Shinu, Pottathil; Singh, Varsha; Nair, Anroop; Mehrishi, Priya; Mehta, Sonia; Joshi, Ekta
2013-10-01
The study was designed to compare the efficacy of cetylpyridinium chloride (CPC) and sodium chloride (NaCl) decontamination method with N-acetyl L-Cystine (NALC) and sodium hydroxide (NaOH) decontamination (the reference method) method for the recovery of Mycobacterium tuberculosis (MTB) from clinically suspected cases of pulmonary tuberculosis. To evaluate CPC-NaCl and NALC-NaOH decontamination methods, sputum specimens (n = 796) were studied (culturing on Löwenstein-Jensen medium), and the performances were compared. The CPC-NaCl decontamination method demonstrated a sensitivity, specificity, negative predictive value, and positive predictive value of 97.99%, 87.53%, 70.19%, and 99.32%, respectively, when compared to NALC-NaOH decontamination method. In summary, CPC-NaCl decontamination method effectively detected significantly higher number of MTB cases (n = 208) than NALC-NaOH decontamination method (n = 149) particularly in sputum with scanty bacilli and smear-negative cases, indicating the potential of CPC-NaCl decontamination method to preserve paucibacillary cases more efficient than NALC-NaOH decontamination method. © 2013.
Material Compatibility for Historic Items Decontaminated with ...
Report This project continued research of the effects of decontamination methods for biological agents on materials identified as representative of types of irreplaceable objects or works of art found in museums and/or archive settings. In the previous research, surrogate materials were checked for compatibility with four decontamination methods: chlorine dioxide, hydrogen peroxide vapor, methyl bromide, and ethylene oxide gas. This project investigated the effects of gamma irradiation, which has also been shown to be an effective decontamination method for biological agents, on the surrogate test materials.
Yasutaka, Tetsuo; Naito, Wataru; Nakanishi, Junko
2013-01-01
The objective of the present study is to evaluate the cost and effectiveness of decontamination strategies in the special decontamination areas in Fukushima in regard to external radiation dose. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, analysis of cost and effectiveness suggests that decontamination costs for agricultural areas account for approximately 80% of the total decontamination cost, of which approximately 60% is associated with storage. In addition, the costs of decontamination per person per unit area are estimated to vary greatly. Appropriate selection of decontamination methods may significantly decrease decontamination costs, allowing more meaningful decontamination in terms of the limited budget. Our analysis can help in examining the prioritization of decontamination areas from the viewpoints of cost and effectiveness in reducing the external dose. Decontamination strategies should be determined according to air dose rates and future land-use plans. PMID:24069398
Yasutaka, Tetsuo; Naito, Wataru; Nakanishi, Junko
2013-01-01
The objective of the present study is to evaluate the cost and effectiveness of decontamination strategies in the special decontamination areas in Fukushima in regard to external radiation dose. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, analysis of cost and effectiveness suggests that decontamination costs for agricultural areas account for approximately 80% of the total decontamination cost, of which approximately 60% is associated with storage. In addition, the costs of decontamination per person per unit area are estimated to vary greatly. Appropriate selection of decontamination methods may significantly decrease decontamination costs, allowing more meaningful decontamination in terms of the limited budget. Our analysis can help in examining the prioritization of decontamination areas from the viewpoints of cost and effectiveness in reducing the external dose. Decontamination strategies should be determined according to air dose rates and future land-use plans.
Buttner, Mark P.; Cruz, Patricia; Stetzenbach, Linda D.; Klima-Comba, Amy K.; Stevens, Vanessa L.; Cronin, Tracy D.
2004-01-01
The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus (“Bacillus subtilis subsp. niger,” also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 105 to 106 CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies. PMID:15294810
Buttner, Mark P; Cruz, Patricia; Stetzenbach, Linda D; Klima-Comba, Amy K; Stevens, Vanessa L; Cronin, Tracy D
2004-08-01
The efficacy of currently available decontamination strategies for the treatment of indoor furnishings contaminated with bioterrorism agents is poorly understood. Efficacy testing of decontamination products in a controlled environment is needed to ensure that effective methods are used to decontaminate domestic and workplace settings. An experimental room supplied with materials used in office furnishings (i.e., wood laminate, painted metal, and vinyl tile) was used with controlled dry aerosol releases of endospores of Bacillus atrophaeus ("Bacillus subtilis subsp. niger," also referred to as BG), a Bacillus anthracis surrogate. Studies were performed using two test products, a foam decontaminant and chlorine dioxide gas. Surface samples were collected pre- and posttreatment with three sampling methods and analyzed by culture and quantitative PCR (QPCR). Additional aerosol releases with environmental background present on the surface materials were also conducted to determine if there was any interference with decontamination or sample analysis. Culture results indicated that 10(5) to 10(6) CFU per sample were present on surfaces before decontamination. After decontamination with the foam, no culturable B. atrophaeus spores were detected. After decontamination with chlorine dioxide gas, no culturable B. atrophaeus was detected in 24 of 27 samples (89%). However, QPCR analysis showed that B. atrophaeus DNA was still present after decontamination with both methods. Environmental background material had no apparent effect on decontamination, but inhibition of the QPCR assay was observed. These results demonstrate the effectiveness of two decontamination methods and illustrate the utility of surface sampling and QPCR analysis for the evaluation of decontamination strategies.
Anthrax Sampling and Decontamination: Technology Trade-Offs
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, Phillip N.; Hamachi, Kristina; McWilliams, Jennifer
2008-09-12
The goal of this project was to answer the following questions concerning response to a future anthrax release (or suspected release) in a building: 1. Based on past experience, what rules of thumb can be determined concerning: (a) the amount of sampling that may be needed to determine the extent of contamination within a given building; (b) what portions of a building should be sampled; (c) the cost per square foot to decontaminate a given type of building using a given method; (d) the time required to prepare for, and perform, decontamination; (e) the effectiveness of a given decontamination methodmore » in a given type of building? 2. Based on past experience, what resources will be spent on evaluating the extent of contamination, performing decontamination, and assessing the effectiveness of the decontamination in abuilding of a given type and size? 3. What are the trade-offs between cost, time, and effectiveness for the various sampling plans, sampling methods, and decontamination methods that have been used in the past?« less
DNA decontamination methods for internal quality management in clinical PCR laboratories.
Wu, Yingping; Wu, Jianyong; Zhang, Zhihui; Cheng, Chen
2018-03-01
The polymerase chain reaction (PCR) technique, one of the most commonly applied methods in diagnostic and molecular biology, has a frustrating downside: the occurrence of false-positive signals due to contamination. In previous research, various DNA decontamination methods have been developed to overcome this limitation. Unfortunately, the use of random or poorly focused sampling methods for monitoring air and/or object surfaces leads to the incomplete elimination during decontamination procedures. We herein attempted to develop a novel DNA decontamination method (environmental surveillance, including surface and air sampling) and quality management program for clinical molecular diagnostic laboratories (or clinical PCR laboratories). Here, we performed a step-by-step evaluation of current DNA decontamination methods and developed an effective procedure for assessing the presence of decontaminating DNA via PCR analysis. Performing targeted environmental surveillance by sampling, which reached optimal performance over 2 weeks, and the decontamination process had been verified as reliable. Additionally, the process was validated to not affect PCR amplification efficiency based on a comparative study. In this study, effective guidelines for DNA decontamination were developed. The method employed ensured that surface DNA contamination could be effectively identified and eliminated. Furthermore, our study highlighted the importance of overall quality assurance and good clinical laboratory practices for preventing contamination, which are key factors for compliance with regulatory or accreditation requirements. Taken together, we provided the evidence that the presented scheme ranged from troubleshooting to the elimination of surface contamination, could serve as critical foundation for developing regular environmental surveillance guidelines for PCR laboratories. © 2017 Wiley Periodicals, Inc.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dill, G.S.; Leonard, R.D.
1991-04-01
A study was performed to determine the effect of three commonly used field decontaminants, DS2, super tropical bleach (STB), and the M270 Decontaminating Kit, Individual (DKIE), on the Resuscitation Device, Chemical, Individual (RDIC). The RDIC system was analyzed to determine which components were accessible to chemical agents and could be degraded by them. The chemical agent susceptibility of the silicone rubber components is the weakest point in the RDIC system. The lack of accessibility of key components to the wetted DKIE wipes and the deterioration of key components by DS2 eliminates these two methods as possible decontaminant methods. STB hadmore » no noticeable effects on the RDIC and is recommended as the best field decontamination method.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hovanec, J.W.; Szafraniec, L.L.; Albizo, J.M.
1993-04-01
Standard decontaminant formulations, aqueous sodium hydroxide and aqueous sodium hypochlorite, were providing slow and incomplete results when used to decontaminate certain operating facilities at the Johnston Atoll Chemical Agent Disposal System and the Chemical Agent Disposal System (Utah). A study was undertaken to define the capabilities and limitations of using concentrated sodium hydroxide to decontaminate VX, the effect of adding hydrogen peroxide to the sodium hydroxide for the decontamination of VX, the efficacy of aqueous oxone for the decontamination of VX, and the efficacy of oxone in a water/1-methyl-2-pyrrolidinone (MP) mixture for the decontamination of HD. Using aqueous sodium hydroxidemore » alone was not desirable since the formation of toxic EA2192 could not be averted. However, the addition of hydrogen peroxide resulted in effective VX decontamination without EA2192 formation. Aqueous oxone was also found to be effective for both VX and HD. The incorporation of MP did little to improve HD dissolution and reacted with the oxone to reduce the effective usable life of the decontamination solution. Thus, the use of MP in HD decontamination was not recommended.« less
Evaluation of Microwave Steam Bags for the Decontamination of Filtering Facepiece Respirators
Fisher, Edward M.; Williams, Jessica L.; Shaffer, Ronald E.
2011-01-01
Reusing filtering facepiece respirators (FFRs) has been suggested as a strategy to conserve available supplies for home and healthcare environments during an influenza pandemic. For reuse to be possible, used FFRs must be decontaminated before redonning to reduce the risk of virus transmission; however, there are no approved methods for FFR decontamination. An effective method must reduce the microbial threat, maintain the function of the FFR, and present no residual chemical hazard. The method should be readily available, inexpensive and easily implemented by healthcare workers and the general public. Many of the general decontamination protocols used in healthcare and home settings are unable to address all of the desired qualities of an efficient FFR decontamination protocol. The goal of this study is to evaluate the use of two commercially available steam bags, marketed to the public for disinfecting infant feeding equipment, for FFR decontamination. The FFRs were decontaminated with microwave generated steam following the manufacturers' instructions then evaluated for water absorption and filtration efficiency for up to three steam exposures. Water absorption of the FFR was found to be model specific as FFRs constructed with hydrophilic materials absorbed more water. The steam had little effect on FFR performance as filtration efficiency of the treated FFRs remained above 95%. The decontamination efficacy of the steam bag was assessed using bacteriophage MS2 as a surrogate for a pathogenic virus. The tested steam bags were found to be 99.9% effective for inactivating MS2 on FFRs; however, more research is required to determine the effectiveness against respiratory pathogens. PMID:21525995
Carter, Holly; Amlôt, Richard
2016-01-01
Introduction: Mass casualty decontamination is an intervention employed by first responders at the scene of an incident involving noxious contaminants. Many countries have sought to address the challenge of decontaminating large numbers of affected casualties through the provision of rapidly deployable temporary showering structures, with accompanying decontamination protocols. In this paper we review decontamination guidance for emergency responders and associated research evidence, in order to establish to what extent psychosocial aspects of casualty management have been considered within these documents. The review focuses on five psychosocial aspects of incident management: likely public behaviour; responder management style; communication strategy; privacy/ modesty concerns; and vulnerable groups. Methods: Two structured literature reviews were carried out; one to identify decontamination guidance documents for first responders, and another to identify evidence which is relevant to the understanding of the psychosocial aspects of mass decontamination. The guidance documents and relevant research were reviewed to identify whether the guidance documents contain information relating to psychosocial issues and where it exists, that the guidance is consistent with the existing evidence-base. Results: Psychosocial aspects of incident management receive limited attention in current decontamination guidance. In addition, our review has identified a number of gaps and inconsistencies between guidance and research evidence. For each of the five areas we identify: what is currently presented in guidance documents, to what extent this is consistent with the existing research evidence and where it diverges. We present a series of evidence-based recommendations for updating decontamination guidance to address the psychosocial aspects of mass decontamination. Conclusions: Effective communication and respect for casualties’ needs are critical in ensuring decontamination is completed quickly and effectively. We identify a number of areas requiring further research including: identifying effective methods for communicating in an emergency; better understanding of the needs of vulnerable groups during decontamination; effective training for emergency responders on psychosocial issues, and pre-incident public education for incidents involving emergency decontamination. It is essential that the psychosocial aspects of mass decontamination are not neglected in the pursuit of solely technical solutions. PMID:27790383
Effectiveness of Spray-Based Decontamination Methods for ...
Report The objective of this project was to assess the effectiveness of spray-based common decontamination methods for inactivating Bacillus (B.) atrophaeus (surrogate for B. anthracis) spores and bacteriophage MS2 (surrogate for foot and mouth disease virus [FMDV]) on selected test surfaces (with or without a model agricultural soil load). Relocation of viable viruses or spores from the contaminated coupon surfaces into aerosol or liquid fractions during the decontamination methods was investigated. This project was conducted to support jointly held missions of the U.S. Department of Homeland Security (DHS) and the U.S. Environmental Protection Agency (EPA). Within the EPA, the project supports the mission of EPA’s Homeland Security Research Program (HSRP) by providing relevant information pertinent to the decontamination of contaminated areas resulting from a biological incident.
Amlôt, Richard; Carter, Holly; Riddle, Lorna; Larner, Joanne; Chilcott, Robert P
2017-01-01
Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an "Initial Operational Response" by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer's forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions, improvised dry decontamination may not be performed correctly or safely.
Riddle, Lorna; Larner, Joanne
2017-01-01
Previous studies have demonstrated that rapid evacuation, disrobing and emergency decontamination can enhance the ability of emergency services and acute hospitals to effectively manage chemically-contaminated casualties. The purpose of this human volunteer study was to further optimise such an “Initial Operational Response” by (1) identifying an appropriate method for performing improvised skin decontamination and (2) providing guidance for use by first responders and casualties. The study was performed using two readily available, absorbent materials (paper towels and incontinence pads). The decontamination effectiveness of the test materials was measured by quantifying the amount of a chemical warfare agent simulant (methyl salicylate) removed from each volunteer’s forearm skin. Results from the first study demonstrated that simulant recovery was lower in all of the dry decontamination conditions when compared to matched controls, suggesting that dry decontamination serves to reduce chemical exposure. Blotting in combination with rubbing was the most effective form of decontamination. There was no difference in effectiveness between the two absorbent materials. In the following study, volunteers performed improvised dry decontamination, either with or without draft guidelines. Volunteers who received the guidance were able to carry out improvised dry decontamination more effectively, using more of the absorbent product (blue roll) to ensure that all areas of the body were decontaminated and avoiding cross-contamination of other body areas by working systematically from the head downwards. Collectively, these two studies suggest that absorbent products that are available on ambulances and in acute healthcare settings may have generic applicability for improvised dry decontamination. Wherever possible, emergency responders and healthcare workers should guide casualties through decontamination steps; in the absence of explicit guidance and instructions, improvised dry decontamination may not be performed correctly or safely. PMID:28622352
Reducing Risk of Salmonellosis through Egg Decontamination Processes.
Keerthirathne, Thilini Piushani; Ross, Kirstin; Fallowfield, Howard; Whiley, Harriet
2017-03-22
Eggs have a high nutritional value and are an important ingredient in many food products. Worldwide foodborne illnesses, such as salmonellosis linked to the consumption of eggs and raw egg products, are a major public health concern. This review focuses on previous studies that have investigated the procedures for the production of microbiologically safe eggs. Studies exploring pasteurization and decontamination methods were investigated. Gamma irradiation, freeze drying, hot air, hot water, infra-red, atmospheric steam, microwave heating and radiofrequency heating are all different decontamination methods currently considered for the production of microbiologically safe eggs. However, each decontamination procedure has different effects on the properties and constituents of the egg. The pasteurization processes are the most widely used and best understood; however, they influence the coagulation, foaming and emulsifying properties of the egg. Future studies are needed to explore combinations of different decontamination methods to produce safe eggs without impacting the protein structure and usability. Currently, eggs which have undergone decontamination processes are primarily used in food prepared for vulnerable populations. However, the development of a decontamination method that does not affect egg properties and functionality could be used in food prepared for the general population to provide greater public health protection.
Reducing Risk of Salmonellosis through Egg Decontamination Processes
Keerthirathne, Thilini Piushani; Ross, Kirstin; Fallowfield, Howard; Whiley, Harriet
2017-01-01
Eggs have a high nutritional value and are an important ingredient in many food products. Worldwide foodborne illnesses, such as salmonellosis linked to the consumption of eggs and raw egg products, are a major public health concern. This review focuses on previous studies that have investigated the procedures for the production of microbiologically safe eggs. Studies exploring pasteurization and decontamination methods were investigated. Gamma irradiation, freeze drying, hot air, hot water, infra-red, atmospheric steam, microwave heating and radiofrequency heating are all different decontamination methods currently considered for the production of microbiologically safe eggs. However, each decontamination procedure has different effects on the properties and constituents of the egg. The pasteurization processes are the most widely used and best understood; however, they influence the coagulation, foaming and emulsifying properties of the egg. Future studies are needed to explore combinations of different decontamination methods to produce safe eggs without impacting the protein structure and usability. Currently, eggs which have undergone decontamination processes are primarily used in food prepared for vulnerable populations. However, the development of a decontamination method that does not affect egg properties and functionality could be used in food prepared for the general population to provide greater public health protection. PMID:28327524
Park, Shin-Young; Kim, Kyoung-Hwa; Shin, Seung-Yun; Koo, Ki-Tae; Lee, Yong-Moo; Chung, Chong-Pyoung; Seol, Yang-Jo
2015-06-01
This study evaluated decontamination methods using a dental water jet and dental floss on microthreaded implants for regenerative periimplantitis therapy. In 6 beagle dogs, experimental periimplantitis was induced, and decontamination procedures, including manual saline irrigation (control group), saline irrigation using a dental water jet (group 1) and saline irrigation using a dental water jet with dental flossing (group 2), were performed. After in situ decontamination procedures, some of the implant fixtures (n = 4 per group) were retrieved for analysis by SEM, whereas other fixtures (n = 4 per group) underwent regenerative therapy. After 3 months of healing, the animals were killed. The SEM examination indicated that decontamination of the implant surfaces was the most effective in group 2, with no changes in implant surface morphology. The histological examination also revealed that group 2 achieved significantly greater amounts of newly formed bone (6.75 ± 2.19 mm; P = 0.018), reosseointegration (1.88 ± 1.79 mm; P = 0.038), and vertical bone fill (26.69 ± 18.42%; P = 0.039). Decontamination using a dental water jet and dental floss on microthreaded implants showed positive mechanical debridement effects and positive bone regeneration effects.
de By, Theo M M H; McDonald, Carl; Süßner, Susanne; Davies, Jill; Heng, Wee Ling; Jashari, Ramadan; Bogers, Ad J J C; Petit, Pieter
2017-11-01
Surgeons needing human cardiovascular tissue for implantation in their patients are confronted with cardiovascular tissue banks that use different methods to identify and decontaminate micro-organisms. To elucidate these differences, we compared the quality of processing methods in 20 tissue banks and 1 reference laboratory. We did this to validate the results for accepting or rejecting tissue. We included the decontamination methods used and the influence of antibiotic cocktails and residues with results and controls. The minor details of the processes were not included. To compare the outcomes of microbiological testing and decontamination methods of heart valve allografts in cardiovascular tissue banks, an international quality round was organized. Twenty cardiovascular tissue banks participated in this quality round. The quality round method was validated first and consisted of sending purposely contaminated human heart valve tissue samples with known micro-organisms to the participants. The participants identified the micro-organisms using their local decontamination methods. Seventeen of the 20 participants correctly identified the micro-organisms; if these samples were heart valves to be released for implantation, 3 of the 20 participants would have decided to accept their result for release. Decontamination was shown not to be effective in 13 tissue banks because of growth of the organisms after decontamination. Articles in the literature revealed that antibiotics are effective at 36°C and not, or less so, at 2-8°C. The decontamination procedure, if it is validated, will ensure that the tissue contains no known micro-organisms. This study demonstrates that the quality round method of sending contaminated tissues and assessing the results of the microbiological cultures is an effective way of validating the processes of tissue banks. Only when harmonization, based on validated methods, has been achieved, will surgeons be able to fully rely on the methods used and have confidence in the consistent sterility of the tissue grafts. Tissue banks should validate their methods so that all stakeholders can trust the outcomes. © The Author 2017. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
Yair, Simo; Ofer, Butnaro; Arik, Eisenkraft; Shai, Shrot; Yossi, Rosman; Tzvika, Dushnitsky; Amir, Krivoy
2008-01-01
One of the major challenges in dealing with chemical warfare agent (CWA) dispersal, whether in the battlefield or after a terror act, is decontamination and rehabilitation of any contaminated area. Organophosphates (OPs) are considered to be among the deadliest CWAs to date. Other OPs are used as pesticides in modern agriculture, and are considered environmentally hazardous. Current methods for OP decontamination are either dangerous or insufficiently effective. As a promising solution for this problem, bioremediation--the use of biocomponents for environmental remediation--is a potentially effective, safe, and environment-friendly method. The technology relies on several enzymatic mechanisms, and can be applied in various ways. We will review recent achievements and potential applications, such as biocatalyst-containing foams and an enzymatic sponge, for environmental as well as personal exterior decontamination.
Time-Dependent Effects of Chlorhexidine Soaks on Grossly Contaminated Bone
2012-10-01
decontaminate . Methods: Fifty four bone segments were harvested from fresh frozen porcine legs. Each specimen was dropped onto a Mueller Hinton medium that was...P, 0.0001) and no difference between the 2%CHLand 4%CHLgroups. Conclusions: This study provides new data supporting the use of CHL to decontaminate ...bone may expedite the process of biofilm formation.1,6,7 Therefore, grossly contaminated bone seg- ments should be decontaminated with effective
Lin, Tzu-Hsien; Chen, Chih-Chieh; Kuo, Chung-Wen
2017-01-01
This study investigates the effects of five decontamination methods on the filter quality (qf) of three commercially available electret masks—N95, Gauze and Spunlace nonwoven masks. Newly developed evaluation methods, the overall filter quality (qf,o) and the qf ratio were applied to evaluate the effectiveness of decontamination methods for respirators. A scanning mobility particle sizer is utilized to measure the concentration of polydispersed particles with diameter 14.6–594 nm. The penetration of particles and pressure drop (Δp) through the mask are used to determine qf and qf,o. Experimental results reveal that the most penetrating particle size (MPS) for the pre-decontaminated N95, Gauze and Spunlace masks were 118 nm, 461 nm and 279 nm, respectively, and the respective penetration rates were 2.6%, 23.2% and 70.0%. The Δp through the pretreated N95 masks was 9.2 mm H2O at the breathing flow rate of heavy-duty workers, exceeding the Δp values obtained through Gauze and Spunlace masks. Decontamination increased the sizes of the most penetrating particles, changing the qf values of all of the masks: qf fell as particle size increased because the penetration increased. Bleach increased the Δp of N95, but destroyed the Gauze mask. However, the use of an autoclave reduces the Δp values of both the N95 and the Gauze mask. Neither the rice cooker nor ethanol altered the Δp of the Gauze mask. Chemical decontamination methods reduced the qf,o values for the three electret masks. The value of qf,o for PM0.1 exceeded that for PM0.1–0.6, because particles smaller than 100 nm had lower penetration, resulting in a better qf for a given pressure drop. The values of qf,o, particularly for PM0.1, reveal that for the tested treatments and masks, physical decontamination methods are less destructive to the filter than chemical methods. Nevertheless, when purchasing new or reusing FFRs, penetration should be regarded as the priority. PMID:29023492
Removal of uranyl ions by p-hexasulfonated calyx[6]arene acid
NASA Astrophysics Data System (ADS)
Popescu (Hoştuc), Ioana-Carmen; Petru, Filip; Humelnicu, Ionel; Mateescu, Marina; Militaru, Ecaterina; Humelnicu, Doina
2014-10-01
Radioactive pollution is a significant threat for the people's health. Therefore highly effective radioactive decontamination methods are required. Ion exchange, biotechnologies and phytoremediation in constructed wetlands have been used as radioactive decontamination technologies for uranium contaminated soil and water remediation. Recently, beside those classical methods the calix[n]arenic derivatives' utilization as radioactive decontaminators has jogged attention. The present work aims to present the preliminary research results of uranyl ion sorption studies on the p-hexasulfonated calyx[6]arenic acid. The effect of temperature, contact time, sorbent amount and uranyl concentration variation on sorption efficiency was investigated. Isotherm models revealed that the sorption process fit better Langmuir isotherm.
Kassouf, Nick; Syed, Sara; Larner, Joanne; Amlôt, Richard
2017-01-01
The UK’s Initial Operational Response (IOR) is a revised process for the medical management of mass casualties potentially contaminated with hazardous materials. A critical element of the IOR is the introduction of immediate, on-scene disrobing and decontamination of casualties to limit the adverse health effects of exposure. Ad hoc cleansing of the skin with dry absorbent materials has previously been identified as a potential means of facilitating emergency decontamination. The purpose of this study was to evaluate the in vitro oil and water absorbency of a range of materials commonly found in the domestic and clinical environments and to determine the effectiveness of a small, but representative selection of such materials in skin decontamination, using an established ex vivo model. Five contaminants were used in the study: methyl salicylate, parathion, diethyl malonate, phorate and potassium cyanide. In vitro measurements of water and oil absorbency did not correlate with ex vivo measurements of skin decontamination. When measured ex vivo, dry decontamination was consistently more effective than a standard wet decontamination method (“rinse-wipe-rinse”) for removing liquid contaminants. However, dry decontamination was ineffective against particulate contamination. Collectively, these data confirm that absorbent materials such as wound dressings and tissue paper provide an effective, generic capability for emergency removal of liquid contaminants from the skin surface, but that wet decontamination should be used for non-liquid contaminants. PMID:28152053
2006-06-01
Decontamination assessment of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surfaces using a hydrogen...resistant to commonly used disinfectants and require the use of chemical sterilants † to effectively decontaminate exposed areas. Since anthrax...spores can aerosolise the use of vaporous sterilants in the remediation of contaminated areas is desirable. A number of vaporous sterilants exist which
Skin decontamination: principles and perspectives.
Chan, Heidi P; Zhai, Hongbo; Hui, Xiaoying; Maibach, Howard I
2013-11-01
Skin decontamination is the primary intervention needed in chemical, biological and radiological exposures, involving immediate removal of the contaminant from the skin performed in the most efficient way. The most readily available decontamination system on a practical basis is washing with soap and water or water only. Timely use of flushing with copious amounts of water may physically remove the contaminant. However, this traditional method may not be completely effective, and contaminants left on the skin after traditional washing procedures can have toxic consequences. This article focuses on the principles and practices of skin decontamination.
Benefits of automated surface decontamination of a radioiodine ward.
Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan
2012-02-01
A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.
Athiban, Prakash P; Borthakur, Bikash Jyoti; Ganesan, S; Swathika, B
2012-01-01
Aim: The aim of this study was to evaluate the antimicrobial efficacy of Aloe vera and to determine its effectiveness in decontaminating gutta percha cones. Materials and Methods: A concentrated extract of Aloe vera was used to check for the antimicrobial efficacy using the agar well diffusion method. Presence of zones’ of diffusion was identified against three common GP contaminants namely, E.coli, E.faecalis and Staph. aureus. New GP Cones, freshly taken out of the packet were then decontaminated for 1minute using Aloe vera gel and then placed in thioglycolate broth to check for the presence of turbidity. Results: The zones of inhibition on the agar plate were measured as 24mm,21mm and 24mm respectively. The broth remained clear even after 48 hours of incubation. Conclusion: We conclude that Aloe vera is indeed effective as a GP decontaminant and it holds a promising future as a medium for storage of GP cones. PMID:22876011
Effectiveness of a decontamination method for donor corneas.
Badenoch, P R; Alfrich, S J; Wedding, T R; Coster, D J
1988-03-01
A retrospective study was made of the effectiveness of an eye bank decontamination and storage method. A comparison was made between microbial cultures taken from the limbus at enucleation and from scleral remnants recovered after surgery. Organisms were isolated from the limbus of 73% of donor eyes and from 4% of remnants. Standard eye bank procedures were found to eradicate gut and skin organisms, including candida, from donor tissue.
A rapid and inexpensive bioassay to evaluate the decontamination of organophosphates.
Claborn, David M; Martin-Brown, Skylar A; Sagar, Sanjay Gupta; Durham, Paul
2012-01-01
An inexpensive and rapid bioassay using adult red flour beetles was developed for use in assessing the decontamination of environments containing organophosphates and related chemicals. A decontamination protocol was developed which demonstrated that 2 to 3 applications of 5% bleach solution were required to obtain nearly complete decontamination of malathion. The bioassay was also used to screen common household cleaners as potential decontaminating agents, but only 5% bleach was effective at improving survival of insects on steel plates treated with 25% malathion. A toxic degradation product (malaoxon) was detected using gas chromatography/mass spectrophotometry; this toxin affected the decontamination efficacy and resulted in continued toxicity to the beetles until subsequent decontaminations. The bioassay provides evidence to support the use of red flour beetles as a sensitive, less expensive method for determining safety levels of environments contaminated with malathion and other toxins, and may have application in the study of chemical warfare agents.
Aerosol tests conducted at Aberdeen Proving Grounds MD.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brockmann, John E.; Lucero, Daniel A.; Servantes, Brandon Lee
Test data are reported that demonstrate the deposition from a spray dispersion system (Illinois Tool Works inductively charging rotary atomization nozzle) for application of decontamination solution to various surfaces in the passenger cabin of a Boeing 737 aircraft. The decontamination solution (EnviroTru) was tagged with a known concentration of fluorescein permitting determination of both airborne decontaminant concentration and surface deposited decontaminant solution so that the effective deposition rates and surface coverage could be determined and correlated with the amount of material sprayed. Six aerosol dispersion tests were conducted. In each test, aluminum foil deposition coupons were set out throughout themore » passenger area and the aerosol was dispersed. The aerosol concentration was measured with filter samplers as well as with optical techniques Average aerosol deposition ranged from 3 to 15 grams of decontamination solution per square meter. Some disagreement was observed between various instruments utilizing different measurement principles. These results demonstrate a potentially effective method to disperse decontaminant to interior surfaces of a passenger aircraft.« less
[Decontamination of chemical and biological warfare agents].
Seto, Yasuo
2009-01-01
Chemical and biological warfare agents (CBWA's) are diverse in nature; volatile acute low-molecular-weight toxic compounds, chemical warfare agents (CWA's, gaseous choking and blood agents, volatile nerve gases and blister agents, nonvolatile vomit agents and lacrymators), biological toxins (nonvolatile low-molecular-weight toxins, proteinous toxins) and microbes (bacteria, viruses, rickettsiae). In the consequence management against chemical and biological terrorism, speedy decontamination of victims, facilities and equipment is required for the minimization of the damage. In the present situation, washing victims and contaminated materials with large volumes of water is the basic way, and additionally hypochlorite salt solution is used for decomposition of CWA's. However, it still remains unsolved how to dispose large volumes of waste water, and the decontamination reagents have serious limitation of high toxicity, despoiling nature against the environments, long finishing time and non-durability in effective decontamination. Namely, the existing decontamination system is not effective, nonspecifically affecting the surrounding non-target materials. Therefore, it is the urgent matter to build up the usable decontamination system surpassing the present technologies. The symposiast presents the on-going joint project of research and development of the novel decontamination system against CBWA's, in the purpose of realizing nontoxic, fast, specific, effective and economical terrorism on-site decontamination. The projects consists of (1) establishment of the decontamination evaluation methods and verification of the existing technologies and adaptation of bacterial organophosphorus hydrolase, (2) development of adsorptive elimination technologies using molecular recognition tools, and (4) development of deactivation technologies using photocatalysis.
A multi-parametric assessment of decontamination protocols for the subglacial Lake Ellsworth probe.
Magiopoulos, I; McQuillan, J S; Burd, C L; Mowlem, M; Tsaloglou, M-N
2016-04-01
Direct measurement and sampling of pristine environments, such as subglacial lakes, without introducing contaminating microorganisms and biomolecules from the surface, represents a significant engineering and microbiological challenge. In this study, we compare methods for decontamination of titanium grade 5 surfaces, the material extensively used to construct a custom-made probe for reaching, measuring and sampling subglacial Lake Ellsworth in West Antarctica. Coupons of titanium were artificially contaminated with Pseudomonas fluorescens bacteria and then exposed to a number of decontamination procedures. The most effective sterilants were (i) hydrogen peroxide vapour, and (ii) Biocleanse™, a commercially available, detergent-based biocidal solution. After each decontamination procedure the bacteria were incapable of proliferation, and showed no evidence of metabolic activity based on the generation of adenosine triphosphate (ATP). The use of ultraviolet irradiation or ethyl alcohol solution was comparatively ineffective for sterilisation. Hydrogen peroxide vapour and ultraviolet irradiation, which directly damage nucleic acids, were the most effective methods for removing detectable DNA, which was measured using 16S rRNA gene copy number and fluorescence-based total DNA quantification. Our results have not only been used to tailor the Ellsworth probe decontamination process, but also hold value for subsequent engineering projects, where high standards of decontamination are required. Copyright © 2016 Elsevier B.V. All rights reserved.
Subramanya, Supram Hosuru; Pai, Vasudha; Bairy, Indira; Nayak, Niranjan; Gokhale, Shishir; Sathian, Brijesh
2018-02-13
Raw vegetables including flowers, leaves, stems, and roots are important carriers of food borne pathogens. We evaluated the bacteriological contamination of unwashed coriander leaves, and effectiveness of cleansing with 0.1% potassium permanganate solution as decontamination method. Significant bacterial contamination including pathogens like Salmonella species and Aeromonas species were isolated from unwashed coriander leaves. Decontamination with 0.1% potassium permanganate was found to be more effective than three steps wash with sterile water.
Calfee, M. Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-01-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration. PMID:27362274
Calfee, M Worth; Tufts, Jenia; Meyer, Kathryn; McConkey, Katrina; Mickelsen, Leroy; Rose, Laura; Dowell, Chad; Delaney, Lisa; Weber, Angela; Morse, Stephen; Chaitram, Jasmine; Gray, Marshall
2016-12-01
Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures. Both decontamination procedures were quantitatively evaluated on three types of sample packaging materials (corrugated fiberboard, polystyrene foam, and polyethylene plastic), and two contamination mechanisms (wet or dry inoculums). Contaminant transfer results suggested that size-appropriate gloves should be worn by personnel, templates should not be taped to or removed from surfaces, and primary receptacles should be selected carefully. The decontamination tests indicated that wipe-based decontamination procedures may be more effective than spray-based procedures; efficacy was not influenced by material type but was affected by the inoculation method. Incomplete surface decontamination was observed in all tests with dry inoculums. This study provides a foundation for optimizing current B. anthracis response procedures to minimize contaminant exfiltration.
Szabo, Jeffrey G; Muhammad, Nur; Heckman, Lee; Rice, Eugene W; Hall, John
2012-04-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone.
Muhammad, Nur; Heckman, Lee; Rice, Eugene W.; Hall, John
2012-01-01
Germination was evaluated as an enhancement to decontamination methods for removing Bacillus spores from drinking water infrastructure. Germinating spores before chlorinating cement mortar or flushing corroded iron was more effective than chlorinating or flushing alone. PMID:22267659
Report of decontamination at Tominari Elementary School.
Katsumi, S
2016-12-01
On 19 April 2011, the Ministry of Education, Culture, Sports, Science, and Technology designated 13 elementary schools, including Tominari Elementary School in Date city, as high-dose schools that needed to restrict outdoor activities due to the effects of the accident at Fukushima Daiichi nuclear power plant. Approximately 1 week later, the municipal government took action to remove the topsoil from the school grounds, and the prohibition of outdoor activities at Tominari Elementary School was lifted. The school staff continued to work on decontaminating the surrounding areas using high-pressure washers and brushes. There were certain positive outcomes, but a more effective decontamination method was required. In July 2011, the municipal government started an environmental remediation project, both inside and outside the school buildings, with researchers and decontamination workers at Tominari Elementary School, involving members of the Parent-Teacher Association (PTA), local communities, and volunteers using various effective and specialised forms of decontamination. As a result, Tominari Elementary School was able to recommence swimming lessons at the end of the first semester, which had been thought to be impossible. This article will provide information about the importance of 'dialogue' for decontamination, how engagement of the experts gave members of the PTA and the local community a feeling of 'security and safety', and how the decontamination work was an ever-expanding collaborative work of a large number of people.
Improvement in ultraviolet based decontamination rate using meta-materials
NASA Astrophysics Data System (ADS)
Enaki, Nicolae A.; Bazgan, Sergiu; Ciobanu, Nellu; Turcan, Marina; Paslari, Tatiana; Ristoscu, Carmen; Vaseashta, Ashok; Mihailescu, Ion N.
2017-09-01
We propose a method of decontamination using photon-crystals consisting of microspheres and fiber optics structures with various geometries. The efficient decontamination using the surface of the evanescent zone of meta-materials opens a new perspective in the decontamination procedures. We propose different topological structures of meta-materials to increase the contact surface of UV radiation with contaminated liquid. Recent observation of the trapping of dielectric particles along the fibers help us propose a new perspective on the new possibilities to trap the viruses, bacteria and other microorganisms from liquids, in this special zone, where the effective UV coherent Raman decontamination becomes possible. The nonlinear theory of the excitation of vibration modes of bio-molecule of viruses and bacteria is revised, taking into consideration the bimodal coherent states in coherent Raman excitation of biomolecules.
Athiban, Prakash P; Borthakur, Bikash Jyoti; Ganesan, S; Swathika, B
2012-07-01
The aim of this study was to evaluate the antimicrobial efficacy of Aloe vera and to determine its effectiveness in decontaminating gutta percha cones. A concentrated extract of Aloe vera was used to check for the antimicrobial efficacy using the agar well diffusion method. Presence of zones' of diffusion was identified against three common GP contaminants namely, E.coli, E.faecalis and Staph. aureus. New GP Cones, freshly taken out of the packet were then decontaminated for 1minute using Aloe vera gel and then placed in thioglycolate broth to check for the presence of turbidity. The zones of inhibition on the agar plate were measured as 24mm,21mm and 24mm respectively. The broth remained clear even after 48 hours of incubation. We conclude that Aloe vera is indeed effective as a GP decontaminant and it holds a promising future as a medium for storage of GP cones.
Planning guidance for nuclear-power-plant decontamination. [PWR; BWR
DOE Office of Scientific and Technical Information (OSTI.GOV)
Munson, L.F.; Divine, J.R.; Martin, J.B.
1983-06-01
Direct and indirect costs of decontamination are considered in the benefit-cost analysis. A generic form of the benefit-cost ratio is evaluated in monetary and nonmonetary terms, and values of dollar per man-rem are cited. Federal and state agencies that may have jurisiction over various aspects of decontamination and waste disposal activities are identified. Methods of decontamination, their general effectiveness, and the advantages and disadvantages of each are outlined. Dilute or concentrated chemical solutions are usually used in-situ to dissolve the contamination layer and a thin layer of the underlying substrate. Electrochemical techniques are generally limited to components but show highmore » decontamination effectiveness with uniform corrosion. Mechanical agents are particularly appropriate for certain out-of-system surfaces and disassembled parts. These processes are catagorized and specific concerns are discussed. The treatment, storage, and disposal or discharge or discharge of liquid, gaseous, and solid wastes generated during the decontamination process are discussed. Radioactive and other hazardous chemical wastes are considered. The monitoring, treatment, and control of radioactive and nonradioactive effluents, from both routine operations and possible accidents, are discussed. Protecting the health and safety of personnel onsite during decontamination is of prime importance and should be considered in each facet of the decontamination process. The radiation protection philosophy of reducing exposure to levels as low as reasonably achievable should be stressed. These issues are discussed.« less
Kauppinen, Ari; Ikonen, Jenni; Pursiainen, Anna; Pitkänen, Tarja; Miettinen, Ilkka T
2012-09-01
A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on biofilms was followed as heterotrophic plate counts (HPC) and total cell counts (TCC). Real-time quantitative polymerase chain reaction (qPCR) was used to determine AdV40 and plate counting was used to enumerate E. coli. PAA and chlorine proved to be effective decontaminants since they decreased the levels of AdV40 and E. coli to below method detection limits in both water and biofilms. However, without decontamination, AdV40 remained present in the pipelines for up to 4 days. In contrast, the concentration of cultivable E. coli decreased rapidly in the control pipelines, implying that E. coli may be an inadequate indicator for the presence of viral pathogens. Biofilms responded to the decontaminants by decreased HPCs while TCC remained stable. This indicates that the mechanism of pipeline decontamination by chlorine and PAA is inactivation rather than physical removal of microbes.
Gravett, M R; Hopkins, F B; Self, A J; Webb, A J; Timperley, C M; Riches, J R
2014-08-01
In the event of alleged use of organophosphorus nerve agents, all kinds of environmental samples can be received for analysis. These might include decontaminated and charred matter collected from the site of a suspected chemical attack. In other scenarios, such matter might be sampled to confirm the site of a chemical weapon test or clandestine laboratory decontaminated and burned to prevent discovery. To provide an analytical capability for these contingencies, we present a preliminary investigation of the effect of accelerant-based fire and liquid decontamination on soil contaminated with the nerve agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). The objectives were (a) to determine if VX or its degradation products were detectable in soil after an accelerant-based fire promoted by aviation fuel, including following decontamination with Decontamination Solution 2 (DS2) or aqueous sodium hypochlorite, (b) to develop analytical methods to support forensic analysis of accelerant-soaked, decontaminated and charred soil and (c) to inform the design of future experiments of this type to improve analytical fidelity. Our results show for the first time that modern analytical techniques can be used to identify residual VX and its degradation products in contaminated soil after an accelerant-based fire and after chemical decontamination and then fire. Comparison of the gas chromatography-mass spectrometry (GC-MS) profiles of VX and its impurities/degradation products from contaminated burnt soil, and burnt soil spiked with VX, indicated that the fire resulted in the production of diethyl methylphosphonate and O,S-diethyl methylphosphonothiolate (by an unknown mechanism). Other products identified were indicative of chemical decontamination, and some of these provided evidence of the decontaminant used, for example, ethyl 2-methoxyethyl methylphosphonate and bis(2-methoxyethyl) methylphosphonate following decontamination with DS2. Sample preparation procedures and analytical methods suitable for investigating accelerant and decontaminant-soaked soil samples are presented. VX and its degradation products and/or impurities were detected under all the conditions studied, demonstrating that accelerant-based fire and liquid-based decontamination and then fire are unlikely to prevent the retrieval of evidence of chemical warfare agent (CWA) testing. This is the first published study of the effects of an accelerant-based fire on a CWA in environmental samples. The results will inform defence and security-based organisations worldwide and support the verification activities of the Organisation for the Prohibition of Chemical Weapons (OPCW), winner of the 2013 Nobel Peace Prize for its extensive efforts to eliminate chemical weapons.
Raber, Ellen; Burklund, Alison
2010-01-01
Five parameters were evaluated with surrogates of Bacillus anthracis spores to determine effective decontamination alternatives for use in a contaminated drinking water supply. The parameters were as follows: (i) type of Bacillus spore surrogate (B. thuringiensis or B. atrophaeus), (ii) spore concentration in suspension (102 and 106 spores/ml), (iii) chemical characteristics of the decontaminant (sodium dichloro-S-triazinetrione dihydrate [Dichlor], hydrogen peroxide, potassium peroxymonosulfate [Oxone], sodium hypochlorite, and VirkonS), (iv) decontaminant concentration (0.01% to 5%), and (v) exposure time to decontaminant (10 min to 1 h). Results from 138 suspension tests with appropriate controls are reported. Hydrogen peroxide at a concentration of 5% and Dichlor or sodium hypochlorite at a concentration of 2% were highly effective at spore inactivation regardless of spore type tested, spore exposure time, or spore concentration evaluated. This is the first reported study of Dichlor as an effective decontaminant for B. anthracis spore surrogates. Dichlor's desirable characteristics of high oxidation potential, high level of free chlorine, and a more neutral pH than that of other oxidizers evaluated appear to make it an excellent alternative. All three oxidizers were effective against B. atrophaeus spores in meeting the EPA biocide standard of greater than a 6-log kill after a 10-min exposure time and at lower concentrations than typically reported for biocide use. Solutions of 5% VirkonS and Oxone were less effective as decontaminants than other options evaluated in this study and did not meet the EPA's efficacy standard for a biocide, although they were found to be as effective for concentrations of 102 spores/ml. Differences in methods and procedures reported by other investigators make quantitative comparisons among studies difficult. PMID:20709855
de Vries-Hospers, H G; Sleijfer, D T; Mulder, N H; van der Waaij, D; Neiweg, H O; van Saene, H K
1981-01-01
We describe the bacteriological results of a controlled clinical trial of selective decontamination of the digestive tract as a method of infection prevention in granulocytopenic patients. Selective elimination of Enterobacteriaceae and Pseudomonadaceae species was accomplished by the oral administration of nalidixic acid, co-trimoxazole, or polymyxin. Yeasts were eliminated selectively by amphotericin B or nystatin treatment. The drugs used in this study were chosen because of their capacities to selectively eliminate gram-negative rods and yeast without affecting the anaerobic part of the gut flora which is responsible for colonization resistance. Compared with the control group, the selectively decontaminated patients had significantly fewer (P less than 0.0005) gram-negative rods or yeasts or both in their throat swab cultures and in their feces. This reduction may explain the clinical effectiveness of selective decontamination. PMID:7027923
NASA Astrophysics Data System (ADS)
Ioanid, E. G.; Dunca, S.; Rusu, D.; Tǎnase, C.
2012-04-01
Documents decontamination using dry methods, less invasive than the wet ones implying toxic nocuous substances for cellulose-based materials, has been the object of numerous studies. In recent years mixed researchers teams have been studying the possibility of one-step document decontamination performed by a dry treatment, the risks of repeated wet manipulation thus being reduced. Among physical methods appropriate to this end, high-frequency cold plasma and corona effect can be mentioned. Our studies were carried out on samples taken from ancient books with no cultural heritage value. The decontamination efficiency and the impact on paper of the two types of treatments were determined by: microbiological analysis, scanning electron microscopy, FTIR, chromatic alterations and gloss determination. The above-mentioned procedures eliminate the use of chemical conservation substances, nocuous for the paper support. At the same time the health risk for conservators, restorers, archivists or archive's users is removed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demmer, Rick; Boxall, Colin
Radiological decontamination is an essential enterprise that has become more important over the last four decades due to unfortunate accidents and the threat of terrorist actions. Decontamination can be an effective, beneficial alternative for the cleanup of radiological contamination events; however, the costs and benefits need to be balanced against those for complete removal and demolition of contaminated areas or facilities. Demolition and removal are often the first options considered in such circumstances as decontamination may be thought of as slow and costly. Decontamination has advantages, including significant waste reduction over demolition. In areas with buildings of cultural or societalmore » importance, demolition may not be an option. Three decontamination evaluation test series are the focus of this article: SIMCON 1 and 2 (i.e., simulated contamination), and Urban RDD (radiological dispersal device, i.e., a dirty bomb detonation). These test series revealed that different contaminants respond differently during decontamination. This was found to be true with both SIMCON and Urban RDD simulant tests. SIMCON 2 especially demonstrated that chemically different contaminants respond differently to different decontamination methods: cesium appears to be less tenacious (more easily removed) than zirconium using chemical methods. These differences were underscored by the Urban RDD tests where americium and cobalt tended to precipitate on high pH surfaces (such as concrete), making them easier to remove, while cesium and strontium were essentially unaffected by surface pH and were imbibed more strongly into the substrate pore structure. While authorities argue over the contributions of contaminant chemistry and substrate morphology, the clear answer is that each has a contribution to the tenacity of a contaminant. Knowing how these characteristics interact will make us better at decontamination in the field. This knowledge refutes the efforts of perhaps well-meaning marketers to define our decontamination problems by what products they are trying to sell; often a “one size fits all” type approach. Knowing even a little bit about the character of the decontamination problem will save time and money and increase the efficacy of decontamination.« less
α-Conotoxin Decontamination Protocol Evaluation: What Works and What Doesn’t
Turner, Matthew W.; Cort, John R.; McDougal, Owen M.
2017-01-01
Nine publically available biosafety protocols for safely handling conotoxin peptides were tested to evaluate their decontamination efficacy. Circular dichroism (CD) spectroscopy and mass spectrometry (MS) were used to assess the effect of each chemical treatment on the secondary and primary structure of α-CTx MII (L10V, E11A). Of the nine decontamination methods tested, treatment with 1% (m/v) solution of the enzymatic detergent Contrex™ EZ resulted in a 76.8% decrease in α-helical content as assessed by the mean residue ellipticity at 222 nm, and partial peptide digestion was demonstrated using high performance liquid chromatography mass spectrometry (HPLC-MS). Additionally, treatment with 6% sodium hypochlorite (m/v) resulted in 80.5% decrease in α-helical content and complete digestion of the peptide. The Contrex™ EZ treatment was repeated with three additional α-conotoxins (α-CTxs), α-CTxs LvIA, ImI and PeIA, which verified the decontamination method was reasonably robust. These results support the use of either 1% Contrex™ EZ solution or 6% sodium hypochlorite in biosafety protocols for the decontamination of α-CTxs in research laboratories. PMID:28906461
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abrams, W.T.; Cope, A.W.; Orsulak, R.M.
The overall objective of Task 1 was to demonstrate an effective method for removing tenacious corrosion products in a pressurized water reactor steam generator and thus significantly reduce radiation exposure during subsequent maintenance activities. Various decontamination methods were evaluated and a multistep, low concentration chemical process originated by Kraftwerk Union A.G. (KWU) of the Federal Republic of Germany was selected. The process was further developed and tested by C-E and KWU in West Germany and at C-E's facilities in Windsor, Connecticut. C-E designed, fabricated and tested a portable system to apply the process at Millstone Point II. The decontamination ofmore » the primary channel heads of the two Millstone steam generators was performed by C-E and NUSCO during the 1983 refueling shutdown of Millstone Point II plant. Results of the decontamination were very satisfactory. NUSCO determined that a net savings of 3660 man-rem of personnel exposure was realized during the decontamination demonstration and the subsequent maintenance work on the steam generators.« less
In-package inhibition of E. Coli 0157:H7 on bulk Romaine lettuce using cold plasma
USDA-ARS?s Scientific Manuscript database
Dielectric barrier discharge atmospheric cold plasma (ACP) has been investigated as an innovative method for in-package decontamination of fresh produce. However, while data is available for treatment of single leaves, data is lacking for the effect of ACP on the microbial decontamination of bulk le...
Reactive decontamination formulation
Giletto, Anthony [College Station, TX; White, William [College Station, TX; Cisar, Alan J [Cypress, TX; Hitchens, G Duncan [Bryan, TX; Fyffe, James [Bryan, TX
2003-05-27
The present invention provides a universal decontamination formulation and method for detoxifying chemical warfare agents (CWA's) and biological warfare agents (BWA's) without producing any toxic by-products, as well as, decontaminating surfaces that have come into contact with these agents. The formulation includes a sorbent material or gel, a peroxide source, a peroxide activator, and a compound containing a mixture of KHSO.sub.5, KHSO.sub.4 and K.sub.2 SO.sub.4. The formulation is self-decontaminating and once dried can easily be wiped from the surface being decontaminated. A method for decontaminating a surface exposed to chemical or biological agents is also disclosed.
Skin decontamination cream for radiological contaminants: Formulation development and evaluation
Khan, Abdul Wadood; Kotta, Sabna; Rana, Sudha; Ansari, Shahid Husain; Sharma, Rakesh Kumar; Ali, Javed
2013-01-01
Background: Increased use of the radioactive materials in the field of research, medical, nuclear power plant, and industry has increased the risk of accidental exposure. Intentional use of the radioisotopes by terrorist organizations could cause exposure/contamination of a number of the population. In view of the accidental contamination, there is a need to develop self-usable decontamination formulations that could be used immediately after contamination is suspected. Materials and Methods: Present work was planned to optimize and develop self-usable radiation decontamination cream formulation. Various pharmaceutical parameters were characterized. 99mTc-sodium pertechnetate was used as radiocontaminant. Static counts were recorded before and after decontamination using single photon emission computed tomography. Results: Decontamination efficacy of the cream was found to be 42% ± 3% at 0-0.5 h after the exposure. Primary skin irritancy test was satisfactory as no erythema or edema was observed visually after 2 weeks of the formulation application. Conclusion: The decontamination studies proved the potential of EDTA to remove the radiological contaminants effectively. PMID:23799206
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Context: Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. Aim: To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Settings and Design: Lab-simulated working surface materials. Experimental study design. Materials and Methods: Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Statistical Analysis: Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Results: Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Conclusions: Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area. PMID:28680198
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pirro, J.
This report presents the results of a technical assessment of decontamination alternative prepared for the Western New York Nuclear Service Center (WNYNSC). The purpose of the assessment is to determine the recommended method for decontamination of cell surfaces and decontamination and removal of fuel reprocessing cell equipment to permit manual entry into the cells for the installation of waste solidification equipment. The primary cells of interest are the PMC, GPC, and CPC because they offer the largest usable volume for the solidification program. The secondary cells include XC-1, XC-2, XC-3 and the PPC which may be needed to support themore » solidification program. Five decontamination assessments were evaluated (A-E). The assessments included the estimated cost, occupational exposure, duration, manpower, waste volume generated, and final cell radiation levels achieved with the alternative decontamination methods. The methods varied from thorough destructive decontamination to equipment removal without decontamination followed by cell wall and floor decontamination. The recommended method for the primary cells is to utilize the remote manipulators and cranes to the maximum extent possible to decontaminate equipment and cell surfaces remotely, and to remove the equipment for temporary on-site storage. The recommended method for secondary cell decontamination is to remotely decontaminate the cells to the maximum extent possible prior to manned entry for contact-removal of the fuel reprocessing equipment (Assessment D). Assessment A is expected to cost $8,713,500 in 1980 dollars (including a 25% contingency) and will result in an occupational exposure of 180.3 manRem. Assessment D is expected to cost $11,039,800 and will result in an occupational exposure of 259 manRems.« less
Showering effectiveness for human hair decontamination of the nerve agent VX.
Josse, Denis; Wartelle, Julien; Cruz, Catherine
2015-05-05
In this work, our goals were to establish whether hair decontamination by showering one hour post-exposure to the highly toxic organophosphate nerve agent VX was effective, whether it required the addition of a detergent to water and, if it could be improved by using the adsorbent Fuller's Earth (FE) or the Reactive Skin Decontamination Lotion (RSDL) 30 min prior to showering. Hair exposure to VX and decontamination was performed by using an in vitro model. Hair showering led to 72% reduction of contamination. Addition of detergent to water slightly increased the decontamination effectiveness. Hair treatment with FE or RSDL improved the decontamination rate. Combination of FE use and showering, which yielded a decontamination factor of 41, was demonstrated to be the most effective hair decontamination procedure. Hair wiping after showering was shown to contribute to hair decontamination. Altogether, our results highlighted the importance of considering hair decontamination as an important part of body surface decontamination protocols. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Poornejad, Nafiseh; Nielsen, Jeffery J; Morris, Ryan J; Gassman, Jason R; Reynolds, Paul R; Roeder, Beverly L; Cook, Alonzo D
2016-03-01
Engineering whole organs from porcine decellularized extracellular matrix and human cells may lead to a plentiful source of implantable organs. Decontaminating the porcine decellularized extracellular matrix scaffolds is an essential step prior to introducing human cells. However, decontamination of whole porcine kidneys is a major challenge because the decontamination agent or irradiation needs to diffuse deep into the structure to eliminate all microbial contamination while minimizing damage to the structure and composition of the decellularized extracellular matrix. In this study, we compared four decontamination treatments that could be applicable to whole porcine kidneys: 70% ethanol, 0.2% peracetic acid in 1 M NaCl, 0.2% peracetic acid in 4% ethanol, and gamma (γ)-irradiation. Porcine kidneys were decellularized by perfusion of 0.5% (w/v) aqueous solution of sodium dodecyl sulfate and the four decontamination treatments were optimized using segments (n = 60) of renal tissue to ensure a consistent comparison. Although all four methods were successful in decontamination, γ-irradiation was very damaging to collagen fibers and glycosaminoglycans, leading to less proliferation of human renal cortical tubular epithelium cells within the porcine decellularized extracellular matrix. The effectiveness of the other three optimized solution treatments were then all confirmed using whole decellularized porcine kidneys (n = 3). An aqueous solution of 0.2% peracetic acid in 1 M NaCl was determined to be the best method for decontamination of porcine decellularized extracellular matrix. © The Author(s) 2015.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rick Demmer; John Drake; Ryan James, PhD
Over the last 50 years, the study of radiological contamination and decontamination has expanded significantly. This paper addresses the mechanisms of radiological contamination that have been reported and then discusses which methods have recently been used during performance testing of several different decontamination technologies. About twenty years ago the Idaho Nuclear Technology Engineering Center (INTEC) at the INL began a search for decontamination processes which could minimize secondary waste. In order to test the effectiveness of these decontamination technologies, a new simulated contamination, termed SIMCON, was developed. SIMCON was designed to replicate the types of contamination found on stainless steel,more » spent fuel processing equipment. Ten years later, the INL began research into methods for simulating urban contamination resulting from a radiological dispersal device (RDD). This work was sponsored by the Defense Advanced Research Projects Agency (DARPA) and included the initial development an aqueous application of contaminant to substrate. Since 2007, research sponsored by the US Environmental Protection Agency (EPA) has advanced that effort and led to the development of a contamination method that simulates particulate fallout from an Improvised Nuclear Device (IND). The IND method diverges from previous efforts to create tenacious contamination by simulating a reproducible “loose” contamination. Examining these different types of contamination (and subsequent decontamination processes), which have included several different radionuclides and substrates, sheds light on contamination processes that occur throughout the nuclear industry and in the urban environment.« less
Long lasting decontamination foam
Demmer, Ricky L.; Peterman, Dean R.; Tripp, Julia L.; Cooper, David C.; Wright, Karen E.
2010-12-07
Compositions and methods for decontaminating surfaces are disclosed. More specifically, compositions and methods for decontamination using a composition capable of generating a long lasting foam are disclosed. Compositions may include a surfactant and gelatin and have a pH of less than about 6. Such compositions may further include affinity-shifting chemicals. Methods may include decontaminating a contaminated surface with a composition or a foam that may include a surfactant and gelatin and have a pH of less than about 6.
Akchata, Suman; Lavanya, K; Shivanand, Bhushan
2017-01-01
Decontamination of various working surfaces with sodium pertechnetate minor spillage is essential for maintaining good radiation safety practices as well as for regulatory compliance. To observe the influences of decontaminating agents and swipe materials on different type of surfaces used in nuclear medicine laboratory work area wet spilled with 99m-technetium (99mTc) sodium pertechnetate. Lab-simulated working surface materials. Experimental study design. Direct decontamination method on dust-free lab simulated new working surfaces [stainless steel, polyvinyl chloride (PVC), Perspex, resin] using four decontaminating agents [tap water, soap water (SW), Radiacwash, and spirit] with four different swipe material [cotton, tissue paper (TP), Whatman paper (WP), adsorbent sheet (AS)] was taken 10 samples (n = 10) for each group. Parametric test two-way analysis of variance is used with significance level of 0.005, was used to evaluate statistical differences between different group of decontaminating agent and swipe material, and the results are expressed in mean ± SD. Decontamination factor is calculated after five cleaning for each group. A total of 160 samples result calculated using four decontaminating agent (tap water, SW, Radiacwash, and spirit), four swipe material (cotton, TP, WP, and AS) for commonly used surface (stainless steel, PVC, Perspex, resin) using direct method by 10 samples (n = 10) for each group. Tap water is the best decontaminating agent compared with SW, Radiac wash and spirit for the laboratory simulated stainless steel, PVC, and Perspex surface material, whereas in case of resin surface material, SW decontaminating agent is showing better effectiveness. Cotton is the best swipe material compared to WP-1, AS and TP for the stainless steel, PVC, Perspex, and resin laboratory simulated surface materials. Perspex and stainless steel are the most suitable and recommended laboratory surface material compared to PVC and resin in nuclear medicine. Radiacwash may show better result for 99mTc labelled product and other radionuclide contamination on the laboratory working surface area.
NASA Astrophysics Data System (ADS)
Machhour, Hasna; El Hadrami, Ismail; Imziln, Boujamaa; Mouhib, Mohamed; Mahrouz, Mostafa
2011-04-01
Peppermint was inoculated with Escherichia coli and its decontamination was carried out by gamma irradiation at low irradiation doses (0.5, 1.0 and 2.66 kGy). The efficiency of this decontamination method was evaluated and its impact on the quality parameters of peppermint, such as the color and ash content, as well as the effect on fingerprint components such as phenols and essential oils, was studied. Gas chromatography coupled to mass spectrometry (GC/MS) and High Performance Liquid Chromatography (HPLC) were used to characterize essential oils and phenolic compounds, respectively. The results indicated a complete decontamination of peppermint after the low dose gamma irradiation without a significant loss in quality attributes.
Mycotoxin Decontamination of Food: Cold Atmospheric Pressure Plasma versus “Classic” Decontamination
Hojnik, Nataša; Cvelbar, Uroš; Tavčar-Kalcher, Gabrijela; Walsh, James L.; Križaj, Igor
2017-01-01
Mycotoxins are secondary metabolites produced by several filamentous fungi, which frequently contaminate our food, and can result in human diseases affecting vital systems such as the nervous and immune systems. They can also trigger various forms of cancer. Intensive food production is contributing to incorrect handling, transport and storage of the food, resulting in increased levels of mycotoxin contamination. Mycotoxins are structurally very diverse molecules necessitating versatile food decontamination approaches, which are grouped into physical, chemical and biological techniques. In this review, a new and promising approach involving the use of cold atmospheric pressure plasma is considered, which may overcome multiple weaknesses associated with the classical methods. In addition to its mycotoxin destruction efficiency, cold atmospheric pressure plasma is cost effective, ecologically neutral and has a negligible effect on the quality of food products following treatment in comparison to classical methods. PMID:28452957
Hojnik, Nataša; Cvelbar, Uroš; Tavčar-Kalcher, Gabrijela; Walsh, James L; Križaj, Igor
2017-04-28
Mycotoxins are secondary metabolites produced by several filamentous fungi, which frequently contaminate our food, and can result in human diseases affecting vital systems such as the nervous and immune systems. They can also trigger various forms of cancer. Intensive food production is contributing to incorrect handling, transport and storage of the food, resulting in increased levels of mycotoxin contamination. Mycotoxins are structurally very diverse molecules necessitating versatile food decontamination approaches, which are grouped into physical, chemical and biological techniques. In this review, a new and promising approach involving the use of cold atmospheric pressure plasma is considered, which may overcome multiple weaknesses associated with the classical methods. In addition to its mycotoxin destruction efficiency, cold atmospheric pressure plasma is cost effective, ecologically neutral and has a negligible effect on the quality of food products following treatment in comparison to classical methods.
Sorption of Radionuclides to Building Materials and its ...
Journal article Urban contamination via a number of radiological release scenarios may require simple decontamination methods that can be deployed for wide-area decontamination. This paper investigates a number of factors of importance for developing such decontamination methods, focusing on cesium.
Kaminski, Michael D; Lee, Sang Don; Magnuson, Matthew
2016-03-15
Nuclear or radiological terrorism in the form of uncontrolled radioactive contamination presents a unique challenge in the field of nuclear decontamination. Potential targets require an immediate decontamination response, or mitigation plan to limit the social and economic impact. To date, experience with urban decontamination of building materials - specifically hard, porous, external surfaces - is limited to nuclear weapon fallout and nuclear reactor accidents. Methods are lacking for performing wide-area decontamination in an urban environment so that in all release scenarios the area may be re-occupied without evaluation and/or restriction. Also lacking is experience in developing mitigation strategies, that is, methods of mitigating contamination and its resultant radiation dose in key areas during the immediate aftermath of an event and after lifesaving operations. To date, the tremendous strategy development effort primarily by the European community has focused on the recovery phase, which extends years beyond the release event. In this review, we summarize the methods and data collected over the past 70 years in the field of hard, external surface decontamination of radionuclide contaminations, with emphasis on methods suitable for response to radiological dispersal devices and their potentially unique physico-chemical characteristics. This review concludes that although a tremendous amount of work has been completed primarily by the European Community (EU) and the United Kingdom (UK), the few studies existing on each technique permit only very preliminary estimates of decontamination factors for various building materials and methods and extrapolation of those values for use in environments outside the EU and UK. This data shortage prevents us from developing an effective and detailed mitigation response plan and remediation effort. Perhaps most importantly, while the data available does include valuable information on the practical aspects of performing the various remediation methods including costs, coverage rates, manpower, pitfalls, etc., it lacks the details on lessons learned, best practices, and standard procedures, for instance, that would be required to develop a mitigation strategy. While the urban decontamination problem is difficult and there is much more research to do, the existing literature provides a framework for a response plan. Using this framework, in conjunction with computer modeling and relevant data collection, can lead to development of appropriate plans and exercises that would permit development of a mitigation and remediation response. Copyright © 2015 Elsevier B.V. All rights reserved.
Zuidberg, Matthijs C; van Woerkom, Tiest; de Bruin, Karla G; Stoel, Reinoud D; de Puit, Marcel
2014-01-01
Following a CBRN incident, first responders use decontamination procedures to reduce the risk of exposure. The effect of decontamination on forensic trace material has, however, not been fully examined. This study sought to evaluate the effect of five different physical or chemical decontamination materials on the recovery of latent fingerprints. Fingerprints were deposited on glass slides, decontaminated, and assessed on the presence of ridge detail. The results demonstrate that decontamination affects the quality of latent fingerprints substantially. On at least 61% of the fingerprints, a reduced amount of ridge detail was observed upon decontamination. Furthermore, development with cyanoacrylate appeared not to succeed anymore. Instead, the ability of vacuum metal deposition to successfully develop decontaminated fingerprints is demonstrated. The results from this study may contribute to an increased forensic awareness regarding decontamination and emphasize the necessity for further research into new item decontamination procedures or new forensic initiatives prior to decontamination. © 2013 American Academy of Forensic Sciences.
The feasibility study of hot cell decontamination by the PFC spray method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hui-Jun Won; Chong-Hun Jung; Jei-Kwon Moon
2008-01-15
The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to bemore » reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is developing dry decontamination technologies applicable to a decontamination of a highly radioactive area loosely contaminated with radioactive particles. This contamination has occurred as a result of an examination of a post-irradiated material or the development of the DUPIC process. The dry decontamination technologies developed are the carbon dioxide pellet spray method and the PFC spray method. As a part of the project, PFC ultrasonic decontamination technology was developed in 2004. The PFC spray decontamination method which is based on the test results of the PFC ultrasonic method has been under development since 2005. The developed PFC spray decontamination equipment consists of four modules (spray, collection, filtration and distillation). Vacuum cup of the collection module gathers the contaminated PFC solution, then the solution is moved to the filtration module and it is recycled. After a multiple recycling of the spent PFC solution, it is purified in the distillation module. A performance test on each module was executed and the results have been reported. A combined test of the four modules, however, has not been performed as yet. The main objective of the present study is to demonstrate the feasibility of the full PFC spray decontamination process. Decontamination of the inside of the IMEF hot cell by the PFC spray method was also performed. PFC spray decontamination process was demonstrated by using a surrogate wall contaminated with Eu{sub 2}O{sub 3} powder. The spray pressure was 41 kgf/cm{sup 2}, the orifice diameter was 0.2 mm and the spray velocity was 0.2 L/min. And, the decontaminated area was 100 cm{sup 2}. From previous test results, we found that the decontamination factor of the PFC spray method was in the range from 9.6 to 62.4. When the decontamination efficiency of Co-60 was high, then the decontamination efficiency of Cs-137 was also high. As the surface roughness of the specimen increased, the PFC spray decontamination efficiency decreased. Inferring from the previous results, the surface of the surrogate wall was cleaned by the PFC spray method. The vacuum cup of the collection module operated well and gathered more than 99 % of the PFC solution. Also, filtration and distillation modules operated well. All the filtered PFC solution flowed to the storage chamber where some of the PFC solution was distilled. The coolant of the distillation module was a dry ice. And, the recycled solution was transferred to the spray module by a high pressure pump. To evaluate the PFC spray decontamination efficiency, a smear device was fabricated and operated by a manipulator. Before and after decontamination, a smear test was performed. The tested area was 100 cm{sup 2} and the radioactivity was estimated indirectly by measuring the radioactivity of the filter paper. The average decontamination factor was in the range between 10 and 15. One application time was 2 minutes. The sprayed PFC solution was collected by the vacuum cup and it was stored in the collection equipment. After the termination of the decontamination test, the flexible hose was cut near a toboggan. The collection equipment that contained the spent PFC solution, vacuum cup, spray nozzle and the flexible hose was stored in a radioactive waste storage tank. A feasibility study for the PFC spray decontamination method for an application to a hot cell surface was performed. The decontamination equipment that consisted of four modules operated well in the hot cell. The collection module gathered the sprayed PFC solution. The solution was purified in the filtration or distillation modules. The main characteristic of the distillation module is the use of dry ice as a coolant. The decontamination factor of IMEF hot cell was in the range from 10 to 15. It was difficult to measure the radioactivity accurately at a given time. We, however, concluded that the PFC spray decontamination method is a promising technology. It generated a small amount of secondary waste and used a non-toxic and non-conducting material. Decontamination work was performed with a little loss of the main decontamination agent. Based on the test results, we are developing an improved PFC spray decontamination process.« less
α-Conotoxin Decontamination Protocol Evaluation: What Works and What Doesn’t
Turner, Matthew; Cort, John; McDougal, Owen
2017-09-14
Nine publically available biosafety protocols for safely handling conotoxin peptides were tested to evaluate their decontamination efficacy. Circular dichroism (CD) spectroscopy and mass spectrometry (MS) were used to assess the effect of each chemical treatment on the secondary and primary structure of α-CTx MII [L10V, E11A]. Of the nine decontamination methods tested, treatment with 1% (m/v) solution of the enzymatic detergent Contrex™ EZ resulted in a 76.8% decrease in α-helical content as assessed by the mean residue ellipticity at 222 nm, and partial peptide digestion was demonstrated using high performance liquid chromatography mass spectrometry (HPLC-MS). Additionally, treatment with 6% sodiummore » hypochlorite (m/v) resulted in 80.5% decrease in α-helical content and complete digestion of the peptide. The Contrex™ EZ treatment was repeated with three additional α-conotoxins (α-CTxs), α-CTxs LvIA, ImI and PeIA, which verified the decontamination method was reasonably robust. These results support the use of either 1% Contrex™ EZ solution or 6% sodium hypochlorite in biosafety protocols for the decontamination of α- CTxs in research laboratories.« less
α-Conotoxin Decontamination Protocol Evaluation: What Works and What Doesn’t
DOE Office of Scientific and Technical Information (OSTI.GOV)
Turner, Matthew; Cort, John; McDougal, Owen
Nine publically available biosafety protocols for safely handling conotoxin peptides were tested to evaluate their decontamination efficacy. Circular dichroism (CD) spectroscopy and mass spectrometry (MS) were used to assess the effect of each chemical treatment on the secondary and primary structure of α-CTx MII [L10V, E11A]. Of the nine decontamination methods tested, treatment with 1% (m/v) solution of the enzymatic detergent Contrex™ EZ resulted in a 76.8% decrease in α-helical content as assessed by the mean residue ellipticity at 222 nm, and partial peptide digestion was demonstrated using high performance liquid chromatography mass spectrometry (HPLC-MS). Additionally, treatment with 6% sodiummore » hypochlorite (m/v) resulted in 80.5% decrease in α-helical content and complete digestion of the peptide. The Contrex™ EZ treatment was repeated with three additional α-conotoxins (α-CTxs), α-CTxs LvIA, ImI and PeIA, which verified the decontamination method was reasonably robust. These results support the use of either 1% Contrex™ EZ solution or 6% sodium hypochlorite in biosafety protocols for the decontamination of α- CTxs in research laboratories.« less
Piroth, Tobias; Pauly, Marie-Christin; Schneider, Christian; Wittmer, Annette; Möllers, Sven; Döbrössy, Máté; Winkler, Christian; Nikkhah, Guido
2014-01-01
Restorative cell therapy concepts in neurodegenerative diseases are aimed at replacing lost neurons. Despite advances in research on pluripotent stem cells, fetal tissue from routine elective abortions is still regarded as the only safe cell source. Progenitor cells isolated from distinct first-trimester fetal CNS regions have already been used in clinical trials and will be used again in a new multicenter trial funded by the European Union (TRANSEURO). Bacterial contamination of human fetal tissue poses a potential risk of causing infections in the brain of the recipient. Thus, effective methods of microbial decontamination and validation of these methods are required prior to approval of a neurorestorative cell therapy trial. We have developed a protocol consisting of subsequent washing steps at different stages of tissue processing. Efficacy of microbial decontamination was assessed on rat embryonic tissue incubated with high concentrations of defined microbe solutions including representative bacterial and fungal species. Experimental microbial contamination was reduced by several log ranks. Subsequently, we have analyzed the spectrum of microbial contamination and the effect of subsequent washing steps on aborted human fetal tissue; 47.7% of the samples taken during human fetal tissue processing were positive for a microbial contamination, but after washing, no sample exhibited bacterial growth. Our data suggest that human fetal tissue for neural repair can carry microbes of various species, highlighting the need for decontamination procedures. The decontamination protocol described in this report has been shown to be effective as no microbes could be detected at the end of the procedure.
In vivo decontamination of the nerve agent VX using the domestic swine model.
Misik, Jan; Pavlik, Michal; Novotny, Ladislav; Pavlikova, Ruzena; Chilcott, Robert P; Cabal, Jiri; Kuca, Kamil
2012-11-01
The purpose of this in vivo study was to assess a new, putatively optimised method for mass casualty decontamination ("ORCHIDS protocol") for effectiveness in removing the chemical warfare agent VX from the skin of anaesthetised, domestic white pigs. ORCHIDS protocol consists of a 1.5-minute shower with a mild detergent (Argos™) supplemented by physical removal. A standard method of wet decontamination was used for comparison. Experimental animals were divided into four groups (A-D). Two groups were exposed to a supra-lethal percutaneous dose (5 × LD(50); 300 μg kg(-1)) of VX for 1 h prior to decontamination with either the ORCHIDS (C) or standard protocol (D). A third (B, positive control) group was exposed but not subject to decontamination. Blank controls (A) received anaesthesia and the corresponding dose of normal saline instead of VX. Observations of the clinical signs of intoxication were supplemented by measurements of whole blood cholinesterase (ChE) performed on samples of arterial blood acquired at 30-minute intervals for the duration of the study (up to 6 h). Untreated (B) animals displayed typical cholinergic signs consistent with VX intoxication (local fasciculation, mastication, salivation, pilo-erection and motor convulsions) and died 165-240 min post exposure. All animals in both decontamination treatment groups (C, D) survived the duration of the study and exhibited less severe signs of cholinergic poisoning. Thus, both the standard and ORCHIDS protocol were demonstrably effective against exposure to the potent nerve agent VX, even after a delay of 1 h. A critical advantage of the ORCHIDS protocol is the relatively short shower duration (1½ min compared to 3 min). In practice, this could substantially improve the rate at which individuals could be decontaminated by emergency responders following exposure to toxic materials such as chemical warfare agents.
An evaluation of selected methods for the decontamination of cattle hides prior to skinning.
Small, A; Wells-Burr, B; Buncic, S
2005-02-01
The effectiveness of different decontamination treatments in reducing microbial loads on cattle hides was assessed. The 10-s hide treatments were conducted using a wet-and-dry vacuum cleaner filled with one of the liquids (heated to 50 °C) indicated below, followed or not by 10-min drying in the air. Also, the hide was clipped, followed or not by 10-s singeing using a hand-held blowtorch. Before and after each decontamination treatment, the hide was sampled (100 cm(2) areas) by a sponge-swabbing method to compare the total viable counts of bacteria (TVC). The largest bacterial reduction (P<0.001; 2.31log(10) cfu/cm(2)) was achieved by singeing of previously clipped hide. Treatment of hide with a food industry sanitizer solution (10% Betane Plus) resulted in significant reductions of 1.80 (P<0.001) and 1.98log(10) cfu/cm(2) (P<0.001) without and with subsequent drying, respectively. Treatment of hide with a food industry disinfectant (P3-Topactive DES) significantly reduced TVC by 0.97 (P<0.001) and 1.18log(10) cfu/cm(2) (P<0.001) without and with subsequent drying, respectively. Treatments of hide with water alone or with a food-safe detergent solution (Formula 963B), or hide clipping alone, did not produce significant decontamination effects. Since hide contamination is associated with microbial contamination of the carcasses, the results indicate that post-killing/pre-skinning hide decontamination (used alone, or in combination with carcass decontamination) has a potential to improve microbial meat safety. Nevertheless, further research is required to optimise the efficacy of these treatments in the reduction of specific pathogens under commercial conditions.
Xu, Jiawen; Wu, Cuiyu; Deng, Jianbin; Liao, Wenwei; Ling, Yuxiang; Yang, Yuanxiu; Zhao, Yina; Zhao, Yunlin; Hu, Xi; Wang, Hui; Liu, Yunguo
2017-01-01
A method for grafting ethylenediamine to a magnetic graphene oxide composite (EDA-GO@Fe3O4) was developed for Cr(VI) decontamination. The physicochemical properties of EDA-GO@Fe3O4 were characterized using HRTEM, EDS, FT-IR, TG-DSC, and XPS. The effects of pH, sorbent dose, foreign anions, time, Cr(VI) concentration, and temperature on decontamination process were studied. The solution pH can largely affect the decontamination process. The pseudo-second-order model is suitable for being applied to fit the adsorption processes of Cr(VI) with GO@Fe3O4 and EDA-GO@Fe3O4. The intra-particle diffusion is not the rate-controlling step. Isotherm experimental data can be described using the Freundlich model. The effects of multiple factors on the Cr(VI) decontamination was investigated by a 25−1 fractional factorial design (FFD). The adsorption process can significantly be affected by the main effects of A (pH), B (Cr(VI) concentration), and E (Adsorbent dose). The combined factors of AB (pH × Cr(VI) concentration), AE (pH × Adsorbent dose), and BC (Cr(VI) concentration × Temperature) had larger effects than other factors on Cr(VI) removal. These results indicated that EDA-GO@Fe3O4 is a potential and suitable candidate for treatment of heavy metal wastewater. PMID:29084287
NASA Astrophysics Data System (ADS)
Migdal, W.; Owczarczyk, B.; Kedzia, B.; Holderna-Kedzia, E.; Segiet-Kujawa, E.
1998-06-01
Several thousand tons of medical herbs are produced annually by pharmaceutical industry in Poland. This product should be of highest quality and microbial purity. Recently, chemical methods of decontamination are recognized as less safe, thus irradiation technique was chosen to replace them in use. In the Institute of Nuclear Chemistry and Technology the national program on the application of irradiation to the decontamination of medical herbs is in progress now. The purpose of the program is to elaborate, on the basis of research work, the facility standards and technological instructions indispensable for the practice of radiation technology.
Public experiences of mass casualty decontamination.
Carter, Holly; Drury, John; Rubin, G James; Williams, Richard; Amlôt, Richard
2012-09-01
In this article, we analyze feedback from simulated casualties who took part in field exercises involving mass decontamination, to gain an understanding of how responder communication can affect people's experiences of and compliance with decontamination. We analyzed questionnaire data gathered from 402 volunteers using the framework approach, to provide an insight into the public's experiences of decontamination and how these experiences are shaped by the actions of emergency responders. Factors that affected casualties' experiences of the decontamination process included the need for greater practical information and better communication from responders, and the need for privacy. Results support previous findings from small-scale incidents that involved decontamination in showing that participants wanted better communication from responders during the process of decontamination, including more practical information, and that the failure of responders to communicate effectively with members of the public led to anxiety about the decontamination process. The similarity between the findings from the exercises described in this article and previous research into real incidents involving decontamination suggests that field exercises provide a useful way to examine the effect of responder communication strategies on the public's experiences of decontamination. Future exercises should examine in more detail the effect of various communication strategies on the public's experiences of decontamination. This will facilitate the development of evidence-based communication strategies intended to reduce anxiety about decontamination and increase compliance among members of the public during real-life incidents that involve mass decontamination.
[Advances in peroxide-based decontaminating technologies].
Xi, Hai-ling; Zhao, San-ping; Zhou, Wen
2013-05-01
With the boosting demand for eco-friendly decontaminants, great achievements in peroxide-based decontaminating technologies have been made in recent years. These technologies have been applied in countering chemical/biological terrorist attacks, dealing with chemical/biological disasters and destructing environmental pollutants. Recent research advances in alpha-nucleophilic/oxidative reaction mechanisms of peroxide-based decontamination against chemical warfare agents were reviewed, and some classical peroxide-based decontaminants such as aqueous decontaminating solution, decontaminating foam, decontaminating emulsions, decontaminating gels, decontaminating vapors, and some newly developed decontaminating media (e.g., peroxide-based self-decontaminating materials and heterogeneous nano-catalytic decontamination systems) were introduced. However, currently available peroxide-based decontaminants still have some deficiencies. For example, their decontamination efficiencies are not as high as those of chlorine-containing decontaminants, and some peroxide-based decontaminants show relatively poor effect against certain agents. More study on the mechanisms of peroxide-based decontaminants and the interfacial interactions in heterogeneous decontamination media is suggested. New catalysts, multifunctional surfactants, self-decontaminating materials and corrosion preventing technologies should be developed before peroxide-based decontaminants really become true "green" decontaminants.
Percutaneous toxicity and decontamination of soman, VX, and paraoxon in rats using detergents.
Misík, Jan; Pavliková, Růžena; Kuča, Kamil
2013-06-01
Highly toxic organophosphorus compounds (OPs) were originally developed for warfare or as agricultural pesticides. Today, OPs represent a serious threat to military personnel and civilians. This study investigates the in vivo decontamination of male Wistar rats percutaneously exposed to paraoxon and two potent nerve agents--soman (GD) and VX. Four commercial detergents were tested as decontaminants--Neodekont(TM), Argos(TM), Dermogel(TM), and FloraFree(TM). Decontamination performed 2 min after exposure resulted in a higher survival rate in comparison with non-decontaminated controls. The decontamination effectiveness was expressed as protective ratio (PR, median lethal dose of agent in decontaminated animals divided by the median lethal dose of agent in untreated animals). The highest decontamination effectiveness was consistently achieved with Argos(TM) (PR=2.3 to 64.8), followed by Dermogel(TM) (PR=2.4 to 46.1). Neodekont(TM) and FloraFree(TM) provided the lowest decontamination effectiveness, equivalent to distilled water (PR=1.0 to 43.2).
Buhr, T L; Young, A A; Barnette, H K; Minter, Z A; Kennihan, N L; Johnson, C A; Bohmke, M D; DePaola, M; Cora-Laó, M; Page, M A
2015-11-01
To develop test methods and evaluate survival of Bacillus anthracis ∆Sterne or Bacillus thuringiensis Al Hakam on materials contaminated with dirty spore preparations after exposure to hot, humid air using response surface modelling. Spores (>7 log10 ) were mixed with humic acid + spent sporulation medium (organic debris) or kaolin (dirt debris). Spore samples were then dried on five different test materials (wiring insulation, aircraft performance coating, anti-skid, polypropylene, and nylon). Inoculated materials were tested with 19 test combinations of temperature (55, 65, 75°C), relative humidity (70, 80, 90%) and time (1, 2, 3 days). The slowest spore inactivation kinetics was on nylon webbing and/or after addition of organic debris. Hot, humid air effectively decontaminates materials contaminated with dirty Bacillus spore preparations; debris and material interactions create complex decontamination kinetic patterns; and B. thuringiensis Al Hakam is a realistic surrogate for B. anthracis. Response surface models of hot, humid air decontamination were developed which may be used to select decontamination parameters for contamination scenarios including aircraft. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Ardizzoni, E; Mulders, W; Sanchez-Padilla, E; Varaine, F; de Jong, B C; Rigouts, L
2014-08-01
Long transportation times of samples to culture laboratories can lead to higher contamination rates and significant loss of viability, resulting in lower culture positivity rates. Thin-layer agar (TLA) is a sensitive culture method for the isolation of Mycobacterium tuberculosis that has been optimised with N-acetyl-L-cysteine-sodium hydroxide (NALC-NaOH) decontaminated samples. The combination of the TLA culture method and other decontamination procedures has not been extensively validated. Among 390 smear-positive samples, we compared the culture positivity of samples decontaminated using the Petroff method vs. NALC-NaOH neutralised with phosphate buffer (PBS), applied to samples preserved with cetylpyridinium chloride (CPC) or CPC-free, and then of CPC-preserved samples decontaminated with NALC-NaOH neutralised using Difco neutralising buffer. The sediments were inoculated on TLA, and then on MGIT 960 or Löwenstein-Jensen (LJ) as gold standards. Decontamination with NALC-NaOH yielded higher culture positivity in TLA than in the Petroff method, which was further enhanced by neutralising CPC with the Difco buffer. Surprisingly, culture positivity on LJ also increased after using Difco buffer, suggesting that CPC may not be completely neutralised in egg-based medium. After transportation in CPC, decontamination using NALC-NaOH followed by neutralisation using Difco buffer resulted in the best recovery rates for samples inoculated on TLA and on LJ.
Joosen, M J A; van den Berg, R M; de Jong, A L; van der Schans, M J; Noort, D; Langenberg, J P
2017-04-01
The main goal of the present study was to obtain insight into depot formation and penetration following percutaneous VX poisoning, in order to identify an appropriate decontamination window that can enhance or support medical countermeasures. The study was executed in two phases, using the hairless guinea pig as an animal model. In the first phase the effect of various decontamination regimens on levels of free VX in skin and plasma were studied as well as on blood cholinesterase levels. Animals were exposed to 0.5 mg/kg VX and were not decontaminated (control), decontaminated with RSDL once at 15 or 90 min after exposure or three times at 15, 25 and 35 (10-min interval) or 15, 45 and 75 min after exposure (30-min interval). There was no significant effect of any of the decontamination regimens on the 6-h survival rate of the animals. However, all animals that had been decontaminated 15 min after exposure, showed a survival rate of more than 90%, compared to 50-60% in animals that were not decontaminated or decontaminated at 90 min after exposure. In the second phase of the study, hairless guinea pigs were exposed to 1 mg/kg VX on the shoulder, followed either by decontamination with RSDL (10 min interval), conventional treatment on indication of clinical signs or a combination thereof. It appeared that a thorough, repeated decontamination alone could not save the majority of the animals. A 100% survival rate was observed in the group that received a combination of decontamination and treatment. In conclusion, the effects of VX exposure could be influenced by various RSDL decontamination regimens. The results in freely moving animals showed that skin decontamination, although not fully effective in removing all VX from the skin and skin depot is crucial to support pharmacological intervention. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Chibeu, Andrew; Balamurugan, S
2018-01-01
We describe a method for assessing the effectiveness of tea extract based virucide (TeaF) application to remove phage LISTEX™ P100 not bound to Listeria monocytogenes from stomached rinses prior to direct plating and bacterial enumeration, where the phage is being used as a decontaminant to reduce L. monocytogenes levels on ready-to-eat meat.
Nuclear decontamination technology evaluation to address contamination of a municipal water system
DOE Office of Scientific and Technical Information (OSTI.GOV)
McFee, J.; Langsted, J.; Young, M.
The US Environmental Protection Agency (EPA) and US Department of Homeland Security (DHS) are considering the impact and recovery from contamination of municipal water systems, including intentional contamination of those systems. Industrial chemicals, biological agents, drugs, pesticides, chemical warfare agents, and radionuclides all could be introduced into a municipal water system to create detrimental health effects and disrupt a community. Although unintentional, the 1993 cryptosporidium contamination of the Milwaukee WS water system resulted in 100 fatalities and disrupted the city for weeks. Shaw Environmental and Infrastructure Inc, (Shaw), as a subcontractor on a DHS contract with Michael Baker Jr., Inc.,more » was responsible for evaluation of the impact and recovery from radionuclide contamination in a municipal water system distribution system. Shaw was tasked to develop a matrix of nuclear industry decontamination technologies and evaluate applicability to municipal water systems. Shaw expanded the evaluation to include decontamination methods commonly used in the drinking water supply. The matrix compared all technologies for implementability, effectiveness, and cost. To address the very broad range of contaminants and contamination scenarios, Shaw bounded the problem by identification of specific contaminant release scenario(s) for specific water system architecture(s). A decontamination technology matrix was developed containing fifty-nine decontamination technologies potentially applicable to the water distribution system piping, pumps, tanks, associated equipment, and/or contaminated water. Qualitatively, the majority of the nuclear industry decontamination technologies were eliminated from consideration due to implementability concerns. However, inclusion of the municipal water system technologies supported recommendations that combined the most effective approaches in both industries. (authors)« less
2007-05-10
objective is achieved through consequence management and fixed-site decontamination operations. The effectiveness of CBRN consequence management...decontamination operations. The effectiveness of CBRN consequence management and fixed-site decontamination executed in the Joint Security Area can be...when faced with Chemical, Biological, Radiological, or Nuclear (CBRN) contaminated ports of debarkation. The effectiveness of CBRN consequence
Pruvost, Mélanie; Bennett, E. Andrew; Grange, Thierry; Geigl, Eva-Maria
2010-01-01
Background PCR amplification of minute quantities of degraded DNA for ancient DNA research, forensic analyses, wildlife studies and ultrasensitive diagnostics is often hampered by contamination problems. The extent of these problems is inversely related to DNA concentration and target fragment size and concern (i) sample contamination, (ii) laboratory surface contamination, (iii) carry-over contamination, and (iv) contamination of reagents. Methodology/Principal Findings Here we performed a quantitative evaluation of current decontamination methods for these last three sources of contamination, and developed a new procedure to eliminate contaminating DNA contained in PCR reagents. We observed that most current decontamination methods are either not efficient enough to degrade short contaminating DNA molecules, rendered inefficient by the reagents themselves, or interfere with the PCR when used at doses high enough to eliminate these molecules. We also show that efficient reagent decontamination can be achieved by using a combination of treatments adapted to different reagent categories. Our procedure involves γ- and UV-irradiation and treatment with a mutant recombinant heat-labile double-strand specific DNase from the Antarctic shrimp Pandalus borealis. Optimal performance of these treatments is achieved in narrow experimental conditions that have been precisely analyzed and defined herein. Conclusions/Significance There is not a single decontamination method valid for all possible contamination sources occurring in PCR reagents and in the molecular biology laboratory and most common decontamination methods are not efficient enough to decontaminate short DNA fragments of low concentration. We developed a versatile multistrategy decontamination procedure for PCR reagents. We demonstrate that this procedure allows efficient reagent decontamination while preserving the efficiency of PCR amplification of minute quantities of DNA. PMID:20927390
Bello, Dhimiter; Woskie, Susan R; Streicher, Robert P; Stowe, Meredith H; Sparer, Judy; Redlich, Carrie A; Cullen, Mark R; Liu, Youcheng
2005-07-01
Isocyanates may cause contact dermatitis and respiratory sensitization leading to asthma. Dermal exposure to aliphatic isocyanates in auto body shops is very common. However, little is known about the effectiveness of available commercial products used for decontaminating aliphatic polyisocyanates. This experimental study evaluated the decontamination effectiveness of aliphatic polyisocyanates for several skin and surface decontaminants available for use in the auto body industry. The efficiency of two major decontamination mechanisms, namely (i) consumption of free isocyanate groups via chemical reactions with active hydrogen components of the decontaminant and (ii) physical removal processes such as dissolution were studied separately for each decontaminant. Considerable differences were observed among surface decontaminants in their rate of isocyanate consumption, of which those containing free amine groups performed the best. Overall, Pine-Sol(R) MEA containing monoethanolamine was the most efficient surface decontaminant, operating primarily via chemical reaction with the isocyanate group. Polypropylene glycol (PPG) had the highest physical removal efficiency and the lowest reaction rate with isocyanates. All tested skin decontaminants performed similarly, accomplishing decontamination primarily via physical processes and removing 70-80% of isocyanates in one wiping. Limitations of these skin decontaminants are discussed and alternatives presented. In vitro testing using animal skins and in vivo testing with field workers are being conducted to further assess the efficiency and identify related determinants.
Improvement of Vivarium Biodecontamination through Data-acquisition Systems and Automation.
Devan, Shakthi Rk; Vasu, Suresh; Mallikarjuna, Yogesha; Ponraj, Ramkumar; Kamath, Gireesh; Poosala, Suresh
2018-03-01
Biodecontamination is important for eliminating pathogens at research animal facilities, thereby preventing contamination within barrier systems. We enhanced our facility's standard biodecontamination method to replace the traditional foggers, and the new system was used effectively after creating bypass ducts in HVAC units so that individual rooms could be isolated. The entire system was controlled by inhouse-developed supervisory control and data-acquisition software that supported multiple cycles of decontamination by equipment, which had different decontamination capacities, operated in parallel, and used different agents, including H2O2 vapor and ClO2 gas. The process was validated according to facility mapping, and effectiveness was assessed by using biologic (Geobacillus stearothermophilus) and chemical indicator strips, which were positioned before decontamination, and by sampling contact plates after the completion of each cycle. The results of biologic indicators showed 6-log reduction in microbial counts after successful decontamination cycles for both agents and found to be compatible with clean-room panels including commonly used materials in vivarium such as racks, cages, trolleys, cage changing stations, biosafety cabinets, refrigerators and other equipment in both procedure and animal rooms. In conclusion, the automated process enabled users to perform effective decontamination through multiple cycles with realtime documentation and provided additional capability to deal with potential outbreaks. Enabling software integration of automation improved quality-control systems in our vivarium.
Understanding Contamination; Twenty Years of Simulating Radiological Contamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Emily Snyder; John Drake; Ryan James
A wide variety of simulated contamination methods have been developed by researchers to reproducibly test radiological decontamination methods. Some twenty years ago a method of non-radioactive contamination simulation was proposed at the Idaho National Laboratory (INL) that mimicked the character of radioactive cesium and zirconium contamination on stainless steel. It involved baking the contamination into the surface of the stainless steel in order to 'fix' it into a tenacious, tightly bound oxide layer. This type of contamination was particularly applicable to nuclear processing facilities (and nuclear reactors) where oxide growth and exchange of radioactive materials within the oxide layer becamemore » the predominant model for material/contaminant interaction. Additional simulation methods and their empirically derived basis (from a nuclear fuel reprocessing facility) are discussed. In the last ten years the INL, working with the Defense Advanced Research Projects Agency (DARPA) and the National Homeland Security Research Center (NHSRC), has continued to develop contamination simulation methodologies. The most notable of these newer methodologies was developed to compare the efficacy of different decontamination technologies against radiological dispersal device (RDD, 'dirty bomb') type of contamination. There are many different scenarios for how RDD contamination may be spread, but the most commonly used one at the INL involves the dispersal of an aqueous solution containing radioactive Cs-137. This method was chosen during the DARPA projects and has continued through the NHSRC series of decontamination trials and also gives a tenacious 'fixed' contamination. Much has been learned about the interaction of cesium contamination with building materials, particularly concrete, throughout these tests. The effects of porosity, cation-exchange capacity of the material and the amount of dirt and debris on the surface are very important factors. The interaction of the contaminant/substrate with the particular decontamination technology is also very important. Results of decontamination testing from hundreds of contaminated coupons have lead to certain conclusions about the contamination and the type of decontamination methods being deployed. A recent addition to the DARPA initiated methodology simulates the deposition of nuclear fallout. This contamination differs from previous tests in that it has been developed and validated purely to simulate a 'loose' type of contamination. This may represent the first time that a radiologically contaminated 'fallout' stimulant has been developed to reproducibly test decontamination methods. While no contaminant/methodology may serve as a complete example of all aspects that could be seen in the field, the study of this family of simulation methods provides insight into the nature of radiological contamination.« less
Dwell time considerations for large area cold plasma decontamination
NASA Astrophysics Data System (ADS)
Konesky, Gregory
2009-05-01
Atmospheric discharge cold plasmas have been shown to be effective in the reduction of pathogenic bacteria and spores and in the decontamination of simulated chemical warfare agents, without the generation of toxic or harmful by-products. Cold plasmas may also be useful in assisting cleanup of radiological "dirty bombs." For practical applications in realistic scenarios, the plasma applicator must have both a large area of coverage, and a reasonably short dwell time. However, the literature contains a wide range of reported dwell times, from a few seconds to several minutes, needed to achieve a given level of reduction. This is largely due to different experimental conditions, and especially, different methods of generating the decontaminating plasma. We consider these different approaches and attempt to draw equivalencies among them, and use this to develop requirements for a practical, field-deployable plasma decontamination system. A plasma applicator with 12 square inches area and integral high voltage, high frequency generator is described.
Health investigations of depleted-uranium clean-up workers.
Milacic, Snezana
2008-01-01
The soil contaminated by depleted uranium (238U) ammunition during the NATO bombing of Serbia and Montenegro was cleaned-up for four months in 2002. A team of 11 clean-up workers (expert members) were medically examined three times: before decontamination as a preliminary medical check-up, immediately after decontamination, and four years after cleaning up contaminated ground. This short report presents investigations and health risk assessments of clean-up workers in radioactive decontamination operations and an assessment of the environmental health perspectives for citizens living in surrounding areas. The method of initial health disorders was used, analyzing the most sensitive biological materials, such as blood cells or chromosome damage, DNA strand breaks, radio-toxicological examination of urine. The total number of blood cells did not change, but variations of the relative number (percentage) of cells in the leukocyte formula were observed. The total number of DNA alterations was higher immediately after decontamination than before decontamination. Four years after decontamination the number of DNA alterations had decreased. However, the number of damaged cells (lymphocytes containing chromosome lesions) was higher in both medical examinations, immediately after and four years after decontamination. Disease or tumours due to 238U did not develop in the group of depleted uranium clean-up workers during the investigation period of four years. Further monitoring of haematological and chromosomal effects and the health condition of workers is necessary.
Oxidative decontamination of chemical and biological warfare agents using L-Gel.
Raber, Ellen; McGuire, Raymond
2002-08-05
A decontamination method has been developed using a single reagent that is effective both against chemical warfare (CW) and biological warfare (BW) agents. The new reagent, "L-Gel", consists of an aqueous solution of a mild commercial oxidizer, Oxone, together with a commercial fumed silica gelling agent, Cab-O-Sil EH-5. L-Gel is non-toxic, environmentally friendly, relatively non-corrosive, maximizes contact time because of its thixotropic nature, clings to walls and ceilings, and does not harm carpets or painted surfaces. The new reagent also addresses the most demanding requirements for decontamination in the civilian sector, including availability, low maintenance, ease of application and deployment by a variety of dispersal mechanisms, minimal training and acceptable expense. Experiments to test the effectiveness of L-Gel were conducted at Lawrence Livermore National Laboratory and independently at four other locations. L-Gel was tested against all classes of chemical warfare agents and against various biological warfare agent surrogates, including spore-forming bacteria and non-virulent strains of real biological agents. Testing showed that L-Gel is as effective against chemical agents and biological materials, including spores, as the best military decontaminants.
Large-Area Chemical and Biological Decontamination Using a High Energy Arc Lamp (HEAL) System.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Duty, Chad E; Smith, Rob R; Vass, Arpad Alexander
2008-01-01
Methods for quickly decontaminating large areas exposed to chemical and biological (CB) warfare agents can present significant logistical, manpower, and waste management challenges. Oak Ridge National Laboratory (ORNL) is pursuing an alternate method to decompose CB agents without the use of toxic chemicals or other potentially harmful substances. This process uses a high energy arc lamp (HEAL) system to photochemically decompose CB agents over large areas (12 m2). Preliminary tests indicate that more than 5 decades (99.999%) of an Anthrax spore simulant (Bacillus globigii) were killed in less than 7 seconds of exposure to the HEAL system. When combined withmore » a catalyst material (TiO2) the HEAL system was also effective against a chemical agent simulant, diisopropyl methyl phosphonate (DIMP). These results demonstrate the feasibility of a rapid, large-area chemical and biological decontamination method that does not require toxic or corrosive reagents or generate hazardous wastes.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joiner, R.L.; Harroff, H.H.; Snider, H.
1987-12-04
A rabbit model has been developed and validated for screening noninvasive candidate decontamination systems for their efficacies against topical exposure to the organophosphage chemical surety materiel (CSM), GD, polymer-thickened GD (TGD), and VX. CSM was applied to rabbits in groups of 8 on their clipped dorsa over a range of doses. Dose sites were decontaminated beginning 2 minutes after exposure with both components of the M258A1 standard field kit in the recommended sequence. Replicate LD50s were calculated for each CSM with probit analyses of the doses and lethality rates from replicate studies. A composite LD50 was calculated from the datamore » pooled across replicates for each CSM. The composite LD50 was validated for each CSM by comparing the lethality rate obtained in three replicates of 8 animals each with the population mean of 50 percent. The LD50 values obtained for the three CSM tested produced valid mortality ratios when compared to the population mean. Thus the screen is ready to test candidate decontamination systems. The screen compares the lethality rate obtained from 8 animals each dosed at the established M258A1 LD50 and decontaminated according to the manufacturer's instructions with a candidate system against the population mean of 50 percent. An M258A1-decontaminated control group of 8 animals is included to check for drift via a control chart method. Any candidate decontamination system that is as effective as or more effective than the dual-component M258A1 standard passes the screen and is a candidate for further testing.« less
André, Carolina Bosso; Dos Santos, Andressa; Pfeifer, Carmem Silvia; Giannini, Marcelo; Girotto, Emerson Marcelo; Ferracane, Jack Liborio
2018-04-01
This study evaluated three different sterilization/disinfection techniques for resin composites on bacterial growth and surface modification after decontamination. Two resin composites were sterilized/disinfected with three different techniques: UV light, 1% chloramine T, and 70% ethanol. Four different times were used for each technique to determine the shortest time that the solution or UV light was effective. The influence of sterilization/disinfection technique on bacterial growth was evaluated by analyzing the metabolic activity, using the AlamarBlue™ assay, bacterial viability, and SEM images from biofilms of Streptococcus mutans. The surface change, after the process, was analyzed with ATR/FTIR and SEM images. The solutions used for decontamination (1% chloramine-T and 70% ethanol) were analyzed with 1 H-NMR to identify any resin compounds leached during the process. One minute of decontamination was efficient for all three methods tested. Chloramine-T increased the surface porosity on resin composites, no changes were observed for UV light and 70% ethanol, however, 1 H-NMR identified leached monomers only when 70% ethanol was used. No chemical change of the materials was found under ATR/FTIR analyses after the decontamination process. Chloramine-T, with no previous wash, increased the bacterial viability for both resin composites and increased the bacterial metabolism for the resin composite without fluoride. UV light had no interference on the resin composites properties tested using 1 min of exposure compared to the other decontamination methods. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 945-953, 2018. © 2017 Wiley Periodicals, Inc.
Transfer of radio-cesium from forest soil to woodchips using fungal activities
NASA Astrophysics Data System (ADS)
Kaneko, Nobuhiro; Huang, Yao; Tanaka, Yoichiro; Fujiwara, Yoshihiro; Sasaki, Michiko; Toda, Hiroto; Takahashi, Terumasa; Kobayashi, Tatsuaki; Harada, Naoki; Nonaka, Masahiro
2014-05-01
Raido-cesium released to terrestrial ecosystems by nuclear accidents is know to accumulate forest soil and organic layer on the soil. Forests in Japan are not exceptions. Practically it is impossible to decontaminate large area of forests. However, there is a strong demand from local people, who has been using secondary forests (Satoyama) around croplands in hilly areas, to decontaminate radio-cesium, because those people used to collect wild mushrooms and edible plants, and there are active cultures of mushrooms using logs and sawdusts. These natural resource uses consist substantial part of their economical activities, Therefore it is needed to decontaminate some selected part of forests in Japan to local economy. Clear cutting and scraping surface soil and organic matter are common methods of decontamination. However the efficiency of decontamination is up to 30% reduction of aerial radiation, and the cost to preserve contaminated debris is not affordable. In this study we used wood chips as a growth media for saprotrophic fungi which are known to accumulate redio-cesium. There are many studies indicated that mushrooms accumulated redio-cesium from forest soil and organic layer. It is not practical to collect mushrooms to decontaminate redio-cesium, because biomass of mushrooms are not enough to collect total contaminants. Mushrooms are only minor part of saprotrophic fungi. Fungal biomass in forest soil is about 1% of dead organic matter on forest floor. Our previous study to observe Cs accumulation to decomposing leaf litter indicated 18% absorption of total soil radio-Cs to litter during one year field incubation (Kaneko et al., 2013), and Cs concentration was proportional to fungal biomass on litter. This result indicated that fungi transferred radio-cesium around newly supplied leaf litter free of contamination. Therefore effective decontamination will be possible if we can provide large amount of growth media for saprotrophic fungi, and the media can be removed from forests with fungal bodies. We covered forest floor using wood chips, and observed Cs accumulation, and found that up to 50% of soil radio-cesium was transferred from soil to wood chips after 6-month of field incubation. Therefore this method is effective to decontaminate forest using ecological process. Kaneko N, Huang Y, Nakamori T, Tanaka Y, Nonaka M. Radio-cesium accumulation during decomposition of leaf litter in a deciduous forest after the Fukushima NPP accident. Geophysical Research Abstracts. 2013;15(EGU2013):7809.
Chilcott, Robert P; Mitchell, Hannah; Matar, Hazem
2018-05-30
The UK's Initial Operational Response (IOR) is a new process for improving the survival of multiple casualties following a chemical, biological, radiological or nuclear incident. Whilst the introduction of IOR represents a patient-focused response for ambulant casualties, there is currently no provision for disrobe and dry decontamination of nonambulant casualties. Moreover, the current specialist operational response (SOR) protocol for nonambulant casualty decontamination (also referred to as "clinical decontamination") has not been subject to rigorous evaluation or development. Therefore, the aim of this study was to confirm the effectiveness of putatively optimized dry (IOR) and wet (SOR) protocols for nonambulant decontamination in human volunteers. Dry and wet decontamination protocols were objectively evaluated using human volunteers. Decontamination effectiveness was quantified by liquid chromatography-mass spectrometry analysis of the recovery of a chemical warfare agent simulant (methylsalicylate) from skin and hair of volunteers, with whole-body fluorescence imaging to quantify the skin distribution of residual simulant. Both the dry and wet decontamination processes were rapid (3 and 4 min, respectively) and were effective in removing simulant from the hair and skin of volunteers, with no observable adverse effects related to skin surface spreading of contaminant. Further studies are required to assess the combined effectiveness of dry and wet decontamination under more realistic conditions and to develop appropriate operational procedures that ensure the safety of first responders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wille, H.; Bertholdt, H.O.; Operschall, H.
Efforts to reduce occupational radiation exposure during inspection and repair work in nuclear power plants turns steadily increasing attention to the decontamination of systems and components. Due to the advanced age of nuclear power plants resulting in increasing dose rates, the decontamination of components, or rather of complete systems, or loops to protect operating and inspection personnel becomes demanding. Besides, decontaminating complete primary loops is in many cases less difficult than cleaning large components. Based on experience gained in nuclear power plants, an outline of two different decontamination methods performed recently are given. For the decontamination of complete systems ormore » loops, Kraftwerk Union AG has developed CORD, a low-concentration process. For the decontamination performance of a subsystem, such as the steam generator (SG) channel heads of a pressurized water reactor or the recirculation loops of a boiling water reactor the automated mobile decontamination appliance is used. The electrochemical decontamination process is primarily applicable for the treatment of specially limited surface areas.« less
Paolin, Adolfo; Trojan, Diletta; Carniato, Antonio; Tasca, Fabio; Massarin, Ervino; Tugnoli, Alessandro; Cogliati, Elisa
2016-12-01
Bacterial contamination of tissues retrieved from cadaveric donors is a common feature worldwide, and every tissue bank, albeit using different methods, conducts decontamination to guarantee safe tissues suitable for clinical use. The effectiveness of the methods used to eradicate pathogens differs. In order to reduce the tissue bioburden at retrieval, we have introduced a new method involving rinsing tissues in a sodium hypochlorite solution. To test its effectiveness we analyzed two comparable groups of tissues: Group A: 1881 tissues, all rinsed with isotonic saline solution after retrieval, and Group B: 1968 tissues immersed in an isotonic saline solution containing sodium hypochlorite (final concentration 0.1 %) for different lengths of time and subsequently rinsed with isotonic saline. The rinsing solution of each tissue was then sampled for microbiological cultures in both groups. The resultant overall contamination rate was 40.5 % for Group A and 6.7 % for Group B, with an 82.8 % difference in the reduction of contamination between the two groups. This was especially the case for commensal skin bacteria in musculoskeletal tissue, which accounted for over half the overall contamination. Our data highlighted that decontamination with sodium hypochlorite was helpful in reducing the bacterial bioburden in tissues retrieved from cadaveric donors.
NATIONAL RESPONSE TEAM TECHNICAL ASSISTANCE ...
This document provides technical information on a wide range of activities to aid in response to intentional release of anthrax in urban environments. It includes initial actions when a potential release is discovered, health and safety issues for responders, sampling and analysis methods, decontamination technologies, decontamination waste disposal, and communication with public. This document provides technical information on a wide range of activities to aid in response to intentional release of anthrax in urban environments. It includes initial actions when a potential release is discovered, health and safety issues for responders, sampling and analysis methods, decontamination technologies, decontamination waste disposal, and communication with public.
Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte‐Davidson, Raquel
2017-01-01
Abstract Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining non‐toxic at the dose applied. This review focuses on studies that employed chemical warfare agent simulants in decontamination contexts, to identify those simulants most suitable for use in HVTs of emergency decontamination. Twenty‐two simulants were identified, of which 17 were determined unsuitable for use in HVTs. The remaining simulants (n = 5) were further scrutinized for potential suitability according to toxicity, physicochemical properties and similarities to their equivalent toxic counterparts. Three suitable simulants, for use in HVTs were identified; methyl salicylate (simulant for sulphur mustard), diethyl malonate (simulant for soman) and malathion (simulant for VX or toxic industrial chemicals). All have been safely used in previous HVTs, and have a range of physicochemical properties that would allow useful inference to more toxic chemicals when employed in future studies of emergency decontamination systems. PMID:28990191
Arsenic removal by electrocoagulation process: Recent trends and removal mechanism.
Nidheesh, P V; Singh, T S Anantha
2017-08-01
Arsenic contamination in drinking water is a major issue in the present world. Arsenicosis is the disease caused by the regular consumption of arsenic contaminated water, even at a lesser contaminated level. The number of arsenicosis patients is increasing day-by-day. Decontamination of arsenic from the water medium is the only one way to regulate this and the arsenic removal can be fulfilled by water treatment methods based on separation techniques. Electrocoagulation (EC) process is a promising technology for the effective removal of arsenic from aqueous solution. The present review article analyzes the performance of the EC process for arsenic removal. Electrocoagulation using various sacrificial metal anodes such as aluminium, iron, magnesium, etc. is found to be very effective for arsenic decontamination. The performances of each anode are described in detail. A special focus has been made on the mechanism behind the arsenite and arsenate removal by EC process. Main trends in the disposal methods of sludge containing arsenic are also included. Comparison of arsenic decontamination efficiencies of chemical coagulation and EC is also reported. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Huang, Zhengkai; Wang, Haihong; Luo, Zhicai
2017-04-01
Due to the complex coastal topography and energetic ocean dynamics effect, the return echoes are contaminated while the satellite footprint approaches or leaves the coastline. Specular peaks are often induced in the trailing edges of contaminated waveforms, thus leading the error in the determination of the leading edge and associated track offset in the waveform retracking process. We propose an improved algorithm base on Tseng's modification method to decontaminated coastal (0-7 km from coastline) waveforms, thus improving both the utilization and precision of coastal sea surface height (SSH). Using the Envisat/Jason-2 SGDR data, the shortcoming of Tseng's method is pointed out and the novel algorithm is proposed by revising the strategy of selecting reference waveform and determining weight for removing outlier. The reference waveform of the decontaminated technology is closer to the real waveform of the offshore area, which avoids the over-modification problem of Tseng method. The sea-level measurements from tide gauge station and geoid height from EGM2008 model were used to validate the retracking strategy. Experimental results show that decontaminated waveform was more suitable than original and Tseng modified waveform and has uniform performance in both compare to the tide gauge and geoid. The retrieved altimetry data in the 0-1km and 1-7km coastal zone indicate that threshold retracker with decontaminated waveform have STD of 73.8cm and 33cm as compared with in situ gauge data,which correspond to 62.1% and 58% in precession compared to the unretracked altimetry measurements. The retracked SSHs are better in two coastal (0-1 km and 1-7km) zones, which have STD of 11.9cm and 22.7cm as compared with geoid height. Furthermore, the comparisons shows that the precision of decontaminated technology improve 0.3cm and 3.3cm than the best result of PISTACH product in coastal sea. This work is supported by the National Natural Science Foundation of China (Grant Nos. 41174020, 41174021, 41131067) and the open fund of Guangxi Key Laboratory of Spatial Information and Geometrics (Grant No. 15-140-07-26). Index Terms: retracking, Envisat, Jason-2, Coastal sea, decontamination.
A biological decontamination process for small, privately owned buildings.
Krauter, Paula; Tucker, Mark
2011-09-01
An urban wide-area recovery and restoration effort following a large-scale biological release will require extensive resources and tax the capabilities of government authorities. Further, the number of private decontamination contractors available may not be sufficient to respond to the needs. These resource limitations could create the need for decontamination by the building owner/occupant. This article provides owners/occupants with a simple method to decontaminate a building or area following a wide-area release of Bacillus anthracis using liquid sporicidal decontamination materials, such as pH-amended bleach or activated peroxide; simple application devices; and high-efficiency particulate air-filtered vacuums. Owner/occupant decontamination would be recommended only after those charged with overseeing decontamination-the Unified Command/Incident Command-identify buildings and areas appropriate for owner/occupant decontamination based on modeling and environmental sampling and conduct health and safety training for cleanup workers.
Decontamination training: with and without virtual reality simulation.
Farra, Sharon Lee; Smith, Sherrill; Gillespie, Gordon Lee; Nicely, Stephanie; Ulrich, Deborah L; Hodgson, Eric; French, DeAnne
2015-01-01
Nurses must be prepared to care for patients following a disaster, including patients exposed to hazardous contaminants. The purpose of this study was to examine the use of virtual reality simulation (VRS) to teach the disaster-specific skill of decontamination. A quasi-experimental design was used to assign nursing students from 2 baccalaureate nursing programs to 1 of 2 groups to learn the disaster skill of decontamination-printed written directions or VRS. Performance, knowledge, and self-efficacy were outcome measures. Although students in the treatment group had significantly lower performance scores than the control group (p = 0.004), students taking part in VRS completed the skill in a significantly shorter amount of time (p = 0.008). No significant group differences were found for self-efficacy (p = 0.172) or knowledge (p = 0.631). However, students in the VRS treatment group reported high levels of satisfaction with VRS as a training method. The disaster-specific skill of decontamination is a low-volume, high-risk skill that must be performed with accuracy to protect both exposed patients and providers performing decontamination. As frontline providers for casualties following a disaster event, emergency nurses must be prepared to perform this skill when needed. Preparation requires cost-effective, timely, and evidence-based educational opportunities that promote positive outcomes. Further investigation is needed to determine the benefits and long-term effects of VRS for disaster education.
Method and apparatus for the gas phase decontamination of chemical and biological agents
O'Neill, Hugh J.; Brubaker, Kenneth L.
2003-10-07
An apparatus and method for decontaminating chemical and biological agents using the reactive properties of both the single atomic oxygen and the hydroxyl radical for the decontamination of chemical and biological agents. The apparatus is self contained and portable and allows for the application of gas reactants directly at the required decontamination point. The system provides for the use of ultraviolet light of a specific spectral range to photolytically break down ozone into molecular oxygen and hydroxyl radicals where some of the molecular oxygen is in the first excited state. The excited molecular oxygen will combine with water vapor to produce two hydroxyl radicals.
Decontamination of Anthrax spores in critical infrastructure and critical assets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Boucher, Raymond M.; Crown, Kevin K.; Tucker, Mark David
2010-05-01
Decontamination of anthrax spores in critical infrastructure (e.g., subway systems, major airports) and critical assets (e.g., the interior of aircraft) can be challenging because effective decontaminants can damage materials. Current decontamination methods require the use of highly toxic and/or highly corrosive chemical solutions because bacterial spores are very difficult to kill. Bacterial spores such as Bacillus anthracis, the infectious agent of anthrax, are one of the most resistant forms of life and are several orders of magnitude more difficult to kill than their associated vegetative cells. Remediation of facilities and other spaces (e.g., subways, airports, and the interior of aircraft)more » contaminated with anthrax spores currently requires highly toxic and corrosive chemicals such as chlorine dioxide gas, vapor- phase hydrogen peroxide, or high-strength bleach, typically requiring complex deployment methods. We have developed a non-toxic, non-corrosive decontamination method to kill highly resistant bacterial spores in critical infrastructure and critical assets. A chemical solution that triggers the germination process in bacterial spores and causes those spores to rapidly and completely change to much less-resistant vegetative cells that can be easily killed. Vegetative cells are then exposed to mild chemicals (e.g., low concentrations of hydrogen peroxide, quaternary ammonium compounds, alcohols, aldehydes, etc.) or natural elements (e.g., heat, humidity, ultraviolet light, etc.) for complete and rapid kill. Our process employs a novel germination solution consisting of low-cost, non-toxic and non-corrosive chemicals. We are testing both direct surface application and aerosol delivery of the solutions. A key Homeland Security need is to develop the capability to rapidly recover from an attack utilizing biological warfare agents. This project will provide the capability to rapidly and safely decontaminate critical facilities and assets to return them to normal operations as quickly as possible, sparing significant economic damage by re-opening critical facilities more rapidly and safely. Facilities and assets contaminated with Bacillus anthracis (i.e., anthrax) spores can be decontaminated with mild chemicals as compared to the harsh chemicals currently needed. Both the 'germination' solution and the 'kill' solution are constructed of 'off-the-shelf,' inexpensive chemicals. The method can be utilized by directly spraying the solutions onto exposed surfaces or by application of the solutions as aerosols (i.e., small droplets), which can also reach hidden surfaces.« less
Gitteh, Ensa; Kweku Otu, Jacob; Jobarteh, Tijan; Mendy, Francis; Faal-Jawara, Isatou Tutty; Ofori-Anyinam, Nana Boatema; Ayorinde, Abigail; Secka, Ousman; Gehre, Florian
2016-12-01
To determine the culture yield and time to detection of mycobacterial growth between samples decontaminated using 0.7% chlorhexidine and sodium hydroxide-N-acetyl-l-cysteine (NaOH-NALC) and cultured on the Löwenstein-Jensen (LJ) medium. We also aimed to determine the contamination rate between the 0.7% chlorhexidine and NaOH-NALC decontamination methods. The study was carried out on 68 sputa samples (42 smear positives and 26 smear negatives). Of these 68 samples, 46 were collected from men and 26 from women with an approximate average age of 27years. All the sputum samples were decontaminated using the standard NaOH-NALC and 0.7% chlorhexidine methods. The concentrates were cultured in parallel on LJ media in which reading of the slope for mycobacterial growth was obtained daily for the first 2weeks and then weekly until week 8. The mycobacterial recovery rate, time to detection, and contamination rate were then compared. The overall recovery rate of mycobacterial growth on samples treated with both decontamination methods inoculated on LJ media is 51.5% (35/68). Specifically, mycobacterial growth rates on samples treated with 0.7% chlorhexidine and standard NaOH-NALC on LJ media were 61.8% (42/68) and 54.4% (37/68), respectively. However, the growth of Mycobacterium tuberculosis complex was faster on samples treated with 0.7% chlorhexidine than those treated with NaOH-NALC (average, 32±5days vs. 33±5.2days, respectively). The contamination rate on samples treated with 0.7% chlorhexidine was 1.5% (1/68), whereas on those treated with NaOH-NALC, the rate was 4.4% (3/68). The 0.7% chlorhexidine decontamination method is rapid and has less contamination rate in terms of mycobacterial recovery compared with the standard NaOH-NALC method. Therefore, the 0.7% chlorhexidine decontamination method would be an ideal alternative option for decontamination of sputum samples and recovery/isolation of M. tuberculosis in resource-poor countries. Copyright © 2016.
Gross decontamination experiment report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mason, R.; Kinney, K.; Dettorre, J.
1983-07-01
A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established formore » the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.« less
Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G James; Williams, Richard
2014-01-01
The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) 'Theory-based communication': Health-focused explanations about decontamination, and sufficient practical information; 2) 'Standard practice communication': No health-focused explanations about decontamination, sufficient practical information; 3) 'Brief communication': No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased identification with responders, which in turn resulted in higher levels of expected compliance during a real incident, and increased willingness to help other members of the public. This study shows that an understanding of the social identity approach facilitates the development of effective responder communication strategies for incidents involving mass decontamination.
Carter, Holly; Drury, John; Amlôt, Richard; Rubin, G. James; Williams, Richard
2014-01-01
The risk of incidents involving mass decontamination in response to a chemical, biological, radiological, or nuclear release has increased in recent years, due to technological advances, and the willingness of terrorists to use unconventional weapons. Planning for such incidents has focused on the technical issues involved, rather than on psychosocial concerns. This paper presents a novel experimental study, examining the effect of three different responder communication strategies on public experiences and behaviour during a mass decontamination field experiment. Specifically, the research examined the impact of social identity processes on the relationship between effective responder communication, and relevant outcome variables (e.g. public compliance, public anxiety, and co-operative public behaviour). All participants (n = 111) were asked to visualise that they had been involved in an incident involving mass decontamination, before undergoing the decontamination process, and receiving one of three different communication strategies: 1) ‘Theory-based communication’: Health-focused explanations about decontamination, and sufficient practical information; 2) ‘Standard practice communication’: No health-focused explanations about decontamination, sufficient practical information; 3) ‘Brief communication’: No health-focused explanations about decontamination, insufficient practical information. Four types of data were collected: timings of the decontamination process; observational data; and quantitative and qualitative self-report data. The communication strategy which resulted in the most efficient progression of participants through the decontamination process, as well as the fewest observations of non-compliance and confusion, was that which included both health-focused explanations about decontamination and sufficient practical information. Further, this strategy resulted in increased perceptions of responder legitimacy and increased identification with responders, which in turn resulted in higher levels of expected compliance during a real incident, and increased willingness to help other members of the public. This study shows that an understanding of the social identity approach facilitates the development of effective responder communication strategies for incidents involving mass decontamination. PMID:24595097
Hens, Bart; Hens, Luc
2017-12-21
Polychlorinated biphenyl (PCB)-contaminated sites around the world affect human health for many years, showing long latency periods of health effects. The impact of the different PCB congeners on human health should not be underestimated, as they are ubiquitous, stable molecules and reactive in biological tissues, leading to neurological, endocrine, genetic, and systemic adverse effects in the human body. Moreover, bioaccumulation of these compounds in fatty tissues of animals (e.g., fish and mammals) and in soils/sediments, results in chronic exposure to these substances. Efficient destruction methods are important to decontaminate polluted sites worldwide. This paper provides an in-depth overview of (i) the history and accidents with PCBs in the 20th century, (ii) the mechanisms that are responsible for the hazardous effects of PCBs, and (iii) the current policy regarding PCB control and decontamination. Contemporary impacts on human health of historical incidents are discussed next to an up to date overview of the health effects caused by PCBs and their mechanisms. Methods to decontaminate sites are reviewed. Steps which lead to a policy of banning the production and distribution of PCBs are overviewed in a context of preventing future accidents and harm to the environment and human health.
Hens, Luc
2017-01-01
Polychlorinated biphenyl (PCB)-contaminated sites around the world affect human health for many years, showing long latency periods of health effects. The impact of the different PCB congeners on human health should not be underestimated, as they are ubiquitous, stable molecules and reactive in biological tissues, leading to neurological, endocrine, genetic, and systemic adverse effects in the human body. Moreover, bioaccumulation of these compounds in fatty tissues of animals (e.g., fish and mammals) and in soils/sediments, results in chronic exposure to these substances. Efficient destruction methods are important to decontaminate polluted sites worldwide. This paper provides an in-depth overview of (i) the history and accidents with PCBs in the 20th century, (ii) the mechanisms that are responsible for the hazardous effects of PCBs, and (iii) the current policy regarding PCB control and decontamination. Contemporary impacts on human health of historical incidents are discussed next to an up to date overview of the health effects caused by PCBs and their mechanisms. Methods to decontaminate sites are reviewed. Steps which lead to a policy of banning the production and distribution of PCBs are overviewed in a context of preventing future accidents and harm to the environment and human health. PMID:29267240
Malek, Ammar; Hachemi, Messaoud; Didier, Villemin
2009-10-15
Herein, we describe an original novel method which allows the decontamination of the chromium-containing leather wastes to simplify the recovery of its considerable protein fractions. Organic salts and acids such as potassium oxalate, potassium tartrate, acetic and citric acids were tested for their efficiency to separate the chromium from the leather waste. Our investigation is based on the research of the total reversibility of the tanning process, in order to decontaminate the waste without its previous degradation or digestion. The effect of several influential parameters on the treatment process was also studied. Therefore, the action of chemical agents used in decontamination process seems very interesting. The optimal yield of chromium extraction about 95% is obtained. The aim of the present study is to define a preliminary processing of solid leather waste with two main impacts: Removing with reusing chromium in the tanning process with simple, ecological and economic treatment process and potential valorization of the organic matrix of waste decontaminated.
Decontamination of Drinking Water Infrastructure ...
Technical Brief This study examines the effectiveness of decontaminating corroded iron and cement-mortar coupons that have been contaminated with spores of Bacillus atrophaeus subsp. globigii (B. globigii), which is often used as a surrogate for pathogenic B. anthracis (anthrax) in disinfection studies. Bacillus spores are persistent on common drinking water material surfaces like corroded iron, requiring physical or chemical methods to decontaminate the infrastructure. In the United States, free chlorine and monochloramine are the primary chemical disinfectants used by the drinking water industry to inactivate microorganisms. Flushing is also a common, easily implemented practice in drinking water distribution systems, although large volumes of contaminated water needing treatment could be generated. Identifying readily available alternative disinfectant formulations for infrastructure decontamination could give water utilities options for responding to specific types of contamination events. In addition to presenting data on flushing alone, which demonstrated the persistence of spores on water infrastructure in the absence of high levels of disinfectants, data on acidified nitrite, chlorine dioxide, free chlorine, monochloramine, ozone, peracetic acid, and followed by flushing are provided.
Stjärne Aspelund, A; Sjöström, K; Olsson Liljequist, B; Mörgelin, M; Melander, E; Påhlman, L I
2016-09-01
Pseudomonas aeruginosa may colonize water systems via biofilm formation. In hospital environments, contaminated sinks have been associated with nosocomial transmission. Here we describe a prolonged outbreak of a metallo-β-lactamase-producing P. aeruginosa (Pae-MBL) associated with sink drains, and propose a previously unreported decontamination method with acetic acid. To describe a nosocomial outbreak of Pae-MBL associated with hospital sink drains and to evaluate acetic acid as a decontamination method. The outbreak was investigated by searching the microbiology database, microbiological sampling and strain typing. Antibacterial and antibiofilm properties of acetic acid were evaluated in vitro. Pae-MBL-positive sinks were treated with 24% acetic acid once weekly and monitored with repeated cultures. Fourteen patients with positive cultures for Pae-MBL were identified from 2008 to 2014. The patients had been admitted to three wards, where screening discovered Pae-MBL in 12 sink drains located in the patient bathrooms. Typing of clinical and sink drain isolates revealed identical or closely related strains. Pae-MBL biofilm was highly sensitive to acetic acid with a minimum biofilm eradication concentration of 0.75% (range: 0.19-1.5). Weekly treatment of colonized sink drains with acetic acid resulted in negative cultures and terminated transmission. Acetic acid is highly effective against Pae-MBL biofilms, and may be used as a simple method to decontaminate sink drains and to prevent nosocomial transmission. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
[Decontamination of dental unit waterlines using disinfectants and filters].
Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L
2002-10-01
Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.
Decontamination of VX, GD, and HD on a surface using modified vaporized hydrogen peroxide.
Wagner, George W; Sorrick, David C; Procell, Lawrence R; Brickhouse, Mark D; Mcvey, Iain F; Schwartz, Lewis I
2007-01-30
Vaporized hydrogen peroxide (VHP) has proven efficacy for biological decontamination and is a common gaseous sterilant widely used by industry. Regarding chemical warfare agent decontamination, VHP is also effective against HD and VX, but not GD. Simple addition of ammonia gas to VHP affords reactivity toward GD, while maintaining efficacy for HD (and bioagents) and further enhancing efficacy for VX. Thus, modified VHP is a broad-spectrum CB decontaminant suitable for fumigant-type decontamination scenarios, i.e., building, aircraft, and vehicle interiors and sensitive equipment. Finally, as an interesting aside to the current study, commercial ammonia-containing cleaners are also shown to be effective surface decontaminants for GD, but not for VX or HD.
Misik, Jan; Pavlikova, Ruzena; Josse, Denis; Cabal, Jiri; Kuca, Kamil
2012-09-01
Misuse of various chemicals, such as chemical warfare agents, industrial chemicals or pesticides during warfare or terrorists attacks requires adequate protection. Thus, development and evaluation of novel decontamination dispositives and techniques are needed. In this study, in vitro permeation and decontamination of a potentially hazardous compound paraoxon, an active metabolite of organophosphorus pesticide parathion, was investigated. Skin permeation and decontamination experiments were carried out in modified Franz diffusion cells. Pig skin was used as a human skin model. Commercially produced detergent-based washing solutions FloraFree(™) and ArgosTM were used as decontamination means. The experiments were done under "warm", "cold", "dry" and "wet" skin conditions in order to determine an effect of various physical conditions on skin permeation of paraoxon and on a subsequent decontamination process. There was no significant difference in skin permeation of paraoxon under warm, cold and dry conditions, whereas wet conditions provided significantly higher permeation rates. In the selected conditions, decontamination treatments performed 1 h after a skin exposure did not decrease the agent volume that permeated through the skin. An exception were wet skin conditions with non-significant decontamination efficacy 18 and 28% for the FloraFree(™) and Argos(™) treatment, respectively. In contrast, the skin permeation of paraoxon under warm, cold and dry conditions increased up to 60-290% following decontamination compared to non-decontaminated controls. This has previously been described as a skin wash-in effect.
James, Thomas; Wyke, Stacey; Marczylo, Tim; Collins, Samuel; Gaulton, Tom; Foxall, Kerry; Amlôt, Richard; Duarte-Davidson, Raquel
2018-01-01
Incidents involving the release of chemical agents can pose significant risks to public health. In such an event, emergency decontamination of affected casualties may need to be undertaken to reduce injury and possible loss of life. To ensure these methods are effective, human volunteer trials (HVTs) of decontamination protocols, using simulant contaminants, have been conducted. Simulants must be used to mimic the physicochemical properties of more harmful chemicals, while remaining non-toxic at the dose applied. This review focuses on studies that employed chemical warfare agent simulants in decontamination contexts, to identify those simulants most suitable for use in HVTs of emergency decontamination. Twenty-two simulants were identified, of which 17 were determined unsuitable for use in HVTs. The remaining simulants (n = 5) were further scrutinized for potential suitability according to toxicity, physicochemical properties and similarities to their equivalent toxic counterparts. Three suitable simulants, for use in HVTs were identified; methyl salicylate (simulant for sulphur mustard), diethyl malonate (simulant for soman) and malathion (simulant for VX or toxic industrial chemicals). All have been safely used in previous HVTs, and have a range of physicochemical properties that would allow useful inference to more toxic chemicals when employed in future studies of emergency decontamination systems. © 2017 Crown Copyright. Journal of Applied Toxicology published by John Wiley & Sons, Ltd.
Decontamination of Soil Contaminated with Bacillus anthracis ...
Technical Brief This technical summary will provide decontamination personnel rapid access to information on which decontamination approaches are most effective for soils contaminated with B anthracis.
Lessons Learned from Decontamination Experiences
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorensen, JH
2000-11-16
This interim report describes a DOE project currently underway to establish what is known about decontamination of buildings and people and the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who weremore » decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.« less
Cleaning, disinfection and sterilization of surface prion contamination.
McDonnell, G; Dehen, C; Perrin, A; Thomas, V; Igel-Egalon, A; Burke, P A; Deslys, J P; Comoy, E
2013-12-01
Prion contamination is a risk during device reprocessing, being difficult to remove and inactivate. Little is known of the combined effects of cleaning, disinfection and sterilization during a typical reprocessing cycle in clinical practice. To investigate the combination of cleaning, disinfection and/or sterilization on reducing the risk of surface prion contamination. In vivo test methods were used to study the impact of cleaning alone and cleaning combined with thermal disinfection and high- or low-temperature sterilization processes. A standardized test method, based on contamination of stainless steel wires with high titres of scrapie-infected brain homogenates, was used to determine infectivity reduction. Traditional chemical methods of surface decontamination against prions were confirmed to be effective, but extended steam sterilization was more variable. Steam sterilization alone reduced the risk of prion contamination under normal or extended exposure conditions, but did show significant variation. Thermal disinfection had no impact in these studies. Cleaning with certain defined formulations in combination with steam sterilization can be an effective prion decontamination process, in particular with alkaline formulations. Low-temperature, gaseous hydrogen peroxide sterilization was also confirmed to reduce infectivity in the presence and absence of cleaning. Prion decontamination is affected by the full reprocessing cycle used on contaminated surfaces. The correct use of defined cleaning, disinfection and sterilization methods as tested in this report in the scrapie infectivity assay can provide a standard precaution against prion contamination. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Dalton, Christopher H; Hall, Charlotte A; Lydon, Helen L; Chipman, J K; Graham, John S; Jenner, John; Chilcott, Robert P
2015-05-01
The risk of penetrating, traumatic injury occurring in a chemically contaminated environment cannot be discounted. Should a traumatic injury be contaminated with a chemical warfare (CW) agent, it is likely that standard haemostatic treatment options would be complicated by the need to decontaminate the wound milieu. Thus, there is a need to develop haemostatic products that can simultaneously arrest haemorrhage and decontaminate CW agents. The purpose of this study was to evaluate a number of candidate haemostats for efficacy as skin decontaminants against three CW agents (soman, VX and sulphur mustard) using an in vitro diffusion cell containing undamaged pig skin. One haemostatic product (WoundStat™) was shown to be as effective as the standard military decontaminants Fuller's earth and M291 for the decontamination of all three CW agents. The most effective haemostatic agents were powder-based and use fluid absorption as a mechanism of action to sequester CW agent (akin to the decontaminant Fuller's earth). The envisaged use of haemostatic decontaminants would be to decontaminate from within wounds and from damaged skin. Therefore, WoundStat™ should be subject to further evaluation using an in vitro model of damaged skin. Copyright © 2014 Crown copyright. Journal of Applied Toxicology © 2014 John Wiley & Sons, Ltd.
Sabol, Jonathan P.
2014-01-01
In the event of a wide area release and contamination of a biological agent in an outdoor environment and to building exteriors, decontamination is likely to consume the Nation’s remediation capacity, requiring years to cleanup, and leading to incalculable economic losses. This is in part due to scant body of efficacy data on surface areas larger than those studied in a typical laboratory (5×10-cm), resulting in low confidence for operational considerations in sampling and quantitative measurements of prospective technologies recruited in effective cleanup and restoration response. In addition to well-documented fumigation-based cleanup efforts, agencies responsible for mitigation of contaminated sites are exploring alternative methods for decontamination including combinations of disposal of contaminated items, source reduction by vacuuming, mechanical scrubbing, and low-technology alternatives such as pH-adjusted bleach pressure wash. If proven effective, a pressure wash-based removal of Bacillus anthracis spores from building surfaces with readily available equipment will significantly increase the readiness of Federal agencies to meet the daunting challenge of restoration and cleanup effort following a wide-area biological release. In this inter-agency study, the efficacy of commercial-of-the-shelf sporicidal disinfectants applied using backpack sprayers was evaluated in decontamination of spores on the surfaces of medium-sized (∼1.2 m2) panels of steel, pressure-treated (PT) lumber, and brick veneer. Of the three disinfectants, pH-amended bleach, Peridox, and CASCAD evaluated; CASCAD was found to be the most effective in decontamination of spores from all three panel surface types. PMID:24940605
Haughton, Pippa N; Lyng, James G; Morgan, Desmond J; Cronin, Denis A; Fanning, Seamus; Whyte, Paul
2011-01-01
The efficacy of high-intensity light pulse (HILP) technology (3 Hz, maximum of 505 J/pulse, and a pulse duration of 360 μs) for the decontamination of raw chicken and associated packaging and surface materials was investigated. Its ability to reduce microbial counts on raw chicken through plastic films was also examined. Complete inactivation of Campylobacter spp., Escherichia coli, and Salmonella Enteritidis in liquid was achieved after 30 sec HILP treatment. Reductions of 3.56, 4.69, and 4.60 log₁₀ cfu/cm²) were observed after 5 sec HILP treatment of Campylobacter jejuni, E. coli, and Salmonella Enteritidis inoculated onto packaging materials and contact surfaces, respectively. The greatest reductions on inoculated chicken skin were 1.22, 1.69, and 1.27 log₁₀ cfu/g for C. jejuni, E. coli, and Salmonella Enteritidis, respectively. Corresponding reductions on inoculated skinless breast meat were 0.96, 1.13, and 1.35 log₁₀ cfu/g. The effectiveness of HILP treatment for reducing microbial levels on chicken increased as the film thickness decreased. HILP treatments of 2 sec did not significantly affect the color of raw chicken although treatments of 30 sec impacted color. This study has shown HILP to be an effective method for the decontamination of packaging and surface materials. Additionally, it has demonstrated the potential of HILP to be used as a decontamination method for packaged chicken.
HARAGUSHIKU, Gisele Aihara; BACK, Eduardo Donato Eing Engelke; TOMAZINHO, Paulo Henrique; BARATTO, Flares; FURUSE, Adilson Yoshio
2015-01-01
Objective This study evaluated the effect of root canal disinfectants on the elimination of bacteria from the root canals, as well as their effect on glass-fiber posts bond strength. Material and Methods Fifty-three endodontically treated root canals had post spaces of 11 mm in length prepared and contaminated with E. faecalis. For CFU/ml analysis, eight teeth were contaminated for 1 h or 30 days (n=4). Teeth were decontaminated with 5% NaOCl, 2% CHX, or distilled water. As control, no decontamination was conducted. After decontamination, sterile paper points were used to collect samples, and CFU/ml were counted. For push-out, three groups were evaluated (n=15): irrigation with 2.5% NaOCl, 2% CHX, or sterile distilled water. A bonding agent was applied to root canal dentin, and a glass-fiber post was cemented with a dual-cured cement. After 24 h, 1-mm-thick slices of the middle portion of root canals were obtained and submitted to the push-out evaluation. Three specimens of each group were evaluated in scanning electron microscopy (SEM). Data were analyzed with one-way ANOVA and Dunnett’s T3 test (α=0.05). Results The number of CFU/ml increased from 1 h to 30 days of contamination in control and sterile distilled water groups. Decontamination with NaOCl was effective only when teeth were contaminated for 1 h. CHX was effective at both contamination times. NaOCl did not influence the bond strength (p>0.05). Higher values were observed with CHX (p<0.05). SEM showed formation of resin tags in all groups. Conclusion CHX showed better results for the irrigation of contaminated root canals both in reducing the bacterial contamination and in improving the glass-fiber post bonding. PMID:26398518
Large-Scale Urban Decontamination; Developments, Historical Examples and Lessons Learned
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rick Demmer
2007-02-01
Recent terrorist threats and actual events have lead to a renewed interest in the technical field of large scale, urban environment decontamination. One of the driving forces for this interest is the real potential for the cleanup and removal of radioactive dispersal device (RDD or “dirty bomb”) residues. In response the U. S. Government has spent many millions of dollars investigating RDD contamination and novel decontamination methodologies. Interest in chemical and biological (CB) cleanup has also peaked with the threat of terrorist action like the anthrax attack at the Hart Senate Office Building and with catastrophic natural events such asmore » Hurricane Katrina. The efficiency of cleanup response will be improved with these new developments and a better understanding of the “old reliable” methodologies. Perhaps the most interesting area of investigation for large area decontamination is that of the RDD. While primarily an economic and psychological weapon, the need to cleanup and return valuable or culturally significant resources to the public is nonetheless valid. Several private companies, universities and National Laboratories are currently developing novel RDD cleanup technologies. Because of its longstanding association with radioactive facilities, the U. S. Department of Energy National Laboratories are at the forefront in developing and testing new RDD decontamination methods. However, such cleanup technologies are likely to be fairly task specific; while many different contamination mechanisms, substrate and environmental conditions will make actual application more complicated. Some major efforts have also been made to model potential contamination, to evaluate both old and new decontamination techniques and to assess their readiness for use. Non-radioactive, CB threats each have unique decontamination challenges and recent events have provided some examples. The U. S. Environmental Protection Agency (EPA), as lead agency for these emergency cleanup responses, has a sound approach for decontamination decision-making that has been applied several times. The anthrax contamination at the U. S. Hart Senate Office Building and numerous U. S. Post Office facilities are examples of employing novel technical responses. Decontamination of the Hart Office building required development of a new approach for high level decontamination of biological contamination as well as techniques for evaluating the technology effectiveness. The World Trade Center destruction also demonstrated the need for, and successful implementation of, appropriate cleanup methodologies. There are a number of significant lessons that can be gained from a look at previous large scale cleanup projects. Too often we are quick to apply a costly “package and dispose” method when sound technological cleaning approaches are available. Understanding historical perspectives, advanced planning and constant technology improvement are essential to successful decontamination.« less
Krauter, Paula; Edwards, Donna; Yang, Lynn; Tucker, Mark
2011-09-01
Decontamination and recovery of a facility or outdoor area after a wide-area biological incident involving a highly persistent agent (eg, Bacillus anthracis spores) is a complex process that requires extensive information and significant resources, which are likely to be limited, particularly if multiple facilities or areas are affected. This article proposes a systematic methodology for evaluating information to select the decontamination or alternative treatments that optimize use of resources if decontamination is required for the facility or area. The methodology covers a wide range of approaches, including volumetric and surface decontamination, monitored natural attenuation, and seal and abandon strategies. A proposed trade-off analysis can help decision makers understand the relative appropriateness, efficacy, and labor, skill, and cost requirements of the various decontamination methods for the particular facility or area needing treatment--whether alone or as part of a larger decontamination effort. Because the state of decontamination knowledge and technology continues to evolve rapidly, the methodology presented here is designed to accommodate new strategies and materials and changing information.
Buzzi, Marina; Guarino, Anna; Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives.
Gatto, Claudio; Manara, Sabrina; Dainese, Luca; Polvani, Gianluca; Tóthová, Jana D'Amato
2014-01-01
We investigated the presence of antibiotics in cryopreserved cardiovascular tissues and cryopreservation media, after tissue decontamination with antibiotic cocktails, and the impact of antibiotic residues on standard tissue bank microbiological analyses. Sixteen cardiovascular tissues were decontaminated with bank-prepared cocktails and cryopreserved by two different tissue banks according to their standard operating procedures. Before and after decontamination, samples underwent microbiological analysis by standard tissue bank methods. Cryopreserved samples were tested again with and without the removal of antibiotic residues using a RESEP tube, after thawing. Presence of antibiotics in tissue homogenates and processing liquids was determined by a modified agar diffusion test. All cryopreserved tissue homogenates and cryopreservation media induced important inhibition zones on both Staphylococcus aureus- and Pseudomonas aeruginosa-seeded plates, immediately after thawing and at the end of the sterility test. The RESEP tube treatment markedly reduced or totally eliminated the antimicrobial activity of tested tissues and media. Based on standard tissue bank analysis, 50% of tissues were found positive for bacteria and/or fungi, before decontamination and 2 out of 16 tested samples (13%) still contained microorganisms after decontamination. After thawing, none of the 16 cryopreserved samples resulted positive with direct inoculum method. When the same samples were tested after removal of antibiotic residues, 8 out of 16 (50%) were contaminated. Antibiotic residues present in tissue allografts and processing liquids after decontamination may mask microbial contamination during microbiological analysis performed with standard tissue bank methods, thus resulting in false negatives. PMID:25397402
Enhancing activated-peroxide formulations for porous materials: Test methods and results
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krauter, Paula; Tucker, Mark D.; Tezak, Matthew S.
2012-12-01
During an urban wide-area incident involving the release of a biological warfare agent, the recovery/restoration effort will require extensive resources and will tax the current capabilities of the government and private contractors. In fact, resources may be so limited that decontamination by facility owners/occupants may become necessary and a simple decontamination process and material should be available for this use. One potential process for use by facility owners/occupants would be a liquid sporicidal decontaminant, such as pHamended bleach or activated-peroxide, and simple application devices. While pH-amended bleach is currently the recommended low-tech decontamination solution, a less corrosive and toxic decontaminantmore » is desirable. The objective of this project is to provide an operational assessment of an alternative to chlorine bleach for low-tech decontamination applications activated hydrogen peroxide. This report provides the methods and results for activatedperoxide evaluation experiments. The results suggest that the efficacy of an activated-peroxide decontaminant is similar to pH-amended bleach on many common materials.« less
PYROCHEMICAL DECONTAMINATION METHOD FOR REACTOR FUEL
Buyers, A.G.
1959-06-30
A pyro-chemical method is presented for decontaminating neutron irradiated uranium and separating plutonium therefrom by contact in the molten state with a metal chloride salt. Uranium trichloride and uranium tetrachloride either alone or in admixture with alkaline metal and alkaline eanth metal fluorides under specified temperature and specified phase ratio conditions extract substantially all of the uranium from the irradiated uranium fuel together with certain fission products. The phases are then separated leaving purified uranium metal. The uranium and plutonium in the salt phase can be reduced to forin a highly decontaminated uraniumplutonium alloy. The present method possesses advantages for economically decontaminating irradiated nuclear fuel elements since irradiated fuel may be proccessed immediately after withdrawal from the reactor and the uranium need not be dissolved and later reduced to the metallic form. Accordingly, the uranium may be economically refabricated and reinserted into the reactor.
DECONTAMINATION OF NEUTRON-IRRADIATED REACTOR FUEL
Buyers, A.G.; Rosen, F.D.; Motta, E.E.
1959-12-22
A pyrometallurgical method of decontaminating neutronirradiated reactor fuel is presented. In accordance with the invention, neutron-irradiated reactor fuel may be decontaminated by countercurrently contacting the fuel with a bed of alkali and alkaine fluorides under an inert gas atmosphere and inductively melting the fuel and tracking the resulting descending molten fuel with induction heating as it passes through the bed. By this method, a large, continually fresh surface of salt is exposed to the descending molten fuel which enhances the efficiency of the scrubbing operation.
2003-05-01
I I I I FINAL • Composition B (TNT, RDX and wax), • Tetryl, • Smokeless Powder ( Nitrocellulose /Nitrogylcerin), and • HBX (TNT, RDX, aluminum...operating-cost system. Because of its temporary, on-site configuration, this is an inherently low-cost method to decontaminate range residue. On... methods ) were evaluated and progressively improved during each test run. 022/masterdocument.doc 4-12 I I I I I I I I I I I I I I I I
Chua, Hoe-Chee; Lee, Hoi-Sim; Sng, Mui-Tiang
2006-01-13
Analysing nitrogen mustards and their degradation products in decontamination emulsions posed a significant challenge due to the different phases present in such matrices. Extensive sample preparation may be required to isolate target analytes. Furthermore, numerous reaction products are formed in the decontamination emulsion. A fast and effective qualitative screening procedure was developed for these compounds, using liquid chromatography-mass spectrometry (LC-MS). This eliminated the need for additional sample handling and derivatisation that are required for gas chromatographic-mass spectrometric (GC-MS) analysis. A liquid chromatograph with mixed mode column and isocratic elution gave good chromatography. The feasibility of applying this technique for detecting these compounds in spiked water and decontamination emulsion was demonstrated. Detailed characterisation of the degradation products in these two matrices was carried out. The results demonstrated that N-methyldiethanolamine (MDEA), N-ethyldiethanolamine (EDEA) and triethanolamine (TEA) are not the major degradation products of their respective nitrogen mustards. Degradation profiles of nitrogen mustards in water were also established. In verification analysis, it is important not only to develop methods for the identification of the actual chemical agents; the methods must also encompass degradation products of the chemical agents as well so as to exclude false negatives. This study demonstrated the increasingly pivotal role that LC-MS play in verification analysis.
Atmospheric Pressure Plasma Jet for Chem/Bio Warfare Decontamination
NASA Astrophysics Data System (ADS)
Herrmann, Hans W.; Henins, Ivars; Park, Jaeyoung; Selwyn, Gary S.
1999-11-01
Atmospheric Pressure Plasma Jet (APPJ) technology may provide a much needed method of CBW decontamination which, unlike traditional decon methods, is dry and nondestructive to sensitive equipment and materials. The APPJ discharge uses a high-flow feedgas consisting primarily of an inert carrier gas, such as He, and a small amount of a reactive additive, such as O2, which flows between capacitively-coupled electrodes powered at 13.56 MHz. The plasma generates highly reactive metastable and atomic species of oxygen which are then directed onto a contaminated surface. The reactive effluent of the APPJ has been shown to effectively neutralize VX nerve agent as well as simulants for anthrax and mustard blister agent. Research efforts are now being directed towards reducing He consumption and increasing the allowable stand-off distance. Recent results demonstrate that by replacing the O2 reactive additive with CO2, ozone formation is greatly reduced. This has the result of extending the lifetime of atomic oxygen by an order of magnitude or more. A recirculating APP Decon Chamber which combines heat, vacuum, forced convection and reactivity is currently being developed for enhanced decontamination of sensitive equipment. Several techniques are also being evaluated for use in an APP Decon Jet for decontamination of items which cannot be placed inside a chamber.
Decontamination of Subway Railcar and Related Materials ...
Report In the event of a biological incident in a transportation hub such as a subway system, effective remediation of railcars, subway tunnels and stations will require the use of various decontamination approaches. One potential decontamination tool that could be used in such an event is the fogging of sporicidal liquids. The study described in this report builds on previous fogging decontamination research, but with a focus on decontaminating subway railcars and related materials.
Technical product bulletin: this miscellaneous oil spill control agent comes already mixed and ready for use in cleanups. Through various application methods, it is effective in shoreline and surface treatment, tank cleaning, and equipment decontamination.
A Simple Decontamination Approach Using Hydrogen ...
Journal article To evaluate the use of relatively low levels of hydrogen peroxide vapor (HPV) for the inactivation of Bacillus anthracis spores within an indoor environment. Methods and Results: Laboratory-scale decontamination tests were conducted using bacterial spores of both B. anthracis Ames and Bacillus atrophaeus inoculated onto several types of materials. Pilot-scale tests were also conducted using a larger chamber furnished as an indoor office. Commercial off-the-shelf (COTS) humidifiers filled with aqueous solutions of 3% or 8% hydrogen peroxide were used to generate the HPV inside the mock office. The spores were exposed to the HPV for periods ranging from 8 hours up to one week. Conclusions: Four to seven day exposures to low levels of HPV (average air concentrations of approximately 5-10 parts per million) were effective in inactivating B. anthracis spores on multiple materials. The HPV can be generated with COTS humidifiers and household H2O2 solutions. With the exception of one test/material, B. atrophaeus spores were equally or more resistant to HPV inactivation compared to those from B. anthracis Ames. Significance and Impact of Study: This simple and effective decontamination method is another option that could be widely applied in the event of a B. anthracis spore release.
Assessing cost and effectiveness of radiation decontamination in Fukushima Prefecture, Japan.
Yasutaka, Tetsuo; Naito, Wataru
2016-01-01
Despite the enormous cost of radiation decontamination in Fukushima Prefecture, it is not clear what levels of reduction in external radiation exposure are possible in the Special Decontamination Area, the Intensive Contamination Survey Areas and the whole of Fukushima. The objective of this study was to evaluate the cost and effectiveness of radiation decontamination in Fukushima Prefecture in its entirety. Using a geographic information system, we calculated the costs of removal, storage containers, transport, and temporary and interim storage facilities as well as the reduction in air dose rate for a cumulative external exposure for 9000 1 km × 1 km mesh units incorporating 51 municipalities. The decontamination cost for the basic scenario, for which forested areas within 20 m of habitation areas were decontaminated, was JPY2.53-5.12 trillion; the resulting reduction in annual external dose was about 2500 person-Sv. The transport, storage, and administrative costs of decontamination waste and removed soil reached JPY1.55-2.12 trillion under this scenario. Although implementing decontamination of all forested areas provides some major reductions in the external radiation dose for the average inhabitant, decontamination costs could potentially exceed JPY16 trillion. These results indicate that technologies for reducing the volume of decontamination waste and removed soil should be considered to reduce storage costs and that further discussions about forest decontamination policies are needed. Copyright © 2015 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vogt
This report describes a U.S. Department of Energy, (DOE) Chemical and Biological National Security Program project that sought to establish what is known about decontamination of structures, objects, and people following an exposure to chemical or biological materials. Specifically we sought to identify the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the factorsmore » determining when people were (or were not) decontaminated, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who were decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.« less
Water treatment by the AC gliding arc air plasma
NASA Astrophysics Data System (ADS)
Gharagozalian, Mehrnaz; Dorranian, Davoud; Ghoranneviss, Mahmood
2017-09-01
In this study, the effects of gliding arc (G Arc) plasma system on the treatment of water have been investigated experimentally. An AC power supply of 15 kV potential difference at 50 Hz frequency was employed to generate plasma. Plasma density and temperature were measured using spectroscopic method. The water was contaminated with staphylococcus aureus (Gram-positive) and salmonella bacteria (Gram-negative), and Penicillium (mold fungus) individually. pH, hydrogen peroxide, and nitride contents of treated water were measured after plasma treatment. Decontamination of treated water was determined using colony counting method. Results indicate that G Arc plasma is a powerful and green tool to decontaminate water without producing any byproducts.
Purge- and intensive-purge decontamination of dental units contaminated with biofilm
Kramer, Axel; Assadian, Ojan; Bachfeld, Danny; Meyer, Georg
2012-01-01
Introduction: During hygienic-microbiological monitoring of the water quality in dental units, the total bacterial colony count was found to exceed the limits for drinking water quality; in addition, mold contamination was detected. The presumed cause was irregular decontamination of the units through purging and intensive decontamination. Methods: To decontaminate the units, the manufacturer’s recommended program for cleaning and intensive decontamination was intensified by shortened intervals over a 2-week period. For Sirona units, instead of once a day, the automatic purge program was run every morning and evening for 20 min each time, and instead of once a month, intensive decontamination was performed every two weeks; this schedule has been maintained since then. For KaVo units, cleaning with the hydroclean function was carried out for 2.5 min every morning and evening. The automatic intensive decontamination was run daily instead of weekly. A maintenance log book was introduced, in which decontamination/cleaning was confirmed by the operator’s signature. Results: Within 5 weeks, all previously contaminated units were decontaminated. Discussion: By shortening the cleaning and intensive decontamination intervals in a 2-week period with subsequent control that the recommended maintenance intervals were kept, it was possible to guarantee drinking-water quality in the dental units of both manufacturers. PMID:22558045
Cuypers, Eva; Flinders, Bryn; Boone, Carolien M; Bosman, Ingrid J; Lusthof, Klaas J; Van Asten, Arian C; Tytgat, Jan; Heeren, Ron M A
2016-03-15
Today, hair testing is considered to be the standard method for the detection of chronic drug abuse. Nevertheless, the differentiation between systemic exposure and external contamination remains a major challenge in the forensic interpretation of hair analysis. Nowadays, it is still impossible to directly show the difference between external contamination and use-related incorporation. Although the effects of washing procedures on the distribution of (incorporated) drugs in hair remain unknown, these decontamination procedures prior to hair analysis are considered to be indispensable in order to exclude external contamination. However, insights into the effect of decontamination protocols on levels and distribution of drugs incorporated in hair are essential to draw the correct forensic conclusions from hair analysis; we studied the consequences of these procedures on the spatial distribution of cocaine in hair using imaging mass spectrometry. Additionally, using metal-assisted secondary ion mass spectrometry, we are the first to directly show the difference between cocaine-contaminated and user hair without any prior washing procedure.
Szabo, Jeff; Minamyer, Scott
2014-11-01
This report summarizes the current state of knowledge on the persistence of radiological agents on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some important radiological agents (cesium, strontium and cobalt), but important data gaps remain. Although some targeted experiments have been published on cesium, strontium and cobalt persistence on drinking water infrastructure, most of the data comes from nuclear clean-up sites. Furthermore, the studies focused on drinking water systems use non-radioactive surrogates. Non-radioactive cobalt was shown to be persistent on iron due to oxidation with free chlorine in drinking water and precipitation on the iron surface. Decontamination with acidification was an effective removal method. Strontium persistence on iron was transient in tap water, but adherence to cement-mortar has been demonstrated and should be further explored. Cesium persistence on iron water infrastructure was observed when flow was stagnant, but not with water flow present. Future research suggestions focus on expanding the available cesium, strontium and cobalt persistence data to other common infrastructure materials, specifically cement-mortar. Further exploration chelating agents and low pH treatment is recommended for future decontamination studies. Published by Elsevier Ltd.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zegger, J.L.; Pancer, G.P.
1959-02-15
The caustic permanganante-rinse decontamination studies were performed to determine optimum operating conditions as well as the metallurgical effects of the treatment. A treatment with 10% NaOH and 5% potassium by a rinse with a 5% ammorium citrate, 2% citric acid and 1/2% Versene solution was chosen for the decontamination of a stainless steel steam generator, Decontamination factors of greater than 50 were obtained in loop tests using the above treatment. Corrosion and metallurgical results indicated a total penetration of less than 0.01 mil on annealed type 304 stainless steel with no evidence of any deleterious effects. (auth)
Non-destructive decontamination of building materials
NASA Astrophysics Data System (ADS)
Holecek, Josef; Otahal, Petr
2015-11-01
For nondestructive radiation decontamination of surfaces it is necessary to use varnishes, such as ARGONNE, DG1101, DG1108, etc. This text evaluates the use of manufactured strippable coatings for radiation decontamination. To evaluate decontamination capability of such coatings the following varnishes were selected and subsequently used: AZ 1-700 and AXAL 1807S. The varnishes were tested on different building materials surfaces contaminated by short-term radioisotopes of Na-24 or La-140, in water soluble or water insoluble forms. Decontamination quality was assessed by the decontamination efficiency value, defined as the proportion of removed activity to the applied activity. It was found that decontamination efficiency of both used varnishes depends not only on the form of contaminant, but in the case of application of AXAL 1807S varnish it also depends on the method of its application on the contaminated surface. The values of the decontamination efficiency for AZ1-700 varnish range from 46% for decontamination of a soluble form of the radioisotope from concrete surface to 98% for the decontamination of a soluble form of the radioisotope from ceramic tile surface. The decontamination efficiency values determined for AXAL 1807S varnish range from 48% for decontamination of a soluble form of the radioisotope from concrete surface to 96% for decontamination of an insoluble form of the radioisotope from ceramic tile surface. Comparing these values to the values given for the decontaminating varnishes we can conclude that AXAL 1807S varnish is possible to use on all materials, except highly porous materials, such as plasterboard or breeze blocks, or plastic materials. AZ 1-700 varnish can be used for all dry materials except plasterboard.
Potential biodefense model applications for portable chlorine dioxide gas production.
Stubblefield, Jeannie M; Newsome, Anthony L
2015-01-01
Development of decontamination methods and strategies to address potential infectious disease outbreaks and bioterrorism events are pertinent to this nation's biodefense strategies and general biosecurity. Chlorine dioxide (ClO2) gas has a history of use as a decontamination agent in response to an act of bioterrorism. However, the more widespread use of ClO2 gas to meet current and unforeseen decontamination needs has been hampered because the gas is too unstable for shipment and must be prepared at the application site. Newer technology allows for easy, onsite gas generation without the need for dedicated equipment, electricity, water, or personnel with advanced training. In a laboratory model system, 2 unique applications (personal protective equipment [PPE] and animal skin) were investigated in the context of potential development of decontamination protocols. Such protocols could serve to reduce human exposure to bacteria in a decontamination response effort. Chlorine dioxide gas was capable of reducing (2-7 logs of vegetative and spore-forming bacteria), and in some instances eliminating, culturable bacteria from difficult to clean areas on PPE facepieces. The gas was effective in eliminating naturally occurring bacteria on animal skin and also on skin inoculated with Bacillus spores. The culturable bacteria, including Bacillus spores, were eliminated in a time- and dose-dependent manner. Results of these studies suggested portable, easily used ClO2 gas generation systems have excellent potential for protocol development to contribute to biodefense strategies and decontamination responses to infectious disease outbreaks or other biothreat events.
Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan
2012-01-01
Background: A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean® technology, based on anodic oxidation. Method: The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean® (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. Results: After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean® was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. Discussion: An important factor for the efficacy of PotoClean® was the age of the units and their construction. For a new generation of dental units PotoClean® was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. Conclusion: The PotoClean® technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean® and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable. PMID:22558044
Electrolytic decontamination of conductive materials
NASA Astrophysics Data System (ADS)
Campbell, George M.; Nelson, Timothy O.; Parker, John L.; Getty, Richard H.; Hergert, Tom R.; Lindahl, Kirk A.; Peppers, Larry G.
1994-10-01
Using the electrolytic method, we have demonstrated removal of Pu and Am from contaminated conductive material. At EG and G /Rocky Flats, we electrolytically decontaminated stainless steel. Results from this work show removal of fixed contamination, including the following geometries: planar, large radius, bolt holes, glove ports, and protruding studs. More specifically, fixed contamination was reduced from levels ranging from greater than 1 000 000 counts per minute (cpm) down to levels ranging from 1500 to 250 cpm using the electrolytic method. More recently, the electrolytic work has continued at Los Alamos National Laboratory as a joint project with EG and G/Rocky Flats. Impressively, electrolytic decontamination of Pu /Am from U surfaces (10 sq cm per side) shows decreases in swipable contamination from 500 000-1 500 000 disintegrations per minute (dpm) down to 0-2 dpm. Moreover, the solid waste product of the electrolytic method is reduced in volume by more than 50 times compared with the liquid waste produced by the previous U decontamination method -- a hot concentrated acid spray leach process.
Development of practical decontamination process for the removal of uranium from gravel.
Kim, Ilgook; Kim, Gye-Nam; Kim, Seung-Soo; Choi, Jong-Won
2018-01-01
In this study, a practical decontamination process was developed to remove uranium from gravel using a soil washing method. The effects of critical parameters including particle size, H 2 SO 4 concentration, temperature, and reaction time on uranium removal were evaluated. The optimal condition for two-stage washing of gravel was found to be particle size of 1-2 mm, 1.0 M H 2 SO 4 , temperature of 60°C, and reaction time of 3 h, which satisfied the required uranium concentration for self-disposal. Furthermore, most of the extracted uranium was removed from the waste solution by precipitation, implying that the treated solution can be reused as washing solution. These results clearly demonstrated that our proposed process can be indeed a practical technique to decontaminate uranium-polluted gravel.
Hopkins, F B; Gravett, M R; Self, A J; Wang, M; Chua, Hoe-Chee; Hoe-Chee, C; Lee, H S Nancy; Sim, N Lee Hoi; Jones, J T A; Timperley, C M; Riches, J R
2014-08-01
Detailed chemical analysis of solutions used to decontaminate chemical warfare agents can be used to support verification and forensic attribution. Decontamination solutions are amongst the most difficult matrices for chemical analysis because of their corrosive and potentially emulsion-based nature. Consequently, there are relatively few publications that report their detailed chemical analysis. This paper describes the application of modern analytical techniques to the analysis of decontamination solutions following decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). We confirm the formation of N,N-diisopropylformamide and N,N-diisopropylamine following decontamination of VX with hypochlorite-based solution, whereas they were not detected in extracts of hydroxide-based decontamination solutions by nuclear magnetic resonance (NMR) spectroscopy or gas chromatography-mass spectrometry. We report the electron ionisation and chemical ionisation mass spectroscopic details, retention indices, and NMR spectra of N,N-diisopropylformamide and N,N-diisopropylamine, as well as analytical methods suitable for their analysis and identification in solvent extracts and decontamination residues.
Decontamination of dental implant surface in peri-implantitis treatment: A literature review
Buitrago-Vera, Pedro; Solá-Ruiz, María F.; Ferrer-García, Juan C.
2013-01-01
Etiological treatment of peri-implantitis aims to reduce the bacterial load within the peri-implant pocket and decontaminate the implant surface in order to promote osseointegration. The aim of this literature review was to evaluate the efficacy of different methods of implant surface decontamination. A search was conducted using the PubMed (Medline) database, which identified 36 articles including in vivo and in vitro studies, and reviews of different decontamination systems (chemical, mechanical, laser and photodynamic therapies). There is sufficient consensus that, for the treatment of peri-implant infections, the mechanical removal of biofilm from the implant surface should be supplemented by chemical decontamination with surgical access. However, more long-term research is needed to confirm this and to establish treatment protocols responding to different implant characterics. Key words:Peri-implantitis, treatment, decontamination, implant surface, laser. PMID:23986023
Koenig, Kristi L; Boatright, Connie J; Hancock, John A; Denny, Frank J; Teeter, David S; Kahn, Christopher A; Schultz, Carl H
2008-01-01
Since the US terrorist attacks of September 11, 2001, concern regarding use of chemical, biological, or radiological weapons is heightened. Many victims of such an attack would present directly to health care facilities without first undergoing field decontamination. This article reviews basic tenets and recommendations for health care facility-based decontamination, including regulatory concerns, types of contaminants, comprehensive decontamination procedures (including crowd control, triage, removal of contaminated garments, cleaning of body contaminants, and management of contaminated materials and equipment), and a discussion of methods to achieve preparedness.
Small-Item Vapor Test Method, FY11 Release
2012-07-01
to this test procedure is provided alphabetically in the following list: absorption: The uptake of a contaminant INTO the volume of a material. The... powders , wipes), or gas-phase (fumigants, including aerosols). decontamination process: The process of making any person, object, or area safe by...with another contaminant. Generally, bare metals and glass are nonsorptive materials for some agents. operational decontamination: Decontamination
Curtis, Henry A; Trang, Karen; Chason, Kevin W; Biddinger, Paul D
2018-02-01
Introduction Great demands have been placed on disaster medicine educators. There is a need to develop innovative methods to educate Emergency Physicians in the ever-expanding body of disaster medicine knowledge. The authors sought to demonstrate that video-based learning (VBL) could be a promising alternative to traditional learning methods for teaching disaster medicine core competencies. Hypothesis/Problem The objective was to compare VBL to traditional lecture (TL) for instructing Emergency Medicine residents in the American College of Emergency Physicians (ACEP; Irving, Texas USA) disaster medicine core competencies of patient triage and decontamination. A randomized, controlled pilot study compared two methods of instruction for mass triage, decontamination, and personal protective equipment (PPE). Emergency Medicine resident learning was measured with a knowledge quiz, a Likert scale measuring comfort, and a practical exercise. An independent samples t-test compared the scoring of the VBL with the TL group. Twenty-six residents were randomized to VBL (n=13) or TL (n=13). Knowledge score improvement following video (14.9%) versus lecture (14.1%) did not differ significantly between the groups (P=.74). Comfort score improvement also did not differ (P=.64) between video (18.3%) and lecture groups (15.8%). In the practical skills assessment, the VBL group outperformed the TL group overall (70.4% vs 55.5%; P<.0001), with significantly better performance in donning PPE and decontamination. Although not part of the original study design, a three-month post-hoc analysis was performed. When comparing the pre-intervention and three-month post-hoc performances, there were no significant differences in knowledge increases between VBL versus TL (P=.41) or in comfort (P=.39). Video modules can be as effective as TL when utilized to train Emergency Medicine residents in the ACEP disaster medicine core competencies of patient triage and decontamination. Curtis HA , Trang K , Chason KW , Biddinger PD . Video-based learning vs traditional lecture for instructing emergency medicine residents in disaster medicine principles of mass triage, decontamination, and personal protective equipment. Prehosp Disaster Med. 2018;33(1):7-12.
RSDL decontamination of human skin contaminated with the nerve agent VX.
Thors, L; Lindberg, S; Johansson, S; Koch, B; Koch, M; Hägglund, L; Bucht, A
2017-03-05
Dermal exposure to low volatile organophosphorus compounds (OPC) may lead to penetration through the skin and uptake in the blood circulation. Skin decontamination of toxic OPCs, such as pesticides and chemical warfare nerve agents, might therefore be crucial for mitigating the systemic toxicity following dermal exposure. Reactive skin decontamination lotion (RSDL) has been shown to reduce toxic effects in animals dermally exposed to the nerve agent VX. In the present study, an in vitro flow-through diffusion cell was utilized to evaluate the efficacy of RSDL for decontamination of VX exposed to human epidermis. In particular, the impact of timing in the initiation of decontamination and agent dilution in water was studied. The impact of the lipophilic properties of VX in the RSDL decontamination was additionally addressed by comparing chemical degradation in RSDL and decontamination efficacy between the VX and the hydrophilic OPC triethyl phosphonoacetate (TEPA). The epidermal membrane was exposed to 20, 75 or 90% OPC diluted in deionized water and the decontamination was initiated 5, 10, 30, 60 or 120min post-exposure. Early decontamination of VX with RSDL, initiated 5-10min after skin exposure, was very effective. Delayed decontamination initiated 30-60min post-exposure was less effective but still the amount of penetrated agent was significantly reduced, while further delayed start of decontamination to 120min resulted in very low efficacy. Comparing RSDL decontamination of VX with that of TEPA showed that the decontamination efficacy at high agent concentrations was higher for VX. The degradation mechanism of VX and TEPA during decontamination was dissected by 31 P NMR spectroscopy of the OPCs following reactions with RSDL and its three nucleophile components. The degradation rate was clearly associated with the high pH of the specific solution investigated; i.e. increased pH resulted in a more rapid degradation. In addition, the solubility of the OPC in RSDL also influenced the degradation rate since the degradation of VX was significantly faster when the NMR analysis was performed in the organic solvent acetonitrile compared to water. In conclusion, we have applied the in vitro flow-through diffusion cell for evaluation of skin decontamination procedures of human epidermis exposed to OPCs. It was demonstrated that early decontamination is crucial for efficient mitigation of epidermal penetration of VX and that almost complete removal of the nerve agent from the skin surface is possible. Our data also indicate that the pH of RSDL together with the solubility of OPC in RSDL are of primary importance for the decontamination efficacy. Copyright © 2017 Elsevier B.V. All rights reserved.
Chemical Decontaminant Testing
2014-10-20
make certain that the amine group on the VX is entirely in the freebase form needed for complete extraction into the chloroform. (3) When other...information, including suggestions for reducing this burden, to Department of Defense, Washington Headquarters Services, Directorate for information on ...material effects of decontaminants on fielded military equipment (material effects are defined as hardness). Mechanisms of decontaminating equipment
2011-01-01
Introduction Given the high morbidity and mortality attributable to ventilator-associated pneumonia (VAP) in intensive care unit (ICU) patients, prevention plays a key role in the management of patients undergoing mechanical ventilation. One of the candidate preventive interventions is the selective decontamination of the digestive or respiratory tract (SDRD) by topical antiseptic or antimicrobial agents. We performed a meta-analysis to investigate the effect of topical digestive or respiratory tract decontamination with antiseptics or antibiotics in the prevention of VAP, of mortality and of all ICU-acquired infections in mechanically ventilated ICU patients. Methods A meta-analysis of randomised controlled trials was performed. The U.S. National Library of Medicine's MEDLINE database, Embase, and Cochrane Library computerized bibliographic databases, and reference lists of selected studies were used. Selection criteria for inclusion were: randomised controlled trials (RCTs); primary studies; examining the reduction of VAP and/or mortality and/or all ICU-acquired infections in ICU patients by prophylactic use of one or more of following topical treatments: 1) oropharyngeal decontamination using antiseptics or antibiotics, 2) gastrointestinal tract decontamination using antibiotics, 3) oropharyngeal plus gastrointestinal tract decontamination using antibiotics and 4) respiratory tract decontamination using antibiotics; reported enough data to estimate the odds ratio (OR) or risk ratio (RR) and their variance; English language; published through June 2010. Results A total of 28 articles met all inclusion criteria and were included in the meta-analysis. The overall estimate of efficacy of topical SDRD in the prevention of VAP was 27% (95% CI of efficacy = 16% to 37%) for antiseptics and 36% (95% CI of efficacy = 18% to 50%) for antibiotics, whereas in none of the meta-analyses conducted on mortality was a significant effect found. The effect of topical SDRD in the prevention of all ICU-acquired infections was statistically significant (efficacy = 29%; 95% CI of efficacy = 14% to 41%) for antibiotics whereas the use of antiseptics did not show a significant beneficial effect. Conclusions Topical SDRD using antiseptics or antimicrobial agents is effective in reducing the frequency of VAP in ICU. Unlike antiseptics, the use of topical antibiotics seems to be effective also in preventing all ICU-acquired infections, while the effectiveness on mortality of these two approaches needs to be investigated in further research. PMID:21702946
To support the Nation's Homeland Security Program, this U.S. Environmental Protection Agency (EPA) Environmental Technology Verification (ETV) project is conducted to verify the performance of commercially available products, methods, and equipment for decontamination of hard and...
Nuclear reactor cooling system decontamination reagent regeneration. [PWR; BWR
Anstine, L.D.; James, D.B.; Melaika, E.A.; Peterson, J.P. Jr.
1980-06-06
An improved method for decontaminating the coolant system of water-cooled nuclear power reactors and for regenerating the decontamination solution is described. A small amount of one or more weak-acid organic complexing agents is added to the reactor coolant, and the pH is adjusted to form a decontamination solution which is circulated throughout the coolant system to dissolve metal oxides from the interior surfaces and complex the resulting metal ions and radionuclide ions. The coolant containing the complexed metal ions and radionuclide ions is passed through a strong-base anion exchange resin bed which has been presaturated with a solution containing the complexing agents in the same ratio and having the same pH as the decontamination solution. As the decontamination solution passes through the resin bed, metal-complexed anions are exchanged for the metal-ion-free anions on the bed, while metal-ion-free anions in the solution pass through the bed, thus removing the metal ions and regenerating the decontamination solution.
Nuclear reactor cooling system decontamination reagent regeneration
Anstine, Larry D.; James, Dean B.; Melaika, Edward A.; Peterson, Jr., John P.
1985-01-01
An improved method for decontaminating the coolant system of water-cooled nuclear power reactors and for regenerating the decontamination solution. A small amount of one or more weak-acid organic complexing agents is added to the reactor coolant, and the pH is adjusted to form a decontamination solution which is circulated throughout the coolant system to dissolve metal oxides from the interior surfaces and complex the resulting metal ions and radionuclide ions. The coolant containing the complexed metal ions and radionuclide ions is passed through a strong-base anion exchange resin bed which has been presaturated with a solution containing the complexing agents in the same ratio and having the same pH as the decontamination solution. As the decontamination solution passes through the resin bed, metal-complexed anions are exchanged for the metal-ion-free anions on the bed, while metal-ion-free anions in the solution pass through the bed, thus removing the metal ions and regenerating the decontamination solution.
Fang, Hsin-Fa; Wang, Chu-Fang; Lin, Chien-Kung
2015-12-01
It is important that monitoring environmental tritiated water for understanding the contamination dispersion of the nuclear facilities. Tritium is a pure beta radionuclide which is usually measured by Liquid Scintillation Counting (LSC). The average energy of tritum beta is only 5.658 keV that makes the LSC counting of tritium easily be interfered by the beta emitted by other radionuclides. Environmental tritiated water samples usually need to be decontaminated by distillation for reducing the interference. After Fukushima Nucleaer Accident, the highest gross beta concentration of groundwater samples obtained around Fukushima Daiichi Nuclear Power Station is over 1,000,000 Bq/l. There is a need for a distillation with ultra-high decontamination efficiency for environmental tritiated water analysis. This study is intended to improve the heating temperature control for better sub-boiling distillation control and modify the height of the container of the air cooling distillation device for better fractional distillation effect. The DF of Cs-137 of the distillation may reach 450,000 which is far better than the prior study. The average loss rate of the improved method and device is about 2.6% which is better than the bias value listed in the ASTM D4107-08. It is proven that the modified air cooling distillation device can provide an easy-handling, water-saving, low cost and effective way of purifying water samples for higher beta radionuclides contaminated water samples which need ultra-high decontamination treatment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Studies on residue-free decontaminants for chemical warfare agents.
Wagner, George W
2015-03-17
Residue-free decontaminants based on hydrogen peroxide, which decomposes to water and oxygen in the environment, are examined as decontaminants for chemical warfare agents (CWA). For the apparent special case of CWA on concrete, H2O2 alone, without any additives, effectively decontaminates S-2-(diisopropylamino)ethyl O-ethyl methylphosphonothioate (VX), pinacolyl methylphosphorofluoridate (GD), and bis(2-choroethyl) sulfide (HD) in a process thought to involve H2O2 activation by surface-bound carbonates/bicarbonates (known H2O2 activators for CWA decontamination). A plethora of products are formed during the H2O2 decontamination of HD on concrete, and these are characterized by comparison to synthesized authentic compounds. As a potential residue-free decontaminant for surfaces other than concrete (or those lacking adsorbed carbonate/bicarbonate) H2O2 activation for CWA decontamination is feasible using residue-free NH3 and CO2 as demonstrated by reaction studies for VX, GD, and HD in homogeneous solution. Although H2O2/NH3/CO2 ("HPAC") decontaminants are active for CWA decontamination in solution, they require testing on actual surfaces of interest to assess their true efficacy for surface decontamination.
Field Equipment Cleaning and Decontamination
EPA Region 4 Science and Ecosystem Support Division (SESD), Nov. 1, 2007, document describes general and specific procedures, methods and considerations when cleaning and decontaminating sampling equipment during the course of field investigations.
40 CFR 761.378 - Decontamination, reuse, and disposal of solvents, cleaners, and equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
... PROTECTION AGENCY (CONTINUED) TOXIC SUBSTANCES CONTROL ACT POLYCHLORINATED BIPHENYLS (PCBs) MANUFACTURING, PROCESSING, DISTRIBUTION IN COMMERCE, AND USE PROHIBITIONS Double Wash/Rinse Method for Decontaminating Non...
Contamination control by use of ethylene oxide
NASA Technical Reports Server (NTRS)
Stroud, R. H.; Lyle, R. G.
1972-01-01
The uses of ethylene oxide as a decontaminating agent for planetary quarantine related applications are reported. Aspects discussed include: applications and limitations, chemical and physical properties, germicidal activity, methods of applications, and effects on personnel.
Han, Changhee; Burn-Nunes, Laurie J; Lee, Khanghyun; Chang, Chaewon; Kang, Jung-Ho; Han, Yeongcheol; Hur, Soon Do; Hong, Sungmin
2015-08-01
An improved decontamination method and ultraclean analytical procedures have been developed to minimize Pb contamination of processed glacial ice cores and to achieve reliable determination of Pb isotopes in North Greenland Eemian Ice Drilling (NEEM) deep ice core sections with concentrations at the sub-picogram per gram level. A PL-7 (Fuso Chemical) silica-gel activator has replaced the previously used colloidal silica activator produced by Merck and has been shown to provide sufficiently enhanced ion beam intensity for Pb isotope analysis for a few tens of picograms of Pb. Considering the quantities of Pb contained in the NEEM Greenland ice core and a sample weight of 10 g used for the analysis, the blank contribution from the sample treatment was observed to be negligible. The decontamination and analysis of the artificial ice cores and selected NEEM Greenland ice core sections confirmed the cleanliness and effectiveness of the overall analytical process. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Scholtz, V.; Khun, J.; Soušková, H.; Čeřovský, M.
2015-07-01
The inactivation effect of nonthermal plasma generated in electric discharge burning in air atmosphere with water or hydrogen peroxide aerosol for the application to the microbial decontamination of packaging foils is studied. The microbial inactivation is studied on two bacterial, two yeasts, and two filamentous micromycete species. The inactivation of all contaminating microorganisms becomes on the area of full 8.5 cm in diameter circular sample after short times of several tens of seconds. Described apparatus may present a possible alternative method of microbial decontamination of food packaging material or other thermolabile materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholtz, V., E-mail: Vladimir.Scholtz@vscht.cz; Khun, J.; Soušková, H.
The inactivation effect of nonthermal plasma generated in electric discharge burning in air atmosphere with water or hydrogen peroxide aerosol for the application to the microbial decontamination of packaging foils is studied. The microbial inactivation is studied on two bacterial, two yeasts, and two filamentous micromycete species. The inactivation of all contaminating microorganisms becomes on the area of full 8.5 cm in diameter circular sample after short times of several tens of seconds. Described apparatus may present a possible alternative method of microbial decontamination of food packaging material or other thermolabile materials.
Mahato, T H; Singh, Beer; Srivastava, A K; Prasad, G K; Srivastava, A R; Ganesan, K; Vijayaraghavan, R
2011-09-15
Present study investigates the potential of CuO nanoparticles calcined at different temperature for the decontamination of persistent chemical warfare agent sulphur mustard (HD) at room temperature (30 ± 2 °C). Nanoparticles were synthesized by precipitation method and characterized by using SEM, EDAX, XRD, and Raman Spectroscopy. Synthesized nanoparticles were tested as destructive adsorbents for the degradation of HD. Reactions were monitored by GC-FID technique and the reaction products characterized by GC-MS. It was observed that the rate of degradation of HD decreases with the increase in calcination temperature and there is a change in the percentage of product of HD degradation. GC-MS data indicated that the elimination product increases with increase in calcination temperature whereas the hydrolysis product decreases. Copyright © 2011 Elsevier B.V. All rights reserved.
1988-11-01
results. On the contrary, the active decon moiety in both cases is the hydroxyl ion (0OH), and the agent being decontaminated reacts exactly the same...methods. A review of method3 utilized to determine the concentration of active material before and after the decontamination process. Included are the most...isolation of acid A, acid B will probably be excluded by the forces active in the crystallization process. Acid B will therefore be missed in the overall
Salerno, Alicia; Devers, Thierry; Bolzinger, Marie-Alexandrine; Pelletier, Jocelyne; Josse, Denis; Briançon, Stéphanie
2017-04-01
Organophosphorus compounds (OP), which mainly penetrate via the percutaneous pathway, represent a threat for both military and civilians. Body surface decontamination is vital to prevent victims poisoning. The development of a cost-effective formulation, which could be efficient and easy to handle in case of mass contamination, is therefore crucial. Metal oxides nanoparticles, due their large surface areas and the large amount of highly reactive sites, present high reactivity towards OP. First, this study aimed at evaluating the reaction of CeO 2 nanoparticles, synthetized by microwave path and calcined at 500 or 600 °C, with Paraoxon (POX) in aqueous solution. Results showed that both nanoparticles degraded 60%-70% of POX. CeO 2 calcined at 500 °C, owing to its larger specific area, was the most effective. Moreover, the degradation was significantly increased under Ultra-Violet irradiation (initial degradation rate doubled). Then, skin decontamination was studied in vitro using the Franz cell method with pig-ear skin samples. CeO 2 powder and an aqueous suspension of CeO 2 (CeO 2 -W) were applied 1 h after POX exposure. The efficiency of decontamination, including removal and/or degradation of POX, was compared to Fuller's earth (FE) and RSDL lotion which are, currently, the most efficient systems for skin decontamination. CeO 2 -W and RSDL were the most efficient to remove POX from the skin surface and decrease skin absorption by 6.4 compared to the control not decontaminated. FE reduced significantly (twice) the absorbed fraction of POX, contrarily to CeO 2 powder. Considering only the degradation rate of POX, the products ranged in the order CeO 2 > RSDL > CeO 2 -W > FE (no degradation). This study showed that CeO 2 nanoparticles are a promising material for skin decontamination of OP if formulated as a dispersion able to remove POX like CeO 2 -W and to degrade it as CeO 2 powder. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Enhanced toxic cloud knockdown spray system for decontamination applications
Betty, Rita G [Rio Rancho, NM; Tucker, Mark D [Albuquerque, NM; Brockmann, John E [Albuquerque, NM; Lucero, Daniel A [Albuquerque, NM; Levin, Bruce L [Tijeras, NM; Leonard, Jonathan [Albuquerque, NM
2011-09-06
Methods and systems for knockdown and neutralization of toxic clouds of aerosolized chemical or biological warfare (CBW) agents and toxic industrial chemicals using a non-toxic, non-corrosive aqueous decontamination formulation.
Effects of soap-water wash on human epidermal penetration.
Zhu, Hanjiang; Jung, Eui-Chang; Phuong, Christina; Hui, Xiaoying; Maibach, Howard
2016-08-01
Skin decontamination is a primary interventional method used to decrease dermal absorption of hazardous contaminants, including chemical warfare agents, pesticides and industrial pollutants. Soap and water wash, the most common and readily available decontamination system, may enhance percutaneous absorption through the "wash-in effect." To understand better the effect of soap-water wash on percutaneous penetration, and provide insight to improving skin decontamination methods, in vitro human epidermal penetration rates of four C(14) -labeled model chemicals (hydroquinone, clonidine, benzoic acid and paraoxon) were assayed using flow-through diffusion cells. Stratum corneum (SC) absorption rates of these chemicals at various hydration levels (0-295% of the dry SC weights) were determined and compared with the results of the epidermal penetration study to clarify the effect of SC hydration on skin permeability. Results showed accelerated penetration curves of benzoic acid and paraoxon after surface wash at 30 min postdosing. Thirty minutes after washing (60 min postdosing), penetration rates of hydroquinone and benzoic acid decreased due to reduced amounts of chemical on the skin surface and in the SC. At the end of the experiment (90 min postdosing), a soap-water wash resulted in lower hydroquinone penetration, greater paraoxon penetration and similar levels of benzoic acid and clonidine penetration compared to penetration levels in the non-wash groups. The observed wash-in effect agrees with the enhancement effect of SC hydration on the SC chemical absorption rate. These results suggest SC hydration derived from surface wash to be one cause of the wash-in effect. Further, the occurrence of a wash-in effect is dependent on chemical identity and elapsed time between exposure and onset of decontamination. By reducing chemical residue quantity on skin surface and in the SC reservoir, the soap-water wash may decrease the total quantity of chemical absorbed in the long term; however, the more immediate accelerated absorption of chemical toxins, particularly chemical warfare agents, may be lethal. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Timing of decontamination and treatment in case of percutaneous VX poisoning: a mini review.
Joosen, Marloes J A; van der Schans, Marcel J; Kuijpers, Willem C; van Helden, Herman P M; Noort, Daan
2013-03-25
Low volatile organophosphorous nerve agents such as VX, will most likely enter the body via the skin. The pharmacokinetics of drugs such as oximes, atropine and diazepam, are not aligned with the variable and persistent toxicokinetics of the agent. Repeated administration of these drugs showed to improve treatment efficacy compared to a single injection treatment. Because of the effectiveness of continuous treatment, it was investigated to what extent a subchronic pretreatment with carbamate (pyridostigmine or physostigmine combined with either procyclidine or scopolamine) would protect against percutaneous VX exposure. Inclusion of scopolamine in the pretreatment prevented seizures in all animals, but none of the pretreatments affected survival time or the onset time of cholinergic signs. These results indicate that percutaneous poisoning with VX requires additional conventional treatment in addition to the current pretreatment regimen. Decontamination of VX-exposed skin is one of the most important countermeasures to mitigate the effects of the exposure. To evaluate the window of opportunity for decontamination, the fielded skin decontaminant Reactive Skin Decontaminant Lotion (RSDL) was tested at different times in hairless guinea pigs percutaneously challenged with 4× LD50 VX in IPA. The results showed that RSDL decontamination at 15 min after exposure could not prevent progressive blood cholinesterase inhibition and therefore would still require additional treatment. A similar decontamination regimen with RSDL at 90 min showed that it still might effectively increase the time window of opportunity for treatment. In conclusion, the delay in absorption presents a window of opportunity for decontamination and treatment. The continuous release of VX from the skin presents a significant challenge for efficacious therapy, which should ideally consist of thorough decontamination and continuous treatment. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Herrmann, Hans W.
1998-11-01
The atmospheric pressure plasma jet (APPJ) is a non-thermal, high pressure, uniform glow discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g. He/O_2/H_2O) which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz RF. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains metastables (e.g. O2*, He*) and radicals (e.g. O, OH). These reactive species have been shown to be effective neutralizers of surrogates for anthrax spores, mustard blister agent and VX nerve gas. Unlike conventional, wet decontamination methods, the plasma effluent does not cause corrosion of most surfaces and does not damage wiring, electronics, nor most plastics. This makes it highly suitable for decontamination of high value sensitive equipment such as is found in vehicle interiors (i.e. tanks, planes...) for which there is currently no good decontamination technique. Furthermore, the reactive species rapidly degrade into harmless products leaving no lingering residue or harmful byproducts. Physics of the APPJ will be discussed and results of surface decontamination experiments using simulant and actual CBW agents will be presented.
Decontamination Efficacy and Skin Toxicity of Two Decontaminants against Bacillus anthracis
Stratilo, Chad W.; Crichton, Melissa K. F.; Sawyer, Thomas W.
2015-01-01
Decontamination of bacterial endospores such as Bacillus anthracis has traditionally required the use of harsh or caustic chemicals. The aim of this study was to evaluate the efficacy of a chlorine dioxide decontaminant in killing Bacillus anthracis spores in solution and on a human skin simulant (porcine cadaver skin), compared to that of commonly used sodium hypochlorite or soapy water decontamination procedures. In addition, the relative toxicities of these decontaminants were compared in human skin keratinocyte primary cultures. The chlorine dioxide decontaminant was similarly effective to sodium hypochlorite in reducing spore numbers of Bacillus anthracis Ames in liquid suspension after a 10 minute exposure. After five minutes, the chlorine dioxide product was significantly more efficacious. Decontamination of isolated swine skin contaminated with Bacillus anthracis Sterne with the chlorine dioxide product resulted in no viable spores sampled. The toxicity of the chlorine dioxide decontaminant was up to two orders of magnitude less than that of sodium hypochlorite in human skin keratinocyte cultures. In summary, the chlorine dioxide based decontaminant efficiently killed Bacillus anthracis spores in liquid suspension, as well as on isolated swine skin, and was less toxic than sodium hypochlorite in cultures of human skin keratinocytes. PMID:26394165
Method and coating composition for protecting and decontaminating surfaces
Overhold, D C; Peterson, M D
1959-03-10
A protective coating useful in the decontamination of surfaces exposed to radioactive substances is described. This coating is placed on the surface before use and is soluble in water, allowing its easy removal in the event decontamination becomes necessary. Suitable coating compositions may be prepared by mixing a water soluble carbohydrate such as sucrose or dextrin, together with a hygroscopic agent such as calcium chloride or zinc chloride.
METHOD AND COATING COMPOSITION FOR PROTECTING AND DECONTAMINATING SURFACES
Overhold, D.C.; Peterson, M.D.
1959-03-10
A protective coating useful in the decontamination of surfaces exposed to radioactive substances is presented. This coating is placed on the surface before use and is soluble in waters allowing its easy removal in the event decontamination becomes necessary. Suitable coating compositions may be prepared by mixing a water soluble carbohydrate such as sucrose or dextrin, together with a hygroscopic agent such as calcium chloride or zinc chloride.
Kumar, M; Hora, R; Kostrzynska, M; Waites, W M; Warriner, K
2006-07-01
The efficacy of a stabilized oxychloro-based food grade sanitizer to decontaminate seeds destined for sprout production has been evaluated. By using mung bean seeds as a model system, it was demonstrated that the sanitizer could be used to inactivate a five-strain cocktail of Escherichia coli O157:H7 or Salmonella introduced onto beans at 10(3) to 10(4) CFU/g. Salmonella was more tolerant to stabilized oxychloro than was E. coli O157:H7, with sanitizer levels of >150 and >50 ppm, respectively, being required to ensure pathogen-free sprouts. The decontamination efficacy was also found to be dependent on treatment time (>8 h optimal) and the seed-to-sanitizer ratio (>1:4 optimal). Stabilized oxychloro treatment did not exhibit phytotoxic effects, as germination and sprout yields were not significantly (P > 0.05) different as compared with untreated controls. Although human pathogens could be effectively eliminated from mung beans, the aerobic plate count of native microflora on sprouts grown from treated seed was not significantly (P > 0.05) different from the controls. The diversity of microbial populations (determined through 16S rRNA denaturing gradient gel electrophoresis analysis) associated with bean sprouts was not significantly affected by the sanitizer treatment. However, it was noted that Klebsiella and Herbasprillum (both common plant endophytes) were absent in sprouts derived from decontaminated seed but were present in control sprouts. When a further range of seed types was evaluated, it was found that alfalfa, cress, flax, and soybean could be decontaminated with the stabilized oxychloro sanitizer. However, the decontamination efficacy with other seed types was less consistent. It appears that the rate of seed germination and putative activity of sanitizer sequestering system(s), in addition to other factors, may limit the efficacy of the decontamination method.
2006-04-01
b. Principles of Decontamination Operations. Decontaminate immediately for an agent on the skin . Perform higher levels of decontamination as a...the mask and hood with paper towels or rags. NOTE: Cool, soapy water is not as effective for removing contamination, but it can be used if you scrub ...N/A N/A 5 N/A Sponge, cellulose II Each As required N/A N/A N/A N/A 2 N/A 4 6 Brush, scrub II Each As required N/A N/A N/A N/A 2 N/A 2 N/A Towels
Metal Surface Decontamination by the PFC Solution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hui-Jun Won; Gye-Nam Kim; Wang-Kyu Choi
2006-07-01
PFC (per-fluorocarbon) spray decontamination equipment was fabricated and its decontamination behavior was investigated. Europium oxide powder was mixed with the isotope solution which contains Co-60 and Cs-137. The different shape of metal specimens artificially contaminated with europium oxide powder was used as the surrogate contaminants. Before and after the application of the PFC spray decontamination method, the radioactivity of the metal specimens was measured by MCA. The decontamination factors were in the range from 9.6 to 62.4. The spent PFC solution was recycled by distillation. Before and after distillation, the turbidity of PFC solution was also measured. From the testmore » results, it was found that more than 98% of the PFC solution could be recycled by a distillation. (authors)« less
Cold Atmospheric Plasma Technology for Decontamination of Space Equipment
NASA Astrophysics Data System (ADS)
Thomas, Hubertus; Rettberg, Petra; Shimizu, Tetsuji; Thoma, Markus; Morfill, Gregor; Zimmermann, Julia; Müller, Meike; Semenov, Igor
2016-07-01
Cold atmospheric plasma (CAP) technology is very fast and effective in inactivation of all kinds of pathogens. It is used in hygiene and especially in medicine, since the plasma treatment can be applied to sensitive surfaces, like skin, too. In a first study to use CAP for the decontamination of space equipment we could show its potential as a quite promising alternative to the standard "dry heat" and H2O2 methods [Shimizu et al. Planetary and Space Science, 90, 60-71. (2014)]. In a follow-on study we continue the investigations to reach high application level of the technology. First, we redesign the actual setup to a plasma-gas circulation system, increasing the effectivity of inactivation and the sustainability. Additionally, we want to learn more about the plasma chemistry processes involved in the inactivation. Therefore, we perform detailed plasma and gas measurements and compare them to numerical simulations. The latter will finally be used to scale the decontamination system to sizes useful also for larger space equipment. Typical materials relevant for space equipment will be tested and investigated on surface material changes due to the plasma treatment. Additionally, it is planned to use electronic boards and compare their functionality before and after the CAP expose. We will give an overview on the status of the plasma decontamination project funded by the Bavarian Ministry of Economics.
Nastou, Aikaterini; Rhoades, Jonathan; Smirniotis, Petros; Makri, Ioanna; Kontominas, Michael; Likotrafiti, Eleni
2012-10-15
The efficacy of household decontamination methods at reducing Listeria monocytogenes on fresh lettuce (Lactuca sativa), cucumber (Cucumis sativus) and parsley (Petroselinum sativum) was studied. Inoculated vegetable pieces were immersed in washing solutions and surviving L. monocytogenes enumerated. Parameters investigated were storage temperature prior to washing, dipping water temperature, agitation, acetic acid concentration and immersion time. The results indicated that the storage temperature significantly affects the efficacy of dipping vegetables in water for the control of L. monocytogenes, as the reduction in count was greatest when products had been stored at cooler temperatures. Decontamination with acetic acid (up to 2.0% v/v) was shown to have some effect in most cases, but the highest observed decrease in count was 2.6 log cfu/g. Experiments investigating the effect of exposure time to acetic acid (0.5% and 1.0% v/v, up to 30 min immersion) indicated that immersing the vegetables for more than 10 min is of minimal benefit. The most significant factor affecting washing and decontamination efficacy was the vegetable itself: L. monocytogenes colonizing cucumber epidermis was far more resistant to removal by washing and to acid treatment than that on the leafy vegetables, and L. monocytogenes on parsley was the most susceptible. This shows that published decontamination experiments (often performed with lettuce) cannot necessarily be extrapolated to other vegetables. Copyright © 2012 Elsevier B.V. All rights reserved.
Lumia, Margaret E.; Gentile, Charles; Gochfeld, Michael; Efthimion, Philip; Robson, Mark
2015-01-01
This study evaluates a new decontamination technique for the mitigation and abatement of hazardous particulates. The traditional decontamination methods used to clean facilities and equipment are time-consuming, prolonging workers' exposure time, may generate airborne hazards, and can be expensive. The use of removable thin film coating as a decontamination technique for surface contamination proved to be a more efficient method of decontamination. This method was tested at three different sites on different hazardous metals. One application of the coating reduced the levels of these metals 90% and had an average reduction of one magnitude. The paired t-tests that were performed for each metal demonstrated that there was a statistically significant reduction of the metal after the use of the coating: lead (p = 0.03), beryllium (p = 0.05), aluminum (p = 0.006), iron (p = 0.0001), and copper (p = 0.004). The Kendall tau-b correlation coefficient demonstrates that there was a positive correlation between the initial levels of contamination and the removal efficiency for all the samples taken from different locations on the floor for each of the three sites. This new decontamination technique worked efficiently, requiring only one application, which decreased exposure time and did not generate any airborne dust. PMID:19437305
Prior to re-entering a building following a chemical attack, decontamination and testing must be conducted to determine whether toxic agents have been eliminated or reduced to safe levels. Building contents must also be decontaminated and tested or destroyed. Recent incidents i...
Braue, Ernest H; Smith, Kelly H; Doxzon, Bryce F; Lumpkin, Horace L; Clarkson, Edward D
2011-03-01
This report, the second in a series of five, directly compares the efficacy of Reactive Skin Decontamination Lotion (RSDL), the M291 Skin Decontamination Kit (SDK), 0.5% bleach (sodium or calcium hypochlorite solution), 1% soapy water, and Skin Exposure Reduction Paste Against Chemical Warfare Agents (SERPACWA) in the haired guinea pig model following exposure to soman (GD). In all experiments, guinea pigs were close-clipped and given anesthesia. In the decontamination experiments, the animals were challenged with GD and decontaminated after a 2-minute delay for the standard procedure or at longer times for the delayed-decontamination experiments. Positive control animals were challenged with GD in the same manner as the treated animals, except that they received no treatment. All animals were observed during the first 4 hours and again at 24 hours after exposure for signs of toxicity and death. The protective ratio (PR, defined as the median lethal dose [LD(50)] of the treatment group divided by the LD(50) of the untreated positive control animals) was calculated from the derived probit dose-response curves established for each treatment group and nontreated control animals. SERPACWA was applied as a thin coating (0.1 mm thick), allowed to dry for 15 minutes, and challenged with GD. After a 2-hour challenge, any remaining GD was blotted off the animal, but no additional decontamination was done. Significance in this report is defined as p <.05. Neat (undiluted) GD was used to challenge all animals in these studies. In the standard 2-minute GD decontamination experiments, the calculated PRs for RSDL, 0.5% bleach, 1% soapy water, and M291 SDK were 14, 2.7, 2.2, and 2.6, respectively. RSDL was by far the most effective decontamination product tested and significantly better than any of the other products. Bleach, soapy water, and the M291 SDK provided equivalent and modest protection. Since only RSDL provided at least good protection (PR > 5), it was the only decontamination product evaluated for delayed decontamination. In the GD delayed-decontamination experiments, the calculated LT(50) (the delayed-decontamination time at which 50% of the animals die in the test population following a 5-LD(50) challenge) value for RSDL was only 4.0 minutes. Several conclusions can be drawn from this study: 1) Reactive Skin Decontamination Lotion provided superior protection against GD compared with the other products tested; 2) The 0.5% bleach solution, the 1% soapy water solution, and the M291 SDK were less effective than RSDL, but still provided modest (2 < PR < 5) protection against GD; 3) Reactive Skin Decontamination Lotion, the best product tested, did not provide significant protection against GD when decontamination was delayed for more than 3 minutes; 4) Skin Exposure Reduction Paste Against Chemical Warfare Agents provided significant, but modest, protection against GD; 5) There was good correlation between using the rabbit model and the guinea pig model for decontamination efficacy evaluations; and 6) Soman (GD) is an agent of real concern because it is very difficult to decontaminate and the effects of exposure are difficult to treat.
Erdoğdu, S Belgin; Ekiz, H İbrahim
2011-01-01
Cumin seeds might be exposed to a high level of natural bacterial contamination, and this could potentially create a public health risk besides leading to problems in exportation. Ultraviolet (UVC) and far infrared (FIR) radiation has low penetration power, and due to that, there might be no detrimental defects to the products during a possible decontamination process. Therefore, the objective of this study was to determine the effect of UVC and FIR treatment on microbial decontamination and quality of cumin seeds. For this purpose, FIR treatment at different exposure times and temperatures were applied followed by constant UVC treatment with an intensity of 10.5 mW/cm² for 2 h. Total mesophilic aerobic bacteria of the cumin seeds were decreased to the target level of 10⁴ CFU/g after 1.57, 2.8, and 4.8 min FIR treatment at 300, 250, and 200 °C, respectively, following a 2 h UVC treatment. Under the given conditions, a complete elimination for total yeast and molds were obtained while there were no significant changes in volatile oil content and color of the cumin seeds. Consequently, combined UVC and FIR treatment was determined to be a promising method for decontamination of the cumin seeds. This research attempts to apply UVC and far infrared (FIR) radiation for pasteurization of cumin seeds. The data suggested that combined UVC and FIR radiation treatments can become a promising new method for pasteurization of cumin seeds without causing any detrimental defect to the quality parameters. The results of this industry partnered (Kadioglu Baharat, Mersin, Turkey--http://www.kadioglubaharat.com) study were already applied in industrial scale production lines. © 2011 Institute of Food Technologists®
Wada, Koji; Yoshikawa, Toru; Murata, Masaru
2012-01-01
This article describes occupational health measures for workers involved in decontamination of radioactive material discharged around Fukushima Dai-ichi Nuclear Power Plant after the explosions in 2011. Decontamination is performed by removing radioactive particles (mainly cesium) from surfaces of soil, grass and trees, and buildings. Measurement of radiation doses is necessary to reduce exposure, and to determine whether workers can work below dose limits. Protective equipment for decontamination is determined based on the concentration of radiation in contaminated soil and the exposure to dust. Health examinations by physicians are mandated for decontamination workers upon hiring and every 6 months. While there is no possibility of acute radiation injury from decontamination, workers may be anxious about the unclear effects of chronic low level radiation exposure on health. Measures to protect the decontamination workers are the top priority.
Skin decontamination efficacy of potassium ketoxime on rabbits exposed to sulfur mustard.
Sun, Jing-Hai; Sun, Pei-Pei; Zheng, Wei; Han, Song; Ying, Ying; Liu, Hong-Yan; Zhang, Cheng; Zhao, Bao-Quan; Zuo, Guo-Min; Lu, Hong; Zhong, Yu-Xu
2015-03-01
The chemical weapon sulfur mustard (SM) is a blister agent, and currently, there is no effective antidote. To evaluate the decontamination efficacy of potassium ketoxime against SM and preliminarily elucidate its decontamination mechanism. Potassium ketoxime reacted with SM, and SM residues were tested at different time intervals by T-135 colorimetry after the reaction. Rabbit skin was topically exposed to 2 mg/cm(2) SM, treated with potassium ketoxime 1 min later, and observed after 6, 12, and 24 h. Gas chromatography-mass spectroscopy was employed to screen and identify the main products of potassium ketoxime decontamination of SM. Potassium ketoxime had a great effect against SM contamination. With a mass ratio of decontaminant: SM of 50:1, decontamination rates against SM were 87.5% after 30 s, 95.9% after 1 min, and 99.0% after 5 min. Fifteen minutes after exposure to SM, the untreated group showed clear erythema lesions, whereas the experimental group showed no clear erythema lesions within 6 h. After 12 and 24 h, the areas of damaged skin in the experimental group were 0.038 and 0.125 cm(2), respectively, compared with 2.21 and 2.65 cm(2) in the control group. Histopathological analysis revealed that treatment with potassium ketoxime also reduced inflammation-induced damage. The results of this study indicate that potassium ketoxime reacted rapidly and completely with SM, and thus, it was found to be a suitable and effective skin decontaminant against SM. The decontamination reaction mechanism is mainly related to nucleophilic substitution.
1997-01-01
of Chemical Decontamination Inventors Philip W. Bartram, Noel C. Dibona , James H. Buchanan and Dennis K. Rohrbaugh Abstract An absorption process of...Decontamination Inventors Philip W. Bartram, Noel C. Dibona , James H. Buchanan and Dennis K. Rohrbaugh Abstract An improved method of decontaminating a...Using a Macro-reticular Strong Acid Resin Inventors Philip W. Bartram, Noel C. Dibona , James H. Buchanan, and Dennis K. Rohrbaugh Abstract A
Granulated decontamination formulations
Tucker, Mark D.
2007-10-02
A decontamination formulation and method of making that neutralizes the adverse health effects of both chemical and biological compounds, especially chemical warfare (CW) and biological warfare (BW) agents, and toxic industrial chemicals. The formulation provides solubilizing compounds that serve to effectively render the chemical and biological compounds, particularly CW and BW compounds, susceptible to attack, and at least one reactive compound that serves to attack (and detoxify or kill) the compound. The formulation includes at least one solubilizing agent, a reactive compound, a sorbent additive, and water. A highly adsorbent sorbent additive (e.g., amorphous silica, sorbitol, mannitol, etc.) is used to "dry out" one or more liquid ingredients into a dry, free-flowing powder that has an extended shelf life, and is more convenient to handle and mix in the field.
Evaluation of standardized sample collection, packaging, and ...
Journal Sample collection procedures and primary receptacle (sample container and bag) decontamination methods should prevent contaminant transfer between contaminated and non-contaminated surfaces and areas during bio-incident operations. Cross-contamination of personnel, equipment, or sample containers may result in the exfiltration of biological agent from the exclusion (hot) zone and have unintended negative consequences on response resources, activities and outcomes. The current study was designed to: (1) evaluate currently recommended sample collection and packaging procedures to identify procedural steps that may increase the likelihood of spore exfiltration or contaminant transfer; (2) evaluate the efficacy of currently recommended primary receptacle decontamination procedures; and (3) evaluate the efficacy of outer packaging decontamination methods. Wet- and dry-deposited fluorescent tracer powder was used in contaminant transfer tests to qualitatively evaluate the currently-recommended sample collection procedures. Bacillus atrophaeus spores, a surrogate for Bacillus anthracis, were used to evaluate the efficacy of spray- and wipe-based decontamination procedures.
1988-12-30
LIMITING ACTIVATED ZOLUTION OF HYPOCHLORITE), SADS (SURFACE ACTIVE DISPLACEMENT SYSTEMS ), SACRIFICIAL COAT!ý:GS, MICRO EMULSIONS , DS2, STB SLURRY...CURRENT SYSTEMS AND THOSE IN DEVELOPMENT WITH NOT MEET ALL DECONTAMINATION NEEDS. ITEMS TO BE FIELDED WILL INCLUDE: AN EMULSION BSED DECONTAMINATION...DECONTAMINATION SYSTEM FOR AIRCRAFT EXTERIORS; MICROEMULSIONS CONTAINING REACTIVE DECONTAMINANTS (FORMULATION, EFFICACY, AND 181 OPTIMIZATION); COOLING OF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joiner, R.L.; Keys, W.B.; Harroff, H.H.
1988-02-18
A task was assigned to Battelle's Medical Research and Evaluation Facility(MREF) to evaluate the effectiveness of two candidate decontamination systems when compared to the standard dual component M258A1 decontamination system currently fielded by the U.S. Army. The chemical surety material (CSM) used in the evaluation were the organophosphates Soman (GD), polymer thickened GD (TGD), and VX, and the vesicants sulfur mustard (HD) and Lewisite (LS). The efficacies of the two candidate decontamination systems were evaluated in such a manner as to determine the LD50 and protective ratio (PR) for each decontaminant against each organophosphate CSM as compared to the standardmore » M258A1 decontamination system LD50. The PR constituted a comparison for each candidate system against the M258A1 standard. In the vesicant phase of the screen, the efficacies of the candidate systems were evaluated in a side-by-side comparison to the M258A1 decontamination system to determine whether the candidates were as good as or better than the standard dual component system.« less
Serrano, Kate A; Martyny, John W; Kofford, Shalece; Contreras, John R; Van Dyke, Mike V
2012-01-01
This study was designed to determine how easily methamphetamine can be removed from clothing and building materials, utilizing different cleaning materials and methods. The study also addressed the penetration of methamphetamine into drywall and the ability of paints to encapsulate the methamphetamine on drywall. Clothing and building materials were contaminated in a stainless steel chamber by aerosolizing methamphetamine in a beaker heater. The amount of methamphetamine surface contamination was determined by sampling a grid pattern on the material prior to attempting to clean the materials. After cleaning, the materials were again sampled, and the degree of decontamination noted. We found that household clothing and response gear worn by first responders was easily decontaminated using a household detergent in a household washing machine. A single wash removed over 95% of the methamphetamine from these materials. The study also indicated that methamphetamine-contaminated, smooth non-porous surfaces can be easily cleaned to below detectable levels using only mild cleaners. More porous surfaces such as plywood and drywall were unlikely to be decontaminated to below regulatory levels even with three washes using a mild cleaner. This may be due to methamphetamine penetration into the paint on these surfaces. Evaluation of methamphetamine contamination on drywall indicated that approximately 40% of the methamphetamine was removed using a wipe, while another 60% remained in the paint layer. Stronger cleaners such as those with active ingredients including sodium hypochlorite or quaternary ammonia and commercial decontamination agents were more effective than mild detergent-based cleaners and may reduce methamphetamine contamination to below regulatory levels. Results from the encapsulation studies indicate that sprayed on oil-based paint will encapsulate methamphetamine on drywall and plywood surfaces up to 4.5 months, while latex paints were less effective.
NASA Astrophysics Data System (ADS)
Varady, Mark; Mantooth, Brent; Pearl, Thomas; Willis, Matthew
2014-03-01
A continuum model of reactive decontamination in absorbing polymeric thin film substrates exposed to the chemical warfare agent O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (known as VX) was developed to assess the performance of various decontaminants. Experiments were performed in conjunction with an inverse analysis method to obtain the necessary model parameters. The experiments involved contaminating a substrate with a fixed VX exposure, applying a decontaminant, followed by a time-resolved, liquid phase extraction of the absorbing substrate to measure the residual contaminant by chromatography. Decontamination model parameters were uniquely determined using the Levenberg-Marquardt nonlinear least squares fitting technique to best fit the experimental time evolution of extracted mass. The model was implemented numerically in both a 2D axisymmetric finite element program and a 1D finite difference code, and it was found that the more computationally efficient 1D implementation was sufficiently accurate. The resulting decontamination model provides an accurate quantification of contaminant concentration profile in the material, which is necessary to assess exposure hazards.
Elias, Shlomi; Saphier, Sigal; Columbus, Ishay; Zafrani, Yossi
2014-01-01
Among the chemical warfare agents, the extremely toxic nerve agent VX (O-ethyl S-2-(diisopropylamino)ethyl methylphosphonothioate) is a target of high importance in the development of decontamination methods, due to its indefinite persistence on common environmental surfaces. Liquid decontaminants are mostly characterized by high corrosivity, usually offer poor coverage, and tend to flow and accumulate in low areas. Therefore, the development of a noncorrosive decontaminant, sufficiently viscous to resist dripping from the contaminated surface, is necessary. In the present paper we studied different polysaccharides-thickened fluoride aqueous solutions as noncorrosive decontaminants for rapid and efficient VX degradation to the nontoxic product EMPA (ethyl methylphosphonic acid). Polysaccharides are environmentally benign, natural, and inexpensive. Other known decontaminants cannot be thickened by polysaccharides, due to the sensitivity of the latter toward basic or oxidizing agents. We found that the efficiency of VX degradation in these viscous solutions in terms of kinetics and product identity is similar to that of KF aqueous solutions. Guar gum (1.5 wt %) with 4 wt % KF was chosen for further evaluation. The benign nature, rheological properties, adhering capabilities to different surfaces, and decontamination from a porous matrix were examined. This formulation showed promising properties for implementation as a spray decontaminant for common and sensitive environmental surfaces.
Buhr, T L; Young, A A; Minter, Z A; Wells, C M; McPherson, D C; Hooban, C L; Johnson, C A; Prokop, E J; Crigler, J R
2012-11-01
To develop test methods and evaluate the survival of Bacillus anthracis ∆Sterne and Bacillus thuringiensis Al Hakam spores after exposure to hot, humid air. Spores (>7 logs) of both strains were dried on six different test materials. Response surface methodology was employed to identify the limits of spore survival at optimal test combinations of temperature (60, 68, 77°C), relative humidity (60, 75, 90%) and time (1, 4, 7 days). No spores survived the harshest test run (77°C, 90% r.h., 7 days), while > 6·5 logs of spores survived the mildest test run (60°C, 60% r.h., 1 day). Spores of both strains inoculated on nylon webbing and polypropylene had greater survival rates at 68°C, 75% r.h., 4 days than spores on other materials. Electron microscopy showed no obvious physical damage to spores using hot, humid air, which contrasted with pH-adjusted bleach decontamination. Test methods were developed to show that hot, humid air effectively inactivates B. anthracis ∆Sterne and B. thuringiensis Al Hakam spores with similar kinetics. Hot, humid air is a potential alternative to conventional chemical decontamination. © 2012 The Authors Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Pathogen Decontamination of Food Crop Soil: A Review.
Gurtler, Joshua B
2017-09-01
The purpose of this review is to delineate means of decontaminating soil. This information might be used to mitigate soil-associated risks of foodborne pathogens. The majority of the research in the published literature involves inactivation of plant pathogens in soil, i.e., those pathogens harmful to fruit and vegetable production and ornamental plants. Very little has been published regarding the inactivation of foodborne human pathogens in crop soil. Nevertheless, because decontamination techniques for plant pathogens might also be useful methods for eliminating foodborne pathogens, this review also includes inactivation of plant pathogens, with appropriate discussion and comparisons, in the hopes that these methods may one day be validated against foodborne pathogens. Some of the major soil decontamination methods that have been investigated and are covered include chemical decontamination (chemigation), solarization, steaming, biofumigation, bacterial competitive exclusion, torch flaming, microwave treatment, and amendment with biochar. Other innovative means of inactivating foodborne pathogens in soils may be discovered and explored in the future, provided that these techniques are economically feasible in terms of chemicals, equipment, and labor. Food microbiology and food safety researchers should reach out to soil scientists and plant pathologists to create links where they do not currently exist and strengthen relationships where they do exist to take advantage of multidisciplinary skills. In time, agricultural output and the demand for fresh produce will increase. With advances in the sensitivity of pathogen testing and epidemiological tracebacks, the need to mitigate preharvest bacterial contamination of fresh produce will become paramount. Hence, soil decontamination technologies may become more economically feasible and practical in light of increasing the microbial safety of fresh produce.
Jacquet, Pauline; Daudé, David; Bzdrenga, Janek; Masson, Patrick; Elias, Mikael; Chabrière, Eric
2016-05-01
Organophosphorus chemicals are highly toxic molecules mainly used as pesticides. Some of them are banned warfare nerve agents. These compounds are covalent inhibitors of acetylcholinesterase, a key enzyme in central and peripheral nervous systems. Numerous approaches, including chemical, physical, and biological decontamination, have been considered for developing decontamination methods against organophosphates (OPs). This work is an overview of both validated and emerging strategies for the protection against OP pollution with special attention to the use of decontaminating enzymes. Considerable efforts have been dedicated during the past decades to the development of efficient OP degrading biocatalysts. Among these, the promising biocatalyst SsoPox isolated from the archaeon Sulfolobus solfataricus is emphasized in the light of recently published results. This hyperthermostable enzyme appears to be particularly attractive for external decontamination purposes with regard to both its catalytic and stability properties.
An improved method for emergent decontamination of ocular and dermal hydrofluoric acid splashes.
Soderberg, Kjell; Kuusinen, Petri; Mathieu, Laurence; Hall, Alan H
2004-08-01
Accidental hydrofluoric acid (HF) splashes often occur in industrial settings. HF easily penetrates into tissues by initial acid action allowing fluoride ions to penetrate deeply, chelating calcium and magnesium. Resultant hypocalcemia and hypomagnesemia can be fatal. This report describes the utilization of Hexafluorine--a hypertonic, amphoteric, chelating decontamination solution--in workplaces where water decontamination followed by calcium gluconate inunction failed to prevent HF burns and systemic toxicity. Between 1998 and 1999, 16 cases of ocular and dermal HF splashes with either 70% HF or 6% HF/15% nitric acid (HNO3) were decontaminated with Hexafluorine at the worksite. HF burns did not develop and medical treatment other than initial decontamination was not reQuired in 12/16 (75%). In 7/16 (44%) cases, lost work time corresponded to duration of hospital observation (mean < 1 d).
Cravotto, Giancarlo; Di Carlo, Stefano; Ondruschka, Bernd; Tumiatti, Vander; Roggero, Carlo Maria
2007-10-01
The effect on halogenated aromatics of solid, non-toxic oxidants such as sodium percarbonate and the urea/hydrogen peroxide complex (Fenton-like reagents) was investigated. A microwaves-assisted, solvent-free method for soil decontamination is presented. It marks a considerable advance in the search of more efficient, environment-friendly procedures for the degradative oxidation of persistent organic pollutants. Residual pollutants in treated soil samples were determined by GC/MS analysis after solvent extraction or direct thermal desorption. Results showed that 4-chloronaphthol, 2,4-dichlorophenoxyacetic acid and p-nonylphenol had been degraded completely, 2,4-dibromophenol to a large extent.
DECONTAMINATION OF STRUCTURES AND DEBRIS AT SUPERFUND SITES
Two building decontamination technologies were demonstrated and evaluated: a method for in situ degradation of PCB's requiring application of an alkali metal/polyethylene glycolate mixture directly on concrete surfaces; and a shotblasting technique using steel shot to cut away co...
NASA Astrophysics Data System (ADS)
Sadeghi, Meysam; Yekta, Sina; Ghaedi, Hamed
2017-04-01
In the current research, MCM-41 was successfully prepared by the sol-gel method and lead ions (Pb2+) were loaded in the synthesized MCM-41 mesoporous structure to prepare Pb-MCM-41. The ZnO-NiO nanoparticles (ZnNiO2 NPs) as a type of bimetallic oxides were then dispersed and deposited on the surface of Pb-MCM-41 through indirect method to gain the final Pb-MCM-41/ZnNiO2 nanocomposite adsorbent. The characterization study of samples carried out by SEM-EDAX, AFM, XRD and FTIR techniques. Pb-MCM-41/ZnNiO2 nanocomposite as a destructive adsorbent has been proposed for the first time for the decontamination process of chloroethyl phenyl sulfide (CEPS), a mimic of bis(chloroethyl) sulfide (i.e. sulfur mustard), and were confirmed using GC-FID, GC-MS and FTIR instruments. Besides, the effect of different experimental parameters including contact time, catalyst dose and initial concentration of CEPS on the decontamination efficiency of this agent simulant were also perused. The GC-FID analysis results verified that the maximum decontamination of CEPS was more than 90% yield. The parameters such as: contact time (240 min), adsorbent dose (0.4 g/L), and initial concentration (10 mg/L) were investigated and considered as optimized conditions for the noted reaction. Moreover, the reaction kinetic information was surveyed by employing first order model. The values of the rate constant (k) and half-life (t1/2) were determined as 0.0128 min-1 and 54.1406 min, and 0.0012 min-1 and 577.5 min for CEPS and its hydrolysis/elimination products, respectively. Data demonstrates the role of the hydrolysis and elimination products, i.e. hydroxy ethyl phenyl sulfide (HEPS) and phenyl vinyl sulfide (PVS) in the reaction of CEPS with Pb-MCM-41/ZnNiO2 nanocomposite and GC-MS analysis was exerted to identify and quantify simulant destruction products. It was clarified that Pb-MCM-41/ZnNiO2 nanocomposite gains a high capacity and potential for the effective decontamination of CEPS.
Hairy skin exposure to VX in vitro: effectiveness of delayed decontamination.
Rolland, P; Bolzinger, M-A; Cruz, C; Josse, D; Briançon, S
2013-02-01
The chemical warfare agents such as VX represent a threat for both military and civilians, which involves an immediate need of effective decontamination systems. Since human scalp is usually unprotected compared to other body regions covered with clothes, it could be a preferential site of exposure in case of terrorist acts. The purpose of this study was to determine if skin decontamination could be efficient when performed more than 1h after exposure. In addition, the impact of hairs in skin contamination was investigated. By using in vitro skin models, we demonstrated that about 75% of the applied quantity of VX was recovered on the skin surface 2h after skin exposition, which means that it is worth decontaminating even if contamination occurred 2h before. The stratum corneum reservoir for VX was quickly established and persistent. In addition, the presence of hairs modified the percutaneous penetration of the nerve agent by binding of VX to hairs. Hair shaft has thus to be taken into account in the decontamination process. Reactive Skin Decontamination Lotion (RSDL) and Fuller's Earth (FE) were active in the skin decontamination 45min post-exposure, but RSDL was more efficient in reducing the amount of VX either in the skin or in the hair. Copyright © 2012 Elsevier Ltd. All rights reserved.
Decontamination of chemical warfare sulfur mustard agent simulant by ZnO nanoparticles
NASA Astrophysics Data System (ADS)
Sadeghi, Meysam; Yekta, Sina; Ghaedi, Hamed
2016-07-01
In this study, zinc oxide nanoparticles (ZnO NPs) have been surveyed to decontaminate the chloroethyl phenyl sulfide as a sulfur mustard agent simulant. Prior to the reaction, ZnO NPs were successfully prepared through sol-gel method in the absence and presence of polyvinyl alcohol (PVA). PVA was utilized as a capping agent to control the agglomeration of the nanoparticles. The formation, morphology, elemental component, and crystalline size of nanoscale ZnO were certified and characterized by SEM/EDX, XRD, and FT-IR techniques. The decontamination (adsorption and destruction) was tracked by the GC-FID analysis, in which the effects of polarity of the media, such as isopropanol, acetone and n-hexane, reaction time intervals from 1 up to 18 h, and different temperatures, including 25, 35, 45, and 55 °C, on the catalytic/decontaminative capability of the surface of ZnO NPs/PVA were investigated and discussed, respectively. Results demonstrated that maximum decontamination (100 %) occurred in n-hexane solvent at 55 °C after 1 h. On the other hand, the obtained results for the acetone and isopropanol solvents were lower than expected. GC-MS chromatograms confirmed the formation of hydroxyl ethyl phenyl sulfide and phenyl vinyl sulfide as the destruction reaction products. Furthermore, these chromatograms proved the role of hydrolysis and elimination mechanisms on the catalyst considering its surface Bronsted and Lewis acid sites. A non-polar solvent aids material transfer to the reactive surface acid sites without blocking these sites.
Cahill, Orla J; Claro, Tânia; Cafolla, Attilio A; Stevens, Niall T; Daniels, Stephen; Humphreys, Hilary
2017-10-01
OBJECTIVE To evaluate the efficacy of a multijet cold-plasma system and its efficacy in decontaminating 2 surfaces commonly found in hospitals DESIGN An in vitro study of common causes of healthcare-acquired infection METHODS Log10 9 cultures of methicillin-resistant Staphylococcus aureus, vancomycin-resistant enterococci, extended spectrum β-lactamase-producing Escherichia coli, and Acinetobacter baumannii were applied to 5-cm2 sections of stainless steel and mattress. Human serum albumin (HSA) was used as a proxy marker for organic material, and atomic force microscopy (AFM) was used to study the impact on bacterial cell structure. The inoculated surfaces were exposed to a cold-air-plasma-generating multijet prototype for 15, 20, 30, and 45 seconds. RESULTS After 45 seconds, at least 3 to 4 log reductions were achieved for all bacteria on the mattress, while 3 to 6 log reductions were observed on stainless steel. The presence of HSA had no appreciable effect on bacterial eradication. The surfaces with bacteria exposed to AFM showed significant morphological changes indicative of "etching" due to the action of highly charged ions produced by the plasma. CONCLUSION This multijet cold-plasma prototype has the potential to augment current environmental decontamination approaches but needs further evaluation in a clinical setting to confirm its effectiveness. Infect Control Hosp Epidemiol 2017;38:1182-1187.
Oxidative Tritium Decontamination System
Gentile, Charles A. , Guttadora, Gregory L. , Parker, John J.
2006-02-07
The Oxidative Tritium Decontamination System, OTDS, provides a method and apparatus for reduction of tritium surface contamination on various items. The OTDS employs ozone gas as oxidizing agent to convert elemental tritium to tritium oxide. Tritium oxide vapor and excess ozone gas is purged from the OTDS, for discharge to atmosphere or transport to further process. An effluent stream is subjected to a catalytic process for the decomposition of excess ozone to diatomic oxygen. One of two configurations of the OTDS is employed: dynamic apparatus equipped with agitation mechanism and large volumetric capacity for decontamination of light items, or static apparatus equipped with pressurization and evacuation capability for decontamination of heavier, delicate, and/or valuable items.
Alcock, Joseph P; Barbour, Michele E; Sandy, Jonathan R; Ireland, Anthony J
2009-08-01
The purpose of this research was to investigate the effects of decontamination and clinical exposure on the elastic moduli, hardness and surface roughness of two frequently used orthodontic archwires, namely 0.020in.x0.020in. heat activated (martensitic active) nickel titanium archwires and 0.019in.x0.025in. austenitic stainless steel archwires. This study was a prospective clinical trial in which 20 consecutive patients requiring an archwire change as part of their course of orthodontic fixed appliance therapy, had either a nickel titanium or stainless steel archwire fitted as deemed clinically necessary. The effect of clinical use was determined by comparing distal end cuts of the "as received" archwires before and after decontamination, with the same retrieved archwires following clinical use and decontamination. Hardness, elastic modulus and surface roughness were determined using an atomic force microscope (AFM) coupled with a nanoindenter. The results showed that the decontamination regimen and clinical use had no statistically significant effect on the nickel titanium archwires, but did have a statistically significant effect on the steel archwires. Decontamination of the steel wires significantly increased the observed surface hardness (p=0.01) and reduced the surface roughness (p=0.02). Clinical use demonstrated a statistically significant increase in the observed elastic modulus (p<0.001) and a decrease in surface roughness (p=0.001). At present it is difficult to predict the clinical significance of these statistically significant changes in archwire properties on orthodontic tooth movement.
Barraoui, Driss; Labrecque, Michel; Blais, Jean-François
2008-03-01
Given the fact that, according to our knowledge, no study has compared the agro-environmental use of decontaminated with non-decontaminated sludge, a greenhouse experiment was carried out to test the growth of maize (Zea mays L., G-4011 Hybrid) and bioaccumulation of metals in the presence of four different sludges (MUC, QUC, BEC and DAI), before and after their decontamination by a novel process (METIX-AC). Data showed that decontaminated sludge ameliorated plant growth and biomass production, and decreased bioaccumulation of metals, more than control soil, inorganic chemical fertilization, or conventional non-decontaminated sludge. Since chemicals used by the METIX-AC process contained S and Fe, decontaminated sludge introduced large amounts of these elements, while the overall presence of metals was reduced. Often, sludge dose also affected maize growth and bioaccumulation of metals. Overall, no toxicity to plants was noticed and bioaccumulation and transfer of many metals remained below the limits reported in the literature.
McKernan, Kevin J.; Spangler, Jessica; Zhang, Lei; Tadigotla, Vasisht; McLaughlin, Stephen; Warner, Jason; Zare, Amir; Boles, Richard G.
2014-01-01
We have developed a PCR method, coined Déjà vu PCR, that utilizes six nucleotides in PCR with two methyl specific restriction enzymes that respectively digest these additional nucleotides. Use of this enzyme-and-nucleotide combination enables what we term a “DNA diode”, where DNA can advance in a laboratory in only one direction and cannot feedback into upstream assays. Here we describe aspects of this method that enable consecutive amplification with the introduction of a 5th and 6th base while simultaneously providing methylation dependent mitochondrial DNA enrichment. These additional nucleotides enable a novel DNA decontamination technique that generates ephemeral and easy to decontaminate DNA. PMID:24788618
CATALYTIC ENZYME-BASED METHODS FOR WATER TREATMENT AND WATER DISTRIBUTION SYSTEM DECONTAMINATION
Current chemistry-based decontaminants for chemical or biological warfare agents and related toxic materials are caustic and have the potential for causing material and environmental damage. In addition, most are bulk liquids that require significant logistics and storage capabil...
De Geyter, Deborah; Cnudde, Danny; Van der Beken, Mieke; Autaers, Dorien; Piérard, Denis
2018-04-01
The purpose of this study was to test a newly developed decontamination and fluidization kit for processing respiratory specimens for the detection of mycobacteria: the Myco-TB procedure (developed by Copan (Brescia, Italy)). This technique was compared with the Zephiran decontamination method in use in our hospital. Respiratory specimens (n = 387: 130 endotracheal/bronchial aspirates, 172 bronchoalveolar lavages and 55 sputa) submitted to the University Hospital of Brussels between January 2016 and March 2017 were included. All samples were divided into two aliquots: one was subjected to the Myco-TB method and one to the Zephiran technique prior to culture. The sensitivities for culture for the Zephiran technique on solid media, the Myco-TB method on solid media and Myco-TB combined with the MGIT™ system were respectively 67%, 87% and 89%. The contamination rates were 22% with both the Zephiran and Myco-TB method on solid media and only 4% with the Myco-TB kit combined with the MGIT™ system. For direct microscopy, the sensitivities of the Zephiran method and the Myco-TB method were equal (40%) when the centrifugation time was 20 min. The Myco-TB decontamination method is easy and rapid to perform. It is more sensitive for culture as compared to the Zephiran method and gives lower contamination levels when combined with the MGIT™ technique. When increasing the centrifugation step to 20 min, the sensitivity of direct microscopy is equal to the Zephiran method.
Leonardi, Natalia M; Tesán, Fiorella C; Zubillaga, Marcela B; Salgueiro, María J
2014-12-01
In accord with as-low-as-reasonably-achievable and good-manufacturing-practice concepts, the present study evaluated the efficiency of radioactivity decontamination of materials commonly used in laboratory surfaces and whether solvent spills on these materials affect the findings. Four materials were evaluated: stainless steel, a surface comprising one-third acrylic resin and two-thirds natural minerals, an epoxy cover, and vinyl-based multipurpose flooring. Radioactive material was eluted from a (99)Mo/(99m)Tc generator, and samples of the surfaces were control-contaminated with 37 MBq (100 μL) of this eluate. The same procedure was repeated with samples of surfaces previously treated with 4 solvents: methanol, methyl ethyl ketone, acetone, and ethanol. The wet radioactive contamination was allowed to dry and then was removed with cotton swabs soaked in soapy water. The effectiveness of decontamination was defined as the percentage of activity removed per cotton swab, and the efficacy of decontamination was defined as the total percentage of activity removed, which was obtained by summing the percentages of activity in all the swabs required to complete the decontamination. Decontamination using our protocol was most effective and most efficacious for stainless steel and multipurpose flooring. Moreover, treatment with common organic solvents seemed not to affect the decontamination of these surfaces. Decontamination of the other two materials was less efficient and was interfered with by the organic solvents; there was also great variability in the overall results obtained for these other two materials. In expanding our laboratory, it is possible for us to select those surface materials on which our decontamination protocol works best. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.
A Field-Based Cleaning Protocol for Sampling Devices Used in Life-Detection Studies
NASA Astrophysics Data System (ADS)
Eigenbrode, Jennifer; Benning, Liane G.; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E. F.
2009-06-01
Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.
A field-based cleaning protocol for sampling devices used in life-detection studies.
Eigenbrode, Jennifer; Benning, Liane G; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E F
2009-06-01
Analytical approaches to extant and extinct life detection involve molecular detection often at trace levels. Thus, removal of biological materials and other organic molecules from the surfaces of devices used for sampling is essential for ascertaining meaningful results. Organic decontamination to levels consistent with null values on life-detection instruments is particularly challenging at remote field locations where Mars analog field investigations are carried out. Here, we present a seven-step, multi-reagent decontamination method that can be applied to sampling devices while in the field. In situ lipopolysaccharide detection via low-level endotoxin assays and molecular detection via gas chromatography-mass spectrometry were used to test the effectiveness of the decontamination protocol for sampling of glacial ice with a coring device and for sampling of sediments with a rover scoop during deployment at Arctic Mars-analog sites in Svalbard, Norway. Our results indicate that the protocols and detection technique sufficiently remove and detect low levels of molecular constituents necessary for life-detection tests.
ICU-acquired candidemia within selective digestive decontamination studies: a meta-analysis.
Hurley, James C
2015-11-01
To estimate the direct and indirect (contextual) effects of the factorized constituents of selective digestive decontamination and selective oropharyngeal decontamination (SDD/SOD), being topical antibiotic (TA) and protocolized antifungal prophylaxis (PAFP), on ICU-acquired candidemia. A broad range of ICU candidemia incidence studies were sourced to serve as points of reference. The candidemia incidence was extracted from component (control and intervention) groups decanted from studies of various designs (concurrent or non-concurrent) and whether investigating SDD/SOD versus non-TA methods of ICU infection prevention. The candidemia incidences were summarized in regression models using generalized estimating equation (GEE) methods. Groups derived from observational studies (no prevention method under study) provided an overarching external benchmark candidemia incidence for calibration. Within studies investigating SDD/SOD, the mean (and 95% confidence interval) candidemia incidence among concurrent component groups (40 control; 2.4%; 1.7-3.2% and 43 intervention groups; 2.4%; 1.6-3.1%), but not non-concurrent control groups (11 groups; 1.6%; 0.1-2.7%), is higher than that of the benchmark candidemia incidence derived from 54 observational groups (1.5%; 1.2-1.9%). The TA constituent within SDD/SOD has significant direct and indirect (contextual) effects in GEE models even after adjusting for the publication year and the group-wide presence of either candidemia risk factors or PAFP use. The TA constituent of SDD/SOD is associated with a contextual effect on candidemia incidence which is similar in magnitude to that of the conventional candidemia risk factors and against which PAFP partially attenuates. This increase is inapparent within individual SDD/SOD studies examined in isolation.
Decontamination of metals using chemical etching
Lerch, Ronald E.; Partridge, Jerry A.
1980-01-01
The invention relates to chemical etching process for reclaiming contaminated equipment wherein a reduction-oxidation system is included in a solution of nitric acid to contact the metal to be decontaminated and effect reduction of the reduction-oxidation system, and includes disposing a pair of electrodes in the reduced solution to permit passage of an electrical current between said electrodes and effect oxidation of the reduction-oxidation system to thereby regenerate the solution and provide decontaminated equipment that is essentially radioactive contamination-free.
Method for electrochemical decontamination of radioactive metal
Ekechukwu, Amy A [Augusta, GA
2008-06-10
A decontamination method for stripping radionuclides from the surface of stainless steel or aluminum material comprising the steps of contacting the metal with a moderately acidic carbonate/bicarbonate electrolyte solution containing sodium or potassium ions and thereafter electrolytically removing the radionuclides from the surface of the metal whereby radionuclides are caused to be stripped off of the material without corrosion or etching of the material surface.
NASA Astrophysics Data System (ADS)
Shtripling, L. O.; Kholkin, E. G.
2018-01-01
The article presents the procedure for determining the basic geometrical setting parameters for the oil-contaminated soils decontamination with reagent encapsulation method. An installation is considered for the operational elimination of the emergency consequences accompanied with oil spills, and the installation is adapted to winter conditions. In the installations exothermic process thermal energy of chemical neutralization of oil-contaminated soils released during the decontamination is used to thaw frozen subsequent portions of oil-contaminated soil. Installation for oil-contaminated soil decontamination as compared with other units has an important advantage, and it is, if necessary (e.g., in winter) in using the heat energy released at each decontamination process stage of oil-contaminated soil, in normal conditions the heat is dispersed into the environment. In addition, the short-term forced carbon dioxide delivery at the decontamination process final stage to a high concentration directly into the installation allows replacing the long process of microcapsule shells formation and hardening that occur in natural conditions in the open air.
Study on hot melt pressure sensitive coil material for removing surface nuclear pollution dust
NASA Astrophysics Data System (ADS)
Wang, Jing; Li, Jiao; Wang, Jianhui; Zheng, Li; Li, Jian; Lv, Linmei
2018-02-01
A new method for removing surface nuclear pollution by using hot melt pressure sensitive membrane was presented. The hot melt pressure sensitive membrane was designed and prepared by screening hot melt pressure sensitive adhesive and substrate. The simulated decontamination test of the hot melt pressure sensitive membrane was performed by using 100 mesh and 20 mesh standard sieve dust for simulation of nuclear explosion fall ash and radioactive contaminated particles, respectively. It was found that the single decontamination rate of simulated fall ash and contaminated particles were both above 80% under pressure conditions of 25kPa or more at 140°C. And the maximum single decontamination rate was 92.5%. The influence of heating temperature and pressure on the decontamination rate of the membrane was investigated at the same time. The results showed that higher heating temperature could increase the decontamination rate by increasing the viscosity of the adhesive. When the adhesive amount of the adhesive layer reached saturation, a higher pressure could increase the single decontamination rate also.
Method for regenerating magnetic polyamine-epichlorohydrin resin
Kochen, Robert L.; Navratil, James D.
1997-07-29
Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately.
Method for regenerating magnetic polyamine-epichlorohydrin resin
Kochen, R.L.; Navratil, J.D.
1997-07-29
Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately. 9 figs.
Ayabe, Yoshiko; Hijii, Naoki; Takenaka, Chisato
2017-09-01
We investigated whether local-scale decontamination (removal of the litter layer, superficial soil layer, and understory) in a secondary forest contaminated by the Fukushima nuclear power plant accident reduced 137 Cs contamination of the soil and litter. We also measured 137 Cs concentrations in plants and in the web-building spider Nephila clavata (Nephilidae: Arachnida), as an indicator species, to examine 137 Cs contamination in arthropods. One month after decontamination, the total 137 Cs contamination (soil + litter) was reduced by 20% (100 kBq·m -2 ) relative to that in an adjacent untreated (i.e., contaminated) area, which was however not statistically significant. Four months after decontamination, 137 Cs in the decontaminated area had increased to a level similar to those in the untreated area, and the air radiation dose in the decontaminated area was about 2.1 μSv·h -1 , significantly higher than that in the untreated area (1.9 μSv·h -1 ). This may have been attributed to a torrential rain event. Although no statistically significant reduction was observed, most spiders had a lower 137 Cs contamination than that before the decontamination. This implied that the decontamination may have reduced 137 Cs transfer from soil via litter to N. clavata through the detrital food chains, but may not have reduced the amount of 137 Cs transfer through grazing food chains because the concentration of 137 Cs in living tree leaves was not reduced by the decontamination. In autumn, about 2 kBq·m -2 of 137 Cs was supplied from foliage to the ground by litterfall. The results suggested that removal of the litter and superficial soil layers in a contaminated forest may be ineffective. The present study suggests that the local-scale decontamination in a secondary forest had no effect on the reduction of 137 Cs contamination in the treated area. Copyright © 2017 Elsevier Ltd. All rights reserved.
In-situ generation of chlorine dioxide for surface decontamination of produce
USDA-ARS?s Scientific Manuscript database
Fruits and vegetables, particularly fresh-cut products, are frequently contaminated with bacterial pathogens and implicated in foodborne illnesses. The objective of this study was to develop a unique in-situ sequential surface decontamination method for produce using sodium chlorite and acid. The ...
[In vitro percutaneous absorption of chromium powder and the effect of skin cleanser].
D'Agostin, F; Crosera, M; Adami, G; Malvestio, A; Rosani, R; Bovenzi, M; Maina, G; Filon, F Larese
2007-01-01
Occupational chromium dermatitis occurs frequently among cement and metal workers, workers dealing with leather tanning and employees in the ceramic industry. The present study, using an in-vitro system, evaluated percutaneous absorption of chromium powder and the effect of rapid skin decontamination with a common detergent. Experiments were performed using the Franz diffusion cell method with human skin. Physiological solution was used as receiving phase and a suspension of chromium powder in synthetic sweat was used as donor phase. The tests were performed without or with decontamination using the cleanser 30 minutes after the start of exposure. The amount of chromium permeated through the skin was analysed by Inductively Coupled Plasma Atomic Emission Spectroscopy and Electro Thermal Atomic Absorption Spectroscopy. Speciation analysis and measurements of chromium skin content were also performed. We calculated a permeation flux of 0.843 +/- 0.25 ng cm(-2) h(-1) and a lag time of 1.1 +/- 0.7 h. The cleaning procedure significantly increased chromium skin content, whereas skin passage was not increased. These results showed that chromium powder can pass through the skin and that skin decontamination did not decrease skin absorption. Therefore, it is necessary to prevent skin contamination when using toxic agents.
Leary, Adam D; Schwartz, Michael D; Kirk, Mark A; Ignacio, Joselito S; Wencil, Elaine B; Cibulsky, Susan M
2014-06-01
Decontaminating patients who have been exposed to hazardous chemicals can directly benefit the patients' health by saving lives and reducing the severity of toxicity. While the importance of decontaminating patients to prevent the spread of contamination has long been recognized, its role in improving patient health outcomes has not been as widely appreciated. Acute chemical toxicity may manifest rapidly-often minutes to hours after exposure. Patient decontamination and emergency medical treatment must be initiated as early as possible to terminate further exposure and treat the effects of the dose already absorbed. In a mass exposure chemical incident, responders and receivers are faced with the challenges of determining the type of care that each patient needs (including medical treatment, decontamination, and behavioral health support), providing that care within the effective window of time, and protecting themselves from harm. The US Department of Health and Human Services and Department of Homeland Security have led the development of national planning guidance for mass patient decontamination in a chemical incident to help local communities meet these multiple, time-sensitive health demands. This report summarizes the science on which the guidance is based and the principles that form the core of the updated approach.
Braue, Ernest H; Smith, Kelly H; Doxzon, Bryce F; Lumpkin, Horace L; Clarkson, Edward D
2011-03-01
This report, first in a series of five, directly compares the efficacy of 4 decontamination products and Skin Exposure Reduction Paste Against Chemical Warfare Agents (SERPACWA) in the haired guinea pig model following exposure to VX. In all experiments, guinea pigs were close-clipped and given anesthesia. In the decontamination experiments, the animals were challenged with VX and decontaminated after a 2-minute delay for the standard procedure or at longer times for the delayed-decontamination experiments. Skin Exposure Reduction Paste Against Chemical Warfare Agents was applied as a thin coating (0.1 mm thick), allowed to dry for 15 minutes, and challenged with VX. After a 2-hour challenge, any remaining VX was blotted off the animal, but no additional decontamination was done. Positive control animals were challenged with VX in the same manner as the treated animals, except that they received no treatment. In addition, the positive control animals were always challenged with 5% VX in isopropyl alcohol (IPA) solution, whereas the treatment animals received either neat (undiluted) VX or 5% VX in IPA solution. All animals were observed during the first 4 hours and again at 24 hours after exposure for signs of toxicity and death. The protective ratio (PR, defined as the median lethal dose [LD(50)] of the treatment group divided by the LD(50) of the untreated positive control animals) was calculated from the probit dose-response curves established for each treatment group and nontreated control animals. Significance in this report was defined as p < .05. In the standard 2-minute neat VX decontamination experiments, the calculated PRs for Reactive Skin Decontamination Lotion (RSDL), 0.5% bleach, 1% soapy water, and the M291 Skin Decontamination Kit (SDK) were 66, 17, 16, and 1.1, respectively. Reactive Skin Decontamination Lotion was by far the most effective decontamination product tested and was significantly better than any of the other products. Bleach and soapy water provided equivalent and good (PR > 5) protection. They were both significantly better than the M291 SDK. The M291 SDK did not provide significant protection compared with positive controls. In the neat VX delayed-decontamination experiments, the calculated LT(50) (the delayed-decontamination time at which 50% of the animals died in the test population following a 5-LD(50) challenge) values for RSDL, 0.5% bleach, and 1% soapy water were 31, 48, and 26 minutes, respectively. The results showed that SERPACWA provided significant, but modest (PR < 5), protection against neat VX, with a PR of 2.1. Several conclusions can be drawn from this study: 1) RSDL provided superior protection against VX compared with the other products tested; 2) 0.5% bleach and 1% soapy water were less effective than RSDL, but still provided good protection against VX; 3) the M291 SDK was the least effective decontamination product and did not provide significant protection against VX; 4) the agent was observed to streak when using the M291 SDK, and efficacy may improve if the agent is first blotted, followed by wiping with a new or clean part of the M291 SDK pad; 5) RSDL, 0.5% bleach, and 1% soapy water provided significant protection against a 5-LD(50) challenge of VX, even when decontamination was delayed for up to about 30 minutes; and 6) SERPACWA provided significant, but modest, protection against VX.
Evaluation of Millstone-2 steam generator chemical decontamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Snyder, D.T.; Blok, J.
The steam generator channel heads at Millstone-2 were decontaminated prior to carrying out extensive maintenance work in 1983. Isotopic gamma ray measurements were made of the inner channel head surfaces before and after the decontamination to evaluate the effectiveness of the process. The Combustion Engineering/Kraftwerk Union chemical decontamination, by itself, provided a decontamination factor ranging from 2.7 to 6.6 for the various steam generator surfaces. The corresponding average dose rate reduction factor, based on gross-gamma radiation surveys, was approximately 1.5 to 2.5. Following the chemical treatment, high pressure water flushing reduced the radiation levels still further, to an average overallmore » dose reduction factor of 5.3 to 7.2.« less
Carter, Holly; Amlôt, Richard; Williams, Richard; Rubin, G James; Drury, John
2016-09-15
This short report presents a response to an article written by Cibulsky et al. (2016). The paper by Cibulsky et al. presents a useful and timely overview of the evidence surrounding the technical and operational aspects of mass casualty decontamination. It identifies three priority targets for future research, the third of which is how casualties' needs can be met in ways that best support compliance with and effectiveness of casualty decontamination. While further investigation into behavioural, communication and privacy issues during mass decontamination is warranted, there is now a substantial body of research in this area which is not considered in detail in the succinct summary provided by Cibulsky et al. (2016). In this short report, we summarise the available evidence around likely public behaviour during mass decontamination, effective communication strategies, and potential issues resulting from a lack of privacy. Our intention is to help further focus the research needs in this area and highlight topics on which more research is needed.
Carter, Holly; Amlôt, Richard; Williams, Richard; Rubin, G. James; Drury, John
2016-01-01
This short report presents a response to an article written by Cibulsky et al. (2016). The paper by Cibulsky et al. presents a useful and timely overview of the evidence surrounding the technical and operational aspects of mass casualty decontamination. It identifies three priority targets for future research, the third of which is how casualties' needs can be met in ways that best support compliance with and effectiveness of casualty decontamination. While further investigation into behavioural, communication and privacy issues during mass decontamination is warranted, there is now a substantial body of research in this area which is not considered in detail in the succinct summary provided by Cibulsky et al. (2016). In this short report, we summarise the available evidence around likely public behaviour during mass decontamination, effective communication strategies, and potential issues resulting from a lack of privacy. Our intention is to help further focus the research needs in this area and highlight topics on which more research is needed. PMID:27790381
2014-01-01
SUMMARY There is increasing interest in the role of cleaning for managing hospital-acquired infections (HAI). Pathogens such as vancomycin-resistant enterococci (VRE), methicillin-resistant Staphylococcus aureus (MRSA), multiresistant Gram-negative bacilli, norovirus, and Clostridium difficile persist in the health care environment for days. Both detergent- and disinfectant-based cleaning can help control these pathogens, although difficulties with measuring cleanliness have compromised the quality of published evidence. Traditional cleaning methods are notoriously inefficient for decontamination, and new approaches have been proposed, including disinfectants, steam, automated dispersal systems, and antimicrobial surfaces. These methods are difficult to evaluate for cost-effectiveness because environmental data are not usually modeled against patient outcome. Recent studies have reported the value of physically removing soil using detergent, compared with more expensive (and toxic) disinfectants. Simple cleaning methods should be evaluated against nonmanual disinfection using standardized sampling and surveillance. Given worldwide concern over escalating antimicrobial resistance, it is clear that more studies on health care decontamination are required. Cleaning schedules should be adapted to reflect clinical risk, location, type of site, and hand touch frequency and should be evaluated for cost versus benefit for both routine and outbreak situations. Forthcoming evidence on the role of antimicrobial surfaces could supplement infection prevention strategies for health care environments, including those targeting multidrug-resistant pathogens. PMID:25278571
Dancer, Stephanie J
2014-10-01
There is increasing interest in the role of cleaning for managing hospital-acquired infections (HAI). Pathogens such as vancomycin-resistant enterococci (VRE), methicillin-resistant Staphylococcus aureus (MRSA), multiresistant Gram-negative bacilli, norovirus, and Clostridium difficile persist in the health care environment for days. Both detergent- and disinfectant-based cleaning can help control these pathogens, although difficulties with measuring cleanliness have compromised the quality of published evidence. Traditional cleaning methods are notoriously inefficient for decontamination, and new approaches have been proposed, including disinfectants, steam, automated dispersal systems, and antimicrobial surfaces. These methods are difficult to evaluate for cost-effectiveness because environmental data are not usually modeled against patient outcome. Recent studies have reported the value of physically removing soil using detergent, compared with more expensive (and toxic) disinfectants. Simple cleaning methods should be evaluated against nonmanual disinfection using standardized sampling and surveillance. Given worldwide concern over escalating antimicrobial resistance, it is clear that more studies on health care decontamination are required. Cleaning schedules should be adapted to reflect clinical risk, location, type of site, and hand touch frequency and should be evaluated for cost versus benefit for both routine and outbreak situations. Forthcoming evidence on the role of antimicrobial surfaces could supplement infection prevention strategies for health care environments, including those targeting multidrug-resistant pathogens. Copyright © 2014, American Society for Microbiology. All Rights Reserved.
USDA-ARS?s Scientific Manuscript database
Gamma irradiation is highly effective in inactivating microorganisms in various foods and offers a safe alternative method of food decontamination. In the present study, soybeans (Glycine max L. Merrill) were treated with 0, 1.0, 3.0, 5.0 and 10.0 KGy of gamma irradiation. Microbial populations on s...
Method for the decontamination of metallic surfaces
Purohit, Ankur; Kaminski, Michael D.; Nunez, Luis
2003-01-01
A method of decontaminating a radioactively contaminated oxide on a surface. The radioactively contaminated oxide is contacted with a diphosphonic acid solution for a time sufficient to dissolve the oxide and subsequently produce a precipitate containing most of the radioactive values. Thereafter, the diphosphonic solution is separated from the precipitate. HEDPA is the preferred diphosphonic acid and oxidizing and reducing agents are used to initiate precipitation. SFS is the preferred reducing agent.
Encapsulation method for maintaining biodecontamination activity
Rogers, Robert D.; Hamilton, Melinda A.; Nelson, Lee O.; Benson, Jennifer; Green, Martin J.; Milner, Timothy N.
2002-01-01
A method for maintaining the viability and subsequent activity of microorganisms utilized in a variety of environments to promote biodecontamination of surfaces. One application involves the decontamination of concrete surfaces. Encapsulation of microbial influenced degradation (MID) microorganisms has shown that MID activity is effectively maintained under passive conditions, that is, without manual addition of moisture or nutrients, for an extended period of time.
Encapsulation method for maintaining biodecontamination activity
Rogers, Robert D.; Hamilton, Melinda A.; Nelson, Lee O.; Benson, Jennifer; Green, Martin J.; Milner, Timothy N.
2006-04-11
A method for maintaining the viability and subsequent activity of microorganisms utilized in a variety of environments to promote biodecontamination of surfaces. One application involves the decontamination of concrete surfaces. Encapsulation of microbial influenced degradation (MID) microorganisms has shown that MID activity is effectively maintained under passive conditions, that is, without manual addition of moisture or nutrients, for an extended period of time.
Waste Isolation Pilot Plant Salt Decontamination Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demmer, Ricky Lynn; Reese, Stephen Joseph
2015-03-01
On February 14, 2014, americium and plutonium contamination was released in the Waste Isolation Pilot Plant (WIPP) salt caverns. Several practical, easily deployable methods of decontaminating WIPP salt, using a surrogate contaminant and americium (241Am), were developed and tested. The effectiveness of the methods is evaluated qualitatively, and to the extent practical, quantitatively. Of the methods tested (dry brushing, vacuum cleaning, water washing, mechanical grinding, strippable coatings, and fixative barriers), the most practical seems to be water washing. Effectiveness is very high, and water washing is easy and rapid to deploy. The amount of wastewater produced (~2 L/m2) would bemore » substantial and may not be easy to manage, but the method is the clear winner from a usability perspective. Removable surface contamination levels (smear results) from water washed coupons found no residual removable contamination. Thus, whatever contamination is left is likely adhered to (or trapped within) the salt. The other option that shows promise is the use of a fixative barrier. Bartlett Nuclear, Inc.’s Polymeric Barrier System proved the most durable of the coatings tested. The coatings were not tested for contaminant entrapment, only for coating integrity and durability.« less
Misik, Jan; Jost, Petr; Pavlikova, Ruzena; Vodakova, Eva; Cabal, Jiri; Kuca, Kamil
2013-06-01
The genotoxic vesicant sulphur mustard [bis-2-(chloroethyl)sulphide] is a chemical warfare agent which is easily available due to its relatively simple synthesis. Thus, sulphur mustard is a potential agent for mass contamination. In this study, we focused on sulphur mustard toxicity and decontamination in a rat model using commercially available detergent mixtures for dermal decontamination. Male Wistar rats were percutaneously treated with sulphur mustard and subjected to wet decontamination 2 min postexposure. Commercially produced detergents Neodekont™, Argos™, Dermogel™ and FloraFree™ were tested for their decontamination efficacy against an exposed group and their protective ratios determined. The results showed that all tested detergent solutions produced an increase in the median lethal dose [LD(50) = 9.83 (5.87-13.63) mg·kg(-1)] in comparison to controls, which led to increased survival of experimental animals. In general, all tested detergents provided modest decontamination efficacy (PR = 2.0-5.7). The highest protective ratio (5.7) was consistently achieved with Argos™. Accordingly, Argos™ should be considered in further investigation of mass casualty decontamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oji, L.; Martin, K.; Hobbs, D.
2012-01-03
Experimental results for the selective removal of strontium and cesium from simulated waste solutions with monosodium titanate and crystalline silicotitanate laden filter cartridges are presented. In these proof-of-principle tests, effective uptake of both strontium-85 and cesium-137 were observed using ion-exchangers in this filter cartridge configuration. At low salt simulant conditions, the instantaneous decontamination factor for strontium-85 with monosodium titanate impregnated filter membrane cartridges measured 26, representing 96% strontium-85 removal efficiency. On the other hand, the strontium-85 instantaneous decontamination factor with co-sintered active monosodium titanate cartridges measured 40 or 98% Sr-85 removal efficiency. Strontium-85 removal with the monosodium titanate impregnated membranemore » cartridges and crystalline silicotitanate impregnated membrane cartridges, placed in series arrangement, produced an instantaneous decontamination factor of 41 compared to an instantaneous decontamination factor of 368 for strontium-85 with co-sintered active monosodium titanate cartridges and co-sintered active crystalline silicotitanate cartridges placed in series. Overall, polyethylene co-sintered active titanates cartridges performed as well as titanate impregnated filter membrane cartridges in the uptake of strontium. At low ionic strength conditions, there was a significant uptake of cesium-137 with co-sintered crystalline silicotitanate cartridges. Tests results with crystalline silicotitanate impregnated membrane cartridges for cesium-137 decontamination are currently being re-evaluated. Based on these preliminary findings we conclude that incorporating monosodium titanate and crystalline silicotitanate sorbents into membranes represent a promising method for the semicontinuous removal of radioisotopes of strontium and cesium from nuclear waste solutions.« less
Bion, Julian
2013-12-19
Barriers to the use of selective digestive decontamination include concerns about emergence of resistant organisms, over-estimation of current performance in preventing ventilator-associated pneumonia (VAP), alternative methods of preventing VAP, and misunderstanding of mechanisms of action. A definitive cluster-randomised trial should be undertaken that incorporates practitioner concerns and effect-size preferences.
[Thermodynamic forecasting of reagents composition for soils decontamination].
Nikolaev, V P; Nikolaevskiĭ, V B; Chirkina, I V; Shcheglov, M Iu
2009-01-01
Based on thermodynamic studies, the authors conducted laboratory experiments on searching optimal composition of leaching reagents solution for soils decontamination, when contaminated with Cs-137, of activity coefficient for caesium sulfate microquantities in macrocomponents solutions. The method could be used for modelling the radionuclides phase equillibrium and relocations in soils.
Aims: To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using hydrogen peroxide gas. Methods and Results: B. anthracis, B. subtilis, and G. Stearothermophilus spores were dried on seven...
2010-04-01
PAB 17 2.5.2 PAB/SPC Mixtures 17 2.5.3 PAB/SPC Mixtures with Ethylene Carbonate 19 2.5.4 Peroxydone/PAB Mixtures 19 2.5.4.1 Chem Agent Testing 19...Effect of Surfactant and Ethylene Carbonate (EC) Penetrant on Decontamination of HD on CARC Painted Panels 20 5. Effect of Surfactant, Alone, on...previous peroxide-based decontaminants7 (i.e., Triton® X-100 (non-ionic surfactant) and propylene carbonate [PC]) could not be used. However, there
Durak, M Zeki; Churey, John J; Worobo, Randy W
2012-07-01
Produce-associated foodborne illnesses outbreaks have highlighted the need for more effective decontamination methods to ensure the safety of fresh produce. The main objective of this study was to evaluate the individual and combined efficacies of germicidal UV light (12.5 to 500 mJ/cm(2)), acidified sodium hypochlorite (ASC 10 to 200 ppm), and mild heat (40 to 50°C) for decontaminating green onions and baby spinach infected with Escherichia coli O157:H7. Samples were inoculated by spot and dip inoculation methods to mimic surface and infiltrated E. coli O157:H7 contamination, respectively. In green onions and baby spinach, the individual efficacies of UV, ASC, and mild-heat treatments varied based on the produce type and contamination method. Following analysis of the efficacies of the single treatments, a combined treatment with 125 mJ/cm(2) UV and 200 ppm of ASC at 50°C was selected for spot-inoculated green onions, and a combined treatment with 125 mJ/cm(2) UV and 200 ppm of ASC at 20°C was selected for spot- and dip-inoculated baby spinach. While a >5-log reduction was achieved with the combination treatment for spot-inoculated green onions with an initial contamination level of 7.2 log CFU per spot, the same treatment reduced E. coli O157:H7 populations below the detection limit (<1 log) on green onions spot inoculated at a lower contamination level (4.3 log CFU per spot). On spot- and dip-inoculated baby spinach, the combined treatment reduced E. coli O157:H7 populations by 2.8 log CFU per spot and 2.6 log CFU/g, respectively. The combined treatment of 500 mJ/cm(2) UV and 200 ppm of ASC at 50°C selected for the decontamination of dip-inoculated green onions resulted in a 2.2-log CFU/g reduction. These findings suggest that when foodborne pathogens contaminate produce and subsequently infiltrate, attach to, or become localized into protected areas, the individual or combined applications of UV, ASC, and mild-heat treatments have limited decontamination efficacies on both green onions and baby spinach (<3 log). However, treatments combining UV, ASC, and mild heat could be a promising application for reducing pathogen populations (>5 log) on E. coli O157:H7 surface-contaminated green onions. This study also highlights the importance of developing and optimizing produce-specific decontamination methods to ensure the safety of fresh produce commodities.
Methods of decontaminating surfaces and related compositions
Demmer, Ricky L.; Crosby, Daniel; Norton, Christopher J.
2016-11-22
A composition of matter includes water, at least one acid, at least one surfactant, at least one fluoride salt, and ammonium nitrate. A method of decontaminating a surface includes exposing a surface to such a composition and removing the composition from the surface. Other compositions of matter include water, a fatty alcohol ether sulfate, nitrilotriacetic acid, at least one of hydrochloric acid and nitric acid, sodium fluoride, potassium fluoride, ammonium nitrate, and gelatin.
Cao, Jie; Wang, Tong; Pu, Yinfei; Tang, Zhihui; Meng, Huanxin
2018-03-01
To investigate the effects of different decontamination treatments on microstructure of titanium (Ti) surface as well as proliferation and adhesion of human gingival fibroblasts (HGFs). Ti discs with machined (M) and sand blasted, acid etched (SAE) surfaces were treated with five different decontamination treatments: (1) stainless steel curette (SSC), ultrasonic system with (2) straight carbon fiber tip (UCF) or (3) metal tip (UM), (4) rotating Ti brush (RTB), and (5) Er:YAG laser (30 mJ/pulse at 30 Hz). Surface roughness was analyzed under optical interferometry. HGFs were cultured on each disc. Proliferation and adhesive strength were analyzed. qRT-PCR and ELISA were performed to detect the RNA and protein expression of FAK, ITGB1, COL1A1, and FN1 respectively from different Ti surfaces. Surface roughness increased on M surface. Proliferation, adhesive strength and gene expression were higher on M surface than SAE surface. Decontamination treatments affected surface parameters significantly (P < 0.001), making M surface less smooth while SAE surface became less rough. SSC, UCF, UM and RTB decreased proliferation on M surfaces significantly (P < 0.05). UCF, RTB and laser increased proliferation on SAE surface significantly (P < 0.05). UM decreased adhesive strength on M surface significantly and laser increased adhesive strength on SAE surface significantly (P < 0.05). Gene expression increased with time and was altered by decontamination treatments significantly (P < 0.001). Decontamination treatments influence surface roughness and cell behavior of HGFs. Laser might be an optimal decontamination treatment which has the least negative effect on M surface and the most positive effect on SAE surface. Copyright © 2017 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Taniguchi, K.; Onda, Y.; Yoshimura, K.; Smith, H.; Brake, W.; Kubo, T.; Kuramoto, T.; Sato, T.; Onuma, S.
2016-12-01
Radionuclides such as Cs-134 and Cs-137 were widely distributed in the area affected by the accident at Fukushima Daiichi nuclear power plant. The radionuclides were deposited on the surface, absorbed by soil particles, and transported via river systems to Pacific Ocean due to rainfall events. In order to reduce air dose rate surrounding residential area, decontamination works have been conducted between 2013 and 2016 Fiscal Years. In paddy field and farmland contaminated by the fallout, 5 cm of surface soil was stripped, and then clean sands put on the surface. This work could reduce radiocaesium inventory, while the coverage of vegetation was significantly decreased. Therefore, runoff characteristics in the decontaminated area were different before and after the decontamination. Activity concentrations of particulate Cs-137 were measured in Abukuma river system and 8 small catchments located in coastal zone of Fukushima affected area. In all monitoring sites, Cs-137 concentrations have decreased over an entire monitoring period. Kuchibuto river, which is a tributary of Abukuma river showed significant effect of decontamination. In Yamakiya district, in the watershed of the tributary, the decontamination work had conducted from 2013 FY to December 2015. Particulate Cs-137 concentration at two monitoring sites located in the district showed around 30% of decline in the beginning of 2014 FY whereas the decline was not so significant at sites in lower reach of the tributary. Decontaminated paddy field and farmland can be judged as the important source of suspended sediments in the tributary.
The primary objective of these tests was to demonstrate the effectiveness of incineration as a decontamination method for explosives contaminated sails. A pilot-scale rotary kiln incinerator, manufactured by ThermAll, Inc., was used to treat both sandy and clayey...
Method for the decontamination of soil containing solid organic explosives therein
Radtke, Corey W.; Roberto, Francisco F.
2000-01-01
An efficient method for decontaminating soil containing organic explosives ("TNT" and others) in the form of solid portions or chunks which are not ordinarily subject to effective bacterial degradation. The contaminated soil is treated by delivering an organic solvent to the soil which is capable of dissolving the explosives. This process makes the explosives more bioavailable to natural bacteria in the soil which can decompose the explosives. An organic nutrient composition is also preferably added to facilitate decomposition and yield a compost product. After dissolution, the explosives are allowed to remain in the soil until they are decomposed by the bacteria. Decomposition occurs directly in the soil which avoids the need to remove both the explosives and the solvents (which either evaporate or are decomposed by the bacteria). Decomposition is directly facilitated by the solvent pre-treatment process described above which enables rapid bacterial remediation of the soil.
Low-Temperature Decontamination with Hydrogen Peroxide or Chlorine Dioxide for Space Applications
Macken, S.; Giri, K.; Walker, J. T.; Bennett, A. M.
2012-01-01
The currently used microbial decontamination method for spacecraft and components uses dry-heat microbial reduction at temperatures of >110°C for extended periods to prevent the contamination of extraplanetary destinations. This process is effective and reproducible, but it is also long and costly and precludes the use of heat-labile materials. The need for an alternative to dry-heat microbial reduction has been identified by space agencies. Investigations assessing the biological efficacy of two gaseous decontamination technologies, vapor hydrogen peroxide (Steris) and chlorine dioxide (ClorDiSys), were undertaken in a 20-m3 exposure chamber. Five spore-forming Bacillus spp. were exposed on stainless steel coupons to vaporized hydrogen peroxide and chlorine dioxide gas. Exposure for 20 min to vapor hydrogen peroxide resulted in 6- and 5-log reductions in the recovery of Bacillus atrophaeus and Geobacillus stearothermophilus, respectively. However, in comparison, chlorine dioxide required an exposure period of 60 min to reduce both B. atrophaeus and G. stearothermophilus by 5 logs. Of the three other Bacillus spp. tested, Bacillus thuringiensis proved the most resistant to hydrogen peroxide and chlorine dioxide with D values of 175.4 s and 6.6 h, respectively. Both low-temperature decontamination technologies proved effective at reducing the Bacillus spp. tested within the exposure ranges by over 5 logs, with the exception of B. thuringiensis, which was more resistant to both technologies. These results indicate that a review of the indicator organism choice and loading could provide a more appropriate and realistic challenge for the sterilization procedures used in the space industry. PMID:22492450
2009-01-01
surfaces in buildings following a terrorist attack using CB agents. Vaporized hydrogen peroxide ( VHP ) and Cl02 are decontamination technologies that...decontaminant. The focus of this technical report is the evaluation of the building interior materials and the Steris VHP technology. 15. SUBJECT...TERMS Material Compatibility VHP vaporized hydrogen peroxide 16. SECURITY CLASSIFICATION OF: a. REPORT U b. ABSTRACT U c. THIS PAGE U 17
All-Weather Hydrogen Peroxide-Based Decontamination of CBRN Contaminants
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, George W.; Procell, Lawrence R.; Sorrick, David C.
2010-03-11
A hydrogen peroxide-based decontaminant, Decon Green, is efficacious for the decontamination of chemical agents VX (S-2-(diisopropylamino)ethyl O-ethyl methylphosphonothioate), GD (Soman, pinacolyl methylphosphonofluoridate), and HD (mustard, bis(2-chloroethyl) sulfide); the biological agent anthrax (Bacillus anthracis); and radiological isotopes Cs-137 and Co-60; thus demonstrating the ability of this decontamination approach to ameliorate the aftermath of all three types of weapons of mass destruction (WMD). Reaction mechanisms afforded for the chemical agents are discussed as are rationales for the enhanced removal efficacy of recalcitrant 60Co on certain surfaces. Decontaminants of this nature can be deployed, and are effective, at very low temperatures (-32 °C),more » as shown for studies done with VX and HD simulants, without the need for external heat sources. Finally, the efficacy of a lower-logistics, dry decontaminant powder concentrate (utilizing the solid active-oxygen compounds peracetyl borate and Peroxydone) which can be reconstituted with water in the field prior to use, is presented.« less
Adé, Apolline; Chauchat, Laure; Frève, Johann-François Ouellette; Gagné, Sébastien; Caron, Nicolas; Bussières, Jean-François
2017-01-01
Background Several studies have compared cleaning procedures for decontaminating surfaces exposed to antineoplastic drugs. All of the cleaning products tested were successful in reducing most of the antineoplastic drug quantities spilled on surfaces, but none of them completely removed residual traces. Objective To assess the efficacy of various cleaning solutions for decontaminating a biological safety cabinet workbench exposed to a defined amount of cyclophosphamide. Methods In this pilot study, specific areas of 2 biological safety cabinets (class II, type B2) were deliberately contaminated with a defined quantity of cyclophosphamide (10 μg or 107 pg). Three cleaning solutions were tested: quaternary ammonium, sodium hypochlorite 0.02%, and sodium hypochlorite 2%. After cleaning, the cyclophosphamide remaining on the areas was quantified by wipe sampling. Each cleaning solution was tested 3 times, with cleaning and wipe sampling being performed 5 times for each test. Results A total of 57 wipe samples were collected and analyzed. The average recovery efficiency was 121.690% (standard deviation 5.058%). The decontamination efficacy increased with the number of successive cleaning sessions: from 98.710% after session 1 to 99.997% after session 5 for quaternary ammonium; from 97.027% to 99.997% for sodium hypochlorite 0.02%; and from 98.008% to 100% for sodium hypochlorite 2%. Five additional cleaning sessions performed after the main study (with detergent and sodium hypochlorite 2%) were effective to complete the decontamination, leaving no detectable traces of the drug. Conclusions All of the cleaning solutions reduced contamination of biological safety cabinet workbenches exposed to a defined amount of cyclophosphamide. Quaternary ammonium and sodium hypochlorite (0.02% and 2%) had mean efficacy greater than 97% for removal of the initial quantity of the drug (107 pg) after the first cleaning session. When sodium hypochlorite 2% was used, fewer cleaning sessions were required to complete decontamination. Further studies should be conducted to identify optimal cleaning strategies to fully eliminate traces of hazardous drugs. PMID:29298999
TATARELLI, P.; LORENZI, I.; CAVIGLIA, I.; SACCO, R.A.; LA MASA, D.
2016-01-01
Summary Introduction. Hand decontamination with alcohol-based antiseptic agents is considered the best practise to reduce healthcare associated infections. We present a new method to monitor hand hygiene, introduced in a tertiary care pediatric hospital in Northern Italy, which estimates the mean number of daily hand decontamination procedures performed per patient. Methods. The total amount of isopropyl alcohol and chlorhexidine solution supplied in a trimester to each hospital ward was put in relation with the number of hospitalization days, and expressed as litres/1000 hospitalization-days (World Health Organization standard method). Moreover, the ratio between the total volume of hand hygiene products supplied and the effective amount of hand disinfection product needed for a correct procedure was calculated. Then, this number was divided by 90 (days in a quarter) and then by the mean number of bed active in each day in a Unit, resulting in the mean estimated number of hand hygiene procedures per patient per day (new method). Results. The two methods had similar performance for estimating the adherence to correct hand disinfection procedures. The new method identified wards and/or periods with high or low adherence to the procedure and indicated where to perform interventions and their effectiveness. The new method could result easy-to understand also for non-infection control experts. Conclusions. This method can help non-infection control experts to understand adherence to correct hand-hygiene procedures and improve quality standards. PMID:28167854
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bito, T.; Takase, A.
Decontamination of the living oyster was studied by Y/sup 90/or Y/sup 91/ -labeled coliform bacteria. At low temperature, precultural temperature affected the contamination of the oyster but the uptake of bacteria by the oyster was distinctly observed below 5 deg C. In a study on elapsing change of contamination, it was determined that the whole bacterial load of the oyster depended mainly on the gill, but was not negligible on the digestive tract. The contaminating rate of the oyster was successfully measured by automatic recording of the shift of radioactivity in the contaminated cultural water with a dip-type G-M countermore » ratemeter and chart recorder, because the bacterial concentration of the closed cultural water decrease according to the bacterial uptake of the oyster. On decontamination of the oyster, it was observed that the most effective temperature existed in the region of 15 to 25 deg C, and at the upper or lower of this region the decontaminating efficiency decreased. As for the exchange rate of the culture water, the decontaminating effect on the oyster was proportional to an increase of the rate to 7.5 times per hour. However, more was of no effect. An increase in the cultured water volume was harmful for the decontamination of the oyster because of the exchanging efficiency of the water. (P.C.H.)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Watkins, R.M.
1959-03-01
Developments relative to decontamination achieved under the Yankee Reasearch and Development program are reported. The decontamination of a large test loop which had been used to conduct corrosion rate studies for the Yankee reactor program is described. The basic permanganate-citrate decontamination procedure suggested for application in Yankee reactor primary system cleanup was used. A study of the chemistry of this decontamination operation is presented, together with conclusions pertaining to the effectiveness of the solutions under the conditions studied. In an attempt to further improve the efficiency of the procedure, an additional series of static and dynamic tests was performcd usingmore » contaminated sections of stainless steel tubing from the original SlW steam generator. Survival variables in the process (reagent composition, contact time, temperature, and flow velocity) were studied. The changes in decontamination efficiency produced by these variations are discussed and compared with results obtained throughthe use of similar procedures. Based on the observations made, conclusions are drawn concerning the optimum conditions for this cleanup process, a new set of suggested basic permanganate-citrate decontamination instructions is presented, and recommendations are made concerning future studies involving this procedure. (auth)« less
Perez, Keila L; Lucia, Lisa M; Cisneros-Zevallos, Luis; Castillo, Alejandro; Taylor, T Matthew
2012-05-01
While there is strong focus on eliminating pathogens from produce at a commercial level, consumers can employ simple methods to achieve additional pathogen reductions in the domestic kitchen. To determine the ability of antimicrobials to decontaminate peppers, samples of green bell pepper were inoculated with Salmonella enterica and Escherichia coli O157:H7 and then immersed in 3% (v/v) hydrogen peroxide (H₂O₂), 2.5% (v/v) acetic acid (AA), 70% (v/v) ethyl alcohol (EtOH), or sterile distilled water (SDW). The potential for transfer of pathogens from contaminated peppers to other non-contaminated produce items, and the effect of knife disinfection in preventing this cross contamination, were also tested. Knife disinfection procedures were evaluated by chopping inoculated peppers into 1 cm² pieces with kitchen knives. Experimental knives were then treated by either no treatment (control), wiping with a dry sterile cotton towel, rinsing under running warm water for 5 or 10s, or applying a 1% (v/v) lauryl sulfate-based detergent solution followed by rinsing with warm running water for 10s. Following disinfection treatment, knives were used to slice cucumbers. Exposure to H₂O₂ for 5 min and EtOH for 1 min resulted in reductions of 1.3±0.3 log₁₀ CFU/cm² for both pathogens. A 5 min exposure to AA resulted in a reduction of S. enterica of 1.0±0.7 log₁₀ CFU/cm² and E. coli of 0.7±0.8 log₁₀ CFU/cm². No differences (p ≥ 0.05) were found between numbers of pathogens on knives and numbers of pathogens transferred to cucumber slices, suggesting that organisms remaining on knife surfaces were transferred to cucumbers during slicing. Findings suggest that EtOH and H₂O₂ may be effective antimicrobials for in-home decontamination of peppers, and that use of detergent and warm water is effective for decontamination of implements used during meal preparation. Published by Elsevier B.V.
Ares I Reaction Control System Propellant Feedline Decontamination Modeling
NASA Technical Reports Server (NTRS)
Pasch, James J.
2010-01-01
The objective of the work presented here is to quantify the effects of purge gas temperature, pressure, and mass flow rate on Hydrazine (Hz) decontamination rates of the Ares I Roll Control System and Reaction Control System. A survey of experts in this field revealed the absence of any decontamination rate prediction models. Three basic decontamination methods were identified for analysis and modeling. These include low pressure eduction, high flow rate purge, and pulse purge. For each method, an approach to predict the Hz mass transfer rate, as a function of system pressure, temperature, and purge gas mass flow rate, is developed based on the applicable physics. The models show that low pressure eduction is two orders of magnitude more effective than the high velocity purge, which in turn is two orders of magnitude more effective than the pure diffusion component of pulse purging of deadheads. Eduction subjects the system to low pressure conditions that promote the extraction of Hz vapors. At 120 F, Hz is saturated at approximately 1 psia. At lower pressures and 120 F, Hz will boil, which is an extremely efficient means to remove liquid Hz. The Hz boiling rate is predicted by equating the rate at which energy is added to the saturated liquid Hz through heaters at the tube outer wall with the energy removed from the liquid through evaporation. Boil-off fluxes were predicted by iterating through the range of local pressures with limits set by the minimum allowed pressure of 0.2 psia and maximum allowed wall temperature of 120 F established by the heaters, which gives a saturation pressure of approximately 1.0 psia. Figure 1 shows the resulting boil-off fluxes as a function of local eduction pressure. As depicted in figure 1, the flux is a strong inverse function of eduction pressure, and that minimizing the eduction pressure maximizes the boil-off flux. Also, higher outer wall temperatures lead to higher boil-off fluxes and allow for boil-off over a greater range of eduction pressures.
Potential of Biological Agents in Decontamination of Agricultural Soil
Javaid, Muhammad Kashif; Ashiq, Mehrban; Tahir, Muhammad
2016-01-01
Pesticides are widely used for the control of weeds, diseases, and pests of cultivated plants all over the world, mainly since the period after the Second World War. The use of pesticides is very extensive to control harm of pests all over the globe. Persistent nature of most of the synthetic pesticides causes serious environmental concerns. Decontamination of these hazardous chemicals is very essential. This review paper elaborates the potential of various biological agents in decontamination of agricultural soils. The agricultural crop fields are contaminated by the periodic applications of pesticides. Biodegradation is an ecofriendly, cost-effective, highly efficient approach compared to the physical and chemical methods which are expensive as well as unfriendly towards environment. Biodegradation is sensitive to the concentration levels of hydrogen peroxide and nitrogen along with microbial community, temperature, and pH changes. Experimental work for optimum conditions at lab scale can provide very fruitful results about specific bacterial, fungal strains. This study revealed an upper hand of bioremediation over physicochemical approaches. Further studies should be carried out to understand mechanisms of biotransformation. PMID:27293964
Potential of Biological Agents in Decontamination of Agricultural Soil.
Javaid, Muhammad Kashif; Ashiq, Mehrban; Tahir, Muhammad
2016-01-01
Pesticides are widely used for the control of weeds, diseases, and pests of cultivated plants all over the world, mainly since the period after the Second World War. The use of pesticides is very extensive to control harm of pests all over the globe. Persistent nature of most of the synthetic pesticides causes serious environmental concerns. Decontamination of these hazardous chemicals is very essential. This review paper elaborates the potential of various biological agents in decontamination of agricultural soils. The agricultural crop fields are contaminated by the periodic applications of pesticides. Biodegradation is an ecofriendly, cost-effective, highly efficient approach compared to the physical and chemical methods which are expensive as well as unfriendly towards environment. Biodegradation is sensitive to the concentration levels of hydrogen peroxide and nitrogen along with microbial community, temperature, and pH changes. Experimental work for optimum conditions at lab scale can provide very fruitful results about specific bacterial, fungal strains. This study revealed an upper hand of bioremediation over physicochemical approaches. Further studies should be carried out to understand mechanisms of biotransformation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Creasy, W.R.; Brickhouse, M.D.; Morrisse, K.M.
1999-07-01
Decontamination waste from chemical weapons (CW) agents has been stored in ton containers on Johnston Atoll since 1971. The waste was recently sampled and analyzed to determine its chemical composition in preparation for future cleanups. Due to the range of products and analytical requirements, multiple chromatographic and spectroscopic methods were necessary, including gas chromatography/mass spectrometry (GC/MS), gas chromatography/atomic emission detection (GC/AED), liquid chromatography/mass spectrometry (LC/MS), capillary electrophoresis (CE), and nuclear magnetic resonance spectroscopy (NMR). The samples were screened for residual agents. No residual sarin (GB) or VX was found to detection limits of 20 ng/mL, but 3% of the samplesmore » contained residual sulfur mustard (HD) at < 140 ng/mL. Decontamination products of agents were identified. The majority (74%) of the ton containers were documented correctly, in that the observed decontamination products were in agreement with the labeled agent type, but for a number of the containers, the contents were not in agreement with the labels. In addition, arsenic compounds that are decontamination products of the agent lewisite (L) were observed in a few ton containers, suggesting that lewisite was originally present but not documented. This study was a prototype to demonstrate the level of effort required to characterize old bulk CW-related waste.« less
Bench, Thomas R.; McCann, Larry D.
1989-01-01
A method for the in situ decontamination of underground water containing -volatile contaminants comprising continuously contacting in situ underground water containing non-volatile contaminants with a liquid-absorbent material possessing high capillary activity, allowing the non-volatile contaminants to deposit in the material while the water moves upwardly through the material by capillary action, allowing substantially decontaminated water to be volatilized by impinging solar radiation, and then allowing the volatilized water to escape from the material into the atmosphere. An apparatus for the in situ decontamination of underground water containing non-volatile contaminants comprising at least one water-impermeable elongated conduit having an upper portion and first and second open ends and containing a homogeneous liquid-absorbent material possessing high capillary activity, means for supporting said conduit, and means for accelerating the escape of the volatilized decontamined water from the material, said means being detachably connected to the second end of the elongated conduit; wherein when underground water contaminated with non-volatile contaminants is continuously contacted in situ with the material contained in the first end of the conduit and the second end of the conduit is placed in contact with atmospheric air, non-volatile contaminants deposit in said material as the water moves upwardly through the material by capillary action, is then volatilized by impinging solar energy and escapes to the atmosphere.
Food decontamination using nanomaterials
USDA-ARS?s Scientific Manuscript database
The research indicates that nanomaterials including nanoemulsions are promising decontamination media for the reduction of food contaminating pathogens. The inhibitory effect of nanoparticles for pathogens could be due to deactivate cellular enzymes and DNA; disrupting of membrane permeability; and/...
Letters, S; Smith, A J; McHugh, S; Bagg, J
2005-10-22
This study examined methods used for reprocessing endodontic instruments in general dental practice and determined the degree of residual visual contamination and blood contamination on 250 reprocessed files collected from 25 general dental practices. A questionnaire was administered to 25 general dental practitioners to obtain information on the re-processing of used endodontic files. Ten files which had been used and reprocessed were also collected from each practice. These were examined visually under a dissecting light microscope for residual contamination and then tested for blood deposits using the Kastle-Meyer test. Nineteen of the 25 practices used stainless steel hand files. No practitioners used endodontic files as single use devices. Ninety-two per cent of the practitioners discarded and replaced files when they were bent or damaged. Several decontamination methods were reported. The two combinations employed most frequently were manual cleaning and autoclaving or manual cleaning, followed by ultrasonic cleaning and autoclaving. Of the 250 files, 75% showed some degree of visual contamination and seven percent tested positive for residual blood. Blood contaminated files were significantly more heavily contaminated when examined visually. Large variations were found in residual contamination of files collected from practices using the same methods of decontamination. While all practitioners re-used endodontic files, the variations in decontamination methods reported indicate a lack of clarity on best practice. This study demonstrates that endodontic files are not reliably decontaminated by methods currently employed in dental practice.
NASA Astrophysics Data System (ADS)
Mukisa, Ivan M.; Muyanja, Charles M. B. K.; Byaruhanga, Yusuf B.; Schüller, Reidar B.; Langsrud, Thor; Narvhus, Judith A.
2012-03-01
Malted and un-malted sorghum ( Sorghum bicolor (L.) Moench) flour was gamma irradiated with a dose of 10 kGy and then re-irradiated with 25 kGy. The effects of irradiation on microbial decontamination, amylase activity, fermentability (using an amylolytic L. plantarum MNC 21 strain), starch granule structure and viscosity were determined. Standard methods were used during determinations. The 10 kGy dose had no effect on microbial load of un-malted flour but reduced that of malted flour by 3 log cycles. Re-irradiation resulted in complete decontamination. Irradiation of malt caused a significant ( p<0.05) reduction in alpha and beta amylase activity (22% and 32%, respectively). Irradiation of un-malted flour increased the rates of utilization of glucose and maltose by 53% and 100%, respectively, during fermentation. However, microbial growth, rate of lactic acid production, final lactic acid concentration and pH were not affected. Starch granules appeared normal externally even after re-irradiation, however, granules ruptured and dissolved easily after hydration and gelatinization. Production of high dry matter density porridge (200 g dry matter/L) with a viscosity of 3500 cP was achieved by irradiation of un-malted flout at 10 kGy. Gamma irradiation can be used to decontaminate flours and could be utilized to produce weaning porridge from sorghum.
Method of treating contaminated HEPA filter media in pulp process
Hu, Jian S.; Argyle, Mark D.; Demmer, Ricky L.; Mondok, Emilio P.
2003-07-29
A method for reducing contamination of HEPA filters with radioactive and/or hazardous materials is described. The method includes pre-processing of the filter for removing loose particles. Next, the filter medium is removed from the housing, and the housing is decontaminated. Finally, the filter medium is processed as pulp for removing contaminated particles by physical and/or chemical methods, including gravity, flotation, and dissolution of the particles. The decontaminated filter medium is then disposed of as non-RCRA waste; the particles are collected, stabilized, and disposed of according to well known methods of handling such materials; and the liquid medium in which the pulp was processed is recycled.
Mosci, D; Marmo, G W; Sciolino, L; Zaccaro, C; Antonellini, R; Accogli, L; Lazzarotto, T; Mongardi, M; Landini, M P
2017-10-01
New technologies for automated disinfection have been developed, including the use of hydrogen peroxide atomized by specific equipment, with associated silver compounds. To compare the effectiveness of an automated disinfection system with hydrogen peroxide <8% and silver ion versus a manual method with 0.5% sodium hypochlorite solution when evaluating the reduction of microbial mesophilic contamination and Clostridium difficile presence; and to evaluate the time required for both of these processes. This was a randomized multicentre trial performed in different hospital wards that had been occupied previously by patients with Clostridium difficile infection. When patients were discharged their rooms were randomized to one of two decontamination arms. The surfaces where sampled using swabs, before and after disinfection. Swab samples were cultured for quantitative detection of microbial mesophilic contamination and qualitative detection of C. difficile. Before disinfection, 13% of surfaces decontaminated with hydrogen peroxide and silver ions and 20% of surfaces decontaminated with sodium hypochlorite showed presence of C. difficile spores. After disinfection, the samples containing C. difficile were 0% (P < 0.001) in the group decontaminated with hydrogen peroxide and silver ions, and were 3% (P < 0.001) in the group decontaminated with sodium hypochlorite. This difference was not statistically significant; nor was the difference in the reduction of the microbial mesophilic contamination. The differences between the groups were not statistically significant; however, the disinfection with hydrogen peroxide and silver ions is preferable due to less dependence on operators. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Huang, Yu-Tuan; Hseu, Zeng-Yei; Hsi, Hsing-Cheng
2011-08-01
Thermal treatment is a useful tool to remove Hg from contaminated soils. However, thermal treatment may greatly alter the soil properties and cause the coexisting contaminants, especially trace metals, to transform and repartition. The metal repartitioning may increase the difficulty in the subsequent process of a treatment train approach. In this study, three Hg-contaminated soils were thermally treated to evaluate the effects of treating temperature and duration on Hg removal. Thermogravimetric analysis was performed to project the suitable heating parameters for subsequent bench-scale fixed-bed operation. Results showed that thermal decontamination at temperature>400°C successfully lowered the Hg content to<20 mg kg(-1). The organic carbon content decreased by 0.06-0.11% and the change in soil particle size was less significant, even when the soils were thermally treated to 550°C. Soil clay minerals such as kaolinite were shown to be decomposed. Aggregates were observed on the surface of soil particles after the treatment. The heavy metals tended to transform into acid-extractable, organic-matter bound, and residual forms from the Fe/Mn oxide bound form. These results suggest that thermal treatment may markedly influence the effectiveness of subsequent decontamination methods, such as acid washing or solvent extraction. Copyright © 2011 Elsevier Ltd. All rights reserved.
A Novel Method to Decontaminate Surgical Instruments for Operational and Austere Environments.
Knox, Randy W; Demons, Samandra T; Cunningham, Cord W
2015-12-01
The purpose of this investigation was to test a field-expedient, cost-effective method to decontaminate, sterilize, and package surgical instruments in an operational (combat) or austere environment using chlorhexidine sponges, ultraviolet C (UVC) light, and commercially available vacuum sealing. This was a bench study of 4 experimental groups and 1 control group of 120 surgical instruments. Experimental groups were inoculated with a 10(6) concentration of common wound bacteria. The control group was vacuum sealed without inoculum. Groups 1, 2, and 3 were first scrubbed with a chlorhexidine sponge, rinsed, and dried. Group 1 was then packaged; group 2 was irradiated with UVC light, then packaged; group 3 was packaged, then irradiated with UVC light through the bag; and group 4 was packaged without chlorhexidine scrubbing or UVC irradiation. The UVC was not tested by itself, as it does not grossly clean. The instruments were stored overnight and tested for remaining colony forming units (CFU). Data analysis was conducted using analysis of variance and group comparisons using the Tukey method. Group 4 CFU was statistically greater (P < .001) than the control group and groups 1 through 3. There was no statistically significant difference between the control group and groups 1 through 3. Vacuum sealing of chlorhexidine-scrubbed contaminated instruments with and without handheld UVC irradiation appears to be an acceptable method of field decontamination. Chlorhexidine scrubbing alone achieved a 99.9% reduction in CFU, whereas adding UVC before packaging achieved sterilization or 100% reduction in CFU, and UVC through the bag achieved disinfection. Published by Elsevier Inc.
Evaluating the Effects of Gamma-Irradiation for Decontamination of Medicinal Cannabis.
Hazekamp, Arno
2016-01-01
In several countries with a National medicinal cannabis program, pharmaceutical regulations specify that herbal cannabis products must adhere to strict safety standards regarding microbial contamination. Treatment by gamma irradiation currently seems the only method available to meet these requirements. We evaluated the effects of irradiation treatment of four different cannabis varieties covering different chemical compositions. Samples were compared before and after standard gamma-irradiation treatment by performing quantitative UPLC analysis of major cannabinoids, as well as qualitative GC analysis of full cannabinoid and terpene profiles. In addition, water content and microscopic appearance of the cannabis flowers was evaluated. This study found that treatment did not cause changes in the content of THC and CBD, generally considered as the most important therapeutically active components of medicinal cannabis. Likewise, the water content and the microscopic structure of the dried cannabis flowers were not altered by standard irradiation protocol in the cannabis varieties studied. The effect of gamma-irradiation was limited to a reduction of some terpenes present in the cannabis, but keeping the terpene profile qualitatively the same. Based on the results presented in this report, gamma irradiation of herbal cannabis remains the recommended method of decontamination, at least until other more generally accepted methods have been developed and validated.
Evaluating the Effects of Gamma-Irradiation for Decontamination of Medicinal Cannabis
Hazekamp, Arno
2016-01-01
In several countries with a National medicinal cannabis program, pharmaceutical regulations specify that herbal cannabis products must adhere to strict safety standards regarding microbial contamination. Treatment by gamma irradiation currently seems the only method available to meet these requirements. We evaluated the effects of irradiation treatment of four different cannabis varieties covering different chemical compositions. Samples were compared before and after standard gamma-irradiation treatment by performing quantitative UPLC analysis of major cannabinoids, as well as qualitative GC analysis of full cannabinoid and terpene profiles. In addition, water content and microscopic appearance of the cannabis flowers was evaluated. This study found that treatment did not cause changes in the content of THC and CBD, generally considered as the most important therapeutically active components of medicinal cannabis. Likewise, the water content and the microscopic structure of the dried cannabis flowers were not altered by standard irradiation protocol in the cannabis varieties studied. The effect of gamma-irradiation was limited to a reduction of some terpenes present in the cannabis, but keeping the terpene profile qualitatively the same. Based on the results presented in this report, gamma irradiation of herbal cannabis remains the recommended method of decontamination, at least until other more generally accepted methods have been developed and validated. PMID:27199751
Lydon, Helen L; Hall, Charlotte A; Dalton, Christopher H; Chipman, J Kevin; Graham, John S; Chilcott, Robert P
2017-08-01
Previous studies have demonstrated that haemostatic products with an absorptive mechanism of action retain their clotting efficiency in the presence of toxic materials and are effective in decontaminating chemical warfare (CW) agents when applied to normal, intact skin. The purpose of this in vitro study was to assess three candidate haemostatic products for effectiveness in the decontamination of superficially damaged porcine skin exposed to the radiolabelled CW agents, soman (GD), VX and sulphur mustard (HD). Controlled physical damage (removal of the upper 100 μm skin layer) resulted in a significant enhancement of the dermal absorption of all three CW agents. Of the haemostatic products assessed, WoundStat™ was consistently the most effective, being equivalent in performance to a standard military decontaminant (fuller's earth). These data suggest that judicious application of haemostatic products to wounds contaminated with CW agents may be a viable option for the clinical management of casualties presenting with contaminated, haemorrhaging injuries. Further studies using a relevant animal model are required to confirm the potential clinical efficacy of WoundStat™ for treating wounds contaminated with CW agents. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.
Decontamination formulation with sorbent additive
Tucker; Mark D. , Comstock; Robert H.
2007-10-16
A decontamination formulation and method of making that neutralizes the adverse health effects of both chemical and biological compounds, especially chemical warfare (CW) and biological warfare (BW) agents, and toxic industrial chemicals. The formulation provides solubilizing compounds that serve to effectively render the chemical and biological compounds, particularly CW and BW compounds, susceptible to attack, and at least one reactive compound that serves to attack (and detoxify or kill) the compound. The formulation includes at least one solubilizing agent, a reactive compound, a bleaching activator, a sorbent additive, and water. The highly adsorbent, water-soluble sorbent additive (e.g., sorbitol or mannitol) is used to "dry out" one or more liquid ingredients, such as the liquid bleaching activator (e.g., propylene glycol diacetate or glycerol diacetate) and convert the activator into a dry, free-flowing powder that has an extended shelf life, and is more convenient to handle and mix in the field.
Full Scale Drinking Water System Decontamination at the Water Security Test Bed.
Szabo, Jeffrey; Hall, John; Reese, Steve; Goodrich, Jim; Panguluri, Sri; Meiners, Greg; Ernst, Hiba
2018-03-20
The EPA's Water Security Test Bed (WSTB) facility is a full-scale representation of a drinking water distribution system. In collaboration with the Idaho National Laboratory (INL), EPA designed the WSTB facility to support full-scale evaluations of water infrastructure decontamination, real-time sensors, mobile water treatment systems, and decontamination of premise plumbing and appliances. The EPA research focused on decontamination of 1) Bacillus globigii (BG) spores, a non-pathogenic surrogate for Bacillus anthracis and 2) Bakken crude oil. Flushing and chlorination effectively removed most BG spores from the bulk water but BG spores still remained on the pipe wall coupons. Soluble oil components of Bakken crude oil were removed by flushing although oil components persisted in the dishwasher and refrigerator water dispenser. Using this full-scale distribution system allows EPA to 1) test contaminants without any human health or ecological risk and 2) inform water systems on effective methodologies responding to possible contamination incidents.
Pichler, G; Pux, C; Babeluk, R; Hermann, B; Stoiser, E; De Campo, A; Grisold, A; Zollner-Schwetz, I; Krause, R; Schippinger, W
2018-01-01
Methicillin-resistant Staphylococcus aureus (MRSA) decontamination regimens predominantly use chlorhexidine bathing in combination with mupirocin nasal ointment. However, resistances in Staphylococcus aureus strains are increasingly common and there is a need of alternative, safe and feasible protocols. This interventional cohort study performed at the Albert Schweitzer Hospital in Graz, Austria, aimed to (1) determine MRSA prevalence at different body sites and (2) assess the efficacy of the decontamination using octenidine-based leave-on products added to existing robust infection control measures. All inpatients of this tertiary care hospital being treated in geriatric medical wards (GWs) and apallic care units (ACUs) were screened for MRSA and decontamination rates were determined after one, two or three decontamination cycles, respectively. At baseline, MRSA was detected in 25 of the 126 patients screened (19.8%). We found MRSA in 13/126 (10.3%) swabs from nasal vestibules, in 12/126 (9.5%) skin swabs, in 11/51 (21.6%) swabs from PEG-stomata or suprapubic catheters and in 8/13 (61.5%) tracheostomata swabs. A maximum of three 5-day decontamination cycles reduced the number of MRSA positive patients by 68.0%. Excluding non-compliant and deceased patients, decontamination reduced MRSA carriage by 93.3% (n = 15). No adverse events related to the applied decontamination regimen occurred. Exclusive screening of the nose might underreport MRSA prevalence rates. In this study, decontamination with octenidine-based leave-on products was safe and effective in a critical patient population.
2008-09-01
related scenarios related to US armed forces around the world . In the civilian setting, complete decontamination is the only accepted criteria before a...observation, a door for sample introduction, and four ports on the front panel for sensor placement. All glass surfaces were covered when used with CD gas...1999, 281, 1735-1745. 9. AOAC International Method 966.04; Official Methods of Analisis , 21’t ed.; Chapter 6: AOAC International: Gaithersburg, MD
Removal of radioactive materials and heavy metals from water using magnetic resin
Kochen, R.L.; Navratil, J.D.
1997-01-21
Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately. 9 figs.
Removal of radioactive materials and heavy metals from water using magnetic resin
Kochen, Robert L.; Navratil, James D.
1997-01-21
Magnetic polymer resins capable of efficient removal of actinides and heavy metals from contaminated water are disclosed together with methods for making, using, and regenerating them. The resins comprise polyamine-epichlorohydrin resin beads with ferrites attached to the surfaces of the beads. Markedly improved water decontamination is demonstrated using these magnetic polymer resins of the invention in the presence of a magnetic field, as compared with water decontamination methods employing ordinary ion exchange resins or ferrites taken separately.
Palamarchuk, Marina; Egorin, Andrey; Tokar, Eduard; Tutov, Mikhail; Marinin, Dmitry; Avramenko, Valentin
2017-01-05
The origin of the emergence of radioactive contamination not removable in the process of acid-base regeneration of ion-exchange resins used in treatment of technological media and liquid radioactive waste streams has been determined. It has been shown that a majority of cesium radionuclides not removable by regeneration are bound to inorganic deposits on the surface and inside the ion-exchange resin beads. The nature of the above inorganic inclusions has been investigated by means of the methods of electron microscopy, IR spectrometry and X-ray diffraction. The method of decontamination of spent ion-exchange resins and zeolites contaminated with cesium radionuclides employing selective resorcinol-formaldehyde resins has been suggested. Good prospects of such an approach in deep decontamination of spent ion exchangers have been demonstrated. Copyright © 2016 Elsevier B.V. All rights reserved.
Gut, Ian M; Bartlett, Ryan A; Yeager, John J; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul; Karaolis, David K R
2016-05-01
Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies,Yersinia pestis persistence as a function of surface type at 21 °C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. Copyright © 2016, American Society for Microbiology. All Rights Reserved.
Bartlett, Ryan A.; Yeager, John J.; Leroux, Brian; Ratnesar-Shumate, Shanna; Dabisch, Paul
2016-01-01
ABSTRACT Public health and decontamination decisions following an event that causes indoor contamination with a biological agent require knowledge of the environmental persistence of the agent. The goals of this study were to develop methods for experimentally depositing bacteria onto indoor surfaces via aerosol, evaluate methods for sampling and enumerating the agent on surfaces, and use these methods to determine bacterial surface decay. A specialized aerosol deposition chamber was constructed, and methods were established for reproducible and uniform aerosol deposition of bacteria onto four coupon types. The deposition chamber facilitated the control of relative humidity (RH; 10 to 70%) following particle deposition to mimic the conditions of indoor environments, as RH is not controlled by standard heating, ventilation, and air conditioning (HVAC) systems. Extraction and culture-based enumeration methods to quantify the viable bacteria on coupons were shown to be highly sensitive and reproducible. To demonstrate the usefulness of the system for decay studies, Yersinia pestis persistence as a function of surface type at 21°C and 40% RH was determined to be >40%/min for all surfaces. Based upon these results, at typical indoor temperature and RH, a 6-log reduction in titer would expected to be achieved within 1 h as the result of environmental decay on surfaces without active decontamination. The developed approach will facilitate future persistence and decontamination studies with a broad range of biological agents and surfaces, providing agent decay data to inform both assessments of risk to personnel entering a contaminated site and decontamination decisions following biological contamination of an indoor environment. IMPORTANCE Public health and decontamination decisions following contamination of an indoor environment with a biological agent require knowledge of the environmental persistence of the agent. Previous studies on Y. pestis persistence have utilized large liquid droplet deposition to provide persistence data. As a result, methods were developed to deposit aerosols containing bacteria onto indoor surfaces, reproducibly enumerate bacteria harvested from coupons, and determine surface decay utilizing Y. pestis. The results of this study provide foundational methods required to evaluate surface decay of bacteria and potentially other biological agents, such as viruses, in aerosol particles as a function of surface type and environment. Integrating the data from both aerosol and liquid deposition surface decay studies will provide medical and public health personnel with a more complete understanding of agent persistence on surfaces in contaminated areas for assessment of health risks and to inform decontamination decisions. PMID:26944839
de Waal, Yvonne C M; Raghoebar, Gerry M; Huddleston Slater, James J R; Meijer, Henny J A; Winkel, Edwin G; van Winkelhoff, Arie Jan
2013-02-01
The objective of this randomized, double-blind, placebo-controlled trial was to study the effect of implant surface decontamination with chlorhexidine (CHX)/cetylpyridinium chloride (CPC) on microbiological and clinical parameters. Thirty patients (79 implants) with peri-implantitis were treated with resective surgical treatment consisting of apically re-positioned flap, bone re-contouring and surface debridement and decontamination. Patients were randomly allocated to decontamination with 0.12% CHX + 0.05% CPC (test-group) or a placebo-solution (without CHX/CPC, placebo-group). Microbiological parameters were recorded during surgery; clinical and radiographical parameters were recorded before (pre-) treatment (baseline), and at 3, 6 and 12 months after treatment. Nine implants in two patients in the placebo-group were lost due to severe persisting peri-implantitis. Both decontamination procedures resulted in significant reductions of bacterial load on the implant surface, but the test-group showed a significantly greater reduction than the placebo-group (log 4.21 ± 1.89 versus log 2.77 ± 2.12, p = 0.006). Multilevel analysis showed no differences between both groups in the effect of the intervention on bleeding, suppuration, probing pocket depth and radiographical bone loss over time. Implant surface decontamination with 0.12% CHX + 0.05% CPC in resective surgical treatment of peri-implantitis leads to a greater immediate suppression of anaerobic bacteria on the implant surface than a placebo-solution, but does not lead to superior clinical results. The long-term microbiological effect remains unknown. © 2012 John Wiley & Sons A/S.
Moore, C A; Wilkinson, S C; Blain, P G; Dunn, M; Aust, G A; Williams, F M
2014-08-17
Organophosphates (OPs) are widely used in agriculture. Many studies have investigated the capability of personal protective equipment (PPE) to reduce chemical exposure; however, investigations into the protective effect of 'every-day' clothing are rare. The purpose of this study was to investigate the protective effect of 'every-day' clothing against dermal exposure and to measure early decontamination of skin following exposure to chlorpyrifos and dichlorvos. Using human skin in vitro, absorption of (14)C-labelled chlorpyrifos (500 ng/cm(2)), was shown to be significantly reduced when applied to clothed skin (cotton shirt), regardless of application vehicle (isopropanol (IPA) or propylene glycol (PG)). The majority of applied dose was retained within the clothing after 4 h exposure. Significant reduction in absorption of chlorpyrifos (in PG) was seen through clothed skin when supplemented with skin decontamination at 4 h, compared with clothed skin decontaminated after 24 h, however, this was not observed with IPA. Absorption of dichlorvos (5 μg/cm(2)) was greater through unclothed skin than chlorpyrifos for all vehicles (IPA, isopropyl myristate (IPM) and PG). Significant reduction in absorption was observed when decontaminating clothed skin at 30 min, compared with decontamination at 24 h (post-exposure) for all vehicles. indicate that 'every-day' clothing is effective at reducing exposure to chemicals in contact with skin. Washing the skin surface immediately following removal of exposed clothing can further reduce exposure, depending on the properties of the chemical and vehicle applied. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hoyt, K.R.; Pavelek, M.D. II
1987-01-01
Following the accident at Three Mile Island Unit 2 (TMI-2) substantial areas in the auxiliary and fuel-handling buildings were contaminated. Overflowing sumps backed up floor drains and contaminated a substantial portion of the 282-ft elevation floor. In addition, contamination was spread into the overheads when the nitrogen purge system, which had become internally contaminated, was relieved of overpressure. Operating experience with the Kelly Decontamination System has been exceptional. The system has been defined as a tool of the trade for labor personnel to operate as part of their duties. A detailed training program was provided by the Kelly Division ofmore » Container Products Corporation for the engineers who then trained labor personnel in the operation of the equipment. There were very few problems with personnel on the equipment for routine decontamination operations. The Kelly Decontamination System has proven to be a dose and cost-effective alternative to hands-on decontamination techniques at TMI-2 and should have wide application for large-scale decontamination operations.« less
An Organic Decontamination Method for Sampling Devices used in Life-detection Studies
NASA Technical Reports Server (NTRS)
Eigenbrode, Jennifer; Maule, Jake; Wainwright, Norm; Steele, Andrew; Amundsen, Hans E.F.
2008-01-01
Organic decontamination of sampling and storage devices are crucial steps for life-detection, habitability, and ecological investigations of extremophiles living in the most inhospitable niches of Earth, Mars and elsewhere. However, one of the main stumbling blocks for Mars-analogue life-detection studies in terrestrial remote field-sites is the capability to clean instruments and sampling devices to organic levels consistent with null values. Here we present a new seven-step, multi-reagent cleaning and decontamination protocol that was adapted and tested on a glacial ice-coring device and on a rover-guided scoop used for sediment sampling both deployed multiple times during two field seasons of the Arctic Mars Analog Svalbard Expedition AMASE). The effectiveness of the protocols for both devices was tested by (1)in situ metabolic measurements via APT, (2)in situ lipopolysacchride (LPS) quantifications via low-level endotoxin assays, and(3) laboratory-based molecular detection via gas chromatography-mass spectrometry. Our results show that the combination and step-wise application of disinfectants with oxidative and solvation properties for sterilization are effective at removing cellular remnants and other organic traces to levels necessary for molecular organic- and life-detection studies. The validation of this seven-step protocol - specifically for ice sampling - allows us to proceed with confidence in kmskia4 analogue investigations of icy environments. However, results from a rover scoop test showed that this protocol is also suitable for null-level decontamination of sample acquisition devices. Thus, this protocol may be applicable to a variety of sampling devices and analytical instrumentation used for future astrobiology missions to Enceladus, and Europa, as well as for sample-return missions.
Szabo, Jeff; Minamyer, Scott
2014-11-01
This report summarizes the current state of knowledge on the persistence of chemical contamination on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some chemical contaminants, but important data gaps remain. In general, data on chemical persistence on drinking water infrastructure is available for inorganics such as arsenic and mercury, as well as select organics such as petroleum products, pesticides and rodenticides. Data specific to chemical warfare agents and pharmaceuticals was not found and data on toxins is scant. Future research suggestions focus on expanding the available chemical persistence data to other common drinking water infrastructure materials. Decontaminating agents that successfully removed persistent contamination from one infrastructure material should be used in further studies. Methods for sampling or extracting chemical agents from water infrastructure surfaces are needed. Published by Elsevier Ltd.
2011-05-30
affect chemical agents. Therefore no change in the methods for chemical or radiological decontamination would be necessary. 14. Radiation...here is the high radiation doses do affect the ability to polymerase chain reaction methods. It appears, depending on the dose and target, these...2001) Bacillus spore inactivation methods affect detection assays. Appl Environ Microbiol. 67(8): p. 3665‐70. DeCarlos, A. and Paez, E. (1991
COMPILATION OF AVAILABLE DATA ON BUILDING DECONTAMINATION ALTERNATIVES
The report presents an analysis of selected technologies that have been tested for their potential effectiveness in decontaminating a building that has been attacked using biological or chemical warfare agents, or using toxic industrial compounds. The technologies selected to be ...
Decontamination of Bacillus spores adhered to iron and ...
Journal Article This study examines the effectiveness of decontaminating Bacillus globigii spores attached to corroded iron and cement-mortar coupons with free chlorine at two pH levels, monochloramine, chlorine dioxide, ozone, peracetic acid (PAA) and acidified nitrite, followed by flushing.
Delcanale, Pietro; Montali, Chiara; Rodríguez-Amigo, Beatriz; Abbruzzetti, Stefania; Bruno, Stefano; Bianchini, Paolo; Diaspro, Alberto; Agut, Montserrat; Nonell, Santi; Viappiani, Cristiano
2016-11-16
Zinc-substituted myoglobin (ZnMb) is a naturally occurring photosensitizer that generates singlet oxygen with a high quantum yield. Using a combination of photophysical and fluorescence imaging techniques, we demonstrate the interaction of ZnMb with Gram-positive Staphylococcus aureus and Gram-negative Escherichia coli. An efficient antibacterial action against S. aureus was observed, with a reduction up to 99.9999% in the number of colony-forming units, whereas no sizable effect was detected against E. coli. Because ZnMb is known to form during the maturation of additive-free not-cooked cured ham, the use of this protein as a built-in photodynamic agent may constitute a viable method for the decontamination of these food products from Gram-positive bacteria.
Wales, Andrew; Breslin, Mark; Davies, Robert
2006-09-10
Salmonella infection of laying flocks in the UK is predominantly a problem of the persistent contamination of layer houses and associated wildlife vectors by Salmonella Enteritidis. Methods for its control and elimination include effective cleaning and disinfection of layer houses between flocks, and it is important to be able to measure the success of such decontamination. A method for the environmental detection and semi-quantitative enumeration of salmonellae was used and compared with a standard qualitative method, in 12 Salmonella-contaminated caged layer houses before and after cleaning and disinfection. The quantitative technique proved to have comparable sensitivity to the standard method, and additionally provided insights into the numerical Salmonella challenge that replacement flocks would encounter. Elimination of S. Enteritidis was not achieved in any of the premises examined although substantial reductions in the prevalence and numbers of salmonellae were demonstrated, whilst in others an increase in contamination was observed after cleaning and disinfection. Particular problems with feeders and wildlife vectors were highlighted. The use of a quantitative method assisted the identification of problem areas, such as those with a high initial bacterial load or those experiencing only a modest reduction in bacterial count following decontamination.
Methods of preventing bacterial sepsis and wound complications after liver transplantation.
Gurusamy, Kurinchi Selvan; Nagendran, Myura; Davidson, Brian R
2014-03-05
Bacterial sepsis and wound complications after liver transplantation increase mortality, morbidity, or hospital stay and are likely to increase overall transplant costs. All liver transplantation patients receive antibiotic prophylaxis. This is an update of our 2008 Cochrane systematic review on the same topic in which we identified seven randomised clinical trials. To assess the benefits and harms of different methods aimed at preventing bacterial sepsis and wound complications in people undergoing liver transplantation. We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, EMBASE, and Science Citation Index Expanded to February 2013. We included only randomised clinical trials irrespective of language or publication status. We excluded quasi-randomised and other observational studies for assessment of benefits, but not for harms. Two review authors collected the data independently. We calculated the risk ratio (RR) or mean difference (MD) with 95% confidence intervals (CI) using fixed-effect and the random-effects models based on available-case analysis. We identified only seven trials for inclusion, including 614 participants. Only one trial was of low risk of bias risk. Overall, the quality of evidence was very low. There were five comparisons in the seven trials: selective bowel decontamination versus inactive control; selective bowel decontamination versus prebiotics with probiotics; selective bowel decontamination versus prebiotics; prebiotics with probiotics versus prebiotics; and granulocyte-colony stimulating factor (G-CSF) versus control. Four trials compared selective bowel decontamination versus placebo or no treatment. In one trial, participants were randomised to selective bowel decontamination, active lactobacillus with fibres (probiotic with prebiotic), or to inactivated lactobacillus with fibres (prebiotic). In one trial, active lactobacillus with fibres (probiotic with prebiotic) was compared with inactive lactobacillus with fibres (prebiotic). In the remaining trial, different doses of G-CSF and placebo were compared. There was no trial comparing different antibiotic prophylactic regimens in people undergoing liver transplantation. Most trials included adults undergoing elective liver transplantation. There was no significant difference in proportion of people who died or required retransplantation between the intervention and control groups in any of the five comparison groups. MORTALITY There were no differences between 190 participants (three trials); 5/87 (adjusted proportion: 6.2%) in selective bowel decontamination group versus 7/103 (6.8%) in inactive control group; RR 0.91 (95% CI 0.31 to 2.72); 63 participants (one trial); 0/32 (0%) in selective bowel decontamination group versus 0/31 (0%) in prebiotics with probiotics group; RR - not estimable; 64 participants (one trial); 0/32 (0%) in selective bowel decontamination group versus 0/32 (0%) in prebiotics group; RR - not estimable; 129 participants (two trials); 0/64 (0%) in prebiotics with probiotics group versus 0/65 (0%) in prebiotics group; RR - not estimable; and 194 participants (one trial); 22/124 (17.7%) in G-CSF group versus 10/70 (14.3%) in placebo group; RR 1.24 (95% 0.62 to 2.47). RETRANSPLANTATION There were no differences between 132 participants (two trials); 4/58 (adjusted proportion: 6.9%) in selective bowel decontamination group versus 6/74 (8.1%) in inactive control group; RR 0.85 (95% CI 0.26 to 2.85); 63 participants (one trial); 1/32 (3.1%) in selective bowel decontamination group versus 0/31 (0%) in prebiotics with probiotics group; RR 2.91 (0.12 to 68.81); 64 participants (one trial); 1/32 (3.1%) in selective bowel decontamination group versus 0/32 (0%) in prebiotics group; RR 3.00 (95% CI 0.13 to 71.00); 129 participants (two trials); 0/64 (0%) in prebiotics with probiotics group versus 1/65 (1.5%) in prebiotics group; RR 0.33 (95% CI 0.01 to 7.9); and 194 participants (one trial); 10/124 (7.1%) in G-CSF group versus 5/70 (7.1%) in placebo group; RR 1.13 (95% CI 0.4 to 3.17).There was no significant difference in the graft rejections, intensive therapy unit stay, or hospital stay between the intervention and control groups in any of the comparisons. Overall, 193/611 participants (31.6%) developed infective complications. The proportion of people who developed infective complications and the number of infective complication episodes were significantly higher in the selective bowel decontamination group than in the prebiotics with probiotics group (1 study; 63 participants; 15/32 (46.9%) in selective bowel decontamination group versus 4/31 (12.9%) in prebiotics with probiotics group; RR 3.63; 95% CI 1.36 to 9.74 and 23/32 participants (0.72 infective complications per participant) in selective bowel decontamination group versus 4/31 participants (0.13 infective complications per participant) in prebiotics with probiotics group; rate ratio 5.58; 95% CI 1.94 to 16.09). There was no significant difference between the proportion of participants who developed infection and the number of infection episodes between the intervention group and control group in any of the other comparisons.No trials reported quality of life and overall serious adverse events. Currently, there is no clear evidence for any intervention offering significant benefits in the reduction of bacterial infections and wound complications in liver transplantation. Selective bowel decontamination may even increase the rate of infections compared with prebiotics with probiotics. The confidence intervals were wide and further randomised clinical trials of low risk of bias are necessary.
Method for decontamination of nickel-fluoride-coated nickel containing actinide-metal fluorides
Windt, Norman F.; Williams, Joe L.
1983-01-01
The invention is a process for decontaminating particulate nickel contaminated with actinide-metal fluorides. In one aspect, the invention comprises contacting nickel-fluoride-coated nickel with gaseous ammonia at a temperature effecting nickel-catalyzed dissociation thereof and effecting hydrogen-reduction of the nickel fluoride. The resulting nickel is heated to form a melt and a slag and to effect transfer of actinide metals from the melt into the slag. The melt and slag are then separated. In another aspect, nickel containing nickel oxide and actinide metals is contacted with ammonia at a temperature effecting nickel-catalyzed dissociation to effect conversion of the nickel oxide to the metal. The resulting nickel is then melted and separated as described. In another aspect nickel-fluoride-coated nickel containing actinide-metal fluorides is contacted with both steam and ammonia. The resulting nickel then is melted and separated as described. The invention is characterized by higher nickel recovery, efficient use of ammonia, a substantial decrease in slag formation and fuming, and a valuable increase in the service life of the furnace liners used for melting.
A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent.
Waysbort, Daniel; McGarvey, David J; Creasy, William R; Morrissey, Kevin M; Hendrickson, David M; Durst, H Dupont
2009-01-30
A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Greentrade mark, has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO(4)(-2)) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t(1/2) < or = 4 min), 1:10 for HD (t(1/2) < 2 min with molybdate), and 1:10 for GD (t(1/2) < 2 min). The vapor concentrations of GD above the dry sorbent and the sorbent with decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD.
Price, E; Weaver, G; Hoffman, P; Jones, M; Gilks, J; O’Brien, V; Ridgway, G
2015-01-01
Introduction: A variety of methods are in use for decontaminating breast pump milk collection kits and related items associated with infant feeding. This paper aims to provide best practice guidance for decontamination of this equipment at home and in hospital. It has been compiled by a joint Working Group of the Healthcare Infection Society and the Infection Prevention Society. Methods: The guidance has been informed by a search of the literature in Medline, the British Nursing Index, the Cumulative Index to Nursing & Allied Health Literature, Midwifery & Infant Care and the results of two surveys of UK neonatal units in 2002/3 and 2006, and of members of the Infection Prevention Society in 2014. Since limited good quality evidence was available from these sources much of the guidance represents good practice based on the consensus view of the Working Group. Key recommendations: Breast pump milk collection kits should not be reused by different mothers unless they have been sterilized in a Sterile Services Department between these different users. When used by the same mother, a detergent wash followed by thorough rinsing and drying after each use gives acceptable decontamination for most circumstances, as long as it is performed correctly. Additional decontamination precautions to washing, rinsing and drying may be used if indicated by local risk assessments and on advice from the departmental clinicians and Infection Prevention and Control Teams. The microbiological quality of the rinse water is an important consideration, particularly for infants on neonatal units. If bottle brushes or breast/nipple shields are used, they should be for use by one mother only. Decontamination should be by the processes used for breast pump milk collection kits. Dummies (soothers, pacifiers or comforters) needed for non-nutritive sucking by infants on neonatal units, should be for single infant use. Manufacturers should provide these dummies ready-to-use and individually packaged. They must be discarded at least every 24 hours or immediately if soiled with anything other than the baby’s saliva. No attempt should be made to decontaminate the dummies, either before or during use. Conclusion: This guidance provides practical recommendations to support the safe decontamination of breast pump milk collection kits for healthcare professionals to use and communicate to other groups such as parents and carers. PMID:28989455
Dadhwal, M; Singh, A; Prakash, O; Gupta, S K; Kumari, K; Sharma, P; Jit, S; Verma, M; Holliger, C; Lal, R
2009-02-01
To locate a high-dose point hexachlorocyclohexane (HCH)-contaminated site, to identify HCH-degrading bacteria in it and assay HCH-decontamination by biostimulation. Bacteria were isolated by serial dilution method from HCH-contaminated soil samples collected from areas near an HCH-manufacturing unit and its dumpsite in North India. After confirming the presence of indigenous HCH-degraders (seven of 24 strains), an ex situ biostimulation experiment was conducted. For this, residue levels in soil were diluted by mixing with pristine garden soil and aeration, moisture and nutrients were provided intermittently. This soil was monitored for reduction in Sigma-HCH (sum of alpha-, beta-, gamma- and delta-HCH) levels and stimulation of HCH-degraders. Experiments were conducted twice, in March-April (c. 75 microg Sigma-HCH g(-1) soil) and October-November 2006 (c. 280 microg Sigma-HCH g(-1) soil) at 26-30 degrees C. Sigma-HCH levels were reduced to <30% of the original in 24 days and <3% in 240 days in the experimental pits. Terminal restriction fragment length polymorphism analysis reflected changes in microbial community structure during the course of experiment. Our results show presence of HCH-degrading sphingomonads at a high-dose point HCH-contaminated site and presents biostimulation as an effective approach for its decontamination via aeration, addition of nutrients and moisture, of the indigenous population. The study demonstrates that biostimulation of indigenous HCH-degrading microbial population can be used for decontamination of chronically HCH-contaminated sites.
Foam and gel methods for the decontamination of metallic surfaces
Nunez, Luis; Kaminski, Michael Donald
2007-01-23
Decontamination of nuclear facilities is necessary to reduce the radiation field during normal operations and decommissioning of complex equipment. In this invention, we discuss gel and foam based diphosphonic acid (HEDPA) chemical solutions that are unique in that these solutions can be applied at room temperature; provide protection to the base metal for continued applications of the equipment; and reduce the final waste form production to one step. The HEDPA gels and foams are formulated with benign chemicals, including various solvents, such as ionic liquids and reducing and complexing agents such as hydroxamic acids, and formaldehyde sulfoxylate. Gel and foam based HEDPA processes allow for decontamination of difficult to reach surfaces that are unmanageable with traditional aqueous process methods. Also, the gel and foam components are optimized to maximize the dissolution rate and assist in the chemical transformation of the gel and foam to a stable waste form.
Decontamination of biological warfare agents by a microwave plasma torch
NASA Astrophysics Data System (ADS)
Lai, Wilson; Lai, Henry; Kuo, Spencer P.; Tarasenko, Olga; Levon, Kalle
2005-02-01
A portable arc-seeded microwave plasma torch running stably with airflow is described and applied for the decontamination of biological warfare agents. Emission spectroscopy of the plasma torch indicated that this torch produced an abundance of reactive atomic oxygen that could effectively oxidize biological agents. Bacillus cereus was chosen as a simulant of Bacillus anthracis spores for biological agent in the decontamination experiments. Decontamination was performed with the airflow rate of 0.393l/s, corresponding to a maximum concentration of atomic oxygen produced by the torch. The experimental results showed that all spores were killed in less than 8 s at 3 cm distance, 12 s at 4 cm distance, and 16 s at 5 cm distance away from the nozzle of the torch.
Davies, A; Pottage, T; Bennett, A; Walker, J
2011-03-01
The recent data for hospital-acquired infections suggest that infection rates for meticillin-resistant Staphylococcus aureus (MRSA) and Clostridium difficile are beginning to decrease. However, while there is still pressure to maintain this trend, the resistance of C. difficile spores to standard detergents continues to present a problem for many UK hospitals trying to prevent its spread or control outbreaks. Alternative disinfection technologies such as gaseous decontamination are currently being marketed to the healthcare sector as an alternative/supplement to manual disinfection, and have been shown to be effective in reducing environmental contamination. When used correctly, they offer a complementary technology to manual cleaning that increases the probability of an effective reduction in viability and provides a comparatively uniform distribution of disinfectant. Three gaseous decontamination technologies are examined for their suitability in reducing environmental contamination with C. difficile: gaseous hydrogen peroxide, chlorine dioxide and ozone. Air decontamination and UV-based technologies are also briefly described. We conclude that while there is a role to play for these new technologies in the decontamination of ward surfaces contaminated with C. difficile, the requirement for both a preclean before use and the limited 'in vivo' evidence means that extensive field trials are necessary to determine their cost-effectiveness in a healthcare setting. Copyright © 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Reactive formulations for a neutralization of toxic industrial chemicals
Tucker, Mark D [Albuqueruqe, NM; Betty, Rita G [Rio Rancho, NM
2006-10-24
Decontamination formulations for neutralization of toxic industrial chemicals, and methods of making and using same. The formulations are effective for neutralizing malathion, hydrogen cyanide, sodium cyanide, butyl isocyanate, carbon disulfide, phosgene gas, capsaicin in commercial pepper spray, chlorine gas, anhydrous ammonia gas; and may be effective at neutralizing hydrogen sulfide, sulfur dioxide, formaldehyde, ethylene oxide, methyl bromide, boron trichloride, fluorine, tetraethyl pyrophosphate, phosphorous trichloride, arsine, and tungsten hexafluoride.
Present State of CBRN Decontamination Methodologies (Stand van Zaken CBRN- Ontsmettingsmethodieken)
2007-03-01
activity and effectiveness . The oxidation of HD requires the presence of activators such as carbonate (CO 3 2-, bicarbonate (HC0 3") or molybdate (MOO 4 2...gasses), nucleophilic substitution (alkaline hydrolysis and oximes) and alternative chemical approaches. Some chemical decontaminants are effective ...are commercially available. Most enzymes are only effective against GB and GD, however, some enzymatic approaches towards destruction of VX, HD and
Offin, Douglas G; Birkin, Peter R; Leighton, Timothy G
2014-03-14
Electrochemical and high-speed imaging techniques are used to study the abilities of ultrasonically-activated bubbles to clean out micropores. Cylindrical pores with dimensions (diameter × depth) of 500 μm × 400 μm (aspect ratio 0.8), 125 μm × 350 μm (aspect ratio 2.8) and 50 μm × 200 μm (aspect ratio 4.0) are fabricated in glass substrates. Each pore is contaminated by filling it with an electrochemically inactive blocking organic material (thickened methyl salicylate) before the substrate is placed in a solution containing an electroactive species (Fe(CN)6(3-)). An electrode is fabricated at the base of each pore and the Faradaic current is used to monitor the decontamination as a function of time. For the largest pore, decontamination driven by ultrasound (generated by a horn type transducer) and bulk fluid flow are compared. It is shown that ultrasound is much more effective than flow alone, and that bulk fluid flow at the rates used cannot decontaminate the pore completely, but that ultrasound can. In the case of the 125 μm pore, high-speed imaging is used to elucidate the cleaning mechanisms involved in ultrasonic decontamination and reveals that acoustic bubble entrapment is a key feature. The smallest pore is used to explore the limits of decontamination and it is found that ultrasound is still effective at this size under the conditions employed.
Vehicle effects on human stratum corneum absorption and skin penetration.
Zhang, Alissa; Jung, Eui-Chang; Zhu, Hanjiang; Zou, Ying; Hui, Xiaoying; Maibach, Howard
2017-05-01
This study evaluated the effects of three vehicles-ethanol (EtOH), isopropyl alcohol (IPA), and isopropyl myristate (IPM)-on stratum corneum (SC) absorption and diffusion of the [ 14 C]-model compounds benzoic acid and butenafine hydrochloride to better understand the transport pathways of chemicals passing through and resident in SC. Following application of topical formulations to human dermatomed skin for 30 min, penetration flux was observed for 24 h post dosing, using an in vitro flow-through skin diffusion system. Skin absorption and penetration was compared to the chemical-SC (intact, delipidized, or SC lipid film) binding levels. A significant vehicle effect was observed for chemical skin penetration and SC absorption. IPA resulted in the greatest levels of intact SC/SC lipid absorption, skin penetration, and total skin absorption/penetration of benzoic acid, followed by IPM and EtOH, respectively. For intact SC absorption and total skin absorption/penetration of butenafine, the vehicle that demonstrated the highest level of sorption/penetration was EtOH, followed by IPA and IPM, respectively. The percent doses of butenafine that were absorbed in SC lipid film and penetrated through skin in 24 h were greatest for IPA, followed by EtOH and IPM, respectively. The vehicle effect was consistent between intact SC absorption and total chemical skin absorption and penetration, as well as SC lipid absorption and chemical penetration through skin, suggesting intercellular transport as a main pathway of skin penetration for model chemicals. These results suggest the potential to predict vehicle effects on skin permeability with simple SC absorption assays. As decontamination was applied 30 min after chemical exposure, significant vehicle effects on chemical SC partitioning and percutaneous penetration also suggest that skin decontamination efficiency is vehicle dependent, and an effective decontamination method should act on chemical solutes in the lipid domain.
2006-11-01
EFFECTIVENESS OF HALOGEN-BASED DISINFECTANTS AGAINST Acinetobacter baumannii: WOUND CARE AND ENVIROMENTAL DECONTAMINATION James...a standard E. coli comparator, in a novel bacterial culture system that incorporated a three log range of organic growth media concentrations. We...report the highest dilutions of stock disinfectant able to inhibit replication or kill the bacteria , denoted as the maximum inhibitory dilution
Kotsakis, Georgios A; Lan, Caixia; Barbosa, Joao; Lill, Krista; Chen, Ruoqiong; Rudney, Joel; Aparicio, Conrado
2016-07-01
Chemotherapeutic agents (ChAs) are considered an integral part of current treatment protocols for the decontamination of titanium implants with peri-implantitis, based on their antimicrobial effect. Despite the proven antimicrobial effect of ChAs on titanium-bound biofilms, previous studies have elucidated an unexpected disassociation between bacterial reduction and biologically acceptable treatment outcomes. In this study, the authors hypothesize that ChAs residues alter titanium physicochemistry and thus compromise cellular response to decontaminated surfaces. Grit-blasted acid-etched titanium disks were contaminated with multispecies microcosm biofilms grown from in vivo peri-implant plaque samples. To simulate implant decontamination, the contaminated disks were burnished with 0.12% chlorhexidine, 20% citric acid, 24% EDTA/1.5% NaOCl, or sterile saline and assessed surface physicochemical properties. Sterile untreated surfaces were the controls. The biologic effects of decontamination were assessed via cell proliferation and differentiation assays. Bacterial counts after decontamination confirmed that the ChAs were antimicrobial. X-ray photoelectron spectroscopy invariably detected elemental contaminants associated with each ChA molecule or salt that significantly altered wettability compared with controls. Notably, all surfaces with ChA residues showed some cytotoxic effect compared with controls (P <0.05). Increased cell counts were consistently found in the saline-treated group compared with chlorhexidine (P = 0.03). Interestingly, no association was found between antimicrobial effect and cell counts (P >0.05). ChA-specific residues left on the titanium surfaces altered titanium physical properties and adversely affected the osteoblastic response irrespective of their observed antimicrobial effect. Chlorhexidine may compromise the biocompatibility of titanium surfaces, and its use is not recommended to detoxify implants. Sterile saline, citric acid, and NaOCl-EDTA may be proposed for use in the treatment of peri-implantitis. Contrary to previous studies that recommended the selection of ChAs for the decontamination of titanium implants according to their antimicrobial effects, the present study demonstrated that the restoration of the biocompatibility of contaminated titanium surfaces is also contingent on the preservation of titanium material properties.
Post-Decontamination Vapor Sampling and Analytical Test Methods
2015-08-12
construction materials (e.g., acrylic, stainless steel , glass, etc.) for containing the chemical contaminants, coupons, coupon holders, and decontaminant(s...made of inert materials, e.g., stainless steel , T6061 aluminum, or equivalent. The construction material may be treated to further minimize...include glove ports. The chamber may have certified fume hoods for the containment of toxic chemicals. All exhaust air must be filtered to
Methods for Decontamination of a Bipropellant Propulsion System
NASA Technical Reports Server (NTRS)
McClure, Mark B.; Greene, Benjamin
2012-01-01
Most propulsion systems are designed to be filled and flown, draining can be done but decontamination may be difficult. Transport of these systems may be difficult as well because flight weight vessels are not designed around DOT or UN shipping requirements. Repairs, failure analysis work or post firing inspections may be difficult or impossible to perform due to the hazards of residual propellants being present.
Tayel, Ahmed A; El-Sedfy, Mahmoud A; Ibrahim, Ahmed I; Moussa, Shaaban H
2018-04-21
Egg contamination with microbial pathogens is an enduring worldwide concern. Natural products are frequently recommended as ideal alternatives to substitute synthetic and chemical antimicrobials. Oak galls (Quercus infectoria) are aberrant growths on oak trees that have many medicinal and pharmaceutical applications. Q. infectoria extract (QIE) antimicrobial action was assessed against many microbial species, and used for eggshell decontamination. QIE antimicrobial activity was evidenced against Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, Salmonella Typhimurium and Candida albicans, using different assay methods. Disinfection of eggshell microbial contamination, by immersion in 1% QIE solution, sharply reduced total colony count, yeasts and molds, Enterobacteriaceae. E. coli and S. aureus were completely inhibited after 60min of immersion in QIE. QIE biochemical analysis revealed elevated contents of phenolic and flavonoid compounds. The captured micrographs of S. aureus cells treated with QIE showed strong alterations in cell morphology; cells were entirely lysed and ruptured after 6h of treatment. QIE can be recommended as an effective and natural disinfectant for decontaminating eggshells from pathogenic microorganisms. Copyright © 2018 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
NASA Astrophysics Data System (ADS)
Herrmann, H. W.; Henins, I.; Park, J.; Selwyn, G. S.
1999-05-01
The atmospheric pressure plasma jet (APPJ) [A. Schütze et al., IEEE Trans. Plasma Sci. 26, 1685 (1998)] is a nonthermal, high pressure, uniform glow plasma discharge that produces a high velocity effluent stream of highly reactive chemical species. The discharge operates on a feedstock gas (e.g., He/O2/H2O), which flows between an outer, grounded, cylindrical electrode and an inner, coaxial electrode powered at 13.56 MHz rf. While passing through the plasma, the feedgas becomes excited, dissociated or ionized by electron impact. Once the gas exits the discharge volume, ions and electrons are rapidly lost by recombination, but the fast-flowing effluent still contains neutral metastable species (e.g., O2*, He*) and radicals (e.g., O, OH). This reactive effluent has been shown to be an effective neutralizer of surrogates for anthrax spores and mustard blister agent. Unlike conventional wet decontamination methods, the plasma effluent does not cause corrosion and it does not destroy wiring, electronics, or most plastics, making it highly suitable for decontamination of sensitive equipment and interior spaces. Furthermore, the reactive species in the effluent rapidly degrade into harmless products leaving no lingering residue or harmful by-products.
Rogers, J V; Sabourin, C L K; Choi, Y W; Richter, W R; Rudnicki, D C; Riggs, K B; Taylor, M L; Chang, J
2005-01-01
To evaluate the decontamination of Bacillus anthracis, Bacillus subtilis, and Geobacillus stearothermophilus spores on indoor surface materials using hydrogen peroxide gas. Bacillus anthracis, B. subtilis, and G. stearothermophilus spores were dried on seven types of indoor surfaces and exposed to > or =1000 ppm hydrogen peroxide gas for 20 min. Hydrogen peroxide exposure significantly decreased viable B. anthracis, B. subtilis, and G. stearothermophilus spores on all test materials except G. stearothermophilus on industrial carpet. Significant differences were observed when comparing the reduction in viable spores of B. anthracis with both surrogates. The effectiveness of gaseous hydrogen peroxide on the growth of biological indicators and spore strips was evaluated in parallel as a qualitative assessment of decontamination. At 1 and 7 days postexposure, decontaminated biological indicators and spore strips exhibited no growth, while the nondecontaminated samples displayed growth. Significant differences in decontamination efficacy of hydrogen peroxide gas on porous and nonporous surfaces were observed when comparing the mean log reduction in B. anthracis spores with B. subtilis and G. stearothermophilus spores. These results provide comparative information for the decontamination of B. anthracis spores with surrogates on indoor surfaces using hydrogen peroxide gas.
Szabo, Jeff; Minamyer, Scott
2014-11-01
This report summarizes the current state of knowledge on the persistence of biological agents on drinking water infrastructure (such as pipes) along with information on decontamination should persistence occur. Decontamination options for drinking water infrastructure have been explored for some biological agents, but data gaps remain. Data on bacterial spore persistence on common water infrastructure materials such as iron and cement-mortar lined iron show that spores can be persistent for weeks after contamination. Decontamination data show that common disinfectants such as free chlorine have limited effectiveness. Decontamination results with germinant and alternate disinfectants such as chlorine dioxide are more promising. Persistence and decontamination data were collected on vegetative bacteria, such as coliforms, Legionella and Salmonella. Vegetative bacteria are less persistent than spores and more susceptible to disinfection, but the surfaces and water quality conditions in many studies were only marginally related to drinking water systems. However, results of real-world case studies on accidental contamination of water systems with E. coli and Salmonella contamination show that flushing and chlorination can help return a water system to service. Some viral persistence data were found, but decontamination data were lacking. Future research suggestions focus on expanding the available biological persistence data to other common infrastructure materials. Further exploration of non-traditional drinking water disinfectants is recommended for future studies. Published by Elsevier Ltd.
Destruction of Spores on Building Decontamination Residue in a Commercial Autoclave▿
Lemieux, P.; Sieber, R.; Osborne, A.; Woodard, A.
2006-01-01
The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 106 spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in2 and 275°F and 75 min at 45 lb/in2 and 292°F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in2 and 275°F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process. PMID:17012597
Mikler, J; Tenn, C; Worek, F; Reiter, G; Thiermann, H; Garrett, M; Bohnert, S; Sawyer, T W
2011-09-25
The chemical weapon nerve agent known as Russian VX (VR) is a potent organophosphorus (OP) compound that is much less studied than its VX analogue with respect to toxicity, as well as to the effectiveness of several known countermeasures against it. An anaesthetized domestic swine model was utilized to assess several approaches in mitigating its toxicity, including the utility of cooling VR treated skin to increase the therapeutic window for treatment. The 6h LD₅₀ for VR topically applied on the ear was 100 μg/kg. Treatment of VR exposed animals (5 × LD₅₀) with pralidoxime (2PAM) very poorly regenerated inhibited blood cholinesterase activity, but was partially effective in preventing signs of OP poisoning and increasing survival. In contrast, treatment with the Hagedorn oxime HI-6 reactivated cholinesterase, eliminated all signs of poisoning and prevented death. Decontamination with the Reactive Skin Decontaminant Lotion (RSDL) 15 min after VR exposure was completely effective in preventing death. Cooling of the VR exposure sites for 2 or 6h prevented signs of OP poisoning and death during the cooling period. However, these animals died very quickly after the cessation of cooling, unless they were treated with oxime or decontaminated with RSDL. Blood analyses showed that cooling of agent exposure sites delayed the entry of VR into the bloodstream. Medical treatment with HI-6 and to a lesser extent 2PAM, or decontamination with RSDL are effective in protecting against the toxic effects of cutaneous exposure to VR. Immobilizing this agent (and related compounds) within the dermal reservoir by cooling the exposure sites, dramatically increases the therapeutic window in which these medical countermeasures are effective. Crown Copyright © 2011. Published by Elsevier Ireland Ltd. All rights reserved.
Destruction of spores on building decontamination residue in a commercial autoclave.
Lemieux, P; Sieber, R; Osborne, A; Woodard, A
2006-12-01
The U.S. Environmental Protection Agency conducted an experiment to evaluate the effectiveness of a commercial autoclave for treating simulated building decontamination residue (BDR). The BDR was intended to simulate porous materials removed from a building deliberately contaminated with biological agents such as Bacillus anthracis (anthrax) in a terrorist attack. The purpose of the tests was to assess whether the standard operating procedure for a commercial autoclave provided sufficiently robust conditions to adequately destroy bacterial spores bound to the BDR. In this study we investigated the effects of several variables related to autoclaving BDR, including time, temperature, pressure, item type, moisture content, packing density, packing orientation, autoclave bag integrity, and autoclave process sequence. The test team created simulated BDR from wallboard, ceiling tiles, carpet, and upholstered furniture, and embedded in the BDR were Geobacillus stearothermophilus biological indicator (BI) strips containing 10(6) spores and thermocouples to obtain time and temperature profile data associated with each BI strip. The results indicated that a single standard autoclave cycle did not effectively decontaminate the BDR. Autoclave cycles consisting of 120 min at 31.5 lb/in2 and 275 degrees F and 75 min at 45 lb/in2 and 292 degrees F effectively decontaminated the BDR material. Two sequential standard autoclave cycles consisting of 40 min at 31.5 lb/in2 and 275 degrees F proved to be particularly effective, probably because the second cycle's evacuation step pulled the condensed water out of the pores of the materials, allowing better steam penetration. The results also indicated that the packing density and material type of the BDR in the autoclave could have a significant impact on the effectiveness of the decontamination process.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Manthei, J.H.; Heitkamp, D.H.; Buettner, L.C.
1992-07-01
The acute percutaneous (bare skin) LD50 was determined for EA 2192 in the rabbit. Also established were the effective doses (ED50s) for the major toxic signs observed. Dermal, Department of Transportation (DOT), tests with rabbits indicated that VX/HTH decontaminated waste is a Class B poison after being aged only 24 hr following initiation of the decontamination procedure. The same reaction, when allowed to age through about 2 half-lives (28-30 days), was no longer a Class B poison and was nonhazardous by Code of Maryland Regulations (COMAR) toxicity criteria. The DOT tests with OXONE decontaminated/neutralized VX showed this solution to bemore » less than a Class B poison by all three routes of administration (rat oral, rat inhalation, and rabbit dermal) after only 24-hr aging and a nonhazardous material by COMAR toxicity criteria.... vx, Rat, Half-life, ED50, EA 2192, Rabbit, COMAR, Decontaminated/Neutralized, HTH, OXONE, LD50.« less
A novel copper-hydrogen peroxide formulation for prion decontamination.
Solassol, Jerome; Pastore, Manuela; Crozet, Carole; Perrier, Veronique; Lehmann, Sylvain
2006-09-15
With the appearance of variant Creutzfeldt-Jakob disease (CJD) and the detection of infectious prions in the peripheral organs of persons with sporadic CJD, the development of decontamination methods that are compatible with medical equipment has become a major issue. Here, we show that a formulation of copper metal ions in combination with hydrogen peroxide dramatically reduces the level of prion protein (PrP)(Sc) (the scrapie isoform of PrP) present in homogenates of samples from prion-infected brains, including brain samples from humans with CJD. An animal bioassay confirmed the reduction in prion infectivity, indicating that this novel Cu(2+)-H(2)O(2) formulation has great potential for prion decontamination.
Decontamination of poultry feed from ochratoxin A by UV and sunlight radiations.
Ameer Sumbal, Gul; Hussain Shar, Zahid; Hussain Sherazi, Syed Tufail; Sirajuddin; Nizamani, Shafi Muhammad; Mahesar, Safaraz Ahmed
2016-06-01
Mycotoxin-contaminated feed is very dangerous for the growth and even life of poultry. The objective of the current study was to investigate the efficacy of ultra-violet irradiation for decontamination of ochratoxin A (OTA) in spiked and naturally contaminated poultry feed samples. Spiked and naturally contaminated feed samples were irradiated with ultra-violet light (UV) at distance of 25 cm over the feed samples. In vitro, the effect of UV intensity (0.1 mW cm(-2) at 254 nm UV-C) on different types of poultry feeds contaminated with OTA was evaluated. The same samples were also irradiated with sunlight and analysed for OTA by an indirect enzyme linked immunosorbent assay method. Poultry feed samples containing 500 µg kg(-1) were 100% decontaminated in 180 min with UV radiation while OTA was decreased to 70-95 µg kg(-1) using the same poultry feed samples after 8 h sunlight irradiation. Therefore, UV light was found to be more effective. Only 1 h of UV irradiation was found to be sufficient to bring the OTA level to the maximum regulatory limit suggested for poultry feeds (100 µg kg(-1) ), while 8 h were needed to obtain this level using sunlight radiations. The proposed approach is a viable option to reduce the level of OTA in contaminated poultry feeds. © 2015 Society of Chemical Industry. © 2015 Society of Chemical Industry.
1985-03-01
gallons for Building 2. -... The system must be capable of wit standing caustic corrosion. • Either stainless steel or lined mild steel may be used. As...assumed that spent charcoal could be disposed in some safe manner arid would be re- placed as used. Additional costs were in luded for sampling and analysis...decontamination of all three explosives could be effected by further sequential treatment of the spent explosives decontami- nation solutions with acidic ferrous
A decontamination study of simulated chemical and biological agents
NASA Astrophysics Data System (ADS)
Uhm, Han S.; Lee, Han Y.; Hong, Yong C.; Shin, Dong H.; Park, Yun H.; Hong, Yi F.; Lee, Chong K.
2007-07-01
A comprehensive decontamination scheme of the chemical and biological agents, including airborne agents and surface contaminating agents, is presented. When a chemical and biological attack occurs, it is critical to decontaminate facilities or equipments to an acceptable level in a very short time. The plasma flame presented here may provide a rapid and effective elimination of toxic substances in the interior air in isolated spaces. As an example, a reaction chamber, with the dimensions of a 22cm diameter and 30cm length, purifies air with an airflow rate of 5000l/min contaminated with toluene, the simulated chemical agent, and soot from a diesel engine, the simulated aerosol for biological agents. Although the airborne agents in an isolated space are eliminated to an acceptable level by the plasma flame, the decontamination of the chemical and biological agents cannot be completed without cleaning surfaces of the facilities. A simulated sterilization study of micro-organisms was carried out using the electrolyzed ozone water. The electrolyzed ozone water very effectively kills endospores of Bacillus atrophaeus (ATCC 9372) within 3min. The electrolyzed ozone water also kills the vegetative micro-organisms, fungi, and virus. The electrolyzed ozone water, after the decontamination process, disintegrates into ordinary water and oxygen without any trace of harmful materials to the environment.
Calfee, M W; Wendling, M
2015-11-01
Five commercially available liquid antimicrobials were evaluated for their ability to decontaminate common environmental surface materials, contaminated with Burkholderia pseudomallei, using a spray-based disinfectant delivery procedure. Tests were conducted at both an ambient temperature (c. 20°C) and a lower temperature (c. 12°C) condition. Nonporous materials (glass and aluminium) were more easily decontaminated than porous materials (wood, concrete and carpet). Citric acid (1%) demonstrated poor efficacy in all test conditions. Bleach (pH-adjusted), ethanol (70%), quaternary ammonium and PineSol®, demonstrated high (>6 log10 reduction) efficacies on glass and aluminium at both temperatures, but achieved varying results for wood, carpet and concrete. Temperature had minimal effect on decontamination efficacy during these tests. Much of the antimicrobial efficacy data for pathogenic micro-organisms are generated with testing that utilizes hard nonporous surface materials. These data are not directly translatable for decontaminant selection following an incident whereby complex and porous environmental surfaces are contaminated. This study presents efficacy data for spray-applied antimicrobial liquids, when used to decontaminate common environmental surfaces contaminated with Burkholderia pseudomallei. These data can help responders develop effective remediation strategies following an environmental contamination incident involving B. pseudomallei. Published 2015. This article is a U.S. Government work and is in the public domain in the USA.
Electrolytic decontamination of conductive materials for hazardous waste management
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wedman, D.E.; Martinez, H.E.; Nelson, T.O.
1996-12-31
Electrolytic removal of plutonium and americium from stainless steel and uranium surfaces has been demonstrated. Preliminary experiments were performed on the electrochemically based decontamination of type 304L stainless steel in sodium nitrate solutions to better understand the metal removal effects of varying cur-rent density, pH, and nitrate concentration parameters. Material removal rates and changes in surface morphology under these varying conditions are reported. Experimental results indicate that an electropolishing step before contamination removes surface roughness, thereby simplifying later electrolytic decontamination. Sodium nitrate based electrolytic decontamination produced the most uniform stripping of material at low to intermediate pH and at sodiummore » nitrate concentrations of 200 g L{sup -1} and higher. Stirring was also observed to increase the uniformity of the stripping process.« less
Spiandore, Marie; Piram, Anne; Lacoste, Alexandre; Prevost, Philippe; Maloni, Pascal; Torre, Franck; Asia, Laurence; Josse, Denis; Doumenq, Pierre
2017-04-01
Chemical warfare agents are an actual threat and victims' decontamination is a main concern when mass exposure occurs. Skin decontamination with current protocols has been widely documented, as well as surface decontamination. However, considering hair ability to trap chemicals in vapour phase, we investigated hair decontamination after exposure to sulphur mustard simulants methyl salicylate and 2-chloroethyl ethyl sulphide. Four decontamination protocols were tested on hair, combining showering and emergency decontamination (use of Fuller's earth or Reactive Skin Decontamination Lotion RSDL ® ). Both simulants were recovered from hair after treatment, but contents were significantly reduced (42-85% content allowance). Showering alone was the least efficient protocol. Concerning 2-chloroethyl ethyl sulphide, protocols did not display significant differences in decontamination efficacy. For MeS, use of emergency decontaminants significantly increased showering efficacy (10-20% rise), underlining their usefulness before thorough decontamination. Our results highlighted the need to extensively decontaminate hair after chemical exposure. Residual amounts after decontamination are challenging, as their release from hair could lead to health issues. Copyright © 2016. Published by Elsevier B.V.
NASA Astrophysics Data System (ADS)
Enaki, N.; Paslari, T.; Turcan, M.; Bazgan, S.; Ristoscu, C.; Mihailescu, I. N.
2018-06-01
We propose novel optical methods for prevention, treatment and diagnosis of infections by pathogens using metamaterials with various geometries consisting of microspheres (i.e. photonic crystals, photonic molecules) and optical fibers structures. Around the adjacent elements of metamaterials appear the evanescent zones of propagated pulsed light radiation overlapping each other. This effect gives us the possibility to significantly increase the decontamination volume especially in non-transparent media. The parking geometries of microspheres and optical fibers ensure the efficient contact zone between the pulsed light radiation with contaminated materials (gases, liquids, tissues, implant surfaces). The penetration depth of evanescent field in contaminated materials can achieve values comparable with pathogens dimensions. We propose an attractive antimicrobial strategy using combined action of ultrashort pulses with different frequencies and pulse duration to achieve the selective decontamination of microorganisms with minimal effects on the components of human cells and tissues. We take into consideration the intrinsic symmetries of microorganisms protein structures (inclusive virus capsids) and their possible resonant excitation in double frequencies induced Raman scattering. The development of nonlinear models of the excitation of vibration modes of biomolecules of viruses and bacteria are revised taking into consideration the multi-mode aspects of interaction of pulsed light with excited biomolecules of pathogens. This method opens new possibilities in decontamination and diagnosis of the new collective processes, which can take place in viruses, bacteria, or other cellular structures under the action of external light pulses. Exponential distribution of radiation in evanescent zone gives us the possibility to capture and trap the viruses and bacteria along the optical fibers or/and microsphere surfaces.
Decontamination and Disposal Methods for Chemical Agents - A Literature Survey
1982-11-01
aqueous copper (I) ammonia complex to give a red copper (1) acetylide precipitate. The precipitate was determined either iodometricaily (sensitivity of I...ppm in decontamination solution) or colorintrically by a copper (11) ammonia complex (12 ppm). Lewisite was also assayed by gas liquid chromatography...to ammonia (then degraded to nitrogen) and carbonate ion. The latter reaction is relatively slow. The reaction may thus be con- sidered to consist of
Decontamination effect of milling by a jet mill on bacteria in rice flour.
Sotome, Itaru; Nei, Daisuke; Tsuda, Masuko; Mohammed, Sharif Hossen; Takenaka, Makiko; Okadome, Hiroshi; Isobe, Seiichiro
2011-06-01
The decontamination effect of milling by a jet mill was investigated by counting the number of bacteria in brown and white rice flour with mean particle diameters of 3, 20, and 40µm prepared by the jet mill. In the jet mill, the particles are crushed and reduced in size by the mechanical impact caused by their collision. Although the brown and white rice grains were contaminated with approximately 10(6) and 10(5) CFU/g bacteria, the microbial load of the rice flour decreased as the mean particle diameter decreased, ultimately decreasing to approximately 104 and 103 CFU/g in the brown and white rice flour. The temperature and pressure changes of the sample were not considered to have an effect on reducing the bacterial count during the milling. Hence, it was thought that the rice flour was decontaminated by other effects.
Assessment of microwave-based clinical waste decontamination unit.
Hoffman, P N; Hanley, M J
1994-12-01
A clinical waste decontamination unit that used microwave-generated heat was assessed for operator safety and efficacy. Tests with loads artificially contaminated with aerosol-forming particles showed that no particles were detected outside the machine provided the seals and covers were correctly seated. Thermometric measurement of a self-generated steam decontamination cycle was used to determine the parameters needed to ensure heat disinfection of the waste reception hopper, prior to entry for maintenance or repair. Bacterial and thermometric test pieces were passed through the machine within a full load of clinical waste. These test pieces, designed to represent a worst case situation, were enclosed in aluminium foil to shield them from direct microwave energy. None of the 100 bacterial test pieces yielded growth on culture and all 100 thermal test pieces achieved temperatures in excess of 99 degrees C during their passage through the decontamination unit. It was concluded that this method may be used to render safe the bulk of of ward-generated clinical waste.
McGann, Christopher L; Daniels, Grant C; Giles, Spencer L; Balow, Robert B; Miranda-Zayas, Jorge L; Lundin, Jeffrey G; Wynne, James H
2018-06-01
The threat of chemical warfare agents (CWA) compels research into novel self-decontaminating materials (SDM) for the continued safety of first-responders, civilians, and active service personnel. The capacity to actively detoxify, as opposed to merely sequester, offending agents under typical environmental conditions defines the added value of SDMs in comparison to traditional adsorptive materials. Porous polymers, synthesized via the high internal phase emulsion (HIPE) templating, provide a facile fabrication method for materials with permeable open cellular structures that may serve in air filtration applications. PolyHIPEs comprising polydicyclopentadiene (polyDCPD) networks form stable hydroperoxide species following activation in air under ambient conditions. The hydroperoxide-containing polyDCPD materials react quickly with CWA simulants, Demeton-S and 2-chloroethyl ethyl sulfide, forming oxidation products as confirmed via gas chromatography mass spectrometry. The simplicity of the detoxification chemistry paired with the porous foam form factor presents an exciting opportunity for the development of self-decontaminating filter media. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
[Decontamination of chemical warfare agents by photocatalysis].
Hirakawa, Tsutomu; Mera, Nobuaki; Sano, Taizo; Negishi, Nobuaki; Takeuchi, Koji
2009-01-01
Photocatalysis has been widely applied to solar-energy conversion and environmental purification. Photocatalyst, typically titanium dioxide (TiO(2)), produces active oxygen species under irradiation of ultraviolet light, and can decompose not only conventional pollutants but also different types of hazardous substances at mild conditions. We have recently started the study of photocatalytic decontamination of chemical warfare agents (CWAs) under collaboration with the National Research Institute of Police Science. This article reviews environmental applications of semiconductor photocatalysis, decontamination methods for CWAs, and previous photocatalytic studies applied to CWA degradation, together with some of our results obtained with CWAs and their simulant compounds. The data indicate that photocatalysis, which may not always give a striking power, certainly helps detoxification of such hazardous compounds. Unfortunately, there are not enough data obtained with real CWAs due to the difficulty in handling. We will add more scientific data using CWAs in the near future to develop useful decontamination systems that can reduce the damage caused by possible terrorism.
Browns Ferry Nuclear Plant Unit 2: Control rod drive scram discharge headers decontamination effort
DOE Office of Scientific and Technical Information (OSTI.GOV)
Traynor, J.C.
1983-08-01
The control rod drive (CRD) scram discharge headers were decontaminated during the Browns Ferry unit 2, cycle 4 refueling outage (August 2-5, 1982). Hydrolasing (high-pressure water blasting) was used as the method of decontamination to remove fixed and loose radioactive contaminants from the headers. It was found that hydrolasing of the west scram discharge headers resulted in approximate maximum and average decontamination factors (DFs) on contact of 13 and 5, respectively. For the east scram discharge headers, hydrolasing resulted in a maximum and average DF on contact of approximately 3. The maximum and average DFs on contact for the individualmore » headers ranged from 1 to 33 and 1 to 10, respectively, while the walkway (head-level) DFs were in the range of 3 to 4. Higher DFs were impeded by inadequate drainage and backwashing of fluid. This led to increased radiation levels in some areas and recontamination of adjacent headers.« less
Physico-Chemical Dynamics of Nanoparticle Formation during Laser Decontamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, M.D.
2005-06-01
Laser-ablation based decontamination is a new and effective approach for simultaneous removal and characterization of contaminants from surfaces (e.g., building interior and exterior walls, ground floors, etc.). The scientific objectives of this research are to: (1) characterize particulate matter generated during the laser-ablation based decontamination, (2) develop a technique for simultaneous cleaning and spectroscopic verification, and (3) develop an empirical model for predicting particle generation for the size range from 10 nm to tens of micrometers. This research project provides fundamental data obtained through a systematic study on the particle generation mechanism, and also provides a working model for predictionmore » of particle generation such that an effective operational strategy can be devised to facilitate worker protection.« less
Saegusa, J; Kurikami, H; Yasuda, R; Kurihara, K; Arai, S; Kuroki, R; Matsuhashi, S; Ozawa, T; Goto, H; Takano, T; Mitamura, H; Nagano, T; Naganawa, H; Yoshida, Z; Funaki, H; Tokizawa, T; Nakayama, S
2013-03-01
Because of radioactive fallout resulting from the Fukushima Daiichi Nuclear Power Plant (NPP) accident, water discharge from many outdoor swimming pools in Fukushima was suspended out of concern that radiocesium in the pool water would flow into farmlands. The Japan Atomic Energy Agency has reviewed the existing flocculation method for decontaminating pool water and established a practical decontamination method by demonstrating the process at eight pools in Fukushima. In this method, zeolite powder and a flocculant are used for capturing radiocesium present in pool water. The supernatant is discharged if the radiocesium concentration is less than the targeted level. The radioactive residue is collected and stored in a temporary storage space. Radioactivity concentration in water is measured with a NaI(Tl) or Ge detector installed near the pool. The demonstration results showed that the pool water in which the radiocesium concentration was more than a few hundred Bq L was readily purified by the method, and the radiocesium concentration was reduced to less than 100 Bq L. The ambient dose rates around the temporary storage space were slightly elevated; however, the total increase was up to 30% of the background dose rates when the residue was shielded with sandbags.
Luo, Jie; Cai, Limei; Qi, Shihua; Wu, Jian; Sophie Gu, Xiaowen
2017-12-15
Multiple techniques for soil decontamination were combined to enhance the phytoremediation efficiency of Eucalyptus globulese and alleviate the corresponding environmental risks. The approach constituted of chelating agent using, electrokinetic remediation, plant hormone foliar application and phytoremediation was designed to remediate multi-metal contaminated soils from a notorious e-waste recycling town. The decontamination ability of E. globulese increased from 1.35, 58.47 and 119.18 mg per plant for Cd, Pb and Cu in planting controls to 7.57, 198.68 and 174.34 mg per plant in individual EDTA treatments, respectively, but simultaneously, 0.9-11.5 times more metals leached from chelator treatments relative to controls. Low (2 V) and moderate (4 V) voltage electric fields provoked the growth of the species while high voltage (10 V) had an opposite effect and metal concentrations of the plants elevated with the increment of voltage. Volumes of the leachate decreased from 1224 to 134 mL with voltage increasing from 0 to 10 V due to electroosmosis and electrolysis. Comparing with individual phytoremediation, foliar cytokinin treatments produced 56% more biomass and intercepted 2.5 times more leachate attributed to the enhanced transpiration rate. The synergistic combination of the individuals resulted in the most biomass production and metal accumulation of the species under the stress condition relative to other methods. Time required for the multi-technique approach to decontaminate Cd, Pb and Cu from soil was 2.1-10.4 times less than individual chelator addition, electric field application or plant hormone utilization. It's especially important that nearly no leachate (60 mL in total) was collected from the multi-technique system. This approach is a suitable method to remediate metal polluted site considering its decontamination efficiency and associated environmental negligible risk. Copyright © 2017 Elsevier Ltd. All rights reserved.
Kit systems for granulated decontamination formulations
Tucker, Mark D.
2010-07-06
A decontamination formulation and method of making that neutralizes the adverse health effects of both chemical and biological compounds, especially chemical warfare (CW) and biological warfare (BW) agents, and toxic industrial chemicals. The formulation provides solubilizing compounds that serve to effectively render the chemical and biological compounds, particularly CW and BW compounds, susceptible to attack, and at least one reactive compound that serves to attack (and detoxify or kill) the compound. The formulation includes at least one solubilizing agent, a reactive compound, a sorbent additive, and water. A highly adsorbent sorbent additive (e.g., amorphous silica, sorbitol, mannitol, etc.) is used to "dry out" one or more liquid ingredients into a dry, free-flowing powder that has an extended shelf life, and is more convenient to handle and mix in the field. The formulation can be pre-mixed and pre-packaged as a multi-part kit system, where one or more of the parts are packaged in a powdered, granulated form for ease of handling and mixing in the field.
Tsubokura, Masaharu; Murakami, Michio; Nomura, Shuhei; Morita, Tomohiro; Nishikawa, Yoshitaka; Leppold, Claire; Kato, Shigeaki; Kami, Masahiro
2017-01-01
After the 2011 Fukushima Daiichi nuclear power plant accident, little information has been available on individual doses from external exposure among residents living in radioactively contaminated areas near the nuclear plant; in the present study we evaluated yearly changes in the doses from external exposure after the accident and the effects of decontamination on external exposure. This study considered all children less than 16 years of age in Soma City, Fukushima who participated in annual voluntary external exposure screening programs during the five years after the accident (n = 5,363). In total, 14,405 screening results were collected. The median participant age was eight years. The geometric mean levels of annual additional doses from external exposure attributable to the Fukushima accident, decreased each year: 0.60 mSv (range: not detectable (ND)-4.29 mSv), 0.37 mSv (range: ND-3.61 mSv), 0.22 mSv (range: ND-1.44 mSv), 0.20 mSv (range: ND-1.87 mSv), and 0.17 mSv (range: ND-0.85 mSv) in 2011, 2012, 2013, 2014, and 2015, respectively. The proportion of residents with annual additional doses from external exposure of more than 1 mSv dropped from 15.6% in 2011 to zero in 2015. Doses from external exposure decreased more rapidly than those estimated from only physical decay, even in areas without decontamination (which were halved in 395 days from November 15, 2011), presumably due to the weathering effects. While the ratios of geometric mean doses immediately after decontamination to before were slightly lower than those during the same time in areas without decontamination, annual additional doses reduced by decontamination were small (0.04-0.24 mSv in the year of immediately after decontamination was completed). The results of this study showed that the levels of external exposure among Soma residents less than 16 years of age decreased during the five years after the Fukushima Daiichi nuclear power plant accident. Decontamination had only limited and temporal effects on reducing individual external doses.
Hall, Alan H; Cavallini, Maurizio; Mathieu, Laurence; Maibach, Howard I
2009-01-01
Diphoterine (Laboratoire Prevor, Valmondois, France) is an active, amphoteric, polyvalent, chelating, slightly hypertonic decontamination solution for chemical splashes to the skin and eyes. It chemically binds a large number of chemical substances present on the skin surface without causing a significant release of heat (exothermic reactions). Because of its amphoteric properties, it can bind chemically opposite substances such as acids and bases or oxidizers and reducing agents. No adverse effects have been observed in an ongoing postmarketing surveillance program during many years of use in European industrial facilities. Diphoterine has more recently been used in hospitals for delayed management of chemical burns to the skin and eyes. There is interest in having protocols for both immediate and delayed diphoterine use for skin decontamination. Whereas studies of diphoterine efficacy, clinical and in vitro or ex vivo, have been published or are in the process of being prepared for publication, no review has yet been published focusing solely on the safety of this decontamination solution. Therefore, all available studies on the safety of diphoterine are described here, including recent studies demonstrating no harmful effects on the skin. Diphoterine can be used, even on damaged skin, without toxic, irritant, allergenic, or sensitizing effects.
Comparison of impact of two decontamination solutions on the viability of the cells in human amnion.
Smeringaiova, Ingrida; Trosan, Peter; Mrstinova, Miluse Berka; Matecha, Jan; Burkert, Jan; Bednar, Jan; Jirsova, Katerina
2017-09-01
Human amniotic membrane (HAM) is used as an allograft in regenerative medicine or as a source of pluripotent cells for stem cell research. Various decontamination protocols and solutions are used to sterilize HAM before its application, but little is known about the toxicity of disinfectants on HAM cells. In this study, we tested two decontamination solutions, commercial (BASE·128) and laboratory decontamination solution (LDS), with an analogous content of antimycotic/antibiotics for their cytotoxic effect on HAM epithelial (EC) and mesenchymal stromal cells (MSC). HAM was processed in a standard way, placed on nitrocellulose scaffold, and decontaminated, following three protocols: (1) 6 h, 37 °C; (2) 24 h, room temperature; (3) 24 h, 4 °C. The viability of EC was assessed via trypan blue staining. The apoptotic cells were detected using terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL). The mean % (±SD) of dead EC (%DEC) from six fresh placentas was 12.9 ± 18.1. Decontamination increased %DEC compared to culture medium. Decontamination with BASE·128 for 6 h, 37 °C led to the highest EC viability (81.7%). Treatment with LDS at 24 h, 4 °C resulted in the lowest EC viability (55.9%) in the set. MSC were more affected by apoptosis than EC. Although the BASE·128 expresses lower toxicity compared to LDS, we present LDS as an alternative decontamination solution with a satisfactory preservation of cell viability. The basic formula of LDS will be optimised by enrichment with nutrient components, such as glucose or vitamins, to improve cell viability.
Röhm-Rodowald, Ewa; Jakimiak, Bozenna; Chojecka, Agnieszka; Zmuda-Baranowska, Magdalena; Kanclerski, Krzysztof
2012-01-01
Effective decontamination of instruments is a key element of infection control and the provision of high quality in dental care. The aim of the study was to evaluate the efficiency of decontamination procedures including cleaning, disinfection and sterilization of re-usable instruments in dental practices in Poland. The efficiency of disinfection and sterilization processes have been evaluated on the results of the questionnaires. The following information were taken into account: setting where disinfection and sterilization had been performed, preparation of dental equipment for sterilization (disinfection, washing and cleaning, packaging), the types of autoclaves and used types of sterilization cycles, routine monitoring and documentation of sterilization processes, treatment of handpieces and the frequency of surface decontamination. Data were collected from 43 dental practices (35 dental offices and 8 clinics). Disinfection and cleaning processes were performed manually in 63% of dental offices and ultrasonic baths were used in 53% of settings. Washer disinfectors were used in 23% of dental practices: in every researched clinic and in a few dental offices. All sterilization processes were performed in steam autoclaves, mainly in small steam sterilizers (81%). Dental handpieces were sterilized in 72% of practices, but only 33% of them performed sterilization in recommended cycle B. Sterilization processes were monitored with chemical indicators in 33% of practices. Biological monitoring of the processes was carried out at different intervals. Incorrect documentation of instruments and surfaces decontamination was recorded in several settings. There is still a need for improvement of decontamination processes in dental practice in Poland. Areas for improvement include: replacement of manual cleaning and disinfection processes with automatic processes, sterilization of dental handpieces after each patient, monitoring of a sterilization process with chemical and biological indicators. Reported incorrect procedures in decontamination of medical devices performed by questioned dentists and lack or inadequate response to asked questions indicate the lack of adequate knowledge about decontamination. Personnel who performs decontamination processes should be continuously trained.
A Year in the Life of a Contaminated Heater-Cooler Unit With Mycobacterium chimaera?
Garvey, Mark I; Bradley, Craig W; Walker, Jimmy
2017-06-01
OBJECTIVE Heater-cooler units (HCUs) have been shown to be a source of Mycobacterium chimaera infections. For the past year, weekly water samples have been taken from HCUs used at University Hospitals Birmingham (UHB) NHS Foundation Trust. We report the microbial contamination of the HCUs over a year detailing the decontamination regimes applied at UHB to reduce the microbial load. DESIGN Observational study SETTING UHB is a tertiary referral teaching hospital in Birmingham, United Kingdom, that provides clinical services to nearly 1 million patients every year. The UHB Cardiac department is one of the largest in the United Kingdom and provides treatment for adult patients with a wide range of cardiac diseases. METHODS Water samples taken from HCUs used at UHB for cardiopulmonary bypass surgery were sampled over a year to determine the number of microorganisms by membrane filtration. Various decontamination processes were employed throughout the year. RESULTS Varying total viable counts containing a wide variety of microorganisms were obtained from water inside the HCUs. No M. chimaera were isolated after replacement of the HCU internal tubing. Stringent decontamination regimes resulted in degradation of the HCUs and increased TVCs after several months. CONCLUSION More work is required to ensure effective decontamination processes to reduce the microbial load within the HCUs. Our studies indicate that weekly water sampling for TVC will be required indefinitely to monitor the water quality in these units as well as regular replacement of the tubing to control the build-up of biofilm. Infect Control Hosp Epidemiol 2017;38:705-711.
Garvey, M I; Bradley, C W; Jumaa, P
2016-06-01
Over the last decade, carbapenemase-producing organisms (CPOs) have spread worldwide, becoming a major public health concern. This article reports the authors' experience in dealing with a burns patient infected with CPOs, and the decontamination methods employed to render a burns shock room safe for re-use. The shock room was cleaned after being vacated, but environmental sampling cultured multiple CPOs. A second decontamination was undertaken comprising a detergent, steam and hypochlorite clean followed by hydrogen peroxide misting, and no CPOs were cultured after subsequent environmental sampling. A burns patient harbouring CPOs contaminates the surroundings heavily, so standard cleaning is insufficient to reduce the environmental bioburden. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
APSIC Guidelines for environmental cleaning and decontamination.
Ling, Moi Lin; Apisarnthanarak, Anucha; Thu, Le Thi Anh; Villanueva, Victoria; Pandjaitan, Costy; Yusof, Mohamad Yasim
2015-01-01
This document is an executive summary of APSIC Guidelines for Environmental Cleaning and Decontamination. It describes best practices in routine cleaning and decontamination in healthcare facilities as well as in specific settings e.g. management of patients with isolation precautions, food preparation areas, construction and renovation, and following a flood. It recommends the implementation of environmental hygiene program to keep the environment safe for patients, staff and visitors visiting a healthcare facility. Objective assessment of cleanliness and quality is an essential component of this program as a method for identifying quality improvement opportunities. Recommendations for safe handling of linen and bedding; as well as occupational health and safety issues are included in the guidelines. A training program is vital to ensure consistent adherence to best practices.
[Microbiological surveillance in patients treated by bone marrow transplantation (author's transl)].
Haralambie, E; Linzenmeier, G; Nowrousian, M; Schäfer, R; Schmidt, C G
1980-01-01
Patients suffering from acute leukemia were treated by bone marrow transplantation under strict gnotobiotic conditions. The microbiological surveillance was performed during three phases: the admission phase, the phase of decontamination and reverse isolation and the reconventionalisation phase. During the second phase no infections of exogenous origine occurred. All clinically manifest infections in this phase were induced by unsuppressed endogenous bacteria. In our study the bacteria of oropharynx was the main source of infections therefore this biotop deserves special attention during the microbiological surveillance of the immune compromised host. In leukemia patients selective decontamination will be the method of choice, but considering the possibility of GvHR in patients with bone marrow transplantation a complete decontamination should be achieved.
Biomaterials for mediation of chemical and biological warfare agents.
Russell, Alan J; Berberich, Jason A; Drevon, Geraldine F; Koepsel, Richard R
2003-01-01
Recent events have emphasized the threat from chemical and biological warfare agents. Within the efforts to counter this threat, the biocatalytic destruction and sensing of chemical and biological weapons has become an important area of focus. The specificity and high catalytic rates of biological catalysts make them appropriate for decommissioning nerve agent stockpiles, counteracting nerve agent attacks, and remediation of organophosphate spills. A number of materials have been prepared containing enzymes for the destruction of and protection against organophosphate nerve agents and biological warfare agents. This review discusses the major chemical and biological warfare agents, decontamination methods, and biomaterials that have potential for the preparation of decontamination wipes, gas filters, column packings, protective wear, and self-decontaminating paints and coatings.
The efficacy of preservation methods to inactivate foodborne viruses.
Baert, L; Debevere, J; Uyttendaele, M
2009-05-31
During the last decade an increased incidence of infections and outbreaks attributed to foodborne viruses, in particular noroviruses (NoV), was observed world wide. The awareness of the presence of viruses on food emphasized the need to acquire knowledge regarding the effect of preservation methods upon viruses. Most foodborne viruses cannot be cultured in the laboratory, which hinders studies of their stability in food. Cultivable surrogate viruses, genetically related to the human infecting strains, are taken as a substitute to define inactivation rates. The last years, the number of survival and inactivation studies using various surrogate viruses increased. In this review, state-of-the-art information regarding the efficacy of preservation methods to reduce the level of viruses on food is compiled. In the first place, the effect of preservation methods establishing microbial growth inhibition (chilling, freezing, acidification, reduced water activity and modified atmosphere packaging) upon foodborne viruses is described. Secondly, the use of preservation methods establishing microbial inactivation such as heat treatment, high hydrostatic pressure processing and irradiation to eliminate viruses is discussed. In the third place, the efficacy of decontamination methods on fresh produce and purification procedures applied on live bivalve shellfish to reduce the viral load is included. These studies indicate that viruses persist well on chilled, acidified, frozen foods and foods packed under modified atmosphere or in dried conditions. Intervention strategies inducing microbial inactivation are required to achieve a 3 log reduction of the level of viruses. Decontamination of fresh produce reduces viruses with a maximum of 1 to 2 log while purification of live bivalves is not adequate to prevent viral outbreaks. It was noted that the effect of a particular food preservation method is dependent upon the virus tested and type of food.
Kramer, Axel; Koburger, Torsten; Taube, Lisa-Dorothea; Menzel, Michael; Meyer, Georg; Assadian, Ojan
2012-01-01
A frequent problem in dental units is the microbial contamination of water and biofilm formation in the water supply lines. After random identification of a bacterial contaminated dental unit (310 cfu/ml) in a practise with 3 dental units we implemented the present study to evaluate the efficacy of the PotoClean(®) technology, based on anodic oxidation. The efficacy of a regular low concentrated permanent decontamination (1 mg Cl/L) with an additional intensive decontamination by PotoClean(®) (three times 20 mg Cl/ml for 2 h) on three dental units was tested over 7 months. Microbial contamination, total chlorine concentration and redox potential have been analyzed. Dental unit A and B was 15 years old, unit C 5 years. After 3 intensive decontaminations, in dental unit A and B the number of bacteria and moulds could be reduced less than 7 d. Thereafter the bacteria counts increased again during the subsequent 7 month period and the amount of moulds was with some exceptions 300 cfu/ml, although PotoClean(®) was constantly added in the system (1 mg Cl/L). After further 7.5 month only with low concentrated permanent disinfection (1 mg Cl/L) both units were successful decontaminated. Dental unit C represented an object which was easier to decontaminate because of the advanced construction (prevention of water stagnation) and the shorter useful life. At the beginning of the decontamination it was no bacterial contamination, but moulds were contained (300 cfu/ml). Already after the first intensive decontamination, no further bacteria and moulds could be detected. An important factor for the efficacy of PotoClean(®) was the age of the units and their construction. For a new generation of dental units PotoClean(®) was effective during the whole period of monitoring. For two old types of dental unit with massive biofilm development the successful decontamination needed more than 7 month. The PotoClean(®) technology has resulted in even old-type turbines with intensive biofilm formation to complete decontamination. In a recent turbine design already after the first intensive decontamination with PotoClean(®) and its continuous use (1 mg Cl/L) no more contamination by bacteria and moulds were detectable.
Smolle, C; Huss, F; Lindblad, M; Reischies, F; Tano, E
2018-01-01
Healthcare textiles are increasingly recognized as potential vehicles for transmission of hospital-acquired infections. This study tested the ability of an automated ultraviolet-C (UV-C) room disinfection device (Tru-D Smart UV-C) to decontaminate textiles inoculated with Enterococcus faecium in a clinical setting. Contaminated polycotton (50/50 polyester/cotton) swatches were distributed to predefined locations in a ward room and exposed to UV-C light. UV-C decontamination reduced E. faecium counts by a mean log 10 reduction factor of 1.37 (all P = 0.005, Wilcoxon signed rank test). UV-C decontamination may be a feasible adjunctive measure to conventional laundering to preserve the cleanliness of healthcare textiles in ward rooms. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1996-06-01
This report documents the second phase of the Remote Operated Vehicle with CO{sub 2} Blasting (ROVCO{sub 2}) Program. The ROVCO{sub 2} Program`s goal is to develop and demonstrate a tool to improve the productivity of concrete floor decontamination. The second phase integrated non-developmental subsystems on to the ROVCO{sub 2} system and performed quantitative decontamination effectiveness, productivity, and reliability testings. The report documents these development activities and the analysis of cost and performance. The results show that the ROVCO{sub 2} system is an efficient decontamination tool.
Cold plasma decontamination using flexible jet arrays
NASA Astrophysics Data System (ADS)
Konesky, Gregory
2010-04-01
Arrays of atmospheric discharge cold plasma jets have been used to decontaminate surfaces of a wide range of microorganisms quickly, yet not damage that surface. Its effectiveness in decomposing simulated chemical warfare agents has also been demonstrated, and may also find use in assisting in the cleanup of radiological weapons. Large area jet arrays, with short dwell times, are necessary for practical applications. Realistic situations will also require jet arrays that are flexible to adapt to contoured or irregular surfaces. Various large area jet array prototypes, both planar and flexible, are described, as is the application to atmospheric decontamination.
A Short Take-Off/Vertical Landing (STOVL) Aircraft Carrier (S-CVX).
1998-05-01
distance for the S-CVXcan be covered in less than 20 days at 25 kts even with a half-day stop for refueling. Transit time differences for Norfolk to...efficiency concerns will result in a rather limited selection of basic weapon types with variants to accommodate different mission requirements. This...components shall be decontaminated through use of a countermeasure wash down system and portable Decontamination (DECON) methods . This requirement
PRECIPITATION METHOD OF SEPARATING PLUTONIUM FROM CONTAMINATING ELEMENTS
Sutton, J.B.
1958-02-18
This patent relates to an improved method for the decontamination of plutonium. The process consists broadly in an improvement in a method for recovering plutonium from radioactive uranium fission products in aqueous solutions by decontamination steps including byproduct carrier precipitation comprising the step of introducing a preformed aqueous slurry of a hydroxide of a metal of group IV B into any aqueous acidic solution which contains the plutonium in the hexavalent state, radioactive uranium fission products contaminant and a by-product carrier precipitate and separating the metal hydroxide and by-product precipitate from the solution. The process of this invention is especially useful in the separation of plutonium from radioactive zirconium and columbium fission products.
Possibilities of a metal surface radioactive decontamination using a pulsed CO2 laser
NASA Astrophysics Data System (ADS)
Milijanic, Scepan S.; Stjepanovic, Natasa N.; Trtica, Milan S.
2000-01-01
There is a growing interest in the laser radioactive decontamination of metal surfaces. It offers advantages over conventional methods: improved safety, reduction of secondary waste, reduced waste volume, acceptable cost. A main mechanism of cleaning in by lasers is ablation. In this work a pulsed TEA CO2 laser was used for surface cleaning, primarily in order to demonstrate that the ablation from metal surfaces with this laser is possible even with relatively low pulse energies, and secondary, that it could be competitive with other lasers because of much higher energy efficiencies. The laser pulse contains two parts, one strong and shot peak at the beginning, followed with a tail. The beam was focused onto a contaminated surface with a KBr lens. The surface was contaminated with 137Cs. Three different metals were used: stainless steel, copper and aluminum. The evaporated material was pumped out in air atmosphere and transferred to a filter. Presence of the activity on the filter was proved by a germanium detector-multichannel analyzer. Activity levels were measured by a GM counter. Calculated decontamination factors as well as collection factors have shown that ablation takes place with relatively high efficiency of decontamination. This investigation suggests that decontamination using the CO2 laser should be seriously considered.
Abis, Gabor S A; Stockmann, Hein B A C; van Egmond, Marjolein; Bonjer, Hendrik J; Vandenbroucke-Grauls, Christina M J E; Oosterling, Steven J
2013-12-01
Gastrointestinal surgery is associated with a high incidence of infectious complications. Selective decontamination of the digestive tract is an antimicrobial prophylaxis regimen that aims to eradicate gastrointestinal carriage of potentially pathogenic microorganisms and represents an adjunct to regular prophylaxis in surgery. Relevant studies were identified using bibliographic searches of MEDLINE, EMBASE, and the Cochrane database (period from 1970 to November 1, 2012). Only studies investigating selective decontamination of the digestive tract in gastrointestinal surgery were included. Two randomized clinical trials and one retrospective case-control trial showed significant benefit in terms of infectious complications and anastomotic leakage in colorectal surgery. Two randomized controlled trials in esophageal surgery and two randomized clinical trials in gastric surgery reported lower levels of infectious complications. Selective decontamination of the digestive tract reduces infections following esophageal, gastric, and colorectal surgeries and also appears to have beneficial effects on anastomotic leakage in colorectal surgery. We believe these results provide the basis for a large multicenter prospective study to investigate the role of selective decontamination of the digestive tract in colorectal surgery.
None
2017-12-09
The R&D 100 Award winning Rad-Release Chemical Decontamination Technology is a highly effective (up to 99% removal rate), affordable, patented chemical-foam-clay decontamination process tailored to specific radiological and metal contaminants, which is applicable to a wide variety of substrates. For more information about this project, visit http://www.inl.gov/rd100/2011/rad-release/
Testing and evaluation of light ablation decontamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Demmer, R.L.; Ferguson, R.L.
1994-10-01
This report details the testing and evaluation of light ablation decontamination. It details WINCO contracted research and application of light ablation efforts by Ames Laboratory. Tests were conducted with SIMCON (simulated contamination) coupons and REALCON (actual radioactive metal coupons) under controlled conditions to compare cleaning effectiveness, speed and application to plant process type equipment.
USDA-ARS?s Scientific Manuscript database
Several antimicrobial compounds have been implemented in commercial meat processing plants for decontamination of pathogens on beef carcasses, but there are many commercially available, novel antimicrobial compounds that may be more effective and suitable to be implemented in beef processing pathoge...
This treatability study report presents the results of laboratory and field tests on the effectiveness of a new decontamination process for soils containing 2,4-D/2,4,5-T and traces of dioxin. The process employs three operations, thermal desorption, condensation and absorp...
Tsubokura, Masaharu; Nihei, Masahiko; Sato, Katsumi; Masaki, Shin; Sakuma, Yu; Kato, Shigeaki; Sugimoto, Amina; Nomura, Shuhei; Matsumura, Tomoko; Miyazaki, Makoto; Hayano, Ryugo; Shibuya, Kenji; Kami, Masahiro; Sasaki, Taro
2013-10-01
Decontamination workers may face a high risk of exposure to internal irradiation through inhalation during decontamination activities; there is, however, little previous research on the levels of internal contamination during decontamination procedures. The authors reviewed the medical records, including whole body counter measurements, of decontamination workers in villages near the crippled Fukushima Daiichi Nuclear Power Plant to assess their levels of internal radiation exposure. In total, 83 decontamination workers were enrolled in this study. They were regularly engaged in decontamination activities in highly contaminated areas where surface 137Cs deposition density was over 100 kBq m-2. The present study showed low levels of internal exposure among the decontamination workers near the Fukushima Daiichi nuclear plant. The cesium burdens of all the decontamination workers were below detection limits. They had reported no acute health problems. The resuspension of radioactive materials may cause minimal internal contamination during decontamination activities.
Dorandeu, F; Taysse, L; Boudry, I; Foquin, A; Hérodin, F; Mathieu, J; Daulon, S; Cruz, C; Lallement, G
2011-06-01
Exposure to lethal chemical warfare agents (CWAs) is no longer only a military issue due to the terrorist threat. Among the CWAs of concern are the organophosphorus nerve agent O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX) and the vesicant sulfur mustard (SM). Although efficient means of decontamination are available, most of them lose their efficacy when decontamination is delayed after exposure of the bare skin. Alternatively, CWA skin penetration can be prevented by topical skin protectants. Active research in skin protection and decontamination is thus paramount. In vivo screening of decontaminants or skin protectants is usually time consuming and may be expensive depending on the animal species used. We were thus looking for a suitable, scientifically sound and cost-effective model, which is easy to handle. The euthymic hairless mouse Crl: SKH-1 (hr/hr) BR is widely used in some skin studies and has previously been described to be suitable for some experiments involving SM or SM analogs. To evaluate the response of this species, we studied the consequences of exposing male anaesthetized SKH-1 mice to either liquid VX or to SM, the latter being used in liquid form or as saturated vapours. Long-term effects of SM burn were also evaluated. The model was then used in the companion paper (Taysse et al.(1)).
Decontamination issues for chemical and biological warfare agents: how clean is clean enough?
Raber, E; Jin, A; Noonan, K; McGuire, R; Kirvel, R D
2001-06-01
The objective of this assessment is to determine what level of cleanup will be required to meet regulatory and stakeholder needs in the case of a chemical and/or biological incident at a civilian facility. A literature review for selected, potential chemical and biological warfare agents shows that dose information is often lacking or controversial. Environmental regulatory limits or other industrial health guidelines that could be used to help establish cleanup concentration levels for such agents are generally unavailable or not applicable for a public setting. Although dose information, cleanup criteria, and decontamination protocols all present challenges to effective planning, several decontamination approaches are available. Such approaches should be combined with risk-informed decision making to establish reasonable cleanup goals for protecting health, property, and resources. Key issues during a risk assessment are to determine exactly what constitutes a safety hazard and whether decontamination is necessary or not for a particular scenario. An important conclusion is that cleanup criteria are site dependent and stakeholder specific. The results of a modeling exercise for two outdoor scenarios are presented to reinforce this conclusion. Public perception of risk to health, public acceptance of recommendations based on scientific criteria, political support, time constraints, and economic concerns must all be addressed in the context of a specific scenario to yield effective and acceptable decontamination.
2013-01-01
Introduction Selective decontamination of the digestive tract (SDD) is a prophylactic antibiotic regimen that is not widely used in practice. We aimed to describe the opinions of key ‘stakeholders’ about the validity of the existing evidence base, likely consequences of implementation, relative importance of their opinions in influencing overall practice, likely barriers to implementation and perceptions of the requirement for further research to inform the decision about whether to embark on a further large randomised controlled trial. Methods This was a Delphi study informed by comprehensive framework of possible determinants of health professionals’ behaviour to study Critical Care practice in four countries. There were four key stakeholder participant groups including ICU physicians, pharmacists, clinical leads, and clinical microbiologists/ infectious disease physicians. Round one comprised participant interviews and Rounds two and three were online questionnaires using Delphi method. Results In this study, 141 participants were recruited of whom 82% were retained. Participants rated themselves as knowledgeable about SDD. Antibiotic resistance was identified as the most important issue. SDD was seen as a low clinical priority but few participants reported strong opposition. There was moderate agreement that research to date has not adequately addressed concerns about antibiotic resistance and lacks generalizability. Participants indicated equipoise with regard to benefits and harms of SDD, and indicated strong support for a further randomised trial. Conclusions Clinicians have clinical equipoise about the effectiveness of SDD. Future research requires longer follow up to assess antibiotic resistance as well as greater validity/generalizability to provide definitive answers on the effectiveness of decontamination and effects on antibiotic resistance. SDD was regarded as not being a high clinical priority, which may limit future trial participation. These results have identified that further large randomised controlled trial of SDD in critical care is both warranted and appropriate. PMID:24207137
van Nieuwenhoven, Christianne A; Buskens, Erik; Bergmans, Dennis C; van Tiel, Frank H; Ramsay, Graham; Bonten, Marc J M
2004-01-01
Although the development of ventilator-associated pneumonia (VAP) is assumed to increase costs of intensive care unit stay, it is unknown whether prevention of VAP by means of oropharyngeal decontamination is cost-effective. Because of wide ranges of individual patient costs, crude cost comparisons did not show significant cost reductions. Based on actual cost data of 181 individual patients included in a former randomized clinical trial, cost-effectiveness of prevention of VAP was determined using a decision model and univariate sensitivity analyses, and bootstrapping was used to assess the impact of variability in the various outcomes. Published data on prevention of VAP by oropharyngeal decontamination, which resulted in a relative risk for VAP of 0.45, with a baseline rate of VAP of 29% among control patients. The mean costs of the intervention were 351 dollars per patient (32 dollars per patient per day). All other costs were derived from the hospital administrative database for all individual patients. Prevention of VAP led to mean total costs of 16,119 dollars and 18,268 dollars for patients without preventive measures administered. Thus, costs were saved and instances of VAP were prevented. Similar results were observed in terms of overall survival. Prevention of VAP remains cost-saving if the relative risk for VAP because of intervention is <0.923, the costs of the intervention are less than 2,500 dollars, and the prevalence of VAP without intervention is >4%. Bootstrapping confirmed that, with about 80% certainty, oropharyngeal decontamination results in prevention of VAP and simultaneously saves costs. In terms of a survival benefit, the results are less evident; the results indicate that with only about 60% certainty can we confirm that oropharyngeal decontamination would result in a survival benefit and simultaneously save costs. This study provides strong evidence that prevention of VAP by means of oropharyngeal decontamination is cost-effective.
Verification of screening level for decontamination implemented after Fukushima nuclear accident
Ogino, Haruyuki; Ichiji, Takeshi; Hattori, Takatoshi
2012-01-01
The screening level for decontamination that has been applied for the surface of the human body and contaminated handled objects after the Fukushima nuclear accident was verified by assessing the doses that arise from external irradiation, ingestion, inhalation and skin contamination. The result shows that the annual effective dose that arises from handled objects contaminated with the screening level for decontamination (i.e. 100 000 counts per minute) is <1 mSv y−1, which can be considered as the intervention exemption level in accordance with the International Commission on Radiological Protection recommendations. Furthermore, the screening level is also found to protect the skin from the incidence of a deterministic effect because the absorbed dose of the skin that arises from direct deposition on the surface of the human body is calculated to be lower than the threshold of the deterministic effect assuming a practical exposure duration. PMID:22228683
Bebko, Serge P; Green, David M; Awad, Samir S
2015-05-01
Surgical site infections (SSIs), commonly caused by methicillin-resistant Staphylococcus aureus (MRSA), are associated with significant morbidity and mortality, specifically when hardware is implanted in the patient. Previously, we have demonstrated that a preoperative decontamination protocol using chlorhexidine gluconate washcloths and intranasal antiseptic ointment is effective in eradicating MRSA in the nose and on the skin of patients. To examine the effect of a decontamination protocol on SSIs in patients undergoing elective orthopedic surgery with hardware implantation. A prospective database of patients undergoing elective orthopedic surgery with hardware implantation at the Michael E. DeBakey Veterans Affairs Medical Center in Houston, Texas, was analyzed from October 1, 2012, to December 31, 2013. Cohort groups before and after the intervention were compared. Starting in May 2013, during their preoperative visit, all of the patients watched an educational video about MRSA decontamination and were given chlorhexidine washcloths and oral rinse and nasal povidone-iodine solution to be used the night before and the morning of scheduled surgery. Thirty-day SSI rates were collected according to the definitions of the Centers for Disease Control and Prevention National Nosocomial Infections Surveillance. Data on demographics, comorbidities such as chronic obstructive pulmonary disease and coronary artery disease, tobacco use, alcohol use, and body mass index were also collected. Univariate analysis was performed between the 2 groups of patients. Multivariate analysis was used to identify independent predictors of SSI. A total of 709 patients were analyzed (344 controls and 365 patients who were decolonized). Both groups were well matched with no significant differences in age, body mass index, sex, or comorbidities. All of the patients (100%) completed the MRSA decontamination protocol. The SSI rate in the intervention group was significantly lower (1.1%; 4 of 365 patients developed an SSI) than the SSI rate in the control group (3.8%; 13 of 344 patients developed an SSI) (P = .02). Multivariate logistic regression identified MRSA decontamination as an independent predictor of not developing an SSI (adjusted odds ratio, 0.24 [95% CI, 0.08-0.77]; P = .02). Our study demonstrates that preoperative MRSA decontamination with chlorhexidine washcloths and oral rinse and intranasal povidone-iodine decreased the SSI rate by more than 50% among patients undergoing elective orthopedic surgery with hardware implantation. Universal decontamination using this low-cost protocol may be considered as an additional prevention strategy for SSIs in patients undergoing orthopedic surgery with hardware implantation and warrants further study.
Thors, L; Koch, M; Wigenstam, E; Koch, B; Hägglund, L; Bucht, A
2017-08-01
The decontamination efficacy of four commercially available skin decontamination products following exposure to the nerve agent VX was evaluated in vitro utilizing a diffusion cell and dermatomed human skin. The products included were Reactive Skin Decontamination Lotion (RSDL), the Swedish decontamination powder 104 (PS104), the absorbent Fuller's Earth and the aqueous solution alldecontMED. In addition, various decontamination procedures were assessed to further investigate important mechanisms involved in the specific products, e.g. decontamination removal from skin, physical removal by sponge swabbing and activation of degradation mechanisms. The efficacy of each decontamination product was evaluated 5 or 30 min after dermal application of VX (neat or diluted to 20% in water). The RSDL-lotion was superior in reducing the penetration of VX through human skin, both when exposed as neat agent and when diluted to 20% in water. Swabbing with the RSDL-sponge during 2 min revealed decreased efficacy compared to applying the RSDL-lotion directly on the skin for 30 min. Decontamination with Fuller's Earth and alldecontMED significantly reduced the penetration of neat concentration of VX through human skin. PS104-powder was insufficient for decontamination of VX at both time-points, independently of the skin contact time of PS104. The PS104-slurry (a mixture of PS104-powder and water), slightly improved the decontamination efficacy. Comparing the time-points for initiated decontamination revealed less penetrated VX for RSDL and Fuller's Earth when decontamination was initiated after 5 min compared to 30 min post-exposure, while alldecontMED displayed similar efficacy at both time-points. Decontamination by washing with water only resulted in a significant reduction of penetrated VX when washing was performed 5 min after exposure, but not when decontamination was delayed to 30 min post-exposure of neat VX. In conclusion, early initiated decontamination with the RSDL-lotion, containing both absorption and degrading properties, allowed to act on skin for 30 min was superior in preventing VX from penetrating human skin. Adding water during decontamination resulted in increased penetration of neat VX, however, water in the decontaminant removal process did not influence the decontamination efficacy. From our study on commercially available decontaminants, it is recommended that future product developments should include both strong absorbents and efficient nerve agent degrading components. Copyright © 2017 Elsevier B.V. All rights reserved.
Xu, Wenqing; Chen, Haiqiang; Huang, Yaoxin; Wu, Changqing
2013-08-16
Imported green onion has been associated with three large outbreaks in the USA. Contamination has been found on both domestic and imported green onions. The objective of our study was to investigate Escherichia coli O157:H7 inactivation efficacy of pulsed light (PL) as well as its combination with surfactant and/or sanitizers on green onions. Green onions were cut into two segments, stems and leaves, to represent two different matrixes. Stems were more difficult to be decontaminated. Spot and dip inoculation methods were compared and dipped inoculated green onions were found to be more difficult to be decontaminated. Results showed that 5s dry PL (samples were not immersed in water during PL treatment) and 60s wet PL (samples were immersed in water and stirred during PL treatment) treatments provided promising inactivation efficacy (>4log10CFU/g) for spot inoculated stems and leaves. For dip inoculated green onions, 60s wet PL treatment was comparable with 100ppm chlorine washing, demonstrating that PL could be used as an alternative to chlorine. To further increase the degree of microbial inactivation, combined treatments were applied. PL combined with surfactant (SDS) was found to be more effective than single treatments of PL, SDS, chlorine, citric acid, thymol, and hydrogen peroxide, and binary combined treatments of PL with one of those chemicals. Addition of chlorine or hydrogen peroxide to the PL-SDS combination did not further enhanced its microbial inactivation efficacy. The combination of PL and 1000ppm of SDS reduced the E. coli O157:H7 populations dip inoculated on the stems and leaves of green onions by 1.4 and 3.1log10CFU/g, respectively. Our findings suggest that PL could potentially be used for decontamination of E. coli O157:H7 on green onions, with wet PL added with SDS being the most effective PL treatment. © 2013.
Learning and Retention Using Virtual Reality in a Decontamination Simulation.
Smith, Sherrill J; Farra, Sharon; Ulrich, Deborah L; Hodgson, Eric; Nicely, Stephanie; Matcham, William
The purpose of this study was to examine the longitudinal effects of virtual reality simulation (VRS) on learning outcomes and retention. Disaster preparation for health care professionals is seriously inadequate. VRS offers an opportunity to practice within a realistic and safe environment, but little is known about learning and retention using this pedagogy. A quasiexperimental design was used to examine the use of VRS with baccalaureate nursing students in two different nursing programs in terms of the skill of decontamination. Results indicate that VRS is at least as good as traditional methods and is superior in some cases for retention of knowledge and performance of skills. VRS may provide a valuable option for promoting skill development and retention. More research is needed to determine how to prepare nurses for skills that may not be required until months or even years after initial introduction.
Li, Yanqin; Gao, Qi; Zhang, Lijuan; Zhou, Yunshan; Zhong, Yuxu; Ying, Ying; Zhang, Mingcai; Huang, Chunqian; Wang, Yong'an
2018-05-08
Currently extensive effort is compulsively expended to decontaminate efficiently banned chemical war agents. In this work, H5PV2Mo10O40 molecules have been encapsulated in mesoporous MIL-101(Cr), which features two types of mesoporous cages (internal diameters of 29 Å and 34 Å) and microporous windows (diameters of 12 Å and 16 Å), leading to the formation of a new composite H5PV2Mo10O40@MIL-101(Cr) through a simple impregnation method. The composite was characterized thoroughly by elemental analysis, FT-IR spectroscopy, powder X-ray diffraction, scanning electron microscopy, energy dispersive X-ray spectroscopy, TG/DTA, and textural analysis thereby confirming the encapsulation of the H5PV2Mo10O40 into MIL-101(Cr). The decontamination efficiency of sulfur mustard (4 μL HD in 40 μL of petroleum ether) by 20 mg of the composite is found to be 97.39% in 120 min under ambient conditions. GC-MS analysis on the decontaminated products using 2-chloroethyl ethyl sulfide (CEES), which has been widely used as a simulant of sulfur mustard, showed that MIL-101(Cr) just decontaminates CEES by adsorption, while CEES can be decontaminated under ambient conditions by a synergetic combination of adsorption of MIL-101(Cr) and subsequent chemical oxidation degradation to nontoxic 2-chloroethyl ethyl sulfoxide (CEESO) due to the presence of highly dispersed H5PV2Mo10O40 within the composites.
Endo, Shota; Kakamu, Takeyasu; Sato, Sei; Hidaka, Tomoo; Kumagai, Tomohiro; Nakano, Shinichi; Koyama, Kikuo; Fukushima, Tetsuhito
2017-01-01
Objectives: The aim of this study was to reveal the current state of preventive measures and lifestyle habits against heat illness in radiation decontamination workers and to examine whether young radiation decontamination workers take less preventive measures and have worse lifestyle habits than the elder workers. Methods: This was a cross-sectional study. Self-administered questionnaires were sent to 1,505 radiation decontamination workers in Fukushima, Japan. Five hundred fifty-eight men who replied and answered all questions were included in the statistical analysis. The questionnaire included age, duration of decontamination work, previous occupation, lifestyle habit, and preventive measures for heat illness. We classified age of the respondents into five groups: <30, 30-39, 40-49, 50-59, and ≥60 years and defined the workers under 30 years of age as young workers. Logistic regression analysis was used to reveal the factors associated with each lifestyle habit and preventive measures. Results: In comparison with young workers, 50-59-year-old workers were significantly associated with refraining from drinking alcohol. Workers 40 years of age or older were significantly associated with cooling their bodies with refrigerant. Furthermore, 30-39-year-old workers and 40-49-year-old workers were significantly associated with adequate consumption of water compared to young workers. Conclusion: The results of our study suggests that young decontamination workers are more likely to have worse lifestyle habits and take insufficient preventive measures for heat illness. This may be the cause of higher incidence of heat illness among young workers. PMID:28794393
DESCALING AND DECONTAMINATING METHOD FOR METALS
Baybarz, R.D.
1961-04-25
Oxide scale is removed from the surface of stainless steels and similar metals by contacting the metal under an inert atmosphere with a dilute sulfuric acid solution containing chromous sulfate. The removed oxide scale is either dissolved or disintegrated into a slurry by the solution. Preferred reagent concentrations are 0.3 to 0.5 M chromous sulfate and 0.4 to 0.6 M sulfuric acid. This process is particularly applicable to decontamination of aqueous homogsneous nuclear reactor systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J.L.; Garcia, F.; Garza, R.G.
Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculationalmore » method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less
2006-11-01
spores of B. stearothermophilus . For all of the test organisms, conditions were found that effected sterilization (6-log kill of contaminating...kill 106 E. coli, L. monocytogenes, S. aureus, and bacterial spores of B. atrophaeus and B. stearothermophilus and to sterilize high-grade...Portable Chemical Sterilizer for Microbial Decontamination of
Advances in Sterilization and Decontamination: a Survey
NASA Technical Reports Server (NTRS)
1978-01-01
Recent technical advances made in the field of sterilization and decontamination and their applicability to private and commercial interests are discussed. Government-sponsored programs by NASA produced the bulk of material presented in this survey. The summary of past and current research discussed is detailed to enhance an effective transfer of technology from NASA to potential users.
Mass Casualty Decontamination in the United States: An Online Survey of Current Practice
Power, Sarah; Symons, Charles; Carter, Holly; Jones, Emma; Larner, Joanne; Matar, Hazem; Chilcott, Robert P.
2016-01-01
Mass casualty decontamination is a public health intervention that would be employed by emergency responders following a chemical, biological, or radiological incident. The decontamination of large numbers of casualties is currently most often performed with water to remove contaminants from the skin surface. An online survey was conducted to explore US fire departments' decontamination practices and their preparedness for responding to incidents involving mass casualty decontamination. Survey respondents were asked to provide details of various aspects of their decontamination procedures, including expected response times to reach casualties, disrobing procedures, approaches to decontamination, characteristics of the decontamination showering process, provision for special populations, and any actions taken following decontamination. The aim of the survey was to identify any differences in the way in which decontamination guidance is implemented across US states. Results revealed that, in line with current guidance, many US fire departments routinely use the “ladder-pipe system” for conducting rapid, gross decontamination of casualties. The survey revealed significant variability in ladder-pipe construction, such as the position and number of fire hoses used. There was also variability in decontamination characteristics, such as water temperature and water pressure, detergent use, and shower duration. The results presented here provide important insights into the ways in which implementation of decontamination guidance can vary between US states. These inconsistencies are thought to reflect established perceived best practices and local adaptation of response plans to address practical and logistical constraints. These outcomes highlight the need for evidence-based national guidelines for conducting mass casualty decontamination. PMID:27442794
Taysse, L; Dorandeu, F; Daulon, S; Foquin, A; Perrier, N; Lallement, G; Breton, P
2011-06-01
Using the hairless mouse screening model presented in the companion paper(1) the aim of this study was to assess two skin decontaminating systems: Fuller's earth (FE) and Reactive Skin Decontamination Lotion (RSDL) against two extremely toxic chemical warfare agents that represent a special percutaneous hazard, sulphur mustard (SM) and O-ethyl-S-(2[di-isopropylamino]ethyl)methyl-phosphonothioate (VX). Five minutes after being exposed on the back to either 2 µL of neat sulphur mustard or 50 µg.kg(-1) of diluted VX, mice were decontaminated. Both systems were able to reduce blisters 3 days after SM exposure. However, RSDL was found to be more efficient than FE in reducing the necrosis of the epidermis and erosion. In the case of VX exposure, RSDL, whatever the ratio of decontaminant to toxicant used (RSDL 10, 20, 50), was not able to sufficiently prevent the inhibition of plasma cholinesterases taken as a surrogate marker of exposure and toxicity. Only FE reduced significantly the ChE inhibition. Some of these observations are different from our previous results obtained in domestic swine and these changes are thus discussed in the perspective of using SKH-1 hairless mice for the initial in vivo screening of decontaminants.
Gamma radiation effects on physical properties of parchment documents: Assessment of Dmax
NASA Astrophysics Data System (ADS)
Nunes, Inês; Mesquita, Nuno; Cabo Verde, Sandra; João Trigo, Maria; Ferreira, Armando; Manuela Carolino, Maria; Portugal, António; Luísa Botelho, Maria
2012-12-01
Parchments are important documents that give testimony for History; therefore these materials should be respected and preserved. Considering incremental biodeterioration problems that have to be faced daily, the Archive of the University of Coimbra (AUC) is involved in different scientific projects in order to evaluate and determine new methods for document decontamination and preservation. The aim of this study was to evaluate gamma radiation effects on the colour and texture of the AUC parchment documents. The assessment of these effects was used to estimate the maximum gamma radiation dose (Dmax) that could guarantee parchment documents' decontamination treatment, without significant alteration of their physical properties. Parchment samples were exposed to gamma radiation doses ranging from 10 to 30 kGy. The texture and colour of samples were assessed before and after the irradiation procedure, using a texture analyser and an electronic colorimeter. Hardness and springiness were determined based on texture spectra. Lightness (L*), Chroma (C), greenness vs. redness (a*) and yellowness vs. blueness (b*) values were obtained from colorimetric measures. Results indicate no significant effects of gamma radiation on the texture and colour of parchment for the studied doses.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Maienschein, J.L.; Garcia, F.; Garza, R.G.
Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish{trademark}. The surface contamination, as shown by swipe surveys, was reduced from 4{times}10{sup 4}--10{sup 6} disintegrations per minute (dpm)/cm{sup 2} to 2{times}10{sup 2}--4{times}10{sup 4} dpm/cm{sup 2}. Details on the decontamination operation are provided. A seriesmore » of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given.« less
Matar, Hazem; Guerreiro, Antonio; Piletsky, Sergey A; Price, Shirley C; Chilcott, Robert P
2015-08-13
Rapid decontamination is vital to alleviate adverse health effects following dermal exposure to hazardous materials. There is an abundance of materials and products which can be utilised to remove hazardous materials from the skin. In this study, a total of 15 products were evaluated, 10 of which were commercial or military products and five were novel (molecular imprinted) polymers. The efficacies of these products were evaluated against a 10 µl droplet of 14 C-methyl salicylate applied to the surface of porcine skin mounted on static diffusion cells. The current UK military decontaminant (Fuller's earth) performed well, retaining 83% of the dose over 24 h and served as a benchmark to compare with the other test products. The five most effective test products were Fuller's earth (the current UK military decontaminant), Fast-Act® and three novel polymers [based on itaconic acid, 2-trifluoromethylacrylic acid and N,N-methylenebis(acrylamide)]. Five products (medical moist-free wipes, 5% FloraFree™ solution, normal baby wipes, baby wipes for sensitive skin and Diphotérine™) enhanced the dermal absorption of 14 C-methyl salicylate. Further work is required to establish the performance of the most effective products identified in this study against chemical warfare agents.
Matar, Hazem; Guerreiro, Antonio; Piletsky, Sergey A; Price, Shirley C; Chilcott, Robert P
2016-01-01
Rapid decontamination is vital to alleviate adverse health effects following dermal exposure to hazardous materials. There is an abundance of materials and products which can be utilised to remove hazardous materials from the skin. In this study, a total of 15 products were evaluated, 10 of which were commercial or military products and five were novel (molecular imprinted) polymers. The efficacies of these products were evaluated against a 10 µl droplet of (14)C-methyl salicylate applied to the surface of porcine skin mounted on static diffusion cells. The current UK military decontaminant (Fuller's earth) performed well, retaining 83% of the dose over 24 h and served as a benchmark to compare with the other test products. The five most effective test products were Fuller's earth (the current UK military decontaminant), Fast-Act® and three novel polymers [based on itaconic acid, 2-trifluoromethylacrylic acid and N,N-methylenebis(acrylamide)]. Five products (medical moist-free wipes, 5% FloraFree™ solution, normal baby wipes, baby wipes for sensitive skin and Diphotérine™) enhanced the dermal absorption of (14)C-methyl salicylate. Further work is required to establish the performance of the most effective products identified in this study against chemical warfare agents.
Hepiegne, P; Dall'ava, D; Clement, R; Degros, J P
1995-06-01
A chemical separation method has been developed for the determination of (99)Tc in various types of radioactive wastes. Such a method includes (i) fusion with NaOH, (ii) extraction in a column containing methyltrioctylammonium chloride, (iii) extraction by solvent with N-benzoyl-N-phenylhydroxylamine and, (iv) measurement by inductively-coupled plasma mass spectrometry (ICP-MS). From the performance standpoint, the recovery of (99)Tc, using (99m)Tc as a yield tracer, is higher than 70%. This analytical method, as developed, ensures effective decontamination with respect to the radionuclides, insofar the decontamination factors are greater than 10(+5), whenever the residual activity may be measured. Taking into account a 3sigma counting error, the detection limit obtained with the ICP-MS technique is 1.9 mBq/ml; the method enabling hence to detect activities as low as 0.3 Bq/g, with analysed samples of 0.2 g and a radiochemical yield of 70%. Studies have been dedicated to the (99)Tc measurement, using the electrothermal vaporization ICP-MS technique, which lowers the detection limit by a factor 10, with the standard solution (0.3 pg/ml), compared with the previous ICP-MS technique.
NASA Technical Reports Server (NTRS)
1971-01-01
Methods for presterilization cleaning or decontamination of spacecraft hardware to reduce microbial load, without harming materials or spacecraft components, are investigated. Three methods were considered: (1) chemicals in liquid form, relying on physical removal as well as bacterial or bacteriostatic action; (2) chemicals used in the gaseous phase, relying on bacterial activity; and (3) mechanical cleaning relying on physical removal of organisms. These methods were evaluated in terms of their effectiveness in microbial burden reduction and compatibility with spacecraft hardware. Results show chemical methods were effective against spore microorganisms but were harmful to spacecraft materials. Mechanical methods were also effective with the degree depending upon the type of instrument employed. Mechanical methods caused problems in handling the equipment, due to vacuum pressure damaging the very thin layered materials used for shielding, and the bristles used in the process caused streaks or abrasions on some spacecraft components.
Waste Isolation Pilot Plant Salt Decontamination Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rick Demmer; Stephen Reese
2014-09-01
On February 14, 2014, americium and plutonium contamination was released in the Waste Isolation Pilot Plant (WIPP) salt caverns. At the request of WIPP’s operations contractor, Idaho National Laboratory (INL) personnel developed several methods of decontaminating WIPP salt, using surrogate contaminants and also americium (241Am). The effectiveness of the methods is evaluated qualitatively, and to the extent possible, quantitatively. One of the requirements of this effort was delivering initial results and recommendations within a few weeks. That requirement, in combination with the limited scope of the project, made in-depth analysis impractical in some instances. Of the methods tested (dry brushing,more » vacuum cleaning, water washing, strippable coatings, and mechanical grinding), the most practical seems to be water washing. Effectiveness is very high, and it is very easy and rapid to deploy. The amount of wastewater produced (2 L/m2) would be substantial and may not be easy to manage, but the method is the clear winner from a usability perspective. Removable surface contamination levels (smear results) from the strippable coating and water washing coupons found no residual removable contamination. Thus, whatever is left is likely adhered to (or trapped within) the salt. The other option that shows promise is the use of a fixative barrier. Bartlett Nuclear, Inc.’s Polymeric Barrier System (PBS) proved the most durable of the coatings tested. The coatings were not tested for contaminant entrapment, only for coating integrity and durability.« less
Methods of Advanced Wound Management for Care of Combined Traumatic and Chemical Warfare Injuries
Graham, John S.; Gerlach, Travis W.; Logan, Thomas P.; Bonar, James P.; Fugo, Richard J.; Lee, Robyn B.; Coatsworth, Matthew A.
2008-01-01
Objective: Chemical warfare agents are potential threats to military personnel and civilians. The potential for associated traumatic injuries is significant. Damage control surgery could expose medical personnel to agents contaminating the wounds. The objectives of this study were to demonstrate efficacy of surgical decontamination and assess exposure risk to attending personnel. Methods: Weanling pigs were randomly assigned to 2 of 4 debridement tools (scalpel, Bovie® knife, Fugo Blade®, and Versajet™ Hydrosurgery System). Penetrating traumatic wounds were created over the shoulder and thigh and then exposed to liquid sulfur mustard (HD) for 60 minutes. Excisional debridement of the injuries was performed while vapors over each site were collected. Gas chromatography was used to measure HD in samples of collected vapors. Unbound HD was quantified in presurgical wound swabs, excised tissues, and peripheral tissue biopsies following solvent extraction. Results: Excisional debridement produced agent-free wound beds (surgical decontamination). A significant amount of HD vapor was detected above the surgical fields with each tool. Apart from the Versajet™ producing significantly lower levels of HD detected over thigh wounds compared with those treated using the scalpel, there were no differences in the amount of agent detected among the tools. All measured levels significantly exceeded established safety limits. Vesicating levels of unbound HD were extracted from excised tissue. There was no measured lateral spreading of HD beyond the surgical margins. Conclusions: There is significant occupational exposure risk to HD during surgical procedures designed to stabilize agent-contaminated wounds. If appropriate protective measures are taken, surgical decontamination is both effective and safe. PMID:18716652
Murakami, Michio; Nomura, Shuhei; Morita, Tomohiro; Nishikawa, Yoshitaka; Leppold, Claire; Kato, Shigeaki; Kami, Masahiro
2017-01-01
After the 2011 Fukushima Daiichi nuclear power plant accident, little information has been available on individual doses from external exposure among residents living in radioactively contaminated areas near the nuclear plant; in the present study we evaluated yearly changes in the doses from external exposure after the accident and the effects of decontamination on external exposure. This study considered all children less than 16 years of age in Soma City, Fukushima who participated in annual voluntary external exposure screening programs during the five years after the accident (n = 5,363). In total, 14,405 screening results were collected. The median participant age was eight years. The geometric mean levels of annual additional doses from external exposure attributable to the Fukushima accident, decreased each year: 0.60 mSv (range: not detectable (ND)–4.29 mSv), 0.37 mSv (range: ND–3.61 mSv), 0.22 mSv (range: ND–1.44 mSv), 0.20 mSv (range: ND–1.87 mSv), and 0.17 mSv (range: ND–0.85 mSv) in 2011, 2012, 2013, 2014, and 2015, respectively. The proportion of residents with annual additional doses from external exposure of more than 1 mSv dropped from 15.6% in 2011 to zero in 2015. Doses from external exposure decreased more rapidly than those estimated from only physical decay, even in areas without decontamination (which were halved in 395 days from November 15, 2011), presumably due to the weathering effects. While the ratios of geometric mean doses immediately after decontamination to before were slightly lower than those during the same time in areas without decontamination, annual additional doses reduced by decontamination were small (0.04–0.24 mSv in the year of immediately after decontamination was completed). The results of this study showed that the levels of external exposure among Soma residents less than 16 years of age decreased during the five years after the Fukushima Daiichi nuclear power plant accident. Decontamination had only limited and temporal effects on reducing individual external doses. PMID:28235009
Investigation of gaseous ozone for MRSA decontamination of hospital side-rooms.
Berrington, A W; Pedler, S J
1998-09-01
A domestic, gaseous ozone generator was investigated for use in the decontamination of hospital side-rooms that have housed patients colonized with methicillin-resistant Staphylococcus aureus (MRSA). Three models of bacterial contamination were used. These were exposed to ozone generation in a standard hospital side-room for 4 and 7 h. A methicillin-sensitive and a methicillin-resistant strain of S. aureus were compared. Ozone concentrations of 0.14 ppm were reached, levels which are sufficient to cause mild pulmonary toxicity. Bacterial counts were reduced in the vicinity of the gas generator in most instances, but the effect elsewhere in the room was, at best, limited. MRSA appeared more resistant to the effects of ozone than methicillin-sensitive S. aureus. We conclude that the device tested would be inadequate for the decontamination of such hospital side-rooms.
MRSA decontamination using octenidine-based products.
Danilevicius, Mindaugas; Juzéniené, Audra; Juzénaité-Karneckiené, Indré; Veršinina, Anželika
Methicillin-resistant Staphylococcus aureus (MRSA) infections are an increasing problem worldwide with a high risk of severe illness and mortality in hospitalised patients. Patients with chronic wounds are at particular risk of developing MRSA infections. As octenidine-based products have shown promising success in decontamination in the past, the aim of the present study was to determine its efficacy, safety, and tolerability in decontaminating hospitalised MRSA-positive patients. From 1 April 2011 until 9 November 2012, 36 patients were screened MRSA-positive at the Republican Vilnius University Hospital, Vilnius, Lithuania. At least three swab tests were performed for each patient to screen for MRSA, one from each nostril and one from the perineum. In patients with wounds, an additional swab was taken from the wound surface. In the affected patients octenidine-based products were used in one or two cycles of 7 days each. In addition, adverse events were recorded and the tolerability was assessed using a 4-point scale ranging from 'very good' to 'poor'. Complete decontamination was achieved in 24 patients (67%) following treatment with the octenidine-based products. None of the patients experienced side-effects or secondary symptoms such as skin irritation or allergic reactions during the course of the study. In addition, octenidine was very well tolerated in the majority of patients (n=31; 86%). The results demonstrate that octenidine-based products are highly efficient in the multifaceted decontamination of hospitalised MRSA-positive patients. Having a range of products that can be used for full body decontamination (including the scalp and nasal passages) is of particular significance when developing an MRSA decontamination protocol, as multiple parts of the body can be affected. Combined with a favourable safety and tolerability profile, octenidine-based products thus represent a good choice in multifaceted MRSA decontamination regimes, which are necessary to curb the increasing problem of severe infections.
2006-06-01
TREATMENT AND WATER DISTRIBUTION SYSTEM DECONTAMINATION 1 . LITERATURE SURVEY Joseph J. DeFrank RESEARCH AND TECHNOLOGY DIRECTORATE June 2006 Approved for...No. 0704-0188 Public reporting burden for this collection of information is estimated to average 1 hour per response, including the time for reviewing...YOUR FORM TO THE ABOVE ADDRESS. 1 . REPORT DATE (DD-MM-YYYY) 2. REPORT TYPE 3. DATES COVERED (From - To) XX-06-2006 Literature Survey May 2004 - Aug 2004
Chemical Warfare Agent Decontamination Foaming Composition and Method
2000-03-22
Drumgoole et al. The Drumgoole patent discloses an inflatable, portable apparatus having an aqueous foam for substantially mitigating the 15 effects...by weight to about 25% by weight. Exemplary 10 foaming components include AFFF manufactured by 3M of St. Paul, Minnesota, Knockdown manufactured...amines, amino alcohols and polyamines. For example, when the foam is water-based, the corrosion inhibitor also may be used as a solvent, as described
Weber, David J; Kanamori, Hajime; Rutala, William A
2016-08-01
This article reviews 'no touch' methods for disinfection of the contaminated surface environment of hospitalized patients' rooms. The focus is on studies that assessed the effectiveness of ultraviolet (UV) light devices, hydrogen peroxide systems, and self-disinfecting surfaces to reduce healthcare-associated infections (HAIs). The contaminated surface environment in hospitals plays an important role in the transmission of several key nosocomial pathogens including methicillin-resistant Staphylococcus aureus, vancomycin-resistant Enterococcus spp., Clostridium difficile, Acinetobacter spp., and norovirus. Multiple clinical trials have now demonstrated the effectiveness of UV light devices and hydrogen peroxide systems to reduce HAIs. A limited number of studies have suggested that 'self-disinfecting' surfaces may also decrease HAIs. Many studies have demonstrated that terminal cleaning and disinfection with germicides is often inadequate and leaves environmental surfaces contaminated with important nosocomial pathogens. 'No touch' methods of room decontamination (i.e., UV devices and hydrogen peroxide systems) have been demonstrated to reduce key nosocomial pathogens on inoculated test surfaces and on environmental surfaces in actual patient rooms. Further UV devices and hydrogen peroxide systems have been demonstrated to reduce HAI. A validated 'no touch' device or system should be used for terminal room disinfection following discharge of patients on contact precautions. The use of a 'self-disinfecting' surface to reduce HAI has not been convincingly demonstrated.
A Rapid and Inexpensive Bioassay to Evaluate the Decontamination of Organophosphates
2012-01-01
weather natu- rally over time. Actual chemical degradation of the tox- in often relied on harsh chemicals such as calcium oxide and chlorine dioxide...New decontaminating compounds have been developed that are more effective or more en- vironmentally friendly, including organophosphorous acid ...quires sophisticated instrumental analytical techniques such as liquid or gas chromatography, which involves expensive equipment and trained personnel
Improved Logistics for Chemical and Biologics Decontamination for Deployed Military
2012-07-01
Inc Honolulu, HI 96826 REPORT DATE : July 2012 TYPE OF REPORT: Annual...1. REPORT DATE July 19, 2012 2. REPORT TYPE Annual 3. DATES COVERED June 20 th , 2011 – June 19 th , 2012 4. TITLE AND SUBTITLE Improved...research performed so far, that it is quite possible to develop a decontamination system effective against CWA, BWA, Radioisotopes , TICs, TIMs while
Automated decontamination of surface-adherent prions.
Schmitt, A; Westner, I M; Reznicek, L; Michels, W; Mitteregger, G; Kretzschmar, H A
2010-09-01
At present there is no routinely available decontamination procedure in washer-disinfectors to allow the reliable inactivation and/or elimination of prions present on reusable surgical instruments. This means that is not possible to provide assurance for preventing iatrogenic transmission of prion diseases. We need effective procedures in prion decontamination that can be integrated into the usual routine of reprocessing surgical instruments. This article reports on the evaluation of an automated process designed to decontaminate prions in washer-disinfectors using a quantitative, highly sensitive in vivo assay for surface-adherent 22L prions. The automated process showed great advantages when compared with conventional alkaline cleaning. In contrast, the new process was as effective as autoclaving at 134 degrees C for 2h and left no detectable prion infectivity, even for heavily contaminated surfaces. This indicates a reduction of surface-adherent prion infectivity of >7 log units. Due to its compatibility with even delicate surgical instruments, the process can be integrated into the large scale reprocessing of instruments in a central sterile supply department. The system could potentially make an important contribution to the prevention of iatrogenic transmission of prions. Copyright 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.
Wiedmer, David; Petersen, Fernanda Cristina; Lönn-Stensrud, Jessica; Tiainen, Hanna
2017-07-01
The chemical decontamination of infected dental implants is essential for the successful treatment of peri-implantitis. The aim of this study was to assess the antibacterial effect of a hydrogen peroxide-titanium dioxide (H 2 O 2 -TiO 2 ) suspension against Staphylococcus epidermidis biofilms. Titanium (Ti) coins were inoculated with a bioluminescent S. epidermidis strain for 8 h and subsequently exposed to H 2 O 2 with and without TiO 2 nanoparticles or chlorhexidine (CHX). Bacterial regrowth, bacterial load and viability after decontamination were analyzed by continuous luminescence monitoring, live/dead staining and scanning electron microscopy. Bacterial regrowth was delayed on surfaces treated with H 2 O 2 -TiO 2 compared to H 2 O 2 . H 2 O 2 -based treatments resulted in a lower bacterial load compared to CHX. Few viable bacteria were found on surfaces treated with H 2 O 2 and H 2 O 2 -TiO 2 , which contrasted with a uniform layer of dead bacteria for surfaces treated with CHX. H 2 O 2 -TiO 2 suspensions could therefore be considered an alternative approach in the decontamination of dental implants.
Sakai, Masaru; Gomi, Takashi; Nunokawa, Masanori; Wakahara, Taeko; Onda, Yuichi
2014-04-01
We investigated the biological accumulation of radiocesium in tadpoles [Rana (Pelophylax) porosa porosa] in rice paddies with and without decontamination practice at Fukushima. Radiocesium was accumulated in surface part of soils both in the control and decontaminated paddies one year after decontamination. Mean (134)Cs and (137)Cs concentrations in tadpoles in the control and decontaminated paddies were 3000 and 4500, and 600 and 890 Bq/kg dry weight, respectively. Radiocesium concentrations in surface soil (0-5 cm depth) and tadpoles in the decontaminated paddy were five times smaller than in the control paddy. These results suggest that decontamination practice can reduce radiocesium concentrations in both soil and tadpoles. However, at the decontaminated paddy, radiocesium concentrations in surface soils became 3.8 times greater one year after decontamination, which indicates that monitoring the subsequent movement of radiocesium in rice paddies and surrounding areas is essential for examining contamination propagation. Copyright © 2014 Elsevier Ltd. All rights reserved.
Bilibana, Mawethu Pascoe; Yeoh, Tzi Shien; Tang, Thean-Hock
2017-01-01
The binding specificity and affinity of aptamers have long been harnessed as the key elements in the development of aptamer-based assays, particularly aptasensing application. One promising avenue that is currently explored based on the specificity and affinity of aptamers is the application of aptamers in the decontamination assays. Aptamers have been successfully harnessed as the decontamination agents to remove contaminants from the environment and to decontaminate infectious elements. The reversible denaturation property inherent in aptamers enables the repeated usage of aptamers, which can immensely save the cost of decontamination. Analogous to the point-of-care diagnostics, there is no doubt that aptamers can also be deployed in the point-of-care aptamer-based decontamination assay, whereby decontamination can be performed anywhere and anytime for instantaneous decision-making. It is also prophesied that aptamers can also serve more than as a decontaminant, probably as a tool to capture and kill hazardous elements, particularly pathogenic agents. PMID:29225967
Inactivation of fungal contaminants on Korean traditional cashbox by gamma irradiation
NASA Astrophysics Data System (ADS)
Choi, Jong-il; Lim, Sangyong
2016-01-01
In this study, gamma irradiation was applied to decontaminate a Korean cultural artifact, a wooden cashbox stored in local museum. Fungi isolated from the wooden cashbox were identified by 18S rDNA sequencing methods. It was observed that the isolated fungi exhibited high similarity to Aspergillus niger, Penicillium verruculosum, and Trichoderma viride. Each strain was tested for sensitivity to gamma irradiation, and was inactivated by the irradiation at a dose of 5 kGy. The wooden cashbox was thus gamma-irradiated at this dose (5 kGy), and consequently decontaminated. Two months after the irradiation, when the wooden cashbox was retested to detect biological contamination, no fungi were found. Therefore, these results suggest that gamma irradiation at a low dose of 5 kGy can be applied for successful decontamination of wooden artifacts.
[Decontamination of organophosphorus compounds: Towards new alternatives].
Poirier, L; Jacquet, P; Elias, M; Daudé, D; Chabrière, E
2017-05-01
Organophosphorus coumpounds (OP) are toxic chemicals mainly used for agricultural purpose such as insecticides and were also developed and used as warfare nerve agents. OP are inhibitors of acetylcholinesterase, a key enzyme involved in the regulation of the central nervous system. Chemical, physical and biological approaches have been considered to decontaminate OP. This review summarizes the current and emerging strategies that are investigated to tackle this issue with a special emphasis on enzymatic remediation methods. During the last decade, many studies have been dedicated to the development of biocatalysts for OP removal. Among these, recent reports have pointed out the promising enzyme SsoPox isolated from the archaea Sulfolobus solfataricus. Considering both its intrinsic stability and activity, this hyperthermostable enzyme is highly appealing for the decontamination of OP. Copyright © 2017 Académie Nationale de Pharmacie. All rights reserved.
Koff, Matthew D; Brown, Jeremiah R; Marshall, Emily J; O'Malley, A James; Jensen, Jens T; Heard, Stephen O; Longtine, Karen; O'Neill, Melissa; Longtine, Jaclyn; Houston, Donna; Robison, Cindy; Moulton, Eric; Patel, Hetal M; Loftus, Randy W
2016-08-01
BACKGROUND Healthcare provider hands are an important source of intraoperative bacterial transmission events associated with postoperative infection development. OBJECTIVE To explore the efficacy of a novel hand hygiene improvement system leveraging provider proximity and individual and group performance feedback in reducing 30-day postoperative healthcare-associated infections via increased provider hourly hand decontamination events. DESIGN Randomized, prospective study. SETTING Dartmouth-Hitchcock Medical Center in New Hampshire and UMass Memorial Medical Center in Massachusetts. PATIENTS Patients undergoing surgery. METHODS Operating room environments were randomly assigned to usual intraoperative hand hygiene or to a personalized, body-worn hand hygiene system. Anesthesia and circulating nurse provider hourly hand decontamination events were continuously monitored and reported. All patients were followed prospectively for the development of 30-day postoperative healthcare-associated infections. RESULTS A total of 3,256 operating room environments and patients (1,620 control and 1,636 treatment) were enrolled. The mean (SD) provider hand decontamination event rate achieved was 4.3 (2.9) events per hour, an approximate 8-fold increase in hand decontamination events above that of conventional wall-mounted devices (0.57 events/hour); P<.001. Use of the hand hygiene system was not associated with a reduction in healthcare-associated infections (odds ratio, 1.07 [95% CI, 0.82-1.40], P=.626). CONCLUSIONS The hand hygiene system evaluated in this study increased the frequency of hand decontamination events without reducing 30-day postoperative healthcare-associated infections. Future work is indicated to optimize the efficacy of this hand hygiene improvement strategy. Infect Control Hosp Epidemiol 2016;37:888-895.
Facilities for chemical decontamination in accident and emergency departments in the United Kingdom
George, G; Ramsay, K; Rochester, M; Seah, R; Spencer, H; Vijayasankar, D; Vasicuro, L
2002-01-01
Objective: To audit the facilities for chemical decontamination, with special reference to cyanide poisoning, in all major accident and emergency departments in the UK. Method: A simple postal questionnaire was used to audit planning, premises, equipment, protection for staff, and stocks of specific antidotes to cyanide poisoning. Results: 227 questionnaires from 261 departments (87%) were returned and used in the survey. Of the 227 departments who responded, 151 (66%) had a written plan; 168 (74%) departments had premises for decontamination; 55 (24%) were judged to have satisfactory premises; 146 (64%) departments had a shower or hose for decontamination; 60 (26%) departments had a decontamination trolley suitable for "stretcher" patients; 203 (89%) had some protective equipment for staff but only 77 (34%) had complete protection—that is, goggles, chemical resistant clothing, and breathing apparatus. In the authors' opinion only seven (3%) departments had satisfactory premises and equipment to treat "stretcher" patients and full protection for staff. A further 11 (5%) departments were equipped to manage ambulant patients at a similar level. Some 205 (90%) departments stocked one or more antidotes to cyanide and 77 (34%) stocked all four antidotes. Thirty four (15%) departments held all four antidotes to cyanide and had full protection for staff. Only five (2%) departments had satisfactory premises and equipment to treat "stretcher" patients, full protection for staff, and at least three of four antidotes. Conclusions: Most departments had some equipment for chemical decontamination. However, there were major inconsistencies in the range of equipment held and these limited its usefulness. Only a small minority of departments was satisfactorily equipped to deal with a serious chemical incident. PMID:12205006
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cristy, G.A.; Jernigan, H.C.
1981-02-01
The record of the proceedings of the workshop on environmental decontamination contains twenty-seven presentations. Emphasis is placed upon soil and surface decontamination, the decommissioning of nuclear facilities, and assessments of instrumentation and equipment used in decontamination. (DLS)
Abolghasemi Mahani, A; Motahari, S; Mohebbi, A
2018-04-01
Oil spills are the most important threat to the sea ecosystem. The present study is an attempt to investigate the effects of sol-gel parameters on seawater decontamination from crude oil by use of flexible silica aerogel. To this goal, methyltrimethoxysilane (MTMS) based silica aerogels were prepared by two-step acid-base catalyzed sol-gel process, involving ambient pressure drying (APD) method. To investigate the effects of sol-gel parameters, the aerogels were prepared under two different acidic and basic pH values (i.e. 4 and 8) and varied ethanol/MTMS molar ratios from 5 to 15. The adsorption capacity of the prepared aerogels was evaluated for two heavy and light commercial crude oils under multiple adsorption-desorption cycles. To reduce process time, desorption cycles were carried out by using roll milling for the first time. At optimum condition, silica aerogels are able to uptake heavy and light crude oils with the order of 16.7 and 13.7, respectively. Copyright © 2017 Elsevier Ltd. All rights reserved.
Okumura, Sumie; Okumura, Tetsu; Ishimatsu, Shinichi; Miura, Kunihisa; Maekawa, Hiroshi; Naito, Toshio
2005-01-01
Determine the effectiveness of decontamination, and perform thorough dry or wet decontamination, depending on the circumstances. Always remain cognizant of the fact that, even after decontamination has been completed, contamination may not have been completely eliminated. Perform periodic monitoring to determine whether secondary exposure has occurred in health care workers; if it appears that secondary exposure has occurred, then the PPE level must be increased and attempts must be made to identify and eliminate the source of the contamination. Finally, if the victims were exposed through ingestion, then consider the possibility that secondary exposure will occur during gastric lavage. PMID:16137390
Decontamination in a Russian settlement.
Fogh, C L; Andersson, K G; Barkovsky, A N; Mishine, A S; Ponamarjov, A V; Ramzaev, V P; Roed, J
1999-04-01
Decontamination was carried out in an area with three houses in Novo Bobovichi, Bryansk region, Russia, in the autumn of 1995. It was demonstrated that significant reductions in the dose rate both indoor (DRF = 0.34) and outdoor (DRF = 0.20) can be achieved when a controlled cleaning is undertaken. This paper describes the decontamination work carried out and the results obtained. The roofs of the houses were swept and cleaned by special roof cleaning equipment. The soil around the houses was removed by hand while carefully monitoring the ground for residual contamination. By monitoring the decline in the dose rate during the different stages of the work the dose reducing effect of each action has been measured.
Contactless decontamination of hair samples: cannabinoids.
Restolho, José; Barroso, Mário; Saramago, Benilde; Dias, Mário; Afonso, Carlos A M
2017-02-01
Room temperature ionic liquids (ILs) have already been shown to provide efficient extraction media for several systems, and to capture volatile compounds, namely opiates. In this work, a novel, contactless, artefact-free extraction procedure for the removal of Δ 9 -tetrahrydrocannabinol (THC) from the surface of human hair is presented. To prepare in vitro cannabinoids-contaminated hair, samples were flushed with hashish smoke for 7 h. The decontamination experiments were carried at 100 °C for 24 h, according to the procedure previously described. Fifty-three ILs were screened and presented decontamination efficiencies ranging from 0 to 96 %. Although the majority of the ILs presented efficiencies above 90%, the 1-ethanol-3-methyl tetrafluoroborate (96%) was chosen for further process optimization. The Design of Experiments results demonstrated that all studied variables were significant for the process and the obtained optimum conditions were: 100 °C, 13 h and 175 mg of IL. In the work of Perrotin-Brunel et al. (J. Mol. Struct. 2011, 987, 67), it is demonstrated that, at 100 °C, full conversion of tetrahydrocannabinolic acid (THCA) into THC is obtained after 60 min. Since our decontamination takes place over 13 h at 100 °C, full conversion of THCA into THC is expected. Additionally, our method was compared with the method proposed by Cairns et al. (Forensic Sci. Int. 2004, 145, 97), through the analysis of 15 in vitro contaminated hair samples. The results demonstrated that with our method a mean extraction efficiency of 11 % higher was obtained. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Buhr, T L; Young, A A; Bensman, M; Minter, Z A; Kennihan, N L; Johnson, C A; Bohmke, M D; Borgers-Klonkowski, E; Osborn, E B; Avila, S D; Theys, A M G; Jackson, P J
2016-04-01
To develop test methods and evaluate survival of Bacillus thuringiensis kurstaki cry(-) HD-1 and B. thuringiensis Al Hakam spores after exposure to hot, humid air inside of a C-130 aircraft. Bacillus thuringiensis spores were either pre-inoculated on 1 × 2 or 2 × 2 cm substrates or aerosolized inside the cargo hold of a C-130 and allowed to dry. Dirty, complex surfaces (10 × 10 cm) swabbed after spore dispersal showed a deposition of 8-10 log10 m(-2) through the entire cargo hold. After hot, humid air decontamination at 75-80°C, 70-90% relative humidity for 7 days, 87 of 98 test swabs covering 0·98 m(2) , showed complete spore inactivation. There was a total of 1·67 log10 live CFU detected in 11 of the test swabs. Spore inactivation in the 98 test swabs was measured at 7·06 log10 m(-2) . Laboratory test methods for hot, humid air decontamination were scaled for a large-scale aircraft field test. The C-130 field test demonstrated that hot, humid air can be successfully used to decontaminate an aircraft. Transition of a new technology from research and development to acquisition at a Technology Readiness Level 7 is unprecedented. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.
Management of Contaminated Autologous Grafts in Plastic Surgery
Centeno, Robert F; Desai, Ankit R; Watson, Marla E
2008-01-01
Background: Contamination of autologous grafts unfortunately occurs in plastic surgery, but the literature provides no guidance for management of such incidents. Methods: American Society of Aesthetic Plastic Surgery members were asked to complete an online survey that asked about the number and causes of graft contaminations experienced, how surgeons dealt with the problem, the clinical outcomes, and patient disclosure. Results: Nineteen hundred surgeons were asked to participate in the survey, and 223 responded. Of these, 70% had experienced at least 1 graft contamination incident, with 26% experiencing 4 or more. The most frequently reported reason for graft contamination was a graft falling on the floor (reported by 75%). Nearly two thirds of the contaminated grafts related to craniofacial procedures. Ninety-four percent of grafts were managed with decontamination and completion of the operation. The most common method of decontamination was washing with povidone-iodine, but this practice is contrary to recommendations in the literature. Only 3 surgeons (1.9%) said a clinical infection developed following decontaminated graft use. Patients were not informed in 60% of graft contamination incidents. The survey results and review of the literature led to development of algorithms for the management of inadvertent graft contamination and patient disclosure. Conclusions: Although autologous grafts do become contaminated in plastic surgery, the overwhelming majority can be safely decontaminated and produce minimal or no clinical sequelae. The algorithms presented are intended to serve as guides for prevention of contamination events or for their management should they occur. PMID:18496583
Laser ablation system, and method of decontaminating surfaces
Ferguson, Russell L.; Edelson, Martin C.; Pang, Ho-ming
1998-07-14
A laser ablation system comprising a laser head providing a laser output; a flexible fiber optic cable optically coupled to the laser output and transmitting laser light; an output optics assembly including a nozzle through which laser light passes; an exhaust tube in communication with the nozzle; and a blower generating a vacuum on the exhaust tube. A method of decontaminating a surface comprising the following steps: providing an acousto-optic, Q-switched Nd:YAG laser light ablation system having a fiber optically coupled output optics assembly; and operating the laser light ablation system to produce an irradiance greater than 1.times.10.sup.7 W/cm.sup.2, and a pulse width between 80 and 170 ns.
Evaluation of time required for water-only decontamination of an oil-based agent.
Moffett, Peter M; Baker, Benjamin L; Kang, Christopher S; Johnson, Melinda S
2010-03-01
The objective was to evaluate the time to decontaminate an area of skin exposed to an oil-based agent using a water-only decontamination protocol. A fluorescent mock chemical/biological agent was created. Each of 20 subjects had his/her forearm sprayed with the agent. Each subject placed his/her arm under a decontamination shower, which provided water at a pressure of 60-70 psi and 35 degrees C. After 30 sec a black light was used by three evaluators to determine whether the agent was removed. The process of 30 sec decontamination and re-evaluation was repeated for a total of 5 min. The primary endpoint was proportion decontaminated over time. After 90 sec, 100% of subjects were decontaminated. Whereas the data suggest the possibility of rapid water-only decontamination, the applicability of this data in current form is doubtful, but provides a model as a basis for future study.
Harrison, Tyler R; Muhamad, Jessica Wendorf; Yang, Fan; Morgan, Susan E; Talavera, Ed; Caban-Martinez, Alberto; Kobetz, Erin
2018-04-01
Firefighters are exposed to carcinogens such as volatile organic compounds (VOCs) and polycyclic aromatic hydrocarbons (PAHs) during fires and from their personal protective equipment (PPE). Recent research has shown that decontamination processes can reduce contamination on both gear and skin. While firefighter cultures that honor dirty gear are changing, little is known about current attitudes and behaviors toward decontamination in the fire service. Four hundred eighty-five firefighters from four departments completed surveys about their attitudes, beliefs, perceived norms, barriers, and behaviors toward post-fire decontamination processes. Overall, firefighters reported positive attitudes, beliefs, and perceived norms about decontamination, but showering after a fire was the only decontamination process that occurred regularly, with field decontamination, use of cleansing wipes, routine gear cleaning, and other behaviors all occurring less frequently. Firefighters reported time and concerns over wet gear as barriers to decontamination.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ribas, Antonio G.S.; Abrao, Alcidio
1970-05-15
This paper describes the studies of decontamination of thorium present as impurity in uranyl nitrate solutions, which was carried out through strong cationic resin where the thorium was partially retained. Then, the final decontamination was performed percolating the uranyl solution on a second cationic resin, after complexation of thorium (and other impurities) with EDTA. The thorium decontamination and the uranium retention were studied as a function of EDTA/U ratio, uranium concentration and acidity of the influent uranyl nitrate. The elution conditions were also studied as a function of eluent flow rate, concentration and acidity. Several tables and graphs showing themore » final results are included. (tr-auth)« less
2007-06-27
Selected CB Defense Systems SHAPESENSE Joint Warning and Reporting Network JSLIST CB Protected Shelter Joint Vaccine Acquisition Program Joint Effects...military can operate in any environment, unconstrained by chemical or biological weapons. 21 SHIELD SUSTAIN Selected CB Defense Systems SHAPESENSE Joint...28070625_JCBRN_Conference_Reeves UNCLASSIFIED Decontamination Vision Strippable Barriers Self-Decontaminating Fabrics/Coatings Reduce Logistics Burden
Smithwick, R W; Stratigos, C B; David, H L
1975-01-01
A method is presented for the decontamination, liquefaction, and concentration of sputum specimens that are in transport more than 24 h. The method is inexpensive, and culture results compare well with those obtained with the accepted N-acetyl-L-cysteine and sodium hydroxide method for the isolation of tubercle bacilli. The working solution, 1% cetylpyridinium chloride and 2% sodium chloride, is mixed in equal volumes with sputum before the specimens are shipped. Tubercle bacilli remained viable after 8 days of exposure to this solution. Only Lowenstein-Jensen medium was used because the cetylpyridinium chloride in the inoculum remains active on 7H10 or other agar base media and partially inhibits the growth of tubercle bacilli. PMID:809478
Hidaka, Tomoo; Kakamu, Takeyasu; Hayakawa, Takehito; Kumagai, Tomohiro; Jinnouchi, Takanobu; Sato, Sei; Tsuji, Masayoshi; Nakano, Shinichi; Koyama, Kikuo; Fukushima, Tetsuhito
2016-01-01
Objectives: To reveal the effect of age and other factors on perceived anxiety over radiation exposure among decontamination workers in Fukushima Prefecture, Japan. Methods: A survey questionnaire was sent to 1505 workers, with questions regarding age, presence of a written employment contract, previous residence, radiation passbook ownership, presence of close persons for consultation, knowledge of how to access public assistance, and a four-point scale of radiation-related anxiety (1= "Very much," 2= "Somewhat," 3= "A little bit," and 4= "None" ). The relationships between the degree of anxiety and variables were analyzed using the chi-square test and residual analysis. Results: In all, 512 participants responded to the questionnaire. The mean age of participants was 46.2 years (SD: 13.1, range: 18-77). Of them, 50, 233, 168, and 61 workers chose "Very much," "Somewhat," "A little bit," and "None," respectively, on the anxiety scale. Chi-square test showed that participants aged 61 years and over had higher degrees of anxiety (p<0.001). Ordinal logistic regression showed that the degree of anxiety increased if they did not have a written contract (p=0.042) or persons to consult (p=0.034) and if they routinely checked the dose rate (p=0.046). Conclusions: Decontamination workers who do not have a written contract or who are in socially isolated situations have greater anxiety over radiation exposure. Thus, it is important to both create supportive human relationships for consultation and enhance labor management in individual companies. PMID:27010088
Axmann, Sonja; Kolar, Veronika; Adler, Andreas; Strnad, Irmengard
2017-11-01
Salmonella can enter animal stocks via feedstuffs, thus posing not only an infection risk for animals, but also threatening to contaminate food of animal origin and finally humans. Salmonella contamination in feedstuffs is still a recurring and serious issue in animal production (especially for the poultry sector), and is regularly detected upon self-monitoring by feed companies (self-checks) and official inspections authorities. Operators within the feed chain in certain cases need to use hygienic condition enhancers, such as organic acids, to improve the quality of feed for animal nutrition, providing additional guarantees for the protection of animal and public health. The present study investigated the efficiencies of five organic acid preparations. The acid products were added to three different feed materials contaminated with Salmonella (contamination occurred by recontamination in the course of the production process) at seven different inclusion rates (1-7%) and analysed after 1, 2, and 7 days' exposure time using culture method (tenfold analysis). A reliable standard was established for defining a successful decontamination under the prevailing test conditions: 10 Salmonella-negative results out of 10 tested samples (0/10: i.e. 0 positive samples and 10 negative samples). The results demonstrated that the tested preparations showed significant differences with regard to the reduction in Salmonella contamination. At an inclusion rate of 7% of the feed materials, two out of five acid preparations showed an insufficient, very small, decontamination effect, whereas two others had a relatively large partial effect. Reliable decontamination was demonstrated only for one acid preparation, however, subject to the use of the highest acid concentration.
Treatment of radioactive liquid waste by sorption on natural zeolite in Turkey.
Osmanlioglu, Ahmet Erdal
2006-09-01
Liquid radioactive waste has been generated from the use of radioactive materials in industrial applications, research and medicine in Turkey. Natural zeolites (clinoptilolite) have been studied for the removal of several key radionuclides ((137)Cs, (60)Co, (90)Sr and (110m)Ag) from liquid radioactive waste. The aim of the present study is to investigate effectiveness of zeolite treatment on decontamination factor (DF) in a combined process (chemical precipitation and adsorption) at the laboratory tests and scale up to the waste treatment plant. In this study, sorption and precipitation techniques were adapted to decontamination of liquid low level waste (LLW). Effective decontamination was achieved when sorbents are used during the chemical precipitation. Natural zeolite samples were taken from different zeolite formations in Turkey. Comparison of the ion-exchange properties of zeolite minerals from different formations shows that Gordes clinoptilolite was the most suitable natural sorbent for radionuclides under dynamic treatment conditions and as an additive for chemical precipitation process. Clinoptilolite were shown to have a high selectivity for (137)Cs and (110m)Ag as sorbent. In the absence of potassium ions, native clinoptilolite removed (60)Co and (90)Sr very effectively from the liquid waste. In the end of this liquid waste treatment, decontamination factor was provided as 430 by using 0.5 mm clinoptilolite at 30 degrees C.
NASA Astrophysics Data System (ADS)
Gryczka, Urszula; Migdał, Wojciech; Bułka, Sylwester
2018-02-01
The effectiveness of the radiation decontamination process was tested for electron beam of energy 200 keV and 300 keV. The energy of electrons was controlled by the measurements of its penetration ability in stack of B3 dosimetric film. In the presented work, the reduction of total aerobic bacteria count was observed, depending on time of irradiation for samples of dried black pepper, onion flakes and bay leaves. The results were compared with the effect observed for the process where high energy electron beam was used.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Trovato, S.A.; Parry, J.O.
1995-03-01
Key to the safe and efficient operation of the nation`s civilian nuclear power plants is the performance of maintenance activities within regulations and guidelines for personnel radiation exposure. However, maintenance activities, often performed in areas of relatively high radiation fields, will increase as the nation`s plant age. With the Nuclear Regulatory Commission (NRC) lowering the allowable radiation exposure to plant workers in 1994 and considering further reductions and regulations in the future, it is imperative that new techniques be developed and applied to reduce personnel exposure. Full primary system chemical decontamination technology offers the potential to be single most effectivemore » method of maintaining workers exposure {open_quotes}as low as reasonably achievable{close_quotes} (ALARA) while greatly reducing plant operation and maintenance (O&M) costs. A three-phase program underway since 1987, has as its goal to demonstrate that full RCS decontamination is a visible technology to reduce general plant radiation levels without threatening the long term reliability and operability of a plant. This paper discusses research leading to and plans for a National Demonstration of Full RCS Chemical Decontamination at Indian Point 2 nuclear generating station in 1995.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Peters, T. B.; Fink, S. D.
Strip Effluent Hold Tank (SEHT), Decontaminated Salt Solution Hold Tank (DSSHT), and Caustic Wash Tank (CWT) samples from several of the ?microbatches? of Integrated Salt Disposition Project (ISDP) Salt Batch (?Macrobatch?) 4 have been analyzed for {sup 238}Pu, {sup 90}Sr, {sup 137}Cs, and by inductively-coupled plasma emission spectroscopy (ICPES). Furthermore, samples from the CWT have been analyzed by a variety of methods to investigate a decline in the decontamination factor (DF) of the cesium observed at MCU. The results indicate good decontamination performance within process design expectations. While the data set is sparse, the results of this set and themore » previous set of results for Macrobatch 3 samples indicate generally consistent operations. There is no indication of a disruption in plutonium and strontium removal. The average cesium DF and concentration factor (CF) for samples obtained from Macrobatch 4 are slightly lower than for Macrobatch 3, but still well within operating parameters. The DSSHT samples show continued presence of titanium, likely from leaching of the monosodium titanate in Actinide Removal Process (ARP).« less
Price, E; Weaver, G; Hoffman, P; Jones, M; Gilks, J; O'Brien, V; Ridgway, G
2016-03-01
A variety of methods are in use for decontaminating breast pump milk collection kits and related items associated with infant feeding. This paper aims to provide best practice guidance for decontamination of this equipment at home and in hospital. It has been compiled by a Joint Working Group of the Healthcare Infection Society and the Infection Prevention Society. The guidance has been informed by a search of the literature in Medline, the British Nursing Index, the Cumulative Index to Nursing and Allied Health Literature, Midwifery and Infant Care, and the results of two surveys of UK neonatal units in 2002/3 and 2006, and of members of the Infection Prevention Society in 2014. Since limited good quality evidence was available from these sources, much of the guidance represents good practice based on the consensus view of the Working Group. This guidance provides practical recommendations to support the safe decontamination of breast pump milk collection kits for healthcare professionals to use and communicate to other groups such as parents and carers. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.
Häggström, Mikael; Spira, Jack; Edelstam, Greta
2015-02-01
To determine whether current hygiene practices are appropriate during sonographic examinations. Five major hospitals in Sweden were investigated with a survey. At each hospital, the departments corresponding to the main types of sonographic examination were chosen. Personnel who were responsible for or acquainted with the local hygiene procedures completed a standardardized questionnaire. The surveys were completed by 25 departments, where the total number of sonographic examinations was approximately 20,000 per month. For transvaginal and transrectal sonographic examinations, the most common method for decontamination of the transducer was barrier protection during the procedure followed by cleansing with alcohol. Latex was the predominant cover material, but one department used polyethylene gloves, and another department used nitrile gloves. Both of these involved transvaginal ultrasonography. In transcutaneous examinations, all hospitals were using alcohol and paper or cloth for decontamination at a minimum. Transesophageal examinations were carried out without barrier protection, and decontamination was performed with an alkylating substance. The hygiene practices appear to be appropriate at most hospitals, but there is a prevalence of transducer cover materials of unacceptable permeability, as well as use of gloves on transducers despite insufficient evidence of safety. © 2015 Wiley Periodicals, Inc.
2011-09-01
low‐cost, lightweight, single‐use individual product for field self ‐decontamination. Surface (skin) decontamination of Bacillus subtilis spores has...field spray decontamination unit was previously demonstrated in 2003 at Guantanamo Bay, Cuba (Dankert, 2003), and for wound healing with repeated...Technology on plastics, rubber and plastic tubing, and clothing. Demonstrate ability of CleanseFx to function as skin cleanser in military setting
Cao, Yachao; Hui, Xiaoying; Zhu, Hanjiang; Elmahdy, Akram; Maibach, Howard
2018-07-01
This study compared the efficiency for in vitro human skin decontamination using DDGel and RSDL. Experiments were performed using in vitro human skin models, in which skin was mounted onto Flow-Through diffusion cells. The mass of 14 -C CEES removed from skin surface after decontamination was quantitated by measuring radioactivity with a liquid scintillation spectrometer. Both decontaminants removed more than 82% of CEES from skin. DDGel skin decontamination significantly reduced toxicant amount when compared to RSDL. Mean CEES remaining in stratum corneum (SC), viable epidermis, dermis, and systemic absorption of DDGel and RSDL were, 0.12 and 0.55% (P < 0.01), 0.31 and 0.95% (p < 0.01), 1.08 and 2.92% (p < 0.05), 3.13 and 6.34% (p < 0.05), respectively. DDGel showed higher decontamination efficiency (twice decontamination efficacy factor, DEF) than RSDL and efficiently removed chemicals from the skin surface, importantly back-extracted from the SC, and significantly reduced both chemical penetration into skin and systemic absorption. Thus, DDGel can offer a potential as a next generation skin decontamination platform technology for military and civilian applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Price, E; Weaver, G; Hoffman, P; Jones, M; Gilks, J; O'Brien, V; Ridgway, G
2016-03-01
A variety of methods are in use for decontaminating breast pump milk collection kits and related items associated with infant feeding. This paper aims to provide best practice guidance for decontamination of this equipment at home and in hospital. It has been compiled by a joint Working Group of the Healthcare Infection Society and the Infection Prevention Society. The guidance has been informed by a search of the literature in Medline, the British Nursing Index, the Cumulative Index to Nursing & Allied Health Literature, Midwifery & Infant Care and the results of two surveys of UK neonatal units in 2002/3 and 2006, and of members of the Infection Prevention Society in 2014. Since limited good quality evidence was available from these sources much of the guidance represents good practice based on the consensus view of the Working Group. Breast pump milk collection kits should not be reused by different mothers unless they have been sterilized in a Sterile Services Department between these different users.When used by the same mother, a detergent wash followed by thorough rinsing and drying after each use gives acceptable decontamination for most circumstances, as long as it is performed correctly.Additional decontamination precautions to washing, rinsing and drying may be used if indicated by local risk assessments and on advice from the departmental clinicians and Infection Prevention and Control Teams. The microbiological quality of the rinse water is an important consideration, particularly for infants on neonatal units.If bottle brushes or breast/nipple shields are used, they should be for use by one mother only. Decontamination should be by the processes used for breast pump milk collection kits.Dummies (soothers, pacifiers or comforters) needed for non-nutritive sucking by infants on neonatal units, should be for single infant use. Manufacturers should provide these dummies ready-to-use and individually packaged. They must be discarded at least every 24 hours or immediately if soiled with anything other than the baby's saliva. No attempt should be made to decontaminate the dummies, either before or during use. This guidance provides practical recommendations to support the safe decontamination of breast pump milk collection kits for healthcare professionals to use and communicate to other groups such as parents and carers.
Decontamination of chemical tracers in droplets by a submerging thin film flow
NASA Astrophysics Data System (ADS)
Landel, Julien R.; McEvoy, Harry; Dalziel, Stuart B.
2016-11-01
We investigate the decontamination of chemical tracers contained in small viscous drops by a submerging falling film. This problem has applications in the decontamination of hazardous chemicals, following accidental releases or terrorist attacks. Toxic droplets lying on surfaces are cleaned by spraying a liquid decontaminant over the surface. The decontaminant film submerges the droplets, without detaching them, in order to neutralize toxic chemicals in the droplets. The decontamination process is controlled by advection, diffusion and reaction processes near the drop-film interface. Chemical tracers dissolve into the film flow forming a thin diffusive boundary layer at the interface. The chemical tracers are then neutralized through a reaction with a chemical decontaminant transported in the film. We assume in this work that the decontamination process occurs mainly in the film phase owing to low solubility of the decontaminant in the drop phase. We analyze the impact of the reaction time scale, assuming first-order reaction, in relation with the characteristic advection and diffusion time scales in the case of a single droplet. Using theoretical, numerical and experimental means, we find that the reaction time scale need to be significantly smaller than the characteristic time scale in the diffusive boundary layer in order to enhance noticeably the decontamination of a single toxic droplet. We discuss these results in the more general case of the decontamination of a large number of droplets. This material is based upon work supported by the Defense Threat Reduction Agency under Contract No. HDTRA1-12-D-0003-0001.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Danilovich, Alexey; Ivanov, Oleg; Potapov, Victor
2013-07-01
Application of remote sensing methods using a spectrometric collimated system allows obtaining information about features of a formation of radiation fields in contaminated premises. This information helps in a preparation of a phased plan for dismantling of contaminated equipment. When the survey of technological premises of the research reactor at the Russian Research Centre 'Kurchatov institute' was conducted the remote controlled collimated spectrometric system was used. With its help the scanning of surveyed premises were carried out. As a result of this work, the distribution pattern of radionuclides activity was restored. The simulation of decontamination works was carried out andmore » maps of the distribution of activity and dose rate for surveyed premises were plotted and superimposed on its photo for situations before and after decontamination. The use of obtained results will allow significantly reduce radiation dose for staff at work on dismantling. (authors)« less
NASA Astrophysics Data System (ADS)
Machala, Z.; Jedlovský, I.; Chládeková, L.; Pongrác, B.; Giertl, D.; Janda, M.; Ikurová, L. Å.; Polčic, P.
2009-08-01
Three types of DC electrical discharges in atmospheric air (streamer corona, transient spark and glow discharge) were tested for bio-decontamination of bacteria and yeasts in water solution, and spores on surfaces. Static vs. flowing treatment of contaminated water were compared, in the latter the flowing water either covered the grounded electrode or passed through the high voltage needle electrode. The bacteria were killed most efficiently in the flowing regime by transient spark. Streamer corona was efficient when the treated medium flew through the active corona region. The spores on plastic foil and paper surfaces were successfully inactivated by negative corona. The microbes were handled and their population evaluated by standard microbiology cultivation procedures. The emission spectroscopy of the discharges and TBARS (thiobarbituric acid reactive substances) absorption spectrometric detection of the products of lipid peroxidation of bacterial cell membranes indicated a major role of radicals and reactive oxygen species among the bio-decontamination mechanisms.
40 CFR 170.150 - Decontamination.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Decontamination. 170.150 Section 170... PROTECTION STANDARD Standard for Workers § 170.150 Decontamination. (a)(1) Requirement. The agricultural employer must provide decontamination supplies for workers in accordance with this section whenever: (i...
Horby, P.; Murray, V.; Cummins, A.; Mackway-Jones, K.; Euripidou, R.
2000-01-01
Objectives—To evaluate the capability of accident and emergency (A&E) departments in six health regions of England to safely decontaminate casualties exposed to hazardous chemicals. Methods—In January 1999 a postal questionnaire was sent to the clinical director of all A&E departments in Trent, North and South Thames, South and West, North West and, Anglia and Oxford Health Regions. The questionnaire inquired about characteristics of the department, decontamination facilities and equipment, and staff training. Non-responders were sent a second questionnaire and contacted by telephone if they failed to respond to the second mailing. Results—308 of 326 departments identified (94%) returned a questionnaire. There was no significant difference in response rate by region (p = 0.99). Analysis was restricted to 154 major departments seeing more than 20 000 new attendances per year. Of these 154 departments, 109 (71%) had a written chemical incident plan but only 55 (36%) maintained a list of nearby industrial chemical sites. Fifty nine departments (38%) stated that members of staff had received training in the management of chemically contaminated casualties in the preceding year. Eighteen departments (12%) possessed the level of personal protective equipment (PPE) recommended for decontamination by the Ambulance Services Association. Ninety six departments (62%) had a designated decontamination room but only seven (7%) of them incorporated all the features generally considered necessary for safe decontamination. Forty one units (27%) had the capability to decontaminate casualties outside of the department either with warm water from a shower attachment or with a mobile decontamination unit. Thirty six departments (23%) had neither a decontamination room nor the ability to decontaminate casualties outside the department. Only 16 units (10%) had both adequate PPE and either a decontamination room or the capability to decontaminate outside the department. Conclusions—This study has identified deficiencies in the current NHS capability to respond to chemical incidents. To resolve this, nationally recognised standards for decontamination facilities, equipment and training should be formulated, agreed and implemented. PMID:11005405
Disinfectants used for environmental disinfection and new room decontamination technology.
Rutala, William A; Weber, David J
2013-05-01
Environmental contamination plays an important role in the transmission of several key health care-associated pathogens. Effective and thorough cleaning/disinfecting of the patient environment is essential. Room decontamination units (such as ultraviolet-C and hydrogen peroxide systems) aid in reducing environmental contamination after terminal room cleaning and disinfection. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.
Evaluation of the Effects of Hydrogen Peroxide on Common Aviation Structural Materials
2009-12-01
population of Geobacillus stearothermophilus . Once the sanitization/ decontamination phase is completed, the enclosure is 1 VHP is a registered...disinfection and/or decon- tamination technologies available, vaporized hydrogen peroxide (VHP)1 is of particular interest because it can be rapidly sterilized ...decontamination Unit (STERIS Corporation, Mentor, OH, USA) using VAPROX®2 as the sterilant in an enclosed chamber for 1, 10, or 25 VHP cycles . The exposure
2009-02-01
Chemical Biological Center (ECBC) to take advantage of ECBC’s extensive expertise and specialized research facilities for the decontamination of surfaces...Agency (EPA) established an Interagency Agreement with the U.S. Army Edgewood Chemical Biological Center (ECBC) to take advantage of ECBC’s extensive...Detector (Waters Corporation, Milford, MA). Conductivity suppression was carried out using an ERIS 1000HP Autosuppressor ( Alltech Corporation, Deerfield
Hamilton, Murray G; Hill, Ira; Conley, John; Sawyer, Thomas W; Caneva, Duane C; Lundy, Paul M
2004-11-01
O-ethyl S-(2-diisopropylaminoethyl) methylphosphonothioate (VX) is an extremely toxic organophosphate nerve agent that has been weaponized and stockpiled in a number of different countries, and it has been used in recent terrorist events. It differs from other well-known organophosphate nerve agents in that its primary use is as a contact poison rather than as an inhalation hazard. For this reason, we examined the effects of application site and skin decontamination on VX toxicity in anesthetized domestic swine after topical application. VX applied to the surface of the ear rapidly resulted in signs of toxicity consistent with the development of cholinergic crisis, including apnea and death. VX on the epigastrium resulted in a marked delayed development of toxic signs, reduced toxicity, and reduction in the rate of cholinesterase depression compared with animals exposed on the ear. Skin decontamination (15 minutes post-VX on the ear) arrested the development of clinical signs and prevented further cholinesterase inhibition and death. These results confirm earlier work that demonstrates the importance of exposure site on the resultant toxicity of this agent and they also show that decontamination postexposure has the potential to be an integral and extremely important component of medical countermeasures against this agent.
Development of a Persistent Chemical Agent Simulator System (PCASS)
NASA Technical Reports Server (NTRS)
Mcginness, W. G.
1983-01-01
The development of a persistent chemical agent simulation system (PCASS) is described. This PCASS is to be used for the military training of troops to simulate actual chemical warfare. The purpose of this system is to facilitate in the determination of chemical contamination and effectiveness of decontamination for training purposes. The fluorescent tracer employed has no daylight activation, but yet is easily removed with a decontaminate solution or water and surfactants. Also employed is a time delayed color developing system. When an individual is subjected to the PCASS and does not decontaminate adequately, red blotches or red coloration will develop as a function of time and temperature. The intent of this is to simulate the delayed chemical reaction of mustard contaminates.
Biofilm on the tracheoesophageal voice prosthesis: considerations for oral decontamination.
Somogyi-Ganss, Eszter; Chambers, Mark S; Lewin, Jan S; Tarrand, Jeffrey J; Hutcheson, Katherine A
2017-01-01
The tracheoesophageal puncture (TEP) restores verbal communication after total laryngectomy using a one-way valved voice prosthesis (VP). Microbial colonization can shorten VP device life. Our aims were to investigate patterns of prosthetic and oral colonization, and record changes in VP device life after targeted decontamination. We conducted a retrospective review of TEP clinic patients who underwent microbial analysis of the VP between 01/2003 and 07/2013. Two subgroups were analyzed: (1) patients with microbial analysis of the VP and the mouth were analyzed to identify patterns of common contamination, and (2) patients who were prescribed targeted oral decontamination on the basis of the microbial analysis of the VP were analyzed to evaluate effects on device life. Among 42 patients, 3 patients had only fungal, 5 only bacterial, and 33 had polyspecies fungal and bacterial colonization. In the TEP-oral microflora subgroup (n = 15), 7 had common microorganisms in the mouth and on the VP. Among the decontamination subgroup (n = 23), 6 patients received broad spectrum rinse, 16 antifungal agents and 13 antibiotics, or a combination thereof. After targeted decontamination, the median device life of prostheses improved from 7.89 to 10.82 weeks (p = 0.260). The majority of patients with a suboptimal VP device life in this pilot had polyspecies bacterial and fungal colonization. VPs rarely had fungal contamination alone (3 %), and non-albicans fungal species were more common than expected. For these reasons, we are exploring the use of targeted decontamination regimens that were associated with 1.4-fold improvement in VP duration.
Applying Crowd Psychology to Develop Recommendations for the Management of Mass Decontamination
Drury, John; Rubin, G. James; Williams, Richard; Amlôt, Richard
2015-01-01
Mass decontamination is a public health intervention employed by emergency responders following a chemical, biological, or radiological release. It involves a crowd of people whose interactions with each other and with the emergency responders managing the incident are likely to affect the success of the decontamination process. The way in which members of the public collectively experience decontamination is likely to affect their behavior and hence is crucial to the success of the decontamination process. Consequently, responders and the responsible authorities need to understand crowd psychology during mass emergencies and disasters. Recently, the social identity approach to crowd psychology has been applied to explain public perceptions and behavior during mass emergencies. This approach emphasizes that crowd events are characteristically intergroup encounters, in which the behavior of one group can affect the perceptions and behavior of another. We summarize the results from a program of research in which the social identity approach was applied to develop and test recommendations for the management of mass decontamination. The findings from this program of research show that (1) responders' perceptions of crowd behavior matter; (2) participants value greater communication and this affects their compliance; and (3) social identity processes explain the relationship between effective responder communication and relevant outcome variables, such as public compliance, public cooperation, and public anxiety. Based on this program of research, we recommend 4 responder management strategies that focus on increasing public compliance, increasing orderly and cooperative behavior among members of the public, reducing public anxiety, and respecting public needs for privacy. PMID:25812428
Applying crowd psychology to develop recommendations for the management of mass decontamination.
Carter, Holly; Drury, John; Rubin, G James; Williams, Richard; Amlôt, Richard
2015-01-01
Mass decontamination is a public health intervention employed by emergency responders following a chemical, biological, or radiological release. It involves a crowd of people whose interactions with each other and with the emergency responders managing the incident are likely to affect the success of the decontamination process. The way in which members of the public collectively experience decontamination is likely to affect their behavior and hence is crucial to the success of the decontamination process. Consequently, responders and the responsible authorities need to understand crowd psychology during mass emergencies and disasters. Recently, the social identity approach to crowd psychology has been applied to explain public perceptions and behavior during mass emergencies. This approach emphasizes that crowd events are characteristically intergroup encounters, in which the behavior of one group can affect the perceptions and behavior of another. We summarize the results from a program of research in which the social identity approach was applied to develop and test recommendations for the management of mass decontamination. The findings from this program of research show that (1) responders' perceptions of crowd behavior matter; (2) participants value greater communication and this affects their compliance; and (3) social identity processes explain the relationship between effective responder communication and relevant outcome variables, such as public compliance, public cooperation, and public anxiety. Based on this program of research, we recommend 4 responder management strategies that focus on increasing public compliance, increasing orderly and cooperative behavior among members of the public, reducing public anxiety, and respecting public needs for privacy.
NASA Astrophysics Data System (ADS)
Pottage, Thomas; Walker, James; Bennett, Allan; Vrublevskis, John; Hovland, Scott
This study, funded by the European Space Agency (ESA) and undertaken by the Health Protec-tion Agency, UK supported by Systems Engineering and Assessment Ltd., was devised to select suitable current decontamination technologies for development for future manned missions to the Moon and Mars. There is a requirement to decontaminate the habitat module due to the concerns about astronaut ill health, microbial deterioration of materials and potential forward contamination in the case of Mars. In the case of the MIR space station, biodeterioration of components and materials occurred, and dangerous levels of airborne microorganisms were detected during air sampling procedures which lead to the introduction of microbial exposure limits (as MORD SSP 50260) to ensure the health of the crew. COSPAR planetary protection guidelines highlight the need to reduce any potential forward or backwards contamination issues that may occur through the use of Extra Vehicular Activity (EVA) suits whilst on Mars. Decontamination of the suit exterior must be completed before any EVA activity on Mars, whilst a further decontamination cycle must be completed after entry to the airlock following EVA. Technologies and techniques have also been investigated for the microbial reduction of the interior surfaces of the EVA suit to stop biodeterioration of the materials and protect the user from pathogenic microbe accumulation. The first work package reviewed the systems description and requirements as detailed in the statement of work. The requirements were broken down into 12 further requirement sections, where they were updated and expanded, resulted in Technical Note (TN) 1 which was then used as the base document for WP2 and WP3. WP2 investigated the current technologies available for the decontamination of the habitat module interior on missions of up to 6 months and missions that have durations of greater than 6 months. A comprehensive review was carried out for the different methods that could be employed singularly and in combination to decontaminate the habitat. From this review a trade off matrix was compiled scoring each technology on a determined set of parameters. The highest score indicated the most suitable technology. For missions up to 6 months surface cleaning using disinfectant wipes were recommended in combination with an air disinfection/filtration system. For missions greater than 6 months these techniques would be complemented by the addition of a gaseous decontamination system, which could be periodically used to reduce microbial load from inaccessible surfaces. WP3 reviewed the current technologies that could be used for the decontamination of the EVA suit, both external surfaces (after use on the Lunar and Martian surfaces) and internal surfaces. Trade off matrices were constructed to reflect the new parameters for these uses. Only physical decontamination of the exterior surface of the EVA suit is needed for Lunar mission, but for Martian missions this must be enhanced with a gaseous disinfection technology. The interior of the suit can be decontaminated using passive antimicrobial fabrics and active cleaning using disinfectant wipes. WP4 summarised the previous TNs, and included estimates of costs and timelines for the development, based on technology readiness levels, of technologies that need to be flight proven before use on a mission.
ACCUMULATION OF RADIOACTIVE STRONTIUM BY HYDROPHYTES AND DETRITUS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Agre, A.L.; Telitchenko, M.M.
1963-11-01
Uptake and accumulation of Sr/sup 90/ was studied in several species of green algae, blue-green algae, diatoms, mosses, and in duckweed. The organdisms were placed in experimental solutions made of standing tap water into which Sr/ sup 90/ was introduced as SrCl/sub 2/. Activity of the solutions was 10/sup -8/ to 10/sup -6/ Curie per liter. Radioactivity of the organisms was determined every 25 days on a B unit with an SI-2B leadshielded end-window counter according to standard method. The values of the coefficients of Sr/sup 90/ accumulation by the hydrophytes were found to be inversely proportional to the isotopicmore » concentration of the medium. Algae had higher Sr/sup 90/ accumulation coefficients than did mosses, an the accumulation in algae was more rapid. Experiments showed that organic wastes effected 80% decontamination of the solutions, on the average. It is suggested that hydrophytes and organic wastes may consequently be used for decontamination of water containing Sr/sup 90/. (H.M.G.)« less
NASA Astrophysics Data System (ADS)
Kishimoto, A.; Kataoka, J.; Nishiyama, T.; Fujita, T.; Takeuchi, K.; Okochi, H.; Ogata, H.; Kuroshima, H.; Ohsuka, S.; Nakamura, S.; Hirayanagi, M.; Adachi, S.; Uchiyama, T.; Suzuki, H.
2014-11-01
After the nuclear disaster in Fukushima, radiation decontamination has become particularly urgent. To help identify radiation hotspots and ensure effective decontamination operation, we have developed a novel Compton camera based on Ce-doped Gd3Al2Ga3O12 scintillators and multi-pixel photon counter (MPPC) arrays. Even though its sensitivity is several times better than that of other cameras being tested in Fukushima, we introduce a depth-of-interaction (DOI) method to further improve the angular resolution. For gamma rays, the DOI information, in addition to 2-D position, is obtained by measuring the pulse-height ratio of the MPPC arrays coupled to ends of the scintillator. We present the detailed performance and results of various field tests conducted in Fukushima with the prototype 2-D and DOI Compton cameras. Moreover, we demonstrate stereo measurement of gamma rays that enables measurement of not only direction but also approximate distance to radioactive hotspots.
Biochar-based nano-composites for the decontamination of wastewater: A review.
Tan, Xiao-Fei; Liu, Yun-Guo; Gu, Yan-Ling; Xu, Yan; Zeng, Guang-Ming; Hu, Xin-Jiang; Liu, Shao-Bo; Wang, Xin; Liu, Si-Mian; Li, Jiang
2016-07-01
Synthesizing biochar-based nano-composites can obtain new composites and combine the advantages of biochar with nano-materials. The resulting composites usually exhibit great improvement in functional groups, pore properties, surface active sites, catalytic degradation ability and easy to separation. These composites have excellent abilities to adsorb a range of contaminants from aqueous solutions. Particularly, catalytic material-coated biochar can exert simultaneous adsorption and catalytic degradation function for organic contaminants removal. Synthesizing biochar-based nano-composites has become an important practice for expanding the environmental applications of biochar and nanotechnology. This paper aims to review and summarize the various synthesis techniques for biochar-based nano-composites and their effects on the decontamination of wastewater. The characteristic and advantages of existing synthesis methods are summarized and discussed. Application of biochar-based nano-composites for different contaminants removal and the underlying mechanisms are reviewed. Furthermore, knowledge gaps that exist in the fabrication and application of biochar-based nano-composites are also identified. Copyright © 2016 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Milyutin, V.V.; Gelis, V.M.; Penzin, R.A.
1995-12-31
In this paper the results obtained in field tests of decontaminating radioactive natural and industrial solutions of different chemical and radionuclide composition from cesium and strontium radionuclides are reported. Decontamination of industrial reservoir water at the Production Association Mayak (Chelyabinsk Region, Russia) was performed using CMP synthetic zeolite. Efficient decontamination of the feed water is achieved after preliminary precipitation of hardness salts in the form of carbonates. Decontamination of water from the pool for spent fuel element storage from {sup 137}Cs was conducted using NGA ferricyanide sorbent. Decontamination factors with respect to {sup 137}Cs of 400 have been reached, themore » installation throughput being 100,000 by (bed volumes). Decontamination of liquid radwaste at Murmansk Shipping Co was conducted with CFB, CMP synthetic zeolites and NGA ferricyanide sorbent as well. Decontamination of D and D solutions and wastes of the special laundry resulted in decontamination factors within the range of 20--400, 10--100, and 10--30 with respect to {sup 137}Cs, {sup 90}Sr, and total {beta}-activity, respectively. Installation throughput of 3,000--5,000 bv for zeolites and 8,000--10,000 bv for ferrocyanide sorbents has been reached. Results obtained prove the high efficiency of sorption technique for decontaminating solutions from cesium and strontium radionuclides.« less
2011-01-01
Introduction Mechanically ventilated critically ill patients frequently develop ventilator-associated pneumonia (VAP), a life-threatening complication. Proposed preventive measures against VAP include, but are not restricted to, selective decontamination of the digestive tract (SDD), selective oropharyngeal decontamination (SOD) and the use of probiotics. Probiotics are live bacteria that could have beneficial effects on the host by altering gastrointestinal flora. Similar to SDD and SOD, a prescription of probiotics aims at the prevention of secondary colonization of the upper and/or lower digestive tract. Methods We performed a literature review to describe the differences and similarities between SDD/SOD and probiotic preventive strategies, focusing on (a) efficacy, (b) risks, and (c) the routing of these strategies. Results Reductions in the incidence of VAP have been achieved with SDD and SOD. Two large randomized controlled trials even showed reduced mortality with these preventive strategies. Randomized controlled trials of probiotic strategies also showed a reduction of the incidence of VAP, but trials were too small to draw firm conclusions. Preventive strategies with antibiotics and probiotics may be limited due to the risk of emerging resistance to the locally applied antibiotics and the risk of probiotic-related infections, respectively. The majority of trials of SDD and SOD did not exhaustively address the issue of emerging resistance. Likewise, trials of probiotic strategies did not adequately address the risk of colonization with probiotics and probiotic-related infection. In studies of SDD and SOD the preventive strategy aimed at decontamination of the oral cavity, throat, stomach and intestines, and the oral cavity and throat, respectively. In the vast majority of studies of probiotic therapy the preventive strategy aimed at decontamination of the stomach and intestines. Conclusions Prophylactic use of antibiotics in critically ill patients is effective in reducing the incidence of VAP. Probiotic strategies deserve consideration in future well-powered trials. Future studies are needed to determine if preventive antibiotic and probiotic strategies are safe with regard to development of antibiotic resistance and probiotic infections. It should be determined whether the efficacy of probiotics improves when these agents are provided to the mouth and the intestines simultaneously. PMID:21232110
46 CFR 154.1410 - Decontamination shower.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Decontamination shower. 154.1410 Section 154.1410... Equipment § 154.1410 Decontamination shower. When Table 4 references this section, a vessel carrying the listed cargo must have a decontamination shower and an eye wash that: (a) Are on the weatherdeck; and (b...
46 CFR 154.1410 - Decontamination shower.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Decontamination shower. 154.1410 Section 154.1410... Equipment § 154.1410 Decontamination shower. When Table 4 references this section, a vessel carrying the listed cargo must have a decontamination shower and an eye wash that: (a) Are on the weatherdeck; and (b...
Daneman, Nick; Sarwar, Syed; Fowler, Robert A; Cuthbertson, Brian H
2013-04-01
Many meta-analyses have shown reductions in infection rates and mortality associated with the use of selective digestive decontamination (SDD) or selective oropharyngeal decontamination (SOD) in intensive care units (ICUs). These interventions have not been widely implemented because of concerns that their use could lead to the development of antimicrobial resistance in pathogens. We aimed to assess the effect of SDD and SOD on antimicrobial resistance rates in patients in ICUs. We did a systematic review of the effect of SDD and SOD on the rates of colonisation or infection with antimicrobial-resistant pathogens in patients who were critically ill. We searched for studies using Medline, Embase, and Cochrane databases, with no limits by language, date of publication, study design, or study quality. We included all studies of selective decontamination that involved prophylactic application of topical non-absorbable antimicrobials to the stomach or oropharynx of patients in ICUs, with or without additional systemic antimicrobials. We excluded studies of interventions that used only antiseptic or biocide agents such as chlorhexidine, unless antimicrobials were also included in the regimen. We used the Mantel-Haenszel model with random effects to calculate pooled odds ratios. We analysed 64 unique studies of SDD and SOD in ICUs, of which 47 were randomised controlled trials and 35 included data for the detection of antimicrobial resistance. When comparing data for patients in intervention groups (those who received SDD or SOD) versus data for those in control groups (who received no intervention), we identified no difference in the prevalence of colonisation or infection with Gram-positive antimicrobial-resistant pathogens of interest, including meticillin-resistant Staphylococcus aureus (odds ratio 1·46, 95% CI 0·90-2·37) and vancomycin-resistant enterococci (0·63, 0·39-1·02). Among Gram-negative bacilli, we detected no difference in aminoglycoside-resistance (0·73, 0·51-1·05) or fluoroquinolone-resistance (0·52, 0·16-1·68), but we did detect a reduction in polymyxin-resistant Gram-negative bacilli (0·58, 0·46-0·72) and third-generation cephalosporin-resistant Gram-negative bacilli (0·33, 0·20-0·52) in recipients of selective decontamination compared with those who received no intervention. We detected no relation between the use of SDD or SOD and the development of antimicrobial-resistance in pathogens in patients in the ICU, suggesting that the perceived risk of long-term harm related to selective decontamination cannot be justified by available data. However, our study indicates that the effect of decontamination on ICU-level antimicrobial resistance rates is understudied. We recommend that future research includes a non-crossover, cluster randomised controlled trial to assess long-term ICU-level changes in resistance rates. None. Copyright © 2013 Elsevier Ltd. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Iijima, K.; Funaki, H.; Tokizawa, T.
In decontamination pilot projects conducted by Japan Atomic Energy Agency (JAEA), many different techniques were tested to determine their applicability to remediate areas evacuated after the Fukushima Daiichi nuclear accident following the Great Tohoku earthquake and tsunami of March 11, 2011. In addition to buildings, roads and farmland, the forest adjacent to living areas was one of the main decontamination targets. The projects evaluated the radioactive contamination of trees and the effectiveness of decontaminating a highly contaminated evergreen forest. This forest was located 1.3 km southwest of the Fukushima Daiichi Nuclear Power Plant and is dominated by Japanese cedar treesmore » and fir trees. As the first step, three Japanese cedar trees and three fir trees were cut down and the distributions of radioactive cesium (Cs) were measured in each. The total concentrations of {sup 134}Cs and {sup 137}Cs in the leaves and branches were about 1 MBq/kg for both cedar and fir trees, and were appreciably higher than in the bark for cedar. The concentrations in the outer part of the trunks (under the bark) were lower, on the order of 10 kBq/kg, and those in the core of the trunks were lower than 1 kBq/kg for both kinds of trees. The observation that the Cs concentrations are higher in the outer part of trees, is compatible with the assumption that radio-Cs was mostly adsorbed on the surface of trees and partly penetrated into the trunks through the bark. Evolution of air dose rates in a 100 x 60 m pasture adjacent to the forest was monitored during decontamination of the forest and of the pasture itself. The dose rates in the pasture decreased drastically after stripping contaminated topsoil from the pasture and decreased slightly more after stripping contaminated topsoil of the forest floor and pruning the trees. Cutting down and removing 84 trees in the outermost area (10- m width) of the forest also slightly decreased these dose rates. After decontamination, the residual dose rates around the highly contaminated forest were mostly attributed to radioactive Cs existing in or on trees and topsoil in the untouched forest beyond the decontaminated area. (authors)« less
Apparatus and method for simultaneous recovery of hydrogen from water and from hydrocarbons
Willms, R. Scott; Birdsell, Stephen A.
2000-01-01
Apparatus and method for simultaneous recovery of hydrogen from water and from hydrocarbon feed material. The feed material is caused to flow over a heated catalyst which fosters the water-gas shift reaction (H.sub.2 O+COH.sub.2 +CO.sub.2) and the methane steam reforming reaction (CH.sub.4 +H.sub.2 O3 H.sub.2 +CO). Both of these reactions proceed only to partial completion. However, by use of a Pd/Ag membrane which is exclusively permeable to hydrogen isotopes in the vicinity of the above reactions and by maintaining a vacuum on the permeate side of the membrane, product hydrogen isotopes are removed and the reactions are caused to proceed further toward completion. A two-stage palladium membrane reactor was tested with a feed composition of 28% CQ.sub.4, 35% Q.sub.2 O (where Q=H, D, or T), and 31% Ar in 31 hours of continuous operation during which 4.5 g of tritium were processed. Decontamination factors were found to increase with decreasing inlet rate. The first stage was observed to have a decontamination factor of approximately 200, while the second stage had a decontamination factor of 2.9.times.10.sup.6. The overall decontamination factor was 5.8.times.10.sup.8. When a Pt/.alpha.-Al.sub.2 O.sub.3 catalyst is employed, decoking could be performed without catalyst degradation. However, by adjusting the carbon to oxygen ratio of the feed material with the addition of oxygen, coking could be altogether avoided.
Isobe, Tomonori; Mori, Yutaro; Takada, Kenta; Sato, Eisuke; Takahashi, Hideki; Sekiguchi, Takao; Yoshimura, Yousuke; Sakurai, Hideyuki; Sakae, Takeji
2013-10-01
A large amount of radioactive material was released into the atmosphere after the accident of the Fukushima Daiichi Nuclear Power Plant following the Tohoku earthquake on 11 March 2011, and traces of these materials were detected in Tsukuba. Because radioactive materials can adhere to vegetables, the authors made a qualitative evaluation of vegetables in Tsukuba, estimated internal exposure dose based on quantitative measurement results, and investigated several decontamination methods. Qualitative analysis of vegetable contamination was done by autoradiography. Quantitative analysis was done using a high-purity germanium detector. To assess decontamination, two methods were tested: one with running water and the other with boiling water. In addition, boiled soup stock was measured. In the qualitative evaluation by autoradiography, radioactive materials were not uniformly distributed but adhered to vegetables in clumps and hot spots. In the quantitative evaluation to measure contamination of outer and inner leaves of sanchu lettuce, it was observed that the concentration of I was 8,031.35 ± 764.79 Bq kg in the outer leaves and 115.28 ± 20.63 Bq kg in the inner leaves. In addition, the concentration of Cs was 1,371.93 ± 366.45 Bq kg in the outer leaves and 9.68 ± 15.03 Bq kg in the inner leaves. This suggests that one can greatly reduce internal exposure dose by removing the outer leaves if one has to eat vegetables just after a nuclear accident. In the decontamination assessment, a decontamination efficiency of up to 70% was achieved by boiling vegetables for 20 min.
Developments in Decontamination Technologies of Military Personnel and Equipment
NASA Astrophysics Data System (ADS)
Sata, Utkarsh R.; Ramkumar, Seshadri S.
Individual protection is important for warfighters, first responders and civilians to meet the current threat of toxic chemicals and chemical warfare (CW) agents. Within the realm of individual protection, decontamination of warfare agents is not only required on the battlefield but also in laboratory, pilot plants, production and agent destruction sites. It is of high importance to evaluate various decontaminants and decontamination techniques for implementing the best practices in varying scenarios such as decontamination of personnel, sites and sensitive equipment.
Gon Ryu, Sam; Wan Lee, Hae
2015-01-01
The nerve agent, O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (VX) must be promptly eliminated following its release into the environment because it is extremely toxic, can cause death within a few minutes after exposure, acts through direct skin contact as well as inhalation, and persists in the environment for several weeks after release. A mixture of hydrogen peroxide vapor and ammonia gas was examined as a decontaminant for the removal of VX on solid surfaces at ambient temperature, and the reaction products were analyzed by gas chromatography-mass spectrometry (GC-MS) and nuclear magnetic resonance spectrometry (NMR). All the VX on glass wool filter disks was found to be eliminated after 2 h of exposure to the decontaminant mixtures, and the primary decomposition product was determined to be non-toxic ethyl methylphosphonic acid (EMPA); no toxic S-[2-(diisopropylamino)ethyl] methylphosphonothioic acid (EA-2192), which is usually produced in traditional basic hydrolysis systems, was found to be formed. However, other by-products, such as toxic O-ethyl S-vinyl methylphosphonothioate and (2-diisopropylaminoethyl) vinyl disulfide, were detected up to 150 min of exposure to the decontaminant mixture; these by-products disappeared after 3 h. The two detected vinyl byproducts were identified first in this study with the decontamination system of liquid VX on solid surfaces using a mixture of hydrogen peroxide vapor and ammonia gas. The detailed decontamination reaction networks of VX on solid surfaces produced by the mixture of hydrogen peroxide vapor and ammonia gas were suggested based on the reaction products. These findings suggest that the mixture of hydrogen peroxide vapor and ammonia gas investigated in this study is an efficient decontaminant mixture for the removal of VX on solid surfaces at ambient temperature despite the formation of a toxic by-product in the reaction process.
NASA Astrophysics Data System (ADS)
Choi, Ho-Gil; Shim, Moonsoo; Lee, Jong-Hyeon; Yi, Kyung-Woo
2017-09-01
The waste salt treatment process is required for the reuse of purified salts, and for the disposal of the fission products contained in waste salt during pyroprocessing. As an alternative to existing fission product separation methods, the horizontal zone refining process is used in this study for the purification of waste salt. In order to evaluate the purification ability of the process, three-dimensional simulation is conducted, considering heat transfer, melt flow, and mass transfer. Impurity distributions and decontamination factors are calculated as a function of the heater traverse rate, by applying a subroutine and the equilibrium segregation coefficient derived from the effective segregation coefficients. For multipass cases, 1d solutions and the effective segregation coefficient obtained from three-dimensional simulation are used. In the present study, the topic is not dealing with crystal growth, but the numerical technique used is nearly the same since the zone refining technique was just introduced in the treatment of waste salt from nuclear power industry because of its merit of simplicity and refining ability. So this study can show a new application of single crystal growth techniques to other fields, by taking advantage of the zone refining multipass possibility. The final goal is to achieve the same high degree of decontamination in the waste salt as in zone freezing (or reverse Bridgman) method.
NASA Astrophysics Data System (ADS)
Gillespie, Jonathan B.; Maclean, Michelle; Wilson, Mark P.; Given, Martin J.; MacGregor, Scott J.
2017-03-01
This study details the design, build and testing of a prototype antimicrobial blended white light unit containing pulsed red, yellow, green and 405nm LEDs. With a push for alternative methods of disinfection, optical methods have become a topic of interest. Ultra-violet (UV) light is widely known for its antimicrobial properties however; 405nm light has demonstrated significant antimicrobial properties against many common hospital acquired pathogens. In this study, a pulsed, blended, white-light prototype with a high content of 405 nm antimicrobial light, was designed, built and tested. Antimicrobial efficacy testing of the prototype was conducted using Staphylococcus aureus and Pseudomonas. aeruginosa, two bacteria which are common causes of hospital acquired infections. These were exposure to 3 different light outputs from the prototype and the surviving bacteria enumerated. Results showed that the mixed light output provided a much better CRI and light output under which to work. Also, the light output containing 405 nm light provided an antimicrobial effect, with decontamination of 103 CFUml-1 populations of both bacterial species. The other light content (red, yellow, green) had no beneficial or adverse effects on the antimicrobial properties of the 405nm light. The results suggest that with further development, it could be possible to produce an antimicrobial blended white light containing pulsed 405nm light that could supplement or even replace standard white lighting in certain environments.
Results of chemical decontamination of DOE`s uranium-enrichment scrap metal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levesque, R.G.
1997-02-01
The CORPEX{reg_sign} Nuclear Decontamination Processes were used to decontaminate representative scrap metal specimens obtained from the existing scrap metal piles located at the Department of Energy (DOE) Portsmouth Gaseous Diffusion Plant (PORTS), Piketon, Ohio. In September 1995, under contract to Lockheed Martin Energy Systems, MELE Associates, Inc. performed the on-site decontamination demonstration. The decontamination demonstration proved that significant amounts of the existing DOE scrap metal can be decontaminated to levels where the scrap metal could be economically released by DOE for beneficial reuse. This simple and environmentally friendly process can be used as an alternative, or in addition to, smeltingmore » radiologically contaminated scrap metal.« less
Decontamination of mass casualties--re-evaluating existing dogma.
Levitin, Howard W; Siegelson, Henry J; Dickinson, Stanley; Halpern, Pinchas; Haraguchi, Yoshikura; Nocera, Anthony; Turineck, David
2003-01-01
The events of 11 September 2001 became the catalyst for many to shift their disaster preparedness efforts towards mass-casualty incidents. Emergency responders, healthcare workers, emergency managers, and public health officials worldwide are being tasked to improve their readiness by acquiring equipment, providing training and implementing policy, especially in the area of mass-casualty decontamination. Accomplishing each of these tasks requires good information, which is lacking. Management of the incident scene and the approach to victim care varies throughout the world and is based more on dogma than scientific data. In order to plan effectively for and to manage a chemical, mass-casualty event, we must critically assess the criteria upon which we base our response. This paper reviews current standards surrounding the response to a release of hazardous materials that results in massive numbers of exposed human survivors. In addition, a significant effort is made to prepare an international perspective on this response. Preparations for the 24-hour threat of exposure of a community to hazardous material are a community responsibility for first-responders and the hospital. Preparations for a mass-casualty event related to a terrorist attack are a governmental responsibility. Reshaping response protocols and decontamination needs on the differences between vapor and liquid chemical threats can enable local responders to effectively manage a chemical attack resulting in mass casualties. Ensuring that hospitals have adequate resources and training to mount an effective decontamination response in a rapid manner is essential.
Wendling, Morgan; Richter, William; Lastivka, Andrew; Mickelsen, Leroy
2016-01-01
The primary goal of this study was to determine the conditions required for the effective inactivation of Bacillus anthracis spores on materials by using methyl bromide (MeBr) gas. Another objective was to obtain comparative decontamination efficacy data with three avirulent microorganisms to assess their potential for use as surrogates for B. anthracis Ames. Decontamination tests were conducted with spores of B. anthracis Ames and Geobacillus stearothermophilus, B. anthracis NNR1Δ1, and B. anthracis Sterne inoculated onto six different materials. Experimental variables included temperature, relative humidity (RH), MeBr concentration, and contact time. MeBr was found to be an effective decontaminant under a number of conditions. This study highlights the important role that RH has when fumigation is performed with MeBr. There were no tests in which a ≥6-log10 reduction (LR) of B. anthracis Ames was achieved on all materials when fumigation was done at 45% RH. At 75% RH, an increase in the temperature, the MeBr concentration, or contact time generally improved the efficacy of fumigation with MeBr. This study provides new information for the effective use of MeBr at temperatures and RH levels lower than those that have been recommended previously. The study also provides data to assist with the selection of an avirulent surrogate for B. anthracis Ames spores when additional tests with MeBr are conducted. PMID:26801580
Schwartz, M D; Hurst, C G; Kirk, M A; Reedy, S J D; Braue, E H
2012-08-01
Rapid decontamination of the skin is the single most important action to prevent dermal absorption of chemical contaminants in persons exposed to chemical warfare agents (CWA) and toxic industrial chemicals (TICs) as a result of accidental or intentional release. Chemicals on the skin may be removed by mechanical means through the use of dry sorbents or water. Recent interest in decontamination systems which both partition contaminants away from the skin and actively neutralize the chemical has led to the development of several reactive decontamination solutions. This article will review the recently FDA-approved Reactive Skin Decontamination Lotion (RSDL) and will summarize the toxicity and efficacy studies conducted to date. Evidence of RSDL's superior performance against vesicant and organophosphorus chemical warfare agents compared to water, bleach, and dry sorbents, suggests that RSDL may have a role in mass human exposure chemical decontamination in both the military and civilian arenas.
Silver, G.L.
1980-09-24
The present invention provides a process for decontaminating a radioactive liquid containing a radioactive element capable of forming a hydroxide. This process includes the steps of contacting the radioactive liquid with a decontaminating composition and separating the resulting radioactive sludge from the resulting liquid. The decontaminating composition contains calcium cyanamide.
Hawkins, Steve A C; Simmons, Hugh A; Gough, Kevin C; Maddison, Ben C
2015-01-24
Scrapie of sheep/goats and chronic wasting disease of deer/elk are contagious prion diseases where environmental reservoirs are directly implicated in the transmission of disease. In this study, the effectiveness of recommended scrapie farm decontamination regimens was evaluated by a sheep bioassay using buildings naturally contaminated with scrapie. Pens within a farm building were treated with either 20,000 parts per million free chorine solution for one hour or were treated with the same but were followed by painting and full re-galvanisation or replacement of metalwork within the pen. Scrapie susceptible lambs of the PRNP genotype VRQ/VRQ were reared within these pens and their scrapie status was monitored by recto-anal mucosa-associated lymphoid tissue. All animals became infected over an 18-month period, even in the pen that had been subject to the most stringent decontamination process. These data suggest that recommended current guidelines for the decontamination of farm buildings following outbreaks of scrapie do little to reduce the titre of infectious scrapie material and that environmental recontamination could also be an issue associated with these premises. British Veterinary Association.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, K.D.
2006-07-01
Nuclear facility decontamination, dismantlement, and demolition activities provide a myriad of challenges along the path to reaching a safe, effective, and compliant decommissioning. Among the challenges faced during decommissioning, is the constant management and technical effort to eliminate, mitigate, or minimize the potential of risks of radiation exposures and other hazards to the worker, the surrounding community, and the environment. Management strategies to eliminate, mitigate, or minimize risks include incorporating strong safety and As Low As Reasonably Achievable (ALARA) principles into an integrated work planning process. Technical and operational strategies may include utilizing predictive risk analysis tools to establish contaminationmore » limits for demolition and using remote handling equipment to reduce occupational and radiation exposures to workers. ECC and E2 Closure Services, LLC (Closure Services) have effectively utilized these management and technical tools to eliminate, mitigate, and reduce radiation exposures under contract to the U.S. Department of Energy (DOE) for the decontamination and decommissioning Columbus Closure Project (CCP). In particular, Closure Services achieved significant dose reduction during the dismantling, decontamination, and demolition activities for Building JN-1. Management strategies during the interior dismantlement, decontamination, and demolition of the facility demanded an integrated work planning processes that involved project disciplines. Integrated planning processes identified multiple opportunities to incorporate the use of remote handling equipment during the interior dismantling and demolition activities within areas of high radiation. Technical strategies employed predictive risk analysis tools to set upper bounding contamination limits, allowed for the radiological demolition of the building without exceeding administrative dose limits to the worker, general public, and the environment. Adhering to management and technical strategies during the dismantlement, decontamination, and demolition of Building JN-1 enabled Closure Services to achieve strong ALARA performance, maintain absolute compliance under the regulatory requirements and meeting licensing conditions for decommissioning. (authors)« less
The therapeutic use of localized cooling in the treatment of VX poisoning.
Sawyer, T W; Mikler, J; Worek, F; Reiter, G; Thiermann, H; Tenn, C; Weatherby, K; Bohnert, S
2011-07-04
The organophosphate (OP) nerve agent VX is a weaponized chemical warfare agent that has also been used by terrorists against civilians. This contact poison produces characteristic signs of OP poisoning, including miosis, salivation, mastication, dysrhythmias and respiratory distress prior to death. Although successful treatment of OP poisoning can be obtained through decontamination and/or oxime reactivation of agent-inhibited cholinesterase, medical countermeasures that increase the therapeutic window for these measures would be of benefit. An anaesthetized swine model was utilized to examine the effects of lethal VX exposure to the skin, followed by cooling the exposure site prior to decontamination or treatment. The cooling was simply accomplished by using crushed ice in grip-seal plastic bags applied to the exposure sites. Cooling of skin exposed to lethal doses of VX significantly increased the window of opportunity for successful decontamination using the Reactive Skin Decontaminant Lotion(®) (RSDL(®)) or treatment with the oxime antidotes HI-6 and 2PAM. Analyses of blood VX levels showed that cooling acted to slow or prevent the entry of VX into the bloodstream from the skin. If the exposure site is known, the simple and non-invasive application of cooling provides a safe means with which to dramatically increase the therapeutic window in which decontamination and/or antidote treatment against VX are life-saving. Copyright © 2011. Published by Elsevier Ireland Ltd.
Petit, B M; Almeida, F C; Uchiyama, T R; Lopes, F O C; Tino, K H; Chewins, J
2017-10-01
An evaluation was made of the efficacy of 35% hydrogen peroxide vapour (HPV) against foot-and-mouth disease virus (FMDV) in a biosafety facility. Biological indicators (BIs) were produced using three serotypes of FMDV, all with a titre of ≥10 6 TCID 50 per ml. Fifteen BIs of each serotype were distributed across five locations, throughout a 30-m 3 airlock chamber, producing a total of 45 BIs. Thirty-five percent HPV was generated and applied using a Bioquell vaporization module located in the centre of the chamber. After a dwell period of 40 min, the HPV was removed via the enclosures air handling system and the BIs were collected. The surfaces of the BIs were recovered into Glasgow's modified Eagle's medium (GMEM), cultivated in BHK21 Cl13 cell culture and analysed for evidence of cytopathic effect (CPE). No CPE was detected in any BI sample. Positive controls showed CPE. The experimentation shows that FMDV is susceptible to HPV decontamination and presents a potential alternative to formaldehyde. Foot-and-mouth disease virus (FMDV) is an important pathogen in terms of biosafety due to its infectious nature and wide range of host animals, such as cattle, sheep, goats and pigs. Outbreaks of FMDV can have a severe impact on livestock production, causing morbidity, mortality, reduced yields and trade embargoes. Laboratories studying FMDV must possess BSL4 robust bio-decontamination methods to prevent inadvertent release. Formaldehyde has been the primary agent for environmental decontamination, but its designation as a human carcinogen has led to a search for alternatives. This study shows 35% hydrogen peroxide vapour has the potential to be a rapid, effective, residue-free alternative. © 2017 The Society for Applied Microbiology.
Omotade, T O; Bernhards, R C; Klimko, C P; Matthews, M E; Hill, A J; Hunter, M S; Webster, W M; Bozue, J A; Welkos, S L; Cote, C K
2014-12-01
Decontamination and remediation of a site contaminated by the accidental or intentional release of fully virulent Bacillus anthracis spores are difficult, costly and potentially damaging to the environment. Development of novel decontamination strategies that have minimal environmental impacts remains a high priority. Although ungerminated spores are amongst the most resilient organisms known, once exposed to germinants, the germinating spores, in some cases, become susceptible to antimicrobial environments. We evaluated the concept that once germinated, B. anthracis spores would be less hazardous and significantly easier to remediate than ungerminated dormant spores. Through in vitro germination and sensitivity assays, we demonstrated that upon germination, B. anthracis Ames spores and Bacillus thuringiensis Al Hakam spores (serving as a surrogate for B. anthracis) become susceptible to environmental stressors. The majority of these germinated B. anthracis and B. thuringiensis spores were nonviable after exposure to a defined minimal germination-inducing solution for prolonged periods of time. Additionally, we examined the impact of potential secondary disinfectant strategies including bleach, hydrogen peroxide, formaldehyde and artificial UV-A, UV-B and UV-C radiation, employed after a 60-min germination-induction step. Each secondary disinfectant employs a unique mechanism of killing; as a result, germination-induction strategies are better suited for some secondary disinfectants than others. These results provide evidence that the deployment of an optimal combination strategy of germination-induction/secondary disinfection may be a promising aspect of wide-area decontamination following a B. anthracis contamination event. By inducing spores to germinate, our data confirm that the resulting cells exhibit sensitivities that can be leveraged when paired with certain decontamination measures. This increased susceptibility could be exploited to devise more efficient and safe decontamination measures and may obviate the need for more stringent methods that are currently in place. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.
NASA Astrophysics Data System (ADS)
Bhat, Rajeev; Sridhar, K. R.; Karim, A. A.
2010-09-01
Lotus seeds are nutraceutically valued natural plant produce, which succumbs to microbial contamination, predominantly to toxigenic moulds. Results of the present study revealed seed coat portion to harbor higher proportion of microbial load, particularly fungi than cotyledon portion. Among the mycotoxins analyzed, aflatoxins (B 1, B 2, G 1 and G 2) were below detectable limits, while the seeds were devoid of Ochratoxin-A (OTA). Application of different doses of electron beam and gamma irradiation (0, 2.5, 5, 7.5, 10, 15 and 30 kGy) for decontamination purpose revealed significant dose-dependent decrease in the fungal contaminants ( P<0.05). However, the contaminant yeasts could survive up to 10 kGy dose, which could be completely eliminated at 15 kGy. From the results obtained, a dose range between 10 and 15 kGy is recommended for complete decontamination, as these doses have also been shown earlier to have minimal effects on nutritional and functional properties of lotus seeds.
Decontaminate feature for tracking: adaptive tracking via evolutionary feature subset
NASA Astrophysics Data System (ADS)
Liu, Qiaoyuan; Wang, Yuru; Yin, Minghao; Ren, Jinchang; Li, Ruizhi
2017-11-01
Although various visual tracking algorithms have been proposed in the last 2-3 decades, it remains a challenging problem for effective tracking with fast motion, deformation, occlusion, etc. Under complex tracking conditions, most tracking models are not discriminative and adaptive enough. When the combined feature vectors are inputted to the visual models, this may lead to redundancy causing low efficiency and ambiguity causing poor performance. An effective tracking algorithm is proposed to decontaminate features for each video sequence adaptively, where the visual modeling is treated as an optimization problem from the perspective of evolution. Every feature vector is compared to a biological individual and then decontaminated via classical evolutionary algorithms. With the optimized subsets of features, the "curse of dimensionality" has been avoided while the accuracy of the visual model has been improved. The proposed algorithm has been tested on several publicly available datasets with various tracking challenges and benchmarked with a number of state-of-the-art approaches. The comprehensive experiments have demonstrated the efficacy of the proposed methodology.
Raguse, Marina; Fiebrandt, Marcel; Stapelmann, Katharina; Madela, Kazimierz; Laue, Michael; Lackmann, Jan-Wilm; Thwaite, Joanne E.; Setlow, Peter; Awakowicz, Peter
2016-01-01
Novel decontamination technologies, including cold low-pressure plasma and blue light (400 nm), are promising alternatives to conventional surface decontamination methods. However, the standardization of the assessment of such sterilization processes remains to be accomplished. Bacterial endospores of the genera Bacillus and Geobacillus are frequently used as biological indicators (BIs) of sterility. Ensuring standardized and reproducible BIs for reliable testing procedures is a significant problem in industrial settings. In this study, an electrically driven spray deposition device was developed, allowing fast, reproducible, and homogeneous preparation of Bacillus subtilis 168 spore monolayers on glass surfaces. A detailed description of the structural design as well as the operating principle of the spraying device is given. The reproducible formation of spore monolayers of up to 5 × 107 spores per sample was verified by scanning electron microscopy. Surface inactivation studies revealed that monolayered spores were inactivated by UV-C (254 nm), low-pressure argon plasma (500 W, 10 Pa, 100 standard cubic cm per min), and blue light (400 nm) significantly faster than multilayered spores were. We have thus succeeded in the uniform preparation of reproducible, highly concentrated spore monolayers with the potential to generate BIs for a variety of nonpenetrating surface decontamination techniques. PMID:26801572
de Waal, Y C M; Raghoebar, G M; Meijer, H J A; Winkel, E G; van Winkelhoff, A J
2015-09-01
The objective of this randomized, double-blind, controlled trial was to evaluate the clinical, radiographic, and microbiological effects of implant surface decontamination with a 2% chlorhexidine (CHX) solution in comparison with a 0.12% chlorhexidine + 0.05% cetylpyridinium chloride (CPC) solution during resective surgical peri-implantitis treatment. Forty-four patients (108 implants) with peri-implantitis were treated with resective surgical treatment consisting of bone re-contouring, surface debridement and chemical decontamination, and apically repositioned flap. Patients were randomly allocated to decontamination with a 2% CHX solution (test group) or 0.12% CHX + 0.05% CPC (control group). Clinical and radiographic parameters were recorded before treatment (baseline), and at 3, 6, and 12 months after treatment. Microbiological parameters were recorded during surgery. Multilevel analysis showed no significant differences in bleeding, suppuration, probing pocket depth, and radiographic bone loss between control and test group over three follow-up measurements (3, 6, and 12 months) from baseline. Both decontamination procedures resulted in significant reductions in anaerobic bacterial counts on the implant surface, but no significant difference was noted between control and test group (mean log 3.37 ± 2.34 vs. 3.65 ± 2.87, P = 0.99). The use of a 2% CHX solution for implant surface decontamination during resective peri-implantitis therapy does not lead to improved clinical, radiographic, or microbiological results compared with a 0.12% CHX + 0.05% CPC solution. Overall, the additional use of CHX reduces anaerobic bacterial load on the implant surface better than mechanical debridement alone, but does not seem to enhance clinical treatment outcomes (ClinicalTrials.gov number NCT01852253). © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Radiocesium decontamination of a riverside in Fukushima, Japan.
Nishikiori, Tatsuhiro; Suzuki, Satoshi
2017-10-01
Extensive decontamination measures have been implemented in the area affected by the Fukushima Dai-ichi nuclear disaster. Typical decontamination measures, such as removing topsoil of several centimeters in depth, are not suitable for rivers where contaminated sediments have been deposited. A decontamination measure was tested that considered the spatial distribution of radiocesium at the lower part of a tributary of the Abukuma River in Fukushima. The radiocesium distribution in the flood channel was vertically and horizontally highly heterogeneous. In some parts, the activity concentration was high (>10 kBq/kg for 137 Cs) even at depths of 25 cm in the sediment. This may be due to plant growth in the flood channel favoring the deposition of sediment with high activity concentration. On the basis of the radiocesium distribution, the flood channel sediment was removed to a depth of 15-35 cm, which accumulated the most radiocesium (>3.0 kBq/kg for the sum of 134 Cs and 137 Cs). The upper 5 cm of soil was removed from the dike slopes. The river bed was not decontaminated because the activity concentration was low (<1 kBq/kg) in the river bed sediment and because the water shields gamma rays emitted from the sediment. The test decontamination measure reduced the air dose rate by a factor of approximately two, demonstrating the effectiveness of our measures. Annual external doses were calculated for when this part of the dike and the flood channel is used for commuting to school and outdoor education. The doses during the activities at the test site accounted for only 1-2% of the value during daily life in the surrounding area, indicating that radiation exposure during riverside activities is limited. Copyright © 2017 Elsevier Ltd. All rights reserved.
Casey, Anna L; Karpanen, Tarja J; Nightingale, Peter; Elliott, Tom S J
2018-01-01
The optimal decontamination method for needle-free connectors is still unresolved. The objective of this study was to determine if a continuous passive disinfection cap is as effective as standard cleaning for the microbial decontamination of injection ports of two types of needle-free connectors. The injection ports of needle-free connectors were inoculated with Staphylococcus aureus and allowed to dry. Disinfection caps containing 70% ( v / v ) isopropyl alcohol (IPA) were attached to the connectors for one, three or 7 days and were compared with needle-free connectors cleaned with 2% ( w / v ) chlorhexidine gluconate (CHG) in 70% ( v/v ) IPA. The number of S. aureus remaining on the injection ports was evaluated. Median log 10 reductions and 95% confidence interval (CI) were calculated and data analyzed using the Mann-Whitney test. The application of the disinfection cap resulted in a significantly higher reduction in S. aureus than the 2% ( w / v ) CHG in 70% ( v / v ) IPA wipe, achieving a > 5 Log 10 reduction in CFU at each time point. The disinfection caps resulted in a significantly higher reduction in S.aureus on the injection ports when compared to the use of a 2% ( w/v ) CHG in 70% ( v/v ) IPA wipe. This offers an explanation for the lower rates of central-line associated bloodstream infection (CLABSI) associated with the use of disinfection caps reported in clinical studies.
1982-08-01
results of changing selected independent variables. ri The results of the projection of chemical agent density and cloud drift, including dissapation and... combination of agent effects, creates, over time, an extensive threat to wide areas of the FBHA, according to current theories. Shifting wind patterns...will be proposed in paragraph 2.7. The selection of decontamination equipment by the study team is a result of a combination of factors. First, current
PWR steam generator chemical cleaning, Phase I. Final report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rothstein, S.
1978-07-01
United Nuclear Industries (UNI) entered into a subcontract with Consolidated Edison Company of New York (Con Ed) on August 8, 1977, for the purpose of developing methods to chemically clean the secondary side tube to tube support crevices of the steam generators of Indian Point Nos. 1 and 2 PWR plants. This document represents the first reporting on activities performed for Phase I of this effort. Specifically, this report contains the results of a literature search performed by UNI for the purpose of determining state-of-the-art chemical solvents and methods for decontaminating nuclear reactor steam generators. The results of the searchmore » sought to accomplish two objectives: (1) identify solvents beyond those proposed at present by UNI and Con Ed for the test program, and (2) confirm the appropriateness of solvents and methods of decontamination currently in use by UNI.« less
NASA Technical Reports Server (NTRS)
Kalfayan, S. H.
1972-01-01
Spacecraft sterilization is a vital factor in projects for the successful biological exploration of other planets. The microorganisms of major concern are the fungi and bacteria. Sterilization procedures are oriented toward the destruction of bacterial spores. Gaseous sterilants are examined, giving attention to formaldehyde, beta-propiolactone, ethylene oxide, and the chemistry of the bactericidal action of sterilants. Radiation has been seriously considered as another method for spacecraft sterilization. Dry heat sterilization is discussed together with the effects of ethylene oxide decontamination and dry heat sterilization on materials.
Study methods for disinfection water for injection
NASA Astrophysics Data System (ADS)
Grishkanich, Alexander; Zhevlakov, Alexander; Kascheev, Sergey; Polyakov, Vladimir; Sidorov, Igor; Ruzankina, Julia; Yakovlev, Alexey; Mak, Andrey
2016-04-01
Experimental results presented in this study tends to explore viruses in the water for their further decontamination under the influence of laser radiation (λ=220-390 nm). Conducted a series of experiments to study the dependence of water quality from the effects of laser radiation. Correlation between degree of survival of viruses and power density. The results showed that all the analyzed samples of water is clearing from bacteria to 98%. Preliminary tests of the prototype laboratory system UFOVI has opened up new opportunities for water sterilizing.
Development of a Complimentary Low Temperature Decontamination Technique for Spacecraft Materials
NASA Astrophysics Data System (ADS)
Pottage, Thomas; Bennett, Allan; Walker, James; Fowler, Chantal; Weber, Christina; Rohr, Thomas; Kminek, Gerhard
Dry heat microbial reduction (DHMR) is one of the current processes used to ensure that the microbial burden of a spacecraft lander meets the predetermined levels set out within the COSPAR policy regarding planetary protection. DHMR involves heating the craft or compo-nents to approximately 110-125C for over 6-30hrs, and was previously used to decontaminate the entire Viking lander spacecraft and parts of almost all other spacecrafts sent to Mars after-wards. This process, whilst proving effective and reproducible is not compatible with the some highly sensitive sensor and electronic components of a modern spacecraft. For these components an alternative method for low temperature decontamination needs to be identified. The Health Protection Agency, UK, investigated three gaseous decontamination technologies in a project funded by European Space Agency. These technologies consisted of two hydrogen peroxide technologies (Vapour Hydrogen Peroxide, Steris Inc. and Hydrogen Peroxide Vapour, Bioquell Ltd.) and one chlorine dioxide (ClorDiSys) system. The technologies were chosen after a comprehensive literature study identified them as the most suitable technologies for the decontamination process. An environmental chamber (20m3 ) was used as the test chamber to expose two commercially available biological indicators, three naturally occurring organisms chosen by ESA and a range of spacecraft materials to each of the technologies. The commercial biological indicators, Bacil-lus atrophaeus and Geobacillus sterothermophilus, were exposed to 3 varying concentrations of each of the technologies in order to attempt to achieve a 6-log reduction in recoverable organ-isms. After these results were obtained the most efficacious cycle was chosen for each technology and the naturally occurring organisms and materials to be tested were exposed to three cy-cles. Whilst the microbial enumeration was completed at the HPA, material compatibility was undertaken at ESTEC and residue analysis at the Rutherford Appleton Laboratories, UK. The results demonstrate that a concentration of approximately 1.1mg/l of hydrogen peroxide injected into the test chamber (35o C) is adequate to demonstrate a 6-log reduction in biological organism recovery for all of the 5 organisms tested over a 20 min period using the Steris generator. The final phase of the work is currently underway and will be incorporated into the final presentation.
Los, Agata; Ziuzina, Dana; Akkermans, Simen; Boehm, Daniela; Cullen, Patrick J; Van Impe, Jan; Bourke, Paula
2018-04-01
Contamination of cereal grains as a key global food resource with insects or microorganisms is a persistent concern for the grain industry due to irreversible damage to quality and safety characteristics and economic losses. Atmospheric cold plasma presents an alternative to conventional grain decontamination methods owing to the high antimicrobial potential of reactive species generated during the treatment, but effects against product specific microflora are required to understand how to optimally develop this approach for grains. This work investigated the influence of ACP processing parameters for both cereal grain decontamination and grain quality as important criteria for grain or seed use. A high voltage (HV) (80 kV) dielectric barrier discharge (DBD) closed system was used to assess the potential for control of native microflora and pathogenic bacterial and fungal challenge microorganisms, in tandem with effects on grain functional properties. Response surface modelling of experimental data probed the key factors in relation to microbial control and seed germination promotion. The maximal reductions of barley background microbiota were 2.4 and 2.1 log 10 CFU/g and of wheat - 1.5 and 2.5 log 10 CFU/g for bacteria and fungi, respectively, which required direct treatment for 20 min followed by a 24 h sealed post-treatment retention time. In the case of challenge organisms inoculated on barley grains, the highest resistance was observed for Bacillus atrophaeus endospores, which, regardless of retention time, were maximally reduced by 2.4 log 10 CFU/g after 20 min of direct treatment. The efficacy of the plasma treatment against selected microorganisms decreased in the following order: E. coli > P. verrucosum (spores) > B. atrophaeus (vegetative cells) > B. atrophaeus (endospores). The challenge microorganisms were more susceptible to ACP treatment than naturally present background microbiota. No major effect of short term plasma treatment on the retention of quality parameters was observed. Germination percentage measured after 7 days cultivation was similar for samples treated for up to 5 min, but this was decreased after 20 min of direct treatment. Overall, ACP proved effective for cereal grain decontamination, but it is noted that the diverse native micro-flora may pose greater resistance to the closed, surface decontamination approach than the individual fungal or bacterial challenges, which warrants investigation of grain microbiome responses to ACP. Copyright © 2018 Elsevier Ltd. All rights reserved.
Advanced remediation of uranium-contaminated soil.
Kim, S S; Han, G S; Kim, G N; Koo, D S; Kim, I G; Choi, J W
2016-11-01
The existing decontamination method using electrokinetic equipment after acidic washing for uranium-contaminated soil requires a long decontamination time and a significant amount of electric power. However, after soil washing, with a sulfuric acid solution and an oxidant at 65 °C, the removal of the muddy solution using a 100 mesh sieve can decrease the radioactivity of the remaining coarse soil to the clearance level. Therefore, only a small amount of fine soil collected from the muddy solution requires the electrokinetic process for its decontamination. Furthermore, it is found that the selective removal of uranium from the sulfuric washing solution is not obtained using an anion exchanger but rather using a cation exchanger, unexpectedly. More than 90% of the uranium in the soil washing solutions is adsorbed on the S-950 resin, and 87% of the uranium adsorbed on S-950 is desorbed by washing with a 0.5 M Na 2 CO 3 solution at 60 °C. Copyright © 2016 Elsevier Ltd. All rights reserved.
Evaluation of Commercially-Available Equipment for the ...
Report The Underground Transport Restoration (UTR) project is an inter-agency effort. This effort aims to improve the capability for transit systems to quickly and efficiently recover from a biological contamination incident by refining existing methods, tools and protocols for characterization, clean-up, and clearance of contamination in physical structures (i.e., tunnels, stations) and rolling stock (i.e., subway trains). The aim was to evaluate existing sampling, characterization, and decontamination technologies through experimentation, table-top exercises and operational demonstrations to develop guidance and decision frameworks and support tools through interactions of local, state and federal partners. In this investigation, a survey of commercially-available or fielded equipment was conducted and resulted in three pieces of identified equipment that could be used or rapidly modified for use in dispensing liquid chemicals to decontaminate surfaces following a biological contamination incident. documenting lab-scale testing, field-scale testing, and an equipment demonstration of commercial equipment used to decontaminate subway infrastructure following a biological incident.
Oostdijk, Evelien A N; de Wit, G A; Bakker, Marina; de Smet, Anne Marie G A; Bonten, M J M
2013-03-05
To determine costs and effects of selective digestive tract decontamination (SDD) and selective oropharyngeal decontamination (SOD) as compared with standard care (ie, no SDD/SOD (SC)) from a healthcare perspective in Dutch Intensive Care Units (ICUs). A post hoc analysis of a previously performed cluster-randomised trial (NEJM 2009;360:20). 13 Dutch ICUs. Patients with ICU-stay of >48 h that received SDD (n=2045), SOD (n=1904) or SC (n=1990). SDD or SOD. Effects were based on hospital survival, expressed as crude Life Years Gained (cLYG). The incremental cost-effectiveness ratio (ICER) was calculated, with corresponding cost acceptability curves. Sensitivity analyses were performed for discount rates, costs of SDD, SOD and mechanical ventilation. Total costs per patient were €41 941 for SC (95% CI €40 184 to €43 698), €40 433 for SOD (95% CI €38 838 to €42 029) and €41 183 for SOD (95% CI €39 408 to €42 958). SOD and SDD resulted in crude LYG of +0.04 and +0.25, respectively, as compared with SC, implying that both SDD and SOD are dominant (ie, cheaper and more beneficial) over SC. In cost-effectiveness acceptability curves probabilities for cost-effectiveness, compared with standard care, ranged from 89% to 93% for SOD and from 63% to 72% for SDD, for acceptable costs for 1 LYG ranging from €0 to €20 000. Sensitivity analysis for mechanical ventilation and discount rates did not change interpretation. Yet, if costs of the topical component of SDD and SOD would increase 40-fold to €400/day and €40/day (maximum values based on free market prices in 2012), the estimated ICER as compared with SC for SDD would be €21 590 per LYG. SOD would remain cost-saving. SDD and SOD were both effective and cost-saving in Dutch ICUs.
2011-01-01
Background The cleaning stage of the instrument decontamination process has come under increased scrutiny due to the increasing complexity of surgical instruments and the adverse affects of residual protein contamination on surgical instruments. Instruments used in the podiatry field have a complex surface topography and are exposed to a wide range of biological contamination. Currently, podiatry instruments are reprocessed locally within surgeries while national strategies are favouring a move toward reprocessing in central facilities. The aim of this study was to determine the efficacy of local and central reprocessing on podiatry instruments by measuring residual protein contamination of instruments reprocessed by both methods. Methods The residual protein of 189 instruments reprocessed centrally and 189 instruments reprocessed locally was determined using a fluorescent assay based on the reaction of proteins with o-phthaldialdehyde/sodium 2-mercaptoethanesulfonate. Results Residual protein was detected on 72% (n = 136) of instruments reprocessed centrally and 90% (n = 170) of instruments reprocessed locally. Significantly less protein (p < 0.001) was recovered from instruments reprocessed centrally (median 20.62 μg, range 0 - 5705 μg) than local reprocessing (median 111.9 μg, range 0 - 6344 μg). Conclusions Overall, the results show the superiority of central reprocessing for complex podiatry instruments when protein contamination is considered, though no significant difference was found in residual protein between local decontamination unit and central decontamination unit processes for Blacks files. Further research is needed to undertake qualitative identification of protein contamination to identify any cross contamination risks and a standard for acceptable residual protein contamination applicable to different instruments and specialities should be considered as a matter of urgency. PMID:21219613
Xu, Yunwei; Huang, Zhihong; Corner, George
2016-09-28
Corrosion of surgical instruments provides a seat for contamination and prevents proper sterilisation, placing both patients and medical staff at risk of infection. Corrosion can also compromise the structural integrity of instruments and lead to mechanical failure in use. It is essential to understand the various factors affecting corrosion resistance of surgical instruments and how it can be minimised.This paper investigates the effect on corrosion resistance from the clinical washing decontamination (WD) process, specifically by studying the changes in surface roughness and Cr/Fe ratio. Results indicate that the WD process provides a positive effect on smooth polished samples, while a lesser positive effect was observed on rough reflection reduced samples.
Infection control in intensive care units and prevention of ventilator-associated pneumonia.
Bonten, M J; Weinstein, R A
2000-12-01
Ventilator-associated pneumonia (VAP) is considered the most frequent infection in the intensive care unit (ICU), although incidence rates depend on the diagnostic methods. Because VAP has been associated with increased mortality and greater costs for medical care, prevention remains an important goal for intensive care medicine. Selective digestive decontamination (SDD), the most frequently studied method of infection prevention, is still controversial despite more than 30 prospective randomized trials and 6 metaanalyses. SDD reduces the incidence of VAP diagnoses, but beneficial effects on duration of ventilation or ICU stay, antibiotic use, and patient survival have not been shown unequivocally. Although recent metaanalyses suggest a 20% to 40% decrease in ICU mortality for SDD used with systemic prophylaxis, this benefit should be confirmed in a large, prospective, randomized study, preferably with a cost-benefit analysis. Selection of pathogens resistant to the antibiotics used in SDD remains the most important drawback of SDD, rendering SDD contraindicated in wards with endemic resistant problems. Other methods of infection prevention that do not create a selective growth advantage for resistant microorganisms may be more useful. Among these are the use of endotracheal tubes with the possibility of continuous aspiration of subglottic secretions, oropharyngeal decontamination with antiseptics, or the semirecumbent treatment position of patients. Although these methods were successful in single studies, more data are needed. Notwithstanding the potential benefits of these interventions, such classic infection control measures as handwashing remain the cornerstone of infection prevention.
Kumar, Vinod; Goel, Rajeev; Chawla, Raman; Silambarasan, M.; Sharma, Rakesh Kumar
2010-01-01
Chemical, biological, radiological, and nuclear (CBRN) decontamination is the removal of CBRN material from equipment or humans. The objective of the decontamination is to reduce radiation burden, salvage equipment, and materials, remove loose CBRN contaminants, and fix the remaining in place in preparation for protective storage or permanent disposal work activities. Decontamination may be carried out using chemical, electrochemical, and mechanical means. Like materials, humans may also be contaminated with CBRN contamination. Changes in cellular function can occur at lower radiation doses and exposure to chemicals. At high dose, cell death may take place. Therefore, decontamination of humans at the time of emergency while generating bare minimum waste is an enormous task requiring dedication of large number of personnel and large amount of time. General principles of CBRN decontamination are discussed in this review with emphasis on radiodecontamination. PMID:21829318
Alberts, Johanna F; van Zyl, Willem H; Gelderblom, Wentzel C A
2016-01-01
Infection by the fumonisin-producing Fusarium spp. and subsequent fumonisin contamination of maize adversely affect international trade and economy with deleterious effects on human and animal health. In developed countries high standards of the major food suppliers and retailers are upheld and regulatory controls deter the importation and local marketing of fumonisin-contaminated food products. In developing countries regulatory measures are either lacking or poorly enforced, due to food insecurity, resulting in an increased mycotoxin exposure. The lack and poor accessibility of effective and environmentally safe control methods have led to an increased interest in practical and biological alternatives to reduce fumonisin intake. These include the application of natural resources, including plants, microbial cultures, genetic material thereof, or clay minerals pre- and post-harvest. Pre-harvest approaches include breeding for resistant maize cultivars, introduction of biocontrol microorganisms, application of phenolic plant extracts, and expression of antifungal proteins and fumonisin degrading enzymes in transgenic maize cultivars. Post-harvest approaches include the removal of fumonisins by natural clay adsorbents and enzymatic degradation of fumonisins through decarboxylation and deamination by recombinant carboxylesterase and aminotransferase enzymes. Although, the knowledge base on biological control methods has expanded, only a limited number of authorized decontamination products and methods are commercially available. As many studies detailed the use of natural compounds in vitro, concepts in reducing fumonisin contamination should be developed further for application in planta and in the field pre-harvest, post-harvest, and during storage and food-processing. In developed countries an integrated approach, involving good agricultural management practices, hazard analysis and critical control point (HACCP) production, and storage management, together with selected biologically based treatments, mild chemical and physical treatments could reduce fumonisin contamination effectively. In rural subsistence farming communities, simple, practical, and culturally acceptable hand-sorting, maize kernel washing, and dehulling intervention methods proved to be effective as a last line of defense for reducing fumonisin exposure. Biologically based methods for control of fumonisin-producing Fusarium spp. and decontamination of the fumonisins could have potential commercial application, while simple and practical intervention strategies could also impact positively on food safety and security, especially in rural populations reliant on maize as a dietary staple.
Autonomous bio-chemical decontaminator (ABCD) against weapons of mass destruction
NASA Astrophysics Data System (ADS)
Hyacinthe, Berg P.
2006-05-01
The proliferation of weapons of mass destruction (WMD) and the use of such elements pose an eminent asymmetric threat with disastrous consequences to the national security of any nation. In particular, the use of biochemical warfare agents against civilians and unprotected troops in international conflicts or by terrorists against civilians is considered as a very peculiar threat. Accordingly, taking a quarantine-before-inhalation approach to biochemical warfare, the author introduces the notion of autonomous biochemical decontamination against WMD. In the unfortunate event of a biochemical attack, the apparatus proposed herein is intended to automatically detect, identify, and more importantly neutralize a biochemical threat. Along with warnings concerning a cyber-WMD nexus, various sections cover discussions on human senses and computer sensors, corroborating evidence related to detection and neutralization of chemical toxins, and cyber-assisted olfaction in stand alone, peer-to-peer, and network settings. In essence, the apparatus can be used in aviation and mass transit security to initiate mass decontamination by dispersing a decontaminant aerosol or to protect the public water supply against a potential bioterrorist attack. Future effort may involve a system-on-chip (SoC) embodiment of this apparatus that allows a safer environment for the emerging phenomenon of cyber-assisted olfaction and morph cell phones into ubiquitous sensors/decontaminators. Although this paper covers mechanisms and protocols to avail a neutralizing substance, further research will need to explore the substance's various pharmacological profiles and potential side effects.
Love, Adam H; Bailey, Christopher G; Hanna, M Leslie; Hok, Saphon; Vu, Alex K; Reutter, Dennis J; Raber, Ellen
2011-11-30
Bench-scale testing was used to evaluate the efficacy of four decontamination formulations on typical indoor surfaces following exposure to the liquid chemical warfare agents sarin (GB), soman (GD), sulfur mustard (HD), and VX. Residual surface contamination on coupons was periodically measured for up to 24h after applying one of four selected decontamination technologies [0.5% bleach solution with trisodium phosphate, Allen Vanguard Surface Decontamination Foam (SDF™), U.S. military Decon Green™, and Modec Inc. and EnviroFoam Technologies Sandia Decontamination Foam (DF-200)]. All decontamination technologies tested, except for the bleach solution, performed well on nonporous and nonpermeable glass and stainless-steel surfaces. However, chemical agent residual contamination typically remained on porous and permeable surfaces, especially for the more persistent agents, HD and VX. Solvent-based Decon Green™ performed better than aqueous-based bleach or foams on polymeric surfaces, possibly because the solvent is able to penetrate the polymer matrix. Bleach and foams out-performed Decon Green for penetrating the highly polar concrete surface. Results suggest that the different characteristics needed for an ideal and universal decontamination technology may be incompatible in a single formulation and a strategy for decontaminating a complex facility will require a range of technologies. Copyright © 2011 Elsevier B.V. All rights reserved.
Decontamination and management of human remains following incidents of hazardous chemical release.
Hauschild, Veronique D; Watson, Annetta; Bock, Robert
2012-01-01
To provide specific guidance and resources for systematic and orderly decontamination of human remains resulting from a chemical terrorist attack or accidental chemical release. A detailed review and health-based decision criteria protocol is summarized. Protocol basis and logic are derived from analyses of compound-specific toxicological data and chemical/physical characteristics. Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present, such as sites of transportation accidents, terrorist operations, or medical examiner processing points. Guidance is developed from data-characterizing controlled experiments with laboratory animals, fabrics, and materiel. Logic and specific procedures for decontamination and management of remains, protection of mortuary affairs personnel, and decision criteria to determine when remains are sufficiently decontaminated are presented. Established procedures as well as existing materiel and available equipment for decontamination and verification provide reasonable means to mitigate chemical hazards from chemically exposed remains. Unique scenarios such as those involving supralethal concentrations of certain liquid chemical warfare agents may prove difficult to decontaminate but can be resolved in a timely manner by application of the characterized systematic approaches. Decision criteria and protocols to "clear" decontaminated remains for transport and processing are also provided. Once appropriate decontamination and verification have been accomplished, normal procedures for management of remains and release can be followed.
Pipolo, Marco; Martins, Rui C; Quinta-Ferreira, Rosa M; Costa, Raquel
2017-03-01
The discharge of poorly decontaminated winery wastewater remains a serious environmental problem in many regions, and the industry is welcoming improved treatment methods. Here, an innovative decontamination approach integrating Fenton's process with biofiltration by Asian clams is proposed. The potential of this approach was assessed at the pilot scale using real effluent and by taking an actual industrial treatment system as a benchmark. Fenton peroxidation was observed to remove 84% of the effluent's chemical oxygen demand (COD), reducing it to 205 mg L. Subsequent biofiltration decreased the effluent's COD to approximately zero, well below the legal discharge limit of 150 mg L, in just 3 d. The reduction of the effluent's organic load through Fenton's process did not decrease its toxicity toward , but the effluent was much less harmful after biofiltration. The performance of the treatment proposed exceeded that of the integrated Fenton's process-sequencing batch reactor design implemented in the winery practice, where a residence time of around 10 d in the biological step typically results in 80 to 90% of COD removal. The method proposed is effective and compatible with typical winery budgets and potentially contributes to the management of a nuisance species. Copyright © by the American Society of Agronomy, Crop Science Society of America, and Soil Science Society of America, Inc.
Decontamination of food packaging using electron beam—status and prospects
NASA Astrophysics Data System (ADS)
Mittendorfer, J.; Bierbaumer, H. P.; Gratzl, F.; Kellauer, E.
2002-03-01
In this paper the status of food packaging disinfection decontamination using electron beam at Mediscan GmbH is presented. The first section of the paper describes the activities at the service center, where food packaging materials, e.g. yoghurt cups are decontaminated in their final shipment containers. As important step in the hazard analysis and critical control point of food processing, microbiological uncontaminated food packaging material is of public interest and attracts a lot of attention from packaging material producers and food processors. The dose ranges for different sterility assurance levels are discussed and results from microbiological test are presented. Studies at Mediscan have demonstrated, that an electron beam treatment at a dose of 5-7 kGy is most effective against yeast and mold, which are mainly responsible for spoilage and short shelf-life of a variety of products. The second section is devoted to the field of inline decontamination of food packaging and sterilization of pharmaceutical packaging material and the research currently conducted at Mediscan. The requirements for industrial inline electron beam systems are summarized and design concepts discussed in terms of beam energy, beam current, irradiation topology, product handling and shielding.
Pini-Prato, Giovanpaolo; Magnani, Cristina; Rotundo, Roberto
2016-01-01
The aim of this preliminary study was to show the treatment effect of the biofilm decontamination approach on acute periodontal abscesses. Clinical cases showing acute periodontitis were treated using an oral tissue decontaminant material that contains a concentrated aqueous mixture of hydroxybenzenesulfonic and hydroxymethoxybenzene acids and sulfuric acid. The material was positioned into the pocket on the root surface and left in the site for 30 seconds. No instrumentation was performed before the treatment. No systemic or local antibiotics were used in any of the cases. A questionnaire was used for each patient to record the pain/discomfort felt when the material was administered. All of the treated cases healed well and very rapidly. The infections were quickly resolved without complications, and the pockets associated with marginal tissue recession were also reduced. The momentary pain upon introduction of the material was generally well tolerated in the nonsurgically treated cases, and it completely disappeared after a few seconds. The biofilm decontamination approach seems to be a very promising technique for the treatment of acute periodontal abscess. The local application of this material avoids the use of systemic or local antibiotics.
Conversion of transuranic waste to low level waste by decontamination: a site specific update
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allen, R.P.; Hazelton, R.F.
1985-09-01
As a followup to an FY-1984 cost/benefit study, a program was conducted in FY-1985 to transfer to the relevant DOE sites the information and technology for the direct conversion of transuranic (TRU) waste to low-level waste (LLW) by decontamination. As part of this work, the economic evaluation of the various TRUW volume reduction and conversion options was updated and expanded to include site-specific factors. The results show, for the assumptions used, that size reduction, size reduction followed by decontamination, or in situ decontamination are cost effective compared with the no-processing option. The technology transfer activities included site presentations and discussionsmore » with operations and waste management personnel to identify application opportunities and site-specific considerations and constraints that could affect the implementation of TRU waste conversion principles. These discussions disclosed definite potential for the beneficial application of these principles at most of the sites, but also confirmed the existence of site-specific factors ranging from space limitations to LLW disposal restrictions that could preclude particular applications or diminish expected benefits. 8 refs., 2 figs., 4 tabs.« less
Periimplantitis Treatment: Long-Term Comparison of Laser Decontamination and Implantoplasty Surgery.
Pommer, Bernhard; Haas, Robert; Mailath-Pokorny, Georg; Fürhauser, Rudolf; Watzek, Georg; Busenlechner, Dieter; Müller-Kern, Michael; Kloodt, Claudia
2016-10-01
Periimplantitis is the most frequent cause of late implant failure; however, little is known about the long-term success of periimplantitis treatment and the effectiveness of various therapeutic interventions. A total of 142 patients were referred to the Academy for Oral Implantology in Vienna for the treatment of recurrent periimplantitis around single-tooth implants. Of them, 72 patients (51%) were treated by laser decontamination, 47 patients (33%) by implantoplasty surgery, and 23 patients (16%) by a combination of both approaches. Overall success of periimplantitis therapy was 89% after 9 years of follow-up, and it did not differ significantly between female and male patients (P = 0.426). The number of implant failures that could not be prevented by periimplantitis treatment was 6 after laser decontamination (8%), 6 after implantoplasty surgery (13%), and 4 after a combination of both therapies (17%). Implant loss occurred after 4.9 ± 1.9 years of therapy, on average. No significant difference between the 3 treatment groups could be observed (P = 0.393). The present results suggest that success rates of periimplantitis therapy with either laser decontamination or surgical implantoplasty are high. These success rates do not appear to be associated with patient gender or treatment strategy.
Fighting Ebola with novel spore decontamination technologies for the military.
Doona, Christopher J; Feeherry, Florence E; Kustin, Kenneth; Olinger, Gene G; Setlow, Peter; Malkin, Alexander J; Leighton, Terrance
2015-01-01
Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC's novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established non-thermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers, using an array of Bacillus subtilis mutants to probe mechanisms of spore germination and inactivation. We employ techniques of high-resolution atomic force microscopy and phase contrast microscopy to examine the effects of γ-irradiation on bacterial spores of Bacillus anthracis, Bacillus thuringiensis, and Bacillus atrophaeus spp. and of ClO2 on B. subtilis spores, and present in detail assays using spore bio-indicators to ensure sterility when decontaminating with ClO2.
Berntssen, M H G; Olsvik, P A; Torstensen, B E; Julshamn, K; Midtun, T; Goksøyr, A; Johansen, J; Sigholt, T; Joerum, N; Jakobsen, J-V; Lundebye, A-K; Lock, E-J
2010-09-01
Oily fish are an important source of health promoting nutrients such as the very long chain marine omega-3 (VLC-n3) fatty acids and simultaneously a source of potentially hazardous contaminants. Fish oils that are used in fish feed are the main source for both contaminants and VLC-n3. Decontamination techniques have recently been developed to effectively remove persistent organic contaminants from fish oils. The aim of the present study was to assess the level of potentially hazardous contaminants and the health beneficial fatty acids in Atlantic salmon reared on novel decontaminated feeds. Atlantic salmon were fed for 18 months (an entire seawater production cycle) on diets based on decontaminated or non-treated (control) fish oils until market size (approximately 5 kg). The level of known notorious persistent organic pollutants (POPs, i.e. dioxins, dioxin-like polychlorinated biphenyls (DL-PCBs), non dioxin-like PCBs, poly brominated diphenyl ethers (PBDE), and organochlorine pesticides), as well as fatty acid composition were analysed in fish oils, the two diets, and Atlantic salmon fillet. The oil decontamination process was a two-step procedure using active carbon and short path distillation. The fillet levels of POPs in market size fish were reduced by 68-85% while the concentration of very long chain omega-3 fatty acids was reduced by 4-7%. No differences in biomarkers of dioxin-like component exposures, such as hepatic gene expression of CYP1A or AhR2B, CYP1A protein expression and 7-ethoxyresorufin O-deethylase (EROD) activity, were observed between salmon raised on normal or decontaminated feeds, thus indicating that the difference in POPs levels were of no biological significance to the fish. Atlantic salmon reared on decontaminated feeds had sum polychlorinated dibenzodioxins/furans (PCDD/Fs) and DL-PCB concentrations that were comparable with terrestrial food products such as beef, while the level of marine omega-3 fatty acids remained as high as for commercially farmed Atlantic salmon. (c) 2010 Elsevier Ltd. All rights reserved.
Fighting Ebola with novel spore decontamination technologies for the military
Doona, Christopher J.; Feeherry, Florence E.; Kustin, Kenneth; Olinger, Gene G.; Setlow, Peter; Malkin, Alexander J.; Leighton, Terrance
2015-01-01
Recently, global public health organizations such as Doctors without Borders (MSF), the World Health Organization (WHO), Public Health Canada, National Institutes of Health (NIH), and the U.S. government developed and deployed Field Decontamination Kits (FDKs), a novel, lightweight, compact, reusable decontamination technology to sterilize Ebola-contaminated medical devices at remote clinical sites lacking infra-structure in crisis-stricken regions of West Africa (medical waste materials are placed in bags and burned). The basis for effectuating sterilization with FDKs is chlorine dioxide (ClO2) produced from a patented invention developed by researchers at the US Army Natick Soldier RD&E Center (NSRDEC) and commercialized as a dry mixed-chemical for bacterial spore decontamination. In fact, the NSRDEC research scientists developed an ensemble of ClO2 technologies designed for different applications in decontaminating fresh produce; food contact and handling surfaces; personal protective equipment; textiles used in clothing, uniforms, tents, and shelters; graywater recycling; airplanes; surgical instruments; and hard surfaces in latrines, laundries, and deployable medical facilities. These examples demonstrate the far-reaching impact, adaptability, and versatility of these innovative technologies. We present herein the unique attributes of NSRDEC’s novel decontamination technologies and a Case Study of the development of FDKs that were deployed in West Africa by international public health organizations to sterilize Ebola-contaminated medical equipment. FDKs use bacterial spores as indicators of sterility. We review the properties and structures of spores and the mechanisms of bacterial spore inactivation by ClO2. We also review mechanisms of bacterial spore inactivation by novel, emerging, and established non-thermal technologies for food preservation, such as high pressure processing, irradiation, cold plasma, and chemical sanitizers, using an array of Bacillus subtilis mutants to probe mechanisms of spore germination and inactivation. We employ techniques of high-resolution atomic force microscopy and phase contrast microscopy to examine the effects of γ-irradiation on bacterial spores of Bacillus anthracis, Bacillus thuringiensis, and Bacillus atrophaeus spp. and of ClO2 on B. subtilis spores, and present in detail assays using spore bio-indicators to ensure sterility when decontaminating with ClO2. PMID:26322021
Pierrard, Marie-Aline; Kestemont, Patrick; Phuong, Nguyen Thanh; Tran, Minh Phu; Delaive, Edouard; Thezenas, Marie-Laëtitia; Dieu, Marc; Raes, Martine; Silvestre, Frédéric
2012-04-18
Proteomics technology are increasingly used in ecotoxicological studies to characterize and monitor biomarkers of exposure. The present study aims at identifying long term effects of malachite green (MG) exposure on the proteome of peripheral blood mononuclear cells (PBMC) from the Asian catfish, Pangasianodon hypophthalmus. A common (0.1 ppm) concentration for therapeutic treatment was applied twice with a 72 h interval. PBMC were collected directly at the end of the second bath of MG (T1) and after 1 month of decontamination (T2). Analytical 2D-DIGE gels were run and a total of 2551±364 spots were matched. Among them, MG induced significant changes in abundance of 116 spots with no recovery after one month of decontamination. Using LC-MS/MS and considering single identification per spot, we could identify 25 different proteins. Additionally, MG residues were measured in muscle and in blood indicating that leuco-MG has almost totally disappeared after one month of decontamination. This work highlights long term effects of MG treatment on the PBMC proteome from fish intended for human consumption. Copyright © 2012 Elsevier B.V. All rights reserved.
Protocol for Detection of Bacillus anthracis in Environmental Samples
This pProtocol Method describes proceduresintended for the analyses of swabs, wipes, Sponge-Sticks, vacuum socks and filters, air filters, drinking water, and decontamination waste water for Bacillus anthracis spores.
Nuclear Research Reactor IEA-R1 - A Study of the Preparing for Decommissioning
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lopes, Valdir Maciel; Filho, Tufic Madi; Ricci, Walter
2015-07-01
The Institute of Energy and Nuclear Research (IPEN), Sao Paulo, according to the assignments given by the National Commission of Nuclear Energy (CNEN), enabled the development of this study, especially operational reports about refurbishing carried out on 2013, involving the production of radioisotopes and research in the areas of Radiochemistry and Nuclear Physics. These reports are made in accordance with established standard procedures to meet the requirements of CNEN (National Nuclear Energy Commission, the regulator the nuclear area activities in Brazil) and IAEA (International Atomic Energy Agency). This study presents an assessment of the procedures and methods of treatments formore » decontamination of the refrigeration primary circuit and changes parts, equipment and tubes of the of the IEA-R1 nuclear research reactor, pool type, power between 3,5 and 4,5 MW. In order to have a sequence in the work, the well-known contaminant radioisotopes were evaluated firstly, using Geiger- Muller equipment. In the second phase, the decontamination was done manually together with the ultrasound cleaning and washing equipment. From the several water solutions of citric acid assessment, the concentration with better confidence was obtained; in order to achieve the best results for decontamination. This study intends to define the best process for decontamination with low taxes of waste and without expensive costs. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Taylor-Pashow, Kathryn M.; Nash, Charles A.; Crawford, Charles L.
2014-01-21
The Hanford Waste Treatment and Immobilization Plant (WTP) Low Activity Waste (LAW) vitrification facility will generate an aqueous condensate recycle stream (LAW Off-Gas Condensate) from the off-gas system. The baseline plan for disposition of this stream is to send it to the WTP Pretreatment Facility, where it will be blended with LAW, concentrated by evaporation and recycled to the LAW vitrification facility again. Alternate disposition of this stream would eliminate recycling of problematic components, and would enable de-coupled operation of the LAW melter and the Pretreatment Facilities. Eliminating this stream from recycling within WTP would also decrease the LAW vitrificationmore » mission duration and quantity of glass waste. This LAW Off-Gas Condensate stream contains components that are volatile at melter temperatures and are problematic for the glass waste form. Because this stream recycles within WTP, these components accumulate in the Condensate stream, exacerbating their impact on the number of LAW glass containers that must be produced. Approximately 32% of the sodium in Supplemental LAW comes from glass formers used to make the extra glass to dilute the halides to acceptable concentrations in the LAW glass, and diverting the stream reduces the halides in the recycled Condensate and is a key outcome of this work. Additionally, under possible scenarios where the LAW vitrification facility commences operation prior to the WTP Pretreatment facility, identifying a disposition path becomes vitally important. This task seeks to examine the potential treatment of this stream to remove radionuclides and subsequently disposition the decontaminated stream elsewhere, such as the Effluent Treatment Facility (ETF), for example. The treatment process envisioned is very similar to that used for the Actinide Removal Process (ARP) that has been operating for years at the Savannah River Site (SRS), and focuses on using mature radionuclide removal technologies that are also compatible with longterm tank storage and immobilization methods. For this new application, testing is needed to demonstrate acceptable treatment sorbents and precipitating agents and measure decontamination factors for additional radionuclides in this unique waste stream. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet and will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. One of the radionuclides that is volatile and expected to be in high concentration in this LAW Off-Gas Condensate stream is Technetium-99 ( 99Tc). Technetium will not be removed from the aqueous waste in the Hanford WTP, and will primarily end up immobilized in the LAW glass by repeated recycle of the off-gas condensate into the LAW melter. Other radionuclides that are also expected to be in appreciable concentration in the LAW Off-Gas Condensate are 129I, 90Sr, 137Cs, and {sup 241}Am. This report discusses results of preliminary radionuclide decontamination testing of the simulant. Testing examined use of Monosodium Titanate (MST) to remove 90Sr and actinides, inorganic reducing agents for 99Tc, and zeolites for 137Cs. Test results indicate that excellent removal of 99Tc was achieved using Sn(II)Cl 2 as a reductant, coupled with sorption onto hydroxyapatite, even in the presence of air and at room temperature. This process was very effective at neutral pH, with a Decontamination Factor (DF) >577 in two hours. It was less effective at alkaline pH. Conversely, removal of the cesium was more effective at alkaline pH, with a DF of 17.9. As anticipated, ammonium ion probably interfered with the Ionsiv®a IE-95 zeolite uptake of 137Cs. Although this DF of 137Cs was moderate, additional testing is expected to identify more effective conditions. Similarly, Monosodium Titanate (MST) was more effective at alkaline pH at removing Sr, Pu, and U, with a DF of 319, 11.6, and 10.5, respectively, within 24 hours. Actually, the Ionsiv® IE-95, which was targeting removal of Cs, was also moderately effective for Sr, and highly effective for Pu and U at alkaline pH. The only deleterious effect observed was that the chromium co-precipitates with the {sup 99}Tc during the SnCl 2 reduction. This effect was anticipated, and would have to be considered when managing disposition paths of this stream. Results of this separation testing indicate that sorption/precipitation was a viable concept and has the potential to decontaminate the stream. All radionuclides were at least partially removed by one or more of the materials tested. Based on the results, a possible treatment scenario could involve the use of a reductive precipitation agent (SnCl 2) and sorbent at neutral pH to remove the Tc, followed by pH adjustment and the addition of zeolite (Ionsiv® IE-95) to remove the Cs, Sr, and actinides. Addition of MST to remove Sr and actinides may not be needed. Since this was an initial phase of testing, additional tasks to improve separation methods were expected to be identified. Primarily, further testing is needed to identify the conditions for the decontamination process. Once these conditions are established, follow-on tasks likely include evaluation and testing of applicable solid-liquid separation technologies, slurry rheology measurements, composition variability testing and evaluations, corrosion and erosion testing, slurry storage and immobilization investigations, and decontaminated LAW Off-Gas Condensate evaporation and solidification.« less
Applications of polymeric smart materials to environmental problems.
Gray, H N; Bergbreiter, D E
1997-01-01
New methods for the reduction and remediation of hazardous wastes like carcinogenic organic solvents, toxic materials, and nuclear contamination are vital to environmental health. Procedures for effective waste reduction, detection, and removal are important components of any such methods. Toward this end, polymeric smart materials are finding useful applications. Polymer-bound smart catalysts are useful in waste minimization, catalyst recovery, and catalyst reuse. Polymeric smart coatings have been developed that are capable of both detecting and removing hazardous nuclear contaminants. Such applications of smart materials involving catalysis chemistry, sensor chemistry, and chemistry relevant to decontamination methodology are especially applicable to environmental problems. PMID:9114277
Current and Future Technologies for Microbiological Decontamination of Cereal Grains.
Los, Agata; Ziuzina, Dana; Bourke, Paula
2018-06-01
Cereal grains are the most important staple foods for mankind worldwide. The constantly increasing annual production and yield is matched by demand for cereals, which is expected to increase drastically along with the global population growth. A critical food safety and quality issue is to minimize the microbiological contamination of grains as it affects cereals both quantitatively and qualitatively. Microorganisms present in cereals can affect the safety, quality, and functional properties of grains. Some molds have the potential to produce harmful mycotoxins and pose a serious health risk for consumers. Therefore, it is essential to reduce cereal grain contamination to the minimum to ensure safety both for human and animal consumption. Current production of cereals relies heavily on pesticides input, however, numerous harmful effects on human health and on the environment highlight the need for more sustainable pest management and agricultural methods. This review evaluates microbiological risks, as well as currently used and potential technologies for microbiological decontamination of cereal grains. © 2018 Institute of Food Technologists®.
DECHLORINATION OF TRICHLOROETHYLENE USING ELECTROCHEMICAL METHODS
Electrochemical degradation (ECD) is used to decontaminate organic and inorganic contaminants through oxidative or reductive processes. The ECD of Trichloroethylene (TCE) dechlorinates TCE through electric reduction. TCE dechlorination presented in the literature utilized electro...