the Dormia basket. No complication occurred during the procedure, and no long-term complications were registered during the follow-up period, which ranged from 6 months to 32 months (mean 22.4 months overall). Conclusion. Percutaneous retrieval is an effective and safe technique that should be the first choice for removal of an intravascular foreign body.« less
Rice, K.G.; Waddle, J.H.; Miller, M.W.; Crockett, M.E.; Mazzotti, F.J.; Percival, H.F.
2011-01-01
Florida is home to several introduced animal species, especially in the southern portion of the state. Most introduced species are restricted to the urban and suburban areas along the coasts, but some species, like the Cuban Treefrog (Osteopilus septentrionalis), are locally abundant in natural protected areas. Although Cuban Treefrogs are known predators of native treefrog species as both adults and larvae, no study has demonstrated a negative effect of Cuban Treefrogs on native treefrog survival, abundance, or occupancy rate. We monitored survival, capture probability, abundance, and proportion of sites occupied by Cuban Treefrogs and two native species, Green Treefrogs (Hyla cinerea) and Squirrel Treefrogs (Hyla squirella), at four sites in Everglades National Park in southern Florida with the use of capture–mark–recapture techniques. After at least 5 mo of monitoring all species at each site we began removing every Cuban Treefrog captured. We continued to estimate survival, abundance, and occupancy rates of native treefrogs for 1 yr after the commencement of Cuban Treefrog removal. Mark–recapture models that included the effect of Cuban Treefrog removal on native treefrog survival did not have considerable Akaike's Information Criterion (AIC) weight, although capture rates of native species were generally very low prior to Cuban Treefrog removal. Estimated abundance of native treefrogs did increase after commencement of Cuban Treefrog removal, but also varied with the season of the year. The best models of native treefrog occupancy included a Cuban Treefrog removal effect at sites with high initial densities of Cuban Treefrogs. This study demonstrates that an introduced predator can have population-level effects on similar native species.
Evaluation of polyacrylonitrile electrospun nano-fibrous mats as leukocyte removal filter media.
Pourbaghi, Raha; Zarrebini, Mohammad; Semnani, Dariush; Pourazar, Abbasali; Akbari, Nahid; Shamsfar, Reihaneh
2018-07-01
Removal of leukocytes from blood products is the most effective means for elimination of undesirable side effects and prevention of possible reactions in recipients. Micro-fibrous mats are currently used for removal of leukocytes from blood. In this study, samples of electrospun nano-fibrous mats were produced. The performance of the produced electrospun nano-fibrous mats as means of leukocytes removal from fresh whole blood was both evaluated and compared with that of commercially available micro-fibrous mats. In order to produce the samples, polyacrylonitrile (PAN) nano-fibrous mats were made under different electrospinning conditions. Mean fiber diameter, pore characterization and surface roughness of the PAN nano-fibrous mats were determined using image processing technique. In order to evaluate the surface tension of the fabricated mats, water contact angle was measured. The leukocyte removal performance, erythrocytes recovery percent and hemolysis rate of the nano-fibrous mats were compared. The effectiveness of nano-fibrous mats in removing leukocyte was established using both scanning electron microscope and optical microscope. Results showed that for given weight, the fabricated nano-fibrous mats were not only more efficient but also more cost-effective than their commercial counterparts. Results confirmed that changes in mean fiber diameter, the number of layer and weight of each layer in the absence of any chemical reaction or physical surface modification, the fabricated nano-fibrous mats were able to remove 5-log of leukocytes. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 1759-1769, 2018. © 2017 Wiley Periodicals, Inc.
Davoudi, Amin; Razavi, Sayed Alireza; Mosaddeghmehrjardi, Mohammad Hossein; Tabrizizadeh, Mehdi
2015-01-01
Introduction: Successful endodontic treatment depends on elimination of the microorganisms through chemomechanical debridement. The aim of this in vitro study was to evaluate the effectiveness of Fragaria vesca (wild strawberry) extract (FVE) on the removal of smear layer (SL). Methods and Materials: In this analytical-observational study, 40 extracted mandibular and maxillary human teeth were selected. After canal preparation with standard step-back technique, the teeth were randomly divided into 4 groups according to the irrigation solution: saline (negative control), 5.25% NaOCl+EDTA (positive control), FVE and FVE+EDTA. The teeth were split longitudinally so that scanning electron microscopy (SEM) photomicrographs could be taken to evaluate the amount of remnant SL in coronal, middle and apical thirds. The data were analyzed statistically by the Kruskal-Wallis and Mann Whitney U tests and the level of significance was set at 0.05. Results: Significant differences were found among the groups (P<0.001). The use of NaOCl+EDTA was the most effective regimen for removing the SL followed by FVE+EDTA. FVE alone was significantly more effective than saline (P<0.001). Conclusion: FVE with and without EDTA could effectively remove the smear layer; however, compared to NaOCl group it was less effective. PMID:26526069
NASA Technical Reports Server (NTRS)
Spear, W. Steve; Dursch, Harry W.
1992-01-01
Following LDEF retrieval, a number of studies were made of mechanical hardware and structure flown on the LDEF. The primary objectives are to determine the effects of long term space exposure on (1) mechanisms either used on LDEF or as part of individual experiments; (2) LDEF structural components; and (3) fasteners. Results from examination and testing of LDEF structure, fasteners, LDEF end support beam, environment exposure control canisters, experiment tray clamps, LDEF grapple fixtures, and viscous damper are presented. The most significant finding is the absence of space exposure related cold welding. The instances of seizure or removal difficulties initially attributed to cold welding were shown to have resulted from installation galling damage or improper removal techniques. Widespread difficulties encountered with removal of stainless steel fasteners underscore the need for effective thread lubrication schemes to ensure successful application of proposed orbital replacement units onboard Space Station Freedom.
Jang, Sung-Chan; Kang, Sung-Min; Kim, Gi Yong; Rethinasabapathy, Muruganantham; Haldorai, Yuvaraj; Lee, Ilsong; Han, Young-Kyu; Renshaw, Joanna C; Roh, Changhyun; Huh, Yun Suk
2018-06-12
In this work, we elucidate polymer-layered hollow Prussian blue-coated magnetic nanocomposites as an adsorbent to remove radioactive cesium from environmentally contaminated water. To do this, Fe₃O₄ nanoparticles prepared using a coprecipitation method were thickly covered with a layer of cationic polymer to attach hollow Prussian blue through a self-assembly process. The as-synthesized adsorbent was confirmed through various analytical techniques. The adsorbent showed a high surface area (166.16 m²/g) with an excellent cesium adsorbent capacity and removal efficiency of 32.8 mg/g and 99.69%, respectively. Moreover, the superparamagnetism allows effective recovery of the adsorbent using an external magnetic field after the adsorption process. Therefore, the magnetic adsorbent with a high adsorption efficiency and convenient recovery is expected to be effectively used for rapid remediation of radioactive contamination.
Brummelhuis, Walter J; Joles, Jaap A; Stam, Jord C; Adams, Hendrik; Goldschmeding, Roel; Detmers, Frank J; El Khattabi, Mohamed; Maassen, Bram T; Verrips, C Theo; Braam, Branko
2010-08-01
Staphylococcus aureus produces the superantigen toxic shock syndrome toxin 1 (TSST-1). When the bacterium invades the human circulation, this toxin can induce life-threatening gram-positive sepsis. Current sepsis treatment does not remove bacterial toxins. Variable domains of llama heavy-chain antibodies (VHH) against toxic shock syndrome toxin 1 ([alpha]-TSST-1 VHH) were previously found to be effective in vitro. We hypothesized that removing TSST-1 with [alpha]-TSST-1 VHH hemofiltration filters would ameliorate experimental sepsis in pigs. After assessing in vitro whether timely removing TSST-1 interrupted TSST-1-induced mononuclear cell TNF-[alpha] production, VHH-coated filters were applied in a porcine sepsis model. Clinical course, survival, plasma interferon [gamma], and TSST-1 levels were similar with and without VHH-coated filters as were TSST-1 concentrations before and after the VHH filter. Plasma TSST-1 levels were much lower than anticipated from the distribution of the amount of infused TSST-1, suggesting compartmentalization to space or adhesion to surface not accessible to hemofiltration or pheresis techniques. Removing TSST-1 from plasma was feasible in vitro. However, the [alpha]-TSST-1 VHH adsorption filter-based technique was ineffective in vivo, indicating that improvement of VHH-based hemofiltration is required. Sequestration likely prevented the adequate removal of TSST-1. The latter warrants further investigation of TSST-1 distribution and clearance in vivo.
NASA Astrophysics Data System (ADS)
Zhang, Hongshen; Chen, Ming
2015-11-01
The recovery and utilization of automotive plastics are a global concern because of the increasing number of end-of-life vehicles. In-depth studies on technologies for the removal of coatings from automotive plastics can contribute to the high value-added levels of the recycling and utilization of automotive plastic. The liquid waste generated by removing chemical paint by using traditional methods is difficult to handle and readily produces secondary pollution. Therefore, new, clean, and highly efficient techniques of paint removal must be developed. In this article, a method of coating removal from passenger-vehicle plastics was generated based on high-pressure water jet technology to facilitate the recycling of these plastics. The established technology was theoretically analyzed, numerically simulated, and experimentally studied. The high-pressure water jet equipment for the removal of automotive-plastic coatings was constructed through research and testing, and the detailed experiments on coating removal rate were performed by using this equipment. The results showed that high-pressure water jet technology can effectively remove coatings on the surfaces of passenger-vehicle plastics. The research also revealed that the coating removal rate increased as jet pressure ( P) increased and then decreased when jet moving speed ( Vn) increased. The rate decreased as the distance from nozzle to work piece ( S nw ) and the nozzle angle ( Φ) increased. The mathematical model for the rate of removal of coatings from bumper surfaces by water jet was derived based on the experiment data and can effectively predict coating removal rate under different operating conditions.
Assessment of active methods for removal of LEO debris
NASA Astrophysics Data System (ADS)
Hakima, Houman; Emami, M. Reza
2018-03-01
This paper investigates the applicability of five active methods for removal of large low Earth orbit debris. The removal methods, namely net, laser, electrodynamic tether, ion beam shepherd, and robotic arm, are selected based on a set of high-level space mission constraints. Mission level criteria are then utilized to assess the performance of each redirection method in light of the results obtained from a Monte Carlo simulation. The simulation provides an insight into the removal time, performance robustness, and propellant mass criteria for the targeted debris range. The remaining attributes are quantified based on the models provided in the literature, which take into account several important parameters pertaining to each removal method. The means of assigning attributes to each assessment criterion is discussed in detail. A systematic comparison is performed using two different assessment schemes: Analytical Hierarchy Process and utility-based approach. A third assessment technique, namely the potential-loss analysis, is utilized to highlight the effect of risks in each removal methods.
Atmospheric effects on radiation measurements
NASA Technical Reports Server (NTRS)
Jurica, G. M.
1973-01-01
Two essentially distinct regions of the electromagnetic spectrum are discussed: (1) the scattering region in which the radiation energy is provided by the incident solar flux; and (2) the infrared region in which emission by the earth's surface and atmospheric gases supply radiative energy. In each of these spectral regions the atmosphere performs its dual function with respect to a remote sensing measurement of surface properties. The atmosphere acts both as a filter and as a noise generator removing and obscuring sought after information. Nevertheless, with proper application of concepts such as have been considered, it will be possible to remove these unwanted atmospheric effects and to improve identification techniques being developed.
NASA Astrophysics Data System (ADS)
Ihsani, V.; Nursasongko, B.; Djauharie, N.
2017-08-01
The concept of conserving healthy tooth structures during cavity preparation has gained popularity with chemo-mechanical caries removal. This study compared three methods of caries removal using: a chemo-mechanical caries removal papain gel; Papacarie® (these contain natural ingredients, mainly papain enzyme); and mechanical preparation with a bur rotary instrument. The purpose of this study was to compare affected dentin micro-hardness after removal of infected dentin with mechanical and chemo-mechanical techniques. Twenty-seven permanent molar teeth were randomly divided into three groups receiving removal of infected dentin. These were: Group 1: chemo-mechanical technique using papain gel; Group 2: chemo-mechanical technique using Papacarie® Group 3: mechanical technique using a bur rotary instrument. Each group was tested using Knoop Micro-hardness tester, and the data were submitted to one way ANOVA and Post-hoc Tukey test. There is a significant difference between Groups 1 and 3, and Groups 2 and 3, p = 0.000. However, there is no significant difference between Groups 1 and 2, p = 1.000. Affected dentin micro-hardness after removal of infected dentin with a bur rotary tool is higher than after use of the papain gel or Papacarie®. Affected dentin micro-hardness after removal of infected dentin with Papacarie® and papain gel give almost the same result.
Assessing LiDAR elevation data for KDOT applications : [technical summary].
DOT National Transportation Integrated Search
2013-02-01
LiDAR-based elevation surveys : are a cost-effective means for : mapping topography over large : areas. LiDAR surveys use an : airplane-mounted or ground-based : laser radar unit to scan terrain. : Post-processing techniques are : applied to remove v...
Laser balancing system for high material removal rates
NASA Technical Reports Server (NTRS)
Jones, M. G.; Georgalas, G.; Ortiz, A. L.
1984-01-01
A laser technique to remove material in excess of 10 mg/sec from a spinning rotor is described. This material removal rate is 20 times greater than previously reported for a surface speed of 30 m/sec. Material removal enhancement was achieved by steering a focused laser beam with moving optics to increase the time of laser energy interaction with a particular location on the circumferential surface of a spinning rotor. A neodymium:yttrium aluminum garnet (Nd:YAG) pulse laser was used in this work to evaluate material removal for carbon steel, 347 stainless steel, Inconal 718, and titanium 6-4. This technique is applicable to dynamic laser balancing.
Signal and noise level estimation for narrow spectral width returns observed by the Indian MST radar
NASA Astrophysics Data System (ADS)
Hooper, D. A.
1999-07-01
Use is made of five sets of multibeam observations of the lower atmosphere made by the Indian mesosphere-stratosphere-troposphere (MST) radar. Two aspects of signal processing which can lead to serious underestimates of the signal-to-noise ratio are considered. First, a comparison is made of the effects of different data weighting windows applied to the inphase and quadrature components of the radar return samples prior to Fourier transformation. The relatively high degree of spectral leakage associated with the rectangular and Hamming windows can give rise to overestimates of the noise levels by up to 28 dB for the strongest signals. Use of the Hanning window is found to be the most appropriate for these particular data. Second, a technique for removing systematic dc biases from the data in the time domain is compared with the more well-known practice of correction in the frequency domain. The latter technique, which is often used to remove the effects of ground clutter, is shown to be particularly inappropriate for the characteristically narrow spectral width signals observed by the Indian MST radar. For cases of near-zero Doppler shift it can remove up to 30 dB of signal information. The consequences of noise and signal level discrepancies for studies of refractivity structures are discussed. It is shown that neither problem has a significant effect on Doppler shift or spectral width estimates.
Tan, Yuyong; Huo, Jirong; Liu, Deliang
2017-11-01
Gastrointestinal submucosal tumors (SMTs) have been increasingly identified via the use of endoscopic ultrasonography, and removal is often recommended for SMTs that are >2 cm in diameter or symptomatic. Submucosal tunneling endoscopic resection (STER), also known as submucosal endoscopic tumor resection, endoscopic submucosal tunnel dissection or tunneling endoscopic muscularis dissection, is a novel endoscopic technique for treating gastrointestinal SMTs originating from the muscularis propria layer, and has been demonstrated to be effective in the removal of SMTs with a decreased rate of recurrence by clinical studies. STER may be performed for patients with esophageal or cardia SMTs, and its application has expanded beyond these types of SMTs due to modifications to the technique. The present study reviewed the applications, procedure, efficacy and complications associated with STER.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menapace, J A; Schaffers, K I; Bayramian, A J
2008-02-26
Advanced magnetorheological finishing (MRF) techniques have been applied to Ti:sapphire crystals to compensate for sub-millimeter lattice distortions that occur during the crystal growing process. Precise optical corrections are made by imprinting topographical structure onto the crystal surfaces to cancel out the effects of the lattice distortion in the transmitted wavefront. This novel technique significantly improves the optical quality for crystals of this type and sets the stage for increasing the availability of high-quality large-aperture sapphire and Ti:sapphire optics in critical applications.
Bioremediation techniques applied to aqueous media contaminated with mercury.
Velásquez-Riaño, Möritz; Benavides-Otaya, Holman D
2016-12-01
In recent years, the environmental and human health impacts of mercury contamination have driven the search for alternative, eco-efficient techniques different from the traditional physicochemical methods for treating this metal. One of these alternative processes is bioremediation. A comprehensive analysis of the different variables that can affect this process is presented. It focuses on determining the effectiveness of different techniques of bioremediation, with a specific consideration of three variables: the removal percentage, time needed for bioremediation and initial concentration of mercury to be treated in an aqueous medium.
Falciglia, Pietro P; Ingrao, Carlo; De Guidi, Guido; Catalfo, Alfio; Finocchiaro, Guglielmo; Farina, Marcello; Liali, Maria; Lorenzano, Giuseppe; Valastro, Gaetano; Vagliasindi, Federico G A
2018-04-01
The potential ability of microwave heating (MWH) for the remediation of marine sediments affected by severe hydrocarbon (HC) contamination was investigated. Decontamination effectiveness and environmental sustainability through a comparative Life Cycle Assessment (LCA) were addressed. Main results revealed that the application of a 650-W MWH treatment resulted in a rapid (15min) HC removal. A citric acid (CA) dose of 0.1M led to enhanced-HC removals of 76.9, 96.5 and 99.7% after 5, 10 and 15min of MW irradiation, respectively. The increase in CA dose to 0.2M resulted in a shorter successful remediation time of 10min. The exponential kinetic model adopted showed a good correlation with the experimental data with R 2 values in the 0.913-0.987 range. The nature of the MW treatment was shown to differently influence the HC fraction concentration after the irradiation process. Achieved HC removals in such a short remediation time are hardly possible by other clean-up techniques, making the studied treatment a potential excellent choice. Removal mechanisms, which allowed the enhanced-MWH to operate as a highly effective multi-step technique (pure thermal desorption+chemical washing), undoubtedly represent a key factor in the whole remediation process. The LCA highlighted that the MW technology is the most environmentally sustainable alternative for sediment decontamination applications, with a total damage, which was 75.74% lower than that associated with the EK (0.0503pt). Copyright © 2017 Elsevier B.V. All rights reserved.
Cleaning Genesis Solar Wind Collectors with Ultrapure Water: Residual Contaminant Particle Analysis
NASA Technical Reports Server (NTRS)
Allton, J. H.; Wentworth, S. J.; Rodriquez, M. C.; Calaway, M. J.
2008-01-01
Additional experience has been gained in removing contaminant particles from the surface of Genesis solar wind collectors fragments by using megasonically activated ultrapure water (UPW)[1]. The curatorial facility has cleaned six of the eight array collector material types to date: silicon (Si), sapphire (SAP), silicon-on-sapphire (SOS), diamond-like carbon-on-silicon (DOS), gold-on-sapphire (AuOS), and germanium (Ge). Here we make estimates of cleaning effectiveness using image analysis of particle size distributions and an SEM/EDS reconnaissance of particle chemistry on the surface of UPW-cleaned silicon fragments (Fig. 1). Other particle removal techniques are reported by [2] and initial assessment of molecular film removal is reported by [3].
[Effects of understory removal on soil greenhouse gas emissions in Carya cathayensis stands].
Liu, Juan; Chen, Xue-shuang; Wu, Jia-sen; Jiang, Pei-kun; Zhou, Guo-mo; Li, Yong-fu
2015-03-01
CO2, N2O and CH4 are important greenhouse gases, and soils in forest ecosystems are their important sources. Carya cathayensis is a unique tree species with seeds used for high-grade dry fruit and oil production. Understory vegetation management plays an important role in soil greenhouse gases emission of Carya cathayensis stands. A one-year in situ experiment was conducted to study the effects of understory removal on soil CO2, N2O and CH4 emissions in C. cathayensis plantation by closed static chamber technique and gas chromatography method. Soil CO2 flux had a similar seasonal trend in the understory removal and preservation treatments, which was high in summer and autumn, and low in winter and spring. N2O emission occurred mainly in summer, while CH4 emission showed no seasonal trend. Understory removal significantly decreased soil CO, emission, increased N2O emission and CH4 uptake, but had no significant effect on soil water soluble organic carbon and microbial biomass carbon. The global warming potential of soil greenhouse gases emitted in the understory removal. treatment was 15.12 t CO2-e . hm-2 a-1, which was significantly lower than that in understory preservation treatment (17.04 t CO2-e . hm-2 . a-1).
Magnesium incorporated bentonite clay for defluoridation of drinking water.
Thakre, Dilip; Rayalu, Sadhana; Kawade, Raju; Meshram, Siddharth; Subrt, J; Labhsetwar, Nitin
2010-08-15
Low cost bentonite clay was chemically modified using magnesium chloride in order to enhance its fluoride removal capacity. The magnesium incorporated bentonite (MB) was characterized by using XRD and SEM techniques. Batch adsorption experiments were conducted to study and optimize various operational parameters such as adsorbent dose, contact time, pH, effect of co-ions and initial fluoride concentration. It was observed that the MB works effectively over wide range of pH and showed a maximum fluoride removal capacity of 2.26 mgg(-1) at an initial fluoride concentration of 5 mg L(-1), which is much better than the unmodified bentonite. The experimental data fitted well into Langmuir adsorption isotherm and follows pseudo-first-order kinetics. Thermodynamic study suggests that fluoride adsorption on MB is reasonably spontaneous and an endothermic process. MB showed significantly high fluoride removal in synthetic water as compared to field water. Desorption study of MB suggest that almost all the loaded fluoride was desorbed ( approximately 97%) using 1M NaOH solution however maximum fluoride removal decreases from 95.47 to 73 (%) after regeneration. From the experimental results, it may be inferred that chemical modification enhances the fluoride removal efficiency of bentonite and it works as an effective adsorbent for defluoridation of water. Copyright 2010 Elsevier B.V. All rights reserved.
Fu, Rongbing; Yang, Yingpin; Xu, Zhen; Zhang, Xian; Guo, Xiaopin; Bi, Dongsu
2015-11-01
In this study, the synthesis and characterization of sepiolite-supported nanoscale zero-valent iron particles (S-NZVI) was investigated for the adsorption/reduction of Cr(VI) and Pb(II) ions. Nanoscale zero-valent iron (NZVI) supported on sepiolite was successfully used to remove Cr(VI) and Pb(II) from groundwater with high efficiency. The removal mechanism was proposed as a two-step interaction including both the physical adsorption of Cr(VI) and Pb(II) on the surface or inner layers of the sepiolite-supported NZVI particles and the subsequent reduction of Cr(VI) to Cr(III) and Pb(II) to Pb(0) by NZVI. The immobilization of the NZVI particles on the surface of sepiolite could help to overcome the disadvantage of NZVI particles, which have strong tendency to agglomerate into larger particles, resulting in an adverse effect on both the effective surface area and reaction performance. The techniques of XRD, XPS, BET, Zeta potential, and TEM were used to characterize the S-NZVI and interaction between S-NZVI and heavy metals. The appropriate S-NZVI dosage was 1.6 g L(-1). The removal efficiency of Cr(VI) and Pb(II) by S-NZVI was not affected to any considerable extent by the presence of co-existing ions, such as H2PO4(-), SiO3(2-), Ca(2+) and HCO3(-). The Cr(VI) and Pb(II) removal kinetics followed a pseudo-first-order rate expression, and both Langmuir isotherm model and Freundlich isotherm model were proposed. The results suggested that supporting NZVI on sepiolite had the potential to become a promising technique for in situ heavy metal-contaminated groundwater remediation. Copyright © 2015 Elsevier Ltd. All rights reserved.
Nitrate removal from drinking water with a focus on biological methods: a review.
Rezvani, Fariba; Sarrafzadeh, Mohammad-Hossein; Ebrahimi, Sirous; Oh, Hee-Mock
2017-05-31
This article summarizes several developed and industrial technologies for nitrate removal from drinking water, including physicochemical and biological techniques, with a focus on autotrophic nitrate removal. Approaches are primarily classified into separation-based and elimination-based methods according to the fate of the nitrate in water treatment. Biological denitrification as a cost-effective and promising method of biological nitrate elimination is reviewed in terms of its removal process, applicability, efficiency, and associated disadvantages. The various pathways during biological nitrate removal, including assimilatory and dissimilatory nitrate reduction, are also explained. A comparative study was carried out to provide a better understanding of the advantages and disadvantages of autotrophic and heterotrophic denitrification. Sulfur-based and hydrogen-based denitrifications, which are the most common autotrophic processes of nitrate removal, are reviewed with the aim of presenting the salient features of hydrogenotrophic denitrification along with some drawbacks of the technology and research areas in which it could be used but currently is not. The application of algae-based water treatment is also introduced as a nature-inspired approach that may broaden future horizons of nitrate removal technology.
Improved grid-noise removal in single-frame digital moiré 3D shape measurement
NASA Astrophysics Data System (ADS)
Mohammadi, Fatemeh; Kofman, Jonathan
2016-11-01
A single-frame grid-noise removal technique was developed for application in single-frame digital-moiré 3D shape measurement. The ability of the stationary wavelet transform (SWT) to prevent oscillation artifacts near discontinuities, and the ability of the Fourier transform (FFT) applied to wavelet coefficients to separate grid-noise from useful image information, were combined in a new technique, SWT-FFT, to remove grid-noise from moiré-pattern images generated by digital moiré. In comparison to previous grid-noise removal techniques in moiré, SWT-FFT avoids the requirement for mechanical translation of optical components and capture of multiple frames, to enable single-frame moiré-based measurement. Experiments using FFT, Discrete Wavelet Transform (DWT), DWT-FFT, and SWT-FFT were performed on moiré-pattern images containing grid noise, generated by digital moiré, for several test objects. SWT-FFT had the best performance in removing high-frequency grid-noise, both straight and curved lines, minimizing artifacts, and preserving the moiré pattern without blurring and degradation. SWT-FFT also had the lowest noise amplitude in the reconstructed height and lowest roughness index for all test objects, indicating best grid-noise removal in comparison to the other techniques.
Kim, C.S.; Bloom, N.S.; Rytuba, J.J.; Brown, Gordon E.
2003-01-01
Determining the chemical speciation of mercury in contaminated mining and industrial environments is essential for predicting its solubility, transport behavior, and potential bioavailability as well as for designing effective remediation strategies. In this study, two techniques for determining Hg speciation-X-ray absorption fine structure (XAFS) spectroscopy and sequential chemical extractions (SCE)-are independently applied to a set of samples with Hg concentrations ranging from 132 to 7539 mg/kg to determine if the two techniques provide comparable Hg speciation results. Generally, the proportions of insoluble HgS (cinnabar, metacinnabar) and HgSe identified by XAFS correlate well with the proportion of Hg removed in the aqua regia extraction demonstrated to remove HgS and HgSe. Statistically significant (> 10%) differences are observed however in samples containing more soluble Hg-containing phases (HgCl2, HgO, Hg3S2O 4). Such differences may be related to matrix, particle size, or crystallinity effects, which could affect the apparent solubility of Hg phases present. In more highly concentrated samples, microscopy techniques can help characterize the Hg-bearing species in complex multiphase natural samples.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nakashima, Y., E-mail: yuta-n@mech.kumamoto-u.ac.jp; Graduate School of Science and Engineering, Yamaguchi University, 2-16-1 Tokiwadai, Ube 755-8611; Tsusu, K.
2014-06-15
Here, we sought to develop a cell culture surface conversion technique that would not damage living cells. An alginate thin film, formed on a glass plate by spin coating of sodium alginate solution and dipping into calcium chloride solution, was used to inhibit adhesion of cells. The film could be removed by ethylenediaminetetraacetate (EDTA) at any time during cell culture, permitting observation of cellular responses to conversion of the culture surface in real time. Additionally, we demonstrated the validity of the alginate thin film coating method and the performance of the film. The thickness of the alginate thin film wasmore » controlled by varying the rotation speed during spin coating. Moreover, the alginate thin film completely inhibited the adhesion of cultured cells to the culture surface, irrespective of the thickness of the film. When the alginate thin film was removed from the culture surface by EDTA, the cultured cells adhered to the culture surface, and their morphology changed. Finally, we achieved effective differentiation of C2C12 myoblasts into myotube cells by cell culture on the convertible culture surface, demonstrating the utility of our novel technique.« less
Improvements in lung lavage to increase its effectiveness in removing inhaled radionuclides
DOE Office of Scientific and Technical Information (OSTI.GOV)
Muggenburg, B.A.; Guilmette, R.A.; Romero, L.M.
Lung lavage has been shown to be an effective method to remove insoluble radionuclides deposited and retained in the lung, but the treatment has been limited to the effective removal of only about 50% of the retained material. Reported here is change in lavage technique that slightly increases the effectiveness and the addition of high-frequency chest wall oscillation. The latter increased the effectiveness of the lavage procedure but also caused significant physiological complications. These studies were conducted in adult male and female beagles. The aerosol in the first study was {sup 239}PuO{sub 2} heat-treated at 850{degrees}C, obtained as powder frommore » a commercial V-blending process. The dogs briefly inhaled the aerosol per nasi. The tissue content at death and the amount of {sup 239}Pu excreted and in the recovered lung lavage fluid was determined by radiochemical methods{sup 5}. These values were used to reconstruct the initial pulmonary burden of {sup 239} and the amount of {sup 239}Pu removed by lavage. In the second study, with the HFCWO, the aerosol was {sup 85}Sr fused in aluminosilicate particles. The IPB of {sup 85}Sr was determined by whole-body counting. The excreta and recovered lung lavage fluids were also assayed for {sup 85}Sr activity.« less
Palliative effects of H2 on SOFCs operating with carbon containing fuels
NASA Astrophysics Data System (ADS)
Reeping, Kyle W.; Bohn, Jessie M.; Walker, Robert A.
2017-12-01
Chlorine can accelerate degradation of solid oxide fuel cell (SOFC) Ni-based anodes operating on carbon containing fuels through several different mechanisms. However, supplementing the fuel with a small percentage of excess molecular hydrogen effectively masks the degradation to the catalytic activity of the Ni and carbon fuel cracking reaction reactions. Experiments described in this work explore the chemistry behind the "palliative" effect of hydrogen on SOFCs operating with chlorine-contaminated, carbon-containing fuels using a suite of independent, complementary techniques. Operando Raman spectroscopy is used to monitor carbon accumulation and, by inference, Ni catalytic activity while electrochemical techniques including electrochemical impedance spectroscopy and voltammetry are used to monitor overall cell performance. Briefly, hydrogen not only completely hides degradation observed with chlorine-contaminated carbon-containing fuels, but also actively removes adsorbed chlorine from the surface of the Ni, allowing for the methane cracking reaction to continue, albeit at a slower rate. When hydrogen is removed from the fuel stream the cell fails immediately due to chlorine occupation of methane/biogas reaction sites.
Sharma, Swati; Tiwari, Sakshi; Hasan, Abshar; Saxena, Varun; Pandey, Lalit M
2018-04-01
Remediation of heavy metal-contaminated soils has been drawing our attention toward it for quite some time now and a need for developing new methods toward reclamation has come up as the need of the hour. Conventional methods of heavy metal-contaminated soil remediation have been in use for decades and have shown great results, but they have their own setbacks. The chemical and physical techniques when used singularly generally generate by-products (toxic sludge or pollutants) and are not cost-effective, while the biological process is very slow and time-consuming. Hence to overcome them, an amalgamation of two or more techniques is being used. In view of the facts, new methods of biosorption, nanoremediation as well as microbial fuel cell techniques have been developed, which utilize the metabolic activities of microorganisms for bioremediation purpose. These are cost-effective and efficient methods of remediation, which are now becoming an integral part of all environmental and bioresource technology. In this contribution, we have highlighted various augmentations in physical, chemical, and biological methods for the remediation of heavy metal-contaminated soils, weighing up their pros and cons. Further, we have discussed the amalgamation of the above techniques such as physiochemical and physiobiological methods with recent literature for the removal of heavy metals from the contaminated soils. These combinations have showed synergetic effects with a many fold increase in removal efficiency of heavy metals along with economic feasibility.
Plasma Sterilization: New Epoch in Medical Textiles
NASA Astrophysics Data System (ADS)
Senthilkumar, P.; Arun, N.; Vigneswaran, C.
2015-04-01
Clothing is perceived to be second skin to the human body since it is in close contact with the human skin most of the times. In hospitals, use of textile materials in different forms and sterilization of these materials is an essential requirement for preventing spread of germs. The need for appropriate disinfection and sterilization techniques is of paramount importance. There has been a continuous demand for novel sterilization techniques appropriate for use on various textile materials as the existing sterilization techniques suffer from various technical and economical drawbacks. Plasma sterilization is the alternative method, which is friendlier and more effective on the wide spectrum of prokaryotic and eukaryotic microorganisms. Basically, the main inactivation factors for cells exposed to plasma are heat, UV radiation and various reactive species. Plasma exposure can kill micro-organisms on a surface in addition to removing adsorbed monolayer of surface contaminants. Advantages of plasma surface treatment are removal of contaminants from the surface, change in the surface energy and sterilization of the surface. Plasma sterilization aims to kill and/or remove all micro-organisms which may cause infection of humans or animals, or which can cause spoilage of foods or other goods. This review paper emphasizes necessity for sterilization, essentials of sterilization, mechanism of plasma sterilization and the parameters influencing it.
Thermal management of VECSELs by front surface direct liquid cooling
NASA Astrophysics Data System (ADS)
Smyth, Conor J. C.; Mirkhanov, Shamil; Quarterman, Adrian H.; Wilcox, Keith G.
2016-03-01
Efficient thermal management is vital for VECSELs, affecting the output power and several aspects of performance of the device. Presently there exist two distinct methods of effective thermal management which both possess their merits and disadvantages. Substrate removal of the VECSEL gain chip has proved a successful method in devices emitting at a wavelength near 1μm. However for other wavelengths the substrate removal technique has proved less effective primarily due to the thermal impedance of the distributed Bragg reflectors. The second method of thermal management involves the use of crystalline heat spreaders bonded to the gain chip surface. Although this is an effective thermal management scheme, the disadvantages are additional loss and the etalon effect that filters the gain spectrum, making mode locking more difficult and normally resulting in multiple peaks in the spectrum. There are considerable disadvantages associated with both methods attributed to heatspreader cost and sample processing. It is for these reasons that a proposed alternative, front surface liquid cooling, has been investigated in this project. Direct liquid cooling involves flowing a temperature-controlled liquid over the sample's surface. In this project COMSOL was used to model surface liquid cooling of a VECSEL sample in order to investigate and compare its potential thermal management with current standard thermal management techniques. Based on modelling, experiments were carried out in order to evaluate the performance of the technique. While modelling suggests that this is potentially a mid-performance low cost alternative to existing techniques, experimental measurements to date do not reflect the performance predicted from modelling.
INFLUENCE OF AGING AND PH ON DISSOLUTION KINETICS AND STABILITY OF PHROMORPHITE
In-situ, immobilization of metal contaminates in soil systems shows great potential as a cost-effective and environmemtally sound remediation technique. Pb contaminated soils are typically removed from site and replaced with clean soil at great costs. However, innovative techno...
Hu, Fei; Cheng, Yayun; Gui, Liangqi; Wu, Liang; Zhang, Xinyi; Peng, Xiaohui; Su, Jinlong
2016-11-01
The polarization properties of thermal millimeter-wave emission capture inherent information of objects, e.g., material composition, shape, and surface features. In this paper, a polarization-based material-classification technique using passive millimeter-wave polarimetric imagery is presented. Linear polarization ratio (LPR) is created to be a new feature discriminator that is sensitive to material type and to remove the reflected ambient radiation effect. The LPR characteristics of several common natural and artificial materials are investigated by theoretical and experimental analysis. Based on a priori information about LPR characteristics, the optimal range of incident angle and the classification criterion are discussed. Simulation and measurement results indicate that the presented classification technique is effective for distinguishing between metals and dielectrics. This technique suggests possible applications for outdoor metal target detection in open scenes.
NASA Astrophysics Data System (ADS)
Cosano, Daniel; Esquinas, Carlos; Jiménez-Sanchidrián, César; Ruiz, José Rafael
2016-02-01
Calcining magnesium/aluminium layered double hydroxides (Mg/Al LDHs) at 450 °C provides excellent sorbents for removing cyanide from aqueous solutions. The process is based on the "memory effect" of LDHs; thus, rehydrating a calcined LDH in an aqueous solution restores its initial structure. The process, which conforms to a first-order kinetics, was examined by Raman spectroscopy. The metal ratio of the LDH was found to have a crucial influence on the adsorption capacity of the resulting mixed oxide. In this work, Raman spectroscopy was for the first time use to monitor the adsorption process. Based on the results, this technique is an effective, expeditious choice for the intended purpose and affords in situ monitoring of the adsorption process. The target solids were characterized by using various instrumental techniques including X-ray diffraction spectroscopy, which confirmed the layered structure of the LDHs and the periclase-like structure of the mixed oxides obtained by calcination.
NASA Astrophysics Data System (ADS)
Son, Youn-Suk; Kim, Ki-Joon; Kim, Ji-Yong; Kim, Jo-Chun
2010-12-01
We applied a hybrid technique to assess the decomposition characteristics of ethylbenzene and toluene that annexed the catalyst technique with existing electron beam (EB) technology. The removal efficiency of ethylbenzene in the EB-catalyst hybrid turned out to be 30% greater than that of EB-only treatment. We concluded that ethylbenzene was decomposed more easily than toluene by EB irradiation. We compared the independent effects of the EB-catalyst hybrid and catalyst-only methods, and observed that the efficiency of the EB-catalyst hybrid demonstrated approximately 6% improvement for decomposing toluene and 20% improvement for decomposing ethylbenzene. The G-values for ethylbenzene increased with initial concentration and reactor type: for example, the G-values by reactor type at 2800 ppmC were 7.5-10.9 (EB-only) and 12.9-25.7 (EB-catalyst hybrid). We also observed a significant decrease in by-products as well as in the removal efficiencies associated with the EB-catalyst hybrid technique.
NASA Technical Reports Server (NTRS)
Maskew, B.
1979-01-01
The description of the modified code includes details of a doublet subpanel technique in which panels that are close to a velocity calculation point are replaced by a subpanel set. This treatment gives the effect of a higher panel density without increasing the number of unknowns. In particular, the technique removes the close approach problem of the earlier singularity model in which distortions occur in the detailed pressure calculation near panel corners. Removal of this problem allowed a complete wake relaxation and roll-up iterative procedure to be installed in the code. The geometry package developed for the new technique and also for the more general configurations is based on a multiple patch scheme. Each patch has a regular array of panels, but arbitrary relationships are allowed between neighboring panels at the edges of adjacent patches. This provides great versatility for treating general configurations.
Endophytic microorganisms--promising applications in bioremediation of greenhouse gases.
Stępniewska, Z; Kuźniar, A
2013-11-01
Bioremediation is a technique that uses microbial metabolism to remove pollutants. Various techniques and strategies of bioremediation (e.g., phytoremediation enhanced by endophytic microorganisms, rhizoremediation) can mainly be used to remove hazardous waste from the biosphere. During the last decade, this specific technique has emerged as a potential cleanup tool only for metal pollutants. This situation has changed recently as a possibility has appeared for bioremediation of other pollutants, for instance, volatile organic compounds, crude oils, and radionuclides. The mechanisms of bioremediation depend on the mobility, solubility, degradability, and bioavailability of contaminants. Biodegradation of pollutions is associated with microbial growth and metabolism, i.e., factors that have an impact on the process. Moreover, these factors have a great influence on degradation. As a result, recognition of natural microbial processes is indispensable for understanding the mechanisms of effective bioremediation. In this review, we have emphasized the occurrence of endophytic microorganisms and colonization of plants by endophytes. In addition, the role of enhanced bioremediation by endophytic bacteria and especially of phytoremediation is presented.
α-keratin/Alginate Biosorbent for Removal of Methylene Blue on Aqueous Solution in a Batch System
NASA Astrophysics Data System (ADS)
Fadillah, G.; Putri, E. N. K.; Febrianastuti, S.; Munawaroh, H.; Purnawan, C.; Wahyuningsih, S.
2018-03-01
Methylene Blue (MB) is a cationic dyes which is commonly used in textile industries for coloring agent. The precence of MB in water caused some negative effect on the environment and human health. Many common technologies such as membrane filtration, electrophoresis and adsorption have been widely empolyed for removal of MB in water, but the adsorption technique still has advantages than the others. In this study, removal of MB used a biosorbent α-keratin/alginate (KA). The biosorbent KA was prepared by using the encapsulation technique in CaCl2 2 % (w/v) solution. The biosorbent was characterized by Fourier Transform Infrared (FTIR) and Scanning Electron Microscope (SEM). The effect of composition of α-keratin and alginate, the pH of solution and contact time on the adsorption were investigated. The optimum adsorption of MB in aqueous solution was found at the composition of α-keratin and alginate of 1:2 (w/w), the pH at 5.0 and contact time at 4 hours. The adsorption of MB on KA biosorbent was comparatively higher than α-keratin and alginate only. Adsorption of MB dyes in aqueous solution followed the Langmuir adsorption isotherm, and the dynamic adsorption model could be described through a pseudo-second order kinetics.
Degradation of trichloroethylene in aqueous solution by calcium peroxide activated with ferrous ion.
Zhang, Xiang; Gu, Xiaogang; Lu, Shuguang; Miao, Zhouwei; Xu, Minhui; Fu, Xiaori; Qiu, Zhaofu; Sui, Qian
2015-03-02
The application of calcium peroxide (CaO2) activated with ferrous ion to stimulate the degradation of trichloroethylene (TCE) was investigated. The experimental results showed that TCE could be completely degraded in 5 min at a CaO2/Fe(II)/TCE molar ratio of 4/8/1. Probe compound tests demonstrated the presence of reactive oxygen species HO· and O2(-·) in CaO2/Fe(II) system, while scavenging tests indicated that HO· was the dominant active species responsible for TCE removal, and O2(-·) could promote TCE degradation in CaO2/Fe(II) system. In addition, the influences of initial solution pH and solution matrix were evaluated. It suggested that the elevation of initial solution pH suppressed TCE degradation. Cl(-) had significant scavenging effect on TCE removal, whereas HCO3(-) of high concentration showed favorable function. The influences of NO3(-) and SO4(2-) could be negligible, while natural organic matter (NOM) had a negative effect on TCE removal at a relatively high concentration. The results demonstrated that the technique of CaO2 activated with ferrous ion is a highly promising technique in in situ chemical oxidation (ISCO) remediation in TCE contaminated sites. Copyright © 2014. Published by Elsevier B.V.
Development of practical decontamination process for the removal of uranium from gravel.
Kim, Ilgook; Kim, Gye-Nam; Kim, Seung-Soo; Choi, Jong-Won
2018-01-01
In this study, a practical decontamination process was developed to remove uranium from gravel using a soil washing method. The effects of critical parameters including particle size, H 2 SO 4 concentration, temperature, and reaction time on uranium removal were evaluated. The optimal condition for two-stage washing of gravel was found to be particle size of 1-2 mm, 1.0 M H 2 SO 4 , temperature of 60°C, and reaction time of 3 h, which satisfied the required uranium concentration for self-disposal. Furthermore, most of the extracted uranium was removed from the waste solution by precipitation, implying that the treated solution can be reused as washing solution. These results clearly demonstrated that our proposed process can be indeed a practical technique to decontaminate uranium-polluted gravel.
[Novel resources utilization technique for rural domestic refuse].
Qiu, Cai-Di; He, Ruo; Chen, Song-Mei; Lou, Bin; Shen, Dong-Sheng
2009-03-15
In order to speed up rural domestic refuse resources utilization, intermittent aeration and continuous aeration were applied to treat rural domestic refuse after anaerobic fermentation. Three kinds of refuse were selected on base of fermentative age, i.e. three months, five months and seven months. Results showed that aeration could remove water and organic materials of the refuse effectively. Points of view on aeration, continuous aeration was better than intermittent aeration, and on the other side, water removal rate increased with ventilation and decreased with fermentative age in the condition of intermittent aeration. On organic materials removal point, it was affected by fermentative age significantly, i. e. increase of fermentative age could resulted in decrease in the removal efficiency. In conclusion, intermittent aeration of 0.06 m3/(min x m3) was considered to be feasible for treatment. The water removal efficiency of three months, five months and seven months fermentative age refuse could be up to 49.1%, 45.3% and 44.0%, and organic compound removal efficiency was 41.9%, 24.8% and 13.1%, respectively, after intermittent aeration for 21 d. Moreover, concentrated effect was presented on major nutrient ingredients, such as total nitrogen, phosphorus, and potassium during the aeration, which realized for resources utilization.
Endoscopic colloid cyst excision: surgical techniques and nuances.
Azab, Waleed Abdelfattah; Najibullah, Mustafa; Yosef, Waleed
2017-06-01
Endoscopic excision of colloid cysts is currently well established as a minimally invasive and highly effective technique that is associated with less morbidity in comparison to microsurgical resection. Operative charts and videos of patients undergoing endoscopic colloid cyst excision were retrieved from the senior author's database of endoscopic procedures and reviewed. This revealed nine trans-foraminal and three trans-septal procedures. Description of the surgical techniques was then formulated. Variation of the technique is based on the specific patho-anatomical features of the colloid cyst being resected. For the trans-foraminal approach, we think that the rotational technique is associated with a more complete removal of the cyst wall and consequently lower recurrence rate.
Ming, Tingzhen; de Richter, Renaud; Shen, Sheng; Caillol, Sylvain
2016-04-01
Even if humans stop discharging CO2 into the atmosphere, the average global temperature will still increase during this century. A lot of research has been devoted to prevent and reduce the amount of carbon dioxide (CO2) emissions in the atmosphere, in order to mitigate the effects of climate change. Carbon capture and sequestration (CCS) is one of the technologies that might help to limit emissions. In complement, direct CO2 removal from the atmosphere has been proposed after the emissions have occurred. But, the removal of all the excess anthropogenic atmospheric CO2 will not be enough, due to the fact that CO2 outgases from the ocean as its solubility is dependent of its atmospheric partial pressure. Bringing back the Earth average surface temperature to pre-industrial levels would require the removal of all previously emitted CO2. Thus, the atmospheric removal of other greenhouse gases is necessary. This article proposes a combination of disrupting techniques to transform nitrous oxide (N2O), the third most important greenhouse gas (GHG) in terms of current radiative forcing, which is harmful for the ozone layer and possesses quite high global warming potential. Although several scientific publications cite "greenhouse gas removal," to our knowledge, it is the first time innovative solutions are proposed to effectively remove N2O or other GHGs from the atmosphere other than CO2.
Maalouf, Lara; Zogheib, Carla; Naaman, Alfred
2013-03-01
Compare the efficiency in removing two calcium hydroxide [Ca(OH)2] preparations from root canal and apical third using single use syringe, ultrasonics and RinsEndo((®)) with saline solution. One hundred and eighty human singlerooted teeth were instrumented using ProTaper((®)) rotary system, divided into two groups according to Ca(OH)2 filling. A: Powder mixed with water, B: Pulpdent((®)). Each group was divided into three subgroups for the irrigation: A1, B1: Single use syringe; A2, B2: Ultrasonics; A3, B3: RinsEndo((®)). Teeth were split longitudinally, photographed and imported into Adobe Photoshop. The percentage ratios of Ca(OH)2 remaining in the canal and in the apical third were calculated. Data were statistically analyzed using 'ANOVA two-way' and 'univariate tests'. (a) Remnants of medicament were found in all teeth, (b) no statistically significant difference in the elimination of both Ca(OH)2 from the entire canal (p = 0.436), however, mixed powder was better eliminated from the apical third (p = 0.005), (c) no statistically significant difference among the irrigation techniques in the whole canal (p = 0.608), though, RinsEndo((®)) and ultrasonics were the most effective in cleaning the apical third (p = 0.032) when mixed powder was used. None of the techniques removed completely Ca(OH)2 from the canal. In the apical third, RinsEndo((®)) and ultrasonics were the most effective when mixed powder was used. Ca(OH)2, the most commonly used intracanal dressing, should be completely eliminated before the obturation to assure a good endodontic sealing. Based on the results of this study, RinsEndo((®)) and ultrasonics were the most effective in removal of Ca(OH)2 especially the powder mixed with water presentation.
Guo, Xiangjun; Miao, Hui; Li, Lei; Zhang, Shasha; Zhou, Dongyan; Lu, Yan; Wu, Ligeng
2014-09-08
Efforts to improve the efficacy of smear layer removal by applying irrigant activation at the final irrigation or by elevating the temperature of the irrigant have been reported. However, the combination of such activation protocols with 60 °C 3% sodium hypochlorite (NaOCl) has seldom been mentioned. The aim of this study was to compare the efficacy in smear layer removal of four different irrigation techniques combined with 60 °C 3% NaOCl and 17% EDTA. Fifty single-rooted teeth were randomly divided into five groups (n = 10) according to the irrigant agitation protocols used during chemomechanical preparation(Dentsply Maillefer, Ballaigues, Switzerland): a side-vented needle group, a ultrasonic irrigation (UI) group, a NaviTip FX group, an EndoActivator group, and a control group (no agitation). After each instrumentation, the root canals were irrigated with 1 mL of 3% NaOCl at 60 °C for 1 minute, and after the whole instrumentation, the root canals were rinsed with 1 mL of 17% EDTA for 1 minute. Both NaOCl and EDTA were activated with one of the five irrigation protocols. The efficacy of smear layer removal was scored at the apical, middle and coronal thirds. The Data were statistically analyzed using SAS version 9.2 for Windows (rank sum test for a randomised block design and ANOVA). No significant differences among the NaviTip FX group, EndoActivator group and control groups, and each of these groups showed a lower score than that of UI group (P < 0.05). Within each group, all three thirds were ranked in the following order: coronal > middle > apical (P < 0.05). In the coronal third, the NaviTip FX group was better than UI group. In the middle and apical third, the differences were not significant among any of the groups. Even without any activation, the combination of 60 °C 3% NaOCl and 17% EDTA could remove the smear layer effectively, similar to NaviTip FX or EndoActivator, and these three protocols were more effective than UI. However, regardless of different types of irrigation technique applied, complete removal of the smear layer was not achieved, particularly in the apical third.
NASA Technical Reports Server (NTRS)
Kim, Young-Joon; Pak, Kyung S.; Dunbar, R. Scott; Hsiao, S. Vincent; Callahan, Philip S.
2000-01-01
Planetary boundary layer (PBL) models are utilized to enhance directional ambiguity removal skill in scatterometer data processing. The ambiguity in wind direction retrieved from scatterometer measurements is removed with the aid of physical directional information obtained from PBL models. This technique is based on the observation that sea level pressure is scalar and its field is more coherent than the corresponding wind. An initial wind field obtained from the scatterometer measurements is used to derive a pressure field with a PBL model. After filtering small-scale noise in the derived pressure field, a wind field is generated with an inverted PBL model. This derived wind information is then used to remove wind vector ambiguities in the scatterometer data. It is found that the ambiguity removal skill can be improved when the new technique is used properly in conjunction with the median filter being used for scatterometer wind dealiasing at JPL. The new technique is applied to regions of cyclone systems which are important for accurate weather prediction but where the errors of ambiguity removal are often large.
Zhou, Zhongxing; Gao, Feng; Zhao, Huijuan; Zhang, Lixin
2011-03-01
Noise characterization through estimation of the noise power spectrum (NPS) is a central component of the evaluation of digital x-ray systems. Extensive works have been conducted to achieve accurate and precise measurement of NPS. One approach to improve the accuracy of the NPS measurement is to reduce the statistical variance of the NPS results by involving more data samples. However, this method is based on the assumption that the noise in a radiographic image is arising from stochastic processes. In the practical data, the artifactuals always superimpose on the stochastic noise as low-frequency background trends and prevent us from achieving accurate NPS. The purpose of this study was to investigate an appropriate background detrending technique to improve the accuracy of NPS estimation for digital x-ray systems. In order to achieve the optimal background detrending technique for NPS estimate, four methods for artifactuals removal were quantitatively studied and compared: (1) Subtraction of a low-pass-filtered version of the image, (2) subtraction of a 2-D first-order fit to the image, (3) subtraction of a 2-D second-order polynomial fit to the image, and (4) subtracting two uniform exposure images. In addition, background trend removal was separately applied within original region of interest or its partitioned sub-blocks for all four methods. The performance of background detrending techniques was compared according to the statistical variance of the NPS results and low-frequency systematic rise suppression. Among four methods, subtraction of a 2-D second-order polynomial fit to the image was most effective in low-frequency systematic rise suppression and variances reduction for NPS estimate according to the authors' digital x-ray system. Subtraction of a low-pass-filtered version of the image led to NPS variance increment above low-frequency components because of the side lobe effects of frequency response of the boxcar filtering function. Subtracting two uniform exposure images obtained the worst result on the smoothness of NPS curve, although it was effective in low-frequency systematic rise suppression. Subtraction of a 2-D first-order fit to the image was also identified effective for background detrending, but it was worse than subtraction of a 2-D second-order polynomial fit to the image according to the authors' digital x-ray system. As a result of this study, the authors verified that it is necessary and feasible to get better NPS estimate by appropriate background trend removal. Subtraction of a 2-D second-order polynomial fit to the image was the most appropriate technique for background detrending without consideration of processing time.
Effects of Angle of Attack and Velocity on Trailing Edge Noise
NASA Technical Reports Server (NTRS)
Hutcheson, Florence V.; Brooks, Thomas F.
2006-01-01
Trailing edge (TE) noise measurements for a NACA 63-215 airfoil model are presented, providing benchmark experimental data for a cambered airfoil. The effects of flow Mach number and angle of attack of the airfoil model with different TE bluntnesses are shown. Far-field noise spectra and directivity are obtained using a directional microphone array. Standard and diagonal removal beamforming techniques are evaluated employing tailored weighting functions for quantitatively accounting for the distributed line character of TE noise. Diagonal removal processing is used for the primary database as it successfully removes noise contaminates. Some TE noise predictions are reported to help interpret the data, with respect to flow speed, angle of attack, and TE bluntness on spectral shape and peak levels. Important findings include the validation of a TE noise directivity function for different airfoil angles of attack and the demonstration of the importance of the directivity function s convective amplification terms.
He, Junyong; Chen, Kai; Cai, Xingguo; Li, Yulian; Wang, Chengming; Zhang, Kaisheng; Jin, Zhen; Meng, Fanli; Wang, Xuguang; Kong, Lingtao; Liu, Jinhuai
2017-03-15
A biocompatible and novelly-defined adsorption membrane for rapid removal of fluoride was prepared. Both adsorption and membrane techniques were used in this research. Al(OH) 3 nanoparticles modified hydroxyapatite (Al-HAP) nanowires were developed and made into Al-HAP membrane. The adsorption data of Al-HAP adsorbent could be well described by Freundlich isotherm model while the adsorption kinetic followed pseudo-second-order model. The maximum of adsorption capacity was 93.84mg/g when the fluoride concentration was 200mg/L. The adsorption mechanism was anion exchanges and electrostatic interactions. The contribution rates of HAP nanowires and Al(OH) 3 nanoparticles in fluoride removal were 36.70% and 63.30%, respectively. The fixed-bed column test demonstrate that the Al-HAP was biocompatible and in a good stability during the process of water treatment. The fluoride removal abilities of Al-HAP membrane with 0.3mm thickness could reach 1568L/m 2 when fluoride concentrations were 5mg/L. This study indicated that the Al-HAP membrane could be developed into a very viable technology for highly effective removal of fluoride from drinking water. Copyright © 2016 Elsevier Inc. All rights reserved.
Removal of a glowing spot from an image tube using laser radiation.
NASA Technical Reports Server (NTRS)
Gurski, T. R.
1972-01-01
A troublesome problem with the Kron electronograph has been the presence of a white glowing spot on the glass wall of the tube adjacent to the focus electrode. The procedure followed to eliminate the spot was to operate in the dark and apply voltage only to the focused electrode. Ruby laser radiation was unfocused, and its position was shifted on the electrode between laser shots until an effect was observed. This technique for removing the glowing spot should be applicable to other electronic image tubes.
Farpour, Bijan; Browne, Alison; McClellan, BmedscKathyA; Billson, Frank A
2002-01-01
The purpose of this report is to describe a modified surgical iridocyclectomy technique and lensectomy for the removal of a recurrent iris cyst and a cataract in a child. A 3-year-old boy underwent uncomplicated standard iridocyclectomy for the removal of an enlarging congenital epidermal iris cyst. In the postoperative period, the cyst recurred. A second surgical intervention was performed using a modified iridocyclectomy technique. Sclerocorneal dissection of the involved quadrant was performed. After a lensectomy, an additional deep lamellar dissection of the peripheral cornea was undertaken prior to iris cyst removal and pupil reconstruction. This modified two-layered iridocyclectomy technique permits an elegant access to the iris lesion and allows the construction of a two-layered watertight wound, reducing the risk of hypotony and wound ectasia. We believe it also allows a better control of astigmatism and is a safe procedure in the pediatric population, particularly during the amblyogenic period.
The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...
Crabbe, M J C
2009-12-01
Climate change will have serious effects on the planet and on its ecosystems. Currently, mitigation efforts are proving ineffectual in reducing anthropogenic CO2 emissions. Coral reefs are the most sensitive ecosystems on the planet to climate change, and here we review modelling a number of geoengineering options, and their potential influence on coral reefs. There are two categories of geoengineering, shortwave solar radiation management and longwave carbon dioxide removal. The first set of techniques only reduce some, but not all, effects of climate change, while possibly creating other problems. They also do not affect CO2 levels and therefore fail to address the wider effects of rising CO2, including ocean acidification, important for coral reefs. Solar radiation is important to coral growth and survival, and solar radiation management is not in general appropriate for this ecosystem. Longwave carbon dioxide removal techniques address the root cause of climate change, rising CO2 concentrations, they have relatively low uncertainties and risks. They are worthy of further research and potential implementation, particularly carbon capture and storage, biochar, and afforestation methods, alongside increased mitigation of atmospheric CO2 concentrations.
Process Design Manual: Wastewater Treatment Facilities for Sewered Small Communities.
ERIC Educational Resources Information Center
Leffel, R. E.; And Others
This manual attempts to describe new treatment methods, and discuss the application of new techniques for more effectively removing a broad spectrum of contaminants from wastewater. Topics covered include: fundamental design considerations, flow equalization, headworks components, clarification of raw wastewater, activated sludge, package plants,…
ARSENIC REMOVAL USING SOL-GEL SYNTHESIZED TITANIUM DIOXIDE NANOPARTICLES
In this study, the effectiveness of TiO2 nanoparticles in arsenic adsorption was examined. TiO2 particles (LS) were synthesized via sol-gel techniques and characterized for their crystallinity, surface area and pore volume. Batch adsorption studies were perf...
Carroll, Patrick D.; Widness, John A.
2012-01-01
The development of anemia after birth in very premature, critically ill newborn infants is a universal well-described phenomenon. Although preventing anemia in this population, along with efforts to establish optimal red blood cell (RBC) transfusion and pharmacologic therapy continue to be actively investigated, the present review focuses exclusively on nonpharmacological approaches to the prevention and treatment of neonatal anemia. We begin with an overview of topics relevant to nonpharmacological techniques. These topics include neonatal and fetoplacental hemoglobin levels and blood volumes, clinical and laboratory practices applied in critically ill neonates, and current RBC transfusion practice guidelines. This is followed by a discussion of the most effective and promising nonpharmacological blood conservation strategies and techniques. Fortunately, many of these techniques are feasible in most neonatal intensive care units. When applied together, these techniques are more effective than existing pharmacotherapies in significantly decreasing neonatal RBC transfusions. They include increasing hemoglobin endowment and circulating blood volume at birth; removing less blood for laboratory testing; and optimizing nutrition. PMID:22818543
Ma, Jie; Yang, Mingxuan; Yu, Fei; Chen, Junhong
2015-04-15
We report a facile solid method to synthesize efficient carbon-based Fenton-like catalyst (CNTs/FeS) using as-prepared carbon nanotubes (APCNTs), which makes full use of the iron nanoparticles in APCNTs without needless purification. Furthermore, the CNTs/FeS was characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD), thermogravimetric (TG) and other analysis techniques, and then the CNTs/FeS was used as a Fenton-like catalyst for removing ciprofloxacin from aqueous solution. Response Surface Methodology (RSM) was applied to find the effect of the reaction parameter and the optimum operating condition. Results shows the catalytic reaction had better suitability than previous studies in a wide range of pH values (pH 3-8) and the Fenton-like catalyst CNTs/FeS exhibits good catalytic activity for removing of antibiotic, which be attributed to the synergistic effect of adsorption-advanced oxidation and significantly improves efficiency of advanced oxidation. More importantly, the CNTs/FeS catalyst exhibit good regeneration performance and retains a high catalytic capacity (>75%) even after four reaction cycles. The catalytic mechanism were also studied further, the removal mechanism of ciprofloxacin by a CNTs/FeS heterogeneous Fenton-like process primarily involves three removal pathways occurring simultaneously: (a) adsorption removal by CNTs, (b) Fenton-like degradation catalyzed by FeS, (c) catalytic degradation by CNTs catalyst. And these actions also have synergistic effects for ciprofloxacin removal. Copyright © 2014 Elsevier Inc. All rights reserved.
Evaluating of arsenic(V) removal from water by weak-base anion exchange adsorbents.
Awual, M Rabiul; Hossain, M Amran; Shenashen, M A; Yaita, Tsuyoshi; Suzuki, Shinichi; Jyo, Akinori
2013-01-01
Arsenic contamination of groundwater has been called the largest mass poisoning calamity in human history and creates severe health problems. The effective adsorbents are imperative in response to the widespread removal of toxic arsenic exposure through drinking water. Evaluation of arsenic(V) removal from water by weak-base anion exchange adsorbents was studied in this paper, aiming at the determination of the effects of pH, competing anions, and feed flow rates to improvement on remediation. Two types of weak-base adsorbents were used to evaluate arsenic(V) removal efficiency both in batch and column approaches. Anion selectivity was determined by both adsorbents in batch method as equilibrium As(V) adsorption capacities. Column studies were performed in fixed-bed experiments using both adsorbent packed columns, and kinetic performance was dependent on the feed flow rate and competing anions. The weak-base adsorbents clarified that these are selective to arsenic(V) over competition of chloride, nitrate, and sulfate anions. The solution pH played an important role in arsenic(V) removal, and a higher pH can cause lower adsorption capacities. A low concentration level of arsenic(V) was also removed by these adsorbents even at a high flow rate of 250-350 h(-1). Adsorbed arsenic(V) was quantitatively eluted with 1 M HCl acid and regenerated into hydrochloride form simultaneously for the next adsorption operation after rinsing with water. The weak-base anion exchange adsorbents are to be an effective means to remove arsenic(V) from drinking water. The fast adsorption rate and the excellent adsorption capacity in the neutral pH range will render this removal technique attractive in practical use in chemical industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finch, T.E.; Fidler, E.L.
1981-02-01
This report defines the state of the art (circa 1978) in removing thin coal seams associated with vastly thicker seams found in the surface coal mines of the western United States. New techniques are evaluated and an innovative method and machine is proposed. Western states resource recovery regulations are addressed and representative mining operations are examined. Thin seam recovery is investigated through its effect on (1) overburden removal, (2) conventional seam extraction methods, and (3) innovative techniques. Equations and graphs are used to accommodate the variable stratigraphic positions in the mining sequence on which thin seams occur. Industrial concern andmore » agency regulations provided the impetus for this study of total resource recovery. The results are a compendium of thin seam removal methods and costs. The work explains how the mining industry recovers thin coal seams in western surface mines where extremely thick seams naturally hold the most attention. It explains what new developments imply and where to look for new improvements and their probable adaptability.« less
Effect of a new pre-brushing rinse on dental plaque removal.
Vouros, J; Sakellari, D; Konstantinidis, A
1994-11-01
Non-prescription prebrushing rinses to facilitate dental plaque removal have been advertised in recent years. The purpose of the present study was to determine the plaque removal effectiveness of Plax (Colgate) prebrushing rinse by comparing it to a placebo solution. 19 dental students volunteered for this double blind study which consisted of 2 experimental periods. The following procedure was followed: 3 weeks after scaling and polishing, the participants abstained from oral hygiene for 3 days to allow dental plaque to accumulate. After plaque disclosing, the 4 mandibular incisors were photographed using a strictly defined technique, as described by Quirynen et al. Then the volunteers mouthrinsed for 30 s with 15 ml of a solution provided to them. Neither the volunteers nor the examiners knew which solution (test or control) was used. After mouthrinsing, the participants were allowed to brush their teeth and the remaining plaque was photographed again. During the 2nd experimental period, the same procedure was followed, and the 2nd solution was used for mouthrinsing. The effectiveness of the solutions was evaluated by comparing the proportion of dental plaque removed during the 2 experimental periods. The area of dental plaque was measured by an electronic high-precision device (planimeter). The proportion of plaque removed after rinsing with Plax was 0.40 +/- 0.23 and after rising with placebo 0.42 +/- 0.24, of the tooth surface (p = 0.962). Analysis of data by means of paired t-test between the 2 experimental periods revealed no beneficial effect regarding plaque removal when Plax was used.
NASA Astrophysics Data System (ADS)
Mant, Jenny; Janes, Victoria; Terrell, Robert; Allen, Deonie; Arthur, Scott; Yeakley, Alan; Morse, Jennifer; Holman, Ian
2015-04-01
Outfalls represent points of discharge to a river and often contain pollutants from urban runoff, such as heavy metals. Additionally, erosion around the outfall site results in increased sediment generation and the release of associated pollutants. Water quality impacts from heavy metals pose risks to the river ecosystem (e.g. toxicity to aquatic habitats). Restoration techniques including establishment of swales, and the re-vegetation and reinforcement of channel banks aim to decrease outfall flow velocities resulting in deposition of pollutants and removal through plant uptake. Within this study the benefits of river restoration techniques for the removal of contaminants associated with outfalls have been quantified within Johnson Creek, Portland, USA as part of the EPSRC funded Blue-Green Cities project. The project aims to develop new strategies for protecting hydrological and ecological values of urban landscapes. A range of outfalls have been selected which span restored and un-restored channel reaches, a variety of upstream land-uses, and both direct and set-back outfalls. River Habitat Surveys were conducted at each of the sites to assess the level of channel modification within the reach. Sediment samples were taken at the outfall location, upstream, and downstream of outfalls for analysis of metals including Nickel, Lead, Zinc, Copper, Iron and Magnesium. These were used to assess the impact of the level of modification at individual sites, and to compare the influence of direct and set-back outfalls. Concentrations of all metals in the sediments found at outfalls generally increased with the level of modification at the site. Sediment in restored sites had lower metal concentrations both at the outfall and downstream compared to unrestored sites, indicating the benefit of these techniques to facilitate the effective removal of pollutants by trapping of sediment and uptake of contaminants by vegetation. However, the impact of restoration measures varied between metal types. Restored sites also showed lower variability in metal concentrations than un-restored sites, which is linked to greater bank stability and hence lower bank erosion rates within restored sites as eroding banks were noted to be a source of metal contaminants. The success of pollutant removal by set-back outfalls was varied due to additional factors including the distance between the set-back outfall and the main channel, vegetation type, density and age. The study highlights the ability of restoration techniques to reduce metal contaminant concentrations at outfalls, and provides an indication of the potential benefits from wider application of similar techniques.
Nonoperative options for management of residual stones after cholecystostomy in high-risk patients
NASA Astrophysics Data System (ADS)
Reed, David M.; Daye, S. S.; Lincer, R. M.
1993-05-01
Cholecystostomy is frequently performed to obtain control of sepsis in high risk patients with acute cholecystitis. Retained stones in the gallbladder may cause future clinical problems. We present two patients with cholecystostomy tubes managed non-operatively. A review of other reported methods for stone extraction or destruction is also presented. Knowledge of safe and effective techniques for removal of these stones, using minimally invasive techniques is useful to the general surgeon.
The purification process on scintillator material (SrI{sub 2}: Eu) by zone-refinement technique
DOE Office of Scientific and Technical Information (OSTI.GOV)
Arumugam, Raja; Daniel, D. Joseph; Ramasamy, P., E-mail: ramasamyp@ssn.edu.in
The thermal properties of Europium doped strontium iodide was analyzed through Thermogravimetric (TG) and differential thermal analyses (DTA). The melting point of europium doped strontium iodide is around 531°C. The hydrated and oxyhalide impurities were found before melting temperature. In order to remove these impurities we have done purification process by Zone-refinement technique. The effective output of purification of zone refining was also observed through the segregation of impurities.
[Technique for removing donor sclera by eyeball extrusion].
González Del Valle, F; Álvarez Portela, M; Lara Medina, J; Celis Sánchez, J; Barrajón Rodríguez, A
2012-09-01
To describe a surgery technique for removing donor sclera tissue after corneo-scleral button excision. The extrusion technique is easy to perform. It allows the complete scleral extraction its total clean up to be performed, as well as making easier to isolate the retina and uveal tissue. This technique could have an important role in the anatomical and morphological study of ocular structures. Copyright © 2011 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.
A review on pesticide removal through different processes.
Marican, Adolfo; Durán-Lara, Esteban F
2018-01-01
The main organic pollutants worldwide are pesticides, persistent chemicals that are of concern owing to their prevalence in various ecosystems. In nature, pesticide remainders are subjected to the chemical, physical, and biochemical degradation process, but because of its elevated stability and some cases water solubility, the pesticide residues persist in the ecosystem. The removal of pesticides has been performed through several techniques classified under biological, chemical, physical, and physicochemical process of remediation from different types of matrices, such as water and soil. This review provides a description of older and newer techniques and materials developed to remove specific pesticides according to previous classification, which range from bioremediation with microorganisms, clay, activated carbon, and polymer materials to chemical treatment based on oxidation processes. Some types of pesticides that have been removed successfully to large and small scale include, organophosphorus, carbamates, organochlorines, chlorophenols, and synthetic pyrethroids, among others. The most important characteristics, advantages, and disadvantages of techniques and materials for removing pesticides are described in this work.
A NOVEL TECHNIQUE APPLYING SPECTRAL ESTIMATION TO JOHNSON NOISE THERMOMETRY
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ezell, N Dianne Bull; Britton Jr, Charles L; Roberts, Michael
Johnson noise thermometry (JNT) is one of many important measurements used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift free temperature measurements. The two techniques developed by Oak Ridge National Laboratory (ORNL) to remove transient and periodic EMI are briefly discussed in this document. Spectral estimation is a key component in the signal processing algorithm utilized for EMI removal and temperature calculation. Applying these techniques requires the simple addition of the electronics and signal processing tomore » existing resistive thermometers.« less
Vitreoretinal surgery in advanced coats disease.
Ozdamar, Yasemin; Berker, Nilufer; Batman, Cosar; Zilelioglu, Orhan
2009-01-01
To report the outcomes of vitreoretinal surgery for a patient with total retinal detachment and a subretinal nodule associated with Coats disease (CD). A 20-year-old woman stage 3B CD underwent vitreoretinal surgery with triamcinolone acetonide-assisted pars plana vitrectomy, limited retinotomy, removal of the subretinal nodule and membrane, endolaser photocoagulation, and silicone oil tamponade. The surgical outcomes were observed. Retinal attachment was achieved after vitreoretinal surgery, removal of the subretinal membrane, and endoresection of the subretinal fibrous nodule. No intraoperative or postoperative complications occurred due to the surgical technique. The retina remained attached during the postoperative follow-up period of 6 months. Vitreoretinal surgery is an effective surgical technique that provides successful reattachment of the retina and enables endoresection of the subretinal fibrous nodule in eyes with advanced CD. It also prevents the devastating intraocular complications leading to enucleation.
Active cleaning technique for removing contamination from optical surfaces in space
NASA Technical Reports Server (NTRS)
Shannon, R. L.; Gillette, R. B.; Cruz, G. A.
1973-01-01
An active cleaning technique for removing contaminants from optical surfaces in space was investigated with emphasis on the feasibility of using plasma exposure as a means of in-situ cleaning. The major work accomplished includes: (1) development of an in-situ reflectometer for use in conjunction with the contaminant film deposition/cleaning facility; (2) completion of Apollo Telescope Mount (ATM) filter treatment experiments to assess the effects of plasma exposure on the UV transmittance; (3) attempts to correlate the atomic oxygen flux with cleaning rate; (4) completion of in-situ butadien contamination/plasma cleaning/UV reflectance measurement experiments; (5) carbon cleaning experiments using various gases; (6) completion of silicone contamination/cleaning experiments; and (7) experiments conducted at low chamber pressures to determine cleaning rate distribution and contamination of surfaces adjacent to those being cleaned.
Kwak, Young-Seok; Cho, Dae-Chul; Kim, Young-Baeg
2012-01-01
Conventional laminectomy is the most popular technique for the complete removal of intradural spinal tumors. In particular, the central portion intramedullary tumor and large intradural extramedullary tumor often require a total laminectomy for the midline myelotomy, sufficient decompression, and adequate visualization. However, this technique has the disadvantages of a wide incision, extensive periosteal muscle dissection, and bony structural injury. Recently, split-spinous laminectomy and tubular retractor systems were found to decrease postoperative muscle injuries, skin incision size and discomfort. The combined technique of split-spinous laminectomy, using a quadrant tube retractor system allows for an excellent exposure of the tumor with minimal trauma of the surrounding tissue. We propose that this technique offers possible advantages over the traditional open tumor removal of the intradural spinal cord tumors, which covers one or two cervical levels and requires a total laminectomy. PMID:23133739
Critical assessment of chitosan as coagulant to remove cyanobacteria.
Lürling, Miquel; Noyma, Natalia Pessoa; de Magalhães, Leonardo; Miranda, Marcela; Mucci, Maíra; van Oosterhout, Frank; Huszar, Vera L M; Marinho, Marcelo Manzi
2017-06-01
Removal of cyanobacteria from the water column using a coagulant and a ballast compound is a promising technique to mitigate nuisance. As coagulant the organic, biodegradable polymer chitosan has been promoted. Results in this study show that elevated pH, as may be common during cyanobacterial blooms, as well as high alkalinity may hamper the coagulation of chitosan and thus impair its ability to effectively remove positively buoyant cyanobacteria from the water column. The underlying mechanism is likely a shielding of the protonated groups by anions. Inasmuch as there are many chitosan formulations, thorough testing of each chitosan prior to its application is essential. Results obtained in glass tubes were similar to those from standard jar tests demonstrating that glass tube tests can be used for testing effects of coagulants and ballasts in cyanobacteria removal whilst allowing far more replicates. There was no relation between zeta potential and precipitated cyanobacteria. Given the well-known antibacterial activity of chitosan and recent findings of anti-cyanobacterial effects, pre-application tests are needed to decipher if chitosan may cause cell leakage of cyanotoxins. Efficiency- and side-effect testing are crucial for water managers to determine if the selected approach can be used in tailor-made interventions to control cyanobacterial blooms and to mitigate eutrophication. Copyright © 2017 Elsevier B.V. All rights reserved.
Chys, Michael; Demeestere, Kristof; Ingabire, Ange Sabine; Dries, Jan; Van Langenhove, Herman; Van Hulle, Stijn W H
2017-07-01
Ozonation and three (biological) filtration techniques (trickling filtration (TF), slow sand filtration (SSF) and biological activated carbon (BAC) filtration) have been evaluated in different combinations as tertiary treatment for municipal wastewater effluent. The removal of 18 multi-class pharmaceuticals, as model trace organic contaminants (TrOCs), has been studied. (Biological) activated carbon filtration could reduce the amount of TrOCs significantly (>99%) but is cost-intensive for full-scale applications. Filtration techniques mainly depending on biodegradation mechanisms (TF and SSF) are found to be inefficient for TrOCs removal as a stand alone technique. Ozonation resulted in 90% removal of the total amount of quantified TrOCs, but a post-ozonation step is needed to cope with an increased unselective toxicity. SSF following ozonation showed to be the only technique able to reduce the unselective toxicity to the same level as before ozonation. In view of process control, innovative correlation models developed for the monitoring and control of TrOC removal during ozonation, are verified for their applicability during ozonation in combination with TF, SSF or BAC. Particularly for the poorly ozone reactive TrOCs, statistically significant models were obtained that correlate TrOC removal and reduction in UVA 254 as an online measured surrogate parameter.
Pervaporative stripping of acetone, butanol and ethanol to improve ABE fermentation.
Jitesh, K; Pangarkar, V G; Niranjan, K
2000-01-01
Acetone-butanol-ethanol fermentation by anaerobic bacterium C. acetobutylicum is a potential source for feedstock chemicals. The problem of product induced inhibition makes this fermentation economically infeasible. Pervaporation is studied as an effective separation technique to remove the toxic inhibitory products. Various membranes like Styrene Butadiene Rubber (SBR), Ethylene Propylene Diene Rubber (EPDM), plain Poly Dimethyl Siloxane (PDMS) and silicalite filled PDMS were studied for the removal of acetone, butanol and ethanol, from binary aqueous mixtures and from a quaternary mixture. It was found that the overall performance of PDMS filled with 15% w/w of silicalite was the best for removal of butanol in binary mixture study. SBR performance was best for the quaternary mixture studied.
[Microcystin safety study during Cyanobacteria removal by pressure enhanced coagulation process].
Jiang, Xin-Yue; Luan, Qing; Cong, Hai-Bing; Xu, Si-Tao; Liu, Yu-Jiao; Zhu, Xue-Yuan
2014-11-01
Pressure enhanced coagulation and sedimentation technique is an effective way for blue algae treatment. It is not clear whether Cyanobacteria balloon rupture will cause Cyanobacteria cells rupture, resulting in high intracellular concentrations of microcystin LR leak into the water, affecting drinking water safety. Therefore, in this study experimental comparative study of pressure and pre-oxidation of water containing Cyanobacteria was carried out to examine the microcystin LR concentration changes and Cyanobacteria removal efficiency. The results showed that microcystin concentration increase was not significant by the pre-treatment with Cyanobacteria water pressure, while the pre-oxidation process caused a significant increase in the concentration of microcystin. After 0.5-0.8 MPa pressure coagulation and sedimentation, removal of Cyanobacteria basically was over 90%, up to 93.5%, while the removal rate by pre-oxidation was low and unstable. Effluent turbidity is also significantly better in the pre-pressure method than the pre-oxidation. The results indicated that pressure enhanced coagulation is a safe and reliable method for Cyanobacteria removal.
Defluoridation potential of jute fibers grafted with fatty acyl chain
NASA Astrophysics Data System (ADS)
Manna, Suvendu; Saha, Prosenjit; Roy, Debasis; Sen, Ramkrishna; Adhikari, Basudam
2015-11-01
Waterborne fluoride is usually removed from water by coagulation, adsorption, ion exchange, electro dialysis or reverse osmosis. These processes are often effective over narrow pH ranges, release ions considered hazardous to human health or produce large volumes of toxic sludge that are difficult to handle and dispose. Although plant matters have been shown to remove waterborne fluoride, they suffer from poor removal efficiency. Following from the insight that interaction between microbial carbohydrate biopolymers and anionic surfaces is often facilitated by lipids, an attempt has been made to enhance fluoride adsorption efficiency of jute by grafting the lignocellulosic fiber with fatty acyl chains found in vegetable oils. Fluoride removal efficiency of grafted jute was found to be comparable or higher than those of alternative defluoridation processes. Infrared and X-ray photoelectron spectroscopic evidence indicated that hydrogen bonding, protonation and C-F bonding were responsible for fluoride accumulation on grafted jute. Adsorption based on grafted jute fibers appears to be an economical, sustainable and eco-friendly alternative technique for removing waterborne fluoride.
Removal of press-through-packs impacted in the upper esophagus using an overtube.
Seo, Yeon-Seok; Park, Jong-Jae; Kim, Ji-Hoon; Kim, Jin-Yong; Yeon, Jong-Eun; Kim, Jae-Seon; Byun, Kwan-Soo; Bak, Young-Tae
2006-09-28
Foreign bodies in the upper esophagus should be removed as soon as possible to avoid serious complications. However, removals of foreign bodies in the upper esophagus are very difficult, especially if they have sharp edges, such as press-through-packs (PTPs). We experienced four cases of the impacted PTPs in the upper esophagus which was successfully extracted endoscopically with the overtube. Because two edges of PTPs were so firmly impacted in the esophageal wall in all cases, the PTPs were not movable in the upper esophagus. However, after insertion of the overtube, PTPs became movable and were successfully extracted and no serious complications occurred after extraction of PTPs. In one case, insertion of the overtube rapidly expanded the upper esophagus and PTP progressed to the gastric cavity and it could be extracted with the endoscopic protector hood. The endoscopic removal with the overtube was a simple, safe and effective technique for the removal of the impacted PTPs in upper esophagus.
Removal of press-through-packs impacted in the upper esophagus using an overtube
Seo, Yeon Seok; Park, Jong-Jae; Kim, Ji Hoon; Kim, Jin Yong; Yeon, Jong Eun; Kim, Jae Seon; Byun, Kwan Soo; Bak, Young-Tae
2006-01-01
Foreign bodies in the upper esophagus should be removed as soon as possible to avoid serious complications. However, removals of foreign bodies in the upper esophagus are very difficult, especially if they have sharp edges, such as press-through-packs (PTPs). We experienced four cases of the impacted PTPs in the upper esophagus which was successfully extracted endoscopically with the overtube. Because two edges of PTPs were so firmly impacted in the esophageal wall in all cases, the PTPs were not movable in the upper esophagus. However, after insertion of the overtube, PTPs became movable and were successfully extracted and no serious complications occurred after extraction of PTPs. In one case, insertion of the overtube rapidly expanded the upper esophagus and PTP progressed to the gastric cavity and it could be extracted with the endoscopic protector hood. The endoscopic removal with the overtube was a simple, safe and effective technique for the removal of the impacted PTPs in upper esophagus. PMID:17007065
New trends in removing heavy metals from wastewater.
Zhao, Meihua; Xu, Ying; Zhang, Chaosheng; Rong, Hongwei; Zeng, Guangming
2016-08-01
With the development of researches, the treatments of wastewater have reached a certain level. Whereas, heavy metals in wastewater cause special concern in recent times due to their recalcitrance and persistence in the environment. Therefore, it is important to get rid of the heavy metals in wastewater. The previous studies have provided many alternative processes in removing heavy metals from wastewater. This paper reviews the recent developments and various methods for the removal of heavy metals from wastewater. It also evaluates the advantages and limitations in application of these techniques. A particular focus is given to innovative removal processes including adsorption on abiological adsorbents, biosorption, and photocatalysis. Because these processes have leaded the new trends and attracted more and more researches in removing heavy metals from wastewater due to their high efficency, pluripotency and availability in a copious amount. In general, the applicability, characteristic of wastewater, cost-effectiveness, and plant simplicity are the key factors in selecting the most suitable method for the contaminated wastewater.
Removal of phosphate from aqueous solutions and sewage using natural and surface modified coir pith.
Krishnan, K Anoop; Haridas, Ajit
2008-04-01
Iron impregnated coir pith (CP-Fe-I) can be effectively used for the removal of phosphate from aqueous streams and sewage. Iron impregnation on natural coir pith was carried out by drop by drop addition method. The effect of various factors such as pH, initial concentration of phosphate, contact time and adsorbent dose on phosphate adsorption was studied by batch technique. The pH at 3.0 favored the maximum adsorption of phosphate from aqueous solutions. The effect of pH on phosphate adsorption was explained by pH(zpc), phosphate speciation in solution and affinity of anions towards the adsorbent sites. A comparative study of the adsorption of phosphate using CP-Fe-I and CP (coir pith) was made and results show that the former one is five to six times more effective than the latter. Kinetic studies revealed that the adsorption process followed a pseudo-second order kinetic model. Adsorption followed Langmuir isotherm model. Column studies were conducted to examine the utility of the investigated adsorbent for the removal of phosphate from continuously flowing aqueous solutions.
Effect of PAC dosage in a pilot-scale PAC-MBR treating micro-polluted surface water.
Hu, Jingyi; Shang, Ran; Deng, Huiping; Heijman, Sebastiaan G J; Rietveld, Luuk C
2014-02-01
To address the water scarcity issue and advance the traditional drinking water treatment technique, a powdered activated carbon-amended membrane bioreactor (PAC-MBR) is proposed for micro-polluted surface water treatment. A pilot-scale study was carried out by initially dosing different amounts of PAC into the MBR. Comparative results showed that 2g/L performed the best among 0, 1, 2 and 3g/L PAC-MBR regarding organic matter and ammonia removal as well as membrane flux sustainability. 1g/L PAC-MBR exhibited a marginal improvement in pollutant removal compared to the non-PAC system. The accumulation of organic matter in the bulk mixture of 3g/L PAC-MBR led to poorer organic removal and severer membrane fouling. Molecular weight distribution of the bulk liquid in 2g/L PAC-MBR revealed the synergistic effects of PAC adsorption/biodegradation and membrane rejection on organic matter removal. Additionally, a lower amount of soluble extracellular polymer substances in the bulk can be secured in 21 days operation. Copyright © 2013 Elsevier Ltd. All rights reserved.
Gluskin, Alan H; Ruddle, Clifford J; Zinman, Edwin J
2005-09-01
The use of ultrasonic energy is a highly efficient method of removing obstructions and cements within the root canal space when re-treatment or rehabilitation of that ultrasonic energy dislodges and removes cemented objects from the bonded interface of the canal wall. When using this method, there is less potential for structural loss or root damage and significantly less operator stress than when using other methods. There is little evidence in published research of the considerable heat transfer that occurs during use of ultrasonic devices to remove posts, pastes and separated instruments in teeth. The authors present three cases of patients who experienced serious burn injuries during application of ultrasonic energy for restorative dentistry. The authors also offer techniques and strategies for safe and effective use of ultrasonic devices. On the basis of the best available evidence, the authors recommend strategies to provide safe and effective therapy while using ultrasonic devices in intraradicular obstruction removal. The intent of the suggested protocols is to provide advanced and sophisticated therapies in a safe and regulated manner with patient safety as an overriding priority.
Durán, A; Monteagudo, J M; Sanmartín, I; Gómez, P
2013-03-01
The mineralization of industrial wastewater coming from food industry using an emerging homogeneous sonophotolytic oxidation process was evaluated as an alternative to or a rapid pretreatment step for conventional anaerobic digestion with the aim of considerably reducing the total treatment time. At the selected operation conditions ([H(2)O(2)]=11,750ppm, pH=8, amplitude=50%, pulse length (cycles)=1), 60% of TOC is removed after 60min and 98% after 180min when treating an industrial effluent with 2114ppm of total organic carbon (TOC). This process removed completely the toxicity generated during storing or due to intermediate compounds. An important synergistic effect between sonolysis and photolysis (H(2)O(2)/UV) was observed. Thus the sonophotolysis (ultrasound/H(2)O(2)/UV) technique significantly increases TOC removal when compared with each individual process. Finally, a preliminary economical analysis confirms that the sono-photolysis with H(2)O(2) and pretreated water is a profitable system when compared with the same process without using ultrasound waves and with no pretreatment. Copyright © 2012 Elsevier B.V. All rights reserved.
Intraluminal pneumatic lithotripsy for the removal of encrusted urinary catheters.
Canby-Hagino, E D; Caballero, R D; Harmon, W J
1999-12-01
Urologists frequently treat patients requiring long-term urinary drainage with a percutaneous nephrostomy tube or ureteral stent. When such tubes are neglected and become encrusted, removal challenges even experienced urologists. We describe a new, minimally invasive technique for safely and rapidly removing encrusted, occluded tubes using the Swiss Lithoclast pneumatic lithotriptor. Patients presenting with an encrusted urinary catheter were evaluated by excretory urography for renal function and obstruction. Gentle manual extraction of the tube was attempted, followed by traditional extracorporeal shock wave lithotripsy and/or ureteroscopy. When the tube was not extracted, patients were then treated with intraluminal insertion of a pneumatic lithotripsy probe. One patient presented with an encrusted, occluded nephrostomy tube and 2 had an encrusted, occluded, indwelling ureteral stent. None was removed by manual traction. Intraluminal encrustations prevented the pigtail portions of these tubes from uncoiling and removal. In each case a pneumatic lithotripsy probe was inserted into the lumen of the catheter and advanced in a jackhammer-like fashion. This technique resulted in disruption of the intraluminal encrustations and straightening of the tubes so that they were removed in an atraumatic manner. Intraluminal pneumatic lithotripsy is a safe, easy and rapid technique for removing encrusted urinary catheters. It is unique in that the pneumatic lithotripsy probe functions in an aqueous and nonaqueous environment, and dislodges intraluminal calcifications. We recommend its use as first line treatment for removing encrusted urinary catheters.
[Osteosynthesis by tension band wiring of displaced fractures of the olecranon].
Doursounian, L; Prevot, O; Touzard, R C
1994-01-01
Fifty-two displaced olecranon fractures in adults were treated over a 5-year period. Minimum follow-up was 6 months. Forty-eight fractures were operated and 38 were treated by tension band wiring technique. This technique, applied for all types of fractures, gave good functional results in 33 cases (87%) and fair functional results in 5 cases. Complications include 1 pseudarthrosis, 2 loss of reduction, 2 transient tourniquet palsy and 13 skin problems due to wire protrusion. Tension band wiring is a simple safe and effective technique for displaced olecranon fractures but often requires K-wire removal.
Surgical treatment of axillary hyperhidrosis by suction-curettage of sweat glands*
de Rezende, Rebeca Maffra; Luz, Flávio Barbosa
2014-01-01
Suction curettage is a dermatologic surgery technique for the treatment of axillary hyperhidrosis, which is becoming more popular. Objective: The purpose of this study is to describe the current technique of removal of axillary sweat glands, and evaluate its efficacy and safety. Conclusion: Suction-curettage of sweat glands is a minimally invasive surgical technique that is easy to perform, safe, has high rates of success and relatively few side-effects. It is generally well tolerated by patients and requires shorter time away from daily activities, when compared with other surgical modalities. PMID:25387499
Laparoscopic-assisted extracorporeal ovarian cystectomy: a new technique.
Ikuma, Kenichino; Amin, Magdy; Yukio, Yamada; Hisato, Okuo; Yoshihiro, Ito; Shintaro, Ueda; Masako, Tanaka; Yasuki, Koyasu
2004-01-01
An increasing number of adnexal masses are currently managed laparoscopically, which has hampered progress regarding the different techniques of laparoscopic surgery. In this chapter, a modified application of surgical instrument was described in laparoscopic ovarian cystectomy-we named this device, Lap-Disc Mini. This new instrument has three rings, an inner flexible ring fixed to a middle ring by a rubber corset, and an additional dynamic outer ring that has a rubbery-like iris opening, which allows the application of different-sized trocars and extracorporeal ovarian cystectomy. This technique has proved to be effective and safe, especially in removing large ovarian cyst.
Extending the use of ultraviolet light for fruit quality sorting in citrus packinghouses
USDA-ARS?s Scientific Manuscript database
Illumination with ultraviolet light (UV) is commonly used in citrus packinghouses as a means to aid in the identification and removal of decayed oranges from the packline. This technique is effective because areas of decay strongly fluoresce under UV illumination. It was observed that oranges often ...
A pilot-scale field experiment was conducted to compare the remediation effectiveness of an enhanced-solubilization technique to that of water flushing for removal of multicomponent nonaqueous-phase organic liquid (NAPL) contaminants form a phreatic aquifer. This innovative remed...
NASA Technical Reports Server (NTRS)
Rutledge, Sharon K.; Banks, Bruce A.; Cales, Michael
1994-01-01
Current techniques for removal of varnish (lacquer) and other organic protective coatings from paintings involve contact with the surface. This contact can remove pigment, or alter the shape and location of paint on the canvas surface. A thermal energy atomic oxygen plasma, developed to simulate the space environment in low Earth orbit, easily removes these organic materials. Uniform removal of organic protective coatings from the surfaces of paintings is accomplished through chemical reaction. Atomic oxygen will not react with oxides so that most paint pigments will not be affected by the reaction. For paintings containing organic pigments, the exposure can be carefully timed so that the removal stops just short of the pigment. Color samples of Alizarin Crimson, Sap Green, and Zinc White coated with Damar lacquer were exposed to atomic oxygen. The lacquer was easily removed from all of the samples. Additionally, no noticeable change in appearance was observed after the lacquer was reapplied. The same observations were made on a painted canvas test sample obtained from the Cleveland Museum of Art. Scanning electron microscope photographs showed a slight microscopic texturing of the vehicle after exposure. However, there was no removal or disturbance of the paint pigment on the surface. It appears that noncontact cleaning using atomic oxygen may provide a viable alternative to other cleaning techniques. It is especially attractive in cases where the organic protective surface cannot be acceptably or safely removed by conventional techniques.
Studies of EUV contamination mitigation
NASA Astrophysics Data System (ADS)
Graham, Samual, Jr.; Malinowski, Michael E.; Steinhaus, Chip; Grunow, Philip A.; Klebanoff, Leonard E.
2002-07-01
Carbon contamination removal was investigated using remote RF-O2, RF-H2, and atomic hydrogen experiments. Samples consisted of silicon wafers coated with 100 Angstrom sputtered carbon, as well as bare Si-capped Mo/Si optics. Samples were exposed to atomic hydrogen or RF plasma discharges at 100 W, 200 W, and 300 W. Carbon removal rate, optic oxidation rate, at-wavelength (13.4 nm) peak reflectance, and optic surface roughness were characterized. Data show that RF- O2 removes carbon at a rate approximately 6 times faster RF- H2 for a given discharge power. However, both cleaning techniques induce Mo/Si optic degradation through the loss of reflectivity associated with surface oxide growth for RF-O2 and an unknown mechanism with hydrogen cleaning. Atomic hydrogen cleaning shows carbon removal rates sufficient for use as an in-situ cleaning strategy for EUVoptics with less risk of optic degradation from overexposures than RF-discharge cleaning. While hydrogen cleaning (RF and atomic) of EUV optics has proven effective in carbon removal, attempts to dissociate hydrogen in co-exposures with EUV radiation have resulted in no detectable removal of carbon contamination.
Li, Jie; Chen, Changlun; Zhang, Rui; Wang, Xiangke
2015-06-01
Nanoscale zero-valent iron particles supported on reduced graphene oxides (NZVI/rGOs) from spent graphene oxide (GO)-bound iron ions were developed by using a hydrogen/argon plasma reduction method to improve the reactivity and stability of NZVI. The NZVI/rGOs exhibited excellent water treatment performance with excellent removal capacities of 187.16 and 396.37 mg g(-1) for chromium and lead, respectively. Moreover, the NZVI/rGOs could be regenerated by plasma treatment and maintained high removal ability after four cycles. X-ray photoelectron spectroscopy analysis results implied that the removal mechanisms could be attributed to adsorption/precipitation, reduction, or both. Such multiple removal mechanisms by the NZVI/rGOs were attributed to the reduction ability of the NZVI particles and the role of dispersing and stabilizing abilities of the rGOs. The results indicated that the NZVI/rGOs prepared by a hydrogen/argon plasma reduction method might be an effective composite for heavy-metal-ion removal. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Liu, Zhen-Shu; Li, Wen-Kai; Hung, Ming-Jui
2014-09-01
Incineration flue gas contains polycyclic aromatic hydrocarbons (PAHs) and sulfur dioxide (SO2). The effects of SO2 concentration (0, 350, 750, and 1000 ppm), reaction temperature (160, 200, and 280 degrees C), and the type of activated carbon fibers (ACFs) on the removal of SO2 and PAHs by ACFs were examined in this study. A fluidized bed incinerator was used to simulate practical incineration flue gas. It was found that the presence of SO2 in the incineration flue gas could drastically decrease removal of PAHs because of competitive adsorption. The effect of rise in the reaction temperature from 160 to 280 degrees C on removal of PAHs was greater than that on SO2 removal at an SO2 concentration of 750 ppm. Among the three ACFs studied, ACF-B, with the highest microporous volume, highest O content, and the tightest structure, was the best adsorbent for removing SO2 and PAHs when these gases coexisted in the incineration flue gas. Implications: Simultaneous adsorption of sulfur dioxide (SO2) and polycyclic aromatic hydrocarbons (PAHs) emitted from incineration flue gas onto activated carbon fibers (ACFs) meant to devise a new technique showed that the presence of SO2 in the incineration flue gas leads to a drastic decrease in removal of PAHs because of competitive adsorption. Reaction temperature had a greater influence on PAHs removal than on SO2 removal. ACF-B, with the highest microporous volume, highest O content, and tightest structure among the three studied ACFs, was found to be the best adsorbent for removing SO2 and PAHs.
Effect of clinic related factors on continuation rates of IUDs.
Reading, A E; Goldstuck, N D
1982-01-01
This paper concerns factors relating to the clinic and the way in which the insertion of IUDs is managed from a psychological and technical standpoint. 3 aspects of clinical service are examined: 1) the influence of the psychological state at time of insertion, 2) individual differences in relation to side effects amongst users and the way in which those are influenced by managment techniques, and 3) technical aspects of the insertion of the device. Insertion pain and discomfort may influence subsequent tolerance of the IUD in 3 ways: 1) patient compliance may be enhanced by trouble-free insertion, 2) an unpleasant experience may influence attitudes towards the IUD, and 3) the experience of pain at insertion may reduce subsequent tolerance of discomfort. IUDs increase the amount of menstrual flow which, along with pain, constitute frequent requests for removal. Removal rates for pain and bleeding vary from 0-16.8/100 users. Removal rates for bleeding are also influenced by cultural attitudes. Insertion techniques influence acceptability of IUDs. Also, the incidence of expulsion, pregnancy, and removal declines with increasing age and parity. Discontinuation rates after 24 months were 91% for women below 2nd parity and only 37% for women of 6 or more parity. In the youngest age group the discontinuation rate was 76% compared with 35% in the oldest age group. The timing of IUD insertion and positioning of the IUD influence continuation rates. An implication of these concerns is that IUD insertion procedures may have to become more complex to achieve compatibility between IUD-uterine configurations.
Comparison of vocal outcomes after angiolytic laser surgery and microflap surgery for vocal polyps.
Mizuta, Masanobu; Hiwatashi, Nao; Kobayashi, Toshiki; Kaneko, Mami; Tateya, Ichiro; Hirano, Shigeru
2015-12-01
The microflap technique is a standard procedure for the treatment of vocal fold polyps. Angiolytic laser surgery carried out under topical anesthesia is an alternative method for vocal polyp removal. However, it is not clear whether angiolytic laser surgery has the same effects on vocal outcomes as the microflap technique because of a lack of studies comparing both procedures. In the current study, vocal outcomes after both procedures were compared to clarify the effects of angiolytic laser surgery for vocal polyp removal. Vocal outcomes were reviewed for patients who underwent angiolytic laser surgery (n=20, laser group) or microflap surgery (n=34, microflap group) for vocal polyp removal. The data analyzed included patient and lesion characteristics, number of surgeries required for complete resolution, and aerodynamic and acoustic examinations before and after surgery. In the laser surgery group, complete resolution of the lesion was achieved with a single procedure in 17 cases (85%) and with two procedures in 3 cases (15%). Postoperative aerodynamic and acoustic parameters demonstrated significant improvement compared to preoperative parameters in both the laser surgery group and the microflap surgery group. There were no significant differences in any postoperative aerodynamic and acoustic parameters between the two groups. The current retrospective study demonstrated that angiolytic laser surgery achieved complete resolution of vocal polyps within two procedures. Postoperative effects on aerodynamic and acoustic functions were similar to those after microflap surgery. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Using Fenton Oxidation to Simultaneously Remove Different Estrogens from Cow Manure
Sun, Minxia; Xu, Defu; Ji, Yuefei; Liu, Juan; Ling, Wanting; Li, Shunyao; Chen, Mindong
2016-01-01
The presence of estrogens in livestock excrement has raised concerns about their potential negative influence on animals and the overall food cycle. This is the first investigation to simultaneously remove estrogens, including estriol (E3), bisphenol A (BPA), diethylstilbestrol (DES), estradiol (E2), and ethinyl estradiol (EE2), from cow manure using a Fenton oxidation technique. Based on the residual concentrations and removal efficiency of estrogens, the Fenton oxidation reaction conditions were optimized as follows: a H2O2 dosage of 2.56 mmol/g, a Fe(II) to H2O2 molar ratio of 0.125 M/M, a solid to water mass ratio of 2 g/mL, an initial pH of 3, and a reaction time of 24 h. Under these conditions, the simultaneous removal efficiencies of E3, BPA, DES, E2, and EE2, with initial concentrations in cow manure of 97.40, 96.54, 100.22, 95.01, and 72.49 mg/kg, were 84.9%, 99.5%, 99.1%, 97.8%, and 84.5%, respectively. We clarified the possible Fenton oxidation reaction mechanisms that governed the degradation of estrogens. We concluded that Fenton oxidation technique could be effective for efficient removal of estrogens in livestock excrement. Results are of great importance for cow manure reuse in agricultural management, and can be used to reduce the threat of environmental estrogens to human health and ecological safety. PMID:27649223
Ntovas, Panagiotis; Loubrinis, Nikolaos; Maniatakos, Panagiotis; Rahiotis, Christos
2018-01-01
Objectives: The objective of this study was to assess the effect of the operator's degree of clinical experience on the residual caries diagnosis through visual inspection and tactile sensation. Materials and Methods: The participants were asked about the years of their clinical practice, any further training concerning cariology, their familiarity with the minimal invasive philosophy, and the techniques that they use to remove dental caries and detect when to stop the removal of carious tissues. In addition, an in vitro diagnostic test was conducted. Carious teeth were excavated to a level selected in random. Teeth were examined by each participant individually. Initial examination was performed by visual inspection. Subsequently, a dental explorer was used concerning the potential need for further removal of dental tissues. A sample of 380 dentists and dental school students were selected for the purposes of this study. Results: Dental students presented statistically significant better sensitivity, than dentists from both age groups, during both visual inspection and tactile sensation of residual caries. Participants' ability to diagnose residual caries during cavity preparation was independent of their years of experience. Conclusions: During the removal of carious lesions, with the goal of limiting the sacrifice of healthy structures and the leftover of residual caries, clinicians should combine a selective removal technique and the attentive visual inspection, with at least one further diagnostic method, aside from the dental explorer. Tactile examination of residual caries solely with the dental explorer must be used with attention. PMID:29899636
NASA Astrophysics Data System (ADS)
Li, Xiaofan; Shi, Shaoyuan; Cao, Hongbin; Li, Yuping; Xu, Dongyao
2018-06-01
Ion exchange process is an alternative technique for removal of heavy metal ions from industrial wastewater. The main aim of this paper is to evaluate the performance of different ion exchange resins in removing Cr(VI) from wastewater. The effects of resin types and dosage, initial pH were examined systemically. The results showed that the performance of different resins had obvious difference for the removal of the Cr(VI) ions, in which the type of functional groups of the resin was the main factor. The SEM images indicated that the micro-morphology of resins before and after adsorption of the Cr(VI) presented a little difference. The EDS analysis showed that the adsorbed Cr(VI) was uniformly distributed at the surface of the resins with formation of oxygen-containing groups. The adsorption isotherms and kinetics of Cr(VI) by the different resins are also discussed.
Implementation of ferric hydroxide-based media for removal of toxic metalloids
NASA Astrophysics Data System (ADS)
Szlachta, Małgorzata; Wójtowicz, Patryk
2017-11-01
Effective removal of inorganic arsenic species is possible by application of the sorption technique with the use of iron-based sorbents. This study investigates the removal of arsenic(III) and arsenic(V) from an aqueous solution by application of a granular ferric hydroxide-based sorbent. The performance of tested media was evaluated based on the batch and fixed-bed adsorption studies. The efficiency of the process was determined with various treatment times, adsorbent doses, initial concentrations of arsenic and various solution temperatures. The obtained adsorption data were fitted with pseudo-first and second-order kinetic models and Langmuir and Freundlich isotherm equations. It was observed that the overall arsenite removal was lower when compared to the arsenate, and all tested operating parameters influenced the process efficiency. The experiments under dynamic conditions showed high treatment capacity and stability of tested adsorbent over a long period of time.
Removal of 10-nm contaminant particles from Si wafers using CO2 bullet particles.
Kim, Inho; Hwang, Kwangseok; Lee, Jinwon
2012-04-11
Removal of nanometer-sized contaminant particles (CPs) from substrates is essential in successful fabrication of nanoscale devices. The particle beam technique that uses nanometer-sized bullet particles (BPs) moving at supersonic velocity was improved by operating it at room temperature to achieve higher velocity and size uniformity of BPs and was successfully used to remove CPs as small as 10 nm. CO2 BPs were generated by gas-phase nucleation and growth in a supersonic nozzle; appropriate size and velocity of the BPs were obtained by optimizing the nozzle contours and CO2/He mixture fraction. Cleaning efficiency greater than 95% was attained. BP velocity was the most important parameter affecting removal of CPs in the 10-nm size range. Compared to cryogenic Ar or N2 particles, CO2 BPs were more uniform in size and had higher velocity and, therefore, cleaned CPs more effectively.
Advances in Dust Detection and Removal for Tokamaks
NASA Astrophysics Data System (ADS)
Campos, A.; Skinner, C. H.; Roquemore, A. L.; Leisure, J. O. V.; Wagner, S.
2008-11-01
Dust diagnostics and removal techniques are vital for the safe operation of next step fusion devices such as ITER. An electrostatic dust detector[1] developed in the laboratory is being applied to NSTX. In the tokamak environment, large particles or fibres can fall on the grid potentially causing a permanent short. We report on the development of a gas puff system that uses helium to clear such particles from the detector. Experiments with varying nozzle designs, backing pressures, puff durations, and exit flow orientations have obtained an optimal configuration that effectively removes particles from a 25 cm^2 area. Dust removal from next step tokamaks will be required to meet regulatory dust limits. A tripolar grid of fine interdigitated traces has been designed that generates an electrostatic travelling wave for conveying dust particles to a ``drain.'' First trials have shown particle motion in optical microscope images. [1] C. H. Skinner et al., J. Nucl. Mater., 376 (2008) 29.
A rain pixel recovery algorithm for videos with highly dynamic scenes.
Jie Chen; Lap-Pui Chau
2014-03-01
Rain removal is a very useful and important technique in applications such as security surveillance and movie editing. Several rain removal algorithms have been proposed these years, where photometric, chromatic, and probabilistic properties of the rain have been exploited to detect and remove the rainy effect. Current methods generally work well with light rain and relatively static scenes, when dealing with heavier rainfall in dynamic scenes, these methods give very poor visual results. The proposed algorithm is based on motion segmentation of dynamic scene. After applying photometric and chromatic constraints for rain detection, rain removal filters are applied on pixels such that their dynamic property as well as motion occlusion clue are considered; both spatial and temporal informations are then adaptively exploited during rain pixel recovery. Results show that the proposed algorithm has a much better performance for rainy scenes with large motion than existing algorithms.
Wang, Xiansheng; Ni, Jiaheng; Pang, Shuo; Li, Ying
2017-04-01
A electrocoagulation (EC)/peanut shell (PS) adsorption coupling technique was studied for the removal of malachite green (MG) in our present work. The addition of an appropriate PS dosage (5 g/L) resulted in remarkable increase in the removal efficiency of MG at lower current density and shorter operating time compared with the conventional EC process. The effect of current density, pH of MG solution, dosage of PS and initial concentration of MG were also investigated. The maximum removal efficiency of MG was 98% under optimum conditions in 5 min. And it was 23% higher than that in EC process. Furthermore, the unit energy demand (UED) and the unit electrode material demand (UEMD) were calculated and discussed. The results demonstrated that the EC/PS adsorption coupling method achieved a reduction of 94% UED and UEMD compared with EC process.
NASA Astrophysics Data System (ADS)
Barsbay, Murat; Kavaklı, Pınar Akkaş; Güven, Olgun
2010-03-01
A novel polymeric ligand exchanger (PLE) was prepared for the removal of phosphate ions from water. 2,2'-dipyridylamine (DPA), a bidentate ligand forming compound with high coordination capacity with a variety of metal ions was bound to glycidyl methacrylate (GMA) grafted polypropylene/polyethylene (PP/PE) nonwoven fabric synthesized by radiation-induced grafting technique. DPA attachment on epoxy ring of GMA units was tested in different solvents, i.e. methanol, ethanol, dioxane and dimethylsulfoxide (DMSO). The highest amount of modification was achieved in dioxane. In order to prepare the corresponding PLE for the removal of phosphate, DPA-immobilized fabric was loaded with Cu(II) ions. Phosphate adsorption experiments were performed in batch mode at different pH (5-9) and phosphate concentrations. The fabric was found to be effective for the removal of phosphate ions. At every stage of preparation and use, the nonwoven fabric was characterized by thermal (i.e. DSC and TGA) and spectroscopic (FTIR) methods. Competitive adsorption experiments were also carried out using two solutions with different concentration levels at pH 7 to see the effect of competing ions. Phosphate adsorption was found to be effective and selective from solutions having trace amounts of competitive anions. It is expected that the novel PLE synthesized can be used for the removal of phosphate ions in low concentrations over a large range of pH.
Guo, Weijie; Li, Zhu; Cheng, Shuiping; Liang, Wei; He, Feng; Wu, Zhenbin
2014-01-01
To examine the performance of a constructed wetland system on stormwater runoff and domestic sewage (SRS) treatment in central east China, two parallel pilot-scale integrated constructed wetland (ICW) systems were operated for one year. Each ICW consisted of a down-flow bed, an up-flow bed and a horizontal subsurface flow bed. The average removal rates of chemical oxygen demand (CODCr), total suspended solids (TSS), ammonia (NH4(+)-N), total nitrogen (TN) and total phosphorus (TP) were 63.6, 91.9, 38.7, 43.0 and 70.0%, respectively, and the corresponding amounts of pollutant retention were approximately 368.3, 284.9, 23.2, 44.6 and 5.9 g m(-2) yr(-1), respectively. High hydraulic loading rate (HLR) of 200 mm/d and low water temperatures (<15 °C) resulted in significant decrease in removals for TP and NH4(+)-N, but had no significant effects on removals of COD and TSS. These results indicated that the operation of this ICW at higher HLR (200 mm/d) might be effective and feasible for TSS and COD removal, but for acceptable removal efficiencies of nitrogen and phosphorus it should be operated at lower HLR (100 mm/d). This kind of ICW could be employed as an effective technique for SRS treatment.
NASA Technical Reports Server (NTRS)
Gordon, H. R.
1981-01-01
For an estimation of the concentration of phytoplankton pigments in the oceans on the basis of Nimbus-7 CZCS imagery, it is necessary to remove the effects of the intervening atmosphere from the satellite imagery. The principle effect of the atmosphere is a loss in contrast caused by the addition of a substantial amount of radiance (path radiance) to that scatttered out of the water. Gordon (1978) has developed a technique which shows considerable promise for removal of these atmospheric effects. Attention is given to the correction algorithm, and its application to CZCS imagery. An alternate method under study for affecting the atmospheric correction requires a knowledge of 'clear water' subsurface upwelled radiance as a function of solar angle and pigment concentration.
Technologies for Arsenic Removal from Water: Current Status and Future Perspectives
Nicomel, Nina Ricci; Leus, Karen; Folens, Karel; Van Der Voort, Pascal; Du Laing, Gijs
2015-01-01
This review paper presents an overview of the available technologies used nowadays for the removal of arsenic species from water. Conventionally applied techniques to remove arsenic species include oxidation, coagulation-flocculation, and membrane techniques. Besides, progress has recently been made on the utility of various nanoparticles for the remediation of contaminated water. A critical analysis of the most widely investigated nanoparticles is presented and promising future research on novel porous materials, such as metal organic frameworks, is suggested. PMID:26703687
Technologies for Arsenic Removal from Water: Current Status and Future Perspectives.
Nicomel, Nina Ricci; Leus, Karen; Folens, Karel; Van Der Voort, Pascal; Du Laing, Gijs
2015-12-22
This review paper presents an overview of the available technologies used nowadays for the removal of arsenic species from water. Conventionally applied techniques to remove arsenic species include oxidation, coagulation-flocculation, and membrane techniques. Besides, progress has recently been made on the utility of various nanoparticles for the remediation of contaminated water. A critical analysis of the most widely investigated nanoparticles is presented and promising future research on novel porous materials, such as metal organic frameworks, is suggested.
Decoster, Laura C; Burns, Matthew F; Swartz, Erik E; Murthi, Dinakar S; Hernandez, Adam E; Vailas, James C; Isham, Linda L
2012-04-15
Descriptive laboratory study. To determine whether the placement of padding beneath the occiput after helmet removal is an effective intervention to maintain neutral sagittal cervical spine alignment in a position comparable with the helmeted condition. Current on-field recommendations for managing football athletes with suspected cervical spine injuries call for face mask removal, rather than helmet removal, because the combination of helmet and shoulder pads has been shown to maintain neutral cervical alignment. Therefore, in cases when helmet removal is required, recommendations also call for shoulder pad removal. Because removal of equipment causes motion, any technique that postpones the need to remove the shoulder pads would reduce prehospital motion. Four lateral radiographs of 20 male participants were obtained (age = 23.6 ± 2.7 years). Radiographs of participants wearing shoulder pads and helmet were first obtained. The helmet was removed and radiographs of participants with occipital padding were obtained immediately and 20 minutes later and finally without occipital padding. Cobb angle measurements for C2-C6 vertebral segments were determined by an orthopedic spine surgeon blinded to the study's purpose. Intraobserver reliability was determined using intraclass coefficient analysis. Measurements were analyzed using a 1×4 repeated-measures analysis of variance and post hoc pairwise comparisons with Bonferroni correction. Intraobserver analysis showed excellent reliability (intraclass correlation = 1.0; 95% confidence interval [CI], 0.999-1.0). Repeated-measures analysis of variance detected significant differences (F(3,17) = 13.34; P < 0.001). Pairwise comparisons revealed no differences in cervical alignment (all measurements reported reflect lordosis) when comparing the baseline helmeted condition (10.1° ± 8.7°; 95% CI, 6.0-14.1) with the padded conditions. Measurements taken after removal of occipital padding (14.4° ± 8.1°; 95% CI, 10.6-18.2) demonstrated a significant increase in cervical lordosis compared with the immediate padded measurement (9.5° ± 6.9°; 95% CI, 6.3-12.7; P = 0.011) and the 20-minute padded measurement (6.5° ± 6.8°; 95% CI, 3.4-9.7; P < 0.001). Although face mask removal remains the standard, if it becomes necessary to remove the football helmet in the field, occipital padding (along with full body/head immobilization techniques) may be used to limit cervical lordosis, allowing safe delay of shoulder pad removal.
NASA Astrophysics Data System (ADS)
Parvin, Fahmida; Sultana, Nargis; Habib, S. M. Ahsan; Bhoumik, Nikhil Chandra
2017-11-01
The aim of this study is to find out the facile and effective pretreatment technique to enhance the capacity of jute stick powder (JSP) in adsorbing dye from raw textile effluent. Hence, different pretreatment techniques, i.e., radiation treatment, alkali treatment, ammonia treatment, steam treatment and CaCl2 treatment were applied to JSP and the adsorbing performance were examined for synthetic dye solutions (Blue FCL and Red RL dye). Different gamma radiation doses were applied on JSP and optimum dye removal efficiency was found at 500 krad in removing these two dyes (50 ppm) from solutions. Among the different pretreatment techniques, gamma irradiated JSP (500 Krad) exhibits highest dye uptake capacity for RED RL dye, whereas steam-treated JSP shows highest performance in adsorbing blue FCL dye. Subsequently, we applied the gamma irradiated and steam-treated JSP on real textile effluent (RTE) and these two techniques shows potentiality in adsorbing dye from raw textile effluent and in reducing BOD5, COD load and TOC to some extent as well. Fourier transform infrared spectroscopy (FTIR) analysis also proved that dye has been adsorbed on pretreated JSP.
Andreetti, Claudio; D'Andrilli, Antonio; Venuta, Federico; Rendina, Erino Angelo
2013-01-01
We describe an original technique for correction of pectus carinatum (PC) through a limited sub-axillary incision by chondrectomy and the use of costal cartilages articulated bars to stabilize the chest wall. We have developed this technique in order to improve the cosmetic results in the surgical treatment of even complex sterno-chondral deformities. The surgical incision is made along the lateral edge of the pectoralis major muscle in the sub-axillary region and its length is related to the number of costal cartilages to be treated. This technique is principally indicated for asymmetric PC with unilateral deformities of the costal cartilages, but its application can be extended to bilateral alteration of the parasternal cartilages by performing the sub-axillary incision bilaterally. When more than four cartilages are removed, the chest is stabilized by articulated bars made using cylindrical fragments obtained by the division of the removed costal cartilages. This thoracoplasty technique performed with a minimally invasive sub-axillary access is simple and safe. It allows the effective treatment of severe PC with either unilateral asymmetric or bilateral costal cartilages deformities, avoiding the median sternal incision and the use of the metallic bar. PMID:23111343
Andreetti, Claudio; D'Andrilli, Antonio; Venuta, Federico; Rendina, Erino Angelo
2013-02-01
We describe an original technique for correction of pectus carinatum (PC) through a limited sub-axillary incision by chondrectomy and the use of costal cartilages articulated bars to stabilize the chest wall. We have developed this technique in order to improve the cosmetic results in the surgical treatment of even complex sterno-chondral deformities. The surgical incision is made along the lateral edge of the pectoralis major muscle in the sub-axillary region and its length is related to the number of costal cartilages to be treated. This technique is principally indicated for asymmetric PC with unilateral deformities of the costal cartilages, but its application can be extended to bilateral alteration of the parasternal cartilages by performing the sub-axillary incision bilaterally. When more than four cartilages are removed, the chest is stabilized by articulated bars made using cylindrical fragments obtained by the division of the removed costal cartilages. This thoracoplasty technique performed with a minimally invasive sub-axillary access is simple and safe. It allows the effective treatment of severe PC with either unilateral asymmetric or bilateral costal cartilages deformities, avoiding the median sternal incision and the use of the metallic bar.
[Steam and air co-injection in removing TCE in 2D-sand box].
Wang, Ning; Peng, Sheng; Chen, Jia-Jun
2014-07-01
Steam and air co-injection is a newly developed and promising soil remediation technique for non-aqueous phase liquids (NAPLs) in vadose zone. In this study, in order to investigate the mechanism of the remediation process, trichloroethylene (TCE) removal using steam and air co-injection was carried out in a 2-dimensional sandbox with different layered sand structures. The results showed that co-injection perfectly improved the "tailing" effect compared to soil vapor extraction (SVE), and the remediation process of steam and air co-injection could be divided into SVE stage, steam strengthening stage and heat penetration stage. Removal ratio of the experiment with scattered contaminant area was higher and removal speed was faster. The removal ratios from the two experiments were 93.5% and 88.2%, and the removal periods were 83.9 min and 90.6 min, respectively. Steam strengthened the heat penetration stage. The temperature transition region was wider in the scattered NAPLs distribution experiment, which reduced the accumulation of TCE. Slight downward movement of TCE was observed in the experiment with TCE initially distributed in a fine sand zone. And such downward movement of TCE reduced the TCE removal ratio.
Quantum chemical calculation of the equilibrium structures of small metal atom clusters
NASA Technical Reports Server (NTRS)
Kahn, L. R.
1982-01-01
Metal atom clusters are studied based on the application of ab initio quantum mechanical approaches. Because these large 'molecular' systems pose special practical computational problems in the application of the quantum mechanical methods, there is a special need to find simplifying techniques that do not compromise the reliability of the calculations. Research is therefore directed towards various aspects of the implementation of the effective core potential technique for the removal of the metal atom core electrons from the calculations.
Use of fractography and sectioning techniques to study fracture mechanisms
NASA Technical Reports Server (NTRS)
Van Stone, R. H.; Cox, T. B.
1976-01-01
Recent investigations of the effect of microstructure on the fracture mechanisms and fracture toughness of steels, aluminum alloys, and titanium alloys have used standard fractographic techniques and a sectioning technique on specimens plastically deformed to various strains up to fracture. The specimens are prepared metallographically for observation in both optical and electron beam instruments. This permits observations to be made about the fracture mechanism as it occurs in thick sections and helps remove speculation from the interpretation of fractographic features. This technique may be used in conjunction with other standard techniques such as extraction replicas and microprobe analyses. Care must be taken to make sure that the microstructural features which are observed to play a role in the fracture process using the sectioning technique can be identified with fractography.
Processing techniques for global land 1-km AVHRR data
Eidenshink, Jeffery C.; Steinwand, Daniel R.; Wivell, Charles E.; Hollaren, Douglas M.; Meyer, David
1993-01-01
The U.S. Geological Survey's (USGS) Earth Resources Observation Systems (EROS) Data Center (EDC) in cooperation with several international science organizations has developed techniques for processing daily Advanced Very High Resolution Radiometer (AVHRR) 1-km data of the entire global land surface. These techniques include orbital stitching, geometric rectification, radiometric calibration, and atmospheric correction. An orbital stitching algorithm was developed to combine consecutive observations acquired along an orbit by ground receiving stations into contiguous half-orbital segments. The geometric rectification process uses an AVHRR satellite model that contains modules for forward mapping, forward terrain correction, and inverse mapping with terrain correction. The correction is accomplished by using the hydrologic features coastlines and lakes from the Digital Chart of the World. These features are rasterized into the satellite projection and are matched to the AVHRR imagery using binary edge correlation techniques. The resulting coefficients are related to six attitude correction parameters: roll, roll rate, pitch, pitch rate, yaw, and altitude. The image can then be precision corrected to a variety of map projections and user-selected image frames. Because the AVHRR lacks onboard calibration for the optical wavelengths, a series of time-variant calibration coefficients derived from vicarious calibration methods and are used to model the degradation profile of the instruments. Reducing atmospheric effects on AVHRR data is important. A method has been develop that will remove the effects of molecular scattering and absorption from clear sky observations, using climatological measurements of ozone. Other methods to remove the effects of water vapor and aerosols are being investigated.
Yu, Jiangdong; Jiang, Chunyan; Guan, Qingqing; Ning, Ping; Gu, Junjie; Chen, Qiuling; Zhang, Junmin; Miao, Rongrong
2018-03-01
Biochar derived from waste water hyacinth was prepared and modified by ZnO nanoparticles for Cr(VI) removal from aqueous solution with the aim of Cr(VI) removal and management of waste biomass. The effect of carbonization temperature (500-800 °C), ZnO content (10-50 wt%) loaded on biochar and contact time (0.17-14 h) on the Cr(VI) removal were investigated. It was found that higher than 95% removal efficiency of Cr(VI) can be achieved with the biochar loaded 30 wt% ZnO. The adsorption kinetics of the sorbent is consistent with the pseudo-second-order kinetic model and adsorption isotherm follows the Langmuir model with maximum adsorption capacity of 43.48 mg g -1 for Cr(VI). Multiple techniques such as XRD, XPS, SEM, EDX and FT-IR were performed to investigate the possible mechanisms involved in the Cr (VI) adsorption. The results show that there is precipitation between chromium ions and Zn oxide. Furthermore, the ZnO nanoparticles acts as photo-catalyst to generate photo-generated electrons to enhance the reduction of Cr(VI) to Cr(III). The as-prepared ZnO/BC possess good recyclability and the removal ratio remained at about 70% in the fifth cycle, which suggests that both contaminants removal and effective management of water hyacinth can be achieved by the approach. Copyright © 2017 Elsevier Ltd. All rights reserved.
Minimally invasive surgical technique for tethered surgical drains
Hess, Shane R; Satpathy, Jibanananda; Waligora, Andrew C; Ugwu-Oju, Obinna
2017-01-01
A feared complication of temporary surgical drain placement is from the technical error of accidentally suturing the surgical drain into the wound. Postoperative discovery of a tethered drain can frequently necessitate return to the operating room if it cannot be successfully removed with nonoperative techniques. Formal wound exploration increases anesthesia and infection risk as well as cost and is best avoided if possible. We present a minimally invasive surgical technique that can avoid the morbidity associated with a full surgical wound exploration to remove a tethered drain when other nonoperative techniques fail. PMID:28400669
A Novel Technique for Inferior Vena Cava Filter Extraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Johnston, Edward William, E-mail: ed.johnston@doctors.org.uk; Rowe, Luke Michael Morgan; Brookes, Jocelyn
Inferior vena cava (IVC) filters are used to protect against pulmonary embolism in high-risk patients. Whilst the insertion of retrievable IVC filters is gaining popularity, a proportion of such devices cannot be removed using standard techniques. We describe a novel approach for IVC filter removal that involves snaring the filter superiorly along with the use of flexible forceps or laser devices to dissect the filter struts from the caval wall. This technique has used to successfully treat three patients without complications in whom standard techniques failed.
Removing non-stationary noise in spectrum sensing using matrix factorization
NASA Astrophysics Data System (ADS)
van Bloem, Jan-Willem; Schiphorst, Roel; Slump, Cornelis H.
2013-12-01
Spectrum sensing is key to many applications like dynamic spectrum access (DSA) systems or telecom regulators who need to measure utilization of frequency bands. The International Telecommunication Union (ITU) recommends a 10 dB threshold above the noise to decide whether a channel is occupied or not. However, radio frequency (RF) receiver front-ends are non-ideal. This means that the obtained data is distorted with noise and imperfections from the analog front-end. As part of the front-end the automatic gain control (AGC) circuitry mainly affects the sensing performance as strong adjacent signals lift the noise level. To enhance the performance of spectrum sensing significantly we focus in this article on techniques to remove the noise caused by the AGC from the sensing data. In order to do this we have applied matrix factorization techniques, i.e., SVD (singular value decomposition) and NMF (non-negative matrix factorization), which enables signal space analysis. In addition, we use live measurement results to verify the performance and to remove the effects of the AGC from the sensing data using above mentioned techniques, i.e., applied on block-wise available spectrum data. In this article it is shown that the occupancy in the industrial, scientific and medical (ISM) band, obtained by using energy detection (ITU recommended threshold), can be an overestimation of spectrum usage by 60%.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katsenovich, Yelena; Gonzalez, Nathan; Moreno-Pastor, Carol
2012-07-01
Injection of reactive gases, such as NH{sub 3}, is an innovative technique to mitigate uranium contamination in soil for a vadose zone (VZ) contaminated with radionuclides. A series of experiments were conducted to examine the effect of the concentration ratio of silicon to aluminum in the presence of various bicarbonate concentrations on the coprecipitation process of U(VI). The concentration of Al in all tests remained unchanged at 2.8 mM. Experiments showed that the removal efficiency of uranium was not significantly affected by the different bicarbonate and U(VI) concentrations tested. For the lower Si:Al molar ratios of 2:1 and 18:1, themore » removal efficiency of uranium was relatively low (≤ 8%). For the Si:Al molar ratio of 35:1, the removal efficiency of uranium was increased to an average of ∼82% for all bicarbonate concentrations tested. At higher Si:Al molar ratios (53:1 and above), a relatively high removal efficiency of U(VI), approximately 85% and higher, was observed. These results demonstrate that the U(VI) removal efficiency is more affected by the Si:Al molar ratio than by the bicarbonate concentration in solution. The results of this experiment are promising for the potential implementation of NH{sub 3} gas injection for the remediation of U(VI) -contaminated VZ. (authors)« less
Overview of innovative remediation of emerging contaminants
NASA Astrophysics Data System (ADS)
Keller, A. A.; Adeleye, A. S.; Huang, Y.; Garner, K.
2015-12-01
The application of nanotechnology in drinking water treatment and pollution cleanup is promising, as demonstrated by a number of field-based (pilot and full scale) and bench scale studies. A number of reviews exist for these nanotechnology-based applications; but to better illustrate its importance and guide its development, a direct comparison between traditional treatment technologies and emerging approaches using nanotechnology is needed. In this review, the performances of traditional technologies and nanotechnology for water treatment and environmental remediation were compared with the goal of providing an up-to-date reference on the state of treatment techniques for researchers, industry, and policy makers. Pollutants were categorized into broad classes, and the most cost-effective techniques (traditional and nanotechnology-based) in each category reported in the literature were compared. Where information was available, cost and environmental implications of both technologies were also compared. Traditional treatment technologies were found to currently offer the most cost-effective choices for removal of several common pollutants from drinking water and polluted sites. Nano-based techniques may however become important in complicated remediation conditions and meeting increasingly stringent water quality standards, especially in removal of emerging pollutants and low levels of contaminants. We also discuss challenges facing environmental application of nanotechnology were also discussed and potential solutions.
Ge, Jing; Yang, Chi; Zheng, Jia-Wei; He, Dong-Mei; Zheng, Ling-Yan; Hu, Ying-Kai
2014-11-01
Piezosurgery has been used widely in oral and maxillofacial surgery, but there has been no report systematically describing an osteotomy method with piezosurgery for complicated mandibular third molar removal. The aim of this study was to introduce 4 osteotomy methods using piezosurgery and evaluate their effects. A retrospective study was conducted of patients with a complicated impacted mandibular third molar requiring extraction. The predictor variable was the extraction technique. Four osteotomy methods using piezosurgery were tested according to different impaction types: method 1 involved complete bone removal; method 2 involved segmental bone removal; method 3 involved bone removal combined with tooth splitting; and method 4 involved block bone removal. Outcome variables were success rate, operative time, major complications (including nerve injury, mandible fracture, severe hematoma, or severe edema), and serious pyogenic infection. Data were analyzed using descriptive statistics. The study was composed of 55 patients with 74 complicated impacted mandibular third molars. All impacted mandibular third molars were removed successfully. The average surgical time was 15 minutes (range, 8 to 26 minutes). Thirty-eight molars (51.4%) were extracted by method 1, 18 molars (24.3%) by method 2, 12 molars (16.2%) by method 3, and 6 molars (8.1%) by method 4. Two cases (2.7%) developed postoperative infections and recovered within 1 week using drainage and antibiotic administration. The 4 osteotomy methods with piezosurgery provide effective ways of removing complicated impacted mandibular third molars. Copyright © 2014 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.
Canali, Lyz Cristina Furquim; Duque, Jussaro Alves; Vivan, Rodrigo Ricci; Bramante, Clovis Monteiro; Só, Marcus Vinícius Reis; Duarte, Marco Antonio Hungaro
2018-04-19
To compare, by Micro-CT and confocal laser scanning microscopy (CLSM), the ability of the Wave One Gold and Wave One systems to remove filling material from mesial canals of mandibular molars, effective time spent; quantity of extruded material, and percentage of sealer in the dentinal tubules after retreatment and re-obturation procedures. Ten first mandibular molars (n = 20 mesial canals) were prepared and filled with gutta-percha and Endofill sealer mixed with Rhodamine B dye using the single cone technique. After 7 days, the canals were scanned using a high-definition micro-computer tomography with 19-mm voxel size and divided into two groups (n = 10) according to the system used in retreatment: group 1, Wave One (WO), and group 2, Wave One Gold (WG). After removing filling material with the primary file of each system, the WO 40/.08 and WG 35/.06 files were used. After using each file, a new scanning was performed and the residual filling material and extruded filling material were measured. The effective time spent to remove the canal filling was measured after each instrument. After retreatment, the teeth were re-obturated with gutta-percha and AH Plus sealer mixed with fluorescein dye using the single-cone technique. The roots were sectioned at 2, 4 and 6 mm and analysed by CLSM to measure the percentage of remaining sealer and the sealer of the new root canal filling. The data were statistically compared (P < 0.05). Both systems presented a similar volume of filling material remaining in the canals after the use of the two instruments, similar residual and new material in the dentinal tubules, and similar extrusion of material (P > 0.05). When using WO 25, the operator spent significantly less effective time than when using WG 25 (P < 0.05); however, use of WG 35 and WO 40 required a similar time to remove filling material from the canals (P > 0.05). Neither of the two systems removed all the filling material. The WG system presented similar ability in removing filling and extruded material in comparison with WO system. The effective time spent was shorter for WO 25 than for WG 25. Wave One Gold can be an alternative to perform retreatment considering that in comparison with Wave One, there was no difference in filling material removal capacity and extruded materials. There was only difference in the effective time spent, in which the operator spent more time with WG 25 than with WO 25.
Lasers for tattoo removal: a review.
Choudhary, Sonal; Elsaie, Mohamed L; Leiva, Angel; Nouri, Keyvan
2010-09-01
Tattoos have existed and have been used as an expression of art by man for ages-and so have the techniques to remove them. Lasers based on the principle of selective photothermolysis are now being used to remove black as well as colorful tattoos with varying successes. The commonly used lasers for tattoo removal are the Q-switched 694-nm ruby laser, the Q-switched 755-nm alexandrite laser, the 1,064-nm Nd:YAG laser, and the 532-nm Nd:YAG laser. Newer techniques and methods are evolving in tattoo removal with lasers. Choosing the right laser for the right tattoo color is necessary for a successful outcome. Our review aims to understand the principles of laser tattoo removal and their applications for different types and colors of tattoos. The review also highlights the complications that can occur such as dyspigmentation, allergic reactions, epidermal debris, ink darkening, and so on, in this process and how to prevent them.
Endoscopic-assisted disruption of urinary calculi using a holmium:YAG laser in standing horses.
Judy, Carter E; Galuppo, Larry D
2002-01-01
To describe a technique for endoscope-assisted disruption and removal of urinary calculi using a holmium:YAG laser in sedated, standing horses. Retrospective study. Six horses with urinary calculi. A holmium:YAG laser was used to disrupt naturally occurring urinary calculi in horses (4 geldings, 1 stallion, 1 mare). Ischial urethrotomy was performed in male horses to provide a portal for the endoscope and laser fiber. Calculus fragments were removed by a combination of lavage, transendoscopic basket snare removal, forceps, and digital manipulation. Ischial urethrotomies healed by second intention. Follow-up was obtained by recheck examination and telephone interview of owners. No major operative or postoperative complications occurred. Two calculi (1 stallion and 1 mare) were fragmented by a combination of laser ablation and manual disruption with a lithotrite. Postoperative dysuria occurred in the mare, but resolved after 1 month. Mean (+/- SD) follow-up was 306 +/- 149 days; no other complications were reported. Calcium carbonate urinary calculi (up to 15 cm in diameter) in horses can be effectively fragmented with a holmium:YAG laser. It is not known if this technique would be completely effective for larger calculi or extremely dense calculi. Calculus disruption by an endoscopically assisted holmium:YAG laser offers a minimally invasive method that can be performed in standing horses and that minimizes patient risk. Copyright 2002 by The American College of Veterinary Surgeons
Selective removal of uranium ions from contaminated waters using modified-X nanozeolite.
Shakur, H R; Rezaee Ebrahim Saraee, Kh; Abdi, M R; Azimi, G
2016-12-01
In order to efficiently remove of uranium anionic species (which are the most dominant species of uranium in natural water at neutral pH) from contaminated waters, nano-NaX zeolite was synthesized and then modified using various divalent cations (Mg 2+ , Ca 2+ , Mn 2+ ) and ZnO nanoparticles (from 1.7 to 10.3wt%). Different characterization techniques of XRF, XRD, FE-SEM, TEM, FT-IR, and AAS were used to characterize the final synthesized absorbents. Sorption experiments by batch technique were done to study the effect of solid-liquid ratio, initial uranium concentration, contact time and temperature under neutral condition of pH and presence of all anions and cations which are available in the waters. Results showed that although nano-NaX zeolite due to its negative framework charge had a low sorption capacity for adsorption of uranium anionic species, but modification of parent nano-NaX zeolite with ZnO nanoparticles and various cations effectively improved its uranium adsorption capacity. Also, results showed that under optimum condition of pH=7.56, contact time of 60min at 27°C with solid-liquid ratio of 20g/L a maximum uranium removal efficiency of 99.7% can be obtained in the presence of all anions and cations which are available in the drinking waters by NaX/ZnO nanocomposite. Copyright © 2016 Elsevier Ltd. All rights reserved.
Ardao, Inés; Magnin, Delphine; Agathos, Spiros N
2015-10-01
Microbial laccases are powerful enzymes capable of degrading lignin and other recalcitrant compounds including endocrine disrupting chemicals (EDCs). Efficient EDC removal on an industrial scale requires robust, stable, easy to handle and cost-effective immobilized biocatalysts. In this direction, magnetic biocatalysts are attractive due to their easy separation through an external magnetic field. Recently, a bioinspired immobilization technique that mimics the natural biomineralization reactions in diatoms has emerged as a fast and versatile tool for generating robust, cheap, and highly stable (nano) biocatalysts. In this work, bioinspired formation of a biotitania matrix is triggered on the surface of magnetic particles in the presence of laccase in order to produce laccase-biotitania (lac-bioTiO2 ) biocatalysts suitable for environmental applications using a novel, fast and versatile enzyme entrapment technique. Highly active lac-bioTiO2 particles have been produced and the effect of different parameters (enzyme loading, titania precursor concentration, pH, duration of the biotitania formation, and laccase adsorption steps) on the apparent activity yield of these biocatalysts were evaluated, the concentration of the titania precursor being the most influential. The lac-bioTiO2 particles were able to catalyze the removal of bisphenol A, 17α-ethinylestradiol and diclofenac in a mixture of six model EDCs and retained 90% of activity after five reaction cycles and 60% after 10 cycles. © 2015 Wiley Periodicals, Inc.
Daneshvar, N; Oladegaragoze, A; Djafarzadeh, N
2006-02-28
Electrocoagulation (EC) is one of the most effective techniques to remove color and organic pollutants from wastewater, which reduces the sludge generation. In this paper, electrocoagulation has been used for the removal of color from solutions containing C. I. Basic Red 46 (BR46) and C. I. Basic Blue 3 (BB3). These dyes are used in the wool and blanket factories for fiber dyeing. The effect of operational parameters such as current density, initial pH of the solution, time of electrolysis, initial dye concentration and solution conductivity were studied in an attempt to reach higher removal efficiency. The findings in this study shows that an increase in the current density up to 60-80 A m(-2) enhanced the color removal efficiency, the electrolysis time was 5 min and the range of pH was determined between 5.5 and 8.5 for two mentioned dye solutions. It was found that for, the initial concentration of dye in solutions should not be higher than 80 mg l(-1) in order to achieve a high color removal percentage. The optimum conductivity was found to be 8 mS cm(-1), which was adjusted using proper amount of NaCl with the dye concentration of 50 mg l(-1). Electrical energy consumption in the above conditions for the decolorization of the dye solutions containing BR46 and BB3 were 4.70 kWh(kgdye removed)(-1) and 7.57 kWh(kgdye removed)(-1), respectively. Also, during the EC process under the optimized conditions, the COD decreased by more than 75% and 99% in dye solutions containing BB3 and BR46, respectively.
Noise removing in encrypted color images by statistical analysis
NASA Astrophysics Data System (ADS)
Islam, N.; Puech, W.
2012-03-01
Cryptographic techniques are used to secure confidential data from unauthorized access but these techniques are very sensitive to noise. A single bit change in encrypted data can have catastrophic impact over the decrypted data. This paper addresses the problem of removing bit error in visual data which are encrypted using AES algorithm in the CBC mode. In order to remove the noise, a method is proposed which is based on the statistical analysis of each block during the decryption. The proposed method exploits local statistics of the visual data and confusion/diffusion properties of the encryption algorithm to remove the errors. Experimental results show that the proposed method can be used at the receiving end for the possible solution for noise removing in visual data in encrypted domain.
Cyclic process for producing methane from carbon monoxide with heat removal
Frost, Albert C.; Yang, Chang-lee
1982-01-01
Carbon monoxide-containing gas streams are converted to methane by a cyclic, essentially two-step process in which said carbon monoxide is disproportionated to form carbon dioxide and active surface carbon deposited on the surface of a catalyst, and said carbon is reacted with steam to form product methane and by-product carbon dioxide. The exothermic heat of reaction generated in each step is effectively removed during each complete cycle so as to avoid a build up of heat from cycle-to-cycle, with particularly advantageous techniques being employed for fixed bed, tubular and fluidized bed reactor operations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Foltz, K.; Landsberger, S.; Srinivasan, B.
1994-12-31
A method for the separation of radionuclides with Z greater than 88, from lower-level radioactive wastes (liquid scintillation cocktail or LSC wastes), is described. The method is liquid-liquid extraction (LLX) and demulsification. The actinide elements are removed from the LSC wastes by extraction into an aqueous phase after the cocktail has been demulsified. The aqueous and organic phases are separated, then the wastes type remaining may be incinerated. Future experiments will be performed to study the effects of pH and temperature and to extend the study to wastes containing americium.
Cornelis, Marie A.; Scheffler, Nicole R.; Mahy, Pierre; Siciliano, Sergio; De Clerck, Hugo J.; Tulloch, J.F. Camilla
2009-01-01
Purpose Skeletal anchorage systems are increasingly used in orthodontics. This article describes the techniques of placement and removal of modified surgical miniplates used for temporary orthodontic anchorage and reports surgeons’ perceptions of their use. Patients and Methods We enrolled 97 consecutive orthodontic patients having miniplates placed as an adjunct to treatment. A total of 200 miniplates were placed by 9 oral surgeons. Patients and surgeons completed questionnaires after placement and removal surgeries. Results Fifteen miniplates needed to be removed prematurely. Antibiotics and anti-inflammatories were generally prescribed after placement but not after removal surgery. Most surgeries were performed with the patient under local anesthesia. Placement surgery lasted on average between 15 and 30 minutes per plate and was considered by the surgeons to be very easy to moderately easy. The surgery to remove the miniplates was considered easier and took less time. The patients’ chief complaint was swelling, lasting on average 5.3 ± 2.8 days after placement and 4.5 ± 2.6 days after removal. Conclusions Although miniplate placement/removal surgery requires the elevation of a flap, this was considered an easy and relatively short surgical procedure that can typically be performed with the patient under local anesthesia without complications, and it may be considered a safe and effective adjunct for orthodontic treatment. PMID:18571028
Betrayal: radio-tagged Burmese pythons reveal locations of conspecifics in Everglades National Park
Smith, Brian J.; Cherkiss, Michael S.; Hart, Kristen M.; Rochford, Michael R.; Selby, Thomas H.; Snow, Ray W; Mazzotti, Frank J.
2016-01-01
The “Judas” technique is based on the idea that a radio-tagged individual can be used to “betray” conspecifics during the course of its routine social behavior. The Burmese python (Python bivittatus) is an invasive constrictor in southern Florida, and few methods are available for its control. Pythons are normally solitary, but from December–April in southern Florida, they form breeding aggregations containing up to 8 individuals, providing an opportunity to apply the technique. We radio-tracked 25 individual adult pythons of both sexes during the breeding season from 2007–2012. Our goals were to (1) characterize python movements and determine habitat selection for betrayal events, (2) quantify betrayal rates of Judas pythons, and (3) compare the efficacy of this tool with current tools for capturing pythons, both in terms of cost per python removed (CPP) and catch per unit effort (CPUE). In a total of 33 python-seasons, we had 8 betrayal events (24 %) in which a Judas python led us to new pythons. Betrayal events occurred more frequently in lowland forest (including tree islands) than would be expected by chance alone. These 8 events resulted in the capture of 14 new individuals (1–4 new pythons per event). Our effort comparison shows that while the Judas technique is more costly than road cruising surveys per python removed, the Judas technique yields more large, reproductive females and is effective at a time of year that road cruising is not, making it a potential complement to the status quo removal effort.
NASA Astrophysics Data System (ADS)
Yang, Jiali; Lu, Lansi; Zhang, Zhu; Liao, Minhui; He, Huirong; Li, Lingxing; Chen, Jida; Chen, Shijin
2017-12-01
A novel nano-fibrous adsorbent from imino-acetic acid (IDA) and polyvinyl alcohol (PVA) mixture solution was prepared by electro-spinning technique. The nano-fibrous adsorbents with imino-acetic acid functional groups were characterized and demonstrated by fourier transform infrared spectrometry (FT-IR) and the scanning electron microscopy (SEM). The effect of the adsorbents to remove heavy metals such as lead (Pb) and copper (Cu) ions from the aqueous solution was studied. The maximum adsorption percentage (SP) of the metal ions can reach 93.08% for Cu (II) and 96.69% for Pb(II), respectively. Furthermore, it shows that the adsorption procedure of the adsorbents is spontaneous and endothermic, and adsorption rate fits well with pseudo-second-order kinetic model. Most importantly, the reusability of the nanofibers for removal of metal ions was also demonstrated to be used at least five times.
Alabresm, Amjed; Chen, Yung Pin; Decho, Alan W; Lead, Jamie
2018-07-15
Releases of crude oil and other types of oil from numerous sources can impose catastrophic physical, chemical, and biological effects on aquatic ecosystems. While currently-used oil removal techniques possess many advantages, they have inherent limitations, including low removal efficiencies and waste disposal challenges. The present study quantified the synergistic interactions of polyvinylpyrrolidone (PVP) coated magnetite nanoparticles (NP) and oil-degrading bacteria for enhanced oil removal at the laboratory scale. The results showed that at relatively high oil concentrations (375 mg L -1 ), NP alone could remove approximately 70% of lower-chain alkanes (C9-C22) and 65% of higher-chain (C23-C26), after only 1 h, when magnetic separation of NP was used. Removal efficiency did not increase significantly after that, which was likely due to saturation of the NP with oil. Microbial bioremediation, using strains of oil-degrading bacteria, removed almost zero oil immediately but 80-90% removal after 24-48 h. The combination of NPs and oil-degrading bacterial strains worked effectively to remove essentially 100% of oil within 48 h or less. This was likely due to the sorption of oil components to NPs and their subsequent utilization by bacteria as a joint Fe and C source, although the mechanisms of removal require further testing. Furthermore, results showed that the emission of selected volatile organic compounds (VOCs) and semi volatile organic compounds (SVOCs) were reduced after addition of NPs and bacteria separately. When combined, VOC and SVOC emissions were reduced by up to 80%. Copyright © 2018 Elsevier B.V. All rights reserved.
Surgical Removal of Neglected Soft Tissue Foreign Bodies by Needle-Guided Technique
Ebrahimi, Ali; Radmanesh, Mohammad; Rabiei, Sohrab; kavoussi, Hossein
2013-01-01
Introduction: The phenomenon of neglected foreign bodies is a significant cause of morbidity in soft tissue injuries and may present to dermatologists as delayed wound healing, localized cellulitis and inflammation, abscess formation, or foreign body sensation. Localization and removal of neglected soft tissue foreign bodies (STFBs) is complex due to possible inflammation, indurations, granulated tissue, and fibrotic scar. This paper describes a simple method for the quick localization and (surgical) removal of neglected STFBs using two 23-gauge needles without ultrasonographic or fluoroscopic guidance. Materials and Methods: A technique based on the use of two 23-gauge needles was used in 41 neglected STFBs in order to achieve proper localization and fixation of foreign bodies during surgery. Results: Surgical removal was successful in 38 of 41 neglected STFBs (ranging from 2–13mm in diameter). Conclusion: The cross-needle-guided technique is an office-based procedure that allows the successful surgical removal of STFBs using minimal soft tissue exploration and dissection via proper localization, fixation, and propulsion of the foreign body toward the surface of the skin. PMID:24303416
A comparative study of two different uncinectomy techniques: swing-door and classical.
Singhania, Ankit A; Bansal, Chetan; Chauhan, Nirali; Soni, Saurav
2012-01-01
The aim of this study was to determine which technique of uncinectomy, classical or swing door technique. Four hundred eighty Cases of sinusitis were selected and operated for Functional Endoscopic Sinus Surgery (FESS). Out of these, in 240 uncinectomies classical uncinectomy was done whereas in another 240 uncinectomies swing door technique was used. Initially patients were medically managed treated according to their symptoms and prior management. Patients who had received previous adequate medical management were evaluated with CT scan of the sinuses. If disease still persists than they were operated for FESS. The authors' experience indicates that Functional endoscopic sinus surgery can be performed under local or general anesthesia, as permitted or tolerated. In this review classical technique was used in 240 uncinectomies. Out of this, ethmoidal complex injury was noted in 4 cases, missed maxillary ostium syndrome (incomplete removal) was reported in 12 patients and orbital fat exposure was encountered in 5 patients. As compared to 240 uncinectomies done with swing door technique, incomplete removal was evident in 2 cases and lacrimal duct injury was reported in 3 cases. 'Evidence that underscores how this 'swing door technique' successfully combines 'the conservation goals of the anterior-to-posterior approach and anatomic virtues of the posterior-to-anterior approach to ethmoidectomy of the total 480 uncinectomies operated. Out of which 240 uncinectomies have been performed using the 'swing-door' technique. The 240 uncinectomies performed using classical technique were used as controls. The incidence of orbital penetration, incomplete removal, ethmoidal complex injury and ostium non-identification was significantly less with the new technique. Three lacrimal injuries occurred with the 'swing-door' technique compared to no injuries with classical technique. The authors recommend swing door technique as it is easy to learn, allows complete removal of the uncinate flush with the lateral nasal wall and allows easy identification of the natural ostium of the maxillary sinus without injuring the ethmoidal complex.
Wei, Meng; Chen, Jiajun; Wang, Xingwei
2016-08-01
Testing of sequential soil washing in triplicate using typical chelating agent (Na2EDTA), organic acid (oxalic acid) and inorganic weak acid (phosphoric acid) was conducted to remediate soil contaminated by heavy metals close to a mining area. The aim of the testing was to improve removal efficiency and reduce mobility of heavy metals. The sequential extraction procedure and further speciation analysis of heavy metals demonstrated that the primary components of arsenic and cadmium in the soil were residual As (O-As) and exchangeable fraction, which accounted for 60% and 70% of total arsenic and cadmium, respectively. It was determined that soil washing agents and their washing order were critical to removal efficiencies of metal fractions, metal bioavailability and potential mobility due to different levels of dissolution of residual fractions and inter-transformation of metal fractions. The optimal soil washing option for arsenic and cadmium was identified as phosphoric-oxalic acid-Na2EDTA sequence (POE) based on the high removal efficiency (41.9% for arsenic and 89.6% for cadmium) and the minimal harmful effects of the mobility and bioavailability of the remaining heavy metals. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
The liquefaction of pre-gelatinized starch was studied with various analytical techniques to determine the effects of starch molecular weight, granule structure, granule size, and mechanical depolymerization. Also, improvements were made in the chromatographic system used to characterize starch hydrolysates. Progress is reported on protein removal. The effects of pH, temperature, and ionic strength were examined for the removal of protein from a syrup stream by adsorption on a phenolic resin. Buffered systems, which maintain more stable pH values, were also examined. Mathematical modeling of the results is in progress. The pilot plant facility is complete and in operation. Starch streams containing 1% protein are being produced by the protein extraction process.
Tree-breeding technique: some effects of continuous bagging
Jonathan W. Wright
1951-01-01
In tree-breeding operations, it is standard practice to protect the tree flowers with vegetable parchment or sausage-casing bags during the pollination period so no unwanted pollen can get to them. Since the bags often damage the tree, they are usually removed as soon as the pollination period ends - within 2 or 3 weeks.
Improved determination of vector lithospheric magnetic anomalies from MAGSAT data
NASA Technical Reports Server (NTRS)
Ravat, Dhananjay
1993-01-01
Scientific contributions made in developing new methods to isolate and map vector magnetic anomalies from measurements made by Magsat are described. In addition to the objective of the proposal, the isolation and mapping of equatorial vector lithospheric Magsat anomalies, isolation of polar ionospheric fields during the period were also studied. Significant progress was also made in isolation of polar delta(Z) component and scalar anomalies as well as integration and synthesis of various techniques of removing equatorial and polar ionospheric effects. The significant contributions of this research are: (1) development of empirical/analytical techniques in modeling ionospheric fields in Magsat data and their removal from uncorrected anomalies to obtain better estimates of lithospheric anomalies (this task was accomplished for equatorial delta(X), delta(Z), and delta(B) component and polar delta(Z) and delta(B) component measurements; (2) integration of important processing techniques developed during the last decade with the newly developed technologies of ionospheric field modeling into an optimum processing scheme; and (3) implementation of the above processing scheme to map the most robust magnetic anomalies of the lithosphere (components as well as scalar).
Color masking of developmental enamel defects: a case series.
Torres, C R G; Borges, A B
2015-01-01
Developmental defects involving color alteration of enamel frequently compromise the esthetic appearance of the tooth. The resin infiltration technique represents an alternative treatment for color masking of these lesions and uniformization of tooth color. This technique is considered relatively simple and microinvasive, since only a minimal portion of enamel is removed. This article illustrates the color-masking effect with resin infiltration of fluorosis and traumatic hypomineralization lesions with a case series. The final esthetic outcomes demonstrated the ability of the resin infiltrant to mask the color of white developmental defect lesions, resulting in satisfactory clinical esthetic improvements. However, in more severe cases, the color-masking effect was not complete.
Monitoring of Low-Level Virus in Natural Waters
Sorber, Charles A.; Sagik, Bernard P.; Malina, Joseph F.
1971-01-01
The insoluble polyelectrolyte technique for concentrating virus is extended to extremely low virus levels. The effectiveness of this method employing a coliphage T2 model is a constant 20% over a range of virus levels from 103 to 10−4 plaque-forming units/ml. The efficiency of the method is dependent upon pH control during the concentration phase. Although the study was initiated to develop a method for quantitating the effectiveness of water and wastewater treatment methods for the removal of viruses from waters at low concentrations, the potential of the technique for efficient monitoring of natural waters is apparent. PMID:4940873
Bramante, Clovis Monteiro; Fidelis, Natasha Siqueira; Assumpção, Tatiana Santos; Bernardineli, Norberti; Garcia, Roberto Brandão; Bramante, Alexandre Silva; de Moraes, Ivaldo Gomes
2010-11-01
This ex vivo study evaluated the heat release, time required, and cleaning efficacy of MTwo (VDW, Munich, Germany) and ProTaper Universal Retreatment systems (Dentsply/Maillefer, Ballaigues, Switzerland) and hand instrumentation in the removal of filling material. Sixty single-rooted human teeth with a single straight canal were obturated with gutta-percha and zinc oxide and eugenol-based cement and randomly allocated to 3 groups (n = 20). After 30-day storage at 37 °C and 100% humidity, the root fillings were removed using ProTaper UR, MTwo R, or hand files. Heat release, time required, and cleaning efficacy data were analyzed statistically (analysis of variance and the Tukey test, α = 0.05). None of the techniques removed the root fillings completely. Filling material removal with ProTaper UR was faster but caused more heat release. Mtwo R produced less heat release than the other techniques but was the least efficient in removing gutta-percha/sealer. ProTaper UR and MTwo R caused the greatest and lowest temperature increase on root surface, respectively; regardless of the type of instrument, more heat was released in the cervical third. Pro Taper UR needed less time to remove fillings than MTwo R. All techniques left filling debris in the root canals. Copyright © 2010 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Mu'azu, Nuhu Dalhat; Jarrah, Nabeel; Zubair, Mukarram; Alagha, Omar
2017-09-21
Due to their industrial relevance, phenolic compounds (PC) are amongst the most common organic pollutants found in many industrial wastewater effluents. The potential detrimental health and environmental impacts of PC necessitate their removal from wastewater to meet regulatory discharge standards to ensure meeting sustainable development goals. In recent decades, one of the promising, cost-effective and environmentally benign techniques for removal of PC from water streams has been adsorption onto sewage sludge (SS)-based activated carbon (SBAC). This is attributed to the excellent adsorptive characteristics of SBAC and also because the approach serves as a strategy for sustainable management of huge quantities of different types of SS that are in continual production globally. This paper reviews conversion of SS into activated carbons and their utilization for the removal of PC from water streams. Wide ranges of topics which include SBAC production processes, physicochemical characteristics of SBAC, factors affecting PC adsorption onto SBAC and their uptake mechanisms as well as the regeneration potential of spent SBAC are covered. Although chemical activation techniques produce better SBAC, yet more research work is needed to harness advances in material science to improve the functional groups and textural properties of SBAC as well as the low performance of physical activation methods. Studies focusing on PC adsorptive performance on SBAC using continuous mode (that are more relevant for industrial applications) in both single and multi-pollutant aqueous systems to cover wide range of PC are needed. Also, the potentials of different techniques for regeneration of spent SBAC used for adsorption of PC need to be assessed in relation to overall economic evaluation within realm of environmental sustainability using life cycle assessment.
Jarrah, Nabeel; Zubair, Mukarram; Alagha, Omar
2017-01-01
Due to their industrial relevance, phenolic compounds (PC) are amongst the most common organic pollutants found in many industrial wastewater effluents. The potential detrimental health and environmental impacts of PC necessitate their removal from wastewater to meet regulatory discharge standards to ensure meeting sustainable development goals. In recent decades, one of the promising, cost-effective and environmentally benign techniques for removal of PC from water streams has been adsorption onto sewage sludge (SS)-based activated carbon (SBAC). This is attributed to the excellent adsorptive characteristics of SBAC and also because the approach serves as a strategy for sustainable management of huge quantities of different types of SS that are in continual production globally. This paper reviews conversion of SS into activated carbons and their utilization for the removal of PC from water streams. Wide ranges of topics which include SBAC production processes, physicochemical characteristics of SBAC, factors affecting PC adsorption onto SBAC and their uptake mechanisms as well as the regeneration potential of spent SBAC are covered. Although chemical activation techniques produce better SBAC, yet more research work is needed to harness advances in material science to improve the functional groups and textural properties of SBAC as well as the low performance of physical activation methods. Studies focusing on PC adsorptive performance on SBAC using continuous mode (that are more relevant for industrial applications) in both single and multi-pollutant aqueous systems to cover wide range of PC are needed. Also, the potentials of different techniques for regeneration of spent SBAC used for adsorption of PC need to be assessed in relation to overall economic evaluation within realm of environmental sustainability using life cycle assessment. PMID:28934127
Kajbafzadeh, Abdol-Mohammad; Zeinoddini, Atefeh; Ebadi, Maryam; Heidari, Reza; Tajalli, Afshin
2014-04-01
The purpose of the study is to describe our experience with the application of externalized double-J ureteral stent (DJUS) during pyeloplasty for correction of ureteropelvic junction obstruction (UPJO) in order to avoid cystoscopy for stent removal. Pyeloplasty was performed in 523 infants with UPJO using miniature pyeloplasty technique. After removing the obstructed segment, a 3-Fr. DJUS was placed into the ureter. In order to avoid cystoscopy for the removal of the stent, a feeding tube was passed through the skin and renal pelvis via a separate stab incision, connected to the DJUS and secured to the external body surface (skin), and the pyeloplasty was completed. The feeding tube along with the stent was removed after 3-4 weeks, respectively. Postoperative follow-up visits were performed 1, 3, and 6 months after the procedure. The mean operative time was 49 min (range 41-79). Patients were discharged after 17 ± 2 h (mean ± SD). No patient experienced bladder spasm or anticholinergic administration. Forty-four patients (8.4 %) experienced minor complications including non-febrile urinary tract infections and mild hematuria. No major complication including urinoma, leakage, and stent migration or displacement was observed during the follow-up period. Stent removal was tolerated by 99.8 % of patients in an outpatient setting with minimal discomfort without performing cystoscopy. Using external DJUS along with a pyelocutaneous stent extension during pyeloplasty is a safe, feasible, and beneficial technique. This technique resulted in high success rate with minimal cost and no renal injury. The non-cystoscopic stent removal and elimination of urethral catheterization following pyeloplasty are the other advantages of this technique.
Effectiveness of two synthetic fiber filters for removing white cells from AS-1 red cells.
Pikul, F J; Farrar, R P; Boris, M B; Estok, L; Marlo, D; Wildgen, M; Chaplin, H
1989-09-01
Two commercially available synthetic fiber filters were studied for their effectiveness at removing white cells (WBCs) from AS-1-preserved red cells (RBCs) stored less than or equal to 14 days. In all, 65 filtrations were performed. An automated microprocessor-controlled hydraulic system designed for use with cellulose acetate fiber filters was employed to prepare filtered RBCs before release for transfusion. Studies were also carried out on polyester fiber filters, which are designed to be used in-line during transfusion. Residual WBCs were below the accurate counting range of Coulter counters and of conventional manual chamber counts. An isosmotic ammonium chloride RBC lysis method, plus a modified chamber counting technique, permitted a 270-fold increase over the number of WBCs counted by the conventional manual method. For the polyester fiber-filtered products, residual WBCs per unit were not affected by speed of filtration, prior length of storage, or mechanical tapping during filtration. The effectiveness of WBC removal (mean 99.7%), total residual WBCs (means, 4.8 and 5.5 x 10(6], and RBC recovery (mean, 93%) was the same for both filters. The majority of residual WBCs were lymphocytes. WBC removal and RBC recovery were strikingly superior to results reported with nonfiltration methods.
Sivilotti, Paolo; Falchi, Rachele; Herrera, Jose Carlos; Škvarč, Branka; Butinar, Lorena; Sternad Lemut, Melita; Bubola, Marijan; Sabbatini, Paolo; Lisjak, Klemen; Vanzo, Andreja
2017-09-27
Early leaf removal around the cluster zone is a common technique applied in cool climate viticulture, to regulate yield components and improve fruit quality. Despite the increasing amount of information on early leaf removal and its impact on total soluble solids, anthocyanins, and polyphenols, less is known regarding aroma compounds. In order to verify the hypothesis that defoliation, applied before or after flowering, could impact the biosynthesis of thiol precursors, we performed a two year (2013 and 2014) experiment on Sauvignon blanc. We provided evidence that differential accumulation of thiol precursors in berries is affected by the timing of defoliation, and this impact was related to modifications in the biosynthetic pathway. Furthermore, the possible interaction between leaf removal treatment and seasonal weather conditions, and its effect on the biosynthesis of volatile precursors are discussed. Our results suggested that in Sauvignon blanc the relative proportion of 4-S-glutathionyl-4-methylpentan-2-one (G-4MSP) and 3-S-glutathionylhexan-1-ol (G-3SH) precursors can be affected by defoliation, and this could be related to the induction of two specific genes encoding glutathione-S-transferases (VvGST3 and VvGST5), while no significant effects on basic fruit chemical parameters, polyphenols, and methoxypyrazines were ascertained under our experimental conditions.
Computer image processing: Geologic applications
NASA Technical Reports Server (NTRS)
Abrams, M. J.
1978-01-01
Computer image processing of digital data was performed to support several geological studies. The specific goals were to: (1) relate the mineral content to the spectral reflectance of certain geologic materials, (2) determine the influence of environmental factors, such as atmosphere and vegetation, and (3) improve image processing techniques. For detection of spectral differences related to mineralogy, the technique of band ratioing was found to be the most useful. The influence of atmospheric scattering and methods to correct for the scattering were also studied. Two techniques were used to correct for atmospheric effects: (1) dark object subtraction, (2) normalization of use of ground spectral measurements. Of the two, the first technique proved to be the most successful for removing the effects of atmospheric scattering. A digital mosaic was produced from two side-lapping LANDSAT frames. The advantages were that the same enhancement algorithm can be applied to both frames, and there is no seam where the two images are joined.
Transurethral removal of a cystic urolith in a mare using a laparoscopic specimen pouch.
Williamson, A J; McKinnon, A O
2017-05-01
Cystic urolithiasis is the most common form of urolithiasis reported in horses. In contrast to the gelding or stallion, clinical disease is less common in the mare and manual removal techniques are possible because of their shorter, wider urethral anatomy. However, these manual removal techniques can be traumatic and are limited by the size of the urolith. This report describes the use of a commercial laparoscopic specimen pouch to remove a cystic urolith in a mare. This approach may allow the extraction of larger uroliths per urethra in the mare, while affording some protection to the mucosa of the bladder neck and urethra. © 2017 Australian Veterinary Association.
2014-01-01
Ni2+ is a highly toxic above 0.07 mg/L and its removal is of high significance. The biosorption of Ni2+ onto medlar male flowers (MMF) was studied in relation with the physical parameters like pH, contact time, biosorbent dosage, Ni2+ concentration and temperature. The interaction biosorbent-Ni2+ was examined by the FTIR technique. The equilibrium was achieved within 40 min and the data were well fitted by the Langmuir and Redlich-Peterson (R-P) models. The maximum Ni2+ uptake capacity was 17.073 mg/g at 25°C and the Ni2+ removal follows a pseudo-second order kinetic with activation energy of 13.3 kJ/mol. The thermodynamic parameters: ΔS°, ΔH° and ΔG° showed that the biosorption was spontaneous and endothermic. MMF was used as a post treatment technique and the biosorption was coupled with the visible light driven Ni2+ reduction over the spinel ZnMn2O4. The effect of the pH, ZnMn2O4 loading and light intensity on the photoactivity was investigated. 77.5% of Ni2+ was reduced after ~140 min under optimal conditions. The Ni2+ removal reached a rate conversion of 96% of with the coupled system biosorption/photocatalysis is very promising for the water treatment. PMID:24401700
Bioremediation of Toxic Heavy Metals: A Patent Review.
Verma, Neelam; Sharma, Rajni
2017-01-01
The global industrialization is fulfilling the demands of modern population at the cost of environmental exposure to various contaminants including heavy metals. These heavy metals affect water and soil quality. Moreover, these enter into the food chain and exhibit their lethal effects on the human health even when present at slightly higher concentration than required for normal metabolism. To the worst of their part, the heavy metals may become carcinogenic. Henceforth, the efficient removal of heavy metals is the demand of sustainable development. Remedy: Bioremediation is the 'green' imperative technique for the heavy metal removal without creating secondary metabolites in the ecosystem. The metabolic potential of several bacterial, algal, fungal as well as plant species has the efficiency to exterminate the heavy metals from the contaminated sites. Different strategies like bioaccumulation, biosorption, biotransformation, rhizofilteration, bioextraction and volatilization are employed for removal of heavy metals by the biological species. Bioremediation approach is presenting a splendid alternate for conventional expensive and inefficient methods for the heavy metal removal. The patents granted on the bioremediation of toxic heavy metals are summarized in the present manuscript which supported the applicability of bioremediation technique at commercial scale. However, the implementation of the present information and advanced research are mandatory to further explore the concealed potential of biological species to resume the originality of the environment. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.
Reduction of excess sludge production using mechanical disintegration devices.
Strünkmann, G W; Müller, J A; Albert, F; Schwedes, J
2006-01-01
The usability of mechanical disintegration techniques for the reduction of excess sludge production in the activated sludge process was investigated. Using three different disintegration devices (ultrasonic homogeniser, stirred media mill, high pressure homogeniser) and different operational parameters of the disintegration, the effect of mechanical disintegration on the excess sludge production and on the effluent quality was studied within a continuously operated, laboratory scale wastewater treatment system with pre-denitrification. Depending on the operational conditions and the disintegration device used, a reduction of excess sludge production of up to 70% was achieved. A combination of mechanical disintegration with a membrane bioreactor process with high sludge age is more energy effective concerning reduction of sludge production than with a conventional activated sludge process at lower sludge ages. Depending on the disintegration parameters, the disintegration has no, or only minor, negative effect on the soluble effluent COD and on the COD-removal capacity of the activated sludge process. Nitrogen-removal was slightly deteriorated by the disintegration, whereas the system used was not optimised for nitrogen removal before disintegration was implemented.
Effect of ozone on biopolymers in biofiltration and ultrafiltration processes.
Siembida-Lösch, Barbara; Anderson, William B; Wang, Yulang Michael; Bonsteel, Jane; Huck, Peter M
2015-03-01
The focus of this full-scale study was to determine the effect of ozone on biopolymer concentrations in biofiltration and ultrafiltration (UF) processes treating surface water from Lake Ontario. Ozonation was out of service for maintenance for 9 months, hence, it was possible to investigate ozone's action on biologically active carbon contactors (BACCs) and UF, in terms of biopolymer removal. Given the importance of biopolymers for fouling, this fraction was quantified using a chromatographic technique. Ozone pre-treatment was observed to positively impact the active biomass in biofilters. However, since an increase of the active biomass did not result in higher biopolymer removal, active biomass concentration cannot be a surrogate for biofiltration performance. It was evident that increasing empty bed contact time (EBCT) from 4 to 19 min only had a positive effect on biopolymer removal through BACCs when ozone was out of service. However, as a mass balance experiment showed, ozone-free operation resulted in higher deposition of biopolymers on a UF membrane and slight deterioration in its performance. Copyright © 2014 Elsevier Ltd. All rights reserved.
Interference Resilient Sigma Delta-Based Pulse Oximeter.
Shokouhian, Mohsen; Morling, Richard; Kale, Izzet
2016-06-01
Ambient light and optical interference can severely affect the performance of pulse oximeters. The deployment of a robust modulation technique to drive the pulse oximeter LEDs can reduce these unwanted effects and increases the resilient of the pulse oximeter against artificial ambient light. The time division modulation technique used in conventional pulse oximeters can not remove the effect of modulated light coming from surrounding environment and this may cause huge measurement error in pulse oximeter readings. This paper presents a novel cross-coupled sigma delta modulator which ensures that measurement accuracy will be more robust in comparison with conventional fixed-frequency oximeter modulation technique especially in the presence of pulsed artificial ambient light. Moreover, this novel modulator gives an extra control over the pulse oximeter power consumption leading to improved power management.
Dezawa, A; Sairyo, K
2011-05-01
The serial dilating technique used to access herniated discs at the L5-S1 space using percutaneous endoscopic discectomy (PED) via an 8 mm skin incision can possibly injure the S1 nerve root. In this paper, we describe in detail a new surgical procedure to safely access the disc and to avoid the nerve root damage. This small-incision endoscopic technique, small-incision microendoscopic discectomy (sMED), mimics microendoscopic discectomy and applies PED. The sMED approach is similar to the well-established microendoscopic discectomy technique. To secure the surgical field, a duckbill-type PED cannula is used. Following laminotomy of L5 using a high-speed drill, the ligamentum flavum is partially removed using the Kerrison rongeur. Using the curved nerve root retractor, the S1 nerve root is gradually and gently moved caudally. Following the compete retraction of the S1 nerve root to the caudal side of the herniated nucleus pulposus (HNP), the nerve root is retracted safely medially and caudally using the bill side of the duckbill PED cannula. Next, using the HNP rongeur for PED, the HNP is removed piece by piece until the nerve root is decompressed. A total of 30 patients with HNP at the L5-S1 level underwent sMED. In all cases, HNP was successfully removed and patients showed improvement following surgery. Only one patient complained of moderate radiculopathy at the final visit. No complications were encountered. We introduced a minimally invasive technique to safely remove HNP at the L5-S1 level. sMED is possibly the least invasive technique for HNP removal at the L5-S1 level. © 2011 Japan Society for Endoscopic Surgery, Asia Endosurgery Task Force and Blackwell Publishing Asia Pty Ltd.
Power, Jonathan D; Plitt, Mark; Gotts, Stephen J; Kundu, Prantik; Voon, Valerie; Bandettini, Peter A; Martin, Alex
2018-02-27
"Functional connectivity" techniques are commonplace tools for studying brain organization. A critical element of these analyses is to distinguish variance due to neurobiological signals from variance due to nonneurobiological signals. Multiecho fMRI techniques are a promising means for making such distinctions based on signal decay properties. Here, we report that multiecho fMRI techniques enable excellent removal of certain kinds of artifactual variance, namely, spatially focal artifacts due to motion. By removing these artifacts, multiecho techniques reveal frequent, large-amplitude blood oxygen level-dependent (BOLD) signal changes present across all gray matter that are also linked to motion. These whole-brain BOLD signals could reflect widespread neural processes or other processes, such as alterations in blood partial pressure of carbon dioxide (pCO 2 ) due to ventilation changes. By acquiring multiecho data while monitoring breathing, we demonstrate that whole-brain BOLD signals in the resting state are often caused by changes in breathing that co-occur with head motion. These widespread respiratory fMRI signals cannot be isolated from neurobiological signals by multiecho techniques because they occur via the same BOLD mechanism. Respiratory signals must therefore be removed by some other technique to isolate neurobiological covariance in fMRI time series. Several methods for removing global artifacts are demonstrated and compared, and were found to yield fMRI time series essentially free of motion-related influences. These results identify two kinds of motion-associated fMRI variance, with different physical mechanisms and spatial profiles, each of which strongly and differentially influences functional connectivity patterns. Distance-dependent patterns in covariance are nearly entirely attributable to non-BOLD artifacts.
A Study of a Super-Cooling Technique for Removal of Rubber from Solid-Rubber Tires.
environmental pollution . In answering these questions, an experiment is conducted to validate the concept and to determine liquid...is performed to compare the costs of the super-cooling technique with those of the brake drum lathe method of rubber removal. Safety and environmental pollution factors are also investigated and
Image-guided scapulothoracic arthroscopy for removing firearm projectiles
Ejnisman, Benno; Andreoli, Carlos Vicente; Carvalho, Cassiano Diniz; Pochini, Alberto De Castro
2014-01-01
Scapulothoracic arthroscopy is gaining recognition among arthroscopic procedures as it is considered a relatively low morbidity procedure; also, continuing studies of this technique are making it safer. Scapulothoracic arthroscopy can be used for removal of a foreign body. This case report describes the removal of a firearm projectile using image-guided arthroscopy, highlighting the anatomical aspects and characteristics of the surgical technique. In this case, the patient recovered uneventfully, with complete remission of symptoms in 30 days, returning to his usual activities within 2 months after surgery. PMID:25480137
The Fate of Trace Contaminants in a Crewed Spacecraft Cabin Environment
NASA Technical Reports Server (NTRS)
Perry, Jay L.; Kayatin, Matthew J.
2016-01-01
Trace chemical contaminants produced via equipment offgassing, human metabolic sources, and vehicle operations are removed from the cabin atmosphere by active contamination control equipment and incidental removal by other air quality control equipment. The fate of representative trace contaminants commonly observed in spacecraft cabin atmospheres is explored. Removal mechanisms are described and predictive mass balance techniques are reviewed. Results from the predictive techniques are compared to cabin air quality analysis results. Considerations are discussed for an integrated trace contaminant control architecture suitable for long duration crewed space exploration missions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sotiriadis, Charalampos; Hajdu, Steven David; Degrauwe, Sophie
With the increased use of implanted venous access devices (IVADs) for continuous long-term venous access, several techniques such as percutaneous endovascular fibrin sheath removal, have been described, to maintain catheter function. Most standard techniques do not capture the stripped fibrin sheath, which is subsequently released in the pulmonary circulation and may lead to symptomatic pulmonary embolism. The presented case describes an endovascular technique which includes stripping, capture, and removal of fibrin sheath using a novel filter device. A 64-year-old woman presented with IVAD dysfunction. Stripping was performed using a co-axial snare to the filter to capture the fibrin sheath. Themore » captured fragment was subsequently removed for visual and pathological verification. No immediate complication was observed and the patient was discharged the day of the procedure.« less
Ji, Jong-Hun; Shafi, Mohamed; Moon, Chang-Yun; Park, Sang-Eun; Kim, Yeon-Jun; Kim, Sung-Eun
2013-11-01
Arthroscopic removal, now the main treatment option, has almost replaced open surgery for treatment of resistant calcific tendinitis. In some cases of chronic calcific tendinitis of the shoulder, the calcific materials are hard and adherent to the tendon. Removal of these materials can cause significant intratendinous tears between the superficial and deep layers of the degenerated rotator cuff. Thus far, there are no established surgical techniques for removing the calcific materials while ensuring cuff integrity. Good clinical results for rotator cuff repair were achieved by using an arthroscopic suture bridge technique in patients with long-standing calcific tendinitis. Intact rotator cuff integrity and recovery of signal change on follow-up magnetic resonance imaging scans were confirmed. This is a technical note about a surgical technique and its clinical results with a review of relevant published reports. © 2013 Chinese Orthopaedic Association and Wiley Publishing Asia Pty Ltd.
NASA Astrophysics Data System (ADS)
Selvaraj, A.; Nambi, I. M.
2014-12-01
In this study, an innovative technique of ZVI mediated 'coupling of Fenton like oxidation of phenol and Cr(VI) reduction technique' was attempted. The hypothesis is that Fe3+ generated from Cr(VI) reduction process acts as electron acceptor and catalyst for Fenton's Phenol oxidation process. The Fe2+ formed from Fenton reactions can be reused for Cr(VI) reduction. Thus iron can be made to recycle between two reactions, changing back and forth between Fe2+ and Fe3+ forms, makes treatment sustainable.(Fig 1) This approach advances current Fenton like oxidation process by (i)single system removal of heavy metal and organic matter (ii)recycling of iron species; hence no additional iron required (iii)more contaminant removal to ZVI ratio (iv)eliminating sludge related issues. Preliminary batch studies were conducted at different modes i) concurrent removal ii) sequential removal. The sequential removal was found better for in-situ PRB applications. PRB was designed based on kinetic rate slope and half-life time, obtained from primary column study. This PRB has two segments (i)ZVI segment[Cr(VI)] (ii)iron species segment[phenol]. This makes treatment sustainable by (i) having no iron ions in outlet stream (ii)meeting hypothesis and elongates the life span of PRB. Sequential removal of contaminates were tested in pilot scale PRB(Fig 2) and its life span was calculated based on the exhaustion of filling material. Aqueous, sand and iron aliquots were collected at various segments of PRB and analyzed for precipitation and chemical speciation thoroughly (UV spectrometer, XRD, FTIR, electron microscope). Chemical speciation profile eliminates the uncertainties over in-situ PRB's long term performance. Based on the pilot scale PRB study, 'field level PRB wall construction' was suggested to remove heavy metal and organic compounds from Pallikaranai marshland(Fig 3)., which is contaminated with leachate coming from nearby Perungudi dumpsite. This research provides (i)deeper insight into the environmental friendly, accelerated, sustainable technique for combined removal of organic matter and heavy metal (ii)evaluation of the novel technique in PRB, which resulted in PRB's increased life span (iii)designing of PRB to remediate the marshland and its ecosystem, thus save the habitats related to it.
Papaya Seeds as A Low-Cost Sorbent for Removing Cr(VI) from The Aqueous Solution
NASA Astrophysics Data System (ADS)
Rahmawati, Atik; Marwoto, Putut; Karunia Z, Anita
2016-08-01
The presence of chromium (VI) contaminants and their toxicity in aqueous streams important environmental problems. Adsorption is one of the effective techniques that can be used for removing metal from wastewater. This research was initiated by preparing sorbent from papaya seeds and determining its functional group contents by using FT-IR. The adsorption process was carried out in a batch method. The study of adsorption aspects involved the pH, initial Cr (VI) concentration and contact time between Cr (VI) and sorbent. FT IR analysis results showed that the main functional groups are carbonyl, hydroxyl, and carboxylic. It was also found that the effective pH for Cr (VI) uptake is 2.0 and increasing contact time would increase the Cr (VI) uptake. In addition, the equilibrium was reached after 40 minutes interaction and the increase of initial chromium (VI) concentration would increase the sorbent uptake percentage. All these results indicated that papaya seed is a potential sorbent for removing Cr (VI) from aqueous solutions.
Phytoremediation Potential of Duckweed (Lemna minor L.) On Steel Wastewater.
Saha, Priyanka; Banerjee, Angela; Sarkar, Supriya
2015-01-01
An eco-friendly and cost effective technique- phytoremediation was used to remediate contaminants from waste water. This study demonstrated that phytoremediation ability of duckweed (Lemna minor L.) to remove chloride, sulphate from Biological Oxygen Treatment (BOT) waste water of coke oven plant. The BOT water quality was assessed by analyzing physico-biochemical characters--pH, Biological oxygen demand (BOD), Chemical oxygen demand (COD), total dissolved solids (TDS) and elemental concentration. It was observed that an increase in pH value indicated an improvement of water quality. The experimental results showed that, duckweed effectively removed 30% chloride, 16% sulphate and 14% TDS from BOT waste water, which suggested its ability in phytoremediation for removal of chloride and sulphate from BOT waste water. A maximum increase of 30% relative growth rate of duckweed was achieved after 21 days of experiment. Thus, it was concluded that duckweed, an aquatic plant, can be considered for treatment of the effluent discharged from the coke oven plant.
[Individual indirect bonding technique (IIBT) using set-up model].
Kyung, H M
1989-01-01
There has been much progress in Edgewise Appliance since E.H. Angle. One of the most important procedures in edgewise appliance is correct bracket position. Not only conventional edgewise appliance but also straight wire appliance & lingual appliance cannot be used more effectively unless the bracket position is accurate. Improper bracket positioning may reveal much problems during treatment, especially in finishing state. It may require either rebonding after the removal of the malpositioned bracket or the greater number of arch wire and the more complex wire bending, causing much difficulty in performing effective treatments. This made me invent Individual Indirect Bonding Technique with the use of multi-purpose set-up model in order to determine a correct and objective bracket position according to individual patients. This technique is more accurate than former indirect bonding techniques in bracket positioning, because it decides the bracket position on a set-up model which has produced to have the occlusal relationship the clinician desired. This technique is especially effective in straight wire appliance and lingual appliance in which the correct bracket positioning is indispensible.
Carroll, Patrick D; Widness, John A
2012-08-01
The development of anemia after birth in very premature, critically ill newborn infants is a universal well-described phenomenon. Although preventing anemia in this population, along with efforts to establish optimal red blood cell (RBC) transfusion and pharmacologic therapy continue to be actively investigated, the present review focuses exclusively on nonpharmacological approaches to the prevention and treatment of neonatal anemia. We begin with an overview of topics relevant to nonpharmacological techniques. These topics include neonatal and fetoplacental hemoglobin levels and blood volumes, clinical and laboratory practices applied in critically ill neonates, and current RBC transfusion practice guidelines. This is followed by a discussion of the most effective and promising nonpharmacological blood conservation strategies and techniques. Fortunately, many of these techniques are feasible in most neonatal intensive care units. When applied together, these techniques are more effective than existing pharmacotherapies in significantly decreasing neonatal RBC transfusions. They include increasing hemoglobin endowment and circulating blood volume at birth; removing less blood for laboratory testing; and optimizing nutrition. Copyright © 2012 Elsevier Inc. All rights reserved.
Artificial-intelligence-based optimization of the management of snow removal assets and resources.
DOT National Transportation Integrated Search
2002-10-01
Geographic information systems (GIS) and artificial intelligence (AI) techniques were used to develop an intelligent : snow removal asset management system (SRAMS). The system has been evaluated through a case study examining : snow removal from the ...
NASA Technical Reports Server (NTRS)
Weinberg, I.; Hsu, L. C.
1977-01-01
Increased solar cell efficiencies are attained by reduction of surface recombination and variation of impurity concentration profiles at the n(+) surface of silicon solar cells. Diagnostic techniques are employed to evaluate the effects of specific materials preparation methodologies on surface and near surface concentrations. It is demonstrated that the MOS C-V method, when combined with a bulk measurement technique, yields more complete concentration data than are obtainable by either method alone. Specifically, new solar cell MOS C-V measurements are combined with bulk concentrations obtained by a successive layer removal technique utilizing measurements of sheet resistivity and Hall coefficient.
Dinari, Mohammad; Tabatabaeian, Reyhane
2018-07-15
Finding effective methodologies for the removal of heavy metals from contaminated water are really significant. Facile and "green" techniques for adsorbents fabrication are in high demand to satisfy a wide range of practical applications. This report presents of an efficient method for preparing Fe 3 O 4 @ layered double hydroxide@ guargum bionanocomposites (GLF-BNCs). First of all, the LDH coated Fe 3 O 4 nanoparticles were simply synthesized, using ultrasonic irradiation. The citrate coated Fe 3 O 4 nanoparticles which were under negative charging and LDH nanocrystals which were charged positively make electrostatic interaction which formed a stable self-assembly component, and then guargum as a biopolymer were linked onto Fe 3 O 4 @LDH via an in situ growth method. Furthermore, the GLF-BNCs had the ability to remove cadmium ions (Cd 2+ ) from the aqueous solutions. Adsorption studies indicate that the Langmuir isotherm model and the kinetic model in pseudo-second order were appropriate for Cd(II) removal. The maximum Cd(II) adsorption capacity of the GLF8% was 258 mg g -1 . The Cd(II) was adsorbed from aqueous solutions very quickly with the contact time of 5 min by the GLF 8%, suggesting that GLF-BNCs may be a promising adsorbent for removing Cd(II) from wastewater. The effect of Fe 3 O 4 @LDH contents (2, 4 and 8 wt.%) on the thermal, physicomechanical, and morphological properties of guargum were investigated by Fourier transform infrared spectroscopy, X-ray diffraction (XRD), thermal gravimetric analysis (TGA), field emission scanning electron microscopy, transmission electron microscopy (TEM), Energy-dispersive X-ray spectroscopy and Brunauer-Emmett-Teller (BET) specific surface area techniques. The TEM results indicated that the LDH platelets are distributed within the polymer matrix. Copyright © 2018 Elsevier Ltd. All rights reserved.
Treatment of laundrette wastewater using Starbon and Fenton's reagent.
Tony, Maha A; Parker, Helen L; Clark, James H
2016-09-18
The use of grey water for a variety of purposes is gaining increased popularity as a means of preserving scarce freshwater resources. In this work, catalytic oxidation over Fenton's reagent and adsorption techniques using Starbon (mesoporous material derived from polysaccharides) has been applied. These novel techniques are used as an alternative to already studied treatments of grey water such as filtration and/or biological processes. In this study, grey water, collected from a commercial laundrette, has been used. Treatment efficiency was determined by changes in the chemical oxygen demand (COD) of the grey water. Experiments using Fenton's reagent at optimum conditions of Fe(3+) = 40 mg L(-1); H2O2 = 400 mg L(-1) and pH 3 were very successful, resulting in a 95% COD removal after 15 min. Treatment with Starbon adsorption was also effective, reaching up to 81% COD removal at pH 3 within 1 h. The combined treatment with Fenton's reagent and Starbon resulted in a 93% COD removal at a significantly reduced concentration of Fenton's reagent compared to the treatment with solo Fenton's reagent. This lower chemical dose has the advantage of reducing costs and lowering sludge generation.
Plasma Radiofrequency Discharges as Cleaning Technique for the Removal of C-W Coatings
NASA Astrophysics Data System (ADS)
Cremona, A.; Vassallo, E.; Caniello, R.; Ghezzi, F.; Grosso, G.; Laguardia, L.
2013-06-01
Erosion of materials by chemical and physical sputtering is one of the most concern of plasma wall interaction in tokamaks. In divertor ITER-like tokamaks, where carbon and tungsten are planned to be used, hydrogenated C-W mixed compounds are expected to form by erosion, transport and re-deposition processes. The selection of these materials as divertor components involves lifetime and safety issues due to tritium retention in carbon co-deposits. In this paper a cleaning technique based on RF (13.56 MHz) capacitively coupled H2/Ar plasmas has been used to remove C-W mixed materials from test specimens. The dependence of the removal rate on the H2/Ar ratio and on the plasma pressure has been investigated by X-ray photoelectron spectroscopy, atomic force microscopy, profilometry as regards the solid phase and by Langmuir probe and optical emission spectroscopy as regards the plasma phase. The best result has been obtained with a H2/Ar ratio of 10/90 at a pressure of 1 Pa. An explanation based on a synergistic effect between physical sputtering due to energetic ions and chemical etching due to radicals, together with the pressure dependence of the ion energy distribution function, is given.
NASA Astrophysics Data System (ADS)
Panetta, R. J.; Hsiao, G.
2011-12-01
Trace levels of organic contaminants such as short alcohols and terpenoids have been shown to cause spectral interference in water isotope analysis by spectroscopic techniques. The result is degraded precision and accuracy in both δD and δ18O for samples such as beverages, plant extracts or slightly contaminated waters. An initial approach offered by manufacturers is post-processing software that analyzes spectral features to identify and flag contaminated samples. However, it is impossible for this software to accurately reconstruct the water isotope signature, thus it is primarily a metric for data quality. Here, we describe a novel in-line pyrolysis system (Micro-Pyrolysis Technology, MPT) placed just prior to the inlet of a cavity ring-down spectroscopy (CRDS) analyzer that effectively removes interfering organic molecules without altering the isotope values of the water. Following injection of the water sample, N2 carrier gas passes the sample through a micro-pyrolysis tube heated with multiple high temperature elements in an oxygen-free environment. The temperature is maintained above the thermal decomposition threshold of most organic compounds (≤ 900 oC), but well below that of water (~2000 oC). The main products of the pyrolysis reaction are non-interfering species such as elemental carbon and H2 gas. To test the efficacy and applicability of the system, waters of known isotopic composition were spiked with varying amounts of common interfering alcohols (methanol, ethanol, propanol, hexanol, trans-2-hexenol, cis-3-hexanol up to 5 % v/v) and common soluble plant terpenoids (carveol, linalool, geraniol, prenol). Spiked samples with no treatment to remove the organics show strong interfering absorption peaks that adversely affect the δD and δ18O values. However, with the MPT in place, all interfering absorption peaks are removed and the water absorption spectrum is fully restored. As a consequence, the δD and δ18O values also return to their original values, demonstrating effective removal of interfering species with no isotopic fractionation during the pyrolysis. Tests of water spiked quantitatively show the MPT is most effective at removing interferences up to 1 % v/v. This level is typical for plant extracts and interstitial waters, i.e. the majority of natural samples that suffer from spectral interference.
Butler, Scott M; Smith, Nicole K; Collazo, Erika; Caltabiano, Lucia; Herbenick, Debby
2015-01-01
Pubic hair grooming and removal are common behaviors among men and women. However, little is known about the reasons for grooming, preferred pubic hairstyle of sexual partners, and symptoms associated with regular grooming. This study aims to assess pubic hair removal/grooming practices, pubic hairstyle preferences, and genital outcomes associated with pubic hair removal among men and women in a college sample. Data were gathered from 1,110 participants (671 women and 439 men) at a large public Midwestern university and a small Southern public university. Items assessed demographics, pubic hair grooming and removal practices in the past 4 weeks, reasons for pubic hair status, preference for pubic hairstyle of sexual partners, and symptoms associated with removal and grooming. Most (95%) participants had removed their pubic hair on at least one occasion in the past 4 weeks with shaving being the most commonly reported hair removal technique by women (82%) and men (49%). Women were significantly more likely to report their typical status as hair-free (50% vs. 19%; χ(2) = 165.528, P < 0.001) and men were significantly more likely to prefer a hair-free sexual partner (60% vs. 24%; χ(2) = 211.712, P < 0.001). Genital itching was experienced on at least one occasion by 80.3% of pubic hair groomers and was the most commonly reported side effect. Genital grooming and pubic hair removal are common practices among both men and women of college-age. Women are likely to report stronger associations with feelings of cleanliness, comfort, sex appeal, social norms of their peer group, and affordability as reasons for their chosen pubic hair style. Women also report more experiences with genital side effects of pubic hair removal, an expected result as women are removing pubic hair more frequently and more completely than their male counterparts. © 2014 International Society for Sexual Medicine.
Capar, I D; Arslan, H; Ertas, H; Gök, T; Saygılı, G
2015-01-01
To compare the effectiveness of ProTaper Universal retreatment instruments with continuous rotation and adaptive motion (AM; a modified reciprocating motion that combines rotational and reciprocating motion) in the removal of filling material. Mesiobuccal root canals in 36 mandibular first molars were instrumented up to size F2 with the ProTaper Universal instrument (Dentsply Maillefer, Ballaigues, Switzerland) and filled using sealer and ProTaper Universal F2 gutta-percha cones. Gutta-percha was then down-packed and the root canal backfilled using the extruder hand-piece of the Elements Obturation System (SybronEndo, Orange, CA, USA). The teeth were assigned to two groups (n = 18), and removal of the root fillings was performed using one of the following techniques: group 1) ProTaper Universal retreatment files used with rotational motion (RM) and group 2) ProTaper Universal retreatment files used with adaptive motion (AM) (600° clockwise/0° counter-clockwise to 370° clockwise/50° counter-clockwise). The teeth were sectioned, and both halves were analysed at 8 × magnification. The percentage of remaining filling material was recorded. The data were analysed statistically using the Student's t-test at a 95% confidence level (P < 0.05). There was no significant difference between the groups with respect to the total time required for retreatment (P = 0.481). The AM technique left significantly less filling material than the RM method (P = 0.013). The use of ProTaper Universal retreatment files with adaptive motion removed more filling materials from root canals than the rotational movement. © 2014 International Endodontic Journal. Published by John Wiley & Sons Ltd.
Use of Piezosurgery for removal of retrovertebral body osteophytes in anterior cervical discectomy.
Grauvogel, Juergen; Scheiwe, Christian; Kaminsky, Jan
2014-04-01
The relatively new technique of Piezosurgery is based on microvibrations, generated by the piezoelectrical effect, which results in selective bone cutting with preservation of adjacent soft tissue. To study the applicability of Piezosurgery in anterior cervical discectomy with fusion (ACDF) surgery. Prospective clinical study at the neurosurgical department of the University of Freiburg, Germany. Nine patients with cervical disc herniation and retrovertebral osteophytes who underwent ACDF surgery. Piezosurgery was evaluated with respect to practicability, safety, preciseness of bone cutting, and preservation of adjacent neurovascular tissue. Pre- and postoperative clinical and radiological data were assessed. Piezosurgery was supportively used in ACDF in nine patients with either radiculopathy or myelopathy from disc herniation or ventral osteophytes. After discectomy, osteophytes were removed with Piezosurgery to decompress the spinal canal and the foramina. Angled inserts were used, allowing for cutting even retrovertebral osteophytes. In all nine cases, Piezosurgery cut bone selectively with no damage to nerve roots, dura, or posterior longitudinal ligament. None of the patients experienced any new neurological deficit after the operation. The handling of the instrument was safe and the cut precise. Osteophytic spurs, even retrovertebral ones that generally only can be approached via corpectomies, could be safely removed because of the angled inserts through the disc space. Currently, a slightly prolonged operation time was observed for Piezosurgery. Furthermore, the design of the handpiece could be further improved to facilitate the intraoperative handling in ACDF. Piezosurgery proved to be a useful and safe technique for selective bone cutting and removal of osteophytes with preservation of neuronal and soft tissue in ACDF. In particular, the angled inserts were effective in cutting bone spurs behind the adjacent vertebra which cannot be reached with conventional rotating burs. Copyright © 2014 Elsevier Inc. All rights reserved.
Endoscopic removal of malfunctioning biliary self-expandable metallic stents.
Familiari, Pietro; Bulajic, Milutin; Mutignani, Massimiliano; Lee, Linda S; Spera, Gianluca; Spada, Cristiano; Tringali, Andrea; Costamagna, Guido
2005-12-01
Endoscopic removal of malfunctioning self-expandable metallic biliary stents (SEMS) is difficult and not well described. The aim of this study is to review the indications, the techniques, and the results of SEMS removal in a cohort of patients with malfunctioning stents. All patients who underwent an attempt at endoscopic removal of biliary SEMS over a 5-year period were retrospectively identified. The main indications for SEMS removal were the following: distal migration of the stent or impaction to the duodenum, impaction into the bile-duct wall, tissue ingrowth, and inappropriate length of the stent causing occlusion of intrahepatic ducts. SEMS were removed by using foreign-body forceps or polypectomy snares. Endoscopic removal of 39 SEMS (13 uncovered and 26 covered) was attempted in 29 patients (17 men; mean age, 66 years). SEMS extraction was attempted after a mean of 7.5 months (8.75 months standard deviation) post-SEMS insertion. Removal was successful in 20 patients (68.9%) and in 29 SEMS (74.3%). Covered SEMS were effectively removed more frequently than uncovered ones: 24 of 26 (92.3%) and 5 of 13 (38.4%), respectively (p < 0.05). No major complications were recorded. Multivariate analysis showed that the time interval between insertion and removal, SEMS length, stent-mesh design (zigzag vs. interlaced), and indication for removal were not predictive of success at stent removal. Endoscopic removal of biliary SEMS is feasible and safe in more than 70% of cases. Because only 38% of uncovered SEMS were removable, the presence of a stent covering is the only factor predictive of successful stent extraction. The presence of diffuse and severe ingrowth was the main feature limiting SEMS removal.
Martinho, Frederico C; Freitas, Lilian F; Nascimento, Gustavo G; Fernandes, Aleteia M; Leite, Fabio R M; Gomes, Ana P M; Camões, Izabel C G
2015-07-01
This clinical study was conducted to compare the effectiveness of single-file reciprocating systems and rotary systems in removing endotoxins and cultivable bacteria in endodontic retreatment. Thirty endodontically treated teeth with post-treatment apical periodontitis were selected. The specimens were divided into three groups according to the system used: WaveOne (n = 10), Reciproc instrument (n = 10), and ProTaper Universal Retreatment system (n = 10). Samples were collected before and after chemomechanical preparation. The irrigation was performed by using 2.5% sodium hypochlorite. A chromogenic limulus amebocyte lysate assay test was used to quantify endotoxins. Culture techniques were used to determine bacterial colony-forming unit counts. At baseline, endotoxins and cultivable bacteria were recovered from 100% of the root canal samples in a median value of 5.84 EU/mL and 4.98 × 10(3) CFU/mL, respectively. After CMP, no differences were found in the median percentage values of endotoxin reduction achieved with reciprocating systems-WaveOne [94.11%] and Reciproc [93.29%] and with rotary systems-ProTaper [94.98%] (P > 0.05). Both single-file reciprocating systems [WaveOne (98.27%) and Reciproc (99.54%)] and rotary system [ProTaper (98.73%)] were effective in reducing bacterial load (P > 0.05). Moreover, no differences were found among the systems tested. The Reciproc and WaveOne reciprocating systems were as effective as the ProTaper system for removal of endotoxins and bacteria in endodontic retreatment. All systems tested were effective to remove cultivable bacteria and endotoxin in endodontic retreatment. As no differences among systems were observed, it is possible to suggest that clinicians should choose the preferred technique to perform endodontic.
Türker, Onur Can; Baran, Talat
2018-01-28
The metalloid boron (B) and its compounds widely exist in the environment, and boron can have hazardous effects on plants, animals, and human beings when it is found in high concentrations in water bodies. It is difficult and costly to remove B with conventional treatment methods from drinking water. Therefore, alternative and cost-effective treatment techniques are necessary. In this study, for the first time, a novel and environmentally friendly method based on the phytoremediation ability of chitosan and duckweed (Lemna gibba L.) combination was evaluated for B removal from drinking water. Our results from batch adsorption experiment indicated that the highest B uptake capacity of chitosan bead was found as 3.18 mg/g, and we determined the optimal B sorption occurs at pH value of 7. The Langmuir isotherm and pseudo-second-order kinetic model better fitted the equilibrium obtained for B removal. B in drinking water could be reduced to less than 2.4 mg L -1 when 0.05 g of plant-based chitosan beads and 12 L. gibba fronds were used in the 4-day treatment period.
Lead (II) removal from natural soils by enhanced electrokinetic remediation.
Altin, Ahmet; Degirmenci, Mustafa
2005-01-20
Electrokinetic remediation is a very effective method to remove metal from fine-grained soils having low adsorption and buffering capacity. However, remediation of soil having high alkali and adsorption capacity via the electrokinetic method is a very difficult process. Therefore, enhancement techniques are required for use in these soil types. In this study, the effect of the presence of minerals having high alkali and cation exchange capacity in natural soil polluted with lead (II) was investigated by means of the efficiency of electrokinetic remediation method. Natural soil samples containing clinoptilolite, gypsum and calcite minerals were used in experimental studies. Moreover, a sample containing kaolinite minerals was studied to compare with the results obtained from other samples. Best results for soils bearing alkali and high sorption capacity minerals were obtained upon addition of 3 mol AcH and application of 20 V constant potential after a remediation period of 220 h. In these test conditions, lead (II) removal efficiencies for these samples varied between 60% and 70% up to 0.55 normalized distance. Under the same conditions, removal efficiencies in kaolinite sample varied between 50% and 95% up to 0.9 normalized distance.
Naeimi, Shakiba; Faghihian, Hossein
2017-07-01
As a pharmaceutical pollutant, doxycycline causes contamination when enters into the environment. In this research MIL-53(Fe), and its magnetic hybrid MIL-53(Fe)/Fe 3 O 4 were synthesized and employed for removal of doxycycline from aqueous solutions. The adsorbents were characterized by XRD, SEM, BET, FTIR, EDAX, VSM and TG-DTG technique. The effect of different variables such as DOC concentration, pH, contacting time, and adsorbent dose on the removal efficiency was studied and under optimized conditions the adsorption capacity of 322mgg -1 was obtained. The adsorption process was kinetically fast and the equilibration was attained within 30min. The used adsorbent was easily separated from the solution by applying external magnetic field. The regenerated adsorbent retained most of its initial capacity after six regeneration steps. The effect of ionic strength was studied and it was indicated that removal of doxycycline from salt-containing water with moderate ionic strengths was quite feasible. Langmuir, Freundlich, Tempkin and Dubinin-Redushkevich isotherms were employed to describe the nature of adsorption process. The sorption data was well interpreted by the Longmuir model. Copyright © 2017 Elsevier B.V. All rights reserved.
Mondal, Monoj Kumar; Garg, Ravi
2017-05-01
Arsenic contamination in water bodies is a serious problem and causes various health problems due to which US Environment Protection Agency (USEPA) set its maximum permissible limit of 10 ppb. The present review article starts with the removal of toxic arsenic using adsorbents prepared from easily available waste materials. Adsorbent either commercial or low-cost adsorbent can be used for arsenic removal but recent research was focused on the low-cost adsorbent. Preparation and activation of various adsorbents were discussed. Adsorption capacities, surface area, thermodynamic, and kinetics data of various adsorbents for As(III) and As(V) removal were compiled. Desorption followed by regeneration and reuse of adsorbents is an important step in adsorption and leads to economical process. Various desorbing and regenerating agents were discussed for arsenic decontamination from the adsorbent surface. Strong acids, bases, and salts are the main desorbing agents. Disposal of arsenic-contaminated adsorbent and arsenic waste was also a big problem because of the toxic and leaching effect of arsenic. So, arsenic waste was disposed of by proper stabilization/solidification (S/S) technique by mixing it in Portland cement, iron, ash, etc. to reduce the leaching effect.
Türker, Onur Can; Baran, Talat
2017-06-15
Boron exists in various types of water environments, and it is difficult and costly to remove B with conventional treatment methods from drinking water. Clearly, alternative and cost effective treatment techniques are imperative. In the present study, an innovative and environment friendly method based on hybrid systems consisting of various chitosan composite beads and Lemna gibba were evaluated for removal of B from drinking water. Our results from batch adsorption experiment indicated that a plant-based chitosan composite bead has a higher capacity of B removal than mineral-based chitosan composite beads. Almost 50% of total B removal was achieved using the hybrid system based on dried Lemna-chitosan composite beads and Lemna gibba combination in 4 days. Even at the high B concentration (8mgBL -1 ), B in drinking water could be reduced to less than 2.4mgL -1 when 0.05g plant-based chitosan composite beads and 12 Lemna fronds were used for 50mL test solution. Copyright © 2017 Elsevier Ltd. All rights reserved.
An effective ostrich oil bleaching technique using peroxide value as an indicator.
Palanisamy, Uma Devi; Sivanathan, Muniswaran; Radhakrishnan, Ammu Kutty; Haleagrahara, Nagaraja; Subramaniam, Thavamanithevi; Chiew, Gan Seng
2011-07-05
Ostrich oil has been used extensively in the cosmetic and pharmaceutical industries. However, rancidity causes undesirable chemical changes in flavour, colour, odour and nutritional value. Bleaching is an important process in refining ostrich oil. Bleaching refers to the removal of certain minor constituents (colour pigments, free fatty acid, peroxides, odour and non-fatty materials) from crude fats and oils to yield purified glycerides. There is a need to optimize the bleaching process of crude ostrich oil prior to its use for therapeutic purposes. The objective of our study was to establish an effective method to bleach ostrich oil using peroxide value as an indicator of refinement. In our study, we showed that natural earth clay was better than bentonite and acid-activated clay to bleach ostrich oil. It was also found that 1 hour incubation at a 150 °C was suitable to lower peroxide value by 90%. In addition, the nitrogen trap technique in the bleaching process was as effective as the continuous nitrogen flow technique and as such would be the recommended technique due to its cost effectiveness.
NASA Astrophysics Data System (ADS)
Kim, Eng-Chan; Cho, Jae-Hwan; Kim, Min-Hye; Kim, Ki-Hong; Choi, Cheon-Woong; Seok, Jong-min; Na, Kil-Ju; Han, Man-Seok
2013-03-01
This study was conducted on 20 patients who had undergone pedicle screw fixation between March and December 2010 to quantitatively compare a conventional fat suppression technique, CHESS (chemical shift selection suppression), and a new technique, IDEAL (iterative decomposition of water and fat with echo asymmetry and least squares estimation). The general efficacy and usefulness of the IDEAL technique was also evaluated. Fat-suppressed transverse-relaxation-weighed images and longitudinal-relaxation-weighted images were obtained before and after contrast injection by using these two techniques with a 1.5T MR (magnetic resonance) scanner. The obtained images were analyzed for image distortion, susceptibility artifacts and homogenous fat removal in the target region. The results showed that the image distortion due to the susceptibility artifacts caused by implanted metal was lower in the images obtained using the IDEAL technique compared to those obtained using the CHESS technique. The results of a qualitative analysis also showed that compared to the CHESS technique, fewer susceptibility artifacts and more homogenous fat removal were found in the images obtained using the IDEAL technique in a comparative image evaluation of the axial plane images before and after contrast injection. In summary, compared to the CHESS technique, the IDEAL technique showed a lower occurrence of susceptibility artifacts caused by metal and lower image distortion. In addition, more homogenous fat removal was shown in the IDEAL technique.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Feng, D.C.; Yu, Z.J.; Chen, Y.
2009-06-15
A large amount of wastewater is produced in the Lurgi coal-gasification process with the complex compounds carbon dioxide, ammonia, phenol, etc., which cause a serious environmental problem. In this paper, a novel stripper operated at elevated pressure is designed to improve the pretreatment process. In this technology, two noticeable improvements were established. First, the carbon dioxide and ammonia were removed simultaneously in a single stripper where sour gas (mainly carbon dioxide) is removed from the tower top and the ammonia vapor is drawn from the side and recovered by partial condensation. Second, the ammonia is removed before the phenol recoverymore » to reduce the pH value of the subsequent extraction units, so as the phenol removal performance of the extraction is greatly improved. To ensure the operational efficiency, some key operational parameters are analyzed and optimized though simulation. It is shown that when the top temperature is kept at 40 C and the weight ratio of the side draw to the feed is above 9%, the elevated pressures can ensure the removal efficiency of NH{sub 3} and carbon dioxide and the desired purified water as the bottom product of the unit is obtained. A real industrial application demonstrates the attractiveness of the new technique: it removes 99.9% CO{sub 2} and 99.6% ammonia, compared to known techniques which remove 66.5% and 94.4%, respectively. As a result, the pH value of the wastewater is reduced from above 9 to below 7. This ensures that the phenol removal ratio is above 93% in the following extraction units. The operating cost is lower than that of known techniques, and the operation is simplified.« less
Coverage Root after Removing Peripheral Ossifying Fibroma: 5-Year Follow-Up Case Report
Okajima, Luciana S.; Nunes, Marcelo P.; Montalli, Victor A. M.
2016-01-01
When lesions in soft tissue reach the gingival margin, they can produce aesthetic defects during its permanence and after its removal. Periodontal plastic surgery allows the correction of the gingival contour using different techniques. This paper is a case report of a peripheral ossifying fibroma removal in the interproximal area of teeth 21 and 22 in addition to root coverage of the affected area through two surgical phases: keratinized gingival tissue augmentation surgery with free gingival graft concurrent with removal of the lesion and, in a second stage, root coverage by performing coronally advanced flap technique with a follow-up of five years. The initial results achieved, which were root coverage of 100% after 6 months, promoted an adequate gingival contour and prevented the development of a mucogingival defect or a root exposure with its functional and aesthetic consequences. After five years, the results showed long term success of the techniques, where the margin remained stable with complete root coverage and tissues were stable and harmonic in color. PMID:27891263
Coverage Root after Removing Peripheral Ossifying Fibroma: 5-Year Follow-Up Case Report.
Henriques, Paulo S G; Okajima, Luciana S; Nunes, Marcelo P; Montalli, Victor A M
2016-01-01
When lesions in soft tissue reach the gingival margin, they can produce aesthetic defects during its permanence and after its removal. Periodontal plastic surgery allows the correction of the gingival contour using different techniques. This paper is a case report of a peripheral ossifying fibroma removal in the interproximal area of teeth 21 and 22 in addition to root coverage of the affected area through two surgical phases: keratinized gingival tissue augmentation surgery with free gingival graft concurrent with removal of the lesion and, in a second stage, root coverage by performing coronally advanced flap technique with a follow-up of five years. The initial results achieved, which were root coverage of 100% after 6 months, promoted an adequate gingival contour and prevented the development of a mucogingival defect or a root exposure with its functional and aesthetic consequences. After five years, the results showed long term success of the techniques, where the margin remained stable with complete root coverage and tissues were stable and harmonic in color.
NASA Technical Reports Server (NTRS)
Hotaling, S. P.
1993-01-01
Two samples from Long Duration Exposure Facility (LDEF) experiment M0003-4 were analyzed for molecular and particulate contamination prior to and following treatment with advanced satellite contamination removal techniques (CO2 gas/solid jet spray and oxygen ion beam). The pre- and post-cleaning measurements and analyses are presented. The jet spray removed particulates in seconds. The low energy reactive oxygen ion beam removed 5,000 A of photo polymerized organic hydrocarbon contamination in less than 1 hour. Spectroscopic analytical techniques were applied to the analysis of cleaning efficiency including: Fourier transform infrared, Auger, x ray photoemissions, energy dispersive x ray, and ultraviolet/visible. The results of this work suggest that the contamination studied here was due to spacecraft self-contamination enhanced by atomic oxygen plasma dynamics and solar UV radiation. These results also suggest the efficacy for the jet spray and ion beam contamination control technologies for spacecraft optical surfaces.
Removal of Pb, Zn, and Cd from contaminated soil by new washing agent from plant material.
Cao, Yaru; Zhang, Shirong; Wang, Guiyin; Huang, Qinling; Li, Ting; Xu, Xiaoxun
2017-03-01
Soil washing is an effective approach to remove soil heavy metals, and the washing agent is generally regarded as one of the primary factors in the process, but there is still a lack of efficient and eco-friendly agents for this technique. Here, we showed that four plant washing agents-from water extracts of Coriaria nepalensis (CN), Clematis brevicaudata (CB), Pistacia weinmannifolia (PW), and Ricinus communis (RC)-could be feasible agents for the removal of soil lead (Pb), zinc (Zn), and cadmium (Cd). The metal removal efficiencies of the agents increased with their concentrations from 20 to 80 g L -1 , decreased with the increasing solution pH, and presented different trends with the reaction time increasing. CN among the four agents had the highest removal efficiencies of soil Pb (62.02%) and Zn (29.18%) but owned the relatively low Cd removal efficiencies (21.59%). The Fourier transform infrared spectroscopy showed that the abilities of plant washing agents for the removal of soil heavy metals may result from bioactive substances with specific functional groups such as -COOH, -NH 2 , and -OH. Our study provided CN as the best washing agents for the remediation of contaminated soil by heavy metals.
Fan, Mingyi; Hu, Jiwei; Cao, Rensheng; Xiong, Kangning; Wei, Xionghui
2017-12-21
Reduced graphene oxide-supported nanoscale zero-valent iron (nZVI/rGO) magnetic nanocomposites were prepared and then applied in the Cu(II) removal from aqueous solutions. Scanning electron microscopy, transmission electron microscopy, X-ray photoelectron spectroscopy and superconduction quantum interference device magnetometer were performed to characterize the nZVI/rGO nanocomposites. In order to reduce the number of experiments and the economic cost, response surface methodology (RSM) combined with artificial intelligence (AI) techniques, such as artificial neural network (ANN), genetic algorithm (GA) and particle swarm optimization (PSO), has been utilized as a major tool that can model and optimize the removal processes, because a tremendous advance has recently been made on AI that may result in extensive applications. Based on RSM, ANN-GA and ANN-PSO were employed to model the Cu(II) removal process and optimize the operating parameters, e.g., operating temperature, initial pH, initial concentration and contact time. The ANN-PSO model was proven to be an effective tool for modeling and optimizing the Cu(II) removal with a low absolute error and a high removal efficiency. Furthermore, the isotherm, kinetic, thermodynamic studies and the XPS analysis were performed to explore the mechanisms of Cu(II) removal process.
Aziz, Abdul; Kim, Kwang Soo
2017-10-15
In this work, the performance of benzene, toluene, ethylbenzene, and xylene (BTEX) removal and degradation from gas, air streams on UV pretreated Fe-ZSM-5 in a batch reactor at room temperature were studied. The Fe-ZSM-5 zeolite catalyst was prepared by hydrothermal reaction method. The influence of UV pre-irradiation time on the removal of BTEX were assessed by varying the time, ranging from 15min to 60smin. Then, sustainability of the activation of the catalyst resulted by UV pretreatment was studied by the four-cycle experiment with one time UV irradiation and after each cycle irradiation followed by BTEX removal after every cycle respectively. The results of BTEX removal depicted that 30min of UV pretreatment was sufficient for complete organics removal. The UV pretreatment effect on the catalytic oxidation and the stability of the catalyst were studied by modern instrumental techniques. The novelty of the process was the sustainable reuse of catalyst with persistent VOC removal, which works on the -adsorption-oxidation-regeneration-adsorption- cycle, which was confirmed by the characterization studies of the catalyst after four runs. The results revealed that the change in the structure, stability, morphology, and removal efficiency of the catalyst during the experiments was negligible. The VOC degradation mechanism studies showed that the oxidation occurs due to the formation of free radicals as well as hydroxyl ions, so named it heterogeneous photo-Fenton oxidation. The residual materials analysis showed the complete mineralization of VOC except small amount of acetone as oxidation product. Lastly, the kinetics of the VOC removal was studied. Copyright © 2017 Elsevier B.V. All rights reserved.
Bacterial Reduction after Gutta-Percha Removal with Single vs. Multiple Instrument Systems.
Xavier, Felipe; Nevares, Giselle; Gominho, Luciana; Rodrigues, Renata; Cassimiro, Marcely; Romeiro, Kaline; Albuquerque, Diana
2018-01-01
The aim of this study was to evaluate the effectiveness of a reciprocating single-instrument system (Reciproc-REC) compared with combined continuously rotating multiple-instrument systems [D-Race (DR) and BioRace (BR)] in reducing Enterococcus faecalis (E.f.) after gutta-percha removal. Forty-six extracted human maxillary incisors were prepared and contaminated with E.f. strain (ATCC 29212) for 30 days. The samples were obturated and randomly divided into two experimental groups for gutta-percha removal ( n =23): a REC group (R50) and a DR/BR group (DR1, DR2 and BR6). A standardized irrigation with 0.9% saline solution was performed. Root canal samples were taken with paper points before (S1) and after (S2) the removal of gutta-percha to establish bacterial quantification by culture. The time required for gutta-percha removal was also recorded. Positive and negative control groups ( n =6) were used to test bacterial viability and control asepsis, respectively. Data were analysed using t -Student and one-way ANOVA tests (5% margin of error). The mean percentage of bacterial reduction was significantly higher in DR/BR group (84.2%) than in REC group (72.3%) ( P <0.05). The mean time for obturation removal was 74.00 sec in REC group and 107.53 sec in DR/BR group ( P <0.05). The combined continuously rotating multiple-instrument system was more effective in reducing bacteria after the removal of gutta-percha than the single-instrument system. None of the tested systems was able to completely eliminate root canal infection after gutta-percha removal. Thus, additional techniques should be considered.
A Novel Technique Applying Spectral Estimation to Johnson Noise Thermometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ezell, N. Dianne Bull; Britton, Chuck; Ericson, Nance
Johnson noise thermometry is one of many important measurement techniques used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the minimal electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift-free temperature measurements. The two techniques developed by Oak Ridge National Laboratory (ORNL) to remove transient and periodic EMI are briefly discussed here. Spectral estimation is a key component in the signal processing algorithm used for EMI removal and temperature calculation. The cross-power spectral density is a key component in the Johnson noise temperature computation. Applying eithermore » technique requires the simple addition of electronics and signal processing to existing resistive thermometers. With minimal installation changes, the system discussed here can be installed on existing nuclear power plants. The Johnson noise system developed is tested at three locations: ORNL, Sandia National Laboratory, and the Tennessee Valley Authority’s Kingston Fossil Plant. Each of these locations enabled improvement on the EMI removal algorithm. Finally, the conclusions made from the results at each of these locations is discussed, as well as possible future work.« less
A Novel Technique Applying Spectral Estimation to Johnson Noise Thermometry
Ezell, N. Dianne Bull; Britton, Chuck; Ericson, Nance; ...
2018-03-30
Johnson noise thermometry is one of many important measurement techniques used to monitor the safety levels and stability in a nuclear reactor. However, this measurement is very dependent on the minimal electromagnetic environment. Properly removing unwanted electromagnetic interference (EMI) is critical for accurate drift-free temperature measurements. The two techniques developed by Oak Ridge National Laboratory (ORNL) to remove transient and periodic EMI are briefly discussed here. Spectral estimation is a key component in the signal processing algorithm used for EMI removal and temperature calculation. The cross-power spectral density is a key component in the Johnson noise temperature computation. Applying eithermore » technique requires the simple addition of electronics and signal processing to existing resistive thermometers. With minimal installation changes, the system discussed here can be installed on existing nuclear power plants. The Johnson noise system developed is tested at three locations: ORNL, Sandia National Laboratory, and the Tennessee Valley Authority’s Kingston Fossil Plant. Each of these locations enabled improvement on the EMI removal algorithm. Finally, the conclusions made from the results at each of these locations is discussed, as well as possible future work.« less
UPb ages of zircon rims: A new analytical method using the air-abrasion technique
Aleinikoff, J.N.; Winegarden, D.L.; Walter, M.
1990-01-01
We present a new technique for directly dating, by conventional techniques, the rims of zircons. Several circumstances, such as a xenocrystic or inherited component in igneous zircon and metamorphic overgrowths on igneous cores, can result in grains with physically distinct age components. Pneumatic abrasion has been previously shown by Krogh to remove overgrowths and damaged areas of zircon, leaving more resistant and isotopically less disturbed parts available for analysis. A new abrader design, which is capable of very gently grinding only tips and interfacial edges of even needle-like grains, permits easy collection of abraded material for dating. Five examples demonstrate the utility of the "dust-collecting" technique, including two studies that compare conventional, ion microprobe and abrader data. Common Pb may be strongly concentrated in the outermost zones of many zircons and this Pb is not easily removed by leaching (even in weak HF). Thus, the benefit of removing only the outermost zones (and avoiding mixing of age components) is somewhat compromised by the much higher common Pb contents which result in less precise age determinations. A very brief abrasion to remove the high common Pb zones prior to collection of material for dating is selected. ?? 1990.
Ruggeri, Andrea Gennaro; Cappelletti, Martina; Fazzolari, Benedetta; Marotta, Nicola; Delfini, Roberto
2016-04-01
Traditionally, the surgical removal of tuberculum sellae meningioma (TSM) and olfactory groove meningioma (OGM) requires transcranial approaches and microsurgical techniques, but in the last decade endoscopic expanded endonasal approaches have been introduced: transcribriform for OGMs and transtuberculum-transplanum for TSM. A comparative analysis of the literature concerning the two types of surgical treatment of OGMs and TSM is, however, difficult. We conducted a literature search using the PubMed database to compare data for endoscopic and microsurgical techniques in the literature. We also conducted a retrospective analysis of selected cases from our series presenting favorable characteristics for an endoscopic approach, based on the criteria of operability of these lesions as generally accepted in the literature, and we compared the results obtained in these patients with those in the endoscopic literature. We believe that making the sample more homogeneous, the difference between microsurgical technique and endoscopic technique is no longer so striking. A greater radical removal rate, a reduced incidence of cerebrospinal fluid fistula and, especially, the possibility of removing lesions of any size are advantages of transcranial surgery; a higher percentage of improvement in visual outcome and a lower risk of a worsening of a pre-existing deficit or onset of a new deficit are advantages of the endoscopic technique. At present, the microsurgical technique is still the gold standard for the removal of the anterior cranial fossa meningiomas of all sizes, and the endoscopic technique remains a second option in certain cases. Copyright © 2016 Elsevier Inc. All rights reserved.
Denoising in digital speckle pattern interferometry using wave atoms.
Federico, Alejandro; Kaufmann, Guillermo H
2007-05-15
We present an effective method for speckle noise removal in digital speckle pattern interferometry, which is based on a wave-atom thresholding technique. Wave atoms are a variant of 2D wavelet packets with a parabolic scaling relation and improve the sparse representation of fringe patterns when compared with traditional expansions. The performance of the denoising method is analyzed by using computer-simulated fringes, and the results are compared with those produced by wavelet and curvelet thresholding techniques. An application of the proposed method to reduce speckle noise in experimental data is also presented.
Francis, Tittu; Washington, Travis; Srivastava, Karan; Moutzouros, Vasilios; Makhni, Eric C; Hakeos, William
2017-11-01
Tension band wiring (TBW) and locked plating are common treatment options for Mayo IIA olecranon fractures. Clinical trials have shown excellent functional outcomes with both techniques. Although TBW implants are significantly less expensive than a locked olecranon plate, TBW often requires an additional operation for implant removal. To choose the most cost-effective treatment strategy, surgeons must understand how implant costs and return to the operating room influence the most cost-effective strategy. This cost-effective analysis study explored the optimal treatment strategies by using decision analysis tools. An expected-value decision tree was constructed to estimate costs based on the 2 implant choices. Values for critical variables, such as implant removal rate, were obtained from the literature. A Monte Carlo simulation consisting of 100,000 trials was used to incorporate variability in medical costs and implant removal rates. Sensitivity analysis and strategy tables were used to show how different variables influence the most cost-effective strategy. TBW was the most cost-effective strategy, with a cost savings of approximately $1300. TBW was also the dominant strategy by being the most cost-effective solution in 63% of the Monte Carlo trials. Sensitivity analysis identified implant costs for plate fixation and surgical costs for implant removal as the most sensitive parameters influencing the cost-effective strategy. Strategy tables showed the most cost-effective solution as 2 parameters vary simultaneously. TBW is the most cost-effective strategy in treating Mayo IIA olecranon fractures despite a higher rate of return to the operating room. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.
The use of the venous stripper for graft removal in arterial reoperations.
Shifrin, E G; Eid, A; Anner, H; Witz, M
1987-10-01
A simple technique for removal of synthetic grafts using a standard venous stripper inside the graft is described. The method permits the simultaneous placement of a drainage tube in the canal after graft removal in cases where the graft is infected.
[Development of operation patient security detection system].
Geng, Shu-Qin; Tao, Ren-Hai; Zhao, Chao; Wei, Qun
2008-11-01
This paper describes a patient security detection system developed with two dimensional bar codes, wireless communication and removal storage technique. Based on the system, nurses and correlative personnel check code wait operation patient to prevent the defaults. The tests show the system is effective. Its objectivity and currency are more scientific and sophisticated than current traditional method in domestic hospital.
Granular activated carbon (GAC) is an effective treatment technique for the removal of some toxic organics from drinking water or wastewater, however, it can be a relatively expensive process, especially if it is designed improperly. A rapid method for the design of large-scale f...
Envelope filter sequence to delete blinks and overshoots.
Merino, Manuel; Gómez, Isabel María; Molina, Alberto J
2015-05-30
Eye movements have been used in control interfaces and as indicators of somnolence, workload and concentration. Different techniques can be used to detect them: we focus on the electrooculogram (EOG) in which two kinds of interference occur: blinks and overshoots. While they both draw bell-shaped waveforms, blinks are caused by the eyelid, whereas overshoots occur due to target localization error and are placed on saccade. They need to be extracted from the EOG to increase processing effectiveness. This paper describes off- and online processing implementations based on lower envelope for removing bell-shaped noise; they are compared with a 300-ms-median filter. Techniques were analyzed using two kinds of EOG data: those modeled from our own design, and real signals. Using a model signal allowed to compare filtered outputs with ideal data, so that it was possible to quantify processing precision to remove noise caused by blinks, overshoots, and general interferences. We analyzed the ability to delete blinks and overshoots, and waveform preservation. Our technique had a high capacity for reducing interference amplitudes (>97%), even exceeding median filter (MF) results. However, the MF obtained better waveform preservation, with a smaller dependence on fixation width. The proposed technique is better at deleting blinks and overshoots than the MF in model and real EOG signals.
Percutaneous treatment of intervertebral disc herniation.
Buy, Xavier; Gangi, Afshin
2010-06-01
Interventional radiology plays a major role in the management of symptomatic intervertebral disc herniations. In the absence of significant pain relief with conservative treatment including oral pain killers and anti-inflammatory drugs, selective image-guided periradicular infiltrations are generally indicated. The precise control of needle positioning allows optimal distribution of steroids along the painful nerve root. After 6 weeks of failure of conservative treatment including periradicular infiltration, treatment aiming to decompress or remove the herniation is considered. Conventional open surgery offers suboptimal results and is associated with significant morbidity. To achieve minimally invasive discal decompression, different percutaneous techniques have been developed. Their principle is to remove a small volume of nucleus, which results in an important reduction of intradiscal pressure and subsequently reduction of pressure inside the disc herniation. However, only contained disc herniations determined by computed tomography or magnetic resonance are indicated for these techniques. Thermal techniques such as radiofrequency or laser nucleotomy seem to be more effective than purely mechanical nucleotomy; indeed, they achieve discal decompression but also thermal destruction of intradiscal nociceptors, which may play a major role in the physiopathology of discal pain. The techniques of image-guided spinal periradicular infiltration and percutaneous nucleotomy with laser and radiofrequency are presented with emphasis on their best indications.
Results of endocapsular phacofracture debulking of hard cataracts.
Davison, James A
2015-01-01
To present a phacoemulsification technique for hard cataracts and compare postoperative results using two different ultrasonic tip motions during quadrant removal. A phacoemulsification technique which employs in situ fracture and endocapsular debulking for hard cataracts is presented. The prospective study included 56 consecutive cases of hard cataract (LOCS III NC [Lens Opacification Classification System III, nuclear color], average 4.26), which were operated using the Infiniti machine and the Partial Kelman tip. Longitudinal tip movement was used for sculpting for all cases which were randomized to receive longitudinal or torsional/interjected longitudinal (Intelligent Phaco [IP]) strategies for quadrant removal. Measurements included cumulative dissipated energy (CDE), 3 months postoperative surgically induced astigmatism (SIA), and corneal endothelial cell density (ECD) losses. No complications were recorded in any of the cases. Respective overall and longitudinal vs IP means were as follows: CDE, 51.6±15.6 and 55.7±15.5 vs 48.6±15.1; SIA, 0.36±0.2 D and 0.4±0.2 D vs 0.3±0.2 D; and mean ECD loss, 4.1%±10.8% and 5.9%±13.4% vs 2.7%±7.8%. The differences between longitudinal and IP were not significant for any of the three categories. The endocapsular phacofracture debulking technique is safe and effective for phacoemulsification of hard cataracts using longitudinal or torsional IP strategies for quadrant removal with the Infiniti machine and Partial Kelman tip.
Malhas, Ashraf N; Abuknesha, Ramadan A; Price, Robert G
2002-06-01
The use of dextran-coated activated charcoal (DCC) powder to absorb solubilising detergents from cell lysates is described. Normal embryonic epithelial cells were lysed in the presence of sodium dodecyl sulphate (SDS). The detergent was then absorbed with DCC to facilitate analysis of polycystin-1 with antibody-based methods. Polycystin-1 is a membrane protein that is involved in the pathogenesis of autosomal dominant polycystic kidney disease (ADPKD). The adverse effect of SDS on antibody-polycystin-1 binding was studied and the improvement resulting from its removal demonstrated using enzyme-linked immunosorbent assays (ELISAs). The results indicate that DCC can be used in a simple manner to remove highly reactive membrane-solubilising reagents from protein mixtures prior to immunological analysis. This procedure may be relevant to a variety of other techniques that are normally affected by detergents.
NASA Astrophysics Data System (ADS)
Filatov, I. E.; Uvarin, V. V.; Kuznetsov, D. L.
2018-05-01
The efficiency of removal of volatile organic impurities in air by a pulsed corona discharge is investigated using model mixtures. Based on the method of competing reactions, an approach to estimating the qualitative and quantitative parameters of the employed electrophysical technique is proposed. The concept of the "toluene coefficient" characterizing the relative reactivity of a component as compared to toluene is introduced. It is proposed that the energy efficiency of the electrophysical method be estimated using the concept of diversified yield of the removal process. Such an approach makes it possible to substantially intensify the determination of energy parameters of removal of impurities and can also serve as a criterion for estimating the effectiveness of various methods in which a nonequilibrium plasma is used for air cleaning from volatile impurities.
Soni-removal of nucleic acids from inclusion bodies.
Neerathilingam, Muniasamy; Mysore, Sumukh; Gandham, Sai Hari A
2014-05-23
Inclusion bodies (IBs) are commonly formed in Escherichia coli due to over expression of recombinant proteins in non-native state. Isolation, denaturation and refolding of these IBs is generally performed to obtain functional protein. However, during this process IBs tend to form non-specific interactions with sheared nucleic acids from the genome, thus getting carried over into downstream processes. This may hinder the refolding of IBs into their native state. To circumvent this, we demonstrate a methodology termed soni-removal which involves disruption of nucleic acid-inclusion body interaction using sonication; followed by solvent based separation. As opposed to conventional techniques that use enzymes and column-based separations, soni-removal is a cost effective alternative for complete elimination of buried and/or strongly bound short nucleic acid contaminants from IBs. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.
Asaithambi, P; Aziz, Abdul Raman Abdul; Sajjadi, Baharak; Daud, Wan Mohd Ashri Bin Wan
2017-02-01
In the present work, the efficiency of the sonication, electrocoagulation, and sono-electrocoagulation process for removal of pollutants from the industrial effluent of the pulp and paper industry was compared. The experimental results showed that the sono-electrocoagulation process yielded higher pollutant removal percentage compared to the sonication and electrocoagulation process alone. The effect of the operating parameters in the sono-electrocoagulation process such as electrolyte concentration (1-5 g/L), current density (1-5 A/dm 2 ), effluent pH (3-11), COD concentration (1500-6000 mg/L), inter-electrode distance (1-3 cm), and electrode combination (Fe and Al) on the color removal, COD removal, and power consumption were studied. The maximum color and COD removal percentages of 100 and 95 %, respectively, were obtained at the current density of 4 A/dm 2 , electrolyte concentration of 4 g/L, effluent pH of 7, COD concentration of 3000 mg/L, electrode combination of Fe/Fe, inter-electrode distance of 1 cm, and reaction time of 4 h, respectively. The color and COD removal percentages were analyzed by using an UV/Vis spectrophotometer and closed reflux method. The results showed that the sono-electrocoagulation process could be used as an efficient and environmental friendly technique for complete pollutant removal.
De Munck, Jan; Ermis, R Banu; Koshiro, Kenichi; Inoue, Satoshi; Ikeda, Takatsumi; Sano, Hidehiko; Van Landuyt, Kirsten L; Van Meerbeek, Bart
2007-01-01
Phase-separation within HEMA-free all-in-one dental adhesives may result in the entrapment of droplets within the adhesive resin. Strongly air-blowing prior to polymerization, can remove most of these droplets. The objective of this study was to evaluate the effect these droplets may have on the resistance of the adhesive-tooth interface to NaOCl degradation. The micro-tensile bond strength (microTBS) to enamel and dentin was determined when a HEMA-free all-in-one adhesive was applied either following a mild or strong air-blowing technique. The bonds were also exposed to an aqueous sodium hypochlorite (NaOCl) solution for 1h, following a recently introduced methodology to mimic in vivo bond degradation. This study revealed that strong air-blowing of the adhesive only resulted in a significantly higher micro-tensile bond strength (microTBS) to dentin, but not to enamel. Likewise, NaOCl only reduced the microTBS to dentin for both the mild and strong air-blowing technique, but again not the microTBS to enamel. Failure analysis by SEM clearly revealed that strong air-blowing is less effective in droplet removal when the adhesive was applied in small and narrow class-I cavities, as compared to when it was applied to flat surfaces. NaOCl did preferentially dissolve the hybrid layer at dentin, and more for the mild than for the strong air-blowing technique. A strong air-blowing procedure resulted in a more NaOCl-resistant hybrid layer, so that it can be concluded that a HEMA-free one-step adhesive definitely benefits from a strong air-blowing technique.
Population control of exotic rainbow trout in streams of a natural area park
NASA Astrophysics Data System (ADS)
Moore, Stephen E.; Larson, Gary L.; Ridley, Bromfield
1986-03-01
Expansion of the distribution of exotic rainbow trout is thought to be a leading cause for the decline of native brook trout since the 1930s in Great Smoky Mountains National Park, USA. An experimental rehabilitation project was conducted from 1976 to 1981 using backpack electrofish shockers on four remnant brook trout populations sympatric with rainbow trout. The objectives were to evaluate the effectiveness of the technique to remove the exotic rainbow trout, to determine the population responses by native brook trout, and to evaluate the usefulness of the technique for trout management in the park. Rainbow trout populations were greatly reduced in density after up to six years of electrofishing, but were not eradicated. Rainbow trout recruitment, however, was essentially eliminated. Brook trout populations responded by increasing in density (including young-of-the-year), but rates of recovery differed among streams. The maximum observed densities ir each stream occurred at the end of the project. The findings suggest that electrofishing had a major negative impact on the exotic species, which was followed by positive responses from the native species in the second and third order study streams. The technique would probably be less effective in larger (fourth-order) park streams, but as an eradication tool the technique may have its highest potential in small first order streams. Nonetheless, the technique appears useful for population control without causing undue impacts on native aquatic species, although it is labor intensive, and capture efficiency is greatly influenced by fish size and stream morphology. To completely remove the exotic fish from selected streams, different technologies will have to be explored and developed.
NASA Astrophysics Data System (ADS)
Eskandari, M.; Zakeri Khatir, M.; Khodadadi Darban, A.; Meshkini, M.
2018-04-01
This present study was conducted to investigate the effect of magnetite-bentonite nanocomposite on heavy metal removal from an effluent. For this purpose, magnetite-bentonite nanocomposite was prepared through the chemical method and characterized using x-ray diffraction (XRD) and scanning electron microscopy (SEM) techniques, followed by studying the effect of produced nanocomposite on the removal of Ni2+, Cu2+, Cd2+, and Zn2+ heavy metal ions. The results showed that adsorption capacity of magnetite-bentonite nanocomposites for the studied ions is in the order of Zn2+ > Cd2+ > Cu2+ > Ni2+. Adsorption isotherms were drawn for Ni2+, Cu2+, Cd2+, and Zn2+ cations and found that cations adsorption on nanocomposite fit into Langmuir model.
Bismuth Passivation Technique for High-Resolution X-Ray Detectors
NASA Technical Reports Server (NTRS)
Chervenak, James; Hess, Larry
2013-01-01
The Athena-plus team requires X-ray sensors with energy resolution of better than one part in 3,000 at 6 keV X-rays. While bismuth is an excellent material for high X-ray stopping power and low heat capacity (for large signal when an X-ray is stopped by the absorber), oxidation of the bismuth surface can lead to electron traps and other effects that degrade the energy resolution. Bismuth oxide reduction and nitride passivation techniques analogous to those used in indium passivation are being applied in a new technique. The technique will enable improved energy resolution and resistance to aging in bismuth-absorber-coupled X-ray sensors. Elemental bismuth is lithographically integrated into X-ray detector circuits. It encounters several steps where the Bi oxidizes. The technology discussed here will remove oxide from the surface of the Bi and replace it with nitridized surface. Removal of the native oxide and passivating to prevent the growth of the oxide will improve detector performance and insulate the detector against future degradation from oxide growth. Placing the Bi coated sensor in a vacuum system, a reduction chemistry in a plasma (nitrogen/hydrogen (N2/H2) + argon) is used to remove the oxide and promote nitridization of the cleaned Bi surface. Once passivated, the Bi will perform as a better X-ray thermalizer since energy will not be trapped in the bismuth oxides on the surface. A simple additional step, which can be added at various stages of the current fabrication process, can then be applied to encapsulate the Bi film. After plasma passivation, the Bi can be capped with a non-diffusive layer of metal or dielectric. A non-superconducting layer is required such as tungsten or tungsten nitride (WNx).
Ravani, Raghav; Chawla, Rohan; Azad, Shorya Vardhan; Gupta, Yogita; Kumar, Vinod; Kumar, Atul
2018-01-01
Purpose: The objective of this study is to describe the removal of retained intraocular foreign body (RIOFB) by bimanual pars plana vitrectomy through midline sclerotomy in phakic patients. Technique: Four eyes with RIOFB and clear lens underwent microincision vitrectomy surgery. A chandelier illumination was placed through one of the existing ports. The foreign body (FB) was localized by direct visualization (intravitreal) or indentation (pars plana), stabilized using an intraocular magnet/FB forceps introduced through a midline sclerotomy and freed of vitreous from all sides using a vitrectomy cutter through the other port bimanually, reoriented along their long axis and extracted through the midline sclerotomy. Results: All four FBs were removed successfully without slippage or damage to the clear lens. Conclusion: Chandelier illumination-assisted removal of FB through midline sclerotomy helps in easier localization, stabilization and removal, avoiding lens touch even in anteriorly located FBs such as at pars plana. PMID:29676316
Rousseau, Anne-Françoise; Damas, Pierre; Renwart, Ludovic; Amand, Théo; Erpicum, Marie; Morimont, Philippe; Dubois, Bernard; Massion, Paul B
2014-11-01
Acute respiratory distress syndrome management is currently based on lung protective ventilation. Such strategy may lead to hypercapnic acidosis. We report a case of refractory hypercapnia in a severe burn adult, treated with simplified veno-venous extracorporeal carbon dioxide removal technique. We integrated a pediatric oxygenator in a continuous veno-venous hemofiltration circuit. This technique, used during at least 96h, was feasible, sure and efficient with carbon dioxide removal rate up to 32%. Copyright © 2014 Elsevier Ltd and ISBI. All rights reserved.
Optimising Laser Tattoo Removal
Sardana, Kabir; Ranjan, Rashmi; Ghunawat, Sneha
2015-01-01
Lasers are the standard modality for tattoo removal. Though there are various factors that determine the results, we have divided them into three logical headings, laser dependant factors such as type of laser and beam modifications, tattoo dependent factors like size and depth, colour of pigment and lastly host dependent factors, which includes primarily the presence of a robust immune response. Modifications in the existing techniques may help in better clinical outcome with minimal risk of complications. This article provides an insight into some of these techniques along with a detailed account of the factors involved in tattoo removal. PMID:25949018
Innovative signal processing for Johnson Noise thermometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ezell, N. Dianne Bull; Britton, Jr, Charles L.; Roberts, Michael
This report summarizes the newly developed algorithm that subtracted the Electromagnetic Interference (EMI). The EMI performance is very important to this measurement because any interference in the form on pickup from external signal sources from such as fluorescent lighting ballasts, motors, etc. can skew the measurement. Two methods of removing EMI were developed and tested at various locations. This report also summarizes the testing performed at different facilities outside Oak Ridge National Laboratory using both EMI removal techniques. The first EMI removal technique reviewed in previous milestone reports and therefore this report will detail the second method.
Therapeutic plasma exchange: a technical and operational review.
Kaplan, Andre A
2013-02-01
Therapeutic plasma exchange (TPE) is an extracorporeal blood purification technique designed for the removal of large molecular weight substances. Examples of these substances include pathogenic autoantibodies, immune complexes, cryoglobulins, myeloma light chains, endotoxin and cholesterol containing lipoproteins. The basic premise of the treatment is that removal of these substances will allow for the reversal of the pathologic processes related to their presence. This review will cover the techniques for performing TPE, the kinetics of the removal of large molecules from the plasma and the benefits and risks of the different types of replacement fluids. Copyright © 2013 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Keller, A. A.; Adeleye, A. S.; Huang, Y.; Garner, K.
2014-12-01
The application of nanotechnology in drinking water treatment and pollution cleanup is promising, as demonstrated by a number of field-based (pilot and full scale) and bench scale studies. A number of reviews exist for these nanotechnology-based applications; but to better illustrate its importance and guide its development, a direct comparison between traditional treatment technologies and emerging approaches using nanotechnology is needed. In this review, the performances of traditional technologies and nanotechnology for water treatment and environmental remediation were compared with the goal of providing an up-to-date reference on the state of treatment techniques for researchers, industry, and policy makers. Pollutants were categorized into broad classes, and the most cost-effective techniques (traditional and nanotechnology-based) in each category reported in the literature were compared. Where information was available, cost and environmental implications of both technologies were also compared. Traditional treatment technologies were found to currently offer the most cost-effective choices for removal of several common pollutants from drinking water and polluted sites. Nano-based techniques may however become important in complicated remediation conditions and meeting increasingly stringent water quality standards, especially in removal of emerging pollutants and low levels of contaminants. We also discuss challenges facing environmental application of nanotechnology were also discussed and potential solutions.
The Big-Bubble Full Femtosecond Laser-Assisted Technique in Deep Anterior Lamellar Keratoplasty.
Buzzonetti, Luca; Petrocelli, Gianni; Valente, Paola; Iarossi, Giancarlo; Ardia, Roberta; Petroni, Sergio; Parrilla, Rosa
2015-12-01
To describe the big-bubble full femtosecond laser-assisted (BBFF) technique, which could be helpful in standardizing the big-bubble technique in deep anterior lamellar keratoplasty (DALK). Ten eyes of 10 consecutive patients affected by keratoconus underwent the BBFF technique using the 150-kHz IntraLase femtosecond laser (Intra-Lase FS Laser; Abbott Medical Optics, Inc., Santa Ana, CA). A 9-mm diameter metal mask with a single fissure 0.7 mm wide oriented at the 12-o'clock position was positioned into the cone, over the laser glass. The laser performed a ring lamellar cut (internal diameter = 3 mm; external diameter = 8 mm) 100 µm above the thinnest point, with the photodisruption effectively occurring only in the corneal stroma corresponding to the fissure to create a deep stromal channel; subsequently, an anterior side cut created an arcuate incision, from the corneal surface to the deep stromal channel on the mask's opening site. The mask was removed and the laser performed a full lamellar cut 200 µm above the thinnest point to create a lamella. After the removal of the lamella, the air needle was inserted into the stromal channel and air was injected to achieve a big bubble. The big bubble was achieved in 9 eyes (all type 1 bubbles) and all procedures were completed as DALK. Preliminary results suggest that the BBFF technique could help in standardizing the big-bubble technique in DALK, reducing the "learning curve" for surgeons who approach this technique and the risks of intraoperative complications. Copyright 2015, SLACK Incorporated.
Treatment of textile wastewater by a hybrid electrocoagulation/nanofiltration process.
Aouni, Anissa; Fersi, Cheïma; Ben Sik Ali, Mourad; Dhahbi, Mahmoud
2009-09-15
Untreated effluents from textile industries are usually highly coloured and contain a considerable amount of contaminants and pollutants. Stringent environmental regulation for the control of textile effluents is enforced in several countries. Previous studies showed that many techniques have been used for the treatment of textile wastewater, such as adsorption, biological treatment, oxidation, coagulation and/or flocculation, among them coagulation is one of the most commonly used techniques. Electrocoagulation is a process consisting in creating metallic hydroxide flocks within the wastewater by the electrodissolution of soluble anodes, usually made of iron or aluminium. This method has been practiced for most of the 20th century with limited success. In recent years, however, it started to regain importance with the progress of the electrochemical processes and the increase in environmental restrictions in effluent wastewater. This paper examines the use of electrocoagulation treatment process followed by nanofiltration process of a textile effluent sample. The electrocoagulation process was studied under several conditions such as various current densities and effect of experimental tense. Efficiencies of COD and turbidity reductions and colour removal were studied for each experiment. The electrochemical treatment was indented primarily to remove colour and COD of wastewater while nanofiltration was used to further improve the removal efficiency of the colour, COD, conductivity, alkalinity and total dissolved solids (TDS). The experimental results, throughout the present study, have indicated that electrocoagulation treatment followed by nanofiltration processes were very effective and were capable of elevating quality of the treated textile wastewater effluent.
Identification of particle-laden flow features from wavelet decomposition
NASA Astrophysics Data System (ADS)
Jackson, A.; Turnbull, B.
2017-12-01
A wavelet decomposition based technique is applied to air pressure data obtained from laboratory-scale powder snow avalanches. This technique is shown to be a powerful tool for identifying both repeatable and chaotic features at any frequency within the signal. Additionally, this technique is demonstrated to be a robust method for the removal of noise from the signal as well as being capable of removing other contaminants from the signal. Whilst powder snow avalanches are the focus of the experiments analysed here, the features identified can provide insight to other particle-laden gravity currents and the technique described is applicable to a wide variety of experimental signals.
Effect of L-ornithine 8-vasopressin on blood loss during liposuction.
Lalinde, E; Sanz, J; Ballesteros, A; Elejabeitia, J; Mesa, F; Bazán, A; Paloma, V
1995-06-01
In this comparative study, we carried out liposuction on 20 patients randomly divided in two groups to find an alternative medication to epinephrine that would not result in secondary effects at the cardiovascular level but would offer a similar vasoconstricting capacity. Also, a variation of the wet technique is described that decreases blood loss secondary to liposuction. The area to undergo liposuction is infiltrated with a cannula of our own design. Epinephrine is not used as a vasoconstrictor but rather L-ornithine 8-vasopressin at a concentration of 0.01 IU/ml chilled saline. With this new technique, the amount of blood removed is minimal, even in the case of extraction of large volumes of fat.
NASA Technical Reports Server (NTRS)
Burley, R. R.; Savino, J. M.; Wagner, L. H.; Diedrich, J. H.
1979-01-01
Wind speed profile measurements to measure the effect of a wind turbine tower on the wind velocity are presented. Measurements were made in the wake of scale models of the tower and in the wake of certain full scale components to determine the magnitude of the speed reduction (tower shadow). Shadow abatement techniques tested on the towers included the removal of diagonals, replacement of diagonals and horizontals with round cross section members, installation of elliptical shapes on horizontal members, installation of airfoils on vertical members, and application of surface roughness to vertical members.
A new approach in dry technology for non-degrading optical and EUV mask cleaning
NASA Astrophysics Data System (ADS)
Varghese, Ivin; Smith, Ben; Balooch, Mehdi; Bowers, Chuck
2012-11-01
The Eco-Snow Systems group of RAVE N.P., Inc. has developed a new cleaning technique to target several of the advanced and next generation mask clean challenges. This new technique, especially when combined with Eco-Snow Systems cryogenic CO2 cleaning technology, provides several advantages over existing methods because it: 1) is solely based on dry technique without requiring additional complementary aggressive wet chemistries that degrade the mask, 2) operates at atmospheric pressure and therefore avoids expensive and complicated equipment associated with vacuum systems, 3) generates ultra-clean reactants eliminating possible byproduct adders, 4) can be applied locally for site specific cleaning without exposing the rest of the mask or can be used to clean the entire mask, 5) removes organic as well as inorganic particulates and film contaminations, and 6) complements current techniques utilized for cleaning of advanced masks such as reduced chemistry wet cleans. In this paper, we shall present examples demonstrating the capability of this new technique for removal of pellicle glue residues and for critical removal of carbon contamination on EUV masks.
Helmet and shoulder pad removal in football players with unstable cervical spine injuries.
Dahl, Michael C; Ananthakrishnan, Dheera; Nicandri, Gregg; Chapman, Jens R; Ching, Randal P
2009-05-01
Football, one of the country's most popular team sports, is associated with the largest overall number of sports-related, catastrophic, cervical spine injuries in the United States (Mueller, 2007). Patient handling can be hindered by the protective sports equipment worn by the athlete. Improper stabilization of these patients can exacerbate neurologic injury. Because of the lack of consensus on the best method for equipment removal, a study was performed comparing three techniques: full body levitation, upper torso tilt, and log roll. These techniques were performed on an intact and lesioned cervical spine cadaveric model simulating conditions in the emergency department. The levitation technique was found to produce motion in the anterior and right lateral directions. The tilt technique resulted in motions in the posterior left lateral directions, and the log roll technique generated motions in the right lateral direction and had the largest amount of increased instability when comparing the intact and lesioned specimen. These findings suggest that each method of equipment removal displays unique weaknesses that the practitioner should take into account, possibly on a patient-by-patient basis.
In-situ monitoring of etching of bovine serum albumin using low-temperature atmospheric plasma jet
NASA Astrophysics Data System (ADS)
Kousal, J.; Shelemin, A.; Kylián, O.; Slavínská, D.; Biederman, H.
2017-01-01
Bio-decontamination of surfaces by means of atmospheric pressure plasma is nowadays extensively studied as it represents promising alternative to commonly used sterilization/decontamination techniques. The non-equilibrium atmospheric pressure plasmas were already reported to be highly effective in removal of a wide range of biological residual from surfaces. Nevertheless the kinetics of removal of biological contamination from surfaces is still not well understood as the majority of performed studies were based on ex-situ evaluation of etching rates, which did not allow investigating details of plasma action on biomolecules. This study therefore presents a real-time, in-situ ellipsometric characterization of removal of bovine serum albumin (BSA) from surfaces by low-temperature atmospheric plasma jet operated in argon. Non-linear and at shorter distances between treated samples and nozzle of the plasma jet also non-monotonic dependence of the removal rate on the treatment duration was observed. According to additional measurements focused on the determination of chemical changes of treated BSA as well as temperature measurements, the observed behavior is most likely connected with two opposing effects: the formation of a thin layer on the top of BSA deposit enriched in inorganic compounds, whose presence causes a gradual decrease of removal efficiency, and slight heating of BSA that facilitates its degradation and volatilization induced by chemically active radicals produced by the plasma.
Udovic, Metka; Lestan, Domen
2012-07-01
The environmental risk of potentially toxic metals (PTMs) in soil can be diminished by their removal. Among the available remediation techniques, soil leaching with various solutions is one of the most effective but data about the impact on soil chemical and biological properties are still scarce. We studied the effect of two common leaching agents, hydrochloric acid (HCl) and a chelating agent (EDTA) on Pb, Zn, Cd removal and accessibility and on physico-chemical and biological properties in one calcareous, pH neutral soil and one non-calcareous acidic soil. EDTA was a more efficient leachant compared to HCl: up to 133-times lower chelant concentration was needed for the same percentage (35%) of Pb removal. EDTA and HCl concentrations with similar PTM removal efficiency decreased PTM accessibility in both soils but had different impacts on soil properties. As expected, HCl significantly dissolved carbonates from calcareous soil, while EDTA leaching increased the pH of the acidic soil. Enzyme activity assays showed that leaching with HCl had a distinctly negative impact on soil microbial and enzyme activity, while leaching with EDTA had less impact. Our results emphasize the importance of considering the ecological impact of remediation processes on soil in addition to the capacity for PTM removal. Copyright © 2012 Elsevier Ltd. All rights reserved.
Raghu, S; Ahmed Basha, C
2007-10-22
This paper examines the use of chemical or electrocoagulation treatment process followed by ion-exchange process of the textile dye effluent. The dye effluent was treated using polymeric coagulant (cationic dye-fixing agent) or electrocoagulation (iron and aluminum electrode) process under various conditions such as various current densities and effect of pH. Efficiencies of COD reduction, colour removal and power consumption were studied for each process. The chemical or electrochemical treatment are indented primarily to remove colour and COD of wastewater while ion exchange is used to further improve the removal efficiency of the colour, COD, Fe concentration, conductivity, alkalinity and total dissolved solids (TDS). From the results chemical coagulation, maximum COD reduction of about 81.3% was obtained at 300 mg/l of coagulant whereas in electrocoagulation process, maximum COD removal of about 92.31% (0.25 A/dm2) was achieved with energy consumption of about 19.29 k Wh/kg of COD and 80% (1A/dm(2)) COD removal was obtained with energy consumption of about 130.095 k Wh/kg of COD at iron and aluminum electrodes, respectively. All the experimental results, throughout the present study, have indicated that chemical or electrocoagulation treatment followed by ion-exchange methods were very effective and were capable of elevating quality of the treated wastewater effluent to the reuse standard of the textile industry.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maxwell, D.P.; Richardson, C.F.
Three mercury measurement techniques were performed on synthesis gas streams before and after an amine-based sulfur removal system. The syngas was sampled using (1) gas impingers containing a nitric acid-hydrogen peroxide solution, (2) coconut-based charcoal sorbent, and (3) an on-line atomic absorption spectrophotometer equipped with a gold amalgamation trap and cold vapor cell. Various impinger solutions were applied upstream of the gold amalgamation trap to remove hydrogen sulfide and isolate oxidized and elemental species of mercury. The results from these three techniques are compared to provide an assessment of these measurement techniques in reducing gas atmospheres.
Effects of ammonium on uranium partitioning and kaolinite mineral dissolution.
Emerson, Hilary P; Di Pietro, Silvina; Katsenovich, Yelena; Szecsody, Jim
2017-02-01
Ammonia gas injection is a promising technique for the remediation of uranium within the vadose zone. It can be used to manipulate the pH of a system and cause co-precipitation processes that are expected to remove uranium from the aqueous phase and decrease leaching from the solid phase. The work presented in this paper explores the effects of ammonium and sodium hydroxide on the partitioning of uranium and dissolution of the kaolinite mineral in simplified synthetic groundwaters using equilibrium batch sorption and sequential extraction experiments. It shows that there is a significant increase in uranium removal in systems with divalent cations present in the aqueous phase but not in sodium chloride synthetic groundwaters. Further, the initial conditions of the aqueous phase do not affect the dissolution of kaolinite. However, the type of base treatment does have an effect on mineral dissolution. Published by Elsevier Ltd.
Technique of after-loading interstitial implants.
Syed, A M; Feder, B H
1977-01-01
Interstitial implants are either removable or permanent (and occasionally a combination of both). Permanent implants are generally utilized where tumors are not accessible enough to permit easy removal of sources or where accurate source distribution is less critical. They are useful for cancers of the lung, pancreas, prostate, bladder, lymph nodes, etc. Radon and gold-198 have been largely replaced by iodine-125. Our major interests are in the removable after-loading iridium-192 implant techniques. Template (steel guide) and non-template (plastic tube) techniques are utilized. Templates are preferred where the tumor volume can only be approached from one side and where accurate positioning of sources would otherwise be difficult. They are useful for cancers of the cervix, vagina, urethra, and rectum. Non-template (plastic tube) techniques are preferred where the tumor volume can be approached from at least two sides and where templates are either not feasible or not essential for accurate positioning of sources. The single needle non-template approach is useful for cancers of lip, nodes, and breast (plastic button) and for cancers of the oral cavity and oropharynx (gold button). The paired needle non-template approach is useful for cancers of the gum, retromolar trigone, and base of tongue (loop technique) and for cancers of the palate (arch technique). Procedures for each technique are described in detail.
Olive mill wastewater treatment in Jordan: A Review
NASA Astrophysics Data System (ADS)
Bawab, Abeer Al; Ghannam, Noor; Abu-Mallouh, Saida; Bozeya, Ayat; Abu-Zurayk, Rund A.; Al-Ajlouni, Yazan A.; Alshawawreh, Fida'a.; Odeh, Fadwa; Abu-Dalo, Muna A.
2018-02-01
The environmental impact of olive mill wastewater (OMW) pollution is a public concern. OMW contains high levels of phenols, organic compounds, chemical oxygen demand (COD), biological oxygen demand (BOD), microorganisms, nutrients, and toxic compounds. The treatment of OMW has been investigated by many researchers in the Mediterranean region, using several treatment techniques to remove contaminants from OMW. These techniques include chemical, biological, physiochemical, and biophysical techniques. Surfactants and some adsorbents were used in chemical techniques, anaerobic and aerobic in biological techniques, while the combined treatment methods used Electroosmosis, ozonation and electrocoagulation processes as physiochemical methods, and ultrasonic irradiation combined with aerobic biodegradation as biophysical method. The effects of OMW, whether treated or untreated, have been evaluated on both plants’ growth and soil properties. The treatment methods as well as the environmental impact of OMW in Jordan were summarized in this review.
Removal and Disposal of An Environmental Carcinogen: Asbestos
ERIC Educational Resources Information Center
Fodero, Severio D.
1977-01-01
This article details the removal and disposal of asbestos ceiling material in a Yale University building. The removal process utilized a water and wetting agent technique used by firefighters and the debris disposal was in a sanitary landfill, following federal regulations for the handling of hazardous materials. (MA)
Washing Off Polyurethane Foam Insulation
NASA Technical Reports Server (NTRS)
Burley, Richard K.; Fogel, Irving
1990-01-01
Jet of hot water removes material quickly and safely. Simple, environmentally sound technique found to remove polyurethane foam insulation from metal parts. Developed for (but not limited to) use during rebuilding of fuel system of Space Shuttle main engine, during which insulation must be removed for penetrant inspection of metal parts.
Hammond, Dennis C; Arnold, Jame F; Simon, Amy M; Capraro, Philippe A
2003-09-01
The authors present a method of treatment for gynecomastia that combines the use of two techniques of soft-tissue contouring. This method uses ultrasonic liposuction in conjunction with the pull-through technique of direct excision to effectively remove the fibrofatty tissue of the male breast and the fibrous breast bud through a single 1-cm incision. Fifteen patients were treated in this fashion, and each patient demonstrated a smooth, masculine breast contour with a well-concealed scar, which eliminates the stigma of breast surgery. The procedure is technically straightforward and provides consistent results. It is offered as an additional option for the treatment of gynecomastia.
Clinical evaluation of a chemomechanical method for caries removal in children and adolescents.
Peric, Tamara; Markovic, Dejan; Petrovic, Bojan
2009-01-01
The purpose of this study was to make a clinical comparison of the chemomechanical method for caries removal and the conventional rotary instruments technique when used in children and adolescents. The study comprised 120 patients aged 3-17 years randomized into two groups: caries were removed chemomechanically in 60 patients and 60 patients received conventional treatment with rotary instruments. The outcome variables were: clinically complete caries removal, pain during caries removal, need for local anesthesia, treatment time, preferences of patients, and clinical success of the restorations during the 12-month evaluation period. Complete caries removal was achieved in 92% of chemomechanically treated teeth and in all teeth treated with rotary instruments (p>0.05). The chemomechanical method significantly reduced the need for local anesthesia (p<0.001). Eighty-five percent of patients treated with Carisolv and 47% treated with rotary instruments were satisfied with the treatment (p<0.05). The mean time for chemomechanical caries removal was 11.2 ± 3.3 min and 5.2 ± 2.8 min for caries removal with rotary instruments (p<0.001). At the end of the 12-month evaluation period, there was no observed influence of the caries removal method on the survival of the restorations. The chemomechanical caries removal technique is an adequate alternative to the conventional rotary instruments method and is advantageous in pediatric dentistry.
Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan
2016-01-01
The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now.
Bilgin, Mehmet Selim; Baytaroğlu, Ebru Nur; Erdem, Ali; Dilber, Erhan
2016-01-01
The aim of this review was to investigate usage of computer-aided design/computer-aided manufacture (CAD/CAM) such as milling and rapid prototyping (RP) technologies for removable denture fabrication. An electronic search was conducted in the PubMed/MEDLINE, ScienceDirect, Google Scholar, and Web of Science databases. Databases were searched from 1987 to 2014. The search was performed using a variety of keywords including CAD/CAM, complete/partial dentures, RP, rapid manufacturing, digitally designed, milled, computerized, and machined. The identified developments (in chronological order), techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication are summarized. Using a variety of keywords and aiming to find the topic, 78 publications were initially searched. For the main topic, the abstract of these 78 articles were scanned, and 52 publications were selected for reading in detail. Full-text of these articles was gained and searched in detail. Totally, 40 articles that discussed the techniques, advantages, and disadvantages of CAD/CAM and RP for removable denture fabrication and the articles were incorporated in this review. Totally, 16 of the papers summarized in the table. Following review of all relevant publications, it can be concluded that current innovations and technological developments of CAD/CAM and RP allow the digitally planning and manufacturing of removable dentures from start to finish. As a result according to the literature review CAD/CAM techniques and supportive maxillomandibular relationship transfer devices are growing fast. In the close future, fabricating removable dentures will become medical informatics instead of needing a technical staff and procedures. However the methods have several limitations for now. PMID:27095912
NOx Removal from Flue Gases Using Non-Thermal Plasma
NASA Astrophysics Data System (ADS)
Takaki, Koichi
Air pollution caused by gas emission of pollutants produced from a wide range of sources including coal, oil and gas burning power plants, diesel engines, paper mills, steel and chemical production plants must be reduced drastically and urgently, as mandated by recent worldwide nation legislation which recently are being reinforced increasingly by international agreements. Non-thermal plasma in which the mean energy of electrons is substantially higher than that of the gas offer advantages in reducing energy required to remove the pollutants. The electrical energy supplied into the discharge is used preferentially to create energetic electrons which are then used to produce radicals by dissociation and ionization of the carrier gas in which the pollutants are present. These radicals are used to decompose the pollutants. There are two technologically promising techniques for generating non-thermal plasmas in atmospheric gas pressure containing the pollutants, namely electron beam irradiation and electrical discharge techniques. Both techniques are undergoing intensive and continuous development worldwide. This is done to reduce the energy requirement for pollutant removal, and therefore the associated cost, as well as to obtain a better understanding of the physical and chemical processes involved in reducing the pollutants. In the present paper only electrical discharge techniques for NOx removal from flue gases and exhaust emissions are reviewed. This paper summarizes the chemical reactions responsible for the removal of the major polluting constituents of NO and NO2 encountered in the flue gases.
Hoefler, Vaughan; Nagaoka, Hiroko; Miller, Craig S
2016-11-01
A systematic review was performed to compare the long-term survival of deep dentine caries-affected permanent teeth treated with partial-caries-removal (PCR) versus similar teeth treated with stepwise-caries-removal techniques (SWT). Clinical studies investigating long-term PCR and SWT outcomes in unrestored permanent teeth with deep dentine caries were evaluated. Failures were defined as loss of pulp vitality or restorative failures following treatment. PubMed, Web of Science, Dentistry and Oral Sciences Source, and Central databases were systematically searched. From 136 potentially relevant articles, 9 publications utilizing data from 5 studies (2 RCTs, and 3 observational case-series) reporting outcomes for 426 permanent teeth over two to ten years were analyzed. Regarding restorative failures, >88% success at two years for both techniques was reported. For loss of pulp vitality, observational studies reported >96% vitality at two years for each technique, while one RCT reported significantly higher vitality (p<0.05) at three years for PCR (96%) compared to SWT (83%). Risk of bias was high in all studies. Successful vitality and restorative outcomes for both PCR and SWT have been demonstrated at two years and beyond in permanent teeth with deep dentine caries. Partial-caries-removal may result in fewer pulpal complications over a three year period than SWT, although claims of a therapeutic advantage are based on very few, limited-quality studies. Partial-caries-removal and SWT are deep caries management techniques that reduce pulp exposure risk. Permanent teeth with deep dentine caries treated with either technique have a high likelihood for survival beyond two years. Copyright © 2016 Elsevier Ltd. All rights reserved.
Kelly, Michael E; Turner, Raymond; Gonugunta, Vivek; Rasmussen, Peter A; Woo, Henry H; Fiorella, David
2008-07-01
Microcatheters retained after Onyx (eV3 Neurovascular, Inc., Irvine, CA) embolization represent a potential source of thromboembolic complications. Catheter retention depends on the degree of Onyx reflux and vessel tortuosity. To overcome this problem, we have adapted a previously described monorail snare technique for stretched coils to remove an adherent microcatheter from the occipital artery during Onyx embolization of a dural arteriovenous fistula. We used this technique successfully in a 62-year-old man with a posterior fossa dural arteriovenous fistula. An Echelon-10 microcatheter (eV3 Neurovascular, Inc.) system became adherent in the right occipital artery because of reflux and vessel tortuosity. Significant stretching of the microcatheter was observed during attempted removal. A 2-mm Amplatz Goose Neck microsnare (Microvena Corp., White Bear Lake, MN) was placed through a Rapid Transit microcatheter (Cordis Corp., Miami, FL). The hub of the indwelling Echelon microcatheter was cut off and the snare advanced over the outside of the microcatheter. The snare and Rapid Transit microcatheter were then advanced into the guiding catheter (6-French) as a unit over the indwelling Echelon microcatheter. Using the adherent Echelon as a "monorail" guide, the snare and Rapid Transit microcatheter were advanced distally into the occipital artery and the snare was retracted to engage the microcatheter. The microcatheters and snare were then easily removed because of the second vector of force placed by the snare system on the adherent microcatheter very close to the point of adherence. The monorail snare technique represents a simple and safe way to remove an adherent microcatheter from an Onyx cast during the embolization of dural arteriovenous fistulas. Prospective knowledge of this technique will facilitate more aggressive embolization without the reservation that a retained microcatheter could require surgical removal or anticoagulation.
Wet air oxidation and catalytic wet air oxidation for dyes degradation.
Ovejero, Gabriel; Sotelo, José Luis; Rodríguez, Araceli; Vallet, Ana; García, Juan
2011-11-01
Textile industry produces wastewater which contributes to water pollution since it utilizes a lot of chemicals. Preliminary studies show that the wastewater from textile industries contains grease, wax, surfactant, and dyes. The objective of this study was to determine the treatment efficiency of the nickel catalysts supported on hydrotalcites in three-dye model compounds and two types of wastewater. Hydrotalcites were employed to prepare supported nickel catalysts by wetness impregnation technique. Metal loadings from 1 to 10 wt% were tested. Catalysts were characterized by several techniques. They were tested in a catalytic wet air oxidation of three dyes and two wastewaters with different origins. It could be observed that the higher the metal content, the lower the BET area, possibly due to sintering of Ni and the consequent blocking of the pores by the metal. In addition, metallic dispersion was also higher when the metal content was lower. Dye conversion was more than 95% for every catalyst showing no differences with the nickel content. A high degree of dye conversion was achieved. Wet air oxidation (WAO) and catalytic wet air oxidation (CWAO) processes have been proved to be extremely efficient in TOC removal for wastewaters. The CWAO process can be used to remove dyes from wastewater. Three different dyes were tested showing satisfactory results in all of them. TOC degradation and dye removal in the presence of the catalyst were effective. Also, the HTNi catalyst is very active for organic matter and toxicity removal in wastewaters.
Methods for artifact detection and removal from scalp EEG: A review.
Islam, Md Kafiul; Rastegarnia, Amir; Yang, Zhi
2016-11-01
Electroencephalography (EEG) is the most popular brain activity recording technique used in wide range of applications. One of the commonly faced problems in EEG recordings is the presence of artifacts that come from sources other than brain and contaminate the acquired signals significantly. Therefore, much research over the past 15 years has focused on identifying ways for handling such artifacts in the preprocessing stage. However, this is still an active area of research as no single existing artifact detection/removal method is complete or universal. This article presents an extensive review of the existing state-of-the-art artifact detection and removal methods from scalp EEG for all potential EEG-based applications and analyses the pros and cons of each method. First, a general overview of the different artifact types that are found in scalp EEG and their effect on particular applications are presented. In addition, the methods are compared based on their ability to remove certain types of artifacts and their suitability in relevant applications (only functional comparison is provided not performance evaluation of methods). Finally, the future direction and expected challenges of current research is discussed. Therefore, this review is expected to be helpful for interested researchers who will develop and/or apply artifact handling algorithm/technique in future for their applications as well as for those willing to improve the existing algorithms or propose a new solution in this particular area of research. Copyright © 2016 Elsevier Masson SAS. All rights reserved.
Biological phosphorus removal in wastewater treatment.
Timmerman, M W
1984-09-01
Several commercially available systems claim to remove phosphate biologically from municipal wastewater. Techniques such as scanning electron microscopy, transmission electron microscopy and 31P nuclear magnetic resonance (NMR) have demonstrated that the phosphate removed is stored within bacterial cells as polyphosphate. Acinetobacter species are usually isolated from phosphate-removing systems although there is a great deal of evidence which casts doubt on the exclusive role of these organisms.
Pourabadehei, Mehdi; Mulligan, Catherine N
2016-06-01
Harbour areas play important roles in the economy worldwide. Human activities, however, in those areas, generate contamination, which mostly accumulates in sediments. On the other hand, harbour areas have been facing deposition of significant amounts of sediment each year. As a consequence, shallowness and accumulation of contaminants in sediment become challenging issues in harbours. Among the various management options for remediation of contaminated sediments in harbours, resuspension technique was introduced as a new approach to address those issues. The concept of the resuspension method is that finer sediments have a greater tendency to adsorb the contamination. Therefore, removing the finer sediments instead of dredging the whole contaminated area is the main goal of the resuspension technique. The objective of this paper was to evaluate the effect of the resuspension method on reducing the concentration of contamination and distribution of heavy metals in sediment and suspended particulate matter. The resuspension method was successful in reducing the concentration of seven selected heavy metals (Cr, Ni, Cu, Zn, As, Cd and Pb) by removing just 4% of the contaminated sediment. The contamination intensity in the sediment, presented by geoaccumulation index, was reduced for Cd and Pb as the main contaminants by 26 and 28 percent and the rest of the selected heavy metals returned to the natural level. The results of the sequential extraction tests and enrichment factor implied that the resuspension technique is capable of decreasing the risk of remobilization of heavy metals in the aquatic ecosystem. Copyright © 2016 Elsevier Ltd. All rights reserved.
Choi, Hyun Ho; Lee, Ju Hwan; Kim, Sung Min; Park, Sung Yun
2015-01-01
Here, the speckle noise in ultrasonic images is removed using an image fusion-based denoising method. To optimize the denoising performance, each discrete wavelet transform (DWT) and filtering technique was analyzed and compared. In addition, the performances were compared in order to derive the optimal input conditions. To evaluate the speckle noise removal performance, an image fusion algorithm was applied to the ultrasound images, and comparatively analyzed with the original image without the algorithm. As a result, applying DWT and filtering techniques caused information loss and noise characteristics, and did not represent the most significant noise reduction performance. Conversely, an image fusion method applying SRAD-original conditions preserved the key information in the original image, and the speckle noise was removed. Based on such characteristics, the input conditions of SRAD-original had the best denoising performance with the ultrasound images. From this study, the best denoising technique proposed based on the results was confirmed to have a high potential for clinical application.
Mannan, Malik M Naeem; Jeong, Myung Y; Kamran, Muhammad A
2016-01-01
Electroencephalography (EEG) is a portable brain-imaging technique with the advantage of high-temporal resolution that can be used to record electrical activity of the brain. However, it is difficult to analyze EEG signals due to the contamination of ocular artifacts, and which potentially results in misleading conclusions. Also, it is a proven fact that the contamination of ocular artifacts cause to reduce the classification accuracy of a brain-computer interface (BCI). It is therefore very important to remove/reduce these artifacts before the analysis of EEG signals for applications like BCI. In this paper, a hybrid framework that combines independent component analysis (ICA), regression and high-order statistics has been proposed to identify and eliminate artifactual activities from EEG data. We used simulated, experimental and standard EEG signals to evaluate and analyze the effectiveness of the proposed method. Results demonstrate that the proposed method can effectively remove ocular artifacts as well as it can preserve the neuronal signals present in EEG data. A comparison with four methods from literature namely ICA, regression analysis, wavelet-ICA (wICA), and regression-ICA (REGICA) confirms the significantly enhanced performance and effectiveness of the proposed method for removal of ocular activities from EEG, in terms of lower mean square error and mean absolute error values and higher mutual information between reconstructed and original EEG.
Mannan, Malik M. Naeem; Jeong, Myung Y.; Kamran, Muhammad A.
2016-01-01
Electroencephalography (EEG) is a portable brain-imaging technique with the advantage of high-temporal resolution that can be used to record electrical activity of the brain. However, it is difficult to analyze EEG signals due to the contamination of ocular artifacts, and which potentially results in misleading conclusions. Also, it is a proven fact that the contamination of ocular artifacts cause to reduce the classification accuracy of a brain-computer interface (BCI). It is therefore very important to remove/reduce these artifacts before the analysis of EEG signals for applications like BCI. In this paper, a hybrid framework that combines independent component analysis (ICA), regression and high-order statistics has been proposed to identify and eliminate artifactual activities from EEG data. We used simulated, experimental and standard EEG signals to evaluate and analyze the effectiveness of the proposed method. Results demonstrate that the proposed method can effectively remove ocular artifacts as well as it can preserve the neuronal signals present in EEG data. A comparison with four methods from literature namely ICA, regression analysis, wavelet-ICA (wICA), and regression-ICA (REGICA) confirms the significantly enhanced performance and effectiveness of the proposed method for removal of ocular activities from EEG, in terms of lower mean square error and mean absolute error values and higher mutual information between reconstructed and original EEG. PMID:27199714
Kuçi, Astrit; Alaçam, Tayfun; Yavaş, Ozer; Ergul-Ulger, Zeynep; Kayaoglu, Guven
2014-10-01
The aim of this study was to test the dentinal tubule penetration of AH26 (Dentsply DeTrey, Konstanz, Germany) and MTA Fillapex (Angelus, Londrina, PR, Brazil) in instrumented root canals obturated by using cold lateral compaction or warm vertical compaction techniques in either the presence or absence of the smear layer. Forty-five extracted single-rooted human mandibular premolar teeth were used. The crowns were removed, and the root canals were instrumented by using the Self-Adjusting File (ReDent-Nova, Ra'anana, Israel) with continuous sodium hypochlorite (2.6%) irrigation. Final irrigation was either with 5% EDTA or with sodium hypochlorite. The canals were dried and obturated by using rhodamine B-labeled AH26 or MTA Fillapex in combination with the cold lateral compaction or the warm vertical compaction technique. After setting, the roots were sectioned horizontally at 4-, 8-, and 12-mm distances from the apical tip. On each section, sealer penetration in the dentinal tubules was measured by using confocal laser scanning microscopy. Regardless of the usage of EDTA, MTA Fillapex, compared with AH26, was associated with greater sealer penetration when used with the cold lateral compaction technique, and, conversely, AH26, compared with MTA Fillapex, was associated with greater sealer penetration when used with the warm vertical compaction technique (P < .05). Removal of the smear layer increased the penetration depth of MTA Fillapex used with the cold lateral compaction technique (P < .05); however, it had no significant effect on the penetration depth of AH26. Greater sealer penetration could be achieved with either the MTA Fillapex-cold lateral compaction combination or with the AH26-warm vertical compaction combination. Smear layer removal was critical for the penetration of MTA Fillapex; however, the same did not hold for AH26. Copyright © 2014 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.
Ates, Hasan; Dizge, Nadir; Yatmaz, H Cengiz
2017-01-01
In this study, an electrocoagulation reactor (ECR) and photocatalytic reactor (PCR) were tested to understand the performance of combined electrocoagulation and photocatalytic-degradation of olive washing wastewater (OWW). The effects of initial pH (6.0, 6.9, 8.0, 9.0), applied voltage (10.0, 12.5, 15.0 V), and operating time (30, 60, 90, 120 min) were investigated in the electrocoagulation reactor when aluminum electrodes were used as both anode and cathode. The pH, conductivity, color, chemical oxygen demand (COD), and phenol were measured versus time to determine the efficiency of the ECR and PCR process. It was observed that electrocoagulation as a single treatment process supplied the COD removal of 62.5%, color removal of 98.1%, and total phenol removal of 87% at optimum conditions as pH 6.9, applied voltage of 12.5 V, and operating time of 120 min. Moreover, final pH and conductivity were 7.7 and 980 μS/cm, respectively. On the other hand, the effect of semiconductor catalyst type (TiO 2 and ZnO) and loading (1, 2, 3 g/L) were tested using PCR as a stand-alone technique. It was found that photocatalytic degradation as a single treatment process when using 1 g/L ZnO achieved the COD removal of 46%, color removal of 99% with a total phenol removal of 41% at optimum conditions. Final pH and conductivity were 6.2 and 915 μS/cm, respectively. Among semiconductor catalysts, TiO 2 and ZnO performed identical efficiencies for both COD and total phenol removal. Moreover, combination in which electrochemical degradation was employed as a pre-treatment to the photocatalytic degradation process obtained high COD removal of 88% and total phenol, as well as color removal of 100% for the OWW. The electrochemical treatment alone was not effective, but in combination with the photocatalytic process, led to a high-quality effluent. Finally, sludge collected from the electrocoagulation process was characterized by attenuated total reflection Fourier transform infrared and X-ray powder diffraction analyses.
Endotoxin hitchhiking on polymer nanoparticles
NASA Astrophysics Data System (ADS)
Donnell, Mason L.; Lyon, Andrew J.; Mormile, Melanie R.; Barua, Sutapa
2016-07-01
The control of microbial infections is critical for the preparation of biological media including water to prevent lethal septic shock. Sepsis is one of the leading causes of death in the United States. More than half a million patients suffer from sepsis every year. Both gram-positive and gram-negative bacteria are responsible for septic infection by the most common organisms i.e., Escherichia coli and Pseuodomonas aeruginosa. The bacterial cell membrane releases negatively charged endotoxins upon death and enzymatic destruction, which stimulate antigenic response in humans to gram-negative infections. Several methods including distillation, ethylene oxide treatment, filtration and irradiation have been employed to remove endotoxins from contaminated samples, however, the reduction efficiency remains low, and presents a challenge. Polymer nanoparticles can be used to overcome the current inability to effectively sequester endotoxins from water. This process is termed endotoxin hitchhiking. The binding of endotoxin on polymer nanoparticles via electrostatic and hydrophobic interactions offers efficient removal from water. However, the effect of polymer nanoparticles and its surface areas has not been investigated for removal of endotoxins. Poly(ε-caprolactone) (PCL) polymer was tested for its ability to effectively bind and remove endotoxins from water. By employing a simple one-step phase separation technique, we were able to synthesize PCL nanoparticles of 398.3 ± 95.13 nm size and a polydispersity index of 0.2. PCL nanoparticles showed ∼78.8% endotoxin removal efficiency, the equivalent of 3.9 × 105 endotoxin units (EU) per ml. This is 8.34-fold more effective than that reported for commercially available membranes. Transmission electron microscopic images confirmed binding of multiple endotoxins to the nanoparticle surface. The concept of using nanoparticles may be applicable not only to eliminate gram-negative bacteria, but also for any gram-positive bacteria, fungi and parasites.
Terbuthylazine and desethylterbuthylazine: Recent occurrence, mobility and removal techniques.
Tasca, Andrea Luca; Puccini, Monica; Fletcher, Ashleigh
2018-07-01
The herbicide terbuthylazine (TBA) has displaced atrazine in most of EU countries, becoming one of the most regularly used pesticides and, therefore, frequently detected in natural waters. The affinity of TBA for soil organic matter suggests prolonged contamination; degradation leads to the release of the metabolite desethylterbuthylazine (DET), which has higher water solubility and binds more weakly to organic matter compared to the parent compound, resulting in higher associated risk for contamination of groundwater resources. Additionally, TBA and DET are chemicals of emerging concern because of their persistence and toxicity towards aquatic organisms; moreover, they are known to have significant endocrine disruption capacity to wildlife and humans. Conventional treatments applied during drinking water production do not lead to the complete removal of these chemicals; activated carbon provides the greatest efficiency, whereas ozonation can generate by-products with comparable oestrogenic activity to atrazine. Hydrogen peroxide alone is ineffective to degrade TBA, while UV/H 2 O 2 advanced oxidation and photocatalysis are the most effective processes for oxidation of TBA. It has been determined that direct photolysis gives the highest degradation efficiency of all UV/H 2 O 2 treatments, while most of the photocatalytic degradation is attributed to OH radicals, and TiO 2 solar-photocatalytic ozonation can lead to almost complete TBA removal in ∼30 min. Constructed wetlands provide a valuable buffer capacity, protecting downstream surface waters from contaminated runoff. TBA and DET occurrence are summarized and removal techniques are critically evaluated and compared, to provide the reader with a comprehensive guide to state-of-the-art TBA removal and potential future treatments. Copyright © 2018 Elsevier Ltd. All rights reserved.
A titration model for evaluating calcium hydroxide removal techniques.
Phillips, Mark; McClanahan, Scott; Bowles, Walter
2015-01-01
Calcium hydroxide (Ca(OH)2) has been used in endodontics as an intracanal medicament due to its antimicrobial effects and its ability to inactivate bacterial endotoxin. The inability to totally remove this intracanal medicament from the root canal system, however, may interfere with the setting of eugenol-based sealers or inhibit bonding of resin to dentin, thus presenting clinical challenges with endodontic treatment. This study used a chemical titration method to measure residual Ca(OH)2 left after different endodontic irrigation methods. Eighty-six human canine roots were prepared for obturation. Thirty teeth were filled with known but different amounts of Ca(OH)2 for 7 days, which were dissolved out and titrated to quantitate the residual Ca(OH)2 recovered from each root to produce a standard curve. Forty-eight of the remaining teeth were filled with equal amounts of Ca(OH)2 followed by gross Ca(OH)2 removal using hand files and randomized treatment of either: 1) Syringe irrigation; 2) Syringe irrigation with use of an apical file; 3) Syringe irrigation with added 30 s of passive ultrasonic irrigation (PUI), or 4) Syringe irrigation with apical file and PUI (n=12/group). Residual Ca(OH)2 was dissolved with glycerin and titrated to measure residual Ca(OH)2 left in the root. No method completely removed all residual Ca(OH)2. The addition of 30 s PUI with or without apical file use removed Ca(OH)2 significantly better than irrigation alone. This technique allowed quantification of residual Ca(OH)2. The use of PUI (with or without apical file) resulted in significantly lower Ca(OH)2 residue compared to irrigation alone.
Yu, Kuo-Pin; Lee, Grace Whei-May; Huang, Wei-Ming; Wu, Chih-Cheng; Lou, Chia-ling; Yang, Shinhao
2006-05-01
Nowadays, the heating, ventilation, and air conditioning (HVAC) system has been an important facility for maintaining indoor air quality. However, the primary function of typical HVAC systems is to control the temperature and humidity of the supply air. Most indoor air pollutants, such as volatile organic compounds (VOCs), cannot be removed by typical HVAC systems. Thus, some air handling units for removing VOCs should be added in typical HVAC systems. Among all of the air cleaning techniques used to remove indoor VOCs, photocatalytic oxidation is an attractive alternative technique for indoor air purification and deodorization. The objective of this research is to investigate the VOC removal efficiency of the photocatalytic filter in a HVAC system. Toluene and formaldehyde were chosen as the target pollutants. The experiments were conducted in a stainless steel chamber equipped with a simplified HVAC system. A mechanical filter coated with Degussa P25 titania photocatalyst and two commercial photocatalytic filters were used as the photocatalytic filters in this simplified HVAC system. The total air change rates were controlled at 0.5, 0.75, 1, 1.25, and 1.5 hr(-1), and the relative humidity (RH) was controlled at 30%, 50%, and 70%. The ultraviolet lamp used was a 4-W, ultraviolet-C (central wavelength at 254 nm) strip light bulb. The first-order decay constant of toluene and formaldehyde found in this study ranged from 0.381 to 1.01 hr(-1) under different total air change rates, from 0.34 to 0.433 hr(-1) under different RH, and from 0.381 to 0.433 hr(-1) for different photocatalytic filters.
Brandmeir, Nicholas; Sather, Michael
2018-02-20
One of the most effective treatments for epilepsy is resection, but it remains underutilized. Efforts must be made to increase the ease, safety, and efficacy of epilepsy resection to improve utilization. Studies have shown an improved risk profile of stereoelectroencephalography (SEEG) over subdural grids (SDG) for invasive monitoring. One limitation to increased adoption of SEEG at epilepsy centers is the theoretical difficulty of planning a delayed resection once electrodes are removed. Our objective was to develop and present a technique using readily available neuronavigation technology to guide a cortical, non-lesional epilepsy resection with co-registration of imaging during invasive monitoring to imaging in an explanted patient, allowing for virtual visualization of electrodes. An example case taking advantage of the technique described above as an adjunct for an anatomically guided resection is presented with technical details and images. Intraoperative neuronavigation was successfully used to virtually represent previously removed SEEG electrodes and accuracy could be easily verified by examining scars on the scalp, bone, dura and pia. The simple technique presented can be a useful adjunct to resection following SEEG. This may help increase the adoption of SEEG, even when resection is planned.
Shokry, Mohamed; Aboelsaad, Nayer
2016-01-01
The purpose of this study was to test the effect of the surgical removal of impacted mandibular third molars using piezosurgery versus the conventional surgical technique on postoperative sequelae and bone healing. Material and Methods. This study was carried out as a randomized controlled clinical trial: split mouth design. Twenty patients with bilateral mandibular third molar mesioangular impaction class II position B indicated for surgical extraction were treated randomly using either the piezosurgery or the conventional bur technique on each site. Duration of the procedure, postoperative edema, trismus, pain, healing, and bone density and quantity were evaluated up to 6 months postoperatively. Results. Test and control sites were compared using paired t-test. There was statistical significance in reduction of pain and swelling in test sites, where the time of the procedure was statistically increased in test site. For bone quantity and quality, statistical difference was found where test site showed better results. Conclusion. Piezosurgery technique improves quality of patient's life in form of decrease of postoperative pain, trismus, and swelling. Furthermore, it enhances bone quality within the extraction socket and bone quantity along the distal aspect of the mandibular second molar. PMID:27597866
Enhanced removal of nitrate from water using surface modification of adsorbents--a review.
Loganathan, Paripurnanda; Vigneswaran, Saravanamuthu; Kandasamy, Jaya
2013-12-15
Elevated concentration of nitrate results in eutrophication of natural water bodies affecting the aquatic environment and reduces the quality of drinking water. This in turn causes harm to people's health, especially that of infants and livestock. Adsorbents with the high capacity to selectively adsorb nitrate are required to effectively remove nitrate from water. Surface modifications of adsorbents have been reported to enhance their adsorption of nitrate. The major techniques of surface modification are: protonation, impregnation of metals and metal oxides, grafting of amine groups, organic compounds including surfactant coating of aluminosilicate minerals, and heat treatment. This paper reviews current information on these techniques, compares the enhanced nitrate adsorption capacities achieved by the modifications, and the mechanisms of adsorption, and presents advantages and drawbacks of the techniques. Most studies on this subject have been conducted in batch experiments. These studies need to include continuous mode column trials which have more relevance to real operating systems and pilot-plant trials. Reusability of adsorbents is important for economic reasons and practical treatment applications. However, only limited information is available on the regeneration of surface modified adsorbents. Copyright © 2013 Elsevier Ltd. All rights reserved.
Effect of soil compaction and biomass removal on soil CO2 efflux in a Missouri forest
Felix, Jr. Ponder
2005-01-01
Forest disturbances associated with harvesting activities can affect soil properties and soil respiration. A soda-lime technique was used to measure soil carbon dioxide (CO2) efflux rates in clearcut plots of a Missouri oak-hickory (Quercus spp. L.-Carya spp. Nutt.) forest 4 years after being treated with two levels of forest...
Impact of postfire management on forest regeneration in a managed hemiboreal forest, Estonia
Kristi Parro; Marek Metslaid; Getter Renel; Allan Sims; John Stanturf; Kalev Jogiste; Kajar Koster
2015-01-01
Fire is a significant agent for the development of boreal and hemiboreal forests, altering soil and light conditions, affecting seedbanks, and removing seed trees. Burned areas should be managed with care, as inappropriate techniques prolong the regeneration period and reduce the diversity and resilience of stands to disturbances. To study the effects of fire and...
A study of emergency American football helmet removal techniques.
Swartz, Erik E; Mihalik, Jason P; Decoster, Laura C; Hernandez, Adam E
2012-09-01
The purpose was to compare head kinematics between the Eject Helmet Removal System and manual football helmet removal. This quasi-experimental study was conducted in a controlled laboratory setting. Thirty-two certified athletic trainers (sex, 19 male and 13 female; age, 33 ± 10 years; height, 175 ± 12 cm; mass, 86 ± 20 kg) removed a football helmet from a healthy model under 2 conditions: manual helmet removal and Eject system helmet removal. A 6-camera motion capture system recorded 3-dimensional head position. Our outcome measures consisted of the average angular velocity and acceleration of the head in each movement plane (sagittal, frontal, and transverse), the resultant angular velocity and acceleration, and total motion. Paired-samples t tests compared each variable across the 2 techniques. Manual helmet removal elicited greater average angular velocity in the sagittal and transverse planes and greater resultant angular velocity compared with the Eject system. No differences were observed in average angular acceleration in any single plane of movement; however, the resultant angular acceleration was greater during manual helmet removal. The Eject Helmet Removal System induced greater total head motion. Although the Eject system created more motion at the head, removing a helmet manually resulted in more sudden perturbations as identified by resultant velocity and acceleration of the head. The implications of these findings relate to the care of all cervical spine-injured patients in emergency medical settings, particularly in scenarios where helmet removal is necessary. Copyright © 2012 Elsevier Inc. All rights reserved.
Zhou, Xiang-Xiang; Zhang, Li-Quan; Yuan, Lian-Qi
2008-02-01
By using biological slope-protection techniques, oxidation pond system, and zeolite treatment system, a demonstration project of ecological restoration of ditches at the Qianwei Village of Chongming County in Shanghai was implemented, and an evaluation on the project was made via a runoff simulation experiment and the measurements of the parameters soil shear strength, biodiversity, and ditch water quality. The results showed that covering the dich slopes with shrub could significantly increase soil shear strength, compactness and moisture content, and the formed vegetation had significant effects on retarding runoff and removing TSS (P < 0.05). Applying live fascines could significantly increase soil shear strength and TSS removal rate (P < 0.05), but its effects on increasing soil compactness and moisture content and retaining runoff were not significant. After the implement of the demonstration project, the total N and P concentrations in ditch water decreased significantly, habitat quality and aesthetic value of ditch slope improved, and biodiversity enhanced greatly. The integration of the biological techniques with other ecological restoration measures could stabilize ditch slope, improve ditch habitat quality, and restore the ecological environment of the ditches.
Mantini, D; Franciotti, R; Romani, G L; Pizzella, V
2008-03-01
The major limitation for the acquisition of high-quality magnetoencephalography (MEG) recordings is the presence of disturbances of physiological and technical origins: eye movements, cardiac signals, muscular contractions, and environmental noise are serious problems for MEG signal analysis. In the last years, multi-channel MEG systems have undergone rapid technological developments in terms of noise reduction, and many processing methods have been proposed for artifact rejection. Independent component analysis (ICA) has already shown to be an effective and generally applicable technique for concurrently removing artifacts and noise from the MEG recordings. However, no standardized automated system based on ICA has become available so far, because of the intrinsic difficulty in the reliable categorization of the source signals obtained with this technique. In this work, approximate entropy (ApEn), a measure of data regularity, is successfully used for the classification of the signals produced by ICA, allowing for an automated artifact rejection. The proposed method has been tested using MEG data sets collected during somatosensory, auditory and visual stimulation. It was demonstrated to be effective in attenuating both biological artifacts and environmental noise, in order to reconstruct clear signals that can be used for improving brain source localizations.
Safety and efficacy of photobiomodulation therapy for weight loss: a review
NASA Astrophysics Data System (ADS)
Ahmed, Ambereen
2018-02-01
Photobiomodulation therapy uses light from a laser and is, therefore, a non-invasive, non-thermal treatment that is effective in reducing chronic pain and inflammation, stimulating wound healing and tissue regeneration. Due to its accessibility and ease of use, it is also being explored as an alternative to lipoplasty for fat removal. This review covers literature focusing on the applications of photobiomodulation therapy, with particular emphasis on the safety and efficacy of this therapy on fat loss. Based on the studies reported, photobiomodulation therapy is a safe technique that showed promising results in reducing the circumference of treated body parts. Also, photobiomodulation therapy is particularly effective when used in combination with exercise and physical therapy. The mechanism of action of how photobiomodulation therapy removes fat from the cells is controversial and requires further investigation. Very little scientific indication endures in support of the claims that infrared light, whether dispensed by laser, lamp, or while in a body wrap, can assist people to lose extra weight or shape their physique. Moreover, additional studies demonstrating the efficacy of photo modulation therapy in larger groups would be helpful in establishing this technique for regular clinical use.
Effects on Diagnostic Parameters After Removing Additional Synchronous Gear Meshes
NASA Technical Reports Server (NTRS)
Decker, Harry J.
2003-01-01
Gear cracks are typically difficult to diagnose with sufficient time before catastrophic damage occurs. Significant damage must be present before algorithms appear to be able to detect the damage. Frequently there are multiple gear meshes on a single shaft. Since they are all synchronous with the shaft frequency, the commonly used synchronous averaging technique is ineffective in removing other gear mesh effects. Carefully applying a filter to these extraneous gear mesh frequencies can reduce the overall vibration signal and increase the accuracy of commonly used vibration metrics. The vibration signals from three seeded fault tests were analyzed using this filtering procedure. Both the filtered and unfiltered vibration signals were then analyzed using commonly used fault detection metrics and compared. The tests were conducted on aerospace quality spur gears in a test rig. The tests were conducted at speeds ranging from 2500 to 5000 revolutions per minute and torques from 184 to 228 percent of design load. The inability to detect these cracks with high confidence results from the high loading which is causing fast fracture as opposed to stable crack growth. The results indicate that these techniques do not currently produce an indication of damage that significantly exceeds experimental scatter.
Removal of 4-Nitrophenol from Water Using Ag–N–P-Tridoped TiO2 by Photocatalytic Oxidation Technique
Achamo, Temesgen; Yadav, O. P.
2016-01-01
Photocatalytic oxidation using semiconductor nanoparticles is an efficient, eco-friendly, and cost-effective process for the removal of organic pollutants, such as dyes, pesticides, phenols, and their derivatives in water. In the present study, nanosize Ag–N–P-tridoped titanium(IV) oxide (TiO2) was prepared by using sol–gel-synthesized Ag-doped TiO2 and soybean (Glycine max) or chickpea (Cicer arietinum) seeds as nonmetallic bioprecursors. As-synthesized photocatalysts were characterized using X-ray diffraction, Fourier transform infrared, and ultra violet (UV)–visible spectroscopic techniques. Average crystallite size of the studied photocatalysts was within 39–46 nm. Whereas doped Ag in TiO2 minimized the photogenerated electron–hole recombination, doped N and P extended its photoabsorption edge to visible region. Tridoping of Ag, N, and P in TiO2 exhibited synergetic effect toward enhancing its photocatalytic degradation of 4-nitrophenol (4-NP), separately, under UV and visible irradiations. At three hours, degradations of 4-NP over Ag–N–P-tridoped TiO2 under UV and visible radiations were 73.8 and 98.1%, respectively. PMID:27081309
Neuro-endoscopic management of intraventricular neurocysticercosis (NCC).
Husain, M; Jha, D K; Rastogi, M; Husain, N; Gupta, R K
2007-01-01
Various approaches including endoscopy have been used for the treatment of intraventricular and cisternal NCC. We present our technique of Neuro-endoscopic management of intraventricular NCC. Twenty-one cases, 13 females and 8 males (age range 12-50 years; mean, 25.7 years), of intraventricular NCC [lateral (n = 6), third (n = 6), fourth (n = 10) ventricles including a patient with both lateral and third ventricular cysts] producing obstructive hydrocephalus formed the group of study. Gaab Universal Endoscope System along with 4 mm 0 degrees and 30 degrees rigid telescopes were used through a frontal burr-hole for removal of intraventricular including intra-fourth ventricular (n = 10) NCC. Endoscopic third ventriculostomy (ETV) was done for internal cerebrospinal fluid (CSF) diversion. Average follow up was 18 months. Complete (n = 18) or partial (n = 2) removal of NCC was done in 20 patients, while a cyst located at foramen of Monro slipped and migrated to occipital or temporal horn in 1 patient. Thirty-degree 4-mm rigid telescope provided excellent image quality with ability to address even intra-fourth ventricular NCC through the dilated aqueduct using a curved tip catheter. No patient required further surgery for their hydrocephalus. There was no operative complication and post-operative ventriculitis was not seen in any case despite partial removal of NCC. Neuro-endoscopic surgery is an effective treatment modality for patients with intraventricular NCC. It effectively restores CSF flow and is capable of removing cysts completely or partially from accessible locations causing mass effect. Partial removal or rupture of the cyst does not affect the clinical outcome of the patients.
Keum, Eun-Cheol
2013-01-01
PURPOSE This study evaluated the effectiveness of various methods for removing provisional cement from implant abutments, and what effect these methods have on the retention of prosthesis during the definitive cementation. MATERIALS AND METHODS Forty implant fixture analogues and abutments were embedded in resin blocks. Forty cast crowns were fabricated and divided into 4 groups each containing 10 implants. Group A was cemented directly with the definitive cement (Cem-Implant). The remainder were cemented with provisional cement (Temp-Bond NE), and classified according to the method for cleaning the abutments. Group B used a plastic curette and wet gauze, Group C used a rubber cup and pumice, and Group D used an airborne particle abrasion technique. The abutments were observed using a stereomicroscope after removing the provisional cement. The tensile bond strength was measured after the definitive cementation. Statistical analysis was performed using one-way analysis of variance test (α=.05). RESULTS Group B clearly showed provisional cement remaining, whereas the other groups showed almost no cement. Groups A and B showed a relatively smooth surface. More roughness was observed in Group C, and apparent roughness was noted in Group D. The tensile bond strength tests revealed Group D to have significantly the highest tensile bond strength followed in order by Groups C, A and B. CONCLUSION A plastic curette and wet gauze alone cannot effectively remove the residual provisional cement on the abutment. The definitive retention increased when the abutments were treated with rubber cup/pumice or airborne particle abraded to remove the provisional cement. PMID:24049563
The electrical properties of 60 keV zinc ions implanted into semi-insulating gallium arsenide
NASA Technical Reports Server (NTRS)
Littlejohn, M. A.; Anikara, R.
1972-01-01
The electrical behavior of zinc ions implanted into chromium-doped semiinsulating gallium arsenide was investigated by measurements of the sheet resistivity and Hall effect. Room temperature implantations were performed using fluence values from 10 to the 12th to 10 to the 15th power/sq cm at 60 keV. The samples were annealed for 30 minutes in a nitrogen atmosphere up to 800 C in steps of 200 C and the effect of this annealing on the Hall effect and sheet resistivity was studied at room temperature using the Van der Pauw technique. The temperature dependence of sheet resistivity and mobility was measured from liquid nitrogen temperature to room temperature. Finally, a measurement of the implanted profile was obtained using a layer removal technique combined with the Hall effect and sheet resistivity measurements.
Tor, Ali; Aydin, Mehmet Emin; Aydin, Senar; Tabakci, Mustafa; Beduk, Fatma
2013-11-15
An aminopropyl silica gel-immobilized calix[6]arene (C[6]APS) has been used for the removal of lindane from an aqueous solution in batch sorption technique. The C[6]APS was synthesized with p-tert-butylcalix[6]arene hexacarboxylate derivative and aminopropyl silica gel in the presence of N,N'-diisopropyl carbodiimide coupling reagent. The sorption study was carried out as functions of solution pH, contact time, initial lindane concentration, C[6]APS dosage and ionic strength of solution. The matrix effect of natural water samples on the sorption efficiency of C[6]APS was also investigated. Maximum lindane removal was obtained at a wide pH range of 2-8 and sorption equilibrium was achieved in 2h. The isotherm analysis indicated that the sorption data can be represented by both Langmuir and Freundlich isotherm models. Increasing ionic strength of the solutions increased the sorption efficiency and matrix of natural water samples had no effect on the sorption of lindane. By using multilinear regression model, regression equation was also developed to explain the effects of the experimental variables. Copyright © 2013 Elsevier B.V. All rights reserved.
Viswanathan, N B; Thomas, P A; Pandit, J K; Kulkarni, M G; Mashelkar, R A
1999-03-08
Emulsification-solvent removal methods have been widely used for encapsulating bioactive macromolecules like proteins and polypeptides in biodegradable polymers. We report, a (water-in-oil)-in-oil emulsion technique wherein proteins and polypeptides differing in molecular weight and shape were encapsulated in polymers of current biomedical interest. When an oil was used as the processing medium in combination with a carefully selected mixed solvent system such that a stable (w/o1/o2 emulsion is formed and solvents are removed by a combination of extraction and evaporation, the entrapment efficiency was high and the product nonporous. The entrapment efficiency of globular proteins exceeded 90% while that of fibrous proteins was around 70%. Fracture studies revealed that the polymer matrix was dense. The mechanism of entrapment involved solvent-induced precipitation of the protein as the microspheres were being formed. The principle of the method will find use in preparation of non-porous polymer microparticles with reduced burst effect.
Network analysis of a financial market based on genuine correlation and threshold method
NASA Astrophysics Data System (ADS)
Namaki, A.; Shirazi, A. H.; Raei, R.; Jafari, G. R.
2011-10-01
A financial market is an example of an adaptive complex network consisting of many interacting units. This network reflects market’s behavior. In this paper, we use Random Matrix Theory (RMT) notion for specifying the largest eigenvector of correlation matrix as the market mode of stock network. For a better risk management, we clean the correlation matrix by removing the market mode from data and then construct this matrix based on the residuals. We show that this technique has an important effect on correlation coefficient distribution by applying it for Dow Jones Industrial Average (DJIA). To study the topological structure of a network we apply the removing market mode technique and the threshold method to Tehran Stock Exchange (TSE) as an example. We show that this network follows a power-law model in certain intervals. We also show the behavior of clustering coefficients and component numbers of this network for different thresholds. These outputs are useful for both theoretical and practical purposes such as asset allocation and risk management.
Dias, Amanda Cristina Vieira; Gomes, Frederico Wegenast; Bila, Daniele Maia; Sant'Anna, Geraldo Lippel; Dezotti, Marcia
2015-10-01
The estrogenicity of waters collected from an important hydrological system in Brazil (Paraiba do Sul and Guandu Rivers) was assessed using the yeast estrogen screen (YES) assay. Sampling was performed in rivers and at the outlets of conventional water treatment plants (WTP). The removal of estrogenic activity by ozonation and chlorination after conventional water treatment (clarification and sand filtration) was investigated employing samples of the Guandu River spiked with estrogens and bisphenol A (BPA). The results revealed a preoccupying incidence of estrogenic activity at levels higher than 1ngL(-1) along some points of the rivers. Another matter of concern was the number of samples from WTPs presenting estrogenicity surpassing 1ngL(-1). The oxidation techniques (ozonation and chlorination) were effective for the removal of estrogenic activity and the combination of both techniques led to good results using less amounts of oxidants. Copyright © 2015 Elsevier Inc. All rights reserved.
Liposuction devices: technology update
Shridharani, Sachin M; Broyles, Justin M; Matarasso, Alan
2014-01-01
Since its introduction by Illouz and others over 30 years ago, suction-assisted lipectomy/liposuction/lipoplasty has evolved tremendously and has developed into one of the most popular procedures in aesthetic plastic surgery. Liposuction is an effective procedure employed to treat localized adipose deposits in patients not suffering from generalized obesity. These accumulations of subcutaneous fat often occur in predictable distributions in both men and women. A cannula connected to a suction-generating source allows for small incisions to be strategically placed and large volumes of fat to be removed. This fat removal leads to improved harmonious balance of a patient’s physique and improved body contour. Various surgical techniques are available and have evolved as technology has improved. Current technology for liposuction includes suction-assisted lipectomy, ultrasound-assisted, power-assisted, laser-assisted, and radiofrequency-assisted. The choice of technology and technique often depends on patient characteristics and surgeon preference. The objective of this review is to provide a thorough assessment of current technologies available to plastic surgeons performing liposuction. PMID:25093000