Sample records for effect size measures

  1. Statistical properties of four effect-size measures for mediation models.

    PubMed

    Miočević, Milica; O'Rourke, Holly P; MacKinnon, David P; Brown, Hendricks C

    2018-02-01

    This project examined the performance of classical and Bayesian estimators of four effect size measures for the indirect effect in a single-mediator model and a two-mediator model. Compared to the proportion and ratio mediation effect sizes, standardized mediation effect-size measures were relatively unbiased and efficient in the single-mediator model and the two-mediator model. Percentile and bias-corrected bootstrap interval estimates of ab/s Y , and ab(s X )/s Y in the single-mediator model outperformed interval estimates of the proportion and ratio effect sizes in terms of power, Type I error rate, coverage, imbalance, and interval width. For the two-mediator model, standardized effect-size measures were superior to the proportion and ratio effect-size measures. Furthermore, it was found that Bayesian point and interval summaries of posterior distributions of standardized effect-size measures reduced excessive relative bias for certain parameter combinations. The standardized effect-size measures are the best effect-size measures for quantifying mediated effects.

  2. The other half of the story: effect size analysis in quantitative research.

    PubMed

    Maher, Jessica Middlemis; Markey, Jonathan C; Ebert-May, Diane

    2013-01-01

    Statistical significance testing is the cornerstone of quantitative research, but studies that fail to report measures of effect size are potentially missing a robust part of the analysis. We provide a rationale for why effect size measures should be included in quantitative discipline-based education research. Examples from both biological and educational research demonstrate the utility of effect size for evaluating practical significance. We also provide details about some effect size indices that are paired with common statistical significance tests used in educational research and offer general suggestions for interpreting effect size measures. Finally, we discuss some inherent limitations of effect size measures and provide further recommendations about reporting confidence intervals.

  3. A novel measure of effect size for mediation analysis.

    PubMed

    Lachowicz, Mark J; Preacher, Kristopher J; Kelley, Ken

    2018-06-01

    Mediation analysis has become one of the most popular statistical methods in the social sciences. However, many currently available effect size measures for mediation have limitations that restrict their use to specific mediation models. In this article, we develop a measure of effect size that addresses these limitations. We show how modification of a currently existing effect size measure results in a novel effect size measure with many desirable properties. We also derive an expression for the bias of the sample estimator for the proposed effect size measure and propose an adjusted version of the estimator. We present a Monte Carlo simulation study conducted to examine the finite sampling properties of the adjusted and unadjusted estimators, which shows that the adjusted estimator is effective at recovering the true value it estimates. Finally, we demonstrate the use of the effect size measure with an empirical example. We provide freely available software so that researchers can immediately implement the methods we discuss. Our developments here extend the existing literature on effect sizes and mediation by developing a potentially useful method of communicating the magnitude of mediation. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  4. An Effect Size Measure for Raju's Differential Functioning for Items and Tests

    ERIC Educational Resources Information Center

    Wright, Keith D.; Oshima, T. C.

    2015-01-01

    This study established an effect size measure for differential functioning for items and tests' noncompensatory differential item functioning (NCDIF). The Mantel-Haenszel parameter served as the benchmark for developing NCDIF's effect size measure for reporting moderate and large differential item functioning in test items. The effect size of…

  5. The Comparability of the Standardized Mean Difference Effect Size across Different Measures of the Same Construct: Measurement Considerations

    ERIC Educational Resources Information Center

    Nugent, William R.

    2006-01-01

    One of the most important effect sizes used in meta-analysis is the standardized mean difference (SMD). In this article, the conditions under which SMD effect sizes based on different measures of the same construct are directly comparable are investigated. The results show that SMD effect sizes from different measures of the same construct are…

  6. Do Effect-Size Measures Measure up?: A Brief Assessment

    ERIC Educational Resources Information Center

    Onwuegbuzie, Anthony J.; Levin, Joel R.; Leech, Nancy L.

    2003-01-01

    Because of criticisms leveled at statistical hypothesis testing, some researchers have argued that measures of effect size should replace the significance-testing practice. We contend that although effect-size measures have logical appeal, they are also associated with a number of limitations that may result in problematic interpretations of them…

  7. Effect Size Measures for Differential Item Functioning in a Multidimensional IRT Model

    ERIC Educational Resources Information Center

    Suh, Youngsuk

    2016-01-01

    This study adapted an effect size measure used for studying differential item functioning (DIF) in unidimensional tests and extended the measure to multidimensional tests. Two effect size measures were considered in a multidimensional item response theory model: signed weighted P-difference and unsigned weighted P-difference. The performance of…

  8. Effect Size as the Essential Statistic in Developing Methods for mTBI Diagnosis.

    PubMed

    Gibson, Douglas Brandt

    2015-01-01

    The descriptive statistic known as "effect size" measures the distinguishability of two sets of data. Distingishability is at the core of diagnosis. This article is intended to point out the importance of effect size in the development of effective diagnostics for mild traumatic brain injury and to point out the applicability of the effect size statistic in comparing diagnostic efficiency across the main proposed TBI diagnostic methods: psychological, physiological, biochemical, and radiologic. Comparing diagnostic approaches is difficult because different researcher in different fields have different approaches to measuring efficacy. Converting diverse measures to effect sizes, as is done in meta-analysis, is a relatively easy way to make studies comparable.

  9. Do Between-Culture Differences Really Mean that People Are Different? A Look at Some Measures of Culture Effect Size.

    ERIC Educational Resources Information Center

    Matsumoto, David; Grissom, Robert J.; Dinnel, Dale L.

    2001-01-01

    Recommends four measures of cultural effect size appropriate for cross-cultural research (standardized difference between two sample means, probabilistic superiority effect size measure, Cohen's U1, and point biserial correlation), demonstrating their efficacy on two data sets from previously published studies and arguing for their use in future…

  10. R2 effect-size measures for mediation analysis

    PubMed Central

    Fairchild, Amanda J.; MacKinnon, David P.; Taborga, Marcia P.; Taylor, Aaron B.

    2010-01-01

    R2 effect-size measures are presented to assess variance accounted for in mediation models. The measures offer a means to evaluate both component paths and the overall mediated effect in mediation models. Statistical simulation results indicate acceptable bias across varying parameter and sample-size combinations. The measures are applied to a real-world example using data from a team-based health promotion program to improve the nutrition and exercise habits of firefighters. SAS and SPSS computer code are also provided for researchers to compute the measures in their own data. PMID:19363189

  11. R2 effect-size measures for mediation analysis.

    PubMed

    Fairchild, Amanda J; Mackinnon, David P; Taborga, Marcia P; Taylor, Aaron B

    2009-05-01

    R(2) effect-size measures are presented to assess variance accounted for in mediation models. The measures offer a means to evaluate both component paths and the overall mediated effect in mediation models. Statistical simulation results indicate acceptable bias across varying parameter and sample-size combinations. The measures are applied to a real-world example using data from a team-based health promotion program to improve the nutrition and exercise habits of firefighters. SAS and SPSS computer code are also provided for researchers to compute the measures in their own data.

  12. Time-Indexed Effect Size for P-12 Reading and Math Program Evaluation

    ERIC Educational Resources Information Center

    Lee, Jaekyung; Finn, Jeremy; Liu, Xiaoyan

    2012-01-01

    This study contextualizes an effect-size-like index of educational treatment effects or any group mean differences in academic achievement by referencing time. The new effect size metric can enrich effect size interpretations while serving as a supplement (but not substitute) for conventional standardized effect size measures. Specifically, the…

  13. Measuring Effect Sizes: The Effect of Measurement Error. Working Paper 19

    ERIC Educational Resources Information Center

    Boyd, Donald; Grossman, Pamela; Lankford, Hamilton; Loeb, Susanna; Wyckoff, James

    2008-01-01

    Value-added models in education research allow researchers to explore how a wide variety of policies and measured school inputs affect the academic performance of students. Researchers typically quantify the impacts of such interventions in terms of "effect sizes", i.e., the estimated effect of a one standard deviation change in the…

  14. [A Review on the Use of Effect Size in Nursing Research].

    PubMed

    Kang, Hyuncheol; Yeon, Kyupil; Han, Sang Tae

    2015-10-01

    The purpose of this study was to introduce the main concepts of statistical testing and effect size and to provide researchers in nursing science with guidance on how to calculate the effect size for the statistical analysis methods mainly used in nursing. For t-test, analysis of variance, correlation analysis, regression analysis which are used frequently in nursing research, the generally accepted definitions of the effect size were explained. Some formulae for calculating the effect size are described with several examples in nursing research. Furthermore, the authors present the required minimum sample size for each example utilizing G*Power 3 software that is the most widely used program for calculating sample size. It is noted that statistical significance testing and effect size measurement serve different purposes, and the reliance on only one side may be misleading. Some practical guidelines are recommended for combining statistical significance testing and effect size measure in order to make more balanced decisions in quantitative analyses.

  15. Effect of air gap on apparent temperature of body wearing various sizes of T-shirt

    NASA Astrophysics Data System (ADS)

    Takatera, M.; Uchiyama, E.; Zhu, C.; Kim, KO; Ishizawa, H.

    2017-10-01

    We investigated the effect of air gap on the apparent temperature. Using the developed thermocouple fabric and a thermal manikin, we measured temperature distribution of the measuring garments due to the change of T-shirt sizes. We were able to measure the apparent temperature distribution at points near a body while wearing different sizes of T-shirts. It was observed that the temperature distribution depending on different air gap between clothing and body. The apparent temperature depends on garment size and place. The effect of air gap on apparent temperature of body was experimentally confirmed.

  16. Causality in Statistical Power: Isomorphic Properties of Measurement, Research Design, Effect Size, and Sample Size.

    PubMed

    Heidel, R Eric

    2016-01-01

    Statistical power is the ability to detect a significant effect, given that the effect actually exists in a population. Like most statistical concepts, statistical power tends to induce cognitive dissonance in hepatology researchers. However, planning for statistical power by an a priori sample size calculation is of paramount importance when designing a research study. There are five specific empirical components that make up an a priori sample size calculation: the scale of measurement of the outcome, the research design, the magnitude of the effect size, the variance of the effect size, and the sample size. A framework grounded in the phenomenon of isomorphism, or interdependencies amongst different constructs with similar forms, will be presented to understand the isomorphic effects of decisions made on each of the five aforementioned components of statistical power.

  17. Meta-Analysis of Effect Sizes Reported at Multiple Time Points Using General Linear Mixed Model.

    PubMed

    Musekiwa, Alfred; Manda, Samuel O M; Mwambi, Henry G; Chen, Ding-Geng

    2016-01-01

    Meta-analysis of longitudinal studies combines effect sizes measured at pre-determined time points. The most common approach involves performing separate univariate meta-analyses at individual time points. This simplistic approach ignores dependence between longitudinal effect sizes, which might result in less precise parameter estimates. In this paper, we show how to conduct a meta-analysis of longitudinal effect sizes where we contrast different covariance structures for dependence between effect sizes, both within and between studies. We propose new combinations of covariance structures for the dependence between effect size and utilize a practical example involving meta-analysis of 17 trials comparing postoperative treatments for a type of cancer, where survival is measured at 6, 12, 18 and 24 months post randomization. Although the results from this particular data set show the benefit of accounting for within-study serial correlation between effect sizes, simulations are required to confirm these results.

  18. Appearance-related teasing, body dissatisfaction, and disordered eating: A meta-analysis.

    PubMed

    Menzel, Jessie E; Schaefer, Lauren M; Burke, Natasha L; Mayhew, Laura L; Brannick, Michael T; Thompson, J Kevin

    2010-09-01

    A meta-analysis was conducted to determine the relationship between appearance and weight-based teasing and three outcome measures: body dissatisfaction, restrictive eating, and bulimic behaviors. Four meta-analyses were conducted. Fifty effect sizes (N=10,618) resulted in a moderate effect size of .39 for the relationship between weight teasing and body dissatisfaction; 24 effect sizes (N=7190) resulted in an effect size of .32 for the relationship between appearance teasing and body dissatisfaction; 20 effect sizes (N=4792) resulted in an effect size of .35 for the relationship between weight teasing and dietary restraint; and 22 effect sizes (N=5091) resulted in an effect size of .36 for the relationship between weight teasing and bulimic behaviors. Significant moderators that emerged were teasing measure type, publication type, study type, age group, and gender. The findings offer further support for the inclusion of strategies in body image and eating disorders' prevention and intervention programs that focus on handling negative, appearance-related commentary. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Violation of the Sphericity Assumption and Its Effect on Type-I Error Rates in Repeated Measures ANOVA and Multi-Level Linear Models (MLM).

    PubMed

    Haverkamp, Nicolas; Beauducel, André

    2017-01-01

    We investigated the effects of violations of the sphericity assumption on Type I error rates for different methodical approaches of repeated measures analysis using a simulation approach. In contrast to previous simulation studies on this topic, up to nine measurement occasions were considered. Effects of the level of inter-correlations between measurement occasions on Type I error rates were considered for the first time. Two populations with non-violation of the sphericity assumption, one with uncorrelated measurement occasions and one with moderately correlated measurement occasions, were generated. One population with violation of the sphericity assumption combines uncorrelated with highly correlated measurement occasions. A second population with violation of the sphericity assumption combines moderately correlated and highly correlated measurement occasions. From these four populations without any between-group effect or within-subject effect 5,000 random samples were drawn. Finally, the mean Type I error rates for Multilevel linear models (MLM) with an unstructured covariance matrix (MLM-UN), MLM with compound-symmetry (MLM-CS) and for repeated measures analysis of variance (rANOVA) models (without correction, with Greenhouse-Geisser-correction, and Huynh-Feldt-correction) were computed. To examine the effect of both the sample size and the number of measurement occasions, sample sizes of n = 20, 40, 60, 80, and 100 were considered as well as measurement occasions of m = 3, 6, and 9. With respect to rANOVA, the results plead for a use of rANOVA with Huynh-Feldt-correction, especially when the sphericity assumption is violated, the sample size is rather small and the number of measurement occasions is large. For MLM-UN, the results illustrate a massive progressive bias for small sample sizes ( n = 20) and m = 6 or more measurement occasions. This effect could not be found in previous simulation studies with a smaller number of measurement occasions. The proportionality of bias and number of measurement occasions should be considered when MLM-UN is used. The good news is that this proportionality can be compensated by means of large sample sizes. Accordingly, MLM-UN can be recommended even for small sample sizes for about three measurement occasions and for large sample sizes for about nine measurement occasions.

  20. Experimental determination of the effect of detector size on profile measurements in narrow photon beams.

    PubMed

    Pappas, E; Maris, T G; Papadakis, A; Zacharopoulou, F; Damilakis, J; Papanikolaou, N; Gourtsoyiannis, N

    2006-10-01

    The aim of this work is to investigate experimentally the detector size effect on narrow beam profile measurements. Polymer gel and magnetic resonance imaging dosimetry was used for this purpose. Profile measurements (Pm(s)) of a 5 mm diameter 6 MV stereotactic beam were performed using polymer gels. Eight measurements of the profile of this narrow beam were performed using correspondingly eight different detector sizes. This was achieved using high spatial resolution (0.25 mm) two-dimensional measurements and eight different signal integration volumes A X A X slice thickness, simulating detectors of different size. "A" ranged from 0.25 to 7.5 mm, representing the detector size. The gel-derived profiles exhibited increased penumbra width with increasing detector size, for sizes >0.5 mm. By extrapolating the gel-derived profiles to zero detector size, the true profile (Pt) of the studied beam was derived. The same polymer gel data were also used to simulate a small-volume ion chamber profile measurement of the same beam, in terms of volume averaging. The comparison between these results and actual corresponding small-volume chamber profile measurements performed in this study, reveal that the penumbra broadening caused by both volume averaging and electron transport alterations (present in actual ion chamber profile measurements) is a lot more intense than that resulted by volume averaging effects alone (present in gel-derived profiles simulating ion chamber profile measurements). Therefore, not only the detector size, but also its composition and tissue equivalency is proved to be an important factor for correct narrow beam profile measurements. Additionally, the convolution kernels related to each detector size and to the air ion chamber were calculated using the corresponding profile measurements (Pm(s)), the gel-derived true profile (Pt), and convolution theory. The response kernels of any desired detector can be derived, allowing the elimination of the errors associated with narrow beam profile measurements.

  1. What is the effect of area size when using local area practice style as an instrument?

    PubMed

    Brooks, John M; Tang, Yuexin; Chapman, Cole G; Cook, Elizabeth A; Chrischilles, Elizabeth A

    2013-08-01

    Discuss the tradeoffs inherent in choosing a local area size when using a measure of local area practice style as an instrument in instrumental variable estimation when assessing treatment effectiveness. Assess the effectiveness of angiotensin converting-enzyme inhibitors and angiotensin receptor blockers on survival after acute myocardial infarction for Medicare beneficiaries using practice style instruments based on different-sized local areas around patients. We contrasted treatment effect estimates using different local area sizes in terms of the strength of the relationship between local area practice styles and individual patient treatment choices; and indirect assessments of the assumption violations. Using smaller local areas to measure practice styles exploits more treatment variation and results in smaller standard errors. However, if treatment effects are heterogeneous, the use of smaller local areas may increase the risk that local practice style measures are dominated by differences in average treatment effectiveness across areas and bias results toward greater effectiveness. Local area practice style measures can be useful instruments in instrumental variable analysis, but the use of smaller local area sizes to generate greater treatment variation may result in treatment effect estimates that are biased toward higher effectiveness. Assessment of whether ecological bias can be mitigated by changing local area size requires the use of outside data sources. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. Data-driven regions of interest for longitudinal change in frontotemporal lobar degeneration.

    PubMed

    Pankov, Aleksandr; Binney, Richard J; Staffaroni, Adam M; Kornak, John; Attygalle, Suneth; Schuff, Norbert; Weiner, Michael W; Kramer, Joel H; Dickerson, Bradford C; Miller, Bruce L; Rosen, Howard J

    2016-01-01

    Current research is investigating the potential utility of longitudinal measurement of brain structure as a marker of drug effect in clinical trials for neurodegenerative disease. Recent studies in Alzheimer's disease (AD) have shown that measurement of change in empirically derived regions of interest (ROIs) allows more reliable measurement of change over time compared with regions chosen a-priori based on known effects of AD on brain anatomy. Frontotemporal lobar degeneration (FTLD) is a devastating neurodegenerative disorder for which there are no approved treatments. The goal of this study was to identify an empirical ROI that maximizes the effect size for the annual rate of brain atrophy in FTLD compared with healthy age matched controls, and to estimate the effect size and associated power estimates for a theoretical study that would use change within this ROI as an outcome measure. Eighty six patients with FTLD were studied, including 43 who were imaged twice at 1.5 T and 43 at 3 T, along with 105 controls (37 imaged at 1.5 T and 67 at 3 T). Empirically-derived maps of change were generated separately for each field strength and included the bilateral insula, dorsolateral, medial and orbital frontal, basal ganglia and lateral and inferior temporal regions. The extent of regions included in the 3 T map was larger than that in the 1.5 T map. At both field strengths, the effect sizes for imaging were larger than for any clinical measures. At 3 T, the effect size for longitudinal change measured within the empirically derived ROI was larger than the effect sizes derived from frontal lobe, temporal lobe or whole brain ROIs. The effect size derived from the data-driven 1.5 T map was smaller than at 3 T, and was not larger than the effect size derived from a-priori ROIs. It was estimated that measurement of longitudinal change using 1.5 T MR systems requires approximately a 3-fold increase in sample size to obtain effect sizes equivalent to those seen at 3 T. While the results should be confirmed in additional datasets, these results indicate that empirically derived ROIs can reduce the number of subjects needed for a longitudinal study of drug effects in FTLD compared with a-priori ROIs. Field strength may have a significant impact on the utility of imaging for measuring longitudinal change.

  3. Effect of molecular exchange on water droplet size analysis as determined by diffusion NMR: The W/O/W double emulsion case.

    PubMed

    Vermeir, Lien; Sabatino, Paolo; Balcaen, Mathieu; Declerck, Arnout; Dewettinck, Koen; Martins, José C; Guthausen, Gisela; Van der Meeren, Paul

    2016-08-01

    The accuracy of the inner water droplet size determination of W/O/W emulsions upon water diffusion measurement by diffusion NMR was evaluated. The resulting droplet size data were compared to the results acquired from the diffusion measurement of a highly water soluble marker compound with low permeability in the oil layer of a W/O/W emulsion, which provide a closer representation of the actual droplet size. Differences in droplet size data obtained from water and the marker were ascribed to extra-droplet water diffusion. The diffusion data of the tetramethylammonium cation marker were measured using high-resolution pulsed field gradient NMR, whereas the water diffusion was measured using both low-resolution and high-resolution NMR. Different data analysis procedures were evaluated to correct for the effect of extra-droplet water diffusion on the accuracy of water droplet size analysis. Using the water diffusion data, the use of a low measurement temperature and diffusion delay Δ could reduce the droplet size overestimation resulting from extra-droplet water diffusion, but this undesirable effect was inevitable. Detailed analysis of the diffusion data revealed that the extra-droplet diffusion effect was due to an exchange between the inner water phase and the oil phase, rather than by exchange between the internal and external aqueous phase. A promising data analysis procedure for retrieving reliable size data consisted of the application of Einstein's diffusion law to the experimentally determined diffusion distances. This simple procedure allowed determining the inner water droplet size of W/O/W emulsions upon measurement of water diffusion by low-resolution NMR at or even above room temperature. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Effect Sizes and their Intervals: The Two-Level Repeated Measures Case

    ERIC Educational Resources Information Center

    Algina, James; Keselman, H. J.; Penfield, Randall D.

    2005-01-01

    Probability coverage for eight different confidence intervals (CIs) of measures of effect size (ES) in a two-level repeated measures design was investigated. The CIs and measures of ES differed with regard to whether they used least squares or robust estimates of central tendency and variability, whether the end critical points of the interval…

  5. Procedural Sensitivities of Effect Sizes for Single-Case Designs with Directly Observed Behavioral Outcome Measures

    ERIC Educational Resources Information Center

    Pustejovsky, James E.

    2018-01-01

    A wide variety of effect size indices have been proposed for quantifying the magnitude of treatment effects in single-case designs. Commonly used measures include parametric indices such as the standardized mean difference, as well as non-overlap measures such as the percentage of non-overlapping data, improvement rate difference, and non-overlap…

  6. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    NASA Astrophysics Data System (ADS)

    Atkinson, Dean B.; Pekour, Mikhail; Chand, Duli; Radney, James G.; Kolesar, Katheryn R.; Zhang, Qi; Setyan, Ari; O'Neill, Norman T.; Cappa, Christopher D.

    2018-04-01

    Multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES) are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare well with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM1 and PM10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.

  7. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    DOE PAGES

    Atkinson, Dean B.; Pekour, Mikhail; Chand, Duli; ...

    2018-04-23

    Here, multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES) are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare wellmore » with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM 1 and PM 10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.« less

  8. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atkinson, Dean B.; Pekour, Mikhail; Chand, Duli

    Here, multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES) are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare wellmore » with other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM 1 and PM 10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.« less

  9. Using spectral methods to obtain particle size information from optical data: applications to measurements from CARES 2010

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Atkinson, Dean B.; Pekour, Mikhail; Chand, Duli

    Multi-wavelength in situ aerosol extinction, absorption and scattering measurements made at two ground sites during the 2010 Carbonaceous Aerosols and Radiative Effects Study (CARES) are analyzed using a spectral deconvolution method that allows extraction of particle-size-related information, including the fraction of extinction produced by the fine-mode particles and the effective radius of the fine mode. The spectral deconvolution method is typically applied to analysis of remote sensing measurements. Here, its application to in situ measurements allows for comparison with more direct measurement methods and validation of the retrieval approach. Overall, the retrieved fine-mode fraction and effective radius compare well withmore » other in situ measurements, including size distribution measurements and scattering and absorption measurements made separately for PM 1 and PM 10, although there were some periods during which the different methods yielded different results. One key contributor to differences between the results obtained is the alternative, spectrally based definitions of fine and coarse modes from the optical methods, relative to instruments that use a physically defined cut point. These results indicate that for campaigns where size, composition and multi-wavelength optical property measurements are made, comparison of the results can result in closure or can identify unusual circumstances. The comparison here also demonstrates that in situ multi-wavelength optical property measurements can be used to determine information about particle size distributions in situations where direct size distribution measurements are not available.« less

  10. Experimental Effects on IR Reflectance Spectra: Particle Size and Morphology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beiswenger, Toya N.; Myers, Tanya L.; Brauer, Carolyn S.

    For geologic and extraterrestrial samples it is known that both particle size and morphology can have strong effects on the species’ infrared reflectance spectra. Due to such effects, the reflectance spectra cannot be predicted from the absorption coefficients alone. This is because reflectance is both a surface as well as a bulk phenomenon, incorporating both dispersion as well as absorption effects. The same spectral features can even be observed as either a maximum or minimum. The complex effects depend on particle size and preparation, as well as the relative amplitudes of the optical constants n and k, i.e. the realmore » and imaginary components of the complex refractive index. While somewhat oversimplified, upward-going amplitude in the reflectance spectrum usually result from surface scattering, i.e. rays that have been reflected from the surface without penetration, whereas downward-going peaks are due to either absorption or volume scattering, i.e. rays that have penetrated or refracted into the sample interior and are not reflected. While the effects are well known, we report seminal measurements of reflectance along with quantified particle size of the samples, the sizing obtained from optical microscopy measurements. The size measurements are correlated with the reflectance spectra in the 1.3 – 16 micron range for various bulk materials that have a combination of strong and weak absorption bands in order to understand the effects on the spectral features as a function of the mean grain size of the sample. We report results for both sodium sulfate Na2SO4 as well as ammonium sulfate (NH4)2SO4; the optical constants have been measured for (NH4)2SO4. To go a step further from the field to the laboratory we explore our understanding of particle size effects on reflectance spectra in the field using standoff detection. This has helped identify weaknesses and strengths in detection using standoff distances of up 160 meters away from the Target. The studies have shown that particle size has an enormous influence on the measured reflectance spectra of such materials; successful identification requires sufficient, representative reflectance data to include the particle sizes of interest.« less

  11. Standardized Effect Size Measures for Mediation Analysis in Cluster-Randomized Trials

    ERIC Educational Resources Information Center

    Stapleton, Laura M.; Pituch, Keenan A.; Dion, Eric

    2015-01-01

    This article presents 3 standardized effect size measures to use when sharing results of an analysis of mediation of treatment effects for cluster-randomized trials. The authors discuss 3 examples of mediation analysis (upper-level mediation, cross-level mediation, and cross-level mediation with a contextual effect) with demonstration of the…

  12. Propagation of Sound in Matter.

    DTIC Science & Technology

    1982-03-01

    Attenuation in Liquid Helium at 1 GHz; Technical Report No. 28, April 1969. 2. Kriss, Michael A., Size Effects in Liquid Helium II as Measured by Fourth...Helium, Technical Report No. 30, October 1969. 4. Scott, Stephen A., A Specific Heat and Fourth Sound Measurement of Size Effects in Liquid Helium...Rudnick, Superfluid Helmholtz Resonators, Phys. Rev. 174, No. 1, 326 (October 1968). 2. E. Guyon and I. Rudnick, Size Effects in Superfluid Helium II, Le

  13. Lambmeat colour values (HunterLab CIE and reflectance) are influenced by aperture size (5 mm v. 25 mm).

    PubMed

    Holman, Benjamin W B; Ponnampalam, Eric N; van de Ven, Remy J; Kerr, Matthew G; Hopkins, David L

    2015-02-01

    The effect of aperture size on the assessment of lamb meat colour values (L*, a*, b* and R630/580)was investigated. Two experiments using 2 HunterLab MiniScan colorimeters (large [25 mm] and small [5 mm] apertures) were conducted: 1) coloured tiles were measured and 2) unaged lamb (n = 65) m. longissimus lumborum (LL) and m. semimembranosus (SM) muscles were measured over 2.5 d under simulated retail display. For Experiment three, 2 different colorimeters were used on lamb (n = 36) LL aged for 6 weeks before measurement over 4 don simulated retail display. Coloured tile a* and b* values were unaffected by aperture size, but L* values and the R630/580 ratio were influenced by aperture size. The effect of aperture size on lamb meat colour measurements varied with display time and muscle type. The large aperture size generally provided the highest colorimetric values, and is recommended for measuring lamb meat colour.

  14. A practical and theoretical definition of very small field size for radiotherapy output factor measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Charles, P. H., E-mail: p.charles@qut.edu.au; Crowe, S. B.; Langton, C. M.

    Purpose: This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. Methods: A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated intomore » additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. Results: According to the practical definition established in this project, field sizes ≤15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤12 mm. Source occlusion also caused a large change in OPF for field sizes ≤8 mm. Based on the results of this study, field sizes ≤12 mm were considered to be theoretically very small for 6 MV beams. Conclusions: Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least ≤12 mm and more conservatively≤15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection.« less

  15. A practical and theoretical definition of very small field size for radiotherapy output factor measurements.

    PubMed

    Charles, P H; Cranmer-Sargison, G; Thwaites, D I; Crowe, S B; Kairn, T; Knight, R T; Kenny, J; Langton, C M; Trapp, J V

    2014-04-01

    This work introduces the concept of very small field size. Output factor (OPF) measurements at these field sizes require extremely careful experimental methodology including the measurement of dosimetric field size at the same time as each OPF measurement. Two quantifiable scientific definitions of the threshold of very small field size are presented. A practical definition was established by quantifying the effect that a 1 mm error in field size or detector position had on OPFs and setting acceptable uncertainties on OPF at 1%. Alternatively, for a theoretical definition of very small field size, the OPFs were separated into additional factors to investigate the specific effects of lateral electronic disequilibrium, photon scatter in the phantom, and source occlusion. The dominant effect was established and formed the basis of a theoretical definition of very small fields. Each factor was obtained using Monte Carlo simulations of a Varian iX linear accelerator for various square field sizes of side length from 4 to 100 mm, using a nominal photon energy of 6 MV. According to the practical definition established in this project, field sizes ≤ 15 mm were considered to be very small for 6 MV beams for maximal field size uncertainties of 1 mm. If the acceptable uncertainty in the OPF was increased from 1.0% to 2.0%, or field size uncertainties are 0.5 mm, field sizes ≤ 12 mm were considered to be very small. Lateral electronic disequilibrium in the phantom was the dominant cause of change in OPF at very small field sizes. Thus the theoretical definition of very small field size coincided to the field size at which lateral electronic disequilibrium clearly caused a greater change in OPF than any other effects. This was found to occur at field sizes ≤ 12 mm. Source occlusion also caused a large change in OPF for field sizes ≤ 8 mm. Based on the results of this study, field sizes ≤ 12 mm were considered to be theoretically very small for 6 MV beams. Extremely careful experimental methodology including the measurement of dosimetric field size at the same time as output factor measurement for each field size setting and also very precise detector alignment is required at field sizes at least ≤ 12 mm and more conservatively ≤ 15 mm for 6 MV beams. These recommendations should be applied in addition to all the usual considerations for small field dosimetry, including careful detector selection. © 2014 American Association of Physicists in Medicine.

  16. Effect-Size Measures and Meta-Analytic Thinking in Counseling Psychology Research

    ERIC Educational Resources Information Center

    Henson, Robin K.

    2006-01-01

    Effect sizes are critical to result interpretation and synthesis across studies. Although statistical significance testing has historically dominated the determination of result importance, modern views emphasize the role of effect sizes and confidence intervals. This article accessibly discusses how to calculate and interpret the effect sizes…

  17. VERTICAL BEAM SIZE CONTROL IN TLS AND TPS.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    KUO, C.C.; CHEN, J.R.; CHOU, P.J.

    2006-06-26

    Vertical beam size control is an important issue in the light source operations. The horizontal-vertical betatron coupling and vertical dispersion were measured and corrected to small values in the TLS 1.5 GeV storage ring. Estimated beam sizes are compared with the measured values. By employing an effective transverse damping system, the vertical beam blow-up due to transverse coherent instabilities, such as the fast-ion beam instability, was suppressed. As a result, the light source is very stable. In NSRRC we are designing an ultra low emittance 3-GeV storage ring and its designed vertical beam size could be as small as amore » few microns. The ground and mechanic vibration effects, and coherent instabilities could spoil the expected photon brightness due to blow-up of the vertical beam size if not well taken care of. The contributions of these effects to vertical beam size increase will be evaluated and the counter measures to minimize them will be proposed and reported in this paper.« less

  18. Overlap between treatment and control distributions as an effect size measure in experiments.

    PubMed

    Hedges, Larry V; Olkin, Ingram

    2016-03-01

    The proportion π of treatment group observations that exceed the control group mean has been proposed as an effect size measure for experiments that randomly assign independent units into 2 groups. We give the exact distribution of a simple estimator of π based on the standardized mean difference and use it to study the small sample bias of this estimator. We also give the minimum variance unbiased estimator of π under 2 models, one in which the variance of the mean difference is known and one in which the variance is unknown. We show how to use the relation between the standardized mean difference and the overlap measure to compute confidence intervals for π and show that these results can be used to obtain unbiased estimators, large sample variances, and confidence intervals for 3 related effect size measures based on the overlap. Finally, we show how the effect size π can be used in a meta-analysis. (c) 2016 APA, all rights reserved).

  19. Set-size procedures for controlling variations in speech-reception performance with a fluctuating masker

    PubMed Central

    Bernstein, Joshua G. W.; Summers, Van; Iyer, Nandini; Brungart, Douglas S.

    2012-01-01

    Adaptive signal-to-noise ratio (SNR) tracking is often used to measure speech reception in noise. Because SNR varies with performance using this method, data interpretation can be confounded when measuring an SNR-dependent effect such as the fluctuating-masker benefit (FMB) (the intelligibility improvement afforded by brief dips in the masker level). One way to overcome this confound, and allow FMB comparisons across listener groups with different stationary-noise performance, is to adjust the response set size to equalize performance across groups at a fixed SNR. However, this technique is only valid under the assumption that changes in set size have the same effect on percentage-correct performance for different masker types. This assumption was tested by measuring nonsense-syllable identification for normal-hearing listeners as a function of SNR, set size and masker (stationary noise, 4- and 32-Hz modulated noise and an interfering talker). Set-size adjustment had the same impact on performance scores for all maskers, confirming the independence of FMB (at matched SNRs) and set size. These results, along with those of a second experiment evaluating an adaptive set-size algorithm to adjust performance levels, establish set size as an efficient and effective tool to adjust baseline performance when comparing effects of masker fluctuations between listener groups. PMID:23039460

  20. THE EFFECTIVENESS OF QUADRATS FOR MEASURING VASCULAR PLANT DIVERSITY

    EPA Science Inventory

    Quadrats are widely used for measuring characteristics of vascular plant communities. It is well recognized that quadrat size affects measurements of frequency and cover. The ability of quadrats of varying sizes to adequately measure diversity has not been established. An exha...

  1. Finite-size analysis of continuous-variable measurement-device-independent quantum key distribution

    NASA Astrophysics Data System (ADS)

    Zhang, Xueying; Zhang, Yichen; Zhao, Yijia; Wang, Xiangyu; Yu, Song; Guo, Hong

    2017-10-01

    We study the impact of the finite-size effect on the continuous-variable measurement-device-independent quantum key distribution (CV-MDI QKD) protocol, mainly considering the finite-size effect on the parameter estimation procedure. The central-limit theorem and maximum likelihood estimation theorem are used to estimate the parameters. We also analyze the relationship between the number of exchanged signals and the optimal modulation variance in the protocol. It is proved that when Charlie's position is close to Bob, the CV-MDI QKD protocol has the farthest transmission distance in the finite-size scenario. Finally, we discuss the impact of finite-size effects related to the practical detection in the CV-MDI QKD protocol. The overall results indicate that the finite-size effect has a great influence on the secret-key rate of the CV-MDI QKD protocol and should not be ignored.

  2. Beyond Cohen's "d": Alternative Effect Size Measures for Between-Subject Designs

    ERIC Educational Resources Information Center

    Peng, Chao-Ying Joanne; Chen, Li-Ting

    2014-01-01

    Given the long history of discussion of issues surrounding statistical testing and effect size indices and various attempts by the American Psychological Association and by the American Educational Research Association to encourage the reporting of effect size, most journals in education and psychology have witnessed an increase in effect size…

  3. Effect Size in Efficacy Trials of Women With Decreased Sexual Desire.

    PubMed

    Pyke, Robert E; Clayton, Anita H

    2018-03-22

    Regarding hypoactive sexual desire disorder (HSDD) in women, some reviewers judge the effect size small for medications vs placebo, but substantial for cognitive behavior therapy (CBT) or mindfulness meditation training (MMT) vs wait list. However, we lack comparisons of the effect sizes for the active intervention itself, for the control treatment, and for the differential between the two. For efficacy trials of HSDD in women, compare effect sizes for medications (testosterone/testosterone transdermal system, flibanserin, and bremelanotide) and placebo vs effect sizes for psychotherapy and wait-list control. We conducted a literature search for mean changes and SD on main measures of sexual desire and associated distress in trials of medications, CBT, or MMT. Effect size was used as it measures the magnitude of the intervention without confounding by sample size. Cohen d was used to determine effect sizes. For medications, mean (SD) effect size was 1.0 (0.34); for CBT and MMT, 1.0 (0.36); for placebo, 0.55 (0.16); and for wait list, 0.05 (0.26). Recommendations of psychotherapy over medication for treatment of HSDD are premature and not supported by data on effect sizes. Active participation in treatment conveys considerable non-specific benefits. Caregivers should attend to biological and psychosocial elements, and patient preference, to optimize response. Few clinical trials of psychotherapies were substantial in size or utilized adequate control paradigms. Medications and psychotherapies had similar, large effect sizes. Effect size of placebo was moderate. Effect size of wait-list control was very small, about one quarter that of placebo. Thus, a substantial non-specific therapeutic effect is associated with receiving placebo plus active care and evaluation. The difference in effect size between placebo and wait-list controls distorts the value of the subtraction of effect of the control paradigms to estimate intervention effectiveness. Pyke RE, Clayton AH. Effect Size in Efficacy Trials of Women With Decreased Sexual Desire. Sex Med Rev 2018;XX:XXX-XXX. Copyright © 2018 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  4. Designing Adaptive Instructional Environments: Insights from Empirical Evidence

    DTIC Science & Technology

    2011-10-01

    theorems. Cohen’s f effect size for pretest to posttest gain, averaged across different problems = 0.46. 7 Basis for Adaptation Ability of...problems and took a posttest . Measures of Learning 26-item multiple choice pretest and posttest . Effect size on posttest scores as measured by...solving algebraic equations. Measures of Learning Pretest and posttest using rapid diagnostic testing procedure: Student had to provide their

  5. COMPARISON OF TWO PARTICLE-SIZE SPECTROMETERS FOR AMBIENT AEROSOL MEASUREMENTS. (R827354C002)

    EPA Science Inventory

    There is an ongoing debate on the question which size fraction of particles in ambient air may be responsible for human health effects observed in epidemiological studies. Since there is no single instrument available for the measurement of the particle-size distribution over ...

  6. Binary Logistic Regression Analysis for Detecting Differential Item Functioning: Effectiveness of R[superscript 2] and Delta Log Odds Ratio Effect Size Measures

    ERIC Educational Resources Information Center

    Hidalgo, Mª Dolores; Gómez-Benito, Juana; Zumbo, Bruno D.

    2014-01-01

    The authors analyze the effectiveness of the R[superscript 2] and delta log odds ratio effect size measures when using logistic regression analysis to detect differential item functioning (DIF) in dichotomous items. A simulation study was carried out, and the Type I error rate and power estimates under conditions in which only statistical testing…

  7. Choosing Assessment Instruments for Bulimia Practice and Outcome Research

    ERIC Educational Resources Information Center

    Sandberg, Katie; Erford, Bradley T.

    2013-01-01

    Six commonly used instruments for assessment of eating disorders were analyzed. Effect size results from Erford et al.'s (2013) meta-analysis for the treatment of bulimia nervosa were used to compare each scale's ability to measure treatment outcomes for bulimia nervosa. Effect size comparisons indicated higher overall effect sizes using the…

  8. Pilot application study of corridor performance indicators

    DOT National Transportation Integrated Search

    1998-09-16

    The need for effective multimodal performance indicators (or measures) is becoming increasingly important for adequate planning in all sizes of transportation environments, including small and medium-size communities. These measures are essential for...

  9. Calculating and reporting effect sizes to facilitate cumulative science: a practical primer for t-tests and ANOVAs

    PubMed Central

    Lakens, Daniël

    2013-01-01

    Effect sizes are the most important outcome of empirical studies. Most articles on effect sizes highlight their importance to communicate the practical significance of results. For scientists themselves, effect sizes are most useful because they facilitate cumulative science. Effect sizes can be used to determine the sample size for follow-up studies, or examining effects across studies. This article aims to provide a practical primer on how to calculate and report effect sizes for t-tests and ANOVA's such that effect sizes can be used in a-priori power analyses and meta-analyses. Whereas many articles about effect sizes focus on between-subjects designs and address within-subjects designs only briefly, I provide a detailed overview of the similarities and differences between within- and between-subjects designs. I suggest that some research questions in experimental psychology examine inherently intra-individual effects, which makes effect sizes that incorporate the correlation between measures the best summary of the results. Finally, a supplementary spreadsheet is provided to make it as easy as possible for researchers to incorporate effect size calculations into their workflow. PMID:24324449

  10. Sample Size Calculations for Precise Interval Estimation of the Eta-Squared Effect Size

    ERIC Educational Resources Information Center

    Shieh, Gwowen

    2015-01-01

    Analysis of variance is one of the most frequently used statistical analyses in the behavioral, educational, and social sciences, and special attention has been paid to the selection and use of an appropriate effect size measure of association in analysis of variance. This article presents the sample size procedures for precise interval estimation…

  11. Determination of refractive index, size, and concentration of nonabsorbing colloidal nanoparticles from measurements of the complex effective refractive index.

    PubMed

    Márquez-Islas, Roberto; Sánchez-Pérez, Celia; García-Valenzuela, Augusto

    2014-02-01

    We describe a method for obtaining the refractive index (RI), size, and concentration of nonabsorbing nanoparticles in suspension from relatively simple optical measurements. The method requires measuring the complex effective RI of two dilute suspensions of the particles in liquids of different refractive indices. We describe the theoretical basis of the proposed method and provide experimental results validating the procedure.

  12. Falling-stream turbidimeter as a means of measuring sediment concentrations in streams

    USGS Publications Warehouse

    Guy, Harold P.; Olson, Richard C.

    1972-01-01

    The ratio of suspended-sediment concentration to the square root of the median particle size of sand-sized sediments was found to be a useful parameter for elimination of the effect of particle size in the relative transparency-concentration relationships. Thus it was possible to evaluate the effect of the different type of sediment on the relative transparency independent of particle size. The use of this parameter to eliminate the effect of particle size was unsuccessful for finer sediments. -

  13. Effect of solvent and temperature on the size distribution of casein micelles measured by dynamic light scattering.

    PubMed

    Beliciu, C M; Moraru, C I

    2009-05-01

    The objectives of this study were to investigate the effect of the solvent on the accuracy of casein micelle particle size determination by dynamic light scattering (DLS) at different temperatures and to establish a clear protocol for these measurements. Dynamic light scattering analyses were performed at 6, 20, and 50 degrees C using a 90Plus Nanoparticle Size Analyzer (Brookhaven Instruments, Holtsville, NY). Raw and pasteurized skim milk were used as sources of casein micelles. Simulated milk ultrafiltrate, ultrafiltered water, and permeate obtained by ultrafiltration of skim milk using a 10-kDa cutoff membrane were used as solvents. The pH, ionic concentration, refractive index, and viscosity of all solvents were determined. The solvents were evaluated by DLS to ensure that they did not have a significant influence on the results of the particle size measurements. Experimental protocols were developed for accurate measurement of particle sizes in all solvents and experimental conditions. All measurements had good reproducibility, with coefficients of variation below 5%. Both the solvent and the temperature had a significant effect on the measured effective diameter of the casein micelles. When ultrafiltered permeate was used as a solvent, the particle size and polydispersity of casein micelles decreased as temperature increased. The effective diameter of casein micelles from raw skim milk diluted with ultrafiltered permeate was 176.4 +/- 5.3 nm at 6 degrees C, 177.4 +/- 1.9 nm at 20 degrees C, and 137.3 +/- 2.7 nm at 50 degrees C. This trend was justified by the increased strength of hydrophobic bonds with increasing temperature. Overall, the results of this study suggest that the most suitable solvent for the DLS analyses of casein micelles was casein-depleted ultrafiltered permeate. Dilution with water led to micelle dissociation, which significantly affected the DLS measurements, especially at 6 and 20 degrees C. Simulated milk ultrafiltrate seemed to give accurate results only at 20 degrees C. Results obtained in simulated milk ultrafiltrate at 6 degrees C could not be explained based on the known effects of temperature on the casein micelle, whereas at 50 degrees C, precipitation of amorphous calcium phosphate affected the DLS measurement.

  14. A meta-analysis of the effects of measuring theory of planned behaviour constructs on behaviour within prospective studies.

    PubMed

    Mankarious, Evon; Kothe, Emily

    2015-01-01

    Measurement reactivity effects, such as the mere measurement effect, have been proposed as a reason for behavioural changes in a number of theory of planned behaviour intervention studies. However, it is unclear whether such changes are the result of the mere measurement effect or of other artefacts of intervention study design. The aim of this study is to determine the size and direction of changes in health behaviours from baseline to follow-up in prospective studies using the theory of planned behaviour. Electronic databases were searched for the theory of planned behaviour studies which measured health behaviours at two or more time points. Change in behaviour was calculated for all studies. Sixty-six studies were included. Mean effect sizes across all studies were small and negative (d = -.03). Effect size was moderated by behaviour, behaviour type and follow-up length. Subgroup analyses showed significant decreases in socially undesirable behaviour (d = -.28), binge drinking (d = -.17), risk driving (d = -.20), sugar snack consumption (d = -.43) and sun-protective behaviour (d = -.18). Measurement of intention at baseline resulted in significant decreases in undesirable behaviour. Changes in undesirable behaviours reported in other studies may be the result of the mere measurement effect.

  15. Grain size effect on Lcr elastic wave for surface stress measurement of carbon steel

    NASA Astrophysics Data System (ADS)

    Liu, Bin; Miao, Wenbing; Dong, Shiyun; He, Peng

    2018-04-01

    Based on critical refraction longitudinal wave (Lcr wave) acoustoelastic theory, correction method for grain size effect on surface stress measurement was discussed in this paper. Two fixed distance Lcr wave transducers were used to collect Lcr wave, and difference in time of flight between Lcr waves was calculated with cross-correlation coefficient function, at last relationship of Lcr wave acoustoelastic coefficient and grain size was obtained. Results show that as grain size increases, propagation velocity of Lcr wave decreases, one cycle is optimal step length for calculating difference in time of flight between Lcr wave. When stress value is within stress turning point, relationship of difference in time of flight between Lcr wave and stress is basically consistent with Lcr wave acoustoelastic theory, while there is a deviation and it is higher gradually as stress increasing. Inhomogeneous elastic plastic deformation because of inhomogeneous microstructure and average value of surface stress in a fixed distance measured with Lcr wave were considered as the two main reasons for above results. As grain size increasing, Lcr wave acoustoelastic coefficient decreases in the form of power function, then correction method for grain size effect on surface stress measurement was proposed. Finally, theoretical discussion was verified by fracture morphology observation.

  16. Portion Size: Latest Developments and Interventions.

    PubMed

    Steenhuis, Ingrid; Poelman, Maartje

    2017-03-01

    The aim of this review is to provide an overview of (1) underlying mechanisms of the effect of portion size on energy intake, (2) external factors explaining the portion size effect and (3) interventions and measurements aimed at food portion size. Previous studies have shown that portion sizes have increased in recent decades. Many experimental studies have been conducted to unravel the mechanisms underlying the portion-size effect on food intake (e.g. the appropriateness mechanism, the 'unit bias' mechanism, the 'previous experience/expectation' mechanism, the 'visual cue' mechanism and the 'bite size' mechanism). In addition, external factors have been found to drive food portion selection and consumption (e.g. value for money, mindless eating, levels of awareness, estimation bias. Research on several interventions (ranging from 'providing information' to 'eliminating choice') have been conducted, but remain scarce, especially intervention studies in which portion size is a key focus in weight loss. Moreover, only three new instruments with respect to portion control behavior have been developed. There is considerable evidence for the portion-size effect on energy intake. However, the work on interventions targeting portion size and measurements for portion control behavior are limited. Moreover, from the literature it is not yet clear what type of interventions work best, for whom and in what context.

  17. Birth order, family size, and intelligence.

    PubMed

    Belmont, L; Marolla, F A

    1973-12-14

    The relation of birth order and family size to intellectual performance, as measured by the Raven Progressive Matrices, was examined among nearly all of 400,000 19-year-old males born in the Netherlands in 1944 through 1947. It was found that birth order and family size had independent effects on intellectual performance. Effects of family size were not present in all social classes, but effects of birth order were consistent across social class.

  18. Confidence Intervals for the Probability of Superiority Effect Size Measure and the Area under a Receiver Operating Characteristic Curve

    ERIC Educational Resources Information Center

    Ruscio, John; Mullen, Tara

    2012-01-01

    It is good scientific practice to the report an appropriate estimate of effect size and a confidence interval (CI) to indicate the precision with which a population effect was estimated. For comparisons of 2 independent groups, a probability-based effect size estimator (A) that is equal to the area under a receiver operating characteristic curve…

  19. Tumor size measured by preoperative ultrasonography and postoperative pathologic examination in papillary thyroid carcinoma: relative differences according to size, calcification and coexisting thyroiditis.

    PubMed

    Yoon, Young Hoon; Kwon, Ki Ryun; Kwak, Seo Young; Ryu, Kyeung A; Choi, Bobae; Kim, Jin-Man; Koo, Bon Seok

    2014-05-01

    Ultrasonography (US) is a useful diagnostic modality for evaluation of the size and features of thyroid nodules. Tumor size is a key indicator of the surgical extent of thyroid cancer. We evaluated the difference in tumor sizes measured by preoperative US and postoperative pathologic examination in papillary thyroid carcinoma (PTC). We reviewed the medical records of 172 consecutive patients, who underwent thyroidectomy for PTC treatment. We compared tumor size, as measured by preoperative US, with that in postoperative specimens. And we analyzed a number of factors potentially influencing the size measurement, including cancer size, calcification and coexisting thyroiditis. The mean size of the tumor measured by preoperative US was 11.4, and 10.2 mm by postoperative pathologic examination. The mean percentage difference (US-pathology/US) of tumor sizes measured by preoperative US and postoperative pathologic examination was 9.9 ± 19.3%, which was statistically significant (p < 0.001). When the effect of tumor size (≤10.0 vs. 10.1-20.0 vs. >20.0 mm) and the presence of calcification or coexisting thyroiditis on the tumor size discrepancy between the two measurements was analyzed, the mean percentage differences according to tumor size (9.1 vs. 11.2% vs. 9.8%, p = 0.842), calcification (9.2 vs. 10.2%, p = 0.756) and coexisting thyroiditis (17.6 vs. 9.5%, p = 0.223) did not show statistical significance. Tumor sizes measured in postoperative pathology were ~90% of those measured by preoperative US in PTC; this was not affected by tumor size, the presence of calcification or coexisting thyroiditis. When the surgical extent of PTC treatment according to tumor size measured by US is determined, the relative difference between tumor sizes measured by preoperative US and postoperative pathologic examination should be considered.

  20. Effectiveness of fishing gears to assess fish assemblage size structure in small lake ecosystems

    Treesearch

    T. A. Clement; K. Pangle; D. G. Uzarski; B. A. Murry

    2014-01-01

    Measurement of fish body-size distributions is increasingly used as a management tool to assess fishery status. However, the effects of gear selection on observed fish size structure has not received sufficient attention. Four different gear types (experimental gill nets, fine mesh bag seine, and two different sized mesh trap nets), which are commonly employed in the...

  1. Acute Respiratory Distress Syndrome Measurement Error. Potential Effect on Clinical Study Results

    PubMed Central

    Cooke, Colin R.; Iwashyna, Theodore J.; Hofer, Timothy P.

    2016-01-01

    Rationale: Identifying patients with acute respiratory distress syndrome (ARDS) is a recognized challenge. Experts often have only moderate agreement when applying the clinical definition of ARDS to patients. However, no study has fully examined the implications of low reliability measurement of ARDS on clinical studies. Objectives: To investigate how the degree of variability in ARDS measurement commonly reported in clinical studies affects study power, the accuracy of treatment effect estimates, and the measured strength of risk factor associations. Methods: We examined the effect of ARDS measurement error in randomized clinical trials (RCTs) of ARDS-specific treatments and cohort studies using simulations. We varied the reliability of ARDS diagnosis, quantified as the interobserver reliability (κ-statistic) between two reviewers. In RCT simulations, patients identified as having ARDS were enrolled, and when measurement error was present, patients without ARDS could be enrolled. In cohort studies, risk factors as potential predictors were analyzed using reviewer-identified ARDS as the outcome variable. Measurements and Main Results: Lower reliability measurement of ARDS during patient enrollment in RCTs seriously degraded study power. Holding effect size constant, the sample size necessary to attain adequate statistical power increased by more than 50% as reliability declined, although the result was sensitive to ARDS prevalence. In a 1,400-patient clinical trial, the sample size necessary to maintain similar statistical power increased to over 1,900 when reliability declined from perfect to substantial (κ = 0.72). Lower reliability measurement diminished the apparent effectiveness of an ARDS-specific treatment from a 15.2% (95% confidence interval, 9.4–20.9%) absolute risk reduction in mortality to 10.9% (95% confidence interval, 4.7–16.2%) when reliability declined to moderate (κ = 0.51). In cohort studies, the effect on risk factor associations was similar. Conclusions: ARDS measurement error can seriously degrade statistical power and effect size estimates of clinical studies. The reliability of ARDS measurement warrants careful attention in future ARDS clinical studies. PMID:27159648

  2. Impact of and correction for instrument sensitivity drift on nanoparticle size measurements by single-particle ICP-MS

    PubMed Central

    El Hadri, Hind; Petersen, Elijah J.; Winchester, Michael R.

    2016-01-01

    The effect of ICP-MS instrument sensitivity drift on the accuracy of NP size measurements using single particle (sp)ICP-MS is investigated. Theoretical modeling and experimental measurements of the impact of instrument sensitivity drift are in agreement and indicate that drift can impact the measured size of spherical NPs by up to 25 %. Given this substantial bias in the measured size, a method was developed using an internal standard to correct for the impact of drift and was shown to accurately correct for a decrease in instrument sensitivity of up to 50 % for 30 nm and 60 nm gold nanoparticles. PMID:26894759

  3. Technique for active measurement of atmospheric transmittance using an imaging system: implementation at 10.6-μm wavelength

    NASA Astrophysics Data System (ADS)

    Sadot, Dan; Zaarur, O.; Zaarur, S.; Kopeika, Norman S.

    1994-10-01

    An active method is presented for measuring atmospheric transmittance with an imaging system. In comparison to other measurement methods, this method has the advantage of immunity to background noise, independence of atmospheric conditions such as solar radiation, and an improved capability to evaluate effects of turbulence on the measurements. Other significant advantages are integration over all particulate size distribution effects including very small and very large particulates whose concentration is hard to measure, and the fact that this method is a path-integrated measurement. In this implementation attenuation deriving from molecular absorption and from small and large particulate scatter and absorption and their weather dependences are separated out. Preliminary results indicate high correlation with direct transmittance calculations via particle size distribution measurement, and that even at 10.6 micrometers wavelength atmospheric transmission depends noticeably on aerosol size distribution and concentration.

  4. A technique for active measurement of atmospheric transmittance using an imaging system: implementation at 10.6 μm wavelength

    NASA Astrophysics Data System (ADS)

    Sadot, D.; Zaarur, O.; Zaarur, S.

    1995-12-01

    An active method is presented for measuring atmospheric transmittance with an imaging system. In comparison to other measurement methods, this method has the advantage of immunity to background noise, independence of atmospheric conditions such as solar radiation, and an improved capability to evaluate effects of turbulence on the measurements. Other significant advantages are integration over all particulate size distribution effects including very small and very large particulates whose concentration is hard to measure, and the fact that this method is a path-integrated measurement. Attenuation deriving from molecular absorption and from small and large particulate scatter and absorption and their weather dependences are separated out. Preliminary results indicate high correlation with direct transmittance calculations via particle size distribution measurement, and that even at 10.6 μm wavelength atmospheric transmission depends noticeably on aerosol size distribution and concentration.

  5. Meta-Analysis with Complex Research Designs: Dealing with Dependence from Multiple Measures and Multiple Group Comparisons

    ERIC Educational Resources Information Center

    Scammacca, Nancy; Roberts, Greg; Stuebing, Karla K.

    2014-01-01

    Previous research has shown that treating dependent effect sizes as independent inflates the variance of the mean effect size and introduces bias by giving studies with more effect sizes more weight in the meta-analysis. This article summarizes the different approaches to handling dependence that have been advocated by methodologists, some of…

  6. On the effective point of measurement in megavoltage photon beams.

    PubMed

    Kawrakow, Iwan

    2006-06-01

    This paper presents a numerical investigation of the effective point of measurement of thimble ionization chambers in megavoltage photon beams using Monte Carlo simulations with the EGSNRC system. It is shown that the effective point of measurement for relative photon beam dosimetry depends on every detail of the chamber design, including the cavity length, the mass density of the wall material, and the size of the central electrode, in addition to the cavity radius. Moreover, the effective point of measurement also depends on the beam quality and the field size. The paper therefore argues that the upstream shift of 0.6 times the cavity radius, recommended in current dosimetry protocols, is inadequate for accurate relative photon beam dosimetry, particularly in the build-up region. On the other hand, once the effective point of measurement is selected appropriately, measured depth-ionization curves can be equated to measured depth-dose curves for all depths within +/- 0.5%.

  7. A standardized mean difference effect size for multiple baseline designs across individuals.

    PubMed

    Hedges, Larry V; Pustejovsky, James E; Shadish, William R

    2013-12-01

    Single-case designs are a class of research methods for evaluating treatment effects by measuring outcomes repeatedly over time while systematically introducing different condition (e.g., treatment and control) to the same individual. The designs are used across fields such as behavior analysis, clinical psychology, special education, and medicine. Emerging standards for single-case designs have focused attention on methods for summarizing and meta-analyzing findings and on the need for effect sizes indices that are comparable to those used in between-subjects designs. In the previous work, we discussed how to define and estimate an effect size that is directly comparable to the standardized mean difference often used in between-subjects research based on the data from a particular type of single-case design, the treatment reversal or (AB)(k) design. This paper extends the effect size measure to another type of single-case study, the multiple baseline design. We propose estimation methods for the effect size and its variance, study the estimators using simulation, and demonstrate the approach in two applications. Copyright © 2013 John Wiley & Sons, Ltd.

  8. Odds Ratio, Delta, ETS Classification, and Standardization Measures of DIF Magnitude for Binary Logistic Regression

    ERIC Educational Resources Information Center

    Monahan, Patrick O.; McHorney, Colleen A.; Stump, Timothy E.; Perkins, Anthony J.

    2007-01-01

    Previous methodological and applied studies that used binary logistic regression (LR) for detection of differential item functioning (DIF) in dichotomously scored items either did not report an effect size or did not employ several useful measures of DIF magnitude derived from the LR model. Equations are provided for these effect size indices.…

  9. Comparison of Ice Cloud Particle Sizes Retrieved From Satellite Data Derived From In Situ Measurements

    NASA Technical Reports Server (NTRS)

    Han, Qingyuan; Rossow, William B.; Chou, Joyce; Welch, Ronald M.

    1997-01-01

    Cloud microphysical parameterizations have attracted a great deal of attention in recent years due to their effect on cloud radiative properties and cloud-related hydrological processes in large-scale models. The parameterization of cirrus particle size has been demonstrated as an indispensable component in the climate feedback analysis. Therefore, global-scale, long-term observations of cirrus particle sizes are required both as a basis of and as a validation of parameterizations for climate models. While there is a global scale, long-term survey of water cloud droplet sizes (Han et al. 1994), there is no comparable study for cirrus ice crystals. In this paper a near-global survey of cirrus ice crystal sizes is conducted using ISCCP satellite data analysis. The retrieval scheme uses phase functions based upon hexagonal crystals calculated by a ray tracing technique. The results show that global mean values of D(e) are about 60 micro-m. This study also investigates the possible reasons for the significant difference between satellite retrieved effective radii (approx. 60 micro-m) and aircraft measured particle sizes (approx. 200 micro-m) during the FIRE I IFO experiment. They are (1) vertical inhomogeneity of cirrus particle sizes; (2) lower limit of the instrument used in aircraft measurements; (3) different definitions of effective particle sizes; and (4) possible inappropriate phase functions used in satellite retrieval.

  10. High correlations between MRI brain volume measurements based on NeuroQuant® and FreeSurfer.

    PubMed

    Ross, David E; Ochs, Alfred L; Tate, David F; Tokac, Umit; Seabaugh, John; Abildskov, Tracy J; Bigler, Erin D

    2018-05-30

    NeuroQuant ® (NQ) and FreeSurfer (FS) are commonly used computer-automated programs for measuring MRI brain volume. Previously they were reported to have high intermethod reliabilities but often large intermethod effect size differences. We hypothesized that linear transformations could be used to reduce the large effect sizes. This study was an extension of our previously reported study. We performed NQ and FS brain volume measurements on 60 subjects (including normal controls, patients with traumatic brain injury, and patients with Alzheimer's disease). We used two statistical approaches in parallel to develop methods for transforming FS volumes into NQ volumes: traditional linear regression, and Bayesian linear regression. For both methods, we used regression analyses to develop linear transformations of the FS volumes to make them more similar to the NQ volumes. The FS-to-NQ transformations based on traditional linear regression resulted in effect sizes which were small to moderate. The transformations based on Bayesian linear regression resulted in all effect sizes being trivially small. To our knowledge, this is the first report describing a method for transforming FS to NQ data so as to achieve high reliability and low effect size differences. Machine learning methods like Bayesian regression may be more useful than traditional methods. Copyright © 2018 Elsevier B.V. All rights reserved.

  11. MUDMASTER: A Program for Calculating Crystalline Size Distributions and Strain from the Shapes of X-Ray Diffraction Peaks

    USGS Publications Warehouse

    Eberl, D.D.; Drits, V.A.; Środoń, Jan; Nüesch, R.

    1996-01-01

    Particle size may strongly influence the physical and chemical properties of a substance (e.g. its rheology, surface area, cation exchange capacity, solubility, etc.), and its measurement in rocks may yield geological information about ancient environments (sediment provenance, degree of metamorphism, degree of weathering, current directions, distance to shore, etc.). Therefore mineralogists, geologists, chemists, soil scientists, and others who deal with clay-size material would like to have a convenient method for measuring particle size distributions. Nano-size crystals generally are too fine to be measured by light microscopy. Laser scattering methods give only average particle sizes; therefore particle size can not be measured in a particular crystallographic direction. Also, the particles measured by laser techniques may be composed of several different minerals, and may be agglomerations of individual crystals. Measurement by electron and atomic force microscopy is tedious, expensive, and time consuming. It is difficult to measure more than a few hundred particles per sample by these methods. This many measurements, often taking several days of intensive effort, may yield an accurate mean size for a sample, but may be too few to determine an accurate distribution of sizes. Measurement of size distributions by X-ray diffraction (XRD) solves these shortcomings. An X-ray scan of a sample occurs automatically, taking a few minutes to a few hours. The resulting XRD peaks average diffraction effects from billions of individual nano-size crystals. The size that is measured by XRD may be related to the size of the individual crystals of the mineral in the sample, rather than to the size of particles formed from the agglomeration of these crystals. Therefore one can determine the size of a particular mineral in a mixture of minerals, and the sizes in a particular crystallographic direction of that mineral.

  12. Questionnaire and behavioral task measures of impulsivity are differentially associated with body mass index: A comprehensive meta-analysis.

    PubMed

    Emery, Rebecca L; Levine, Michele D

    2017-08-01

    Although impulsivity has been implicated in the development and maintenance of obesity, evidence linking impulsivity to obesity has been mixed. These mixed findings may be related to differences in the type of impulsivity measures used and the varied domains of impulsivity assessed by each measure. The present meta-analysis aimed to examine the impact of measurement selection on the relationship between impulsivity and body mass index (BMI). A total of 142 articles met inclusion criteria and were comprised of 315,818 participants. Effect sizes consisted of Fisher's z-transformed correlation coefficients, which were weighted by the inverse variance to establish the grand mean estimate of the relationship between impulsivity and BMI. Overall weighted mean effect sizes also were computed for each type and domain of impulsivity measure. Moderator analyses were conducted using a mixed-effects approach to determine if the relationship between impulsivity and BMI varied between the types of impulsivity measures used. On average, participants were 32.25 (SD = 12.41) years of age, with a BMI of 26.63 (SD = 5.73) kg/m2. The overall relationship between impulsivity and BMI was small but significant (r = .07). Behavioral task measures of impulsivity produced significantly larger effect sizes (r = .10) than did questionnaire measures of impulsivity (r = .05). Domains of impulsivity that assessed disinhibited behaviors (r = .10), attentional deficits (r = .11), impulsive decision-making (r = .10), and cognitive inflexibility (r = .17) produced significant effect sizes. These meta-analytic findings demonstrate that impulsivity is positively associated with BMI and further document that this association varies by the type of impulsivity measure used and the domain of impulsivity assessed. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  13. Research on droplet size measurement of impulse antiriots water cannon based on sheet laser

    NASA Astrophysics Data System (ADS)

    Fa-dong, Zhao; Hong-wei, Zhuang; Ren-jun, Zhan

    2014-04-01

    As a new-style counter-personnel non-lethal weapon, it is the non-steady characteristic and large water mist field that increase the difficulty of measuring the droplet size distribution of impulse anti-riots water cannon which is the most important index to examine its tactical and technology performance. A method based on the technologies of particle scattering, sheet laser imaging and high speed handling was proposed and an universal droplet size measuring algorithm was designed and verified. According to this method, the droplet size distribution was measured. The measuring results of the size distribution under the same position with different timescale, the same axial distance with different radial distance, the same radial distance with different axial distance were analyzed qualitatively and some rational cause was presented. The droplet size measuring method proposed in this article provides a scientific and effective experiment method to ascertain the technical and tactical performance and optimize the relative system performance.

  14. The cost of large numbers of hypothesis tests on power, effect size and sample size.

    PubMed

    Lazzeroni, L C; Ray, A

    2012-01-01

    Advances in high-throughput biology and computer science are driving an exponential increase in the number of hypothesis tests in genomics and other scientific disciplines. Studies using current genotyping platforms frequently include a million or more tests. In addition to the monetary cost, this increase imposes a statistical cost owing to the multiple testing corrections needed to avoid large numbers of false-positive results. To safeguard against the resulting loss of power, some have suggested sample sizes on the order of tens of thousands that can be impractical for many diseases or may lower the quality of phenotypic measurements. This study examines the relationship between the number of tests on the one hand and power, detectable effect size or required sample size on the other. We show that once the number of tests is large, power can be maintained at a constant level, with comparatively small increases in the effect size or sample size. For example at the 0.05 significance level, a 13% increase in sample size is needed to maintain 80% power for ten million tests compared with one million tests, whereas a 70% increase in sample size is needed for 10 tests compared with a single test. Relative costs are less when measured by increases in the detectable effect size. We provide an interactive Excel calculator to compute power, effect size or sample size when comparing study designs or genome platforms involving different numbers of hypothesis tests. The results are reassuring in an era of extreme multiple testing.

  15. Sample Size Estimation: The Easy Way

    ERIC Educational Resources Information Center

    Weller, Susan C.

    2015-01-01

    This article presents a simple approach to making quick sample size estimates for basic hypothesis tests. Although there are many sources available for estimating sample sizes, methods are not often integrated across statistical tests, levels of measurement of variables, or effect sizes. A few parameters are required to estimate sample sizes and…

  16. Seed size effects on early seedling growth and response to applied nitrogen in annual ryegrass (Lolium multiflorum L.)

    USDA-ARS?s Scientific Manuscript database

    Use of individual plants as experimental units may be necessary when resources are limited, but inter-plant variation risks obscuring differences among treatments. Experiments were undertaken to measure the effects of seed size on seedling size and response to applied nitrogen of annual ryegrass (Lo...

  17. An experimental assessment of the size effects on the strength and ductility of freestanding copper films under macroscopically homogenous deformation

    NASA Astrophysics Data System (ADS)

    Chauhan, Shakti Singh

    Metallic interconnects and circuitry has been experiencing excessive deformation beyond their elastic limits in many applications, ranging from micro-electromechanical systems (MEMS) to flexible electronics. These broad applications are creating needs to understand the extent of strength and ductility of freestanding metallic films at scales approaching the micron and sub micron range. This work aims to elucidate the effects of microstructural constraint as well as geometric dimensional constraint on the strength and ductility of freestanding Cu films under uniaxial tension. Two types of films are tested (i) high purity rolled films of 12.5-100microm thickness and average grain sizes of 11-47microm and (ii) electroplated films of 2-50 microm thickness and average grain sizes of 1.8-5microm. Several experimental tools including residual electrical resistivity measurements, surface strain measurements and surface roughness measurements are employed to highlight the underlying deformation mechanisms leading to the observed size effects. With respect to the strength of the specimens, we find that the nature and magnitude of thickness effects is very sensitive to the average grain size. In all cases, coupled thickness and grain size effects were observed. This study shows that this observed coupling, unique to the case of freestanding specimen, arises because the observed size effects are an outcome of the size dependence of two fundamental microstructural parameters i.e. volume fraction of surface grains and grain boundary area per unit specimen volume. For films having thickness and grain sizes greater than 5microm, thickness dependent weakening is observed for a constant grain size. Reducing thickness results in an increase in the volume fraction of grains exposed to the free surface as well as a reduction in the grain boundary area per unit specimen volume. The former effect leads to a reduction in the effective microstructural constraint on the intragranular dislocation activity in individual grains. This free surface related effect is the origin of a weakening contribution to the overall specimen strength with reducing thickness. For specimens with grain sizes ˜ O (10-50microm), this effect was found to be dominating i.e. reducing thickness resulted in reducing strength. A phenomenological model employing the flow strength of surface and bulk grains is proposed to model the observed trends. For films having thickness and grain sizes smaller than 5microm, size dependent strengthening is observed for a constant grain size. At this scale, grain boundary dislocations dominate. As a consequence, thickness effects arise because grain boundary dislocation source density per unit specimen volume reduces with reducing specimen thickness. This statistical reduction in dislocation source density leads to increasing specimen strength via source starvation strengthening. Our results show that such increasing specimen strength with reducing thickness, which has only been observed previously for nanocrystalline thin films, first appears at average grain size of ˜5microm or xx smaller. The measurements showed a characteristic length scale of about 5microm, which defines the size dependent strengthening or weakening of the film. With respect to the thickness effects on ductility, it was found that both thickness and average grain size affect ductility. While prominent thickness effects persist at larger grain sizes, for specimens with grain size approaching 1microm, the loss of strain hardening ability at such fine microstructures dominates and a limiting ductility of ˜2% is seen irrespective of the thickness. The observed thickness effects on ductility were investigated via surface roughness measurements that allow the characterization of initiation and evolution of deformation heterogeneities. It was found that thickness has a strong influence on the characteristic heterogeneity of deformation. At small specimen thicknesses, the deformation was found to be highly localized i.e. widely spaced regions showing substantial thickness reduction, hence increasing the vulnerability to the onset of plastic instabilities. At larger thicknesses, however, the increasing microstructural constraint delocalizes the strain and thereby precludes the early onset of instability, leading to enhanced ductility.

  18. Thin and flexible active electrodes with shield for capacitive electrocardiogram measurement.

    PubMed

    Lee, Seung Min; Sim, Kyo Sik; Kim, Ko Keun; Lim, Yong Gyu; Park, Kwang Suk

    2010-05-01

    Capacitive electrocardiogram (ECG) measurement over clothing requires large electrodes that can remain in contact with curved body surfaces to increase the signal-to-noise ratio (SNR). In this article, we propose a new, thin, and flexible active electrode for use as a capacitive ECG measurement electrode. This electrode contains a shielding plate over its surface and it is extremely thin and can bend freely to cover larger body surfaces of the curve-shaped human torso. We evaluated the characteristics of flexible active electrodes under conditions of varying cloth thickness, electrode size, and contacting pressure. Electrodes of two sizes (45 and 12 cm(2)) were attached to a chest belt to measure the ECG from the human torso, and the results obtained for both the sizes were compared. Cloth thickness and electrode size showed a dominant effect on the SNR, whereas contacting pressure had almost no effect. The flexible active electrodes attached to chest belts wrapped closely and uniformly over the curved surface of the torso and SNR was increased with an increase in electrode size. Although the ECG signal became more distorted as the cloth thickness increased, the larger-sized flexible active electrode (45 cm(2)) showed less distortion than the smaller-sized one (12 cm(2)).

  19. An Alternative to Cohen's Standardized Mean Difference Effect Size: A Robust Parameter and Confidence Interval in the Two Independent Groups Case

    ERIC Educational Resources Information Center

    Algina, James; Keselman, H. J.; Penfield, Randall D.

    2005-01-01

    The authors argue that a robust version of Cohen's effect size constructed by replacing population means with 20% trimmed means and the population standard deviation with the square root of a 20% Winsorized variance is a better measure of population separation than is Cohen's effect size. The authors investigated coverage probability for…

  20. Responsiveness of outcome measures for upper limb prosthetic rehabilitation.

    PubMed

    Resnik, Linda; Borgia, Matthew

    2016-02-01

    There is limited research on responsiveness of prosthetic rehabilitation outcome measures. To examine responsiveness of the Box and Block test, Jebsen-Taylor Hand Function tests, Upper Extremity Functional Scale, University of New Brunswick skill and spontaneity tests, Activity Measure for Upper Limb Amputation, and the Patient-Specific Functional Scale. This was a quasi-experimental study with repeated measurements in a convenience sample of upper limb amputees. Measures were collected before, during, and after training with the DEKA Arm. Largest effect sizes were observed for Patient-Specific Functional Scale (effect size: 1.59, confidence interval: 1.00, 2.14), Activity Measure for Upper Limb Amputation (effect size: 1.33, confidence interval: 0.73, 1.90), and University of New Brunswick skill test (effect size: 1.18, confidence interval: 0.61, 1.73). Other measures that were responsive to change were Box and Block test, Jebsen-Taylor Hand Function light and heavy can tests, and University of New Brunswick spontaneity test. Responsiveness and pattern of responsiveness varied by prosthetic level. The Box and Block test, Jebsen-Taylor Hand Function light and heavy can tests, University of New Brunswick skill and spontaneity tests, Activities Measure for Upper Limb Amputation, and the Patient-Specific Functional Scale were responsive to change during prosthetic training. These findings have implications for choice of measures for research and practice and inform clinicians about the amount of training necessary to maximize outcomes with the DEKA Arm. Findings on responsiveness of outcome measures have implications for the choice of measures for clinical trials and practice. Findings regarding the responsiveness to change over the course of training can inform clinicians about the amount of training that may be necessary to maximize specific outcomes with the DEKA Arm. © The International Society for Prosthetics and Orthotics 2014.

  1. Inflammation response and cytotoxic effects in human THP-1 cells of size-fractionated PM10 extracts in a polluted urban site.

    PubMed

    Schilirò, T; Alessandria, L; Bonetta, S; Carraro, E; Gilli, G

    2016-02-01

    To contribute to a greater characterization of the airborne particulate matter's toxicity, size-fractionated PM10 was sampled during different seasons in a polluted urban site in Torino, a northern Italian city. Three main size fractions (PM10 - 3 μm; PM3 - 0.95 μm; PM < 0.95 μm) extracts (organic and aqueous) were assayed with THP-1 cells to evaluate their effects on cell proliferation, LDH activity, TNFα, IL-8 and CYP1A1 expression. The mean PM10 concentrations were statistically different in summer and in winter and the finest fraction PM<0.95 was always higher than the others. Size-fractionated PM10 extracts, sampled in an urban traffic meteorological-chemical station produced size-related toxicological effects in relation to season and particles extraction. The PM summer extracts induced a significant release of LDH compared to winter and produced a size-related effect, with higher values measured with PM10-3. Exposure to size-fractionated PM10 extracts did not induce significant expression of TNFα. IL-8 expression was influenced by exposure to size-fractionated PM10 extracts and statistically significant differences were found between kind of extracts for both seasons. The mean fold increases in CYP1A1 expression were statistically different in summer and in winter; winter fraction extracts produced a size-related effect, in particular for organic samples with higher values measured with PM<0.95 extracts. Our results confirm that the only measure of PM can be misleading for the assessment of air quality moreover we support efforts toward identifying potential effect-based tools (e.g. in vitro test) that could be used in the context of the different monitoring programs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Flight Investigation of the Effects of Pressure-Belt Tubing Size on Measured Pressure Distributions

    NASA Technical Reports Server (NTRS)

    Rivers, Natale A.; vanDam, Cornielious P.; Brown, Phillip W.; Rivers, Robert A.

    2001-01-01

    The pressure-belt technique is commonly used to measure pressure distributions on lifting and nonlifting surfaces where flush, through-the-surface measurements are not possible. The belts, made from strips of small-bore, flexible plastic tubing, are surface-mounted by a simple, nondestructive method. Additionally, the belts require minimal installation time, thus making them much less costly to install than flush-mounted pressure ports. Although pressure belts have been used in flight research since the early 1950s, only recently have manufacturers begun to produce thinner, more flexible tubing, and thin, strong adhesive tapes that minimize the installation-induced errors on the measurement of surface pressures. The objective of this investigation was to determine the effects of pressure-belt tubing size on the measurement of pressure distributions. For that purpose, two pressure belts were mounted on the right wing of a single-engine, propeller-driven research airplane. The outboard pressure belt served as a baseline for the measurement and the comparison of effects. Each tube had an outer diameter (OD) of 0.0625 in. The inboard belt was used to evaluate three different tube sizes: 0.0625-, 0.1250-, and 0.1875-in. OD. A computational investigation of tube size on pressure distribution also was conducted using the two-dimensional Multielement Streamtube Euler Solver (MSES) code.

  3. Characterizing the Joint Effect of Diverse Test-Statistic Correlation Structures and Effect Size on False Discovery Rates in a Multiple-Comparison Study of Many Outcome Measures

    NASA Technical Reports Server (NTRS)

    Feiveson, Alan H.; Ploutz-Snyder, Robert; Fiedler, James

    2011-01-01

    In their 2009 Annals of Statistics paper, Gavrilov, Benjamini, and Sarkar report the results of a simulation assessing the robustness of their adaptive step-down procedure (GBS) for controlling the false discovery rate (FDR) when normally distributed test statistics are serially correlated. In this study we extend the investigation to the case of multiple comparisons involving correlated non-central t-statistics, in particular when several treatments or time periods are being compared to a control in a repeated-measures design with many dependent outcome measures. In addition, we consider several dependence structures other than serial correlation and illustrate how the FDR depends on the interaction between effect size and the type of correlation structure as indexed by Foerstner s distance metric from an identity. The relationship between the correlation matrix R of the original dependent variables and R, the correlation matrix of associated t-statistics is also studied. In general R depends not only on R, but also on sample size and the signed effect sizes for the multiple comparisons.

  4. What is a species? A new universal method to measure differentiation and assess the taxonomic rank of allopatric populations, using continuous variables

    PubMed Central

    Donegan, Thomas M.

    2018-01-01

    Abstract Existing models for assigning species, subspecies, or no taxonomic rank to populations which are geographically separated from one another were analyzed. This was done by subjecting over 3,000 pairwise comparisons of vocal or biometric data based on birds to a variety of statistical tests that have been proposed as measures of differentiation. One current model which aims to test diagnosability (Isler et al. 1998) is highly conservative, applying a hard cut-off, which excludes from consideration differentiation below diagnosis. It also includes non-overlap as a requirement, a measure which penalizes increases to sample size. The “species scoring” model of Tobias et al. (2010) involves less drastic cut-offs, but unlike Isler et al. (1998), does not control adequately for sample size and attributes scores in many cases to differentiation which is not statistically significant. Four different models of assessing effect sizes were analyzed: using both pooled and unpooled standard deviations and controlling for sample size using t-distributions or omitting to do so. Pooled standard deviations produced more conservative effect sizes when uncontrolled for sample size but less conservative effect sizes when so controlled. Pooled models require assumptions to be made that are typically elusive or unsupported for taxonomic studies. Modifications to improving these frameworks are proposed, including: (i) introducing statistical significance as a gateway to attributing any weighting to findings of differentiation; (ii) abandoning non-overlap as a test; (iii) recalibrating Tobias et al. (2010) scores based on effect sizes controlled for sample size using t-distributions. A new universal method is proposed for measuring differentiation in taxonomy using continuous variables and a formula is proposed for ranking allopatric populations. This is based first on calculating effect sizes using unpooled standard deviations, controlled for sample size using t-distributions, for a series of different variables. All non-significant results are excluded by scoring them as zero. Distance between any two populations is calculated using Euclidian summation of non-zeroed effect size scores. If the score of an allopatric pair exceeds that of a related sympatric pair, then the allopatric population can be ranked as species and, if not, then at most subspecies rank should be assigned. A spreadsheet has been programmed and is being made available which allows this and other tests of differentiation and rank studied in this paper to be rapidly analyzed. PMID:29780266

  5. Variability in the Results of Meta-Analysis as a Function of Comparing Effect Sizes Based on Scores from Noncomparable Measures: A Simulation Study

    ERIC Educational Resources Information Center

    Nugent, William R.

    2017-01-01

    Meta-analysis is a significant methodological advance that is increasingly important in research synthesis. Fundamental to meta-analysis is the presumption that effect sizes, such as the standardized mean difference (SMD), based on scores from different measures are comparable. It has been argued that population observed score SMDs based on scores…

  6. A combined Settling Tube-Photometer for rapid measurement of effective sediment particle size

    NASA Astrophysics Data System (ADS)

    Kuhn, Nikolaus J.; Kuhn, Brigitte; Rüegg, Hans-Rudolf; Zimmermann, Lukas

    2017-04-01

    Sediment and its movement in water is commonly described based on the size distribution of the mineral particles forming the sediment. While this approach works for coarse sand, pebbles and gravel, smaller particles often form aggregates, creating material of larger diameters than the mineral grain size distribution indicates, but lower densities than often assumed 2.65 g cm-3 of quartz. The measurement of the actual size and density of such aggregated sediment is difficult. For the assessment of sediment movement an effective particle size for the use in mathematical can be derived based on the settling velocity of sediment. Settling velocity of commonly measured in settling tubes which fractionate the sample in settling velocity classes by sampling material at the base in selected time intervals. This process takes up to several hours, requires a laboratory setting and carries the risk of either destruction of aggregates during transport or coagulation while sitting in rather still water. Measuring the velocity of settling particles in situ, or at least a rapidly after collection, could avoids these problems. In this study, a settling tube equipped with four photometers used to measure the darkening of a settling particle cloud is presented and the potential to improve the measurement of settling velocities are discussed.

  7. Measuring Compartment Size and Gas Solubility in Marine Mammals

    DTIC Science & Technology

    2015-09-30

    bends? Effect of diving behaviour and physiology on modelled gas exchange for three species: Ziphius cavirostris, Mesoplodon densirostris and Hyperoodon...1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Measuring Compartment Size and Gas Solubility in Marine...is to develop methods to estimate marine mamal tissue compartment sizes, and tissue gas solubility. We aim to improve the data available for the

  8. Self-reported clothing size as a proxy measure for body size.

    PubMed

    Hughes, Laura A E; Schouten, Leo J; Goldbohm, R Alexandra; van den Brandt, Piet A; Weijenberg, Matty P

    2009-09-01

    Few studies have considered the potential utility of clothing size as a predictor of diseases associated with body weight. We used data on weight-stable men and women from a subcohort of the Netherlands Cohort Study to assess the correlation of clothing size with other anthropometric variables. Cox regression using the case-cohort approach was performed to establish whether clothing size can predict cancer risk after 13.3 years of follow-up, and if additionally considering body mass index (BMI) in the model improves the prediction. Trouser and skirt size correlated well with circumference measurements. Skirt size predicted endometrial cancer risk, and this effect was slightly attenuated when BMI was added to the model. Trouser size predicted risk of renal cell carcinoma, regardless of whether BMI was in the model. Clothing size appears to predict cancer risk independently of BMI, suggesting that clothing size is a useful measure to consider in epidemiologic studies when waist circumference is not available.

  9. An audit strategy for time-to-event outcomes measured with error: application to five randomized controlled trials in oncology.

    PubMed

    Dodd, Lori E; Korn, Edward L; Freidlin, Boris; Gu, Wenjuan; Abrams, Jeffrey S; Bushnell, William D; Canetta, Renzo; Doroshow, James H; Gray, Robert J; Sridhara, Rajeshwari

    2013-10-01

    Measurement error in time-to-event end points complicates interpretation of treatment effects in clinical trials. Non-differential measurement error is unlikely to produce large bias [1]. When error depends on treatment arm, bias is of greater concern. Blinded-independent central review (BICR) of all images from a trial is commonly undertaken to mitigate differential measurement-error bias that may be present in hazard ratios (HRs) based on local evaluations. Similar BICR and local evaluation HRs may provide reassurance about the treatment effect, but BICR adds considerable time and expense to trials. We describe a BICR audit strategy [2] and apply it to five randomized controlled trials to evaluate its use and to provide practical guidelines. The strategy requires BICR on a subset of study subjects, rather than a complete-case BICR, and makes use of an auxiliary-variable estimator. When the effect size is relatively large, the method provides a substantial reduction in the size of the BICRs. In a trial with 722 participants and a HR of 0.48, an average audit of 28% of the data was needed and always confirmed the treatment effect as assessed by local evaluations. More moderate effect sizes and/or smaller trial sizes required larger proportions of audited images, ranging from 57% to 100% for HRs ranging from 0.55 to 0.77 and sample sizes between 209 and 737. The method is developed for a simple random sample of study subjects. In studies with low event rates, more efficient estimation may result from sampling individuals with events at a higher rate. The proposed strategy can greatly decrease the costs and time associated with BICR, by reducing the number of images undergoing review. The savings will depend on the underlying treatment effect and trial size, with larger treatment effects and larger trials requiring smaller proportions of audited data.

  10. Ferroelectric properties of composites containing BaTiO 3 nanoparticles of various sizes

    NASA Astrophysics Data System (ADS)

    Adam, Jens; Lehnert, Tobias; Klein, Gabi; McMeeking, Robert M.

    2014-01-01

    Size effects, including the occurrence of superparaelectric phases associated with small scale, are a significant research topic for ferroelectrics. Relevant phenomena have been explored in detail, e.g. for homogeneous, thin ferroelectric films, but the related effects associated with nanoparticles are usually only inferred from their structural properties. In contrast, this paper describes all the steps and concepts necessary for the direct characterization and quantitative assessment of the ferroelectric properties of as-synthesized and as-received nanoparticles. The method adopted uses electrical polarization measurements on polymer matrix composites containing ferroelectric nanoparticles. It is applied to ten different BaTiO3 particle types covering a size range from 10 nm to 0.8 μm. The influence of variations of particle characteristics such as tetragonality and dielectric constant is considered based on measurements of these properties. For composites containing different particle types a clearly differing polarization behaviour is found. For decreasing particle size, increasing electric field is required to achieve a given level of polarization. The size dependence of a measure related to the coercive field revealed by this work is qualitatively in line with the state of the knowledge for ferroelectrics having small dimensions. For the first time, such results and size effects are described based on data from experiments on collections of actual nanoparticles.

  11. Effect Size Measures for Mediation Models: Quantitative Strategies for Communicating Indirect Effects

    ERIC Educational Resources Information Center

    Preacher, Kristopher J.; Kelley, Ken

    2011-01-01

    The statistical analysis of mediation effects has become an indispensable tool for helping scientists investigate processes thought to be causal. Yet, in spite of many recent advances in the estimation and testing of mediation effects, little attention has been given to methods for communicating effect size and the practical importance of those…

  12. Rigorous theoretical framework for particle sizing in turbid colloids using light refraction.

    PubMed

    García-Valenzuela, Augusto; Barrera, Rubén G; Gutierrez-Reyes, Edahí

    2008-11-24

    Using a non-local effective-medium approach, we analyze the refraction of light in a colloidal medium. We discuss the theoretical grounds and all the necessary precautions to design and perform experiments to measure the effective refractive index in dilute colloids. As an application, we show that it is possible to retrieve the size of small dielectric particles in a colloid by measuring the complex effective refractive index and the volume fraction occupied by the particles.

  13. Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

    PubMed Central

    Trattner, Sigal; Cheng, Bin; Pieniazek, Radoslaw L.; Hoffmann, Udo; Douglas, Pamela S.; Einstein, Andrew J.

    2014-01-01

    Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample size required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence. PMID:24694150

  14. Extinction-effective population index: incorporating life-history variations in population viability analysis.

    PubMed

    Fujiwara, Masami

    2007-09-01

    Viability status of populations is a commonly used measure for decision-making in the management of populations. One of the challenges faced by managers is the need to consistently allocate management effort among populations. This allocation should in part be based on comparison of extinction risks among populations. Unfortunately, common criteria that use minimum viable population size or count-based population viability analysis (PVA) often do not provide results that are comparable among populations, primarily because they lack consistency in determining population size measures and threshold levels of population size (e.g., minimum viable population size and quasi-extinction threshold). Here I introduce a new index called the "extinction-effective population index," which accounts for differential effects of demographic stochasticity among organisms with different life-history strategies and among individuals in different life stages. This index is expected to become a new way of determining minimum viable population size criteria and also complement the count-based PVA. The index accounts for the difference in life-history strategies of organisms, which are modeled using matrix population models. The extinction-effective population index, sensitivity, and elasticity are demonstrated in three species of Pacific salmonids. The interpretation of the index is also provided by comparing them with existing demographic indices. Finally, a measure of life-history-specific effect of demographic stochasticity is derived.

  15. Confidence intervals for single-case effect size measures based on randomization test inversion.

    PubMed

    Michiels, Bart; Heyvaert, Mieke; Meulders, Ann; Onghena, Patrick

    2017-02-01

    In the current paper, we present a method to construct nonparametric confidence intervals (CIs) for single-case effect size measures in the context of various single-case designs. We use the relationship between a two-sided statistical hypothesis test at significance level α and a 100 (1 - α) % two-sided CI to construct CIs for any effect size measure θ that contain all point null hypothesis θ values that cannot be rejected by the hypothesis test at significance level α. This method of hypothesis test inversion (HTI) can be employed using a randomization test as the statistical hypothesis test in order to construct a nonparametric CI for θ. We will refer to this procedure as randomization test inversion (RTI). We illustrate RTI in a situation in which θ is the unstandardized and the standardized difference in means between two treatments in a completely randomized single-case design. Additionally, we demonstrate how RTI can be extended to other types of single-case designs. Finally, we discuss a few challenges for RTI as well as possibilities when using the method with other effect size measures, such as rank-based nonoverlap indices. Supplementary to this paper, we provide easy-to-use R code, which allows the user to construct nonparametric CIs according to the proposed method.

  16. Improvement of photon correlation spectroscopy method for measuring nanoparticle size by using attenuated total reflectance.

    PubMed

    Krishtop, Victor; Doronin, Ivan; Okishev, Konstantin

    2012-11-05

    Photon correlation spectroscopy is an effective method for measuring nanoparticle sizes and has several advantages over alternative methods. However, this method suffers from a disadvantage in that its measuring accuracy reduces in the presence of convective flows of fluid containing nanoparticles. In this paper, we propose a scheme based on attenuated total reflectance in order to reduce the influence of convection currents. The autocorrelation function for the light-scattering intensity was found for this case, and it was shown that this method afforded a significant decrease in the time required to measure the particle sizes and an increase in the measuring accuracy.

  17. Effects of Class Size on Alternative Educational Outcomes across Disciplines

    ERIC Educational Resources Information Center

    Cheng, Dorothy A.

    2011-01-01

    This is the first study to use self-reported ratings of student learning, instructor recommendations, and course recommendations as the outcome measure to estimate class size effects, doing so across 24 disciplines. Fixed-effects models controlling for heterogeneous courses and instructors reveal that increasing enrollment has negative and…

  18. EFFECT OF RADIATION DOSE LEVEL ON ACCURACY AND PRECISION OF MANUAL SIZE MEASUREMENTS IN CHEST TOMOSYNTHESIS EVALUATED USING SIMULATED PULMONARY NODULES

    PubMed Central

    Söderman, Christina; Johnsson, Åse Allansdotter; Vikgren, Jenny; Norrlund, Rauni Rossi; Molnar, David; Svalkvist, Angelica; Månsson, Lars Gunnar; Båth, Magnus

    2016-01-01

    The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intraobserver variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. PMID:26994093

  19. EFFECT OF RADIATION DOSE LEVEL ON ACCURACY AND PRECISION OF MANUAL SIZE MEASUREMENTS IN CHEST TOMOSYNTHESIS EVALUATED USING SIMULATED PULMONARY NODULES.

    PubMed

    Söderman, Christina; Johnsson, Åse Allansdotter; Vikgren, Jenny; Norrlund, Rauni Rossi; Molnar, David; Svalkvist, Angelica; Månsson, Lars Gunnar; Båth, Magnus

    2016-06-01

    The aim of the present study was to investigate the dependency of the accuracy and precision of nodule diameter measurements on the radiation dose level in chest tomosynthesis. Artificial ellipsoid-shaped nodules with known dimensions were inserted in clinical chest tomosynthesis images. Noise was added to the images in order to simulate radiation dose levels corresponding to effective doses for a standard-sized patient of 0.06 and 0.04 mSv. These levels were compared with the original dose level, corresponding to an effective dose of 0.12 mSv for a standard-sized patient. Four thoracic radiologists measured the longest diameter of the nodules. The study was restricted to nodules located in high-dose areas of the tomosynthesis projection radiographs. A significant decrease of the measurement accuracy and intraobserver variability was seen for the lowest dose level for a subset of the observers. No significant effect of dose level on the interobserver variability was found. The number of non-measurable small nodules (≤5 mm) was higher for the two lowest dose levels compared with the original dose level. In conclusion, for pulmonary nodules at positions in the lung corresponding to locations in high-dose areas of the projection radiographs, using a radiation dose level resulting in an effective dose of 0.06 mSv to a standard-sized patient may be possible in chest tomosynthesis without affecting the accuracy and precision of nodule diameter measurements to any large extent. However, an increasing number of non-measurable small nodules (≤5 mm) with decreasing radiation dose may raise some concerns regarding an applied general dose reduction for chest tomosynthesis examinations in the clinical praxis. © The Author 2016. Published by Oxford University Press.

  20. Responsiveness of physical function outcomes following physiotherapy intervention for osteoarthritis of the knee: an outcome comparison study.

    PubMed

    French, Helen P; Fitzpatrick, Martina; FitzGerald, Oliver

    2011-12-01

    To compare the responsiveness of two self-report measures and three physical performance measures of function following physiotherapy for osteoarthritis of the knee. Single centre study in acute hospital setting. Patients referred for physiotherapy with osteoarthritis of the knee were recruited. The Western Ontario and McMaster Universities (WOMAC), Lequesne Algofunctional Index (LAI), timed-up-and-go test (TUGT), timed-stand test (TST) and six-minute walk test (6MWT) were administered at first and final physiotherapy visits. Wilcoxon Signed Rank tests were used to determine the effect of physiotherapy on each outcome. Responsiveness was calculated using effect size, standardised response mean and a median-based measure of responsiveness due to some outlying data. Thirty-nine patients with a mean age of 65.3 (standard deviation 6.9) years were investigated before and after a course of exercise-based physiotherapy. There was a significant improvement in all outcomes except the WOMAC scores. All measures demonstrated small effect sizes for all statistics (<0.50), except the 6MWT which was in the moderate range for one of the indices (standardised response mean 0.54). The LAI was more responsive than the WOMAC total score and the WOMAC physical function subscale for all responsiveness statistics, whilst the 6MWT was more responsive than the TST and the TUGT. The median-based effect size index produced the smallest effect sizes for all measures (0.1 to 0.43). These results can be used to guide decision making about which physical function outcome measures should be used to evaluate effectiveness of rehabilitation of people with osteoarthritis of the knee at group level in a clinical setting. Copyright © 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.

  1. Assessing the internal consistency of the event-related potential: An example analysis.

    PubMed

    Thigpen, Nina N; Kappenman, Emily S; Keil, Andreas

    2017-01-01

    ERPs are widely and increasingly used to address questions in psychophysiological research. As discussed in this special issue, a renewed focus on questions of reliability and stability marks the need for intuitive, quantitative descriptors that allow researchers to communicate the robustness of ERP measures used in a given study. This report argues that well-established indices of internal consistency and effect size meet this need and can be easily extracted from most ERP datasets, as demonstrated with example analyses using a representative dataset from a feature-based visual selective attention task. We demonstrate how to measure the internal consistency of three aspects commonly considered in ERP studies: voltage measurements for specific time ranges at selected sensors, voltage dynamics across all time points of the ERP waveform, and the distribution of voltages across the scalp. We illustrate methods for quantifying the robustness of experimental condition differences, by calculating effect size for different indices derived from the ERP. The number of trials contributing to the ERP waveform was manipulated to examine the relationship between signal-to-noise ratio (SNR), internal consistency, and effect size. In the present example dataset, satisfactory consistency (Cronbach's alpha > 0.7) of individual voltage measurements was reached at lower trial counts than were required to reach satisfactory effect sizes for differences between experimental conditions. Comparing different metrics of robustness, we conclude that the internal consistency and effect size of ERP findings greatly depend on the quantification strategy, the comparisons and analyses performed, and the SNR. © 2016 Society for Psychophysiological Research.

  2. Assessing the internal consistency of the event-related potential: An example analysis

    PubMed Central

    Thigpen, Nina; Kappenman, Emily; Keil, Andreas

    2017-01-01

    Event-related potentials (ERPs) are widely and increasingly used to address questions in Psychophysiological research. As discussed in this special issue, a renewed focus on questions of reliability and stability marks the need for intuitive, quantitative descriptors that allow researchers to communicate the robustness of ERP measures used in a given study. This report argues that well-established indices of internal consistency and effect size meet this need and can be easily extracted from most ERP data sets, as demonstrated with example analyses using a representative data set from a feature-based visual selective attention task. We demonstrate how to measure the internal consistency of three aspects commonly considered in ERP studies: Voltage measurements for specific time ranges at selected sensors, voltage dynamics across all time points of the ERP waveform, and the distribution of voltages across the scalp. We illustrate methods for quantifying the robustness of experimental condition differences, by calculating effect size for different indices derived from the ERP. The number of trials contributing to the ERP waveform was manipulated to examine the relationship between signal-to-noise ratio, internal consistency, and effect size. In the present example data set, satisfactory consistency (Cronbach’s alpha > 0.7) of individual voltage measurements was reached at lower trial counts than were required to reach satisfactory effect sizes for differences between experimental conditions. Comparing different metrics of robustness, we conclude that the SNR, internal consistency, and effect size of ERP findings greatly depend on the quantification strategy, the comparisons and analyses performed, and the signal-to-noise ratio. PMID:28000264

  3. Family size and effective population size in a hatchery stock of coho salmon (Oncorhynchus kisutch)

    USGS Publications Warehouse

    Simon, R.C.; McIntyre, J.D.; Hemmingsen, A.R.

    1986-01-01

    Means and variances of family size measured in five year-classes of wire-tagged coho salmon (Oncorhynchus kisutch) were linearly related. Population effective size was calculated by using estimated means and variances of family size in a 25-yr data set. Although numbers of age 3 adults returning to the hatchery appeared to be large enough to avoid inbreeding problems (the 25-yr mean exceeded 4500), the numbers actually contributing to the hatchery production may be too low. Several strategies are proposed to correct the problem perceived. Argument is given to support the contention that the problem of effective size is fairly general and is not confined to the present study population.

  4. Evaluation of Confluence Model Variables on IQ and Achievement Test Scores in a Sample of 6- to 11-Year-Old Children.

    ERIC Educational Resources Information Center

    Svanum, Soren; Bringle, Robert G.

    1980-01-01

    The confluence model of cognitive development was tested on 7,060 children. Family size, sibling order within family sizes, and hypothesized age-dependent effects were tested. Findings indicated an inverse relationship between family size and the cognitive measures; age-dependent effects and other confluence variables were found to be…

  5. Measuring true Young's modulus of a cantilevered nanowire: effect of clamping on resonance frequency.

    PubMed

    Qin, Qingquan; Xu, Feng; Cao, Yongqing; Ro, Paul I; Zhu, Yong

    2012-08-20

    The effect of clamping on resonance frequency and thus measured Young's modulus of nanowires (NWs) is systematically investigated via a combined experimental and simulation approach. ZnO NWs are used in this work as an example. The resonance tests are performed in situ inside a scanning electron microscope and the NWs are cantilevered on a tungsten probe by electron-beam-induced deposition (EBID) of hydrocarbon. EBID is repeated several times to deposit more hydrocarbons at the same location. The resonance frequency increases with the increasing clamp size until approaching that under the "fixed" boundary condition. The critical clamp size is identified as a function of NW diameter and NW Young's modulus. This work: 1) exemplifies the importance of considering the effect of clamping in measurements of Young's modulus using the resonance method, and 2) demonstrates that the true Young's modulus can be measured if the critical clamp size is reached. Design guidelines on the critical clamp size are provided. Such design guidelines can be extended to other one-dimensional nanostructures such as carbon nanotubes. Copyright © 2012 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  6. Effects of aggregate morphology and size on laser-induced incandescence and scattering from black carbon (mature soot)

    DOE PAGES

    Bambha, Ray P.; Michelsen, Hope A.

    2015-07-03

    We have used a Single-Particle Soot Photometer (SP2) to measure time-resolved laser-induced incandescence (LII) and laser scatter from combustion-generated mature soot with a fractal dimension of 1.88 extracted from a burner. We have also made measurements on restructured mature-soot particles with a fractal dimension of 2.3–2.4. We reproduced the LII and laser-scatter temporal profiles with an energy- and mass-balance model, which accounted for heating of particles passed through a CW-laser beam over laser–particle interaction times of ~10 μs. Furthermore, the results demonstrate a strong influence of aggregate size and morphology on LII and scattering signals. Conductive cooling competes with absorptivemore » heating on these time scales; the effects are reduced with increasing aggregate size and fractal dimension. These effects can lead to a significant delay in the onset of the LII signal and may explain an apparent low bias in the SP2 measurements for small particle sizes, particularly for fresh, mature soot. The results also reveal significant perturbations to the measured scattering signal from LII interference and suggest rapid expansion of the aggregates during sublimation.« less

  7. Method to optimize patch size based on spatial frequency response in image rendering of the light field

    NASA Astrophysics Data System (ADS)

    Zhang, Wei; Wang, Yanan; Zhu, Zhenhao; Su, Jinhui

    2018-05-01

    A focused plenoptic camera can effectively transform angular and spatial information to yield a refocused rendered image with high resolution. However, choosing a proper patch size poses a significant problem for the image-rendering algorithm. By using a spatial frequency response measurement, a method to obtain a suitable patch size is presented. By evaluating the spatial frequency response curves, the optimized patch size can be obtained quickly and easily. Moreover, the range of depth over which images can be rendered without artifacts can be estimated. Experiments show that the results of the image rendered based on frequency response measurement are in accordance with the theoretical calculation, which indicates that this is an effective way to determine the patch size. This study may provide support to light-field image rendering.

  8. Impact of encoding depth on awareness of perceptual effects in recognition memory.

    PubMed

    Gardiner, J M; Gregg, V H; Mashru, R; Thaman, M

    2001-04-01

    Pictorial stimuli are more likely to be recognized if they are the same size, rather than a different size, at study and at test. This size congruency effect was replicated in two experiments in which the encoding variables were respectively undivided versus divided attention and level of processing. In terms of performance, these variables influenced recognition and did not influence size congruency effects. But in terms of awareness, measured by remember and know responses, these variables did influence size congruency effects. With undivided attention and with a deep level of processing, size congruency effects occurred only in remembering. With divided attention and with a shallow level of processing, size congruency effects occurred only in knowing. The results show that effects that occur in remembering may also occur independently in knowing. They support theories in which remembering and knowing reflect different memory processes or systems. They do not support the theory that remembering and knowing reflect differences in trace strength.

  9. Electrical tuning of a quantum plasmonic resonance

    DOE PAGES

    Liu, Xiaoge; Kang, Ju -Hyung; Yuan, Hongtao; ...

    2017-06-12

    Surface plasmon (SP) excitations in metals facilitate confinement of light into deep-subwavelength volumes and can induce strong light–matter interaction. Generally, the SP resonances supported by noble metal nanostructures are explained well by classical models, at least until the nanostructure size is decreased to a few nanometres, approaching the Fermi wavelength λ F of the electrons. Although there is a long history of reports on quantum size effects in the plasmonic response of nanometre-sized metal particles systematic experimental studies have been hindered by inhomogeneous broadening in ensemble measurements, as well as imperfect control over size, shape, faceting, surface reconstructions, contamination, chargingmore » effects and surface roughness in single-particle measurements. In particular, observation of the quantum size effect in metallic films and its tuning with thickness has been challenging as they only confine carriers in one direction. Here, we show active tuning of quantum size effects in SP resonances supported by a 20-nm-thick metallic film of indium tin oxide (ITO), a plasmonic material serving as a low-carrier-density Drude metal. An ionic liquid (IL) is used to electrically gate and partially deplete the ITO layer. The experiment shows a controllable and reversible blue-shift in the SP resonance above a critical voltage. As a result, a quantum-mechanical model including the quantum size effect reproduces the experimental results, whereas a classical model only predicts a red shift.« less

  10. Electrical tuning of a quantum plasmonic resonance

    NASA Astrophysics Data System (ADS)

    Liu, Xiaoge; Kang, Ju-Hyung; Yuan, Hongtao; Park, Junghyun; Kim, Soo Jin; Cui, Yi; Hwang, Harold Y.; Brongersma, Mark L.

    2017-09-01

    Surface plasmon (SP) excitations in metals facilitate confinement of light into deep-subwavelength volumes and can induce strong light-matter interaction. Generally, the SP resonances supported by noble metal nanostructures are explained well by classical models, at least until the nanostructure size is decreased to a few nanometres, approaching the Fermi wavelength λF of the electrons. Although there is a long history of reports on quantum size effects in the plasmonic response of nanometre-sized metal particles, systematic experimental studies have been hindered by inhomogeneous broadening in ensemble measurements, as well as imperfect control over size, shape, faceting, surface reconstructions, contamination, charging effects and surface roughness in single-particle measurements. In particular, observation of the quantum size effect in metallic films and its tuning with thickness has been challenging as they only confine carriers in one direction. Here, we show active tuning of quantum size effects in SP resonances supported by a 20-nm-thick metallic film of indium tin oxide (ITO), a plasmonic material serving as a low-carrier-density Drude metal. An ionic liquid (IL) is used to electrically gate and partially deplete the ITO layer. The experiment shows a controllable and reversible blue-shift in the SP resonance above a critical voltage. A quantum-mechanical model including the quantum size effect reproduces the experimental results, whereas a classical model only predicts a red shift.

  11. Theoretical and experimental analyses to determine the effects of crystal orientation and grain size on the thermoelectric properties of oblique deposited bismuth telluride thin films

    NASA Astrophysics Data System (ADS)

    Morikawa, Satoshi; Satake, Yuji; Takashiri, Masayuki

    2018-06-01

    The effects of crystal orientation and grain size on the thermoelectric properties of Bi2Te3 thin films were investigated by conducting experimental and theoretical analyses. To vary the crystal orientation and grain size, we performed oblique deposition, followed by thermal annealing treatment. The crystal orientation decreased as the oblique angle was increased, while the grain size was not changed significantly. The thermoelectric properties were measured at room temperature. A theoretical analysis was performed using a first principles method based on density functional theory. Then the semi-classical Boltzmann transport equation was used in the relaxation time approximation, with the effect of grain size included. Furthermore, the effect of crystal orientation was included in the calculation based on a simple semi-experimental model. A maximum power factor of 11.6 µW/(cm·K2) was obtained at an oblique angle of 40°. The calculated thermoelectric properties were in very good agreement with the experimentally measured values.

  12. A d-statistic for single-case designs that is equivalent to the usual between-groups d-statistic.

    PubMed

    Shadish, William R; Hedges, Larry V; Pustejovsky, James E; Boyajian, Jonathan G; Sullivan, Kristynn J; Andrade, Alma; Barrientos, Jeannette L

    2014-01-01

    We describe a standardised mean difference statistic (d) for single-case designs that is equivalent to the usual d in between-groups experiments. We show how it can be used to summarise treatment effects over cases within a study, to do power analyses in planning new studies and grant proposals, and to meta-analyse effects across studies of the same question. We discuss limitations of this d-statistic, and possible remedies to them. Even so, this d-statistic is better founded statistically than other effect size measures for single-case design, and unlike many general linear model approaches such as multilevel modelling or generalised additive models, it produces a standardised effect size that can be integrated over studies with different outcome measures. SPSS macros for both effect size computation and power analysis are available.

  13. Effect of crystal size distribution on thermoelectric performance for Lanthanum-doped strontium titanate bulk material

    NASA Astrophysics Data System (ADS)

    Zhang, Boyu; Wang, Jun; Yaer, Xinba; Huo, Zhenzhen; Wu, Yin; Li, Yan; Miao, Lei; Liu, Chengyan; Zou, Tao; Ma, Wen

    2015-07-01

    Effect of crystal size distribution on thermoelectric performance of Lanthanum-doped strontium titanate (La-SrTiO3) ceramics are investigated in this study. Thermoelectric performance measurement, coupled with microstructure studies, shows that the electrical conductivity strongly depends on the crystal size, potential barrier on the grain boundary and porosity. Meantime, because the average potential barriers height are increased along with the reduction of crystal size, the Seebeck coefficients are increased by energy filtering effect at the large number of grain boundaries. As a result, by controlling of crystal size distribution, ZT value of La-SrTiO3 is improved.

  14. Effect of subcutaneous Enoxaparin injection duration on bruising size in acute coronary syndrome patients.

    PubMed

    Dehghani, Khadije; Najari, Zahra; Dehghani, Hamideh

    2014-11-01

    Bruising is an unpleasant result of subcutaneous injection of Enoxaparin, which causes physical discomfort, limitation of injection site, patient's refusal of treatment, and distrust in nurses' ability. The application of techniques which reduce patients' fear, anxiety, and physical damage is one of the tasks of nurses. This clinical trial investigated the effect of duration of subcutaneous Enoxaparin injection on the bruising size in acute coronary syndrome patients. Seventy 35-75-year-old acute coronary syndrome patients hospitalized in Coronary Care Units were selected randomly. Each subject received 10- and 30-sec duration of injections by a single researcher on both sides of the abdomen in 12-h intervals. The bruising size was measured using a transparent millimeter measuring paper, 24 and 48 h after each injection. Data were gathered by a data recording form (demographic and measurements data) and analyzed by descriptive statistics and non-parametric tests through SPSS. Results showed that the mean bruising sizes at 24 h after 10- and 30-sec injection were 33.26 mm(2) (72.77) and 48.96 mm(2) (99.91), respectively, and at 48 h were 15.61 mm(2) (142.02) and 52.48 mm(2) (143), respectively. There was no significant relationship between the two techniques (P > 0.05), although the effect of age on bruising size was significant (P = 0.01). According to the findings of the present study, length of Enoxaparin subcutaneous injection has no effect on the bruising size.

  15. On the repeated measures designs and sample sizes for randomized controlled trials.

    PubMed

    Tango, Toshiro

    2016-04-01

    For the analysis of longitudinal or repeated measures data, generalized linear mixed-effects models provide a flexible and powerful tool to deal with heterogeneity among subject response profiles. However, the typical statistical design adopted in usual randomized controlled trials is an analysis of covariance type analysis using a pre-defined pair of "pre-post" data, in which pre-(baseline) data are used as a covariate for adjustment together with other covariates. Then, the major design issue is to calculate the sample size or the number of subjects allocated to each treatment group. In this paper, we propose a new repeated measures design and sample size calculations combined with generalized linear mixed-effects models that depend not only on the number of subjects but on the number of repeated measures before and after randomization per subject used for the analysis. The main advantages of the proposed design combined with the generalized linear mixed-effects models are (1) it can easily handle missing data by applying the likelihood-based ignorable analyses under the missing at random assumption and (2) it may lead to a reduction in sample size, compared with the simple pre-post design. The proposed designs and the sample size calculations are illustrated with real data arising from randomized controlled trials. © The Author 2015. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  16. Practical performance of real-time shot-noise measurement in continuous-variable quantum key distribution

    NASA Astrophysics Data System (ADS)

    Wang, Tao; Huang, Peng; Zhou, Yingming; Liu, Weiqi; Zeng, Guihua

    2018-01-01

    In a practical continuous-variable quantum key distribution (CVQKD) system, real-time shot-noise measurement (RTSNM) is an essential procedure for preventing the eavesdropper exploiting the practical security loopholes. However, the performance of this procedure itself is not analyzed under the real-world condition. Therefore, we indicate the RTSNM practical performance and investigate its effects on the CVQKD system. In particular, due to the finite-size effect, the shot-noise measurement at the receiver's side may decrease the precision of parameter estimation and consequently result in a tight security bound. To mitigate that, we optimize the block size for RTSNM under the ensemble size limitation to maximize the secure key rate. Moreover, the effect of finite dynamics of amplitude modulator in this scheme is studied and its mitigation method is also proposed. Our work indicates the practical performance of RTSNM and provides the real secret key rate under it.

  17. Body size as a latent variable in a structural equation model: thermal acclimation and energetics of the leaf-eared mouse.

    PubMed

    Nespolo, Roberto F; Arim, Matías; Bozinovic, Francisco

    2003-07-01

    Body size is one of the most important determinants of energy metabolism in mammals. However, the usual physiological variables measured to characterize energy metabolism and heat dissipation in endotherms are strongly affected by thermal acclimation, and are also correlated among themselves. In addition to choosing the appropriate measurement of body size, these problems create additional complications when analyzing the relationships among physiological variables such as basal metabolism, non-shivering thermogenesis, thermoregulatory maximum metabolic rate and minimum thermal conductance, body size dependence, and the effect of thermal acclimation on them. We measured these variables in Phyllotis darwini, a murid rodent from central Chile, under conditions of warm and cold acclimation. In addition to standard statistical analyses to determine the effect of thermal acclimation on each variable and the body-mass-controlled correlation among them, we performed a Structural Equation Modeling analysis to evaluate the effects of three different measurements of body size (body mass, m(b); body length, L(b) and foot length, L(f)) on energy metabolism and thermal conductance. We found that thermal acclimation changed the correlation among physiological variables. Only cold-acclimated animals supported our a priori path models, and m(b) appeared to be the best descriptor of body size (compared with L(b) and L(f)) when dealing with energy metabolism and thermal conductance. However, while m(b) appeared to be the strongest determinant of energy metabolism, there was an important and significant contribution of L(b) (but not L(f)) to thermal conductance. This study demonstrates how additional information can be drawn from physiological ecology and general organismal studies by applying Structural Equation Modeling when multiple variables are measured in the same individuals.

  18. Macular Ganglion Cell Imaging Study: Covariate Effects on the Spectral Domain Optical Coherence Tomography for Glaucoma Diagnosis.

    PubMed

    Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung; Jeoung, Jin Wook

    2016-01-01

    To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size.

  19. Verification of the grid size and angular increment effects in lung stereotactic body radiation therapy using the dynamic conformal arc technique

    NASA Astrophysics Data System (ADS)

    Park, Hae-Jin; Suh, Tae-Suk; Park, Ji-Yeon; Lee, Jeong-Woo; Kim, Mi-Hwa; Oh, Young-Taek; Chun, Mison; Noh, O. Kyu; Suh, Susie

    2013-06-01

    The dosimetric effects of variable grid size and angular increment were systematically evaluated in the measured dose distributions of dynamic conformal arc therapy (DCAT) for lung stereotactic body radiation therapy (SBRT). Dose variations with different grid sizes (2, 3, and 4 mm) and angular increments (2, 4, 6, and 10°) for spherical planning target volumes (PTVs) were verified in a thorax phantom by using EBT2 films. Although the doses for identical PTVs were predicted for the different grid sizes, the dose discrepancy was evaluated using one measured dose distribution with the gamma tool because the beam was delivered in the same set-up for DCAT. The dosimetric effect of the angular increment was verified by comparing the measured dose area histograms of organs at risk (OARs) at each angular increment. When the difference in the OAR doses is higher than the uncertainty of the film dosimetry, the error is regarded as the angular increment effect in discretely calculated doses. In the results, even when a 2-mm grid size was used with an elaborate dose calculation, 4-mm grid size led to a higher gamma pass ratio due to underdosage, a steep-dose descent gradient, and lower estimated PTV doses caused by the smoothing effect in the calculated dose distribution. An undulating dose distribution and a difference in the maximum contralateral lung dose of up to 14% were observed in dose calculation using a 10° angular increment. The DCAT can be effectively applied for an approximately spherical PTV in a relatively uniform geometry, which is less affected by inhomogeneous materials and differences in the beam path length.

  20. Morphology of meteoroid and space debris craters on LDEF metal targets

    NASA Technical Reports Server (NTRS)

    Love, S. G.; Brownlee, D. E.; King, N. L.; Hoerz, F.

    1994-01-01

    We measured the depths, average diameters, and circularity indices of over 600 micrometeoroid and space debris craters on various metal surfaces exposed to space on the Long Duration Exposure Facility (LDEF) satellite, as a test of some of the formalisms used to convert the diameters of craters on space-exposed surfaces into penetration depths for the purpose of calculating impactor sizes or masses. The topics covered include the following: targe materials orientation; crater measurements and sample populations; effects of oblique impacts; effects of projectile velocity; effects of crater size; effects of target hardness; effects of target density; and effects of projectile properties.

  1. Treatment Trials for Neonatal Seizures: The Effect of Design on Sample Size

    PubMed Central

    Stevenson, Nathan J.; Boylan, Geraldine B.; Hellström-Westas, Lena; Vanhatalo, Sampsa

    2016-01-01

    Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (Td) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7–40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 (IQR: 1.9–11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7–2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4–3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size. PMID:27824913

  2. Suppression of agglomeration in fluidized bed coating. II. Measurement of mist size in a fluidized bed chamber and effect of sodium chloride addition on mist size.

    PubMed

    Yuasa, H; Nakano, T; Kanaya, Y

    1999-02-01

    It has been reported that the degree of particle agglomeration in fluidized bed coating is greatly affected by the spray mist size of coating solution. However, the mist size has generally been measured in open air, and few reports have described the measurement of the mist size in a chamber of the fluidized bed, in which actual coating is carried out. Therefore, using hydroxypropylmethyl cellulose (HPMC) aqueous solution as a coating solution, the spray mist size of the coating solution in a chamber of the fluidized bed was measured under various coating conditions, such as the distance from the spray nozzle, fluidization air volume, inlet air temperature and addition of sodium chloride (NaCl) into the coating solution. The mist size in the fluidized bed was compared with that in open air at various distances from the spray nozzle. Further, the relationship between the spray mist size and the degree of suppression of agglomeration at various NaCl concentrations during fluidized bed coating was studied. The mist size distribution showed a logarithmic normal distribution in both cases of the fluidized bed and open air. The number-basis median diameter of spray mist (D50) in the fluidized bed was smaller compared with that in open air. D50 increased with the increasing distance from the spray nozzle in both cases. In the fluidized bed, D50 decreased with the increasing fluidization air volume and inlet air temperature. The effect of NaCl concentration on the mist size was hardly observed, but the degree of suppression of agglomeration during coating increased with the increasing NaCl concentration in the coating solution.

  3. Hierarchical structure observation and nanoindentation size effect characterization for a limnetic shell

    NASA Astrophysics Data System (ADS)

    Song, Jingru; Fan, Cuncai; Ma, Hansong; Wei, Yueguang

    2015-06-01

    In the present research, hierarchical structure observation and mechanical property characterization for a type of biomaterial are carried out. The investigated biomaterial is Hyriopsis cumingii, a typical limnetic shell, which consists of two different structural layers, a prismatic "pillar" structure and a nacreous "brick and mortar" structure. The prismatic layer looks like a "pillar forest" with variation-section pillars sized on the order of several tens of microns. The nacreous material looks like a "brick wall" with bricks sized on the order of several microns. Both pillars and bricks are composed of nanoparticles. The mechanical properties of the hierarchical biomaterial are measured by using the nanoindentation test. Hardness and modulus are measured for both the nacre layer and the prismatic layer, respectively. The nanoindentation size effects for the hierarchical structural materials are investigated experimentally. The results show that the prismatic nanostructured material has a higher stiffness and hardness than the nacre nanostructured material. In addition, the nanoindentation size effects for the hierarchical structural materials are described theoretically, by using the trans-scale mechanics theory considering both strain gradient effect and the surface/interface effect. The modeling results are consistent with experimental ones.

  4. Comparison of Quantitative Wall Motion Analysis and Strain For Detection Of Coronary Stenosis With Three-Dimensional Dobutamine Stress Echocardiography

    PubMed Central

    Parker, Katherine M.; Clark, Alexander P.; Goodman, Norman C.; Glover, David K.; Holmes, Jeffrey W.

    2015-01-01

    Background Quantitative analysis of wall motion from three-dimensional (3D) dobutamine stress echocardiography (DSE) could provide additional diagnostic information not available from qualitative analysis. In this study we compare the effectiveness of 3D fractional shortening (3DFS), a measure of wall motion computed from 3D echocardiography (3DE), to strain and strain rate measured with sonomicrometry for detecting critical stenoses during DSE. Methods Eleven open-chest dogs underwent DSE both with and without a critical stenosis. 3DFS was measured from 3DE images acquired at peak stress. 3DFS was normalized by subtracting average 3DFS during control peak stress (Δ3DFS). Strains in the perfusion defect (PD) were measured from sonomicrometry, and PD size and location were measured with microspheres. Results A Δ3DFS abnormality indicated the presence of a critical stenosis with high sensitivity and specificity (88% and 100%, respectively), and Δ3DFS abnormality size correlated with PD size (R2=0.54). The sensitivity and specificity for Δ3DFS was similar to that for area strain (88%, 100%) and circumferential strain and strain rate (88%, 92% and 88%, 86%, respectively), while longitudinal strain and strain rate were less specific. Δ3DFS correlated significantly with both coronary flow reserve (R2=0.71) and PD size (R2=0.97), while area strain correlated with PD size only (R2=0.67), and other measures were not significantly correlated with flow reserve or PD size. Conclusion Quantitative wall motion analysis using Δ3DFS is effective for detecting critical stenoses during DSE, performing similarly to 3D strain, and provides potentially useful information on the size and location of a perfusion defect. PMID:24815588

  5. Size-of-source Effect in Infrared Thermometers with Direct Reading of Temperature

    NASA Astrophysics Data System (ADS)

    Manoi, A.; Saunders, P.

    2017-07-01

    The size-of-source effect (SSE) for six infrared (IR) thermometers with direct reading of temperature was measured in this work. The alternative direct method for SSE determination, where the aperture size is fixed and the measurement distance is varied, was used in this study. The experimental equivalence between the usual and the alternative direct methods is presented. The magnitudes of the SSE for different types of IR thermometers were investigated. The maxima of the SSE were found to be up to 5 %, 8 %, and 28 % for focusable, closed-focus, and open-focus thermometers, respectively. At 275°C, an SSE of 28 % corresponds to 52°C, indicating the severe effect on the accuracy of this type of IR thermometer. A method to realize the calibration conditions used by the manufacturer, in terms of aperture size and measurement distance, is discussed and validated by experimental results. This study would be of benefit to users in choosing the best IR thermometer to match their work and for calibration laboratories in selecting the technique most suitable for determining the SSE.

  6. Can the Lateral Proximity Effect Be Used to Create the Superconducting Transition of a Micron-Sized TES?

    NASA Technical Reports Server (NTRS)

    Barrentine, E. M.; Brandl, D. E.; Brown, A. D.; Denis, K. L.; Fionkbeiner, F. M.; Hsieh, W. T.; Nagler, P. C.; Stevenson, T. R.; Timble, P. T.; U-Yen, K.

    2012-01-01

    Recent measurements of micron-sized Mo/Au bilayer Transition Edge Sensors (TESs) have demonstrated that the TES can behave like an S-S'-S weak link due to the lateral proximity effect from superconducting leads. In this regime the Tc is a function of bias current, and the effective Tc shifts from the bilayer Tc towards the lead Tc. We explore the idea that a micron-sized S-N-S weak link could provide a new method to engineer the TES Tc. This method would be particularly useful when small size requirements for a bilayer TES (such as for a hot-electron microbolometer) lead to undesirable shifts in the bilayer Te. We present measurements of a variety of micron-sized normal Au 'TES' devices with Nb leads. We find no evidence of a superconducting transition in the Au film of these devices, in dramatic contrast to the strong lateral proximity effect seen in micron-sized Mo/Au bilayer devices. The absence of a transition in these devices is also in disagreement with theoretical predictions for S-N-S weak links. We hypothesize that a finite contact resistance between the Nb and Au may be weakening the effect. We conclude that the use of the lateral proximity effect to create a superconducting transition will be difficult given current fabrication procedures.

  7. Determining the effect of grain size and maximum induction upon coercive field of electrical steels

    NASA Astrophysics Data System (ADS)

    Landgraf, Fernando José Gomes; da Silveira, João Ricardo Filipini; Rodrigues-Jr., Daniel

    2011-10-01

    Although theoretical models have already been proposed, experimental data is still lacking to quantify the influence of grain size upon coercivity of electrical steels. Some authors consider a linear inverse proportionality, while others suggest a square root inverse proportionality. Results also differ with regard to the slope of the reciprocal of grain size-coercive field relation for a given material. This paper discusses two aspects of the problem: the maximum induction used for determining coercive force and the possible effect of lurking variables such as the grain size distribution breadth and crystallographic texture. Electrical steel sheets containing 0.7% Si, 0.3% Al and 24 ppm C were cold-rolled and annealed in order to produce different grain sizes (ranging from 20 to 150 μm). Coercive field was measured along the rolling direction and found to depend linearly on reciprocal of grain size with a slope of approximately 0.9 (A/m)mm at 1.0 T induction. A general relation for coercive field as a function of grain size and maximum induction was established, yielding an average absolute error below 4%. Through measurement of B50 and image analysis of micrographs, the effects of crystallographic texture and grain size distribution breadth were qualitatively discussed.

  8. Study of Consumer Automotive Preference with Regard to Fuel Economy Measures

    DOT National Transportation Integrated Search

    1978-09-01

    An analysis is made of the effects of size and weight reduction of 1977 General Motors standard size cars. A buyer profile describing demographic characteristics, age, sex, education, marital status, size of family and income by make is prepared for ...

  9. Opposing Brain Differences in 16p11.2 Deletion and Duplication Carriers

    PubMed Central

    Qureshi, Abid Y.; Mueller, Sophia; Snyder, Abraham Z.; Mukherjee, Pratik; Berman, Jeffrey I.; Roberts, Timothy P.L.; Nagarajan, Srikantan S.; Spiro, John E.; Chung, Wendy K.; Sherr, Elliott H.

    2014-01-01

    Deletions and duplications of the recurrent ∼600 kb chromosomal BP4–BP5 region of 16p11.2 are associated with a broad variety of neurodevelopmental outcomes including autism spectrum disorder. A clue to the pathogenesis of the copy number variant (CNV)'s effect on the brain is that the deletion is associated with a head size increase, whereas the duplication is associated with a decrease. Here we analyzed brain structure in a clinically ascertained group of human deletion (N = 25) and duplication (N = 17) carriers from the Simons Variation in Individuals Project compared with age-matched controls (N = 29 and 33, respectively). Multiple brain measures showed increased size in deletion carriers and reduced size in duplication carriers. The effects spanned global measures of intracranial volume, brain size, compartmental measures of gray matter and white matter, subcortical structures, and the cerebellum. Quantitatively, the largest effect was on the thalamus, but the collective results suggest a pervasive rather than a selective effect on the brain. Detailed analysis of cortical gray matter revealed that cortical surface area displays a strong dose-dependent effect of CNV (deletion > control > duplication), whereas average cortical thickness is less affected. These results suggest that the CNV may exert its opposing influences through mechanisms that influence early stages of embryonic brain development. PMID:25143601

  10. Network characteristics and patent value-Evidence from the Light-Emitting Diode industry.

    PubMed

    Huang, Way-Ren; Hsieh, Chia-Jen; Chang, Ke-Chiun; Kiang, Yen-Jo; Yuan, Chien-Chung; Chu, Woei-Chyn

    2017-01-01

    This study proposes a different angle to social network analysis that evaluates patent value and explores its influencing factors using the network centrality and network position. This study utilizes a logistic regression model to explore the relationships in the LED industry between patent value and network centrality as measured from out-degree centrality, in-degree centrality, in-closeness centrality, and network position, which is measured from effect size. The empirical result shows that out-degree centrality and in-degree centrality have significant positive effects on patent value and that effect size has a significant negative effect on patent value.

  11. Effect of drug load and plate coating on the particle size distribution of a commercial albuterol metered dose inhaler (MDI) determined using the Andersen and Marple-Miller cascade impactors.

    PubMed

    Nasr, M M; Ross, D L; Miller, N C

    1997-10-01

    The purpose of this study is to investigate the effect of drug load, the coating of impactor stages, and the design of cascade impactors on albuterol MDIs particle size distribution measurements. The results of the investigation will be used to explain the "loading effect" recently reported. Particle size distribution parameters of a commercial albuterol MDI were measured using both Andersen (AI) and Marple-Miller (MMI) Cascade Impactors, where plates were either left uncoated or coated with silicone or glycerin. A previously validated HPLC-EC method was used for the assay of albuterol collected by the impactor and in single spray content determinations. Coating impactor collection plates had an impact on measured MMAD and GSD values for single puff measurements but very little or no effect for the multi puff measurements. Due to particle bounce, the percent of albuterol fine particles deposited in the filter and impactor finer stages (< 1.10 microns in AI and < 1.25 microns in MMI) in uncoated single puff experiments was much higher in comparison to either coated single puff or multi-puff (coated and uncoated) measurements. Evaluation of drug load and plate coating are necessary to determine whether observed particle size distributions are representative of the generated aerosol or are the result of particle bounce and reentrainment. In order to minimize particle bounce, especially for single puff determinations, it may be useful to apply a thin layer of a sticky coating agent to the surfaces of impactor plates.

  12. TU-F-CAMPUS-T-04: Variations in Nominally Identical Small Fields From Photon Jaw Reproducibility and Associated Effects On Small Field Dosimetric Parameters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Muir, B R; McEwen, M R

    2015-06-15

    Purpose: To investigate uncertainties in small field output factors and detector specific correction factors from variations in field size for nominally identical fields using measurements and Monte Carlo simulations. Methods: Repeated measurements of small field output factors are made with the Exradin W1 (plastic scintillation detector) and the PTW microDiamond (synthetic diamond detector) in beams from the Elekta Precise linear accelerator. We investigate corrections for a 0.6x0.6 cm{sup 2} nominal field size shaped with secondary photon jaws at 100 cm source to surface distance (SSD). Measurements of small field profiles are made in a water phantom at 10 cm depthmore » using both detectors and are subsequently used for accurate detector positioning. Supplementary Monte Carlo simulations with EGSnrc are used to calculate the absorbed dose to the detector and absorbed dose to water under the same conditions when varying field size. The jaws in the BEAMnrc model of the accelerator are varied by a reasonable amount to investigate the same situation without the influence of measurements uncertainties (such as detector positioning or variation in beam output). Results: For both detectors, small field output factor measurements differ by up to 11 % when repeated measurements are made in nominally identical 0.6x0.6 cm{sup 2} fields. Variations in the FWHM of measured profiles are consistent with field size variations reported by the accelerator. Monte Carlo simulations of the dose to detector vary by up to 16 % under worst case variations in field size. These variations are also present in calculations of absorbed dose to water. However, calculated detector specific correction factors are within 1 % when varying field size because of cancellation of effects. Conclusion: Clinical physicists should be aware of potentially significant uncertainties in measured output factors required for dosimetry of small fields due to field size variations for nominally identical fields.« less

  13. Influence of test capacitor features on piezoelectric and dielectric measurement of ferroelectric films.

    PubMed

    Wang, Zhihong; Lau, Gih Keong; Zhu, Weiguang; Chao, Chen

    2006-01-01

    This paper presents both theoretical and numerical analyses of the piezoelectric and dielectric responses of a highly idealized film-on-substrate system, namely, a polarized ferroelectric film perfectly bonded to an elastic silicon substrate. It shows that both effective dielectric and piezoelectric properties of the films change with the size and configuration of the test capacitor. There exists a critical electrode size that is smaller than the diameter of the commonly used substrate. The effective film properties converge to their respective constrained values as capacitor size increases to the critical size. If capacitor size is smaller than the critical size, the surface displacement at the top electrode deviates from the net thickness change in response to an applied voltage because the film is deformable at the film/substrate interface. The constrained properties of the films depend only on those of bulk ferroelectrics but are independent of film thickness and substrate properties. The finding of the critical capacitor size together with analytical expressions of the constrained properties makes it possible to realize consistent measurement of piezoelectric and dielectric properties of films. A surface scanning technique is recommended to measure the profile of piezoresponses of the film so that the constrained properties of the film can be identified accurately.

  14. Sample size requirements for estimating effective dose from computed tomography using solid-state metal-oxide-semiconductor field-effect transistor dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Trattner, Sigal; Cheng, Bin; Pieniazek, Radoslaw L.

    2014-04-15

    Purpose: Effective dose (ED) is a widely used metric for comparing ionizing radiation burden between different imaging modalities, scanners, and scan protocols. In computed tomography (CT), ED can be estimated by performing scans on an anthropomorphic phantom in which metal-oxide-semiconductor field-effect transistor (MOSFET) solid-state dosimeters have been placed to enable organ dose measurements. Here a statistical framework is established to determine the sample size (number of scans) needed for estimating ED to a desired precision and confidence, for a particular scanner and scan protocol, subject to practical limitations. Methods: The statistical scheme involves solving equations which minimize the sample sizemore » required for estimating ED to desired precision and confidence. It is subject to a constrained variation of the estimated ED and solved using the Lagrange multiplier method. The scheme incorporates measurement variation introduced both by MOSFET calibration, and by variation in MOSFET readings between repeated CT scans. Sample size requirements are illustrated on cardiac, chest, and abdomen–pelvis CT scans performed on a 320-row scanner and chest CT performed on a 16-row scanner. Results: Sample sizes for estimating ED vary considerably between scanners and protocols. Sample size increases as the required precision or confidence is higher and also as the anticipated ED is lower. For example, for a helical chest protocol, for 95% confidence and 5% precision for the ED, 30 measurements are required on the 320-row scanner and 11 on the 16-row scanner when the anticipated ED is 4 mSv; these sample sizes are 5 and 2, respectively, when the anticipated ED is 10 mSv. Conclusions: Applying the suggested scheme, it was found that even at modest sample sizes, it is feasible to estimate ED with high precision and a high degree of confidence. As CT technology develops enabling ED to be lowered, more MOSFET measurements are needed to estimate ED with the same precision and confidence.« less

  15. The Effect of Brain Based Learning on Academic Achievement: A Meta-Analytical Study

    ERIC Educational Resources Information Center

    Gozuyesil, Eda; Dikici, Ayhan

    2014-01-01

    This study's aim is to measure the effect sizes of the quantitative studies that examined the effectiveness of brain-based learning on students' academic achievement and to examine with the meta-analytical method if there is a significant difference in effect in terms of the factors of education level, subject matter, sampling size, and the…

  16. Body size and allometric variation in facial shape in children.

    PubMed

    Larson, Jacinda R; Manyama, Mange F; Cole, Joanne B; Gonzalez, Paula N; Percival, Christopher J; Liberton, Denise K; Ferrara, Tracey M; Riccardi, Sheri L; Kimwaga, Emmanuel A; Mathayo, Joshua; Spitzmacher, Jared A; Rolian, Campbell; Jamniczky, Heather A; Weinberg, Seth M; Roseman, Charles C; Klein, Ophir; Lukowiak, Ken; Spritz, Richard A; Hallgrimsson, Benedikt

    2018-02-01

    Morphological integration, or the tendency for covariation, is commonly seen in complex traits such as the human face. The effects of growth on shape, or allometry, represent a ubiquitous but poorly understood axis of integration. We address the question of to what extent age and measures of size converge on a single pattern of allometry for human facial shape. Our study is based on two large cross-sectional cohorts of children, one from Tanzania and the other from the United States (N = 7,173). We employ 3D facial imaging and geometric morphometrics to relate facial shape to age and anthropometric measures. The two populations differ significantly in facial shape, but the magnitude of this difference is small relative to the variation within each group. Allometric variation for facial shape is similar in both populations, representing a small but significant proportion of total variation in facial shape. Different measures of size are associated with overlapping but statistically distinct aspects of shape variation. Only half of the size-related variation in facial shape can be explained by the first principal component of four size measures and age while the remainder associates distinctly with individual measures. Allometric variation in the human face is complex and should not be regarded as a singular effect. This finding has important implications for how size is treated in studies of human facial shape and for the developmental basis for allometric variation more generally. © 2017 Wiley Periodicals, Inc.

  17. Simulation and measurement of nanometer-scale resistivity of copper films for interconnect applications

    NASA Astrophysics Data System (ADS)

    Yarimbiyik, Arif Emre

    2007-12-01

    A highly versatile simulation program is developed and used to examine how the resistivity of thin metal films and lines increases as their dimensions approach and become smaller than the mean fee path of electrons in metals such as copper (size effect). The simulation program: (1) provides a more accurate calculation of surface scattering effects than that obtained from the usual formulation of Fuchs' theory, (2) calculates grain-boundary effects that are consistent with the theory of Mayadas and Shatzkes, (3) includes the effects of surface and grain-boundary scattering either separately or together, and (4) simulates the effect on resistivity if a surface of a film or line has a different value for the scattering parameter. The increase in resistivity with decreasing thickness of thin, evaporated copper films (approximately 10 nm to 150 nm thick) was determined from sheet resistance and film thickness measurements. Good agreement between the experimental results with those of the simulation program was obtained when the measured mean grain sizes were used by the simulation program. The mean of the grain sizes tend to decrease with decreasing film thickness and thereby increase the impact of grain-boundary scattering on the effective resistivity of the film. Estimates of the mean grain size for each film were determined from using, in combination, the electron backscatter diffraction (EBSD) and the X-ray diffraction (XRD) methods. With values for the measured change in sheet resistance with temperature of these films, it is shown that measurements of the electrical film thickness, using Matthiessen's rule, agreed to within 3 nm of the physical measurements (profilometer) of these films. Hence, Matthiessen's rule can continue to be used to measure the thickness of a copper film and, by inference, the cross-sectional area of a copper line for dimensions well below the mean free path of electrons in copper at room temperature (39 nm).

  18. Measured particulate behavior in a subscale solid propellant rocket motor

    NASA Astrophysics Data System (ADS)

    Brennan, W. D.; Hovland, D. L.; Netzer, D. W.

    1992-10-01

    Particulate matter are sized in the exhaust nozzle and plume of small rocket motors of varying geometry to assess the effects of the expansion process on particle size. Both converging and converging-diverging nozzles are considered, and particle sizing is accomplished at pressures of up to 4.36 MPa with aluminum loadings of 2.0 and 4.7 percent. An instrument based on Fraunhofer diffraction is used to measure the particle-size distributions showing that: (1) high burning rates reduce particle agglomeration and increase C* efficiency; (2) high pressures lead to small and monomodal D32 entering the nozzle; and (3) D32 sizes increase appreciably at the tailoff. Some variations in plume signature are theorized to be caused by the tailoff phenomenon, and particle collisions and/or surface effects in the nozzle convergence are suggested by the reduced number of larger particles at the nozzle convergence.

  19. The large sample size fallacy.

    PubMed

    Lantz, Björn

    2013-06-01

    Significance in the statistical sense has little to do with significance in the common practical sense. Statistical significance is a necessary but not a sufficient condition for practical significance. Hence, results that are extremely statistically significant may be highly nonsignificant in practice. The degree of practical significance is generally determined by the size of the observed effect, not the p-value. The results of studies based on large samples are often characterized by extreme statistical significance despite small or even trivial effect sizes. Interpreting such results as significant in practice without further analysis is referred to as the large sample size fallacy in this article. The aim of this article is to explore the relevance of the large sample size fallacy in contemporary nursing research. Relatively few nursing articles display explicit measures of observed effect sizes or include a qualitative discussion of observed effect sizes. Statistical significance is often treated as an end in itself. Effect sizes should generally be calculated and presented along with p-values for statistically significant results, and observed effect sizes should be discussed qualitatively through direct and explicit comparisons with the effects in related literature. © 2012 Nordic College of Caring Science.

  20. The Effect of Superior Semicircular Canal Dehiscence on Intracochlear Sound Pressures

    NASA Astrophysics Data System (ADS)

    Nakajima, Hideko Heidi; Pisano, Dominic V.; Merchant, Saumil N.; Rosowski, John J.

    2011-11-01

    Semicircular canal dehiscence (SCD) is a pathological opening in the bony wall of the inner ear that can result in conductive hearing loss. The hearing loss is variable across patients, and the precise mechanism and source of variability is not fully understood. We use intracochlear sound pressure measurements in cadaveric preparations to study the effects of SCD size. Simultaneous measurement of basal intracochlear sound pressures in scala vestibuli (SV) and scala tympani (ST) quantifies the complex differential pressure across the cochlear partition, the stimulus that excites the partition. Sound-induced pressures in SV and ST, as well as stapes velocity and ear-canal pressure are measured simultaneously for various sizes of SCD followed by SCD patching. At low frequencies (<600 Hz) our results show that SCD decreases the pressure in both SV and ST, as well as differential pressure, and these effects become more pronounced as dehiscence size is increased. For frequencies above 1 kHz, the smallest pinpoint dehiscence can have the larger effect on the differential pressure in some ears. These effects due to SCD are reversible by patching the dehiscence.

  1. Bias Corrections for Standardized Effect Size Estimates Used with Single-Subject Experimental Designs

    ERIC Educational Resources Information Center

    Ugille, Maaike; Moeyaert, Mariola; Beretvas, S. Natasha; Ferron, John M.; Van den Noortgate, Wim

    2014-01-01

    A multilevel meta-analysis can combine the results of several single-subject experimental design studies. However, the estimated effects are biased if the effect sizes are standardized and the number of measurement occasions is small. In this study, the authors investigated 4 approaches to correct for this bias. First, the standardized effect…

  2. Undersampling power-law size distributions: effect on the assessment of extreme natural hazards

    USGS Publications Warehouse

    Geist, Eric L.; Parsons, Thomas E.

    2014-01-01

    The effect of undersampling on estimating the size of extreme natural hazards from historical data is examined. Tests using synthetic catalogs indicate that the tail of an empirical size distribution sampled from a pure Pareto probability distribution can range from having one-to-several unusually large events to appearing depleted, relative to the parent distribution. Both of these effects are artifacts caused by limited catalog length. It is more difficult to diagnose the artificially depleted empirical distributions, since one expects that a pure Pareto distribution is physically limited in some way. Using maximum likelihood methods and the method of moments, we estimate the power-law exponent and the corner size parameter of tapered Pareto distributions for several natural hazard examples: tsunamis, floods, and earthquakes. Each of these examples has varying catalog lengths and measurement thresholds, relative to the largest event sizes. In many cases where there are only several orders of magnitude between the measurement threshold and the largest events, joint two-parameter estimation techniques are necessary to account for estimation dependence between the power-law scaling exponent and the corner size parameter. Results indicate that whereas the corner size parameter of a tapered Pareto distribution can be estimated, its upper confidence bound cannot be determined and the estimate itself is often unstable with time. Correspondingly, one cannot statistically reject a pure Pareto null hypothesis using natural hazard catalog data. Although physical limits to the hazard source size and by attenuation mechanisms from source to site constrain the maximum hazard size, historical data alone often cannot reliably determine the corner size parameter. Probabilistic assessments incorporating theoretical constraints on source size and propagation effects are preferred over deterministic assessments of extreme natural hazards based on historic data.

  3. Contact behavior modelling and its size effect on proton exchange membrane fuel cell

    NASA Astrophysics Data System (ADS)

    Qiu, Diankai; Peng, Linfa; Yi, Peiyun; Lai, Xinmin; Janßen, Holger; Lehnert, Werner

    2017-10-01

    Contact behavior between the gas diffusion layer (GDL) and bipolar plate (BPP) is of significant importance for proton exchange membrane fuel cells. Most current studies on contact behavior utilize experiments and finite element modelling and focus on fuel cells with graphite BPPs, which lead to high costs and huge computational requirements. The objective of this work is to build a more effective analytical method for contact behavior in fuel cells and investigate the size effect resulting from configuration alteration of channel and rib (channel/rib). Firstly, a mathematical description of channel/rib geometry is outlined in accordance with the fabrication of metallic BPP. Based on the interface deformation characteristic and Winkler surface model, contact pressure between BPP and GDL is then calculated to predict contact resistance and GDL porosity as evaluative parameters of contact behavior. Then, experiments on BPP fabrication and contact resistance measurement are conducted to validate the model. The measured results demonstrate an obvious dependence on channel/rib size. Feasibility of the model used in graphite fuel cells is also discussed. Finally, size factor is proposed for evaluating the rule of size effect. Significant increase occurs in contact resistance and porosity for higher size factor, in which channel/rib width decrease.

  4. The Density of Mid-sized Kuiper Belt Objects from ALMA Thermal Observations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Michael E.; Butler, Bryan J.

    The densities of mid-sized Kuiper Belt objects (KBOs) are a key constraint in understanding the assembly of objects in the outer solar system. These objects are critical for understanding the currently unexplained transition from the smallest KBOs with densities lower than that of water, to the largest objects with significant rock content. Mapping this transition is made difficult by the uncertainties in the diameters of these objects, which maps into an even larger uncertainty in volume and thus density. The substantial collecting area of the Atacama Large Millimeter Array allows significantly more precise measurements of thermal emission from outer solarmore » system objects and could potentially greatly improve the density measurements. Here we use new thermal observations of four objects with satellites to explore the improvements possible with millimeter data. We find that effects due to effective emissivity at millimeter wavelengths make it difficult to use the millimeter data directly to find diameters and thus volumes for these bodies. In addition, we find that when including the effects of model uncertainty, the true uncertainties on the sizes of outer solar system objects measured with radiometry are likely larger than those previously published. Substantial improvement in object sizes will likely require precise occultation measurements.« less

  5. Fluids and their Effect on Measurements on Lunar Soil Particle size Distribution

    NASA Technical Reports Server (NTRS)

    Cooper, B. L.; McKay, D. S.; Wallace, W. T.; Gonzalex, C. P.

    2011-01-01

    From the late 1960s until now, lunar soil particle size distributions have typically been determined by sieving sometimes dry, and at other times with fluids such as water or Freon. Laser diffraction instruments allow rapid assessment of particle size distribution, and eventually may replace sieve measurements. However, when measuring lunar soils with laser diffraction instruments, care must be taken in choosing a carrier fluid that is compatible with lunar material. Distilled water is the fluid of choice for laser diffraction measurements of substances when there is no concern about adverse effects of water on the material being measured. When we began our analyses of lunar soils using laser diffraction, our first measurements were made with distilled water. Although the medians that we measured were comparable to earlier sieve data, the means tended to be significantly larger than expected. The effect of water vapor on lunar soil has been studied extensively. The particles interact strongly with water vapor, and subsequent adsorptions of nitrogen showed that the specific surface area increased as much as threefold after exposure to moisture. It was observed that significant porosity had been generated by this exposure to water vapor. The possibility of other physical changes in the surfaces of the grains was not studied.

  6. β-alanine supplementation to improve exercise capacity and performance: a systematic review and meta-analysis.

    PubMed

    Saunders, Bryan; Elliott-Sale, Kirsty; Artioli, Guilherme G; Swinton, Paul A; Dolan, Eimear; Roschel, Hamilton; Sale, Craig; Gualano, Bruno

    2017-04-01

    To conduct a systematic review and meta-analysis of the evidence on the effects of β-alanine supplementation on exercise capacity and performance. This study was designed in accordance with PRISMA guidelines. A 3-level mixed effects model was employed to model effect sizes and account for dependencies within data. 3 databases (PubMed, Google Scholar, Web of Science) were searched using a number of terms ('β-alanine' and 'Beta-alanine' combined with 'supplementation', 'exercise', 'training', 'athlete', 'performance' and 'carnosine'). Inclusion/exclusion criteria limited articles to double-blinded, placebo-controlled studies investigating the effects of β-alanine supplementation on an exercise measure. All healthy participant populations were considered, while supplementation protocols were restricted to chronic ingestion. Cross-over designs were excluded due to the long washout period for skeletal muscle carnosine following supplementation. A single outcome measure was extracted for each exercise protocol and converted to effect sizes for meta-analyses. 40 individual studies employing 65 different exercise protocols and totalling 70 exercise measures in 1461 participants were included in the analyses. A significant overall effect size of 0.18 (95% CI 0.08 to 0.28) was shown. Meta-regression demonstrated that exercise duration significantly (p=0.004) moderated effect sizes. Subgroup analyses also identified the type of exercise as a significant (p=0.013) moderator of effect sizes within an exercise time frame of 0.5-10 min with greater effect sizes for exercise capacity (0.4998 (95% CI 0.246 to 0.753)) versus performance (0.1078 (95% CI -0.201 to 0.416)). There was no moderating effect of training status (p=0.559), intermittent or continuous exercise (p=0.436) or total amount of β-alanine ingested (p=0.438). Co-supplementation with sodium bicarbonate resulted in the largest effect size when compared with placebo (0.43 (95% CI 0.22 to 0.64)). β-alanine had a significant overall effect while subgroup analyses revealed a number of modifying factors. These data allow individuals to make informed decisions as to the likelihood of an ergogenic effect with β-alanine supplementation based on their chosen exercise modality. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Weighing the potential effectiveness of various treatments for sleep bruxism.

    PubMed

    Huynh, Nelly; Manzini, Christiane; Rompré, Pierre H; Lavigne, Gilles J

    2007-10-01

    Sleep bruxism may lead to a variety of problems, but its pathophysiology has not been completely elucidated. As such, there is no definitive treatment, but certain preventive measures and/or drugs may be used in acute cases, particularly those involving pain. This article is intended to guide clinician scientists to the treatment most appropriate for future clinical studies. To determine the best current treatment, 2 measures were used to compare the results of 10 clinical studies on sleep bruxism, 3 involving oral devices and 7 involving pharmacologic therapy. The first measure, the number needed to treat (NNT), allows several randomized clinical studies to be compared and a general conclusion to be drawn. The second measure, effect size, allows evaluation of the impact of treatment relative to a placebo using different studies of similar design. Taking into account the NNT, the effect size and the power of each study, it can be concluded that the following treatments reduce sleep bruxism: mandibular advancement device, clonidine and occlusal splint. However, the first 2 of these have been linked to adverse effects. The occlusal splint is therefore the treatment of choice, as it reduces grinding noise and protects the teeth from premature wear with no reported adverse effects. The NNT could not be calculated for an alternative pharmacologic treatment, short-term clonazepam therapy, which had a large effect size and reduced the average bruxism index. However, the risk of dependency limits its use over long periods. Assessment of efficacy and safety of the most promising treatments will require studies with larger sample sizes over longer periods.

  8. The role of retinal versus perceived size in the effects of pitched displays on visually perceived eye level

    NASA Technical Reports Server (NTRS)

    Post, R. B.; Welch, R. B.

    1996-01-01

    Visually perceived eye level (VPEL) was measured while subjects viewed two vertical lines which were either upright or pitched about the horizontal axis. In separate conditions, the display consisted of a relatively large pair of lines viewed at a distance of 1 m, or a display scaled to one third the dimensions and viewed at a distance of either 1 m or 33.3 cm. The small display viewed at 33.3 cm produced a retinal image the same size as that of the large display at 1 m. Pitch of all three displays top-toward and top-away from the observer caused upward and downward VPEL shifts, respectively. These effects were highly similar for the large display and the small display viewed at 33.3 cm (ie equal retinal size), but were significantly smaller for the small display viewed at 1 m. In a second experiment, perceived size of the three displays was measured and found to be highly accurate. The results of the two experiments indicate that the effect of optical pitch on VPEL depends on the retinal image size of stimuli rather than on perceived size.

  9. 3D-HST + CANDELS: the Evolution of the Galaxy Size-mass Distribution Since Z=3

    NASA Technical Reports Server (NTRS)

    VanDerWel, A.; Franx, M.; vanDokkum, P. G.; Skelton, R. E.; Momcheva, I. G.; Whitaker, K. E.; Brammer, G. B.; Bell, E. F.; Rix, H.-W.; Wuyts, S.; hide

    2014-01-01

    Spectroscopic and photometric redshifts, stellar mass estimates, and rest-frame colors from the 3D-HST survey are combined with structural parameter measurements from CANDELS imaging to determine the galaxy size-mass distribution over the redshift (z) range 0 < z < 3. Separating early- and late-type galaxies on the basis of star-formation activity, we confirm that early-type galaxies are on average smaller than late-type galaxies at all redshifts, and find a significantly different rate of average size evolution at fixed galaxy mass, with fast evolution for the early-type population, effective radius is in proportion to (1 + z) (sup -1.48), and moderate evolution for the late-type population, effective radius is in proportion to (1 + z) (sup -0.75). The large sample size and dynamic range in both galaxy mass and redshift, in combination with the high fidelity of our measurements due to the extensive use of spectroscopic data, not only fortify previous results, but also enable us to probe beyond simple average galaxy size measurements. At all redshifts the slope of the size-mass relation is shallow, effective radius in proportion to mass of a black hole (sup 0.22), for late-type galaxies with stellar mass > 3 x 10 (sup 9) solar masses, and steep, effective radius in proportion to mass of a black hole (sup 0.75), for early-type galaxies with stellar mass > 2 x 10 (sup 10) solar masses. The intrinsic scatter is approximately or less than 0.2 decimal exponents for all galaxy types and redshifts. For late-type galaxies, the logarithmic size distribution is not symmetric, but skewed toward small sizes: at all redshifts and masses a tail of small late-type galaxies exists that overlaps in size with the early-type galaxy population. The number density of massive (approximately 10 (sup 11) solar masses), compact (effective radius less than 2 kiloparsecs) early-type galaxies increases from z = 3 to z = 1.5 - 2 and then strongly decreases at later cosmic times.

  10. Micrometer-scale particle sizing by laser diffraction: critical impact of the imaginary component of refractive index.

    PubMed

    Beekman, Alice; Shan, Daxian; Ali, Alana; Dai, Weiguo; Ward-Smith, Stephen; Goldenberg, Merrill

    2005-04-01

    This study evaluated the effect of the imaginary component of the refractive index on laser diffraction particle size data for pharmaceutical samples. Excipient particles 1-5 microm in diameter (irregular morphology) were measured by laser diffraction. Optical parameters were obtained and verified based on comparison of calculated vs. actual particle volume fraction. Inappropriate imaginary components of the refractive index can lead to inaccurate results, including false peaks in the size distribution. For laser diffraction measurements, obtaining appropriate or "effective" imaginary components of the refractive index was not always straightforward. When the recommended criteria such as the concentration match and the fit of the scattering data gave similar results for very different calculated size distributions, a supplemental technique, microscopy with image analysis, was used to decide between the alternatives. Use of effective optical parameters produced a good match between laser diffraction data and microscopy/image analysis data. The imaginary component of the refractive index can have a major impact on particle size results calculated from laser diffraction data. When performed properly, laser diffraction and microscopy with image analysis can yield comparable results.

  11. Food environments and dietary intakes among adults: does the type of spatial exposure measurement matter? A systematic review.

    PubMed

    Bivoltsis, Alexia; Cervigni, Eleanor; Trapp, Gina; Knuiman, Matthew; Hooper, Paula; Ambrosini, Gina Leslie

    2018-06-09

    The relationships between food environments and dietary intake have been assessed via a range of methodologically diverse measures of spatial exposure to food outlets, resulting in a largely inconclusive body of evidence, limiting informed policy intervention. This systematic review aims to evaluate the influence of methodological choice on study outcomes by examining the within-study effect of availability (e.g., counts) versus accessibility (e.g., proximity) spatial exposure measures on associations with diet. (PROSPERO registration: CRD42018085250). PubMed, Web of Science, Scopus and ScienceDirect databases were searched for empirical studies from 1980 to 2017, in the English language, involving adults and reporting on the statistical association between a dietary outcome and spatial exposure measures of both availability and accessibility. Studies were appraised using an eight-point quality criteria with a narrative synthesis of results. A total of 205 associations and 44 relationships (i.e., multiple measures of spatial exposure relating to a particular food outlet type and dietary outcome) were extracted from 14 eligible articles. Comparative measures were dominated by counts (availability) and proximity (accessibility). Few studies compared more complex measures and all counts were derived from place-based measures of exposure. Sixteen of the 44 relationships had a significant effect involving an availability measure whilst only 8 had a significant effect from an accessibility measure. The largest effect sizes in relationships were mostly for availability measures. After stratification by scale, availability measure had the greatest effect size in 139 of the 176 pairwise comparisons. Of the 33% (68/205) of associations that reached significance, 53/68 (78%) were from availability measures. There was no relationship between study quality and reported study outcomes. The limited evidence suggests that availability measures may produce significant and greater effect sizes than accessibility measures. However, both availability and accessibility measures may be important concepts of spatial exposure depending on the food outlet type and dietary outcome examined. More studies reporting on multi-method effects are required to differentiate findings by the type of spatial exposure assessment and build an evidence base regarding the appropriateness and robustness of measures under different circumstances.

  12. Comparison of sprinkler droplet size and velocity measurements using a laser precipitation meter and photographic method

    USDA-ARS?s Scientific Manuscript database

    Kinetic energy of water droplets has a substantial effect on development of a soil surface seal and infiltration rate of bare soil. Methods for measuring sprinkler droplet size and velocity needed to calculate droplet kinetic energy have been developed and tested over the past 50 years, each with ad...

  13. In Situ Balloon-Borne Ice Particle Imaging in High-Latitude Cirrus

    NASA Astrophysics Data System (ADS)

    Kuhn, Thomas; Heymsfield, Andrew J.

    2016-09-01

    Cirrus clouds reflect incoming solar radiation, creating a cooling effect. At the same time, these clouds absorb the infrared radiation from the Earth, creating a greenhouse effect. The net effect, crucial for radiative transfer, depends on the cirrus microphysical properties, such as particle size distributions and particle shapes. Knowledge of these cloud properties is also needed for calibrating and validating passive and active remote sensors. Ice particles of sizes below 100 µm are inherently difficult to measure with aircraft-mounted probes due to issues with resolution, sizing, and size-dependent sampling volume. Furthermore, artefacts are produced by shattering of particles on the leading surfaces of the aircraft probes when particles several hundred microns or larger are present. Here, we report on a series of balloon-borne in situ measurements that were carried out at a high-latitude location, Kiruna in northern Sweden (68N 21E). The method used here avoids these issues experienced with the aircraft probes. Furthermore, with a balloon-borne instrument, data are collected as vertical profiles, more useful for calibrating or evaluating remote sensing measurements than data collected along horizontal traverses. Particles are collected on an oil-coated film at a sampling speed given directly by the ascending rate of the balloon, 4 m s-1. The collecting film is advanced uniformly inside the instrument so that an always unused section of the film is exposed to ice particles, which are measured by imaging shortly after sampling. The high optical resolution of about 4 µm together with a pixel resolution of 1.65 µm allows particle detection at sizes of 10 µm and larger. For particles that are 20 µm (12 pixel) in size or larger, the shape can be recognized. The sampling volume, 130 cm3 s-1, is well defined and independent of particle size. With the encountered number concentrations of between 4 and 400 L-1, this required about 90- to 4-s sampling times to determine particle size distributions of cloud layers. Depending on how ice particles vary through the cloud, several layers per cloud with relatively uniform properties have been analysed. Preliminary results of the balloon campaign, targeting upper tropospheric, cold cirrus clouds, are presented here. Ice particles in these clouds were predominantly very small, with a median size of measured particles of around 50 µm and about 80 % of all particles below 100 µm in size. The properties of the particle size distributions at temperatures between -36 and -67 °C have been studied, as well as particle areas, extinction coefficients, and their shapes (area ratios). Gamma and log-normal distribution functions could be fitted to all measured particle size distributions achieving very good correlation with coefficients R of up to 0.95. Each distribution features one distinct mode. With decreasing temperature, the mode diameter decreases exponentially, whereas the total number concentration increases by two orders of magnitude with decreasing temperature in the same range. The high concentrations at cold temperatures also caused larger extinction coefficients, directly determined from cross-sectional areas of single ice particles, than at warmer temperatures. The mass of particles has been estimated from area and size. Ice water content (IWC) and effective diameters are then determined from the data. IWC did vary only between 1 × 10-3 and 5 × 10-3 g m-3 at temperatures below -40 °C and did not show a clear temperature trend. These measurements are part of an ongoing study.

  14. A meta-analysis on the relationship between self-reported presence and anxiety in virtual reality exposure therapy for anxiety disorders.

    PubMed

    Ling, Yun; Nefs, Harold T; Morina, Nexhmedin; Heynderickx, Ingrid; Brinkman, Willem-Paul

    2014-01-01

    In virtual reality exposure therapy (VRET) for anxiety disorders, sense of presence in the virtual environment is considered the principal mechanism that enables anxiety to be felt. Existing studies on the relation between sense of presence and level of anxiety, however, have yielded mixed results on the correlation between the two. In this meta-analysis, we reviewed publications on VRET for anxiety that included self-reported presence and anxiety. The comprehensive search of the literature identified 33 publications with a total of 1196 participants. The correlation between self-reported sense of presence and anxiety was extracted and meta-analyzed. Potential moderators such as technology characteristics, sample characteristics including age, gender and clinical status, disorder characteristics and study design characteristics such as measurements were also examined. The random effects analysis showed a medium effect size for the correlation between sense of presence and anxiety (r = .28; 95% CI: 0.18-0.38). Moderation analyses revealed that the effect size of the correlation differed across different anxiety disorders, with a large effect size for fear of animals (r = .50; 95% CI: 0.30-0.66) and a no to small effect size for social anxiety disorder (r = .001; 95% CI: -0.19-0.19). Further, the correlation between anxiety and presence was stronger in studies with participants who met criteria for an anxiety disorder than in studies with a non-clinical population. Trackers with six degrees of freedom and displays with a larger field of view resulted in higher effect sizes, compared to trackers with three degrees of freedom and displays with a smaller field of view. In addition, no difference in effect size was found for the type of presence measurement and the type of anxiety measurement. This meta-analysis confirms the positive relation between sense of presence and anxiety and demonstrates that this relation can be affected by various moderating factors.

  15. A Meta-Analysis on the Relationship between Self-Reported Presence and Anxiety in Virtual Reality Exposure Therapy for Anxiety Disorders

    PubMed Central

    Ling, Yun; Nefs, Harold T.; Morina, Nexhmedin; Heynderickx, Ingrid; Brinkman, Willem-Paul

    2014-01-01

    In virtual reality exposure therapy (VRET) for anxiety disorders, sense of presence in the virtual environment is considered the principal mechanism that enables anxiety to be felt. Existing studies on the relation between sense of presence and level of anxiety, however, have yielded mixed results on the correlation between the two. In this meta-analysis, we reviewed publications on VRET for anxiety that included self-reported presence and anxiety. The comprehensive search of the literature identified 33 publications with a total of 1196 participants. The correlation between self-reported sense of presence and anxiety was extracted and meta-analyzed. Potential moderators such as technology characteristics, sample characteristics including age, gender and clinical status, disorder characteristics and study design characteristics such as measurements were also examined. The random effects analysis showed a medium effect size for the correlation between sense of presence and anxiety (r = .28; 95% CI: 0.18–0.38). Moderation analyses revealed that the effect size of the correlation differed across different anxiety disorders, with a large effect size for fear of animals (r = .50; 95% CI: 0.30–0.66) and a no to small effect size for social anxiety disorder (r = .001; 95% CI: −0.19–0.19). Further, the correlation between anxiety and presence was stronger in studies with participants who met criteria for an anxiety disorder than in studies with a non-clinical population. Trackers with six degrees of freedom and displays with a larger field of view resulted in higher effect sizes, compared to trackers with three degrees of freedom and displays with a smaller field of view. In addition, no difference in effect size was found for the type of presence measurement and the type of anxiety measurement. This meta-analysis confirms the positive relation between sense of presence and anxiety and demonstrates that this relation can be affected by various moderating factors. PMID:24801324

  16. Clinical study using novel endoscopic system for measuring size of gastrointestinal lesion

    PubMed Central

    Oka, Kiyoshi; Seki, Takeshi; Akatsu, Tomohiro; Wakabayashi, Takao; Inui, Kazuo; Yoshino, Junji

    2014-01-01

    AIM: To verify the performance of a lesion size measurement system through a clinical study. METHODS: Our proposed system, which consists of a conventional endoscope, an optical device, an optical probe, and a personal computer, generates a grid scale to measure the lesion size from an endoscopic image. The width of the grid scale is constantly adjusted according to the distance between the tip of the endoscope and lesion because the lesion size on an endoscopic image changes according to the distance. The shape of the grid scale was corrected to match the distortion of the endoscopic image. The distance was calculated using the amount of laser light reflected from the lesion through an optical probe inserted into the instrument channel of the endoscope. The endoscopist can thus measure the lesion size without contact by comparing the lesion with the size of the grid scale on the endoscopic image. (1) A basic test was performed to verify the relationship between the measurement error eM and the tilt angle of the endoscope; and (2) The sizes of three colon polyps were measured using our system during endoscopy. These sizes were immediately measured by scale after their removal. RESULTS: There was no error at α = 0°. In addition, the values of eM (mean ± SD) were 0.24 ± 0.11 mm (α = 10°), 0.90 ± 0.58 mm (α = 20°) and 2.31 ± 1.41 mm (α = 30°). According to these results, our system has been confirmed to measure accurately when the tilt angle is less than 20°. The measurement error was approximately 1 mm in the clinical study. Therefore, it was concluded that our proposed measurement system was also effective in clinical examinations. CONCLUSION: By combining simple optical equipment with a conventional endoscope, a quick and accurate system for measuring lesion size was established. PMID:24744595

  17. Finite element and analytical solutions for van der Pauw and four-point probe correction factors when multiple non-ideal measurement conditions coexist

    NASA Astrophysics Data System (ADS)

    Reveil, Mardochee; Sorg, Victoria C.; Cheng, Emily R.; Ezzyat, Taha; Clancy, Paulette; Thompson, Michael O.

    2017-09-01

    This paper presents an extensive collection of calculated correction factors that account for the combined effects of a wide range of non-ideal conditions often encountered in realistic four-point probe and van der Pauw experiments. In this context, "non-ideal conditions" refer to conditions that deviate from the assumptions on sample and probe characteristics made in the development of these two techniques. We examine the combined effects of contact size and sample thickness on van der Pauw measurements. In the four-point probe configuration, we examine the combined effects of varying the sample's lateral dimensions, probe placement, and sample thickness. We derive an analytical expression to calculate correction factors that account, simultaneously, for finite sample size and asymmetric probe placement in four-point probe experiments. We provide experimental validation of the analytical solution via four-point probe measurements on a thin film rectangular sample with arbitrary probe placement. The finite sample size effect is very significant in four-point probe measurements (especially for a narrow sample) and asymmetric probe placement only worsens such effects. The contribution of conduction in multilayer samples is also studied and found to be substantial; hence, we provide a map of the necessary correction factors. This library of correction factors will enable the design of resistivity measurements with improved accuracy and reproducibility over a wide range of experimental conditions.

  18. Responsiveness of the EQ-5D to the effects of low vision rehabilitation.

    PubMed

    Malkin, Alexis G; Goldstein, Judith E; Perlmutter, Monica S; Massof, Robert W

    2013-08-01

    This study is an evaluation of the responsiveness of preference-based outcome measures to the effects of low vision rehabilitation (LVR). It assesses LVR-related changes in EQ-5D utilities in patients who exhibit changes in Activity Inventory (AI) measures of visual ability. Telephone interviews were conducted on 77 low-vision patients out of a total of 764 patients in the parent study of "usual care" in LVR. Activity Inventory results were filtered for each patient to include only goals and tasks that would be targeted by LVR. The EQ-5D utilities have weak correlations with all AI measures but correlate best with AI goal scores at baseline (r = 0.48). Baseline goal scores are approximately normally distributed for the AI, but EQ-5D utilities at baseline are skewed toward the ceiling (median, 0.77). Effect size for EQ-5D utility change scores from pre- to post-LVR was not significantly different from zero. The AI visual function ability change scores corresponded to a moderate effect size for all functional domains and a large effect size for visual ability measures estimated from AI goal ratings. This study found that the EQ-5D is unresponsive as an outcome measure for LVR and has poor sensitivity for discriminating low vision patients with different levels of ability.

  19. Finite element and analytical solutions for van der Pauw and four-point probe correction factors when multiple non-ideal measurement conditions coexist.

    PubMed

    Reveil, Mardochee; Sorg, Victoria C; Cheng, Emily R; Ezzyat, Taha; Clancy, Paulette; Thompson, Michael O

    2017-09-01

    This paper presents an extensive collection of calculated correction factors that account for the combined effects of a wide range of non-ideal conditions often encountered in realistic four-point probe and van der Pauw experiments. In this context, "non-ideal conditions" refer to conditions that deviate from the assumptions on sample and probe characteristics made in the development of these two techniques. We examine the combined effects of contact size and sample thickness on van der Pauw measurements. In the four-point probe configuration, we examine the combined effects of varying the sample's lateral dimensions, probe placement, and sample thickness. We derive an analytical expression to calculate correction factors that account, simultaneously, for finite sample size and asymmetric probe placement in four-point probe experiments. We provide experimental validation of the analytical solution via four-point probe measurements on a thin film rectangular sample with arbitrary probe placement. The finite sample size effect is very significant in four-point probe measurements (especially for a narrow sample) and asymmetric probe placement only worsens such effects. The contribution of conduction in multilayer samples is also studied and found to be substantial; hence, we provide a map of the necessary correction factors. This library of correction factors will enable the design of resistivity measurements with improved accuracy and reproducibility over a wide range of experimental conditions.

  20. The distance between Mars and Venus: measuring global sex differences in personality.

    PubMed

    Del Giudice, Marco; Booth, Tom; Irwing, Paul

    2012-01-01

    Sex differences in personality are believed to be comparatively small. However, research in this area has suffered from significant methodological limitations. We advance a set of guidelines for overcoming those limitations: (a) measure personality with a higher resolution than that afforded by the Big Five; (b) estimate sex differences on latent factors; and (c) assess global sex differences with multivariate effect sizes. We then apply these guidelines to a large, representative adult sample, and obtain what is presently the best estimate of global sex differences in personality. Personality measures were obtained from a large US sample (N = 10,261) with the 16PF Questionnaire. Multigroup latent variable modeling was used to estimate sex differences on individual personality dimensions, which were then aggregated to yield a multivariate effect size (Mahalanobis D). We found a global effect size D = 2.71, corresponding to an overlap of only 10% between the male and female distributions. Even excluding the factor showing the largest univariate ES, the global effect size was D = 1.71 (24% overlap). These are extremely large differences by psychological standards. The idea that there are only minor differences between the personality profiles of males and females should be rejected as based on inadequate methodology.

  1. The Distance Between Mars and Venus: Measuring Global Sex Differences in Personality

    PubMed Central

    Del Giudice, Marco; Booth, Tom; Irwing, Paul

    2012-01-01

    Background Sex differences in personality are believed to be comparatively small. However, research in this area has suffered from significant methodological limitations. We advance a set of guidelines for overcoming those limitations: (a) measure personality with a higher resolution than that afforded by the Big Five; (b) estimate sex differences on latent factors; and (c) assess global sex differences with multivariate effect sizes. We then apply these guidelines to a large, representative adult sample, and obtain what is presently the best estimate of global sex differences in personality. Methodology/Principal Findings Personality measures were obtained from a large US sample (N = 10,261) with the 16PF Questionnaire. Multigroup latent variable modeling was used to estimate sex differences on individual personality dimensions, which were then aggregated to yield a multivariate effect size (Mahalanobis D). We found a global effect size D = 2.71, corresponding to an overlap of only 10% between the male and female distributions. Even excluding the factor showing the largest univariate ES, the global effect size was D = 1.71 (24% overlap). These are extremely large differences by psychological standards. Significance The idea that there are only minor differences between the personality profiles of males and females should be rejected as based on inadequate methodology. PMID:22238596

  2. Macular Ganglion Cell Imaging Study: Covariate Effects on the Spectral Domain Optical Coherence Tomography for Glaucoma Diagnosis

    PubMed Central

    Jeong, Jae Hoon; Choi, Yun Jeong; Park, Ki Ho; Kim, Dong Myung

    2016-01-01

    Purpose To evaluate the effect of multiple covariates on the diagnostic performance of the Cirrus high-definition optical coherence tomography (HD-OCT) for glaucoma detection. Methods A prospective case-control study was performed and included 173 recently diagnosed glaucoma patients and 63 unaffected individuals from the Macular Ganglion Cell Imaging Study. Regression analysis of receiver operating characteristic were conducted to evaluate the influence of age, spherical equivalent, axial length, optic disc size, and visual field index on the macular ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (RNFL) measurements. Results Disease severity, as measured by visual field index, had a significant effect on the diagnostic performance of all Cirrus HD-OCT parameters. Age, axial length and optic disc size were significantly associated with diagnostic accuracy of average peripapillary RNFL thickness, whereas axial length had a significant effect on the diagnostic accuracy of average GCIPL thickness. Conclusions Diagnostic performance of the Cirrus HD-OCT may be more accurate in the advanced stages of glaucoma than at earlier stages. A smaller optic disc size was significantly associated with improved the diagnostic ability of average RNFL thickness measurements; however, GCIPL thickness may be less affected by age and optic disc size. PMID:27490718

  3. The Class Size Debate.

    ERIC Educational Resources Information Center

    Mishel, Lawrence, Ed.; Rothstein, Richard, Ed.

    This collection of papers debates the merits of smaller class sizes and research methods used to evaluate the efficacy of this education reform measure. Four chapters focus on (1) "Understanding the Magnitude and Effect of Class Size on Student Achievement" (Alan B. Krueger), which discusses expenditures per student and economic criterion; (2)…

  4. Network characteristics and patent value—Evidence from the Light-Emitting Diode industry

    PubMed Central

    Huang, Way-Ren; Hsieh, Chia-Jen; Chang, Ke-Chiun; Kiang, Yen-Jo; Yuan, Chien-Chung; Chu, Woei-Chyn

    2017-01-01

    This study proposes a different angle to social network analysis that evaluates patent value and explores its influencing factors using the network centrality and network position. This study utilizes a logistic regression model to explore the relationships in the LED industry between patent value and network centrality as measured from out-degree centrality, in-degree centrality, in-closeness centrality, and network position, which is measured from effect size. The empirical result shows that out-degree centrality and in-degree centrality have significant positive effects on patent value and that effect size has a significant negative effect on patent value. PMID:28817587

  5. Mass Instruction or Higher Learning? The Impact of College Class Size on Student Retention and Graduation

    ERIC Educational Resources Information Center

    Bettinger, Eric P.; Long, Bridget Terry

    2018-01-01

    This paper measures the effects of collegiate class size on college retention and graduation. Class size is a perennial issue in research on primary and secondary schooling. Few researchers have focused on the causal impacts of collegiate class size, however. Whereas college students have greater choice of classes, selection problems and nonrandom…

  6. Accuracy of various impression materials and methods for two implant systems: An effect size study.

    PubMed

    Schmidt, Alexander; Häussling, Teresa; Rehmann, Peter; Schaaf, Heidrun; Wöstmann, Bernd

    2018-04-01

    An accurate impression is required for implant treatment. The aim of this in-vitro study was to determine the effect size of the impression material/method, implant system and implant angulation on impression transfer precision. An upper jaw model with three BEGO and three Straumann implants (angulations 0°, 15°, 20°) in the left and right maxilla was used as a reference model. One polyether (Impregum Penta) and two polyvinyl siloxanes (Flexitime Monophase/Aquasil Ultra Monophase) were examined with two impression techniques (open and closed tray). A total of 60 impressions were made. A coordinate measurement machine was used to measure the target variables for 3D-shift, implant axis inclination and implant axis rotation. All the data were subjected to a four-way ANOVA. The effect size (partial eta-squared [η 2 P ]) was reported. The impression material had a significant influence on the 3D shift and the implant axis inclination deviation (p-values=.000), and both factors had very large effect sizes (3D-shift [η 2 P ]=.599; implant axis inclination [η 2 P ]=.298). Impressions made with polyvinyl siloxane exhibited the highest transfer precision. When the angulation of the implants was larger, more deviations occurred for the implant axis rotational deviation. The implant systems and impression methods showed partially significant variations (p-values=.001-.639) but only very small effect sizes (η 2 P =.001-.031). The impression material had the greatest effect size on accuracy in terms of the 3D shift and the implant axis inclination. For multiunit restorations with disparallel implants, polyvinyl siloxane materials should be considered. In addition, the effect size of a multivariate investigation should be reported. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  7. A meta-analytic review of self-reported, clinician-rated, and performance-based motivation measures in schizophrenia: Are we measuring the same "stuff"?

    PubMed

    Luther, Lauren; Firmin, Ruth L; Lysaker, Paul H; Minor, Kyle S; Salyers, Michelle P

    2018-04-07

    An array of self-reported, clinician-rated, and performance-based measures has been used to assess motivation in schizophrenia; however, the convergent validity evidence for these motivation assessment methods is mixed. The current study is a series of meta-analyses that summarize the relationships between methods of motivation measurement in 45 studies of people with schizophrenia. The overall mean effect size between self-reported and clinician-rated motivation measures (r = 0.27, k = 33) was significant, positive, and approaching medium in magnitude, and the overall effect size between performance-based and clinician-rated motivation measures (r = 0.21, k = 11) was positive, significant, and small in magnitude. The overall mean effect size between self-reported and performance-based motivation measures was negligible and non-significant (r = -0.001, k = 2), but this meta-analysis was underpowered. Findings suggest modest convergent validity between clinician-rated and both self-reported and performance-based motivation measures, but additional work is needed to clarify the convergent validity between self-reported and performance-based measures. Further, there is likely more variability than similarity in the underlying construct that is being assessed across the three methods, particularly between the performance-based and other motivation measurement types. These motivation assessment methods should not be used interchangeably, and measures should be more precisely described as the specific motivational construct or domain they are capturing. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. Measuring an Effect Size from Dichotomized Data: Contrasted Results Whether Using a Correlation or an Odds Ratio

    ERIC Educational Resources Information Center

    Rousson, Valentin

    2014-01-01

    It is well known that dichotomizing continuous data has the effect to decrease statistical power when the goal is to test for a statistical association between two variables. Modern researchers however are focusing not only on statistical significance but also on an estimation of the "effect size" (i.e., the strength of association…

  9. Measuring Response to Intervention: Comparing Three Effect Size Calculation Techniques for Single-Case Design Analysis

    ERIC Educational Resources Information Center

    Ross, Sarah Gwen

    2012-01-01

    Response to intervention (RTI) is increasingly being used in educational settings to make high-stakes, special education decisions. Because of this, the accurate use and analysis of single-case designs to monitor intervention effectiveness has become important to the RTI process. Effect size methods for single-case designs provide a useful way to…

  10. Characterization of magnetic nanoparticle by dynamic light scattering

    PubMed Central

    2013-01-01

    Here we provide a complete review on the use of dynamic light scattering (DLS) to study the size distribution and colloidal stability of magnetic nanoparticles (MNPs). The mathematical analysis involved in obtaining size information from the correlation function and the calculation of Z-average are introduced. Contributions from various variables, such as surface coating, size differences, and concentration of particles, are elaborated within the context of measurement data. Comparison with other sizing techniques, such as transmission electron microscopy and dark-field microscopy, revealed both the advantages and disadvantages of DLS in measuring the size of magnetic nanoparticles. The self-assembly process of MNP with anisotropic structure can also be monitored effectively by DLS. PMID:24011350

  11. Numerical distance effect size is a poor metric of approximate number system acuity.

    PubMed

    Chesney, Dana

    2018-04-12

    Individual differences in the ability to compare and evaluate nonsymbolic numerical magnitudes-approximate number system (ANS) acuity-are emerging as an important predictor in many research areas. Unfortunately, recent empirical studies have called into question whether a historically common ANS-acuity metric-the size of the numerical distance effect (NDE size)-is an effective measure of ANS acuity. NDE size has been shown to frequently yield divergent results from other ANS-acuity metrics. Given these concerns and the measure's past popularity, it behooves us to question whether the use of NDE size as an ANS-acuity metric is theoretically supported. This study seeks to address this gap in the literature by using modeling to test the basic assumption underpinning use of NDE size as an ANS-acuity metric: that larger NDE size indicates poorer ANS acuity. This assumption did not hold up under test. Results demonstrate that the theoretically ideal relationship between NDE size and ANS acuity is not linear, but rather resembles an inverted J-shaped distribution, with the inflection points varying based on precise NDE task methodology. Thus, depending on specific methodology and the distribution of ANS acuity in the tested population, positive, negative, or null correlations between NDE size and ANS acuity could be predicted. Moreover, peak NDE sizes would be found for near-average ANS acuities on common NDE tasks. This indicates that NDE size has limited and inconsistent utility as an ANS-acuity metric. Past results should be interpreted on a case-by-case basis, considering both specifics of the NDE task and expected ANS acuity of the sampled population.

  12. Measurements of Regolith Simulant Thermal Conductivity Under Asteroid and Mars Surface Conditions

    NASA Astrophysics Data System (ADS)

    Ryan, A. J.; Christensen, P. R.

    2017-12-01

    Laboratory measurements have been necessary to interpret thermal data of planetary surfaces for decades. We present a novel radiometric laboratory method to determine temperature-dependent thermal conductivity of complex regolith simulants under rough to high vacuum and across a wide range of temperatures. This method relies on radiometric temperature measurements instead of contact measurements, eliminating the need to disturb the sample with thermal probes. We intend to determine the conductivity of grains that are up to 2 cm in diameter and to parameterize the effects of angularity, sorting, layering, composition, and eventually cementation. We present the experimental data and model results for a suite of samples that were selected to isolate and address regolith physical parameters that affect bulk conductivity. Spherical glass beads of various sizes were used to measure the effect of size frequency distribution. Spherical beads of polypropylene and well-rounded quartz sand have respectively lower and higher solid phase thermal conductivities than the glass beads and thus provide the opportunity to test the sensitivity of bulk conductivity to differences in solid phase conductivity. Gas pressure in our asteroid experimental chambers is held at 10^-6 torr, which is sufficient to negate gas thermal conduction in even our coarsest of samples. On Mars, the atmospheric pressure is such that the mean free path of the gas molecules is comparable to the pore size for many regolith particulates. Thus, subtle variations in pore size and/or atmospheric pressure can produce large changes in bulk regolith conductivity. For each sample measured in our martian environmental chamber, we repeat thermal measurement runs at multiple pressures to observe this behavior. Finally, we present conductivity measurements of angular basaltic simulant that is physically analogous to sand and gravel that may be present on Bennu. This simulant was used for OSIRIS-REx TAGSAM Sample Return Arm engineering tests. We measure the original size frequency distribution as well as several sorted size fractions. These results will support the efforts of the OSIRIS-REx team in selecting a site on asteroid Bennu that is safe for the spacecraft and meets grain size requirements for sampling.

  13. Small and inconsistent effects of whole body vibration on athletic performance: a systematic review and meta-analysis.

    PubMed

    Hortobágyi, Tibor; Lesinski, Melanie; Fernandez-Del-Olmo, Miguel; Granacher, Urs

    2015-08-01

    We quantified the acute and chronic effects of whole body vibration on athletic performance or its proxy measures in competitive and/or elite athletes. Systematic literature review and meta-analysis. Whole body vibration combined with exercise had an overall 0.3 % acute effect on maximal voluntary leg force (-6.4 %, effect size = -0.43, 1 study), leg power (4.7 %, weighted mean effect size = 0.30, 6 studies), flexibility (4.6 %, effect size = -0.12 to 0.22, 2 studies), and athletic performance (-1.9 %, weighted mean effect size = 0.26, 6 studies) in 191 (103 male, 88 female) athletes representing eight sports (overall effect size = 0.28). Whole body vibration combined with exercise had an overall 10.2 % chronic effect on maximal voluntary leg force (14.6 %, weighted mean effect size = 0.44, 5 studies), leg power (10.7 %, weighted mean effect size = 0.42, 9 studies), flexibility (16.5 %, effect size = 0.57 to 0.61, 2 studies), and athletic performance (-1.2 %, weighted mean effect size = 0.45, 5 studies) in 437 (169 male, 268 female) athletes (overall effect size = 0.44). Whole body vibration has small and inconsistent acute and chronic effects on athletic performance in competitive and/or elite athletes. These findings lead to the hypothesis that neuromuscular adaptive processes following whole body vibration are not specific enough to enhance athletic performance. Thus, other types of exercise programs (e.g., resistance training) are recommended if the goal is to improve athletic performance.

  14. Effects of Sample Preparation on the Infrared Reflectance Spectra of Powders

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brauer, Carolyn S.; Johnson, Timothy J.; Myers, Tanya L.

    2015-05-22

    While reflectance spectroscopy is a useful tool in identifying molecular compounds, laboratory measurement of solid (particularly powder) samples often is confounded by sample preparation methods. For example, both the packing density and surface roughness can have an effect on the quantitative reflectance spectra of powdered samples. Recent efforts in our group have focused on developing standard methods for measuring reflectance spectra that accounts for sample preparation, as well as other factors such as particle size and provenance. In this work, the effect of preparation method on sample reflectivity was investigated by measuring the directional-hemispherical spectra of samples that were hand-packedmore » as well as pressed into pellets using an integrating sphere attached to a Fourier transform infrared spectrometer. The results show that the methods used to prepare the sample have a substantial effect on the measured reflectance spectra, as do other factors such as particle size.« less

  15. Effects of sample preparation on the infrared reflectance spectra of powders

    NASA Astrophysics Data System (ADS)

    Brauer, Carolyn S.; Johnson, Timothy J.; Myers, Tanya L.; Su, Yin-Fong; Blake, Thomas A.; Forland, Brenda M.

    2015-05-01

    While reflectance spectroscopy is a useful tool for identifying molecular compounds, laboratory measurement of solid (particularly powder) samples often is confounded by sample preparation methods. For example, both the packing density and surface roughness can have an effect on the quantitative reflectance spectra of powdered samples. Recent efforts in our group have focused on developing standard methods for measuring reflectance spectra that accounts for sample preparation, as well as other factors such as particle size and provenance. In this work, the effect of preparation method on sample reflectivity was investigated by measuring the directional-hemispherical spectra of samples that were hand-loaded as well as pressed into pellets using an integrating sphere attached to a Fourier transform infrared spectrometer. The results show that the methods used to prepare the sample can have a substantial effect on the measured reflectance spectra, as do other factors such as particle size.

  16. Friction between footwear and floor covered with solid particles under dry and wet conditions.

    PubMed

    Li, Kai Way; Meng, Fanxing; Zhang, Wei

    2014-01-01

    Solid particles on the floor, both dry and wet, are common but their effects on the friction on the floor were seldom discussed in the literature. In this study, friction measurements were conducted to test the effects of particle size of solid contaminants on the friction coefficient on the floor under footwear, floor, and surface conditions. The results supported the hypothesis that particle size of solids affected the friction coefficient and the effects depended on footwear, floor, and surface conditions. On dry surfaces, solid particles resulted in friction loss when the Neolite footwear pad was used. On the other hand, solid particles provided additional friction when measured with the ethylene vinyl acetate (EVA) footwear pad. On wet surfaces, introducing solid particles made the floors more slip-resistant and such effects depended on particle size. This study provides information for better understanding of the mechanism of slipping when solid contaminants are present.

  17. Opposing brain differences in 16p11.2 deletion and duplication carriers.

    PubMed

    Qureshi, Abid Y; Mueller, Sophia; Snyder, Abraham Z; Mukherjee, Pratik; Berman, Jeffrey I; Roberts, Timothy P L; Nagarajan, Srikantan S; Spiro, John E; Chung, Wendy K; Sherr, Elliott H; Buckner, Randy L

    2014-08-20

    Deletions and duplications of the recurrent ~600 kb chromosomal BP4-BP5 region of 16p11.2 are associated with a broad variety of neurodevelopmental outcomes including autism spectrum disorder. A clue to the pathogenesis of the copy number variant (CNV)'s effect on the brain is that the deletion is associated with a head size increase, whereas the duplication is associated with a decrease. Here we analyzed brain structure in a clinically ascertained group of human deletion (N = 25) and duplication (N = 17) carriers from the Simons Variation in Individuals Project compared with age-matched controls (N = 29 and 33, respectively). Multiple brain measures showed increased size in deletion carriers and reduced size in duplication carriers. The effects spanned global measures of intracranial volume, brain size, compartmental measures of gray matter and white matter, subcortical structures, and the cerebellum. Quantitatively, the largest effect was on the thalamus, but the collective results suggest a pervasive rather than a selective effect on the brain. Detailed analysis of cortical gray matter revealed that cortical surface area displays a strong dose-dependent effect of CNV (deletion > control > duplication), whereas average cortical thickness is less affected. These results suggest that the CNV may exert its opposing influences through mechanisms that influence early stages of embryonic brain development. Copyright © 2014 the authors 0270-6474/14/3411199-13$15.00/0.

  18. Eliciting mixed emotions: a meta-analysis comparing models, types, and measures.

    PubMed

    Berrios, Raul; Totterdell, Peter; Kellett, Stephen

    2015-01-01

    The idea that people can experience two oppositely valenced emotions has been controversial ever since early attempts to investigate the construct of mixed emotions. This meta-analysis examined the robustness with which mixed emotions have been elicited experimentally. A systematic literature search identified 63 experimental studies that instigated the experience of mixed emotions. Studies were distinguished according to the structure of the underlying affect model-dimensional or discrete-as well as according to the type of mixed emotions studied (e.g., happy-sad, fearful-happy, positive-negative). The meta-analysis using a random-effects model revealed a moderate to high effect size for the elicitation of mixed emotions (d IG+ = 0.77), which remained consistent regardless of the structure of the affect model, and across different types of mixed emotions. Several methodological and design moderators were tested. Studies using the minimum index (i.e., the minimum value between a pair of opposite valenced affects) resulted in smaller effect sizes, whereas subjective measures of mixed emotions increased the effect sizes. The presence of more women in the samples was also associated with larger effect sizes. The current study indicates that mixed emotions are a robust, measurable and non-artifactual experience. The results are discussed in terms of the implications for an affect system that has greater versatility and flexibility than previously thought.

  19. Eliciting mixed emotions: a meta-analysis comparing models, types, and measures

    PubMed Central

    Berrios, Raul; Totterdell, Peter; Kellett, Stephen

    2015-01-01

    The idea that people can experience two oppositely valenced emotions has been controversial ever since early attempts to investigate the construct of mixed emotions. This meta-analysis examined the robustness with which mixed emotions have been elicited experimentally. A systematic literature search identified 63 experimental studies that instigated the experience of mixed emotions. Studies were distinguished according to the structure of the underlying affect model—dimensional or discrete—as well as according to the type of mixed emotions studied (e.g., happy-sad, fearful-happy, positive-negative). The meta-analysis using a random-effects model revealed a moderate to high effect size for the elicitation of mixed emotions (dIG+ = 0.77), which remained consistent regardless of the structure of the affect model, and across different types of mixed emotions. Several methodological and design moderators were tested. Studies using the minimum index (i.e., the minimum value between a pair of opposite valenced affects) resulted in smaller effect sizes, whereas subjective measures of mixed emotions increased the effect sizes. The presence of more women in the samples was also associated with larger effect sizes. The current study indicates that mixed emotions are a robust, measurable and non-artifactual experience. The results are discussed in terms of the implications for an affect system that has greater versatility and flexibility than previously thought. PMID:25926805

  20. Reading at a distance: implications for the design of text in children's big books.

    PubMed

    Hughes, Laura E; Wilkins, Arnold J

    2002-06-01

    Visual acuity, typically measured by the ability to name letters at a distance, is poorer when letters are small and closely spaced. It has been suggested that reading can be affected by letter size and spacing. To determine the effect of text size and spacing on the ability to read at a distance, with a view to helping with the design of text in children's 'Big Books'. The visual acuity of 200 children aged between 6 and 12 was measured. A subset of 66 children was given further reading tests. From a viewing distance of 3m children were required (1) to identify words and (2) to read passages of text rapidly. A repeated measures design was used to compare the effects of different size and spacing of text on performance of the two tasks. Performance improved when the spacing of words and size of letters was greater than is typical in 'Big Books'. For a given letter density, increasing the spacing improved performance more than increasing the letter size. The text in children's books could be made easier to read by expanding the spacing between words and also by increasing the size of the print. The maximum viewing distance should be reduced from 15ft (4.6m) to 10ft (3.0m).

  1. Revealing life-history traits by contrasting genetic estimations with predictions of effective population size.

    PubMed

    Greenbaum, Gili; Renan, Sharon; Templeton, Alan R; Bouskila, Amos; Saltz, David; Rubenstein, Daniel I; Bar-David, Shirli

    2017-12-22

    Effective population size, a central concept in conservation biology, is now routinely estimated from genetic surveys and can also be theoretically predicted from demographic, life-history, and mating-system data. By evaluating the consistency of theoretical predictions with empirically estimated effective size, insights can be gained regarding life-history characteristics and the relative impact of different life-history traits on genetic drift. These insights can be used to design and inform management strategies aimed at increasing effective population size. We demonstrated this approach by addressing the conservation of a reintroduced population of Asiatic wild ass (Equus hemionus). We estimated the variance effective size (N ev ) from genetic data (N ev =24.3) and formulated predictions for the impacts on N ev of demography, polygyny, female variance in lifetime reproductive success (RS), and heritability of female RS. By contrasting the genetic estimation with theoretical predictions, we found that polygyny was the strongest factor affecting genetic drift because only when accounting for polygyny were predictions consistent with the genetically measured N ev . The comparison of effective-size estimation and predictions indicated that 10.6% of the males mated per generation when heritability of female RS was unaccounted for (polygyny responsible for 81% decrease in N ev ) and 19.5% mated when female RS was accounted for (polygyny responsible for 67% decrease in N ev ). Heritability of female RS also affected N ev ; hf2=0.91 (heritability responsible for 41% decrease in N ev ). The low effective size is of concern, and we suggest that management actions focus on factors identified as strongly affecting Nev, namely, increasing the availability of artificial water sources to increase number of dominant males contributing to the gene pool. This approach, evaluating life-history hypotheses in light of their impact on effective population size, and contrasting predictions with genetic measurements, is a general, applicable strategy that can be used to inform conservation practice. © 2017 Society for Conservation Biology.

  2. The Relative Impacts of Disease on Health Status and Capability Wellbeing: A Multi-Country Study

    PubMed Central

    Mitchell, Paul Mark; Al-Janabi, Hareth; Richardson, Jeff; Iezzi, Angelo; Coast, Joanna

    2015-01-01

    Background Evaluations of the impact of interventions for resource allocation purposes commonly focus on health status. There is, however, also concern about broader impacts on wellbeing and, increasingly, on a person's capability. This study aims to compare the impact on health status and capability of seven major health conditions, and highlight differences in treatment priorities when outcomes are measured by capability as opposed to health status. Methods The study was a cross-sectional four country survey (n = 6650) of eight population groups: seven disease groups with: arthritis, asthma, cancer, depression, diabetes, hearing loss, and heart disease and one health population ‘comparator’ group. Two simple self-complete questionnaires were used to measure health status (EQ-5D-5L) and capability (ICECAP-A). Individuals were classified by illness severity using condition-specific questionnaires. Effect sizes were used to estimate: (i) the difference in health status and capability for those with conditions, relative to a healthy population; and (ii) the impact of the severity of the condition on health status and capability within each disease group. Findings 5248 individuals were included in the analysis. Individuals with depression have the greatest mean reduction in both health (effect size, 1.26) and capability (1.22) compared to the healthy population. The effect sizes for capability for depression are much greater than for all other conditions, which is not the case for health. For example, the arthritis group effect size for health (1.24) is also high and similar to that of depression, whereas for the same arthritis group, the effect size for capability is much lower than that for depression (0.55). In terms of severity within disease groups, individuals categorised as 'mild' have similar capability levels to the healthy population (effect sizes <0.2, excluding depression) but lower health status than the healthy population (≥0.4). Conclusion Significant differences exist in the relative effect sizes across diseases when measured by health status and capability. In terms of treating morbidity, a shift in focus from health gain to capability gain would increase funding priorities for patients with depression specifically and severe illnesses more generally. PMID:26630131

  3. Impact of particle concentration and out-of-range sizes on the measurements of the LISST

    NASA Astrophysics Data System (ADS)

    Zhao, Lin; Boufadel, Michel C.; King, Thomas; Robinson, Brian; Conmy, Robyn; Lee, Kenneth

    2018-05-01

    The instrument LISST (laser in situ scattering and transmissiometry) has been widely used for measuring the size of oil droplets in relation to oil spills and sediment particles. Major concerns associated with using the instrument include the impact of high concentrations and/or out-of-range particle (droplet) sizes on the LISST reading. These were evaluated experimentally in this study using monosized microsphere particles. The key findings include: (1) When high particle concentration reduced the optical transmission (OT) to below 30%, the measured peak value tended to underestimate the true peak value, and the accuracy of the LISST decreased by ~8% to ~28%. The maximum concentration to reach the 30% OT was about 50% of the theoretical values, suggesting a lower concentration level should be considered during the instrument deployment. (2) The out-of-range sizes of particles affected the LISST measurements when the sizes were close to the LISST measurement range. Fine below-range sizes primarily affected the data in the lowest two bins of the LISST with  >75% of the volume at the smallest bin. Large out-of-range particles affected the sizes of the largest 8–10 bins only when very high concentration was present. The out-of-range particles slightly changed the size distribution of the in-range particles, but their concentration was conserved. An approach to interpret and quantify the effects of the out-of-range particles on the LISST measurement was proposed.

  4. Indentation size effects in single crystal copper as revealed by synchrotron x-ray microdiffraction

    NASA Astrophysics Data System (ADS)

    Feng, G.; Budiman, A. S.; Nix, W. D.; Tamura, N.; Patel, J. R.

    2008-08-01

    For a Cu single crystal, we find that indentation hardness increases with decreasing indentation depth, a phenomenon widely observed before and called the indentation size effect (ISE). To understand the underlying mechanism, we measure the lattice rotations in indentations of different sizes using white beam x-ray microdiffraction (μXRD); the indentation-induced lattice rotations are directly measured by the streaking of x-ray Laue spots associated with the indentations. The magnitude of the lattice rotations is found to be independent of indentation size, which is consistent with the basic tenets of the ISE model. Using the μXRD data together with an ISE model, we can estimate the effective radius of the indentation plastic zone, and the estimate is consistent with the value predicted by a finite element analysis. Using these results, an estimate of the average dislocation densities within the plastic zones has been made; the findings are consistent with the ISE arising from a dependence of the dislocation density on the depth of indentation.

  5. Robust organelle size extractions from elastic scattering measurements of single cells (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Cannaday, Ashley E.; Draham, Robert; Berger, Andrew J.

    2016-04-01

    The goal of this project is to estimate non-nuclear organelle size distributions in single cells by measuring angular scattering patterns and fitting them with Mie theory. Simulations have indicated that the large relative size distribution of organelles (mean:width≈2) leads to unstable Mie fits unless scattering is collected at polar angles less than 20 degrees. Our optical system has therefore been modified to collect angles down to 10 degrees. Initial validations will be performed on polystyrene bead populations whose size distributions resemble those of cell organelles. Unlike with the narrow bead distributions that are often used for calibration, we expect to see an order-of-magnitude improvement in the stability of the size estimates as the minimum angle decreases from 20 to 10 degrees. Scattering patterns will then be acquired and analyzed from single cells (EMT6 mouse cancer cells), both fixed and live, at multiple time points. Fixed cells, with no changes in organelle sizes over time, will be measured to determine the fluctuation level in estimated size distribution due to measurement imperfections alone. Subsequent measurements on live cells will determine whether there is a higher level of fluctuation that could be attributed to dynamic changes in organelle size. Studies on unperturbed cells are precursors to ones in which the effects of exogenous agents are monitored over time.

  6. Relative importance of expertise, lifting height and weight lifted on posture and lumbar external loading during a transfer task in manual material handling.

    PubMed

    Plamondon, André; Larivière, Christian; Delisle, Alain; Denis, Denys; Gagnon, Denis

    2012-01-01

    The objective of this study was to measure the effect size of three important factors in manual material handling, namely expertise, lifting height and weight lifted. The effect of expertise was evaluated by contrasting 15 expert and 15 novice handlers, the effect of the weight lifted with a 15-kg box and a 23-kg box and the effect of lifting height with two different box heights: ground level and a 32 cm height. The task consisted of transferring a series of boxes from a conveyor to a hand trolley. Lifting height and weight lifted had more effect size than expertise on external back loading variables (moments) while expertise had low impact. On the other hand, expertise showed a significant effect of posture variables on the lumbar spine and knees. All three factors are important, but for a reduction of external back loading, the focus should be on the lifting height and weight lifted. The objective was to measure the effect size of three important factors in a transfer of boxes from a conveyor to a hand trolley. Lifting height and weight lifted had more effect size than expertise on external back loading variables but expertise was a major determinant in back posture.

  7. The Impact of Multiple Endpoint Dependency on "Q" and "I"[superscript 2] in Meta-Analysis

    ERIC Educational Resources Information Center

    Thompson, Christopher Glen; Becker, Betsy Jane

    2014-01-01

    A common assumption in meta-analysis is that effect sizes are independent. When correlated effect sizes are analyzed using traditional univariate techniques, this assumption is violated. This research assesses the impact of dependence arising from treatment-control studies with multiple endpoints on homogeneity measures "Q" and…

  8. Estimating an Effect Size in One-Way Multivariate Analysis of Variance (MANOVA)

    ERIC Educational Resources Information Center

    Steyn, H. S., Jr.; Ellis, S. M.

    2009-01-01

    When two or more univariate population means are compared, the proportion of variation in the dependent variable accounted for by population group membership is eta-squared. This effect size can be generalized by using multivariate measures of association, based on the multivariate analysis of variance (MANOVA) statistics, to establish whether…

  9. Introducing the Mean Absolute Deviation "Effect" Size

    ERIC Educational Resources Information Center

    Gorard, Stephen

    2015-01-01

    This paper revisits the use of effect sizes in the analysis of experimental and similar results, and reminds readers of the relative advantages of the mean absolute deviation as a measure of variation, as opposed to the more complex standard deviation. The mean absolute deviation is easier to use and understand, and more tolerant of extreme…

  10. An Analytic Comparison of Effect Sizes for Differential Item Functioning

    ERIC Educational Resources Information Center

    Demars, Christine E.

    2011-01-01

    Three types of effects sizes for DIF are described in this exposition: log of the odds-ratio (differences in log-odds), differences in probability-correct, and proportion of variance accounted for. Using these indices involves conceptualizing the degree of DIF in different ways. This integrative review discusses how these measures are impacted in…

  11. Sample Size Estimation for Alzheimer's Disease Trials from Japanese ADNI Serial Magnetic Resonance Imaging.

    PubMed

    Fujishima, Motonobu; Kawaguchi, Atsushi; Maikusa, Norihide; Kuwano, Ryozo; Iwatsubo, Takeshi; Matsuda, Hiroshi

    2017-01-01

    Little is known about the sample sizes required for clinical trials of Alzheimer's disease (AD)-modifying treatments using atrophy measures from serial brain magnetic resonance imaging (MRI) in the Japanese population. The primary objective of the present study was to estimate how large a sample size would be needed for future clinical trials for AD-modifying treatments in Japan using atrophy measures of the brain as a surrogate biomarker. Sample sizes were estimated from the rates of change of the whole brain and hippocampus by the k-means normalized boundary shift integral (KN-BSI) and cognitive measures using the data of 537 Japanese Alzheimer's Neuroimaging Initiative (J-ADNI) participants with a linear mixed-effects model. We also examined the potential use of ApoE status as a trial enrichment strategy. The hippocampal atrophy rate required smaller sample sizes than cognitive measures of AD and mild cognitive impairment (MCI). Inclusion of ApoE status reduced sample sizes for AD and MCI patients in the atrophy measures. These results show the potential use of longitudinal hippocampal atrophy measurement using automated image analysis as a progression biomarker and ApoE status as a trial enrichment strategy in a clinical trial of AD-modifying treatment in Japanese people.

  12. A Miniature Aerosol Sensor for Detecting Polydisperse Airborne Ultrafine Particles.

    PubMed

    Zhang, Chao; Wang, Dingqu; Zhu, Rong; Yang, Wenming; Jiang, Peng

    2017-04-22

    Counting and sizing of polydisperse airborne nanoparticles have attracted most attentions owing to increasing widespread presence of airborne engineered nanoparticles or ultrafine particles. Here we report a miniature aerosol sensor to detect particle size distribution of polydisperse ultrafine particles based on ion diffusion charging and electrical detection. The aerosol sensor comprises a couple of planar electrodes printed on two circuit boards assembled in parallel, where charging, precipitation and measurement sections are integrated into one chip, which can detect aerosol particle size in of 30-500 nm, number concentration in range of 5 × 10²-10⁷ /cm³. The average relative errors of the measured aerosol number concentration and the particle size are estimated to be 12.2% and 13.5% respectively. A novel measurement scheme is proposed to actualize a real-time detection of polydisperse particles by successively modulating the measurement voltage and deducing the particle size distribution through a smart data fusion algorithm. The effectiveness of the aerosol sensor is experimentally demonstrated via measurements of polystyrene latex (PSL) aerosol and nucleic acid aerosol, as well as sodium chloride aerosol particles.

  13. Determination of a temperature sensor location for monitoring weld pool size in GMAW

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Boo, K.S.; Cho, H.S.

    1994-11-01

    This paper describes a method of determining the optimal sensor location to measure weldment surface temperature, which has a close correlation with weld pool size in the gas metal arc (GMA) welding process. Due to the inherent complexity and nonlinearity in the GMA welding process, the relationship between the weldment surface temperature and the weld pool size varies with the point of measurement. This necessitates an optimal selection of the measurement point to minimize the process nonlinearity effect in estimating the weld pool size from the measured temperature. To determine the optimal sensor location on the top surface of themore » weldment, the correlation between the measured temperature and the weld pool size is analyzed. The analysis is done by calculating the correlation function, which is based upon an analytical temperature distribution model. To validate the optimal sensor location, a series of GMA bead-on-plate welds are performed on a medium-carbon steel under various welding conditions. A comparison study is given in detail based upon the simulation and experimental results.« less

  14. A Miniature Aerosol Sensor for Detecting Polydisperse Airborne Ultrafine Particles

    PubMed Central

    Zhang, Chao; Wang, Dingqu; Zhu, Rong; Yang, Wenming; Jiang, Peng

    2017-01-01

    Counting and sizing of polydisperse airborne nanoparticles have attracted most attentions owing to increasing widespread presence of airborne engineered nanoparticles or ultrafine particles. Here we report a miniature aerosol sensor to detect particle size distribution of polydisperse ultrafine particles based on ion diffusion charging and electrical detection. The aerosol sensor comprises a couple of planar electrodes printed on two circuit boards assembled in parallel, where charging, precipitation and measurement sections are integrated into one chip, which can detect aerosol particle size in of 30–500 nm, number concentration in range of 5 × 102–5 × 107 /cm3. The average relative errors of the measured aerosol number concentration and the particle size are estimated to be 12.2% and 13.5% respectively. A novel measurement scheme is proposed to actualize a real-time detection of polydisperse particles by successively modulating the measurement voltage and deducing the particle size distribution through a smart data fusion algorithm. The effectiveness of the aerosol sensor is experimentally demonstrated via measurements of polystyrene latex (PSL) aerosol and nucleic acid aerosol, as well as sodium chloride aerosol particles. PMID:28441740

  15. Open-Label Milnacipran for Patients With Persistent Knee Pain 1 Year or Longer After Total Knee Arthroplasty: A Pilot Study

    PubMed Central

    Bolognesi, Michael P.

    2013-01-01

    Objective: The current study investigates whether milnacipran is effective in reducing pain and improving function in patients with persistent pain ≥ 1 year after total knee arthroplasty. Method: This was a 12-week open-label study of flexibly dosed milnacipran in patients (N = 5) experiencing chronic persistent knee pain ≥ 1 year following total knee arthroplasty in the absence of new injury, infection, or implant failure. Subjects were identified from October 2010 to August 2011 through the Duke University Medical Center orthopedic clinic (Durham, North Carolina), typically during 1-year postoperative follow-up visits, and were referred by their orthopedic surgeon. Results: Milnacipran treatment was associated with reduction in pain according to the primary outcome measure of the visual analog scale (VAS) score for pain (effect size of 1.15) and secondary outcome measures of Knee Society Score (KSS) evaluation subscale score (effect size of 1.37) and Medical Outcomes Study 36-item Short-Form Health Survey (SF-36) bodily pain subscale (effect size of 1.16) at week 12. Secondary outcome measures of functional change were mixed in such that, at week 12, the SF-36 physical functioning subscale showed improvement (effect size of 1.16), but the KSS function subscale score was just below the threshold for meaningful effect size (0.98). Conclusions: Open-label milnacipran demonstrated reduced pain and some evidence of functional improvement in this small sample of patients with chronic persistent pain 1 year or more after total knee arthroplasty such that well-powered studies are warranted. Trial Registration: ClinicalTrials.gov identifier: NCT01780389 PMID:24392250

  16. Specific heat capacity of molten salt-based alumina nanofluid.

    PubMed

    Lu, Ming-Chang; Huang, Chien-Hsun

    2013-06-21

    There is no consensus on the effect of nanoparticle (NP) addition on the specific heat capacity (SHC) of fluids. In addition, the predictions from the existing model have a large discrepancy from the measured SHCs in nanofluids. We show that the SHC of the molten salt-based alumina nanofluid decreases with reducing particle size and increasing particle concentration. The NP size-dependent SHC is resulted from an augmentation of the nanolayer effect as particle size reduces. A model considering the nanolayer effect which supports the experimental results was proposed.

  17. Specific heat capacity of molten salt-based alumina nanofluid

    PubMed Central

    2013-01-01

    There is no consensus on the effect of nanoparticle (NP) addition on the specific heat capacity (SHC) of fluids. In addition, the predictions from the existing model have a large discrepancy from the measured SHCs in nanofluids. We show that the SHC of the molten salt-based alumina nanofluid decreases with reducing particle size and increasing particle concentration. The NP size-dependent SHC is resulted from an augmentation of the nanolayer effect as particle size reduces. A model considering the nanolayer effect which supports the experimental results was proposed. PMID:23800321

  18. Empathy in boys with gender identity disorder: a comparison to externalizing clinical control boys and community control boys and girls.

    PubMed

    Owen-Anderson, Allison F H; Jenkins, Jennifer M; Bradley, Susan J; Zucker, Kenneth J

    2008-03-01

    The construct of empathy was examined in 20 boys with gender identity disorder (GID), 20 clinical control boys with externalizing disorders (ECC), 20 community control boys (NCB), and 20 community control girls (NCG). The mean age of the children was 6.86 years (range = 4-8 years). It was hypothesized that boys with GID would show similar levels of empathy to those shown by NC girls and higher levels of empathy than the NC and ECC boys. Three measures of empathy were administered: a maternal-report questionnaire, a self-report questionnaire, and an in vivo evaluation in which children's reactions to pain simulations to two adult actors (mother, experimenter) were coded for empathy levels. On the maternal report and in-vivo measures, the NC girls had significantly higher empathy levels than the NC boys, but not on the self-report measure. By maternal report, the NC girls were rated as significantly more empathic than were the GID boys, with a "large" effect size. There were no significant differences between the GID boys and the NC girls on the self-report and in-vivo measures and the effect size differences were "small." No significant differences were observed between the GID and NC boys; however, there were "medium" and "small" effect size differences with boys with GID showing more empathy on the in-vivo and self-report measures, respectively. On the maternal-report measure, the GID boys were rated as significantly more empathic than the ECC boys and there was a trend for the GID boys to show greater levels of empathy than the ECC boys on both the self-report and in-vivo measures. The effect size differences on all three empathy measures were "medium" to "large," with GID boys showing more empathy than ECC boys. Empathy as a dispositional characteristic in the genesis and perpetuation of GID in boys is discussed.

  19. Eta Squared and Partial Eta Squared as Measures of Effect Size in Educational Research

    ERIC Educational Resources Information Center

    Richardson, John T. E.

    2011-01-01

    Eta squared measures the proportion of the total variance in a dependent variable that is associated with the membership of different groups defined by an independent variable. Partial eta squared is a similar measure in which the effects of other independent variables and interactions are partialled out. The development of these measures is…

  20. The effect of shredding and test apparatus size on compressibility and strength parameters of degraded municipal solid waste.

    PubMed

    Hossain, M S; Gabr, M A; Asce, F

    2009-09-01

    In many situations, MSW components are processed and shredded before use in laboratory experiments using conventional soil testing apparatus. However, shredding MSW material may affect the target property to be measured. The objective of this study is to contribute to the understanding of the effect of shredding of MSW on the measured compressibility and strength properties. It is hypothesized that measured properties can be correlated to an R-value, the ratio of waste particle size to apparatus size. Results from oedometer tests, conducted on 63.5 mm, 100 mm, 200 mm diameter apparatus, indicated the dependency of the compressibility parameters on R-value. The compressibility parameters are similar for the same R-value even though the apparatus size varies. The results using same apparatus size with variable R-values indicated that shredding of MSW mainly affects initial compression. Creep and biological strain rate of the tested MSW are not significantly affected by R-value. The shear strength is affected by shredding as the light-weight reinforcing materials are shredded into smaller pieces during specimen preparation. For example, the measured friction angles are 32 degrees and 27 degrees for maximum particle sizes of 50 mm and 25 mm, respectively. The larger MSW components in the specimen provide better reinforcing contribution. This conclusion is however dependent on comparing specimen at the same level of degradation since shear strength is also a function of extent of degradation.

  1. Effective Ice Particle Densities for Cold Anvil Cirrus

    NASA Technical Reports Server (NTRS)

    Heymsfield, Andrew J.; Schmitt, Carl G.; Bansemer, Aaron; Baumgardner, Darrel; Weinstock, Elliot M.; Smith, Jessica

    2002-01-01

    This study derives effective ice particle densities from data collected from the NASA WB-57F aircraft near the tops of anvils during the Cirrus Regional Study of Tropical Anvils and Cirrus Layers (CRYSTAL) Florida Area Cirrus Experiment (FACE) in southern Florida in July 2002. The effective density, defined as the ice particle mass divided by the volume of an equivalent diameter liquid sphere, is obtained for particle populations and single sizes containing mixed particle habits using measurements of condensed water content and particle size distributions. The mean effective densities for populations decrease with increasing slopes of the gamma size distributions fitted to the size distributions. The population-mean densities range from near 0.91 g/cu m to 0.15 g/cu m. Effective densities for single sizes obey a power-law with an exponent of about -0.55, somewhat less steep than found from earlier studies. Our interpretations apply to samples where particle sizes are generally below 200-300 microns in maximum dimension because of probe limitations.

  2. Understanding the Role of P Values and Hypothesis Tests in Clinical Research.

    PubMed

    Mark, Daniel B; Lee, Kerry L; Harrell, Frank E

    2016-12-01

    P values and hypothesis testing methods are frequently misused in clinical research. Much of this misuse appears to be owing to the widespread, mistaken belief that they provide simple, reliable, and objective triage tools for separating the true and important from the untrue or unimportant. The primary focus in interpreting therapeutic clinical research data should be on the treatment ("oomph") effect, a metaphorical force that moves patients given an effective treatment to a different clinical state relative to their control counterparts. This effect is assessed using 2 complementary types of statistical measures calculated from the data, namely, effect magnitude or size and precision of the effect size. In a randomized trial, effect size is often summarized using constructs, such as odds ratios, hazard ratios, relative risks, or adverse event rate differences. How large a treatment effect has to be to be consequential is a matter for clinical judgment. The precision of the effect size (conceptually related to the amount of spread in the data) is usually addressed with confidence intervals. P values (significance tests) were first proposed as an informal heuristic to help assess how "unexpected" the observed effect size was if the true state of nature was no effect or no difference. Hypothesis testing was a modification of the significance test approach that envisioned controlling the false-positive rate of study results over many (hypothetical) repetitions of the experiment of interest. Both can be helpful but, by themselves, provide only a tunnel vision perspective on study results that ignores the clinical effects the study was conducted to measure.

  3. Measurement of variation in soil solute tracer concentration across a range of effective pore sizes

    USGS Publications Warehouse

    Harvey, Judson W.

    1993-01-01

    Solute transport concepts in soil are based on speculation that solutes are distributed nonuniformly within large and small pores. Solute concentrations have not previously been measured across a range of pore sizes and examined in relation to soil hydrological properties. For this study, modified pressure cells were used to measure variation in concentration of a solute tracer across a range of pore sizes. Intact cores were removed from the site of a field tracer experiment, and soil water was eluted from 10 or more discrete classes of pore size. Simultaneous changes in water content and unsaturated hydraulic conductivity were determined on cores using standard pressure cell techniques. Bromide tracer concentration varied by as much as 100% across the range of pore sizes sampled. Immediately following application of the bromide tracer on field plots, bromide was most concentrated in the largest pores; concentrations were lower in pores of progressively smaller sizes. After 27 days, bromide was most dilute in the largest pores and concentrations were higher in the smaller pores. A sharp, threefold decrease in specific water capacity during elution indicated separation of two major pore size classes at a pressure of 47 cm H2O and a corresponding effective pore diameter of 70 μm. Variation in tracer concentration, on the other hand, was spread across the entire range of pore sizes investigated in this study. A two-porosity characterization of the transport domain, based on water retention criteria, only broadly characterized the pattern of variation in tracer concentration across pore size classes during transport through a macroporous soil.

  4. Comparison of drop size and velocity measurements by a laser precipitation meter and low-speed photography for an agriculture sprinkler

    USDA-ARS?s Scientific Manuscript database

    Kinetic energy of water droplets has a substantial effect on development of a soil surface seal and infiltration rate of bare soil. Methods for measuring sprinkler droplet size and velocity needed to calculate droplet kinetic energy have been developed and tested over the past 50 years, each with ad...

  5. 40 CFR Table F-5 to Subpart F of... - Estimated Mass Concentration Measurement of PM2.5 for Idealized “Typical” Coarse Aerosol Size...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 5 2011-07-01 2011-07-01 false Estimated Mass Concentration... 53—Estimated Mass Concentration Measurement of PM2.5 for Idealized “Typical” Coarse Aerosol Size Distribution Particle Aerodynamic Diameter (µm) Test Sampler Fractional Sampling Effectiveness Interval Mass...

  6. 40 CFR Table F-5 to Subpart F of... - Estimated Mass Concentration Measurement of PM2.5 for Idealized “Typical” Coarse Aerosol Size...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 5 2010-07-01 2010-07-01 false Estimated Mass Concentration... 53—Estimated Mass Concentration Measurement of PM2.5 for Idealized “Typical” Coarse Aerosol Size Distribution Particle Aerodynamic Diameter (µm) Test Sampler Fractional Sampling Effectiveness Interval Mass...

  7. Hanbury–Brown–Twiss measurements at large rapidity separations, or can we measure the proton radius in p-A collisions?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Altinoluk, Tolga; Armesto, Néstor; Beuf, Guillaume

    2015-11-14

    We point out that current calculations of inclusive two-particle correlations in p-A collisions based on the Color Glass Condensate approach exhibit a contribution from Hanbury–Brown–Twiss correlations. These HBT correlations are quite distinct from the standard ones, in that they are apparent for particles widely separated in rapidity. The transverse size of the emitter which is reflected in these correlations is the gluonic size of the proton. Furthermore, this raises an interesting possibility of measuring the proton size directly by the HBT effect of particle pairs produced in p-A collisions.

  8. Estimating Patient Dose from X-ray Tube Output Metrics: Automated Measurement of Patient Size from CT Images Enables Large-scale Size-specific Dose Estimates

    PubMed Central

    Ikuta, Ichiro; Warden, Graham I.; Andriole, Katherine P.; Khorasani, Ramin

    2014-01-01

    Purpose To test the hypothesis that patient size can be accurately calculated from axial computed tomographic (CT) images, including correction for the effects of anatomy truncation that occur in routine clinical CT image reconstruction. Materials and Methods Institutional review board approval was obtained for this HIPAA-compliant study, with waiver of informed consent. Water-equivalent diameter (DW) was computed from the attenuation-area product of each image within 50 adult CT scans of the thorax and of the abdomen and pelvis and was also measured for maximal field of view (FOV) reconstructions. Linear regression models were created to compare DW with the effective diameter (Deff) used to select size-specific volume CT dose index (CTDIvol) conversion factors as defined in report 204 of the American Association of Physicists in Medicine. Linear regression models relating reductions in measured DW to a metric of anatomy truncation were used to compensate for the effects of clinical image truncation. Results In the thorax, DW versus Deff had an R2 of 0.51 (n = 200, 50 patients at four anatomic locations); in the abdomen and pelvis, R2 was 0.90 (n = 150, 50 patients at three anatomic locations). By correcting for image truncation, the proportion of clinically reconstructed images with an extracted DW within ±5% of the maximal FOV DW increased from 54% to 90% in the thorax (n = 3602 images) and from 95% to 100% in the abdomen and pelvis (6181 images). Conclusion The DW extracted from axial CT images is a reliable measure of patient size, and varying degrees of clinical image truncation can be readily corrected. Automated measurement of patient size combined with CT radiation exposure metrics may enable patient-specific dose estimation on a large scale. © RSNA, 2013 PMID:24086075

  9. Attention changes perceived size of moving visual patterns.

    PubMed

    Anton-Erxleben, Katharina; Henrich, Christian; Treue, Stefan

    2007-08-23

    Spatial attention shifts receptive fields in monkey extrastriate visual cortex toward the focus of attention (S. Ben Hamed, J. R. Duhamel, F. Bremmer, & W. Graf, 2002; C. E. Connor, J. L. Gallant, D. C. Preddie, & D. C. Van Essen, 1996; C. E. Connor, D. C. Preddie, J. L. Gallant, & D. C. Van Essen, 1997; T. Womelsdorf, K. Anton-Erxleben, F. Pieper, & S. Treue, 2006). This distortion in the retinotopic distribution of receptive fields might cause distortions in spatial perception such as an increase of the perceived size of attended stimuli. Here we test for such an effect in human subjects by measuring the point of subjective equality (PSE) for the perceived size of a neutral and an attended stimulus when drawing automatic attention to one of two spatial locations. We found a significant increase in perceived size of attended stimuli. Depending on the absolute stimulus size, this effect ranged from 4% to 12% and was more pronounced for smaller than for larger stimuli. In our experimental design, an attentional effect on task difficulty or a cue bias might influence the PSE measure. We performed control experiments and indeed found such effects, but they could only account for part of the observed results. Our findings demonstrate that the allocation of transient spatial attention onto a visual stimulus increases its perceived size and additionally biases subjects to select this stimulus for a perceptual judgment.

  10. Thermal diffusivity measurement for urchin-like gold nanofluids with different solvents, sizes and concentrations/shapes.

    PubMed

    López-Muñoz, Gerardo A; Balderas-López, José Abraham; Ortega-Lopez, Jaime; Pescador-Rojas, José A; Salazar, Jaime Santoyo

    2012-12-06

    The thermal properties of nanofluids are an especially interesting research topic because of the variety of potential applications, which range from bio-utilities to next-generation heat-transfer fluids. In this study, photopyroelectric calorimetry for measuring the thermal diffusivity of urchin-like colloidal gold nanofluids as a function of particle size, concentration and shape in water, ethanol and ethylene glycol is reported. Urchin-like gold nanoparticles were synthesised in the presence of hydroquinone through seed-mediated growth with homogeneous shape and size ranging from 55 to 115 nm. The optical response, size and morphology of these nanoparticles were characterised using UV-visible spectroscopy and transmission electron microscopy. The thermal diffusivity of these nanofluids decreased as the size of the nanoparticles increased, and the enhancement depended on the thermal diffusivity of the solvent. The opposite effect (increase in thermal diffusivity) was observed when the nanoparticle concentration was increased. These effects were more evident for urchin-like gold nanofluids than for the corresponding spherical gold nanofluids.

  11. Laboratory evaluation of the Sequoia Scientific LISST-ABS acoustic backscatter sediment sensor

    USGS Publications Warehouse

    Snazelle, Teri T.

    2017-12-18

    Sequoia Scientific’s LISST-ABS is an acoustic backscatter sensor designed to measure suspended-sediment concentration at a point source. Three LISST-ABS were evaluated at the U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF). Serial numbers 6010, 6039, and 6058 were assessed for accuracy in solutions with varying particle-size distributions and for the effect of temperature on sensor accuracy. Certified sediment samples composed of different ranges of particle size were purchased from Powder Technology Inc. These sediment samples were 30–80-micron (µm) Arizona Test Dust; less than 22-µm ISO 12103-1, A1 Ultrafine Test Dust; and 149-µm MIL-STD 810E Silica Dust. The sensor was able to accurately measure suspended-sediment concentration when calibrated with sediment of the same particle-size distribution as the measured. Overall testing demonstrated that sensors calibrated with finer sized sediments overdetect sediment concentrations with coarser sized sediments, and sensors calibrated with coarser sized sediments do not detect increases in sediment concentrations from small and fine sediments. These test results are not unexpected for an acoustic-backscatter device and stress the need for using accurate site-specific particle-size distributions during sensor calibration. When calibrated for ultrafine dust with a less than 22-µm particle size (silt) and with the Arizona Test Dust with a 30–80-µm range, the data from sensor 6039 were biased high when fractions of the coarser (149-µm) Silica Dust were added. Data from sensor 6058 showed similar results with an elevated response to coarser material when calibrated with a finer particle-size distribution and a lack of detection when subjected to finer particle-size sediment. Sensor 6010 was also tested for the effect of dissimilar particle size during the calibration and showed little effect. Subsequent testing revealed problems with this sensor, including an inadequate temperature compensation, making this data questionable. The sensor was replaced by Sequoia Scientific with serial number 6039. Results from the extended temperature testing showed proper temperature compensation for sensor 6039, and results from the dissimilar calibration/testing particle-size distribution closely corroborated the results from sensor 6058.

  12. Power and money in cluster randomized trials: when is it worth measuring a covariate?

    PubMed

    Moerbeek, Mirjam

    2006-08-15

    The power to detect a treatment effect in cluster randomized trials can be increased by increasing the number of clusters. An alternative is to include covariates into the regression model that relates treatment condition to outcome. In this paper, formulae are derived in order to evaluate both strategies on basis of their costs. It is shown that the strategy that uses covariates is more cost-efficient in detecting a treatment effect when the costs to measure these covariates are small and the correlation between the covariates and outcome is sufficiently large. The minimum required correlation depends on the cluster size, and the costs to recruit a cluster and to measure the covariate, relative to the costs to recruit a person. Measuring a covariate that varies at the person level only is recommended when cluster sizes are small and the costs to recruit and measure a cluster are large. Measuring a cluster level covariate is recommended when cluster sizes are large and the costs to recruit and measure a cluster are small. An illustrative example shows the use of the formulae in a practical setting. Copyright 2006 John Wiley & Sons, Ltd.

  13. Measuring the effect of spray plume angle on the accuracy of droplet size data

    USDA-ARS?s Scientific Manuscript database

    Analysis of droplet size data using laser diffraction allows for quick and easy assessment of droplet size for agricultural spray nozzles and pesticides; however, operation and setup of the instrument and test system can potentially influence the accuracy of the data. One of the factors is the orie...

  14. Enhancement of fluorescence intensity by silicon particles and its size effect.

    PubMed

    Saitow, Ken-ichi; Suemori, Hidemi; Tamamitsu, Hironori

    2014-02-04

    Fluorescence-intensity enhancement of dye molecules was investigated using silicon submicron particles as a function of the particle size. Silicon particles with a size of 500 nm gave an enhancement factor up to 180. Measurement of scattering spectra revealed that the localized electric field at the particle enhances the fluorescence intensity.

  15. Effect of fluorescent particle size on the modulation efficiency of ultrasound-modulated fluorescence.

    PubMed

    Liu, Yuan; Yuan, Baohong; Vignola, Joseph

    2012-01-01

    To investigate whether the size of fluorescent particles affects the modulation efficiency of ultrasound-modulated fluorescence (UMF), we measured UMF and DC (direct current) signals of the fluorescence emission from four different sized fluorescent particles: (1) three carboxylate-modified fluorescent microspheres (FM) with diameters of 20 nm, 200 nm, and 1.0 µm and (2) streptavidin-conjugated Alexa Fluor 647 with a diameter of approximately 5 nm. The UMF and DC signals were simultaneously measured using a broadband lock-in amplifier and a narrowband amplifier, respectively. The ratio of the UMF strength to the DC signal strength is defined as the modulation efficiency. This modulation efficiency was then used to evaluate the effects of fluorophore size and concentration. Results show that the modulation efficiency was improved by approximately a factor of two when the size of the fluorescent particles is increased from 5 nm to 1 µm. In addition, the linear relationship between the UMF strength and ultrasound pressure (observed in our previous study) were maintained regardless of the fluorescent particle sizes.

  16. Effect of fluorescent particle size on the modulation efficiency of ultrasound-modulated fluorescence

    PubMed Central

    Liu, Yuan; Yuan, Baohong; Vignola, Joseph

    2013-01-01

    To investigate whether the size of fluorescent particles affects the modulation efficiency of ultrasound-modulated fluorescence (UMF), we measured UMF and DC (direct current) signals of the fluorescence emission from four different sized fluorescent particles: (1) three carboxylate-modified fluorescent microspheres (FM) with diameters of 20 nm, 200 nm, and 1.0 µm and (2) streptavidin-conjugated Alexa Fluor 647 with a diameter of approximately 5 nm. The UMF and DC signals were simultaneously measured using a broadband lock-in amplifier and a narrowband amplifier, respectively. The ratio of the UMF strength to the DC signal strength is defined as the modulation efficiency. This modulation efficiency was then used to evaluate the effects of fluorophore size and concentration. Results show that the modulation efficiency was improved by approximately a factor of two when the size of the fluorescent particles is increased from 5 nm to 1 µm. In addition, the linear relationship between the UMF strength and ultrasound pressure (observed in our previous study) were maintained regardless of the fluorescent particle sizes. PMID:24179476

  17. Plant canopy gap-size analysis theory for improving optical measurements of leaf-area index

    NASA Astrophysics Data System (ADS)

    Chen, Jing M.; Cihlar, Josef

    1995-09-01

    Optical instruments currently available for measuring the leaf-area index (LAI) of a plant canopy all utilize only the canopy gap-fraction information. These instruments include the Li-Cor LAI-2000 Plant Canopy Analyzer, Decagon, and Demon. The advantages of utilizing both the canopy gap-fraction and gap-size information are shown. For the purpose of measuring the canopy gap size, a prototype sunfleck-LAI instrument named Tracing Radiation and Architecture of Canopies (TRAC), has been developed and tested in two pure conifer plantations, red pine (Pinus resinosa Ait.) and jack pine (Pinus banksiana Lamb). A new gap-size-analysis theory is presented to quantify the effect of canopy architecture on optical measurements of LAI based on the gap-fraction principle. The theory is an improvement on that of Lang and Xiang [Agric. For. Meteorol. 37, 229 (1986)]. In principle, this theory can be used for any heterogeneous canopies.

  18. Cognitive and Occupational Function in Survivors of Adolescent Cancer.

    PubMed

    Nugent, Bethany D; Bender, Catherine M; Sereika, Susan M; Tersak, Jean M; Rosenzweig, Margaret

    2018-02-01

    Adolescents with cancer have unique developmental considerations. These include brain development, particularly in the frontal lobe, and a focus on completing education and entering the workforce. Cancer and treatment at this stage may prove to uniquely affect survivors' experience of cognitive and occupational function. An exploratory, cross-sectional, descriptive comparative study was employed to describe cognitive and occupational function in adult survivors of adolescent cancer (diagnosed between the ages of 15 and 21 years) and explore differences in age- and gender-matched controls. In total, 23 survivors and 14 controls participated in the study. While significant differences were not found between the groups on measures of cognitive and occupational function, several small and medium effect sizes were found suggesting that survivors may have greater difficulty than controls. Two small effect sizes were found in measures of neuropsychological performance (the Digit Vigilance test [d = 0.396] and Stroop test [d = 0.226]). Small and medium effect sizes ranging from 0.269 to 0.605 were found for aspects of perceived and total cognitive function. A small effect size was also found in work output (d = 0.367). While we did not find significant differences in cognitive or occupational function between survivors and controls, the effect sizes observed point to the need for future research. Future work using a larger sample size and longitudinal design are needed to further explore cognitive and occupational function in this vulnerable and understudied population and assist in the understanding of patterns of change over time.

  19. Size effects under homogeneous deformation of single crystals: A discrete dislocation analysis

    NASA Astrophysics Data System (ADS)

    Guruprasad, P. J.; Benzerga, A. A.

    Mechanism-based discrete dislocation plasticity is used to investigate the effect of size on micron scale crystal plasticity under conditions of macroscopically homogeneous deformation. Long-range interactions among dislocations are naturally incorporated through elasticity. Constitutive rules are used which account for key short-range dislocation interactions. These include junction formation and dynamic source and obstacle creation. Two-dimensional calculations are carried out which can handle high dislocation densities and large strains up to 0.1. The focus is laid on the effect of dimensional constraints on plastic flow and hardening processes. Specimen dimensions ranging from hundreds of nanometers to tens of microns are considered. Our findings show a strong size-dependence of flow strength and work-hardening rate at the micron scale. Taylor-like hardening is shown to be insufficient as a rationale for the flow stress scaling with specimen dimensions. The predicted size effect is associated with the emergence, at sufficient resolution, of a signed dislocation density. Heuristic correlations between macroscopic flow stress and macroscopic measures of dislocation density are sought. Most accurate among those is a correlation based on two state variables: the total dislocation density and an effective, scale-dependent measure of signed density.

  20. Measuring the effect of attention on simple visual search.

    PubMed

    Palmer, J; Ames, C T; Lindsey, D T

    1993-02-01

    Set-size in visual search may be due to 1 or more of 3 factors: sensory processes such as lateral masking between stimuli, attentional processes limiting the perception of individual stimuli, or attentional processes affecting the decision rules for combining information from multiple stimuli. These possibilities were evaluated in tasks such as searching for a longer line among shorter lines. To evaluate sensory contributions, display set-size effects were compared with cuing conditions that held sensory phenomena constant. Similar effects for the display and cue manipulations suggested that sensory processes contributed little under the conditions of this experiment. To evaluate the contribution of decision processes, the set-size effects were modeled with signal detection theory. In these models, a decision effect alone was sufficient to predict the set-size effects without any attentional limitation due to perception.

  1. Confounding compression: the effects of posture, sizing and garment type on measured interface pressure in sports compression clothing.

    PubMed

    Brophy-Williams, Ned; Driller, Matthew William; Shing, Cecilia Mary; Fell, James William; Halson, Shona Leigh; Halson, Shona Louise

    2015-01-01

    The purpose of this investigation was to measure the interface pressure exerted by lower body sports compression garments, in order to assess the effect of garment type, size and posture in athletes. Twelve national-level boxers were fitted with sports compression garments (tights and leggings), each in three different sizes (undersized, recommended size and oversized). Interface pressure was assessed across six landmarks on the lower limb (ranging from medial malleolus to upper thigh) as athletes assumed sitting, standing and supine postures. Sports compression leggings exerted a significantly higher mean pressure than sports compression tights (P < 0.001). Oversized tights applied significantly less pressure than manufacturer-recommended size or undersized tights (P < 0.001), yet no significant differences were apparent between different-sized leggings. Standing posture resulted in significantly higher mean pressure application than a seated posture for both tights and leggings (P < 0.001 and P = 0.002, respectively). Pressure was different across landmarks, with analyses revealing a pressure profile that was neither strictly graduated nor progressive in nature. The pressure applied by sports compression garments is significantly affected by garment type, size and posture assumed by the wearer.

  2. Effects of Styrene-Acrylic Sizing on the Mechanical Properties of Carbon Fiber Thermoplastic Towpregs and Their Composites.

    PubMed

    Bowman, Sean; Jiang, Qiuran; Memon, Hafeezullah; Qiu, Yiping; Liu, Wanshuang; Wei, Yi

    2018-03-01

    Thermoplastic towpregs are convenient and scalable raw materials for the fabrication of continuous fiber-reinforced thermoplastic matrix composites. In this paper, the potential to employ epoxy and styrene-acrylic sizing agents was evaluated for the making of carbon fiber thermoplastic towpregs via a powder-coating method. The protective effects and thermal stability of these sizing agents were investigated by single fiber tensile test and differential scanning calorimetry (DSC) measurement. The results indicate that the epoxy sizing agent provides better protection to carbon fibers, but it cannot be used for thermoplastic towpreg processing due to its poor chemical stability at high temperature. The bending rigidity of the tows and towpregs with two styrene-acrylic sizing agents was measured by cantilever and Kawabata methods. The styrene-acrylic sized towpregs show low torque values, and are suitable for further processing, such as weaving, preforming, and winding. Finally, composite panels were fabricated directly from the towpregs by hot compression molding. Both of the composite panels show superior flexural strength (>400 MPa), flexural modulus (>63 GPa), and interlaminar shear strength (>27 MPa), indicating the applicability of these two styrene-acrylic sizing agents for carbon fiber thermoplastic towpregs.

  3. How do different data logger sizes and attachment positions affect the diving behaviour of little penguins?

    NASA Astrophysics Data System (ADS)

    Ropert-Coudert, Yan; Knott, Nathan; Chiaradia, André; Kato, Akiko

    2007-02-01

    It is crucial in any bio-logging study to establish the potential effect that attachment of loggers may have on the animal. This ensures that the behaviour monitored by the loggers has a biological relevance, as well as for ethical reasons. Evaluation of the effects of externally attached loggers shows that they increase the drag of swimming animals and increase their energy expenditure. Nevertheless, little research has been done on the effects of size or position of such loggers. In this study, we tested whether the size (i.e. large: 4.9% versus small: 3.4% of the bird's frontal area) or the place of attachment (middle versus lower back) affected the diving behaviour of male and female little penguins ( Eudyptula minor). The positioning of the data logger on the middle or lower section of little penguins' back had little, if no effect, on the diving variables measured in this study. Size of the loggers, however, had strong effects. Birds with large loggers made shorter dives and reached shallower depths than those with small loggers. In addition, birds with large loggers made more dives probably to compensate for the extra cost of carrying a large logger. The measured variables also differed between the sexes, with males diving deeper and longer than females. Logger size had a sex-specific effect on the trip duration and descent speed, with males equipped with large loggers staying longer at sea than those with small loggers, and females with large loggers descending faster than those with small loggers. From our results, it appears that effects of logger position do not exist or are very small in comparison with the effects of logger size. The results of the current study indicate that the effects of size of loggers be evaluated more commonly in bio-logging research into the diving activity of free-ranging birds.

  4. Ferroelectric size effects in multiferroic BiFeO3 thin films

    NASA Astrophysics Data System (ADS)

    Chu, Y. H.; Zhao, T.; Cruz, M. P.; Zhan, Q.; Yang, P. L.; Martin, L. W.; Huijben, M.; Yang, C. H.; Zavaliche, F.; Zheng, H.; Ramesh, R.

    2007-06-01

    Ferroelectric size effects in multiferroic BiFeO3 have been studied using a host of complementary measurements. The structure of such epitaxial films has been investigated using atomic force microscopy, transmission electron microscopy, and x-ray diffraction. The crystal structure of the films has been identified as a monoclinic phase, which suggests that the polarization direction is close to ⟨111⟩. Such behavior has also been confirmed by piezoforce microscopy measurements. That also reveals that the ferroelectricity is down to at least 2nm.

  5. Screening study of four environmentally relevant microplastic pollutants: Uptake and effects on Daphnia magna and Artemia franciscana.

    PubMed

    Kokalj, Anita Jemec; Kunej, Urban; Skalar, Tina

    2018-06-08

    This study investigated four different environmentally relevant microplastic (MP) pollutants which were derived from two facial cleansers, a plastic bag and polyethylene textile fleece. The mean size range of the particles (according to number distribution) was 20-250 μm when measured as a powder and 0.02-200 μm in suspension. In all MP exposures, plastic particles were found inside the guts of D. magna and A. franciscana, but only in the case of daphnids a clear exponential correlation between MP uptake in the gut and the size of the MP was identified. Exposure tests in which the majority of the MP particles were below 100 μm in size also had higher numbers of daphnids displaying evidence of MP ingestion. As the average MP particle size increased, the percentage of daphnids which had MP in their gut decreased. Using a number distribution value to measure particle size when in a suspension is more experimentally relevant as it provides a more realistic particle size than when samples are measured as a powder. Generally, artemias had fewer MP particles in the gut, than the daphnids, which could be explained by their different food size preferences. No acute effects on D. magna were found, but the growth of A. franciscana was affected. We conclude that zooplankton crustacean can ingest various MPs but none of the exposures tested were highly acutely hazardous to the test species. In addition, no delayed lethal effects in a 24 h post-exposure period were found. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Biofuel manufacturing from woody biomass: effects of sieve size used in biomass size reduction.

    PubMed

    Zhang, Meng; Song, Xiaoxu; Deines, T W; Pei, Z J; Wang, Donghai

    2012-01-01

    Size reduction is the first step for manufacturing biofuels from woody biomass. It is usually performed using milling machines and the particle size is controlled by the size of the sieve installed on a milling machine. There are reported studies about the effects of sieve size on energy consumption in milling of woody biomass. These studies show that energy consumption increased dramatically as sieve size became smaller. However, in these studies, the sugar yield (proportional to biofuel yield) in hydrolysis of the milled woody biomass was not measured. The lack of comprehensive studies about the effects of sieve size on energy consumption in biomass milling and sugar yield in hydrolysis process makes it difficult to decide which sieve size should be selected in order to minimize the energy consumption in size reduction and maximize the sugar yield in hydrolysis. The purpose of this paper is to fill this gap in the literature. In this paper, knife milling of poplar wood was conducted using sieves of three sizes (1, 2, and 4 mm). Results show that, as sieve size increased, energy consumption in knife milling decreased and sugar yield in hydrolysis increased in the tested range of particle sizes.

  7. Reproducibility and responsiveness of quality of life assessment and six minute walk test in elderly heart failure patients.

    PubMed

    O'Keeffe, S T; Lye, M; Donnellan, C; Carmichael, D N

    1998-10-01

    To examine the reproducibility and responsiveness to change of a six minute walk test and a quality of life measure in elderly patients with heart failure. Longitudinal within patient study. 60 patients with heart failure (mean age 82 years) attending a geriatric outpatient clinic, 45 of whom underwent a repeat assessment three to eight weeks later. Subjects underwent a standardised six minute walk test and completed the chronic heart failure questionnaire (CHQ), a heart failure specific quality of life questionnaire. Intraclass correlation coefficients (ICC) were calculated using a random effects one way analysis of variance as a measure of reproducibility. Guyatt's responsiveness coefficient and effect sizes were calculated as measures of responsiveness to change. 24 patients reported no major change in cardiac status, while seven had deteriorated and 14 had improved between the two clinic visits. Reproducibility was satisfactory (ICC > 0.75) for the six minute walk test, for the total CHQ score, and for the dyspnoea, fatigue, and emotion domains of the CHQ. Effect sizes for all measures were large (> 0.8), and responsiveness coefficients were very satisfactory (> 0.7). Effect sizes for detecting deterioration were greater than those for detecting improvement. Quality of life assessment and a six minute walk test are reproducible and responsive measures of cardiac status in frail, very elderly patients with heart failure.

  8. Measurement of inflammation in man and animals by radiometry.

    PubMed

    Collins, A J; Ring, E F

    1972-01-01

    1. A radiometer is described, which is sensitive to infrared radiation in the range 0-25 mum, and which, after calibration with a black body standard can be used as a non-contact, fast reading thermometer.2. An example of acute joint inflammation in a patient with rheumatoid arthritis is described. The temperatures over the joint measured by radiometry, followed inflammatory changes in the joint effusion.3. Using rats, the method of measuring inflammation by radiometry was compared with measurements of increase in joint size. Changes measured by radiometry preceded changes shown by increase in joint size.4. The radiometer method was able to demonstrate the effect of an anti-inflammatory drug, given orally, against carrageenin inflammation.5. The procedure was found to be an accurate means of measuring inflammation and the anti-inflammatory effects of drugs. It was faster and less tedious than the other methods for the quantitative measurement of inflammation in man and animals.

  9. Impact of ageing on problem size and proactive interference in arithmetic facts solving.

    PubMed

    Archambeau, Kim; De Visscher, Alice; Noël, Marie-Pascale; Gevers, Wim

    2018-02-01

    Arithmetic facts (AFs) are required when solving problems such as "3 × 4" and refer to calculations for which the correct answer is retrieved from memory. Currently, two important effects that modulate the performance in AFs have been highlighted: the problem size effect and the proactive interference effect. The aim of this study is to investigate possible age-related changes of the problem size effect and the proactive interference effect in AF solving. To this end, the performance of young and older adults was compared in a multiplication production task. Furthermore, an independent measure of proactive interference was assessed to further define the architecture underlying this effect in multiplication solving. The results indicate that both young and older adults were sensitive to the effects of interference and of the problem size. That is, both interference and problem size affected performance negatively: the time needed to solve a multiplication problem increases as the level of interference and the size of the problem increase. Regarding the effect of ageing, the problem size effect remains constant with age, indicating a preserved AF network in older adults. Interestingly, sensitivity to proactive interference in multiplication solving was less pronounced in older than in younger adults suggesting that part of the proactive interference has been overcome with age.

  10. Quantitative study of bundle size effect on thermal conductivity of single-walled carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Feng, Ya; Inoue, Taiki; An, Hua; Xiang, Rong; Chiashi, Shohei; Maruyama, Shigeo

    2018-05-01

    Compared with isolated single-walled carbon nanotubes (SWNTs), thermal conductivity is greatly impeded in SWNT bundles; however, the measurement of the bundle size effect is difficult. In this study, the number of SWNTs in a bundle was determined based on the transferred horizontally aligned SWNTs on a suspended micro-thermometer to quantitatively study the effect of the bundle size on thermal conductivity. Increasing the bundle size significantly degraded the thermal conductivity. For isolated SWNTs, thermal conductivity was approximately 5000 ± 1000 W m-1 K-1 at room temperature, three times larger than that of the four-SWNT bundle. The logarithmical deterioration of thermal conductivity resulting from the increased bundle size can be attributed to the increased scattering rate with neighboring SWNTs based on the kinetic theory.

  11. Single-case synthesis tools II: Comparing quantitative outcome measures.

    PubMed

    Zimmerman, Kathleen N; Pustejovsky, James E; Ledford, Jennifer R; Barton, Erin E; Severini, Katherine E; Lloyd, Blair P

    2018-03-07

    Varying methods for evaluating the outcomes of single case research designs (SCD) are currently used in reviews and meta-analyses of interventions. Quantitative effect size measures are often presented alongside visual analysis conclusions. Six measures across two classes-overlap measures (percentage non-overlapping data, improvement rate difference, and Tau) and parametric within-case effect sizes (standardized mean difference and log response ratio [increasing and decreasing])-were compared to determine if choice of synthesis method within and across classes impacts conclusions regarding effectiveness. The effectiveness of sensory-based interventions (SBI), a commonly used class of treatments for young children, was evaluated. Separately from evaluations of rigor and quality, authors evaluated behavior change between baseline and SBI conditions. SBI were unlikely to result in positive behavior change across all measures except IRD. However, subgroup analyses resulted in variable conclusions, indicating that the choice of measures for SCD meta-analyses can impact conclusions. Suggestions for using the log response ratio in SCD meta-analyses and considerations for understanding variability in SCD meta-analysis conclusions are discussed. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Within-Group Effect-Size Benchmarks for Problem-Solving Therapy for Depression in Adults

    ERIC Educational Resources Information Center

    Rubin, Allen; Yu, Miao

    2017-01-01

    This article provides benchmark data on within-group effect sizes from published randomized clinical trials that supported the efficacy of problem-solving therapy (PST) for depression among adults. Benchmarks are broken down by type of depression (major or minor), type of outcome measure (interview or self-report scale), whether PST was provided…

  13. The Hard but Necessary Task of Gathering Order-One Effect Size Indices in Meta-Analysis

    ERIC Educational Resources Information Center

    Ortego, Carmen; Botella, Juan

    2010-01-01

    Meta-analysis of studies with two groups and two measurement occasions must employ order-one effect size indices to represent study outcomes. Especially with non-random assignment, non-equivalent control group designs, a statistical analysis restricted to post-treatment scores can lead to severely biased conclusions. The 109 primary studies…

  14. Are Parents' Gender Schemas Related to Their Children's Gender-Related Cognitions? A Meta-Analysis.

    ERIC Educational Resources Information Center

    Tenenbaum, Harriet R.; Leaper, Campbell

    2002-01-01

    Used meta-analysis to examine relationship of parents' gender schemas and their offspring's gender-related cognitions, with samples ranging in age from infancy through early adulthood. Found a small but meaningful effect size (r=.16) indicating a positive correlation between parent gender schema and offspring measures. Effect sizes were influenced…

  15. Confidence Intervals for Effect Sizes: Compliance and Clinical Significance in the "Journal of Consulting and Clinical Psychology"

    ERIC Educational Resources Information Center

    Odgaard, Eric C.; Fowler, Robert L.

    2010-01-01

    Objective: In 2005, the "Journal of Consulting and Clinical Psychology" ("JCCP") became the first American Psychological Association (APA) journal to require statistical measures of clinical significance, plus effect sizes (ESs) and associated confidence intervals (CIs), for primary outcomes (La Greca, 2005). As this represents the single largest…

  16. Aggregate and Individual Replication Probability within an Explicit Model of the Research Process

    ERIC Educational Resources Information Center

    Miller, Jeff; Schwarz, Wolf

    2011-01-01

    We study a model of the research process in which the true effect size, the replication jitter due to changes in experimental procedure, and the statistical error of effect size measurement are all normally distributed random variables. Within this model, we analyze the probability of successfully replicating an initial experimental result by…

  17. Depicted serving size: cereal packaging pictures exaggerate serving sizes and promote overserving.

    PubMed

    Tal, Aner; Niemann, Stina; Wansink, Brian

    2017-02-06

    Extensive work has focused on the effects of nutrition label information on consumer behavior on the one hand, and on the effects of packaging graphics on the other hand. However, little work has examined how serving suggestion depictions - graphics relating to serving size - influence the quantity consumers serve themselves. The current work examines the prevalence of exaggerated serving size depictions on product packaging (study 1) and its effects on food serving in the context of cereal (study 2). Study 1 was an observational field survey of cereal packaging. Study 2 was a mixed experimental cross-sectional design conducted at a U.S. university, with 51 student participants. Study 1 coded 158 US breakfast cereals and compared the serving sizes depicted on the front of the box with the suggested serving size stated on the nutrition facts panel. Study 2 measured the amount of cereal poured from exaggerated or accurate serving size depictions. Study 1 compared average servings via t-tests. Study 2 used a mixed model with cereal type as the repeated measure and a compound symmetry covariance matrix. Study 1 demonstrated that portion size depictions on the front of 158 cereal boxes were 65.84% larger (221 vs. 134 calories) than the recommended portions on nutrition facts panels of those cereals. Study 2 showed that boxes that depicted exaggerated serving sizes led people to pour 20% more cereal compared to pouring from modified boxes that depicted a single-size portion of cereal matching suggested serving size. This was 45% over the suggested serving size. Biases in depicted serving size depicted on cereal packaging are prevalent in the marketplace. Such biases may lead to overserving, which may consequently lead to overeating. Companies should depict the recommended serving sizes, or otherwise indicate that the depicted portion represents an exaggerated serving size.

  18. Men, women…who cares? A population-based study on sex differences and gender roles in empathy and moral cognition.

    PubMed

    Baez, Sandra; Flichtentrei, Daniel; Prats, María; Mastandueno, Ricardo; García, Adolfo M; Cetkovich, Marcelo; Ibáñez, Agustín

    2017-01-01

    Research on sex differences in empathy has revealed mixed findings. Whereas experimental and neuropsychological measures show no consistent sex effect, self-report data consistently indicates greater empathy in women. However, available results mainly come from separate populations with relatively small samples, which may inflate effect sizes and hinder comparability between both empirical corpora. To elucidate the issue, we conducted two large-scale studies. First, we examined whether sex differences emerge in a large population-based sample (n = 10,802) when empathy is measured with an experimental empathy-for-pain paradigm. Moreover, we investigated the relationship between empathy and moral judgment. In the second study, a subsample (n = 334) completed a self-report empathy questionnaire. Results showed some sex differences in the experimental paradigm, but with minuscule effect sizes. Conversely, women did portray themselves as more empathic through self-reports. In addition, utilitarian responses to moral dilemmas were less frequent in women, although these differences also had small effect sizes. These findings suggest that sex differences in empathy are highly driven by the assessment measure. In particular, self-reports may induce biases leading individuals to assume gender-role stereotypes. Awareness of the role of measurement instruments in this field may hone our understanding of the links between empathy, sex differences, and gender roles.

  19. Do impression management and self-deception distort self-report measures with content of dynamic risk factors in offender samples? A meta-analytic review.

    PubMed

    Hildebrand, Martin; Wibbelink, Carlijn J M; Verschuere, Bruno

    Self-report measures provide an important source of information in correctional/forensic settings, yet at the same time the validity of that information is often questioned because self-reports are thought to be highly vulnerable to self-presentation biases. Primary studies in offender samples have provided mixed results with regard to the impact of socially desirable responding on self-reports. The main aim of the current study was therefore to investigate-via a meta-analytic review of published studies-the association between the two dimensions of socially desirable responding, impression management and self-deceptive enhancement, and self-report measures with content of dynamic risk factors using the Balanced Inventory of Desirable Responding (BIDR) in offender samples. These self-report measures were significantly and negatively related with self-deception (r = -0.120, p < 0.001; k = 170 effect sizes) and impression management (r = -0.158, p < 0.001; k = 157 effect sizes), yet there was evidence of publication bias for the impression management effect with the trim and fill method indicating that the relation is probably even smaller (r = -0.07). The magnitude of the effect sizes was small. Moderation analyses suggested that type of dynamic risk factor (e.g., antisocial cognition versus antisocial personality), incentives, and publication year affected the relationship between impression management and self-report measures with content of dynamic risk factors, whereas sample size, setting (e.g., incarcerated, community), and publication year influenced the relation between self-deception and these self-report measures. The results indicate that the use of self-report measures to assess dynamic risk factors in correctional/forensic settings is not inevitably compromised by socially desirable responding, yet caution is warranted for some risk factors (antisocial personality traits), particularly when incentives are at play. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Size effects and electron microscopy of thin metal films. M.S. Thesis

    NASA Technical Reports Server (NTRS)

    Hernandez, J. D.

    1978-01-01

    All films were deposited by resistive heated evaporation in an oil diffusion pumped vacuum system (ultimate approx. equal to 0.0000001 torr). The growth from nuclei to a continuous film is highly dependent on the deposition parameters, evaporation rate as well as substrate material and substrate temperature. The growth stages of a film and the dependence of grain size on various deposition and annealing parameters are shown. Resistivity measurements were taken on thin films to observe size effects.

  1. ZnFe2O4 nanoparticles dispersed in a highly porous silica aerogel matrix: a magnetic study.

    PubMed

    Bullita, S; Casu, A; Casula, M F; Concas, G; Congiu, F; Corrias, A; Falqui, A; Loche, D; Marras, C

    2014-03-14

    We report the detailed structural characterization and magnetic investigation of nanocrystalline zinc ferrite nanoparticles supported on a silica aerogel porous matrix which differ in size (in the range 4-11 nm) and the inversion degree (from 0.4 to 0.2) as compared to bulk zinc ferrite which has a normal spinel structure. The samples were investigated by zero-field-cooling-field-cooling, thermo-remnant DC magnetization measurements, AC magnetization investigation and Mössbauer spectroscopy. The nanocomposites are superparamagnetic at room temperature; the temperature of the superparamagnetic transition in the samples decreases with the particle size and therefore it is mainly determined by the inversion degree rather than by the particle size, which would give an opposite effect on the blocking temperature. The contribution of particle interaction to the magnetic behavior of the nanocomposites decreases significantly in the sample with the largest particle size. The values of the anisotropy constant give evidence that the anisotropy constant decreases upon increasing the particle size of the samples. All these results clearly indicate that, even when dispersed with low concentration in a non-magnetic and highly porous and insulating matrix, the zinc ferrite nanoparticles show a magnetic behavior similar to that displayed when they are unsupported or dispersed in a similar but denser matrix, and with higher loading. The effective anisotropy measured for our samples appears to be systematically higher than that measured for supported zinc ferrite nanoparticles of similar size, indicating that this effect probably occurs as a consequence of the high inversion degree.

  2. Meta-Analysis With Complex Research Designs: Dealing With Dependence From Multiple Measures and Multiple Group Comparisons

    PubMed Central

    Scammacca, Nancy; Roberts, Greg; Stuebing, Karla K.

    2013-01-01

    Previous research has shown that treating dependent effect sizes as independent inflates the variance of the mean effect size and introduces bias by giving studies with more effect sizes more weight in the meta-analysis. This article summarizes the different approaches to handling dependence that have been advocated by methodologists, some of which are more feasible to implement with education research studies than others. A case study using effect sizes from a recent meta-analysis of reading interventions is presented to compare the results obtained from different approaches to dealing with dependence. Overall, mean effect sizes and variance estimates were found to be similar, but estimates of indexes of heterogeneity varied. Meta-analysts are advised to explore the effect of the method of handling dependence on the heterogeneity estimates before conducting moderator analyses and to choose the approach to dependence that is best suited to their research question and their data set. PMID:25309002

  3. Size-dependent magnetic anisotropy of PEG coated Fe3O4 nanoparticles; comparing two magnetization methods

    NASA Astrophysics Data System (ADS)

    Nayek, C.; Manna, K.; Imam, A. A.; Alqasrawi, A. Y.; Obaidat, I. M.

    2018-02-01

    Understanding the size dependent magnetic anisotropy of iron oxide nanoparticles is essential for the successful application of these nanoparticles in several technological and medical fields. PEG-coated iron oxide (Fe3O4) nanoparticles with core diameters of 12 nm, 15 nm, and 16 nm were synthesized by the usual co-precipitation method. The morphology and structure of the nanoparticles were investigated using transmission electron microscopy (TEM), high resolution transmission electron microscopy (HRTEM), selected area electron diffraction (SAED), and X-ray diffraction (XRD). Magnetic measurements were conducted using a SQUID. The effective magnetic anisotropy was calculated using two methods from the magnetization measurements. In the first method the zero-field-cooled magnetization versus temperature measurements were used at several applied magnetic fields. In the second method we used the temperature-dependent coercivity curves obtained from the zero-field-cooled magnetization versus magnetic field hysteresis loops. The role of the applied magnetic field on the effective magnetic anisotropy, calculated form the zero-field-cooled magnetization versus temperature measurements, was revealed. The size dependence of the effective magnetic anisotropy constant Keff obtained by the two methods are compared and discussed.

  4. Larger Stimuli Require Longer Processing Time for Perception.

    PubMed

    Kanai, Ryota; Dalmaijer, Edwin S; Sherman, Maxine T; Kawakita, Genji; Paffen, Chris L E

    2017-05-01

    The time it takes for a stimulus to reach awareness is often assessed by measuring reaction times (RTs) or by a temporal order judgement (TOJ) task in which perceived timing is compared against a reference stimulus. Dissociations of RT and TOJ have been reported earlier in which increases in stimulus intensity such as luminance intensity results in a decrease of RT, whereas perceived perceptual latency in a TOJ task is affected to a lesser degree. Here, we report that a simple manipulation of stimulus size has stronger effects on perceptual latency measured by TOJ than on motor latency measured by RT tasks. When participants were asked to respond to the appearance of a simple stimulus such as a luminance blob, the perceptual latency measured against a standard reference stimulus was up to 40 ms longer for a larger stimulus. In other words, the smaller stimulus was perceived to occur earlier than the larger one. RT on the other hand was hardly affected by size. The TOJ results were further replicated in a simultaneity judgement task, suggesting that the effects of size are not due to TOJ-specific response biases but more likely reflect an effect on perceived timing.

  5. Parental divorce, sibship size, family resources, and children's academic performance.

    PubMed

    Sun, Yongmin; Li, Yuanzhang

    2009-09-01

    Using data from 19,839 adolescents from the National Education Longitudinal Study, this study investigates whether the effects of parental divorce on adolescents' academic test performance vary by sibship size. Analyses show that the negative effect of divorce on adolescent performance attenuates as sibship size increases. On the other side of the interaction, the inverse relationship between sibship size and test performance is weaker in disrupted than in two-biological-parent families. Trends of such interactions are evident when sibship size is examined either as a continuous or a categorical measure. Finally, the observed interactions on adolescents' academic performance are completely explained by variations in parental financial, human, cultural, and social resources. In sum, this study underlines the importance of treating the effect of parental divorce as a variable and calls for more research to identify child and family features that may change the magnitude of such an effect.

  6. Particle sizes in Saturn's rings from UVIS stellar occultations 1. Variations with ring region

    NASA Astrophysics Data System (ADS)

    Colwell, J. E.; Esposito, L. W.; Cooney, J. H.

    2018-01-01

    The Cassini spacecraft's Ultraviolet Imaging Spectrograph (UVIS) includes a high speed photometer (HSP) that has observed stellar occultations by Saturn's rings with a radial resolution of ∼10 m. In the absence of intervening ring material, the time series of measurements by the HSP is described by Poisson statistics in which the variance equals the mean. The finite sizes of the ring particles occulting the star lead to a variance that is larger than the mean due to correlations in the blocking of photons due to finite particle size and due to random variations in the number of individual particles in each measurement area. This effect was first exploited by Showalter and Nicholson (1990) with the stellar occultation observed by Voyager 2. At a given optical depth, a larger excess variance corresponds to larger particles or clumps that results in greater variation of the signal from measurement to measurement. Here we present analysis of the excess variance in occultations observed by Cassini UVIS. We observe differences in the best-fitting particle size in different ring regions. The C ring plateaus show a distinctly smaller effective particle size, R, than the background C ring, while the background C ring itself shows a positive correlation between R and optical depth. The innermost 700 km of the B ring has a distribution of excess variance with optical depth that is consistent with the C ring ramp and C ring but not with the remainder of the B1 region. The Cassini Division, while similar to the C ring in spectral and structural properties, has different trends in effective particle size with optical depth. There are discrete jumps in R on either side of the Cassini Division ramp, while the C ring ramp shows a smooth transition in R from the C ring to the B ring. The A ring is dominated by self-gravity wakes whose shadow size depends on the occultation geometry. The spectral ;halo; regions around the strongest density waves in the A ring correspond to decreases in R. There is also a pronounced dip in R at the Mimas 5:3 bending wave corresponding to an increase in optical depth there, suggesting that at these waves small particles are liberated from clumps or self-gravity wakes leading to a reduction in effective particle size and an increase in optical depth.

  7. Object strength--an accurate measure for small objects that is insensitive to partial volume effects.

    PubMed

    Tofts, P S; Silver, N C; Barker, G J; Gass, A

    2005-07-01

    There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.

  8. Potential errors in relative dose measurements in kilovoltage photon beams due to polarity effects in plane-parallel ionisation chambers

    NASA Astrophysics Data System (ADS)

    Dowdell, S.; Tyler, M.; McNamara, J.; Sloan, K.; Ceylan, A.; Rinks, A.

    2016-12-01

    Plane-parallel ionisation chambers are regularly used to conduct relative dosimetry measurements for therapeutic kilovoltage beams during commissioning and routine quality assurance. This paper presents the first quantification of the polarity effect in kilovoltage photon beams for two types of commercially available plane-parallel ionisation chambers used for such measurements. Measurements were performed at various depths along the central axis in a solid water phantom and for different field sizes at 2 cm depth to determine the polarity effect for PTW Advanced Markus and Roos ionisation chambers (PTW-Freiburg, Germany). Data was acquired for kilovoltage beams between 100 kVp (half-value layer (HVL)  =  2.88 mm Al) and 250 kVp (HVL  =  2.12 mm Cu) and field sizes of 3-15 cm diameter for 30 cm focus-source distance (FSD) and 4  ×  4 cm2-20  ×  20 cm2 for 50 cm FSD. Substantial polarity effects, up to 9.6%, were observed for the Advanced Markus chamber compared to a maximum 0.5% for the Roos chamber. The magnitude of the polarity effect was observed to increase with field size and beam energy but was consistent with depth. The polarity effect is directly influenced by chamber design, with potentially large polarity effects for some plane-parallel ionisation chambers. Depending on the specific chamber used, polarity corrections may be required for output factor measurements of kilovoltage photon beams. Failure to account for polarity effects could lead to an incorrect dose being delivered to the patient.

  9. Physical capital and the embodied nature of income inequality: gender differences in the effect of body size on workers' incomes in Canada.

    PubMed

    Perks, Thomas

    2012-02-01

    This study assesses the effects of body size--measured using the body mass index--on the income attainment of female and male workers in Canada. Using data from a national representative sample of Canadians, multivariate analyses show that, for female workers, the body size-income relationship is negative. However, for male workers, the body size-income relationship is positive and nonlinear. Using Bourdieu's conceptualization of physical capital, and Shilling's extension of it, it is argued that these results are suggestive of the relative importance of body size to the production and continuation of gender income inequality in Canada.

  10. Effect of Temperature on the Size Distribution, Shell Properties, and Stability of Definity®.

    PubMed

    Shekhar, Himanshu; Smith, Nathaniel J; Raymond, Jason L; Holland, Christy K

    2018-02-01

    Physical characterization of an ultrasound contrast agent (UCA) aids in its safe and effective use in diagnostic and therapeutic applications. The goal of this study was to investigate the impact of temperature on the size distribution, shell properties, and stability of Definity ® , a U.S. Food and Drug Administration-approved UCA used for left ventricular opacification. A Coulter counter was modified to enable particle size measurements at physiologic temperatures. The broadband acoustic attenuation spectrum and size distribution of Definity ® were measured at room temperature (25 °C) and physiologic temperature (37 °C) and were used to estimate the viscoelastic shell properties of the agent at both temperatures. Attenuation and size distribution was measured over time to assess the effect of temperature on the temporal stability of Definity ® . The attenuation coefficient of Definity ® at 37 °C was as much as 5 dB higher than the attenuation coefficient measured at 25 °C. However, the size distributions of Definity ® at 25 °C and 37 °C were similar. The estimated shell stiffness and viscosity decreased from 1.76 ± 0.18 N/m and 0.21 × 10 -6  ± 0.07 × 10 -6 kg/s at 25 °C to 1.01 ± 0.07 N/m and 0.04 × 10 -6  ± 0.04 × 10 -6 kg/s at 37 °C, respectively. Size-dependent differences in dissolution rates were observed within the UCA population at both 25 °C and 37 °C. Additionally, cooling the diluted UCA suspension from 37 °C to 25 °C accelerated the dissolution rate. These results indicate that although temperature affects the shell properties of Definity ® and can influence the stability of Definity ® , the size distribution of this agent is not affected by a temperature increase from 25 °C to 37 °C. Copyright © 2018 World Federation for Ultrasound in Medicine and Biology. Published by Elsevier Inc. All rights reserved.

  11. Meta-analyses of Theory use in Medication Adherence Intervention Research

    PubMed Central

    Conn, Vicki S.; Enriquez, Maithe; Ruppar, Todd M.; Chan, Keith C.

    2016-01-01

    Objective This systematic review applied meta-analytic procedures to integrate primary research that examined theory- or model-linked medication adherence interventions. Methods Extensive literature searching strategies were used to locate trials testing interventions with medication adherence behavior outcomes measured by electronic event monitoring, pharmacy refills, pill counts, and self-reports. Random-effects model analysis was used to calculate standardized mean difference effect sizes for medication adherence outcomes. Results Codable data were extracted from 146 comparisons with 19,348 participants. The most common theories and models were social cognitive theory and motivational interviewing. The overall weighted effect size for all interventions comparing treatment and control participants was 0.294. The effect size for interventions based on single-theories was 0.323 and for multiple-theory interventions was 0.214. Effect sizes for individual theories and models ranged from 0.041 to 0.447. The largest effect sizes were for interventions based on the health belief model (0.477) and adult learning theory (0.443). The smallest effect sizes were for interventions based on PRECEDE (0.041) and self-regulation (0.118). Conclusion These findings suggest that theory- and model-linked interventions have a significant but modest effect on medication adherence outcomes. PMID:26931748

  12. Interrelation of the effects caused by the rotation of the whispering gallery modes resonator

    NASA Astrophysics Data System (ADS)

    Dmitriyeva, Anna D.; Filatov, Yuri V.; Shalymov, Egor V.; Venediktov, Vladimir Yu.

    2016-11-01

    Optical whispering gallery modes resonators are characterized by unique properties: ultrahigh quality factor, small amount of the modes and small size. It allows to use them in compact high-precision measuring devices. In particular these resonators can be used in the composition of gyros. For today all researches, devoted to the application of the whispering gallery modes resonators in gyros, deals only with one of induced by the rotation effects (Sagnac effect or the influence of centrifugal forces on the resonator size). In this work we study the interrelation of the effects caused by the rotation of the whispering gallery modes resonator. Also in work we consider the possibility of joint application of both effects (the influence of centrifugal forces and Sagnac effect) for measuring angular velocity.

  13. Geographical variation in relationships between parental body size and offspring phenotype at birth

    PubMed Central

    Leary, Sam; Fall, Caroline; Osmond, Clive; Lovel, Hermione; Campbell, Doris; Eriksson, Johan; Forrester, Terrence; Godfrey, Keith; Hill, Jacqui; Jie, Mi; Law, Catherine; Newby, Rachel; Robinson, Sian; Yajnik, Chittaranjan

    2009-01-01

    Background Size and body proportions at birth are partly determined by maternal body composition, but most studies of mother-baby relationships have only considered the effects of maternal height and weight on offspring birthweight, and few have examined the size of effects. Paternal size and body composition also play a role, primarily through the fetal genome, although few studies have investigated relationships with neonatal phenotype. Methods Data from the UK, Finland, India, Sri Lanka, China, DR Congo, Nigeria and Jamaica were used to investigate the effects of maternal measures including estimates of muscle and fat (derived at 30-weeks gestation, N=16 418), and also paternal size (N=3 733) on neonatal phenotype, for singleton, liveborn, term births. Results After accounting for variation in maternal size and shape across populations, differences in neonatal phenotype were markedly reduced. Mother-baby relationships were similar across populations, although some were stronger in developing countries. Maternal height was generally the strongest predictor of neonatal length, maternal head circumference of neonatal head circumference, and maternal skinfold thickness of neonatal skinfolds. Relationships with maternal arm muscle area were generally weak. Data from fathers were limited to height and body mass index, but when compared with maternal height and body mass index, paternal effects were weaker in most studies. Conclusions Differences in maternal body composition account for a large part of the geographical variation in neonatal phenotype. The size of the effects of all maternal measures on neonatal phenotype suggests that nutrition at every stage of the mother's life cycle may influence fetal growth. Further research is needed into father-baby relationships and the genetic mechanisms which influence fetal growth. PMID:16929411

  14. Preliminary examination of the efficacy and safety of a standardized chamomile extract for chronic primary insomnia: a randomized placebo-controlled pilot study.

    PubMed

    Zick, Suzanna M; Wright, Benjamin D; Sen, Ananda; Arnedt, J Todd

    2011-09-22

    Despite being the most commonly used herbal for sleep disorders, chamomile's (Matricaria recutita) efficacy and safety for treating chronic primary insomnia is unknown. We examined the preliminary efficacy and safety of chamomile for improving subjective sleep and daytime symptoms in patients with chronic insomnia. We performed a randomized, double-blind, placebo-controlled pilot trial in 34 patients aged 18-65 years with DSM-IV primary insomnia for ≥ 6-months. Patients were randomized to 270 mg of chamomile twice daily or placebo for 28-days. The primary outcomes were sleep diary measures. Secondary outcomes included daytime symptoms, safety assessments, and effect size of these measures. There were no significant differences between groups in changes in sleep diary measures, including total sleep time (TST), sleep efficiency, sleep latency, wake after sleep onset (WASO), sleep quality, and number of awakenings. Chamomile did show modest advantage on daytime functioning, although these did not reach statistical significance. Effect sizes were generally small to moderate (Cohen's d ≤ 0.20 to < 0.60) with sleep latency, night time awakenings, and Fatigue Severity Scale (FSS), having moderate effect sizes in favor of chamomile. However, TST demonstrated a moderate effect size in favor of placebo. There were no differences in adverse events reported by the chamomile group compared to placebo. Chamomile could provide modest benefits of daytime functioning and mixed benefits on sleep diary measures relative to placebo in adults with chronic primary insomnia. However, further studies in select insomnia patients would be needed to investigate these conclusions.

  15. A meta-analysis of research on science teacher education practices associated with inquiry strategy

    NASA Astrophysics Data System (ADS)

    Sweitzer, Gary L.; Anderson, Ronald D.

    A meta-analysis was conducted of studies of teacher education having as measured outcomes one or more variables associated with inquiry teaching. Inquiry addresses those teacher behaviors that facilitate student acquisition of concepts and processes through strategies such as problem solving, uses of evidence, logical and analytical reasoning, clarification of values, and decision making. Studies which contained sufficient data for the calculation of an effect size were coded for 114 variables. These variables were divided into the following six major categories: study information and design characteristics, teacher and teacher trainee characteristics, student characteristics, treatment description, outcome description, and effect size calculation. A total of 68 studies resulting in 177 effect size calculations were coded. Mean effect sizes broken across selected variables were calculated.

  16. A new apparatus for real-time assessment of the particle size distribution of disintegrating tablets.

    PubMed

    Quodbach, Julian; Kleinebudde, Peter

    2014-11-01

    The aim of this study is the introduction of a novel apparatus that is capable of continuously measuring the particle size reduction of disintegrating tablets and analysis of the obtained results. The apparatus is constructed such that no particles pass directly through the pumping system. Thereby, the overall energy input into the particle suspension is reduced, and continuous measurement is possible without rapid destruction of the generated particles. The detected particle sizes at the beginning and at the end of the measurement differ greatly, depending on the applied disintegrant. The median particle sizes at the end of the measurement vary between 621.5 and 178.0 μm for different disintegrants. It is demonstrated that the particle size reduction follows an exponential function and that the fit parameters can be used to describe the disintegration behavior. A strong correlation between the median particle size of crospovidone disintegrants and generated particle size of the tablets is observed. This could be due to a more homogeneous distribution of the disintegrant particles in the tablets. Similar trends are observed for sodium starch glycolate and croscarmellose sodium. The new apparatus provides an innovative method to describe disintegrant effectiveness and efficiency. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.

  17. Impulsive Action, Psychological Stress, and Behavioral Sensitization to Nicotine in a Rat Model of lmpulsivity

    DTIC Science & Technology

    2010-06-30

    animals, increases in corticosterone (the rat equivalent of cortisol) or in sensitivity to corticosterone increases vulnerability to addictive effects ...Additionally, the corticosterone inhibitor suppressed the effects of cocaine to increase locomotor activity, which was measured once following cocaine...from the Kearns group indicated that the observed effect size (Cohen’s d) of the main effect of rat strain was 1.25. A cell size of 6 rats (totaling

  18. The role of early stages of cortical visual processing in size and distance judgment: a transcranial direct current stimulation study.

    PubMed

    Costa, Thiago L; Costa, Marcelo F; Magalhães, Adsson; Rêgo, Gabriel G; Nagy, Balázs V; Boggio, Paulo S; Ventura, Dora F

    2015-02-19

    Recent research suggests that V1 plays an active role in the judgment of size and distance. Nevertheless, no research has been performed using direct brain stimulation to address this issue. We used transcranial direct-current stimulation (tDCS) to directly modulate the early stages of cortical visual processing while measuring size and distance perception with a psychophysical scaling method of magnitude estimation in a repeated-measures design. The subjects randomly received anodal, cathodal, and sham tDCS in separate sessions starting with size or distance judgment tasks. Power functions were fit to the size judgment data, whereas logarithmic functions were fit to distance judgment data. Slopes and R(2) were compared with separate repeated-measures analyses of variance with two factors: task (size vs. distance) and tDCS (anodal vs. cathodal vs. sham). Anodal tDCS significantly decreased slopes, apparently interfering with size perception. No effects were found for distance perception. Consistent with previous studies, the results of the size task appeared to reflect a prothetic continuum, whereas the results of the distance task seemed to reflect a metathetic continuum. The differential effects of tDCS on these tasks may support the hypothesis that different physiological mechanisms underlie judgments on these two continua. The results further suggest the complex involvement of the early visual cortex in size judgment tasks that go beyond the simple representation of low-level stimulus properties. This supports predictive coding models and experimental findings that suggest that higher-order visual areas may inhibit incoming information from the early visual cortex through feedback connections when complex tasks are performed. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  19. Analysis of point source size on measurement accuracy of lateral point-spread function of confocal Raman microscopy

    NASA Astrophysics Data System (ADS)

    Fu, Shihang; Zhang, Li; Hu, Yao; Ding, Xiang

    2018-01-01

    Confocal Raman Microscopy (CRM) has matured to become one of the most powerful instruments in analytical science because of its molecular sensitivity and high spatial resolution. Compared with conventional Raman Microscopy, CRM can perform three dimensions mapping of tiny samples and has the advantage of high spatial resolution thanking to the unique pinhole. With the wide application of the instrument, there is a growing requirement for the evaluation of the imaging performance of the system. Point-spread function (PSF) is an important approach to the evaluation of imaging capability of an optical instrument. Among a variety of measurement methods of PSF, the point source method has been widely used because it is easy to operate and the measurement results are approximate to the true PSF. In the point source method, the point source size has a significant impact on the final measurement accuracy. In this paper, the influence of the point source sizes on the measurement accuracy of PSF is analyzed and verified experimentally. A theoretical model of the lateral PSF for CRM is established and the effect of point source size on full-width at half maximum of lateral PSF is simulated. For long-term preservation and measurement convenience, PSF measurement phantom using polydimethylsiloxane resin, doped with different sizes of polystyrene microspheres is designed. The PSF of CRM with different sizes of microspheres are measured and the results are compared with the simulation results. The results provide a guide for measuring the PSF of the CRM.

  20. Size, sounds and sex: interactions between body size and harmonic convergence signals determine mating success in Aedes aegypti.

    PubMed

    Cator, Lauren J; Zanti, Zacharo

    2016-12-01

    Several new mosquito control strategies will involve the release of laboratory reared males which will be required to compete with wild males for mates. Currently, the determinants of male mating success remain unclear. The presence of convergence between male and female harmonic flight tone frequencies during a mating attempt have been found to increase male mating success in the yellow fever mosquito, Aedes aegypti. Size has also been implicated as a factor in male mating success. Here, we investigated the relationships among body size, harmonic convergence signalling, and mating success. We predicted that harmonic convergence would be an important determinant of mating success and that large individuals would be more likely to converge. We used diet to manipulate male and female body size and then measured acoustic interactions during mating attempts between pairs of different body sizes. Additionally, we used playback experiments to measure the direct effect of size on signalling performance. In live pair interactions, harmonic convergence was found to be a significant predictor of copula formation. However, we also found interactions between harmonic convergence behaviour and body size. The probability that a given male successfully formed a copula was a consequence of his size, the size of the female encountered, and whether or not they converged. While convergence appears to be predictive of mating success regardless of size, the positive effect of convergence was modulated by size combinations. In playbacks, adult body size did not affect the probability of harmonic convergence responses. Both body size and harmonic convergence signalling were found to be determinants of male mating success. Our results suggest that in addition to measuring convergence ability of mass release lines that the size distribution of released males may need to be adjusted to complement the size distribution of females. We also found that diet amount alone cannot be used to increase male mating success or convergence probability. A clearer understanding of convergence behaviours, their relationship to mating success, and factors influencing convergence ability would provide the groundwork for improving the mating performance of laboratory reared lines.

  1. Sample size calculation in cost-effectiveness cluster randomized trials: optimal and maximin approaches.

    PubMed

    Manju, Md Abu; Candel, Math J J M; Berger, Martijn P F

    2014-07-10

    In this paper, the optimal sample sizes at the cluster and person levels for each of two treatment arms are obtained for cluster randomized trials where the cost-effectiveness of treatments on a continuous scale is studied. The optimal sample sizes maximize the efficiency or power for a given budget or minimize the budget for a given efficiency or power. Optimal sample sizes require information on the intra-cluster correlations (ICCs) for effects and costs, the correlations between costs and effects at individual and cluster levels, the ratio of the variance of effects translated into costs to the variance of the costs (the variance ratio), sampling and measuring costs, and the budget. When planning, a study information on the model parameters usually is not available. To overcome this local optimality problem, the current paper also presents maximin sample sizes. The maximin sample sizes turn out to be rather robust against misspecifying the correlation between costs and effects at the cluster and individual levels but may lose much efficiency when misspecifying the variance ratio. The robustness of the maximin sample sizes against misspecifying the ICCs depends on the variance ratio. The maximin sample sizes are robust under misspecification of the ICC for costs for realistic values of the variance ratio greater than one but not robust under misspecification of the ICC for effects. Finally, we show how to calculate optimal or maximin sample sizes that yield sufficient power for a test on the cost-effectiveness of an intervention.

  2. Role of geometric parameters in electrical measurements of insulating thin films deposited on a conductive substrate

    NASA Astrophysics Data System (ADS)

    Kumar, S.; Gerhardt, R. A.

    2012-03-01

    The effects of film thickness, electrode size and substrate thickness on the impedance parameters of alternating frequency dielectric measurements of insulating thin films deposited on conductive substrates were studied through parametric finite-element simulations. The quasi-static forms of Maxwell's electromagnetic equations in a time harmonic mode were solved using COMSOL Multiphysics® for several types of 2D models (linear and axisymmetric). The full 2D model deals with a configuration in which the impedance is measured between two surface electrodes on top of a film deposited on a conductive substrate. For the simplified 2D models, the conductive substrate is ignored and the two electrodes are placed on the top and bottom of the film. By comparing the full model and the simplified models, approximations and generalizations are deduced. For highly insulating films, such as the case of insulating SiO2 films on a conducting Si substrate, even the simplified models predict accurate capacitance values at all frequencies. However, the edge effects on the capacitance are found to be significant when the film thickness increases and/or the top electrode contact size decreases. The thickness of the substrate affects predominantly the resistive components of the dielectric response while having no significant effect on the capacitive components. Changing the electrode contact size or the film thickness determines the specific values of the measured resistance or capacitance while the material time constant remains the same, and thus this affects the frequency dependence that is able to be detected. This work highlights the importance of keeping in mind the film thickness and electrode contact size for the correct interpretation of the measured dielectric properties of micro/nanoscale structures that are often investigated using nanoscale capacitance measurements.

  3. Approach for measuring the chemistry of individual particles in the size range critical for cloud formation.

    PubMed

    Zauscher, Melanie D; Moore, Meagan J K; Lewis, Gregory S; Hering, Susanne V; Prather, Kimberly A

    2011-03-15

    Aerosol particles, especially those ranging from 50 to 200 nm, strongly impact climate by serving as nuclei upon which water condenses and cloud droplets form. However, the small number of analytical methods capable of measuring the composition of particles in this size range, particularly at the individual particle level, has limited our knowledge of cloud condensation nuclei (CCN) composition and hence our understanding of aerosols effect on climate. To obtain more insight into particles in this size range, we developed a method which couples a growth tube (GT) to an ultrafine aerosol time-of-flight mass spectrometer (UF-ATOFMS), a combination that allows in situ measurements of the composition of individual particles as small as 38 nm. The growth tube uses water to grow particles to larger sizes so they can be optically detected by the UF-ATOFMS, extending the size range to below 100 nm with no discernible changes in particle composition. To gain further insight into the temporal variability of aerosol chemistry and sources, the GT-UF-ATOFMS was used for online continuous measurements over a period of 3 days.

  4. Effect of ebastine on mosquito bites.

    PubMed

    Reunala, T; Brummer-Korvenkontio, H; Petman, L; Palosuo, T; Sarna, S

    1997-07-01

    Mosquito bites usually cause wealing and delayed bite papules. Cetirizine decreases wealing, bite papules and pruritus but the effect of other antihistamines on mosquito bites is unknown. We studied the effect of ebastine in 30 mosquito bite-sensitive adult subjects. Ebastine 10 mg or 20 mg and placebo were given for 4 days in a cross-over fashion. Aedes aegypti bites were given on forearms. The size of the bite lesions and pruritus (visual analogue score) were measured at 15 min, 2, 6, and 24 h after the bites. Twenty-five subjects were evaluable in the study. At 15 min ebastine decreased significantly the size of the bite lesion (p = 0.0017) and pruritus (p<0.0001). The effects of 10 mg and 20 mg of ebastine were similar. No significant effect was found at 2, 6 or 24 h, but when the measurements at all four time points were compiled the size of the bite lesion and pruritus score decreased significantly. Sedation occurred during ebastine treatment in 6 (21%) and during placebo treatment in 2 (7%) subjects. The present results show that prophylactically given ebastine is effective against immediate mosquito bite symptoms.

  5. Comparison of aerosol volume size distributions between column and surface measurements downwind of Seoul, Korea

    NASA Astrophysics Data System (ADS)

    Park, J. S.; Choi, Y.; Ghim, Y. S.

    2015-12-01

    The aerosol volume size distribution is one of the most important parameters in retrieving aerosol optical properties and studying radiative forcing. The column-integrated aerosol volume size distribution for AERONET was obtained from inversion product level 1.5 (22 bins between 0.1 and 30 μm in diameter) from the measurements of CIMEL sunphotometer (CE-318); that for SKYNET was obtained using skyrad.pack V5 (20 bins, 0.02-33 μm) from the measurements of PREDE skyradiometer (POM-02). The aerosol volume size distribution at the surface was measured using a wide range aerosol spectrometer system consisting of a scanning mobility particle scanner (Grimm, Model 5.419; 89 bins, 0.005-0.35 μm) and an optical particle counter (Grimm, Model 1.109; 31 bins, 0.27-34 μm). The measurement was conducted in Yongin, downwind of Seoul, Korea, from April 30 to June 27, 2015. The measurement site is located on the rooftop of a five-story building on the hill (37.34°N, 127.27°E, 167 m above sea level) in the global campus of Hankuk University of Foreign Studies. To investigate the discrepancy in effective diameter and fine mode volume fraction, we compared the volume size distributions when the measurement time coincided within 5 minutes because the measurement intervals were different between instruments.

  6. A Sorting Statistic with Application in Neurological Magnetic Resonance Imaging of Autism.

    PubMed

    Levman, Jacob; Takahashi, Emi; Forgeron, Cynthia; MacDonald, Patrick; Stewart, Natalie; Lim, Ashley; Martel, Anne

    2018-01-01

    Effect size refers to the assessment of the extent of differences between two groups of samples on a single measurement. Assessing effect size in medical research is typically accomplished with Cohen's d statistic. Cohen's d statistic assumes that average values are good estimators of the position of a distribution of numbers and also assumes Gaussian (or bell-shaped) underlying data distributions. In this paper, we present an alternative evaluative statistic that can quantify differences between two data distributions in a manner that is similar to traditional effect size calculations; however, the proposed approach avoids making assumptions regarding the shape of the underlying data distribution. The proposed sorting statistic is compared with Cohen's d statistic and is demonstrated to be capable of identifying feature measurements of potential interest for which Cohen's d statistic implies the measurement would be of little use. This proposed sorting statistic has been evaluated on a large clinical autism dataset from Boston Children's Hospital , Harvard Medical School , demonstrating that it can potentially play a constructive role in future healthcare technologies.

  7. A Sorting Statistic with Application in Neurological Magnetic Resonance Imaging of Autism

    PubMed Central

    Takahashi, Emi; Lim, Ashley; Martel, Anne

    2018-01-01

    Effect size refers to the assessment of the extent of differences between two groups of samples on a single measurement. Assessing effect size in medical research is typically accomplished with Cohen's d statistic. Cohen's d statistic assumes that average values are good estimators of the position of a distribution of numbers and also assumes Gaussian (or bell-shaped) underlying data distributions. In this paper, we present an alternative evaluative statistic that can quantify differences between two data distributions in a manner that is similar to traditional effect size calculations; however, the proposed approach avoids making assumptions regarding the shape of the underlying data distribution. The proposed sorting statistic is compared with Cohen's d statistic and is demonstrated to be capable of identifying feature measurements of potential interest for which Cohen's d statistic implies the measurement would be of little use. This proposed sorting statistic has been evaluated on a large clinical autism dataset from Boston Children's Hospital, Harvard Medical School, demonstrating that it can potentially play a constructive role in future healthcare technologies. PMID:29796236

  8. Using spatial uncertainty to manipulate the size of the attention focus.

    PubMed

    Huang, Dan; Xue, Linyan; Wang, Xin; Chen, Yao

    2016-09-01

    Preferentially processing behaviorally relevant information is vital for primate survival. In visuospatial attention studies, manipulating the spatial extent of attention focus is an important question. Although many studies have claimed to successfully adjust attention field size by either varying the uncertainty about the target location (spatial uncertainty) or adjusting the size of the cue orienting the attention focus, no systematic studies have assessed and compared the effectiveness of these methods. We used a multiple cue paradigm with 2.5° and 7.5° rings centered around a target position to measure the cue size effect, while the spatial uncertainty levels were manipulated by changing the number of cueing positions. We found that spatial uncertainty had a significant impact on reaction time during target detection, while the cue size effect was less robust. We also carefully varied the spatial scope of potential target locations within a small or large region and found that this amount of variation in spatial uncertainty can also significantly influence target detection speed. Our results indicate that adjusting spatial uncertainty is more effective than varying cue size when manipulating attention field size.

  9. Size Effects in the Resistivity of Kondo and Spin-Glass Wires

    NASA Astrophysics Data System (ADS)

    van Haesendonck, Chris

    1998-03-01

    Recently, several experiments have focused on possible size effects for the Kondo scattering in thin-film structures of very dilute magnetic alloys (concentration ~ 100 ppm) (For an overview, see M.A. Blachly and N. Giordano, Phys. Rev. B 51), 12537 (1995).. Intuitively, one expects size effects to occur as soon as the sample dimensions become smaller than the size of the Kondo screening cloud which induces a compensation of the local magnetic moments below the Kondo temperature. Since the size of the Kondo cloud is predicted to be of the order of 1 μ m, one should be able to observe pronounced size effects in thin-film Kondo alloys which have been patterned by standard electron beam lithography. Experiments performed by other groups have indeed revealed an important reduction of the slope of the Kondo resistivity for samples with micrometer dimensions. These experiments also show that the size effects are affected by disorder. On the other hand, our experiments on AuFe wires, which have been prepared by flash evaporation as well as by ion implantation, indicate the absence of size effects for the Kondo scattering down to a width of 38 nm. Therefore, the existence of the Kondo cloud remains a controversial issue. The size effects have also been investigated for more concentrated spin-glass alloys (concentration ~ 1 at.%). The resistivity measurements of thin-film spin glasses indicate that intrinsic size effects may be present for length scales below 100 nm (K.R. Lane et al., Phys. Rev. B 51), 945 (1995); G. Neuttiens et al., Europhys. Lett. 34, 617 (1996).. Due to the damping of the RKKY interaction by elastic defect scattering, size effects in the spin-glass regime can be strongly affected by disorder.

  10. The Mass-Size Relation of Quenched, Quiescent Galaxies in the WISP Survey

    NASA Astrophysics Data System (ADS)

    Pahl, Anthony; Scarlata, Claudia; Rutkowski, Michael J.; Zanella, Anita; Bagley, Micaela B.; Colbert, James W.; Baronchelli, Ivano; Henry, Alaina L.; Hathi, Nimish P.; Teplitz, Harry I.; Rafelski, Marc; Dai, Yu Sophia; Malkan, Matthew Arnold; Mehta, Vihang; Beck, Melanie

    2016-01-01

    The relation between the stellar mass and size, if measured for galaxies of similar types, can be a useful tool for studying galactic evolution. We study the mass-size relation of quenched, quiescent galaxies to determine the effect of star-formation history on the growth of these objects over time. The WFC3 Infrared Spectroscopic Parallels (WISP) survey is a large HST IR grism survey of over 385 fields of ~4 arcmin2 each, and it is ideal for studying the star-formation rate with its broad spectral coverage. Using a subset of these fields with deep IR data and measurements across both filters (28 fields), we perform a color selection and identify 83 quenched galaxies with a median z~1.6. With GALFIT, we measure their effective radius and sersic index on the 2-D surface brightness distribution in the F110W band. We perform fitting of grism spectra of the observed galaxies to derive redshift, stellar mass and age for all galaxies. We combine the size, stellar mass, and stellar age determinations to investigate whether the evolution of the mass-size relation over time is primarily driven by the entrance of newly quenched galaxies or by processes affecting the individual quenched galaxies.

  11. Measurements of submicron aerosols at the California-Mexico border during the Cal-Mex 2010 field campaign

    NASA Astrophysics Data System (ADS)

    Levy, Misti E.; Zhang, Renyi; Zheng, Jun; Tan, Haobo; Wang, Yuan; Molina, Luisa T.; Takahama, S.; Russell, L. M.; Li, Guohui

    2014-05-01

    We present measurements of submicron aerosols in Tijuana, Mexico during the Cal-Mex 2010 field campaign. A suite of aerosol instrumentations were deployed, including a hygroscopic-volatility tandem differential mobility analyzer (HV-TDMA), aerosol particle mass analyzer (APM), condensation particle counter (CPC), cavity ring-down spectrometer (CRDS), and nephelometer to measure the aerosol size distributions, effective density, hygroscopic growth factors (HGF), volatility growth factors (VGF), and optical properties. The average mass concentration of PM0.6 is 10.39 ± 7.61 μg m-3, and the derived average black carbon (BC) mass concentration is 2.87 ± 2.65 μg m-3. There is little new particle formation or particle growth during the day, and the mass loading is dominated by organic aerosols and BC, which on average are 37% and 27% of PM1.0, respectively. For four particle sizes of 46, 81, 151, and 240 nm, the measured particle effective density, HGFs, and VGFs exhibit distinct diurnal trends and size-dependence. For smaller particles (46 and 81 nm), the effective density distribution is unimodal during the day and night, signifying an internally mixed aerosol composition. In contrast, larger particles (151 and 240 nm) exhibit a bi-modal effective density distribution during the daytime, indicating an external mixture of fresh BC and organic aerosols, but a unimodal distribution during the night, corresponding to an internal mixture of BC and organic aerosols. The smaller particles show a noticeable diurnal trend in the effective density distribution, with the highest effective density (1.70 g cm-3) occurring shortly after midnight and the lowest value (0.90 g cm-3) occurring during the afternoon, corresponding most likely to primary organic aerosols and BC, respectively. Both HGFs and VGFs measured are strongly size-dependent. HGFs increase with increasing particle size, indicating that the largest particles are more hygroscopic. VGFs decrease with increasing particle size, indicating that larger particles are more volatile. The hygroscopicity distributions of smaller particles (46 and 81 nm) are unimodal, with a HGF value close to unity. Large particles typically exhibit a bi-modal distribution, with a non-hygroscopic mode and a hygroscopic mode. For all particle sizes, the VGF distributions are bimodal, with a primary non-volatile mode and a secondary volatile mode. The average extinction, scattering, and absorption coefficients are 86.04, 63.07, and 22.97 Mm-1, respectively, and the average SSA is 0.75. Our results reveal that gasoline and diesel vehicles produce a significant amount of black carbon particles in this US-Mexico border region, which impacts the regional environment and climate.

  12. Association between placentome size, measured using transrectal ultrasonography, and gestational age in cattle.

    PubMed

    Adeyinka, F D; Laven, R A; Lawrence, K E; van Den Bosch, M; Blankenvoorde, G; Parkinson, T J

    2014-03-01

    The aim of this study was to estimate whether fetal age could be accurately estimated using placentome size. Fifty-eight cows with confirmed conception dates in two herds were used for the study. The length of the long axis and cross-sectional area of placentomes close to the cervix were measured once every 10 days between approximately 60-130 days of gestation and once every 15 days between 130-160 days of gestation. Four to six placentomes were measured using transrectal ultrasonography in each uterine horn. A linear mixed model was used to establish the factors that were significantly associated with log mean placentome length and to create an equation to predict gestational age from mean placentome length. Limits of agreement analysis was then used to evaluate whether the predictions were sufficiently accurate for mean placentome length to be used, in practice, as a method of determining gestational age. Only age of gestation (p<0.001) and uterine horn (p=0.048) were found to have a significant effect on log mean placentome length. From the three models used to predict gestational age the one that used log mean placentome length of all placentomes, adjusting for the effect of horn, had the smallest 95% limits of agreement; ±33 days. That is, predicted gestational age had a 95% chance of being between 33 days greater and 33.7 days less than actual age. This is approximately twice that reported in studies using measurement of fetal size. Measurement of placentomes near to the cervix using transrectal ultrasonography was easily achieved. There was a significant association between placentome size and gestational age, but between-cow variation in placentome size and growth resulted in poor agreement between placentome size and gestational age. Although placentomes can be easily visualised during diagnosis of pregnancy using transrectal ultrasonography, mean placentome size should not be used to estimate gestational age.

  13. Studying the Effect of Light Quality on the Size of the Photosystem II Light Harvesting Complex

    ERIC Educational Resources Information Center

    Muhoz, Romualdo; Quiles, Maria J.

    2003-01-01

    In this article the effect of light quality on the size of the photosystem II (PSII) light harvesting complex (LHCII) is studied by measuring the chlorophyll fluorescence emitted by leaf sections of oat ("Avena sativa," var. Prevision) plants previously treated with either white light or with light filtered through blue, green, red or farred…

  14. Diagnosing hyperuniformity in two-dimensional, disordered, jammed packings of soft spheres.

    PubMed

    Dreyfus, Remi; Xu, Ye; Still, Tim; Hough, L A; Yodh, A G; Torquato, Salvatore

    2015-01-01

    Hyperuniformity characterizes a state of matter for which (scaled) density fluctuations diminish towards zero at the largest length scales. However, the task of determining whether or not an image of an experimental system is hyperuniform is experimentally challenging due to finite-resolution, noise, and sample-size effects that influence characterization measurements. Here we explore these issues, employing video optical microscopy to study hyperuniformity phenomena in disordered two-dimensional jammed packings of soft spheres. Using a combination of experiment and simulation we characterize the possible adverse effects of particle polydispersity, image noise, and finite-size effects on the assignment of hyperuniformity, and we develop a methodology that permits improved diagnosis of hyperuniformity from real-space measurements. The key to this improvement is a simple packing reconstruction algorithm that incorporates particle polydispersity to minimize the free volume. In addition, simulations show that hyperuniformity in finite-sized samples can be ascertained more accurately in direct space than in reciprocal space. Finally, our experimental colloidal packings of soft polymeric spheres are shown to be effectively hyperuniform.

  15. Diagnosing hyperuniformity in two-dimensional, disordered, jammed packings of soft spheres

    NASA Astrophysics Data System (ADS)

    Dreyfus, Remi; Xu, Ye; Still, Tim; Hough, L. A.; Yodh, A. G.; Torquato, Salvatore

    2015-01-01

    Hyperuniformity characterizes a state of matter for which (scaled) density fluctuations diminish towards zero at the largest length scales. However, the task of determining whether or not an image of an experimental system is hyperuniform is experimentally challenging due to finite-resolution, noise, and sample-size effects that influence characterization measurements. Here we explore these issues, employing video optical microscopy to study hyperuniformity phenomena in disordered two-dimensional jammed packings of soft spheres. Using a combination of experiment and simulation we characterize the possible adverse effects of particle polydispersity, image noise, and finite-size effects on the assignment of hyperuniformity, and we develop a methodology that permits improved diagnosis of hyperuniformity from real-space measurements. The key to this improvement is a simple packing reconstruction algorithm that incorporates particle polydispersity to minimize the free volume. In addition, simulations show that hyperuniformity in finite-sized samples can be ascertained more accurately in direct space than in reciprocal space. Finally, our experimental colloidal packings of soft polymeric spheres are shown to be effectively hyperuniform.

  16. Risky Sexual Behavior and Substance Use among Adolescents: A Meta-analysis

    PubMed Central

    Ritchwood, Tiarney D.; Ford, Haley; DeCoster, Jamie; Sutton, Marnie; Lochman, John E.

    2015-01-01

    This study presents the results of a meta-analysis of the association between substance use and risky sexual behavior among adolescents. 87 studies fit the inclusion criteria, containing a total of 104 independent effect sizes that incorporated more than 120,000 participants. The overall effect size for the relationship between substance use and risky sexual behavior was in the small to moderate range (r = .22, CI = .18, .26). Further analyses indicated that the effect sizes did not substantially vary across the type of substance use, but did substantially vary across the type of risky sexual behavior being assessed. Specifically, mean effect sizes were smallest for studies examining unprotected sex (r = .15, CI = .10, .20), followed by studies examining number of sexual partners (r = .25, CI = .21, .30), those examining composite measures of risky sexual behavior (r = .38, CI = .27, .48), and those examining sex with an intravenous drug user (r = .53, CI = .45, .60). Furthermore, our results revealed that the relationship between drug use and risky sexual behavior is moderated by several variables, including sex, ethnicity, sexuality, age, sample type, and level of measurement. Implications and future directions are discussed. PMID:25825550

  17. The effect of retinal pigment epithelial cell patch size on growth factor expression

    DOE PAGES

    Vargis, Elizabeth A.; Peterson, Cristen B.; Morrell-Falvey, Jennifer L.; ...

    2014-01-30

    The spatial organization of retinal pigment epithelial (RPE) cells grown in culture was controlled using micropatterning techniques in order to examine the effect of patch size on cell health and differentiation. Understanding this effect is a critical step in the development of multiplexed high throughput fluidic assays and provides a model for replicating disease states associated with the deterioration of retinal tissue during age-related macular degeneration (AMD). Microcontact printing of fibronectin on polystyrene and glass substrates was used to promote cell attachment, forming RPE patches of controlled size and shape. These colonies mimic the effect of atrophy and loss-of-function thatmore » occurs in the retina during degenerative diseases such as AMD. After 72 hours of cell growth, levels of vascular endothelial growth factor (VEGF), an important biomarker of AMD, were measured. Cells were counted and morphological indicators of cell viability and tight junction formation were assessed via fluorescence microscopy. As a result, up to a twofold increase of VEGF expression per cell was measured as colony size decreased, suggesting that the local microenvironment of, and connections between, RPE cells influences growth factor expression leading to the initiation and progression of diseases such as AMD.« less

  18. Cognitive-behavioral therapy for hypochondriasis/health anxiety: a meta-analysis of treatment outcome and moderators.

    PubMed

    Olatunji, Bunmi O; Kauffman, Brooke Y; Meltzer, Sari; Davis, Michelle L; Smits, Jasper A J; Powers, Mark B

    2014-07-01

    The present investigation employed meta-analysis to examine the efficacy of cognitive-behavioral therapy (CBT) for hypochondriasis/health anxiety as well as potential moderators that may be associated with outcome. A literature search revealed 15 comparisons among 13 randomized-controlled trials (RCTs) with a total sample size of 1081 participants that met inclusion criteria. Results indicated that CBT outperformed control conditions on primary outcome measures at post-treatment (Hedges's g = 0.95) and at follow-up (Hedges's g = 0.34). CBT also outperformed control conditions on measures of depression at post-treatment (Hedges's g = 0.64) and at follow-up (Hedges's g = 0.35). Moderator analyses revealed that higher pre-treatment severity of hypochondriasis/health anxiety was associated with greater effect sizes at follow-up visits and depression symptom severity was significantly associated with a lower in effect sizes at post-treatment. Although effect size did not vary as a function of blind assessment, smaller effect sizes were observed for CBT vs. treatment as usual control conditions than for CBT vs. waitlist control. A dose response relationship was also observed, such that a greater number of CBT sessions was associated with larger effect sizes at post-treatment. This review indicates that CBT is efficacious in the treatment of hypochondriasis/health anxiety and identifies potential moderators that are associated with outcome. The implications of these findings for further delineating prognostic and prescriptive indicators of CBT for hypochondriasis/health anxiety are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Application of radar chart array analysis to visualize effects of formulation variables on IgG1 particle formation as measured by multiple analytical techniques

    PubMed Central

    Kalonia, Cavan; Kumru, Ozan S.; Kim, Jae Hyun; Middaugh, C. Russell; Volkin, David B.

    2013-01-01

    This study presents a novel method to visualize protein aggregate and particle formation data to rapidly evaluate the effect of solution and stress conditions on the physical stability of an IgG1 monoclonal antibody (mAb). Radar chart arrays were designed so that hundreds of Microflow Digital Imaging (MFI) solution measurements, evaluating different mAb formulations under varying stresses, could be presented in a single figure with minimal loss of data resolution. These MFI radar charts show measured changes in subvisible particle number, size and morphology distribution as a change in the shape of polygons. Radar charts were also created to visualize mAb aggregate and particle formation across a wide size range by combining data sets from size exclusion chromatography (SEC), Archimedes resonant mass measurements, and MFI. We found that the environmental/mechanical stress condition (e.g., heat vs. agitation) was the most important factor in influencing the particle size and morphology distribution with this IgG1 mAb. Additionally, the presence of NaCl exhibited a pH and stress dependent behavior resulting in promotion or inhibition mAb particle formation. This data visualization technique provides a comprehensive analysis of the aggregation tendencies of this IgG1 mAb in different formulations with varying stresses as measured by different analytical techniques. PMID:24122556

  20. Evidence of scattering effects on the sizes of interplanetary Type III radio bursts

    NASA Technical Reports Server (NTRS)

    Steinberg, J. L.; Hoang, S.; Dulk, G. A.

    1985-01-01

    An analysis is conducted of 162 interplanetary Type III radio bursts; some of these bursts have been observed in association with fast electrons and Langmuir wave events at 1 AU and, in addition, have been subjected to in situ plasma parameter measurements. It is noted that the sizes of burst sources are anomalously large, compared to what one would anticipate on the basis of the interplanetary plasma density distribution, and that the variation of source size with frequency, when compared with the plasma frequency variation measured in situ, implies that the source sizes expand with decreasing frequency to fill a cone whose apex is at the sun. It is also found that some local phenomenon near the earth controls the apparent size of low frequency Type III sources.

  1. Systematic review finds major deficiencies in sample size methodology and reporting for stepped-wedge cluster randomised trials

    PubMed Central

    Martin, James; Taljaard, Monica; Girling, Alan; Hemming, Karla

    2016-01-01

    Background Stepped-wedge cluster randomised trials (SW-CRT) are increasingly being used in health policy and services research, but unless they are conducted and reported to the highest methodological standards, they are unlikely to be useful to decision-makers. Sample size calculations for these designs require allowance for clustering, time effects and repeated measures. Methods We carried out a methodological review of SW-CRTs up to October 2014. We assessed adherence to reporting each of the 9 sample size calculation items recommended in the 2012 extension of the CONSORT statement to cluster trials. Results We identified 32 completed trials and 28 independent protocols published between 1987 and 2014. Of these, 45 (75%) reported a sample size calculation, with a median of 5.0 (IQR 2.5–6.0) of the 9 CONSORT items reported. Of those that reported a sample size calculation, the majority, 33 (73%), allowed for clustering, but just 15 (33%) allowed for time effects. There was a small increase in the proportions reporting a sample size calculation (from 64% before to 84% after publication of the CONSORT extension, p=0.07). The type of design (cohort or cross-sectional) was not reported clearly in the majority of studies, but cohort designs seemed to be most prevalent. Sample size calculations in cohort designs were particularly poor with only 3 out of 24 (13%) of these studies allowing for repeated measures. Discussion The quality of reporting of sample size items in stepped-wedge trials is suboptimal. There is an urgent need for dissemination of the appropriate guidelines for reporting and methodological development to match the proliferation of the use of this design in practice. Time effects and repeated measures should be considered in all SW-CRT power calculations, and there should be clarity in reporting trials as cohort or cross-sectional designs. PMID:26846897

  2. Open-Filter Optical SSA Analysis Considerations

    NASA Astrophysics Data System (ADS)

    Lambert, J.

    2016-09-01

    Optical Space Situational Awareness (SSA) sensors used for space object detection and orbit refinement measurements are typically operated in an "open-filter" mode without any spectral filters to maximize sensitivity and signal-to-noise. These same optical brightness measurements are often also employed for size determination (e.g., for orbital debris), object correlation, and object status change. These functions, especially when performed using multiple sensors, are highly dependent on sensor calibration for measurement accuracy. Open-filter SSA sensors are traditionally calibrated against the cataloged visual magnitudes of solar-type stars which have similar spectral distributions as the illuminating source, the Sun. The stellar calibration is performed to a high level of accuracy, a few hundredths of a magnitude, by observing many stars over a range of elevation angles to determine sensor, telescope, and atmospheric effects. However, space objects have individual color properties which alter the reflected solar illumination producing spectral distributions which differ from those of the calibration stars. When the stellar calibrations are applied to the space object measurements, visual magnitude values are obtained which are systematically biased. These magnitudes combined with the unknown Bond albedos of the space objects result in systematically biased size determinations which will differ between sensors. Measurements of satellites of known sizes and surface materials have been analyzed to characterize these effects. The results have combined into standardized Bond albedos to correct the measured magnitudes into object sizes. However, the actual albedo values will vary between objects and represent a mean correction subject to some uncertainty. The objective of this discussion is to characterize the sensor spectral biases that are present in open-filter optical observations and examine the resulting brightness and albedo uncertainties that should accompany object size, correlation, or status change determinations, especially in the SSA analyses of individual space objects using data from multiple sensors.

  3. Determination of the cumulus size distribution from LANDSAT pictures

    NASA Technical Reports Server (NTRS)

    Karg, E.; Mueller, H.; Quenzel, H.

    1983-01-01

    Varying insolation causes undesirable thermic stress to the receiver of a solar power plant. The rapid change of insolation depends on the size distribution of the clouds; in order to measure these changes, it is suitable to determine typical cumulus size distributions. For this purpose, LANDSAT-images are adequate. Several examples of cumulus size distributions will be presented and their effects on the operation of a solar power plant are discussed.

  4. An Exploratory Analysis of Projection-Standard Variables (Screen Size, Image Size and Image Contrast) in Terms of Their Effects on the Speed and Accuracy of Discrimination. Final Report.

    ERIC Educational Resources Information Center

    Metcalf, Richard M.

    Although there has been previous research concerned with image size, brightness, and contrast in projection standards, the work has lacked careful conceptualization. In this study, size was measured in terms of the visual angle subtended by the material, brightness was stated in foot-lamberts, and contrast was defined as the ratio of the…

  5. Study on effective MOSFET channel length extracted from gate capacitance

    NASA Astrophysics Data System (ADS)

    Tsuji, Katsuhiro; Terada, Kazuo; Fujisaka, Hisato

    2018-01-01

    The effective channel length (L GCM) of metal-oxide-semiconductor field-effect transistors (MOSFETs) is extracted from the gate capacitances of actual-size MOSFETs, which are measured by charge-injection-induced-error-free charge-based capacitance measurement (CIEF CBCM). To accurately evaluate the capacitances between the gate and the channel of test MOSFETs, the parasitic capacitances are removed by using test MOSFETs having various channel sizes and a source/drain reference device. A strong linear relationship between the gate-channel capacitance and the design channel length is obtained, from which L GCM is extracted. It is found that L GCM is slightly less than the effective channel length (L CRM) extracted from the measured MOSFET drain current. The reason for this is discussed, and it is found that the capacitance between the gate electrode and the source and drain regions affects this extraction.

  6. Sleep-deprivation effect on human performance: a meta-analysis approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Candice D. Griffith; Candice D. Griffith; Sankaran Mahadevan

    Human fatigue is hard to define since there is no direct measure of fatigue, much like stress. Instead fatigue must be inferred from measures that are affected by fatigue. One such measurable output affected by fatigue is reaction time. In this study the relationship of reaction time to sleep deprivation is studied. These variables were selected because reaction time and hours of sleep deprivation are straightforward characteristics of fatigue to begin the investigation of fatigue effects on performance. Meta-analysis, a widely used procedure in medical and psychological studies, is applied to the variety of fatigue literature collected from various fieldsmore » in this study. Meta-analysis establishes a procedure for coding and analyzing information from various studies to compute an effect size. In this research the effect size reported is the difference between standardized means, and is found to be -0.6341, implying a strong relationship between sleep deprivation and performance degradation.« less

  7. Holistic Processing in the Composite Task Depends on Face Size.

    PubMed

    Ross, David A; Gauthier, Isabel

    Holistic processing is a hallmark of face processing. There is evidence that holistic processing is strongest for faces at identification distance, 2 - 10 meters from the observer. However, this evidence is based on tasks that have been little used in the literature and that are indirect measures of holistic processing. We use the composite task- a well validated and frequently used paradigm - to measure the effect of viewing distance on holistic processing. In line with previous work, we find a congruency x alignment effect that is strongest for faces that are close (2m equivalent distance) than for faces that are further away (24m equivalent distance). In contrast, the alignment effect for same trials, used by several authors to measure holistic processing, produced results that are difficult to interpret. We conclude that our results converge with previous findings providing more direct evidence for an effect of size on holistic processing.

  8. Holistic Processing in the Composite Task Depends on Face Size

    PubMed Central

    Ross, David A.; Gauthier, Isabel

    2015-01-01

    Holistic processing is a hallmark of face processing. There is evidence that holistic processing is strongest for faces at identification distance, 2 – 10 meters from the observer. However, this evidence is based on tasks that have been little used in the literature and that are indirect measures of holistic processing. We use the composite task– a well validated and frequently used paradigm – to measure the effect of viewing distance on holistic processing. In line with previous work, we find a congruency x alignment effect that is strongest for faces that are close (2m equivalent distance) than for faces that are further away (24m equivalent distance). In contrast, the alignment effect for same trials, used by several authors to measure holistic processing, produced results that are difficult to interpret. We conclude that our results converge with previous findings providing more direct evidence for an effect of size on holistic processing. PMID:26500423

  9. [Characteristics and its forming mechanism on grain size distribution of suspended matter at Changjiang Estuary].

    PubMed

    Pang, Chong-guang; Yu, Wei; Yang, Yang

    2010-03-01

    In July of 2008, under the natural condition of sea water, the Laser in-situ scattering and transmissometry (LISST-100X Type C) was used to measure grain size distribution spectrum and volume concentration of total suspended matter in the sea water, including flocs at different layers of 24 sampling stations at Changjiang Estuary and its adjacent sea. The characteristics and its forming mechanism on grain size distribution of total suspended matter were analyzed based on the observation data of LISST-100X Type C, and combining with the temperature, salinity and turbidity of sea water, simultaneously observed by Alec AAQ1183. The observation data showed that the average median grain size of total suspended matter was about 4.69 phi in the whole measured sea area, and the characteristics of grain size distribution was relatively poor sorted, wide kurtosis, and basically symmetrical. The conclusion could be drawn that vertically average volume concentration decreased with the distance from the coastline, while median grain size had an increase trend with the distance, for example, at 31.0 degrees N section, the depth-average median grain size had been increased from 11 microm up to 60 microm. With the increasing of distance from the coast, the concentration of fine suspended sediment reduced distinctly, nevertheless some relatively big organic matter or big flocs appeared in quantity, so its grain size would rise. The observation data indicated that the effective density was ranged from 246 kg/m3 to 1334 kg/m, with average was 613 kg/m3. When the concentration of total suspended matter was relatively high, median grain size of total suspended matter increased with the water depth, while effective density decreased with the depth, because of the faster settling velocity and less effective density of large flocs that of small flocs. As for station 37 and 44, their correlation coefficients between effective density and median grain size were larger than 0.9.

  10. New phase method of measuring particle size with laser Doppler radar

    NASA Astrophysics Data System (ADS)

    Zemlianskii, Vladimir M.

    1996-06-01

    A vast field of non-contact metrology, vibrometry, dynamics and microdynamics problems solved on the basis of laser Doppler method resulted in the development of great variety of laser Doppler radar (LDR). In coherent LDR few beams with various polarization are generally adopted, that are directed at the zone of measurement, through which the probing air stream moves. Studies of various coherent LDR demonstrated that polarization-phase effects of scattering can in some cases considerably effect on the signal-to-noise ratio of the Doppler signal. On the other side using phase effects can simultaneous measurement of size and velocity of spherical particles. New possibilities for improving the accuracy of measuring spherical particles' sizes come to light when application is made in coherent LDR of two waves- probing and one out of the types of symmetrical reception of scattered radiation, during which phase-conjugate signals are formed. The theoretical analysis on the basis of the scattering theory showed, that in symmetrical reception of scattered radiation with respect to the planes OXZ and OYZ output signal of the photoreceiver contains two high- frequency signal components, which in relation to parameters of the probing and size, can either be in phase or antiphase. Results of numerical modeling are presented: amplitude of high frequency signal, coefficient of phase and polarization matching of mixed waves, the depths of photocurrent modulation and also signal's phase in relation to the angle between the probing beams. Phase method of determining particle's sizes based on the use of two wavelengths probing and symmetrical reception of scattered radiation in which conditions for the formation of phase conjugated high-frequency signals are satisfied is presented.

  11. The effects of age, viewing distance, display type, font type, colour contrast and number of syllables on the legibility of Korean characters.

    PubMed

    Kong, Yong-Ku; Lee, Inseok; Jung, Myung-Chul; Song, Young-Woong

    2011-05-01

    This study evaluated the effects of age (20s and 60s), viewing distance (50 cm, 200 cm), display type (paper, monitor), font type (Gothic, Ming), colour contrast (black letters on white background, white letters on black background) and number of syllables (one, two) on the legibility of Korean characters by using the four legibility measures (minimum letter size for 100% correctness, maximum letter size for 0% correctness, minimum letter size for the least discomfort and maximum letter size for the most discomfort). Ten subjects in each age group read the four letters presented on a slide (letter size varied from 80 pt to 2 pt). Subjects also subjectively rated the reading discomfort of the letters on a 4-point scale (1 = no discomfort, 4 = most discomfort). According to the ANOVA procedure, age, viewing distance and font type significantly affected the four dependent variables (p < 0.05), while the main effect of colour contrast was not statistically significant for any measures. Two-syllable letters had smaller letters than one-syllable letters in the two correctness measures. The younger group could see letter sizes two times smaller than the old group could and the viewing distance of 50 cm showed letters about three times smaller than those at a 200 cm viewing distance. The Gothic fonts were smaller than the Ming fonts. Monitors were smaller than paper for correctness and maximum letter size for the most discomfort. From a comparison of the results for correctness and discomfort, people generally preferred larger letter sizes to those that they could read. The findings of this study may provide basic information for setting a global standard of letter size or font type to improve the legibility of characters written in Korean. STATEMENT OF RELEVANCE: Results obtained in this study will provide basic information and guidelines for setting standards of letter size and font type to improve the legibility of characters written in Korean. Also, the results might offer useful information for people who are working on design of visual displays.

  12. The effects of sex, ethnicity, and sexual orientation on self-measured digit ratio (2D:4D).

    PubMed

    Manning, John T; Churchill, Andrew J G; Peters, Michael

    2007-04-01

    We used self-reported direct finger measurements from 255,116 participants in a BBC Internet survey to investigate the measurement of 2D:4D ratios and their association with sex, ethnicity, and sexual orientation. We found significant sex differences such that males had lower 2D:4D than females and the effect size of the sex differences was greatest for right hand 2D:4D. Mean 2D:4D was lower for right hands than for left hands in men, but lower for left hands compared to right hands in women. The sexual dimorphism in 2D:4D was present across ethnic and country groupings, suggesting that it is universal in humans. However, there was also evidence that mean 2D:4D varied across ethnic groups with higher ratios for Whites, Non-Chinese Asians, and Mid-Easterners and lower ratios in Chinese and Black samples. There were significant differences in 2D:4D across sexual orientation groups but these were confined to men. Male homosexuals and bisexuals had higher mean 2D:4D (suggesting exposure to lower prenatal T) than heterosexuals. The effect was present in Whites, but there was no evidence for the pattern among Black and Chinese participants. In women, there were no significant effects of sexual orientation on 2D:4D. Most studies of sexual orientation effects on 2D:4D have measured finger length from photocopies of the hands. In comparison, our self-reported measures gave higher mean 2D:4D, lower effect sizes, and, in some instances, different patterns of effect size. The implications of our findings for future research into 2D:4D are discussed.

  13. Coupled crystal orientation-size effects on the strength of nano crystals

    PubMed Central

    Yuan, Rui; Beyerlein, Irene J.; Zhou, Caizhi

    2016-01-01

    We study the combined effects of grain size and texture on the strength of nanocrystalline copper (Cu) and nickel (Ni) using a crystal-plasticity based mechanics model. Within the model, slip occurs in discrete slip events exclusively by individual dislocations emitted statistically from the grain boundaries. We show that a Hall-Petch relationship emerges in both initially texture and non-textured materials and our values are in agreement with experimental measurements from numerous studies. We find that the Hall-Petch slope increases with texture strength, indicating that preferred orientations intensify the enhancements in strength that accompany grain size reductions. These findings reveal that texture is too influential to be neglected when analyzing and engineering grain size effects for increasing nanomaterial strength. PMID:27185364

  14. Effects of grain size on the corrosion resistance of pure magnesium by cooling rate-controlled solidification

    NASA Astrophysics Data System (ADS)

    Liu, Yichi; Liu, Debao; You, Chen; Chen, Minfang

    2015-09-01

    The aim of this study was to investigate the effect of grain size on the corrosion resistance of pure magnesium developed for biomedical applications. High-purity magnesium samples with different grain size were prepared by the cooling rate-controlled solidification. Electrochemical and immersion tests were employed to measure the corrosion resistance of pure magnesium with different grain size. The electrochemical polarization curves indicated that the corrosion susceptibility increased as the grain size decrease. However, the electrochemical impedance spectroscopy (EIS) and immersion tests indicated that the corrosion resistance of pure magnesium is improved as the grain size decreases. The improvement in the corrosion resistance is attributed to refine grain can produce more uniform and density film on the surface of sample.

  15. Frequency Selection for Multi-frequency Acoustic Measurement of Suspended Sediment

    NASA Astrophysics Data System (ADS)

    Chen, X.; HO, H.; Fu, X.

    2017-12-01

    Multi-frequency acoustic measurement of suspended sediment has found successful applications in marine and fluvial environments. Difficult challenges remain in regard to improving its effectiveness and efficiency when applied to high concentrations and wide size distributions in rivers. We performed a multi-frequency acoustic scattering experiment in a cylindrical tank with a suspension of natural sands. The sands range from 50 to 600 μm in diameter with a lognormal size distribution. The bulk concentration of suspended sediment varied from 1.0 to 12.0 g/L. We found that the commonly used linear relationship between the intensity of acoustic backscatter and suspended sediment concentration holds only at sufficiently low concentrations, for instance below 3.0 g/L. It fails at a critical value of concentration that depends on measurement frequency and the distance between the transducer and the target point. Instead, an exponential relationship was found to work satisfactorily throughout the entire range of concentration. The coefficient and exponent of the exponential function changed, however, with the measuring frequency and distance. Considering the increased complexity of inverting the concentration values when an exponential relationship prevails, we further analyzed the relationship between measurement error and measuring frequency. It was also found that the inversion error may be effectively controlled within 5% if the frequency is properly set. Compared with concentration, grain size was found to heavily affect the selection of optimum frequency. A regression relationship for optimum frequency versus grain size was developed based on the experimental results.

  16. Infrared reflectance spectra: Effects of particle size, provenance and preparation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Su, Yin-Fong; Myers, Tanya L.; Brauer, Carolyn S.

    2014-09-22

    We have recently developed methods for making more accurate infrared total and diffuse directional - hemispherical reflectance measurements using an integrating sphere. We have found that reflectance spectra of solids, especially powders, are influenced by a number of factors including the sample preparation method, the particle size and morphology, as well as the sample origin. On a quantitative basis we have investigated some of these parameters and the effects they have on reflectance spectra, particularly in the longwave infrared. In the IR the spectral features may be observed as either maxima or minima: In general, upward-going peaks in the reflectancemore » spectrum result from strong surface scattering, i.e. rays that are reflected from the surface without bulk penetration, whereas downward-going peaks are due to either absorption or volume scattering, i.e. rays that have penetrated or refracted into the sample interior and are not reflected. The light signals reflected from solids usually encompass all such effects, but with strong dependencies on particle size and preparation. This paper measures the reflectance spectra in the 1.3 – 16 micron range for various bulk materials that have a combination of strong and weak absorption bands in order to observe the effects on the spectral features: Bulk materials were ground with a mortar and pestle and sieved to separate the samples into various size fractions between 5 and 500 microns. The median particle size is demonstrated to have large effects on the reflectance spectra. For certain minerals we also observe significant spectral change depending on the geologic origin of the sample. All three such effects (particle size, preparation and provenance) result in substantial change in the reflectance spectra for solid materials; successful identification algorithms will require sufficient flexibility to account for these parameters.« less

  17. Infrared reflectance spectra: effects of particle size, provenance and preparation

    NASA Astrophysics Data System (ADS)

    Su, Yin-Fong; Myers, Tanya L.; Brauer, Carolyn S.; Blake, Thomas A.; Forland, Brenda M.; Szecsody, J. E.; Johnson, Timothy J.

    2014-10-01

    We have recently developed methods for making more accurate infrared total and diffuse directional - hemispherical reflectance measurements using an integrating sphere. We have found that reflectance spectra of solids, especially powders, are influenced by a number of factors including the sample preparation method, the particle size and morphology, as well as the sample origin. On a quantitative basis we have investigated some of these parameters and the effects they have on reflectance spectra, particularly in the longwave infrared. In the IR the spectral features may be observed as either maxima or minima: In general, upward-going peaks in the reflectance spectrum result from strong surface scattering, i.e. rays that are reflected from the surface without bulk penetration, whereas downward-going peaks are due to either absorption or volume scattering, i.e. rays that have penetrated or refracted into the sample interior and are not reflected. The light signals reflected from solids usually encompass all such effects, but with strong dependencies on particle size and preparation. This paper measures the reflectance spectra in the 1.3 - 16 micron range for various bulk materials that have a combination of strong and weak absorption bands in order to observe the effects on the spectral features: Bulk materials were ground with a mortar and pestle and sieved to separate the samples into various size fractions between 5 and 500 microns. The median particle size is demonstrated to have large effects on the reflectance spectra. For certain minerals we also observe significant spectral change depending on the geologic origin of the sample. All three such effects (particle size, preparation and provenance) result in substantial change in the reflectance spectra for solid materials; successful identification algorithms will require sufficient flexibility to account for these parameters.

  18. Measuring the costs and benefits of conservation programs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Einhorn, M.A.

    1985-07-25

    A step-by-step analysis of the effects of utility-sponsored conservation promoting programs begins by identifying several factors which will reduce a program's effectiveness. The framework for measuring cost savings and designing a conservation program needs to consider the size of appliance subsidies, what form incentives should take, and how will customer behavior change as a result of incentives. Continual reevaluation is necessary to determine whether to change the size of rebates or whether to continue the program. Analytical tools for making these determinations are improving as conceptual breakthroughs in econometrics permit more rigorous analysis. 5 figures.

  19. Effects of parent loss: interaction with family size and sibling order.

    PubMed

    Sklar, A D; Harris, R F

    1985-06-01

    The authors studied the effect of parent loss during the first 18 years of life and its interactions with family size and sibling order in a nonpsychiatric population of 247 men. Groups defined by loss type, family size, and sibling order were compared using MMPI scale scores. The results strongly suggest that parent loss and family size and their interaction have an important impact on adult personality traits as measured by MMPI scores. The strong adverse impact of intermittent loss and temporary loss in large families (much greater than that of permanent loss) is a crucial finding not previously noted in the literature.

  20. Investigation of the stability of Platinum nanoparticles incorporated in mesoporous silica with different pore sizes.

    PubMed

    Yano, Kazuhisa; Zhang, Shuyi; Pan, Xiaoqing; Tatsuda, Narihito

    2014-05-01

    The effect of the pore size of mesoporous silica on the stability of Pt nanoparticles (NPs) has been investigated. TEM observation and XRD measurement were conducted in situ for Pt loaded mesoporous silica with different mesopore sizes. It turns out that smaller pores are more effective to stabilize Pt NPs below 600 °C. However, aggregation of Pt NPs on the surface of particles is not fully suppressed more than 1000 °C in ambient atmosphere even though smaller mesopore size is applied. The type of precursor does not affect the stability of Pt NPs. Copyright © 2014. Published by Elsevier Inc.

  1. Reproductive success in a natural population of male three-spined stickleback Gasterosteus aculeatus: effects of nuptial colour, parasites and body size.

    PubMed

    Sparkes, T C; Rush, V; Kopp, D A; Foster, S A

    2013-05-01

    The effects of nuptial colour, parasites and body size on reproductive success were examined in a natural population of three-spined stickleback Gasterosteus aculeatus. Reproductive males were collected, with the contents of their nests, during the embryo-guarding stage from Lynne Lake (Cook Inlet, Alaska, U.S.A.), and nuptial colour, infection status and body size were recorded. Regression analysis revealed that male body size was the only predictor, of those measured, of reproductive success in nature. © 2013 The Authors. Journal of Fish Biology © 2013 The Fisheries Society of the British Isles.

  2. Signal detection theory applied to three visual search tasks--identification, yes/no detection and localization.

    PubMed

    Cameron, E Leslie; Tai, Joanna C; Eckstein, Miguel P; Carrasco, Marisa

    2004-01-01

    Adding distracters to a display impairs performance on visual tasks (i.e. the set-size effect). While keeping the display characteristics constant, we investigated this effect in three tasks: 2 target identification, yes-no detection with 2 targets, and 8-alternative localization. A Signal Detection Theory (SDT) model, tailored for each task, accounts for the set-size effects observed in identification and localization tasks, and slightly under-predicts the set-size effect in a detection task. Given that sensitivity varies as a function of spatial frequency (SF), we measured performance in each of these three tasks in neutral and peripheral precue conditions for each of six spatial frequencies (0.5-12 cpd). For all spatial frequencies tested, performance on the three tasks decreased as set size increased in the neutral precue condition, and the peripheral precue reduced the effect. Larger set-size effects were observed at low SFs in the identification and localization tasks. This effect can be described using the SDT model, but was not predicted by it. For each of these tasks we also established the extent to which covert attention modulates performance across a range of set sizes. A peripheral precue substantially diminished the set-size effect and improved performance, even at set size 1. These results provide support for distracter exclusion, and suggest that signal enhancement may also be a mechanism by which covert attention can impose its effect.

  3. Effect of various digital processing algorithms on the measurement accuracy of endodontic file length.

    PubMed

    Kal, Betül Ilhan; Baksi, B Güniz; Dündar, Nesrin; Sen, Bilge Hakan

    2007-02-01

    The aim of this study was to compare the accuracy of endodontic file lengths after application of various image enhancement modalities. Endodontic files of three different ISO sizes were inserted in 20 single-rooted extracted permanent mandibular premolar teeth and standardized images were obtained. Original digital images were then enhanced using five processing algorithms. Six evaluators measured the length of each file on each image. The measurements from each processing algorithm and each file size were compared using repeated measures ANOVA and Bonferroni tests (P = 0.05). Paired t test was performed to compare the measurements with the true lengths of the files (P = 0.05). All of the processing algorithms provided significantly shorter measurements than the true length of each file size (P < 0.05). The threshold enhancement modality produced significantly higher mean error values (P < 0.05), while there was no significant difference among the other enhancement modalities (P > 0.05). Decrease in mean error value was observed with increasing file size (P < 0.05). Invert, contrast/brightness and edge enhancement algorithms may be recommended for accurate file length measurements when utilizing storage phosphor plates.

  4. Modeling the Effect of Grain Size Mixing on Thermal Inertia Values Derived from Diurnal and Seasonal THEMIS Measurements

    NASA Astrophysics Data System (ADS)

    McCarty, C.; Moersch, J.

    2017-12-01

    Sedimentary processes have slowed over Mars' geologic history. Analysis of the surface today can provide insight into the processes that may have affected it over its history. Sub-resolved checkerboard mixtures of materials with different thermal inertias (and therefore different grain sizes) can lead to differences in thermal inertia values inferred from night and day radiance observations. Information about the grain size distribution of a surface can help determine the degree of sorting it has experienced or it's geologic maturity. Standard methods for deriving thermal inertia from measurements made with THEMIS can give values for the same location that vary by as much as 20% between scenes. Such methods make the assumption that each THEMIS pixel contains material that has uniform thermophysical properties. Here we propose that if a mixture of small and large particles is present within a pixel, the inferred thermal inertia will be strongly dominated by whichever particle is warmer at the time of the measurement because the power radiated by a surface is proportional (by the Stefan-Boltzmann law) to the fourth power of its temperature. This effect will result in a change in thermal inertia values inferred from measurements taken at different times of day and night. Therefore, we expect to see correlation between the magnitude of diurnal variations in inferred thermal inertia values and the degree of grain size mixing for a given pixel location. Preliminary work has shown that the magnitude of such diurnal variation in inferred thermal inertias is sufficient to detect geologically useful differences in grain size distributions. We hypothesize that at least some of the 20% variability in thermal inertias inferred from multiple scenes for a given location could be attributed to sub-pixel grain size mixing rather than uncertainty inherent to the experiment, as previously thought. Mapping the difference in inferred thermal inertias from day and night THEMIS observations may prove to be a new way of distinguishing surfaces that have relatively uniform grain sizes from those that have mixed grain sizes. Assessing the effects of different geologic processes can be aided by noting variations in grain size distributions, so this method may be useful as a new way to extract geologic interpretations from the THEMIS thermal data set.

  5. Steep Delay Discounting and Addictive Behavior: A Meta-Analysis of Continuous Associations

    PubMed Central

    Amlung, Michael; Vedelago, Lana; Acker, John; Balodis, Iris; MacKillop, James

    2016-01-01

    Aims To synthesize continuous associations between delayed reward discounting (DRD) and both addiction severity and quantity-frequency (QF); to examine moderators of these relationships; and to investigate publication bias. Methods Meta-analysis of published studies examining continuous associations between DRD and addictive behaviors. Published, peer-reviewed studies on addictive behaviors (alcohol, tobacco, cannabis, stimulants, opiates, and gambling) were identified via PubMed, MEDLINE, and PsycInfo. Studies were restricted to DRD measures of monetary gains. Random effects meta-analysis was conducted using Pearson’s r as the effect size. Publication bias was evaluated using fail-safe N, Begg-Mazumdar and Egger’s tests, meta-regression of publication year and effect size, and imputation of missing studies. Results The primary meta-analysis revealed a small magnitude effect size that was highly significant (r = 0.14, p < 10−14). Significantly larger effect sizes were observed for studies examining severity compared with QF (p = 0.01), but not between the type of addictive behavior (p = 0.30) or DRD assessment (p = 0.90). Indices of publication bias suggested a modest impact of unpublished findings. Conclusions Delayed reward discounting is robustly associated with continuous measures of addiction severity and quantity-frequency. This relation is generally robust across type of addictive behavior and delayed reward discounting assessment modality. PMID:27450931

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bambha, Ray P.; Michelsen, Hope A.

    We have used a Single-Particle Soot Photometer (SP2) to measure time-resolved laser-induced incandescence (LII) and laser scatter from combustion-generated mature soot with a fractal dimension of 1.88 extracted from a burner. We have also made measurements on restructured mature-soot particles with a fractal dimension of 2.3–2.4. We reproduced the LII and laser-scatter temporal profiles with an energy- and mass-balance model, which accounted for heating of particles passed through a CW-laser beam over laser–particle interaction times of ~10 μs. Furthermore, the results demonstrate a strong influence of aggregate size and morphology on LII and scattering signals. Conductive cooling competes with absorptivemore » heating on these time scales; the effects are reduced with increasing aggregate size and fractal dimension. These effects can lead to a significant delay in the onset of the LII signal and may explain an apparent low bias in the SP2 measurements for small particle sizes, particularly for fresh, mature soot. The results also reveal significant perturbations to the measured scattering signal from LII interference and suggest rapid expansion of the aggregates during sublimation.« less

  7. Primary and Aggregate Size Distributions of PM in Tail Pipe Emissions form Diesel Engines

    NASA Astrophysics Data System (ADS)

    Arai, Masataka; Amagai, Kenji; Nakaji, Takayuki; Hayashi, Shinji

    Particulate matter (PM) emission exhausted from diesel engine should be reduced to keep the clean air environment. PM emission was considered that it consisted of coarse and aggregate particles, and nuclei-mode particles of which diameter was less than 50nm. However the detail characteristics about these particles of the PM were still unknown and they were needed for more physically accurate measurement and more effective reduction of exhaust PM emission. In this study, the size distributions of solid particles in PM emission were reported. PMs in the tail-pipe emission were sampled from three type diesel engines. Sampled PM was chemically treated to separate the solid carbon fraction from other fractions such as soluble organic fraction (SOF). The electron microscopic and optical-manual size measurement procedures were used to determine the size distribution of primary particles those were formed through coagulation process from nuclei-mode particles and consisted in aggregate particles. The centrifugal sedimentation method was applied to measure the Stokes diameter of dry-soot. Aerodynamic diameters of nano and aggregate particles were measured with scanning mobility particle sizer (SMPS). The peak aggregate diameters detected by SMPS were fallen in the same size regime as the Stokes diameter of dry-soot. Both of primary and Stokes diameters of dry-soot decreased with increases of engine speed and excess air ratio. Also, the effects of fuel properties and engine types on primary and aggregate particle diameters were discussed.

  8. Influence of the weighing bar position in vessel on measurement of cement’s particle size distribution by using the buoyancy weighing-bar method

    NASA Astrophysics Data System (ADS)

    Tambun, R.; Sihombing, R. O.; Simanjuntak, A.; Hanum, F.

    2018-02-01

    The buoyancy weighing-bar method is a new simple and cost-effective method to determine the particle size distribution both settling and floating particle. In this method, the density change in a suspension due to particle migration is measured by weighing buoyancy against a weighing-bar hung in the suspension, and then the particle size distribution is calculated using the length of the bar and the time-course change in the mass of the bar. The apparatus of this method consists of a weighing-bar and an analytical balance with a hook for under-floor weighing. The weighing bar is used to detect the density change in suspension. In this study we investigate the influences of position of weighing bar in vessel on settling particle size distribution measurements of cement by using the buoyancy weighing-bar method. The vessel used in this experiment is graduated cylinder with the diameter of 65 mm and the position of weighing bar is in center and off center of vessel. The diameter of weighing bar in this experiment is 10 mm, and the kerosene is used as a dispersion liquids. The results obtained show that the positions of weighing bar in vessel have no significant effect on determination the cement’s particle size distribution by using buoyancy weighing-bar method, and the results obtained are comparable to those measured by using settling balance method.

  9. The consequences of perceived discrimination for psychological well-being: a meta-analytic review.

    PubMed

    Schmitt, Michael T; Branscombe, Nyla R; Postmes, Tom; Garcia, Amber

    2014-07-01

    In 2 meta-analyses, we examined the relationship between perceived discrimination and psychological well-being and tested a number of moderators of that relationship. In Meta-Analysis 1 (328 independent effect sizes, N = 144,246), we examined correlational data measuring both perceived discrimination and psychological well-being (e.g., self-esteem, depression, anxiety, psychological distress, life satisfaction). Using a random-effects model, the mean weighted effect size was significantly negative, indicating harm (r = -.23). Effect sizes were larger for disadvantaged groups (r = -.24) compared to advantaged groups (r = -.10), larger for children compared to adults, larger for perceptions of personal discrimination compared to group discrimination, and weaker for racism and sexism compared to other stigmas. The negative relationship was significant across different operationalizations of well-being but was somewhat weaker for positive outcomes (e.g., self-esteem, positive affect) than for negative outcomes (e.g., depression, anxiety, negative affect). Importantly, the effect size was significantly negative even in longitudinal studies that controlled for prior levels of well-being (r = -.15). In Meta-Analysis 2 (54 independent effect sizes, N = 2,640), we examined experimental data from studies manipulating perceptions of discrimination and measuring well-being. We found that the effect of discrimination on well-being was significantly negative for studies that manipulated general perceptions of discrimination (d = -.25), but effects did not differ from 0 when attributions to discrimination for a specific negative event were compared to personal attributions (d = .06). Overall, results support the idea that the pervasiveness of perceived discrimination is fundamental to its harmful effects on psychological well-being. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  10. Study on improving the turbidity measurement of the absolute coagulation rate constant.

    PubMed

    Sun, Zhiwei; Liu, Jie; Xu, Shenghua

    2006-05-23

    The existing theories dealing with the evaluation of the absolute coagulation rate constant by turbidity measurement were experimentally tested for different particle-sized (radius = a) suspensions at incident wavelengths (lambda) ranging from near-infrared to ultraviolet light. When the size parameter alpha = 2pi a/lambda > 3, the rate constant data from previous theories for fixed-sized particles show significant inconsistencies at different light wavelengths. We attribute this problem to the imperfection of these theories in describing the light scattering from doublets through their evaluation of the extinction cross section. The evaluations of the rate constants by all previous theories become untenable as the size parameter increases and therefore hampers the applicable range of the turbidity measurement. By using the T-matrix method, we present a robust solution for evaluating the extinction cross section of doublets formed in the aggregation. Our experiments show that this new approach is effective in extending the applicability range of the turbidity methodology and increasing measurement accuracy.

  11. Immobilization thresholds of electrofishing relative to fish size

    USGS Publications Warehouse

    Dolan, C.R.; Miranda, L.E.

    2003-01-01

    Fish size and electrical waveforms have frequently been associated with variation in electrofishing effectiveness. Under controlled laboratory conditions, we measured the electrical power required by five electrical waveforms to immobilize eight fish species of diverse sizes and shapes. Fish size was indexed by total body length, surface area, volume, and weight; shape was indexed by the ratio of body length to body depth. Our objectives were to identify immobilization thresholds, elucidate the descriptors of fish size that were best associated with those immobilization thresholds, and determine whether the vulnerability of a species relative to other species remained constant across electrical treatments. The results confirmed that fish size is a key variable controlling the immobilization threshold and further suggested that the size descriptor best related to immobilization is fish volume. The peak power needed to immobilize fish decreased rapidly with increasing fish volume in small fish but decreased slowly for fish larger than 75-100 cm 3. Furthermore, when we controlled for size and shape, different waveforms did not favor particular species, possibly because of the overwhelming effect of body size. Many of the immobilization inconsistencies previously attributed to species might simply represent the effect of disparities in body size.

  12. Analysis and testing of a new method for drop size measurement using laser scatter interferometry

    NASA Technical Reports Server (NTRS)

    Bachalo, W. D.; Houser, M. J.

    1984-01-01

    Research was conducted on a laser light scatter detection method for measuring the size and velocity of spherical particles. The method is based upon the measurement of the interference fringe pattern produced by spheres passing through the intersection of two laser beams. A theoretical analysis of the method was carried out using the geometrical optics theory. Experimental verification of the theory was obtained by using monodisperse droplet streams. Several optical configurations were tested to identify all of the parametric effects upon the size measurements. Both off-axis forward and backscatter light detection were utilized. Simulated spray environments and fuel spray nozzles were used in the evaluation of the method. The measurements of the monodisperse drops showed complete agreement with the theoretical predictions. The method was demonstrated to be independent of the beam intensity and extinction resulting from the surrounding drops. Signal processing concepts were considered and a method was selected for development.

  13. A Regression Framework for Effect Size Assessments in Longitudinal Modeling of Group Differences

    PubMed Central

    Feingold, Alan

    2013-01-01

    The use of growth modeling analysis (GMA)--particularly multilevel analysis and latent growth modeling--to test the significance of intervention effects has increased exponentially in prevention science, clinical psychology, and psychiatry over the past 15 years. Model-based effect sizes for differences in means between two independent groups in GMA can be expressed in the same metric (Cohen’s d) commonly used in classical analysis and meta-analysis. This article first reviews conceptual issues regarding calculation of d for findings from GMA and then introduces an integrative framework for effect size assessments that subsumes GMA. The new approach uses the structure of the linear regression model, from which effect sizes for findings from diverse cross-sectional and longitudinal analyses can be calculated with familiar statistics, such as the regression coefficient, the standard deviation of the dependent measure, and study duration. PMID:23956615

  14. Self-pollination rate and floral-display size in Asclepias syriaca (Common Milkweed) with regard to floral-visitor taxa.

    PubMed

    Howard, Aaron F; Barrows, Edward M

    2014-06-23

    Animals fertilize thousands of angiosperm species whose floral-display sizes can significantly influence pollinator behavior and plant reproductive success. Many studies have measured the interactions among pollinator behavior, floral-display size, and plant reproductive success, but few studies have been able to separate the effects of pollinator behavior and post-pollination processes on angiosperm sexual reproduction. In this study, we utilized the highly self-incompatible pollinium-pollination system of Asclepias syriaca (Common Milkweed) to quantify how insect visitors influenced male reproductive success measured as pollen removal, female reproductive success measured as pollen deposition, and self-pollination rate. We also determined how floral-display size impacts both visitor behavior and self-pollination rate. Four insect taxonomic orders visited A. syriaca: Coleoptera, Diptera, Hymenoptera, and Lepidoptera. We focused on three groups of visitor taxa within two orders (Hymenoptera and Lepidoptera) with sample sizes large enough for quantitative analysis: Apis mellifera (Western Honey Bee), Bombus spp. (bumble bees) and lepidopterans (butterflies and moths). Qualitatively, lepidopterans had the highest pollinator importance values, but the large variability in the lepidopteran data precluded meaningful interpretation of much of their behavior. The introduced A. mellifera was the most effective and most important diurnal pollinator with regard to both pollen removal and pollen deposition. However, when considering the self-incompatibility of A. syriaca, A. mellifera was not the most important pollinator because of its high self-pollination rate as compared to Bombus spp. Additionally, the rate of self-pollination increased more rapidly with the number of flowers per inflorescence in A. mellifera than in the native Bombus spp. Apis mellifera's high rate of self-pollination may have significant negative effects on both male and female reproductive successes in A. syriaca, causing different selection on floral-display size than native pollinators.

  15. Little effect of climate change on body size of herbivorous beetles.

    PubMed

    Baar, Yuval; Friedman, Ariel Leib Leonid; Meiri, Shai; Scharf, Inon

    2018-04-01

    Ongoing climate change affects various aspects of an animal's life, with important effects on distribution range and phenology. The relationship between global warming and body size changes in mammals and birds has been widely studied, with most findings indicating a decline in body size over time. Nevertheless, little data exist on similar size change patterns of invertebrates in general and insects in particular, and it is unclear whether insects should decrease in size or not with climate warming. We measured over 4000 beetle specimens, belonging to 29 beetle species in 8 families, collected in Israel during the last 100 years. The sampled species are all herbivorous. We examined whether beetle body size had changed over the years, while also investigating the relationships between body size and annual temperature, precipitation, net primary productivity (NPP) at the collection site and collection month. None of the environmental variables, including the collection year, was correlated with the size of most of the studied beetle species, while there were strong interactions of all variables with species. Our results, though mostly negative, suggest that the effect of climate change on insect body size is species-specific and by no means a general macro-ecological rule. They also suggest that the intrapopulation variance in body size of insects collected as adults in the field is large enough to conceal intersite environmental effects on body size, such as the effect of temperature and NPP. © 2016 Institute of Zoology, Chinese Academy of Sciences.

  16. The international food unit: a new measurement aid that can improve portion size estimation.

    PubMed

    Bucher, T; Weltert, M; Rollo, M E; Smith, S P; Jia, W; Collins, C E; Sun, M

    2017-09-12

    Portion size education tools, aids and interventions can be effective in helping prevent weight gain. However consumers have difficulties in estimating food portion sizes and are confused by inconsistencies in measurement units and terminologies currently used. Visual cues are an important mediator of portion size estimation, but standardized measurement units are required. In the current study, we present a new food volume estimation tool and test the ability of young adults to accurately quantify food volumes. The International Food Unit™ (IFU™) is a 4x4x4 cm cube (64cm 3 ), subdivided into eight 2 cm sub-cubes for estimating smaller food volumes. Compared with currently used measures such as cups and spoons, the IFU™ standardizes estimation of food volumes with metric measures. The IFU™ design is based on binary dimensional increments and the cubic shape facilitates portion size education and training, memory and recall, and computer processing which is binary in nature. The performance of the IFU™ was tested in a randomized between-subject experiment (n = 128 adults, 66 men) that estimated volumes of 17 foods using four methods; the IFU™ cube, a deformable modelling clay cube, a household measuring cup or no aid (weight estimation). Estimation errors were compared between groups using Kruskall-Wallis tests and post-hoc comparisons. Estimation errors differed significantly between groups (H(3) = 28.48, p < .001). The volume estimations were most accurate in the group using the IFU™ cube (Mdn = 18.9%, IQR = 50.2) and least accurate using the measuring cup (Mdn = 87.7%, IQR = 56.1). The modelling clay cube led to a median error of 44.8% (IQR = 41.9). Compared with the measuring cup, the estimation errors using the IFU™ were significantly smaller for 12 food portions and similar for 5 food portions. Weight estimation was associated with a median error of 23.5% (IQR = 79.8). The IFU™ improves volume estimation accuracy compared to other methods. The cubic shape was perceived as favourable, with subdivision and multiplication facilitating volume estimation. Further studies should investigate whether the IFU™ can facilitate portion size training and whether portion size education using the IFU™ is effective and sustainable without the aid. A 3-dimensional IFU™ could serve as a reference object for estimating food volume.

  17. The effect of reducing alfalfa haylage particle size on cows in early lactation.

    PubMed

    Kononoff, P J; Heinrichs, A J

    2003-04-01

    The objective of this experiment was to evaluate effects of reducing forage particle size on cows in early lactation based on measurements of the Penn State Particle Separator (PSPS). Eight cannulated, multiparous cows averaging 19 +/- 4 d in milk and 642 +/- 45 kg BW were assigned to one of two 4 x 4 Latin Squares. During each of the 23-d periods, animals were offered one of four diets, which were chemically identical but included alfalfa haylage of different particle size; short (SH), mostly short (MSH), mostly long (MLG), and long (LG). Physically effective neutral detergent fiber (peNDF) was determined by measuring the amount of neutral detergent fiber retained on a 1.18 mm screen and was similar across diets (25.7, 26.2, 26.4, 26.7%) but the amount of particles >19.0 mm significantly decreased with decreasing particle size. Reducing haylage particle size increased dry matter intake linearly (23.3, 22.0, 20.9, 20.8 kg for SH, MSH, MLG, LG, respectively). Milk production and percentage fat did not differ across treatments averaging 35.5 +/- 0.68 kg milk and 3.32 +/- 0.67% fat, while a quadratic effect was observed for percent milk protein, with lowest values being observed for LG. A quadratic effect was observed for mean rumen pH (6.04, 6.15, 6.13, 6.09), while A:P ratio decreased linearly (2.75, 2.86, 2.88, 2.92) with decreasing particle size. Total time ruminating increased quadratically (467, 498, 486, 468 min/d), while time eating decreased linearly (262, 253, 298, 287 min/d) with decreasing particle size. Both eating and ruminating per unit of neutral detergent fiber intake decreased with reducing particle size (35.8, 36.7, 44.9, 45.6 min/kg; 19.9, 23.6, 23.5, 23.5 min/kg). Although chewing activity was closely related to forage particle size, effects on rumen pH were small, indicating factors other than particle size are critical in regulating pH when ration neutral detergent fiber met recommended levels. Feeding alfalfa haylage based rations of reduced particle size resulted in animals consuming more feed but did not affect milk production.

  18. Factors affecting plant growth in membrane nutrient delivery

    NASA Technical Reports Server (NTRS)

    Dreschel, T. W.; Wheeler, R. M.; Sager, J. C.; Knott, W. M.

    1990-01-01

    The development of the tubular membrane plant growth unit for the delivery of water and nutrients to roots in microgravity has recently focused on measuring the effects of changes in physical variables controlling solution availability to the plants. Significant effects of membrane pore size and the negative pressure used to contain the solution were demonstrated. Generally, wheat grew better in units with a larger pore size but equal negative pressure and in units with the same pore size but less negative pressure. Lettuce also exhibited better plant growth at less negative pressure.

  19. THE EFFECT OF PROJECTION ON DERIVED MASS-SIZE AND LINEWIDTH-SIZE RELATIONSHIPS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shetty, Rahul; Kauffmann, Jens; Goodman, Alyssa A.

    2010-04-01

    Power-law mass-size and linewidth-size correlations, two of 'Larson's laws', are often studied to assess the dynamical state of clumps within molecular clouds. Using the result of a hydrodynamic simulation of a molecular cloud, we investigate how geometric projection may affect the derived Larson relationships. We find that large-scale structures in the column density map have similar masses and sizes to those in the three-dimensional simulation (position-position-position, PPP). Smaller scale clumps in the column density map are measured to be more massive than the PPP clumps, due to the projection of all emitting gas along lines of sight. Further, due tomore » projection effects, structures in a synthetic spectral observation (position-position-velocity, PPV) may not necessarily correlate with physical structures in the simulation. In considering the turbulent velocities only, the linewidth-size relationship in the PPV cube is appreciably different from that measured from the simulation. Including thermal pressure in the simulated line widths imposes a minimum line width, which results in a better agreement in the slopes of the linewidth-size relationships, though there are still discrepancies in the offsets, as well as considerable scatter. Employing commonly used assumptions in a virial analysis, we find similarities in the computed virial parameters of the structures in the PPV and PPP cubes. However, due to the discrepancies in the linewidth-size and mass-size relationships in the PPP and PPV cubes, we caution that applying a virial analysis to observed clouds may be misleading due to geometric projection effects. We speculate that consideration of physical processes beyond kinetic and gravitational pressure would be required for accurately assessing whether complex clouds, such as those with highly filamentary structure, are bound.« less

  20. A meta-analysis of multicultural competencies and psychotherapy process and outcome.

    PubMed

    Tao, Karen W; Owen, Jesse; Pace, Brian T; Imel, Zac E

    2015-07-01

    For decades, psychologists have emphasized the provision of multiculturally competent psychotherapy to reduce racial and ethnic disparities in mental health treatment. However, the relationship between multicultural competencies (MC) and other measures of clinical process and treatment outcome has shown heterogeneity in effect sizes. This meta-analysis tested the association of client ratings of therapist MC with measures of therapeutic processes and outcome, including: (a) working alliance, (b) client satisfaction, (c) general counseling competence, (d) session impact, and (e) symptom improvement. Among 18 studies (20 independent samples) included in the analysis, the correlation between therapist MC and outcome (r = .29) was much smaller than the association with process measures (r = .75), but there were no significant differences in correlations across different types of MC or clinical process measures. Providing some evidence of publication bias, effect sizes from published studies (r = .67) were larger than those from unpublished dissertations (r = .28). Moderator analyses indicated that client age, gender, the representation of racial-ethnic minority (R-EM) clients, and clinical setting were not associated with effect size variability. Based on these findings, we discuss implications and recommendations for future research that might lead to a better understanding of the effects of therapist MC on treatment process and outcome. Primary needs in future research include the development and evaluation of observer ratings of therapist MC and the implementation of longitudinal research designs. (c) 2015 APA, all rights reserved).

  1. Racial discrimination and cortisol output: A meta-analysis.

    PubMed

    Korous, Kevin M; Causadias, José M; Casper, Deborah M

    2017-11-01

    Although the relation between stress and physiology is well documented, attempts at understanding the link between racial discrimination and cortisol output, specifically, have produced mixed results, likely due to study characteristics such as racial/ethnic composition of the samples (e.g., African American, Latino), measures of discrimination, and research design (e.g., cross-sectional, experimental). To estimate the overall association between racial discrimination and cortisol output among racial/ethnic minority individuals and to determine if the association between racial discrimination and cortisol output is moderated by age, race/ethnicity, type of discrimination measure, sex, and research design. Using a random effects model, the overall effect size based on k = 16 studies (19% unpublished) and N = 1506 participants was r¯ = 0.040, 95% CI = -0.038 to 0.117. Studies were conducted predominantly in the U.S. (81%). Notably, experimental studies (r¯ = 0.267) exhibited larger effect sizes compared to non-experimental studies (r¯ = -0.007). Age, race/ethnicity, type of discrimination measure, and sex did not moderate the effect sizes. This meta-analysis provides evidence that the measurement of the association between racial discrimination and cortisol is complex, and it offers valuable insight regarding methods and designs that can inform future research on this topic. Limitations and future directions are discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Men, women…who cares? A population-based study on sex differences and gender roles in empathy and moral cognition

    PubMed Central

    Baez, Sandra; Flichtentrei, Daniel; Prats, María; Mastandueno, Ricardo; García, Adolfo M.; Cetkovich, Marcelo

    2017-01-01

    Research on sex differences in empathy has revealed mixed findings. Whereas experimental and neuropsychological measures show no consistent sex effect, self-report data consistently indicates greater empathy in women. However, available results mainly come from separate populations with relatively small samples, which may inflate effect sizes and hinder comparability between both empirical corpora. To elucidate the issue, we conducted two large-scale studies. First, we examined whether sex differences emerge in a large population-based sample (n = 10,802) when empathy is measured with an experimental empathy-for-pain paradigm. Moreover, we investigated the relationship between empathy and moral judgment. In the second study, a subsample (n = 334) completed a self-report empathy questionnaire. Results showed some sex differences in the experimental paradigm, but with minuscule effect sizes. Conversely, women did portray themselves as more empathic through self-reports. In addition, utilitarian responses to moral dilemmas were less frequent in women, although these differences also had small effect sizes. These findings suggest that sex differences in empathy are highly driven by the assessment measure. In particular, self-reports may induce biases leading individuals to assume gender-role stereotypes. Awareness of the role of measurement instruments in this field may hone our understanding of the links between empathy, sex differences, and gender roles. PMID:28632770

  3. Velocity and size of droplets in dense region of diesel fuel spray on transient needle opening condition

    NASA Astrophysics Data System (ADS)

    Ueki, Hironobu; Ishida, Masahiro; Sakaguchi, Daisaku

    2005-06-01

    In order to investigate the effect of transient needle opening on early stage of spray behavior, simultaneous measurements of velocity and size of droplet were conducted by a newly developed laser 2-focus velocimeter (L2F). The micro-scale probe of the L2F was consisted of two foci with a distance of 36 µm. The tested nozzle had a single hole with a diameter of 0.2 mm. The measurements of injection pressure, needle lift, and crank angle were synchronized with the spray measurement by the L2F at the position 10 mm downstream from the nozzle exit. It has been clearly shown that the velocity and size of droplet increase with needle valve opening and that the probability density distribution of droplet size can be fitted to the Nukiyama-Tanasawa distribution under the transient needle opening condition.

  4. The impact of multiple endpoint dependency on Q and I(2) in meta-analysis.

    PubMed

    Thompson, Christopher Glen; Becker, Betsy Jane

    2014-09-01

    A common assumption in meta-analysis is that effect sizes are independent. When correlated effect sizes are analyzed using traditional univariate techniques, this assumption is violated. This research assesses the impact of dependence arising from treatment-control studies with multiple endpoints on homogeneity measures Q and I(2) in scenarios using the unbiased standardized-mean-difference effect size. Univariate and multivariate meta-analysis methods are examined. Conditions included different overall outcome effects, study sample sizes, numbers of studies, between-outcomes correlations, dependency structures, and ways of computing the correlation. The univariate approach used typical fixed-effects analyses whereas the multivariate approach used generalized least-squares (GLS) estimates of a fixed-effects model, weighted by the inverse variance-covariance matrix. Increased dependence among effect sizes led to increased Type I error rates from univariate models. When effect sizes were strongly dependent, error rates were drastically higher than nominal levels regardless of study sample size and number of studies. In contrast, using GLS estimation to account for multiple-endpoint dependency maintained error rates within nominal levels. Conversely, mean I(2) values were not greatly affected by increased amounts of dependency. Last, we point out that the between-outcomes correlation should be estimated as a pooled within-groups correlation rather than using a full-sample estimator that does not consider treatment/control group membership. Copyright © 2014 John Wiley & Sons, Ltd.

  5. Effects of Lifting Method, Seedling Size, and Herbaceous Weed Control on First-Year Growth of Loblolly Pine Seedlings

    Treesearch

    Jason P. Reynolds; Thomas A. Greene; John R. Britt

    2002-01-01

    In fall, 1999, an experiment was installed to measure the effects and interactions of lifting method, seedling size, and weed competition on growth of loblolly pine (P. teada) seedlings during the first two growing seasons. Loblolly pine seedlings grown at two bed densities and lifted either by hand or machine were planted in southwestern Georgia...

  6. A Meta-Analysis of Gender Differences in Terms of Teacher Views on the Instructional Leadership Behavior of Principals

    ERIC Educational Resources Information Center

    Kis, Ali; Konan, Necdet

    2014-01-01

    The main aim of this study was to gather teachers' views to determine the effect size of gender differences on the instructional leadership behavior of school principals. The standardized mean difference (SMD) was calculated to measure the effect size in this study. An initial search yielded 126 studies on the research topic, which consists…

  7. A theoretical and experimental study of turbulent nonevaporating sprays

    NASA Technical Reports Server (NTRS)

    Solomon, A. S. P.; Shuen, J. S.; Zhang, Q. F.; Faeth, G. M.

    1984-01-01

    Measurements and analysis limited to the dilute portions of turbulent nonevaporating sprays injected into a still air environment were completed. Mean and fluctuating velocities and Reynolds stress were measured in the continuous phase. Liquid phase measurements included liquid mass fluxes, drop sizes and drop size and velocity correlation. Initial conditions needed for model evaluation were measured at a location as close to the injector exit as possible. The test sprays showed significant effects of slip and turbulent dispersion of the discrete phase. The measurements were used to evaluate three typical models of these processes: (1) a locally homogenous flow (LHF) model, where slip between the phases were neglected; (2) a deterministic separated flow (DSF) model, where slip was considered but effects of drop dispersion by turbulence were ignored; and (3) a stochastic separated flow (SSF) model, where effects of interphase slip and turbulent dispersion were considered using random-walk computations for drop motion. The LHF and DSF models did not provide very satisfactory predictions for the present measurements. In contrast, the SSF model performed reasonably well with no modifications in the prescription of eddy properties from its original calibration. Some effects of drops on turbulence properties were observed near the dense regions of the sprays.

  8. 16 CFR 1509.9 - Mattresses.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... effective crib-side height dimension of at least 50.8 centimeters (20 inches) as measured from the upper... effective crib-side height dimension of at least 7.6 centimeters (3 inches) as measured from the upper... position. (b) Mattress dimensions. The dimensions of a mattress supplied with a non-full-size baby crib...

  9. 16 CFR 1509.9 - Mattresses.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... effective crib-side height dimension of at least 50.8 centimeters (20 inches) as measured from the upper... effective crib-side height dimension of at least 7.6 centimeters (3 inches) as measured from the upper... position. (b) Mattress dimensions. The dimensions of a mattress supplied with a non-full-size baby crib...

  10. 10 CFR 436.18 - Measuring cost-effectiveness.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... water system, considered in determining such matters as the optimal size of a solar energy system, the... 10 Energy 3 2012-01-01 2012-01-01 false Measuring cost-effectiveness. 436.18 Section 436.18 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...

  11. 10 CFR 436.18 - Measuring cost-effectiveness.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... water system, considered in determining such matters as the optimal size of a solar energy system, the... 10 Energy 3 2014-01-01 2014-01-01 false Measuring cost-effectiveness. 436.18 Section 436.18 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...

  12. 10 CFR 436.18 - Measuring cost-effectiveness.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... water system, considered in determining such matters as the optimal size of a solar energy system, the... 10 Energy 3 2013-01-01 2013-01-01 false Measuring cost-effectiveness. 436.18 Section 436.18 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION FEDERAL ENERGY MANAGEMENT AND PLANNING PROGRAMS Methodology and...

  13. Virtual reality measures in neuropsychological assessment: a meta-analytic review.

    PubMed

    Neguț, Alexandra; Matu, Silviu-Andrei; Sava, Florin Alin; David, Daniel

    2016-02-01

    Virtual reality-based assessment is a new paradigm for neuropsychological evaluation, that might provide an ecological assessment, compared to paper-and-pencil or computerized neuropsychological assessment. Previous research has focused on the use of virtual reality in neuropsychological assessment, but no meta-analysis focused on the sensitivity of virtual reality-based measures of cognitive processes in measuring cognitive processes in various populations. We found eighteen studies that compared the cognitive performance between clinical and healthy controls on virtual reality measures. Based on a random effects model, the results indicated a large effect size in favor of healthy controls (g = .95). For executive functions, memory and visuospatial analysis, subgroup analysis revealed moderate to large effect sizes, with superior performance in the case of healthy controls. Participants' mean age, type of clinical condition, type of exploration within virtual reality environments, and the presence of distractors were significant moderators. Our findings support the sensitivity of virtual reality-based measures in detecting cognitive impairment. They highlight the possibility of using virtual reality measures for neuropsychological assessment in research applications, as well as in clinical practice.

  14. Investigation of specimen size effects by in-situ microcompression of equal channel angular pressed copper

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Howard, C.; Frazer, D.; Lupinacci, A.

    Here, micropillar compression testing was implemented on Equal Channel Angular Pressed copper samples ranging from 200 nm to 10 µm in side length in order to measure the mechanical properties yield strength, first load drop during plastic deformation at which there was a subsequent stress decrease with increasing strain, work hardening, and strain hardening exponent. Several micropillars containing multiple grains were investigated in a 200 nm grain sample. The effective pillar diameter to grain size ratios, D/d, were measured to be between 1.9 and 27.2. Specimens having D/d ratios between 0.2 and 5 were investigated in a second sample thatmore » was annealed at 200 °C for 2 h with an average grain size of 1.3 µm. No yield strength or elastic modulus size effects were observed in specimens in the 200 nm grain size sample. However work hardening increases with a decrease in critical ratios and first stress drops occur at much lower stresses for specimens with D/d ratios less than 5. For comparison, bulk tensile testing of both samples was performed, and the yield strength values of all micropillar compression tests for the 200 nm grained sample are in good agreement with the yield strength values of the tensile tests.« less

  15. Investigation of specimen size effects by in-situ microcompression of equal channel angular pressed copper

    DOE PAGES

    Howard, C.; Frazer, D.; Lupinacci, A.; ...

    2015-09-30

    Here, micropillar compression testing was implemented on Equal Channel Angular Pressed copper samples ranging from 200 nm to 10 µm in side length in order to measure the mechanical properties yield strength, first load drop during plastic deformation at which there was a subsequent stress decrease with increasing strain, work hardening, and strain hardening exponent. Several micropillars containing multiple grains were investigated in a 200 nm grain sample. The effective pillar diameter to grain size ratios, D/d, were measured to be between 1.9 and 27.2. Specimens having D/d ratios between 0.2 and 5 were investigated in a second sample thatmore » was annealed at 200 °C for 2 h with an average grain size of 1.3 µm. No yield strength or elastic modulus size effects were observed in specimens in the 200 nm grain size sample. However work hardening increases with a decrease in critical ratios and first stress drops occur at much lower stresses for specimens with D/d ratios less than 5. For comparison, bulk tensile testing of both samples was performed, and the yield strength values of all micropillar compression tests for the 200 nm grained sample are in good agreement with the yield strength values of the tensile tests.« less

  16. Twomey Effect in Subtropical Stratocumulus Clouds from UV Depolarization LIDAR

    NASA Astrophysics Data System (ADS)

    de Graaf, Martin; Brown, Jessica; Donovan, David

    2018-04-01

    Marine stratocumulus clouds are important climate regulators, reflecting sunlight over a dark ocean background. A UV-depolarization lidar on Ascension, a small remote island in the south Atlantic, measured cloud droplet sizes and number concentration using an inversion method based on Monte Carlo (MC) modelling of multiple scattering in idealised semiadiabatic clouds. The droplet size and number concentration weremodulated due to smoke from the African continent, measured by the same instrument.

  17. Measurement of cervical flexor endurance following whiplash.

    PubMed

    Kumbhare, Dinesh A; Balsor, Brad; Parkinson, William L; Harding Bsckin, Peter; Bedard, Michel; Papaioannou, Alexandra; Adachi, Jonathan D

    2005-07-22

    To investigate measurement properties of a practical test of cervical flexor endurance (CFE) in whiplash patients including inter-rater reliability, sensitivity to clinical change, criterion related validity against the Neck Disability Index (NDI), and discriminant validity for injured versus uninjured populations. Two samples were recruited, 81 whiplash patients, and a convenience sample of 160 subjects who were not seeking treatment and met criteria for normal pain and range of motion. CFE was measured using a stopwatch while the subject, in crook lying, held their head against gravity to fatigue. Inter-rater reliability in whiplash patients was in a range considered 'almost perfect' (Intraclass Correlation=0.96). CFE had greater inter-subject variability than the NDI or range of motion in any of three planes. However, the effect size for improvement in CFE over treatment was as large as the effect sizes for all of those measures. In multivariate regression, CFE changes accounted for changes on the NDI better than the three ranges of motion. CFE discriminated whiplash patients who were within six months of injury (n=71) from age and gender matched normals with high effect size (ES=1.5). These findings provide evidence of reliability and validity for CFE measurement, and demonstrate that CFE detects clinical improvements. Variance on CFE emphasizes the need to consider inter-, and intra-subject standard deviations to interpret scores.

  18. Measurement of effective air diffusion coefficients for trichloroethene in undisturbed soil cores.

    PubMed

    Bartelt-Hunt, Shannon L; Smith, James A

    2002-06-01

    In this study, we measure effective diffusion coefficients for trichloroethene in undisturbed soil samples taken from Picatinny Arsenal, New Jersey. The measured effective diffusion coefficients ranged from 0.0053 to 0.0609 cm2/s over a range of air-filled porosity of 0.23-0.49. The experimental data were compared to several previously published relations that predict diffusion coefficients as a function of air-filled porosity and porosity. A multiple linear regression analysis was developed to determine if a modification of the exponents in Millington's [Science 130 (1959) 100] relation would better fit the experimental data. The literature relations appeared to generally underpredict the effective diffusion coefficient for the soil cores studied in this work. Inclusion of a particle-size distribution parameter, d10, did not significantly improve the fit of the linear regression equation. The effective diffusion coefficient and porosity data were used to recalculate estimates of diffusive flux through the subsurface made in a previous study performed at the field site. It was determined that the method of calculation used in the previous study resulted in an underprediction of diffusive flux from the subsurface. We conclude that although Millington's [Science 130 (1959) 100] relation works well to predict effective diffusion coefficients in homogeneous soils with relatively uniform particle-size distributions, it may be inaccurate for many natural soils with heterogeneous structure and/or non-uniform particle-size distributions.

  19. Effect of Processing Parameters on the Physical, Thermal, and Combustion Properties of Plasma-Synthesized Aluminum Nanopowders

    DTIC Science & Technology

    2011-02-01

    only a couple of processing parameters. Table 2 Statistical results of the DOE Run no. Plasma power Feed rate System pressure Quench rate...and quench rate. Particle size was chosen as the measured response due to its predominant effect on material properties. The results of the DOE...showed that feed rate and quench rate have the largest effect on particle size. All synthesized powders were characterized by thermogravimetric

  20. Preliminary examination of the efficacy and safety of a standardized chamomile extract for chronic primary insomnia: A randomized placebo-controlled pilot study

    PubMed Central

    2011-01-01

    Background Despite being the most commonly used herbal for sleep disorders, chamomile's (Matricaria recutita) efficacy and safety for treating chronic primary insomnia is unknown. We examined the preliminary efficacy and safety of chamomile for improving subjective sleep and daytime symptoms in patients with chronic insomnia. Methods We performed a randomized, double-blind, placebo-controlled pilot trial in 34 patients aged 18-65 years with DSM-IV primary insomnia for ≥ 6-months. Patients were randomized to 270 mg of chamomile twice daily or placebo for 28-days. The primary outcomes were sleep diary measures. Secondary outcomes included daytime symptoms, safety assessments, and effect size of these measures. Results There were no significant differences between groups in changes in sleep diary measures, including total sleep time (TST), sleep efficiency, sleep latency, wake after sleep onset (WASO), sleep quality, and number of awakenings. Chamomile did show modest advantage on daytime functioning, although these did not reach statistical significance. Effect sizes were generally small to moderate (Cohen's d ≤ 0.20 to < 0.60) with sleep latency, night time awakenings, and Fatigue Severity Scale (FSS), having moderate effect sizes in favor of chamomile. However, TST demonstrated a moderate effect size in favor of placebo. There were no differences in adverse events reported by the chamomile group compared to placebo. Conclusion Chamomile could provide modest benefits of daytime functioning and mixed benefits on sleep diary measures relative to placebo in adults with chronic primary insomnia. However, further studies in select insomnia patients would be needed to investigate these conclusions. Trial Registration ClinicalTrials.gov Identifier NCT01286324 PMID:21939549

  1. Cognitive effects of two nutraceuticals Ginseng and Bacopa benchmarked against modafinil: a review and comparison of effect sizes

    PubMed Central

    Neale, Chris; Camfield, David; Reay, Jonathon; Stough, Con; Scholey, Andrew

    2013-01-01

    Over recent years there has been increasing research into both pharmaceutical and nutraceutical cognition enhancers. Here we aimed to calculate the effect sizes of positive cognitive effect of the pharmaceutical modafinil in order to benchmark the effect of two widely used nutraceuticals Ginseng and Bacopa (which have consistent acute and chronic cognitive effects, respectively). A search strategy was implemented to capture clinical studies into the neurocognitive effects of modafinil, Ginseng and Bacopa. Studies undertaken on healthy human subjects using a double‐blind, placebo‐controlled design were included. For each study where appropriate data were included, effect sizes (Cohen's d) were calculated for measures showing significant positive and negative effects of treatment over placebo. The highest effect sizes for cognitive outcomes were 0.77 for modafinil (visuospatial memory accuracy), 0.86 for Ginseng (simple reaction time) and 0.95 for Bacopa (delayed word recall). These data confirm that neurocognitive enhancement from well characterized nutraceuticals can produce cognition enhancing effects of similar magnitude to those from pharmaceutical interventions. Future research should compare these effects directly in clinical trials. PMID:23043278

  2. A Systematic Review of the Relationship between Familism and Mental Health Outcomes in Latino Population

    PubMed Central

    Valdivieso-Mora, Esmeralda; Peet, Casie L.; Garnier-Villarreal, Mauricio; Salazar-Villanea, Monica; Johnson, David K.

    2016-01-01

    Background: Familismo or familism is a cultural value frequently seen in Hispanic cultures, in which a higher emphasis is placed on the family unit in terms of respect, support, obligation, and reference. Familism has been implicated as a protective factor against mental health problems and may foster the growth and development of children. This study aims at measuring the size of the relationship between familism and mental health outcomes of depression, suicide, substance abuse, internalizing, and externalizing behaviors. Methods: Thirty-nine studies were systematically reviewed to assess the relationship between familism and mental health outcomes. Data from the studies were comprised and organized into five categories: depression, suicide, internalizing symptoms, externalizing symptoms, and substance use. The Cohen's d of each value (dependent variable in comparison to familism) was calculated. Results were weighted based on sample sizes (n) and total effect sizes were then calculated. It was hypothesized that there would be a large effect size in the relationship between familism and depression, suicide, internalizing, and externalizing symptoms and substance use in Hispanics. Results: The meta-analysis showed small effect sizes in the relationship between familism and depression, suicide and internalizing behaviors. And no significant effects for substance abuse and externalizing behaviors. Discussion: The small effects found in this study may be explained by the presence of moderator variables between familism and mental health outcomes (e.g., communication within the family). In addition, variability in the Latino samples and in the measurements used might explain the small and non-significant effects found. PMID:27826269

  3. Estimating the settling velocity of bioclastic sediment using common grain-size analysis techniques

    USGS Publications Warehouse

    Cuttler, Michael V. W.; Lowe, Ryan J.; Falter, James L.; Buscombe, Daniel D.

    2017-01-01

    Most techniques for estimating settling velocities of natural particles have been developed for siliciclastic sediments. Therefore, to understand how these techniques apply to bioclastic environments, measured settling velocities of bioclastic sedimentary deposits sampled from a nearshore fringing reef in Western Australia were compared with settling velocities calculated using results from several common grain-size analysis techniques (sieve, laser diffraction and image analysis) and established models. The effects of sediment density and shape were also examined using a range of density values and three different models of settling velocity. Sediment density was found to have a significant effect on calculated settling velocity, causing a range in normalized root-mean-square error of up to 28%, depending upon settling velocity model and grain-size method. Accounting for particle shape reduced errors in predicted settling velocity by 3% to 6% and removed any velocity-dependent bias, which is particularly important for the fastest settling fractions. When shape was accounted for and measured density was used, normalized root-mean-square errors were 4%, 10% and 18% for laser diffraction, sieve and image analysis, respectively. The results of this study show that established models of settling velocity that account for particle shape can be used to estimate settling velocity of irregularly shaped, sand-sized bioclastic sediments from sieve, laser diffraction, or image analysis-derived measures of grain size with a limited amount of error. Collectively, these findings will allow for grain-size data measured with different methods to be accurately converted to settling velocity for comparison. This will facilitate greater understanding of the hydraulic properties of bioclastic sediment which can help to increase our general knowledge of sediment dynamics in these environments.

  4. Atomoxetine Increased Effect over Time in Adults with Attention-Deficit/Hyperactivity Disorder Treated for up to 6 Months: Pooled Analysis of Two Double-Blind, Placebo-Controlled, Randomized Trials.

    PubMed

    Wietecha, Linda A; Clemow, David B; Buchanan, Andrew S; Young, Joel L; Sarkis, Elias H; Findling, Robert L

    2016-07-01

    Changes in the magnitude of efficacy throughout 26 weeks of atomoxetine treatment, along with impact of dosing, were evaluated in adults with ADHD from two randomized, double-blind, placebo-controlled studies. Pooled placebo (n = 485) and atomoxetine (n = 518) patients, dosed 25, 40, 60, 80 (target dose), or 100 mg daily, were assessed. Change from baseline in Conners' Adult ADHD Rating Scale-Investigator Rated Scale: Screening Version (CAARS) total ADHD symptoms score and Adult ADHD Investigator Symptom Rating Scale (AISRS) total score were analyzed using mixed-model repeated measures, with least squares mean change, effect size, and response rate calculated at 1, 2, 4, 8, 12, 16, 22, and 26 weeks. Decreases on CAARS for atomoxetine- versus placebo-treated patients were consistently statistically significantly greater at every time point beginning at one week (P ≤ 0.006, 0.28 effect size). By 4 weeks, comparison was -13.19 compared with -8.84 (P < 0.0001, 0.45 effect size). By 26 weeks, mean change was -15.42 versus -9.71 (0.52 effect size); increase in effect size over time was most pronounced in the 80 mg group (0.82 effect size). AISRS demonstrated similar results. Atomoxetine response rate (CAARS 50% decrease) continued to increase throughout 26 weeks. Atomoxetine treatment in adults with ADHD was associated with small effect sizes after 4 weeks and moderate effect sizes by 6 months of treatment. The data support increased effect size and response rate over time during longer-term treatment at target dose. © 2016 Eli Lilly and Company. CNS Neuroscience & Therapeutics published by John Wiley & Sons Ltd.

  5. Fetal growth in different racial groups.

    PubMed Central

    Alvear, J; Brooke, O G

    1978-01-01

    Three racial groups of mothers and their newborn babies-- North European 75, Negro 75, and "Indian" Asian 37--were matched for parity, gestational age, sex, maternal age, maternal smoking habits, and social class. Multiple anthropometric measurements, including skinfold thickness, limb circumferences, and various linear measurements were made on the mothers and their infants to determine the effects of race and smoking on fetal size. Indian-Asian mothers, though shorter and lighter than Europeans and Negroes, had similar skinfold thickness and weight: height2 ratios and gained as much weight during pregnancy. Their infants, however, were lighter than the others, and had smaller head and limb circumferences, although their linear measurements were the same. Negro and European infants were almost identical in size. We found no effect on any of the fetal measurements which could be attributed to smoking. PMID:626515

  6. Significant Effect of Pore Sizes on Energy Storage in Nanoporous Carbon Supercapacitors.

    PubMed

    Young, Christine; Lin, Jianjian; Wang, Jie; Ding, Bing; Zhang, Xiaogang; Alshehri, Saad M; Ahamad, Tansir; Salunkhe, Rahul R; Hossain, Shahriar A; Khan, Junayet Hossain; Ide, Yusuke; Kim, Jeonghun; Henzie, Joel; Wu, Kevin C-W; Kobayashi, Naoya; Yamauchi, Yusuke

    2018-04-20

    Mesoporous carbon can be synthesized with good control of surface area, pore-size distribution, and porous architecture. Although the relationship between porosity and supercapacitor performance is well known, there are no thorough reports that compare the performance of numerous types of carbon samples side by side. In this manuscript, we describe the performance of 13 porous carbon samples in supercapacitor devices. We suggest that there is a "critical pore size" at which guest molecules can pass through the pores effectively. In this context, the specific surface area (SSA) and pore-size distribution (PSD) are used to show the point at which the pore size crosses the threshold of critical size. These measurements provide a guide for the development of new kinds of carbon materials for supercapacitor devices. © 2018 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  7. Effects of Al(OH)O nanoparticle agglomerate size in epoxy resin on tension, bending, and fracture properties

    NASA Astrophysics Data System (ADS)

    Jux, Maximilian; Finke, Benedikt; Mahrholz, Thorsten; Sinapius, Michael; Kwade, Arno; Schilde, Carsten

    2017-04-01

    Several epoxy Al(OH)O (boehmite) dispersions in an epoxy resin are produced in a kneader to study the mechanistic correlation between the nanoparticle size and mechanical properties of the prepared nanocomposites. The agglomerate size is set by a targeted variation in solid content and temperature during dispersion, resulting in a different level of stress intensity and thus a different final agglomerate size during the process. The suspension viscosity was used for the estimation of stress energy in laminar shear flow. Agglomerate size measurements are executed via dynamic light scattering to ensure the quality of the produced dispersions. Furthermore, various nanocomposite samples are prepared for three-point bending, tension, and fracture toughness tests. The screening of the size effect is executed with at least seven samples per agglomerate size and test method. The variation of solid content is found to be a reliable method to adjust the agglomerate size between 138-354 nm during dispersion. The size effect on the Young's modulus and the critical stress intensity is only marginal. Nevertheless, there is a statistically relevant trend showing a linear increase with a decrease in agglomerate size. In contrast, the size effect is more dominant to the sample's strain and stress at failure. Unlike microscaled agglomerates or particles, which lead to embrittlement of the composite material, nanoscaled agglomerates or particles cause the composite elongation to be nearly of the same level as the base material. The observed effect is valid for agglomerate sizes between 138-354 nm and a particle mass fraction of 10 wt%.

  8. Correcting For Seed-Particle Lag In LV Measurements

    NASA Technical Reports Server (NTRS)

    Jones, Gregory S.; Gartrell, Luther R.; Kamemoto, Derek Y.

    1994-01-01

    Two experiments conducted to evaluate effects of sizes of seed particles on errors in LV measurements of mean flows. Both theoretical and conventional experimental methods used to evaluate errors. First experiment focused on measurement of decelerating stagnation streamline of low-speed flow around circular cylinder with two-dimensional afterbody. Second performed in transonic flow and involved measurement of decelerating stagnation streamline of hemisphere with cylindrical afterbody. Concluded, mean-quantity LV measurements subject to large errors directly attributable to sizes of particles. Predictions of particle-response theory showed good agreement with experimental results, indicating velocity-error-correction technique used in study viable for increasing accuracy of laser velocimetry measurements. Technique simple and useful in any research facility in which flow velocities measured.

  9. Physical therapy treatments for low back pain in children and adolescents: a meta-analysis

    PubMed Central

    2013-01-01

    Background Low back pain (LBP) in adolescents is associated with LBP in later years. In recent years treatments have been administered to adolescents for LBP, but it is not known which physical therapy treatment is the most efficacious. By means of a meta-analysis, the current study investigated the effectiveness of the physical therapy treatments for LBP in children and adolescents. Methods Studies in English, Spanish, French, Italian and Portuguese, and carried out by March 2011, were selected by electronic and manual search. Two independent researchers coded the moderator variables of the studies, and performed the effect size calculations. The mean effect size index used was the standardized mean change between the pretest and posttest, and it was applied separately for each combination of outcome measures, (pain, disability, flexibility, endurance and mental health) and measurement type (self-reports, and clinician assessments). Results Eight articles that met the selection criteria enabled us to define 11 treatment groups and 5 control groups using the group as the unit of analysis. The 16 groups involved a total sample of 334 subjects at the posttest (221 in the treatment groups and 113 in the control groups). For all outcome measures, the average effect size of the treatment groups was statistically and clinically significant, whereas the control groups had negative average effect sizes that were not statistically significant. Conclusions Of all the physical therapy treatments for LBP in children and adolescents, the combination of therapeutic physical conditioning and manual therapy is the most effective. The low number of studies and control groups, and the methodological limitations in this meta-analysis prevent us from drawing definitive conclusions in relation to the efficacy of physical therapy treatments in LBP. PMID:23374375

  10. Physical therapy treatments for low back pain in children and adolescents: a meta-analysis.

    PubMed

    Calvo-Muñoz, Inmaculada; Gómez-Conesa, Antonia; Sánchez-Meca, Julio

    2013-02-02

    Low back pain (LBP) in adolescents is associated with LBP in later years. In recent years treatments have been administered to adolescents for LBP, but it is not known which physical therapy treatment is the most efficacious. By means of a meta-analysis, the current study investigated the effectiveness of the physical therapy treatments for LBP in children and adolescents. Studies in English, Spanish, French, Italian and Portuguese, and carried out by March 2011, were selected by electronic and manual search. Two independent researchers coded the moderator variables of the studies, and performed the effect size calculations. The mean effect size index used was the standardized mean change between the pretest and posttest, and it was applied separately for each combination of outcome measures, (pain, disability, flexibility, endurance and mental health) and measurement type (self-reports, and clinician assessments). Eight articles that met the selection criteria enabled us to define 11 treatment groups and 5 control groups using the group as the unit of analysis. The 16 groups involved a total sample of 334 subjects at the posttest (221 in the treatment groups and 113 in the control groups). For all outcome measures, the average effect size of the treatment groups was statistically and clinically significant, whereas the control groups had negative average effect sizes that were not statistically significant. Of all the physical therapy treatments for LBP in children and adolescents, the combination of therapeutic physical conditioning and manual therapy is the most effective. The low number of studies and control groups, and the methodological limitations in this meta-analysis prevent us from drawing definitive conclusions in relation to the efficacy of physical therapy treatments in LBP.

  11. Measuring Cutaneous Lesions: Trends in Clinical Practice.

    PubMed

    Zhang, Shali; Blalock, Travis W

    2018-03-01

    Knowing the size of a cutaneous lesion can be important for tracking its progression over time, selecting the proper treatment modality, surgical planning, determining prognosis, and accurate billing. However, providers vary in their consistency, accuracy, and methods of measuring cutaneous lesions. To investigate the clinical practices of US dermatologists and dermatologic surgeons regarding how they determine the size of cutaneous lesions. A survey was electronically distributed to members of the American Society for Dermatologic Surgery. Four hundred twenty-six dermatologists completed the online survey. When a lesion is suspected to be malignant, 85% of respondents obtained exact measurements most, if not all, of the time; however, only 8% did for benign lesions. Most providers determined lesion sizes themselves rather than delegating to staff. When performing visual estimation, approximately three-quarters believed that they were accurate to within 1 to 2 mm. The top reasons for obtaining exact measurements were for tracking atypical pigmented lesions, determining treatment pathways, and accurate billing. The majority of respondents believed that lesion size affected management decisions; however, the need for exact measurement remains controversial, particularly for benign lesions. Future studies may investigate whether taking exact versus estimated measurements has an effect on outcomes.

  12. The effect of plate position and size on tibial slope in high tibial osteotomy: a cadaveric study.

    PubMed

    Rubino, L Joseph; Schoderbek, Robert J; Golish, S Raymond; Baumfeld, Joshua; Miller, Mark D

    2008-01-01

    Opening wedge high tibial osteotomies are performed for degenerative changes and varus. Opening wedge osteotomies can change proximal tibial slope in the sagittal plane, possibly imparting stability in the ACL-deficient knee. The aim of this study was to assess the effect of plate position and size on change in tibial slope. Eight cadaveric knees underwent opening wedge high tibial osteotomy with Puddu plates of each different size. Plates were placed anterior, central, and posterior for each size used. Lateral radiographs were obtained. Tibial slope was measured and compared with baseline slope. Tibial slope was affected by plate position (P < 0.05) and size (P < 0.001). Smaller, posterior plates had less effect on tibial slope. However, anterior and central plates increased tibial slope over all plate sizes (P < 0.05). This study found that tibial slope increases with opening wedge high tibial osteotomy. Larger corrections and anterior placement of the plate are associated with larger increases in slope.

  13. Grain-size-independent plastic flow at ultrahigh pressures and strain rates.

    PubMed

    Park, H-S; Rudd, R E; Cavallo, R M; Barton, N R; Arsenlis, A; Belof, J L; Blobaum, K J M; El-dasher, B S; Florando, J N; Huntington, C M; Maddox, B R; May, M J; Plechaty, C; Prisbrey, S T; Remington, B A; Wallace, R J; Wehrenberg, C E; Wilson, M J; Comley, A J; Giraldez, E; Nikroo, A; Farrell, M; Randall, G; Gray, G T

    2015-02-13

    A basic tenet of material science is that the flow stress of a metal increases as its grain size decreases, an effect described by the Hall-Petch relation. This relation is used extensively in material design to optimize the hardness, durability, survivability, and ductility of structural metals. This Letter reports experimental results in a new regime of high pressures and strain rates that challenge this basic tenet of mechanical metallurgy. We report measurements of the plastic flow of the model body-centered-cubic metal tantalum made under conditions of high pressure (>100  GPa) and strain rate (∼10(7)  s(-1)) achieved by using the Omega laser. Under these unique plastic deformation ("flow") conditions, the effect of grain size is found to be negligible for grain sizes >0.25  μm sizes. A multiscale model of the plastic flow suggests that pressure and strain rate hardening dominate over the grain-size effects. Theoretical estimates, based on grain compatibility and geometrically necessary dislocations, corroborate this conclusion.

  14. Effects of basin size on low-flow stream chemistry and subsurface contact time in the neversink river watershed, New York

    USGS Publications Warehouse

    Wolock, D.M.; Fan, J.; Lawrence, G.B.

    1997-01-01

    The effects of basin size on low-flow stream chemistry and subsurface contact time were examined for a part of the Neversink River watershed in southern New York State. Acid neutralizing capacity (ANC), the sum of base cation concentrations (SBC), pH and concentrations of total aluminum (Al), dissolved organic carbon (DOC) and silicon (Si) were measured during low stream flow at the outlets of nested basins ranging in size from 0.2 to 166.3 km2. ANC, SBC, pH, Al and DOC showed pronounced changes as basin size increased from 0.2 to 3 km2, but relatively small variations were observed as basin size increased beyond 3 km2. An index of subsurface contact time computed from basin topography and soil hydraulic conductivity also showed pronounced changes as basin size increased from 0.2 to 3 km2 and smaller changes as basin size increased beyond 3 km2. These results suggest that basin size affects low-flow stream chemistry because of the effects of basin size on subsurface contact time. ?? 1997 by John Wiley & Sons, Ltd.

  15. Effects of Rotor Blade Scaling on High-Pressure Turbine Unsteady Loading

    NASA Astrophysics Data System (ADS)

    Lastiwka, Derek; Chang, Dongil; Tavoularis, Stavros

    2013-03-01

    The present work is a study of the effects of rotor blade scaling of a single-stage high pressure turbine on the time-averaged turbine performance and on parameters that influence vibratory stresses on the rotor blades and stator vanes. Three configurations have been considered: a reference case with 36 rotor blades and 24 stator vanes, a case with blades upscaled by 12.5%, and a case with blades downscaled by 10%. The present results demonstrate that blade scaling effects were essentially negligible on the time-averaged turbine performance, but measurable on the unsteady surface pressure fluctuations, which were intensified as blade size was increased. In contrast, blade torque fluctuations increased significantly as blade size decreased. Blade scaling effects were also measurable on the vanes.

  16. Walking variations in healthy women wearing high-heeled shoes: Shoe size and heel height effects.

    PubMed

    Di Sipio, Enrica; Piccinini, Giulia; Pecchioli, Cristiano; Germanotta, Marco; Iacovelli, Chiara; Simbolotti, Chiara; Cruciani, Arianna; Padua, Luca

    2018-05-03

    The use of high heels is widespread in modern society in professional and social contests. Literature showed that wearing high heels can produce injurious effects on several structures from the toes to the pelvis. No studies considered shoe length as an impacting factor on walking with high heels. The aim of this study is to evaluate walking parameters in young healthy women wearing high heels, considering not only the heel height but also the foot/shoe size. We evaluate spatio-temporal, kinematic and kinetic data, collected using a 8-camera motion capture system, in a sample of 21 healthy women in three different walking conditions: 1) barefoot, 2) wearing 12 cm high heel shoes independently from shoe size, and 3) wearing shoes with heel height based on shoe size, keeping the ankles' plantar flexion angle constant. The main outcome measures were: spatio-temporal parameters, gait harmony measurement, range of motion, flexion and extension maximal values, power and moment of lower limb joints. Comparing the three walking conditions, the Mixed Anova test, showed significant differences between both high heeled conditions (variable and constant height) and barefoot in spatio-temporal, kinematic and kinetic parameters. Regardless of the shoe size, both heeled conditions presented a similar gait pattern and were responsible for negative effects on walking parameters. Considering our results and the relevance of the heel height, further studies are needed to identify a threshold, over which it is possible to observe that wearing high heels could cause harmful effects, independently from the foot/shoe size. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. Ultrasound during mid-gestation: Agreement with physical foetal and placental measurements and use in predicting gestational age in sheep.

    PubMed

    Jones, A K; Gately, R E; McFadden, K K; Hoffman, M L; Pillai, S M; Zinn, S A; Govoni, K E; Reed, S A

    2017-08-01

    To determine the effects of poor maternal nutrition and litter size on foetal growth during mid-gestation, pregnant ewes (n = 82) were fed 100%, 60% or 140% of NRC TDN beginning at day 30.2 ± 0.2 of gestation. Transabdominal ultrasound was performed weekly between day 46.0 ± 0.4 and 86.0 ± 0.7 to monitor foetal heart width (HW), umbilical diameter (UMB), rib width (RW) and placentome outer (OD) and inner diameter (ID). Data were analysed with repeated-measures using the mixed procedure for effects of maternal diet, litter size and gestation, and equations predictive of gestational age were generated using the regression procedure. To determine the agreement of ultrasound measurement and actual size, ewes (n = 20-21) were euthanized at day 45 or 90 to obtain corresponding postmortem measurements for Bland-Altman analysis. The HW, UMB and placentome OD and ID increased with gestation (p < .0001) but were unaffected by maternal diet or litter size (p ≥ .12). Ultrasound underestimated postmortem measurements of HW (14.8%), UMB (7.3%), placentome OD (4.5%) and ID (37.3%) at day 90 of gestation. Ultrasound underestimated RW at day 45 (7.7%) but overestimated RW (23.8%) at day 90, indicating inconsistent bias when reporting RW by ultrasound. Combining the HW, UMB, RW and placentome OD generated the strongest equation predictive of gestational age (R 2  = .91). These findings indicate that during mid-gestation, maternal diet or litter size did not affect HW, UMB or placentome diameters and these factors can be used to estimate gestational age. © 2017 Blackwell Verlag GmbH.

  18. Gemini long-slit observations of luminous obscured quasars: Further evidence for an upper limit on the size of the narrow-line region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hainline, Kevin N.; Hickox, Ryan C.; Greene, Jenny E.

    2014-05-20

    We examine the spatial extent of the narrow-line regions (NLRs) of a sample of 30 luminous obscured quasars at 0.4 < z < 0.7 observed with spatially resolved Gemini-N GMOS long-slit spectroscopy. Using the [O III] λ5007 emission feature, we estimate the size of the NLR using a cosmology-independent measurement: the radius where the surface brightness falls to 10{sup –15} erg s{sup –1} cm{sup –2} arcsec{sup –2}. We then explore the effects of atmospheric seeing on NLR size measurements and conclude that direct measurements of the NLR size from observed profiles are too large by 0.1-0.2 dex on average, asmore » compared to measurements made to best-fit Sérsic or Voigt profiles convolved with the seeing. These data, which span a full order of magnitude in IR luminosity (log (L {sub 8} {sub μm}/erg s{sup –1}) = 44.4-45.4), also provide strong evidence that there is a flattening of the relationship between NLR size and active galactic nucleus luminosity at a seeing-corrected size of ∼7 kpc. The objects in this sample have high luminosities which place them in a previously under-explored portion of the size-luminosity relationship. These results support the existence of a maximal size of the NLR around luminous quasars; beyond this size, there is either not enough gas or the gas is over-ionized and does not produce enough [O III] λ5007 emission.« less

  19. Women gaze behaviour in assessing female bodies: the effects of clothing, body size, own body composition and body satisfaction.

    PubMed

    Cundall, Amelia; Guo, Kun

    2017-01-01

    Often with minimally clothed figures depicting extreme body sizes, previous studies have shown women tend to gaze at evolutionary determinants of attractiveness when viewing female bodies, possibly for self-evaluation purposes, and their gaze distribution is modulated by own body dissatisfaction level. To explore to what extent women's body-viewing gaze behaviour is affected by clothing type, dress size, subjective measurements of regional body satisfaction and objective measurements of own body composition (e.g., chest size, body mass index, waist-to-hip ratio), in this self-paced body attractiveness and body size judgement experiment, we compared healthy, young women's gaze distributions when viewing female bodies in tight and loose clothing of different dress sizes. In contrast to tight clothing, loose clothing biased gaze away from the waist-hip to the leg region, and subsequently led to enhanced body attractiveness ratings and body size underestimation for larger female bodies, indicating the important role of clothing in mediating women's body perception. When viewing preferred female bodies, women's higher satisfaction of a specific body region was associated with an increased gaze towards neighbouring body areas, implying satisfaction might reduce the need for comparison of confident body parts; furthermore undesirable body composition measurements were correlated with a gaze avoidance process if the construct was less changeable (i.e. chest size) but a gaze comparison process if the region was more changeable (i.e. body mass index, dress size). Clearly, own body satisfaction and body composition measurements had an evident impact on women's body-viewing gaze allocation, possibly through different cognitive processes.

  20. Case studies of transportation investment to identify the impacts on the local and state economy.

    DOT National Transportation Integrated Search

    2013-01-01

    This project provides case studies of the impact of transportation investments on local economies. We use multiple : approaches to measure impacts since the effects of transportation projects can vary according to the size of a : project and the size...

  1. Sample Size and Statistical Conclusions from Tests of Fit to the Rasch Model According to the Rasch Unidimensional Measurement Model (Rumm) Program in Health Outcome Measurement.

    PubMed

    Hagell, Peter; Westergren, Albert

    Sample size is a major factor in statistical null hypothesis testing, which is the basis for many approaches to testing Rasch model fit. Few sample size recommendations for testing fit to the Rasch model concern the Rasch Unidimensional Measurement Models (RUMM) software, which features chi-square and ANOVA/F-ratio based fit statistics, including Bonferroni and algebraic sample size adjustments. This paper explores the occurrence of Type I errors with RUMM fit statistics, and the effects of algebraic sample size adjustments. Data with simulated Rasch model fitting 25-item dichotomous scales and sample sizes ranging from N = 50 to N = 2500 were analysed with and without algebraically adjusted sample sizes. Results suggest the occurrence of Type I errors with N less then or equal to 500, and that Bonferroni correction as well as downward algebraic sample size adjustment are useful to avoid such errors, whereas upward adjustment of smaller samples falsely signal misfit. Our observations suggest that sample sizes around N = 250 to N = 500 may provide a good balance for the statistical interpretation of the RUMM fit statistics studied here with respect to Type I errors and under the assumption of Rasch model fit within the examined frame of reference (i.e., about 25 item parameters well targeted to the sample).

  2. Cryogen spray cooling: Effects of droplet size and spray density on heat removal.

    PubMed

    Pikkula, B M; Torres, J H; Tunnell, J W; Anvari, B

    2001-01-01

    Cryogen spray cooling (CSC) is an effective method to reduce or eliminate non-specific injury to the epidermis during laser treatment of various dermatological disorders. In previous CSC investigations, fuel injectors have been used to deliver the cryogen onto the skin surface. The objective of this study was to examine cryogen atomization and heat removal characteristics of various cryogen delivery devices. Various cryogen delivery device types including fuel injectors, atomizers, and a device currently used in clinical settings were investigated. Cryogen mass was measured at the delivery device output orifice. Cryogen droplet size profiling for various cryogen delivery devices was estimated by optically imaging the droplets in flight. Heat removal for various cryogen delivery devices was estimated over a range of spraying distances by temperature measurements in an skin phantom used in conjunction with an inverse heat conduction model. A substantial range of mass outputs were measured for the cryogen delivery devices while heat removal varied by less than a factor of two. Droplet profiling demonstrated differences in droplet size and spray density. Results of this study show that variation in heat removal by different cryogen delivery devices is modest despite the relatively large difference in cryogen mass output and droplet size. A non-linear relationship between heat removal by various devices and droplet size and spray density was observed. Copyright 2001 Wiley-Liss, Inc.

  3. The impact of sample size on the reproducibility of voxel-based lesion-deficit mappings.

    PubMed

    Lorca-Puls, Diego L; Gajardo-Vidal, Andrea; White, Jitrachote; Seghier, Mohamed L; Leff, Alexander P; Green, David W; Crinion, Jenny T; Ludersdorfer, Philipp; Hope, Thomas M H; Bowman, Howard; Price, Cathy J

    2018-07-01

    This study investigated how sample size affects the reproducibility of findings from univariate voxel-based lesion-deficit analyses (e.g., voxel-based lesion-symptom mapping and voxel-based morphometry). Our effect of interest was the strength of the mapping between brain damage and speech articulation difficulties, as measured in terms of the proportion of variance explained. First, we identified a region of interest by searching on a voxel-by-voxel basis for brain areas where greater lesion load was associated with poorer speech articulation using a large sample of 360 right-handed English-speaking stroke survivors. We then randomly drew thousands of bootstrap samples from this data set that included either 30, 60, 90, 120, 180, or 360 patients. For each resample, we recorded effect size estimates and p values after conducting exactly the same lesion-deficit analysis within the previously identified region of interest and holding all procedures constant. The results show (1) how often small effect sizes in a heterogeneous population fail to be detected; (2) how effect size and its statistical significance varies with sample size; (3) how low-powered studies (due to small sample sizes) can greatly over-estimate as well as under-estimate effect sizes; and (4) how large sample sizes (N ≥ 90) can yield highly significant p values even when effect sizes are so small that they become trivial in practical terms. The implications of these findings for interpreting the results from univariate voxel-based lesion-deficit analyses are discussed. Copyright © 2018 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  4. Thermal conductivity measurements of particulate materials under Martian conditions

    NASA Technical Reports Server (NTRS)

    Presley, M. A.; Christensen, P. R.

    1993-01-01

    The mean particle diameter of surficial units on Mars has been approximated by applying thermal inertia determinations from the Mariner 9 Infrared Radiometer and the Viking Infrared Thermal Mapper data together with thermal conductivity measurement. Several studies have used this approximation to characterize surficial units and infer their nature and possible origin. Such interpretations are possible because previous measurements of the thermal conductivity of particulate materials have shown that particle size significantly affects thermal conductivity under martian atmospheric pressures. The transfer of thermal energy due to collisions of gas molecules is the predominant mechanism of thermal conductivity in porous systems for gas pressures above about 0.01 torr. At martian atmospheric pressures the mean free path of the gas molecules becomes greater than the effective distance over which conduction takes place between the particles. Gas particles are then more likely to collide with the solid particles than they are with each other. The average heat transfer distance between particles, which is related to particle size, shape and packing, thus determines how fast heat will flow through a particulate material.The derived one-to-one correspondence of thermal inertia to mean particle diameter implies a certain homogeneity in the materials analyzed. Yet the samples used were often characterized by fairly wide ranges of particle sizes with little information about the possible distribution of sizes within those ranges. Interpretation of thermal inertia data is further limited by the lack of data on other effects on the interparticle spacing relative to particle size, such as particle shape, bimodal or polymodal mixtures of grain sizes and formation of salt cements between grains. To address these limitations and to provide a more comprehensive set of thermal conductivities vs. particle size a linear heat source apparatus, similar to that of Cremers, was assembled to provide a means of measuring the thermal conductivity of particulate samples. In order to concentrate on the dependence of the thermal conductivity on particle size, initial runs will use spherical glass beads that are precision sieved into relatively small size ranges and thoroughly washed.

  5. Size and surface effects on the magnetism of magnetite and maghemite nanoparticles

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nikiforov, V. N., E-mail: pppnvn@yandex.ru; Ignatenko, A. N.; Irkhin, V. Yu.

    2017-02-15

    The size effects of magnetite and maghemite nanoparticles on their magnetic properties (magnetic moment, Curie temperature, blocking temperature, etc.) have been investigated. Magnetic separation and centrifugation of an aqueous solution of nanoparticles were used for their separation into fractions; their sizes were measured by atomic force microscopy, dynamic light scattering, and electron microscopy. A change in the size leads to a change in the Curie temperature and magnetic moment per formula unit. Both native nanoparticles and those covered with a bioresorbable layer have been considered. The magnetic properties have been calculated by the Monte Carlo method for the classical Heisenbergmore » model with various bulk and surface magnetic moments.« less

  6. Balance exercise for persons with multiple sclerosis using Wii games: a randomised, controlled multi-centre study.

    PubMed

    Nilsagård, Ylva E; Forsberg, Anette S; von Koch, Lena

    2013-02-01

    The use of interactive video games is expanding within rehabilitation. The evidence base is, however, limited. Our aim was to evaluate the effects of a Nintendo Wii Fit® balance exercise programme on balance function and walking ability in people with multiple sclerosis (MS). A multi-centre, randomised, controlled single-blinded trial with random allocation to exercise or no exercise. The exercise group participated in a programme of 12 supervised 30-min sessions of balance exercises using Wii games, twice a week for 6-7 weeks. Primary outcome was the Timed Up and Go test (TUG). In total, 84 participants were enrolled; four were lost to follow-up. After the intervention, there were no statistically significant differences between groups but effect sizes for the TUG, TUGcognitive and, the Dynamic Gait Index (DGI) were moderate and small for all other measures. Statistically significant improvements within the exercise group were present for all measures (large to moderate effect sizes) except in walking speed and balance confidence. The non-exercise group showed statistically significant improvements for the Four Square Step Test and the DGI. In comparison with no intervention, a programme of supervised balance exercise using Nintendo Wii Fit® did not render statistically significant differences, but presented moderate effect sizes for several measures of balance performance.

  7. The influence of prefire tree growth and crown condition on postfire mortality of sugar pine following prescribed fire in Sequoia National Park

    USGS Publications Warehouse

    Nesmith, Jonathan C. B.; Das, Adrian J.; O'Hara, Kevin L.; van Mantgem, Phillip J.

    2015-01-01

    Tree mortality is a vital component of forest management in the context of prescribed fires; however, few studies have examined the effect of prefire tree health on postfire mortality. This is especially relevant for sugar pine (Pinus lambertiana Douglas), a species experiencing population declines due to a suite of anthropogenic factors. Using data from an old-growth mixed-conifer forest in Sequoia National Park, we evaluated the effects of fire, tree size, prefire radial growth, and crown condition on postfire mortality. Models based only on tree size and measures of fire damage were compared with models that included tree size, fire damage, and prefire tree health (e.g., measures of prefire tree radial growth or crown condition). Immediately following the fire, the inclusion of different metrics of prefire tree health produced variable improvements over the models that included only tree size and measures of fire damage, as models that included measures of crown condition performed better than fire-only models, but models that included measures of prefire radial growth did not perform better. However, 5 years following the fire, sugar pine mortality was best predicted by models that included measures of both fire damage and prefire tree health, specifically, diameter at breast height (DBH, 1.37 m), crown scorch, 30-year mean growth, and the number of sharp declines in growth over a 30-year period. This suggests that factors that influence prefire tree health (e.g., drought, competition, pathogens, etc.) may partially determine postfire mortality, especially when accounting for delayed mortality following fire.

  8. How self-reported hot flashes may relate to affect, cognitive performance and sleep.

    PubMed

    Regestein, Quentin; Friebely, Joan; Schiff, Isaac

    2015-08-01

    To explain the controversy about whether midlife women who self-report hot flashes have relatively increased affective symptoms, poor cognitive performance or worse sleep. Retrospective data from 88 women seeking relief from bothersome day and night hot flashes were submitted to mixed linear regression modeling to find if estimated hot flashes, as measured by Women's Health Questionnaire (WHQ) items, or diary-documented hot flashes recorded daily, were associated with each other, or with affective, cognitive or sleep measures. Subjects averaged 6.3 daytime diary-documented hot flashes and 2.4 nighttime diary-documented hot flashes per 24h. Confounder-controlled diary-documented hot flashes but not estimated hot flashes were associated with increased Leeds anxiety scores (F=4.9; t=2.8; p=0.01) and Leeds depression scores (3.4; 2.5; 0.02), decreased Stroop Color-Word test performance (9.4; 3.5; 0.001), increased subjective sleep disturbance (effect size=0.83) and increased objective sleep disturbance (effect size=0.35). Hot flash effects were small to moderate in size. Univariate but not multivariate analyses revealed that all hot flash measures were associated with all affect measures. Different measures of hot flashes associated differently with affect, cognition and sleep. Only nighttime diary-document hot flash consistently correlated with any affect measures in multivariate analyses. The use of differing measures for hot flashes, affect, cognition and sleep may account for the continually reported inconsistencies in menopause study outcomes. This problem impedes forging a consensus on whether hot flashes correlate with neuropsychological symptoms. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Effect of exercise training on walking mobility in multiple sclerosis: a meta-analysis.

    PubMed

    Snook, Erin M; Motl, Robert W

    2009-02-01

    The study used meta-analytic procedures to examine the overall effect of exercise training interventions on walking mobility among individuals with multiple sclerosis. A search was conducted for published exercise training studies from 1960 to November 2007 using MEDLINE, PsychINFO, CINAHL, and Current Contents Plus. Studies were selected if they measured walking mobility, using instruments identified as acceptable walking mobility constructs and outcome measures for individuals with neurologic disorders, before and after an intervention that included exercise training. Forty-two published articles were located and reviewed, and 22 provided enough data to compute effect sizes expressed as Cohen's d. Sixty-six effect sizes were retrieved from the 22 publications with 600 multiple sclerosis participants and yielded a weighted mean effect size of g = 0.19 (95% confidence interval, 0.09-0.28). There were larger effects associated with supervised exercise training ( g = 0.32), exercise programs that were less than 3 months in duration (g = 0.28), and mixed samples of relapsing-remitting and progressive multiple sclerosis (g = 0.52). The cumulative evidence supports that exercise training is associated with a small improvement in walking mobility among individuals with multiple sclerosis.

  10. The acute and post-discontinuation effects of a glucocorticoid receptor (GR) antagonist probe on sleep and the HPA axis in chronic insomnia: a pilot study.

    PubMed

    Buckley, Theresa; Duggal, Vandana; Schatzberg, Alan F

    2008-06-15

    Hypothalamic-pituitary-adrenal axis (HPA) hyperactivity has been reported in patients with chronic insomnia without depression. Aglucocorticoid receptor (GR) antagonist may re-regulate HPA axis activity even after discontinuation and may have clinical benefit. Ten subjects with chronic insomnia participated in a placebo controlled double-blinded prospective 30-day pilot study of the acute and post-discontinuation effects of a 5-day course of 600 mg of the glucocorticoid antagonist, mifepristone. Sleep outcome measures were polysomnogram and Insomnia Severity Index. Hormonal outcome measures were mean overnight cortisol and ACTH (23:00-07:00). We predicted sleep would improve and that overnight cortisol and ACTH would decrease at 2 weeks post-treatment discontinuation. At 2 weeks post-discontinuation, Insomnia Severity Index (ISI) decreased by 4.0 points (effect size = 0.97). Polysomnogram findings were limited. Mean cortisol (0.84 microg/dL, effect size = 0.91) and ACTH (5.50 pg/mL, effect size = 0.96) were still mildly increased (23:00 to 07:00). Post hoc analysis revealed that, the ratio of cortisol/ ACTH decreased (-0.21, effect size = 1.15) as did mean cortisol from 18:00 to 23:00 (-0.47 microg/dL, effect size = 0.56). This is the first study of a GR antagonist in chronic insomnia. Sleep improvement manifests in terms of decreased ISI post-treatment discontinuation. The decrease in cortisol in the early evening (18:00 to 23:00) in combination with the decrease in cortisol/ ACTH ratio may be an indicator of the longer-term biological mode of action of the drug.

  11. Decending motion of particle and its effect on ozone hole chemistry

    NASA Technical Reports Server (NTRS)

    Iwasaka, Y.

    1988-01-01

    Particle descending motion is one possible process which causes ozone loss near the tropopause in the Antarctic spring. However, this particle size distribution has not yet been measured. Particle settling is an important redistribution process of the chemical constituents contained in the particles. To understand particle settling effects on the Ozone Hole, information on the size distribution and the chemical composition of the particles is necessary.

  12. [Effectiveness of eyeglasses for protection against ultraviolet rays].

    PubMed

    Sakamoto, Y; Kojima, M; Sasaki, K

    1999-05-01

    The relationship between eyeglass size and protection of the eye surface from the effects of solar ultraviolet (UV) rays was investigated. Solar UV rays irradiating the eye surface were measured on a mannequin which modeled the standard facial bone structure of a Japanese female. UV sensor chips (photo-sensitivity: 260-400 nm) were attached to the ocular surface of the lid fissure. UV measurement was done from 12:00 to 15:00 on a sunny day in March. UV intensity was measured under the following conditions: 1) with or without eyeglasses, 2) wearing sunglasses with side protectors, and 3) wearing a cap with a 7 cm brim. Eyeglasses of four frame sizes (width: 48-57 mm) were put on the mannequin. All lenses were made of plastic and coated so as to be impervious to rays shorter than 400 nm. The refractive power was 0 diopters. At the same time, UV irradiation intensity from all directions (excluding from the earth direction) was measured using a polyhedron type UV sensor with 25 sensor chips. Except for eyeglasses with the smallest frame size, eyeglasses effectively reduced UV exposure to sunlight from the upper front direction. However, protection against rays from the upper temporal direction was extremely poor. Sunlight from the upper back was reflected by the posterior surface of the eyeglasses and reached the eye surface. The efficacy of eyeglasses against UV depends on their size. The shape of the eyeglasses and reflection from the posterior lens surface are also of great importance. Small eyeglasses do not offer ideal UV protection for the Japanese face shape.

  13. Effect of pectin methylesterase on carrot (Daucus carota) juice cloud stability.

    PubMed

    Schultz, Alison K; Anthon, Gordon E; Dungan, Stephanie R; Barrett, Diane M

    2014-02-05

    To determine the effect of residual enzyme activity on carrot juice cloud, 0 to 1 U/g pectin methylesterase (PME) was added to pasteurized carrot juice. Cloud stability and particle diameters were measured to quantify juice cloud stability and clarification for 56 days of storage. All levels of PME addition resulted in clarification; higher amounts had a modest effect in causing more rapid clarification, due to a faster increase in particle size. The cloud initially exhibited a trimodal distribution of particle sizes. For enzyme-containing samples, particles in the smallest-sized mode initially aggregated to merge with the second peak over 5-10 days. This larger population then continued to aggregate more slowly over longer times. This observation of a more rapid destabilization process initially, followed by slower subsequent changes in the cloud, was also manifested in measurements of sedimentation extent and in turbidity tests. Optical microscopy showed that aggregation created elongated, fractal particle structures over time.

  14. The relationship between ADHD symptoms, mood instability, and self-reported offending.

    PubMed

    Gudjonsson, Gisli H; Sigurdsson, Jon Fridrik; Adalsteinsson, Tomas F; Young, Susan

    2013-05-01

    To investigate the relative importance of ADHD symptoms, mood instability, and antisocial personality disorder traits in predicting self-reported offending. A total of 295 Icelandic students completed two scales of offending behavior and measures of ADHD symptoms, mood instability, and antisocial personality traits. Self-reported offending from the two independent scales correlated significantly with ADHD symptoms, mood instability, and antisocial personality traits with medium to large effect size. Multiple regressions showed that ADHD symptoms contributed to the two outcome measures beyond that of age and gender with a medium effect size. The ADHD effects were only partly mediated by mood instability and antisocial personality traits for general offending but were almost completely mediated by the more reactive measure of antisocial behavior. ADHD appears to be a potential risk factor for general offending in its own right irrespective of the presence of comorbidity, whereas mood instability is more important with regard to reactive behavior.

  15. Erosive burning research. [for solid-propellant rocket engines

    NASA Technical Reports Server (NTRS)

    Strand, L.; Yang, L. C.; Nguyen, M. H.; Cohen, N. S.

    1986-01-01

    A status report is given on the results for the completed tests in a series of motor firings being carried out to measure the effects of the parameters that are considered to most strongly influence the scaling to larger rocket motor sizes of the transition to/or threshold conditions for erosive burning rate augmentation. Propellant burning rates at locations along the axis of the test motors are measured with a newly developed plasma capacitance gauge technique. The measured results are compared with erosive-burning predictions from a supporting ballistics analysis. The completed motor firings have successfully demonstrated response to the designed test variables. The trends with varying propellant burning rate, chamber pressure, and mass flow rate are consistent with existing results, but no pronounced effect of surface roughness has been observed. Rather, the influence of propellant oxidizer particle size on erosive burning is through its effect on the base, no-corssflow burning rate.

  16. Ecstasy (MDMA) and memory function: a meta-analytic update.

    PubMed

    Laws, Keith R; Kokkalis, Joy

    2007-08-01

    A meta-analysis was conducted to examine the impact of recreational ecstasy use on short-term memory (STM), long-term memory (LTM), verbal and visual memory. We located 26 studies containing memory data for ecstasy and non-ecstasy users from which effect sizes could be derived. The analyses provided measures of STM and LTM in 610 and 439 ecstasy users and revealed moderate-to-large effect sizes (Cohen's d) of d = -0.63 and d = -0.87, respectively. The difference between STM versus LTM was non-significant. The effect size for verbal memory was large (d = -1.00) and significantly larger than the small effect size for visual memory (d = -0.27). Indeed, our analyses indicate that visual memory may be affected more by concurrent cannabis use. Finally, we found that the total lifetime number of ecstasy tablets consumed did not significantly predict memory performance. Copyright 2007 John Wiley & Sons, Ltd.

  17. Optical technique to study the impact of heavy rain on aircraft performance

    NASA Technical Reports Server (NTRS)

    Hess, C. F.; Li, F.

    1985-01-01

    A laser based technique was investigated and shown to have the potential to obtain measurements of the size and velocity of water droplets used in a wind tunnel to simulate rain. A theoretical model was developed which included some simple effects due to droplet nonsphericity. Parametric studies included the variation of collection distance (up to 4 m), angle of collection, effect of beam interference by the spray, and droplet shape. Accurate measurements were obtained under extremely high liquid water content and spray interference. The technique finds applications in the characterization of two phase flows where the size and velocity of particles are needed.

  18. Effects of size on three-cone bit performance in laboratory drilled shale

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Black, A.D.; DiBona, B.G.; Sandstrom, J.L.

    1982-09-01

    The effects of size on the performance of 3-cone bits were measured during laboratory drilling tests in shale at simulated downhole conditions. Four Reed HP-SM 3-cone bits with diameters of 6 1/2, 7 7/8, 9 1/2 and 11 inches were used to drill Mancos shale with water-based mud. The tests were conducted at constant borehole pressure, two conditions of hydraulic horsepower per square inch of bit area, three conditions of rotary speed and four conditions of weight-on-bit per inch of bit diameter. The resulting penetration rates and torques were measured. Statistical techniques were used to analyze the data.

  19. Magnetocapacitance effect in core/shell NiO nanoparticles

    NASA Astrophysics Data System (ADS)

    Roy, Subir; Kambhala, Nagaiah; Angappane, S.

    2018-04-01

    The exchange bias and magnetocapacitance properties of nickel oxide nanoparticles of average particle size 50 nm have been studied. NiO nanoparticles of uniform size distribution were synthesized by a sol-gel method using nickel acetate and polyvinyl acetate. The magnetic measurements show the ferromagnetic like behavior exhibiting exchange bias effect indicative of the formation of core/shell structure of NiO with a antiferromagnetic core and ferromagnetic shell. An electrical double layer capacitance behavior was observed for NiO nanoparticles in the cyclic voltammetry measurement, and it was found that the value of capacitance decreased by about 26 % under the application of magnetic field of 0.1 T.

  20. Influence of fuel temperature on atomization performance of pressure-swirl atomizers

    NASA Astrophysics Data System (ADS)

    Wang, X. F.; Lefebvre, A. H.

    The influence of fuel temperature on mean drop size and drop-size distribution is examined for aviation gasoline and diesel oil, using three pressure-swirl simplex nozzles. Spray characteristics are measured over wide ranges of fuel injection pressure and ambient air pressure using a Malvern spray analyzer. Fuel temperatures are varied from -20 C to +50 C. Over this range of temperature, the overall effect of an increase in fuel temperature is to reduce the mean drop size and broaden the distribution of drop sizes in the spray. Generally, it is found that the influence of fuel temperature on mean drop size is far more pronounced for diesel oil than for gasoline. For both fuels the beneficial effect of higher fuel temperatures on atomization quality is sensibly independent of ambient air pressure.

  1. Cognitive Remediation and Emotion Skills Training (CREST) for anorexia nervosa in individual format: self-reported outcomes.

    PubMed

    Tchanturia, Kate; Doris, Eli; Mountford, Vicki; Fleming, Caroline

    2015-03-20

    To evaluate self-reported outcomes after a brief course of skills-based individual therapy for inpatients with anorexia nervosa (AN). In this case series study 37 adults with AN participated in cognitive remediation and emotion skills training (CREST) sessions, and completed social anhedonia, alexithymia and motivational measures before and after the intervention. The CREST primary outcome measures were total scores on the Revised Social Anhedonia Scale (RSAS), which decreased significantly (p = 0.03) with an effect size of 0.31, and the Toronto Alexithymia Scale (TAS), which also decreased significantly (p = 0.05) with an effect size of 0.35. The secondary outcome measures focused on motivation: perceived 'importance to change' and 'ability to change'; the second of which increased significantly (p < 0.001) with a medium effect size (d = 0.71). The individual format of CREST led to a decrease in patients' self-reported social anhedonia, an improvement in the ability to label their emotions, and increased confidence in their ability to change. Considering the limited number of individual sessions, this is a promising preliminary finding which warrants further research.

  2. Effect of smoking parameters on the particle size distribution and predicted airway deposition of mainstream cigarette smoke.

    PubMed

    Kane, David B; Asgharian, Bahman; Price, Owen T; Rostami, Ali; Oldham, Michael J

    2010-02-01

    It is known that puffing conditions such as puff volume, duration, and frequency vary substantially among individual smokers. This study investigates how these parameters affect the particle size distribution and concentration of fresh mainstream cigarette smoke (MCS) and how these changes affect the predicted deposition of MCS particles in a model human respiratory tract. Measurements of the particle size distribution made with an electrical low pressure impactor for a variety of puffing conditions are presented. The average flow rate of the puff is found to be the major factor effecting the measured particle size distribution of the MCS. The results of these measurements were then used as input to a deterministic dosimetry model (MPPD) to estimate the changes in the respiratory tract deposition fraction of smoke particles. The MPPD dosimetry model was modified by incorporating mechanisms involved in respiratory tract deposition of MCS: hygroscopic growth, coagulation, evaporation of semivolatiles, and mixing of the smoke with inhaled dilution air. The addition of these mechanisms to MPPD resulted in reasonable agreement between predicted airway deposition and human smoke retention measurements. The modified MPPD model predicts a modest 10% drop in the total deposition efficiency in a model human respiratory tract as the puff flow rate is increased from 1050 to 3100 ml/min, for a 2-s puff.

  3. Particle size analysis in a turbid media with a single-fiber, optical probe while using a visible spectrometer

    DOEpatents

    Canpolat, Murat; Mourant, Judith R.

    2003-12-09

    Apparatus and method for measuring scatterer size in a dense media with only a single fiber for both light delivery and collection are disclosed. White light is used as a source and oscillations of the detected light intensities are measured as a function of wavelength. The maximum and minimum of the oscillations can be used to determine scatterer size for monodisperse distributions of spheres when the refractive indices are known. In addition several properties of the probe relevant to tissue diagnosis are disclosed including the effects of absorption, a broad distribution of scatterers, and the depth probed.

  4. Psychophysical and perceptual performance in a simulated-scotoma model of human eye injury

    NASA Astrophysics Data System (ADS)

    Brandeis, R.; Egoz, I.; Peri, D.; Sapiens, N.; Turetz, J.

    2008-02-01

    Macular scotomas, affecting visual functioning, characterize many eye and neurological diseases like AMD, diabetes mellitus, multiple sclerosis, and macular hole. In this work, foveal visual field defects were modeled, and their effects were evaluated on spatial contrast sensitivity and a task of stimulus detection and aiming. The modeled occluding scotomas, of different size, were superimposed on the stimuli presented on the computer display, and were stabilized on the retina using a mono Purkinje Eye-Tracker. Spatial contrast sensitivity was evaluated using square-wave grating stimuli, whose contrast thresholds were measured using the method of constant stimuli with "catch trials". The detection task consisted of a triple conjunctive visual search display of: size (in visual angle), contrast and background (simple, low-level features vs. complex, high-level features). Search/aiming accuracy as well as R.T. measures used for performance evaluation. Artificially generated scotomas suppressed spatial contrast sensitivity in a size dependent manner, similar to previous studies. Deprivation effect was dependent on spatial frequency, consistent with retinal inhomogeneity models. Stimulus detection time was slowed in complex background search situation more than in simple background. Detection speed was dependent on scotoma size and size of stimulus. In contrast, visually guided aiming was more sensitive to scotoma effect in simple background search situation than in complex background. Both stimulus aiming R.T. and accuracy (precision targeting) were impaired, as a function of scotoma size and size of stimulus. The data can be explained by models distinguishing between saliency-based, parallel and serial search processes, guiding visual attention, which are supported by underlying retinal as well as neural mechanisms.

  5. Corpus Callosum Anatomy in Chronically Treated and Stimulant Naive ADHD

    ERIC Educational Resources Information Center

    Schnoebelen, Sarah; Semrud-Clikeman, Margaret; Pliszka, Steven R.

    2010-01-01

    Objective: To determine the effect of chronic stimulant treatment on corpus callosum (CC) size in children with ADHD using volumetric and area measurements. Previously published research indicated possible medication effects on specific areas of the CC. Method: Measurements of the CC from anatomical MRIs were obtained from children aged 9-16 in…

  6. Effects of visual expertise on a novel eye-size illusion: Implications for holistic face processing

    PubMed Central

    Fu, Genyue; Dong, Yan; Quinn, Paul C.; Xiao, Wen S.; Wang, Qiandong; Chen, Guowei; Pascalis, Olivier; Lee, Kang

    2015-01-01

    The present study examined the effect of visual experience on the magnitude of a novel eye-size illusion: when the size of a face’s frame is increased or decreased but eye size is unchanged, observers judge the size of the eyes to be different from that in the original face frame. In the current study, we asked Chinese and Caucasian participants to judge eye size in different pairs of faces and measured the magnitude of the illusion when the faces were own- or other-age (adult vs. infant faces) and when the faces were own- or other-race (Chinese vs. Caucasian faces). We found an other-age effect and an other-race effect with the eye-size illusion: The illusion was more pronounced with own-race and own-age faces than with other-race and other-age faces. These findings taken together suggest that visual experience with faces influences the magnitude of this novel illusion. Extensive experience with certain face categories strengthens the illusion in the context of these categories, but lack of it reduces the magnitude of the illusion. Our results further imply that holistic processing may play an important role in engendering the eye-size illusion. PMID:26048685

  7. Effects of set-size and lateral masking in visual search.

    PubMed

    Põder, Endel

    2004-01-01

    In the present research, the roles of lateral masking and central processing limitations in visual search were studied. Two search conditions were used: (1) target differed from distractors by presence/absence of a simple feature; (2) target differed by relative position of the same components only. The number of displayed stimuli (set-size) and the distance between neighbouring stimuli were varied as independently as possible in order to measure the effect of both. The effect of distance between stimuli (lateral masking) was found to be similar in both conditions. The effect of set-size was much larger for relative position stimuli. The results support the view that perception of relative position of stimulus components is limited mainly by the capacity of central processing.

  8. Portion size and intended consumption. Evidence for a pre-consumption portion size effect in males?

    PubMed

    Robinson, Eric; te Raa, Wesselien; Hardman, Charlotte A

    2015-08-01

    Larger portions increase energy intake (the 'portion size effect'); however, the mechanisms behind this effect are unclear. Although pre-meal intentions are thought to be an important determinant of energy intake, little research has examined how much of a meal individuals intend to eat when served standard versus larger portion sizes. Three studies examined the effect of manipulating portion size on intended food consumption. In Studies 1 (spaghetti bolognese) and 2 (curry and rice) male participants were shown an image of either a standard or a larger meal and indicated how much of the meal they intended to consume. In Study 3 male and female participants were served either a standard or a larger portion of ice cream for dessert, they indicated how much they intended to consume and then ate as much of the ice cream as they desired. Regardless of being shown standard or large portion sizes, in Studies 1 and 2 participants reported that they intended to eat the majority of the meal, equating to a large difference in intended energy consumption between portion size conditions (a 'pre-consumption portion size effect'). This finding was replicated in male participants in Study 3, although females intended to eat a smaller proportion of the larger portion of ice cream, compared to the standard portion. Both male and female participants tended to eat in accordance with their pre-meal intentions and a portion size effect on actual consumption was subsequently observed in males, but not in females. The portion size effect may be observed when measuring pre-meal intended consumption in males. Copyright © 2015. Published by Elsevier Ltd.

  9. Electrophysiological evidence for size invariance in masked picture repetition priming

    PubMed Central

    Eddy, Marianna D.; Holcomb, Phillip J.

    2009-01-01

    This experiment examined invariance in object representations through measuring event-related potentials (ERPs) to pictures in a masked repetition priming paradigm. Pairs of pictures were presented where the prime was either the same size or half the size of the target object and the target was either presented in a normal orientation or was a normal sized mirror reflection of the prime object. Previous masked repetition priming studies have found a cascade of priming effect sensitive to perceptual (N190/P190) and semantic (N400) properties of the stimulus. This experiment found that both early (N190/P190 effects) and later effects (N400) were invariant to size, whereas only the N190/P190 effect was invariant to mirror reflection. The combination of a small prime and a mirror reflected target led to no significant priming effects. Taken together, the results of this set of experiments suggests that object recognition, more specifically, activating an object representation, occurs in a hierarchical fashion where overlapping perceptual information between the prime and target is necessary, although not always sufficient, to activate a higher level semantic representation. PMID:19560248

  10. The effect of finite field size on classification and atmospheric correction

    NASA Technical Reports Server (NTRS)

    Kaufman, Y. J.; Fraser, R. S.

    1981-01-01

    The atmospheric effect on the upward radiance of sunlight scattered from the Earth-atmosphere system is strongly influenced by the contrasts between fields and their sizes. For a given atmospheric turbidity, the atmospheric effect on classification of surface features is much stronger for nonuniform surfaces than for uniform surfaces. Therefore, the classification accuracy of agricultural fields and urban areas is dependent not only on the optical characteristics of the atmosphere, but also on the size of the surface do not account for the nonuniformity of the surface have only a slight effect on the classification accuracy; in other cases the classification accuracy descreases. The radiances above finite fields were computed to simulate radiances measured by a satellite. A simulation case including 11 agricultural fields and four natural fields (water, soil, savanah, and forest) was used to test the effect of the size of the background reflectance and the optical thickness of the atmosphere on classification accuracy. It is concluded that new atmospheric correction methods, which take into account the finite size of the fields, have to be developed to improve significantly the classification accuracy.

  11. Investigation of multiple scattering effects in aerosols

    NASA Technical Reports Server (NTRS)

    Deepak, A.

    1980-01-01

    The results are presented of investigations on the various aspects of multiple scattering effects on visible and infrared laser beams transversing dense fog oil aerosols contained in a chamber (4' x 4' x 9'). The report briefly describes: (1) the experimental details and measurements; (2) analytical representation of the aerosol size distribution data by two analytical models (the regularized power law distribution and the inverse modified gamma distribution); (3) retrieval of aerosol size distributions from multispectral optical depth measurements by two methods (the two and three parameter fast table search methods and the nonlinear least squares method); (4) modeling of the effects of aerosol microphysical (coagulation and evaporation) and dynamical processes (gravitational settling) on the temporal behavior of aerosol size distribution, and hence on the extinction of four laser beams with wavelengths 0.44, 0.6328, 1.15, and 3.39 micrometers; and (5) the exact and approximate formulations for four methods for computing the effects of multiple scattering on the transmittance of laser beams in dense aerosols, all of which are based on the solution of the radiative transfer equation under the small angle approximation.

  12. Self-objectification and disordered eating: A meta-analysis.

    PubMed

    Schaefer, Lauren M; Thompson, J Kevin

    2018-06-01

    Objectification theory posits that self-objectification increases risk for disordered eating. The current study sought to examine the relationship between self-objectification and disordered eating using meta-analytic techniques. Data from 53 cross-sectional studies (73 effect sizes) revealed a significant moderate positive overall effect (r = .39), which was moderated by gender, ethnicity, sexual orientation, and measurement of self-objectification. Specifically, larger effect sizes were associated with female samples and the Objectified Body Consciousness Scale. Effect sizes were smaller among heterosexual men and African American samples. Age, body mass index, country of origin, measurement of disordered eating, sample type and publication type were not significant moderators. Overall, results from the first meta-analysis to examine the relationship between self-objectification and disordered eating provide support for one of the major tenets of objectification theory and suggest that self-objectification may be a meaningful target in eating disorder interventions, though further work is needed to establish temporal and causal relationships. Findings highlight current gaps in the literature (e.g., limited representation of males, and ethnic and sexual minorities) with implications for guiding future research. © 2018 Wiley Periodicals, Inc.

  13. Investigation of multiple scattering effects in aerosols

    NASA Astrophysics Data System (ADS)

    Deepak, A.

    1980-05-01

    The results are presented of investigations on the various aspects of multiple scattering effects on visible and infrared laser beams transversing dense fog oil aerosols contained in a chamber (4' x 4' x 9'). The report briefly describes: (1) the experimental details and measurements; (2) analytical representation of the aerosol size distribution data by two analytical models (the regularized power law distribution and the inverse modified gamma distribution); (3) retrieval of aerosol size distributions from multispectral optical depth measurements by two methods (the two and three parameter fast table search methods and the nonlinear least squares method); (4) modeling of the effects of aerosol microphysical (coagulation and evaporation) and dynamical processes (gravitational settling) on the temporal behavior of aerosol size distribution, and hence on the extinction of four laser beams with wavelengths 0.44, 0.6328, 1.15, and 3.39 micrometers; and (5) the exact and approximate formulations for four methods for computing the effects of multiple scattering on the transmittance of laser beams in dense aerosols, all of which are based on the solution of the radiative transfer equation under the small angle approximation.

  14. The Effects of Sex and Size on Status Ranking.

    ERIC Educational Resources Information Center

    Crosbie, Paul V.

    1979-01-01

    Sex, body size, several sociocultural variables, and status rank were measured in mixed-sex small groups. The intervening sociocultural variables explained some but not all of the interrelationships. Results underscore the empirical vulnerability of social-psychological explanations of sex-role behavior and signal the need for further research.…

  15. Effects of lint cleaning on lint trash particle size distribution

    USDA-ARS?s Scientific Manuscript database

    Cotton quality trash measurements used today typically yield a single value for trash parameters for a lint sample (i.e. High Volume Instrument – percent area; Advanced Fiber Information System – total count, trash size, dust count, trash count, and visible foreign matter). A Cotton Trash Identifica...

  16. TOTAL RESPIRATORY TRACT DEPOSITION OF FINE MICRON-SIZED PARTICLES IN HEALTHY ADULTS: EMPIRICIAL EQUATIONS FOR GENDER AND BREATHING PATTERN

    EPA Science Inventory

    An accurate dose estimation under various inhalation conditions is important for assessing both the potential health effects of pollutant particles and the therapeutic efficacy of medical aerosols. We measured total deposition fraction (TDF) of monodisperse micron-sized particles...

  17. Guiding of Plasmons and Phonons in Complex Three Dimensional Structures

    DTIC Science & Technology

    2013-01-01

    typical sample. We employed X - ray diffraction (XRD) to measure the average grain size across the entire depth of the sample over spot sizes Figure...propagation distance L as the 1/e decay length of the field intensity along x ...as well as the network layout with subwavelegth gap size and internode distance on the order of the effective wavelength, a small 2 x 2 resonant

  18. Depictive and metric body size estimation in anorexia nervosa and bulimia nervosa: A systematic review and meta-analysis.

    PubMed

    Mölbert, Simone Claire; Klein, Lukas; Thaler, Anne; Mohler, Betty J; Brozzo, Chiara; Martus, Peter; Karnath, Hans-Otto; Zipfel, Stephan; Giel, Katrin Elisabeth

    2017-11-01

    A distorted representation of one's own body is a diagnostic criterion and core psychopathology of both anorexia nervosa (AN) and bulimia nervosa (BN). Despite recent technical advances in research, it is still unknown whether this body image disturbance is characterized by body dissatisfaction and a low ideal weight and/or includes a distorted perception or processing of body size. In this article, we provide an update and meta-analysis of 42 articles summarizing measures and results for body size estimation (BSE) from 926 individuals with AN, 536 individuals with BN and 1920 controls. We replicate findings that individuals with AN and BN overestimate their body size as compared to controls (ES=0.63). Our meta-regression shows that metric methods (BSE by direct or indirect spatial measures) yield larger effect sizes than depictive methods (BSE by evaluating distorted pictures), and that effect sizes are larger for patients with BN than for patients with AN. To interpret these results, we suggest a revised theoretical framework for BSE that accounts for differences between depictive and metric BSE methods regarding the underlying body representations (conceptual vs. perceptual, implicit vs. explicit). We also discuss clinical implications and argue for the importance of multimethod approaches to investigate body image disturbance. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. The characteristics and mechanisms of Au nanoparticles processed by functional centrifugal procedures

    NASA Astrophysics Data System (ADS)

    Shiau, Bo-Wen; Lin, Chien-Hung; Liao, Ying-Yen; Lee, Ya-Rong; Liu, Shih-Hao; Ding, Wei-Cheng; Lee, Jia-Ren

    2018-05-01

    In this work, the optical properties of Au nanoparticles processed by centrifugation techniques are studied. Most of the literature related to the control of nanoparticle size has focused on different preparation parameters; however, the wide size distribution is commonly an issue for follow-up investigations and further applications. Therefore, we developed a method in which specific-diameter particles can be effectively separated using different centrifugal procedures. The initial nanoparticle solution with a primary absorption peak at 534 nm is separated into discernible resonance wavelengths from 526 to 537 nm, with corresponding particle sizes from 30 to 55 nm. For the atomic force microscopy analysis of nanoparticle size, a dry cetyltrimethylammonium bromide (CTAB) film often covers the particles and interferes with the measurement; thus, CTAB has to be removed. However, if too much CTAB is removed, the surface of the Au nanoparticle becomes unstable, and the particles aggregate. Accordingly, we used UV spectroscopy to monitor the CTAB content; properly adjust the rotational speed and the number of centrifugation stages; and design a method that can effectively remove impurities, avoid clustering, and enable particle size measurement. The usually complicated procedures and high cost of preparation of specific-size Au nanoparticles are greatly simplified and reduced by the convenient extraction process proposed in this work, which would benefit related research and applications.

  20. [Gonad protective effect of radiation protective apron in chest radiography].

    PubMed

    Hashimoto, Masatoshi; Kato, Hideyuki; Fujibuchi, Toshiou; Ochi, Shigehiro; Morita, Fuminori

    2004-12-01

    Depending on the facility, a radiation protective apron (protector) is used to protect the gonad from radiation exposure in chest radiography. To determine the necessity of using a protector during chest radiography, we measured the effect of the protector on the gonad in this study. First, using a human body phantom, we measured the absorbed dose of the female gonad with and without the protector, using a thermoluminescence dosimeter (TLD), and confirmed its protective effect. Using the protector, the absorbed dose was reduced to 28+/-2% and 39+/-4% for field sizes of 14 x 17 inch and 14 x 14 inch, respectively. Next, we used Monte Carlo simulation and confirmed, not only the validity of the actual measurement values, but also the fact that the influence of radiation on the absorbed dose of the gonad was mostly from scattered radiation from inside the body for the 14 x 17 inch field size, and also from the X-ray tube for the 14 x 14 inch field size. Although a certain protective effect is achieved by using the protector, the radiation dose to the gonad is only a few microGy even without a protector. Thus, the risk of a genetic effect would be as small as 10(-8). Given that acceptable risk is below 10(-6), we conclude the use of a radiation protective apron is not necessary for diagnostic chest radiography.

  1. Steep delay discounting and addictive behavior: a meta-analysis of continuous associations.

    PubMed

    Amlung, Michael; Vedelago, Lana; Acker, John; Balodis, Iris; MacKillop, James

    2017-01-01

    To synthesize continuous associations between delayed reward discounting (DRD) and both addiction severity and quantity-frequency (QF); to examine moderators of these relationships; and to investigate publication bias. Meta-analysis of published studies examining continuous associations between DRD and addictive behaviors. Published, peer-reviewed studies on addictive behaviors (alcohol, tobacco, cannabis, stimulants, opiates and gambling) were identified via PubMed, MEDLINE and PsycInfo. Studies were restricted to DRD measures of monetary gains. Random-effects meta-analysis was conducted using Pearson's r as the effect size. Publication bias was evaluated using fail-safe N, Begg-Mazumdar and Egger's tests, meta-regression of publication year and effect size and imputation of missing studies. The primary meta-analysis revealed a small magnitude effect size that was highly significant (r = 0.14, P < 10 -14 ). Significantly larger effect sizes were observed for studies examining severity compared with QF (P = 0.01), but not between the type of addictive behavior (P = 0.30) or DRD assessment (P = 0.90). Indices of publication bias suggested a modest impact of unpublished findings. Delayed reward discounting is associated robustly with continuous measures of addiction severity and quantity-frequency. This relation is generally robust across type of addictive behavior and delayed reward discounting assessment modality. © 2016 Society for the Study of Addiction.

  2. Fast and precise dense grid size measurement method based on coaxial dual optical imaging system

    NASA Astrophysics Data System (ADS)

    Guo, Jiping; Peng, Xiang; Yu, Jiping; Hao, Jian; Diao, Yan; Song, Tao; Li, Ameng; Lu, Xiaowei

    2015-10-01

    Test sieves with dense grid structure are widely used in many fields, accurate gird size calibration is rather critical for success of grading analysis and test sieving. But traditional calibration methods suffer from the disadvantages of low measurement efficiency and shortage of sampling number of grids which could lead to quality judgment risk. Here, a fast and precise test sieve inspection method is presented. Firstly, a coaxial imaging system with low and high optical magnification probe is designed to capture the grid images of the test sieve. Then, a scaling ratio between low and high magnification probes can be obtained by the corresponding grids in captured images. With this, all grid dimensions in low magnification image can be obtained by measuring few corresponding grids in high magnification image with high accuracy. Finally, by scanning the stage of the tri-axis platform of the measuring apparatus, whole surface of the test sieve can be quickly inspected. Experiment results show that the proposed method can measure the test sieves with higher efficiency compare to traditional methods, which can measure 0.15 million grids (gird size 0.1mm) within only 60 seconds, and it can measure grid size range from 20μm to 5mm precisely. In a word, the presented method can calibrate the grid size of test sieve automatically with high efficiency and accuracy. By which, surface evaluation based on statistical method can be effectively implemented, and the quality judgment will be more reasonable.

  3. Structural characterization of casein micelles: shape changes during film formation.

    PubMed

    Gebhardt, R; Vendrely, C; Kulozik, U

    2011-11-09

    The objective of this study was to determine the effect of size-fractionation by centrifugation on the film structure of casein micelles. Fractionated casein micelles in solution were asymmetrically distributed with a small distribution width as measured by dynamic light scattering. Films prepared from the size-fractionated samples showed a smooth surface in optical microscopy images and a homogeneous microstructure in atomic force micrographs. The nano- and microstructure of casein films was probed by micro-beam grazing incidence small angle x-ray scattering (μGISAXS). Compared to the solution measurements, the sizes determined in the film were larger and broadly distributed. The measured GISAXS patterns clearly deviate from those simulated for a sphere and suggest a deformation of the casein micelles in the film. © 2011 IOP Publishing Ltd

  4. Effect of sulfate and carbonate minerals on particle-size distributions in arid soils

    USGS Publications Warehouse

    Goossens, Dirk; Buck, Brenda J.; Teng, Yuazxin; Robins, Colin; Goldstein, Harland L.

    2014-01-01

    Arid soils pose unique problems during measurement and interpretation of particle-size distributions (PSDs) because they often contain high concentrations of water-soluble salts. This study investigates the effects of sulfate and carbonate minerals on grain-size analysis by comparing analyses in water, in which the minerals dissolve, and isopropanol (IPA), in which they do not. The presence of gypsum, in particular, substantially affects particle-size analysis once the concentration of gypsum in the sample exceeds the mineral’s solubility threshold. For smaller concentrations particle-size results are unaffected. This is because at concentrations above the solubility threshold fine particles cement together or bind to coarser particles or aggregates already present in the sample, or soluble mineral coatings enlarge grains. Formation of discrete crystallites exacerbates the problem. When soluble minerals are dissolved the original, insoluble grains will become partly or entirely liberated. Thus, removing soluble minerals will result in an increase in measured fine particles. Distortion of particle-size analysis is larger for sulfate minerals than for carbonate minerals because of the much higher solubility in water of the former. When possible, arid soils should be analyzed using a liquid in which the mineral grains do not dissolve, such as IPA, because the results will more accurately reflect the PSD under most arid soil field conditions. This is especially important when interpreting soil and environmental processes affected by particle size.

  5. Social enhancement of fitness in yellow-bellied marmots.

    PubMed

    Armitage, K B; Schwartz, O A

    2000-10-24

    The yellow-bellied marmot (Marmota flaviventris) is a social, ground-dwelling squirrel that lives either individually or in kin groups of from two to five adult females. Philopatry and daughter recruitment lead to the formation and persistence of matrilines at habitat sites. By using 37 years of demographic data for 12 habitat sites, we could determine long-term trends in the effects of group size on two measures of fitness, survivorship and net reproductive rate, which otherwise are obscured by annual fluctuations in these measures. Both size and number of matrilines varied among sites and survivorship and net reproductive rate varied among sites and among matriline sizes. The role of social organization was explored further by examining the effect of matriline size, averaged over all years and sites, on fitness. For both survivorship and net reproductive rate the relationship with matriline size was curvilinear. Fitness increased with the increase in matriline size and then decreased in the largest groups. Decreased fitness in matrilines of four or five was associated with agonistic behavior, a large number of 2-year-old females in the social group, and reproductive suppression. There is no evidence that females acted to increase their fitness by increasing indirect fitness; i.e., by assisting relatives, but attempted to increase direct fitness. Direct fitness increased when mortality and fission of large matrilines reduced group size and the surviving females increased reproduction.

  6. Social enhancement of fitness in yellow-bellied marmots

    PubMed Central

    Armitage, Kenneth B.; Schwartz, Orlando A.

    2000-01-01

    The yellow-bellied marmot (Marmota flaviventris) is a social, ground-dwelling squirrel that lives either individually or in kin groups of from two to five adult females. Philopatry and daughter recruitment lead to the formation and persistence of matrilines at habitat sites. By using 37 years of demographic data for 12 habitat sites, we could determine long-term trends in the effects of group size on two measures of fitness, survivorship and net reproductive rate, which otherwise are obscured by annual fluctuations in these measures. Both size and number of matrilines varied among sites and survivorship and net reproductive rate varied among sites and among matriline sizes. The role of social organization was explored further by examining the effect of matriline size, averaged over all years and sites, on fitness. For both survivorship and net reproductive rate the relationship with matriline size was curvilinear. Fitness increased with the increase in matriline size and then decreased in the largest groups. Decreased fitness in matrilines of four or five was associated with agonistic behavior, a large number of 2-year-old females in the social group, and reproductive suppression. There is no evidence that females acted to increase their fitness by increasing indirect fitness; i.e., by assisting relatives, but attempted to increase direct fitness. Direct fitness increased when mortality and fission of large matrilines reduced group size and the surviving females increased reproduction. PMID:11035771

  7. Cobble cam: Grain-size measurements of sand to boulder from digital photographs and autocorrelation analyses

    USGS Publications Warehouse

    Warrick, J.A.; Rubin, D.M.; Ruggiero, P.; Harney, J.N.; Draut, A.E.; Buscombe, D.

    2009-01-01

    A new application of the autocorrelation grain size analysis technique for mixed to coarse sediment settings has been investigated. Photographs of sand- to boulder-sized sediment along the Elwha River delta beach were taken from approximately 1??2 m above the ground surface, and detailed grain size measurements were made from 32 of these sites for calibration and validation. Digital photographs were found to provide accurate estimates of the long and intermediate axes of the surface sediment (r2 > 0??98), but poor estimates of the short axes (r2 = 0??68), suggesting that these short axes were naturally oriented in the vertical dimension. The autocorrelation method was successfully applied resulting in total irreducible error of 14% over a range of mean grain sizes of 1 to 200 mm. Compared with reported edge and object-detection results, it is noted that the autocorrelation method presented here has lower error and can be applied to a much broader range of mean grain sizes without altering the physical set-up of the camera (~200-fold versus ~6-fold). The approach is considerably less sensitive to lighting conditions than object-detection methods, although autocorrelation estimates do improve when measures are taken to shade sediments from direct sunlight. The effects of wet and dry conditions are also evaluated and discussed. The technique provides an estimate of grain size sorting from the easily calculated autocorrelation standard error, which is correlated with the graphical standard deviation at an r2 of 0??69. The technique is transferable to other sites when calibrated with linear corrections based on photo-based measurements, as shown by excellent grain-size analysis results (r2 = 0??97, irreducible error = 16%) from samples from the mixed grain size beaches of Kachemak Bay, Alaska. Thus, a method has been developed to measure mean grain size and sorting properties of coarse sediments. ?? 2009 John Wiley & Sons, Ltd.

  8. Optical properties of mineral dust aerosol including analysis of particle size, composition, and shape effects, and the impact of physical and chemical processing

    NASA Astrophysics Data System (ADS)

    Alexander, Jennifer Mary

    Atmospheric mineral dust has a large impact on the earth's radiation balance and climate. The radiative effects of mineral dust depend on factors including, particle size, shape, and composition which can all be extremely complex. Mineral dust particles are typically irregular in shape and can include sharp edges, voids, and fine scale surface roughness. Particle shape can also depend on the type of mineral and can vary as a function of particle size. In addition, atmospheric mineral dust is a complex mixture of different minerals as well as other, possibly organic, components that have been mixed in while these particles are suspended in the atmosphere. Aerosol optical properties are investigated in this work, including studies of the effect of particle size, shape, and composition on the infrared (IR) extinction and visible scattering properties in order to achieve more accurate modeling methods. Studies of particle shape effects on dust optical properties for single component mineral samples of silicate clay and diatomaceous earth are carried out here first. Experimental measurements are modeled using T-matrix theory in a uniform spheroid approximation. Previous efforts to simulate the measured optical properties of silicate clay, using models that assumed particle shape was independent of particle size, have achieved only limited success. However, a model which accounts for a correlation between particle size and shape for the silicate clays offers a large improvement over earlier modeling approaches. Diatomaceous earth is also studied as an example of a single component mineral dust aerosol with extreme particle shapes. A particle shape distribution, determined by fitting the experimental IR extinction data, used as a basis for modeling the visible light scattering properties. While the visible simulations show only modestly good agreement with the scattering data, the fits are generally better than those obtained using more commonly invoked particle shape distributions. The next goal of this work is to investigate if modeling methods developed in the studies of single mineral components can be generalized to predict the optical properties of more authentic aerosol samples which are complex mixtures of different minerals. Samples of Saharan sand, Iowa loess, and Arizona road dust are used here as test cases. T-matrix based simulations of the authentic samples, using measured particle size distributions, empirical mineralogies, and a priori particle shape models for each mineral component are directly compared with the measured IR extinction spectra and visible scattering profiles. This modeling approach offers a significant improvement over more commonly applied models that ignore variations in particle shape with size or mineralogy and include only a moderate range of shape parameters. Mineral dust samples processed with organic acids and humic material are also studied in order to explore how the optical properties of dust can change after being aged in the atmosphere. Processed samples include quartz mixed with humic material, and calcite reacted with acetic and oxalic acid. Clear differences in the light scattering properties are observed for all three processed mineral dust samples when compared to the unprocessed mineral dust or organic salt products. These interactions result in both internal and external mixtures depending on the sample. In addition, the presence of these organic materials can alter the mineral dust particle shape. Overall, however, these results demonstrate the need to account for the effects of atmospheric aging of mineral dust on aerosol optical properties. Particle shape can also affect the aerodynamic properties of mineral dust aerosol. In order to account for these effects, the dynamic shape factor is used to give a measure of particle asphericity. Dynamic shape factors of quartz are measured by mass and mobility selecting particles and measuring their vacuum aerodynamic diameter. From this, dynamic shape factors in both the transition and vacuum regime can be derived. The measured dynamic shape factors of quartz agree quite well with the spheroidal shape distributions derived through studies of the optical properties.

  9. Influence of feedstock particle size on lignocellulose conversion--a review.

    PubMed

    Vidal, Bernardo C; Dien, Bruce S; Ting, K C; Singh, Vijay

    2011-08-01

    Feedstock particle sizing can impact the economics of cellulosic ethanol commercialization through its effects on conversion yield and energy cost. Past studies demonstrated that particle size influences biomass enzyme digestibility to a limited extent. Physical size reduction was able to increase conversion rates to maximum of ≈ 50%, whereas chemical modification achieved conversions of >70% regardless of biomass particle size. This suggests that (1) mechanical pretreatment by itself is insufficient to attain economically feasible biomass conversion, and, therefore, (2) necessary particle sizing needs to be determined in the context of thermochemical pretreatment employed for lignocellulose conversion. Studies of thermochemical pretreatments that have taken into account particle size as a factor have exhibited a wide range of maximal sizes (i.e., particle sizes below which no increase in pretreatment effectiveness, measured in terms of the enzymatic conversion resulting from the pretreatment, were observed) from <0.15 to 50 mm. Maximal sizes as defined above were dependent on the pretreatment employed, with maximal size range decreasing as follows: steam explosion > liquid hot water > dilute acid and base pretreatments. Maximal sizes also appeared dependent on feedstock, with herbaceous or grassy biomass exhibiting lower maximal size range (<3 mm) than woody biomass (>3 mm). Such trends, considered alongside the intensive energy requirement of size reduction processes, warrant a more systematic study of particle size effects across different pretreatment technologies and feedstock, as a requisite for optimizing the feedstock supply system.

  10. Detailed investigation of a vaporising fuel spray. Part 1: Experimental investigation of time averaged spray

    NASA Technical Reports Server (NTRS)

    Yule, A. J.; Seng, C. A.; Boulderstone, R.; Ungut, A.; Felton, P. G.; Chigier, N. A.

    1980-01-01

    A laser tomographic light scattering technique provides rapid and accurate high resolution measurements of droplet sizes, concentrations, and vaporization. Measurements using a computer interfaced thermocouple are presented and it is found that the potential exists for separating gas and liquid temperature measurements and diagnosing local spray density by in situ analysis of the response characteristics of the thermocouple. The thermocouple technique provides a convenient means for measuring mean gas velocity in both hot and cold two phase flows. The experimental spray is axisymmetric and has carefully controlled initial and boundary conditions. The flow is designed to give relatively insignificant transfer of momentum and mass from spray to air flow. The effects of (1) size-dependent droplet dispersion by the turbulence, (2) the initial spatial segregation of droplet sizes during atomization, and (3) the interaction between droplets and coherent large eddies are diagnosed.

  11. Dimethylsulfide/cloud condensation nuclei/climate system - Relevant size-resolved measurements of the chemical and physical properties of atmospheric aerosol particles

    NASA Technical Reports Server (NTRS)

    Quinn, P. K.; Covert, D. S.; Bates, T. S.; Kapustin, V. N.; Ramsey-Bell, D. C.; Mcinnes, L. M.

    1993-01-01

    The mass and number relationships occurring within the atmospheric dimethylsulfide/cloud condensation nuclei (CCN)/climate system, using simultaneous measurements of particulate phase mass size distributions of nss SO4(2-), methanesulfonic acid (MSA), and NH4(+); number size distributions of particles having diameters between 0.02 and 9.6 microns; CCN concentrations at a supersaturation of 0.3 percent; relative humidity; and temperature, obtained for the northeastern Pacific Ocean in April and May 1991. Based on these measurements, particulate nss SO4(2-), MSA, and NH4(+) mass appeared to be correlated with both particle effective surface area and number in the accumulation mode size range (0.16 to 0.5 micron). No correlations were found in the size range below 0.16 micron. A correlation was also found between nss SO4(2-) mass and the CCN number concentration, such that a doubling of the SO4(2-) mass corresponded to a 40 percent increase in the CCN number concentration. However, no correlation was found between MSA mass and CCN concentration.

  12. [The effect of disinfectant soaking on dental gypsum model size].

    PubMed

    Zhu, Cao-yun; Xu, Yun-wen; Xu, Kan

    2012-12-01

    To study the influence of disinfectant soaking on the dimensional stability of three kinds of dental gypsum model. Three commonly used gypsums ( type III,IV,Vtype) in clinic were used to make 24 specimens for 50 mm×15 mm×10 mm in size. One hour after release, the specimens were placed for 24 h. A digital caliper was used to measure the size of the gypsum model. Distilled water immersion was as used control, glutaraldehyde disinfectant and Metrix CaviCide disinfectant soaking were used for the experimental group. After soaking for 0.5h, the gypsum models were removed and placed for 0.5 h, 1 h, 2 h, 24 h. The size of the models was measured again using the same method. The data was analyzed with SPSS10.0 software package. The initial gypsum model length was (50.07±0.017) mm, (50.048±0.015) mm and (50.027±0.015) mm. After soaking for different times, the size of the model changed little, and the dimensions changed less than 0.01%. The results show that disinfectant soaking has no significant effect on dental model dimensions.

  13. The effect of cuff presence and cuff inflation on airway pressure in a canine tracheostomy tube model.

    PubMed

    Wignall, Jamie R; Baines, Stephen J

    2014-01-01

    To evaluate the effect of cuff presence and cuff inflation on airway pressure in an inspiratory model of canine tracheostomy. Ex vivo experimental study. Cadaver tracheas from Beagle dogs were attached aborally to a vacuum. Airway pressure and flow rate was measured before and after placement of tracheostomy tubes. None. Adult uncuffed tubes and cuffed tracheostomy tubes (sizes 4, 6, 8, and 10) were placed within tracheas. Cuffs were investigated without inflation and at maximum cuff inflation. Airway pressure was measured at constant airflow rates at 30 and 60 L/min. At set flow rates, airway pressures of tracheostomy tubes were compared to the intact trachea. A size 4 uncuffed tracheostomy tube showed the lowest airway pressure and a size 4 cuffed trachestomy tube with inflation showed the highest airway pressures. For sizes 6, 8, and 10 tubes, the presence of a cuff with and without inflation significantly increased airway pressure. Inflation of a cuff always significantly increased airway pressure. Similar pressure is seen between sizes 4 and 6 uncuffed tubes. Cuffed tracheostomy tubes should not be used unless specifically indicated due to increased airway pressure. © Veterinary Emergency and Critical Care Society 2013.

  14. Eating less from bigger packs: Preventing the pack size effect with diet primes.

    PubMed

    Versluis, Iris; Papies, Esther K

    2016-05-01

    An increase in the package size of food has been shown to lead to an increase in energy intake from this food, the so-called pack size effect. Previous research has shown that providing diet-concerned individuals with a reminder, or prime, of their dieting goal can help them control their consumption. Here, we investigated if providing such a prime is also effective for reducing the magnitude of the pack size effect. We conducted two experiments in which the cover of a dieting magazine (Experiment 1) and diet-related commercials (Experiment 2) served as diet goal primes. Both experiments had a 2 (pack size: small vs. large) × 2 (prime: diet vs. control) × 2 (dietary restraint: high vs. low) between participants design. We measured expected consumption of four snack foods in Experiment 1 (N = 477), and actual consumption of M&M's in Experiment 2 (N = 224). Results showed that the diet prime reduced the pack size effect for both restrained and unrestrained eaters in Experiment 1 and for restrained eaters only in Experiment 2. Although effect sizes were small, these findings suggest that a diet prime motivates restrained eaters to limit their consumption, and as a result the pack size has less influence on the amount consumed. We discuss limitations of this research as well as potential avenues for further research and theoretical and practical implications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. Garment sizes in perception of body size.

    PubMed

    Fan, Jintu; Newton, Edward; Lau, Lilian; Liu, Fu

    2003-06-01

    This paper reports an experimental investigation of the effect of garment size on perceived body size. The perceived body sizes of three Chinese men (thin, medium, and obese build) wearing different sizes of white T-shirts were assessed using Thompson and Gray's 1995 Nine-figural Scale in 1 (thinnest) to 9 (obese) grade and a newly-proposed method. Within the limit of commercially available T-shirt sizes, for thin and medium persons, perceived body sizes are bigger when wearing T-shirts of larger sizes. For an obese person, however, wearing a large size T-shirt tends to make him look thinner. The study also showed that the newly proposed comparative method is more reliable in comparing body size perception but without measuring the magnitude of the change in body-size grade. The figural scale and the comparative method can be complementary.

  16. Characterizing tissue microstructure using an ultrasound system-independent spatial autocorrelation function

    NASA Astrophysics Data System (ADS)

    Dong, Fang

    1999-09-01

    The research described in this dissertation is related to characterization of tissue microstructure using a system- independent spatial autocorrelation function (SAF). The function was determined using a reference phantom method, which employed a well-defined ``point- scatterer'' reference phantom to account for instrumental factors. The SAF's were estimated for several tissue-mimicking (TM) phantoms and fresh dog livers. Both phantom tests and in vitro dog liver measurements showed that the reference phantom method is relatively simple and fairly accurate, providing the bandwidth of the measurement system is sufficient for the size of the scatterer being involved in the scattering process. Implementation of this method in clinical scanner requires that distortions from patient's body wall be properly accounted for. The SAF's were estimated for two phantoms with body-wall-like distortions. The experimental results demonstrated that body wall distortions have little effect if echo data are acquired from a large scattering volume. One interesting application of the SAF is to form a ``scatterer size image''. The scatterer size image may help providing diagnostic tools for those diseases in which the tissue microstructure is different from the normal. Another method, the BSC method, utilizes information contained in the frequency dependence of the backscatter coefficient to estimate the scatterer size. The SAF technique produced accurate scatterer size images of homogeneous TM phantoms and the BSC method was capable of generating accurate size images for heterogeneous phantoms. In the scatterer size image of dog kidneys, the contrast-to-noise-ratio (CNR) between renal cortex and medulla was improved dramatically compared to the gray- scale image. The effect of nonlinear propagation was investigated by using a custom-designed phantom with overlaying TM fat layer. The results showed that the correlation length decreased when the transmitting power increased. The measurement results support the assumption that nonlinear propagation generates harmonic energies and causes underestimation of scatterer diameters. Nonlinear propagation can be further enhanced by those materials with high B/A value-a parameter which characterizes the degree of nonlinearity. Nine versions of TM fat and non-fat materials were measured for their B/A values using a new measurement technique, the ``simplified finite amplitude insertion substitution'' (SFAIS) method.

  17. Effect size comparison of ketorolac nasal spray and commonly prescribed oral combination opioids for pain relief after third molar extraction surgery.

    PubMed

    Niebler, Gwendolyn; Dayno, Jeffrey

    2016-01-01

    Opioids are frequently used for treatment of moderate to severe short-term pain, but concerns exist about this treatment approach. Ketorolac tromethamine nasal spray, a nonsteroidal anti-inflammatory, is indicated for the short-term management of moderate to moderately severe pain requiring analgesia at the opioid level. However, there are no direct comparison studies between ketorolac nasal spray and opioids. The objective of this study was to use an effect size analysis to compare the effectiveness of ketorolac nasal spray with oral combination opioid formulations in treating moderate to severe short-term pain. An effect size analysis of three randomized, double-blind, placebo-controlled studies of third molar extraction surgery compared pain relief with ketorolac nasal spray and commonly prescribed combination opioids including hydrocodone/acetaminophen (APAP), oxycodone/APAP, oxycodone/ibuprofen and tramadol HCl/APAP. Effect size comparisons were made using total pain relief scores (TOTPAR6 or TOTPAR8; the weighted sum of pain relief scores through 6 or 8 h). Pain relief was measured using a five-point categorical rating scale (0 = none; 4 = complete). The effect size equivalent correlation, r, was determined using an online effect size calculator. The treatment effect size r compared with placebo was classified using established criteria (small = 0.20-0.49, moderate = 0.50-0.79 and large = ≥ 0.80). TOTPAR6 data indicated a moderate effect size for ketorolac nasal spray 31.5 mg (0.51) and oxycodone/ibuprofen 5/400 mg (0.64) and a small effect size for hydrocodone/APAP 7.5/500 mg (0.24) and oxycodone/APAP 5/325 mg (0.32). TOTPAR8 data indicated small effect sizes for ketorolac nasal spray (0.48), hydrocodone/APAP 10/650 mg (0.43), tramadol HCl/APAP 75/650 mg (0.35) and tramadol HCl/APAP 37.5/325 mg (0.17). The treatment effect sizes of ketorolac nasal spray were similar to or higher than the opioid comparators after third molar surgery, a well-accepted pain model. These results support ketorolac nasal spray as an effective treatment for moderate to moderately severe short-term pain.

  18. Replication Validity of Initial Association Studies: A Comparison between Psychiatry, Neurology and Four Somatic Diseases.

    PubMed

    Dumas-Mallet, Estelle; Button, Katherine; Boraud, Thomas; Munafo, Marcus; Gonon, François

    2016-01-01

    There are growing concerns about effect size inflation and replication validity of association studies, but few observational investigations have explored the extent of these problems. Using meta-analyses to measure the reliability of initial studies and explore whether this varies across biomedical domains and study types (cognitive/behavioral, brain imaging, genetic and "others"). We analyzed 663 meta-analyses describing associations between markers or risk factors and 12 pathologies within three biomedical domains (psychiatry, neurology and four somatic diseases). We collected the effect size, sample size, publication year and Impact Factor of initial studies, largest studies (i.e., with the largest sample size) and the corresponding meta-analyses. Initial studies were considered as replicated if they were in nominal agreement with meta-analyses and if their effect size inflation was below 100%. Nominal agreement between initial studies and meta-analyses regarding the presence of a significant effect was not better than chance in psychiatry, whereas it was somewhat better in neurology and somatic diseases. Whereas effect sizes reported by largest studies and meta-analyses were similar, most of those reported by initial studies were inflated. Among the 256 initial studies reporting a significant effect (p<0.05) and paired with significant meta-analyses, 97 effect sizes were inflated by more than 100%. Nominal agreement and effect size inflation varied with the biomedical domain and study type. Indeed, the replication rate of initial studies reporting a significant effect ranged from 6.3% for genetic studies in psychiatry to 86.4% for cognitive/behavioral studies. Comparison between eight subgroups shows that replication rate decreases with sample size and "true" effect size. We observed no evidence of association between replication rate and publication year or Impact Factor. The differences in reliability between biological psychiatry, neurology and somatic diseases suggest that there is room for improvement, at least in some subdomains.

  19. Replication Validity of Initial Association Studies: A Comparison between Psychiatry, Neurology and Four Somatic Diseases

    PubMed Central

    Dumas-Mallet, Estelle; Button, Katherine; Boraud, Thomas; Munafo, Marcus; Gonon, François

    2016-01-01

    Context There are growing concerns about effect size inflation and replication validity of association studies, but few observational investigations have explored the extent of these problems. Objective Using meta-analyses to measure the reliability of initial studies and explore whether this varies across biomedical domains and study types (cognitive/behavioral, brain imaging, genetic and “others”). Methods We analyzed 663 meta-analyses describing associations between markers or risk factors and 12 pathologies within three biomedical domains (psychiatry, neurology and four somatic diseases). We collected the effect size, sample size, publication year and Impact Factor of initial studies, largest studies (i.e., with the largest sample size) and the corresponding meta-analyses. Initial studies were considered as replicated if they were in nominal agreement with meta-analyses and if their effect size inflation was below 100%. Results Nominal agreement between initial studies and meta-analyses regarding the presence of a significant effect was not better than chance in psychiatry, whereas it was somewhat better in neurology and somatic diseases. Whereas effect sizes reported by largest studies and meta-analyses were similar, most of those reported by initial studies were inflated. Among the 256 initial studies reporting a significant effect (p<0.05) and paired with significant meta-analyses, 97 effect sizes were inflated by more than 100%. Nominal agreement and effect size inflation varied with the biomedical domain and study type. Indeed, the replication rate of initial studies reporting a significant effect ranged from 6.3% for genetic studies in psychiatry to 86.4% for cognitive/behavioral studies. Comparison between eight subgroups shows that replication rate decreases with sample size and “true” effect size. We observed no evidence of association between replication rate and publication year or Impact Factor. Conclusion The differences in reliability between biological psychiatry, neurology and somatic diseases suggest that there is room for improvement, at least in some subdomains. PMID:27336301

  20. Sex differences in the adolescent brain and body: Findings from the saguenay youth study.

    PubMed

    Paus, Tomáš; Wong, Angelita Pui-Yee; Syme, Catriona; Pausova, Zdenka

    2017-01-02

    This Mini-Review describes sex differences in 66 quantitative characteristics of the brain and body measured in a community-based sample of 1,024 adolescents 12-18 years of age, members of the Saguenay Youth Study. Using an extensive phenotyping protocol, we have obtained measures in a number of domains, including brain structure, cognition, mental health, substance use, body composition, metabolism, cardiovascular reactivity, and life style. For each measure, we provide estimates of effect size (Cohen's d) and sex-specific correlations with age (Pearson R). In total 59 of the 66 characteristics showed sex differences (at a nominal P < 0.05), with small (32), medium-sized (13), and large (11) effects. Some, but not all, of these sex differences increase during adolescence; this appears to be the case mostly for anatomical and physiological measures. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  1. Measuring culture outside the head: a meta-analysis of individualism-collectivism in cultural products.

    PubMed

    Morling, Beth; Lamoreaux, Marika

    2008-08-01

    Although cultural psychology is the study of how sociocultural environments and psychological processes coconstruct each other, the field has traditionally emphasized measures of the psychological over the sociocultural. Here, the authors call attention to a growing trend of measuring the sociocultural environment. They present a quantitative review of studies that measure cultural differences in "cultural products": tangible, public representations of culture such as advertising or popular texts. They found that cultural products that come from Western cultures (mostly the United States) are more individualistic, and less collectivistic, than cultural products that come from collectivistic cultures (including Korea, Japan, China, and Mexico). The effect sizes for cultural products were larger than self-report effect sizes for this dimension (reported in Oyserman, Coon, & Kemmelmeier, 2002). In addition to presenting this evidence, the authors highlight the importance of studying the dynamic relationships between sociocultural environments and psyches.

  2. Cumulative meta-analysis of the relationship between useful field of view and driving performance in older adults: current and future implications.

    PubMed

    Clay, Olivio J; Wadley, Virginia G; Edwards, Jerri D; Roth, David L; Roenker, Daniel L; Ball, Karlene K

    2005-08-01

    Driving is a complex behavior that requires the utilization of a wide range of individual abilities. Identifying assessments that not only capture individual differences, but also are related to older adults' driving performance would be beneficial. This investigation examines the relationship between the Useful Field of View (UFOV) assessment and objective measures of retrospective or concurrent driving performance, including state-recorded accidents, on-road driving, and driving simulator performance. The PubMed and PsycINFO databases were searched to retrieve eight studies that reported bivariate relationships between UFOV and these objective driving measures. Cumulative meta-analysis techniques were used to combine the effect sizes in an attempt to determine whether the strength of the relationship was stable across studies and to assess whether a sufficient number of studies have been conducted to validate the relationship between UFOV and driving performance. A within-group homogeneity of effect sizes test revealed that the samples could be thought of as being drawn from the same population, Q [7] = 11.29, p (one-tailed) = 0.13. Therefore, the effect sizes of eight studies were combined for the present cumulative meta-analysis. The weighted mean effect size across the studies revealed a large effect (Cohen's d = 0.945), with poorer UFOV performance associated with negative driving outcomes. This relationship was robust across multiple indices of driving performance and several research laboratories. This convergence of evidence across numerous studies using different methodologies confirms the importance of the UFOV assessment as a valid and reliable index of driving performance and safety. Recent prospective studies have confirmed a relationship between UFOV performance and future crashes, further supporting the use of this instrument as a potential screening measure for at-risk older drivers.

  3. Size and consistency of problem-solving consultation outcomes: an empirical analysis.

    PubMed

    Hurwitz, Jason T; Kratochwill, Thomas R; Serlin, Ronald C

    2015-04-01

    In this study, we analyzed extant data to evaluate the variability and magnitude of students' behavior change outcomes (academic, social, and behavioral) produced by consultants through problem-solving consultation with teachers. Research questions were twofold: (a) Do consultants produce consistent and sizeable positive student outcomes across their cases as measured through direct and frequent assessment? and (b) What proportion of variability in student outcomes is attributable to consultants? Analyses of extant data collected from problem-solving consultation outcome studies that used single-case, time-series AB designs with multiple participants were analyzed. Four such studies ultimately met the inclusion criteria for the extant data, comprising 124 consultants who worked with 302 school teachers regarding 453 individual students. Consultants constituted the independent variable, while the primary dependent variable was a descriptive effect size based on student behavior change as measured by (a) curriculum-based measures, (b) permanent products, or (c) direct observations. Primary analyses involved visual and statistical evaluation of effect size magnitude and variability observed within and between consultants and studies. Given the nested nature of the data, multilevel analyses were used to assess consultant effects on student outcomes. Results suggest that consultants consistently produced positive effect sizes on average across their cases, but outcomes varied between consultants. Findings also indicated that consultants, teachers, and the corresponding studies accounted for a significant proportion of variability in student outcomes. This investigation advances the use of multilevel and integrative data analyses to evaluate consultation outcomes and extends research on problem-solving consultation, consultant effects, and meta-analysis of case study AB designs. Practical implications for evaluating consultation service delivery in school settings are also discussed. Copyright © 2015 Society for the Study of School Psychology. Published by Elsevier Ltd. All rights reserved.

  4. Viscosity Analysis of Dual Variable Domain Immunoglobulin Protein Solutions: Role of Size, Electroviscous Effect and Protein-Protein Interactions.

    PubMed

    Raut, Ashlesha S; Kalonia, Devendra S

    2016-01-01

    Increased solution viscosity results in difficulties in manufacturing and delivery of therapeutic protein formulations, increasing both the time and production costs, and leading to patient inconvenience. The solution viscosity is affected by the molecular properties of both the solute and the solvent. The purpose of this work was to investigate the effect of size, charge and protein-protein interactions on the viscosity of Dual Variable Domain Immunoglobulin (DVD-Ig(TM)) protein solutions. The effect of size of the protein molecule on solution viscosity was investigated by measuring intrinsic viscosity and excluded volume calculations for monoclonal antibody (mAb) and DVD-Ig(TM) protein solutions. The role of the electrostatic charge resulting in electroviscous effects for DVD-Ig(TM) protein was assessed by measuring zeta potential. Light scattering measurements were performed to detect protein-protein interactions affecting solution viscosity. DVD-Ig(TM) protein exhibited significantly higher viscosity compared to mAb. Intrinsic viscosity and excluded volume calculations indicated that the size of the molecule affects viscosity significantly at higher concentrations, while the effect was minimal at intermediate concentrations. Electroviscous contribution to the viscosity of DVD-Ig(TM) protein varied depending on the presence or absence of ions in the solution. In buffered solutions, negative k D and B 2 values indicated the presence of attractive interactions which resulted in high viscosity for DVD-Ig(TM) protein at certain pH and ionic strength conditions. Results show that more than one factor contributes to the increased viscosity of DVD-Ig(TM) protein and interplay of these factors modulates the overall viscosity behavior of the solution, especially at higher concentrations.

  5. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data

    PubMed Central

    Hsiao, Yu-Yu; Lai, Mark H. C.

    2018-01-01

    Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a) To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b) To examine whether unique features of multilevel data, such as intraclass correlation (ICC) and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions) for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (non)invariance structure of the predictor and/or the outcome is recommended. PMID:29867692

  6. The Impact of Partial Measurement Invariance on Testing Moderation for Single and Multi-Level Data.

    PubMed

    Hsiao, Yu-Yu; Lai, Mark H C

    2018-01-01

    Moderation effect is a commonly used concept in the field of social and behavioral science. Several studies regarding the implication of moderation effects have been done; however, little is known about how partial measurement invariance influences the properties of tests for moderation effects when categorical moderators were used. Additionally, whether the impact is the same across single and multilevel data is still unknown. Hence, the purpose of the present study is twofold: (a) To investigate the performance of the moderation test in single-level studies when measurement invariance does not hold; (b) To examine whether unique features of multilevel data, such as intraclass correlation (ICC) and number of clusters, influence the effect of measurement non-invariance on the performance of tests for moderation. Simulation results indicated that falsely assuming measurement invariance lead to biased estimates, inflated Type I error rates, and more gain or more loss in power (depends on simulation conditions) for the test of moderation effects. Such patterns were more salient as sample size and the number of non-invariant items increase for both single- and multi-level data. With multilevel data, the cluster size seemed to have a larger impact than the number of clusters when falsely assuming measurement invariance in the moderation estimation. ICC was trivially related to the moderation estimates. Overall, when testing moderation effects with categorical moderators, employing a model that accounts for the measurement (non)invariance structure of the predictor and/or the outcome is recommended.

  7. Measurements of droplet size in shear-driven atomization using ultra-small angle x-ray scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kastengren, A.; Ilavsky, J.; Viera, Juan Pablo

    Measurements of droplet size in optically-thick, non-evaporating, shear-driven sprays have been made using ultra-small angle x-ray scattering (USAXS). The sprays are produced by orifice-type nozzles coupled to diesel injectors, with measurements conducted from 1 – 24 mm from the orifice, spanning from the optically-dense near-nozzle region to more dilute regions where optical diagnostics are feasible. The influence of nozzle diameter, liquid injection pressure, and ambient density were examined. The USAXS measurements reveal few if any nanoscale droplets, in conflict with a popular computational model of diesel spray breakup. The average droplet diameter rapidly decreases with downstream distance from the nozzlemore » until a plateau value is reached, after which only small changes are seen in droplet diameter. This plateau droplet size is consistent with the droplets being small enough to be stable with respect to further breakup. As a result, liquid injection pressure and nozzle diameter have the biggest impact on droplet size, while ambient density has a smaller effect.« less

  8. Measurements of droplet size in shear-driven atomization using ultra-small angle x-ray scattering

    DOE PAGES

    Kastengren, A.; Ilavsky, J.; Viera, Juan Pablo; ...

    2017-03-16

    Measurements of droplet size in optically-thick, non-evaporating, shear-driven sprays have been made using ultra-small angle x-ray scattering (USAXS). The sprays are produced by orifice-type nozzles coupled to diesel injectors, with measurements conducted from 1 – 24 mm from the orifice, spanning from the optically-dense near-nozzle region to more dilute regions where optical diagnostics are feasible. The influence of nozzle diameter, liquid injection pressure, and ambient density were examined. The USAXS measurements reveal few if any nanoscale droplets, in conflict with a popular computational model of diesel spray breakup. The average droplet diameter rapidly decreases with downstream distance from the nozzlemore » until a plateau value is reached, after which only small changes are seen in droplet diameter. This plateau droplet size is consistent with the droplets being small enough to be stable with respect to further breakup. As a result, liquid injection pressure and nozzle diameter have the biggest impact on droplet size, while ambient density has a smaller effect.« less

  9. Heat increment of feeding in Steller sea lions, Eumetopias jubatus.

    PubMed

    Rosen, D A; Trites, A W

    1997-11-01

    The heat increment of feeding (HIF) was measured in six captive, juvenile Steller sea lions (Eumetopias jubatus), fed meals of either 2 or 4 kg of herring. HIF was calculated as the post-prandial increase in metabolism above baseline levels, and was measured using open-circuit (gas) respirometry. It averaged 12.4 +/- 0.9% (SE) of ingested energy intake for the 4-kg meal trials, and 9.9 +/- 0.9% for the 2-kg meal size. The effect lasted 8-10 hr for the larger meal size. Metabolism peaked 3.7 hr after feeding, and was 2.13 times higher than baseline levels. For the 2-kg meal size, the effect lasted 6-8 hr, with metabolism peaking 2.8 hr after ingestion at 1.76 times baseline levels. Our estimates of HIF for Steller sea lions are at the lower end of estimates for terrestrial mammals, and are consistent with estimates for other marine mammals.

  10. Measuring lip force by oral screens. Part 1: Importance of screen size and individual variability.

    PubMed

    Wertsén, Madeleine; Stenberg, Manne

    2017-06-01

    To reduce drooling and facilitate food transport in rehabilitation of patients with oral motor dysfunction, lip force can be trained using an oral screen. Longitudinal studies evaluating the effect of training require objective methods. The aim of this study was to evaluate a method for measuring lip strength, to investigate normal values and fluctuation of lip force in healthy adults on 1 occasion and over time, to study how the size of the screen affects the force, to evaluate the most appropriate measure of reliability, and to identify force performed in relation to gender. Three different sizes of oral screens were used to measure the lip force for 24 healthy adults on 3 different occasions, during a period of 6 months, using an apparatus based on strain gauge. The maximum lip force as evaluated with this method depends on the area of the screen size. By calculating the projected area of the screen, the lip force could be normalized to an oral screen pressure quantity expressed in kPa, which can be used for comparing measurements from screens with different sizes. Both the mean value and standard deviation were shown to vary between individuals. The study showed no differences regarding gender and only small variation with age. Normal variation over time (months) may be up to 3 times greater than the standard error of measurement at a certain occasion. The lip force increases in relation to the projected area of the screen. No general standard deviation can be assigned to the method and all measurements should be analyzed individually based on oral screen pressure to compensate for different screen sizes.

  11. Acute effects of tea constituents L-theanine, caffeine, and epigallocatechin gallate on cognitive function and mood: a systematic review and meta-analysis.

    PubMed

    Camfield, David A; Stough, Con; Farrimond, Jonathon; Scholey, Andrew B

    2014-08-01

    A systematic review and meta-analysis was conducted on 11 randomized placebo-controlled human studies of acute effects of tea constituents L-theanine and epigallocatechin gallate, administered alone or in combination with caffeine, on cognitive function and mood. The outcome measures of mood were alertness, calmness, and contentedness, derived from the Bond-Lader scales, and state anxiety, from the State-Trait Anxiety Inventory. Cognitive measures assessed were attentional switch, intersensory attention, and rapid visual information processing. Standardized mean differences between placebo and treatment groups are presented for each study and outcome measure. Meta-analysis using a random-effects model was conducted when data were available for three or more studies. Evidence of moderate effect sizes in favor of combined caffeine and L-theanine in the first 2 hours postdose were found for outcome measures Bond-Lader alertness, attentional switching accuracy, and, to a lesser extent, some unisensory and multisensory attentional outcomes. Moderator analysis of caffeine and L-theanine doses revealed trends toward greater change in effect size for caffeine dose than for L-theanine dose, particularly during the first hour postdose. © 2014 International Life Sciences Institute.

  12. Size matters: a meta-analysis on the impact of hospital size on patient mortality.

    PubMed

    Fareed, Naleef

    2012-06-01

    This paper seeks to understand the relationship between hospital size and patient mortality. Patient mortality has been used by several studies in the health services research field as a proxy for measuring healthcare quality. A systematic review is conducted to identify studies that investigate the impact of hospital size on patient mortality. Using the findings of 21 effect sizes from 10 eligible studies, a meta-analysis is performed using a random effects model. Subgroup analyses using three factors--the measure used for hospital size, type of mortality measure used and whether mortality was adjusted or unadjusted--were utilised to investigate their moderating influence on the study's primary relationship. Results from this analysis indicate that big hospitals have lower odds of patient mortality versus small hospitals. Specifically, the probability of patient mortality in a big hospital, in reference to a small hospital, is 11% less. Subgroup analyses show that studies with unadjusted mortality rates have an even lower overall odds ratio of mortality versus studies with adjusted mortality rates. Aside from some limitations in data reporting, the findings of this paper support theoretical notions that big hospitals have lower mortality rates than small hospitals. Guidelines for better data reporting and future research are provided to further explore the phenomenon. Policy implications of this paper's findings are underscored and a sense of urgency is called for in an effort to help improve the state of a healthcare system that struggles with advancing healthcare quality. © 2012 The Author. International Journal of Evidence-Based Healthcare © 2012 The Joanna Briggs Institute.

  13. Sibling Competition & Growth Tradeoffs. Biological vs. Statistical Significance

    PubMed Central

    Kramer, Karen L.; Veile, Amanda; Otárola-Castillo, Erik

    2016-01-01

    Early childhood growth has many downstream effects on future health and reproduction and is an important measure of offspring quality. While a tradeoff between family size and child growth outcomes is theoretically predicted in high-fertility societies, empirical evidence is mixed. This is often attributed to phenotypic variation in parental condition. However, inconsistent study results may also arise because family size confounds the potentially differential effects that older and younger siblings can have on young children’s growth. Additionally, inconsistent results might reflect that the biological significance associated with different growth trajectories is poorly understood. This paper addresses these concerns by tracking children’s monthly gains in height and weight from weaning to age five in a high fertility Maya community. We predict that: 1) as an aggregate measure family size will not have a major impact on child growth during the post weaning period; 2) competition from young siblings will negatively impact child growth during the post weaning period; 3) however because of their economic value, older siblings will have a negligible effect on young children’s growth. Accounting for parental condition, we use linear mixed models to evaluate the effects that family size, younger and older siblings have on children’s growth. Congruent with our expectations, it is younger siblings who have the most detrimental effect on children’s growth. While we find statistical evidence of a quantity/quality tradeoff effect, the biological significance of these results is negligible in early childhood. Our findings help to resolve why quantity/quality studies have had inconsistent results by showing that sibling competition varies with sibling age composition, not just family size, and that biological significance is distinct from statistical significance. PMID:26938742

  14. Sibling Competition & Growth Tradeoffs. Biological vs. Statistical Significance.

    PubMed

    Kramer, Karen L; Veile, Amanda; Otárola-Castillo, Erik

    2016-01-01

    Early childhood growth has many downstream effects on future health and reproduction and is an important measure of offspring quality. While a tradeoff between family size and child growth outcomes is theoretically predicted in high-fertility societies, empirical evidence is mixed. This is often attributed to phenotypic variation in parental condition. However, inconsistent study results may also arise because family size confounds the potentially differential effects that older and younger siblings can have on young children's growth. Additionally, inconsistent results might reflect that the biological significance associated with different growth trajectories is poorly understood. This paper addresses these concerns by tracking children's monthly gains in height and weight from weaning to age five in a high fertility Maya community. We predict that: 1) as an aggregate measure family size will not have a major impact on child growth during the post weaning period; 2) competition from young siblings will negatively impact child growth during the post weaning period; 3) however because of their economic value, older siblings will have a negligible effect on young children's growth. Accounting for parental condition, we use linear mixed models to evaluate the effects that family size, younger and older siblings have on children's growth. Congruent with our expectations, it is younger siblings who have the most detrimental effect on children's growth. While we find statistical evidence of a quantity/quality tradeoff effect, the biological significance of these results is negligible in early childhood. Our findings help to resolve why quantity/quality studies have had inconsistent results by showing that sibling competition varies with sibling age composition, not just family size, and that biological significance is distinct from statistical significance.

  15. Grain size of loess and paleosol samples: what are we measuring?

    NASA Astrophysics Data System (ADS)

    Varga, György; Kovács, János; Szalai, Zoltán; Újvári, Gábor

    2017-04-01

    Particle size falling into a particularly narrow range is among the most important properties of windblown mineral dust deposits. Therefore, various aspects of aeolian sedimentation and post-depositional alterations can be reconstructed only from precise grain size data. Present study is aimed at (1) reviewing grain size data obtained from different measurements, (2) discussing the major reasons for disagreements between data obtained by frequently applied particle sizing techniques, and (3) assesses the importance of particle shape in particle sizing. Grain size data of terrestrial aeolian dust deposits (loess and paleosoil) were determined by laser scattering instruments (Fritsch Analysette 22 Microtec Plus, Horiba Partica La-950 v2 and Malvern Mastersizer 3000 with a Hydro Lv unit), while particles size and shape distributions were acquired by Malvern Morphologi G3-ID. Laser scattering results reveal that the optical parameter settings of the measurements have significant effects on the grain size distributions, especially for the fine-grained fractions (<5 µm). Significant differences between the Mie and Fraunhofer approaches were found for the finest grain size fractions, while only slight discrepancies were observed for the medium to coarse silt fractions. It should be noted that the different instruments provided different grain size distributions even with the exactly same optical settings. Image analysis-based grain size data indicated underestimation of clay and fine silt fractions compared to laser measurements. The measured circle-equivalent diameter of image analysis is calculated from the acquired two-dimensional image of the particle. It is assumed that the instantaneous pulse of compressed air disperse the sedimentary particles onto the glass slide with a consistent orientation with their largest area facing to the camera. However, this is only one outcome of infinite possible projections of a three-dimensional object and it cannot be regarded as a representative one. The third (height) dimension of the particles remains unknown, so the volume-based weightings are fairly dubious in the case of platy particles. Support of the National Research, Development and Innovation Office (Hungary) under contract NKFI 120620 is gratefully acknowledged. It was additionally supported (for G. Varga) by the Bolyai János Research Scholarship of the Hungarian Academy of Sciences.

  16. Particle morphology characterization and manipulation in biomass slurries and the effect on rheological properties and enzymatic conversion.

    PubMed

    Dibble, Clare J; Shatova, Tatyana A; Jorgenson, Jennie L; Stickel, Jonathan J

    2011-01-01

    An improved understanding of how particle size distribution relates to enzymatic hydrolysis performance and rheological properties could enable enhanced biochemical conversion of lignocellulosic feedstocks. Particle size distribution can change as a result of either physical or chemical manipulation of a biomass sample. In this study, we employed image processing techniques to measure slurry particle size distribution and validated the results by showing that they are comparable to those from laser diffraction and sieving. Particle size and chemical changes of biomass slurries were manipulated independently and the resulting yield stress and enzymatic digestibility of slurries with different size distributions were measured. Interestingly, reducing particle size by mechanical means from about 1 mm to 100 μm did not reduce the yield stress of the slurries over a broad range of concentrations or increase the digestibility of the biomass over the range of size reduction studied here. This is in stark contrast to the increase in digestibility and decrease in yield stress when particle size is reduced by dilute-acid pretreatment over similar size ranges. Copyright © 2011 American Institute of Chemical Engineers (AIChE).

  17. Aerosol effect on cloud droplet size as monitored from surface-based remote sensing over East China Sea region

    NASA Astrophysics Data System (ADS)

    Pandithurai, G.; Takamura, T.; Yamaguchi, J.; Miyagi, K.; Takano, T.; Ishizaka, Y.; Dipu, S.; Shimizu, A.

    2009-07-01

    The effect of increased aerosol concentrations on the low-level, non-precipitating, ice-free stratus clouds is examined using a suite of surface-based remote sensing systems. Cloud droplet effective radius and liquid water path are retrieved using cloud radar and microwave radiometer. Collocated measurements of aerosol scattering coefficient, size distribution and cloud condensation nuclei (CCN) concentrations were used to examine the response of cloud droplet size and optical thickness to increased CCN proxies. During the episodic events of increase in aerosol accumulation-mode volume distribution, the decrease in droplet size and increase in cloud optical thickness is observed. The indirect effect estimates are made for both droplet effective radius and cloud optical thickness for different liquid water path ranges and they range 0.02-0.18 and 0.005-0.154, respectively. Data are also categorized into thin and thick clouds based on cloud geometric thickness (Δz) and estimates show IE values are relatively higher for thicker clouds.

  18. Quantum size effect in the photoluminescence properties of p-type semiconducting transparent CuAlO2 nanoparticles

    NASA Astrophysics Data System (ADS)

    Narayan Banerjee, Arghya; Woo Joo, Sang; Min, Bong-Ki

    2012-12-01

    Photoluminescence properties of CuAlO2 nanoparticles, deposited by a cost-effective direct current sputtering technique, have been studied. The nanoparticles show room-temperature photoluminescence peaks of near-band-edge emission due to recombination of free excitons. A blue-shift in the emission peaks as a decreasing function of the nanoparticle sizes is observed, which is attributed to the quantum confinement effect within the CuAlO2 nanoparticles. Theoretical calculations of bandgap enhancement values are found to be matching fairly well with that of the experimentally obtained values, confirming the existence of the quantum size effect within the nanomaterial. Approximate calculations show that the confinement effect falls within moderate-to-weak confinement regime. X-ray diffraction and electron microscopic measurements confirm the proper phase formation and nanocrystalline structure of the as-deposited nanoparticles. The room-temperature and size-dependent photoluminescence properties of this nanomaterial will be very useful for light emitting diode and similar optoelectronic applications.

  19. Computer-Delivered Interventions to Reduce College Student Drinking: A Meta-Analysis

    PubMed Central

    Carey, Kate B.; Scott-Sheldon, Lori A. J.; Elliott, Jennifer C.; Bolles, Jamie R.; Carey, Michael P.

    2009-01-01

    Aims This meta-analysis evaluates the efficacy and moderators of computer-delivered interventions (CDIs) to reduce alcohol use among college students. Methods We included 35 manuscripts with 43 separate interventions, and calculated both between-group and within-group effect sizes for alcohol consumption and alcohol-related problems. Effects sizes were calculated for short-term (≤ 5 weeks) and longer-term (≥ 6 weeks) intervals. All studies were coded for study descriptors, participant characteristics, and intervention components. Results The effects of CDIs depended on the nature of the comparison condition: CDIs reduced quantity and frequency measures relative to assessment-only controls, but rarely differed from comparison conditions that included alcohol content. Small-to-medium within-group effect sizes can be expected for CDIs at short- and longer-term follow-ups; these changes are less than or equivalent to the within-group effect sizes observed for more intensive interventions. Conclusions CDIs reduce the quantity and frequency of drinking among college students. CDIs are generally equivalent to alternative alcohol-related comparison interventions. PMID:19744139

  20. Linking THEMIS Orbital Data to MSL GTS Measurements: The Thermophysical Properties of the Bagnold Dunes, Mars

    NASA Astrophysics Data System (ADS)

    Edwards, C. S.; Piqueux, S.; Hamilton, V. E.; Fergason, R. L.; Herkenhoff, K. E.; Vasavada, A. R.; Sacks, L. E.; Lewis, K. W.; Smith, M. D.

    2017-12-01

    The surface of Mars has been characterized using orbital thermal infrared observations from the time of the Mariner 9 and Viking missions. More recent observations from missions such as the Thermal Emission Spectrometer onboard the Mars Global Surveyor and the Thermal Emission Imaging System (THEMIS) instrument onboard the 2001 Mars Odyssey orbiter have continued to expand global coverage at progressively higher resolution. THEMIS has been producing 100 m/pixel thermal infrared data with nearly global coverage of the surface for >15 years and has enabled new investigations that successfully link outcrop-scale information to physical properties of the surface. However, significant discrepancies between morphologies and interpreted surface properties derived from orbital thermal measurements remain, requiring a robust link to direct surface measurements. Here, we compare the thermophysical properties and particle sizes derived from the Mars Science Laboratory (MSL) rover's Ground Temperature Sensor (GTS), to those derived orbitally from THEMIS, ultimately linking these measurements to ground truth particle sizes determined from Mars Hand Lens Imager (MAHLI) images. We focus on the relatively homogenous Bagnold dunes, specifically Namib dune, and in general find that all three datasets report consistent particle sizes for the Bagnold dunes ( 110-350 µm, and are within measurement and model uncertainties), indicating that particles sizes of homogeneous materials determined from thermal measurements are reliable. In addition, we assess several potentially significant effects that could influence the derived particle sizes, including: 1) fine-scale (cm-m scale) ripples, and 2) thin (mm-cm) layering of indurated/armored materials. To first order, we find that small scale ripples and thin layers do not significantly affect the determination of bulk thermal inertia determined from orbit. However, a layer of coarser/indurated material and/or fine-scale layering does change the shape of a diurnal curve and thus requires multiple time of day observations to constrain these effects. In summary, thermal inertia and grain sizes of relatively homogeneous materials derived from nighttime orbital data should be considered as reliable, as long as there is not significant sub-pixel anisothermality.

  1. Methodological quality of behavioural weight loss studies: a systematic review

    PubMed Central

    Lemon, S. C.; Wang, M. L.; Haughton, C. F.; Estabrook, D. P.; Frisard, C. F.; Pagoto, S. L.

    2018-01-01

    Summary This systematic review assessed the methodological quality of behavioural weight loss intervention studies conducted among adults and associations between quality and statistically significant weight loss outcome, strength of intervention effectiveness and sample size. Searches for trials published between January, 2009 and December, 2014 were conducted using PUBMED, MEDLINE and PSYCINFO and identified ninety studies. Methodological quality indicators included study design, anthropometric measurement approach, sample size calculations, intent-to-treat (ITT) analysis, loss to follow-up rate, missing data strategy, sampling strategy, report of treatment receipt and report of intervention fidelity (mean = 6.3). Indicators most commonly utilized included randomized design (100%), objectively measured anthropometrics (96.7%), ITT analysis (86.7%) and reporting treatment adherence (76.7%). Most studies (62.2%) had a follow-up rate >75% and reported a loss to follow-up analytic strategy or minimal missing data (69.9%). Describing intervention fidelity (34.4%) and sampling from a known population (41.1%) were least common. Methodological quality was not associated with reporting a statistically significant result, effect size or sample size. This review found the published literature of behavioural weight loss trials to be of high quality for specific indicators, including study design and measurement. Identified for improvement include utilization of more rigorous statistical approaches to loss to follow up and better fidelity reporting. PMID:27071775

  2. Theoretical Analysis of Photoelectron Spectra of Pure and Mixed Metal Clusters: Disentangling Size, Structure, and Composition Effects

    DOE PAGES

    Acioli, Paulo H.; Jellinek, Julius

    2017-07-14

    A theoretical/computational description and analysis of the spectra of electron binding energies of Al 12 -, Al 13 - and Al 12Ni- clusters, which differ in size and/or composition by a single atom yet possess strikingly different measured photoelectron spectra, is presented. It is shown that the measured spectra can not only be reproduced computationally with quantitative fidelity – this is achieved through a combination of state-of-the-art density functional theory with a highly accurate scheme for conversion of the Kohn-Sham eigenenergies into electron binding energies – but also explained in terms of the effects of size, structure/symmetry and composition. Furthermore,more » a new methodology is developed and applied that provides for disentanglement and differential assignment of the separate roles played by size, structure/symmetry and composition in defining the observed differences in the measured spectra. The methodology is general and applicable to any finite system, homogeneous or heterogeneous. Finally, we project that in combination with advances in synthesis techniques this methodology will become an indispensable computation-based aid in the design of controlled synthesis protocols for manufacture of nanosystems and nanodevices with precisely desired electronic and other characteristics.« less

  3. Theoretical Analysis of Photoelectron Spectra of Pure and Mixed Metal Clusters: Disentangling Size, Structure, and Composition Effects

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acioli, Paulo H.; Jellinek, Julius

    A theoretical/computational description and analysis of the spectra of electron binding energies of Al 12 -, Al 13 - and Al 12Ni- clusters, which differ in size and/or composition by a single atom yet possess strikingly different measured photoelectron spectra, is presented. It is shown that the measured spectra can not only be reproduced computationally with quantitative fidelity – this is achieved through a combination of state-of-the-art density functional theory with a highly accurate scheme for conversion of the Kohn-Sham eigenenergies into electron binding energies – but also explained in terms of the effects of size, structure/symmetry and composition. Furthermore,more » a new methodology is developed and applied that provides for disentanglement and differential assignment of the separate roles played by size, structure/symmetry and composition in defining the observed differences in the measured spectra. The methodology is general and applicable to any finite system, homogeneous or heterogeneous. Finally, we project that in combination with advances in synthesis techniques this methodology will become an indispensable computation-based aid in the design of controlled synthesis protocols for manufacture of nanosystems and nanodevices with precisely desired electronic and other characteristics.« less

  4. Effect Sizes for Growth-Modeling Analysis for Controlled Clinical Trials in the Same Metric as for Classical Analysis

    PubMed Central

    Feingold, Alan

    2009-01-01

    The use of growth-modeling analysis (GMA)--including Hierarchical Linear Models, Latent Growth Models, and General Estimating Equations--to evaluate interventions in psychology, psychiatry, and prevention science has grown rapidly over the last decade. However, an effect size associated with the difference between the trajectories of the intervention and control groups that captures the treatment effect is rarely reported. This article first reviews two classes of formulas for effect sizes associated with classical repeated-measures designs that use the standard deviation of either change scores or raw scores for the denominator. It then broadens the scope to subsume GMA, and demonstrates that the independent groups, within-subjects, pretest-posttest control-group, and GMA designs all estimate the same effect size when the standard deviation of raw scores is uniformly used. Finally, it is shown that the correct effect size for treatment efficacy in GMA--the difference between the estimated means of the two groups at end of study (determined from the coefficient for the slope difference and length of study) divided by the baseline standard deviation--is not reported in clinical trials. PMID:19271847

  5. Motion induced interplay effects for VMAT radiotherapy.

    PubMed

    Edvardsson, Anneli; Nordström, Fredrik; Ceberg, Crister; Ceberg, Sofie

    2018-04-19

    The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc therapy (VMAT), to verify the proposed method with measurements, and to use the method to investigate how interplay effects vary with different patient- and machine specific parameters. VMAT treatment plans were created on a virtual phantom in a treatment planning system (TPS). Interplay effects were simulated by dividing each plan into smaller sub-arcs using an in-house developed software and shifting the isocenter for each sub-arc to simulate a sin 6 breathing motion in the superior-inferior direction. The simulations were performed for both flattening-filter (FF) and flattening-filter free (FFF) plans and for different breathing amplitudes, period times, initial breathing phases, dose levels, plan complexities, CTV sizes, and collimator angles. The resulting sub-arcs were calculated in the TPS, generating a dose distribution including the effects of motion. The interplay effects were separated from dose blurring and the relative dose differences to 2% and 98% of the CTV volume (ΔD 98% and ΔD 2% ) were calculated. To verify the simulation method, measurements were carried out, both static and during motion, using a quasi-3D phantom and a motion platform. The results of the verification measurements during motion were comparable to the results of the static measurements. Considerable interplay effects were observed for individual fractions, with the minimum ΔD 98% and maximum ΔD 2% being  -16.7% and 16.2%, respectively. The extent of interplay effects was larger for FFF compared to FF and generally increased for higher breathing amplitudes, larger period times, lower dose levels, and more complex treatment plans. Also, the interplay effects varied considerably with the initial breathing phase, and larger variations were observed for smaller CTV sizes. In conclusion, a method to simulate motion induced interplay effects was developed and verified with measurements, which allowed for a large number of treatment scenarios to be investigated. The simulations showed large interplay effects for individual fractions and that the extent of interplay effects varied with the breathing pattern, FFF/FF, dose level, CTV size, collimator angle, and the complexity of the treatment plan.

  6. Motion induced interplay effects for VMAT radiotherapy

    NASA Astrophysics Data System (ADS)

    Edvardsson, Anneli; Nordström, Fredrik; Ceberg, Crister; Ceberg, Sofie

    2018-04-01

    The purpose of this study was to develop a method to simulate breathing motion induced interplay effects for volumetric modulated arc therapy (VMAT), to verify the proposed method with measurements, and to use the method to investigate how interplay effects vary with different patient- and machine specific parameters. VMAT treatment plans were created on a virtual phantom in a treatment planning system (TPS). Interplay effects were simulated by dividing each plan into smaller sub-arcs using an in-house developed software and shifting the isocenter for each sub-arc to simulate a sin6 breathing motion in the superior–inferior direction. The simulations were performed for both flattening-filter (FF) and flattening-filter free (FFF) plans and for different breathing amplitudes, period times, initial breathing phases, dose levels, plan complexities, CTV sizes, and collimator angles. The resulting sub-arcs were calculated in the TPS, generating a dose distribution including the effects of motion. The interplay effects were separated from dose blurring and the relative dose differences to 2% and 98% of the CTV volume (ΔD98% and ΔD2%) were calculated. To verify the simulation method, measurements were carried out, both static and during motion, using a quasi-3D phantom and a motion platform. The results of the verification measurements during motion were comparable to the results of the static measurements. Considerable interplay effects were observed for individual fractions, with the minimum ΔD98% and maximum ΔD2% being  ‑16.7% and 16.2%, respectively. The extent of interplay effects was larger for FFF compared to FF and generally increased for higher breathing amplitudes, larger period times, lower dose levels, and more complex treatment plans. Also, the interplay effects varied considerably with the initial breathing phase, and larger variations were observed for smaller CTV sizes. In conclusion, a method to simulate motion induced interplay effects was developed and verified with measurements, which allowed for a large number of treatment scenarios to be investigated. The simulations showed large interplay effects for individual fractions and that the extent of interplay effects varied with the breathing pattern, FFF/FF, dose level, CTV size, collimator angle, and the complexity of the treatment plan.

  7. Cognitive effects of two nutraceuticals Ginseng and Bacopa benchmarked against modafinil: a review and comparison of effect sizes.

    PubMed

    Neale, Chris; Camfield, David; Reay, Jonathon; Stough, Con; Scholey, Andrew

    2013-03-01

    Over recent years there has been increasing research into both pharmaceutical and nutraceutical cognition enhancers. Here we aimed to calculate the effect sizes of positive cognitive effect of the pharmaceutical modafinil in order to benchmark the effect of two widely used nutraceuticals Ginseng and Bacopa (which have consistent acute and chronic cognitive effects, respectively). A search strategy was implemented to capture clinical studies into the neurocognitive effects of modafinil, Ginseng and Bacopa. Studies undertaken on healthy human subjects using a double-blind, placebo-controlled design were included. For each study where appropriate data were included, effect sizes (Cohen's d) were calculated for measures showing significant positive and negative effects of treatment over placebo. The highest effect sizes for cognitive outcomes were 0.77 for modafinil (visuospatial memory accuracy), 0.86 for Ginseng (simple reaction time) and 0.95 for Bacopa (delayed word recall). These data confirm that neurocognitive enhancement from well characterized nutraceuticals can produce cognition enhancing effects of similar magnitude to those from pharmaceutical interventions. Future research should compare these effects directly in clinical trials. © 2012 The Authors. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  8. Retrieval of subvisual cirrus cloud optical thickness from limb-scatter measurements

    NASA Astrophysics Data System (ADS)

    Wiensz, J. T.; Degenstein, D. A.; Lloyd, N. D.; Bourassa, A. E.

    2013-01-01

    We present a technique for estimating the optical thickness of subvisual cirrus clouds detected by OSIRIS (Optical Spectrograph and Infrared Imaging System), a limb-viewing satellite instrument that measures scattered radiances from the UV to the near-IR. The measurement set is composed of a ratio of limb radiance profiles at two wavelengths that indicates the presence of cloud-scattering regions. Cross-sections and phase functions from an in situ database are used to simulate scattering by cloud-particles. With appropriate configurations discussed in this paper, the SASKTRAN successive-orders of scatter radiative transfer model is able to simulate accurately the in-cloud radiances from OSIRIS. Configured in this way, the model is used with a multiplicative algebraic reconstruction technique (MART) to retrieve the cloud extinction profile for an assumed effective cloud particle size. The sensitivity of these retrievals to key auxiliary model parameters is shown, and it is shown that the retrieved extinction profile, for an assumed effective cloud particle size, models well the measured in-cloud radiances from OSIRIS. The greatest sensitivity of the retrieved optical thickness is to the effective cloud particle size. Since OSIRIS has an 11-yr record of subvisual cirrus cloud detections, the work described in this manuscript provides a very useful method for providing a long-term global record of the properties of these clouds.

  9. The effects of surfactant and electrolyte concentrations on the size of nanochitosan during storage

    NASA Astrophysics Data System (ADS)

    Primaningtyas, Annisa; Budhijanto, Wiratni; Fahrurrozi, Mohammad; Kusumastuti, Yuni

    2017-05-01

    The nano-sized particle of chitosan (nanochitosan) is a potential natural preservative agent for fresh fish and fish product preservation. Theoretically, nano-sized particles exert strong van der Waals force to each other so that the problem associated with nanochitosan is agglomeration that leads to size instability during storage. Size stability is of importance in the application of nanochitosan as an antimicrobial agent because it considerably affects the antimicrobial activity of chitosan. In this study, the formulation of nanochitosan was optimized with respect to the two major factors in colloid dispersion theory, which were the presence of surfactant and electrolyte. Polysorbate-80 was chosen as the representative of food grade surfactant while NaCl was used as the electrolyte. The purposes of this study were to evaluate the effect of polysorbate-80 concentration and to determine the effect of NaCl ions on the particle size of nanochitosan for at least one month storage period. Data were analyzed using Analysis of Variance (ANOVA) to identify the factors significantly affect the size stability. The dynamics of particle size distribution during storage was measured by Particle Size Analyzer (PSA). The result showed that surfactant did not significantly affect the particle size stability. On the other hand, the addition of electrolyte into the colloidal dispersion of nanochitosan consistently stabilized and also narrowed the particle size distribution during storage in the range of 175-391 nm.

  10. Bias and Precision of Measures of Association for a Fixed-Effect Multivariate Analysis of Variance Model

    ERIC Educational Resources Information Center

    Kim, Soyoung; Olejnik, Stephen

    2005-01-01

    The sampling distributions of five popular measures of association with and without two bias adjusting methods were examined for the single factor fixed-effects multivariate analysis of variance model. The number of groups, sample sizes, number of outcomes, and the strength of association were manipulated. The results indicate that all five…

  11. Reliable individual-level neural markers of high-level language processing: A necessary precursor for relating neural variability to behavioral and genetic variability.

    PubMed

    Mahowald, Kyle; Fedorenko, Evelina

    2016-10-01

    The majority of functional neuroimaging investigations aim to characterize an average human brain. However, another important goal of cognitive neuroscience is to understand the ways in which individuals differ from one another and the significance of these differences. This latter goal is given special weight by the recent reconceptualization of neurological disorders where sharp boundaries are no longer drawn either between health and neuropsychiatric and neurodevelopmental disorders, or among different disorders (e.g., Insel et al., 2010). Consequently, even the variability in the healthy population can inform our understanding of brain disorders. However, because the use of functional neural markers is still in its infancy, no consensus presently exists about which measures (e.g., effect size?, extent of activation?, degree of lateralization?) are the best ones to use. We here attempt to address this question with respect to one large-scale neural system: the set of brain regions in the frontal and temporal cortices that jointly support high-level linguistic processing (e.g., Binder et al., 1997; Fedorenko, Hsieh, Nieto-Castanon, Whitfield-Gabrieli, & Kanwisher, 2010). In particular, using data from 150 individuals all of whom had performed a language "localizer" task contrasting sentences and nonword sequences (Fedorenko et al., 2010), we: a) characterize the distributions of the values for four key neural measures of language activity (region effect sizes, region volumes, lateralization based on effect sizes, and lateralization based on volumes); b) test the reliability of these measures in a subset of 32 individuals who were scanned across two sessions; c) evaluate the relationship among the different regions of the language system; and d) evaluate the relationship among the different neural measures. Based on our results, we provide some recommendations for future studies of brain-behavior and brain-genes relationships. Although some of our conclusions are specific to the language system, others (e.g., the fact that effect-size-based measures tend to be more reliable than volume-based measures) are likely to generalize to the rest of the brain. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Quantifying the Variation in the Effective Population Size Within a Genome

    PubMed Central

    Gossmann, Toni I.; Woolfit, Megan; Eyre-Walker, Adam

    2011-01-01

    The effective population size (Ne) is one of the most fundamental parameters in population genetics. It is thought to vary across the genome as a consequence of differences in the rate of recombination and the density of selected sites due to the processes of genetic hitchhiking and background selection. Although it is known that there is intragenomic variation in the effective population size in some species, it is not known whether this is widespread or how much variation in the effective population size there is. Here, we test whether the effective population size varies across the genome, between protein-coding genes, in 10 eukaryotic species by considering whether there is significant variation in neutral diversity, taking into account differences in the mutation rate between loci by using the divergence between species. In most species we find significant evidence of variation. We investigate whether the variation in Ne is correlated to recombination rate and the density of selected sites in four species, for which these data are available. We find that Ne is positively correlated to recombination rate in one species, Drosophila melanogaster, and negatively correlated to a measure of the density of selected sites in two others, humans and Arabidopsis thaliana. However, much of the variation remains unexplained. We use a hierarchical Bayesian analysis to quantify the amount of variation in the effective population size and show that it is quite modest in all species—most genes have an Ne that is within a few fold of all other genes. Nonetheless we show that this modest variation in Ne is sufficient to cause significant differences in the efficiency of natural selection across the genome, by demonstrating that the ratio of the number of nonsynonymous to synonymous polymorphisms is significantly correlated to synonymous diversity and estimates of Ne, even taking into account the obvious nonindependence between these measures. PMID:21954163

  13. The Effects of Flocculation on the Propagation of Ultrasound in Dilute Kaolin Slurries.

    PubMed

    Austin; Challis

    1998-10-01

    A broadband ultrasonic spectrometer has been used to measure ultrasonic attenuation and phase velocity dispersion as functions of frequency in kaolin suspensions over a range of solid volume fractions from phi = 0.01 to phi = 0.08 and over a pH range from 3 to 9. The Harker and Temple theory was used to simulate ultrasound propagation in the suspension, using measured slope viscosity, particle size, and size distribution. Simulated results for ultrasonic attenuation and phase velocity agree well with measured values. Both sets of results agree well and show that for volume fractions above phi approximately 0.05 attenuation and velocity dispersion increase for increasing floc size, whereas for volume fractions below phi approximately 0.05 attenuation and velocity dispersion both decrease. It is proposed that the mechanism for this change in behavior around phi approximately 0.05 involves changes in floc density and floc size distribution with phi and pH. Copyright 1998 Academic Press.

  14. Measuring droplet size of agriuclutral spray nozzles - Measurement distance and airspeed effects

    USDA-ARS?s Scientific Manuscript database

    With a number of new spray testing laboratories going into operation within the U.S. and each gearing up to measure spray atomization from agricultural spray nozzles using laser diffraction, establishing and following a set of scientific standard procedures is crucial to long term data generation an...

  15. A Phase Field Study of the Effect of Microstructure Grain Size Heterogeneity on Grain Growth

    NASA Astrophysics Data System (ADS)

    Crist, David J. D.

    Recent studies conducted with sharp-interface models suggest a link between the spatial distribution of grain size variance and average grain growth rate. This relationship and its effect on grain growth rate was examined using the diffuse-interface Phase Field Method on a series of microstructures with different degrees of grain size gradation. Results from this work indicate that the average grain growth rate has a positive correlation with the average grain size dispersion for phase field simulations, confirming previous observations. It is also shown that the grain growth rate in microstructures with skewed grain size distributions is better measured through the change in the volume-weighted average grain size than statistical mean grain size. This material is based upon work supported by the National Science Foundation under Grant No. 1334283. The NSF project title is "DMREF: Real Time Control of Grain Growth in Metals" and was awarded by the Civil, Mechanical and Manufacturing Innovation division under the Designing Materials to Revolutionize and Engineer our Future (DMREF) program.

  16. Ultrafine particles and nitrogen oxides generated by gas and electric cooking.

    PubMed

    Dennekamp, M; Howarth, S; Dick, C A; Cherrie, J W; Donaldson, K; Seaton, A

    2001-08-01

    To measure the concentrations of particles less than 100 nm diameter and of oxides of nitrogen generated by cooking with gas and electricity, to comment on possible hazards to health in poorly ventilated kitchens. Experiments with gas and electric rings, grills, and ovens were used to compare different cooking procedures. Nitrogen oxides (NO(x)) were measured by a chemiluminescent ML9841A NO(x) analyser. A TSI 3934 scanning mobility particle sizer was used to measure average number concentration and size distribution of aerosols in the size range 10-500 nm. High concentrations of particles are generated by gas combustion, by frying, and by cooking of fatty foods. Electric rings and grills may also generate particles from their surfaces. In experiments where gas burning was the most important source of particles, most particles were in the size range 15-40 nm. When bacon was fried on the gas or electric rings the particles were of larger diameter, in the size range 50-100 nm. The smaller particles generated during experiments grew in size with time because of coagulation. Substantial concentrations of NO(X) were generated during cooking on gas; four rings for 15 minutes produced 5 minute peaks of about 1000 ppb nitrogen dioxide and about 2000 ppb nitric oxide. Cooking in a poorly ventilated kitchen may give rise to potentially toxic concentrations of numbers of particles. Very high concentrations of oxides of nitrogen may also be generated by gas cooking, and with no extraction and poor ventilation, may reach concentrations at which adverse health effects may be expected. Although respiratory effects of exposure to NO(x) might be anticipated, recent epidemiology suggests that cardiac effects cannot be excluded, and further investigation of this is desirable.

  17. Knowledge and psychosocial effects of the film super size me on young adults.

    PubMed

    Cottone, Ellen; Byrd-Bredbenner, Carol

    2007-07-01

    The prevalence of overweight and obesity has risen dramatically over the past 2 decades. Among the many contributing factors is increased consumption of fast foods. Mass media outlets have cited the potential of the film Super Size Me to alter this behavior. The purpose of this study was to determine the effect of this film on young adults' fast-food knowledge and psychosocial measures (ie, attitudes, self-efficacy, healthy weight locus of control, and stage of change) and evaluate the effectiveness of this film as a form of emotional arousal and consciousness-raising. A pretest-posttest follow-up control group design with random assignment was used. Young adults (n=135; 54% female) completed the pretest; approximately 10 days later viewed a film then completed the posttest; and about 9 days later completed the follow-up test. The experimental group (n=80) viewed Super Size Me. The control group (n=55) viewed an unrelated film. Unpaired t tests revealed that the study groups did not differ significantly (P>0.05) at pretest on any measure. Analysis of covariance, with pretest score as the covariate, revealed the experimental group scored substantially better than the control group at posttest on knowledge and nearly all psychosocial measures. In addition, the experimental group continued to score substantially higher than the control group at follow-up on knowledge, stage of change, and consciousness-raising and lower on external: chance health locus of control. Super Size Me represents a potentially powerful tool for nutrition education. Nutrition practitioners should consider using Super Size Me as a consciousness-raising and emotional arousal change process with patients in pre-action stages of change for reducing fast-food intake.

  18. Water equivalent thickness of immobilization devices in proton therapy planning - Modelling at treatment planning and validation by measurements with a multi-layer ionization chamber.

    PubMed

    Fellin, Francesco; Righetto, Roberto; Fava, Giovanni; Trevisan, Diego; Amelio, Dante; Farace, Paolo

    2017-03-01

    To investigate the range errors made in treatment planning due to the presence of the immobilization devices along the proton beam path. The measured water equivalent thickness (WET) of selected devices was measured by a high-energy spot and a multi-layer ionization chamber and compared with that predicted by treatment planning system (TPS). Two treatment couches, two thermoplastic masks (both un-stretched and stretched) and one headrest were selected. At TPS, every immobilization device was modelled as being part of the patient. The following parameters were assessed: CT acquisition protocol, dose-calculation grid-sizes (1.5 and 3.0mm) and beam-entrance with respect to the devices (coplanar and non-coplanar). Finally, the potential errors produced by a wrong manual separation between treatment couch and the CT table (not present during treatment) were investigated. In the thermoplastic mask, there was a clear effect due to beam entrance, a moderate effect due to the CT protocols and almost no effect due to TPS grid-size, with 1mm errors observed only when thick un-stretched portions were crossed by non-coplanar beams. In the treatment couches the WET errors were negligible (<0.3mm) regardless of the grid-size and CT protocol. The potential range errors produced in the manual separation between treatment couch and CT table were small with 1.5mm grid-size, but could be >0.5mm with a 3.0mm grid-size. In the headrest, WET errors were negligible (0.2mm). With only one exception (un-stretched mask, non-coplanar beams), the WET of all the immobilization devices was properly modelled by the TPS. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  19. HOW LOW CAN YOU GO? THE PHOTOECCENTRIC EFFECT FOR PLANETS OF VARIOUS SIZES

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Price, Ellen M.; Rogers, Leslie A.; Johnson, John Asher

    2015-01-20

    It is well-known that the light curve of a transiting planet contains information about the planet's orbital period and size relative to the host star. More recently, it has been demonstrated that a tight constraint on an individual planet's eccentricity can sometimes be derived from the light curve via the ''photoeccentric effect'', the effect of a planet's eccentricity on the shape and duration of its light curve. This has only been studied for large planets and high signal-to-noise scenarios, raising the question of how well it can be measured for smaller planets or low signal-to-noise cases. We explore the limitsmore » of the photoeccentric effect over a wide range of planet parameters. The method hinges upon measuring g directly from the light curve, where g is the ratio of the planet's speed (projected on the plane of the sky) during transit to the speed expected for a circular orbit. We find that when the signal-to-noise in the measurement of g is <10, the ability to measure eccentricity with the photoeccentric effect decreases. We develop a ''rule of thumb'' that for per-point relative photometric uncertainties σ = (10{sup –3}, 10{sup –4}, 10{sup –5}), the critical values of the planet-star radius ratio are R{sub p} /R {sub *} ≈ (0.1, 0.05, 0.03) for Kepler-like 30 minute integration times. We demonstrate how to predict the best-case uncertainty in eccentricity that can be found with the photoeccentric effect for any light curve. This clears the path to study eccentricities of individual planets of various sizes in the Kepler sample and future transit surveys.« less

  20. Improvements for retrieval of cloud droplet size by the POLDER instrument

    NASA Astrophysics Data System (ADS)

    Shang, H.; Husi, L.; Bréon, F. M.; Ma, R.; Chen, L.; Wang, Z.

    2017-12-01

    The principles of cloud droplet size retrieval via Polarization and Directionality of the Earth's Reflectance (POLDER) requires that clouds be horizontally homogeneous. The retrieval is performed by combining all measurements from an area of 150 km × 150 km to compensate for POLDER's insufficient directional sampling. Using POLDER-like data simulated with the RT3 model, we investigate the impact of cloud horizontal inhomogeneity and directional sampling on the retrieval and analyze which spatial resolution is potentially accessible from the measurements. Case studies show that the sub-grid-scale variability in droplet effective radius (CDR) can significantly reduce valid retrievals and introduce small biases to the CDR ( 1.5µm) and effective variance (EV) estimates. Nevertheless, the sub-grid-scale variations in EV and cloud optical thickness (COT) only influence the EV retrievals and not the CDR estimate. In the directional sampling cases studied, the retrieval using limited observations is accurate and is largely free of random noise. Several improvements have been made to the original POLDER droplet size retrieval. For example, measurements in the primary rainbow region (137-145°) are used to ensure retrievals of large droplet (>15 µm) and to reduce the uncertainties caused by cloud heterogeneity. A premium resoltion of 0.8° is determined by considering successful retrievals and cloud horizontal homogeneity. The improved algorithm is applied to measurements of POLDER in 2008, and we further compared our retrievals with cloud effective radii estimations of Moderate Resolution Imaging Spectroradiometer (MODIS). The results indicate that in global scale, the cloud effective radii and effective variance is larger in the central ocean than inland and coast areas. Over heavy polluted regions, the cloud droplets has small effective radii and narraw distribution due to the influence of aerosol particles.

  1. Interventions to Improve Medication Adherence in Hypertensive Patients: Systematic Review and Meta-analysis.

    PubMed

    Conn, Vicki S; Ruppar, Todd M; Chase, Jo-Ana D; Enriquez, Maithe; Cooper, Pamela S

    2015-12-01

    This systematic review applied meta-analytic procedures to synthesize medication adherence interventions that focus on adults with hypertension. Comprehensive searching located trials with medication adherence behavior outcomes. Study sample, design, intervention characteristics, and outcomes were coded. Random-effects models were used in calculating standardized mean difference effect sizes. Moderator analyses were conducted using meta-analytic analogues of ANOVA and regression to explore associations between effect sizes and sample, design, and intervention characteristics. Effect sizes were calculated for 112 eligible treatment-vs.-control group outcome comparisons of 34,272 subjects. The overall standardized mean difference effect size between treatment and control subjects was 0.300. Exploratory moderator analyses revealed interventions were most effective among female, older, and moderate- or high-income participants. The most promising intervention components were those linking adherence behavior with habits, giving adherence feedback to patients, self-monitoring of blood pressure, using pill boxes and other special packaging, and motivational interviewing. The most effective interventions employed multiple components and were delivered over many days. Future research should strive for minimizing risks of bias common in this literature, especially avoiding self-report adherence measures.

  2. Effect of analgesic therapy on clinical outcome measures in a randomized controlled trial using client-owned dogs with hip osteoarthritis.

    PubMed

    Malek, Sarah; Sample, Susannah J; Schwartz, Zeev; Nemke, Brett; Jacobson, Peer B; Cozzi, Elizabeth M; Schaefer, Susan L; Bleedorn, Jason A; Holzman, Gerianne; Muir, Peter

    2012-10-04

    Pain and impaired mobility because of osteoarthritis (OA) is common in dogs and humans. Efficacy studies of analgesic drug treatment of dogs with naturally occurring OA may be challenging, as a caregiver placebo effect is typically evident. However, little is known about effect sizes of common outcome-measures in canine clinical trials evaluating treatment of OA pain. Forty-nine client-owned dogs with hip OA were enrolled in a randomized, double-blinded placebo-controlled prospective trial. After a 1 week baseline period, dogs were randomly assigned to a treatment (ABT-116 - transient receptor potential vanilloid 1 (TRPV1) antagonist, Carprofen - non-steroidal anti-inflammatory drug (NSAID), Tramadol - synthetic opiate, or Placebo) for 2 weeks. Outcome-measures included physical examination parameters, owner questionnaire, activity monitoring, gait analysis, and use of rescue medication. Acute hyperthermia developed after ABT-116 treatment (P < 0.001). Treatment with carprofen (P ≤ 0.01) and tramadol (P ≤ 0.001) led to improved mobility assessed by owner questionnaire. Nighttime activity was increased after ABT-116 treatment (P = 0.01). Kinetic gait analysis did not reveal significant treatment effects. Use of rescue treatment decreased with treatment in the ABT-116 and Carprofen groups (P < 0.001). Questionnaire score and activity count at the end of treatment were correlated with age, clinical severity at trial entry, and outcome measure baseline status (SR ≥ ±0.40, P ≤ 0.005). Placebo treatment effects were evident with all variables studied. Treatment of hip OA in client-owned dogs is associated with a placebo effect for all variables that are commonly used for efficacy studies of analgesic drugs. This likely reflects caregiver bias or the phenomenon of regression to the mean. In the present study, outcome measures with significant effects also varied between groups, highlighting the value of using multiple outcome measures, as well as an a priori analysis of effect size associated with each measure. Effect size data from the present study could be used to inform design of future trials studying analgesic treatment of canine OA. Our results suggest that analgesic treatment with ABT-116 is not as effective as carprofen or tramadol for treatment of hip arthritis pain in client-owned dogs.

  3. Effect of analgesic therapy on clinical outcome measures in a randomized controlled trial using client-owned dogs with hip osteoarthritis

    PubMed Central

    2012-01-01

    Background Pain and impaired mobility because of osteoarthritis (OA) is common in dogs and humans. Efficacy studies of analgesic drug treatment of dogs with naturally occurring OA may be challenging, as a caregiver placebo effect is typically evident. However, little is known about effect sizes of common outcome-measures in canine clinical trials evaluating treatment of OA pain. Forty-nine client-owned dogs with hip OA were enrolled in a randomized, double-blinded placebo-controlled prospective trial. After a 1 week baseline period, dogs were randomly assigned to a treatment (ABT-116 – transient receptor potential vanilloid 1 (TRPV1) antagonist, Carprofen – non-steroidal anti-inflammatory drug (NSAID), Tramadol - synthetic opiate, or Placebo) for 2 weeks. Outcome-measures included physical examination parameters, owner questionnaire, activity monitoring, gait analysis, and use of rescue medication. Results Acute hyperthermia developed after ABT-116 treatment (P < 0.001). Treatment with carprofen (P ≤ 0.01) and tramadol (P ≤ 0.001) led to improved mobility assessed by owner questionnaire. Nighttime activity was increased after ABT-116 treatment (P = 0.01). Kinetic gait analysis did not reveal significant treatment effects. Use of rescue treatment decreased with treatment in the ABT-116 and Carprofen groups (P < 0.001). Questionnaire score and activity count at the end of treatment were correlated with age, clinical severity at trial entry, and outcome measure baseline status (SR ≥ ±0.40, P ≤ 0.005). Placebo treatment effects were evident with all variables studied. Conclusion Treatment of hip OA in client-owned dogs is associated with a placebo effect for all variables that are commonly used for efficacy studies of analgesic drugs. This likely reflects caregiver bias or the phenomenon of regression to the mean. In the present study, outcome measures with significant effects also varied between groups, highlighting the value of using multiple outcome measures, as well as an a priori analysis of effect size associated with each measure. Effect size data from the present study could be used to inform design of future trials studying analgesic treatment of canine OA. Our results suggest that analgesic treatment with ABT-116 is not as effective as carprofen or tramadol for treatment of hip arthritis pain in client-owned dogs. PMID:23035739

  4. Does the rising placebo response impact antihypertensive clinical trial outcomes? An analysis of data from the Food and Drug Administration 1990-2016

    PubMed Central

    Fahl Mar, Kaysee; Schilling, Joshua; Brown, Walter A.

    2018-01-01

    Background Recent studies show that placebo response has grown significantly over time in clinical trials for antidepressants, ADHD medications, antiepileptics, and antidiabetics. Contrary to expectations, trial outcome measures and success rates have not been impacted. This study aimed to see if this trend of increasing placebo response and stable efficacy outcome measures is unique to the conditions previously studied or if it occurs in trials for conditions with physiologically-measured symptoms, such as hypertension. Method For this reason, we evaluated the efficacy data reported in the US Food and Drug Administration Medical and Statistical reviews for 23 antihypertensive programs (32,022 patients, 63 trials, 142 treatment arms). Placebo and medication response, effect sizes, and drug-placebo differences were calculated for each treatment arm and examined over time using meta-regression. We also explored the relationship of sample size, trial duration, baseline blood pressure, and number of treatment arms to placebo/drug response and efficacy outcome measures. Results Like trials of other conditions, placebo response has risen significantly over time (R2 = 0.093, p = 0.018) and effect size (R2 = 0.013, p = 0.187) drug-placebo difference (R2 = 0.013, p = 0.182) and success rate (134/142, 94.4%) have remained unaffected, likely due to a significant compensatory increase in antihypertensive response (R2 = 0.086, p<0.001). Treatment arms are likely overpowered with sample sizes increasing over time (R2 = 0.387, p<0.0001) and stable, large effect sizes (0.78 ±0.37). The exploratory analysis of sample size, trial duration, baseline blood pressure, and number of treatment arms yielded mixed results unlikely to explain the pattern of placebo response and efficacy outcomes over time. The magnitude of placebo response had no relationship to effect size (p = 0.877), antihypertensive-placebo differences (p = 0.752), or p-values (p = 0.963) but was correlated with antihypertensive response (R2 = 0.347, p<0.0001). Conclusions As hypothesized, this study shows that placebo response is increasing in clinical trials for hypertension without any evidence of this increase impacting trial outcomes. Attempting to control placebo response in clinical trials for hypertension may not be necessary for successful efficacy outcomes. In exploratory analysis, we noted that despite finding significant relationships, none of the trial or patient characteristics we examined offered a clear explanation of the rise in placebo and stability in outcome measures over time. Collectively, these data suggest that the phenomenon of increasing placebo response and stable efficacy outcomes may be a general trend, occurring across trials for various psychiatric and medical conditions with physiological and non-physiological endpoints. PMID:29489874

  5. Safe and sensible preprocessing and baseline correction of pupil-size data.

    PubMed

    Mathôt, Sebastiaan; Fabius, Jasper; Van Heusden, Elle; Van der Stigchel, Stefan

    2018-02-01

    Measurement of pupil size (pupillometry) has recently gained renewed interest from psychologists, but there is little agreement on how pupil-size data is best analyzed. Here we focus on one aspect of pupillometric analyses: baseline correction, i.e., analyzing changes in pupil size relative to a baseline period. Baseline correction is useful in experiments that investigate the effect of some experimental manipulation on pupil size. In such experiments, baseline correction improves statistical power by taking into account random fluctuations in pupil size over time. However, we show that baseline correction can also distort data if unrealistically small pupil sizes are recorded during the baseline period, which can easily occur due to eye blinks, data loss, or other distortions. Divisive baseline correction (corrected pupil size = pupil size/baseline) is affected more strongly by such distortions than subtractive baseline correction (corrected pupil size = pupil size - baseline). We discuss the role of baseline correction as a part of preprocessing of pupillometric data, and make five recommendations: (1) before baseline correction, perform data preprocessing to mark missing and invalid data, but assume that some distortions will remain in the data; (2) use subtractive baseline correction; (3) visually compare your corrected and uncorrected data; (4) be wary of pupil-size effects that emerge faster than the latency of the pupillary response allows (within ±220 ms after the manipulation that induces the effect); and (5) remove trials on which baseline pupil size is unrealistically small (indicative of blinks and other distortions).

  6. L2 Reading Comprehension and Its Correlates: A Meta-Analysis

    ERIC Educational Resources Information Center

    Jeon, Eun Hee; Yamashita, Junko

    2014-01-01

    The present meta-analysis examined the overall average correlation (weighted for sample size and corrected for measurement error) between passage-level second language (L2) reading comprehension and 10 key reading component variables investigated in the research domain. Four high-evidence correlates (with 18 or more accumulated effect sizes: L2…

  7. Second Language Vocabulary Growth at Advanced Level

    ERIC Educational Resources Information Center

    Ozturk, Meral

    2016-01-01

    This study investigated the receptive vocabulary growth of advanced EFL learners in an English-medium degree programme. The study used the Vocabulary Size Test in a cross-sectional design to measure the vocabulary size of learners at various stages of study. The effect of word frequency on vocabulary development and the presence of an…

  8. Power and Precision in Confirmatory Factor Analytic Tests of Measurement Invariance

    ERIC Educational Resources Information Center

    Meade, Adam W.; Bauer, Daniel J.

    2007-01-01

    This study investigates the effects of sample size, factor overdetermination, and communality on the precision of factor loading estimates and the power of the likelihood ratio test of factorial invariance in multigroup confirmatory factor analysis. Although sample sizes are typically thought to be the primary determinant of precision and power,…

  9. Estimating Standardized Linear Contrasts of Means with Desired Precision

    ERIC Educational Resources Information Center

    Bonett, Douglas G.

    2009-01-01

    L. Wilkinson and the Task Force on Statistical Inference (1999) recommended reporting confidence intervals for measures of effect sizes. If the sample size is too small, the confidence interval may be too wide to provide meaningful information. Recently, K. Kelley and J. R. Rausch (2006) used an iterative approach to computer-generate tables of…

  10. UNIVERSAL RELATIONSHIP OF TOTAL LUNG DEPOSITION OF PARTICLES IN NORMAL ADULTS WITH PARTICLE SIZE AND BREATHING PATTERN

    EPA Science Inventory

    Particulate matter in the air is known for causing adverse health effects and yet estimating lung deposition dose is difficult because exposure conditions vary widely. We measured total deposition fraction (TDF) of monodisperse aerosols in the size range of 0.04 - 5 micron in dia...

  11. Measurement of surface water runoff from plots of two different sizes

    NASA Astrophysics Data System (ADS)

    Joel, Abraham; Messing, Ingmar; Seguel, Oscar; Casanova, Manuel

    2002-05-01

    Intensities and amounts of water infiltration and runoff on sloping land are governed by the rainfall pattern and soil hydraulic conductivity, as well as by the microtopography and soil surface conditions. These components are closely interrelated and occur simultaneously, and their particular contribution may change during a rainfall event, or their effects may vary at different field scales. The scale effect on the process of infiltration/runoff was studied under natural field and rainfall conditions for two plot sizes: small plots of 0·25 m2 and large plots of 50 m2. The measurements were carried out in the central region of Chile in a piedmont most recently used as natural pastureland. Three blocks, each having one large plot and five small plots, were established. Cumulative rainfall and runoff quantities were sampled every 5 min. Significant variations in runoff responses to rainfall rates were found for the two plot sizes. On average, large plots yielded only 40% of runoff quantities produced on small plots per unit area. This difference between plot sizes was observed even during periods of continuous runoff.

  12. Anthropometric study with emphasis on hand and foot measurements in the Prader-Willi syndrome: sex, age and chromosome effects.

    PubMed

    Butler, M G; Haynes, J L; Meaney, F J

    1991-01-01

    Age, sex and chromosome effects on weight, height, sitting height, three head dimensions, and five hand and three foot measurements were analyzed from 57 patients (35 males and 22 females) with the Prader-Willi syndrome (PWS). No significant differences were observed in anthropometric data between PWS patients with the 15q chromosome deletion and those with normal chromosomes. Preschool children were found to have dolichocephaly, while hand and foot measurements, stature and sitting height were within normal range, although foot size was smaller than hand size in females when compared with PWS males. However, anthropometric measurements, excluding weight, head length and ankle breadth, were less than -2 SD in adult patients. Abnormal growth patterns apparently exist with significant negative correlations with age, particularly in PWS males, for height, sitting height, head circumference, and hand and foot measurements, but a significant positive correlation for weight was found in patients below 10 years of age.

  13. True external diameter better predicts hemodynamic performance of bioprosthetic aortic valves than the manufacturers' stated size.

    PubMed

    Cevasco, Marisa; Mick, Stephanie L; Kwon, Michael; Lee, Lawrence S; Chen, Edward P; Chen, Frederick Y

    2013-05-01

    Currently, there is no universal standard for sizing bioprosthetic aortic valves. Hence, a standardized comparison was performed to clarify this issue. Every size of four commercially available bioprosthetic aortic valves marketed in the United States (Biocor Supra; Mosaic Ultra; Magna Ease; Mitroflow) was obtained. Subsequently, custom sizers were created that were accurate to 0.0025 mm to represent aortic roots 18 mm through 32 mm, and these were used to measure the external diameter of each valve. Using the effective orifice area (EOA) and transvalvular pressure gradient (TPG) data submitted to the FDA, a comparison was made between the hemodynamic properties of valves with equivalent manufacturer stated sizes and valves with equivalent measured external diameters. Based on manufacturer size alone, the valves at first seemed to be hemodynamically different from each other, with Mitroflow valves appearing to be hemodynamically superior, having a large EOA and equivalent or superior TPG (p < 0.05). However, Mitroflow valves had a larger measured external diameter than the other valves of a given numerical manufacturer size. Valves with equivalent external diameters were then compared, regardless of the stated manufacturer sizes. For truly equivalently sized valves (i.e., by measured external diameter) there was no clear hemodynamic difference. There was no statistical difference in the EOAs between the Biocor Supra, Mosaic Ultra, and Mitroflow valves, and the Magna Ease valve had a statistically smaller EOA (p < 0.05). On comparing the mean TPG, the Biocor Supra and Mitroflow valves had statistically equivalent gradients to each other, as did the Mosaic Ultra and Magna Ease valves. When comparing valves of the same numerical manufacturer size, there appears to be a difference in hemodynamic performance across different manufacturers' valves according to FDA data. However, comparing equivalently measured valves eliminates the differences between valves produced by different manufacturers.

  14. Size-dependent bending modulus of nanotubes induced by the imperfect boundary conditions

    PubMed Central

    Zhang, Jin

    2016-01-01

    The size-dependent bending modulus of nanotubes, which was widely observed in most existing three-point bending experiments [e.g., J. Phys. Chem. B 117, 4618–4625 (2013)], has been tacitly assumed to originate from the shear effect. In this paper, taking boron nitride nanotubes as an example, we directly measured the shear effect by molecular dynamics (MD) simulations and found that the shear effect is not the major factor responsible for the observed size-dependent bending modulus of nanotubes. To further explain the size-dependence phenomenon, we abandoned the assumption of perfect boundary conditions (BCs) utilized in the aforementioned experiments and studied the influence of the BCs on the bending modulus of nanotubes based on MD simulations. The results show that the imperfect BCs also make the bending modulus of nanotubes size-dependent. Moreover, the size-dependence phenomenon induced by the imperfect BCs is much more significant than that induced by the shear effect, which suggests that the imperfect BC is a possible physical origin that leads to the strong size-dependence of the bending modulus found in the aforementioned experiments. To capture the physics behind the MD simulation results, a beam model with the general BCs is proposed and found to fit the experimental data very well. PMID:27941866

  15. The Effects of Size and Type of Vocal Fold Polyp on Some Acoustic Voice Parameters.

    PubMed

    Akbari, Elaheh; Seifpanahi, Sadegh; Ghorbani, Ali; Izadi, Farzad; Torabinezhad, Farhad

    2018-03-01

    Vocal abuse and misuse would result in vocal fold polyp. Certain features define the extent of vocal folds polyp effects on voice acoustic parameters. The present study aimed to define the effects of polyp size on acoustic voice parameters, and compare these parameters in hemorrhagic and non-hemorrhagic polyps. In the present retrospective study, 28 individuals with hemorrhagic or non-hemorrhagic polyps of the true vocal folds were recruited to investigate acoustic voice parameters of vowel/ æ/ computed by the Praat software. The data were analyzed using the SPSS software, version 17.0. According to the type and size of polyps, mean acoustic differences and correlations were analyzed by the statistical t test and Pearson correlation test, respectively; with significance level below 0.05. The results indicated that jitter and the harmonics-to-noise ratio had a significant positive and negative correlation with the polyp size (P=0.01), respectively. In addition, both mentioned parameters were significantly different between the two types of the investigated polyps. Both the type and size of polyps have effects on acoustic voice characteristics. In the present study, a novel method to measure polyp size was introduced. Further confirmation of this method as a tool to compare polyp sizes requires additional investigations.

  16. The Effects of Size and Type of Vocal Fold Polyp on Some Acoustic Voice Parameters

    PubMed Central

    Akbari, Elaheh; Seifpanahi, Sadegh; Ghorbani, Ali; Izadi, Farzad; Torabinezhad, Farhad

    2018-01-01

    Background Vocal abuse and misuse would result in vocal fold polyp. Certain features define the extent of vocal folds polyp effects on voice acoustic parameters. The present study aimed to define the effects of polyp size on acoustic voice parameters, and compare these parameters in hemorrhagic and non-hemorrhagic polyps. Methods In the present retrospective study, 28 individuals with hemorrhagic or non-hemorrhagic polyps of the true vocal folds were recruited to investigate acoustic voice parameters of vowel/ æ/ computed by the Praat software. The data were analyzed using the SPSS software, version 17.0. According to the type and size of polyps, mean acoustic differences and correlations were analyzed by the statistical t test and Pearson correlation test, respectively; with significance level below 0.05. Results The results indicated that jitter and the harmonics-to-noise ratio had a significant positive and negative correlation with the polyp size (P=0.01), respectively. In addition, both mentioned parameters were significantly different between the two types of the investigated polyps. Conclusion Both the type and size of polyps have effects on acoustic voice characteristics. In the present study, a novel method to measure polyp size was introduced. Further confirmation of this method as a tool to compare polyp sizes requires additional investigations. PMID:29749984

  17. Online alcohol interventions: a systematic review.

    PubMed

    White, Angela; Kavanagh, David; Stallman, Helen; Klein, Britt; Kay-Lambkin, Frances; Proudfoot, Judy; Drennan, Judy; Connor, Jason; Baker, Amanda; Hines, Emily; Young, Ross

    2010-12-19

    There has been a significant increase in the availability of online programs for alcohol problems. A systematic review of the research evidence underpinning these programs is timely. Our objective was to review the efficacy of online interventions for alcohol misuse. Systematic searches of Medline, PsycINFO, Web of Science, and Scopus were conducted for English abstracts (excluding dissertations) published from 1998 onward. Search terms were: (1) Internet, Web*; (2) online, computer*; (3) alcohol*; and (4) E\\effect*, trial*, random* (where * denotes a wildcard). Forward and backward searches from identified papers were also conducted. Articles were included if (1) the primary intervention was delivered and accessed via the Internet, (2) the intervention focused on moderating or stopping alcohol consumption, and (3) the study was a randomized controlled trial of an alcohol-related screen, assessment, or intervention. The literature search initially yielded 31 randomized controlled trials (RCTs), 17 of which met inclusion criteria. Of these 17 studies, 12 (70.6%) were conducted with university students, and 11 (64.7%) specifically focused on at-risk, heavy, or binge drinkers. Sample sizes ranged from 40 to 3216 (median 261), with 12 (70.6%) studies predominantly involving brief personalized feedback interventions. Using published data, effect sizes could be extracted from 8 of the 17 studies. In relation to alcohol units per week or month and based on 5 RCTs where a measure of alcohol units per week or month could be extracted, differential effect sizes to posttreatment ranged from 0.02 to 0.81 (mean 0.42, median 0.54). Pre-post effect sizes for brief personalized feedback interventions ranged from 0.02 to 0.81, and in 2 multi-session modularized interventions, a pre-post effect size of 0.56 was obtained in both. Pre-post differential effect sizes for peak blood alcohol concentrations (BAC) ranged from 0.22 to 0.88, with a mean effect size of 0.66. The available evidence suggests that users can benefit from online alcohol interventions and that this approach could be particularly useful for groups less likely to access traditional alcohol-related services, such as women, young people, and at-risk users. However, caution should be exercised given the limited number of studies allowing extraction of effect sizes, the heterogeneity of outcome measures and follow-up periods, and the large proportion of student-based studies. More extensive RCTs in community samples are required to better understand the efficacy of specific online alcohol approaches, program dosage, the additive effect of telephone or face-to-face interventions, and effective strategies for their dissemination and marketing.

  18. Online Alcohol Interventions: A Systematic Review

    PubMed Central

    Kavanagh, David; Stallman, Helen; Klein, Britt; Kay-Lambkin, Frances; Proudfoot, Judy; Drennan, Judy; Connor, Jason; Baker, Amanda; Hines, Emily; Young, Ross

    2010-01-01

    Background There has been a significant increase in the availability of online programs for alcohol problems. A systematic review of the research evidence underpinning these programs is timely. Objectives Our objective was to review the efficacy of online interventions for alcohol misuse. Systematic searches of Medline, PsycINFO, Web of Science, and Scopus were conducted for English abstracts (excluding dissertations) published from 1998 onward. Search terms were: (1) Internet, Web*; (2) online, computer*; (3) alcohol*; and (4) E\\effect*, trial*, random* (where * denotes a wildcard). Forward and backward searches from identified papers were also conducted. Articles were included if (1) the primary intervention was delivered and accessed via the Internet, (2) the intervention focused on moderating or stopping alcohol consumption, and (3) the study was a randomized controlled trial of an alcohol-related screen, assessment, or intervention. Results The literature search initially yielded 31 randomized controlled trials (RCTs), 17 of which met inclusion criteria. Of these 17 studies, 12 (70.6%) were conducted with university students, and 11 (64.7%) specifically focused on at-risk, heavy, or binge drinkers. Sample sizes ranged from 40 to 3216 (median 261), with 12 (70.6%) studies predominantly involving brief personalized feedback interventions. Using published data, effect sizes could be extracted from 8 of the 17 studies. In relation to alcohol units per week or month and based on 5 RCTs where a measure of alcohol units per week or month could be extracted, differential effect sizes to posttreatment ranged from 0.02 to 0.81 (mean 0.42, median 0.54). Pre-post effect sizes for brief personalized feedback interventions ranged from 0.02 to 0.81, and in 2 multi-session modularized interventions, a pre-post effect size of 0.56 was obtained in both. Pre-post differential effect sizes for peak blood alcohol concentrations (BAC) ranged from 0.22 to 0.88, with a mean effect size of 0.66. Conclusions The available evidence suggests that users can benefit from online alcohol interventions and that this approach could be particularly useful for groups less likely to access traditional alcohol-related services, such as women, young people, and at-risk users. However, caution should be exercised given the limited number of studies allowing extraction of effect sizes, the heterogeneity of outcome measures and follow-up periods, and the large proportion of student-based studies. More extensive RCTs in community samples are required to better understand the efficacy of specific online alcohol approaches, program dosage, the additive effect of telephone or face-to-face interventions, and effective strategies for their dissemination and marketing. PMID:21169175

  19. New developments on size-dependent growth applied to the crystallization of sucrose

    NASA Astrophysics Data System (ADS)

    Martins, P. M.; Rocha, F.

    2007-12-01

    The effect of crystal size on the growth rate of sucrose (C 12H 22O 11) at 40 °C is investigated from a theoretical and an experimental point of view. Based on new perspectives resulting from the recently introduced spiral nucleation model [P.M. Martins, F. Rocha, Surf. Sci. 601 (2007) 3400], crystal growth rates are expressed in terms of mass deposition per time and crystal volume units. This alternative definition is demonstrated to be size-independent over the considered supersaturation range. The conventional overall growth rate expressed per surface area units is found to be linearly dependent on crystal size. The advantages of the "volumetric" growth rate concept are discussed. Sucrose dissolution rates were measured under reciprocal conditions of the growth experiments in order to investigate the two-way effect of crystal size on mass transfer rates and on the integration kinetics. Both effects are adequately described by combining a well-established diffusion-integration model and the spiral nucleation mechanism.

  20. Erosive Augmentation of Solid Propellant Burning Rate: Motor Size Scaling Effect

    NASA Technical Reports Server (NTRS)

    Strand, L. D.; Cohen, Norman S.

    1990-01-01

    Two different independent variable forms, a difference form and a ratio form, were investigated for correlating the normalized magnitude of the measured erosive burning rate augmentation above the threshold in terms of the amount that the driving parameter (mass flux or Reynolds number) exceeds the threshold value for erosive augmentation at the test condition. The latter was calculated from the previously determined threshold correlation. Either variable form provided a correlation for each of the two motor size data bases individually. However, the data showed a motor size effect, supporting the general observation that the magnitude of erosive burning rate augmentation is reduced for larger rocket motors. For both independent variable forms, the required motor size scaling was attained by including the motor port radius raised to a power in the independent parameter. A boundary layer theory analysis confirmed the experimental finding, but showed that the magnitude of the scale effect is itself dependent upon scale, tending to diminish with increasing motor size.

  1. Effective method of measuring the radioactivity of [ 131I]‐capsule prior to radioiodine therapy with significant reduction of the radiation exposure to the medical staff

    PubMed Central

    Lützen, Ulf; Zhao, Yi; Marx, Marlies; Imme, Thea; Assam, Isong; Siebert, Frank‐Andre; Culman, Juraj

    2016-01-01

    Radiation Protection in Radiology, Nuclear Medicine and Radio Oncology is of the utmost importance. Radioiodine therapy is a frequently used and effective method for the treatment of thyroid disease. Prior to each therapy the radioactivity of the [ 131I]‐capsule must be determined to prevent misadministration. This leads to a significant radiation exposure to the staff. We describe an alternative method, allowing a considerable reduction of the radiation exposure. Two [ 131I]‐capsules (A01=2818.5; A02=73.55.0 MBq) were measured multiple times in their own delivery lead containers — that is to say, [ 131I]‐capsules remain inside the containers during the measurements (shielded measurement) using a dose calibrator and a well‐type and a thyroid uptake probe. The results of the shielded measurements were correlated linearly with the [ 131I]‐capsules radioactivity to create calibration curves for the used devices. Additional radioactivity measurements of 50 [ 131I]‐capsules of different radioactivities were done to validate the shielded measuring method. The personal skin dose rate (HP(0.07)) was determined using calibrated thermo luminescent dosimeters. The determination coefficients for the calibration curves were R2>0.9980 for all devices. The relative uncertainty of the shielded measurement was <6.8%. At a distance of 10 cm from the unshielded capsule the HP(0.07) was 46.18 μSv/(GBq⋅s), and on the surface of the lead container containing the [ 131I]‐capsule the HP(0.07) was 2.99 and 0.27 μSv/(GBq⋅s) for the two used container sizes. The calculated reduction of the effective dose by using the shielded measuring method was, depending on the used container size, 74.0% and 97.4%, compared to the measurement of the unshielded [ 131I]‐capsule using a dose calibrator. The measured reduction of the effective radiation dose in the practice was 56.6% and 94.9 for size I and size II containers. The shielded [ 131I]‐capsule measurement reduces the radiation exposure to the staff significantly and offers the same accuracy of the unshielded measurement in the same amount of time. In order to maintain the consistency of the measuring method, monthly tests have to be done by measuring a [ 131I]‐capsule with known radioactivity. PACS number(s): 93.85.Np, 92.20.Td, 87.50.yk, 87.53.Bn PMID:27455475

  2. Ratio of Cut Surface Area to Leaf Sample Volume for Water Potential Measurements by Thermocouple Psychrometers

    PubMed Central

    Walker, Sue; Oosterhuis, Derrick M.; Wiebe, Herman H.

    1984-01-01

    Evaporative losses from the cut edge of leaf samples are of considerable importance in measurements of leaf water potential using thermocouple psychrometers. The ratio of cut surface area to leaf sample volume (area to volume ratio) has been used to give an estimate of possible effects of evaporative loss in relation to sample size. A wide range of sample sizes with different area to volume ratios has been used. Our results using Glycine max L. Merr. cv Bragg indicate that leaf samples with area to volume values less than 0.2 square millimeter per cubic millimeter give psychrometric leaf water potential measurements that compare favorably with pressure chamber measurements. PMID:16663578

  3. Size effects on negative thermal expansion in cubic ScF{sub 3}

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, C.; Guo, X. G.; Zhang, K.

    2016-07-11

    Scandium trifluoride (ScF{sub 3}), adopting a cubic ReO{sub 3}-type structure at ambient pressure, undergoes a pronounced negative thermal expansion (NTE) over a wide range of temperatures (10 K–1100 K). Here, we report the size effects on the NTE properties of ScF{sub 3}. The magnitude of NTE is reduced with diminishing the crystal size. As revealed by the specific heat measurement, the low-energy phonon vibrations which account for the NTE behavior are stiffened as the crystal size decreases. With decreasing the crystal size, the peaks in high-energy X-ray pair distribution function (PDF) become broad, which cannot be illuminated by local symmetry breaking. Instead,more » the broadened PDF peaks are strongly indicative of enhanced atomic displacements which are suggested to be responsible for the stiffening of NTE-related lattice vibrations. The present study suggests that the NTE properties of ReO{sub 3}-type and other open-framework materials can be effectively adjusted by controlling the crystal size.« less

  4. Nano-sized graphene flakes: insights from experimental synthesis and first principles calculations.

    PubMed

    Lin, Pin-Chun; Chen, Yi-Rui; Hsu, Kuei-Ting; Lin, Tzu-Neng; Tung, Kuo-Lun; Shen, Ji-Lin; Liu, Wei-Ren

    2017-03-01

    In this study, we proposed a cost-effective method for preparing graphene nano-flakes (GNFs) derived from carbon nanotubes (CNTs) via three steps (pressing, homogenization and sonication exfoliation processes). Scanning electron microscopy (SEM), transmission electron microscopy (TEM), atomic force microscopy (AFM), laser scattering, as well as ultraviolet-visible and photoluminescence (PL) measurements were carried out. The results indicated that the size of as-synthesized GNFs was approximately 40-50 nm. Furthermore, we also used first principles calculations to understand the transformation from CNTs to GNFs from the viewpoints of the edge formation energies of GNFs in different shapes and sizes. The corresponding photoluminescence measurements of GNFs were carried out in this work.

  5. Consomic mouse strain selection based on effect size measurement, statistical significance testing and integrated behavioral z-scoring: focus on anxiety-related behavior and locomotion.

    PubMed

    Labots, M; Laarakker, M C; Ohl, F; van Lith, H A

    2016-06-29

    Selecting chromosome substitution strains (CSSs, also called consomic strains/lines) used in the search for quantitative trait loci (QTLs) consistently requires the identification of the respective phenotypic trait of interest and is simply based on a significant difference between a consomic and host strain. However, statistical significance as represented by P values does not necessarily predicate practical importance. We therefore propose a method that pays attention to both the statistical significance and the actual size of the observed effect. The present paper extends on this approach and describes in more detail the use of effect size measures (Cohen's d, partial eta squared - η p (2) ) together with the P value as statistical selection parameters for the chromosomal assignment of QTLs influencing anxiety-related behavior and locomotion in laboratory mice. The effect size measures were based on integrated behavioral z-scoring and were calculated in three experiments: (A) a complete consomic male mouse panel with A/J as the donor strain and C57BL/6J as the host strain. This panel, including host and donor strains, was analyzed in the modified Hole Board (mHB). The consomic line with chromosome 19 from A/J (CSS-19A) was selected since it showed increased anxiety-related behavior, but similar locomotion compared to its host. (B) Following experiment A, female CSS-19A mice were compared with their C57BL/6J counterparts; however no significant differences and effect sizes close to zero were found. (C) A different consomic mouse strain (CSS-19PWD), with chromosome 19 from PWD/PhJ transferred on the genetic background of C57BL/6J, was compared with its host strain. Here, in contrast with CSS-19A, there was a decreased overall anxiety in CSS-19PWD compared to C57BL/6J males, but not locomotion. This new method shows an improved way to identify CSSs for QTL analysis for anxiety-related behavior using a combination of statistical significance testing and effect sizes. In addition, an intercross between CSS-19A and CSS-19PWD may be of interest for future studies on the genetic background of anxiety-related behavior.

  6. Scale-dependent effect sizes of ecological drivers on biodiversity: why standardised sampling is not enough.

    PubMed

    Chase, Jonathan M; Knight, Tiffany M

    2013-05-01

    There is little consensus about how natural (e.g. productivity, disturbance) and anthropogenic (e.g. invasive species, habitat destruction) ecological drivers influence biodiversity. Here, we show that when sampling is standardised by area (species density) or individuals (rarefied species richness), the measured effect sizes depend critically on the spatial grain and extent of sampling, as well as the size of the species pool. This compromises comparisons of effects sizes within studies using standard statistics, as well as among studies using meta-analysis. To derive an unambiguous effect size, we advocate that comparisons need to be made on a scale-independent metric, such as Hurlbert's Probability of Interspecific Encounter. Analyses of this metric can be used to disentangle the relative influence of changes in the absolute and relative abundances of individuals, as well as their intraspecific aggregations, in driving differences in biodiversity among communities. This and related approaches are necessary to achieve generality in understanding how biodiversity responds to ecological drivers and will necessitate a change in the way many ecologists collect and analyse their data. © 2013 John Wiley & Sons Ltd/CNRS.

  7. A Case Study of Ship Track Formation in a Polluted Marine Boundary Layer.

    NASA Astrophysics Data System (ADS)

    Noone, Kevin J.; Johnson, Doug W.; Taylor, Jonathan P.; Ferek, Ronald J.; Garrett, Tim; Hobbs, Peter V.; Durkee, Philip A.; Nielsen, Kurt; Öström, Elisabeth; O'Dowd, Colin; Smith, Michael H.; Russell, Lynn M.; Flagan, Richard C.; Seinfeld, John H.; de Bock, Lieve; van Grieken, René E.; Hudson, James G.; Brooks, Ian;  Gasparovic, Richard F.;  Pockalny, Robert A.

    2000-08-01

    A case study of the effects of ship emissions on the microphysical, radiative, and chemical properties of polluted marine boundary layer clouds is presented. Two ship tracks are discussed in detail. In situ measurements of cloud drop size distributions, liquid water content, and cloud radiative properties, as well as aerosol size distributions (outside-cloud, interstitial, and cloud droplet residual particles) and aerosol chemistry, are presented. These are related to remotely sensed measurements of cloud radiative properties.The authors examine the processes behind ship track formation in a polluted marine boundary layer as an example of the effects of anthropogenic particulate pollution on the albedo of marine stratiform clouds.

  8. Raman lidar measurements of aerosol extinction and backscattering: 2. Derivation of aerosol real refractive index, single-scattering albedo, and humidification factor using Raman lidar and aircraft size distribution measurements

    NASA Astrophysics Data System (ADS)

    Ferrare, R. A.; Melfi, S. H.; Whiteman, D. N.; Evans, K. D.; Poellot, M.; Kaufman, Y. J.

    1998-08-01

    Aerosol backscattering and extinction profiles measured by the NASA Goddard Space Flight Center Scanning Raman Lidar (SRL) during the remote cloud sensing (RCS) intensive operations period (IOP) at the Department of Energy Atmospheric Radiation Measurement (ARM) southern Great Plains (SGP) site during two nights in April 1994 are discussed. These profiles are shown to be consistent with the simultaneous aerosol size distribution measurements made by a PCASP (Passive Cavity Aerosol Spectrometer Probe) optical particle counter flown on the University of North Dakota Citation aircraft. We describe a technique which uses both lidar and PCASP measurements to derive the dependence of particle size on relative humidity, the aerosol real refractive index n, and estimate the effective single-scattering albedo ω0. Values of n ranged between 1.4-1.5 (dry) and 1.37-1.47 (wet); ω0 varied between 0.7 and 1.0. The single-scattering albedo derived from this technique is sensitive to the manner in which absorbing particles are represented in the aerosol mixture; representing the absorbing particles as an internal mixture rather than the external mixture assumed here results in generally higher values of ω0. The lidar measurements indicate that the change in particle size with relative humidity as measured by the PCASP can be represented in the form discussed by Hanel [1976] with the exponent γ = 0.3 ± 0.05. The variations in aerosol optical and physical characteristics captured in the lidar and aircraft size distribution measurements are discussed in the context of the meteorological conditions observed during the experiment.

  9. Aerosol Measurements of the Fine and Ultrafine Particle Content of Lunar Regolith

    NASA Technical Reports Server (NTRS)

    Greenberg, Paul S.; Chen, Da-Ren; Smith, Sally A.

    2007-01-01

    We report the first quantitative measurements of the ultrafine (20 to 100 nm) and fine (100 nm to 20 m) particulate components of Lunar surface regolith. The measurements were performed by gas-phase dispersal of the samples, and analysis using aerosol diagnostic techniques. This approach makes no a priori assumptions about the particle size distribution function as required by ensemble optical scattering methods, and is independent of refractive index and density. The method provides direct evaluation of effective transport diameters, in contrast to indirect scattering techniques or size information derived from two-dimensional projections of high magnification-images. The results demonstrate considerable populations in these size regimes. In light of the numerous difficulties attributed to dust exposure during the Apollo program, this outcome is of significant importance to the design of mitigation technologies for future Lunar exploration.

  10. The effects of delay duration on visual working memory for orientation.

    PubMed

    Shin, Hongsup; Zou, Qijia; Ma, Wei Ji

    2017-12-01

    We used a delayed-estimation paradigm to characterize the joint effects of set size (one, two, four, or six) and delay duration (1, 2, 3, or 6 s) on visual working memory for orientation. We conducted two experiments: one with delay durations blocked, another with delay durations interleaved. As dependent variables, we examined four model-free metrics of dispersion as well as precision estimates in four simple models. We tested for effects of delay time using analyses of variance, linear regressions, and nested model comparisons. We found significant effects of set size and delay duration on both model-free and model-based measures of dispersion. However, the effect of delay duration was much weaker than that of set size, dependent on the analysis method, and apparent in only a minority of subjects. The highest forgetting slope found in either experiment at any set size was a modest 1.14°/s. As secondary results, we found a low rate of nontarget reports, and significant estimation biases towards oblique orientations (but no dependence of their magnitude on either set size or delay duration). Relative stability of working memory even at higher set sizes is consistent with earlier results for motion direction and spatial frequency. We compare with a recent study that performed a very similar experiment.

  11. Dealing with non-unique and non-monotonic response in particle sizing instruments

    NASA Astrophysics Data System (ADS)

    Rosenberg, Phil

    2017-04-01

    A number of instruments used as de-facto standards for measuring particle size distributions are actually incapable of uniquely determining the size of an individual particle. This is due to non-unique or non-monotonic response functions. Optical particle counters have non monotonic response due to oscillations in the Mie response curves, especially for large aerosol and small cloud droplets. Scanning mobility particle sizers respond identically to two particles where the ratio of particle size to particle charge is approximately the same. Images of two differently sized cloud or precipitation particles taken by an optical array probe can have similar dimensions or shadowed area depending upon where they are in the imaging plane. A number of methods exist to deal with these issues, including assuming that positive and negative errors cancel, smoothing response curves, integrating regions in measurement space before conversion to size space and matrix inversion. Matrix inversion (also called kernel inversion) has the advantage that it determines the size distribution which best matches the observations, given specific information about the instrument (a matrix which specifies the probability that a particle of a given size will be measured in a given instrument size bin). In this way it maximises use of the information in the measurements. However this technique can be confused by poor counting statistics which can cause erroneous results and negative concentrations. Also an effective method for propagating uncertainties is yet to be published or routinely implemented. Her we present a new alternative which overcomes these issues. We use Bayesian methods to determine the probability that a given size distribution is correct given a set of instrument data and then we use Markov Chain Monte Carlo methods to sample this many dimensional probability distribution function to determine the expectation and (co)variances - hence providing a best guess and an uncertainty for the size distribution which includes contributions from the non-unique response curve, counting statistics and can propagate calibration uncertainties.

  12. Relative efficiency and sample size for cluster randomized trials with variable cluster sizes.

    PubMed

    You, Zhiying; Williams, O Dale; Aban, Inmaculada; Kabagambe, Edmond Kato; Tiwari, Hemant K; Cutter, Gary

    2011-02-01

    The statistical power of cluster randomized trials depends on two sample size components, the number of clusters per group and the numbers of individuals within clusters (cluster size). Variable cluster sizes are common and this variation alone may have significant impact on study power. Previous approaches have taken this into account by either adjusting total sample size using a designated design effect or adjusting the number of clusters according to an assessment of the relative efficiency of unequal versus equal cluster sizes. This article defines a relative efficiency of unequal versus equal cluster sizes using noncentrality parameters, investigates properties of this measure, and proposes an approach for adjusting the required sample size accordingly. We focus on comparing two groups with normally distributed outcomes using t-test, and use the noncentrality parameter to define the relative efficiency of unequal versus equal cluster sizes and show that statistical power depends only on this parameter for a given number of clusters. We calculate the sample size required for an unequal cluster sizes trial to have the same power as one with equal cluster sizes. Relative efficiency based on the noncentrality parameter is straightforward to calculate and easy to interpret. It connects the required mean cluster size directly to the required sample size with equal cluster sizes. Consequently, our approach first determines the sample size requirements with equal cluster sizes for a pre-specified study power and then calculates the required mean cluster size while keeping the number of clusters unchanged. Our approach allows adjustment in mean cluster size alone or simultaneous adjustment in mean cluster size and number of clusters, and is a flexible alternative to and a useful complement to existing methods. Comparison indicated that we have defined a relative efficiency that is greater than the relative efficiency in the literature under some conditions. Our measure of relative efficiency might be less than the measure in the literature under some conditions, underestimating the relative efficiency. The relative efficiency of unequal versus equal cluster sizes defined using the noncentrality parameter suggests a sample size approach that is a flexible alternative and a useful complement to existing methods.

  13. A meta-analysis of educational interventions designed to enhance cultural competence in professional nurses and nursing students.

    PubMed

    Gallagher, Ruth W; Polanin, Joshua R

    2015-02-01

    Increasing professional nurses' and nursing students cultural competence has been identified as one way to decrease the disparity of care for vulnerable and minority groups, but effectiveness of training programs to increase competence remains equivocal. The purpose of this project is to synthesize educational interventions designed to increase cultural competence in professional nurses and nursing students. A systematic review and meta-analysis was conducted to synthesize all existing studies on increasing cultural competence. A comprehensive search and screen procedures was conducted to locate all cultural competence interventions implemented with professional nurses and nursing students. Two independent researchers screened and coded the included studies. Effect sizes were calculated for each study and a random-effects meta-analysis was conducted. A total of 25 studies were included in the review. Two independent syntheses were conducted given the disparate nature of the effect size metrics. For the synthesis of treatment-control designed studies, the results revealed a non-statistically significant increase in cultural competence (g¯=.38, 95% CI: -.05, .79, p=.08). Moderator analyses indicated significant variation as a function of the measurements, participant types, and funding source. The pretest-posttest effect size synthesis revealed a significant increase in overall cultural competence (g¯=.45, 95% CI: .24, .66, p<.01). Moderator analyses indicated, however, that the effect sizes varied as functions of the measurement, funding source, and publication type. Interventions to increase cultural competence have shown varied effectiveness. Greater research is required to improve these interventions and promote cultural competence. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Self-pollination rate and floral-display size in Asclepias syriaca (Common Milkweed) with regard to floral-visitor taxa

    PubMed Central

    2014-01-01

    Background Animals fertilize thousands of angiosperm species whose floral-display sizes can significantly influence pollinator behavior and plant reproductive success. Many studies have measured the interactions among pollinator behavior, floral-display size, and plant reproductive success, but few studies have been able to separate the effects of pollinator behavior and post-pollination processes on angiosperm sexual reproduction. In this study, we utilized the highly self-incompatible pollinium-pollination system of Asclepias syriaca (Common Milkweed) to quantify how insect visitors influenced male reproductive success measured as pollen removal, female reproductive success measured as pollen deposition, and self-pollination rate. We also determined how floral-display size impacts both visitor behavior and self-pollination rate. Results Four insect taxonomic orders visited A. syriaca: Coleoptera, Diptera, Hymenoptera, and Lepidoptera. We focused on three groups of visitor taxa within two orders (Hymenoptera and Lepidoptera) with sample sizes large enough for quantitative analysis: Apis mellifera (Western Honey Bee), Bombus spp. (bumble bees) and lepidopterans (butterflies and moths). Qualitatively, lepidopterans had the highest pollinator importance values, but the large variability in the lepidopteran data precluded meaningful interpretation of much of their behavior. The introduced A. mellifera was the most effective and most important diurnal pollinator with regard to both pollen removal and pollen deposition. However, when considering the self-incompatibility of A. syriaca, A. mellifera was not the most important pollinator because of its high self-pollination rate as compared to Bombus spp. Additionally, the rate of self-pollination increased more rapidly with the number of flowers per inflorescence in A. mellifera than in the native Bombus spp. Conclusions Apis mellifera’s high rate of self-pollination may have significant negative effects on both male and female reproductive successes in A. syriaca, causing different selection on floral-display size than native pollinators. PMID:24958132

  15. Effect of nanoparticle size on sessile droplet contact angle

    NASA Astrophysics Data System (ADS)

    Munshi, A. M.; Singh, V. N.; Kumar, Mukesh; Singh, J. P.

    2008-04-01

    We report a significant variation in the static contact angle measured on indium oxide (IO) nanoparticle coated Si substrates that have different nanoparticle sizes. These IO nanoparticles, which have well defined shape and sizes, were synthesized by chemical vapor deposition in a horizontal alumina tube furnace. The size of the IO nanoparticles was varied by changing the source material, substrate temperature, and the deposition time. A sessile droplet method was used to determine the macroscopic contact angle on these IO nanoparticle covered Si substrate using two different liquids: de-ionized water and diethylene glycol (DEG). It was observed that contact angle depends strongly on the nanoparticle size. The contact angle was found to vary from 24° to 67° for de-ionized water droplet and from 15° to 60° for DEG droplet, for the nanoparticle sizes varying from 14 to 620 nm. The contact angle decreases with a decrease in the particles size. We have performed a theoretical analysis to determine the dependence of contact angle on the nanoparticle size. This formulation qualitatively shows a similar trend of decrease in the contact angle with a decrease in nanoparticle size. Providing a rough estimate of nanoparticle size by sessile droplet contact angle measurement is the novelty in this work.

  16. Efficiencies for the statistics of size discrimination.

    PubMed

    Solomon, Joshua A; Morgan, Michael; Chubb, Charles

    2011-10-19

    Different laboratories have achieved a consensus regarding how well human observers can estimate the average orientation in a set of N objects. Such estimates are not only limited by visual noise, which perturbs the visual signal of each object's orientation, they are also inefficient: Observers effectively use only √N objects in their estimates (e.g., S. C. Dakin, 2001; J. A. Solomon, 2010). More controversial is the efficiency with which observers can estimate the average size in an array of circles (e.g., D. Ariely, 2001, 2008; S. C. Chong, S. J. Joo, T.-A. Emmanouil, & A. Treisman, 2008; K. Myczek & D. J. Simons, 2008). Of course, there are some important differences between orientation and size; nonetheless, it seemed sensible to compare the two types of estimate against the same ideal observer. Indeed, quantitative evaluation of statistical efficiency requires this sort of comparison (R. A. Fisher, 1925). Our first step was to measure the noise that limits size estimates when only two circles are compared. Our results (Weber fractions between 0.07 and 0.14 were necessary for 84% correct 2AFC performance) are consistent with the visual system adding the same amount of Gaussian noise to all logarithmically transduced circle diameters. We exaggerated this visual noise by randomly varying the diameters in (uncrowded) arrays of 1, 2, 4, and 8 circles and measured its effect on discrimination between mean sizes. Efficiencies inferred from all four observers significantly exceed 25% and, in two cases, approach 100%. More consistent are our measurements of just-noticeable differences in size variance. These latter results suggest between 62 and 75% efficiency for variance discriminations. Although our observers were no more efficient comparing size variances than they were at comparing mean sizes, they were significantly more precise. In other words, our results contain evidence for a non-negligible source of late noise that limits mean discriminations but not variance discriminations.

  17. Circadian type and bed-timing regularity in 654 retired seniors: correlations with subjective sleep measures.

    PubMed

    Monk, Timothy H; Buysse, Daniel J; Billy, Bart D; Fletcher, Mary E; Kennedy, Kathy S; Schlarb, Janet E; Beach, Scott R

    2011-02-01

    Using telephone interview data from retired seniors to explore how inter-individual differences in circadian type (morningness) and bed-timing regularity might be related to subjective sleep quality and quantity. MANCOVA with binary measures of morningness, stability of bedtimes, and stability of rise-times as independent variables; sleep measures as dependent variables; age, former shift work, and gender as covariates. Telephone interviews using a pseudo-random age-targeted sampling process. 654 retired seniors (65 y+, 363M, 291F). none. (1) circadian type (from Composite Scale of Morningness [CSM]), and stability of (2) bedtime and (3) rise-time from the Sleep Timing Questionnaire (STQ). Pittsburgh Sleep Quality Index (PSQI) score, time in bed, time spent asleep, and sleep efficiency, from Sleep Timing Questionnaire (STQ). Morning-type orientation, stability in bedtimes, and stability in rise-times were all associated with better sleep quality (P < 0.001, for all; effect sizes: 0.43, 0.33, and 0.27). Morningness was associated with shorter time in bed (P < 0.0001, effect size 0.45) and time spent asleep (P < 0.005, effect size 0.26). For bedtime and rise-time stability the direction of effect was similar but mostly weaker. In retired seniors, a morning-type orientation and regularity in bedtimes and rise-times appear to be correlated with improved subjective sleep quality and with less time spent in bed.

  18. Particle size dependent confinement and lattice strain effects in LiFePO4.

    PubMed

    Shahid, Raza; Murugavel, Sevi

    2013-11-21

    We report the intrinsic electronic properties of LiFePO4 (LFP) with different particle sizes measured by broad-band impedance spectroscopy and diffuse reflectance spectroscopy. The electronic properties show typical size-dependent effects with decreasing particle size (up to 150 nm). However, at the nanoscale level, we observed an enhancement in the polaronic conductivity about an order of magnitude. We found that the origin of the enhanced electronic conductivity in LFP is due to the significant lattice strain associated with the reduction of particle size. The observed lattice strain component corresponds to the compressive part which leads to a decrease in the hopping length of the polarons. We reproduce nonlinearities in the transport properties of LFP with particle size, to capture the interplay between confinement and lattice strain, and track the effects of strain on the electron-phonon interactions. These results could explain why nano-sized LFP has a better discharge capacity and higher rate capability than the bulk counterpart. We suggest that these new correlations will bring greater insight and better understanding for the optimization of LFP as a cathode material for advanced lithium ion batteries.

  19. Gap-based silviculture in a sierran mixed-conifer forest: effects of gap size on early survival and 7-year seedling growth

    Treesearch

    Robert A. York; John J. Battles; Robert C. Heald

    2007-01-01

    Experimental canopy gaps ranging in size from 0.1 to 1.0 ha (0.25 to 2.5 acres) were created in a mature mixed conifer forest at Blodgett Forest Research Station, California. Following gap creation, six species were planted in a wagon-wheel design and assessed for survival after two growing seasons. Study trees were measured after seven years to describe the effect of...

  20. The Effect of Size and Size Distribution on the Oxidation Kinetics and Plasmonics of Nanoscale Ag Particles

    DTIC Science & Technology

    2010-01-01

    examine the stability to oxidation of the silver nanoparticles , SERS measurements were carried out on a single dielectric ZnO nanowire core/silver...employed a simple and effective electroless (EL) plating approach to produce silver nanoparticles (NPs) on bare silicon, on dielectric ZnO nanowires (NWs...nature of silver, the Ag surface is easily oxidized in the air. Hence, it is important to understand the silver nanoparticle oxidation processes in

Top