Sample records for effective dose range

  1. Dose rate mapping of VMAT treatments

    NASA Astrophysics Data System (ADS)

    Podesta, Mark; Antoniu Popescu, I.; Verhaegen, Frank

    2016-06-01

    Human tissues exhibit a varying response to radiation dose depending on the dose rate and fractionation scheme used. Dose rate effects have been reported for different radiations, and tissue types. The literature indicates that there is not a significant difference in response for low-LET radiation when using dose rates between 1 Gy min-1 and 12 Gy min-1 but lower dose rates have an observable sparing effect on tissues and a differential effect between tissues. In intensity-modulated radiotherapy such as volumetric modulated arc therapy (VMAT) the dose can be delivered with a wide range of dose rates. In this work we developed a method based on time-resolved Monte Carlo simulations to quantify the dose rate frequency distribution for clinical VMAT treatments for three cancer sites, head and neck, lung, and pelvis within both planning target volumes (PTV) and normal tissues. The results show a wide range of dose rates are used to deliver dose in VMAT and up to 75% of the PTV can have its dose delivered with dose rates  <1 Gy min-1. Pelvic plans on average have a lower mean dose rate within the PTV than lung or head and neck plans but a comparable mean dose rate within the organs at risk. Two VMAT plans that fulfil the same dose objectives and constraints may be delivered with different dose rate distributions, particularly when comparing single arcs to multiple arc plans. It is concluded that for dynamic plans, the dose rate range used varies to a larger degree than previously assumed. The effect of the dose rate range in VMAT on clinical outcome is unknown.

  2. Effective radiation dose of ProMax 3D cone-beam computerized tomography scanner with different dental protocols.

    PubMed

    Qu, Xing-min; Li, Gang; Ludlow, John B; Zhang, Zu-yan; Ma, Xu-chen

    2010-12-01

    The aim of this study was to compare effective doses resulting from different scan protocols for cone-beam computerized tomography (CBCT) using International Commission on Radiological Protection (ICRP) 1990 and 2007 calculations of dose. Average tissue-absorbed dose, equivalent dose, and effective dose for a ProMax 3D CBCT with different dental protocols were calculated using thermoluminescent dosimeter chips in a human equivalent phantom. Effective doses were derived using ICRP 1990 and the superseding 2007 recommendations. Effective doses (ICRP 2007) for default patient sizes from small to large ranged from 102 to 298 μSv. The coefficient of determination (R(2)) between tube current and effective dose (ICRP 2007) was 0.90. When scanning with lower resolution settings, the effective doses were reduced significantly (P < .05). ProMax 3D can provide a wide range of radiation dose levels. Reduction in radiation dose can be achieved when using lower settings of exposure parameters. Copyright © 2010 Mosby, Inc. All rights reserved.

  3. SU-E-T-248: An Extended Generalized Equivalent Uniform Dose Accounting for Dose-Range Dependency of Radio-Biological Parameters.

    PubMed

    Troeller, A; Soehn, M; Yan, D

    2012-06-01

    Introducing an extended, phenomenological, generalized equivalent uniform dose (eEUD) that incorporates multiple volume-effect parameters for different dose-ranges. The generalized EUD (gEUD) was introduced as an estimate of the EUD that incorporates a single, tissue-specific parameter - the volume-effect-parameter (VEP) 'a'. As a purely phenomenological concept, its radio-biological equivalency to a given inhomogeneous dose distribution is not a priori clear and mechanistic models based on radio-biological parameters are assumed to better resemble the underlying biology. However, for normal organs mechanistic models are hard to derive, since the structural organization of the tissue plays a significant role. Consequently, phenomenological approaches might be especially useful in order to describe dose-response for normal tissues. However, the single parameter used to estimate the gEUD may not suffice in accurately representing more complex biological effects that have been discussed in the literature. For instance, radio-biological parameters and hence the effects of fractionation are known to be dose-range dependent. Therefore, we propose an extended phenomenological eEUD formula that incorporates multiple VEPs accounting for dose-range dependency. The eEUD introduced is a piecewise polynomial expansion of the gEUD formula. In general, it allows for an arbitrary number of VEPs, each valid for a certain dose-range. We proved that the formula fulfills required mathematical and physical criteria such as invertibility of the underlying dose-effect and continuity in dose. Furthermore, it contains the gEUD as a special case, if all VEPs are equal to 'a' from the gEUD model. The eEUD is a concept that expands the gEUD such that it can theoretically represent dose-range dependent effects. Its practicality, however, remains to be shown. As a next step, this will be done by estimating the eEUD from patient data using maximum-likelihood based NTCP modelling in the same way it is commonly done for the gEUD. © 2012 American Association of Physicists in Medicine.

  4. Estimation of organ and effective doses from newborn radiography of the chest and abdomen.

    PubMed

    Ma, Hillgan; Elbakri, Idris A; Reed, Martin

    2013-09-01

    Neonatal intensive care patients undergo frequent chest and abdomen radiographic imaging. In this study, the organ doses and the effective dose resulting from combined chest-abdomen radiography of the newborn child are determined. These values are calculated using the Monte Carlo simulation software PCXCM 2.0 and compared with direct dose measurements obtained from thermoluminescent detectors (TLDs) in a physical phantom. The effective dose obtained from PCXMC is 21.2 ± 0.7 μSv and that obtained from TLD measurements is 22.0 ± 0.5 μSv. While the two methods are in close agreement with regard to the effective dose, there is a wide range of variation in organ doses, ranging from 85 % difference for the testes to 1.4 % for the lungs. Large organ dose variations are attributed to organs at the edge of the field of view, or organs with large experimental error or simulation uncertainty. This study suggests that PCXMC can be used to estimate organ and effective doses for newborn patients.

  5. Hormones and Endocrine-Disrupting Chemicals: Low-Dose Effects and Nonmonotonic Dose Responses

    PubMed Central

    Colborn, Theo; Hayes, Tyrone B.; Heindel, Jerrold J.; Jacobs, David R.; Lee, Duk-Hee; Shioda, Toshi; Soto, Ana M.; vom Saal, Frederick S.; Welshons, Wade V.; Zoeller, R. Thomas

    2012-01-01

    For decades, studies of endocrine-disrupting chemicals (EDCs) have challenged traditional concepts in toxicology, in particular the dogma of “the dose makes the poison,” because EDCs can have effects at low doses that are not predicted by effects at higher doses. Here, we review two major concepts in EDC studies: low dose and nonmonotonicity. Low-dose effects were defined by the National Toxicology Program as those that occur in the range of human exposures or effects observed at doses below those used for traditional toxicological studies. We review the mechanistic data for low-dose effects and use a weight-of-evidence approach to analyze five examples from the EDC literature. Additionally, we explore nonmonotonic dose-response curves, defined as a nonlinear relationship between dose and effect where the slope of the curve changes sign somewhere within the range of doses examined. We provide a detailed discussion of the mechanisms responsible for generating these phenomena, plus hundreds of examples from the cell culture, animal, and epidemiology literature. We illustrate that nonmonotonic responses and low-dose effects are remarkably common in studies of natural hormones and EDCs. Whether low doses of EDCs influence certain human disorders is no longer conjecture, because epidemiological studies show that environmental exposures to EDCs are associated with human diseases and disabilities. We conclude that when nonmonotonic dose-response curves occur, the effects of low doses cannot be predicted by the effects observed at high doses. Thus, fundamental changes in chemical testing and safety determination are needed to protect human health. PMID:22419778

  6. Effective radiation dose and eye lens dose in dental cone beam CT: effect of field of view and angle of rotation.

    PubMed

    Pauwels, R; Zhang, G; Theodorakou, C; Walker, A; Bosmans, H; Jacobs, R; Bogaerts, R; Horner, K

    2014-10-01

    To quantify the effect of field of view (FOV) and angle of rotation on radiation dose in dental cone beam CT (CBCT) and to define a preliminary volume-dose model. Organ and effective doses were estimated using 148 thermoluminescent dosemeters placed in an anthropomorphic phantom. Dose measurements were undertaken on a 3D Accuitomo 170 dental CBCT unit (J. Morita, Kyoto, Japan) using six FOVs as well as full-rotation (360°) and half-rotation (180°) protocols. For the 360° rotation protocols, effective dose ranged between 54 µSv (4 × 4 cm, upper canine) and 303 µSv (17 × 12 cm, maxillofacial). An empirical relationship between FOV dimension and effective dose was derived. The use of a 180° rotation resulted in an average dose reduction of 45% compared with a 360° rotation. Eye lens doses ranged between 95 and 6861 µGy. Significant dose reduction can be achieved by reducing the FOV size, particularly the FOV height, of CBCT examinations to the actual region of interest. In some cases, a 180° rotation can be preferred, as it has the added value of reducing the scan time. Eye lens doses should be reduced by decreasing the height of the FOV rather than using inferior FOV positioning, as the latter would increase the effective dose considerably. The effect of the FOV and rotation angle on the effective dose in dental CBCT was quantified. The dominant effect of FOV height was demonstrated. A preliminary model has been proposed, which could be used to predict effective dose as a function of FOV size and position.

  7. High-pitch computed tomography coronary angiography-a new dose-saving algorithm: estimation of radiation exposure.

    PubMed

    Ketelsen, Dominik; Buchgeister, Markus; Korn, Andreas; Fenchel, Michael; Schmidt, Bernhard; Flohr, Thomas G; Thomas, Christoph; Schabel, Christoph; Tsiflikas, Ilias; Syha, Roland; Claussen, Claus D; Heuschmid, Martin

    2012-01-01

    Purpose. To estimate effective dose and organ equivalent doses of prospective ECG-triggered high-pitch CTCA. Materials and Methods. For dose measurements, an Alderson-Rando phantom equipped with thermoluminescent dosimeters was used. The effective dose was calculated according to ICRP 103. Exposure was performed on a second-generation dual-source scanner (SOMATOM Definition Flash, Siemens Medical Solutions, Germany). The following scan parameters were used: 320 mAs per rotation, 100 and 120 kV, pitch 3.4 for prospectively ECG-triggered high-pitch CTCA, scan range of 13.5 cm, collimation 64 × 2 × 0.6 mm with z-flying focal spot, gantry rotation time 280 ms, and simulated heart rate of 60 beats per minute. Results. Depending on the applied tube potential, the effective whole-body dose of the cardiac scan ranged from 1.1 mSv to 1.6 mSv and from 1.2 to 1.8 mSv for males and females, respectively. The radiosensitive breast tissue in the range of the primary beam caused an increased female-specific effective dose of 8.6%±0.3% compared to males. Decreasing the tube potential, a significant reduction of the effective dose of 35.8% and 36.0% can be achieved for males and females, respectively (P < 0.001). Conclusion. The radiologist and the CT technician should be aware of this new dose-saving strategy to keep the radiation exposure as low as reasonablly achievable.

  8. Psychopharmacology of theobromine in healthy volunteers.

    PubMed

    Baggott, Matthew J; Childs, Emma; Hart, Amy B; de Bruin, Eveline; Palmer, Abraham A; Wilkinson, Joy E; de Wit, Harriet

    2013-07-01

    Theobromine, a methylxanthine related to caffeine and present in high levels in cocoa, may contribute to the appeal of chocolate. However, current evidence for this is limited. We conducted a within-subjects placebo-controlled study of a wide range of oral theobromine doses (250, 500, and 1,000 mg) using an active control dose of caffeine (200 mg) in 80 healthy participants. Caffeine had the expected effects on mood including feelings of alertness and cardiovascular parameters. Theobromine responses differed according to dose; it showed limited subjective effects at 250 mg and negative mood effects at higher doses. It also dose-dependently increased heart rate. In secondary analyses, we also examined individual differences in the drug's effects in relation to genes related to their target receptors, but few associations were detected. This study represents the highest dose of theobromine studied in humans. We conclude that theobromine at normal intake ranges may contribute to the positive effects of chocolate, but at higher intakes, effects become negative.

  9. Psychopharmacology of theobromine in healthy volunteers

    PubMed Central

    Baggott, Matthew J.; Childs, Emma; Hart, Amy B.; de Bruin, Eveline; Palmer, Abraham A.; Wilkinson, Joy E.; de Wit, Harriet

    2013-01-01

    Background Theobromine, a methylxanthine related to caffeine and present in high levels in cocoa, may contribute to the appeal of chocolate. However, currently evidence for this is limited. Objectives We conducted a within-subjects placebo-controlled study of a wide range of oral theobromine doses (250, 500, and 1000 mg) using an active control dose of caffeine (200 mg) in 80 healthy participants. Results Caffeine had the expected effects on mood including feelings of alertness, and cardiovascular parameters. Theobromine responses differed according to dose: it showed limited subjective effects at 250 mg and negative mood effects at higher doses. It also dose-dependently increased heart rate. In secondary analyses we also examined individual differences in the drugs' effects in relation to genes related to their target receptors, but few associations were detected. Conclusions This study represents the highest dose of theobromine studied in humans. We conclude that theobromine at normal intake ranges may contribute to the positive effects of chocolate, but at higher intakes effects become negative. PMID:23420115

  10. Dose Response Data for Hormonally Active Chemicals: Estrogens, Antiandrogens and Androgens

    EPA Science Inventory

    The shape of the dose response curve in the low dose region has been debated since the late 1940s. The debate originally focused on linear no threshold (LNT) vs threshold responses in the low dose range for cancer and noncancer related effects. For noncancer effects the defaul...

  11. [Acute toxicity of bemithyl and bromithyl].

    PubMed

    Bugaeva, L I; Spasov, A A; Verovskiĭ, V E; Iezhitsa, I N

    2000-01-01

    The experiments on rats showed for bemithyl LD50 = 581.48 (350.17-965.57) mg/kg and for bromithyl LD50 = 1750.30 (1463.07-2093.92) mg/kg (males) and 1584.29 (1280.46-1960.22) mg/kg (females). The therapeutic ratios are 4-6 for both drugs, while the toxicity index is 10-15 for bemithyl and 20 <196> 22 for bromithyl. It was established that ergotropic effects prevail in the toxicity of bemithyl administered in the 20-80 mg/kg dose range, while trophotropic effects are dominating at doses above 100 mg/kg. Bromithyl exhibits a dose-dependent trophotropic effect in the entire dose range.

  12. Dose Response Data for Hormonally Active Chemicals ...

    EPA Pesticide Factsheets

    The shape of the dose response curve in the low dose region has been debated since the late 1940s. The debate originally focused on linear no threshold (LNT) vs threshold responses in the low dose range for cancer and noncancer related effects. For noncancer effects the default assumption is that noncancer effects generally display threshold rather than LNT responses. More recently, claims have arisen that the chemicals, like endocrine disrupters (EDS), which act via high affinity, low capacity nuclear receptors, may display LNT or nonmonotonic low dose responses: responses that could be missed in multigenerational guideline toxicity testing. This presentation will discuss LNT, threshold and nonmonotonic dose response relationships from case studies of chemicals that disrupt reproductive development and function via the ER, AR and AhR pathways and will include in vitro and in vivo multigenerational data. The in vivo studies in this discussion include only robust, well designed, comprehensive studies that administered the chemical via a relevant route(s) of exposure over a broad dose response range, including low dose(s) in the microgram/kg/d range. The chemicals include ethinyl estradiol, estradiol, genistein, bisphenol a, trenbolone, finasteride, flutamide, phthalate esters and 2,3,7,8 TCDD. The objective is to critically evaluate the data from well done studies in this field to address concerns that current multigenerational reproductive test gui

  13. Non-Malignant Thyroid Diseases Following a Wide Range of Radiation Exposures

    PubMed Central

    Ron, Elaine; Brenner, Alina

    2013-01-01

    Background The thyroid gland is one of the most radiosensitive human organs. While it is well known that radiation exposure increases the risk of thyroid cancer, less is known about its effects in relation to non-malignant thyroid diseases. Objectives The aim of this review is to evaluate the effects of high and low dose radiation on benign structural and functional diseases of the thyroid. Methods We examined the results of major studies from cancer patients treated with high-dose radiotherapy or thyrotoxicosis patients treated with high doses of iodine-131, patients treated with moderate to high dose radiotherapy for benign diseases, persons exposed to low doses from environmental radiation and survivors of the atomic bombings who were exposed to a range of doses. We evaluated radiation effects on structural (tumors, nodules), functional (hyper- and hypothyroidism), and autoimmune thyroid diseases. Results Following a wide range of doses of ionizing radiation, an increased risk of thyroid adenomas and nodules was observed in a variety of populations and settings. The dose response appeared to be linear at low to moderate doses, but in one study there was some suggestion of a reduction in risk above 5 Gy. The elevated risk for benign tumors continues for decades following exposure. Considerably less consistent findings are available regarding functional thyroid diseases including autoimmune diseases. In general, associations for these outcomes were fairly weak and significant radiation effects were most often observed following high doses, particularly for hypothyroidism. Conclusions A significant radiation dose-response relation was demonstrated for benign nodules and follicular adenomas. The effects of radiation on functional thyroid diseases are less clear, partly due to the greater difficulties studying these diseases. PMID:21128812

  14. Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models.

    PubMed

    Tian, Xiaoyu; Li, Xiang; Segars, W Paul; Frush, Donald P; Paulson, Erik K; Samei, Ehsan

    2013-12-21

    Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDI(vol)-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDI(vol)-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.

  15. Dose coefficients in pediatric and adult abdominopelvic CT based on 100 patient models

    NASA Astrophysics Data System (ADS)

    Tian, Xiaoyu; Li, Xiang; Segars, W. Paul; Frush, Donald P.; Paulson, Erik K.; Samei, Ehsan

    2013-12-01

    Recent studies have shown the feasibility of estimating patient dose from a CT exam using CTDIvol-normalized-organ dose (denoted as h), DLP-normalized-effective dose (denoted as k), and DLP-normalized-risk index (denoted as q). However, previous studies were limited to a small number of phantom models. The purpose of this work was to provide dose coefficients (h, k, and q) across a large number of computational models covering a broad range of patient anatomy, age, size percentile, and gender. The study consisted of 100 patient computer models (age range, 0 to 78 y.o.; weight range, 2-180 kg) including 42 pediatric models (age range, 0 to 16 y.o.; weight range, 2-80 kg) and 58 adult models (age range, 18 to 78 y.o.; weight range, 57-180 kg). Multi-detector array CT scanners from two commercial manufacturers (LightSpeed VCT, GE Healthcare; SOMATOM Definition Flash, Siemens Healthcare) were included. A previously-validated Monte Carlo program was used to simulate organ dose for each patient model and each scanner, from which h, k, and q were derived. The relationships between h, k, and q and patient characteristics (size, age, and gender) were ascertained. The differences in conversion coefficients across the scanners were further characterized. CTDIvol-normalized-organ dose (h) showed an exponential decrease with increasing patient size. For organs within the image coverage, the average differences of h across scanners were less than 15%. That value increased to 29% for organs on the periphery or outside the image coverage, and to 8% for distributed organs, respectively. The DLP-normalized-effective dose (k) decreased exponentially with increasing patient size. For a given gender, the DLP-normalized-risk index (q) showed an exponential decrease with both increasing patient size and patient age. The average differences in k and q across scanners were 8% and 10%, respectively. This study demonstrated that the knowledge of patient information and CTDIvol/DLP values may be used to estimate organ dose, effective dose, and risk index in abdominopelvic CT based on the coefficients derived from a large population of pediatric and adult patients.

  16. Limited Impact of Setup and Range Uncertainties, Breathing Motion, and Interplay Effects in Robustly Optimized Intensity Modulated Proton Therapy for Stage III Non-small Cell Lung Cancer.

    PubMed

    Inoue, Tatsuya; Widder, Joachim; van Dijk, Lisanne V; Takegawa, Hideki; Koizumi, Masahiko; Takashina, Masaaki; Usui, Keisuke; Kurokawa, Chie; Sugimoto, Satoru; Saito, Anneyuko I; Sasai, Keisuke; Van't Veld, Aart A; Langendijk, Johannes A; Korevaar, Erik W

    2016-11-01

    To investigate the impact of setup and range uncertainties, breathing motion, and interplay effects using scanning pencil beams in robustly optimized intensity modulated proton therapy (IMPT) for stage III non-small cell lung cancer (NSCLC). Three-field IMPT plans were created using a minimax robust optimization technique for 10 NSCLC patients. The plans accounted for 5- or 7-mm setup errors with ±3% range uncertainties. The robustness of the IMPT nominal plans was evaluated considering (1) isotropic 5-mm setup errors with ±3% range uncertainties; (2) breathing motion; (3) interplay effects; and (4) a combination of items 1 and 2. The plans were calculated using 4-dimensional and average intensity projection computed tomography images. The target coverage (TC, volume receiving 95% of prescribed dose) and homogeneity index (D2 - D98, where D2 and D98 are the least doses received by 2% and 98% of the volume) for the internal clinical target volume, and dose indexes for lung, esophagus, heart and spinal cord were compared with that of clinical volumetric modulated arc therapy plans. The TC and homogeneity index for all plans were within clinical limits when considering the breathing motion and interplay effects independently. The setup and range uncertainties had a larger effect when considering their combined effect. The TC decreased to <98% (clinical threshold) in 3 of 10 patients for robust 5-mm evaluations. However, the TC remained >98% for robust 7-mm evaluations for all patients. The organ at risk dose parameters did not significantly vary between the respective robust 5-mm and robust 7-mm evaluations for the 4 error types. Compared with the volumetric modulated arc therapy plans, the IMPT plans showed better target homogeneity and mean lung and heart dose parameters reduced by about 40% and 60%, respectively. In robustly optimized IMPT for stage III NSCLC, the setup and range uncertainties, breathing motion, and interplay effects have limited impact on target coverage, dose homogeneity, and organ-at-risk dose parameters. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    PubMed

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  18. Clinical pharmacokinetics of Icotinib, an anti-cancer drug: evaluation of dose proportionality, food effect, and tolerability in healthy subjects.

    PubMed

    Liu, Dongyang; Jiang, Ji; Zhang, Li; Tan, Fenlai; Wang, Yingxiang; Zhang, Don; Hu, Pei

    2014-04-01

    Icotinib, an oral epidermal growth factor receptor tyrosine kinase inhibitor, has proved effectiveness in xenografted nude mice. Purpose of the present studies was to investigate tolerability and pharmacokinetics of Icotinib in healthy subjects for the first time, including dose proportionality, food effect, and tolerability. Two studies were conducted in total of 22 healthy subjects: a randomized, two-Latin-square crossover, dose proportional study (n = 12) and a randomized two-way crossover food-effect study (n = 10). Plasma concentration of Icotinib reached peak at a median Tmax of 0.75-3.5 h after single dose and then declined with a mean t1/2β of 6.02-7.83 h. Over the dose range of 100-600 mg, AUC values were proportional to dose and Cmax showed a slight saturation when dose increases. Only 0.2 % of the dose was excreted through kidney in unchanged Icotinib. After dosing 400 mg of Icotinib with high-fat and high-calorie meal, mean Cmax and AUC were significantly increased by 59 and 79 %, respectively. Three subjects experienced four adverse events (rash, increase in AST and ALT, and external injury). Rash and increased levels of AST and ALT were considered as drug-related. No serious adverse events were reported. The current work demonstrated that Icotinib was well tolerated in healthy male subjects (n = 22) over the dose range of 100-600 mg with or without food. Icotinib exposure, expressed in AUC, was proportionally increased with dose over the above dose range. Food intake significantly increased the absorption and exposure of Icotinib in healthy subjects.

  19. Acute changes in the central nervous system of monkeys exposed to protons.

    NASA Technical Reports Server (NTRS)

    Haymaker, W.; Ibrahim, M. Z. M.; Miquel, J.; Call, N.; Noden, P.; Ashley, W.; Ballinger, E. R.; Ghidoni, J.; Lindsay, I. R.; Behar, A. J.

    1972-01-01

    Study of the changes occurring in simian brain exposed to protons of varied energy, given in wide dose and dose-rate ranges. Results show that inflammatory reaction and glycogen accumulation in astrocytes occurred practically in all animals. Cerebral cortical necrosis, granule cell pyknosis, and inflammatory reaction occurred at doses far lower than effective for high-energy gamma radiation given other series of monkeys at comparable dose rates. Metallic impregnation, carried out in virtually all the animals tested, revealed a wide variation in glial response even at equal doses and dose rates in the same proton energy series. Proton energy effect, dose effect, dose-time effect, and dose-rate effect were evident in the various morphological categories investigated, but inconsistencies were encountered.

  20. Evaluation of World Population-Weighted Effective Dose due to Cosmic Ray Exposure

    PubMed Central

    Sato, Tatsuhiko

    2016-01-01

    After the release of the Report of the United Nations Scientific Committee of the Effects of Atomic Radiation in 2000 (UNSCEAR2000), it became commonly accepted that the world population-weighted effective dose due to cosmic-ray exposure is 0.38 mSv, with a range from 0.3 to 2 mSv. However, these values were derived from approximate projections of altitude and geographic dependences of the cosmic-ray dose rates as well as the world population. This study hence re-evaluated the population-weighted annual effective doses and their probability densities for the entire world as well as for 230 individual nations, using a sophisticated cosmic-ray flux calculation model in tandem with detailed grid population and elevation databases. The resulting world population-weighted annual effective dose was determined to be 0.32 mSv, which is smaller than the UNSCEAR’s evaluation by 16%, with a range from 0.23 to 0.70 mSv covering 99% of the world population. These values were noted to vary with the solar modulation condition within a range of approximately 15%. All assessed population-weighted annual effective doses as well as their statistical information for each nation are provided in the supplementary files annexed to this report. These data improve our understanding of cosmic-ray radiation exposures to populations globally. PMID:27650664

  1. Degradation of the Bragg peak due to inhomogeneities.

    PubMed

    Urie, M; Goitein, M; Holley, W R; Chen, G T

    1986-01-01

    The rapid fall-off of dose at the end of range of heavy charged particle beams has the potential in therapeutic applications of sparing critical structures just distal to the target volume. Here we explored the effects of highly inhomogeneous regions on this desirable depth-dose characteristic. The proton depth-dose distribution behind a lucite-air interface parallel to the beam was bimodal, indicating the presence of two groups of protons with different residual ranges, creating a step-like depth-dose distribution at the end of range. The residual ranges became more spread out as the interface was angled at 3 degrees, and still more at 6 degrees, to the direction of the beam. A second experiment showed little significant effect on the distal depth-dose of protons having passed through a mosaic of teflon and lucite. Anatomic studies demonstrated significant effects of complex fine inhomogeneities on the end of range characteristics. Monoenergetic protons passing through the petrous ridges and mastoid air cells in the base of skull showed a dramatic degradation of the distal Bragg peak. In beams with spread out Bragg peaks passing through regions of the base of skull, the distal fall-off from 90 to 20% dose was increased from its nominal 6 to well over 32 mm. Heavy ions showed a corresponding degradation in their ends of range. In the worst case in the base of skull region, a monoenergetic neon beam showed a broadening of the full width at half maximum of the Bragg peak to over 15 mm (compared with 4 mm in a homogeneous unit density medium). A similar effect was found with carbon ions in the abdomen, where the full width at half maximum of the Bragg peak (nominally 5.5 mm) was found to be greater than 25 mm behind gas-soft-tissue interfaces. We address the implications of these data for dose computation with heavy charged particles.

  2. Radiosurgery for Para-IAC Meningiomas: The Effect of Radiation Dose to the Cochlea on Hearing Outcome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Young-Hoon; Department of Neurosurgery, Seoul National University College of Medicine, Seoul; Kim, Dong Gyu, E-mail: gknife@plaza.snu.ac.kr

    2012-11-01

    Purpose: This study was performed to assess the radiosurgical results of meningiomas extending into the internal acoustic canal (para-IAC meningiomas), with a particular focus on the effect of radiation dose to the cochlea on hearing outcome. Methods and Materials: A total of 50 patients who underwent radiosurgery for para-IAC meningiomas between 1998 and 2009, which were followed for 2 years, were enrolled. The mean age was 55.8 years (range, 15-75). The mean tumor volume was 6.1 cm{sup 3} (range, 1.0-19.0), the mean tumor length in the IAC was 6.9 mm (range, 1.3-13.3), and the mean prescribed marginal dose was 13.1more » Gy (range, 10-15) at an isodose line of 50%. The mean follow-up duration was 46 months (range, 24-122). Results: Eight (16.0%) patients had nonserviceable hearing at the time of surgery. At the last follow-up, the tumor control rate was 94%; unchanged in 17 patients, decreased in 30 patients, and increased in 3 patients. Among 42 patients with serviceable hearing at the time of radiosurgery, it was preserved in 41 (97.6%) patients at the last follow-up. The maximal and mean radiation doses to the cochleae of these 41 patients were 5.8 Gy {+-} 0.3 (range, 3.1-11.5) and 4.3 Gy {+-} 0.2 (range, 2.2-7.5), respectively. The maximal dose to the cochlea of the patient who lost hearing after radiosurgery was 4.7 Gy. Conclusions: The radiation dose to the cochlea may have the minimal toxic effect on the hearing outcome in patients who undergo radiosurgery for para-IAC meningiomas.« less

  3. Patient-specific dose estimation for pediatric abdomen-pelvis CT

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Sturgeon, Gregory M.; Colsher, James G.; Frush, Donald P.

    2009-02-01

    The purpose of this study is to develop a method for estimating patient-specific dose from abdomen-pelvis CT examinations and to investigate dose variation across patients in the same weight group. Our study consisted of seven pediatric patients in the same weight/protocol group, for whom full-body computer models were previously created based on the patients' CT data obtained for clinical indications. Organ and effective dose of these patients from an abdomen-pelvis scan protocol (LightSpeed VCT scanner, 120-kVp, 85-90 mA, 0.4-s gantry rotation period, 1.375-pitch, 40-mm beam collimation, and small body scan field-of-view) was calculated using a Monte Carlo program previously developed and validated for the same CT system. The seven patients had effective dose of 2.4-2.8 mSv, corresponding to normalized effective dose of 6.6-8.3 mSv/100mAs (coefficient of variation: 7.6%). Dose variations across the patients were small for large organs in the scan coverage (mean: 6.6%; range: 4.9%-9.2%), larger for small organs in the scan coverage (mean: 10.3%; range: 1.4%-15.6%), and the largest for organs partially or completely outside the scan coverage (mean: 14.8%; range: 5.7%-27.7%). Normalized effective dose correlated strongly with body weight (correlation coefficient: r = -0.94). Normalized dose to the kidney and the adrenal gland correlated strongly with mid-liver equivalent diameter (kidney: r = -0.97; adrenal glands: r = -0.98). Normalized dose to the small intestine correlated strongly with mid-intestine equivalent diameter (r = -0.97). These strong correlations suggest that patient-specific dose may be estimated for any other child in the same size group who undergoes the abdomen-pelvis scan.

  4. SU-F-J-197: A Novel Intra-Beam Range Detection and Adaptation Strategy for Particle Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, M; Jiang, S; Shao, Y

    2016-06-15

    Purpose: In-vivo range detection/verification is crucial in particle therapy for effective and safe delivery. The state-of-art techniques are not sufficient for in-vivo on-line range verification due to conflicts among patient dose, signal statistics and imaging time. We propose a novel intra-beam range detection and adaptation strategy for particle therapy. Methods: This strategy uses the planned mid-range spots as probing beams without adding extra radiation to patients. Such choice of probing beams ensures the Bragg peaks to remain inside the tumor even with significant range variation from the plan. It offers sufficient signal statistics for in-beam positron emission tomography (PET) duemore » to high positron activity of therapeutic dose. The probing beam signal can be acquired and reconstructed using in-beam PET that allows for delineation of the Bragg peaks and detection of range shift with ease of detection enabled by single-layered spots. If the detected range shift is within a pre-defined tolerance, the remaining spots will be delivered as the original plan. Otherwise, a fast re-optimization using range-shifted beamlets and accounting for the probing beam dose is applied to consider the tradeoffs posed by the online anatomy. Simulated planning and delivery studies were used to demonstrate the effectiveness of the proposed techniques. Results: Simulations with online range variations due to shifts of various foreign objects into the beam path showed successful delineation of the Bragg peaks as a result of delivering probing beams. Without on-line delivery adaptation, dose distribution was significantly distorted. In contrast, delivery adaptation incorporating detected range shift recovered well the planned dose. Conclusion: The proposed intra-beam range detection and adaptation utilizing the planned mid-range spots as probing beams, which illuminate the beam range with strong and accurate PET signals, is a safe, practical, yet effective approach to address range uncertainty issues in particle therapy.« less

  5. Environmental standards for ionizing radiation: theoretical basis for dose-response curves.

    PubMed Central

    Upton, A C

    1983-01-01

    The types of injury attributable to ionizing radiation are subdivided, for purposes of risk assessment and radiological protection, into two broad categories: stochastic effects and nonstochastic effects. Stochastic effects are viewed as probablistic phenomena, varying in frequency but not severity as a function of the dose, without any threshold; nonstochastic effects are viewed as deterministic phenomena, varying in both frequency and severity as a function of the dose, with clinical thresholds. Included among stochastic effects are heritable effects (mutations and chromosome aberrations) and carcinogenic effects. Both types of effects are envisioned as unicellular phenomena which can result from nonlethal injury of individual cells, without the necessity of damage to other cells. For the induction of mutations and chromosome aberrations in the low-to-intermediate dose range, the dose-response curve with high-linear energy transfer (LET) radiation generally conforms to a linear nonthreshold relationship and varies relatively little with the dose rate. In contrast, the curve with low-LET radiation generally conforms to a linear-quadratic relationship, rising less steeply than the curve with high-LET radiation and increasing in slope with increasing dose and dose rate. The dose-response curve for carcinogenic effects varies widely from one type of neoplasm to another in the intermediate-to-high dose range, in part because of differences in the way large doses of radiation can affect the promotion and progression of different neoplasms. Information about dose-response relations for low-level irradiation is fragmentary but consistent, in general, with the hypothesis that the neoplastic transformation may result from mutation, chromosome aberration or genetic recombination in a single susceptible cell. PMID:6653536

  6. Acute ethanol ingestion produces dose-dependent effects on motor behavior in the honey bee (Apis mellifera).

    PubMed

    Maze, Ian S; Wright, Geraldine A; Mustard, Julie A

    2006-01-01

    Ethanol consumption produces characteristic behavioral states in animals that include sedation, disorientation, and disruption of motor function. Using individual honey bees, we assessed the effects of ethanol ingestion on motor function via continuous observations of their behavior. Consumption of 1 M sucrose solutions containing a range of ethanol doses led to hemolymph ethanol levels of approximately 40-100 mM. Using ethanol doses in this range, we observed time and dose-dependent effects of ethanol on the percent of time our subjects spent walking, stopped, or upside down, and on the duration and frequency of bouts of behavior. The effects on grooming and flying behavior were more complex. Behavioral recovery from ethanol treatment was both time and ethanol dose dependent, occurring between 12 and 24 h post-ingestion for low doses and at 24-48 h for higher doses. Furthermore, the amount of ethanol measured in honey bee hemolymph appeared to correlate with recovery. We predict that the honey bee will prove to be an excellent model system for studying the influence of ethanol on the neural mechanisms underlying behavior.

  7. Cumulative doses analysis in young trauma patients: a single-centre experience.

    PubMed

    Salerno, Sergio; Marrale, Maurizio; Geraci, Claudia; Caruso, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio; Midiri, Massimo

    2016-02-01

    Multidetector computed tomography (MDCT) represents the main source of radiation exposure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT studies have been observed in the young trauma population with an increase in radiation exposure. We have identified 249 young adult patients (178 men and 71 women; age range 14-40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radiological Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software(®). We have observed a mean cumulative dose of about 27 mSv (range from 3 to 297 mSv). The distribution analysis is characterised by low effective dose, below 20 mSv, in the majority of the patients. However, in 29 patients, the effective dose was found to be higher than 20 mSv. Dose distribution for the various organs analysed (breasts, ovaries, testicles, heart and eye lenses) shows an intense peak for lower doses, but in some cases high doses were recorded. Even though cumulative doses may have long-term effects, which are still under debate, high doses are observed in this specific group of young patients.

  8. Arterial gastroduodenal infusion of cholecystokinin-33 stimulates the exocrine pancreatic enzyme release via an enteropancreatic reflex, without affecting the endocrine insulin secretion in pigs.

    PubMed

    Rengman, Sofia; Weström, Björn; Ahrén, Bo; Pierzynowski, Stefan G

    2009-03-01

    Cholecystokinin (CCK)-dependent exocrine pancreatic regulation seems to involve different pathways in different species. The aims were to explore the enteropancreatic reflex in the CCK-mediated regulation of the exocrine pancreas and to evaluate a possible involvement of this reflex in the endocrine insulin release. In anesthetized pigs, CCK-33 in increasing doses (4-130 pmol kg 10 min) was infused locally to the gastroduodenal artery, or systemically via the jugular vein. Also, a low CCK-33 dose (13 pmol kg) was injected to the duodenum/antrum area before and after a bilateral truncal vagotomy. Cholecystokinin-33 in the physiological dose range 4 to 32 pmol kg 10 min increased protein and trypsin outputs after local infusion to the antral-duodenal area, whereas it had no effect after systemic infusion. Cholecystokinin-33 in the pharmacological dose range 64 to 130 pmol kg 10 min further increased the secretion after both local and systemic infusions. Only CCK-33 infusions in the pharmacological dose range were able to elevate the plasma insulin levels. Vagotomy had no effect on CCK-33-mediated stimulation of the enzyme release, whereas it had a significant effect on the plasma insulin level. Cholecystokinin-33 in the physiological dose range 4 to 32 pmol kg 10 min stimulates the enzyme secretion but had no effect on the insulin release via a short enteropancreatic pathway in pigs.

  9. Safety and efficacy of intravenous administration for tranexamic acid-induced emesis in dogs with accidental ingestion of foreign substances.

    PubMed

    Orito, Kensuke; Kawarai-Shimamura, Asako; Ogawa, Atsushi; Nakamura, Atsushi

    2017-12-22

    A prospective observational study was performed in canine clinical medicine to evaluate the emetic action and adverse effects of tranexamic acid. Veterinarians treated 137 dogs with a single dose of tranexamic acid (50 mg/kg, IV) after accidental ingestion of foreign substances. If needed, a second (median, 50 mg/kg; range, 20-50 mg/kg, IV) or third dose (median, 50 mg/kg; range, 25-50 mg/kg, IV) was administered. Tranexamic acid induced emesis in 116 of 137 (84.7%) dogs. Median time to onset of emesis was 116.5 sec (range, 26-370 sec), median duration of emesis was 151.5 sec (range, 30-780 sec), and median number of emesis episodes was 2 (range, 1-8). Second and third administrations of tranexamic acid induced emesis in 64.7 and 66.7% of dogs, respectively. In total, IV administration of tranexamic acid successfully induced emesis in 129 of 137 (94.2%) dogs. Adverse effects included a tonic-clonic convulsion and hemostatic disorder in two different dogs, both of which recovered after receiving medical care. Tranexamic acid induced emesis in most dogs following a single-dose. When a single dose was not sufficient, an additional dosage effectively induced emesis. Overall, adverse effects were considered low and self-limiting.

  10. Cost-effectiveness of pharmacogenetics-guided warfarin therapy vs. alternative anticoagulation in atrial fibrillation.

    PubMed

    Pink, J; Pirmohamed, M; Lane, S; Hughes, D A

    2014-02-01

    Pharmacogenetics-guided warfarin dosing is an alternative to standard clinical algorithms and new oral anticoagulants for patients with nonvalvular atrial fibrillation. However, clinical evidence for pharmacogenetics-guided warfarin dosing is limited to intermediary outcomes, and consequently, there is a lack of information on the cost-effectiveness of anticoagulation treatment options. A clinical trial simulation of S-warfarin was used to predict times within therapeutic range for different dosing algorithms. Relative risks of clinical events, obtained from a meta-analysis of trials linking times within therapeutic range with outcomes, served as inputs to an economic analysis. Neither dabigatran nor rivaroxaban were cost-effective options. Along the cost-effectiveness frontier, in relation to clinically dosed warfarin, pharmacogenetics-guided warfarin and apixaban had incremental cost-effectiveness ratios of £13,226 and £20,671 per quality-adjusted life year gained, respectively. On the basis of our simulations, apixaban appears to be the most cost-effective treatment.

  11. A dose ranging study of ibuprofen suspension as an antipyretic.

    PubMed Central

    Marriott, S C; Stephenson, T J; Hull, D; Pownall, R; Smith, C M; Butler, A

    1991-01-01

    A double blind trial was conducted to determine the dose of ibuprofen suspension, which is effective in reducing the body temperature. The principal measure of efficacy was a reduction in axillary temperature of 1 degree C or more three hours after dosing. A second objective of the trial was to compare the incidence and severity of side effects and the palatability of a range of ibuprofen doses. Ninety three children were included in the analysis. All four doses of ibuprofen studied (0.625 mg/kg-5 mg/kg) were associated with temperature reduction and only the lowest dose failed to satisfy the principal measure of efficacy. The influence of dose on the magnitude of the body temperature reduction was significant and the 5 mg/kg dose achieved the largest mean reduction in body temperature (2 degrees C). The tolerability and palatability of all doses studied were excellent. These findings suggest that ibuprofen is a good alternative to paracetamol as an antipyretic. PMID:1929509

  12. Organ dose assessment in pediatric fluoroscopy and CT via a tomographic computational phantom of the newborn patient

    NASA Astrophysics Data System (ADS)

    Staton, Robert J.

    Of the various types of imaging modalities used in pediatric radiology, fluoroscopy and computed tomography (CT) have the highest associated radiation dose. While these examinations are commonly used for pediatric patients, little data exists on the magnitude of the organ and effective dose values for these procedures. Calculation of these dose values is necessary because of children's increased sensitivity to radiation and their long life expectancy for which to express radiation's latent effects. In this study, a newborn tomographic phantom has been implemented in a radiation transport code to evaluate organ and effective doses for newborn patients in commonly performed fluoroscopy and CT examinations. Organ doses were evaluated for voiding cystourethrogram (VCUG) fluoroscopy studies of infant patients. Time-sequence analysis was performed for videotaped VCUG studies of five different patients. Organ dose values were then estimated for each patient through Monte Carlo (MC) simulations. The effective dose values of the VCUG examination for five patients ranged from 0.6 mSv to 3.2 mSv, with a mean of 1.8 +/- 0.9 mSv. Organ doses were also assessed for infant upper gastrointestinal (UGI) fluoroscopy exams. The effective dose values of the UGI examinations for five patients ranged from 1.05 mSv to 5.92 mSv, with a mean of 2.90 +/- 1.97 mSv. MC simulations of helical multislice CT (MSCT) exams were also completed using, the newborn tomographic phantom and a stylized newborn phantom. The helical path of the source, beam shaping filter, beam profile, patient table, were all included in the MC simulations of the helical MSCT scanner. Organ doses and effective doses and their dependence on scan parameters were evaluated for newborn patients. For all CT scans, the effective dose was found to range approximately 1-13 mSv, with the largest values occurring for CAP scans. Tube current modulation strategies to reduce patient dose were also evaluated for newborn patients. Overall, utilization of the newborn tomographic phantom in MC simulations has shown the need for and usefulness of pediatric tomographic phantoms. The newborn tomographic model has shown more versatility and realistic anatomical modeling when compared to the existing stylized newborn phantom. This work has provided important organ dose data for infant patients in common examinations in pediatric radiology.

  13. Cytogenetic effect of low dose gamma-radiation in Hordeum vulgare seedlings: non-linear dose-effect relationship.

    PubMed

    Geras'kin, Stanislav A; Oudalova, Alla A; Kim, Jin Kyu; Dikarev, Vladimir G; Dikareva, Nina S

    2007-03-01

    The induction of chromosome aberrations in Hordeum vulgare germinated seeds was studied after ionizing irradiation with doses in the range of 10-1,000 mGy. The relationship between the frequency of aberrant cells and the absorbed dose was found to be nonlinear. A dose-independent plateau in the dose range from about 50 to 500 mGy was observed, where the level of cytogenetic damage was significantly different from the spontaneous level. The comparison of the goodness of the experimental data fitting with mathematical models of different complexity, using the most common quantitative criteria, demonstrated the advantage of a piecewise linear model over linear and polynomial models in approximating the frequency of cytogenetical disturbances. The results of the study support the hypothesis of indirect mechanisms of mutagenesis induced by low doses. Fundamental and applied implications of these findings are discussed.

  14. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, Bria M.; Brady, Samuel L., E-mail: samuel.brady@stjude.org; Kaufman, Robert A.

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (CF{sub SSDE}{sup organ}) were then multiplied by patient-specific SSDE to estimate patient organ dose. Themore » CF{sub SSDE}{sup organ} were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. IndividualCF{sub SSDE}{sup organ} were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and CF{sub SSDE}{sup organ}, was compared to previously published pediatric patient doses that accounted for patient size in their dose calculation, and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusions: For organs fully covered within the scan volume, the average correlation of SSDE and organ absolute dose was found to be better than ±10%. In addition, this study provides a complete list of organ dose correlation factors (CF{sub SSDE}{sup organ}) for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.« less

  15. Radon Exposure and the Definition of Low Doses-The Problem of Spatial Dose Distribution.

    PubMed

    Madas, Balázs G

    2016-07-01

    Investigating the health effects of low doses of ionizing radiation is considered to be one of the most important fields in radiological protection research. Although the definition of low dose given by a dose range seems to be clear, it leaves some open questions. For example, the time frame and the target volume in which absorbed dose is measured have to be defined. While dose rate is considered in the current system of radiological protection, the same cancer risk is associated with all exposures, resulting in a given amount of energy absorbed by a single target cell or distributed among all the target cells of a given organ. However, the biological effects and so the health consequences of these extreme exposure scenarios are unlikely to be the same. Due to the heterogeneous deposition of radon progeny within the lungs, heterogeneous radiation exposure becomes a practical issue in radiological protection. While the macroscopic dose is still within the low dose range, local tissue doses on the order of Grays can be reached in the most exposed parts of the bronchial airways. It can be concluded that progress in low dose research needs not only low dose but also high dose experiments where small parts of a biological sample receive doses on the order of Grays, while the average dose over the whole sample remains low. A narrow interpretation of low dose research might exclude investigations with high relevance to radiological protection. Therefore, studies important to radiological protection should be performed in the frame of low dose research even if the applied doses do not fit in the dose range used for the definition of low doses.

  16. Limited Impact of Setup and Range Uncertainties, Breathing Motion, and Interplay Effects in Robustly Optimized Intensity Modulated Proton Therapy for Stage III Non-small Cell Lung Cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Inoue, Tatsuya; Widder, Joachim; Dijk, Lisanne V. van

    2016-11-01

    Purpose: To investigate the impact of setup and range uncertainties, breathing motion, and interplay effects using scanning pencil beams in robustly optimized intensity modulated proton therapy (IMPT) for stage III non-small cell lung cancer (NSCLC). Methods and Materials: Three-field IMPT plans were created using a minimax robust optimization technique for 10 NSCLC patients. The plans accounted for 5- or 7-mm setup errors with ±3% range uncertainties. The robustness of the IMPT nominal plans was evaluated considering (1) isotropic 5-mm setup errors with ±3% range uncertainties; (2) breathing motion; (3) interplay effects; and (4) a combination of items 1 and 2.more » The plans were calculated using 4-dimensional and average intensity projection computed tomography images. The target coverage (TC, volume receiving 95% of prescribed dose) and homogeneity index (D{sub 2} − D{sub 98}, where D{sub 2} and D{sub 98} are the least doses received by 2% and 98% of the volume) for the internal clinical target volume, and dose indexes for lung, esophagus, heart and spinal cord were compared with that of clinical volumetric modulated arc therapy plans. Results: The TC and homogeneity index for all plans were within clinical limits when considering the breathing motion and interplay effects independently. The setup and range uncertainties had a larger effect when considering their combined effect. The TC decreased to <98% (clinical threshold) in 3 of 10 patients for robust 5-mm evaluations. However, the TC remained >98% for robust 7-mm evaluations for all patients. The organ at risk dose parameters did not significantly vary between the respective robust 5-mm and robust 7-mm evaluations for the 4 error types. Compared with the volumetric modulated arc therapy plans, the IMPT plans showed better target homogeneity and mean lung and heart dose parameters reduced by about 40% and 60%, respectively. Conclusions: In robustly optimized IMPT for stage III NSCLC, the setup and range uncertainties, breathing motion, and interplay effects have limited impact on target coverage, dose homogeneity, and organ-at-risk dose parameters.« less

  17. Effective dose estimation for pediatric upper gastrointestinal examinations using an anthropomorphic phantom set and metal oxide semiconductor field-effect transistor (MOSFET) technology.

    PubMed

    Emigh, Brent; Gordon, Christopher L; Connolly, Bairbre L; Falkiner, Michelle; Thomas, Karen E

    2013-09-01

    There is a need for updated radiation dose estimates in pediatric fluoroscopy given the routine use of new dose-saving technologies and increased radiation safety awareness in pediatric imaging. To estimate effective doses for standardized pediatric upper gastrointestinal (UGI) examinations at our institute using direct dose measurement, as well as provide dose-area product (DAP) to effective dose conversion factors to be used for the estimation of UGI effective doses for boys and girls up to 10 years of age at other centers. Metal oxide semiconductor field-effect transistor (MOSFET) dosimeters were placed within four anthropomorphic phantoms representing children ≤10 years of age and exposed to mock UGI examinations using exposures much greater than used clinically to minimize measurement error. Measured effective dose was calculated using ICRP 103 weights and scaled to our institution's standardized clinical UGI (3.6-min fluoroscopy, four spot exposures and four examination beam projections) as determined from patient logs. Results were compared to Monte Carlo simulations and related to fluoroscope-displayed DAP. Measured effective doses for standardized pediatric UGI examinations in our institute ranged from 0.35 to 0.79 mSv in girls and were 3-8% lower for boys. Simulation-derived and measured effective doses were in agreement (percentage differences <19%, T > 0.18). DAP-to-effective dose conversion factors ranged from 6.5 ×10(-4) mSv per Gy-cm(2) to 4.3 × 10(-3) mSv per Gy-cm(2) for girls and were similarly lower for boys. Using modern fluoroscopy equipment, the effective dose associated with the UGI examination in children ≤10 years at our institute is < 1 mSv. Estimations of effective dose associated with pediatric UGI examinations can be made for children up to the age of 10 using the DAP-normalized conversion factors provided in this study. These estimates can be further refined to reflect individual hospital examination protocols through the use of direct organ dose measurement using MOSFETs, which were shown to agree with Monte Carlo simulated doses.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Battum, LJ van; Heukelom, S

    Purpose This study investigates the origin of lateral optical density (OD) variation for Gafchromic film (EBT and EBT2) scanned in transmission mode with Epson flatbed scanners (1680 Expression Pro and 10000XL). Effects investigated are: cross talk, optical path length and polarization. Methods Cross talk has been examined with triangular shaped light-transmission sheets with OD ranging from 0 to opaque. Optical path length has been studied with absorptive and reflective OD-filters (OD range 0.2 to 2.0). Dependency on light-polarization on the scanner read out has been investigated using linear polarizer sheets. All experiments have been performed at centre scanner position (normmore » point) and at several lateral scan positions, without and with (un)irradiated EBT-film. Dose values used ranged between 0.2 to 9 Gy, yielding an OD-range between 0.25 to 1.1. Results The lateral OD variation is dose dependent and increases up to 14% at most lateral position for dose up to 9 Gy. Cross talk effect contributes to 0.5% in clinical used OD ranges but equals 2% for extreme high dose gradients. Film induced optical path length will effect the lateral OD variation up to 3% at most lateral points. Light polarization is inherent present in these scanners due to multiple reflection on mirrors. In addition film induced polarization is the most important effect generating the observed lateral OD variation. Both Gafchromic film base and sensitive layer have polarizing capabilities; for the sensitive layer its influence is dose dependent. Conclusions Lateral OD variation origins from optical physics (i.e. polarization and reflection) related to scanner and film construction. Cross talk can be ignored in film dosimetry for clinical used dose values and gradients. Therefore it is recommended to determine the lateral OD variation per film type and scanner.« less

  19. Dose-ranging pharmacokinetics of colistin methanesulphonate (CMS) and colistin in rats following single intravenous CMS doses.

    PubMed

    Marchand, Sandrine; Lamarche, Isabelle; Gobin, Patrice; Couet, William

    2010-08-01

    The aim of this study was to evaluate the effect of colistin methanesulphonate (CMS) dose on CMS and colistin pharmacokinetics in rats. Three rats per group received an intravenous bolus of CMS at a dose of 5, 15, 30, 60 or 120 mg/kg. Arterial blood samples were drawn at 0, 5, 15, 30, 60, 90, 120, 150 and 180 min. CMS and colistin plasma concentrations were determined by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The pharmacokinetic parameters of CMS and colistin were calculated by non-compartmental analysis. Linear relationships were observed between CMS and colistin AUCs to infinity and CMS doses, as well as between CMS and colistin C(max) and CMS doses. CMS and colistin pharmacokinetics were linear for a range of colistin concentrations covering the range of values encountered and recommended in patients even during treatment with higher doses.

  20. Pharmacologically active phenylpropanoids from Senra incana.

    PubMed

    Farah, M H; Samuelsson, G

    1992-02-01

    Coniferaldehyde, scopoletin, sinapaldehyde, and syringaldehyde were isolated from an aqueous extract of Senra incana. All four compounds inhibited prostaglandin synthetase in a dose-dependent way. Compared to aspirin, the potency of coniferaldehyde and scopoletin was about five times higher, whereas syringaldehyde and sinapaldehyde had about half the potency of this reference compound. On topical application, sinapaldehyde and scopoletin dose-dependently inhibited ethyl phenylpropiolate-induced edema of the rat ear. The active dose range was 1-10 micrograms/ear. Higher doses had a lower effect. Syringaldehyde was active in the range 20-100 micrograms/ear, whereas the effect of coniferaldehyde was inconclusive. Coniferaldehyde and sinapaldehyde inhibited electrically induced contractions of the guinea pig ileum in a dose-dependent way. Syringaldehyde showed a weak inhibition at a concentration of 550 microM.

  1. SU-F-I-40: Impact of Scan Length On Patient Dose in Abdomen/pelvis CT Diagnosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, I; Song, J; Kim, K

    Purpose: To analysis the impact of scan length on patient doses in abdomen/pelvis CT diagnosis of each hospital. Methods: Scan length of 7 hospitals from abdomen/pelvis CT diagnosis was surveyed in Korea. Surveyed scan lengths were additional distance above diaphragm and distance below pubic symphysis except for standard scan range between diaphragm and pubic symphysis. Patient dose was estimated for adult male and female according to scan length of each hospital. CT-Expo was used to estimate the patient dose under identical equipment settings (120 kVp, 100 mAs, 10 mm collimation width, etc.) except scan length. Effective dose was calculated bymore » using tissue weighting factor of ICRP 103 recommendation. Increase rate of effective dose was calculated comparing with effective dose of standard scan range Results: Scan lengths of abdomen/pelvis CT diagnosis of each hospital were different. Also effective dose was increased with increasing the scan length. Generally increasing the distance above diaphragm caused increase of effective dose of male and female, but increasing the distance below pubic symphysis caused increase of effective dose of male. Conclusion: We estimated the patient dose according to scan length of each hospital in abdomen/pelvis CT diagnosis. Effective dose was increased by increasing the scan length because dose of organs with high tissue weighting factor such as lung, breast, testis were increased. Scan length is important factor on patient dose in CT diagnosis. If radiologic technologist interested in patient dose, decreasing the unnecessary scan length will decrease the risk of patients from radiation. This research was supported by a grant of the Korea Health Technology R&D Project through the Korea Health Industry Development Institute (KHIDI), funded by the Ministry of Health & Welfare, Republic of Korea (grant number: HI13C0004).« less

  2. Intravenous paracetamol with a lower dose is also effective for the treatment of patent ductus arteriosus in pre-term infants.

    PubMed

    Tekgündüz, Kadir Şerafettin; Ceviz, Naci; Caner, İbrahim; Olgun, Haşim; Demirelli, Yaşar; Yolcu, Canan; Şahin, İrfan Oğuz; Kara, Mustafa

    2015-08-01

    Haemodynamically significant patent ductus arteriosus is a significant cause of morbidity and mortality in pre-term infants. This retrospective study was conducted to investigate the usefulness of lower-dose paracetamol for the treatment of patent ductus arteriosus in pre-term infants. A total of 13 pre-term infants who received intravenous paracetamol because of contrindications or side effects to oral ibuprofen were retrospectively enrolled. In the first patient, the dose regimen was 15 mg/kg/dose, every 6 hours. As the patient developed significant elevation in transaminase levels, the dose was decreased to 10 mg/kg/dose, every 8 hours in the following 12 patients. Echocardiographic examination was conducted daily. In case of closure, it was repeated after 2 days and when needed thereafter in terms of reopening. A total of 13 patients received intravenous paracetamol. Median gestational age was 29 weeks ranging from 24 to 31 weeks and birth weight was 950 g ranging from 470 to 1390 g. The median postnatal age at the first intravenous paracetamol dose was 3 days ranging from 2 to 9 days. In 10 of the 13 patients (76.9%), patent ductus arteriosus was closed at the median 2nd day of intravenous paracetamol ranging from 1 to 4 days. When the patient who developed hepatotoxicity was eliminated, the closure rate was found to be 83.3% (10/12). Intravenous paracetamol may be a useful treatment option for the treatment of patent ductus arteriosus in pre-term infants with contrindication to ibuprofen. In our experience, lower-dose paracetamol is effective in closing the patent ductus arteriosus in 83.3% of the cases.

  3. Acute ethanol ingestion produces dose-dependent effects on motor behavior in the honey bee (Apis mellifera)

    PubMed Central

    Maze, Ian S.; Wright, Geraldine A.; Mustard, Julie A.

    2006-01-01

    Ethanol consumption produces characteristic behavioral states in animals that include sedation, disorientation, and disruption of motor function. Using individual honey bees, we assessed the effects of ethanol ingestion on motor function via continuous observations of their behavior. Consumption of 1 M sucrose solutions containing a range of ethanol doses lead to hemolymph ethanol levels of approximately 40 to 100 mM. Using ethanol doses in this range, we observed time and dose-dependent effects of ethanol on the percent of time our subjects spent walking, stopped, or upside down, and on the duration and frequency of bouts of behavior. The effects on grooming and flying behavior were more complex. Behavioral recovery from ethanol treatment was both time and ethanol dose dependent, occurring between 12 and 24 hr post-ingestion for low doses and at 24 to 48 hours for higher doses. Furthermore, the amount of ethanol measured in honey bee hemolymph appeared to correlate with recovery. We predict that the honey bee will prove to be an excellent model system for studying the influence of ethanol on the neural mechanisms underlying behavior. PMID:17070538

  4. Over-scanning in chest CT: Comparison of practice among six hospitals and its impact on radiation dose.

    PubMed

    Schwartz, Fides; Stieltjes, Bram; Szucs-Farkas, Zsolt; Euler, André

    2018-05-01

    Compare incidence of over-scanning in chest CT among six hospitals and impact on effective and organ effective radiation dose. Scout images of 600 chest CTs from six hospitals (A-F) were retrospectively reviewed using a radiation dose tracking software (RTS). Optimal scan range was determined and compared to the actual scan range. Incidence of cranial and caudal over-scanning was assessed and changes in total and organ effective dose were calculated. Descriptive statistics, Tukey- and Wilcoxon matched pairs test were applied. Simultaneous cranial and caudal over-scanning occurred in 29 of 600 scans (A = 0%, B = 1%, C = 12%, D = 3%, E = 11%, F = 2%). Effective radiation dose increased on average by 0.29 mSv (P < 0.001). Cranial over-scanning was observed in 45 of 600 scans (A = 0%, B = 8%, C = 2%, D = 15%, E = 17%, F = 3%) and increased organ effective dose by 0.35 mSv in the thyroid gland (P < 0.001). Caudal over-scanning occurred in 147 of 600 scans (A = 7%, B = 9%, C = 35%, D = 4%, E = 32%, F = 60%) and increased organ effective doses in the upper abdomen by up to 14% (P < 0.001 for all organs). Substantial differences in the incidence of over-scanning in chest CT exist among different hospitals. These differences result in excessive effective radiation dose and increased individual organ effective doses in patients. Copyright © 2018 Elsevier B.V. All rights reserved.

  5. 32 CFR 218.3 - Dose reconstruction methodology.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... effects of shot-specific parameters such as weapon type and yield, neutron and gamma output, source and... specific personnel activities. Due to the range of activities, times, geometries, shielding, and weapon... that could have led to atypical doses. Radiation dose from neutrons and dose commitments due to inhaled...

  6. 32 CFR 218.3 - Dose reconstruction methodology.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... effects of shot-specific parameters such as weapon type and yield, neutron and gamma output, source and... specific personnel activities. Due to the range of activities, times, geometries, shielding, and weapon... that could have led to atypical doses. Radiation dose from neutrons and dose commitments due to inhaled...

  7. 32 CFR 218.3 - Dose reconstruction methodology.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... effects of shot-specific parameters such as weapon type and yield, neutron and gamma output, source and... specific personnel activities. Due to the range of activities, times, geometries, shielding, and weapon... that could have led to atypical doses. Radiation dose from neutrons and dose commitments due to inhaled...

  8. SU-F-T-194: Analyzing the Effect of Range Shifter Air Gap On TPS Dose Modeling Accuracy in Superficial PBS Proton Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shirey, R; Wu, H

    2016-06-15

    Purpose: Treatment planning systems (TPS) may not accurately model superficial dose distributions of range shifted proton pencil beam scanning (PBS) treatments. Numerous patient-specific QA tests performed on superficially treated PBS plans have shown a consistent overestimate of dose by the TPS. This study quantifies variations between TPS planned dose and measured dose as a function of range shifter air gap and treatment depths up to 5 cm. Methods: PBS treatment plans were created in the TPS to uniformly irradiate a volume of solid water. One plan was created for each range shifter position analyzed, and all plans utilized identical dosemore » optimization parameters. Each optimized plan was analyzed in the TPS to determine the planned dose at varying depths. A PBS proton therapy system with a 3.5 cm lucite range shifter delivered the treatment plans, and a parallel plate chamber embedded in RW3 solid water measured dose at shallow depths for each air gap. Differences between measured and planned doses were plotted and analyzed. Results: The data show that the TPS more accurately models superficial dose as the air gap between the range shifter and patient surface decreases. Air gaps less than 10 cm have an average dose difference of only 1.6%, whereas air gaps between 10 and 20 cm differ by 3.0% and gaps greater than 20 cm differ by 4.4%. Conclusion: This study has shown that the TPS is unable to accurately model superficial dose with a large range shifter air gap. Dose differences greater than 3% will likely cause QA failure, as many institutions analyze patient QA with a 3%/3mm gamma analysis. For superficial PBS therapy, range shifter positions should be chosen to keep the air gap less then 10 cm when patient setup and gantry geometry allow.« less

  9. Proton therapy of prostate cancer by anterior-oblique beams: implications of setup and anatomy variations

    NASA Astrophysics Data System (ADS)

    Moteabbed, M.; Trofimov, A.; Sharp, G. C.; Wang, Y.; Zietman, A. L.; Efstathiou, J. A.; Lu, H.-M.

    2017-03-01

    Proton therapy of prostate by anterior beams could offer an attractive option for treating patients with hip prosthesis and limiting the high-dose exposure to the rectum. We investigated the impact of setup and anatomy variations on the anterior-oblique (AO) proton plan dose, and strategies to manage these effects via range verification and adaptive delivery. Ten patients treated by bilateral (BL) passive-scattering proton therapy (79.2 Gy in 44 fractions) who underwent weekly verification CT scans were selected. Plans with AO beams were additionally created. To isolate the effect of daily variations, initial AO plans did not include range uncertainty margins. The use of fixed planning margins and adaptive range adjustments to manage these effects was investigated. For each case, the planned dose was recalculated on weekly CTs, and accumulated on the simulation CT using deformable registration to approximate the delivered dose. Planned and accumulated doses were compared for each scenario to quantify dose deviations induced by variations. The possibility of estimating the necessary range adjustments before each treatment was explored by simulating the procedure of a diode-based in vivo range verification technique, which would potentially be used clinically. The average planned rectum, penile bulb and femoral heads mean doses were smaller for initial AO compared to BL plans (by 8.3, 16.1 and 25.9 Gy, respectively). After considering interfractional variations in AO plans, the target coverage was substantially reduced. The maximum reduction of V 79.2/D 95/D mean/EUD for AO (without distal margins) (25.3%/10.7/1.6/4.9 Gy, respectively) was considerably larger than BL plans. The loss of coverage was mainly related to changes in water equivalent path length of the prostate after fiducial-based setup, caused by discrepancies in patient anterior surface and bony-anatomy alignment. Target coverage was recovered partially when using fixed planning margins, and fully when applying adaptive range adjustments. The accumulated organs-at-risk dose for AO beams after range adjustment demonstrated full sparing of femoral heads and superior sparing of penile bulb and rectum compared to the conventional BL cases. Our study indicates that using AO beams makes prostate treatment more susceptible to target underdose induced by interfractional variations. Adaptive range verification/adjustment may facilitate the use of anterior beam approaches, and ensure adequate target coverage in every fraction of the treatment.

  10. Safety and efficacy of intravenous administration for tranexamic acid-induced emesis in dogs with accidental ingestion of foreign substances

    PubMed Central

    ORITO, Kensuke; KAWARAI-SHIMAMURA, Asako; OGAWA, Atsushi; NAKAMURA, Atsushi

    2017-01-01

    A prospective observational study was performed in canine clinical medicine to evaluate the emetic action and adverse effects of tranexamic acid. Veterinarians treated 137 dogs with a single dose of tranexamic acid (50 mg/kg, IV) after accidental ingestion of foreign substances. If needed, a second (median, 50 mg/kg; range, 20–50 mg/kg, IV) or third dose (median, 50 mg/kg; range, 25–50 mg/kg, IV) was administered. Tranexamic acid induced emesis in 116 of 137 (84.7%) dogs. Median time to onset of emesis was 116.5 sec (range, 26–370 sec), median duration of emesis was 151.5 sec (range, 30–780 sec), and median number of emesis episodes was 2 (range, 1–8). Second and third administrations of tranexamic acid induced emesis in 64.7 and 66.7% of dogs, respectively. In total, IV administration of tranexamic acid successfully induced emesis in 129 of 137 (94.2%) dogs. Adverse effects included a tonic-clonic convulsion and hemostatic disorder in two different dogs, both of which recovered after receiving medical care. Tranexamic acid induced emesis in most dogs following a single-dose. When a single dose was not sufficient, an additional dosage effectively induced emesis. Overall, adverse effects were considered low and self-limiting. PMID:29093310

  11. Dose Response for Chromosome Aberrations in Human Lymphocytes and Fibroblasts after Exposure to Very Low Doses of High LET Radiation

    NASA Technical Reports Server (NTRS)

    Hada, M.; George, Kerry; Cucinotta, Francis A.

    2011-01-01

    The relationship between biological effects and low doses of absorbed radiation is still uncertain, especially for high LET radiation exposure. Estimates of risks from low-dose and low-dose-rates are often extrapolated using data from Japanese atomic bomb survivors with either linear or linear quadratic models of fit. In this study, chromosome aberrations were measured in human peripheral blood lymphocytes and normal skin fibroblasts cells after exposure to very low dose (1-20 cGy) of 170 MeV/u Si-28- ions or 600 MeV/u Fe-56-ions. Chromosomes were analyzed using the whole chromosome fluorescence in situ hybridization (FISH) technique during the first cell division after irradiation, and chromosome aberrations were identified as either simple exchanges (translocations and dicentrics) or complex exchanges (involving greater than 2 breaks in 2 or more chromosomes). The curves for doses above 10 cGy were fitted with linear or linear-quadratic functions. For Si-28- ions no dose response was observed in the 2-10 cGy dose range, suggesting a non-target effect in this range.

  12. Dose-response relationship in the treatment of gastrointestinal disorders.

    PubMed

    Weihrauch, T R; Demol, P

    1989-08-01

    Numerous clinical studies have been performed to establish efficacy and safety of drugs in gastroenterological disorders. Only in a few if any of these studies, however, the rationale for the optimal dose and the dose regimens, respectively, have been addressed. Adequate and well-controlled dose finding studies play a key role in the clinical assessment of new drugs and in the evaluation of new indications. Hereby the range from the minimal effective dose to the maximal effective and well tolerated dose can be assessed and thus the optimal dose-range and dosage regimen be determined. Meaningful pharmacodynamic studies can be performed in the gastrointestinal tract also in healthy volunteers provided that a method with a high predictability for the desired therapeutic effect is available such as measurement of gastric acid secretion and its inhibition by a drug. Dose finding studies in gastroenterology can be carried out under two main aspects: First, to assess the pharmacodynamic and therapeutic effect of a compound on the gastrointestinal tract (e.g. anti-ulcer drug). Second, to evaluate the side effects of a drug on the gastrointestinal tract (e.g. gastric mucosal damage by non-steroidal anti-inflammatory drugs). For the evaluation of new drugs in gastrointestinal therapy a number of methods are available which yield accurate and reproducible data. While careful clinical-pharmacological dose-response studies using these methods have been carried out already more than a decade ago, it is surprising that therapeutic dose finding studies have become available only during the past few years. For scientific as well as for ethical reasons more trials which determine the optimal therapeutic dose are warranted.

  13. Dosimetry in differentiated thyroid carcinoma (12-1402R)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Minguez, Pablo; Genolla, Jose; Celeiro, Jose Javier

    2013-01-15

    Purpose: The aim of this study has been to perform a dosimetric study in the treatments of differentiated thyroid cancer (DTC) performed in our center in order to find a dose-effect correlation. Methods: Thirty patients treated for DTC with 3700 MBq of {sup 131}I have been included in this study. For reasons of radiological protection all of them spent two nights as inpatients. Dose rate at 1 m from all patients was measured approximately 20 and 44 h after the administration of the radioiodine and a whole body scan in the gamma camera was performed approximately 1 week later. Withmore » those measurements and by using a model of two compartments the activities in thyroid bed remnants and in the whole body were calculated as a function of time. The integration of both activities yields the corresponding cumulated activities. Absorbed doses to thyroid bed remnants and to the whole body can be calculated following the MIRDOSE method-that is, by multiplying the corresponding cumulated activities by the corresponding S factors. Results: The absorbed doses to thyroid bed remnants calculated in this study fall into a very wide range (13-1161 Gy) and showed the highest correlation factors with the following parameters: the absorbed dose rate to thyroid bed remnants, the cumulated activity in thyroid bed remnants, and the maximum radioiodine uptake in thyroid bed remnants. The absorbed doses to the whole body range from 0.12 to 0.23 Gy. The ablation was successful in all patients, and in spite of the wide range of absorbed doses to thyroid bed remnants obtained, no dose-effect correlation could be obtained. Conclusions: Facing DTC treatments from a dosimetric viewpoint in which a predosimetry to calculate the activity of {sup 131}I to be administered is performed is a subject difficult to handle. This statement is based on the fact that although a very wide range of absorbed doses to thyroid bed remnants was obtained (including several absorbed doses well below some dose thresholds previously published to achieve ablation of thyroid bed remnants), ablation of thyroid bed remnants was successful for all patients and therefore no dose-effect correlation could be determined.« less

  14. Pharmacokinetics, Dose Proportionality, and Bioavailability of Bazedoxifene in Healthy Postmenopausal Women.

    PubMed

    McKeand, William

    2017-09-01

    Bazedoxifene is a selective estrogen receptor modulator that has estrogen agonist effects on bone and lipid metabolism while having neutral or estrogen antagonist effects on the breast and endometrium. The present report describes findings from 3 Phase I clinical studies that evaluated the single-dose pharmacokinetics (study 1; n = 84), multiple-dose pharmacokinetics (study 2; n = 23), and absolute bioavailability (study 3; n = 18) of bazedoxifene. All 3 studies enrolled healthy postmenopausal women who were either naturally postmenopausal or had undergone bilateral oophorectomy at least 6 months before the start of the study. Study 1 showed that unconjugated and total (unconjugated and conjugated) bazedoxifene levels increased proportionally with ascending oral doses of bazedoxifene (through the dose range of 5-120 mg). Evaluation with or without food intake was conducted at the 10-mg dose, with no clinically relevant effect on pharmacokinetic parameters. Study 2 showed that bazedoxifene achieved steady state in 1 week and exhibited linear pharmacokinetics in doses of 5 to 40 mg with no unexpected accumulation over the dose range. In accordance with a linear pharmacokinetic profile, mean maximum plasma concentration values increased with increasing dose, with values of 1.6, 6.2, and 12.5 ng/mL for the 5-, 20-, and 40-mg doses, respectively. In study 3, tablet and capsule formulations of bazedoxifene formulations had an estimated oral bioavailability of ~6%. The clearance of bazedoxifene was 0.4 (0.1) L/h/kg based on intravenous administration. The oral formulations had comparable exposure profiles with respect to AUC and AUC0-t, and the 90% CIs for these values were within the bioequivalence limits of 80% to 125%. Bazedoxifene was safe and well tolerated in all 3 studies. These pharmacokinetic evaluations in healthy postmenopausal women found that bazedoxifene displayed linear pharmacokinetics with doses ranging from 5 to 40 mg, with no unexpected accumulation. Food did not seem to have any clinically relevant impact on pharmacokinetic parameters. Bazedoxifene had an estimated oral bioavailability of ~6% and was safe and well tolerated in the range of doses evaluated. Copyright © 2017 Elsevier HS Journals, Inc. All rights reserved.

  15. Point-of-use chlorination of turbid water: results from a field study in Tanzania.

    PubMed

    Mohamed, Hussein; Brown, Joe; Njee, Robert M; Clasen, Thomas; Malebo, Hamisi M; Mbuligwe, Steven

    2015-06-01

    Household-based chlorine disinfection is widely effective against waterborne bacteria and viruses, and may be among the most inexpensive and accessible options for household water treatment. The microbiological effectiveness of chlorine is limited, however, by turbidity. In Tanzania, there are no guidelines on water chlorination at household level, and limited data on whether dosing guidelines for higher turbidity waters are sufficient to produce potable water. This study was designed to assess the effectiveness of chlorination across a range of turbidities found in rural water sources, following local dosing guidelines that recommend a 'double dose' for water that is visibly turbid. We chlorinated water from 43 sources representing a range of turbidities using two locally available chlorine-based disinfectants: WaterGuard and Aquatabs. We determined free available chlorine at 30 min and 24 h contact time. Our data suggest that water chlorination with WaterGuard or Aquatabs can be effective using both single and double doses up to 20 nephelometric turbidity units (NTU), or using a double dose of Aquatabs up to 100 NTU, but neither was effective at turbidities greater than 100 NTU.

  16. Evaluation of the dependence of the exposure dose on the attenuation correction in brain PET/CT scans using 18F-FDG

    NASA Astrophysics Data System (ADS)

    Choi, Eun-Jin; Jeong, Moon-Taeg; Jang, Seong-Joo; Choi, Nam-Gil; Han, Jae-Bok; Yang, Nam-Hee; Dong, Kyung-Rae; Chung, Woon-Kwan; Lee, Yun-Jong; Ryu, Young-Hwan; Choi, Sung-Hyun; Seong, Kyeong-Jeong

    2014-01-01

    This study examined whether scanning could be performed with minimum dose and minimum exposure to the patient after an attenuation correction. A Hoffman 3D Brain Phantom was used in BIO_40 and D_690 PET/CT scanners, and the CT dose for the equipment was classified as a low dose (minimum dose), medium dose (general dose for scanning) and high dose (dose with use of contrast medium) before obtaining the image at a fixed kilo-voltage-peak (kVp) and milliampere (mA) that were adjusted gradually in 17-20 stages. A PET image was then obtained to perform an attenuation correction based on an attenuation map before analyzing the dose difference. Depending on tube current in the range of 33-190 milliampere-second (mAs) when BIO_40 was used, a significant difference in the effective dose was observed between the minimum and the maximum mAs (p < 0.05). According to a Scheffe post-hoc test, the ratio of the minimum to the maximum of the effective dose was increased by approximately 5.26-fold. Depending on the change in the tube current in the range of 10-200 mA when D_690 was used, a significant difference in the effective dose was observed between the minimum and the maximum of mA (p < 0.05). The Scheffe posthoc test revealed a 20.5-fold difference. In conclusion, because effective exposure dose increases with increasing operating current, it is possible to reduce the exposure limit in a brain scan can be reduced if the CT dose can be minimized for a transmission scan.

  17. Radon exposure assessment for underground workers: a case of Seoul Subway Police officers in Korea.

    PubMed

    Song, Myeong Han; Chang, Byung-Uck; Kim, Yongjae; Cho, Kun-Woo

    2011-11-01

    The objective of this study is the systematic and individual assessment of the annual effective dose due to inhaled radon for the Seoul Subway Police officers, Korea. The annual average radon concentrations were found to be in the range of 18.9-114 Bq·m(-3) in their workplaces. The total annual effective doses which may likely to be received on duty were assessed to be in the range of 0.41-1.64 mSv·y(-1). These were well below the recommended action level 10 mSv·y(-1) by ICRP. However, the effective doses were higher than subway station staff in Seoul, Korea.

  18. Public health impact and cost-effectiveness of the RTS,S/AS01 malaria vaccine: a systematic comparison of predictions from four mathematical models.

    PubMed

    Penny, Melissa A; Verity, Robert; Bever, Caitlin A; Sauboin, Christophe; Galactionova, Katya; Flasche, Stefan; White, Michael T; Wenger, Edward A; Van de Velde, Nicolas; Pemberton-Ross, Peter; Griffin, Jamie T; Smith, Thomas A; Eckhoff, Philip A; Muhib, Farzana; Jit, Mark; Ghani, Azra C

    2016-01-23

    The phase 3 trial of the RTS,S/AS01 malaria vaccine candidate showed modest efficacy of the vaccine against Plasmodium falciparum malaria, but was not powered to assess mortality endpoints. Impact projections and cost-effectiveness estimates for longer timeframes than the trial follow-up and across a range of settings are needed to inform policy recommendations. We aimed to assess the public health impact and cost-effectiveness of routine use of the RTS,S/AS01 vaccine in African settings. We compared four malaria transmission models and their predictions to assess vaccine cost-effectiveness and impact. We used trial data for follow-up of 32 months or longer to parameterise vaccine protection in the group aged 5-17 months. Estimates of cases, deaths, and disability-adjusted life-years (DALYs) averted were calculated over a 15 year time horizon for a range of levels of Plasmodium falciparum parasite prevalence in 2-10 year olds (PfPR2-10; range 3-65%). We considered two vaccine schedules: three doses at ages 6, 7·5, and 9 months (three-dose schedule, 90% coverage) and including a fourth dose at age 27 months (four-dose schedule, 72% coverage). We estimated cost-effectiveness in the presence of existing malaria interventions for vaccine prices of US$2-10 per dose. In regions with a PfPR2-10 of 10-65%, RTS,S/AS01 is predicted to avert a median of 93,940 (range 20,490-126,540) clinical cases and 394 (127-708) deaths for the three-dose schedule, or 116,480 (31,450-160,410) clinical cases and 484 (189-859) deaths for the four-dose schedule, per 100,000 fully vaccinated children. A positive impact is also predicted at a PfPR2-10 of 5-10%, but there is little impact at a prevalence of lower than 3%. At $5 per dose and a PfPR2-10 of 10-65%, we estimated a median incremental cost-effectiveness ratio compared with current interventions of $30 (range 18-211) per clinical case averted and $80 (44-279) per DALY averted for the three-dose schedule, and of $25 (16-222) and $87 (48-244), respectively, for the four-dose schedule. Higher ICERs were estimated at low PfPR2-10 levels. We predict a significant public health impact and high cost-effectiveness of the RTS,S/AS01 vaccine across a wide range of settings. Decisions about implementation will need to consider levels of malaria burden, the cost-effectiveness and coverage of other malaria interventions, health priorities, financing, and the capacity of the health system to deliver the vaccine. PATH Malaria Vaccine Initiative; Bill & Melinda Gates Foundation; Global Good Fund; Medical Research Council; UK Department for International Development; GAVI, the Vaccine Alliance; WHO. Copyright © 2016 Penny et al. Open Access article distributed under the terms of CC BY. Published by Elsevier Ltd.. All rights reserved.

  19. Public health impact and cost-effectiveness of the RTS,S/AS01 malaria vaccine: a systematic comparison of predictions from four mathematical models

    PubMed Central

    Penny, Melissa A; Verity, Robert; Bever, Caitlin A; Sauboin, Christophe; Galactionova, Katya; Flasche, Stefan; White, Michael T; Wenger, Edward A; Van de Velde, Nicolas; Pemberton-Ross, Peter; Griffin, Jamie T; Smith, Thomas A; Eckhoff, Philip A; Muhib, Farzana; Jit, Mark; Ghani, Azra C

    2016-01-01

    Summary Background The phase 3 trial of the RTS,S/AS01 malaria vaccine candidate showed modest efficacy of the vaccine against Plasmodium falciparum malaria, but was not powered to assess mortality endpoints. Impact projections and cost-effectiveness estimates for longer timeframes than the trial follow-up and across a range of settings are needed to inform policy recommendations. We aimed to assess the public health impact and cost-effectiveness of routine use of the RTS,S/AS01 vaccine in African settings. Methods We compared four malaria transmission models and their predictions to assess vaccine cost-effectiveness and impact. We used trial data for follow-up of 32 months or longer to parameterise vaccine protection in the group aged 5–17 months. Estimates of cases, deaths, and disability-adjusted life-years (DALYs) averted were calculated over a 15 year time horizon for a range of levels of Plasmodium falciparum parasite prevalence in 2–10 year olds (PfPR2–10; range 3–65%). We considered two vaccine schedules: three doses at ages 6, 7·5, and 9 months (three-dose schedule, 90% coverage) and including a fourth dose at age 27 months (four-dose schedule, 72% coverage). We estimated cost-effectiveness in the presence of existing malaria interventions for vaccine prices of US$2–10 per dose. Findings In regions with a PfPR2–10 of 10–65%, RTS,S/AS01 is predicted to avert a median of 93 940 (range 20 490–126 540) clinical cases and 394 (127–708) deaths for the three-dose schedule, or 116 480 (31 450–160 410) clinical cases and 484 (189–859) deaths for the four-dose schedule, per 100 000 fully vaccinated children. A positive impact is also predicted at a PfPR2–10 of 5–10%, but there is little impact at a prevalence of lower than 3%. At $5 per dose and a PfPR2–10 of 10–65%, we estimated a median incremental cost-effectiveness ratio compared with current interventions of $30 (range 18–211) per clinical case averted and $80 (44–279) per DALY averted for the three-dose schedule, and of $25 (16–222) and $87 (48–244), respectively, for the four-dose schedule. Higher ICERs were estimated at low PfPR2–10 levels. Interpretation We predict a significant public health impact and high cost-effectiveness of the RTS,S/AS01 vaccine across a wide range of settings. Decisions about implementation will need to consider levels of malaria burden, the cost-effectiveness and coverage of other malaria interventions, health priorities, financing, and the capacity of the health system to deliver the vaccine. Funding PATH Malaria Vaccine Initiative; Bill & Melinda Gates Foundation; Global Good Fund; Medical Research Council; UK Department for International Development; GAVI, the Vaccine Alliance; WHO. PMID:26549466

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sugano, Yasutaka; Mizuta, Masahiro; Takao, Seishin

    Purpose: Radiotherapy of solid tumors has been performed with various fractionation regimens such as multi- and hypofractionations. However, the ability to optimize the fractionation regimen considering the physical dose distribution remains insufficient. This study aims to optimize the fractionation regimen, in which the authors propose a graphical method for selecting the optimal number of fractions (n) and dose per fraction (d) based on dose–volume histograms for tumor and normal tissues of organs around the tumor. Methods: Modified linear-quadratic models were employed to estimate the radiation effects on the tumor and an organ at risk (OAR), where the repopulation of themore » tumor cells and the linearity of the dose-response curve in the high dose range of the surviving fraction were considered. The minimization problem for the damage effect on the OAR was solved under the constraint that the radiation effect on the tumor is fixed by a graphical method. Here, the damage effect on the OAR was estimated based on the dose–volume histogram. Results: It was found that the optimization of fractionation scheme incorporating the dose–volume histogram is possible by employing appropriate cell surviving models. The graphical method considering the repopulation of tumor cells and a rectilinear response in the high dose range enables them to derive the optimal number of fractions and dose per fraction. For example, in the treatment of prostate cancer, the optimal fractionation was suggested to lie in the range of 8–32 fractions with a daily dose of 2.2–6.3 Gy. Conclusions: It is possible to optimize the number of fractions and dose per fraction based on the physical dose distribution (i.e., dose–volume histogram) by the graphical method considering the effects on tumor and OARs around the tumor. This method may stipulate a new guideline to optimize the fractionation regimen for physics-guided fractionation.« less

  1. Individual external doses below the lowest reference level of 1 mSv per year five years after the 2011 Fukushima nuclear accident among all children in Soma City, Fukushima: A retrospective observational study.

    PubMed

    Tsubokura, Masaharu; Murakami, Michio; Nomura, Shuhei; Morita, Tomohiro; Nishikawa, Yoshitaka; Leppold, Claire; Kato, Shigeaki; Kami, Masahiro

    2017-01-01

    After the 2011 Fukushima Daiichi nuclear power plant accident, little information has been available on individual doses from external exposure among residents living in radioactively contaminated areas near the nuclear plant; in the present study we evaluated yearly changes in the doses from external exposure after the accident and the effects of decontamination on external exposure. This study considered all children less than 16 years of age in Soma City, Fukushima who participated in annual voluntary external exposure screening programs during the five years after the accident (n = 5,363). In total, 14,405 screening results were collected. The median participant age was eight years. The geometric mean levels of annual additional doses from external exposure attributable to the Fukushima accident, decreased each year: 0.60 mSv (range: not detectable (ND)-4.29 mSv), 0.37 mSv (range: ND-3.61 mSv), 0.22 mSv (range: ND-1.44 mSv), 0.20 mSv (range: ND-1.87 mSv), and 0.17 mSv (range: ND-0.85 mSv) in 2011, 2012, 2013, 2014, and 2015, respectively. The proportion of residents with annual additional doses from external exposure of more than 1 mSv dropped from 15.6% in 2011 to zero in 2015. Doses from external exposure decreased more rapidly than those estimated from only physical decay, even in areas without decontamination (which were halved in 395 days from November 15, 2011), presumably due to the weathering effects. While the ratios of geometric mean doses immediately after decontamination to before were slightly lower than those during the same time in areas without decontamination, annual additional doses reduced by decontamination were small (0.04-0.24 mSv in the year of immediately after decontamination was completed). The results of this study showed that the levels of external exposure among Soma residents less than 16 years of age decreased during the five years after the Fukushima Daiichi nuclear power plant accident. Decontamination had only limited and temporal effects on reducing individual external doses.

  2. Threshold-type dose response for induction of neoplastic transformation by 1 GeV/nucleon iron ions.

    PubMed

    Elmore, E; Lao, X-Y; Kapadia, R; Redpath, J L

    2009-06-01

    Neoplastic transformation of HeLa x skin fibroblast human hybrid cells by doses of 1 GeV/nucleon iron ions in the range 1 cGy to 1 Gy to exposed cultures has been examined. The data indicate a threshold-type dose-response curve with no increase in transformation frequency until doses above 20 cGy. At doses <10 cGy, not all exposed cells receive a direct traversal of an iron-ion track core, but all exposed cells receive up to several mGy of low-LET radiation associated with the delta-ray penumbra. It is proposed that the threshold-type response seen is a consequence of an adaptive response associated with the delta-ray exposure. For comparison purposes, the dose response for (137)Cs gamma rays over the same dose range was examined using the same experimental procedure. As we have shown previously, the dose response for (137)Cs gamma radiation was J-shaped. The iron ions were 1.5 to 1.7 times more biologically effective than the gamma radiation over the dose range examined.

  3. Long-Term Dose-Dependent Agalsidase Effects on Kidney Histology in Fabry Disease.

    PubMed

    Skrunes, Rannveig; Tøndel, Camilla; Leh, Sabine; Larsen, Kristin Kampevold; Houge, Gunnar; Davidsen, Einar Skulstad; Hollak, Carla; van Kuilenburg, André B P; Vaz, Frédéric M; Svarstad, Einar

    2017-09-07

    Dose-dependent clearing of podocyte globotriaosylceramide has previously been shown in patients with classic Fabry disease treated with enzyme replacement. Our study evaluates the dose-dependent effects of agalsidase therapy in serial kidney biopsies of patients treated for up to 14 years. Twenty patients with classic Fabry disease (12 men) started enzyme replacement therapy at a median age of 21 (range =7-62) years old. Agalsidase- α or - β was prescribed for a median of 9.4 (range =5-14) years. The lower fixed dose group received agalsidase 0.2 mg/kg every other week throughout the follow-up period. The higher dose group received a range of agalsidase doses (0.2-1.0 mg/kg every other week). Dose changes were made due to disease progression, suboptimal effect, or agalsidase- β shortage. Serial kidney biopsies were performed along with clinical assessment and biomarkers and scored according to recommendations from the International Study Group of Fabry Nephropathy. No statistical differences were found in baseline or final GFR or albuminuria. Kidney biopsies showed significant reduction of podocyte globotriaosylceramide in both the lower fixed dose group (-1.39 [SD=1.04]; P =0.004) and the higher dose group (-3.16 [SD=2.39]; P =0.002). Podocyte globotriaosylceramide (Gb3) reduction correlated with cumulative agalsidase dose ( r =0.69; P =0.001). Arterial/arteriolar intima Gb3 cleared significantly in the higher dose group, all seven patients with baseline intimal Gb3 cleared the intima, one patient gained intimal Gb3 inclusions ( P =0.03), and medial Gb3 did not change statistically in either group. Residual plasma globotriaosylsphingosine levels remained higher in the lower fixed dose group (20.1 nmol/L [SD=11.9]) compared with the higher dose group (10.4 nmol/L [SD=8.4]) and correlated with cumulative agalsidase dose in men ( r =0.71; P =0.01). Reduction of podocyte globotriaosylceramide was found in patients with classic Fabry disease treated with long-term agalsidase on different dosing regimens, correlating with cumulative dose. Limited clearing of arterial/arteriolar globotriaosylceramide raises concerns regarding long-term vascular effects of current therapy. Residual plasma globotriaosylsphingosine correlated with cumulative dose in men. Copyright © 2017 by the American Society of Nephrology.

  4. Quantifying the effect of air gap, depth, and range shifter thickness on TPS dosimetric accuracy in superficial PBS proton therapy.

    PubMed

    Shirey, Robert J; Wu, Hsinshun Terry

    2018-01-01

    This study quantifies the dosimetric accuracy of a commercial treatment planning system as functions of treatment depth, air gap, and range shifter thickness for superficial pencil beam scanning proton therapy treatments. The RayStation 6 pencil beam and Monte Carlo dose engines were each used to calculate the dose distributions for a single treatment plan with varying range shifter air gaps. Central axis dose values extracted from each of the calculated plans were compared to dose values measured with a calibrated PTW Markus chamber at various depths in RW3 solid water. Dose was measured at 12 depths, ranging from the surface to 5 cm, for each of the 18 different air gaps, which ranged from 0.5 to 28 cm. TPS dosimetric accuracy, defined as the ratio of calculated dose relative to the measured dose, was plotted as functions of depth and air gap for the pencil beam and Monte Carlo dose algorithms. The accuracy of the TPS pencil beam dose algorithm was found to be clinically unacceptable at depths shallower than 3 cm with air gaps wider than 10 cm, and increased range shifter thickness only added to the dosimetric inaccuracy of the pencil beam algorithm. Each configuration calculated with Monte Carlo was determined to be clinically acceptable. Further comparisons of the Monte Carlo dose algorithm to the measured spread-out Bragg Peaks of multiple fields used during machine commissioning verified the dosimetric accuracy of Monte Carlo in a variety of beam energies and field sizes. Discrepancies between measured and TPS calculated dose values can mainly be attributed to the ability (or lack thereof) of the TPS pencil beam dose algorithm to properly model secondary proton scatter generated in the range shifter. © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  5. An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada

    PubMed Central

    Deeks, Shelley L.; Lim, Gillian H.; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S.

    2011-01-01

    Background This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Methods Information on confirmed cases of mumps was retrieved from Ontario’s integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R0) represents the average number of new infections per case in a fully susceptile population, and R0 values of between 4 and 10 were considered for varying levels of vaccine effectiveness. Results A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Interpretation Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs. PMID:21576295

  6. An assessment of mumps vaccine effectiveness by dose during an outbreak in Canada.

    PubMed

    Deeks, Shelley L; Lim, Gillian H; Simpson, Mary Anne; Gagné, Louise; Gubbay, Jonathan; Kristjanson, Erik; Fung, Cecilia; Crowcroft, Natasha S

    2011-06-14

    This investigation was done to assess vaccine effectiveness of one and two doses of the measles, mumps and rubella (MMR) vaccine during an outbreak of mumps in Ontario. The level of coverage required to reach herd immunity and interrupt community transmission of mumps was also estimated. Information on confirmed cases of mumps was retrieved from Ontario's integrated Public Health Information System. Cases that occurred between Sept. 1, 2009, and June 10, 2010, were included. Selected health units supplied coverage data from the Ontario Immunization Record Information System. Vaccine effectiveness by dose was calculated using the screening method. The basic reproductive number (R(0)) represents the average number of new infections per case in a fully susceptible population, and R(0) values of between 4 and 10 were considered for varying levels of vaccine effectiveness. A total of 134 confirmed cases of mumps were identified. Information on receipt of MMR vaccine was available for 114 (85.1%) cases, of whom 63 (55.3%) reported having received only one dose of vaccine; 32 (28.1%) reported having received two doses. Vaccine effectiveness of one dose of the MMR vaccine ranged from 49.2% to 81.6%, whereas vaccine effectiveness of two doses ranged from 66.3% to 88.0%. If we assume vaccine effectiveness of 85% for two doses of the vaccine, vaccine coverage of 88.2% and 98.0% would be needed to interrupt community transmission of mumps if the corresponding reproductive values were four and six. Our estimates of vaccine effectiveness of one and two doses of mumps-containing vaccine were consistent with the estimates that have been reported in other outbreaks. Outbreaks occurring in Ontario and elsewhere serve as a warning against complacency over vaccination programs.

  7. Estimating the effective radiation dose imparted to patients by intraoperative cone-beam computed tomography in thoracolumbar spinal surgery.

    PubMed

    Lange, Jeffrey; Karellas, Andrew; Street, John; Eck, Jason C; Lapinsky, Anthony; Connolly, Patrick J; Dipaola, Christian P

    2013-03-01

    Observational. To estimate the radiation dose imparted to patients during typical thoracolumbar spinal surgical scenarios. Minimally invasive techniques continue to become more common in spine surgery. Computer-assisted navigation systems coupled with intraoperative cone-beam computed tomography (CT) represent one such method used to aid in instrumented spinal procedures. Some studies indicate that cone-beam CT technology delivers a relatively low dose of radiation to patients compared with other x-ray-based imaging modalities. The goal of this study was to estimate the radiation exposure to the patient imparted during typical posterior thoracolumbar instrumented spinal procedures, using intraoperative cone-beam CT and to place these values in the context of standard CT doses. Cone-beam CT scans were obtained using Medtronic O-arm (Medtronic, Minneapolis, MN). Thermoluminescence dosimeters were placed in a linear array on a foam-plastic thoracolumbar spine model centered above the radiation source for O-arm presets of lumbar scans for small or large patients. In-air dosimeter measurements were converted to skin surface measurements, using published conversion factors. Dose-length product was calculated from these values. Effective dose was estimated using published effective dose to dose-length product conversion factors. Calculated dosages for many full-length procedures using the small-patient setting fell within the range of published effective doses of abdominal CT scans (1-31 mSv). Calculated dosages for many full-length procedures using the large-patient setting fell within the range of published effective doses of abdominal CT scans when the number of scans did not exceed 3. We have demonstrated that single cone-beam CT scans and most full-length posterior instrumented spinal procedures using O-arm in standard mode would likely impart a radiation dose within the range of those imparted by a single standard CT scan of the abdomen. Radiation dose increases with patient size, and the radiation dose received by larger patients as a result of more than 3 O-arm scans in standard mode may exceed the dose received during standard CT of the abdomen. Understanding radiation imparted to patients by cone-beam CT is important for assessing risks and benefits of this technology, especially when spinal surgical procedures require multiple intraoperative scans.

  8. Risk Factors and Dose-Effect Relationship for Mandibular Osteoradionecrosis in Oral and Oropharyngeal Cancer Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Ik Jae; Koom, Woong Sub; Lee, Chang Geol, E-mail: cglee1023@yuhs.a

    2009-11-15

    Purpose: To analyze risk factors and the dose-effect relationship for osteoradionecrosis (ORN) of the mandible after radiotherapy of oral and oropharyngeal cancers. Materials and Methods: One-hundred ninety-eight patients with oral (45%) and oropharyngeal cancer (55%) who had received external radiotherapy between 1990 and 2000 were retrospectively reviewed. All patients had a dental evaluation before radiotherapy. The median radiation dose was 60 Gy (range, 16-75 Gy), and the median biologically effective dose for late effects (BED{sub late}) in bone was 114 Gy{sub 2} (range, 30-167 Gy{sub 2}). Results: The frequency of ORN was 13 patients (6.6%). Among patients with mandibular surgery,more » eight had ORN at the surgical site. Among patients without mandibular surgery, five patients had ORN on the molar area of the mandible. The median time to ORN was 22 months (range, 1-69 months). Univariate analysis revealed that mandibular surgery and Co-60 were significant risk factors for ORN (p = 0.01 and 0.04, respectively). In multivariate analysis, mandibular surgery was the most important factor (p = 0.001). High radiation doses over BED 102.6 Gy{sub 2} (conventional dose of 54 Gy at 1.8 Gy/fraction) were also a significant factor for ORN (p = 0.008) and showed a positive dose-effect relationship in logistic regression (p = 0.04) for patients who had undergone mandibular surgery. Conclusions: Mandibular surgery was the most significant risk factor for ORN of mandible in oral and oropharyngeal cancers patients. A BED of 102.6 Gy{sub 2} or higher to the mandible also significantly increases the risk of ORN.« less

  9. High doses of bone morphogenetic protein 2 induce structurally abnormal bone and inflammation in vivo.

    PubMed

    Zara, Janette N; Siu, Ronald K; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M; Ting, Kang; Soo, Chia

    2011-05-01

    The major Food and Drug Association-approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL.

  10. High Doses of Bone Morphogenetic Protein 2 Induce Structurally Abnormal Bone and Inflammation In Vivo

    PubMed Central

    Zara, Janette N.; Siu, Ronald K.; Zhang, Xinli; Shen, Jia; Ngo, Richard; Lee, Min; Li, Weiming; Chiang, Michael; Chung, Jonguk; Kwak, Jinny; Wu, Benjamin M.; Ting, Kang

    2011-01-01

    The major Food and Drug Association–approved osteoinductive factors in wide clinical use are bone morphogenetic proteins (BMPs). Although BMPs can promote robust bone formation, they also induce adverse clinical effects, including cyst-like bone formation and significant soft tissue swelling. In this study, we evaluated multiple BMP2 doses in a rat femoral segmental defect model and in a minimally traumatic rat femoral onlay model to determine its dose-dependent effects. Results of our femoral segmental defect model established a low BMP2 concentration range (5 and 10 μg/mL, total dose 0.375 and 0.75 μg in 75 μg total volume) unable to induce defect fusion, a mid-range BMP2 concentration range able to fuse the defect without adverse effects (30 μg/mL, total dose 2.25 μg in 75 μg total volume), and a high BMP2 concentration range (150, 300, and 600 μg/mL, total dose 11.25, 22.5, and 45 μg in 75 μg total volume) able to fuse the defect, but with formation of cyst-like bony shells filled with histologically confirmed adipose tissue. In addition, compared to control, 4 mg/mL BMP2 also induced significant tissue inflammatory infiltrates and exudates in the femoral onlay model that was accompanied by increased numbers of osteoclast-like cells at 3, 7, and 14 days. Overall, we consistently reproduced BMP2 side effects of cyst-like bone and soft tissue swelling using high BMP2 concentration approaching the typical human 1500 μg/mL. PMID:21247344

  11. Single- and Repeat-dose Oral Toxicity Studies of Lithospermum erythrorhizon Extract in Dogs

    PubMed Central

    Hwang, Jae-Sik; Kim, Myoung-Jun; Choi, Young Whan; Han, Kyoung-Goo; Kang, Jong-Koo

    2015-01-01

    Lithospermum erythrorhizon has long been used in traditional Asian medicine for the treatment of diseases, including skin cancer. The oral toxicity of a hexane extract of Lithospermum erythrorhizon root (LEH) was investigated in Beagle dogs by using single escalating doses, two-week dose range-finding, and 4-week oral repeat dosing. In the single dose-escalating oral toxicity study, no animal died, showed adverse clinical signs, or changes in body weight gain at LEH doses of up to 2,000 mg/kg. In a 2 week dose range-finding study, no treatment-related adverse effects were detected by urinalysis, hematology, blood biochemistry, organ weights, or gross and histopathological examinations at doses of up to 500 mg LEH/kg/day. In the 4 week repeat-dose toxicity study, a weight loss or decreased weight gain was observed at 300 mg/kg/day. Although levels of serum triglyceride and total bilirubin were increased in a dose dependent manner, there were no related morphological changes. Based on these findings, the sub-acute no observable adverse effect level for 4-week oral administration of LEH in Beagles was 100 mg/kg/day. PMID:25874036

  12. Single- and Repeat-dose Oral Toxicity Studies of Lithospermum erythrorhizon Extract in Dogs.

    PubMed

    Nam, Chunja; Hwang, Jae-Sik; Kim, Myoung-Jun; Choi, Young Whan; Han, Kyoung-Goo; Kang, Jong-Koo

    2015-03-01

    Lithospermum erythrorhizon has long been used in traditional Asian medicine for the treatment of diseases, including skin cancer. The oral toxicity of a hexane extract of Lithospermum erythrorhizon root (LEH) was investigated in Beagle dogs by using single escalating doses, two-week dose range-finding, and 4-week oral repeat dosing. In the single dose-escalating oral toxicity study, no animal died, showed adverse clinical signs, or changes in body weight gain at LEH doses of up to 2,000 mg/kg. In a 2 week dose range-finding study, no treatment-related adverse effects were detected by urinalysis, hematology, blood biochemistry, organ weights, or gross and histopathological examinations at doses of up to 500 mg LEH/kg/day. In the 4 week repeat-dose toxicity study, a weight loss or decreased weight gain was observed at 300 mg/kg/day. Although levels of serum triglyceride and total bilirubin were increased in a dose dependent manner, there were no related morphological changes. Based on these findings, the sub-acute no observable adverse effect level for 4-week oral administration of LEH in Beagles was 100 mg/kg/day.

  13. Dosimetric characteristics of a MOSFET dosimeter for clinical electron beams.

    PubMed

    Manigandan, D; Bharanidharan, G; Aruna, P; Devan, K; Elangovan, D; Patil, Vikram; Tamilarasan, R; Vasanthan, S; Ganesan, S

    2009-09-01

    The fundamental dosimetric characteristics of commercially available metal oxide semiconductor field effect transistor (MOSFET) detectors were studied for clinical electron beam irradiations. MOSFET showed excellent linearity against doses measured using an ion chamber in the dose range of 20-630cGy. MOSFET reproducibility is better at high doses compared to low doses. The output factors measured with the MOSFET were within +/-3% when compared with those measured with a parallel plate chamber. From 4 to 12MeV, MOSFETs showed a large angular dependence in the tilt directions and less in the axial directions. MOSFETs do not show any dose-rate dependence between 100 and 600MU/min. However, MOSFETs have shown under-response when the dose per pulse of the beam is decreased. No measurable effect in MOSFET response was observed in the temperature range of 23-40 degrees C. The energy dependence of a MOSFET dosimeter was within +/-3.0% for 6-18MeV electron beams and 5.5% for 4MeV ones. This study shows that MOSFET detectors are suitable for dosimetry of electron beams in the energy range of 4-18MeV.

  14. Effect of γ-dose rate and total dose interrelation on the polymeric hydrogel: A novel injectable male contraceptive

    NASA Astrophysics Data System (ADS)

    Jha, Pradeep K.; Jha, Rakhi; Gupta, B. L.; Guha, Sujoy K.

    2010-05-01

    Functional necessity to use a particular range of dose rate and total dose of γ-initiated polymerization to manufacture a novel polymeric hydrogel RISUG ® (reversible inhibition of sperm under guidance) made of styrene maleic anhydride (SMA) dissolved in dimethyl sulphoxide (DMSO), for its broad biomedical application explores new dimension of research. The present work involves 16 irradiated samples. They were tested by fourier transform infrared spectroscopy, matrix assisted laser desorption/ionization-TOF, field emission scanning electron microscopy, high resolution transmission electron microscopy, etc. to see the interrelation effect of gamma dose rates (8.25, 17.29, 20.01 and 25.00 Gy/min) and four sets of doses (1.8, 2.0, 2.2 and 2.4 kGy) on the molecular weight, molecular weight distribution and porosity analysis of the biopolymeric drug RISUG ®. The results of randomized experiment indicated that a range of 18-24 Gy/min γ-dose rate and 2.0-2.4 kGy γ-total doses is suitable for the desirable in vivo performance of the contraceptive copolymer.

  15. Effect of proton irradiation dose on InAlN/GaN metal-oxide semiconductor high electron mobility transistors with Al 2O 3 gate oxide

    DOE PAGES

    Ahn, Shihyun; Kim, Byung -Jae; Lin, Yi -Hsuan; ...

    2016-07-26

    The effects of proton irradiation on the dc performance of InAlN/GaN metal-oxide-semiconductor high electron mobility transistors (MOSHEMTs) with Al 2O 3 as the gate oxide were investigated. The InAlN/GaN MOSHEMTs were irradiated with doses ranging from 1×10 13 to 1×10 15cm –2 at a fixed energy of 5MeV. There was minimal damage induced in the two dimensional electron gas at the lowest irradiation dose with no measurable increase in sheet resistance, whereas a 9.7% increase of the sheet resistance was observed at the highest irradiation dose. By sharp contrast, all irradiation doses created more severe degradation in the Ohmic metalmore » contacts, with increases of specific contact resistance from 54% to 114% over the range of doses investigated. These resulted in source-drain current–voltage decreases ranging from 96 to 242 mA/mm over this dose range. The trap density determined from temperature dependent drain current subthreshold swing measurements increased from 1.6 × 10 13 cm –2 V –1 for the reference MOSHEMTs to 6.7 × 10 13 cm –2 V –1 for devices irradiated with the highest dose. In conclusion, the carrier removal rate was 1287 ± 64 cm –1, higher than the authors previously observed in AlGaN/GaN MOSHEMTs for the same proton energy and consistent with the lower average bond energy of the InAlN.« less

  16. A Radiobiological Analysis of Multicenter Data for Postoperative Keloid Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flickinger, John C., E-mail: flickingerjc@upmc.ed

    2011-03-15

    Purpose: To identify factors significantly affecting recurrence rates after postoperative external beam radiotherapy (XRT) of keloids, and to delineate any radiation dose response and effects of radiation dose per fraction. Methods and Materials: A comprehensive literature review was performed to compile a database of 2,515 resected keloids (36.9% earlobe). Postoperative XRT was 45- to 100-kV X-rays in 27.0% or 120- to 250-kV X-rays in 11.1%, Co-60 in 1.9%, Sr-90 in 4.7%, 1.5- to 9-MeV electrons in 26.5%, and no XRT in 28.8%. In the 1,791 irradiated patients, the median radiation parameters were as follows: total dose, 15 Gy (range, 6-30more » Gy); dose per fraction, 5.0 Gy (range, 2-15 Gy); fractions, 3 (range, 1-10); and time, 7 days (range, 0-33 days). Results: Multivariate stepwise logistic regression correlated decreased keloid recurrence with earlobe location (p = 1.98E-10; odds ratio, 0.34), biologically effective dose (p = 1.01E-27), and treatment with electron beam or Co-60 vs. other techniques (p = 0.0014; odds ratio, 0.72). Different radiobiological models calculated values of {alpha}/{beta} = 1.12 to 2.86 (mean, 2.08) and time (repopulation) correction factors for biologically effective dose from 0.98 to 2.13 Gy per day (mean, 1.34) starting 10 days after surgery. Different models (with {alpha}/{beta} = 2.08) predicted that doses needed for 90% and 95% control with 3 fractions of postoperative electron beam were 16.0 to 16.2 Gy and 18.3 to 19.2 Gy, respectively, in less than 10 days for earlobe keloids and 21.5 to 22.2 Gy and 23.4 to 24.8 Gy, respectively, in less than 10 days for other sites. Conclusions: Postoperative keloid radiotherapy requires moderately high doses and optimal technique to be effective. The relatively low {alpha}/{beta} ratio indicates that radiotherapy with a limited number of fractions and high doses per fraction is the best strategy.« less

  17. Genetic effects on heavy ions in drosophila

    NASA Technical Reports Server (NTRS)

    Kale, P. G.

    1986-01-01

    Drosophila sex-linked recessive lethal mutation test was used to study the dose response relation and relative biological effectiveness of heavy ions. The experiments were performed using the heavy ion beams at BEVALAC of Lawrence Berkeley Laboratory. These experiments were undertaken according to the proposed milestones and included Ne-20, A-40 and Fe-65 ions with respective energies of 600 MeV, 840 MeV and 850 MeV. At these energies several doses of these radiations ranging from 20 to 1280 R were used. Space radiation exposure to astronauts is supposed to be quite low and therefore very low dose experiments i.e., 20 R, were also performed for the three ions. The mutation response was measured in all germ cell types i.e., spermatozoa, spermatids, spermatocytes and spermatogonia of treated Drosophila males. A linear dose frequency relation was observed for most of the range except at high doses where the saturation effect was observed. Also, a very significant difference was observed among the sensitivity of the four germ cell stages where spermatozoa and spermatids were more sensitive. At the higher doses of this range, most of the spermatogonia and spermatocytes were killed. Although comparative and identical experiments with X-rays or neutrons have not been performed, the compassion of our data with the ones available in literature suggest that the heavy ions have a high rbe and that they are several times more effective than low LET X-rays. The rbe compared to neutrons however appears to be only slightly higher.

  18. Assessment of effective radiation dose of an extremity CBCT, MSCT and conventional X ray for knee area using MOSFET dosemeters.

    PubMed

    Koivisto, Juha; Kiljunen, Timo; Wolff, Jan; Kortesniemi, Mika

    2013-12-01

    The objective of this study was to assess and compare the organ and effective doses in the knee area resulting from different commercially available multislice computed tomography devices (MSCT), one cone beam computed tomography device (CBCT) and one conventional X-ray radiography device using MOSFET dosemeters and an anthropomorphic RANDO knee phantom. Measurements of the MSCT devices resulted in effective doses ranging between 27 and 48 µSv. The CBCT measurements resulted in an effective dose of 12.6 µSv. The effective doses attained using the conventional radiography device were 1.8 µSv for lateral and 1.2 µSv for anterior-posterior projections. The effective dose resulting from conventional radiography was considerably lower than those recorded for the CBCT and MSCT devices. The MSCT effective dose results were two to four times higher than those measured on the CBCT device. This study demonstrates that CBCT can be regarded as a potential low-dose 3D imaging technique for knee examinations.

  19. SU-F-T-185: Study of the Robustness of a Proton Arc Technique Based On PBS Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Z; Zheng, Y

    Purpose: One potential technique to realize proton arc is through using PBS beams from many directions to form overlaid Bragg peak (OBP) spots and placing these OBP spots throughout the target volume to achieve desired dose distribution. In this study, we analyzed the robustness of this proton arc technique. Methods: We used a cylindrical water phantom of 20 cm in radius in our robustness analysis. To study the range uncertainty effect, we changed the density of the phantom by ±3%. To study the setup uncertainty effect, we shifted the phantom by 3 & 5 mm. We also combined the rangemore » and setup uncertainties (3mm/±3%). For each test plan, we performed dose calculation for the nominal and 6 disturbed scenarios. Two test plans were used, one with single OBP spot and the other consisting of 121 OBP spots covering a 10×10cm{sup 2} area. We compared the dose profiles between the nominal and disturbed scenarios to estimate the impact of the uncertainties. Dose calculation was performed with Gate/GEANT based Monte Carlo software in cloud computing environment. Results: For each of the 7 scenarios, we simulated 100k & 10M events for plans consisting of single OBP spot and 121 OBP spots respectively. For single OBP spot, the setup uncertainty had minimum impact on the spot’s dose profile while range uncertainty had significant impact on the dose profile. For plan consisting of 121 OBP spots, similar effect was observed but the extent of disturbance was much less compared to single OBP spot. Conclusion: For PBS arc technique, range uncertainty has significantly more impact than setup uncertainty. Although single OBP spot can be severely disturbed by the range uncertainty, the overall effect is much less when a large number of OBP spots are used. Robustness optimization for PBS arc technique should consider range uncertainty with priority.« less

  20. Neutron organ dose and the influence of adipose tissue

    NASA Astrophysics Data System (ADS)

    Simpkins, Robert Wayne

    Neutron fluence to dose conversion coefficients have been assessed considering the influences of human adipose tissue. Monte Carlo code MCNP4C was used to simulate broad parallel beam monoenergetic neutrons ranging in energy from thermal to 10 MeV. Simulated Irradiations were conducted for standard irradiation geometries. The targets were on gender specific mathematical anthropomorphic phantoms modified to approximate human adipose tissue distributions. Dosimetric analysis compared adipose tissue influence against reference anthropomorphic phantom characteristics. Adipose Male and Post-Menopausal Female Phantoms were derived introducing interstitial adipose tissue to account for 22 and 27 kg additional body mass, respectively, each demonstrating a Body Mass Index (BMI) of 30. An Adipose Female Phantom was derived introducing specific subcutaneous adipose tissue accounting for 15 kg of additional body mass demonstrating a BMI of 26. Neutron dose was shielded in the superficial tissues; giving rise to secondary photons which dominated the effective dose for Incident energies less than 100 keV. Adipose tissue impact on the effective dose was a 25% reduction at the anterior-posterior incidence ranging to a 10% increase at the lateral incidences. Organ dose impacts were more distinctive; symmetrically situated organs demonstrated a 15% reduction at the anterior-posterior Incidence ranging to a 2% increase at the lateral incidences. Abdominal or asymmetrically situated organs demonstrated a 50% reduction at the anterior-posterior incidence ranging to a 25% increase at the lateral incidences.

  1. The Influence of Shielding on the Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damage

    NASA Technical Reports Server (NTRS)

    Goeorge, Kerry; Cucinotta, Francis A.

    2007-01-01

    Chromosome damage was assessed in human peripheral blood lymphocytes after in vitro exposure to the either Si-28 (490 or 600 MeV/n), Ti-48 (1000 MeV/n), or Fe-56 (600, 1000, or 5000 MeV/n). LET values for these ions ranged from 51 to 184 keV/micron and doses ranged from 10 to 200 cGy. The effect of either aluminum or polyethylene shielding on the induction of chromosome aberrations was investigated for each ion. Chromosome exchanges were measured using fluorescence in situ hybridization (FISH) with whole chromosome probes in cells collected at G2 and mitosis in first division post irradiation after chromosomes were prematurely condensed using calyculin-A. The yield of chromosomal aberrations increased linearly with dose and the relative biological effectiveness (RBE) for the primary beams, estimated from the initial slope of the dose response curve for total chromosomal exchanges with respect to gamma-rays, ranged from 9 to 35. The RBE values increased with LET, reaching a maximum for the 600 MeV/n Fe ions with LET of 184 keV/micron. When the LET of the primary beam was below approximately 100 keV/micron, the addition of shielding material increased the effectiveness per unit dose. Whereas shielding decreased the effectiveness per unit dose when the LET of primary beams was higher than 100 keV/micron. The yield of aberrations correlated with the dose-average LET of the beam after traversal through the shielding.

  2. Pharmacological Studies of NOP Receptor Agonists as Novel Analgesics

    DTIC Science & Technology

    2008-05-01

    in non-human primates. a. Study behavioral effects of ultra- low doses of intrathecal N/OFQ over a wide dose range using a warm water tail...threshold of monkeys. Figure 1 compares the effects of ultra- low doses of intrathecal N/OFQ (i.e., 1 fmol and 1 pmol) with those of a mu opioid...findings indicate that ultra- low doses of intrathecal N/OFQ did not change the monkey’s thermal nociceptive threshold (Figure 1, middle panels

  3. SU-E-J-146: A Research of PET-CT SUV Range for the Online Dose Verification in Carbon Ion Radiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, L; Hu, W; Moyers, M

    2015-06-15

    Purpose: Positron-emitting isotope distributions can be used for the image fusion of the carbon ion planning CT and online target verification PETCT, after radiation in the same decay period,the relationship between the same target volume and the SUV value of different every single fraction dose can be found,then the range of SUV for the radiation target could be decided.So this online range also can provide reference for the correlation and consistency in planning target dose verification and evaluation for the clinical trial. Methods: The Rando head phantom can be used as real body,the 10cc cube volume target contouring is done,beammore » ISO Center depth is 7.6cm and the 90 degree fixed carbon ion beams should be delivered in single fraction effective dose of 2.5GyE,5GyE and 8GyE.After irradiation,390 seconds later the 30 minutes PET-CT scanning is performed,parameters are set to 50Kg virtual weight,0.05mCi activity.MIM Maestro is used for the image processing and fusion,five 16mm diameter SUV spheres have been chosen in the different direction in the target.The average SUV in target for different fraction dose can be found by software. Results: For 10cc volume target,390 seconds decay period,the Single fraction effective dose equal to 2.5Gy,Ethe SUV mean value is 3.42,the relative range is 1.72 to 6.83;Equal to 5GyE,SUV mean value is 9.946,the relative range is 7.016 to 12.54;Equal or above to 8GyE,SUV mean value is 20.496,the relative range is 11.16 to 34.73. Conclusion: Making an evaluation for accuracy of the dose distribution using the SUV range which is from the planning CT with after treatment online PET-CT fusion for the normal single fraction carbon ion treatment is available.Even to the plan which single fraction dose is above 2GyE,in the condition of other parameters all the same,the SUV range is linearly dependent with single fraction dose,so this method also can be used in the hyper-fraction treatment plan.« less

  4. Very low dose gamma irradiation stimulates gaseous exchange and carboxylation efficiency, but inhibits vascular sap flow in groundnut (Arachis hypogaea L.).

    PubMed

    Ahuja, Sumedha; Singh, Bhupinder; Gupta, Vijay Kumar; Singhal, R K; Venu Babu, P

    2014-02-01

    An experiment was carried out to determine the effect of low dose gamma radiation on germination, plant growth, nitrogen and carbon fixation and carbon flow and release characteristics of groundnut. Dry seeds of groundnut variety Trombay groundnut 37A (TG 37A), a radio mutant type developed by Bhabha Atomic Research Centre (BARC), Mumbai, India, were subjected to the pre-sowing treatment of gamma radiation within low to high dose physiological range, i.e., 0.0, 0.0082, 0.0164. 0.0328, 0.0656, 0.1312, 5, 25, 100, 500 Gray (Gy) from a cobalt source ((60)Co). Observations were recorded for the radiation effect on percentage germination, vigour, gas exchange attributes such as photosynthetic rate, stomatal conductance and transpiration rate, chlorophyll content, root exudation in terms of (14)C release, vascular sap flow rate and activities of rate defining carbon and nitrogen assimilating enzymes such as ribulose-1,5-bisphosphate carboxylase (rubisco) and nitrate reductase (NR). Seed germination was increased by 10-25% at the lower doses up to 5 Gy while the improvement in plant vigour in the same dose range was much higher (22-84%) than the unirradiated control. For radiation exposure above 5 Gy, a dose-dependent decline in germination and plant vigour was measured. No significant effect was observed on the photosynthesis at radiation exposure below 5 Gy but above 5 Gy dose there was a decline in the photosynthetic rate. Stomatal conductance and transpiration rate, however, were only inhibited at a high dose of 500 Gy. Leaf rubisco activity and NR activities remained unaffected at all the investigated doses of gamma irradiation. Mean root exudation and sap flow rate of the irradiated plants, irrespective of the dose, was reduced over the unirradiated control more so in a dose-dependent manner. Results indicated that a very low dose of gamma radiation, in centigray to gray range, did not pose any threat and in fact stimulated metabolic functions in such a way to aid growth and development of groundnut plants. It further showed that the radiation threshold for the gas exchange traits and rubisco activity, which ultimately determine the plant health and yield, were higher than compared to the other metabolic attributes and were well beyond 500 Gy and that the dose range above 500 Gy should be targeted to measure lethal effects of radiation on carbon assimilation attributes in leguminous crops, in general, and groundnut in particular.

  5. DSC studies on gamma irradiated poly(vinylidene fluoride) applied to high gamma dose dosimetry

    NASA Astrophysics Data System (ADS)

    Batista, Adriana S. M.; Faria, Luiz O.

    2017-11-01

    Poly(vinylidene fluoride) homopolymer (PVDF) was investigated for use on high gamma dose dosimetry. Samples were irradiated with gamma doses ranging from 100 kGy to 3000 kGy. Differential scanning calorimetry (DSC) was used to construct an unambiguous relationship between the melting transition latent heat (LM) and the absorbed dose (D). DSC thermograms were taken immediately, 1, 2 and 8 months after the irradiation process revealing that the LMx D relationship presented no change for doses ranging from 100 to 2750 kGy. FTIR and UV-Vis spectroscopy data revealed the radio-induction of C˭O and C˭C bonds. These radio-induced bonds were responsible by the chain stiffening and chain oxidation, respectively. SEM microscopy demonstrates that the spherulitic large crystalline structures present in pristine PVDF are destroyed with doses as low as 100 kGy. The DRX analysis revealed that the main effect of high gamma doses in the crystalline structure of PVDF is to provoke a change from the pristine PVDF α-phase to the γ-phase. Both the ability to detect gamma doses in a large dose range and the low fading features make PVDF homopolymers good candidates to be investigated as high gamma dose dosimeters.

  6. Experimental determination of particle range and dose distribution in thick targets through fragmentation reactions of stable heavy ions.

    PubMed

    Inaniwa, Taku; Kohno, Toshiyuki; Tomitani, Takehiro; Urakabe, Eriko; Sato, Shinji; Kanazawa, Mitsutaka; Kanai, Tatsuaki

    2006-09-07

    In radiation therapy with highly energetic heavy ions, the conformal irradiation of a tumour can be achieved by using their advantageous features such as the good dose localization and the high relative biological effectiveness around their mean range. For effective utilization of such properties, it is necessary to evaluate the range of incident ions and the deposited dose distribution in a patient's body. Several methods have been proposed to derive such physical quantities; one of them uses positron emitters generated through projectile fragmentation reactions of incident ions with target nuclei. We have proposed the application of the maximum likelihood estimation (MLE) method to a detected annihilation gamma-ray distribution for determination of the range of incident ions in a target and we have demonstrated the effectiveness of the method with computer simulations. In this paper, a water, a polyethylene and a polymethyl methacrylate target were each irradiated with stable (12)C, (14)N, (16)O and (20)Ne beams. Except for a few combinations of incident beams and targets, the MLE method could determine the range of incident ions R(MLE) with a difference between R(MLE) and the experimental range of less than 2.0 mm under the circumstance that the measurement of annihilation gamma rays was started just after the irradiation of 61.4 s and lasted for 500 s. In the process of evaluating the range of incident ions with the MLE method, we must calculate many physical quantities such as the fluence and the energy of both primary ions and fragments as a function of depth in a target. Consequently, by using them we can obtain the dose distribution. Thus, when the mean range of incident ions is determined with the MLE method, the annihilation gamma-ray distribution and the deposited dose distribution can be derived simultaneously. The derived dose distributions in water for the mono-energetic heavy-ion beams of four species were compared with those measured with an ionization chamber. The good agreement between the derived and the measured distributions implies that the deposited dose distribution in a target can be estimated from the detected annihilation gamma-ray distribution with a positron camera.

  7. TH-AB-207A-06: The Use of Realistic Phantoms to Predict CT Dose to Pediatric Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carver, D; Kost, S; Fraser, N

    Purpose: To predict pediatric patient dose from diagnostic CT scans using Monte Carlo simulation of realistic reference phantoms of various ages, weights, and heights. Methods: A series of deformable pediatric reference phantoms using Non-Uniform Rational B-Splines (NURBS) was developed for a large range of ages, percentiles, and reference anatomy. Individual bones were modeled using age-dependent factors, and red marrow was modeled as functions of age and spatial distribution based on Cristy1. Organ and effective doses for the phantom series were calculated using Monte Carlo simulation of chest, abdominopelvic, and chest-abdomen-pelvis CT exams. Non-linear regression was performed to determine the relationshipmore » between dose-length-product (DLP)-normalized organ and effective doses and phantom diameter. Patient-specific voxel computational phantoms were also created by manual segmentation of previously acquired CT images for 40 pediatric patients (0.7 to 17 years). Organ and effective doses were determined by Monte Carlo simulation of these patient-specific phantoms. Each patient was matched to the closest pediatric reference phantom based primarily on age and diameter for all major organs within the torso. Results: A total of 80 NURBS phantoms were created ranging from newborn to 15 years with height/weight percentiles from 10 to 90%. Organ and effective dose normalized by DLP correlated strongly with exponentially decreasing average phantom diameter (R{sup 2} > 0.95 for most organs). A similar relationship was determined for the patient-specific voxel phantoms. Differences between patient-phantom matched organ-dose values ranged from 0.37 to 2.39 mGy (2.87% to 22.1%). Conclusion: Dose estimation using NURBS-based pediatric reference phantoms offers the ability to predict patient dose before and after CT examinations, and physicians and scientists can use this information in their analysis of dose prescriptions for particular subjects and study types. This may lead to practices that minimize radiation dose while still achieving high quality images and, ultimately, improved patient care. NIH/NCI 1 R01 CA155400-01A1.« less

  8. Alternative chitosan-based EPR dosimeter applicable for a relatively wide range of gamma radiation doses

    NASA Astrophysics Data System (ADS)

    Piroonpan, Thananchai; Katemake, Pichayada; Panritdam, Eagkapong; Pasanphan, Wanvimol

    2017-12-01

    Chitosan biopolymer is proposed as an alternative EPR dosimeter. Its ability to be EPR dosimeter was studied in comparison with the conventional alanine, sugars (i.e., glucose and sucrose), formate derivatives (i.e., lithium (Li), magnesium (Mg), and calcium (Ca) formate). Ethylene vinyl acetate (EVA) and paraffin were used as binder for the preparation of composite EPR dosimeter. Dose responses of all materials were investigated in a wide dose range of radiation doses, i.e., low-level (0-1 kGy), medium-level (1-10 kGy) and high-level (10-100 kGy). The EPR dosimeter properties were studied under different parameters, i.e., microwave power, materials contents, absorbed doses, storage conditions and post-irradiation effects. Li-formate showed a simple EPR spectrum and exhibited superior radiation response for low-dose range; whereas chitosan and sucrose exhibited linear dose response in all studied dose ranges. The EPR signals of chitosan exhibited similar stability as glucose, Li-formate and alanine at ambient temperature after irradiation as long as a year. All EPR signals of the studied materials were affected post-irradiation temperature and humidity after gamma irradiation. The EPR signal of chitosan exhibited long-term stability and it was not sensitive to high storage temperatures and humidity values after irradiation. Chitosan has a good merit as the alternative bio-based material for a stable EPR dosimeter in a wide range of radiation-absorbed doses.

  9. Effective dose equivalent on the ninth Shuttle--Mir mission (STS-91)

    NASA Technical Reports Server (NTRS)

    Yasuda, H.; Badhwar, G. D.; Komiyama, T.; Fujitaka, K.

    2000-01-01

    Organ and tissue doses and effective dose equivalent were measured using a life-size human phantom on the ninth Shuttle-Mir Mission (STS-91, June 1998), a 9.8-day spaceflight at low-Earth orbit (about 400 km in altitude and 51.65 degrees in inclination). The doses were measured at 59 positions using a combination of thermoluminescent dosimeters of Mg(2)SiO(4):Tb (TDMS) and plastic nuclear track detectors (PNTD). In correcting the change in efficiency of the TDMS, it was assumed that reduction of efficiency is attributed predominantly to HZE particles with energy greater than 100 MeV nucleon(-1). A conservative calibration curve was chosen for determining LET from the PNTD track-formation sensitivities. The organ and tissue absorbed doses during the mission ranged from 1.7 to 2.7 mGy and varied by a factor of 1.6. The dose equivalent ranged from 3.4 to 5.2 mSv and varied by a factor of 1.5 on the basis of the dependence of Q on LET in the 1990 recommendations of the ICRP. The effective quality factor (Q(e)) varied from 1.7 to 2.4. The dose equivalents for several radiation-sensitive organs, such as the stomach, lung, gonad and breast, were not significantly different from the skin dose equivalent (H(skin)). The effective dose equivalent was evaluated as 4.1 mSv, which was about 90% of the H(skin).

  10. Acute effects of THC on time perception in frequent and infrequent cannabis users.

    PubMed

    Sewell, R Andrew; Schnakenberg, Ashley; Elander, Jacqueline; Radhakrishnan, Rajiv; Williams, Ashley; Skosnik, Patrick D; Pittman, Brian; Ranganathan, Mohini; D'Souza, D Cyril

    2013-03-01

    Cannabinoids have been shown to alter time perception, but existing literature has several limitations. Few studies have included both time estimation and production tasks, few control for subvocal counting, most had small sample sizes, some did not record subjects' cannabis use, many tested only one dose, and used either oral or inhaled administration of Δ⁹-tetrahydrocannabinol (THC), leading to variable pharmacokinetics, and some used whole-plant cannabis containing cannabinoids other than THC. Our study attempted to address these limitations. This study aims to characterize the acute effects of THC and frequent cannabis use on seconds-range time perception. THC was hypothesized to produce transient, dose-related time overestimation and underproduction. Frequent cannabis smokers were hypothesized to show blunted responses to these alterations. IV THC was administered at doses from 0.015 to 0.05 mg/kg to 44 subjects who participated in several double-blind, randomized, counterbalanced, crossover, placebo-controlled studies. Visual time estimation and production tasks in the seconds range were presented to subjects three times on each test day. All doses induced time overestimation and underproduction. Chronic cannabis use had no effect on baseline time perception. While infrequent/nonsmokers showed temporal overestimation at medium and high doses and temporal underproduction at all doses, frequent cannabis users showed no differences. THC effects on time perception were not dose related. A psychoactive dose of THC increases internal clock speed as indicated by time overestimation and underproduction. This effect is not dose related and is blunted in chronic cannabis smokers who did not otherwise have altered baseline time perception.

  11. Nonmonotonic dose response curves (NMDRCs) are common after Estrogen or Androgen signaling pathway disruption. Fact or Falderal? ###SETAC

    EPA Science Inventory

    The shape of the dose response curve in the low dose region has been debated since the late 1940s. The debate originally focused on linear no threshold (LNT) vs threshold responses in the low dose range for cancer and noncancer related effects. Recently, claims have arisen tha...

  12. Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang Yakun; Li Xiang; Paul Segars, W.

    Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representativemore » CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated male and female stylized phantoms. Results: For fully irradiated organs, average coefficients of variation (COV) ranged from 0.07 to 0.22 across the four male phantoms and from 0.06 to 0.18 across the four female phantoms; for partially irradiated organs, average COV ranged from 0.13 to 0.30 across the four male phantoms and from 0.15 to 0.30 across the four female phantoms. Doses to the testes, breasts, and esophagus showed large variations between phantoms. COV for gender-averaged effective dose and k factor ranged from 0.03 to 0.23 and from 0.06 to 0.30, respectively. COV for male risk index and q factor ranged from 0.06 to 0.30 and from 0.05 to 0.36, respectively; COV for female risk index and q factor ranged from 0.06 to 0.49 and from 0.07 to 0.54, respectively. Conclusions: Despite closely matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms.« less

  13. Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

    PubMed Central

    Zhang, Yakun; Li, Xiang; Paul Segars, W.; Samei, Ehsan

    2012-01-01

    Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated male and female stylized phantoms. Results: For fully irradiated organs, average coefficients of variation (COV) ranged from 0.07 to 0.22 across the four male phantoms and from 0.06 to 0.18 across the four female phantoms; for partially irradiated organs, average COV ranged from 0.13 to 0.30 across the four male phantoms and from 0.15 to 0.30 across the four female phantoms. Doses to the testes, breasts, and esophagus showed large variations between phantoms. COV for gender-averaged effective dose and k factor ranged from 0.03 to 0.23 and from 0.06 to 0.30, respectively. COV for male risk index and q factor ranged from 0.06 to 0.30 and from 0.05 to 0.36, respectively; COV for female risk index and q factor ranged from 0.06 to 0.49 and from 0.07 to 0.54, respectively. Conclusions: Despite closely matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms. PMID:22755721

  14. Gastrointestinal Dose-Histogram Effects in the Context of Dose-Volume–Constrained Prostate Radiation Therapy: Analysis of Data From the RADAR Prostate Radiation Therapy Trial

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ebert, Martin A., E-mail: Martin.Ebert@health.wa.gov.au; School of Physics, University of Western Australia, Perth, Western Australia; Foo, Kerwyn

    Purpose: To use a high-quality multicenter trial dataset to determine dose-volume effects for gastrointestinal (GI) toxicity following radiation therapy for prostate carcinoma. Influential dose-volume histogram regions were to be determined as functions of dose, anatomical location, toxicity, and clinical endpoint. Methods and Materials: Planning datasets for 754 participants in the TROG 03.04 RADAR trial were available, with Late Effects of Normal Tissues (LENT) Subjective, Objective, Management, and Analytic (SOMA) toxicity assessment to a median of 72 months. A rank sum method was used to define dose-volume cut-points as near-continuous functions of dose to 3 GI anatomical regions, together with amore » comprehensive assessment of significance. Univariate and multivariate ordinal regression was used to assess the importance of cut-points at each dose. Results: Dose ranges providing significant cut-points tended to be consistent with those showing significant univariate regression odds-ratios (representing the probability of a unitary increase in toxicity grade per percent relative volume). Ranges of significant cut-points for rectal bleeding validated previously published results. Separation of the lower GI anatomy into complete anorectum, rectum, and anal canal showed the impact of mid-low doses to the anal canal on urgency and tenesmus, completeness of evacuation and stool frequency, and mid-high doses to the anorectum on bleeding and stool frequency. Derived multivariate models emphasized the importance of the high-dose region of the anorectum and rectum for rectal bleeding and mid- to low-dose regions for diarrhea and urgency and tenesmus, and low-to-mid doses to the anal canal for stool frequency, diarrhea, evacuation, and bleeding. Conclusions: Results confirm anatomical dependence of specific GI toxicities. They provide an atlas summarizing dose-histogram effects and derived constraints as functions of anatomical region, dose, toxicity, and endpoint for informing future radiation therapy planning.« less

  15. The Influence of Shielding on the Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damages

    NASA Technical Reports Server (NTRS)

    George, K.; Cucinotta, F. A.

    2006-01-01

    Chromosome damage was assessed in human peripheral blood lymphocytes after in vitro exposure to the either Si-28 (490 or 600 MeV/n), Ti-48 (1000 MeV/n), or Fe-56 (600, 1000, or 5000 MeV/n). LET values for these ions ranged from approximately 50 to 174 keV/micrometers and doses ranged from 10 to 200 cGy. The effect of either aluminum or polyethylene shielding on the induction of chromosome aberrations was investigated for each ion. Chromosome exchanges were measured using fluorescence in situ hybridization (FISH) with whole chromosome probes in cells collected 48-56 hours after irradiation using a chemical-induced premature chromosome condensation (PCC) technique. The yield of chromosomal aberrations increased linearly with dose and the relative biological effectiveness (RBE) for the primary beams, estimated from the initial slope of the dose response curve for total chromosomal exchanges with respect to gamma-rays, ranged from 14 to 35. The RBE values increased with LET, reaching a maximum for the 1 GeV/n Fe ions with LET of 150 keV/micrometers, and decreased with further increases in LET. When LET of the primary beam was in the region of increasing RBE (i.e. below approximately 100 keV/micrometers), the addition of shielding material increased the effectiveness per unit dose. Whereas shielding decreased the effectiveness per unit dose when the LET of the primary particle beam was higher than 150 keV/micrometers.

  16. Evaluating health risks from occupational exposure to pesticides and the regulatory response.

    PubMed Central

    Woodruff, T J; Kyle, A D; Bois, F Y

    1994-01-01

    In this study, we used measurements of occupational exposures to pesticides in agriculture to evaluate health risks and analyzed how the federal regulatory program is addressing these risks. Dose estimates developed by the State of California from measured occupational exposures to 41 pesticides were compared to standard indices of acute toxicity (LD50) and chronic effects (reference dose). Lifetime cancer risks were estimated using cancer potencies. Estimated absorbed daily doses for mixers, loaders, and applicators of pesticides ranged from less than 0.0001% to 48% of the estimated human LD50 values, and doses for 10 of 40 pesticides exceeded 1% of the estimated human LD50 values. Estimated lifetime absorbed daily doses ranged from 0.1% to 114,000% of the reference doses developed by the U.S. Environmental Protection Agency, and doses for 13 of 25 pesticides were above them. Lifetime cancer risks ranged from 1 per million to 1700 per million, and estimates for 12 of 13 pesticides were above 1 per million. Similar results were obtained for field workers and flaggers. For the pesticides examined, exposures pose greater risks of chronic effects than acute effects. Exposure reduction measures, including use of closed mixing systems and personal protective equipment, significantly reduced exposures. Proposed regulations rely primarily on requirements for personal protective equipment and use restrictions to protect workers. Chronic health risks are not considered in setting these requirements. Reviews of pesticides by the federal pesticide regulatory program have had little effect on occupational risks. Policy strategies that offer immediate protection for workers and that are not dependent on extensive review of individual pesticides should be pursued. Images Figure 1. PMID:7713022

  17. Mutations induced in Tradescantia by small doses of X-rays and neutrons - Analysis of dose-response curves.

    NASA Technical Reports Server (NTRS)

    Sparrow, A. H.; Underbrink, A. G.; Rossi, H. H.

    1972-01-01

    Dose-response curves for pink somatic mutations in Tradescantia stamen hairs were analyzed after neutron and X-ray irradiation with doses ranging from a fraction of a rad to the region of saturation. The dose-effect relation for neutrons indicates a linear dependence from 0.01 to 8 rads; between 0.25 and 5 rads, a linear dependence is indicated for X-rays also. As a consequence the relative biological effectiveness reaches a constant value (about 50) at low doses. The observations are in good agreement with the predictions of the theory of dual radiation action and support its interpretation of the effects of radiation on higher organisms. The doubling dose of X-rays was found to be nearly 1 rad.

  18. Food irradiation dosimetry by opti-chromic technique

    NASA Astrophysics Data System (ADS)

    Zhan-Jun, Liu; Radak, B. B.; McLaughlin, W. L.

    The measurement of gamma-radiation quantities, e.g., absorbed dose in materials such as water, plastics, foodstuffs, is a convenient means of quality assurance in radiation processing. A new dosimetry system, called the "Opti-Chromic" dosimeter, is commercially available in large batches for use as a routine measurement system in the absorbed dose range 10 to 2x10 4 Gy. This dose range covers most food irradiation applications. A statistical evaluation was made of the reproducibility of this dosimeter for measuring doses appropriate for the disinfestation and shelf-life extension of many foods, namely 10 to 2x10 3 Gy. In addition, the small dosimeters were used to map absorbed dose distributions in boxes of foods having four different bulk densities (grapefruit, lemons, peanuts, and wheat bran). It is demonstrated that the dosimeters are rugged and stable enough to be used over a wide temperature and humidity range, and, in fact, can be placed in such environments as the inside of citrus fruits without adverse effects on their ability to give satisfactory dose assessment.

  19. Dosimetry investigation of MOSFET for clinical IMRT dose verification.

    PubMed

    Deshpande, Sudesh; Kumar, Rajesh; Ghadi, Yogesh; Neharu, R M; Kannan, V

    2013-06-01

    In IMRT, patient-specific dose verification is followed regularly at each centre. Simple and efficient dosimetry techniques play a very important role in routine clinical dosimetry QA. The MOSFET dosimeter offers several advantages over the conventional dosimeters such as its small detector size, immediate readout, immediate reuse, multiple point dose measurements. To use the MOSFET as routine clinical dosimetry system for pre-treatment dose verification in IMRT, a comprehensive set of experiments has been conducted, to investigate its linearity, reproducibility, dose rate effect and angular dependence for 6 MV x-ray beam. The MOSFETs shows a linear response with linearity coefficient of 0.992 for a dose range of 35 cGy to 427 cGy. The reproducibility of the MOSFET was measured by irradiating the MOSFET for ten consecutive irradiations in the dose range of 35 cGy to 427 cGy. The measured reproducibility of MOSFET was found to be within 4% up to 70 cGy and within 1.4% above 70 cGy. The dose rate effect on the MOSFET was investigated in the dose rate range 100 MU/min to 600 MU/min. The response of the MOSFET varies from -1.7% to 2.1%. The angular responses of the MOSFETs were measured at 10 degrees intervals from 90 to 270 degrees in an anticlockwise direction and normalized at gantry angle zero and it was found to be in the range of 0.98 ± 0.014 to 1.01 ± 0.014. The MOSFETs were calibrated in a phantom which was later used for IMRT verification. The measured calibration coefficients were found to be 1 mV/cGy and 2.995 mV/cGy in standard and high sensitivity mode respectively. The MOSFETs were used for pre-treatment dose verification in IMRT. Nine dosimeters were used for each patient to measure the dose in different plane. The average variation between calculated and measured dose at any location was within 3%. Dose verification using MOSFET and IMRT phantom was found to quick and efficient and well suited for a busy radiotherapy department.

  20. Cerebral radioprotection by pentobarbital: Dose-response characteristics and association with GABA agonist activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Olson, J.J.; Friedman, R.; Orr, K.

    1990-05-01

    Pentobarbital reduces cerebral radiation toxicity; however, the mechanism of this phenomenon remains unknown. As an anesthetic and depressant of cerebral metabolism, pentobarbital induces its effects on the central nervous system by stimulating the binding of gamma-aminobutyric acid (GABA) to its receptor and by inhibiting postsynaptic excitatory amino acid activity. The purpose of this study is to investigate the role of these actions as well as other aspects of the radioprotective activity of pentobarbital. Fischer 344 rats were separated into multiple groups and underwent two dose-response evaluations. In one set of experiments to examine the relationship of radioprotection to pentobarbital dose,more » a range of pentobarbital doses (0 to 75 mg/kg) were given intraperitoneally prior to a constant-level radiation dose (70 Gy). In a second series of experiments to determine the dose-response relationship of radiation protection to radiation dose, a range of radiation doses (10 to 90 Gy) were given with a single pentobarbital dose. Further groups of animals were used to evaluate the importance of the timing of pentobarbital administration, the function of the (+) and (-) isomers of pentobarbital, and the role of an alternative GABA agonist (diazepam). In addition, the potential protective effects of alternative methods of anesthesia (ketamine) and induction of cerebral hypometabolism (hypothermia) were examined. Enhancement of survival time from acute radiation injury due to high-dose single-fraction whole-brain irradiation was maximal with 60 mg/kg of pentobarbital, and occurred over the range of all doses examined between 30 to 90 Gy. Protection was seen only in animals that received the pentobarbital before irradiation. Administration of other compounds that enhance GABA binding (Saffan and diazepam) also significantly enhanced survival time.« less

  1. Spatial Prediction of Coxiella burnetii Outbreak Exposure via Notified Case Counts in a Dose-Response Model.

    PubMed

    Brooke, Russell J; Kretzschmar, Mirjam E E; Hackert, Volker; Hoebe, Christian J P A; Teunis, Peter F M; Waller, Lance A

    2017-01-01

    We develop a novel approach to study an outbreak of Q fever in 2009 in the Netherlands by combining a human dose-response model with geostatistics prediction to relate probability of infection and associated probability of illness to an effective dose of Coxiella burnetii. The spatial distribution of the 220 notified cases in the at-risk population are translated into a smooth spatial field of dose. Based on these symptomatic cases, the dose-response model predicts a median of 611 asymptomatic infections (95% range: 410, 1,084) for the 220 reported symptomatic cases in the at-risk population; 2.78 (95% range: 1.86, 4.93) asymptomatic infections for each reported case. The low attack rates observed during the outbreak range from (Equation is included in full-text article.)to (Equation is included in full-text article.). The estimated peak levels of exposure extend to the north-east from the point source with an increasing proportion of asymptomatic infections further from the source. Our work combines established methodology from model-based geostatistics and dose-response modeling allowing for a novel approach to study outbreaks. Unobserved infections and the spatially varying effective dose can be predicted using the flexible framework without assuming any underlying spatial structure of the outbreak process. Such predictions are important for targeting interventions during an outbreak, estimating future disease burden, and determining acceptable risk levels.

  2. Use of mode of action data to inform a dose-response assessment for bladder cancer following exposure to inorganic arsenic.

    PubMed

    Gentry, P R; Yager, J W; Clewell, R A; Clewell, H J

    2014-10-01

    In the recent National Research Council report on conducting a dose-response assessment for inorganic arsenic, the committee remarked that mode of action data should be used, to the extent possible, to extrapolate below the observed range for epidemiological studies to inform the shape of the dose-response curve. Recent in vitro mode of action studies focused on understanding the development of bladder cancer following exposure to inorganic arsenic provide data to inform the dose-response curve. These in vitro data, combined with results of bladder cancer epidemiology studies, inform the dose-response curve in the low-dose region, and include values for both pharmacokinetic and pharmacodynamic variability. Integration of these data provides evidence of a range of concentrations of arsenic for which no effect on the bladder would be expected. Specifically, integration of these results suggest that arsenic exposures in the range of 7-43 ppb in drinking water are exceedingly unlikely to elicit changes leading to key events in the development of cancer or noncancer effects in bladder tissue. These findings are consistent with the lack of evidence for bladder cancer following chronic ingestion of arsenic water concentrations <100 ppb in epidemiological studies. Copyright © 2014 Elsevier Ltd. All rights reserved.

  3. Occupational dose in interventional radiology procedures.

    PubMed

    Chida, Koichi; Kaga, Yuji; Haga, Yoshihiro; Kataoka, Nozomi; Kumasaka, Eriko; Meguro, Taiichiro; Zuguchi, Masayuki

    2013-01-01

    Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.

  4. Acute effects of a wild green-oat (Avena sativa) extract on cognitive function in middle-aged adults: A double-blind, placebo-controlled, within-subjects trial.

    PubMed

    Kennedy, David O; Jackson, Philippa A; Forster, Joanne; Khan, Julie; Grothe, Torsten; Perrinjaquet-Moccetti, Tania; Haskell-Ramsay, Crystal F

    2017-02-01

    A wild green-oats extract (Neuravena ® ) containing a range of potentially bioactive components, including flavonoids and triterpene saponins, has previously been shown to enhance animal stress responses and memory, and improve cognitive performance in humans at a dose of 1600 mg. Methods This double-blind, placebo-controlled, counterbalanced cross-over study assessed the effects of single doses of the green-oat extract (GOE) across a broad range of cognitive domains in healthy adults aged 40-65 years who self-reported that they felt that their memory had declined with age. Participants attended on six occasions, receiving a single dose of either placebo, 800, or 1600 mg GOE on each occasion, with the counterbalanced order of treatments repeated twice for each participant. Cognitive function was assessed with a range of computerized tasks measuring attention, spatial/working/episodic memory, and executive function pre-dose and at 1, 2.5, 4, and 6 hours post-dose. Results The results showed that 800mg GOE increased the speed of performance across post-dose assessments on a global measure including data from all of the timed tasks. It also improved performance of a delayed word recall task in terms of errors and an executive function task (Peg and Ball) in terms of decreased thinking time and overall completion time. Working memory span (Corsi blocks) was also increased, but only on the second occasion that this dose was taken. Discussion These results confirm the acute cognitive effects of GOE seen in previous research, and suggest that the optimal dose lies at or below 800 mg.

  5. Dose rate effect on micronuclei induction in human blood lymphocytes exposed to single pulse and multiple pulses of electrons.

    PubMed

    Acharya, Santhosh; Bhat, N N; Joseph, Praveen; Sanjeev, Ganesh; Sreedevi, B; Narayana, Y

    2011-05-01

    The effects of single pulses and multiple pulses of 7 MV electrons on micronuclei (MN) induction in cytokinesis-blocked human peripheral blood lymphocytes (PBLs) were investigated over a wide range of dose rates per pulse (instantaneous dose rate). PBLs were exposed to graded doses of 2, 3, 4, 6, and 8 Gy of single electron pulses of varying pulse widths at different dose rates per pulse, ranging from 1 × 10(6) Gy s(-1) to 3.2 × 10(8) Gy s(-1). Different dose rates per pulse were achieved by changing the dose per electron pulse by adjusting the beam current and pulse width. MN yields per unit absorbed dose after irradiation with single electron pulses were compared with those of multiple pulses of electrons. A significant decrease in the MN yield with increasing dose rates per pulse was observed, when dose was delivered by a single electron pulse. However, no reduction in the MN yield was observed when dose was delivered by multiple pulses of electrons. The decrease in the yield at high dose rates per pulse suggests possible radical recombination, which leads to decreased biological damage. Cellular response to the presence of very large numbers of chromosomal breaks may also alter the damage.

  6. Chromosome translocations in T. scripta: the dose-rate effect and in vivo lymphocyte radiation response.

    PubMed

    Ulsh, B A; Whicker, F W; Congdon, J D; Bedford, J S; Hinton, T G

    2001-01-01

    Using a whole-chromosome FISH painting probe we previously developed for chromosome 1 of the yellow-bellied slider turtle (Trachemys scripta), we investigated the dose-rate effect for radiation-induced symmetrical translocations in T. scripta fibroblasts and lymphocytes. The dose rate below which no reduction in effect per unit dose is observed with further dose protraction was approximately 23 cGy h(-1). We estimated the whole-genome spontaneous background level of complete, apparently simple symmetrical translocations in T. scripta lymphocytes to be approximately 1.20 x 10(-3)/cell projected from aberrations occurring in chromosome 1. Similar spontaneous background levels reported for humans are some 6- to 25-fold higher, ranging from about 6 x 10(-3) to 3.4 x 10(-2) per cell. This relatively low background level for turtles would be a significant advantage for resolution of effects at low doses and dose rates. We also chronically irradiated turtles over a range of doses from 0-8 Gy delivered at approximately 5.5 cGy h(-1) and constructed a lymphocyte dose-response curve for complete, apparently simple symmetrical translocations suitable for use with animals chronically exposed to radiation in contaminated environments. The best-fitting calibration curve (not constrained through the zero dose estimate) was of the form Y(as) = c + aD + bD(2), where Y(as) was the number of apparently simple symmetrical translocations per cell, D was the dose (Gy), a = (0.0058 +/- 0.0009), b = (-0.00033 +/- 0.00011), and c = (0.0015 +/- 0.0013). With additional whole-chromosome probes to improve sensitivity, environmental biodosimetry using stable chromosome translocations could provide a practical and genetically relevant measurement end point for ecological risk assessments and biomonitoring programs.

  7. The effect of SLCO1B1 polymorphism on repaglinide pharmacokinetics persists over a wide dose range

    PubMed Central

    Kalliokoski, Annikka; Neuvonen, Mikko; Neuvonen, Pertti J; Niemi, Mikko

    2008-01-01

    WHAT IS ALREADY KNOWN ABOUT THIS SUBJECTOrganic anion transporting polypeptide 1B1 is an influx transporter expressed on the basolateral membrane of hepatocytes.A common single nucleotide polymorphism, c.521T→C (p.Val174Ala), of the SLCO1B1 gene has been associated with increased plasma repaglinide concentrations in healthy volunteers.Previous studies at low repaglinide doses have suggested that the effect of SLCO1B1 c.521T→C polymorphism on the pharmacokinetics of repaglinide could be dose-dependent. WHAT THIS STUDY ADDSRepaglinide peak plasma concentration and area under the plasma concentration–time curve increased linearly along with repaglinide dose ranging from 0.25 to 2 mg in both the predominant c.521TT and rare c.521CC genotype group.The effect of SLCO1B1 c.521T→C polymorphism on repaglinide pharmacokinetics persists over a wide dose range. AIMS To establish whether the effect of SLCO1B1[encoding organic anion transporting polypeptide 1B1 (OATP1B1)] c.521T→C (p.Val174Ala) polymorphism on the pharmacokinetics of repaglinide is dose-dependent. METHODS Twelve healthy volunteers with the SLCO1B1 c.521TT genotype (controls) and eight with the c.521CC genotype ingested a single 0.25-, 0.5-, 1- or 2-mg dose of repaglinide in a dose-escalation study with a wash-out period of ≥1 week. RESULTS The mean area under the plasma concentration–time curve from time 0 to infinity (AUC0–∞) of 0.25, 0.5, 1 or 2 mg repaglinide was 82% (95% confidence interval 47, 125), 72% (24, 138), 56% (24, 95) or 108% (59, 171) (P ≤ 0.001) larger in participants with the SLCO1B1 c.521CC genotype than in those with the c.521TT genotype, respectively. Repaglinide peak plasma concentration and AUC0–∞ increased linearly along with repaglinide dose in both genotype groups (r > 0.88, P < 0.001). There was a tendency towards lower blood glucose concentrations after repaglinide administration in the participants with the c.521CC genotype than in those with the c.521TT genotype. CONCLUSIONS The effect of SLCO1B1 c.521T→C polymorphism on the pharmacokinetics of repaglinide persists throughout the clinically relevant dose range. PMID:18823304

  8. Estimation of the total effective dose from low-dose CT scans and radiopharmaceutical administrations delivered to patients undergoing SPECT/CT explorations.

    PubMed

    Montes, Carlos; Tamayo, Pilar; Hernandez, Jorge; Gomez-Caminero, Felipe; García, Sofia; Martín, Carlos; Rosero, Angela

    2013-08-01

    Hybrid imaging, such as SPECT/CT, is used in routine clinical practice, allowing coregistered images of the functional and structural information provided by the two imaging modalities. However, this multimodality imaging may mean that patients are exposed to a higher radiation dose than those receiving SPECT alone. The study aimed to determine the radiation exposure of patients who had undergone SPECT/CT examinations and to relate this to the Background Equivalent Radiation Time (BERT). 145 SPECT/CT studies were used to estimate the total effective dose to patients due to both radiopharmaceutical administrations and low-dose CT scans. The CT contribution was estimated by the Dose-Length Product method. Specific conversion coefficients were calculated for SPECT explorations. The radiation dose from low-dose CTs ranged between 0.6 mSv for head and neck CT and 2.6 mSv for whole body CT scan, representing a maximum of 1 year of background radiation exposure. These values represent a decrease of 80-85% with respect to the radiation dose from diagnostic CT. The radiation exposure from radiopharmaceutical administration varied from 2.1 mSv for stress myocardial perfusion SPECT to 26 mSv for gallium SPECT in patients with lymphoma. The BERT ranged from 1 to 11 years. The contribution of low-dose CT scans to the total radiation dose to patients undergoing SPECT/CT examinations is relatively low compared with the effective dose from radiopharmaceutical administration. When a CT scan is only acquired for anatomical localization and attenuation correction, low-dose CT scan is justified on the basis of its lower dose.

  9. Assessment of the risk of solar ultraviolet radiation to amphibians. III. Prediction of impacts in selected northern midwestern wetlands.

    PubMed

    Diamond, Stephen A; Peterson, Gregory S; Tietge, Joseph E; Ankley, Gerald T

    2002-07-01

    Solar ultraviolet radiation, especially UVB (280-320 nm), has been hypothesized to be at least partially responsible for adverse effects (e.g., declines and malformations) in amphibian species throughout the world. Evaluation of this hypothesis has been limited by the paucity of high-quality UV dose-response data and reliable estimates of typical UV doses that occur in amphibian habitats. In this preliminary risk assessment for effects of UV radiation on amphibians, dose-response relationships quantified in outdoor experiments were compared with UV exposure estimates for 26 wetlands in northern Minnesota and Wisconsin. A comparison of wetland doses, derived from model prediction, historical data, and dissolved organic carbon (DOC) characterization, with experimental effects levels for green (R. clamitans), northern leopard (R. pipiens), and mink (R. septentrionalis) frogs indicated that the risk of mortality and malformations due to UV exposure is low for the majority of wetlands evaluated. Wetland UV dose, averaged over the entire breeding season, exceeded effects doses for mortality for all three species in two of the 26 wetlands examined and for one species in an additional wetland. On the basis of evidence that shorter term doses caused mortality in amphibian larvae, 3-day doses were also evaluated. In three of the wetlands examined, 3-day doses in excess of 85% of full sunlight (the level that appeared to trigger effects in controlled experimentation) occurred at frequencies ranging 22-100% for all three species and at frequencies ranging from 15% to 58% for R. pipiens and R. septentrionalis in three additional wetlands. Risk of malformation in R. pipiens was apparent in five of the 26 wetlands evaluated. Overall, estimated UVB doses in 21 of the wetlands never exceeded experimental effects doses for mortality or malformations. These results suggest that most amphibians are not currently at significant risk for UVB effects in northern Minnesota and Wisconsin wetlands. However, continued reduction of ozone and other global climate change effects may increase UV doses in wetlands, suggesting that the risk of UV to amphibians should continue to be monitored and studied.

  10. Efficacy and Safety of OnabotulinumtoxinA Treatment of Forehead Lines: A Multicenter, Randomized, Dose-Ranging Controlled Trial.

    PubMed

    Solish, Nowell; Rivers, Jason K; Humphrey, Shannon; Muhn, Channy; Somogyi, Chris; Lei, Xiaofang; Bhogal, Meetu; Caulkins, Carrie

    2016-03-01

    Various onabotulinumtoxinA doses are effective in treating forehead lines (FHL), with a trend toward lower doses. To evaluate efficacy and safety of onabotulinumtoxinA dose-ranging treatment of FHL when the frontalis area and glabellar complex are treated together. Adults with moderate-to-severe FHL received onabotulinumtoxinA 40 U (FHL, 20 U; glabellar lines [GL], 20 U), 30 U (FHL, 10 U; GL, 20 U), or placebo. Response was assessed at weeks 1, 2, day 30, and monthly to day 180. Coprimary efficacy end points were investigator- and subject-assessed Facial Wrinkle Scale scores of none or mild (day 30). Patient-reported outcomes, onset/duration of effect, and adverse events (AEs) were evaluated. Responder rates (investigator/subject, respectively) were 40-U group, 91.2%/89.5%; 30-U group, 86.4%/81.4%; placebo, 1.7%/5.1%. OnabotulinumtoxinA resulted in significantly greater responder rates than placebo (p < .001). Adverse events were mild to moderate and similar between groups (most common AEs: nasopharyngitis [4.6%] and headache [4.0%]). Treatment of FHL with onabotulinumtoxinA 40 and 30 U (in frontalis and glabellar complex muscles) was tolerable, effective, and sustained. Both doses significantly reduced FHL severity; however, the 40-U dose demonstrated a trend toward greater sustained benefit and longer duration of effect versus the 30-U dose, with similar AE rates.

  11. High-intensity corneal collagen crosslinking with riboflavin and UVA in rat cornea.

    PubMed

    Zhu, Yirui; Reinach, Peter S; Zhu, Hanlei; Tan, Qiufan; Zheng, Qinxiang; Qu, Jia; Chen, Wei

    2017-01-01

    Corneal collagen cross-linking (CXL) halts human corneal ectasias progression by increasing stromal mechanical stiffness. Although some reports describe that this procedure is effective in dealing with some infectious and immunologic corneal thinning diseases, there is a need for more animal models whose corneal thickness more closely resemble those occurring in these patients. To meet this need, we describe here high-intensity protocols that are safe and effective for obtaining CXL in rat corneas. Initially, a range of potentially effective UVA doses were evaluated based on their effectiveness in increasing tissue enzymatic resistance to dissolution. At UVA doses higher than a threshold level of 0.54 J/cm2, resistance to enzymatic digestion increased relative to that in non-irradiated corneas. Based on the theoretical threshold CXL dose, a CXL regimen was established in which the UVA tissue irradiance was 9 mW/cm2, which was delivered at doses of either 2.16, 2.7 or 3.24 J/cm2. Their dose dependent effects were evaluated on ocular surface morphological integrity, keratocyte apoptotic frequency, tissue thickness and endothelial cell layer density. Doses of 2.16 and 2.7 J/cm2 transiently decreased normal corneal transparency and increased thickness. These effects were fully reversed after 14 days. In contrast, 3.24 J/cm2 had more irreversible side effects. Three days after treatment, apoptotic frequency in the CXL-2.16 group was lower than that at higher doses. Endothelial cell losses remained evident only in the CXL-3.24 group at 42 days posttreatment. Stromal fiber thickening was evident in all the CXL-treated groups. We determined both the threshold UVA dose using the high-intensity CXL procedure and identified an effective dose range that provides optimal CXL with minimal transient side effects in the rat cornea. These results may help to provide insight into how to improve the CXL outcome in patients afflicted with a severe corneal thinning disease.

  12. Estimating thyroid dose in pediatric CT exams from surface dose measurement

    NASA Astrophysics Data System (ADS)

    Al-Senan, Rani; Mueller, Deborah L.; Hatab, Mustapha R.

    2012-07-01

    The purpose of this study was to investigate the possibility of estimating pediatric thyroid doses from CT using surface neck doses. Optically stimulated luminescence dosimeters were used to measure the neck surface dose of 25 children ranging in ages between one and three years old. The neck circumference for each child was measured. The relationship between obtained surface doses and thyroid dose was studied using acrylic phantoms of various sizes and with holes of different depths. The ratios of hole-to-surface doses were used to convert patients' surface dose to thyroid dose. ImPACT software was utilized to calculate thyroid dose after applying the appropriate age correction factors. A paired t-test was performed to compare thyroid doses from our approach and ImPACT. The ratio of thyroid to surface dose was found to be 1.1. Thyroid doses ranged from 20 to 80 mGy. Comparison showed no statistical significance (p = 0.18). In addition, the average of surface dose variation along the z-axis in helical scans was studied and found to range between 5% (in 10 cm diameter phantom/24 mm collimation/pitch 1.0) and 8% (in 16 cm diameter phantom/12 mm collimation/pitch 0.7). We conclude that surface dose is an acceptable predictor for pediatric thyroid dose from CT. The uncertainty due to surface dose variability may be reduced if narrower collimation is used with a pitch factor close to 1.0. Also, the results did not show any effect of thyroid depth on the measured dose.

  13. Individual external doses below the lowest reference level of 1 mSv per year five years after the 2011 Fukushima nuclear accident among all children in Soma City, Fukushima: A retrospective observational study

    PubMed Central

    Murakami, Michio; Nomura, Shuhei; Morita, Tomohiro; Nishikawa, Yoshitaka; Leppold, Claire; Kato, Shigeaki; Kami, Masahiro

    2017-01-01

    After the 2011 Fukushima Daiichi nuclear power plant accident, little information has been available on individual doses from external exposure among residents living in radioactively contaminated areas near the nuclear plant; in the present study we evaluated yearly changes in the doses from external exposure after the accident and the effects of decontamination on external exposure. This study considered all children less than 16 years of age in Soma City, Fukushima who participated in annual voluntary external exposure screening programs during the five years after the accident (n = 5,363). In total, 14,405 screening results were collected. The median participant age was eight years. The geometric mean levels of annual additional doses from external exposure attributable to the Fukushima accident, decreased each year: 0.60 mSv (range: not detectable (ND)–4.29 mSv), 0.37 mSv (range: ND–3.61 mSv), 0.22 mSv (range: ND–1.44 mSv), 0.20 mSv (range: ND–1.87 mSv), and 0.17 mSv (range: ND–0.85 mSv) in 2011, 2012, 2013, 2014, and 2015, respectively. The proportion of residents with annual additional doses from external exposure of more than 1 mSv dropped from 15.6% in 2011 to zero in 2015. Doses from external exposure decreased more rapidly than those estimated from only physical decay, even in areas without decontamination (which were halved in 395 days from November 15, 2011), presumably due to the weathering effects. While the ratios of geometric mean doses immediately after decontamination to before were slightly lower than those during the same time in areas without decontamination, annual additional doses reduced by decontamination were small (0.04–0.24 mSv in the year of immediately after decontamination was completed). The results of this study showed that the levels of external exposure among Soma residents less than 16 years of age decreased during the five years after the Fukushima Daiichi nuclear power plant accident. Decontamination had only limited and temporal effects on reducing individual external doses. PMID:28235009

  14. Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique.

    PubMed

    Gandhi, Diksha; Crotty, Dominic J; Stevens, Grant M; Schmidt, Taly Gilat

    2015-11-01

    This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings. Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%-20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.

  15. Estimation of annual occupational effective doses from external ionizing radiation at medical institutions in Kenya

    NASA Astrophysics Data System (ADS)

    Korir, Geoffrey; Wambani, Jeska; Korir, Ian

    2011-04-01

    This study details the distribution and trends of doses due to occupational radiation exposure among radiation workers from participating medical institutions in Kenya, where monthly dose measurements were collected for a period of one year ranging from January to December in 2007. A total of 367 medical radiation workers were monitored using thermoluminescent dosemeters. They included radiologists (27%), oncologists (2%), dentists (4%), Physicists (5%), technologists (45%), nurses (4%), film processor technicians (3%), auxiliary staff (4%), and radiology office staff (5%). The average annual effective dose of all categories of staff was found to range from 1.19 to 2.52 mSv. This study formed the initiation stage of wider, comprehensive and more frequent monitoring of occupational radiation exposures and long-term investigations into its accumulation patterns in our country.

  16. Effect of ispronicline, a neuronal nicotinic acetylcholine receptor partial agonist, in subjects with age associated memory impairment (AAMI).

    PubMed

    Dunbar, Geoffrey C; Inglis, Fraser; Kuchibhatla, Ramana; Sharma, Tonmoy; Tomlinson, Mark; Wamsley, James

    2007-03-01

    Cognitive decline seen in the normal elderly is associated with selective loss of neuronal nicotinic acetylcholine receptors (nAChRs). Nicotine given either by inhalation or transdermally helps cognition, but unacceptable side effects limit its utility. The present study assessed the safety, tolerability and effect on cognition of ispronicline, a highly selective partial agonist at the 4beta2 nAChR, in elderly subjects (n =76) with age associated memory impairment (AAMI). This double-blind, placebo-controlled cross-over study explored ascending oral doses of ispronicline in the range 50-150 mg given as a single morning dose for a period of 3 weeks. Pharmacokinetics (PK) were assessed, as well as cognitive function measured by means of the Cognitive Drug Research (CDR) computerized test battery. Ispronicline had a favourable safety profile and was well tolerated at doses below 150 mg. No effect of clinical importance was seen on biochemistry, haematology, urine analysis, vital signs, electrocardiogram (ECG) or Holter monitoring. The most frequent drug induced adverse event was light-headedness (dizziness). A beneficial effect was seen on cognition across the dose range. This was most marked at 50 mg on factors measuring attention and episodic memory. PK analysis indicated a plasma Cmax range of 5-25/35 ng/ml ispronicline was associated with the most beneficial effect. These early results demonstrate ispronicline was well tolerated and did not display the side effects typical of nicotine. Ispronicline also had a beneficial effect on cognition in subjects with AAMI. This was seen most strongly in a Cmax range that had been predicted from pre-clinical animal studies.

  17. Measurement of 131I activity in thyroid of nuclear medical staff and internal dose assessment in a Polish nuclear medical hospital.

    PubMed

    Brudecki, K; Kowalska, A; Zagrodzki, P; Szczodry, A; Mroz, T; Janowski, P; Mietelski, J W

    2017-03-01

    This paper presents results of 131 I thyroid activity measurements in 30 members of the nuclear medicine personnel of the Department of Endocrinology and Nuclear Medicine Holy Cross Cancer Centre in Kielce, Poland. A whole-body spectrometer equipped with two semiconductor gamma radiation detectors served as the basic research instrument. In ten out of 30 examined staff members, the determined 131 I activity was found to be above the detection limit (DL = 5 Bq of 131 I in the thyroid). The measured activities ranged from (5 ± 2) Bq to (217 ± 56) Bq. The highest activities in thyroids were detected for technical and cleaning personnel, whereas the lowest values were recorded for medical doctors. Having measured the activities, an attempt has been made to estimate the corresponding annual effective doses, which were found to range from 0.02 to 0.8 mSv. The highest annual equivalent doses have been found for thyroid, ranging from 0.4 to 15.4 mSv, detected for a cleaner and a technician, respectively. The maximum estimated effective dose corresponds to 32% of the annual background dose in Poland, and to circa 4% of the annual limit for the effective dose due to occupational exposure of 20 mSv per year, which is in compliance with the value recommended by the International Commission on Radiological Protection.

  18. [Hydroxymethyluracil in the correction of adverse effects caused by chemotherapy of malignant neoplasms].

    PubMed

    Sakaeva, D D

    2004-01-01

    Hydroxymethyluracil (HMU) in a dose of 1.5-3 g/day produces a stimulant effect upon leukopoiesis and granulocytopoiesis in cases of toxic neutropenia caused by chemotherapy. In the same dose range, HMU produces immunostimulant action in patients with immune deficit caused by oncopathology and chemotherapy.

  19. Proton dose distribution measurements using a MOSFET detector with a simple dose-weighted correction method for LET effects.

    PubMed

    Kohno, Ryosuke; Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-04-04

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth-dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high-bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L-shaped bolus. The dose reproducibility, angular dependence and depth-dose response were evaluated using a 190 MeV proton beam. Depth-output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose-weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L-shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors.

  20. Dose rate effect of pulsed electron beam on micronucleus frequency in human peripheral blood lymphocytes.

    PubMed

    Acharya, Santhosh; Sanjeev, Ganesh; Bhat, Nagesh N; Narayana, Yerol

    2010-03-01

    The micronucleus assay in human peripheral blood lymphocytes is a sensitive indicator of radiation damage and could serve as a biological dosimeter in evaluating suspected overexposure to ionising radiation. Micronucleus (MN) frequency as a measure of chromosomal damage has also extensively been employed to quantify the effects of radiation dose rate on biological systems. Here we studied the effects of 8 MeV pulsed electron beam emitted by Microtron electron accelerator on MN induction at dose rates between 35 Gy min-1 and 352.5 Gy min-1. These dose rates were achieved by varying the pulse repetition rate (PRR). Fricke dosimeter was employed to measure the absorbed dose at different PRR and to ensure uniform dose distribution of the electron beam. To study the dose rate effect, blood samples were irradiated to an absorbed dose of (4.7+/-0.2) Gy at different rates and cytogenetic damage was quantified using the micronucleus assay. The obtained MN frequency showed no dose rate dependence within the studied dose rate range. Our earlier dose effect study using 8 MeV electrons revealed that the response of MN was linear-quadratic. Therefore, in the event of an accident, dose estimation can be made using linear-quadratic dose response parameters, without adding dose rate as a correction factor.

  1. Ketamine PCA for treatment of end-of-life neuropathic pain in pediatrics.

    PubMed

    Taylor, Matthew; Jakacki, Regina; May, Carol; Howrie, Denise; Maurer, Scott

    2015-12-01

    Control of neuropathic pain (NP) for children at end of life is challenging. Ketamine improves control of NP, but its use in children is not well described. We describe a retrospective case review of 14 children with terminal prognoses treated with ketamine patient-controlled analgesia (PCA) for management of opioid-refractory NP at the end of life. Median ketamine dose was 0.06 mg/kg/h (range 0.014-0.308 mg/kg/h) with a 0.05 mg/kg (range 0.03-0.5mg/kg) demand dose available every 15 minutes (range 10-60 minutes). All patients noted subjective pain relief with ketamine, and 79% had no adverse effects. Benzodiazepines limited neuropsychiatric side effects. Ketamine treatment arrested dose escalation of opioids in 64% of patients, and 79% were discharged to home hospice. Ketamine PCA is an effective, well-tolerated therapy for opioid-refractory NP in pediatric end-of-life care. © The Author(s) 2014.

  2. Radiation Dose to the Lens of the Eye from Computed Tomography Scans of the Head

    NASA Astrophysics Data System (ADS)

    Januzis, Natalie Ann

    While it is well known that exposure to radiation can result in cataract formation, questions still remain about the presence of a dose threshold in radiation cataractogenesis. Since the exposure history from diagnostic CT exams is well documented in a patient's medical record, the population of patients chronically exposed to radiation from head CT exams may be an interesting area to explore for further research in this area. However, there are some challenges in estimating lens dose from head CT exams. An accurate lens dosimetry model would have to account for differences in imaging protocols, differences in head size, and the use of any dose reduction methods. The overall objective of this dissertation was to develop a comprehensive method to estimate radiation dose to the lens of the eye for patients receiving CT scans of the head. This research is comprised of a physics component, in which a lens dosimetry model was derived for head CT, and a clinical component, which involved the application of that dosimetry model to patient data. The physics component includes experiments related to the physical measurement of the radiation dose to the lens by various types of dosimeters placed within anthropomorphic phantoms. These dosimeters include high-sensitivity MOSFETs, TLDs, and radiochromic film. The six anthropomorphic phantoms used in these experiments range in age from newborn to adult. First, the lens dose from five clinically relevant head CT protocols was measured in the anthropomorphic phantoms with MOSFET dosimeters on two state-of-the-art CT scanners. The volume CT dose index (CTDIvol), which is a standard CT output index, was compared to the measured lens doses. Phantom age-specific CTDIvol-to-lens dose conversion factors were derived using linear regression analysis. Since head size can vary among individuals of the same age, a method was derived to estimate the CTDIvol-to-lens dose conversion factor using the effective head diameter. These conversion factors were derived for each scanner individually, but also were derived with the combined data from the two scanners as a means to investigate the feasibility of a scanner-independent method. Using the scanner-independent method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter, most of the fitted lens dose values fell within 10-15% of the measured values from the phantom study, suggesting that this is a fairly accurate method of estimating lens dose from the CTDIvol with knowledge of the patient's head size. Second, the dose reduction potential of organ-based tube current modulation (OB-TCM) and its effect on the CTDIvol-to-lens dose estimation method was investigated. The lens dose was measured with MOSFET dosimeters placed within the same six anthropomorphic phantoms. The phantoms were scanned with the five clinical head CT protocols with OB-TCM enabled on the one scanner model at our institution equipped with this software. The average decrease in lens dose with OB-TCM ranged from 13.5 to 26.0%. Using the size-specific method to derive the CTDIvol-to-lens dose conversion factor from the effective head diameter for protocols with OB-TCM, the majority of the fitted lens dose values fell within 15-18% of the measured values from the phantom study. Third, the effect of gantry angulation on lens dose was investigated by measuring the lens dose with TLDs placed within the six anthropomorphic phantoms. The 2-dimensional spatial distribution of dose within the areas of the phantoms containing the orbit was measured with radiochromic film. A method was derived to determine the CTDIvol-to-lens dose conversion factor based upon distance from the primary beam scan range to the lens. The average dose to the lens region decreased substantially for almost all the phantoms (ranging from 67 to 92%) when the orbit was exposed to scattered radiation compared to the primary beam. The effectiveness of this method to reduce lens dose is highly dependent upon the shape and size of the head, which influences whether or not the angled scan range coverage can include the entire brain volume and still avoid the orbit. The clinical component of this dissertation involved performing retrospective patient studies in the pediatric and adult populations, and reconstructing the lens doses from head CT examinations with the methods derived in the physics component. The cumulative lens doses in the patients selected for the retrospective study ranged from 40 to 1020 mGy in the pediatric group, and 53 to 2900 mGy in the adult group. This dissertation represents a comprehensive approach to lens of the eye dosimetry in CT imaging of the head. The collected data and derived formulas can be used in future studies on radiation-induced cataracts from repeated CT imaging of the head. Additionally, it can be used in the areas of personalized patient dose management, and protocol optimization and clinician training.

  3. Accuracy and Radiation Dose Reduction of Limited-Range CT in the Evaluation of Acute Appendicitis in Pediatric Patients.

    PubMed

    Jin, Michael; Sanchez, Thomas R; Lamba, Ramit; Fananapazir, Ghaneh; Corwin, Michael T

    2017-09-01

    The purpose of this article is to determine the accuracy and radiation dose reduction of limited-range CT prescribed from the top of L2 to the top of the pubic symphysis in children with suspected acute appendicitis. We performed a retrospective study of 210 consecutive pediatric patients from December 11, 2012, through December 11, 2014, who underwent abdominopelvic CT for suspected acute appendicitis. Two radiologists independently reviewed the theoretic limited scans from the superior L2 vertebral body to the top of the pubic symphysis, to assess for visualization of the appendix, acute appendicitis, alternative diagnoses, and incidental findings. Separately, the same parameters were assessed on the full scan by the same two reviewers. Whole-body effective doses were determined for the full- and limited-range scans and were compared using the paired t test. The appendix or entire cecum was visualized on the limited scan in all cases, and no cases of acute appendicitis were missed on the simulated limited scan compared with the full scan. Two alternative diagnoses were missed with the limited scan: one case of hydronephrosis and one of acute acalculous cholecystitis. The mean effective dose for the original scan was 5.6 mSv and that for the simulated limited scan was 3.0 mSv, resulting in a dose reduction of 46.4% (p < 0.001). A limited-range CT examination performed from the top of L2 to the top of the pubic symphysis is as accurate as a full-range abdominopelvic CT in evaluating pediatric patients with suspected appendicitis and reduces the dose by approximately 46%.

  4. Radiation Dose Index of Renal Colic Protocol CT Studies in the United States

    PubMed Central

    Lukasiewicz, Adam; Bhargavan-Chatfield, Mythreyi; Coombs, Laura; Ghita, Monica; Weinreb, Jeffrey; Gunabushanam, Gowthaman; Moore, Christopher L.

    2016-01-01

    Purpose To determine radiation dose indexes for computed tomography (CT) performed with renal colic protocols in the United States, including frequency of reduced-dose technique usage and any institutional-level factors associated with high or low dose indexes. Materials and Methods The Dose Imaging Registry (DIR) collects deidentified CT data, including examination type and dose indexes, for CT performed at participating institutions; thus, the DIR portion of the study was exempt from institutional review board approval and was HIPAA compliant. CT dose indexes were examined at the institutional level for CT performed with a renal colic protocol at institutions that contributed at least 10 studies to the registry as of January 2013. Additionally, patients undergoing CT for renal colic at a single institution (with institutional review board approval and informed consent from prospective subjects and waiver of consent from retrospective subjects) were studied to examine individual renal colic CT dose index patterns and explore relationships between patient habitus, demographics, and dose indexes. Descriptive statistics were used to analyze dose indexes, and linear regression and Spearman correlations were used to examine relationships between dose indexes and institutional factors. Results There were 49 903 renal colic protocol CT examinations conducted at 93 institutions between May 2011 and January 2013. Mean age ± standard deviation was 49 years ± 18, and 53.9% of patients were female. Institutions contributed a median of 268 (interquartile range, 77–699) CT studies. Overall mean institutional dose-length product (DLP) was 746 mGy · cm (effective dose, 11.2 mSv), with a range of 307–1497 mGy · cm (effective dose, 4.6–22.5 mSv) for mean DLPs. Only 2% of studies were conducted with a DLP of 200 mGy · cm or lower (a “reduced dose”) (effective dose, 3 mSv), and only 10% of institutions kept DLP at 400 mGy · cm (effective dose, 6 mSv) or less in at least 50% of patients. Conclusion Reduced-dose renal protocol CT is used infrequently in the United States. Mean dose index is higher than reported previously, and institutional variation is substantial. PMID:24484064

  5. Escalating doses of transdermal nicotine in heavy smokers: effects on smoking behavior and craving.

    PubMed

    Selby, Peter; Andriash, Katherine; Zawertailo, Laurie; Persad, Desmond; Zack, Martin; Busto, Usoa E

    2013-10-01

    Fixed-dose nicotine replacement therapy (NRT) is efficacious for smoking cessation in the general population of smokers. However, it is less effective in populations with psychiatric comorbidities and/or severe tobacco dependence where the percent nicotine replacement is suboptimal. The objective of this pilot study was to determine the effectiveness of nicotine patch dose titration in response to continued smoking in heavily dependent smokers with psychiatric comorbidity. In a single-arm, open-label study adult smokers (mean cigarettes per day, 25.4 ± 13.4; range, 14-43; n = 12) willing to quit were treated with escalating doses of transdermal nicotine and brief counseling intervention if they continued to smoke over a 9-week treatment period. Plasma nicotine and cotinine, along with expired carbon monoxide levels, and the subjective effects of smoking, urge to smoke, demand elasticity, and mood symptoms were also assessed. The mean NRT dose was 32.7 (SD, 16.4) mg/d (range, 7-56 mg/d). Smokers reported significant reductions in both cigarettes per day (mean decrease, 18.4 ± 11.5) confirmed by expired carbon monoxide (mean decrease, 13.5 ± 13.0) with no significant changes in plasma nicotine concentrations during the course of NRT dose titration. There were significant effects on the subjective effects of smoking and measures of smoking behavior. Most commonly reported adverse events were respiratory infections, skin irritation at patch site, nausea, and sleep disturbances, which were generally mild and transient. Titrating doses of NRT to effect with brief intervention hold promise as an effective clinical strategy to assist heavily dependent psychiatrically ill smokers to change their smoking behavior.

  6. Radiotherapy dose verification on a customised head and neck perspex phantom

    NASA Astrophysics Data System (ADS)

    Eng, K. Y.; Kandaiya, S.; Yahaya, N. Z.

    2017-05-01

    IMRT dose planned for head and neck radiotherapy was verified using a customised acrylic head-and-neck phantom. The dosimeters used were calibrated Gafchromic EBT2 film and metal-oxide-semiconductor-field-effect-transistor (MOSFET). Target volumes (TV) and organs-at-risk (OAR) which were previously contoured by an oncologist on selected nasopharynx (NPC) patients were transferred to this phantom by an image fusion procedure. Three radiotherapy plans were done: Plan1 with 7-fields intensity-modulated radiotherapy (IMRT) of prescribed dose 70 Gy using 33 fractions; Plan2 with 7-fields IMRT plan at 70 Gy and 35 fractions; and Plan3 which was a mid-plane-dose (MPD) plan of 66 Gy at 33 fractions. The dose maps were first verified using MapCheck2 by SNC-PatientTM software. The passing rates from gamma analysis were 97.7% (Plan1), 93.1% (Plan2) and 100% (Plan3). Percentage difference between Treatment Planning System (TPS) calculated dose and MOSFET measured dose was comparatively higher than those from EBT2. Calculated dose and EBT2 measured doses showed differences of within the range of ±3% for TV and <±10% for OARs. However MOSFET had differences of within the range of ±6% for TV and within the range of ±10% for OARs between measured and planned doses. An overdose treatment may occur as TPS calculated doses were lower than the measured doses in these plans. This may be due to the effects of leaf leakage, leaf scatter and photon backscatter into the measuring tools (Pawlicki et al., 1999 and Ma et al., 2000). More IMRT plans have to be studied to validate this conclusion. However, the dose measurements were still within the 10% tolerance (AAPM Task Group 119). In conclusion, both GafchromicEBT2 film and MOSFET are suitable for IMRT radiotherapy dosimetry.

  7. Micronucleus induction in Vicia faba roots. Part 2. Biological effects of neutrons below 1 cGy.

    PubMed

    Marshall, I; Bianchi, M

    1983-08-01

    A dose-effect relationship has been established for high-energy neutrons (maximum energy 600 MeV) within a dose range of 0.2 to 80 cGy and for low-energy neutrons produced by a 252Cf source (mean energy 2.35 MeV) for doses between 0.2 and 5 cGy. The frequency of micronuclei was found to increase linearly with dose. The relative biological effectiveness (r.b.e) values calculated using 60Co radiation as a reference were, in the high-dose region, 4.7 +/- 0.4 and 11.8 +/- 1.3 for the high- and low-energy neutrons, respectively. At doses below 1 cGy constant values of 25.4 +/- 4.4 and 63.7 +/- 12 were reached for the respective neutron energies.

  8. Effective Dose of CT- and Fluoroscopy-Guided Perineural/Epidural Injections of the Lumbar Spine: A Comparative Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schmid, Gebhard; Schmitz, Alexander; Borchardt, Dieter

    The objective of this study was to compare the effective radiation dose of perineural and epidural injections of the lumbar spine under computed tomography (CT) or fluoroscopic guidance with respect to dose-reduced protocols. We assessed the radiation dose with an Alderson Rando phantom at the lumbar segment L4/5 using 29 thermoluminescence dosimeters. Based on our clinical experience, 4-10 CT scans and 1-min fluoroscopy are appropriate. Effective doses were calculated for CT for a routine lumbar spine protocol and for maximum dose reduction; as well as for fluoroscopy in a continuous and a pulsed mode (3-15 pulses/s). Effective doses under CTmore » guidance were 1.51 mSv for 4 scans and 3.53 mSv for 10 scans using a standard protocol and 0.22 mSv and 0.43 mSv for the low-dose protocol. In continuous mode, the effective doses ranged from 0.43 to 1.25 mSv for 1-3 min of fluoroscopy. Using 1 min of pulsed fluoroscopy, the effective dose was less than 0.1 mSv for 3 pulses/s. A consequent low-dose CT protocol reduces the effective dose compared to a standard lumbar spine protocol by more than 85%. The latter dose might be expected when applying about 1 min of continuous fluoroscopy for guidance. A pulsed mode further reduces the effective dose of fluoroscopy by 80-90%.« less

  9. On the radiation induced degradation of NBR-EPDM rubbers

    NASA Astrophysics Data System (ADS)

    Chipara, M. D.; Grecu, V. V.; Chipara, M. I.; Ponta, C.; Reyes Romero, J.

    1999-05-01

    The modification of the elongation at break for NBR-EPDM rubbers subjected to gamma irradiation at various integral doses ranging from 10 to 200 kGy, at different dose rates (0.14, 0.47, 1, 3, 4.7 kGy/h) are reported. The presence of the dose rate effect is noticed.

  10. Feasibility of online IMPT adaptation using fast, automatic and robust dose restoration

    NASA Astrophysics Data System (ADS)

    Bernatowicz, Kinga; Geets, Xavier; Barragan, Ana; Janssens, Guillaume; Souris, Kevin; Sterpin, Edmond

    2018-04-01

    Intensity-modulated proton therapy (IMPT) offers excellent dose conformity and healthy tissue sparing, but it can be substantially compromised in the presence of anatomical changes. A major dosimetric effect is caused by density changes, which alter the planned proton range in the patient. Three different methods, which automatically restore an IMPT plan dose on a daily CT image were implemented and compared: (1) simple dose restoration (DR) using optimization objectives of the initial plan, (2) voxel-wise dose restoration (vDR), and (3) isodose volume dose restoration (iDR). Dose restorations were calculated for three different clinical cases, selected to test different capabilities of the restoration methods: large range adaptation, complex dose distributions and robust re-optimization. All dose restorations were obtained in less than 5 min, without manual adjustments of the optimization settings. The evaluation of initial plans on repeated CTs showed large dose distortions, which were substantially reduced after restoration. In general, all dose restoration methods improved DVH-based scores in propagated target volumes and OARs. Analysis of local dose differences showed that, although all dose restorations performed similarly in high dose regions, iDR restored the initial dose with higher precision and accuracy in the whole patient anatomy. Median dose errors decreased from 13.55 Gy in distorted plan to 9.75 Gy (vDR), 6.2 Gy (DR) and 4.3 Gy (iDR). High quality dose restoration is essential to minimize or eventually by-pass the physician approval of the restored plan, as long as dose stability can be assumed. Motion (as well as setup and range uncertainties) can be taken into account by including robust optimization in the dose restoration. Restoring clinically-approved dose distribution on repeated CTs does not require new ROI segmentation and is compatible with an online adaptive workflow.

  11. Radon activity concentrations and effective doses in ancient Egyptian tombs of the Valley of the Kings.

    PubMed

    Hafez, A F; Hussein, A S

    2001-09-01

    Radon concentrations and equilibrium factors were measured in three pharaonic tombs during the year 1998. The tombs, which are open to the public are located in a limestone wadi on the West Bank of the River Nile at Luxor, 650 km south of Cairo. The radon activity concentration and equilibrium factor were measured monthly by two-integral nuclear track detectors (bare and diffusion detectors). Seasonal variation of radon concentrations, with summer maximum and winter minimum were observed in all tombs investigated. The yearly mean radon activity concentrations insidc the tombs ranged from 540 to 3115 Bq m(-3). The mean equilibrium factor over a year was found to be 0.25 and 0.32 inside and at the entrance, respectively. Estimated annual effective doses to tour guides ranged from 0.33 to 1.90 mSv, visitors receive doses from 0.65 to 3.80 microSv per visit. The effective dose to tomb workers did not exceed the 20 mSv yr(-1) limit.

  12. A dose-volume analysis of magnetic resonance imaging-aided high-dose-rate image-based interstitial brachytherapy for uterine cervical cancer.

    PubMed

    Yoshida, Ken; Yamazaki, Hideya; Takenaka, Tadashi; Kotsuma, Tadayuki; Yoshida, Mineo; Furuya, Seiichi; Tanaka, Eiichi; Uegaki, Tadaaki; Kuriyama, Keiko; Matsumoto, Hisanobu; Yamada, Shigetoshi; Ban, Chiaki

    2010-07-01

    To investigate the feasibility of our novel image-based high-dose-rate interstitial brachytherapy (HDR-ISBT) for uterine cervical cancer, we evaluated the dose-volume histogram (DVH) according to the recommendations of the Gynecological GEC-ESTRO Working Group for image-based intracavitary brachytherapy (ICBT). Between June 2005 and June 2007, 18 previously untreated cervical cancer patients were enrolled. We implanted magnetic resonance imaging (MRI)-available plastic applicators by our unique ambulatory technique. Total treatment doses were 30-36 Gy (6 Gy per fraction) combined with external beam radiotherapy (EBRT). Treatment plans were created based on planning computed tomography with MRI as a reference. DVHs of the high-risk clinical target volume (HR CTV), intermediate-risk CTV (IR CTV), and the bladder and rectum were calculated. Dose values were biologically normalized to equivalent doses in 2-Gy fractions (EQD(2)). The median D90 (HR CTV) and D90 (IR CTV) per fraction were 6.8 Gy (range, 5.5-7.5) and 5.4 Gy (range, 4.2-6.3), respectively. The median V100 (HR CTV) and V100 (IR CTV) were 98.4% (range, 83-100) and 81.8% (range, 64-93.8), respectively. When the dose of EBRT was added, the median D90 and D100 of HR CTV were 80.6 Gy (range, 65.5-96.6) and 62.4 Gy (range, 49-83.2). The D(2cc) of the bladder was 62 Gy (range, 51.4-89) and of the rectum was 65.9 Gy (range, 48.9-76). Although the targets were advanced and difficult to treat effectively by ICBT, MRI-aided image-based ISBT showed favorable results for CTV and organs at risk compared with previously reported image-based ICBT results. (c) 2010 Elsevier Inc. All rights reserved.

  13. Dose Equivalents for Second-Generation Antipsychotic Drugs: The Classical Mean Dose Method

    PubMed Central

    Leucht, Stefan; Samara, Myrto; Heres, Stephan; Patel, Maxine X.; Furukawa, Toshi; Cipriani, Andrea; Geddes, John; Davis, John M.

    2015-01-01

    Background: The concept of dose equivalence is important for many purposes. The classical approach published by Davis in 1974 subsequently dominated textbooks for several decades. It was based on the assumption that the mean doses found in flexible-dose trials reflect the average optimum dose which can be used for the calculation of dose equivalence. We are the first to apply the method to second-generation antipsychotics. Methods: We searched for randomized, double-blind, flexible-dose trials in acutely ill patients with schizophrenia that examined 13 oral second-generation antipsychotics, haloperidol, and chlorpromazine (last search June 2014). We calculated the mean doses of each drug weighted by sample size and divided them by the weighted mean olanzapine dose to obtain olanzapine equivalents. Results: We included 75 studies with 16 555 participants. The doses equivalent to 1 mg/d olanzapine were: amisulpride 38.3 mg/d, aripiprazole 1.4 mg/d, asenapine 0.9 mg/d, chlorpromazine 38.9 mg/d, clozapine 30.6 mg/d, haloperidol 0.7 mg/d, quetiapine 32.3mg/d, risperidone 0.4mg/d, sertindole 1.1 mg/d, ziprasidone 7.9 mg/d, zotepine 13.2 mg/d. For iloperidone, lurasidone, and paliperidone no data were available. Conclusions: The classical mean dose method is not reliant on the limited availability of fixed-dose data at the lower end of the effective dose range, which is the major limitation of “minimum effective dose methods” and “dose-response curve methods.” In contrast, the mean doses found by the current approach may have in part depended on the dose ranges chosen for the original trials. Ultimate conclusions on dose equivalence of antipsychotics will need to be based on a review of various methods. PMID:25841041

  14. Lifetime Effective Dose Assessment Based on Background Outdoor Gamma Exposure in Chihuahua City, Mexico

    PubMed Central

    Luevano-Gurrola, Sergio; Perez-Tapia, Angelica; Pinedo-Alvarez, Carmelo; Carrillo-Flores, Jorge; Montero-Cabrera, Maria Elena; Renteria-Villalobos, Marusia

    2015-01-01

    Determining ionizing radiation in a geographic area serves to assess its effects on a population’s health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the annual effective dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, the annual effective dose and the lifetime cancer risk, 48 sampling points were randomly selected in Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Müller counter. Outdoor gamma dose rates ranged from 113 to 310 nGy·h−1. At the same sites, 48 soil samples were taken to obtain the activity concentrations of 226Ra, 232Th and 40K and to calculate their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Calculated gamma dose rates ranged from 56 to 193 nGy·h−1. Results indicated that the lifetime effective dose of the inhabitants of Chihuahua City is on average 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of the activity concentrations in soil were 52, 73 and 1097 Bq·kg−1, for 226Ra, 232Th and 40K, respectively. From the analysis, the spatial distribution of 232Th, 226Ra and 40K is to the north, to the north-center and to the south of city, respectively. In conclusion, the natural background gamma dose received by the inhabitants of Chihuahua City is high and mainly due to the geological characteristics of the zone. From the radiological point of view, this kind of study allows us to identify the importance of manmade environments, which are often highly variable and difficult to characterize. PMID:26437425

  15. Lifetime Effective Dose Assessment Based on Background Outdoor Gamma Exposure in Chihuahua City, Mexico.

    PubMed

    Luevano-Gurrola, Sergio; Perez-Tapia, Angelica; Pinedo-Alvarez, Carmelo; Carrillo-Flores, Jorge; Montero-Cabrera, Maria Elena; Renteria-Villalobos, Marusia

    2015-09-30

    Determining ionizing radiation in a geographic area serves to assess its effects on a population's health. The aim of this study was to evaluate the spatial distribution of the background environmental outdoor gamma dose rates in Chihuahua City. This study also estimated the annual effective dose and the lifetime cancer risks of the population of this city. To determine the outdoor gamma dose rate in air, the annual effective dose and the lifetime cancer risk, 48 sampling points were randomly selected in Chihuahua City. Outdoor gamma dose rate measurements were carried out by using a Geiger-Müller counter. Outdoor gamma dose rates ranged from 113 to 310 nGy·h(-1). At the same sites, 48 soil samples were taken to obtain the activity concentrations of (226)Ra, (232)Th and (40)K and to calculate their terrestrial gamma dose rates. Radioisotope activity concentrations were determined by gamma spectrometry. Calculated gamma dose rates ranged from 56 to 193 nGy·h(-1). Results indicated that the lifetime effective dose of the inhabitants of Chihuahua City is on average 19.8 mSv, resulting in a lifetime cancer risk of 0.001. In addition, the mean of the activity concentrations in soil were 52, 73 and 1097 Bq·kg(-1), for (226)Ra, (232)Th and (40)K, respectively. From the analysis, the spatial distribution of (232)Th, (226)Ra and (40)K is to the north, to the north-center and to the south of city, respectively. In conclusion, the natural background gamma dose received by the inhabitants of Chihuahua City is high and mainly due to the geological characteristics of the zone. From the radiological point of view, this kind of study allows us to identify the importance of manmade environments, which are often highly variable and difficult to characterize.

  16. Aripiprazole Lauroxil

    PubMed Central

    Hard, Marjie L.; Mills, Richard J.; Sadler, Brian M.; Turncliff, Ryan Z.; Citrome, Leslie

    2017-01-01

    Abstract Background Aripiprazole lauroxil is an extended-release prodrug of aripiprazole for intramuscular injection, approved for schizophrenia treatment. We developed a population pharmacokinetic (PopPK) model to characterize aripiprazole lauroxil PK and evaluate dosing scenarios likely to be encountered in clinical practice. Methods Data from 616 patients with schizophrenia, collected from 5 clinical studies, were used to construct the PopPK model. The model was subsequently used to evaluate various dose levels and frequency and the impact of dosing delay on aripiprazole concentrations. Findings The results of the model indicate that aripiprazole is released into the systemic circulation after 5 to 6 days, and release continues for an additional 36 days. The slow increase in aripiprazole concentration after injection necessitates the coadministration of oral aripiprazole for 21 days with the first injection. Based on the PopPK model simulations, a dosing interval of 882 mg every 6 weeks results in aripiprazole concentrations that fall within the concentration range associated with the efficacious aripiprazole lauroxil dose range (441–882 mg dosed monthly). A 662-mg monthly dose also resulted in aripiprazole concentrations within the efficacious dose range. Aripiprazole lauroxil administration results in prolonged exposure, such that dose delays of 2 to 4 weeks, depending on the dose regimen, do not require oral aripiprazole supplementation upon resumption of dosing. Conclusions This PopPK model and model-based simulations were effective means for evaluating aripiprazole lauroxil dosing regimens and management of missed doses. Such analyses play an important role in determining the use of this long-acting antipsychotic in clinical practice. PMID:28350572

  17. Glucan: Mechanisms Involved in Its Radioprotective Effect

    DTIC Science & Technology

    1987-01-01

    Bethesda, Maryland It has generally been accepted that most biologically derived agents that are radlopro- tective in the hemopoietic-syndrome dose range... agents results from enhanced hemopoietic recov- whose onset, nature, and severity are a functior, of both ery and, subsequently, from enhanced...gastroin- radiation in the hemopoietic-syndrome dose range testinai syndrome, and the cer:tral nervous system syn- [37,39,401. As with other agents

  18. Acute and Chronic Effects of Cocaine on the Spontaneous Behavior of Pigeons

    ERIC Educational Resources Information Center

    Pinkston, Jonathan W.; Branch, Marc N.

    2010-01-01

    The present experiment examined the effects of acute and daily cocaine on spontaneous behavior patterns of pigeons. After determining the acute effects of a range of doses, 9 pigeons were divided into three groups that received one of three doses of cocaine daily, either 1.0, 3.0, or 10.0 mg/kg cocaine. Measures were taken of spontaneous…

  19. Estimation of patient radiation dose from whole body 18F- FDG PET/CT examination in cancer imaging: a preliminary study

    NASA Astrophysics Data System (ADS)

    Mahmud, M. H.; Nordin, A. J.; Saad, F. F. Ahmad; Fattah Azman, A. Z.

    2014-11-01

    This study aims to estimate the radiation effective dose resulting from whole body fluorine-18 flourodeoxyglucose Positron Emission Tomography (18F-FDG PET) scanning as compared to conservative Computed Tomography (CT) techniques in evaluating oncology patients. We reviewed 19 oncology patients who underwent 18F-FDG PET/CT at our centre for cancer staging. Internal and external doses were estimated using radioactivity of injected FDG and volume CT Dose Index (CTDIvol), respectively with employment of the published and modified dose coefficients. The median differences of dose among the conservative CT and PET protocols were determined using Kruskal Wallis test with p < 0.05 considered as significant. The median (interquartile range, IQR) effective doses of non-contrasted CT, contrasted CT and PET scanning protocols were 7.50 (9.35) mSv, 9.76 (3.67) mSv and 6.30 (1.20) mSv, respectively, resulting in the total dose of 21.46 (8.58) mSv. Statistically significant difference was observed in the median effective dose between the three protocols (p < 0.01). The effective doses of whole body 18F-FDG PET technique may be effective the lowest amongst the conventional CT imaging techniques.

  20. Hormesis as a biological hypothesis.

    PubMed Central

    Calabrese, E J; Baldwin, L A

    1998-01-01

    A comprehensive effort was undertaken to identify articles demonstrating chemical hormesis. Nearly 4000 potentially relevant articles were retrieved from preliminary computer database searches by using various key word descriptors and extensive cross-referencing. A priori evaluation criteria were established including study design features (e.g., number of doses, dose range), statistical analysis, and reproducibility of results. Evidence of chemical hormesis was judged to have occurred in approximately 350 of the 4000 studies evaluated. Chemical hormesis was observed in a wide range of taxonomic groups and involved agents representing highly diverse chemical classes, many of potential environmental relevance. Numerous biological end points were assessed; growth responses were the most prevalent, followed by metabolic effects, longevity, reproductive responses, and survival. Hormetic responses were generally observed to be of limited magnitude. The average low-dose maximum stimulation was approximately 50% greater than controls. The hormetic dose-response range was generally limited to about one order of magnitude, with the upper end of the hormetic curve approaching the estimated no observable effect level for the particular end point. Based on the evaluation criteria, high to moderate evidence of hormesis was observed in studies comprised of > 6 doses; with > 3 doses in the hormetic zone. The present analysis suggests that chemical hormesis is a reproducible and relatively common biological phenomenon. A quantitative scheme is presented for future application to the database. PMID:9539030

  1. Effect of fluconazole on fungicidal activity of flucytosine in murine cryptococcal meningitis.

    PubMed Central

    Larsen, R A; Bauer, M; Weiner, J M; Diamond, D M; Leal, M E; Ding, J C; Rinaldi, M G; Graybill, J R

    1996-01-01

    Both animal and in vitro studies have demonstrated that combinations of flucytosine with amphotericin B and with fluconazole have significantly improved activity against cryptococcal meningitis compared with the activity of each drug used alone. However, very few dose levels of these agents have been tested in combination. This study evaluated the efficacy of fluconazole plus flucytosine in a murine model of cryptococcal meningitis over a broad range of dose combinations (fluconazole, 0 to 40 micrograms/g of body weight per day; flucytosine, 0 to 200 micrograms/g/day). Both drugs were dissolved in drinking water, with treatment on days 2 to 11. In this highly reproducible model, fluconazole had a dramatic effect on the fungicidal activity of flucytosine. Flucytosine at dose levels of as much as 200 micrograms/g/day alone or in combination with low doses of fluconazole had minimal fungicidal activity, whereas in combination with fluconazole at 24 to 40 micrograms/g/day, flucytosine showed fungicidal activity in the range of 45 to 65% of the animals treated at doses of 40 to 100 micrograms/g/day. This striking effect of fluconazole is consistent with the results of both in vitro and clinical studies. In the clinic, the use of flucytosine is often limited by severe toxicity, while toxicity is rarely observed with fluconazole. These results suggest that when flucytosine is given with higher doses of fluconazole, the maximum therapeutic effect of the former in the clinic may be observed at dose levels that are far less than the doses commonly employed (150 micrograms/g daily). PMID:8878602

  2. Dependence of pentobarbital kinetics upon the dose of the drug and its pharmacodynamic effects.

    PubMed

    Kozlowski, K H; Szaykowski, A; Danysz, A

    1977-01-01

    Pentobarbital (PB), at dose range of 20--50 mg/kg, displays in rabbits non-linear, dose-dependent kinetics. Pharmacokinetics parameters of drug elimination depend largely upon the dose, while the distribution phase is dose-independent. The rate of disappearance of PB from the central compartment (plasma) decreases with the increase of the dose. The analysis of pharmacodynamic parameters has shown that this dose-dependent retardation of PB elimination is probably caused by an impairment of metabolic processes, resulting from disturbance of the circulatory system. A close correlation has been found between the hypotensive effect of PB and the elimination constant, k13, and also between the hypotensive effect and beta.Vd(extrap), a coefficient proportional to the rate of metabolism of PB [23, 29]. The results indicate the necessity of considering the changes in the functional state of the organism, related to the action of a drug, in pharmacokinetic studies.

  3. Multi-scale simulation of radiation damage accumulation and subsequent hardening in neutron-irradiated α-Fe

    DOE PAGES

    Dunn, Aaron; Dingreville, Remi; Capolungo, Laurent

    2015-11-27

    A hierarchical methodology is introduced to predict the effects of radiation damage and irradiation conditions on the yield stress and internal stress heterogeneity developments in polycrystalline α-Fe. Simulations of defect accumulation under displacement cascade damage conditions are performed using spatially resolved stochastic cluster dynamics. The resulting void and dislocation loop concentrations and average sizes are then input into a crystal plasticity formulation that accounts for the change in critical resolved shear stress due to the presence of radiation induced defects. The simulated polycrystalline tensile tests show a good match to experimental hardening data over a wide range of irradiation doses.more » With this capability, stress heterogeneity development and the effect of dose rate on hardening is investigated. The model predicts increased hardening at higher dose rates for low total doses. By contrast, at doses above 10 –2 dpa when cascade overlap becomes significant, the model does not predict significantly different hardening for different dose rates. In conclusion, the development of such a model enables simulation of radiation damage accumulation and associated hardening without relying on experimental data as an input under a wide range of irradiation conditions such as dose, dose rate, and temperature.« less

  4. THE EFFECTS OF LOW DOSES OF GAMMA RADIATION ON PLANT YIELDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowen, H.J.M.; Cawse, P.A.; Smith, S.R.

    1962-09-01

    the effects of low doses of gamma radiation from Co/sup 60/ were tested on dormant seeds of flax, radish, and cabbage, and on young plants of flax, cabbage, lettuce, ciover, duckweed, and pine. Fresh or dry weights were taken as a measure of yieid at harvest. Only in the case of pine seedlings was significant stimulation noticed: this occurred in the dose range 2 to 6 rad after 9 months growth. (auth)

  5. Tolerance to repeated nicotine administration on performance, subjective, and physiological responses in nonsmokers.

    PubMed

    Heishman, S J; Henningfield, J E

    2000-10-01

    When administered acutely to nonsmokers, nicotine's effects on performance are inconsistent, perhaps because of suboptimal dosing or initial dysphoria that could interfere with performance. The purpose of this study was to determine if a range of nicotine doses administered for 8 days to nonsmokers would enhance psychomotor and cognitive abilities and to document the development of nicotine tolerance or sensitization. Twelve male volunteers, who reported ever smoking five cigarettes or less, participated in 8 consecutive experimental days in which they were administered four doses of nicotine polacrilex gum each day in this order: 0, 2, 4, and 8 mg. Performance, subjective, and physiological measures were assessed before and after each dose. Plasma nicotine concentration ranged from 6.9 to 11.5 ng/ml following the 8 mg dose. Nicotine increased rate of responding and decreased response time on working memory (digit recall); however, accuracy was impaired. Nicotine also decreased accuracy on visual scanning and attention (two-letter search), and the 8 mg dose impaired gross motor coordination (circular lights). Tolerance did not develop to the performance impairing effects of nicotine. Nicotine produced dose-related increases in ratings of dysphoria and negative mood, including tension, anxiety, nervousness, turning of stomach, and sedation. Tolerance developed to some, but not all, of these aversive effects. Tolerance also was not observed to the increased cardiovascular measures. Although tolerance developed to some of the aversive effects of nicotine, performance enhancement was not observed. These data do not support the hypothesis that nicotine-induced performance enhancement contributes to the reinforcing effects of tobacco use during the early stages of dependence development.

  6. Optimizing Radiation Doses for Computed Tomography Across Institutions: Dose Auditing and Best Practices.

    PubMed

    Demb, Joshua; Chu, Philip; Nelson, Thomas; Hall, David; Seibert, Anthony; Lamba, Ramit; Boone, John; Krishnam, Mayil; Cagnon, Christopher; Bostani, Maryam; Gould, Robert; Miglioretti, Diana; Smith-Bindman, Rebecca

    2017-06-01

    Radiation doses for computed tomography (CT) vary substantially across institutions. To assess the impact of institutional-level audit and collaborative efforts to share best practices on CT radiation doses across 5 University of California (UC) medical centers. In this before/after interventional study, we prospectively collected radiation dose metrics on all diagnostic CT examinations performed between October 1, 2013, and December 31, 2014, at 5 medical centers. Using data from January to March (baseline), we created audit reports detailing the distribution of radiation dose metrics for chest, abdomen, and head CT scans. In April, we shared reports with the medical centers and invited radiology professionals from the centers to a 1.5-day in-person meeting to review reports and share best practices. We calculated changes in mean effective dose 12 weeks before and after the audits and meeting, excluding a 12-week implementation period when medical centers could make changes. We compared proportions of examinations exceeding previously published benchmarks at baseline and following the audit and meeting, and calculated changes in proportion of examinations exceeding benchmarks. Of 158 274 diagnostic CT scans performed in the study period, 29 594 CT scans were performed in the 3 months before and 32 839 CT scans were performed 12 to 24 weeks after the audit and meeting. Reductions in mean effective dose were considerable for chest and abdomen. Mean effective dose for chest CT decreased from 13.2 to 10.7 mSv (18.9% reduction; 95% CI, 18.0%-19.8%). Reductions at individual medical centers ranged from 3.8% to 23.5%. The mean effective dose for abdominal CT decreased from 20.0 to 15.0 mSv (25.0% reduction; 95% CI, 24.3%-25.8%). Reductions at individual medical centers ranged from 10.8% to 34.7%. The number of CT scans that had an effective dose measurement that exceeded benchmarks was reduced considerably by 48% and 54% for chest and abdomen, respectively. After the audit and meeting, head CT doses varied less, although some institutions increased and some decreased mean head CT doses and the proportion above benchmarks. Reviewing institutional doses and sharing dose-optimization best practices resulted in lower radiation doses for chest and abdominal CT and more consistent doses for head CT.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moore, B; Brady, S; Kaufman, R

    Purpose: Investigate the correlation of SSDE with organ dose in a pediatric population. Methods: Four anthropomorphic phantoms, representing a range of pediatric body habitus, were scanned with MOSFET dosimeters placed at 23 organ locations to determine absolute organ dosimetry. Phantom organ dosimetry was divided by phantom SSDE to determine correlation between organ dose and SSDE. Correlation factors were then multiplied by patient SSDE to estimate patient organ dose. Patient demographics consisted of 352 chest and 241 abdominopelvic CT examinations, 22 ± 15 kg (range 5−55 kg) mean weight, and 6 ± 5 years (range 4 mon to 23 years) meanmore » age. Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm. 23 organ correlation factors were determined in the chest and abdominopelvic region across nine pediatric weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7−1.4) and abdominopelvic (average 0.9; range 0.7−1.3) was near unity. For organs that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1−0.4) for both the chest and abdominopelvic regions, respectively. Pediatric organ dosimetry was compared to published values and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusion: Average correlation of SSDE and organ dosimetry was found to be better than ± 10% for fully covered organs within the scan volume. This study provides a list of organ dose correlation factors for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE.« less

  8. Proton dose distribution measurements using a MOSFET detector with a simple dose‐weighted correction method for LET effects

    PubMed Central

    Hotta, Kenji; Matsuura, Taeko; Matsubara, Kana; Nishioka, Shie; Nishio, Teiji; Kawashima, Mitsuhiko; Ogino, Takashi

    2011-01-01

    We experimentally evaluated the proton beam dose reproducibility, sensitivity, angular dependence and depth‐dose relationships for a new Metal Oxide Semiconductor Field Effect Transistor (MOSFET) detector. The detector was fabricated with a thinner oxide layer and was operated at high‐bias voltages. In order to accurately measure dose distributions, we developed a practical method for correcting the MOSFET response to proton beams. The detector was tested by examining lateral dose profiles formed by protons passing through an L‐shaped bolus. The dose reproducibility, angular dependence and depth‐dose response were evaluated using a 190 MeV proton beam. Depth‐output curves produced using the MOSFET detectors were compared with results obtained using an ionization chamber (IC). Since accurate measurements of proton dose distribution require correction for LET effects, we developed a simple dose‐weighted correction method. The correction factors were determined as a function of proton penetration depth, or residual range. The residual proton range at each measurement point was calculated using the pencil beam algorithm. Lateral measurements in a phantom were obtained for pristine and SOBP beams. The reproducibility of the MOSFET detector was within 2%, and the angular dependence was less than 9%. The detector exhibited a good response at the Bragg peak (0.74 relative to the IC detector). For dose distributions resulting from protons passing through an L‐shaped bolus, the corrected MOSFET dose agreed well with the IC results. Absolute proton dosimetry can be performed using MOSFET detectors to a precision of about 3% (1 sigma). A thinner oxide layer thickness improved the LET in proton dosimetry. By employing correction methods for LET dependence, it is possible to measure absolute proton dose using MOSFET detectors. PACS number: 87.56.‐v

  9. Estimated ultraviolet radiation doses in wetlands in six national parks

    USGS Publications Warehouse

    Diamond, S.A.; Trenham, P.C.; Adams, Michael J.; Hossack, B.R.; Knapp, R.A.; Stark, L.; Bradford, D.; Corn, P.S.; Czarnowski, K.; Brooks, P.D.; Fagre, D.B.; Breen, B.; Dentenbeck, N.E.; Tonnessen, K.

    2005-01-01

    Ultraviolet-B radiation (UV-B, 280–320-nm wavelengths) doses were estimated for 1024 wetlands in six national parks: Acadia (Acadia), Glacier (Glacier), Great Smoky Mountains (Smoky), Olympic (Olympic), Rocky Mountain (Rocky), and Sequoia/Kings Canyon (Sequoia). Estimates were made using ground-based UV-B data (Brewer spectrophotometers), solar radiation models, GIS tools, field characterization of vegetative features, and quantification of DOC concentration and spectral absorbance. UV-B dose estimates were made for the summer solstice, at a depth of 1 cm in each wetland. The mean dose across all wetlands and parks was 19.3 W-h m−2 (range of 3.4–32.1 W-h m−2). The mean dose was lowest in Acadia (13.7 W-h m−2) and highest in Rocky (24.4 W-h m−2). Doses were significantly different among all parks. These wetland doses correspond to UV-B flux of 125.0 μW cm−2 (range 21.4–194.7 μW cm−2) based on a day length, averaged among all parks, of 15.5 h. Dissolved organic carbon (DOC), a key determinant of water-column UV-B flux, ranged from 0.6 (analytical detection limit) to 36.7 mg C L−1 over all wetlands and parks, and reduced potential maximal UV-B doses at 1-cm depth by 1%–87 %. DOC concentration, as well as its effect on dose, was lowest in Sequoia and highest in Acadia (DOC was equivalent in Acadia, Glacier, and Rocky). Landscape reduction of potential maximal UV-B doses ranged from zero to 77% and was lowest in Sequoia. These regional differences in UV-B wetland dose illustrate the importance of considering all aspects of exposure in evaluating the potential impact of UV-B on aquatic organisms.

  10. Predictors of Local Control After Single-Dose Stereotactic Image-Guided Intensity-Modulated Radiotherapy for Extracranial Metastases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Greco, Carlo; Zelefsky, Michael J., E-mail: zelefskm@mskcc.or; Lovelock, Michael

    2011-03-15

    Purpose: To report tumor local control after treatment with single-dose image-guided intensity-modulated radiotherapy (SD-IGRT) to extracranial metastatic sites. Methods and Materials: A total of 126 metastases in 103 patients were treated with SD-IGRT to prescription doses of 18-24 Gy (median, 24 Gy) between 2004 and 2007. Results: The overall actuarial local relapse-free survival (LRFS) rate was 64% at a median follow-up of 18 months (range, 2-45 months). The median time to failure was 9.6 months (range, 1-23 months). On univariate analysis, LRFS was significantly correlated with prescription dose (p = 0.029). Stratification by dose into high (23 to 24 Gy),more » intermediate (21 to 22 Gy), and low (18 to 20 Gy) dose levels revealed highly significant differences in LRFS between high (82%) and low doses (25%) (p < 0.0001). Overall, histology had no significant effect on LRFS (p = 0.16). Renal cell histology displayed a profound dose-response effect, with 80% LRFS at the high dose level (23 to 24 Gy) vs. 37% with low doses ({<=}22 Gy) (p = 0.04). However, for patients who received the high dose level, histology was not a statistically significant predictor of LRFS (p = 0.90). Target organ (bone vs. lymph node vs. soft tissues) (p = 0.5) and planning target volume size (p = 0.55) were not found to be associated with long-term LRFS probability. Multivariate Cox regression analysis confirmed prescription dose to be a significant predictor of LRFS (p = 0.003). Conclusion: High-dose SD-IGRT is a noninvasive procedure resulting in high probability of local tumor control. Single-dose IGRT may be effectively used to locally control metastatic deposits regardless of histology and target organ, provided sufficiently high doses (> 22 Gy) of radiation are delivered.« less

  11. Dosimetry of {sup 210}Po in humans, caribou, and wolves in northern Canada

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, P.A.

    1994-06-01

    Effective doses from {sup 210}Po intake with caribou meat were determined for human residents in Baker Lake and Snowdrift in the Northwest Territories of Canada and compared to doses calculated from reported {sup 210}Po tissue activities in Alaskan and British residents. Effective doses were calculated to separate body tissues, using ICRP 60 human weighting factors and the ICRP 30 metabolic model for {sup 210}Po. Baker Lake and Alaskan effective doses were similar at 0.4 mSv y{sup {minus}1} and slightly higher than Snowdrift doses (0.3 mSv y{sup {minus}1}). Alaskan tissue activities indicated higher effective doses to liver, bone surfaces and redmore » marrow and lower doses to spleen than the {sup 210}Po metabolic model (ICRP 1979a) predicts. Effective doses to Baker Lake and Snowdrift caribou and wolves, calculated from tissue activities, ranged from 7-20 mSv y{sup {minus}1} using human weighting factors for comparison to human doses only. Effective doses to northern Canadians and wildlife were, respectively, 7-11% and 1.8-5 times an estimated human background of 4 mSv y{sup {minus}} from all sources. 51 refs., 2 figs., 9 tabs.« less

  12. Cumulative effective dose and cancer risk for pediatric population in repetitive full spine follow-up imaging: How micro dose is the EOS microdose protocol?

    PubMed

    Law, Martin; Ma, Wang-Kei; Lau, Damian; Cheung, Kenneth; Ip, Janice; Yip, Lawrance; Lam, Wendy

    2018-04-01

    To evaluate and to obtain analytic formulation for the calculation of the effective dose and associated cancer risk using the EOS microdose protocol for scoliotic pediatric patients undergoing full spine imaging at different age of exposure; to demonstrate the microdose protocol capable of delivering lesser radiation dose and hence of further reducing cancer risk induction when compared with the EOS low dose protocol; to obtain cumulative effective dose and cancer risk for both genders scoliotic pediatrics of US and Hong Kong population using the microdose protocol. Organ absorbed doses of full spine exposed scoliotic pediatric patients have been simulated with the use of EOS microdose protocol imaging parameters input to the Monte Carlo software PCXMC. Gender and age specific effective dose has been calculated with the simulated organ absorbed dose using the ICRP-103 approach. The associated radiation induced cancer risk, expressed as lifetime attributable risk (LAR), has been estimated according to the method introduced in the Biological Effects of Ionizing Radiation VII report. Values of LAR have been estimated for scoliotic patients exposed repetitively during their follow up period at different age for US and Hong Kong population. The effective doses of full spine imaging with simultaneous posteroanterior and lateral projection for patients exposed at the age between 5 and 18 years using the EOS microdose protocol have been calculated within the range of 2.54-14.75 μSv. The corresponding LAR for US and Hong Kong population was ranged between 0.04 × 10 -6 and 0.84 × 10 -6 . Cumulative effective dose and cancer risk during follow-up period can be estimated using the results and are of information to patients and their parents. With the use of computer simulation and analytic formulation, we obtained the cumulative effective dose and cancer risk at any age of exposure for pediatric patients of US and Hong Kong population undergoing repetitive microdose protocol full spine imaging. Girls would be at a statistically significant higher cumulative cancer risk than boys undergoing the same microdose full spine imaging protocol and the same follow-up schedule. Copyright © 2018 Elsevier B.V. All rights reserved.

  13. Technical Note: Phantom study to evaluate the dose and image quality effects of a computed tomography organ-based tube current modulation technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gandhi, Diksha; Schmidt, Taly Gilat, E-mail: taly.gilat-schmidt@marquette.edu; Crotty, Dominic J.

    Purpose: This technical note quantifies the dose and image quality performance of a clinically available organ-dose-based tube current modulation (ODM) technique, using experimental and simulation phantom studies. The investigated ODM implementation reduces the tube current for the anterior source positions, without increasing current for posterior positions, although such an approach was also evaluated for comparison. Methods: Axial CT scans at 120 kV were performed on head and chest phantoms on an ODM-equipped scanner (Optima CT660, GE Healthcare, Chalfont St. Giles, England). Dosimeters quantified dose to breast, lung, heart, spine, eye lens, and brain regions for ODM and 3D-modulation (SmartmA) settings.more » Monte Carlo simulations, validated with experimental data, were performed on 28 voxelized head phantoms and 10 chest phantoms to quantify organ dose and noise standard deviation. The dose and noise effects of increasing the posterior tube current were also investigated. Results: ODM reduced the dose for all experimental dosimeters with respect to SmartmA, with average dose reductions across dosimeters of 31% (breast), 21% (lung), 24% (heart), 6% (spine), 19% (eye lens), and 11% (brain), with similar results for the simulation validation study. In the phantom library study, the average dose reduction across all phantoms was 34% (breast), 20% (lung), 8% (spine), 20% (eye lens), and 8% (brain). ODM increased the noise standard deviation in reconstructed images by 6%–20%, with generally greater noise increases in anterior regions. Increasing the posterior tube current provided similar dose reduction as ODM for breast and eye lens, increased dose to the spine, with noise effects ranging from 2% noise reduction to 16% noise increase. At noise equal to SmartmA, ODM increased the estimated effective dose by 4% and 8% for chest and head scans, respectively. Increasing the posterior tube current further increased the effective dose by 15% (chest) and 18% (head) relative to SmartmA. Conclusions: ODM reduced dose in all experimental and simulation studies over a range of phantoms, while increasing noise. The results suggest a net dose/noise benefit for breast and eye lens for all studied phantoms, negligible lung dose effects for two phantoms, increased lung dose and/or noise for eight phantoms, and increased dose and/or noise for brain and spine for all studied phantoms compared to the reference protocol.« less

  14. Pharmacokinetics of terbinafine after oral administration of a single dose to Hispaniolan Amazon parrots (Amazona ventralis).

    PubMed

    Evans, Erika E; Emery, Lee C; Cox, Sherry K; Souza, Marcy J

    2013-06-01

    To determine pharmacokinetics after oral administration of a single dose of terbinafine hydrochloride to Hispaniolan Amazon parrots (Amazona ventralis). 6 healthy adult Hispaniolan Amazon parrots. A single dose of terbinafine hydrochloride (60 mg/kg) was administered orally to each bird, which was followed immediately by administration of a commercially available gavage feeding formula. Blood samples were collected at the time of drug administration (time 0) and 0.25, 0.5, 1, 2, 4, 8, 12, and 24 hours after drug administration. Plasma concentrations of terbinafine were determined via high-performance liquid chromatography. Data from 1 bird were discarded because of a possible error in the dose of drug administered. After oral administration of terbinafine, the maximum concentration for the remaining 5 fed birds ranged from 109 to 671 ng/mL, half-life ranged from 6 to 13.5 hours, and time to the maximum concentration ranged from 2 to 8 hours. No adverse effects were observed. Analysis of the results indicated that oral administration of terbinafine at a dose of 60 mg/kg to Amazon parrots did not result in adverse effects and may be potentially of use in the treatment of aspergillosis. Additional studies are needed to determine treatment efficacy and safety.

  15. A study of the parameters affecting the effectiveness of Moringa oleifera in drinking water purification

    NASA Astrophysics Data System (ADS)

    Pritchard, M.; Craven, T.; Mkandawire, T.; Edmondson, A. S.; O'Neill, J. G.

    The powder obtained from the seeds of the Moringa oleifera tree has been shown to be an effective primary coagulant for water treatment. When the seeds are dried, dehusked, crushed and added to water, the powder acts as a coagulant binding colloidal particles and bacteria to form agglomerated particles (flocs), which settle allowing the clarified supernatant to be poured off. Very little research has been undertaken on the parameters affecting the effectiveness of M. oleifera, especially in Malawi, for purification of drinking water and there is a great need for further testing in this area. Conclusive data needs to be compiled to demonstrate the effects of various water parameters have on the efficiency of the seeds. A parametric study was undertaken at Leeds Metropolitan University, UK, with the aim to establish the most appropriate dosing method; the optimum dosage for removal of turbidity; the influence of pH and temperature; together with the shelf life of the M. oleifera seeds. The study revealed that the most suitable dosing method was to mix the powder into a concentrated paste, hence forming a stock suspension. The optimum M. oleifera dose, for turbidity values between 40 and 200 NTU, ranged between 30 and 55 mg/l. With turbidity set at 130 NTU and a M. oleifera dose within the optimum range at 50 mg/l, pH levels were varied between 4 and 9. It was discovered that the coagulant performance was not too sensitive to pH fluctuations when conditions were within the optimum range. The most efficient coagulation, determined by the greatest reduction in turbidity, occurred at pH 6.5. Alkaline conditions were overall more favourable than acidic conditions; pH 9 had an efficiency of 65% of optimum, whilst at pH 5 the efficiency dropped to around 55%. The efficiency further dropped at pH 4, where the powder only produced results of around 10% of optimum conditions. A temperature range of 4-60 °C was studied in this research. Colder waters (<15 °C) were found to hinder the effectiveness of the coagulation process. The higher the temperature the more effective was the coagulation. It was also found that the age of the seeds, up to 18 months, did not have any noticeable effect on dose level and percentage reduction in turbidity, although at 18 months the seeds had a narrower dosing range to produce near-optimum reduction. Seeds aged 24 months showed a significant decline in coagulant efficiency.

  16. Testicular toxicity in cannabis extract treated mice: association with oxidative stress and role of antioxidant enzyme systems.

    PubMed

    Mandal, Tapas K; Das, Nildari S

    2010-02-01

    Intraperitoneal injection of cannabis extract at low doses (total doses ranging from 40 mg to 60 mg per mouse) induced adverse effect on testes and oxidative stress. At low doses, there was a significant increase in lipid peroxidation and decrease in testicular lipid content, but the effects were significantly less at higher doses and at the withdrawal of cannabis treatment (recovery dose). There was a marked decrease in antioxidant enzyme profiles (superoxide dismutase, catalase and glutathione peroxidase) and glutathione content at low doses, but these effects were higher at higher dose and at withdrawal of the treatment (recovery effect). Histology revealed significant shrinkage of tubular diameter and detrimental changes in seminiferous epithelium of testis with resulting lowered serum testosterone and pituitary gonadotropins (follicular stimulating [FSH] and luteinizing hormones [LH]) levels at low doses. But at higher doses and particularly at withdrawal of the treatment, regression of various germ cell layers of testes through the revival of testosterone hormone and pituitary gonadotropins (FSH and LH) were observed, indicating that recovery effects on testes became operative possibly through the corrective measure of endogenous testicular antioxidant enzymes profiles and pituitary gonadotropins hormones feedback mechanisms.

  17. Direct cardiac effects of intracoronary bupivacaine, levobupivacaine and ropivacaine in the sheep

    PubMed Central

    Chang, Dennis H-T; Ladd, Leigh A; Copeland, Susan; Iglesias, Miguel A; Plummer, John L; Mather, Laurence E

    2001-01-01

    The racemic local anaesthetic agent bupivacaine is widely used clinically for its long duration of action. Levobupivacaine and ropivacaine are bupivacaine enantiopure congeners, developed to improve upon the clinical safety of bupivacaine, especially the risk of fatal arrhythmogenesis. In previous preclinical studies of the safety of these drugs with intravenous administration in conscious ewes over a wide dose range, we found that central nervous system (CNS) excito-toxicity reversed the cardiac depressant effects when doses approached the convulsant threshold and thus precluded accurate comparison of their cardiovascular system (CVS) effects. To study CVS effects over a wide range of doses with minimal CNS and other influences, brief (3 min) infusions of bupivacaine, levobupivacaine or ropivacaine were administered into the left main coronary arteries of previously instrumented conscious ewes (∼50 Kg body weight). After dose-ranging studies, the drugs were compared in a randomized, blinded, parallel group design. Equimolar doses were increased from 8 μmol (≈amp;2.5 mg) in 8 μmol increments, to either a fatal outcome or a 40 μmol (≈amp;12.5 mg) maximum. All three drugs produced tachycardia, decreased myocardial contractility and stroke volume and widening of electrocardiographic QRS complexes. Thirteen of 19 animals died of ventricular fibrillation: four of six with bupivacaine (mean±s.e.mean actual fatal dose: 21.8±6.4 μmol), five of seven with levobupivacaine (22.9±3.5 μmol), four of six with ropivacaine (22.9±5.9 μmol). No significant differences in survival or in fatal doses between these drugs were found. The findings suggest that ropivacaine, levobupivacaine and bupivacaine have similar intrinsic ability to cause direct fatal cardiac toxicity when administered by left intracoronary arterial infusion in conscious sheep and do not explain the differences between the drugs found with intravenous dosage. PMID:11159717

  18. Oral desmopressin in central diabetes insipidus.

    PubMed Central

    Westgren, U; Wittström, C; Harris, A S

    1986-01-01

    Seven paediatric patients with central diabetes insipidus were studied in an open dose ranging study in hospital followed by a six month study on an outpatient basis to assess the efficacy and safety of peroral administration of DDAVP (desmopressin) tablets. In the dose ranging study a dose dependent antidiuretic response was observed. The response to 12.5-50 mcg was, however, less effective in correcting baseline polyuria than were doses of 100 mcg and above. Patients were discharged from hospital on a preliminary dosage regimen ranging from 100 to 400 mcg three times daily. After an initial adjustment in dosage in three patients at one week follow up, all patients were stabilised on treatment with tablets and reported an adequate water turnover at six months. As with the intranasal route of administration dosage requirements varied from patient to patient, and a dose range rather than standard doses were required. A significant correlation, however, was found for the relation between previous intranasal and present oral daily dosage. No adverse reactions were reported. No clinically significant changes were noted in blood chemistry and urinalysis. All patients expressed a preference for the oral over existing intranasal treatment. Treatment with tablets offers a beneficial alternative to the intranasal route, particularly in patients with chronic rhinitis or impaired vision. PMID:3963868

  19. Effect of processor temperature on film dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Srivastava, Shiv P.; Das, Indra J., E-mail: idas@iupui.edu

    2012-07-01

    Optical density (OD) of a radiographic film plays an important role in radiation dosimetry, which depends on various parameters, including beam energy, depth, field size, film batch, dose, dose rate, air film interface, postexposure processing time, and temperature of the processor. Most of these parameters have been studied for Kodak XV and extended dose range (EDR) films used in radiation oncology. There is very limited information on processor temperature, which is investigated in this study. Multiple XV and EDR films were exposed in the reference condition (d{sub max.}, 10 Multiplication-Sign 10 cm{sup 2}, 100 cm) to a given dose. Anmore » automatic film processor (X-Omat 5000) was used for processing films. The temperature of the processor was adjusted manually with increasing temperature. At each temperature, a set of films was processed to evaluate OD at a given dose. For both films, OD is a linear function of processor temperature in the range of 29.4-40.6 Degree-Sign C (85-105 Degree-Sign F) for various dose ranges. The changes in processor temperature are directly related to the dose by a quadratic function. A simple linear equation is provided for the changes in OD vs. processor temperature, which could be used for correcting dose in radiation dosimetry when film is used.« less

  20. The effective dose of different scanning protocols using the Sirona GALILEOS® comfort CBCT scanner

    PubMed Central

    Bohay, R; Kaci, L; Barnett, R; Battista, J

    2015-01-01

    Objectives: To determine the effective dose and CT dose index (CTDI) for a range of imaging protocols using the Sirona GALILEOS® Comfort CBCT scanner (Sirona Dental Systems GmbH, Bensheim, Germany). Methods: Calibrated optically stimulated luminescence dosemeters were placed at 26 sites in the head and neck of a modified RANDO® phantom (The Phantom Laboratory, Greenwich, NY). Effective dose was calculated for 12 different scanning protocols. CTDI measurements were also performed to determine the dose–length product (DLP) and the ratio of effective dose to DLP for each scanning protocol. Results: The effective dose for a full maxillomandibular scan at 42 mAs was 102 ± 1 μSv and remained unchanged with varying contrast and resolution settings. This compares with 71 μSv for a maxillary scan and 76 μSv for a mandibular scan with identical milliampere-seconds (mAs) at high contrast and resolution settings. Conclusions: Changes to mAs and beam collimation have a significant influence on effective dose. Effective dose and DLP vary linearly with mAs. A collimated maxillary or mandibular scan decreases effective dose by approximately 29% and 24%, respectively, as compared with a full maxillomandibular scan. Changes to contrast and resolution settings have little influence on effective dose. This study provides data for setting individualized patient exposure protocols to minimize patient dose from ionizing radiation used for diagnostic or treatment planning tasks in dentistry. PMID:25358865

  1. Biological Effectiveness of Accelerated Particles for the Induction of Chromosome Damage Measured in Metaphase and Interphase Human Lymphocytes

    NASA Technical Reports Server (NTRS)

    George, Kerry; Durante, Marco; Willingham, Veronica; Wu, Honglu; Yang, Tracy C.; Cucinotta, Francis A.

    2003-01-01

    Chromosome aberrations were investigated in human lymphocytes after in vitro exposure to 1H-, 3He-, 12C-, 40Ar-, 28Si-, 56Fe-, or 197Au-ion beams, with LET ranging from approximately 0.4-1393 keV/microm in the dose range of 0.075-3 Gy. Dose-response curves for chromosome exchanges, measured at the first mitosis postirradiation using fluorescence in situ hybridization (FISH) with whole-chromosome probes, were fitted with linear or linear-quadratic functions. The relative biological effectiveness (RBE) was estimated from the initial slope of the dose-response curve for chromosomal damage with respect to low- or high-dose-rate gamma rays. Estimates of RBEmax values for mitotic spreads, which ranged from near 0.7 to 11.1 for total exchanges, increased with LET, reaching a maximum at about 150 keV/microm, and decreased with further increase in LET. RBEs for complex aberrations are undefined due to the lack of an initial slope for gamma rays. Additionally, the effect of mitotic delay on RBE values was investigated by measuring chromosome aberrations in interphase after chemically induced premature chromosome condensation (PCC), and values were up to threefold higher than for metaphase analysis.

  2. Real-Time Patient and Staff Radiation Dose Monitoring in IR Practice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sailer, Anna M., E-mail: karmanna@stanford.edu; Paulis, Leonie, E-mail: leonie.paulis@mumc.nl; Vergoossen, Laura

    PurposeKnowledge of medical radiation exposure permits application of radiation protection principles. In our center, the first dedicated real-time, automated patient and staff dose monitoring system (DoseWise Portal, Philips Healthcare) was installed. Aim of this study was to obtain insight in the procedural and occupational doses.Materials and MethodsAll interventional radiologists, vascular surgeons, and technicians wore personal dose meters (PDMs, DoseAware, Philips Healthcare). The dose monitoring system simultaneously registered for each procedure dose-related data as the dose area product (DAP) and effective staff dose (E) from PDMs. Use and type of shielding were recorded separately. All procedures were analyzed according to proceduremore » type; these included among others cerebral interventions (n = 112), iliac and/or caval venous recanalization procedures (n = 68), endovascular aortic repair procedures (n = 63), biliary duct interventions (n = 58), and percutaneous gastrostomy procedure (n = 28).ResultsMedian (±IQR) DAP doses ranged from 2.0 (0.8–3.1) (percutaneous gastrostomy) to 84 (53–147) Gy cm{sup 2} (aortic repair procedures). Median (±IQR) first operator doses ranged from 1.6 (1.1–5.0) μSv to 33.4 (12.1–125.0) for these procedures, respectively. The relative exposure, determined as first operator dose normalized to procedural DAP, ranged from 1.9 in biliary interventions to 0.1 μSv/Gy cm{sup 2} in cerebral interventions, indicating large variation in staff dose per unit DAP among the procedure types.ConclusionReal-time dose monitoring was able to identify the types of interventions with either an absolute or relatively high staff dose, and may allow for specific optimization of radiation protection.« less

  3. Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations

    PubMed Central

    Moore, Bria M.; Brady, Samuel L.; Mirro, Amy E.; Kaufman, Robert A.

    2014-01-01

    Purpose: To investigate the correlation of size-specific dose estimate (SSDE) with absorbed organ dose, and to develop a simple methodology for estimating patient organ dose in a pediatric population (5–55 kg). Methods: Four physical anthropomorphic phantoms representing a range of pediatric body habitus were scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations to determine absolute organ dose. Phantom absolute organ dose was divided by phantom SSDE to determine correlation between organ dose and SSDE. Organ dose correlation factors (\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}${\\rm CF}_{{\\rm SSDE}}^{{\\rm organ}}$\\end{document} CF SSDE organ ) were then multiplied by patient-specific SSDE to estimate patient organ dose. The \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}${\\rm CF}_{{\\rm SSDE}}^{{\\rm organ}}$\\end{document} CF SSDE organ were used to retrospectively estimate individual organ doses from 352 chest and 241 abdominopelvic pediatric CT examinations, where mean patient weight was 22 kg ± 15 (range 5–55 kg), and mean patient age was 6 yrs ± 5 (range 4 months to 23 yrs). Patient organ dose estimates were compared to published pediatric Monte Carlo study results. Results: Phantom effective diameters were matched with patient population effective diameters to within 4 cm; thus, showing appropriate scalability of the phantoms across the entire pediatric population in this study. Individual\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}${\\rm CF}_{{\\rm SSDE}}^{{\\rm organ}}$\\end{document} CF SSDE organ were determined for a total of 23 organs in the chest and abdominopelvic region across nine weight subcategories. For organs fully covered by the scan volume, correlation in the chest (average 1.1; range 0.7–1.4) and abdominopelvic region (average 0.9; range 0.7–1.3) was near unity. For organ/tissue that extended beyond the scan volume (i.e., skin, bone marrow, and bone surface), correlation was determined to be poor (average 0.3; range: 0.1–0.4) for both the chest and abdominopelvic regions, respectively. A means to estimate patient organ dose was demonstrated. Calculated patient organ dose, using patient SSDE and \\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}${\\rm CF}_{{\\rm SSDE}}^{{\\rm organ}}$\\end{document} CF SSDE organ , was compared to previously published pediatric patient doses that accounted for patient size in their dose calculation, and was found to agree in the chest to better than an average of 5% (27.6/26.2) and in the abdominopelvic region to better than 2% (73.4/75.0). Conclusions: For organs fully covered within the scan volume, the average correlation of SSDE and organ absolute dose was found to be better than ±10%. In addition, this study provides a complete list of organ dose correlation factors (\\documentclass[12pt]{minimal} \\usepackage{amsmath} \\usepackage{wasysym} \\usepackage{amsfonts} \\usepackage{amssymb} \\usepackage{amsbsy} \\usepackage{upgreek} \\usepackage{mathrsfs} \\setlength{\\oddsidemargin}{-69pt} \\begin{document} }{}${\\rm CF}_{{\\rm SSDE}}^{{\\rm organ}}$\\end{document} CF SSDE organ ) for the chest and abdominopelvic regions, and describes a simple methodology to estimate individual pediatric patient organ dose based on patient SSDE. PMID:24989395

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryan, E. Ronan, E-mail: ronan@ronanryan.com; Thornton, Raymond; Sofocleous, Constantinos T.

    PurposeTo quantify radiation exposure to the primary operator and staff during PET/CT-guided interventional procedures.MethodsIn this prospective study, 12 patients underwent PET/CT-guided interventions over a 6 month period. Radiation exposure was measured for the primary operator, the radiology technologist, and the nurse anesthetist by means of optically stimulated luminescence dosimeters. Radiation exposure was correlated with the procedure time and the use of in-room image guidance (CT fluoroscopy or ultrasound).ResultsThe median effective dose was 0.02 (range 0-0.13) mSv for the primary operator, 0.01 (range 0-0.05) mSv for the nurse anesthetist, and 0.02 (range 0-0.05) mSv for the radiology technologist. The median extremitymore » dose equivalent for the operator was 0.05 (range 0-0.62) mSv. Radiation exposure correlated with procedure duration and with the use of in-room image guidance. The median operator effective dose for the procedure was 0.015 mSv when conventional biopsy mode CT was used, compared to 0.06 mSv for in-room image guidance, although this did not achieve statistical significance as a result of the small sample size (p = 0.06).ConclusionThe operator dose from PET/CT-guided procedures is not significantly different than typical doses from fluoroscopically guided procedures. The major determinant of radiation exposure to the operator from PET/CT-guided interventional procedures is time spent in close proximity to the patient.« less

  5. Dosimetry study of diagnostic X-ray using doped iodide normoxic polymer gels

    NASA Astrophysics Data System (ADS)

    Huang, Y. R.; Chang, Y. J.; Hsieh, L. L.; Liu, M. H.; Liu, J. S.; Chu, C. H.; Hsieh, B. T.

    2014-11-01

    In radiotherapy, polymer gel dosimeters are used for three-dimensional (3D) dose distribution. However, the doses are within the Gy range. In this study, we attempted to develop a low-dose 3D dosimeter within the mGy range for diagnostic radiology. The effect of the iodinated compound was used as a dose enhancement sensitizer to enhance the dose sensitivity of normoxic polymer gel dosimeters. This study aims to use N-isopropylacrylamide(NIPAM)-based and methacrylic acid (MAGAT)-based gels to evaluate the potential dose enhancement sensitizer, as well as to compare two gels that may be suitable for measuring diagnostic radiation doses. The suitable formulation of NIPAM gel [5% (w/w) gelatin, 5% (w/w) NIPAM, 3% (w/w) N,N‧-methylenebisacrylamide (BIS), 5 mM tetrakis (hydroxymethyl) phosphonium chloride (THPC), and 87% (w/w) deionized distilled water] and MAGAT gel (4% MAA, 9% gelatin, 87% deionized water, and 10 mM THPC) were used and loaded with clinical iodinated contrast medium agent (Iobitridol, Xenetix® 350). Irradiation was conducted using X-ray computed tomography. The irradiation doses ranged from 0 mGy to 80 mGy. Optical computed tomography was the employed gel measurement system. The results indicate that the iodinated contrast agent yields a quantifiable dose enhancement ratio. The dose enhancement ratios of NIPAM and MAGAT gels are 3.35±0.6 and 1.36±0.3, respectively. The developed NIPAM gel in this study could be suitable for measuring diagnostic radiation doses.

  6. Aripiprazole Lauroxil: Pharmacokinetic Profile of This Long-Acting Injectable Antipsychotic in Persons With Schizophrenia.

    PubMed

    Hard, Marjie L; Mills, Richard J; Sadler, Brian M; Turncliff, Ryan Z; Citrome, Leslie

    2017-06-01

    Aripiprazole lauroxil is an extended-release prodrug of aripiprazole for intramuscular injection, approved for schizophrenia treatment. We developed a population pharmacokinetic (PopPK) model to characterize aripiprazole lauroxil PK and evaluate dosing scenarios likely to be encountered in clinical practice. Data from 616 patients with schizophrenia, collected from 5 clinical studies, were used to construct the PopPK model. The model was subsequently used to evaluate various dose levels and frequency and the impact of dosing delay on aripiprazole concentrations. The results of the model indicate that aripiprazole is released into the systemic circulation after 5 to 6 days, and release continues for an additional 36 days. The slow increase in aripiprazole concentration after injection necessitates the coadministration of oral aripiprazole for 21 days with the first injection. Based on the PopPK model simulations, a dosing interval of 882 mg every 6 weeks results in aripiprazole concentrations that fall within the concentration range associated with the efficacious aripiprazole lauroxil dose range (441-882 mg dosed monthly). A 662-mg monthly dose also resulted in aripiprazole concentrations within the efficacious dose range. Aripiprazole lauroxil administration results in prolonged exposure, such that dose delays of 2 to 4 weeks, depending on the dose regimen, do not require oral aripiprazole supplementation upon resumption of dosing. This PopPK model and model-based simulations were effective means for evaluating aripiprazole lauroxil dosing regimens and management of missed doses. Such analyses play an important role in determining the use of this long-acting antipsychotic in clinical practice.

  7. Cumulative radiation exposure and cancer risk estimation in children with heart disease.

    PubMed

    Johnson, Jason N; Hornik, Christoph P; Li, Jennifer S; Benjamin, Daniel K; Yoshizumi, Terry T; Reiman, Robert E; Frush, Donald P; Hill, Kevin D

    2014-07-08

    Children with heart disease are frequently exposed to imaging examinations that use ionizing radiation. Although radiation exposure is potentially carcinogenic, there are limited data on cumulative exposure and the associated cancer risk. We evaluated the cumulative effective dose of radiation from all radiation examinations to estimate the lifetime attributable risk of cancer in children with heart disease. Children ≤6 years of age who had previously undergone 1 of 7 primary surgical procedures for heart disease at a single institution between 2005 and 2010 were eligible for the study. Exposure to radiation-producing examinations was tabulated, and cumulative effective dose was calculated in millisieverts. These data were used to estimate lifetime attributable risk of cancer above baseline using the approach of the Committee on Biological Effects of Ionizing Radiation VII. The cohort included 337 children exposed to 13 932 radiation examinations. Conventional radiographs represented 92% of examinations, whereas cardiac catheterization and computed tomography accounted for 81% of cumulative exposure. Overall median cumulative effective dose was 2.7 mSv (range, 0.1-76.9 mSv), and the associated lifetime attributable risk of cancer was 0.07% (range, 0.001%-6.5%). Median lifetime attributable risk of cancer ranged widely depending on surgical complexity (0.006%-1.6% for the 7 surgical cohorts) and was twice as high in females per unit exposure (0.04% versus 0.02% per 1-mSv effective dose for females versus males, respectively; P<0.001). Overall radiation exposures in children with heart disease are relatively low; however, select cohorts receive significant exposure. Cancer risk estimation highlights the need to limit radiation dose, particularly for high-exposure modalities. © 2014 American Heart Association, Inc.

  8. Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air

    DOE PAGES

    Hiller, Mauritius; Dewji, Shaheen Azim

    2017-02-16

    Dose rate coefficients computed using the International Commission on Radiological Protection (ICRP) reference adult female voxel phantom were compared with values computed using the Oak Ridge National Laboratory (ORNL) adult female stylized phantom in an air submersion exposure geometry. This is a continuation of previous work comparing monoenergetic organ dose rate coefficients for the male adult phantoms. With both the male and female data computed, effective dose rate as defined by ICRP Publication 103 was compared for both phantoms. Organ dose rate coefficients for the female phantom and ratios of organ dose rates for the voxel and stylized phantoms aremore » provided in the energy range from 30 to 5 MeV. Analysis of the contribution of the organs to effective dose is also provided. Lastly, comparison of effective dose rates between the voxel and stylized phantoms was within 8% at 100 keV and is <5% between 200 and 5000 keV.« less

  9. Comparison of Monoenergetic Photon Organ Dose Rate Coefficients for the Female Stylized and Voxel Phantoms Submerged in Air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hiller, Mauritius; Dewji, Shaheen Azim

    Dose rate coefficients computed using the International Commission on Radiological Protection (ICRP) reference adult female voxel phantom were compared with values computed using the Oak Ridge National Laboratory (ORNL) adult female stylized phantom in an air submersion exposure geometry. This is a continuation of previous work comparing monoenergetic organ dose rate coefficients for the male adult phantoms. With both the male and female data computed, effective dose rate as defined by ICRP Publication 103 was compared for both phantoms. Organ dose rate coefficients for the female phantom and ratios of organ dose rates for the voxel and stylized phantoms aremore » provided in the energy range from 30 to 5 MeV. Analysis of the contribution of the organs to effective dose is also provided. Lastly, comparison of effective dose rates between the voxel and stylized phantoms was within 8% at 100 keV and is <5% between 200 and 5000 keV.« less

  10. The feasibility of universal DLP-to-risk conversion coefficients for body CT protocols

    NASA Astrophysics Data System (ADS)

    Li, Xiang; Samei, Ehsan; Segars, W. Paul; Paulson, Erik K.; Frush, Donald P.

    2011-03-01

    The effective dose associated with computed tomography (CT) examinations is often estimated from dose-length product (DLP) using scanner-independent conversion coefficients. Such conversion coefficients are available for a small number of examinations, each covering an entire region of the body (e.g., head, neck, chest, abdomen and/or pelvis). Similar conversion coefficients, however, do not exist for examinations that cover a single organ or a sub-region of the body, as in the case of a multi-phase liver examination. In this study, we extended the DLP-to-effective dose conversion coefficient (k factor) to a wide range of body CT protocols and derived the corresponding DLP-to-cancer risk conversion coefficient (q factor). An extended cardiactorso (XCAT) computational model was used, which represented a reference adult male patient. A range of body CT protocols used in clinical practice were categorized based on anatomical regions examined into 10 protocol classes. A validated Monte Carlo program was used to estimate the organ dose associated with each protocol class. Assuming the reference model to be 20 years old, effective dose and risk index (an index of the total risk for cancer incidence) were then calculated and normalized by DLP to obtain the k and q factors. The k and q factors varied across protocol classes; the coefficients of variation were 28% and 9%, respectively. The small variation exhibited by the q factor suggested the feasibility of universal q factors for a wide range of body CT protocols.

  11. [Intermediary effectiveness of procaine and procaine metabolites following oral administration].

    PubMed

    Kaemmerer, K; Kietzmann, M

    1989-01-01

    The influence of orally administrated procaine hydrochloride and of its metabolites diethylaminoethanol, monoethylaminoethanol and ethanolamine on specific intermediary processes in rats was tested. While the animals got procaine hydrochloride in a single dose or via food the incorporation rate of amino acids in protein was measured in homogenisates of liver tissue by the incorporation of a mixture of 14C-amino acids. Procaine hydrochloride, the commercial product K. H. 3, as well as diethylaminoethanol, monoethylaminoethanol and ethanolamine increased the amino acid incorporation rate in a dose and time dependent mode, while p-aminobenzoic acid remained without any effect. The dose of procaine hydrochloride inducing a maximal reaction was in the range of 50 to 100 mg/kg b. w. (250 to 500 mg/kg food). The minimal active dose was nearly at 10 mg/kg b. w. Paying regard to a metabolic factor of 10 the effective dose-range is nearly the dose used in experience with human beings to influence geriatric complaints. In the study described here haematoporphyrine (a component of the commercial product K. H. 3, not absorbed) shows no specific intermediary effect. May be it promotes the intestinal absorption of procaine hydrochloride by protection against intestinal hydrolysis. The intermediary effect of procaine hydrochloride is to measure on cellular or subcellular level without compatibility to the activity as a local anaesthetic. With regard to other intermediary effects mentioned in the literature like growth promotion or inhibition of monoamine oxidase activity, it is discussed whether the increase of the hepatic amino acid incorporation rate is corresponding to geriatric experiences made with procaine hydrochloride.

  12. Validating the Effectiveness of Switching the Vancomycin TDM Analysis Software Based on the Predictive Accuracy.

    PubMed

    Imai, Shungo; Yamada, Takehiro; Ishiguro, Nobuhisa; Miyamoto, Takenori; Kagami, Keisuke; Tomiyama, Naoki; Niinuma, Yusuke; Nagasaki, Daisuke; Suzuki, Koji; Yamagami, Akira; Kasashi, Kumiko; Kobayashi, Masaki; Iseki, Ken

    2017-01-01

    Based on the predictive performance in our previous study, we switched the therapeutic drug monitoring (TDM) analysis software for dose setting of vancomycin (VCM) from "Vancomycin MEEK TDM analysis software Ver2.0" (MEEK) to "SHIONOGI-VCM-TDM ver.2009" (VCM-TDM) in January 2015. In the present study, our aim was to validate the effectiveness of the changing VCM TDM analysis software in initial dose setting of VCM. The enrolled patients were divided into two groups, each having 162 patients in total, who received VCM with the initial dose set using MEEK (MEEK group) or VCM-TDM (VCM-TDM group). We compared the rates of attaining the therapeutic range (trough value; 10-20 μg/mL) of serum VCM concentration between the groups. Multivariate logistic regression analysis was performed to confirm that changing the VCM TDM analysis software was an independent factor related to attaining the therapeutic range. Switching the VCM TDM analysis software from MEEK to VCM-TDM improved the rate of attaining the therapeutic range by 21.6% (MEEK group: 42.6% vs. VCM-TDM group: 64.2%, p<0.01). Patient age ≥65 years, concomitant medication (furosemide) and the TDM analysis software used VCM-TDM were considered to be independent factors for attaining the therapeutic range. These results demonstrated the effectiveness of switching the VCM TDM analysis software from MEEK to VCM-TDM for initial dose setting of VCM.

  13. Pharmacodynamics and pharmacokinetics of single doses of subcutaneous pegylated human G-CSF mutant (Ro 25-8315) in healthy volunteers: comparison with single and multiple daily doses of filgrastim.

    PubMed

    van Der Auwera, P; Platzer, E; Xu, Z X; Schulz, R; Feugeas, O; Capdeville, R; Edwards, D J

    2001-04-01

    Ro 25-8315 is produced by conjugation of rhG-CSF mutant with polyethylene glycol (PEG). The purpose of this study was to examine the pharmacodynamics and pharmacokinetics of Ro 25-8315 in comparison with Filgrastim (rhG-CSF). Subjects received single subcutaneous doses of Ro 25-8315 ranging from 10 to 150 microg/kg using a double-blind, randomized, placebo-controlled design. Filgrastim was administered as a single dose (5 or 10 microg/kg) and, following a 14-day washout period, daily for 7 days. Ro 25-8315 increased absolute neutrophil count (ANC) by 6- to 8-fold and CD34+ cell count more than 30-fold at the highest doses tested. Single doses (60-150 microg/kg) of Ro 25-8315 and multiple doses of Filgrastim had similar effects on ANC and CD34+, although Ro 25-8315 had a greater effect on CFU-GM. The pharmacokinetics of Ro 25-8315 were dose-dependent, with peak concentrations and area under the serum concentration-time curve (AUC) increasing 100-fold over the range of doses studied. Time to reach peak concentration (T(max)) and half-life of Ro 25-8315 averaged 20-30 hr at all doses, approximately three times longer than with Filgrastim. Adverse events were not serious and occurred with similar frequency with both products. Pegylation of rhG-CSF mutant results in more desirable pharmacokinetic properties and a longer duration of action with effective increases in ANC and measures of peripheral blood progenitor cell mobilization for at least 1 week. Copyright 2001 Wiley-Liss, Inc.

  14. [Carcinogenic efficacy of the transuranium elements americium-241 and curium-244].

    PubMed

    Rudnitskaia, E I

    1984-01-01

    Albino female rats were used in the experiments. After a single intraperitoneal administration of 241Am and 244Cm chloride is doses ranging from 0.37 to 185 kBq/kg (14 doses were used) it was established that the doses applied had different effect on the average life of animals. The largest doses shortened and the lowest increased the life span of experimental animals as compared to the controls. The carcinogenic effect of the studied radionuclides and the development of malignant tumors were detected at sufficiently low doses absorbed. Malignant tumors developed in the experimental and control animals were different not only in their incidence but also their localization and spectrum.

  15. Effects of low doses of caffeine on cognitive performance, mood and thirst in low and higher caffeine consumers.

    PubMed

    Smit, H J; Rogers, P J

    2000-10-01

    Caffeine is present in many widely consumed drinks and some foods. In the fairly extensive literature on the psychostimulant effects of caffeine, there are few dose-response studies and even fewer studies of the effects of doses of caffeine lower than 50 mg (the range of the amounts of caffeine contained in, for example, a typical serving of tea or cola). This study measured the effects of 0, 12.5, 25, 50 and 100 mg caffeine on cognitive performance, mood and thirst in adults with low and moderate to high habitual caffeine intakes. This was a double-blind, within-subjects study. Following overnight caffeine abstinence, participants (n=23) completed a test battery once before and three times after placebo or caffeine administration. The test battery consisted of two performance tests, a long duration simple reaction time task and a rapid visual information processing task, and a mood questionnaire (including also an item on thirst). Effects on performance and mood confirmed a psychostimulant action of caffeine. All doses of caffeine significantly affected cognitive performance, and the dose-response relationships for these effects were rather flat. The effects on performance were more marked in individuals with a higher level of habitual caffeine intake, whereas caffeine increased thirst only in low caffeine consumers. After overnight caffeine abstinence, caffeine can significantly affect cognitive performance, mood and thirst at doses within and even lower than the range of amounts of caffeine contained in a single serving of popular caffeine-containing drinks. Regular caffeine consumers appear to show substantial tolerance to the thirst-increasing but not to the performance and mood effects of caffeine.

  16. Dual effects of Rho-kinase inhibitors on a rat model of inflammatory pain.

    PubMed

    Paiva-Lima, Patricia; Bakhle, Y S; Francischi, Janetti Nogueira

    2014-01-01

    Rho-kinases (ROCKs), a family of small GTP-dependent enzymes, are involved in a range of pain models, and their inhibition typically leads to antinociceptive effects. To study the effects of inhibiting ROCKs using two known inhibitors, Y27632 and HA1077 (fasudil), administered locally, on nociception and paw edema in rats. A range of doses of Y27632 or HA1077 (2.5 μg to 1000 μg) were injected locally into rat paws alone or in combination with carrageenan, a known proinflammatory stimulus. Nociceptive responses to mechanical stimuli and increased paw volume, reflecting edema formation, were measured at 2 h and 3 h, using a Randall-Selitto apparatus and a hydroplethysmometer, respectively. Animals treated with either ROCK inhibitor showed biphasic nociceptive effects, with lower doses being associated with pronociceptive, and higher doses with antinociceptive responses. In contrast, a monophasic dose-dependent increase in edema was observed in the same animals. Local injection of 8-bromo-cyclic (c)GMP, an activator of the nitric oxide⁄cGMP⁄protein kinase G pathway, also produced biphasic effects on nociceptive responses in rat paws; however, low doses were antinociceptive and high doses were pronociceptive. Local administration of cytochalasin B, an inhibitor of actin polymerization and a downstream mediator of ROCK activity, reversed the antinociceptive effect of Y27632. The results of the present study suggest that ROCKs participate in the local mechanisms associated with nociception⁄antinociception and inflammation, with a possible involvement of the nitric oxide⁄cGMP⁄protein kinase G pathway. Also, drug effects following local administration may differ markedly from the effects following systemic administration. Finally, separate treatment of pain and edema may be needed to maximize clinical benefit in inflammatory pain.

  17. Investigation of vacuum pumping on the dose response of the MAGAS normoxic polymer gel dosimeter.

    PubMed

    Venning, A J; Mather, M L; Baldock, C

    2005-06-01

    The effect of vacuum pumping on the dose response of the MAGAS polymer gel dosimeter has been investigated. A delay of several days post-manufacture before irradiation was previously necessary due to the slow oxygen scavenging of ascorbic acid. The MAGAS polymer gel dosimeter was vacuum pumped before gelation to remove dissolved oxygen. The MAGAS polymer gel dosimeter was poured into glass screw-top vials, which were irradiated at various times, post-manufacture to a range of doses. Magnetic resonance imaging techniques were used to determine the R2-dose response and R2-dose sensitivity of the MAGAS polymer gel. The results were compared with a control batch of MAGAS polymer gel that was not vacuum pumped. It was shown that vacuum pumping on the MAGAS polymer gel solution immediately prior to sealing in glass screw-top vials initially increases the R2-dose response and R2-dose sensitivity of the dosimeter. An increase in the R2-dose response and R2-dose sensitivity was observed with increasing time between manufacture and irradiation. Over the range of post-manufacture irradiation times investigated, the greatest R2-dose response and R2-dose sensitivity occurred at 96 hours.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mead, H; St. Jude Children’s Research Hospital, Memphis, TN; Brady, S

    Purpose: To discover if a previously published methodology for estimating patient-specific organ dose in a pediatric population (5–55kg) is translatable to the adult sized patient population (> 55 kg). Methods: An adult male anthropomorphic phantom was scanned with metal oxide semiconductor field effect transistor (MOSFET) dosimeters placed at 23 organ locations in the chest and abdominopelvic regions to determine absolute organ dose. Organ-dose-to-SSDE correlation factors were developed by dividing individual phantom organ doses by SSDE of the phantom; where SSDE was calculated at the center of the scan volume of the chest and abdomen/pelvis separately. Organ dose correlation factors developedmore » in phantom were multiplied by 28 chest and 22 abdominopelvic patient SSDE values to estimate organ dose. The median patient weight from the CT examinations was 68.9 kg (range 57–87 kg) and median age was 17 years (range 13–28 years). Calculated organ dose estimates were compared to published Monte Carlo simulated patient and phantom results. Results: Organ-dose-to-SSDE correlation was determined for a total of 23 organs in the chest and abdominopelvic regions. For organs fully covered by the scan volume, correlation in the chest (median 1.3; range 1.1–1.5) and abdominopelvic (median 0.9; range 0.7–1.0) was 1.0 ± 10%. For organs that extended beyond the scan volume (i.e. skin bone marrow and bone surface) correlation was determined to be a median of 0.3 (range 0.1–0.4). Calculated patient organ dose using patient SSDE agreed to better than 6% (chest) and 15% (abdominopelvic) to published values. Conclusion: This study demonstrated that our previous published methodology for calculating organ dose using patient-specific SSDE for the chest and abdominopelvic regions is translatable to adult sized patients for organs fully covered by the scan volume.« less

  19. Dose-response relationships in a microneutralization test for foot-and-mouth disease viruses.

    PubMed Central

    Booth, J. C.; Rweyemamu, M. M.; Pay, T. W.

    1978-01-01

    Two-dimensional quantal microneutralization tests on foot-and-mouth disease viruses, in which neutralizing antibody activity was titrated against a serial range of virus doses, demonstrated a variety of dose-response curves some of which were rectilinear, others clearly curvilinear. Moreover, in the case of the non-linear responses obtained with some antisera, the shape of the curve was such that antibody titres recorded with doses of virus ranging from 10(3)-10(5) TCD50 were closely similar. Studies were carried out on the effect of varying the conditions of the test on the shape of the dose-response curve: significant differences were obtained after treatment of the antiserum-virus mixtures with anti-species globulin, and when the test was assayed in cells of differing susceptibility to infection. PMID:202650

  20. Absorbed organ and effective doses from digital intra-oral and panoramic radiography applying the ICRP 103 recommendations for effective dose estimations

    PubMed Central

    Thilander-Klang, Anne; Ylhan, Betȕl; Lofthag-Hansen, Sara; Ekestubbe, Annika

    2016-01-01

    Objective: During dental radiography, the salivary and thyroid glands are at radiation risk. In 2007, the International Commission on Radiological Protection (ICRP) updated the methodology for determining the effective dose, and the salivary glands were assigned tissue-specific weighting factors for the first time. The aims of this study were to determine the absorbed dose to the organs and to calculate, applying the ICRP publication 103 tissue-weighting factors, the effective doses delivered during digital intraoral and panoramic radiography. Methods: Thermoluminescent dosemeter measurements were performed on an anthropomorphic head and neck phantom. The organ-absorbed doses were measured at 30 locations, representing different radiosensitive organs in the head and neck, and the effective dose was calculated according to the ICRP recommendations. Results: The salivary glands and the oral mucosa received the highest absorbed doses from both intraoral and panoramic radiography. The effective dose from a full-mouth intraoral examination was 15 μSv and for panoramic radiography, the effective dose was in the range of 19–75 μSv, depending on the panoramic equipment used. Conclusion: The effective dose from a full-mouth intraoral examination is lower and that from panoramic radiography is higher than previously reported. Clinicians should be aware of the higher effective dose delivered during panoramic radiography and the risk–benefit profile of this technique must be assessed for the individual patient. Advances in knowledge: The effective dose of radiation from panoramic radiography is higher than previously reported and there is large variability in the delivered radiation dosage among the different types of equipment used. PMID:27452261

  1. Effect of gamma irradiation on the color, structure and morphology of nickel-doped polyvinyl alcohol films: Alternative use as dosimeter or irradiation indicator

    NASA Astrophysics Data System (ADS)

    Raouafi, A.; Daoudi, M.; Jouini, K.; Charradi, K.; Hamzaoui, A. H.; Blaise, P.; Farah, K.; Hosni, F.

    2018-06-01

    Nickel-doped poly vinyl alcohol (PVA) films were developed for potential application in industrial sectors like radiation processing. We report in this paper the results of an experimental investigation of 60Co source γ-radiation effect on colorimetric, structural and morphological properties of PVA films doped with 0.5% Ni2+ ions (PVA/Ni2+). The PVA/Ni2+ films were irradiated by different gamma-radiation doses varying from 5 to 100 kGy. Color modification of films were studied using L∗, a∗ and b∗ color space measurements as function of the γ-dose and post-irradiation time. The visual change in all samples was verified by microstructure analysis, Fourier transforms infrared (FTIR) spectroscopy, X-Rays diffraction (XRD) and scanning electron microscopy (SEM). The color space exhibited a linear dose response at a dose ranging from 5 to 50 kGy, and then it reached saturation for higher γ-doses. The calculated color changes (ΔE) show a linear dose response relationship from 9.90 to 115.02 in the dose range from 0 to 50 kGy. It showed also the activation of stable color centers. The variability of the color change did not exceed 3% during 80 h (h) post-irradiation. Furthermore, the microstructure analysis evidenced that the color modification due to the optical activation of nickel-oxide (NiO) color center were obtained by complexing Ni2+ ions in irradiated PVA films. The obtained results inspire the possibility to use PVA films for the control process in industrial radiation facilities in dose range 5-50 kGy.

  2. Population Pharmacokinetics of Rifapentine and Desacetyl Rifapentine in Healthy Volunteers: Nonlinearities in Clearance and Bioavailability

    PubMed Central

    Lu, Yanhui; Bliven-Sizemore, Erin; Weiner, Marc; Nuermberger, Eric; Burman, William; Dorman, Susan E.; Dooley, Kelly E.

    2014-01-01

    Rifapentine is under active investigation as a potent drug that may help shorten the tuberculosis (TB) treatment duration. A previous rifapentine dose escalation study with daily dosing indicated a possible decrease in bioavailability as the dose increased and an increase in clearance over time for rifapentine and its active metabolite, desacetyl rifapentine. This study aimed to assess the effects of increasing doses on rifapentine absorption and bioavailability and to evaluate the clearance changes over 14 days. A population analysis was performed with nonlinear mixed-effects modeling. Absorption, time-varying clearance, bioavailability, and empirical and semimechanistic autoinduction models were investigated. A one-compartment model linked to a transit compartment absorption model best described the data. The bioavailability of rifapentine decreased linearly by 2.5% for each 100-mg increase in dose. The autoinduction model suggested a dose-independent linear increase in clearance of the parent drug and metabolite over time from 1.2 and 3.1 liters · h−1, respectively, after a single dose to 2.2 and 5.0 liters · h−1, respectively, after 14 once-daily doses, with no plateau being reached by day 14. In clinical trial simulations using the final model, rifapentine demonstrated less-than-dose-proportional pharmacokinetics, but there was no plateau in exposures over the dose range tested (450 to 1,800 mg), and divided dosing increased exposures significantly. Thus, the proposed compartmental model incorporating daily dosing of rifapentine over a wide range of doses and time-related changes in bioavailability and clearance provides a useful tool for estimation of drug exposure that can be used to optimize rifapentine dosing for TB treatment. (This study has been registered at ClinicalTrials.gov under registration no. NCT01162486.) PMID:24614383

  3. The dichotomy of memantine treatment for ischemic stroke: dose-dependent protective and detrimental effects

    PubMed Central

    Trotman, Melissa; Vermehren, Philipp; Gibson, Claire L; Fern, Robert

    2015-01-01

    Excitotoxicity is a major contributor to cell death during the acute phase of ischemic stroke but aggressive pharmacological targeting of excitotoxicity has failed clinically. Here we investigated whether pretreatment with low doses of memantine, within the range currently used and well tolerated for the treatment of Alzheimer's disease, produce a protective effect in stroke. A coculture preparation exposed to modeled ischemia showed cell death associated with rapid glutamate rises and cytotoxic Ca2+ influx. Cell death was significantly enhanced in the presence of high memantine concentrations. However, low memantine concentrations significantly protected neurons and glia via excitotoxic cascade interruption. Mice were systemically administered a range of memantine doses (0.02, 0.2, 2, 10, and 20 mg/kg/day) starting 24 hours before 60 minutes reversible focal cerebral ischemia and continuing for a 48-hour recovery period. Low dose (0.2 mg/kg/day) memantine treatment significantly reduced lesion volume (by 30% to 50%) and improved behavioral outcomes in stroke lesions that had been separated into either small/striatal or large/striatocortical infarcts. However, higher doses of memantine (20 mg/kg/day) significantly increased injury. These results show that clinically established low doses of memantine should be considered for patients ‘at risk' of stroke, while higher doses are contraindicated. PMID:25407270

  4. Apixaban, an oral, direct factor Xa inhibitor: single dose safety, pharmacokinetics, pharmacodynamics and food effect in healthy subjects

    PubMed Central

    Frost, Charles; Wang, Jessie; Nepal, Sunil; Schuster, Alan; Barrett, Yu Chen; Mosqueda-Garcia, Rogelio; Reeves, Richard A; LaCreta, Frank

    2013-01-01

    Aims To evaluate apixaban single dose safety, tolerability, pharmacokinetics and pharmacodynamics and assess the effect of food on apixaban pharmacokinetics. Methods A double-blind, placebo-controlled, single ascending-dose, first-in-human study assessed apixaban safety, pharmacokinetics and pharmacodynamics in healthy subjects randomized to oral apixaban (n = 43; 0.5–2.5 mg as solution or 5–50 mg as tablets) or placebo (n = 14) under fasted conditions. An open label, randomized, two treatment crossover study investigated apixaban pharmacokinetics/pharmacodynamics in healthy subjects (n = 21) administered apixaban 10 mg in fasted and fed states. Both studies measured apixaban plasma concentration, international normalized ratio (INR), activated partial thromboplastin time (aPTT) and prothrombin time (PT) or a modified PT (mPT). Results In the single ascending-dose study increases in apixaban exposure appeared dose-proportional. Median tmax occurred 1.5–3.3 h following oral administration. Mean terminal half-life ranged between 3.6 and 6.8 h following administration of solution doses ≤2.5 mg and between 11.1 and 26.8 h for tablet doses ≥5 mg. Concentration-related changes in pharmacodynamic assessments were observed. After a 50 mg dose, peak aPTT, INR and mPT increased by 1.2-, 1.6- and 2.9-fold, respectively, from baseline. In the food effect study: 90% confidence intervals of geometric mean ratios of apixaban Cmax and AUC in a fed vs. fasted state were within the predefined no effect (80–125%) range. Apixaban half-life was approximately 11.5 h. The effect of apixaban on INR, PT and aPTT was comparable following fed and fasted administration. Conclusions Single doses of apixaban were well tolerated with a predictable pharmacokinetic/pharmacodynamic profile and a half-life of approximately 12 h. Apixaban can be administered with or without food. PMID:22759198

  5. Effective doses in children: association with common complex imaging techniques used during interventional radiology procedures.

    PubMed

    Lai, Priscilla; McNeil, Sarah M; Gordon, Christopher L; Connolly, Bairbre L

    2014-12-01

    The purpose of this study was to determine the range of effective doses associated with imaging techniques used during interventional radiology procedures on children. A pediatric phantom set (1, 5, and 10 years) coupled with high-sensitivity metal oxide semiconductor field effect transistor (MOSFET) dosimeters was used to calculate effective doses. Twenty MOSFETs were inserted into each phantom at radiosensitive organ locations. The phantoms were exposed to mock head, chest, and abdominal interventional radiology procedures performed with different geometries and magnifications. Fluoroscopy, digital subtraction angiography (DSA), and spin angiography were simulated on each phantom. Road mapping was conducted only on the 5-year-old phantom. International Commission on Radiological Protection publication 103 tissue weights were applied to the organ doses recorded with the MOSFETs to determine effective dose. For easy application to clinical cases, doses were normalized per minute of fluoroscopy and per 10 frames of DSA or spin angiography. Effective doses from DSA, angiography, and fluoroscopy were higher for younger ages because of magnification use and were largest for abdominal procedures. DSA of the head, chest, and abdomen (normalized per 10 frames) imparted doses 2-3 times as high as corresponding doses per minute of fluoroscopy while all other factors remained unchanged (age, projection, collimation, magnification). Three to five frames of DSA imparted an effective dose equal to doses from 1 minute of fluoroscopy. Doses from spin angiography were almost one-half the doses received from an equivalent number of frames of DSA. Patient effective doses during interventional procedures vary substantially depending on procedure type but tend to be higher because of magnification use in younger children and higher in the abdomen.

  6. 80 MeV C{sup 6+} ion irradiation effects on the DC electrical characteristics of silicon NPN power transistors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bharathi, M. N.; Vinayakprasanna, N. H.; Prakash, A. P. Gnana, E-mail: gnanaprakash@physics.uni-mysore.ac.in

    The total dose effects of 80 MeV C{sup 6+} ions on the DC electrical characteristics of Silicon NPN rf power transistors have been studied in the dose range of 100 krad to 100 Mrad. The SRIM simulation was used to understand the energy loss and range of the ions in the transistor structure. The different electrical parameters such as Gummel characteristics, excess base current (ΔI{sub B} = I{sub Bpost} - I{sub Bpre}), dc forward current gain (h{sub FE}), transconductance (g{sub m}), displacement damage factor (K) and output characteristics (V{sub CE}-I{sub C}) were studied systematically before and after irradiation. The significantmore » degradation in base current (I{sub B}) and h{sub FE} was observed after irradiation. Isochronal annealing study was conducted on the irradiated transistors to analyze the recovery in different electrical parameters. These results were compared with {sup 60}C0 gamma irradiation results in the same dose range.« less

  7. Agonistic TAM-163 antibody targeting tyrosine kinase receptor-B: applying mechanistic modeling to enable preclinical to clinical translation and guide clinical trial design.

    PubMed

    Vugmeyster, Yulia; Rohde, Cynthia; Perreault, Mylene; Gimeno, Ruth E; Singh, Pratap

    2013-01-01

    TAM-163, an agonist monoclonal antibody targeting tyrosine receptor kinase-B (TrkB), is currently being investigated as a potential body weight modulatory agent in humans. To support the selection of the dose range for the first-in-human (FIH) trial of TAM-163, we conducted a mechanistic analysis of the pharmacokinetic (PK) and pharmacodynamic (PD) data (e.g., body weight gain) obtained in lean cynomolgus and obese rhesus monkeys following single doses ranging from 0.3 to 60 mg/kg. A target-mediated drug disposition (TMDD) model was used to describe the observed nonlinear PK and Emax approach was used to describe the observed dose-dependent PD effect. The TMDD model development was supported by the experimental determination of the binding affinity constant (9.4 nM) and internalization rate of the drug-target complex (2.08 h(-1)). These mechanistic analyses enabled linking of exposure, target (TrkB) coverage, and pharmacological activity (e.g., PD) in monkeys, and indicated that ≥ 38% target coverage (time-average) was required to achieve significant body weight gain in monkeys. Based on the scaling of the TMDD model from monkeys to humans and assuming similar relationship between the target coverage and pharmacological activity between monkey and humans, subcutaneous (SC) doses of 1 and 15 mg/kg in humans were projected to be the minimally and the fully pharmacologically active doses, respectively. Based on the minimal anticipated biological effect level (MABEL) approach for starting dose selection, the dose of 0.05 mg/kg (3 mg for a 60 kg human) SC was recommended as the starting dose for FIH trials, because at this dose level<10% target coverage was projected at Cmax (and all other time points). This study illustrates a rational mechanistic approach for the selection of FIH dose range for a therapeutic protein with a complex model of action.

  8. Escitalopram dose-response revisited: an alternative psychometric approach to evaluate clinical effects of escitalopram compared to citalopram and placebo in patients with major depression.

    PubMed

    Bech, Per; Tanghøj, Per; Cialdella, Philippe; Andersen, Henning Friis; Pedersen, Anders Gersel

    2004-09-01

    In continuation of a previous psychometric analysis of dose-response data for citalopram in depression, the corresponding study data for escitalopram is of interest, since escitalopram is the active enantiomer of citalopram and because citalopram was used as the active control. Revisiting those corresponding data, the psychometric properties of the Montgomery-Asberg Depression Scale (MADRS) and the Hamilton Depression Scale (HAMD) were investigated by focusing on the unidimensional HAMD6 and MADRS6. Effect sizes were calculated and compared for two dosages of escitalopram (10 mg and 20 mg daily) and between each of these two dosages and 40 mg citalopram daily. The results showed that the three depression scales MADRS6, MADRS10 and HAMD6 were psychometrically acceptable (coefficient of homogeneity of 0.40 or higher). In the severely depressed patients (MADRS10> or =30) a rather clear dose-response relationship for escitalopram was seen on all three scales after 6 and 8 wk of therapy. Thus, the effect size for 10 mg escitalopram ranged from 0.28 to 0.38 while the effect sizes for 20 mg escitalopram ranged from 0.57 to 0.77. This difference was statistically significant (p<0.01). The effect size for 40 mg citalopram ranged from 0.36 to 0.47, which is within the range found for 40 mg citalopram in our previous dose-response analysis of citalopram after 6 wk of therapy. The numerically largest difference between 20 mg escitalopram and 40 mg citalopram was seen after 8 wk of therapy for MADRS10 (effect size 0.71 vs. 0.37). An item analysis identified 'suicidal thoughts' to be the most discriminating item in this respect. These results for the severely depressed patients were confirmed by the patients self-reported quality of life evaluation. When all included patients were analysed, however, no clear dose-response relationship was seen. In conclusion, a dose-response relationship for escitalopram was seen in the severely depressed patients on all outcome scales after 6 and 8 wk of treatment. After 8 wk of treatment 20 mg escitalopram was superior to 40 mg citalopram, but not after 2 wk of treatment.

  9. Improvement of attention with amphetamine in low- and high-performing rats.

    PubMed

    Turner, Karly M; Burne, Thomas H J

    2016-09-01

    Attentional deficits occur in a range of neuropsychiatric disorders, such as schizophrenia and attention deficit hyperactivity disorder. Psychostimulants are one of the main treatments for attentional deficits, yet there are limited reports of procognitive effects of amphetamine in preclinical studies. Therefore, task development may be needed to improve predictive validity when measuring attention in rodents. This study aimed to use a modified signal detection task (SDT) to determine if and at what doses amphetamine could improve attention in rats. Sprague-Dawley rats were trained on the SDT prior to amphetamine challenge (0.1, 0.25, 0.75 and 1.25 mg/kg). This dose range was predicted to enhance and disrupt cognition with the effect differing between individuals depending on baseline performance. Acute low dose amphetamine (0.1 and 0.25 mg/kg) improved accuracy, while the highest dose (1.25 mg/kg) significantly disrupted performance. The effects differed for low- and high-performing groups across these doses. The effect of amphetamine on accuracy was found to significantly correlate with baseline performance in rats. This study demonstrates that improvement in attentional performance with systemic amphetamine is dependent on baseline accuracy in rats. Indicative of the inverted U-shaped relationship between dopamine and cognition, there was a baseline-dependent shift in performance with increasing doses of amphetamine. The SDT may be a useful tool for investigating individual differences in attention and response to psychostimulants in rodents.

  10. Microfluidic Thrombosis under Multiple Shear Rates and Antiplatelet Therapy Doses

    PubMed Central

    Ku, David N.; Forest, Craig R.

    2014-01-01

    The mainstay of treatment for thrombosis, the formation of occlusive platelet aggregates that often lead to heart attack and stroke, is antiplatelet therapy. Antiplatelet therapy dosing and resistance are poorly understood, leading to potential incorrect and ineffective dosing. Shear rate is also suspected to play a major role in thrombosis, but instrumentation to measure its influence has been limited by flow conditions, agonist use, and non-systematic and/or non-quantitative studies. In this work we measured occlusion times and thrombus detachment for a range of initial shear rates (500, 1500, 4000, and 10000 s−1) and therapy concentrations (0–2.4 µM for eptifibatide, 0–2 mM for acetyl-salicylic acid (ASA), 3.5–40 Units/L for heparin) using a microfluidic device. We also measured complete blood counts (CBC) and platelet activity using whole blood impedance aggregometry. Effects of shear rate and dose were analyzed using general linear models, logistic regressions, and Cox proportional hazards models. Shear rates have significant effects on thrombosis/dose-response curves for all tested therapies. ASA has little effect on high shear occlusion times, even at very high doses (up to 20 times the recommended dose). Under ASA therapy, thrombi formed at high shear rates were 4 times more prone to detachment compared to those formed under control conditions. Eptifibatide reduced occlusion when controlling for shear rate and its efficacy increased with dose concentration. In contrast, the hazard of occlusion from ASA was several orders of magnitude higher than that of eptifibatide. Our results show similar dose efficacy to our low shear measurements using whole blood aggregometry. This quantitative and statistically validated study of the effects of a wide range of shear rate and antiplatelet therapy doses on occlusive thrombosis contributes to more accurate understanding of thrombosis and to models for optimizing patient treatment. PMID:24404131

  11. Estimation of the indoor radon and the annual effective dose from granite samples

    NASA Astrophysics Data System (ADS)

    Sola, P.; Srinuttrakul, W.; Kewsuwan, P.

    2015-05-01

    Inhalation of radon and thoron daughters increases the risk of lung cancer. The main sources of indoor radon are building materials. The aim of this research is to estimate the indoor radon and the annual effective dose from the building materials. Eighteen granite samples bought from the markets in Thailand were measured using an ionization chamber (ATMOS 12 DPX) for the radon concentration in air. Radon exhalation rates were calculated from the radon concentration in chamber. The indoor radon from the granite samples ranged from 10.04 to 55.32 Bq·m-2·h-1 with an average value of 20.30 Bq·m-2·h-1 and the annual effective dose ranged from 0.25 to 1.39 mSv·y-1 with an average value of 0.48 mSv·y-1. The results showed that the annual effective doses of three granite samples were higher than the annual exposure limit for the general public (1 mSv·y-1) recommended by the International Commission on Radiological Protection (ICRP). In addition, the relationship between the colours and radon exhalation rates of granite samples was also explained.

  12. [Cytogenetic effects of low dose radiation with different LET in human peripheral blood lymphocytes and possible mechanisms of their realization].

    PubMed

    Nasonova, E A; Shmakova, N L; Komova, O V; Mel'nikova, L A; Fadeeva, T A; Krasavin, E A

    2006-01-01

    The induction of chromosome damage by the exposure to low doses of gamma-(60)Co and accelerated carbon ions 12C in peripheral blood lymphocytes of different donors was investigated. The complex nonlinear dose-effect dependence at the range from 1 to 50-70 cGy was observed. At the doses of 1-5 cGy the cells show the highest radiosensitivity (hypersensitivity), mainly due to the chromatid-type aberration, which is typical to those spontaneously generated in the cell and believed not to be induced by the irradiation of unstimulated lymphocytes according to the classical theory of aberration formation. With the increasing dose the frequency of the aberrations decreases significantly, in some cases up to the control level. At the doses over 50-70 cGy the dose-effect curve becomes linear. The possible role of the oxidative stress, caused by radiation-induced increase in mitochondrial reactive oxigen species (ROS) release in the phenomenon of hypersensitivity (HS) at low doses is discussed as well as cytoprotective mechanisms causing the increased radioresistance at higher doses.

  13. Effect of 2',3'-didehydro-3'-deoxythymidine in an in vitro hollow-fiber pharmacodynamic model system correlates with results of dose-ranging clinical studies.

    PubMed Central

    Bilello, J A; Bauer, G; Dudley, M N; Cole, G A; Drusano, G L

    1994-01-01

    We sought to validate an in vitro system which could predict the minimal effect dose of antiretroviral agents. Mixtures of uninfected CEM cells and CEM cells chronically infected with human immunodeficiency virus (HIV) type 1 MN were exposed to 2',3'-didehydro-3'-deoxythymidine (D4T) in vitro in a hollow-fiber model which simulates the plasma concentration-time profile of D4T in patients. Drug concentration was adjusted to simulate continuous intravenous infusion, or an intravenous bolus administered twice daily. The effect of the dosing regimen was measured with viral infectivity, p24 antigen, and reverse transcriptase or PCR for unintegrated HIV DNA. Dose deescalation studies on a twice-daily dosing schedule predicted a minimum effect dose of 0.5 mg/kg of body weight per day which correlated with the results of a clinical trial. Antiviral effect was demonstrated to be independent of schedule for every 12-h dosing versus continuous infusion. Finally, at or near the minimal effect dose, efficacy appeared to depend on the viral load. The ability of this in vitro pharmacodynamic model to assess the response of HIV-infected cells to different doses and schedules of antiviral agents may be useful in the design of optimal dosing regimens for clinical trials but requires validation with other types of antiretroviral agents. PMID:8092842

  14. Hematopoietic stimulation by porphyrin photosensitizers (Invited Paper)

    NASA Astrophysics Data System (ADS)

    Levy, Julia G.; Hunt, David W. C.; Mitchell, David W.; Jamieson, Catriona H. M.

    1992-06-01

    The effects of the photosensitizers, PhotofrinTM and benozoporphyrin derivative monoacid ring A (BPD) on a variety of hematopoietic cell functions have been studied, both in the presence and absence of light activation. A marked increase in hematopoiesis was observed in the bone marrow and spleens of DBA/2 mice administered high dose Photofrin but not BPD. This was manifested in an increased relative spleen weight, nucleated spleen cell number and circulating white blood cell concentration 7 days following Photofrin injection. We have shown that BPD and light doses just below phototoxic ranges stimulate the growth of human colony forming committed myeloid progenitors as well as pluripotent stem cells grown in long term marrow culture. Studies on the effect of BPD on the function of T lymphocytes in the absence of light has also demonstrated a stimulatory effect. The dose range in which this is observed is considerably broader than that observed with light activation. The mechanisms involved in this stimulatory effect have been studied and are discussed.

  15. SEMICONDUCTOR TECHNOLOGY: An efficient dose-compensation method for proximity effect correction

    NASA Astrophysics Data System (ADS)

    Ying, Wang; Weihua, Han; Xiang, Yang; Renping, Zhang; Yang, Zhang; Fuhua, Yang

    2010-08-01

    A novel simple dose-compensation method is developed for proximity effect correction in electron-beam lithography. The sizes of exposed patterns depend on dose factors while other exposure parameters (including accelerate voltage, resist thickness, exposing step size, substrate material, and so on) remain constant. This method is based on two reasonable assumptions in the evaluation of the compensated dose factor: one is that the relation between dose factors and circle-diameters is linear in the range under consideration; the other is that the compensated dose factor is only affected by the nearest neighbors for simplicity. Four-layer-hexagon photonic crystal structures were fabricated as test patterns to demonstrate this method. Compared to the uncorrected structures, the homogeneity of the corrected hole-size in photonic crystal structures was clearly improved.

  16. Bovine spongiform encephalopathy: the effect of oral exposure dose on attack rate and incubation period in cattle - an update.

    PubMed

    Konold, Timm; Arnold, Mark E; Austin, Anthony R; Cawthraw, Saira; Hawkins, Steve A C; Stack, Michael J; Simmons, Marion M; Sayers, A Robin; Dawson, Michael; Wilesmith, John W; Wells, Gerald A H

    2012-12-05

    To provide information on dose-response and aid in modelling the exposure dynamics of the BSE epidemic in the United Kingdom groups of cattle were exposed orally to a range of different doses of brainstem homogenate of known infectious titre from clinical cases of classical bovine spongiform encephalopathy (BSE). Interim data from this study was published in 2007. This communication documents additional BSE cases, which occurred subsequently, examines possible influence of the bovine prion protein gene on disease incidence and revises estimates of effective oral exposure. Following interim published results, two further cattle, one dosed with 100 mg and culled at 127 months post exposure and the other dosed with 10 mg and culled at 110 months post exposure, developed BSE. Both had a similar pathological phenotype to previous cases. Based on attack rate and incubation period distribution according to dose, the dose estimate at which 50% of confirmed cases would be clinically affected was revised to 0.15 g of the brain homogenate used in the experiment, with a 95% confidence interval of 0.03-0.79 g. Neither the full open reading frame nor the promoter region of the prion protein gene of dosed cattle appeared to influence susceptibility to BSE, but this may be due to the sample size. Oral exposure of cattle to a large range of doses of a BSE brainstem homogenate produced disease in all dose groups. The pathological presentation resembled natural disease. The attack rate and incubation period were dependent on the dose.

  17. Estimation of radiation cancer risk in CT-KUB

    NASA Astrophysics Data System (ADS)

    Karim, M. K. A.; Hashim, S.; Bakar, K. A.; Bradley, D. A.; Ang, W. C.; Bahrudin, N. A.; Mhareb, M. H. A.

    2017-08-01

    The increased demand for computed tomography (CT) in radiological scanning examinations raises the question of a potential health impact from the associated radiation exposures. Focusing on CT kidney-ureter-bladder (CT-KUB) procedures, this work was aimed at determining organ equivalent dose using a commercial CT dose calculator and providing an estimate of cancer risks. The study, which included 64 patients (32 males and 32 females, mean age 55.5 years and age range 30-80 years), involved use of a calibrated CT scanner (Siemens-Somatom Emotion 16-slice). The CT exposures parameter including tube potential, pitch factor, tube current, volume CT dose index (CTDIvol) and dose-length product (DLP) were recorded and analyzed using CT-EXPO (Version 2.3.1, Germany). Patient organ doses, including for stomach, liver, colon, bladder, red bone marrow, prostate and ovaries were calculated and converted into cancer risks using age- and sex-specific data published in the Biological Effects of Ionizing Radiation (BEIR) VII report. With a median value scan range of 36.1 cm, the CTDIvol, DLP, and effective dose were found to be 10.7 mGy, 390.3 mGy cm and 6.2 mSv, respectively. The mean cancer risks for males and females were estimated to be respectively 25 and 46 out of 100,000 procedures with effective doses between 4.2 mSv and 10.1 mSv. Given the increased cancer risks from current CT-KUB procedures compared to conventional examinations, we propose that the low dose protocols for unenhanced CT procedures be taken into consideration before establishing imaging protocols for CT-KUB.

  18. Safety, tolerability and pharmacokinetics of the histamine H3 receptor antagonist, ABT-288, in healthy young adults and elderly volunteers

    PubMed Central

    Othman, Ahmed A; Haig, George; Florian, Hana; Locke, Charles; Zhang, Jun; Dutta, Sandeep

    2013-01-01

    Aim The objective of this work was to characterize the safety, tolerability and pharmacokinetics of ABT-288, a highly selective histamine H3 receptor antagonist, in healthy young adults and elderly subjects following single and multiple dosing in a phase 1 setting. Methods Single doses (0.1, 0.3, 1, 3, 10, 20 and 40 mg ABT-288) and multiple doses (0.5, 1.5, 3 and 6 mg ABT-288 once-daily for 14 days) were evaluated in young adults and multiple doses (0.5, 1.5, 3 and 5 mg ABT-288 once-daily for 12 days) were evaluated in elderly subjects using randomized, double-blind, placebo-controlled, dose-escalating study designs. The effect of food on ABT-288 pharmacokinetics (5 mg single dose) was evaluated using an open label, randomized, crossover design. Results ABT-288 safety, tolerability and pharmacokinetics were comparable in young and elderly subjects. Single doses up to 40 mg and multiple doses up to 3 mg once-daily were generally safe and well tolerated. The most frequently reported adverse events were hot flush, headache, abnormal dreams, insomnia, nausea and dizziness. ABT-288 exposure (AUC) was dose-proportional over the evaluated dose ranges. The mean elimination half-life ranged from 40 to 61 h across dose groups. Steady state was achieved by day 10 of once-daily dosing with 3.4- to 4.2-fold accumulation. Food did not have a clinically meaningful effect on ABT-288 exposure. Conclusions Based on the above results, 1 and 3 mg once-daily doses of ABT-288 were advanced to phase 2 evaluation in Alzheimer's patients. PMID:23016924

  19. Safety, tolerability and pharmacokinetics of the histamine H3 receptor antagonist, ABT-288, in healthy young adults and elderly volunteers.

    PubMed

    Othman, Ahmed A; Haig, George; Florian, Hana; Locke, Charles; Zhang, Jun; Dutta, Sandeep

    2013-05-01

    The objective of this work was to characterize the safety, tolerability and pharmacokinetics of ABT-288, a highly selective histamine H3 receptor antagonist, in healthy young adults and elderly subjects following single and multiple dosing in a phase 1 setting. Single doses (0.1, 0.3, 1, 3, 10, 20 and 40 mg ABT-288) and multiple doses (0.5, 1.5, 3 and 6 mg ABT-288 once-daily for 14 days) were evaluated in young adults and multiple doses (0.5, 1.5, 3 and 5 mg ABT-288 once-daily for 12 days) were evaluated in elderly subjects using randomized, double-blind, placebo-controlled, dose-escalating study designs. The effect of food on ABT-288 pharmacokinetics (5 mg single dose) was evaluated using an open label, randomized, crossover design. ABT-288 safety, tolerability and pharmacokinetics were comparable in young and elderly subjects. Single doses up to 40 mg and multiple doses up to 3 mg once-daily were generally safe and well tolerated. The most frequently reported adverse events were hot flush, headache, abnormal dreams, insomnia, nausea and dizziness. ABT-288 exposure (AUC) was dose-proportional over the evaluated dose ranges. The mean elimination half-life ranged from 40 to 61 h across dose groups. Steady state was achieved by day 10 of once-daily dosing with 3.4- to 4.2-fold accumulation. Food did not have a clinically meaningful effect on ABT-288 exposure. Based on the above results, 1 and 3 mg once-daily doses of ABT-288 were advanced to phase 2 evaluation in Alzheimer's patients. © 2012 Abbott Laboratories. British Journal of Clinical Pharmacology © 2012 The British Pharmacological Society.

  20. An estimation of Canadian population exposure to cosmic rays.

    PubMed

    Chen, Jing; Timmins, Rachel; Verdecchia, Kyle; Sato, Tatsuhiko

    2009-08-01

    The worldwide average exposure to cosmic rays contributes to about 16% of the annual effective dose from natural radiation sources. At ground level, doses from cosmic ray exposure depend strongly on altitude, and weakly on geographical location and solar activity. With the analytical model PARMA developed by the Japan Atomic Energy Agency, annual effective doses due to cosmic ray exposure at ground level were calculated for more than 1,500 communities across Canada which cover more than 85% of the Canadian population. The annual effective doses from cosmic ray exposure in the year 2000 during solar maximum ranged from 0.27 to 0.72 mSv with the population-weighted national average of 0.30 mSv. For the year 2006 during solar minimum, the doses varied between 0.30 and 0.84 mSv, and the population-weighted national average was 0.33 mSv. Averaged over solar activity, the Canadian population-weighted average annual effective dose due to cosmic ray exposure at ground level is estimated to be 0.31 mSv.

  1. Characterization of infectious dose and lethal dose of two strains of infectious hematopoietic necrosis virus (IHNV)

    USGS Publications Warehouse

    McKenney, Douglas; Kurath, Gael; Wargo, Andrew

    2016-01-01

    The ability to infect a host is a key trait of a virus, and differences in infectivity could put one virus at an evolutionary advantage over another. In this study we have quantified the infectivity of two strains of infectious hematopoietic necrosis virus (IHNV) that are known to differ in fitness and virulence. By exposing juvenile rainbow trout (Oncorhynchus mykiss) hosts to a wide range of virus doses, we were able to calculate the infectious dose in terms of ID50 values for the two genotypes. Lethal dose experiments were also conducted to confirm the virulence difference between the two virus genotypes, using a range of virus doses and holding fish either in isolation or in batch so as to calculate LD50values. We found that infectivity is positively correlated with virulence, with the more virulent genotype having higher infectivity. Additionally, infectivity increases more steeply over a short range of doses compared to virulence, which has a shallower increase. We also examined the data using models of virion interaction and found no evidence to suggest that virions have either an antagonistic or a synergistic effect on each other, supporting the independent action hypothesis in the process of IHNV infection of rainbow trout.

  2. Combined influence of CT random noise and HU-RSP calibration curve nonlinearities on proton range systematic errors

    NASA Astrophysics Data System (ADS)

    Brousmiche, S.; Souris, K.; Orban de Xivry, J.; Lee, J. A.; Macq, B.; Seco, J.

    2017-11-01

    Proton range random and systematic uncertainties are the major factors undermining the advantages of proton therapy, namely, a sharp dose falloff and a better dose conformality for lower doses in normal tissues. The influence of CT artifacts such as beam hardening or scatter can easily be understood and estimated due to their large-scale effects on the CT image, like cupping and streaks. In comparison, the effects of weakly-correlated stochastic noise are more insidious and less attention is drawn on them partly due to the common belief that they only contribute to proton range uncertainties and not to systematic errors thanks to some averaging effects. A new source of systematic errors on the range and relative stopping powers (RSP) has been highlighted and proved not to be negligible compared to the 3.5% uncertainty reference value used for safety margin design. Hence, we demonstrate that the angular points in the HU-to-RSP calibration curve are an intrinsic source of proton range systematic error for typical levels of zero-mean stochastic CT noise. Systematic errors on RSP of up to 1% have been computed for these levels. We also show that the range uncertainty does not generally vary linearly with the noise standard deviation. We define a noise-dependent effective calibration curve that better describes, for a given material, the RSP value that is actually used. The statistics of the RSP and the range continuous slowing down approximation (CSDA) have been analytically derived for the general case of a calibration curve obtained by the stoichiometric calibration procedure. These models have been validated against actual CSDA simulations for homogeneous and heterogeneous synthetical objects as well as on actual patient CTs for prostate and head-and-neck treatment planning situations.

  3. The impact of inter-fraction dose variations on biological equivalent dose (BED): the concept of equivalent constant dose.

    PubMed

    Zavgorodni, S

    2004-12-07

    Inter-fraction dose fluctuations, which appear as a result of setup errors, organ motion and treatment machine output variations, may influence the radiobiological effect of the treatment even when the total delivered physical dose remains constant. The effect of these inter-fraction dose fluctuations on the biological effective dose (BED) has been investigated. Analytical expressions for the BED accounting for the dose fluctuations have been derived. The concept of biological effective constant dose (BECD) has been introduced. The equivalent constant dose (ECD), representing the constant physical dose that provides the same cell survival fraction as the fluctuating dose, has also been introduced. The dose fluctuations with Gaussian as well as exponential probability density functions were investigated. The values of BECD and ECD calculated analytically were compared with those derived from Monte Carlo modelling. The agreement between Monte Carlo modelled and analytical values was excellent (within 1%) for a range of dose standard deviations (0-100% of the dose) and the number of fractions (2 to 37) used in the comparison. The ECDs have also been calculated for conventional radiotherapy fields. The analytical expression for the BECD shows that BECD increases linearly with the variance of the dose. The effect is relatively small, and in the flat regions of the field it results in less than 1% increase of ECD. In the penumbra region of the 6 MV single radiotherapy beam the ECD exceeded the physical dose by up to 35%, when the standard deviation of combined patient setup/organ motion uncertainty was 5 mm. Equivalently, the ECD field was approximately 2 mm wider than the physical dose field. The difference between ECD and the physical dose is greater for normal tissues than for tumours.

  4. A conversion method of air kerma from the primary, scatter, and leakage radiations to effective dose for calculating x-ray shielding barriers in mammography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kharrati, Hedi

    2005-05-01

    In this study, a new approach has been introduced for derivation of the effective dose from air kerma to calculate shielding requirements in mammography facilities. This new approach has been used to compute the conversion coefficients relating air kerma to the effective dose for the mammography reference beam series of the Netherlands Metrology Institute Van Swinden Laboratorium, National Institute of Standards and Technology, and International Atomic Energy Agency laboratories. The results show that, in all cases, the effective dose in mammography energy range is less than 25% of the incident air kerma for the primary and the scatter radiations andmore » does not exceed 75% for the leakage radiation.« less

  5. A Monte Carlo study on quantifying the amount of dose reduction by shielding the superficial organs of an Iranian 11-year-old boy

    PubMed Central

    Akhlaghi, Parisa; Hoseinian-Azghadi, Elie; Miri-Hakimabad, Hashem; Rafat-Motavalli, Laleh

    2016-01-01

    A method for minimizing organ dose during computed tomography examinations is the use of shielding to protect superficial organs. There are some scientific reports that usage of shielding technique reduces the surface dose to patients with no appreciable loss in diagnostic quality. Therefore, in this Monte Carlo study based on the phantom of a 11-year-old Iranian boy, the effect of using an optimized shield on dose reduction to body organs was quantified. Based on the impact of shield on image quality, lead shields with thicknesses of 0.2 and 0.4 mm were considered for organs exposed directly and indirectly in the scan range, respectively. The results showed that there is 50%–62% reduction in amounts of dose for organs located fully or partly in the scan range at different tube voltages and modeling the true location of all organs in human anatomy, especially the ones located at the border of the scan, range affects the results up to 49%. PMID:28144117

  6. An exponential model equation for thiamin loss in irradiated ground pork as a function of dose and temperature of irradiation

    NASA Astrophysics Data System (ADS)

    Fox, J. B.; Thayer, D. W.; Phillips, J. G.

    The effect of low dose γ-irradiation on the thiamin content of ground pork was studied in the range of 0-14 kGy at 2°C and at radiation doses from 0.5 to 7 kGy at temperatures -20, 10, 0, 10 and 20°C. The detailed study at 2°C showed that loss of thiamin was exponential down to 0kGy. An exponential expression was derived for the effect of radiation dose and temperature of irradiation on thiamin loss, and compared with a previously derived general linear expression. Both models were accurate depictions of the data, but the exponential expression showed a significant decrease in the rate of loss between 0 and -10°C. This is the range over which water in meat freezes, the decrease being due to the immobolization of reactive radiolytic products of water in ice crystals.

  7. Thermal dose dependent optical property changes of ex vivo chicken breast tissues between 500 and 1100 nm.

    PubMed

    Adams, Matthew T; Wang, Qi; Cleveland, Robin O; Roy, Ronald A

    2014-07-07

    This study examines the effectiveness of the thermal dose model in accurately predicting thermally induced optical property changes of ex vivo chicken breast between 500-1100 nm. The absorption coefficient, μa, and the reduced scattering coefficient, μ's, of samples are measured as a function of thermal dose over the range 50 °C-70 °C. Additionally, the maximum observable changes in μa and μ's are measured as a function of temperature in the range 50 °C-90 °C. Results show that the standard thermal dose model used in the majority of high-intensity focused ultrasound (HIFU) treatments is insufficient for modeling optical property changes, but that the isodose constant may be modified in order to better predict thermally induced changes. Additionally, results are presented that show a temperature dependence on changes in the two coefficients, with an apparent threshold effect occurring between 65 °C-70 °C.

  8. [Antihypoxic effect of 3-hydroxypyridine and succinic acid derivatives and their nootropic action in alloxan diabetes].

    PubMed

    Volchegorskiĭ, I A; Rassokhina, L M; Miroshnichenko, I Iu

    2011-01-01

    Relationship between the antihypoxic effect of 3-hydroxypyridine and succinic acid derivatives (emoxipine, reamberin and mexidol) and their effect on conditional learning, glycemia, and lipidemia was studied in rats with alloxan-induced diabetes. In parallel, the analogous relationship was investigated for alpha-lipoic acid that is regarded as a "gold standard" in treatment of diabetic neuropathy. It was established that single administration of emoxipine and mexidol in mice in doses equivalent to therapeutic-range doses in humans produces antihypoxic effect manifested by increased resistance to acute hypoxic hypoxia in test animals. Alpha-lipoic acid is inferior to emoxipin and mexidol in the degree of antihypoxic action. Reamberin does not exhibit this effect. The introduction of emoxipin, reamberin, mexidol, and alpha-lipoic acid in rats with alloxan diabetes during 7 or 14 days in doses equivalent to therapeutic-range doses in humans corrects conditional learning disorders in direct relationship with the antihypoxic activity of these drugs. The development of the nootropic effect of emoxipin, mexidol, and alpha-lipoic acid is related to a decrease in hyperglycemia and hyperlipidemia in rats with alloxan diabetes. The nootropic action of reamberin is accompanied by a transient hypoglycemizing effect and aggravation of dyslipidemic disorders. The antihypoxic activity of investigated drugs determines the direction and expression of their lipidemic effect, but is not correlated with the hypoglycemizing action these drugs on test animals with alloxan diabetes.

  9. Energy spectrum control for modulated proton beams.

    PubMed

    Hsi, Wen C; Moyers, Michael F; Nichiporov, Dmitri; Anferov, Vladimir; Wolanski, Mark; Allgower, Chris E; Farr, Jonathan B; Mascia, Anthony E; Schreuder, Andries N

    2009-06-01

    In proton therapy delivered with range modulated beams, the energy spectrum of protons entering the delivery nozzle can affect the dose uniformity within the target region and the dose gradient around its periphery. For a cyclotron with a fixed extraction energy, a rangeshifter is used to change the energy but this produces increasing energy spreads for decreasing energies. This study investigated the magnitude of the effects of different energy spreads on dose uniformity and distal edge dose gradient and determined the limits for controlling the incident spectrum. A multilayer Faraday cup (MLFC) was calibrated against depth dose curves measured in water for nonmodulated beams with various incident spectra. Depth dose curves were measured in a water phantom and in a multilayer ionization chamber detector for modulated beams using different incident energy spreads. Some nozzle entrance energy spectra can produce unacceptable dose nonuniformities of up to +/-21% over the modulated region. For modulated beams and small beam ranges, the width of the distal penumbra can vary by a factor of 2.5. When the energy spread was controlled within the defined limits, the dose nonuniformity was less than +/-3%. To facilitate understanding of the results, the data were compared to the measured and Monte Carlo calculated data from a variable extraction energy synchrotron which has a narrow spectrum for all energies. Dose uniformity is only maintained within prescription limits when the energy spread is controlled. At low energies, a large spread can be beneficial for extending the energy range at which a single range modulator device can be used. An MLFC can be used as part of a feedback to provide specified energy spreads for different energies.

  10. Efficacy and tolerability of high-dose phenobarbital in children with focal seizures.

    PubMed

    Okumura, Akihisa; Nakahara, Eri; Ikeno, Mitsuru; Abe, Shinpei; Igarashi, Ayuko; Nakazawa, Mika; Takasu, Michihiko; Shimizu, Toshiaki

    2016-04-01

    We retrospectively reviewed the outcomes of children with focal epilepsy treated with oral high-dose phenobarbital. We reviewed data on children (aged<15 years) with focal seizures treated with high-dose phenobarbital (>5 mg/kg/day to maintain a target serum level >40 μg/mL) for at least 6 months. Seizure frequency was evaluated after phenobarbital titration, and 1 and 2 years after high-dose phenobarbital treatment commenced. Treatment was judged effective when seizure frequencies fell by ⩾75%. Seven boys and eight girls were treated. The median age at commencement of high-dose phenobarbital therapy was 30 months. The maximal serum phenobarbital level ranged from 36.5 to 62.9 μg/mL. High-dose PB was effective in seven. In two patients, treatment was transiently effective, but seizure frequency later returned to the baseline. High-dose PB was ineffective in six. No significant association between effectiveness and any clinical variable was evident. Drowsiness was recorded in nine patients, but no patient developed a behavioral problem or hypersensitivity. Oral high-dose phenobarbital was effective in 7 of 15 patients with focal epilepsy and well tolerated. High-dose PB may be useful when surgical treatment is difficult. Copyright © 2015 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  11. A group sequential adaptive treatment assignment design for proof of concept and dose selection in headache trials.

    PubMed

    Hall, David B; Meier, Ulrich; Diener, Hans-Cristoph

    2005-06-01

    The trial objective was to test whether a new mechanism of action would effectively treat migraine headaches and to select a dose range for further investigation. The motivation for a group sequential, adaptive, placebo-controlled trial design was (1) limited information about where across the range of seven doses to focus attention, (2) a need to limit sample size for a complicated inpatient treatment and (3) a desire to reduce exposure of patients to ineffective treatment. A design based on group sequential and up and down designs was developed and operational characteristics were explored by trial simulation. The primary outcome was headache response at 2 h after treatment. Groups of four treated and two placebo patients were assigned to one dose. Adaptive dose selection was based on response rates of 60% seen with other migraine treatments. If more than 60% of treated patients responded, then the next dose was the next lower dose; otherwise, the dose was increased. A stopping rule of at least five groups at the target dose and at least four groups at that dose with more than 60% response was developed to ensure that a selected dose would be statistically significantly (p=0.05) superior to placebo. Simulations indicated good characteristics in terms of control of type 1 error, sufficient power, modest expected sample size and modest bias in estimation. The trial design is attractive for phase 2 clinical trials when response is acute and simple, ideally binary, placebo comparator is required, and patient accrual is relatively slow allowing for the collection and processing of results as a basis for the adaptive assignment of patients to dose groups. The acute migraine trial based on this design was successful in both proof of concept and dose range selection.

  12. On effective dose for radiotherapy based on doses to nontarget organs and tissues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uselmann, Adam J., E-mail: ajuselmann@wisc.edu; Thomadsen, Bruce R.

    2015-02-15

    Purpose: The National Council for Radiation Protection and Measurement (NCRP) published estimates for the collective population dose and the mean effective dose to the population of the United States from medical imaging procedures for 1980/1982 and for 2006. The earlier report ignored the effective dose from radiotherapy and the latter gave a cursory discussion of the topic but again did not include it in the population exposure for various reasons. This paper explains the methodology used to calculate the effective dose in due to radiotherapy procedures in the latter NCRP report and revises the values based on more detailed modeling.more » Methods: This study calculated the dose to nontarget organs from radiotherapy for reference populations using CT images and published peripheral dose data. Results: Using International Commission on Radiological Protection (ICRP) 60 weighting factors, the total effective dose to nontarget organs in radiotherapy patients is estimated as 298 ± 194 mSv per patient, while the U.S. population effective dose is 0.939 ± 0.610 mSv per person, with a collective dose of 283 000 ± 184 000 person Sv per year. Using ICRP 103 weighting factors, the effective dose is 281 ± 183 mSv per patient, 0.887 ± 0.577 mSv per person in the U.S., and 268 000 ± 174 000 person Sv per year. The uncertainty in the calculations is largely governed by variations in patient size, which was accounted for by considering a range of patient sizes and taking the average treatment site to nontarget organ distance. Conclusions: The methods used to estimate the effective doses from radiotherapy used in NCRP Report No. 160 have been explained and the values updated.« less

  13. Bismuth-Silicon and Bismuth-Polyurethane Composite Shields for Breast Protection in Chest Computed Tomography Examinations

    PubMed Central

    Mehnati, Parinaz; Arash, Mehran; Akhlaghi, Parisa

    2018-01-01

    The article aims at constructing protective composite shields for breasts in chest computed tomography and investigating the effects of applying these new bismuth composites on dose and image quality. Polyurethane and silicon with 5% of bismuth were fabricated as a protective shield. At first, their efficiency in attenuating the X-ray beam was investigated by calculating the total attenuation coefficients at diagnostic energy range. Then, a physical chest phantom was scanned without and with these shields at tube voltage of 120 kVp, and image parameters together with dose values were studied. The results showed that these two shields have great effects on attenuating the X-ray beam, especially for lower energies (<40 kV), and in average, the attenuation coefficients of bismuth-polyurethane composite are higher in this energy range. The maximum relative differences between the average Hounsfield units (HUs) and noises of images without and with shield for both composites in 13 regions of interest were 4.5% and 15.7%, respectively. Moreover, primary investigation confirmed the ability of both shields (especially polyurethane-bismuth composite) in dose reduction. Comparing these two composites regarding the amount of dose reduction, the changes in HU and noise, and attenuation coefficients in diagnostic energy range, it seems that polyurethane composite is more useful for dose reduction, especially for higher tube voltages. PMID:29628636

  14. Effect of Gamma Radiations on the Quality and Shelf Life of Strawberry Fruit of the Uttrakhand Region

    NASA Astrophysics Data System (ADS)

    Sharma, Prianka; Rastogi, Meetu

    2016-08-01

    Present study was conducted to investigate the effect of gamma radiations on the quality and shelf life of strawberries. The aim of this study was to evaluate gamma radiation doses in range of 0.3- 1.5 kGy. The irradiated strawberries were stored in ambient (temperature 25 +- 2oC, RH 70 %) and refrigerated (3 +-1oC, RH 80%) conditions. In samples treated with dose 1.2-1.5 kGy no decay was recorded up to 9 days of ambient conditions. Under refrigerated conditions, strawberry samples of unirradiated and irradiated in the range of 0.3-0.9 kGy started decaying after 14 days of storage. No decay was observed in the samples treated with 1.2-1.5 kGy up to 28 days of refrigerated storage. Dose of 1.2 kGy was significantly effective in reducing the weight loss and in maintaining the higher overall acceptability under both the storage conditions compared to the other treatments. This dose also proved effective in retention of significantly higher levels of total sugars compared to the other treatments. Thus, it was established that irradiating strawberries with dose of 1.2 kGy can prove beneficial in facilitating the marketing of the fruit to distant places other than the local markets, thereby benefiting the growers.

  15. Capstone Depleted Uranium Aerosol Biokinetics, Concentrations, and Doses

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guilmette, Raymond A.; Miller, Guthrie; Parkhurst, MaryAnn

    2009-02-26

    One of the principal goals of the Capstone Depleted Uranium (DU) Aerosol Study was to quantify and characterize DU aerosols generated inside armored vehicles by perforation with a DU penetrator. This study consequently produced a database in which the DU aerosol source terms were specified both physically and chemically for a variety of penetrator-impact geometries and conditions. These source terms were used to calculate radiation doses and uranium concentrations for various scenarios as part of the Capstone DU Human Health Risk Assessment (HHRA). This paper describes the scenario-related biokinetics of uranium, and summarizes intakes, chemical concentrations to the organs, andmore » E(50) and HT(50) for organs and tissues based on exposure scenarios for personnel in vehicles at the time of perforation as well as for first responders. For a given exposure scenario (duration time and breathing rates), the range of DU intakes among the target vehicles and shots was not large, about a factor of 10, with the lowest being from a ventilated operational Abrams tank and the highest being for an unventilated Abrams with DU penetrator perforating DU armor. The ranges of committed effective doses were more scenario-dependent than were intakes. For example, the largest range, a factor of 20, was shown for scenario A, a 1-min exposure, whereas, the range was only a factor of two for the first-responder scenario (E). In general, the committed effective doses were found to be in the tens of mSv. The risks ascribed to these doses are discussed separately.« less

  16. SU-E-T-541: Bolus Effect of Thermoplastic Masks in IMRT and VMAT Head and Neck Treatments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhen, H; Nedzi, L; Chen, S

    2014-06-01

    Purpose: To quantitatively evaluate the bolus effect of thermoplalstic mask on patient skin dose during multi-field IMRT and VMAT treatment. Methods: The clinically approved target contours for five head and neck patients were deformably registered to an anthropomorphic Rando phantom. Two plans: Multifield IMRT plan with 7-9 beams and VMAT plan with 2-4 arcs were created for each patient following same dose constraints. 3mm skin was excluded from PTVs but not constrained during optimization. The prescription dose was 200-220 cGy/fraction. A thermoplastic head and shoulder mask was customized for the Rando phantom. Each plan was delivered to the phantom twicemore » with and without mask. During each delivery, two rectangular strips of EBT3 films (1cm x 6.8cm) were placed across the anterior upper and lower neck near PTVs to measure the surface dose. For consistency films were positioned at same locations for same patient. A total of 8 film strips were obtained for each patient. Film dose was calibrated in the range of 0-400cGy on the day of plan delivery. For dose comparison 3 regions of interests (ROIs) of 1×1 cm{sup 2} were selected at left, right and middle part of each film, resulting in 6 point doses at each plan delivery. Results: The films without mask show relatively uniform dose distribution while those with mask clearly show mesh pattern of mask, usually indicating an increase in skin dose. On average the increase in skin dose over all ROIs with mask was 31.9%(±14.8%) with a range of 11.4%- 58.4%. There is no statistically significant difference (p=0.44) between skin dose increase in VMAT (30.8%±15.3%) and IMRT delivery (33.0%±14.9%). Conclusion: Thermoplastic immobilization masks increase surface dose for HN patient by around 30%. The magnitude is comparable between multi-field IMRT and VMAT. Radiochromic EBT3 film serves as an effective tool to quantify bolus effect.« less

  17. Estimation of annual effective dose due to natural radioactive elements in ingestion of foodstuffs in tin mining area of Jos-Plateau, Nigeria.

    PubMed

    Jibiri, N N; Farai, I P; Alausa, S K

    2007-01-01

    Soils and food crops from a former tin mining location in a high background radiation area on the Jos-Plateau, Nigeria were collected and analyzed by gamma spectrometry to measure their contents of 40K, 238U and 232Th. As well as collecting samples, in situ dose rates on farms were measured using a precalibrated survey meter. Activity concentrations determined in food crops were compared with the local food derivatives or diets to investigate the possible removal or addition of radionuclides during food preparation by cooking or other means. Potassium-40 was found to contribute the highest activity in all the food products. The activity concentration of 40K, 238U and 232Th in local prepared diets ranged between 60 and 494 Bq kg-1, between BDL and 48 Bq kg-1 and between BDL and 17 Bq kg-1, respectively. The internal effective dose to individuals from the consumption of the food types was estimated on the basis of the measured radionuclide contents in the food crops. It ranged between 0.2 microSv y-1 (beans) and 2164 microSv y-1 (yam) while the annual external gamma effective dose in the farms due to soil radioactivity ranged between 228 microSv and 4065 microSv.

  18. Effectiveness of Ivermectin and Albendazole against Haemonchus contortus in Sheep in West Java, Indonesia.

    PubMed

    Puspitasari, Silvia; Farajallah, Achmad; Sulistiawati, Erni; Muladno

    2016-02-01

    Administering a half dose of an anthelmintic is a simple method for detecting resistance in parasites infesting small ruminants. When a single anthelmintic fails in native sheep from Indonesia, a combination of anthelmintics from different chemical classes with different modes of action are administered as an alternative parasite-control strategy. This study compared the anthelmintic efficacy of ivermectin (IVM) and albendazole (ABZ) given either separately as a single dose or half dose or co-administered to sheep naturally infected with Haemonchus contortus. Twelve sheep from Bogor, West Java, Indonesia were divided into the following six treatment groups: half-dose IVM, full-dose IVM, half-dose ABZ, full-dose ABZ, combined IVM + ABZ, and control. The treatment efficacy was determined using the faecal egg count reduction test (FECRT) at day 0 (pre-treatment) and post-treatment at days 7, 14, 21, 28, 35, and 42. The efficacies of half-dose IVM, full-dose IVM, half-dose ABZ, full-dose ABZ, and the combination treatment ranged from -1900% to 100%, 99% to 100%, -167% to 100%, -467% to 89%, and -200% to 100%, respectively. The FECRT for the half-dose IVM, half-dose ABZ, full-dose ABZ showed that H. contortus is resistant to half-dose IVM and ABZ. Full-dose IVM was effective against H. contortus. The combined treatment was more effective against H. contortus than ABZ alone.

  19. Effectiveness of Ivermectin and Albendazole against Haemonchus contortus in Sheep in West Java, Indonesia

    PubMed Central

    Puspitasari, Silvia; Farajallah, Achmad; Sulistiawati, Erni; Muladno

    2016-01-01

    Administering a half dose of an anthelmintic is a simple method for detecting resistance in parasites infesting small ruminants. When a single anthelmintic fails in native sheep from Indonesia, a combination of anthelmintics from different chemical classes with different modes of action are administered as an alternative parasite-control strategy. This study compared the anthelmintic efficacy of ivermectin (IVM) and albendazole (ABZ) given either separately as a single dose or half dose or co-administered to sheep naturally infected with Haemonchus contortus. Twelve sheep from Bogor, West Java, Indonesia were divided into the following six treatment groups: half-dose IVM, full-dose IVM, half-dose ABZ, full-dose ABZ, combined IVM + ABZ, and control. The treatment efficacy was determined using the faecal egg count reduction test (FECRT) at day 0 (pre-treatment) and post-treatment at days 7, 14, 21, 28, 35, and 42. The efficacies of half-dose IVM, full-dose IVM, half-dose ABZ, full-dose ABZ, and the combination treatment ranged from −1900% to 100%, 99% to 100%, −167% to 100%, −467% to 89%, and −200% to 100%, respectively. The FECRT for the half-dose IVM, half-dose ABZ, full-dose ABZ showed that H. contortus is resistant to half-dose IVM and ABZ. Full-dose IVM was effective against H. contortus. The combined treatment was more effective against H. contortus than ABZ alone. PMID:27019686

  20. A swinging seesaw as a novel model mechanism for time-dependent hormesis under dose-dependent stimulatory and inhibitory effects: A case study on the toxicity of antibacterial chemicals to Aliivibrio fischeri.

    PubMed

    Sun, Haoyu; Calabrese, Edward J; Zheng, Min; Wang, Dali; Pan, Yongzheng; Lin, Zhifen; Liu, Ying

    2018-08-01

    Hormesis occurs frequently in broadly ranging biological areas (e.g. plant biology, microbiology, biogerontology), toxicology, pharmacology and medicine. While numerous mechanisms (e.g. receptor and pathway mediated pathway responses) account for stimulatory and inhibitory features of hormetic dose responses, the vast majority emphasizes the inclusion of many doses but only one timepoint or use of a single optimized dose that is assessed over a broad range of timepoints. In this paper, a toxicity study was designed using a large number of properly spaced doses with responses determined over a large number of timepoints, which could help us reveal the underlying mechanism of hormesis. We present the results of a dose-time-response study on hormesis using five antibacterial chemicals on the bioluminescence of Aliivibrio fischeri, measuring expression of protein mRNA based on quorum sensing, simulating bioluminescent reaction and analyzing toxic actions of test chemicals. The findings show dose-time-dependent responses conforming to the hormetic dose-response model, while revealing unique response dynamics between agent induced stimulatory and inhibitory effects within bacterial growth phase dynamics. These dynamic dose-time features reveal a type of biological seesaw model that integrates stimulatory and inhibitory responses within unique growth phase, dose and time features, which has faultlessly explained the time-dependent hormetic phenomenon induced by five antibacterial chemicals (characterized by low-dose stimulation and high-dose inhibition). This study offers advances in understanding cellular dynamics, the biological integration of diverse and opposing responses and their role in evolutionary adaptive strategies to chemicals, which can provide new insight into the mechanistic investigation of hormesis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Organ and effective doses in newborn patients during helical multislice computed tomography examination

    NASA Astrophysics Data System (ADS)

    Staton, Robert J.; Lee, Choonik; Lee, Choonsik; Williams, Matt D.; Hintenlang, David E.; Arreola, Manuel M.; Williams, Jonathon L.; Bolch, Wesley E.

    2006-10-01

    In this study, two computational phantoms of the newborn patient were used to assess individual organ doses and effective doses delivered during head, chest, abdomen, pelvis, and torso examinations using the Siemens SOMATOM Sensation 16 helical multi-slice computed tomography (MSCT) scanner. The stylized phantom used to model the patient anatomy was the revised ORNL newborn phantom by Han et al (2006 Health Phys.90 337). The tomographic phantom used in the study was that developed by Nipper et al (2002 Phys. Med. Biol. 47 3143) as recently revised by Staton et al (2006 Med. Phys. 33 3283). The stylized model was implemented within the MCNP5 radiation transport code, while the tomographic phantom was incorporated within the EGSnrc code. In both codes, the x-ray source was modelled as a fan beam originating from the focal spot at a fan angle of 52° and a focal-spot-to-axis distance of 57 cm. The helical path of the source was explicitly modelled based on variations in collimator setting (12 mm or 24 mm), detector pitch and scan length. Tube potentials of 80, 100 and 120 kVp were considered in this study. Beam profile data were acquired using radiological film measurements on a 16 cm PMMA phantom, which yielded effective beam widths of 14.7 mm and 26.8 mm for collimator settings of 12 mm and 24 mm, respectively. Values of absolute organ absorbed dose were determined via the use of normalization factors defined as the ratio of the CTDI100 measured in-phantom and that determined by Monte Carlo simulation of the PMMA phantom and ion chamber. Across various technique factors, effective dose differences between the stylized and tomographic phantoms ranged from +2% to +9% for head exams, -4% to -2% for chest exams, +8% to +24% for abdominal exams, -16% to -12% for pelvic exams and -7% to 0% for chest-abdomen-pelvis (CAP) exams. In many cases, however, relatively close agreement in effective dose was accomplished at the expense of compensating errors in individual organ dose. Per cent differences in organ dose between the stylized and tomographic phantoms at 120 kVp and 12 mm collimator setting ranged from -25% (skin) to +164% (muscle) for head exams, -92% (thyroid) to +98% (ovaries) for chest exams, -144% (uterus) to +112% (ovaries) for abdominal exams, -98% (SI wall) to +20% (thymus) for pelvic exams and -60% (extrathoracic airways) to +13% (ovaries) for CAP exams. Better agreement was seen between the two phantom types for organs entirely within the scan field. In these cases, corresponding per cent differences in organ absorbed dose did not vary more than 17%. For all scans, the effective dose was found to range approximately 1-13 mSv across the scan parameters and scan regions. The largest effective dose occurred for CAP scans at 120 kVp.

  2. Characterization of Thymol blue Radiochromic dosimeters for high dose applications

    NASA Astrophysics Data System (ADS)

    Aldweri, Feras M.; Abuzayed, Manar H.; Al-Ajaleen, Musab S.; Rabaeh, Khalid A.

    2018-03-01

    Thymol blue (TB) solutions and Thymol blue Polyvinyl Alcohol (TB-PVA) films have been introduced as Radiochromic dosimeter for high dose applications. The dosimeters were irradiated with gamma ray (60Co source) from 5 to 30 kGy for film, and from 0.150 kGy to 4 kGy for solution. The optical density of unirradiated and irradiated TB solution as well as TB-PVA film dosimeters were studied in terms of absorbance at 434 nm using UV/VIS spectrophotometer. The effects of scan temperature, light pre-gamma irradiation, dose rate, relative humidity and stability of the absorbance of solutions and films after irradiation were investigated. We found the dose sensitivity of TB solution and TB-PVA film dosimeters increases significantly with increases of the absorbed dose as well as with the increases of TB dye concentrations. The useful dose range of developed TB solutions and TB-PVA films dosimeters is in the range 0.125-1 kGy and of 5-20 kGy, respectively.

  3. The correlation between elongation at break and thermal decomposition of aged EPDM cable polymer

    NASA Astrophysics Data System (ADS)

    Šarac, T.; Devaux, J.; Quiévy, N.; Gusarov, A.; Konstantinović, M. J.

    2017-03-01

    The effect of simultaneous thermal and gamma irradiation ageing on the mechanical and physicochemical properties of industrial EPDM was investigated. Accelerated ageing, covering a wide range of dose rates, doses and temperatures, was preformed in stagnant air on EPDM polymer samples extracted from the cables in use in the Belgian nuclear power plants. The mechanical properties, ultimate tensile stress and elongation at break, are found to exhibit the strong dependence on the dose, ageing temperature and dose rate. The thermal decomposition of aged polymer is observed to be the dose dependent when thermogravimetry test is performed under air atmosphere. No dose dependence is observed when thermal decomposition is performed under nitrogen atmosphere. The thermal decomposition rates are found to fully mimic the reduction of elongation at break for all dose rates and ageing temperatures. This effect is argued to be the result of thermal and radiation mediated oxidation degradation process.

  4. Safety, pharmacokinetics, and pharmacodynamics of BMS-986142, a novel reversible BTK inhibitor, in healthy participants.

    PubMed

    Lee, Sun Ku; Xing, Jun; Catlett, Ian M; Adamczyk, Robert; Griffies, Amber; Liu, Ang; Murthy, Bindu; Nowak, Miroslawa

    2017-06-01

    BMS-986142 is an oral, small-molecule reversible inhibitor of Bruton's tyrosine kinase. The main objectives of our phase I studies were to characterize the safety and tolerability, pharmacokinetics, and pharmacodynamics of BMS-986142 in healthy participants, and to investigate the potential for the effect of BMS-986142 on the PK of methotrexate (MTX) in combination. In a combined single ascending dose and multiple ascending dose study, the safety, pharmacokinetics, and pharmacodynamics of BMS-986142 were assessed in healthy non-Japanese participants following administration of a single dose (5-900 mg) or multiple doses (25-350 mg, once daily for 14 days). In a drug-drug interaction study, the effect of BMS-986142 (350 mg, once daily for 5 days) on the single-dose pharmacokinetics of MTX (7.5 mg) was assessed in healthy participants. BMS-986142 was generally well tolerated, alone and in combination with MTX. BMS-986142 was rapidly absorbed with peak concentrations occurring within 2 h, and was eliminated with a mean half-life ranging from 7 to 11 h. Exposure of BMS-986142 appeared dose proportional within the dose ranges tested. A dose- and concentration-dependent inhibition of CD69 expression was observed following administration of BMS-986142. BMS-986142 did not affect the pharmacokinetics of MTX. BMS-986142 was well tolerated at the doses tested, had pharmacokinetic and pharmacodynamic profiles which support once-daily dosing, and can be coadministered with MTX without the pharmacokinetic interaction of BMS-986142 on MTX.

  5. Sublingual buprenorphine is effective in the treatment of chronic pain syndrome.

    PubMed

    Malinoff, Herbert L; Barkin, Robert L; Wilson, Geoffrey

    2005-01-01

    Many patients with chronic pain have less than optimal therapeutic outcomes after prolonged treatment with opiate analgesics. Worsening of pain perception, functional capacity, and mood often result. Medical detoxification is often undertaken in this situation. Ninety-five consecutive patients (49 men and 46 women; age range, 26-84) with chronic noncancer pain (maldynia) were referred by local pain clinics for detoxification from long-term opiate analgesic (LTOA) therapy. All patients had failed treatment as manifest by increasing pain levels, worsening functional capacity, and, in 8%, the emergence of opiate addiction. Length of prior LTOA therapy ranged from 1.5 to 27 years (mean, 8.8 years). After a minimum of 12 hours of abstinence from all opiate analgesics, patients were given low doses of sublingual (SL) buprenorphine or buprenorphine/naloxone (Reckitt Benckiser). Maintenance dosing was individualized to treat chronic pain. Daily SL dose of buprenorphine ranged from 4 to 16 mg (mean, 8 mg) in divided doses. Mean duration of treatment is 8.8 months (range, 2.4-16.6 months). At clinic appointments, patients were assessed for pain reports, functional capacity, and mood inventory. Eighty-six percent of patients experienced moderate to substantial relief of pain accompanied by both improved mood and functioning. Patient and family satisfaction was robust. Only 6 patients discontinued therapy secondary to side effects and/or exacerbation of pain. In this open-label study, SL buprenorphine and buprenorphine/naloxone were well tolerated and safe and appeared to be effective in the treatment of chronic pain patients refractory to LTOA.

  6. Cost-effectiveness of the Adjuvanted Herpes Zoster Subunit Vaccine in Older Adults.

    PubMed

    Le, Phuc; Rothberg, Michael B

    2018-02-01

    The live attenuated herpes zoster vaccine (ZVL) is recommended for immunocompetent adults 60 years or older, but the efficacy wanes with age and over time. A new adjuvanted herpes zoster subunit vaccine (HZ/su) has higher efficacy but might be more expensive. The choice of vaccines depends on their relative values. To assess the cost-effectiveness of HZ/su. Markov decision model with transition probabilities based on the US medical literature. Participants were immunocompetent adults 60 years or older. Data were derived from participant groups ranging in number from less than 100 to more than 30 000 depending on the variable assessed. The study dates were July 1 to 31, 2017. No vaccination, ZVL (single dose), and HZ/su (2-dose series) vaccine administered at different ages. Total costs and quality-adjusted life-years (QALYs) were estimated. Based on randomized clinical trial data, at a price of $280 per series ($140 per dose), HZ/su was more effective and less expensive than ZVL at all ages. The incremental cost-effectiveness ratios compared with no vaccination ranged from $20 038 to $30 084 per QALY, depending on vaccination age. The finding was insensitive to variations in most model inputs other than the vaccine price and certain combinations of low adherence rate with a second dose and low efficacy of a single dose of HZ/su. At the current ZVL price ($213 per dose), HZ/su had lower overall costs than ZVL up to a price of $350 per 2-dose series. In probabilistic sensitivity analysis, HZ/su had 73% probability of being cost-effective for 60-year-olds at $50 000 per QALY. Under conservative assumptions, at a price of $280 per series ($140 per dose), HZ/su would cost less than ZVL and has a high probability of offering good value.

  7. Negative Allosteric Modulators of Metabotropic Glutamate Receptors Subtype 5 in Addiction: a Therapeutic Window

    PubMed Central

    2016-01-01

    Background: Abundant evidence at the anatomical, electrophysiological, and molecular levels implicates metabotropic glutamate receptor subtype 5 (mGluR5) in addiction. Consistently, the effects of a wide range of doses of different mGluR5 negative allosteric modulators (NAMs) have been tested in various animal models of addiction. Here, these studies were subjected to a systematic review to find out if mGluR5 NAMs have a therapeutic potential that can be translated to the clinic. Methods: Literature on consumption/self-administration and reinstatement of drug seeking as outcomes of interest published up to April 2015 was retrieved via PubMed. The review focused on the effects of systemic (i.p., i.v., s.c.) administration of the mGluR5 NAMs 3-((2-Methyl-4-thiazolyl)ethynyl)pyridine (MTEP) and 2-Methyl-6-(phenylethynyl)pyridine (MPEP) on paradigms with cocaine, ethanol, nicotine, and food in rats. Results: MTEP and MPEP were found to reduce self-administration of cocaine, ethanol, and nicotine at doses ≥1mg/kg and 2.5mg/kg, respectively. Dose-response relationship resembled a sigmoidal curve, with low doses not reaching statistical significance and high doses reliably inhibiting self-administration of drugs of abuse. Importantly, self-administration of cocaine, ethanol, and nicotine, but not food, was reduced by MTEP and MPEP in the dose range of 1 to 2mg/kg and 2.5 to 3.2mg/kg, respectively. This dose range corresponds to approximately 50% to 80% mGluR5 occupancy. Interestingly, the limited data found in mice and monkeys showed a similar therapeutic window. Conclusion: Altogether, this review suggests a therapeutic window for mGluR5 NAMs that can be translated to the treatment of substance-related and addictive disorders. PMID:26802568

  8. Rapid Inpatient Titration of Intravenous Treprostinil for Pulmonary Arterial Hypertension: Safe and Tolerable.

    PubMed

    El-Kersh, Karim; Ruf, Kathryn M; Smith, J Shaun

    There is no standard protocol for intravenous treprostinil dose escalation. In most cases, slow up-titration is performed in the outpatient setting. However, rapid up-titration in an inpatient setting is an alternative that provides opportunity for aggressive treatment of common side effects experienced during dose escalation. In this study, we describe our experience with inpatient rapid up-titration of intravenous treprostinil. This was a single-center, retrospective study in which we reviewed the data of subjects with pulmonary arterial hypertension treated at our center who underwent inpatient rapid up-titration of intravenous treprostinil. Our treprostinil dose escalation protocol included initiation at 2 ng·kg·min with subsequent up-titration by 1 ng·kg·min every 6 to 8 hours as tolerated by side effects. A total of 16 subjects were identified. Thirteen subjects were treprostinil naive (naive group), and 3 subjects were receiving subcutaneous treprostinil but were hospitalized for further intravenous up-titration of treprostinil dose (nonnaive group). In the naive group, the median maximum dose achieved was 20 ng·kg·min with an interquartile range (IQR) of 20-23 ng·kg·min. The median up-titration interval was 6 days (IQR: 4-9). In the nonnaive group, the median maximum dose achieved was 20 ng·kg·min (range: 17-30). The median up-titration interval was 8.5 days (range: 1.5-11). Overall, the median maximum dose achieved was 20 ng·kg·min (IQR: 20-23.5), and the median up-titration interval was 6 days (IQR: 4.6-9.25), with no reported significant adverse hemodynamic events. In patients with pulmonary arterial hypertension, rapid inpatient titration of intravenous treprostinil is safe and tolerable.

  9. SU-E-T-352: Effects of Skull Attenuation and Missing Backscatter On Brain Dose in HDR Treatment of the Head with Surface Applicators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cifter, F; Dhou, S; Lewis, J

    2015-06-15

    Purpose: To calculate the effect of lack of backscatter from air and attenuation of bone on dose distributions in brachytherapy surface treatment of head. Existing treatment planning systems based on TG43 do not account for heterogeneities, and thus may overestimate the dose to the brain. While brachytherapy generally has rapid dose falloff, the dose to the deeper tissues (in this case, the brain) can become significant when treating large curved surfaces. Methods: Applicator geometries representing a range of clinical cases were simulated in MCNP5. An Ir-192 source was modeled using the energy spectrum presented by TG-43. The head phantom wasmore » modeled as a 7.5-cm radius water sphere, with a 7 -mm thick skull embedded 5-mm beneath the surface. Dose values were calculated at 20 points inside the head, in which 10 of them were on the central axis and the other 10 on the axis connecting the central of the phantom with the second to last source from the applicator edge. Results: Central and peripheral dose distributions for a range of applicator and head sizes are presented. The distance along the central axis at which the dose falls to 80% of the prescribed dose (D80) was 7 mm for a representative small applicator and 9 mm for a large applicator. Corresponding D50 and D30 for the same small applicator were 17 mm and 32 mm respectively. D50 and D30 for the larger applicator were 32 mm and 60 mm respectively. These results reflect the slower falloff expected for larger applicators on a curved surface. Conclusion: Our results can provide guidance for clinicians to calculate the dose reduction effect due to bone attenuation and the lack of backscatter from air to estimate the brain dose for the HDR treatments of surface lesions.« less

  10. Iodine kinetics and dosimetry in the salivary glands during repeated courses of radioiodine therapy for thyroid cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, B.; Huang, R.; Kuang, A.

    2011-10-15

    Purpose: The present study was conducted to investigate salivary iodine kinetics and dosimetry during repeated courses of radioiodine ({sup 131}I) therapy for differentiated thyroid cancer (DTC). Such data could provide a better understanding of the mechanisms of {sup 131}I induced salivary toxicity and help to develop appropriate methods to reduce this injury. Methods: Seventy-eight consecutive DTC patients (mean age 45 {+-} 17 years, 60%, female) undergoing {sup 131}I therapy for remnant ablation or metastatic tumors were prospectively recruited. Planar quantitative scintigraphy of head-neck images was serially acquired after administration of 2.9-7.4 GBq of {sup 131}I to assess kinetics in themore » salivary glands of patients. Salivary absorbed doses were calculated based on the schema of Medical Internal Radiation Dosimetry. Results: The maximum uptakes in percentage of administered {sup 131}I activity per kilogram of gland tissue (%/kg) were 12.9% {+-} 6.5%/kg (range, 0.4%-37.3%/kg) and 12.3% {+-} 6.2%/kg (range, 0.4%-35.1%/kg) for the parotid and submandibular glands, respectively. Statistically significant correlations of maximum uptake versus cumulative activity (r = -0.74, P < 0.01, for the parotid glands; r = -0.71, P < 0.01, for the submandibular glands) and treatment cycle (P < 0.001, for both gland types) were found. The effective half-lives of {sup 131}I in the parotid and submandibular glands were 9.3 {+-} 3.5 h (range, 1.5-19.8 h) and 8.6 {+-} 3.2 h (range, 0.8-18.0 h), respectively. A statistically significant correlation was observed between effective half-life with cumulative activity (r = 0.37, P < 0.01) and treatment cycle (P = 0.03) only for the parotid glands. The calculated absorbed doses were 0.20 {+-} 0.10 mGy/MBq (range, 0.01-0.92 mGy/MBq) and 0.25 {+-} 0.09 mGy/MBq (range, 0.01-1.52 mGy/MBq) for the parotid and submandibular glands, respectively. The photon contribution to the salivary absorbed dose was minimal in relation to the beta dose contribution. Photon-absorbed dose fractions of total absorbed dose were 4.9% {+-} 1.3% (range, 1.1%-8.7%) and 3.7% {+-} 2.5% (range, 0.8%-7.9%) for the parotid and submandibular glands, respectively. Conclusions: The iodine uptake of salivary glands is continuously reduced during the courses of therapy. The phenomenon of hyper-radiosensitivity may to some extent account for the occurrence of salivary gland hypofunction at very low radiation doses with low dose rates in {sup 131}I therapy. On the other hand, failure to incorporate a nonuniform and preferential uptake by salivary gland ductal cells may result in underestimating the actual dose for the critical tissue. Other methods, including {sup 124}I voxel-based dosimetry, are warranted to further investigate the {sup 131}I-induced salivary gland toxicity.« less

  11. Calculation of organ doses from breast cancer radiotherapy: a Monte Carlo study

    PubMed Central

    Berris, T.; Mazonakis, M.; Stratakis, J.; Tzedakis, A.; Fasoulaki, A.

    2013-01-01

    The current study aimed to: a) utilize Monte Carlo simulation methods for the assessment of radiation doses imparted to all organs at risk to develop secondary radiation induced cancer, for patients undergoing radiotherapy for breast cancer; and b) evaluate the effect of breast size on dose to organs outside the irradiation field. A simulated linear accelerator model was generated. The in‐field accuracy of the simulated photon beam properties was verified against percentage depth dose (PDD) and dose profile measurements on an actual water phantom. Off‐axis dose calculations were verified with thermoluminescent dosimetry (TLD) measurements on a humanoid physical phantom. An anthropomorphic mathematical phantom was used to simulate breast cancer radiotherapy with medial and lateral fields. The effect of breast size on the calculated organ dose was investigated. Local differences between measured and calculated PDDs and dose profiles did not exceed 2% for the points at depths beyond the depth of maximum dose and the plateau region of the profile, respectively. For the penumbral regions of the dose profiles, the distance to agreement (DTA) did not exceed 2 mm. The mean difference between calculated out‐of‐field doses and TLD measurements was 11.4%±5.9%. The calculated doses to peripheral organs ranged from 2.32 cGy up to 161.41 cGy depending on breast size and thus the field dimensions applied, as well as the proximity of the organs to the primary beam. An increase to the therapeutic field area by 50% to account for the large breast led to a mean organ dose elevation by up to 85.2% for lateral exposure. The contralateral breast dose ranged between 1.4% and 1.6% of the prescribed dose to the tumor. Breast size affects dose deposition substantially. PACS numbers: 87.10.rt, 87.56.bd, 87.53.Bn, 87.55.K‐, 87.55.ne, 87.56.jf, 87.56.J‐ PMID:23318389

  12. Dosimetric properties of a proton beamline dedicated to the treatment of ocular disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slopsema, R. L., E-mail: rslopsema@floridaproton.org; Mamalui, M.; Yeung, D.

    2014-01-15

    Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systemsmore » and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong dependence on range (up to 4%/mm). A linear increase in dose/MU as a function of instantaneous MU rate is observed. The dose/MU model describes the measurements with an accuracy of ±2%. Neutron dose is found to be 146 ± 102 μSv/Gy at the contralateral eye and 19 ± 13 μSv/Gy at the chest. Conclusions: Measurements show the proton eyeline meets the requirements to effectively treat ocular disease.« less

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Slopsema, R. L., E-mail: rslopsema@floridaproton.org; Mamalui, M.; Yeung, D.

    Purpose: A commercial proton eyeline has been developed to treat ocular disease. Radiotherapy of intraocular lesions (e.g., uveal melanoma, age-related macular degeneration) requires sharp dose gradients to avoid critical structures like the macula and optic disc. A high dose rate is needed to limit patient gazing times during delivery of large fractional dose. Dose delivery needs to be accurate and predictable, not in the least because current treatment planning algorithms have limited dose modeling capabilities. The purpose of this paper is to determine the dosimetric properties of a new proton eyeline. These properties are compared to those of existing systemsmore » and evaluated in the context of the specific clinical requirements of ocular treatments. Methods: The eyeline is part of a high-energy, cyclotron-based proton therapy system. The energy at the entrance of the eyeline is 105 MeV. A range modulator (RM) wheel generates the spread-out Bragg peak, while a variable range shifter system adjusts the range and spreads the beam laterally. The range can be adjusted from 0.5 up to 3.4 g/cm{sup 2}; the modulation width can be varied in steps of 0.3 g/cm{sup 2} or less. Maximum field diameter is 2.5 cm. All fields can be delivered with a dose rate of 30 Gy/min or more. The eyeline is calibrated according to the IAEA TRS-398 protocol using a cylindrical ionization chamber. Depth dose distributions and dose/MU are measured with a parallel-plate ionization chamber; lateral profiles with radiochromic film. The dose/MU is modeled as a function of range, modulation width, and instantaneous MU rate with fit parameters determined per option (RM wheel). Results: The distal fall-off of the spread-out Bragg peak is 0.3 g/cm{sup 2}, larger than for most existing systems. The lateral penumbra varies between 0.9 and 1.4 mm, except for fully modulated fields that have a larger penumbra at skin. The source-to-axis distance is found to be 169 cm. The dose/MU shows a strong dependence on range (up to 4%/mm). A linear increase in dose/MU as a function of instantaneous MU rate is observed. The dose/MU model describes the measurements with an accuracy of ±2%. Neutron dose is found to be 146 ± 102 μSv/Gy at the contralateral eye and 19 ± 13 μSv/Gy at the chest. Conclusions: Measurements show the proton eyeline meets the requirements to effectively treat ocular disease.« less

  14. Acute cognitive effects of high doses of dextromethorphan relative to triazolam in humans

    PubMed Central

    Carter, Lawrence P.; Reissig, Chad J.; Johnson, Matthew W.; Klinedinst, Margaret A.; Griffiths, Roland R.

    2012-01-01

    BACKGROUND Although concerns surrounding high-dose dextromethorphan (DXM) abuse have recently increased, few studies have examined the acute cognitive effects of high doses of DXM. The aim of this study was to compare the cognitive effects of DXM with those of triazolam and placebo. METHODS Single, acute, oral doses of DXM (100, 200, 300, 400, 500, 600, 700, 800 mg/70 kg), triazolam (0.25, 0.5 mg /70 kg), and placebo were administered p.o. to twelve healthy volunteers with histories of hallucinogen use, under double-blind conditions, using an ascending dose run-up design. Effects on cognitive performance were examined at baseline and after drug administration for up to 6 hours. RESULTS Both triazolam and DXM produced acute impairments in attention, working memory, episodic memory, and metacognition. Impairments observed following doses of 100-300 mg/70 kg DXM were generally smaller in magnitude than those observed after 0.5 mg/70 kg triazolam. Doses of DXM that impaired performance to the same extent as triazolam were in excess of 10-30 times the therapeutic dose of DXM. CONCLUSION The magnitude of the doses required for these effects and the absence of effects on some tasks within the 100-300 mg/70 kg dose range of DXM, speak to the relatively broad therapeutic window of over-the-counter DXM preparations when used appropriately. However, the administration of supratherapeutic doses of DXM resulted in acute cognitive impairments on all tasks that were examined. These findings are likely relevant to cases of high-dose DXM abuse. PMID:22989498

  15. Radiation exposure of the radiologist's eye lens during CT-guided interventions.

    PubMed

    Heusch, Philipp; Kröpil, Patric; Buchbender, Christian; Aissa, Joel; Lanzman, Rotem S; Heusner, Till A; Ewen, Klaus; Antoch, Gerald; Fürst, Günther

    2014-02-01

    In the past decade the number of computed tomography (CT)-guided procedures performed by interventional radiologists have increased, leading to a significantly higher radiation exposure of the interventionalist's eye lens. Because of growing concern that there is a stochastic effect for the development of lens opacification, eye lens dose reduction for operators and patients should be of maximal interest. To determine the interventionalist's equivalent eye lens dose during CT-guided interventions and to relate the results to the maximum of the recommended equivalent dose limit. During 89 CT-guided interventions (e.g. biopsies, drainage procedures, etc.) measurements of eye lens' radiation doses were obtained from a dedicated dosimeter system for scattered radiation. The sensor of the personal dosimeter system was clipped onto the side of the lead glasses which was located nearest to the CT gantry. After the procedure, radiation dose (µSv), dose rate (µSv/min) and the total exposure time (s) were recorded. For all 89 interventions, the median total exposure lens dose was 3.3 µSv (range, 0.03-218.9 µSv) for a median exposure time of 26.2 s (range, 1.1-94.0 s). The median dose rate was 13.9 µSv/min (range, 1.1-335.5 µSv/min). Estimating 50-200 CT-guided interventions per year performed by one interventionalist, the median dose of the eye lens of the interventional radiologist does not exceed the maximum of the ICRP-recommended equivalent eye lens dose limit of 20 mSv per year.

  16. Nuclear-weapon-effect research at PSR (Pacific-Sierra Research Corporation) - 1983. Volume 10. Symptomatology of acute radiation effects in humans after exposure to doses of 75 to 4500 rads (cGy) free-in-air. Final technical report, 27 October 1982-30 November 1983

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baum, S.J.; Young, R.W.; Anno, G.H.

    1984-08-31

    This report distills from available data descriptions of typical human symptoms in reaction to prompt ionizing radiation in the dose range 75 to 4500 rads (cGy) free-in-air. The descriptions correlate symptoms with dose and time over the acute post-exposure period of six weeks. Their purpose is to provide an empirical base for estimating combat troop performance after a nuclear weapon attack. The dose range of interest is subdivided into eight subranges associated with important pathophysiological events. For each subrange, the signs and symptoms manifested by an exposed population are estimated--symptom onset, severity, duration, and incidence. The early or prodromal phasemore » of radiation sickness begins about 2 to 4 hrs after doses of 300 to 530 rads (cGy). Onset time diminishes with dose, occurring within minutes of exposure to 4500 rads (cGy). Characteristic prodromal symptoms are nausea, vomiting, anorexia, and diarrhea. The prodromal phase lasts from several days to a matter of hours, depending on dose. Symptoms of the hemopoietic syndrome are bleeding, fever, infection, and ulceration. Symptoms of the gastrointestinal syndrome are fluid loss, electrolyte imbalance, severe diarrhea, and septicemia.« less

  17. Methamphetamine blood concentrations in human abusers: application to pharmacokinetic modeling.

    PubMed

    Melega, William P; Cho, Arthur K; Harvey, Dennis; Laćan, Goran

    2007-04-01

    Characterization of methamphetamine's (METH) dose-dependent effects on brain neurochemistry may represent a critical component for better understanding the range of resultant behavioral pathologies. Most human studies, however, have assessed only the effects of long term, high dose METH abuse (e.g., greater than 1000 mg/day) in individuals meeting DSM-IV criteria for METH dependence. Yet, for the majority of METH abusers, their patterns of METH exposure that consist of lower doses remain less well-characterized. In this study, blood samples were obtained from 105 individuals detained by police for possible criminal activity and testing positive for stimulants by EMIT assay. METH blood concentrations were subsequently quantified by GC-MS and were predominantly in the low micromolar range (0.1-11.1 microM), with median and mean values of 1.3 microM (0.19 mg/l) and 2 microM (0.3 mg/l), respectively. Pharmacokinetic calculations based on these measured values were used to estimate initial METH body burdens, the median value being 52 mg. Modeling a 52 mg dose for a 4 day-METH maintenance exposure pattern of 4 doses/day at 4 h intervals showed that blood concentrations remained between 1 and 4 microM during this period. Collectively, these data present evidence for a METH exposure pattern distinct from high dose-METH abuse and provide the rationale for assessing potential brain pathology associated with such lower dose-METH exposure.

  18. Evaluation of cytotoxicity and radiation enhancement using 1.9 nm gold particles: potential application for cancer therapy

    PubMed Central

    Butterworth, K T; Coulter, J A; Jain, S; Forker, J; McMahon, S J; Schettino, G; Prise, K M; Currell, F J; Hirst, D G

    2010-01-01

    High atomic number (Z) materials such as gold preferentially absorb kilovoltage x-rays compared to soft tissue and may be used to achieve local dose enhancement in tumours during treatment with ionizing radiation. Gold nanoparticles have been demonstrated as radiation dose enhancing agents in vivo and in vitro. In the present study, we used multiple endpoints to characterize the cellular cytotoxic response of a range of cell lines to 1.9 nm gold particles and measured dose modifying effects following transient exposure at low concentrations. Gold nanoparticles caused significant levels of cell type specific cytotoxicity, apoptosis and increased oxidative stress. When used as dose modifying agents, dose enhancement factors varied between the cell lines investigated with the highest enhancement being 1.9 in AGO-1522B cells at a nanoparticle concentration of 100 μg ml−1. This study shows exposure to 1.9 nm gold particles to induce a range of cell line specific responses including decreased clonogenic survival, increased apoptosis and induction of DNA damage which may be mediated through the production of reactive oxygen species. This is the first study involving 1.9 nm nanometre sized particles to report multiple cellular responses which impact on the radiation dose modifying effect. The findings highlight the need for extensive characterization of responses to gold nanoparticles when assessing dose enhancing potential in cancer therapy. PMID:20601762

  19. Are Recommended Doses of Acetaminophen Effective for Children Aged 2 to 3 Years? A Pharmacokinetic Modeling Answer.

    PubMed

    Abourbih, Daniel Asher; Gosselin, Sophie; Villeneuve, Eric; Kazim, Sara

    2016-01-01

    Acetaminophen (APAP) elixir is a widely used pediatric antipyretic medication. It has been shown that up to 30% of febrile children presenting to a large urban pediatric emergency department received inadequate APAP dosages at home with errors primarily due to age-based dosing. Parental education material in the form of weight-based dosing guides has been proposed; however, validation of current recommended APAP dosages using pharmacokinetic models is needed. This study used a mathematical model of APAP absorption to predict plasma concentrations and to compare them with the range required to reach and achieve antipyresis (10-20 μg/mL). A common APAP preparation (Children's Tylenol Elixir) was tested (children aged 2-3 years, 10.9-15.9 kg). The manufacturer's suggested dose of 160 mg was compared with the standard 10 to 15 mg/kg dose range. The model predicts a peak plasma concentration between 6.38 and 8.55 μg/mL for 10 mg/kg dose and 9.57 and 12.8 μg/mL for 15 mg/kg dose. The manufacturer's suggested dose of 160 mg was tested across the limits of the weight range (10.9-15.9 kg). A peak plasma concentration between 9.36 and 12.6 μg/mL was found for the lower weight limit (10.9 kg child) and 6.42 to 8.61 μg/mL for the upper weight limit (15.9 kg child). With the use of this model, the 10 mg/kg dose does not reach the plasma concentration value for antipyresis (10-20 μg/mL), whereas 15 mg/kg is adequate only if assuming a greater absorption constant. The 160 mg dose is effective only for children weighing 10.9 kg. Individual differences in drug bioavailability, volume of distribution, and absorption/elimination constants undoubtedly exist, and future studies directly measuring plasma APAP concentration and pharmacokinetics are needed. However, these results indicate that dosages for APAP in children should be weight based and manufacturers should review their dosing recommendations.

  20. Comparison of effect of 5 MeV proton and Co-60 gamma irradiation on silicon NPN rf power transistors and N-channel depletion MOSFETs

    NASA Astrophysics Data System (ADS)

    Gnana Prakash, A. P.; Pradeep, T. M.; Hegde, Vinayakprasanna N.; Pushpa, N.; Bajpai, P. K.; Patel, S. P.; Trivedi, Tarkeshwar; Bhushan, K. G.

    2017-12-01

    NPN transistors and N-channel depletion metal oxide semiconductor field effect transistors (MOSFETs) were irradiated with 5 MeV protons and 60Co gamma radiation in the dose ranging from 1 Mrad(Si) to 100 Mrad(Si). The different electrical characteristics of the NPN transistor such as Gummel characteristics, excess base current (ΔIB), dc current gain (hFE), transconductance (gm), displacement damage factor (K) and output characteristics were studied as a function of total dose. The different electrical characteristics of N-channel MOSFETs such as threshold voltage (Vth), density of interface trapped charges (ΔNit), density of oxide trapped charges (ΔNot), transconductance (gm), mobility (µ) and drain saturation current (IDSat) were studied systematically before and after irradiation in the same dose ranges. A considerable increase in the base current (IB) and decrease in the hFE, gm and collector saturation current (ICSat) were observed after irradiation in the case of the NPN transistor. In the N-channel MOSFETs, the ΔNit and ΔNot were found to increase and Vth, gm, µ and IDSat were found to decrease with increase in the radiation dose. The 5 MeV proton irradiation results of both the NPN transistor and N-channel MOSFETs were compared with 60Co gamma-irradiated devices in the same dose ranges. It was observed that the degradation in 5 MeV proton-irradiated devices is more when compared with the 60Co gamma-irradiated devices at higher total doses.

  1. Cyproterone acetate in treatment of precocious puberty.

    PubMed Central

    Kauli, R; Pertzelan, A; Prager-Lewin, R; Grünebaum, M; Laron, Z

    1976-01-01

    Twenty-nine children (23 girls, 6 boys) with precocious puberty were treated with cyproterone acetate for various periods of time ranging from 6 months to 3 years 4 months. They received an oral dose ranging from 70-150 mg/m2 per day, or an intramuscular depot injection once a fortnight or once a month at a dose ranging from 107-230 mg/m2. Both forms of therapy were found to suppress the signs of sexual maturation, but the oral form proved to be superior. Only the younger patients with a bone age under 11 years showed a beneficial effect upon linear growth and bone maturation. No side effects were noted, but additional advantageous effects upon behaviour and sociability were. It is concluded that at present cyproterone acetate by mouth is the drug of choice in the treatment of precocious puberty. The treatment should be initiated as early as possible to attain maximum benefit. PMID:952553

  2. Reference dosimetry using radiochromic film

    PubMed Central

    Girard, Frédéric; Bouchard, Hugo

    2012-01-01

    The objectives of this study are to identify and quantify factors that influence radiochromic film dose response and to determine whether such films are suitable for reference dosimetry. The influence of several parameters that may introduce systematic dose errors when performing reference dose measurements were investigated. The effect of the film storage temperature was determined by comparing the performance of three lots of GAFCHROMIC EBT2 films stored at either 4°C or room temperature. The effect of high (>80%) or low (<20%) relative humidity was also determined. Doses measured in optimal conditions with EBT and EBT2 films were then compared with an A12 ionization chamber measurement. Intensity‐modulated radiation therapy quality controls using EBT2 films were also performed in reference dose. The results obtained using reference dose measurements were compared with those obtained using relative dose measurements. Storing the film at 4°C improves the stability of the film over time, but does not eliminate the noncatalytic film development, seen as a rise in optical density over time in the absence of radiation. Relative humidity variations ranging from 80% to 20% have a strong impact on the optical density and could introduce dose errors of up to 15% if the humidity were not controlled during the film storage period. During the scanning procedure, the film temperature influences the optical density that is measured. When controlling for these three parameters, the dose differences between EBT or EBT2 and the A12 chamber are found to be within ±4% (2σ level) over a dose range of 20–350 cGy. Our results also demonstrate the limitation of the Anisotropic Analytical Algorithm for dose calculation of highly modulated treatment plans. PACS numbers: 87.55.Qr; 87.56.Fc PMID:23149793

  3. Is time to peak effect of neuromuscular blocking agents dependent on dose? Testing the concept of buffered diffusion.

    PubMed

    Proost, J H; Houwertjes, M C; Wierda, J M K H

    2008-07-01

    For neuromuscular blocking agents, an inverse relationship between potency and time to peak effect has been observed. To test the hypothesis that this relationship is due to buffered diffusion, we investigated the influence of dose on time to peak effect. Pharmacokinetic-pharmacodynamic simulations were performed to support the expected relationships between potency, dose, peak effect and time to peak effect. Pigs (20-28 kg body weight) were anaesthetized with ketamine and midazolam, followed by pentobarbital and fentanyl intravenously. Neuromuscular block was measured by stimulating the peroneal nerve supramaximally at 0.1 Hz and measuring the response of the tibialis anterior muscle mechanomyographically. After an initial dose to establish the individual ED90 of a neuromuscular blocking agent (rocuronium, vecuronium, pipecuronium or d-tubocurarine), five different doses of the same compound were administered to each animal, aiming at 20%, 40%, 60%, 75% or 90% block, in a random order. Doses were given 45 min after complete recovery of the twitch response. For rocuronium and pipecuronium, time to peak effect increased with dose, whereas dose did not affect time to peak effect of vecuronium and d-tubocurarine. Simulations predict that time to peak effect decreases with dose if buffered diffusion is taken into account. The results suggest that buffered diffusion does not play a dominant role in the time to peak effect of neuromuscular blocking agents. Therefore it is unlikely that the observed inverse relationship between potency and time to peak effect of neuromuscular blocking agents in the clinical range is due to buffered diffusion.

  4. Oxcarbazepine: a new drug in the management of intractable trigeminal neuralgia.

    PubMed Central

    Zakrzewska, J M; Patsalos, P N

    1989-01-01

    The efficacy and tolerability of oxcarbazepine, a keto derivative of carbamazepine, has been assessed in six patients (two males, four females; mean age 61 years, range 42-77), with trigeminal neuralgia refractory to carbamazepine therapy, over a period of 6 months. An excellent therapeutic response to oxcarbazepine was seen in all patients with pain control correlating well with serum drug concentrations of oxcarbazepine and its primary active metabolite 10-OH-carbazepine. Onset of the effect was observed within 24 hours in all cases. An overall serum therapeutic concentration range, in the six patients, of 50-110 mumol/l of 10-OH-carbazepine corresponding to a daily effective dose range of 1200-2400 mg (14.6-35.6 mg/kg body weight) oxcarbazepine, was observed. There was a significant correlation between oxcarbazepine dose and serum oxcarbazepine (r = 0.695, p less than 0.05) and 10-OH-carbazepine (r = 0.957, p less than 0.001) concentrations. Oxcarbazepine was well tolerated and no significant side effects were identified, though a mild hyponatraemia was observed during high doses (greater than 28 and greater than 35 mg/kg/day) in two patients. It is concluded that oxcarbazepine has potent antineuralgic properties in the absence of significant side effects and therefore may be useful in the management of intractable trigeminal neuralgia. Images PMID:2738589

  5. Characterization of Changes in Gene Expression and Biochemical Pathways at Low Levels of Benzene Exposure

    PubMed Central

    Thomas, Reuben; Hubbard, Alan E.; McHale, Cliona M.; Zhang, Luoping; Rappaport, Stephen M.; Lan, Qing; Rothman, Nathaniel; Vermeulen, Roel; Guyton, Kathryn Z.; Jinot, Jennifer; Sonawane, Babasaheb R.; Smith, Martyn T.

    2014-01-01

    Benzene, a ubiquitous environmental pollutant, causes acute myeloid leukemia (AML). Recently, through transcriptome profiling of peripheral blood mononuclear cells (PBMC), we reported dose-dependent effects of benzene exposure on gene expression and biochemical pathways in 83 workers exposed across four airborne concentration ranges (from <1 ppm to >10 ppm) compared with 42 subjects with non-workplace ambient exposure levels. Here, we further characterize these dose-dependent effects with continuous benzene exposure in all 125 study subjects. We estimated air benzene exposure levels in the 42 environmentally-exposed subjects from their unmetabolized urinary benzene levels. We used a novel non-parametric, data-adaptive model selection method to estimate the change with dose in the expression of each gene. We describe non-parametric approaches to model pathway responses and used these to estimate the dose responses of the AML pathway and 4 other pathways of interest. The response patterns of majority of genes as captured by mean estimates of the first and second principal components of the dose-response for the five pathways and the profiles of 6 AML pathway response-representative genes (identified by clustering) exhibited similar apparent supra-linear responses. Responses at or below 0.1 ppm benzene were observed for altered expression of AML pathway genes and CYP2E1. Together, these data show that benzene alters disease-relevant pathways and genes in a dose-dependent manner, with effects apparent at doses as low as 100 ppb in air. Studies with extensive exposure assessment of subjects exposed in the low-dose range between 10 ppb and 1 ppm are needed to confirm these findings. PMID:24786086

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giantsoudi, D; Adams, J; MacDonald, S

    Purpose: In proton radiation therapy of posterior fossa tumors, to spare other sensitive structures, the preferred beam geometry results in placing the treatment field distal edge within or just beyond the brainstem, including in at least partially in the treatment volume. Concerns for brainstem toxicity are increased and a controversy exists as to weather the beam’s distal edge should be placed within the brainstem or beyond it, to avoid elevated linear energy transfer (LET) and relative biological effectiveness (RBE) within the brainstem. The dosimetric efficacy of these techniques was examined, accounting for LET- and dose-dependent variable RBE distributions. Methods: Threemore » treatment planning techniques were applied in six ependymoma cases: (a) three-field dose-sparing, with beams’ distal edge within the brainstem; (b) three-field LET-sparing, using same beam directions as (a) but extended field ranges beyond the brainstem; (c) two-posterior-oblique LET-sparing, with extended ranges as (b). Monte Carlo calculated dose, LET and RBE-weighted dose distributions were compared. Results: Lower LET values in the brainstem were accompanied by higher median dose: 53.7 Gy[RBE] and 54.3 Gy[RBE] for techniques (b) and (c) versus 52.1 Gy[RBE] for (a). Accounting for variable RBE, a 15% increase of the brainstem volume receiving at least 60 Gy[RBE] was observed for technique (c) versus (a). Maximum variable-RBE-weighted brainstem dose was comparable for all techniques. Conclusion: Extending the treatment beam range beyond the brainstem, significantly increased its volume receiving high dose radiation, even when accounting for the decreased LET values. The dosimetric benefits of techniques limiting the brainstem dose may outweigh the impact of LET reduction achieved through this technique, especially since clinical consequences of increased LET at the end of range have not been proven yet.« less

  7. The Biological Effectiveness of Different Radiation Qualities for the Induction of Chromosome Damage in Human Lymphocytes

    NASA Technical Reports Server (NTRS)

    Hada, M.; George, K.; Cucinotta, F. A.

    2010-01-01

    Chromosome aberrations were measured in human peripheral blood lymphocytes after in vitro exposure to 28Si- ions with energies ranging from 90 to 600 MeV/u, or to 56Fe-ions with energies ranging from 200 to 5,000 MeV/u. The LET of the various Fe beams in this study ranged from 145 to 440 keV/micron and the LET of the Si ions ranged from 48 to 158 keV/ m. Doses delivered were in the 10- to 200-cGy range. Dose-response curves for chromosome exchanges in cells at first division after exposure, measured using fluorescence in situ hybridization (FISH) with whole-chromosome probes, were fitted with linear or linear-quadratic functions. The relative biological effectiveness (RBE) was estimated from the initial slope of the dose-response curve for chromosome damage with respect to -rays. The estimates of RBE(sub max) values for total chromosome exchanges ranged from 4.4+/-0.4 to 31.5+/-2.6 for Fe ions, and 11.8+/-1.0 to 42.2+/-3.3 for Si ions. The highest RBE(sub max) value for Fe ions was obtained with the 600-Mev/u beam, and the highest RBE(sub max) value for Si ions was obtained with the 170 MeV/u beam. For both ions the RBEmax values increased with LET, reaching a maximum at about 180 keV/micron for Fe and about 100 keV/ m for Si, and decreasing with further increase in LET. Additional studies for low doses 28Si-ions down to 0.02 Gy will be discussed.

  8. Derivation of a reference dose for a complex petroleum hydrocarbon mixture

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ryer-Powder, J.E.; LaPirre, A.; Scofield, R.

    1997-12-31

    Petroleum hydrocarbon mixtures pose a challenge in assessing potential health effects associated with environmental exposures through impacted media. Two components of risk assessment that must be addressed when evaluating these mixtures are toxicity and environmental fate. In this paper, we focus on issues regarding toxicity. Specifically, we have developed a methodology to derive a reference dose (RfD) for a complex petroleum hydrocarbon mixture referred to as diluent. Diluent is a solvent used in the production of crude oil and is composed of hydrocarbons in the middle distillate range. Two conservative approaches to developing a reference dose for diluent are presented.more » Both involve separating the diluent into carbon number ranges (e.g., diluent consists of hydrocarbons containing between 5 carbons and greater than 21 carbons, so, the mixture can be divided into mixtures of hydrocarbons having 5 carbons, 6-11 carbons, etcetera) and assigning each range a representative RfD. In the first approach, the representative RfD for each range is that of one specific chemical within the range (e.g., the reference dose for the C{sub 5}-C{sub 8} carbon range is that of n-hexane). In the second approach, the RfD dose for each range is that of a mixture of chemicals representative of each carbon number range (e.g., the RfD for the C{sub 6} to C{sub 11} carbon range is that of mineral spirits). The RfD for each carbon range is then multiplied by the percent of diluent in the corresponding range and the products are added to arrive at a final RfD. The RfD for diluent using the first approach is estimated at 2 mg/kg-day and that using the second approach is estimated at 1 mg/kg-day.« less

  9. Simulated space radiation-induced mutants in the mouse kidney display widespread genomic change

    PubMed Central

    Grygoryev, Dmytro; Lasarev, Michael; Ohlrich, Anna; Rwatambuga, Furaha A.; Johnson, Sorrel; Dan, Cristian; Eckelmann, Bradley; Hryciw, Gwen; Mao, Jian-Hua; Snijders, Antoine M.; Gauny, Stacey; Kronenberg, Amy

    2017-01-01

    Exposure to a small number of high-energy heavy charged particles (HZE ions), as found in the deep space environment, could significantly affect astronaut health following prolonged periods of space travel if these ions induce mutations and related cancers. In this study, we used an in vivo mutagenesis assay to define the mutagenic effects of accelerated 56Fe ions (1 GeV/amu, 151 keV/μm) in the mouse kidney epithelium exposed to doses ranging from 0.25 to 2.0 Gy. These doses represent fluences ranging from 1 to 8 particle traversals per cell nucleus. The Aprt locus, located on chromosome 8, was used to select induced and spontaneous mutants. To fully define the mutagenic effects, we used multiple endpoints including mutant frequencies, mutation spectrum for chromosome 8, translocations involving chromosome 8, and mutations affecting non-selected chromosomes. The results demonstrate mutagenic effects that often affect multiple chromosomes for all Fe ion doses tested. For comparison with the most abundant sparsely ionizing particle found in space, we also examined the mutagenic effects of high-energy protons (1 GeV, 0.24 keV/μm) at 0.5 and 1.0 Gy. Similar doses of protons were not as mutagenic as Fe ions for many assays, though genomic effects were detected in Aprt mutants at these doses. Considered as a whole, the data demonstrate that Fe ions are highly mutagenic at the low doses and fluences of relevance to human spaceflight, and that cells with considerable genomic mutations are readily induced by these exposures and persist in the kidney epithelium. The level of genomic change produced by low fluence exposure to heavy ions is reminiscent of the extensive rearrangements seen in tumor genomes suggesting a potential initiation step in radiation carcinogenesis. PMID:28683078

  10. Simulated space radiation-induced mutants in the mouse kidney display widespread genomic change.

    PubMed

    Turker, Mitchell S; Grygoryev, Dmytro; Lasarev, Michael; Ohlrich, Anna; Rwatambuga, Furaha A; Johnson, Sorrel; Dan, Cristian; Eckelmann, Bradley; Hryciw, Gwen; Mao, Jian-Hua; Snijders, Antoine M; Gauny, Stacey; Kronenberg, Amy

    2017-01-01

    Exposure to a small number of high-energy heavy charged particles (HZE ions), as found in the deep space environment, could significantly affect astronaut health following prolonged periods of space travel if these ions induce mutations and related cancers. In this study, we used an in vivo mutagenesis assay to define the mutagenic effects of accelerated 56Fe ions (1 GeV/amu, 151 keV/μm) in the mouse kidney epithelium exposed to doses ranging from 0.25 to 2.0 Gy. These doses represent fluences ranging from 1 to 8 particle traversals per cell nucleus. The Aprt locus, located on chromosome 8, was used to select induced and spontaneous mutants. To fully define the mutagenic effects, we used multiple endpoints including mutant frequencies, mutation spectrum for chromosome 8, translocations involving chromosome 8, and mutations affecting non-selected chromosomes. The results demonstrate mutagenic effects that often affect multiple chromosomes for all Fe ion doses tested. For comparison with the most abundant sparsely ionizing particle found in space, we also examined the mutagenic effects of high-energy protons (1 GeV, 0.24 keV/μm) at 0.5 and 1.0 Gy. Similar doses of protons were not as mutagenic as Fe ions for many assays, though genomic effects were detected in Aprt mutants at these doses. Considered as a whole, the data demonstrate that Fe ions are highly mutagenic at the low doses and fluences of relevance to human spaceflight, and that cells with considerable genomic mutations are readily induced by these exposures and persist in the kidney epithelium. The level of genomic change produced by low fluence exposure to heavy ions is reminiscent of the extensive rearrangements seen in tumor genomes suggesting a potential initiation step in radiation carcinogenesis.

  11. Detrimental effects of electron beam irradiation on the cowpea bruchid Callosobruchus maculatus.

    PubMed

    Sang, Wen; Speakmon, Mickey; Zhou, Lan; Wang, Yu; Lei, Chaoliang; Pillai, Suresh D; Zhu-Salzman, Keyan

    2016-04-01

    Electron beam (eBeam) irradiation technology is an environmentally friendly, chemical-free alternative for disinfesting insect pests of stored grains. The underlying hypothesis is that specific doses of eBeam will have defined detrimental effects on the different life stages. We evaluated the effects of eBeam exposure in a range of doses (0.03-0.12 kGy) on the development of the cowpea bruchid (Callosobruchus maculatus) at various stages of its life cycle. Differential radiosensitivity was detected during egg development. Early and intermediate stages of eggs never hatched after exposure to a dose of 0.03 kGy, whereas a substantial portion of black-headed (i.e. late) eggs survived irradiation even at 0.12 kGy. However, further development of the hatched larvae was inhibited. Although midgut protein digestion remained intact, irradiated larvae (0.06 kGy or higher) failed to develop into normal living adults; rather, they died as pupae or abnormally eclosed adults, suggesting a detrimental effect of eBeam on metamorphosis. Emerged irradiated pupae had shorter longevity and were unable to produce any eggs at 0.06 kGy or higher. At this dose range, eggs laid by irradiated adults were not viable. eBeam treatment shortened adult longevity in a dose-dependent manner. Reciprocal crosses indicated that females were more sensitive to eBeam exposure than their male counterparts. Dissection of the female reproductive system revealed that eBeam treatment prevented formation of oocytes. eBeam irradiation has very defined effects on cowpea bruchid development and reproduction. A dose of 0.06 kGy could successfully impede cowpea burchid population expansion. This information can be exploited for post-harvest insect control of stored grains. © 2015 Society of Chemical Industry.

  12. Dose-dependent model of caffeine effects on human vigilance during total sleep deprivation.

    PubMed

    Ramakrishnan, Sridhar; Laxminarayan, Srinivas; Wesensten, Nancy J; Kamimori, Gary H; Balkin, Thomas J; Reifman, Jaques

    2014-10-07

    Caffeine is the most widely consumed stimulant to counter sleep-loss effects. While the pharmacokinetics of caffeine in the body is well-understood, its alertness-restoring effects are still not well characterized. In fact, mathematical models capable of predicting the effects of varying doses of caffeine on objective measures of vigilance are not available. In this paper, we describe a phenomenological model of the dose-dependent effects of caffeine on psychomotor vigilance task (PVT) performance of sleep-deprived subjects. We used the two-process model of sleep regulation to quantify performance during sleep loss in the absence of caffeine and a dose-dependent multiplier factor derived from the Hill equation to model the effects of single and repeated caffeine doses. We developed and validated the model fits and predictions on PVT lapse (number of reaction times exceeding 500 ms) data from two separate laboratory studies. At the population-average level, the model captured the effects of a range of caffeine doses (50-300 mg), yielding up to a 90% improvement over the two-process model. Individual-specific caffeine models, on average, predicted the effects up to 23% better than population-average caffeine models. The proposed model serves as a useful tool for predicting the dose-dependent effects of caffeine on the PVT performance of sleep-deprived subjects and, therefore, can be used for determining caffeine doses that optimize the timing and duration of peak performance. Published by Elsevier Ltd.

  13. Errors and Uncertainties in Dose Reconstruction for Radiation Effects Research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.

    Dose reconstruction for studies of the health effects of ionizing radiation have been carried out for many decades. Major studies have included Japanese bomb survivors, atomic veterans, downwinders of the Nevada Test Site and Hanford, underground uranium miners, and populations of nuclear workers. For such studies to be credible, significant effort must be put into applying the best science to reconstructing unbiased absorbed doses to tissues and organs as a function of time. In many cases, more and more sophisticated dose reconstruction methods have been developed as studies progressed. For the example of the Japanese bomb survivors, the dose surrogatemore » “distance from the hypocenter” was replaced by slant range, and then by TD65 doses, DS86 doses, and more recently DS02 doses. Over the years, it has become increasingly clear that an equal level of effort must be expended on the quantitative assessment of uncertainty in such doses, and to reducing and managing uncertainty. In this context, this paper reviews difficulties in terminology, explores the nature of Berkson and classical uncertainties in dose reconstruction through examples, and proposes a path forward for Joint Coordinating Committee for Radiation Effects Research (JCCRER) Project 2.4 that requires a reasonably small level of effort for DOSES-2008.« less

  14. Genetic effects of radiotherapy for childhood cancer: gonadal dose reconstruction.

    PubMed

    Stovall, Marilyn; Donaldson, Sarah S; Weathers, Rita E; Robison, Leslie L; Mertens, Ann C; Winther, Jeanette Falck; Olsen, Jorgen H; Boice, John D

    2004-10-01

    To estimate the doses of radiation to organs of interest during treatment of childhood cancer for use in an epidemiologic study of possible heritable diseases, including birth defects, chromosomal abnormalities, cancer, stillbirth, and neonatal and premature death. The study population was composed of more than 25,000 patients with cancer in Denmark and the United States who were survivors of childhood cancer and subsequently had nearly 6,500 children of their own. Radiation therapy records were sought for the survivors who parented offspring who had adverse pregnancy outcomes (>300 offspring), and for a sample of all survivors in a case-cohort design. The records were imaged and centrally abstracted. Water phantom measurements were made to estimate doses for a wide range of treatments. Mathematical phantoms were used to apply measured results to estimate doses to ovaries, uterus, testes, and pituitary for patients ranging in age from newborn to 25 years. Gonadal shielding, ovarian pinning (oophoropexy), and field blocking were taken into account. Testicular radiation doses ranged from <1 to 700 cGy (median, 7 cGy) and ovarian doses from <1 to >2,500 cGy (median, 13 cGy). Ten percent of the records were incomplete, but sufficient data were available for broad characterizations of gonadal dose. More than 49% of the gonadal doses were >10 cGy and 16% were >100 cGy. Sufficient radiation therapy data exist as far back as 1943 to enable computation of gonadal doses administered for curative therapy for childhood cancer. The range of gonadal doses is broad, and for many cancer survivors, is high and just below the threshold for infertility. Accordingly, the epidemiologic study has >90% power to detect a 1.3-fold risk of an adverse pregnancy outcome associated with radiation exposure to the gonads. This study should provide important information on the genetic consequences of radiation exposure to humans.

  15. The effect of SLCO1B1 polymorphism on repaglinide pharmacokinetics persists over a wide dose range.

    PubMed

    Kalliokoski, Annikka; Neuvonen, Mikko; Neuvonen, Pertti J; Niemi, Mikko

    2008-12-01

    To establish whether the effect of SLCO1B1[encoding organic anion transporting polypeptide 1B1 (OATP1B1)] c.521T-->C (p.Val174Ala) polymorphism on the pharmacokinetics of repaglinide is dose-dependent. Twelve healthy volunteers with the SLCO1B1 c.521TT genotype (controls) and eight with the c.521CC genotype ingested a single 0.25-, 0.5-, 1- or 2-mg dose of repaglinide in a dose-escalation study with a wash-out period of > or =1 week. The mean area under the plasma concentration-time curve from time 0 to infinity (AUC(0-infinity)) of 0.25, 0.5, 1 or 2 mg repaglinide was 82% (95% confidence interval 47, 125), 72% (24, 138), 56% (24, 95) or 108% (59, 171) (P < or = 0.001) larger in participants with the SLCO1B1 c.521CC genotype than in those with the c.521TT genotype, respectively. Repaglinide peak plasma concentration and AUC(0-infinity) increased linearly along with repaglinide dose in both genotype groups (r > 0.88, P < 0.001). There was a tendency towards lower blood glucose concentrations after repaglinide administration in the participants with the c.521CC genotype than in those with the c.521TT genotype. The effect of SLCO1B1 c.521T-->C polymorphism on the pharmacokinetics of repaglinide persists throughout the clinically relevant dose range.

  16. WE-AB-BRB-08: Progress Towards a 2D OSL Dosimetry System Using Al2O3:C Films

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahmed, M F; Yukihara, E; Schnell, E

    Purpose: To develop a 2D dosimetry system based on the optically stimulated luminescence (OSL) of Al{sub 2}O{sub 3}:C films for medical applications. Methods: A 2D laser scanning OSL reader was built for readout of newly developed Al2O3:C films (Landauer Inc.). An image reconstruction algorithm was developed to correct for inherent effects introduced by reader design and detector properties. The system was tested using irradiations with photon and carbon ion beams. A calibration was obtained using a 6 MV photon beam from clinical accelerator and the dose measurement precision was tested using a range of doses and different dose distributions (flatmore » field and wedge field). The dynamic range and performance of the system in the presence of large dose gradients was also tested using 430 MeV/u {sup 12}C single and multiple pencil beams. All irradiations were performed with Gafchromic EBT3 film for comparison. Results: Preliminary results demonstrate a near-linear OSL dose response to photon fields and the ability to measure dose in dose distributions such as flat field and wedge field. Tests using {sup 12}C pencil beam demonstrate ability to measure doses over four orders of magnitude. The dose profiles measured by the OSL film generally agreed well with that measured by the EBT3 film. The OSL image signal-to-noise ratio obtained in the current conditions require further improvement. On the other hand, EBT3 films had large uncertainties in the low dose region due to film-to-film or intra-film variation in the background. Conclusion: A 2D OSL dosimetry system was developed and initial tests have demonstrated a wide dynamic range as well as good agreement between the delivered and measured doses. The low background, wide dynamic range and wide range of linearity in dose response observed for the Al{sub 2}O{sub 3}:C OSL film can be beneficial for dosimetry in radiation therapy applications, especially for small field dosimetry. This work has been funded by Landauer Inc. Dr. Eduardo G. Yukihara also would like to thank the Alexander von Humboldt Foundation for his support at the DKFZ.« less

  17. Radiation processing as a post-harvest quarantine control for raisins, dried figs and dried apricots

    NASA Astrophysics Data System (ADS)

    Cetinkaya, N.; Ozyardımci, B.; Denli, E.; Ic, E.

    2006-03-01

    The commercially packed samples of raisins, dried figs and dried apricots were irradiated using doses in the range of 0.5-1.0 kGy for disinfestation and 0.5-5.0 kGy for sensory analysis with the dose rate ranging from 1.44 to 1.92 kGy/h. Pests on dried fruits were evaluated after 0, 1, 2 and 3 months of storage for irradiated dried figs and 1, 3, 6 and 12 months of storage for raisins and dried apricots. Sensory analysis of dried figs, dried apricots and raisins were carried out after 0, 1, 3, 6 and 12 months of storage. The results indicated that radiation processing at low doses, (˜1.0 kGy) is an effective post-harvest treatment and quarantine control for these products with no adverse effects on sensory (marketing) attributes.

  18. Differences between the nonselective adenosine receptor antagonists caffeine and theophylline in motor and mood effects: studies using medium to high doses in animal models.

    PubMed

    López-Cruz, Laura; Pardo, Marta; Salamone, John D; Correa, Mercè

    2014-08-15

    Caffeine and theophylline are methylxanthines that are broadly consumed, sometimes at high doses, and act as minor psychostimulants. Both are nonselective adenosine antagonists for A1 and A2A receptors, which are colocalized with dopamine D1 and D2 receptors in striatal areas. Adenosine antagonists generally have opposite actions to those of dopamine antagonists. Although the effects of caffeine are widely known, theophylline has been much less well characterized, especially at high doses. Adult male CD1 mice were used to study the effect of a broad range of doses (25.0, 50.0 or 100.0mg/kg) of caffeine and theophylline on measures of spontaneous locomotion and coordination, as well as the pattern of c-Fos immunoreactivity in brain areas rich in adenosine and dopamine receptors. In addition, we evaluated possible anxiety and stress effects of these doses. Caffeine, at these doses, impaired or suppressed locomotion in several paradigms. However, theophylline was less potent than caffeine at suppressing motor parameters, and even stimulated locomotion. Both drugs induced corticosterone release, however caffeine was more efficacious at intermediate doses. While caffeine showed an anxiogenic profile at all doses, theophylline only did so at the highest dose used (50mg/kg). Only theophylline increased c-Fos immunoreactivity in cortical areas. Theophylline has fewer disruptive effects than caffeine on motor parameters and produces less stress and anxiety effects. These results are relevant for understanding the potential side effects of methylxanthines when consumed at high doses. Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Intraarticular Sacroiliac Joint Injection Under Computed Tomography Fluoroscopic Guidance: A Technical Note to Reduce Procedural Time and Radiation Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Paik, Nam Chull, E-mail: pncspine@gmail.com

    2016-07-15

    PurposeA technique for computed tomography fluoroscopy (CTF)-guided intraarticular (IA) sacroiliac joint (SIJ) injection was devised to limit procedural time and radiation dose.MethodsOur Institutional Review Board approved this retrospective analysis and waived the requirement for informed consent. Overall, 36 consecutive diagnostic or therapeutic IA SIJ injections (unilateral, 20; bilateral, 16) performed in 34 patients (female, 18; male, 16) with a mean age of 45.5 years (range 20–76 years) under CTF guidance were analyzed, assessing technical success (i.e., IA contrast spread), procedural time, and radiation dose.ResultsAll injections were successful from a technical perspective and were free of serious complications. Respective median proceduralmore » times and effective doses of SIJ injection were as follows: unilateral, 5.28 min (range 3.58–8.00 min) and 0.11 millisievert (mSv; range 0.07–0.24 mSv); and bilateral, 6.72 min (range 4.17–21.17 min) and 0.11 mSv (range 0.09–0.51 mSv).ConclusionsGiven the high rate of technical success achieved in limited time duration and with little radiation exposure, CTF-guided IA SIJ injection is a practical and low-risk procedure.« less

  20. Evaluation of the dosimetric properties of a synthetic single crystal diamond detector in high energy clinical proton beams.

    PubMed

    Mandapaka, A K; Ghebremedhin, A; Patyal, B; Marinelli, Marco; Prestopino, G; Verona, C; Verona-Rinati, G

    2013-12-01

    To investigate the dosimetric properties of a synthetic single crystal diamond Schottky diode for accurate relative dose measurements in large and small field high-energy clinical proton beams. The dosimetric properties of a synthetic single crystal diamond detector were assessed by comparison with a reference Markus parallel plate ionization chamber, an Exradin A16 microionization chamber, and Exradin T1a ion chamber. The diamond detector was operated at zero bias voltage at all times. Comparative dose distribution measurements were performed by means of Fractional depth dose curves and lateral beam profiles in clinical proton beams of energies 155 and 250 MeV for a 14 cm square cerrobend aperture and 126 MeV for 3, 2, and 1 cm diameter circular brass collimators. ICRU Report No. 78 recommended beam parameters were used to compare fractional depth dose curves and beam profiles obtained using the diamond detector and the reference ionization chamber. Warm-up∕stability of the detector response and linearity with dose were evaluated in a 250 MeV proton beam and dose rate dependence was evaluated in a 126 MeV proton beam. Stem effect and the azimuthal angle dependence of the diode response were also evaluated. A maximum deviation in diamond detector signal from the average reading of less than 0.5% was found during the warm-up irradiation procedure. The detector response showed a good linear behavior as a function of dose with observed deviations below 0.5% over a dose range from 50 to 500 cGy. The detector response was dose rate independent, with deviations below 0.5% in the investigated dose rates ranging from 85 to 300 cGy∕min. Stem effect and azimuthal angle dependence of the diode signal were within 0.5%. Fractional depth dose curves and lateral beam profiles obtained with the diamond detector were in good agreement with those measured using reference dosimeters. The observed dosimetric properties of the synthetic single crystal diamond detector indicate that its behavior is proton energy independent and dose rate independent in the investigated energy and dose rate range and it is suitable for accurate relative dosimetric measurements in large as well as in small field high energy clinical proton beams.

  1. Ion recombination and polarity correction factors for a plane-parallel ionization chamber in a proton scanning beam.

    PubMed

    Liszka, Małgorzata; Stolarczyk, Liliana; Kłodowska, Magdalena; Kozera, Anna; Krzempek, Dawid; Mojżeszek, Natalia; Pędracka, Anna; Waligórski, Michael Patrick Russell; Olko, Paweł

    2018-01-01

    To evaluate the effect on charge collection in the ionization chamber (IC) in proton pencil beam scanning (PBS), where the local dose rate may exceed the dose rates encountered in conventional MV therapy by up to three orders of magnitude. We measured values of the ion recombination (k s ) and polarity (k pol ) correction factors in water, for a plane-parallel Markus TM23343 IC, using the cyclotron-based Proteus-235 therapy system with an active proton PBS of energies 30-230 MeV. Values of k s were determined from extrapolation of the saturation curve and the Two-Voltage Method (TVM), for planar fields. We compared our experimental results with those obtained from theoretical calculations. The PBS dose rates were estimated by combining direct IC measurements with results of simulations performed using the FLUKA MC code. Values of k s were also determined by the TVM for uniformly irradiated volumes over different ranges and modulation depths of the proton PBS, with or without range shifter. By measuring charge collection efficiency versus applied IC voltage, we confirmed that, with respect to ion recombination, our proton PBS represents a continuous beam. For a given chamber parameter, e.g., nominal voltage, the value of k s depends on the energy and the dose rate of the proton PBS, reaching c. 0.5% for the TVM, at the dose rate of 13.4 Gy/s. For uniformly irradiated regular volumes, the k s value was significantly smaller, within 0.2% or 0.3% for irradiations with or without range shifter, respectively. Within measurement uncertainty, the average value of k pol , for the Markus TM23343 IC, was close to unity over the whole investigated range of clinical proton beam energies. While no polarity effect was observed for the Markus TM23343 IC in our pencil scanning proton beam system, the effect of volume recombination cannot be ignored. © 2017 American Association of Physicists in Medicine.

  2. The Biological Effectiveness of Different Radiation Qualities for the Induction of Chromosome Damage in Human Lymphocytes

    NASA Technical Reports Server (NTRS)

    Hada, M.; George, Kerry; Cucinotta, F. A.

    2011-01-01

    Chromosome aberrations were measured in human peripheral blood lymphocytes after in vitro exposure to Si-28-ions with energies ranging from 90 to 600 MeV/u, Ti-48-ions with energies ranging from 240 to 1000 MeV/u, or to Fe-56-ions with energies ranging from 200 to 5,000 MeV/u. The LET of the various Si beams in this study ranged from 48 to 158 keV/ m, the LET of the Ti ions ranged from 107 to 240 keV/micron, and the LET of the Fe-ions ranged from 145 to 440 keV/ m. Doses delivered were in the 10- to 200-cGy range. Dose-response curves for chromosome exchanges in cells at first division after exposure, measured using fluorescence in situ hybridization (FISH) with whole-chromosome probes, were fitted with linear or linear-quadratic functions. The relative biological effectiveness (RBE) was estimated from the initial slope of the dose-response curve for chromosome damage with respect to gamma-rays. The estimates of RBEmax values for total chromosome exchanges ranged from 4.4+/-0.4 to 31.5+/-2.6 for Fe ions, 21.4+/-1.7 to 28.3+/-2.4 for Ti ions, and 11.8+/-1.0 to 42.2+/-3.3 for Si ions. The highest RBEmax value for Fe ions was obtained with the 600 MeV/u beam, the highest RBEmax value for Ti ions was obtained 1000 MeV/u beam, and the highest RBEmax value for Si ions was obtained with the 170 MeV/u beam. For Si and Fe ions the RBEmax values increased with LET, reaching a maximum at about 180 keV/micron for Fe and about 100 keV/micron for Si, and decreasing with further increase in LET. Additional studies for low doses Si-28-ions down to 0.02 Gy will be discussed.

  3. Comparison of Effects Produced by Nicotine and the α4β2-Selective Agonist 5-I-A-85380 On Intracranial Self-Stimulation in Rats

    PubMed Central

    Freitas, Kelen; Carroll, F. Ivy; Negus, S. Stevens

    2015-01-01

    Intracranial self-stimulation (ICSS) is one type of preclinical procedure for research on pharmacological mechanisms that mediate abuse potential of drugs acting at various targets including nicotinic acetylcholine receptors (nAChRs). This study compared effects of the non-selective nAChR agonist nicotine (0.032-1.0 mg/kg) and the α4β2-selective nAChR agonist 5-I-A-85380 (0.01-1.0 mg/kg) on ICSS in male Sprague-Dawley rats. Rats were implanted with electrodes targeting the medial forebrain bundle at the level of the lateral hypothalamus and trained to respond under a fixed-ratio 1 schedule for a range of brain stimulation frequencies (158-56 Hz). A broad range of 5-I-A-85380 doses produced an abuse-related increase (or “facilitation”) of low ICSS rates maintained by low brain-stimulation frequencies, and this effect was blocked by both the nonselective nAChR antagonist mecamylamine and the selective α4β2 antagonist dihyrdo-ß-erythroidine (DHßE). Conversely, nicotine produced weaker ICSS facilitation across a narrower range of doses, and higher nicotine doses decreased high rates of ICSS maintained by high brain- stimulation frequencies. The rate-decreasing effects of a high nicotine dose were blocked by mecamylamine but not DHßE. Chronic nicotine treatment produced selective tolerance to rate-decreasing effects of nicotine but did not alter ICSS rate-increasing effects of nicotine. These results suggest that α4β2 receptors are sufficient to mediate abuse-related rate-increasing effects of nAChR agonists in this ICSS procedure. Conversely, nicotine effects at non-α4β2 nAChRs appear to oppose and limit abuse-related effects mediated by α4β2 receptors, although tolerance can develop to these non-α4β2 effects. Selective α4β2 agonists may have higher abuse potential than nicotine. PMID:26461167

  4. Evaluation of the Pharmacokinetics of Single- and Multiple-dose Buprenorphine Buccal Film in Healthy Volunteers.

    PubMed

    Bai, Stephen A; Xiang, Qinfang; Finn, Andrew

    2016-02-01

    Buprenorphine, a partial μ-receptor agonist, is approved for the management of moderate to severe pain, but it has low oral bioavailability. Two open-label studies were performed to determine the pharmacokinetic profile of buprenorphine from buccal film formulations of buprenorphine. Both studies enrolled healthy volunteers, aged 18 to 55 years, who received concurrent oral naltrexone to reduce adverse events (AEs); subjects with a history or evidence of substance abuse or current use of any product affecting cytochrome P450 3A4 activity were excluded. The first study (n = 25) was a 5-period crossover trial with 4 single doses (75 and 300 and 300 and 1200 μg) of 2 formulations (F14 and F24) of buccal buprenorphine (BBUP) and a 300-μg intravenous dose of buprenorphine with a 7-day washout between periods. In the second study, each subject (n = 10) received 6 doses of 4 BBUP strengths (60, 120, 180, and 240 μg BID) in a dose-escalation design. Plasma concentrations of buprenorphine and norbuprenorphine were assayed, and pharmacokinetics were summarized with descriptive statistics and analyzed by using a linear mixed effects model (single-dose study). AEs were recorded. In the single-dose study, the 2 formulations exhibited comparable bioavailability of 46% to 51% that was independent of dose, with a single buprenorphine peak concentration from each BBUP dose occurring at 2.5 to 3 hours. The mean buprenorphine Cmax across the doses ranged from 0.17 ng/mL for the 75-µg dose to 1.43 ng/mL for the 1200-µg dose. AUC0-∞, AUC0-last, and Cmax were proportional to the dose of BBUP administered. Cmax of norbuprenorphine after BBUP administration was approximately one tenth that of buprenorphine Cmax. In the multiple-dose study, steady state was reached within 3 days of BID dosing. There was a linear increase in exposure across the dose range from 60 to 240 μg BID. Treatment-emergent AEs in both studies were consistent with those reported with opiate administration to healthy volunteers. The absolute bioavailability of BBUP was 46% to 51% across a 16-fold dose range, with dose-proportional increases in systemic exposure. Apparent steady-state conditions occurred within 3 days of dosing. These pharmacokinetic results suggest that therapeutic buprenorphine plasma concentrations can be obtained with BBUP across a wide dose range in a shorter time than other (eg, transdermal) dosage forms. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, N

    Purpose: Ocular proton therapy has the following advantages: i) sparing optic nerve, ii) the minimal dose is delivered to surrounding normal tissues. Since the proton therapy center was opened in 2007, 30 patients with ocular tumor have been treated at National Cancer Center using single scattering technique. To develop a solid eye phantom which can verify the output and the beam range with EBT3 film for independent patient QA in ocular proton therapy. Methods: The proton therapy is very effective to treat ocular tumor, because of the Bragg peak feature. In general, the beam shape of eye treatment is aboutmore » 3 cm in diameter and the beam range is under 5 cm. However, proton therapy has uncertainty of beam range problem due to various stopping power of normal tissue, bone, air and so on, so that we should verify the beam range before treatment. For this purpose, a new PMMA phantom with wedge has been developed to use the film dosimetry and the ionization chamber. It is able to place a film on the slope of the phantom, which the spread out Bragg Peak by the water equivalent thickness value of PMMA can be made on the film. We considered to relation with quenching effect of proton energy and range for simple second check. In addition, the ionization chamber (Pin-point chamber, PTW 31014) can be inserted into a hole in the phantom to measure the absolute dose. Results: The output difference and beam range difference were less than 2% and 1.0 mm, respectively, between the measurement and the plan. Conclusion: An eye phantom was developed and its performance was evaluated successfully and it was useful to verify the output. Also with EBT3 film with the quenching effect for measurement depth-dose profile, range to patient QA.« less

  6. Incorporating partial shining effects in proton pencil-beam dose calculation

    NASA Astrophysics Data System (ADS)

    Li, Yupeng; Zhang, Xiaodong; Fwu Lii, Ming; Sahoo, Narayan; Zhu, Ron X.; Gillin, Michael; Mohan, Radhe

    2008-02-01

    A range modulator wheel (RMW) is an essential component in passively scattered proton therapy. We have observed that a proton beam spot may shine on multiple steps of the RMW. Proton dose calculation algorithms normally do not consider the partial shining effect, and thus overestimate the dose at the proximal shoulder of spread-out Bragg peak (SOBP) compared with the measurement. If the SOBP is adjusted to better fit the plateau region, the entrance dose is likely to be underestimated. In this work, we developed an algorithm that can be used to model this effect and to allow for dose calculations that better fit the measured SOBP. First, a set of apparent modulator weights was calculated without considering partial shining. Next, protons spilled from the accelerator reaching the modulator wheel were simplified as a circular spot of uniform intensity. A weight-splitting process was then performed to generate a set of effective modulator weights with the partial shining effect incorporated. The SOBPs of eight options, which are used to label different combinations of proton-beam energy and scattering devices, were calculated with the generated effective weights. Our algorithm fitted the measured SOBP at the proximal and entrance regions much better than the ones without considering partial shining effect for all SOBPs of the eight options. In a prostate patient, we found that dose calculation without considering partial shining effect underestimated the femoral head and skin dose.

  7. [Oral loading dose of phenytoin in the treatment of serial seizures, prevention of seizure recurrence and rapid drug substitution].

    PubMed

    Sokić, D; Janković, S M

    1994-01-01

    Over a period of nine months twenty-five epileptic patients were treated with the oral loading dose of phenytoin. The dose ranged from 12 to 23 mg/kg body weight during 1 to 12 hours. In 20 patients with serial seizures or intolerance to other antiepileptic drugs this treatment was effective. Seizures also stopped in 2 of 4 patients with serial partial motor seizures. These 2 patients required both higher loading dose and faster rate of administration than the other patients. A patient with epilepsia partialis continua failed to respond to the treatment. Patients that received phenytoin through the naso-gastric tube, in respect to oral administration, required higher doses to obtain therapeutic plasma levels of phenytoin. One patient had mild nausea, 3 mild dizziness, and 1 tinitus on the first day of the treatment. There was no correlation between a given dose and the achieved phenytoin plasma levels. In our opinion the therapy with oral loading dose of phenytoin is highly effective in the treatment of serial generalized seizures and rapid antiepileptic drug substitution, and partially effective in the prevention of partial motor seizures. It produces only mild and transient side-effects.

  8. Metabolic disruption in male mice due to fetal exposure to low but not high doses of bisphenol A (BPA): Evidence for effects on body weight, food intake, adipocytes, leptin, adiponectin, insulin and glucose regulation

    PubMed Central

    Angle, Brittany M.; Do, Rylee Phuong; Ponzi, Davide; Stahlhut, Richard W.; Drury, Bertram E.; Nagel, Susan C.; Welshons, Wade V.; Besch-Williford, Cynthia L; Palanza, Paola; Parmigiani, Stefano; vom Saal, Frederick S.; Taylor, Julia A.

    2013-01-01

    Exposure to bisphenol A (BPA) is implicated in many aspects of metabolic disease in humans and experimental animals. We fed pregnant CD-1 mice BPA at doses ranging from 5 to 50,000 μg/kg/day, spanning 10-fold below the reference dose to 10-fold above the currently predicted no adverse effect level (NOAEL). At BPA doses below the NOAEL that resulted in average unconjugated BPA between 2 and 200pg/ml in fetal serum (AUC0–24h),we observed significant effects in adult male offspring: an age-related change in food intake, an increase in body weight and liver weight, abdominal adipocyte mass, number and volume, and in serum leptin and insulin, but a decrease in serum adiponectin and in glucose tolerance. For most of these outcomes non-monotonic dose–response relationships were observed; the highest BPA dose did not produce a significant effect for any outcome. A 0.1-μg/kg/day dose of DES resulted in some but not all low-dose BPA outcomes. PMID:23892310

  9. Dose-distance metric that predicts late rectal bleeding in patients receiving radical prostate external-beam radiotherapy

    NASA Astrophysics Data System (ADS)

    Lee, Richard; Chan, Elisa K.; Kosztyla, Robert; Liu, Mitchell; Moiseenko, Vitali

    2012-12-01

    The relationship between rectal dose distribution and the incidence of late rectal complications following external-beam radiotherapy has been previously studied using dose-volume histograms or dose-surface histograms. However, they do not account for the spatial dose distribution. This study proposes a metric based on both surface dose and distance that can predict the incidence of rectal bleeding in prostate cancer patients treated with radical radiotherapy. One hundred and forty-four patients treated with radical radiotherapy for prostate cancer were prospectively followed to record the incidence of grade ≥2 rectal bleeding. Radiotherapy plans were used to evaluate a dose-distance metric that accounts for the dose and its spatial distribution on the rectal surface, characterized by a logistic weighting function with slope a and inflection point d0. This was compared to the effective dose obtained from dose-surface histograms, characterized by the parameter n which describes sensitivity to hot spots. The log-rank test was used to determine statistically significant (p < 0.05) cut-off values for the dose-distance metric and effective dose that predict for the occurrence of rectal bleeding. For the dose-distance metric, only d0 = 25 and 30 mm combined with a > 5 led to statistical significant cut-offs. For the effective dose metric, only values of n in the range 0.07-0.35 led to statistically significant cut-offs. The proposed dose-distance metric is a predictor of rectal bleeding in prostate cancer patients treated with radiotherapy. Both the dose-distance metric and the effective dose metric indicate that the incidence of grade ≥2 rectal bleeding is sensitive to localized damage to the rectal surface.

  10. Systematic review of the effect of radiation dose on tumor control and morbidity in the treatment of prostate cancer by 3D-CRT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tol-Geerdink, Julia J. van; Stalmeier, Peep F.M.; Department of Medical Technology Assessment, Radboud University Nijmegen Medical Center, Nijmegen

    Purpose: A higher radiation dose is believed to result in a larger probability of tumor control and a higher risk of side effects. To make an evidence-based choice of dose, the relation between dose and outcome needs to be known. This study focuses on the dose-response relation for prostate cancer. Methods and Materials: A systematic review was carried out on the literature from 1990 to 2003. From the selected studies, the radiation dose, the associated 5-year survival, 5-year bNED (biochemical no evidence of disease), acute and late gastrointestinal (GI) and genitourinary (GU) morbidity Grade 2 or more, and sexual dysfunctionmore » were extracted. With logistic regression models, the relation between dose and outcome was described. Results: Thirty-eight studies met our criteria, describing 87 subgroups and involving up to 3000 patients per outcome measure. Between the (equivalent) dose of 70 and 80 Gy, various models estimated an increase in 5-year survival (ranging from 10% to 11%), 5-year bNED for low-risk patients (5-7%), late GI complications (12-16%), late GU complications (8-10%), and erectile dysfunction (19-24%). Only for the overall 5-year bNED, results were inconclusive (range, 0-18%). Conclusions: The data suggest a relationship between dose and outcome measures, including survival. However, the strength of these conclusions is limited by the sometimes small number of studies, the incompleteness of the data, and above all, the correlational nature of the data. Unambiguous proof for the dose-response relationships can, therefore, only be obtained by conducting randomized trials.« less

  11. Peak skin and eye lens radiation dose from brain perfusion CT based on Monte Carlo simulation.

    PubMed

    Zhang, Di; Cagnon, Chris H; Villablanca, J Pablo; McCollough, Cynthia H; Cody, Dianna D; Stevens, Donna M; Zankl, Maria; Demarco, John J; Turner, Adam C; Khatonabadi, Maryam; McNitt-Gray, Michael F

    2012-02-01

    The purpose of our study was to accurately estimate the radiation dose to skin and the eye lens from clinical CT brain perfusion studies, investigate how well scanner output (expressed as volume CT dose index [CTDI(vol)]) matches these estimated doses, and investigate the efficacy of eye lens dose reduction techniques. Peak skin dose and eye lens dose were estimated using Monte Carlo simulation methods on a voxelized patient model and 64-MDCT scanners from four major manufacturers. A range of clinical protocols was evaluated. CTDI(vol) for each scanner was obtained from the scanner console. Dose reduction to the eye lens was evaluated for various gantry tilt angles as well as scan locations. Peak skin dose and eye lens dose ranged from 81 mGy to 348 mGy, depending on the scanner and protocol used. Peak skin dose and eye lens dose were observed to be 66-79% and 59-63%, respectively, of the CTDI(vol) values reported by the scanners. The eye lens dose was significantly reduced when the eye lenses were not directly irradiated. CTDI(vol) should not be interpreted as patient dose; this study has shown it to overestimate dose to the skin or eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy.

  12. Naloxone reversal of buprenorphine-induced respiratory depression.

    PubMed

    van Dorp, Eveline; Yassen, Ashraf; Sarton, Elise; Romberg, Raymonda; Olofsen, Erik; Teppema, Luc; Danhof, Meindert; Dahan, Albert

    2006-07-01

    The objective of this investigation was to examine the ability of the opioid antagonist naloxone to reverse respiratory depression produced by the mu-opioid analgesic, buprenorphine, in healthy volunteers. The studies were designed in light of the claims that buprenorphine is relatively resistant to the effects of naloxone. In a first attempt, the effect of an intravenous bolus dose of 0.8 mg naloxone was assessed on 0.2 mg buprenorphine-induced respiratory depression. Next, the effect of increasing naloxone doses (0.5-7 mg, given over 30 min) on 0.2 mg buprenorphine-induced respiratory depression was tested. Subsequently, continuous naloxone infusions were applied to reverse respiratory depression from 0.2 and 0.4 mg buprenorphine. All doses are per 70 kg. Respiration was measured against a background of constant increased end-tidal carbon dioxide concentration. An intravenous naloxone dose of 0.8 mg had no effect on respiratory depression from buprenorphine. Increasing doses of naloxone given over 30 min produced full reversal of buprenorphine effect in the dose range of 2-4 mg naloxone. Further increasing the naloxone dose (doses of 5 mg or greater) caused a decline in reversal activity. Naloxone bolus doses of 2-3 mg, followed by a continuous infusion of 4 mg/h, caused full reversal within 40-60 min of both 0.2 and 0.4 mg buprenorphine-induced respiratory depression. Reversal of buprenorphine effect is possible but depends on the buprenorphine dose and the correct naloxone dose window. Because respiratory depression from buprenorphine may outlast the effects of naloxone boluses or short infusions, a continuous infusion of naloxone may be required to maintain reversal of respiratory depression.

  13. Integrated pharmacokinetics and pharmacodynamics of Ro 48-8684, a new benzodiazepine, in comparison with midazolam during first administration to healthy male subjects.

    PubMed

    van Gerven, J M; Roncari, G; Schoemaker, R C; Massarella, J; Keesmaat, P; Kooyman, H; Heizmann, P; Zell, M; Cohen, A F; Dingemanse, J

    1997-11-01

    This study aimed to investigate the pharmacodynamics and pharmacokinetics of ascending doses of Ro 48-8684, compared with midazolam, in healthy subjects during first administration to man. The study was double-blind and five-way crossover (three ascending doses, placebo, fixed midazolam dose), performed in two groups of five males. Ro 48-8684 was infused in doses of 0.1-0.3-1 mg in the first group, and 1-3-10 mg in the second, with different infusion rates (expressed as mg min(-1)) among doses. Midazolam was infused at 0.1 mg(-1) kg. Infusions were stopped after 20 min or if sedation became too strong for proper performance of saccadic eye movements. Pharmacokinetics and pharmacodynamics and their relationships were evaluated as described in the companion article. Ro 48-8684 caused dose-dependent sedation. No serious adverse events occurred. The volume of distribution and clearance of Ro 48-8684 were larger than of midazolam (337+/-114 vs 50+/-121 and 2.4+/-0.5 vs 0.47+/-0.11 l min(-1), resp). The recovery of saccadic eye movements from equal levels of sedation was on average almost half an hour faster for Ro 48-8684 than for midazolam, with considerable interindividual differences (range 2, 55 min). The doses of Ro 48-8684 leading to the same clinical endpoint as midazolam were comparable, but the corresponding predicted effect compartment concentrations of Ro 48-8684 were on average 2.6 times lower (range 1.5, 4.9 times). The slope of the linear concentration-effect-relationship for saccadic peak velocity was on average 2.2 times steeper for 10 mg Ro 48-8684 than for midazolam (range 1.3, 3.3). The slope decreased on average 4.4-fold (range 1.6, 7.3 times), with doses of Ro 48-8684 increasing from 1 to 10 mg. The metabolite Ro 61-2466 had a longer half-life than the parent compound Ro 48-8684. The influence of this metabolite during prolonged administration should be further investigated. These results show that Ro 48-8684 has a considerably shorter duration of action than midazolam. There may be a reduction of sensitivity to Ro 48-8684 with repeated administration of rising doses due to as yet undetermined factors.

  14. Submillimeter ionoacoustic range determination for protons in water at a clinical synchrocyclotron.

    PubMed

    Lehrack, Sebastian; Assmann, Walter; Bertrand, Damien; Henrotin, Sebastien; Herault, Joel; Heymans, Vincent; Stappen, Francois Vander; Thirolf, Peter G; Vidal, Marie; Van de Walle, Jarno; Parodi, Katia

    2017-08-18

    Proton ranges in water between 145 MeV to 227 MeV initial energy have been measured at a clinical superconducting synchrocyclotron using the acoustic signal induced by the ion dose deposition (ionoacoustic effect). Detection of ultrasound waves was performed by a very sensitive hydrophone and signals were stored in a digital oscilloscope triggered by secondary prompt gammas. The ionoacoustic range measurements were compared to existing range data from a calibrated range detector setup on-site and agreement of better than 1 mm was found at a Bragg peak dose of about 10 Gy for 220 MeV initial proton energy, compatible with the experimental errors. Ionoacoustics has thus the potential to measure the Bragg peak position with submillimeter accuracy during proton therapy, possibly correlated with ultrasound tissue imaging.

  15. Nuclear disaster after the earthquake and tsunami of March 11.

    PubMed

    Shigematsu, Naoyuki; Fukada, Junichi; Ohashi, Toshio; Kawaguchi, Osamu; Kawata, Tetsuya

    2012-01-01

    We would like to explain the effects of radiation on human health and discuss the actual effects of the contamination with radioactive material present in Tokyo. Currently, external exposure doses are within the allowable range in Tokyo and will have no adverse health effects on adults or children. As for internal exposure doses, there will likely be no problems as regards our ordinary dietary intakes. However, hot spots of Cs-134, Sr-90 and others should be monitored further.

  16. Cost-effectiveness decision analysis of intramuscular ceftriaxone versus oral cefixime in adolescents with gonococcal cervicitis.

    PubMed

    Friedland, L R; Kulick, R M; Biro, F M; Patterson, A

    1996-03-01

    We compared the cost-effectiveness of two single-dose treatment strategies for adolescents with uncomplicated Neisseria gonorrhoeae cervicitis. We used a cost-effectiveness decision- analysis model to compare the two methods: the standard, ceftriaxone 125 mg given by IM injection; and an alternative, cefixime 400 mg given orally. The effect of the costs associated with the risk of accidental needlestick during IM administration was also evaluated. Key baseline assumptions (with ranges, when tested) were from the literature or costs to our hospital. These included ceftriaxone, $8.60 per dose; cefixime, $4.67 per dose; ceftriaxone efficacy, 98% (range, 94.9% to 100%); cefixime efficacy, 97% (94.1% to 100%); and a 15% probability of pelvic inflammatory disease (PID) related to failed treatment. We included costs for PID necessitating hospitalization, disseminated gonococcal infection, infertility, and ectopic pregnancy. Assumptions related to accidental needlestick included the rate of needlesticks with the disposable syringe, 6.9 per 100,000 injections (range, 0 to 69); cost of accidental needlestick to hospital; risk of HIV seroconversion after needlestick exposure to HIV-infected blood, .36% (range, 0% to .86%); rate of HIV infection in 15- to 19-year-olds attending sexually transmitted diseases clinics, .4% (range, 0 to 5); and lifetime treatment costs for a person with HIV. At baseline values the model favored ceftriaxone ($45 per patient) or cefixime ($59 per patient). However, over the range of efficacy of both drugs, two-way sensitivity analysis revealed no consistent cost advantage for either drug. The model was also insensitive to the economic effects associated with the risk of accidental needlestick during IM injection. over the range of efficacy by the 95% confidence intervals of both drugs, our analysis demonstrated no clear cost advantage for either. The economic effects of accidental needlestick do not change this conclusion. Compared with the IM alternative, oral cefixime is painless to the patient and simpler for the practitioner to administer. Oral cefixime also eliminates the psychologic effects associated with needlesticks in health care workers. For these reasons, we favor the use of oral cefixime for uncomplicated gonococcal cervicitis in adolescents.

  17. LONG-RANGE RESULTS OF THE RADIOACTIVE PHOSPHORUS THERAPY OF POLYCYTHEMIA VERA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fazekas, S.; Nagy, G.; Petranyi, G.

    1963-02-01

    The results of P/sup 32/ treatment of 22 patients with polycythemia vera are presented. Some patients received a single dose of P/sup 32/, others repeated doses. In general the therapeutic effect was satisfactory. The average length of remission after the first treatment was 10.8 months. (P.C.H.)

  18. [15 years after the accident at the Chernobyl Nuclear Power Plant].

    PubMed

    Buldakov, L A; Gus'kova, A K

    2002-01-01

    Health effects as a result of the accident at the Chernobyl nuclear power plant occurred in 1986 are considered in the paper. Wrong prognosis of the health effects with respect to mortality and morbidity among the population exposed to low radiation doses is shown. Proven increase in thyroid cancer cases among people who were children aged from 0 to 18 at the time of the accident is shown. Linear relationship between thyroid cancer cases and dose to thyroid ranged from 0.2 to 4.0 Gy is considered. An additional absolute risk of thyroid cancer in children varies in the range 1.9-2.6 cases per 10(4) person-year Gy. During the fifteen years following the accident no cases of acute and chronic radiation sickness have been revealed because the population living in contaminated areas received low radiation doses. Also, exposures to low radiation doses did not result in excess of malignant tumors among population. In some cases the outcomes of acute radiation sickness were as follows: radiation damages to the skin, cancer cataracts, development of oncopathology.

  19. Vitamin D and muscle function.

    PubMed

    Dawson-Hughes, Bess

    2017-10-01

    Muscle weakness is a hallmark of severe vitamin D deficiency, but the effect of milder vitamin D deficiency or insufficiency on muscle mass and performance and risk of falling is uncertain. In this presentation, I review the evidence that vitamin D influences muscle mass and performance, balance, and risk of falling in older adults. Special consideration is given to the impact of both the starting 25-hydroxyvitamin D [25(OH)D] level and the dose administered on the clinical response to supplemental vitamin D in older men and women. Based on available evidence, older adults with serum 25(OH)D levels <40nmol/L appear most likely to improve their muscle performance with supplementation. The vitamin D dose range of 800-1000 IU per day has been effective in many studies; lower doses have generally been ineffective and several doses above this range have increased the risk of falls. In conclusion, older adults with serum 25(OH)D levels <40nmol/L are likely to have fewer falls if supplemented with 800-1000 IU per day of vitamin D. Copyright © 2017 Elsevier Ltd. All rights reserved.

  20. Geometrical correction of the e-beam proximity effect for raster scan systems

    NASA Astrophysics Data System (ADS)

    Belic, Nikola; Eisenmann, Hans; Hartmann, Hans; Waas, Thomas

    1999-06-01

    Increasing demands on pattern fidelity and CD accuracy in e- beam lithography require a correction of the e-beam proximity effect. The new needs are mainly coming from OPC at mask level and x-ray lithography. The e-beam proximity limits the achievable resolution and affects neighboring structures causing under- or over-exposion depending on the local pattern densities and process settings. Methods to compensate for this unequilibrated does distribution usually use a dose modulation or multiple passes. In general raster scan systems are not able to apply variable doses in order to compensate for the proximity effect. For system of this kind a geometrical modulation of the original pattern offers a solution for compensation of line edge deviations due to the proximity effect. In this paper a new method for the fast correction of the e-beam proximity effect via geometrical pattern optimization is described. The method consists of two steps. In a first step the pattern dependent dose distribution caused by back scattering is calculated by convolution of the pattern with the long range part of the proximity function. The restriction to the long range part result in a quadratic sped gain in computing time for the transformation. The influence of the short range part coming from forward scattering is not pattern dependent and can therefore be determined separately in a second step. The second calculation yields the dose curve at the border of a written structure. The finite gradient of this curve leads to an edge displacement depending on the amount of underground dosage at the observed position which was previously determined in the pattern dependent step. This unintended edge displacement is corrected by splitting the line into segments and shifting them by multiples of the writers address grid to the opposite direction.

  1. SU-F-T-192: Study of Robustness Analysis Method of Multiple Field Optimized IMPT Plans for Head & Neck Patients

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Y; Wang, X; Li, H

    Purpose: Proton therapy is more sensitive to uncertainties than photon treatments due to protons’ finite range depending on the tissue density. Worst case scenario (WCS) method originally proposed by Lomax has been adopted in our institute for robustness analysis of IMPT plans. This work demonstrates that WCS method is sufficient enough to take into account of the uncertainties which could be encountered during daily clinical treatment. Methods: A fast and approximate dose calculation method is developed to calculate the dose for the IMPT plan under different setup and range uncertainties. Effects of two factors, inversed square factor and range uncertainty,more » are explored. WCS robustness analysis method was evaluated using this fast dose calculation method. The worst-case dose distribution was generated by shifting isocenter by 3 mm along x,y and z directions and modifying stopping power ratios by ±3.5%. 1000 randomly perturbed cases in proton range and x, yz directions were created and the corresponding dose distributions were calculated using this approximated method. DVH and dosimetric indexes of all 1000 perturbed cases were calculated and compared with the result using worst case scenario method. Results: The distributions of dosimetric indexes of 1000 perturbed cases were generated and compared with the results using worst case scenario. For D95 of CTVs, at least 97% of 1000 perturbed cases show higher values than the one of worst case scenario. For D5 of CTVs, at least 98% of perturbed cases have lower values than worst case scenario. Conclusion: By extensively calculating the dose distributions under random uncertainties, WCS method was verified to be reliable in evaluating the robustness level of MFO IMPT plans of H&N patients. The extensively sampling approach using fast approximated method could be used in evaluating the effects of different factors on the robustness level of IMPT plans in the future.« less

  2. The effect of radiation dose on the onset and progression of radiation-induced brain necrosis in the rat model.

    PubMed

    Hartl, Brad A; Ma, Htet S W; Hansen, Katherine S; Perks, Julian; Kent, Michael S; Fragoso, Ruben C; Marcu, Laura

    2017-07-01

    To provide a comprehensive understanding of how the selection of radiation dose affects the temporal and spatial progression of radiation-induced necrosis in the rat model. Necrosis was induced with a single fraction of radiation exposure, at doses ranging between 20 and 60 Gy, to the right hemisphere of 8-week-old Fischer rats from a linear accelerator. The development and progression of necrosis in the rats was monitored and quantified every other week with T1- and T2-weighted gadolinium contrast-enhanced MRI studies. The time to onset of necrosis was found to be dose-dependent, but after the initial onset, the necrosis progression rate and total volume generated was constant across different doses ranging between 30 and 60 Gy. Radiation doses less than 30 Gy did not develop necrosis within 33 weeks after treatment, indicating a dose threshold existing between 20 and 30 Gy. The highest dose used in this study led to the shortest time to onset of radiation-induced necrosis, while producing comparable disease progression dynamics after the onset. Therefore, for the radiation-induced necrosis rat model using a linear accelerator, the most optimum results were generated from a dose of 60 Gy.

  3. Pharmacogenetics-based warfarin dosing algorithm decreases time to stable anticoagulation and the risk of major hemorrhage: an updated meta-analysis of randomized controlled trials.

    PubMed

    Wang, Zhi-Quan; Zhang, Rui; Zhang, Peng-Pai; Liu, Xiao-Hong; Sun, Jian; Wang, Jun; Feng, Xiang-Fei; Lu, Qiu-Fen; Li, Yi-Gang

    2015-04-01

    Warfarin is yet the most widely used oral anticoagulant for thromboembolic diseases, despite the recently emerged novel anticoagulants. However, difficulty in maintaining stable dose within the therapeutic range and subsequent serious adverse effects markedly limited its use in clinical practice. Pharmacogenetics-based warfarin dosing algorithm is a recently emerged strategy to predict the initial and maintaining dose of warfarin. However, whether this algorithm is superior over conventional clinically guided dosing algorithm remains controversial. We made a comparison of pharmacogenetics-based versus clinically guided dosing algorithm by an updated meta-analysis. We searched OVID MEDLINE, EMBASE, and the Cochrane Library for relevant citations. The primary outcome was the percentage of time in therapeutic range. The secondary outcomes were time to stable therapeutic dose and the risks of adverse events including all-cause mortality, thromboembolic events, total bleedings, and major bleedings. Eleven randomized controlled trials with 2639 participants were included. Our pooled estimates indicated that pharmacogenetics-based dosing algorithm did not improve percentage of time in therapeutic range [weighted mean difference, 4.26; 95% confidence interval (CI), -0.50 to 9.01; P = 0.08], but it significantly shortened the time to stable therapeutic dose (weighted mean difference, -8.67; 95% CI, -11.86 to -5.49; P < 0.00001). Additionally, pharmacogenetics-based algorithm significantly reduced the risk of major bleedings (odds ratio, 0.48; 95% CI, 0.23 to 0.98; P = 0.04), but it did not reduce the risks of all-cause mortality, total bleedings, or thromboembolic events. Our results suggest that pharmacogenetics-based warfarin dosing algorithm significantly improves the efficiency of International Normalized Ratio correction and reduces the risk of major hemorrhage.

  4. Individual differences in the reinforcing and punishing effects of nicotine in rhesus monkeys.

    PubMed

    Koffarnus, Mikhail N; Winger, Gail

    2015-07-01

    The relatively weak reinforcing effects of nicotine in experimental studies have been attributed to possible aversive effects or the need to space nicotine administrations over time to expose reinforcing effects. This study was designed to determine if the response-maintaining effects of nicotine are increased when availability is spaced through time, and whether nicotine is an effective punisher of remifentanil-maintained responding. Compared to a cocaine reference dose, nicotine dose and timeout (TO) value were varied in eight rhesus monkeys responding for intravenous (i.v.) nicotine on varying fixed-ratio (FR) schedules of reinforcement.The aversive effects of nicotine were evaluated in four animals choosing between a standard dose of remifentanil alone or in combination with one of several doses of nicotine. In three of eight self-administration monkeys, 0.01 mg/kg/inj nicotine did not maintain responding at any FR value. In the other five animals, nicotine-maintained response rates increased with either FR or TO values to a certain point, and then slowed. Maximum nicotine-maintained response rates were much slower than those maintained by cocaine, and demand for nicotine was less than demand for cocaine. Nicotine was an effective punisher of remifentanil-maintained responding at doses ranging from 0.01 to 0.3 mg/kg/inj. Lower punishing dose seemed to be related to the absence of reinforcing effects within subject. There are an order of magnitude individual differences in sensitivity to both the reinforcing and punishing effects of nicotine, and this drug may be unique in being a weak positive reinforcer in small doses and aversive in large doses.

  5. SU-F-T-184: 3D Range-Modulator for Scanned Particle Therapy: Development, Monte Carlo Simulations and Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Simeonov, Y; Penchev, P; Ringbaek, T Printz

    2016-06-15

    Purpose: Active raster scanning in particle therapy results in highly conformal dose distributions. Treatment time, however, is relatively high due to the large number of different iso-energy layers used. By using only one energy and the so called 3D range-modulator irradiation times of a few seconds only can be achieved, thus making delivery of homogeneous dose to moving targets (e.g. lung cancer) more reliable. Methods: A 3D range-modulator consisting of many pins with base area of 2.25 mm2 and different lengths was developed and manufactured with rapid prototyping technique. The form of the 3D range-modulator was optimised for a sphericalmore » target volume with 5 cm diameter placed at 25 cm in a water phantom. Monte Carlo simulations using the FLUKA package were carried out to evaluate the modulating effect of the 3D range-modulator and simulate the resulting dose distribution. The fine and complicated contour form of the 3D range-modulator was taken into account by a specially programmed user routine. Additionally FLUKA was extended with the capability of intensity modulated scanning. To verify the simulation results dose measurements were carried out at the Heidelberg Ion Therapy Center (HIT) with a 400.41 MeV 12C beam. Results: The high resolution measurements show that the 3D range-modulator is capable of producing homogeneous 3D conformal dose distributions, simultaneously reducing significantly irradiation time. Measured dose is in very good agreement with the previously conducted FLUKA simulations, where slight differences were traced back to minor manufacturing deviations from the perfect optimised form. Conclusion: Combined with the advantages of very short treatment time the 3D range-modulator could be an alternative to treat small to medium sized tumours (e.g. lung metastasis) with the same conformity as full raster-scanning treatment. Further simulations and measurements of more complex cases will be conducted to investigate the full potential of the 3D range-modulator.« less

  6. Gamma-dose rates from terrestrial and Chernobyl radionuclides inside and outside settlements in the Bryansk Region, Russia in 1996-2003.

    PubMed

    Ramzaev, Valery; Yonehara, Hidenori; Hille, Ralf; Barkovsky, Anatoly; Mishine, Arkady; Sahoo, Sarat Kumar; Kurotaki, Katsumi; Uchiyama, Masafumi

    2006-01-01

    In order to estimate current external gamma doses to the population of the Russian territories contaminated as a result of the Chernobyl accident, absorbed gamma-dose rates in air (DR) were determined at typical urban and suburban locations. The study was performed in the western districts of the Bryansk Region within the areas of 30 settlements (28 villages and 2 towns) with the initial levels of 137Cs deposition ranging from 13 to 4340 kBqm(-2). In the towns, the living areas considered were private one-story wooden and stone houses. DR values were derived from in situ measurements performed with the help of gamma-dosimeters and gamma-spectrometers as well as from the results of soil samples analysis. In the areas under study, the values of DR from terrestrial radionuclides were 25+/-6, 24+/-5, 50+/-10, 32+/-6, 54+/-11, 24+/-8, 20+/-6, 25+/-8, and 18+/-5 nGyh(-1) at locations of kitchen gardens, dirt surfaces, asphalt surfaces, wooden houses, stone houses, grasslands inside settlement, grasslands outside settlement, ploughed fields, and forests, respectively. In 1996-2001, mean normalized (per MBqm(-2) of 137Cs current inventory in soil) values of DR from (137)Cs were 0.41+/-0.07, 0.26+/-0.13, 0.15+/-0.07, 0.10+/-0.05, 0.05+/-0.04, 0.48+/-0.12, 1.04+/-0.22, 0.37+/-0.07, and 1.15+/-0.19 microGyh(-1) at the locations of kitchen gardens, dirt surfaces, asphalt surfaces, wooden houses, stone houses, grasslands inside settlement, grasslands outside settlement, ploughed fields, and forests, respectively. The radiometric data from this work and the values of occupancy factors determined for the Russian population by others were used for the assessments of annual effective doses to three selected groups of rural population. The normalized (per MBqm(-2) 137Cs current ground deposition) external effective doses to adults from 137Cs ranged from 0.66 to 2.27 mSvy(-1) in the years 1996-2001, in accordance with professional activities and structures of living areas. For the areas under study, the average external effective doses from 137Cs were estimated to be in the range of 0.39-1.34 mSvy(-1) in 2001. The average external effective doses from natural radionuclides appeared to be lower than those from the Chernobyl fallout ranging from 0.15 to 0.27 mSvy(-1).

  7. A 3-lever discrimination procedure reveals differences in the subjective effects of low and high doses of MDMA.

    PubMed

    Harper, David N; Langen, Anna-Lena; Schenk, Susan

    2014-01-01

    Drug discrimination studies have suggested that the subjective effects of low doses of (±)3,4-methylenedioxymethamphetamine (MDMA) are readily differentiated from those of d-amphetamine (AMPH) and that the discriminative stimulus properties are mediated by serotonergic and dopaminergic mechanisms, respectively. Previous studies, however, have primarily examined responses to doses that do not produce substantial increases in extracellular dopamine. The present study determined whether doses of MDMA that produce increases in synaptic dopamine would also produce subjective effects that were more like AMPH and were sensitive to pharmacological manipulation of D1-like receptors. A three-lever drug discrimination paradigm was used. Rats were trained to respond on different levers following saline, AMPH (0.5mg/kg, IP) or MDMA (1.5mg/kg, IP) injections. Generalization curves were generated for a range of different doses of both drugs and the effect of the D1-like antagonist, SCH23390 on the discriminative stimulus effects of different doses of MDMA was determined. Rats accurately discriminated MDMA, AMPH and saline. Low doses of MDMA produced almost exclusive responding on the MDMA lever but at doses of 3.0mg/kg MDMA or higher, responding shifted to the AMPH lever. The AMPH response produced by higher doses of MDMA was attenuated by pretreatment with SCH23390. The data suggest that low doses and higher doses of MDMA produce distinct discriminative stimuli. The shift to AMPH-like responding following administration of higher doses of MDMA, and the decrease in this response following administration of SCH23390 suggests a dopaminergic component to the subjective experience of MDMA at higher doses. Copyright © 2013 Elsevier Inc. All rights reserved.

  8. Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV

    NASA Astrophysics Data System (ADS)

    Ehringfeld, Christian; Schmid, Susanne; Poljanc, Karin; Kirisits, Christian; Aiginger, Hannes; Georg, Dietmar

    2005-01-01

    The purpose of this study was to investigate the dosimetric characteristics (energy dependence, linearity, fading, reproducibility, etc) of MOSFET detectors for in vivo dosimetry in the kV x-ray range. The experience of MOSFET in vivo dosimetry in a pre-clinical study using the Alderson phantom and in clinical practice is also reported. All measurements were performed with a Gulmay D3300 kV unit and TN-502RDI MOSFET detectors. For the determination of correction factors different solid phantoms and a calibrated Farmer-type chamber were used. The MOSFET signal was linear with applied dose in the range from 0.2 to 2 Gy for all energies. Due to fading it is recommended to read the MOSFET signal during the first 15 min after irradiation. For long time intervals between irradiation and readout the fading can vary largely with the detector. The temperature dependence of the detector signal was small (0.3% °C-1) in the temperature range between 22 and 40 °C. The variation of the measuring signal with beam incidence amounts to ±5% and should be considered in clinical applications. Finally, for entrance dose measurements energy-dependent calibration factors, correction factors for field size and irradiated cable length were applied. The overall accuracy, for all measurements, was dominated by reproducibility as a function of applied dose. During the pre-clinical in vivo study, the agreement between MOSFET and TLD measurements was well within 3%. The results of MOSFET measurements, to determine the dosimetric characteristics as well as clinical applications, showed that MOSFET detectors are suitable for in vivo dosimetry in the kV range. However, some energy-dependent dosimetry effects need to be considered and corrected for. Due to reproducibility effects at low dose levels accurate in vivo measurements are only possible if the applied dose is equal to or larger than 2 Gy.

  9. Application of commercial MOSFET detectors for in vivo dosimetry in the therapeutic x-ray range from 80 kV to 250 kV.

    PubMed

    Ehringfeld, Christian; Schmid, Susanne; Poljanc, Karin; Kirisits, Christian; Aiginger, Hannes; Georg, Dietmar

    2005-01-21

    The purpose of this study was to investigate the dosimetric characteristics (energy dependence, linearity, fading, reproducibility, etc) of MOSFET detectors for in vivo dosimetry in the kV x-ray range. The experience of MOSFET in vivo dosimetry in a pre-clinical study using the Alderson phantom and in clinical practice is also reported. All measurements were performed with a Gulmay D3300 kV unit and TN-502RDI MOSFET detectors. For the determination of correction factors different solid phantoms and a calibrated Farmer-type chamber were used. The MOSFET signal was linear with applied dose in the range from 0.2 to 2 Gy for all energies. Due to fading it is recommended to read the MOSFET signal during the first 15 min after irradiation. For long time intervals between irradiation and readout the fading can vary largely with the detector. The temperature dependence of the detector signal was small (0.3% degrees C(-1)) in the temperature range between 22 and 40 degrees C. The variation of the measuring signal with beam incidence amounts to +/-5% and should be considered in clinical applications. Finally, for entrance dose measurements energy-dependent calibration factors, correction factors for field size and irradiated cable length were applied. The overall accuracy, for all measurements, was dominated by reproducibility as a function of applied dose. During the pre-clinical in vivo study, the agreement between MOSFET and TLD measurements was well within 3%. The results of MOSFET measurements, to determine the dosimetric characteristics as well as clinical applications, showed that MOSFET detectors are suitable for in vivo dosimetry in the kV range. However, some energy-dependent dosimetry effects need to be considered and corrected for. Due to reproducibility effects at low dose levels accurate in vivo measurements are only possible if the applied dose is equal to or larger than 2 Gy.

  10. Characterization of MOSFET dosimeters for low-dose measurements in maxillofacial anthropomorphic phantoms.

    PubMed

    Koivisto, Juha H; Wolff, Jan E; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-07-08

    The aims of this study were to characterize reinforced metal-oxide-semiconductor field-effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low-dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50-90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point-dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k = 2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low-dose limit. The sensitivity was 3.09 ± 0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was -8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD-comparable low-dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low.

  11. Proteomic and Epigenetic Analysis of Rice after Seed Spaceflight and Ground-Base Ion Radiations

    NASA Astrophysics Data System (ADS)

    Wang, Wei; Sun, Yeqing; Peng, Yuming; Zhao, Qian; Wen, Bin; Yang, Jun

    Highly ionizing radiation (HZE) in space is considered as main factor causing biological effects to plant seeds. In previous work, we compared the proteomic profiles of rice plants growing after seed spaceflights to ground controls by two-dimensional difference gel electrophoresis (2-D DIGE) with mass spectrometry and found that the protein expression profiles were changed and differentially expressed proteins participated in most of the biological processes of rice. To further evaluate the dosage effects of space radiation and compare between low- and high-dose ion effects, we carried out three independent ground-base ionizing radiation experiments with different cumulative doses (low-dose range: 2~1000mGy, high-dose range: 2000~20000mGy) to rice seeds and performed proteomic analysis of seedlings. We found that protein expression profiles showed obvious boundaries between low- and high-dose radiation groups. Rates of differentially expressed proteins presented a dose-dependent effect, it reached the highest value at 2000mGy dosage point in all three radiation experiments coincidently; while proteins responded to low-dose radiations preferred to change their expressions at the minimum dosage (2mGy). Proteins participating in rice biological processes also responded differently between low- and high-dose radiations: proteins involved in energy metabolism and photosynthesis tended to be regulated after low-dose radiations while stress responding, protein folding and cell redox homeostasis related proteins preferred to change their expressions after high-dose radiations. By comparing the proteomic profiles between ground-base radiations and spaceflights, it was worth noting that ground-base low-dose ion radiation effects shared similar biological effects as space environment. In addition, we discovered that protein nucleoside diphosphate kinase 1 (NDPK1) showed obvious increased regulation after spaceflights and ion radiations. NDPK1 catalyzes nucleotide metabolism and is reported to be involved in DNA repair process. Its expression sensitivity and specificity were confirmed by RT-PCR and western blot analysis, indicating its potential to be used as space radiation biomarker. Space radiations might induce epigenetic effects on rice plants, especially changes of DNA methylation. Early results suggested that there were correlations between DNA methylation polymorphic and genomic mutation rates. In addition, the 5-methylcytosine located in coding gene’s promoter and exon regions could regulate gene expressions thus influence protein expressions. So whether there is correlation between genome DNA methylation changes and protein expression profile alterations caused by space radiation is worth for further investigation. Therefore we used the same rice samples treated by carbon ion radiation with different doses (0, 10, 20,100, 200, 1000, 2000, 5000, 20000mGy) and applied methylation sensitive amplification polymorphism (MSAP) for scanning genome DNA methylation changes. Interestingly, DNA methylation polymorphism rates also presented a dose-dependent effect and showed the same changing trend as rates of differentially expressed proteins. Whether there are correlations between epigenetic and proteomic effects of space radiation is worth for further investigation.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rafat, M; Bazalova, M; Palma, B

    Purpose: To characterize the effect of very rapid dose delivery as compared to conventional therapeutic irradiation times on clonogenic cell survival. Methods: We used a Varian Trilogy linear accelerator to deliver doses up to 10 Gy using a 6 MV SRS photon beam. We irradiated four cancer cell lines in times ranging from 30 sec to 30 min. We also used a Varian TrueBeam linear accelerator to deliver 9 MeV electrons at 10 Gy in 10 s to 30 min to determine the effect of irradiation time on cell survival. We then evaluated the effect of using 60 and 120more » MeV electrons on cell survival using the Next Linear Collider Test Accelerator (NLCTA) beam line at the SLAC National Accelerator Laboratory. During irradiation, adherent cells were maintained at 37oC with 20%O2/5%CO2. Clonogenic assays were completed following irradiation to determine changes in cell survival due to dose delivery time and beam quality, and the survival data were fitted with the linear-quadratic model. Results: Cell lines varied in radiosensitivity, ranging from two to four logs of cell kill at 10 Gy for both conventional and very rapid irradiation. Delivering radiation in shorter times decreased survival in all cell lines. Log differences in cell kill ranged from 0.2 to 0.7 at 10 Gy for the short compared to the long irradiation time. Cell kill differences between short and long irradiations were more pronounced as doses increased for all cell lines. Conclusion: Our findings suggest that shortening delivery of therapeutic radiation doses to less than 1 minute may improve tumor cell kill. This study demonstrates the potential advantage of technologies under development to deliver stereotactic ablative radiation doses very rapidly. Bill Loo and Peter Maxim have received Honoraria from Varian and Research Support from Varian and RaySearch.« less

  13. Evaluation of the effect of prostate volume change on tumor control probability in LDR brachytherapy.

    PubMed

    Knaup, Courtney; Mavroidis, Panayiotis; Stathakis, Sotirios; Smith, Mark; Swanson, Gregory; Papanikolaou, Niko

    2011-09-01

    This study evaluates low dose-rate brachytherapy (LDR) prostate plans to determine the biological effect of dose degradation due to prostate volume changes. In this study, 39 patients were evaluated. Pre-implant prostate volume was determined using ultrasound. These images were used with the treatment planning system (Nucletron Spot Pro 3.1(®)) to create treatment plans using (103)Pd seeds. Following the implant, patients were imaged using CT for post-implant dosimetry. From the pre and post-implant DVHs, the biologically equivalent dose and the tumor control probability (TCP) were determined using the biologically effective uniform dose. The model used RBE = 1.75 and α/β = 2 Gy. The prostate volume changed between pre and post implant image sets ranged from -8% to 110%. TCP and the mean dose were reduced up to 21% and 56%, respectively. TCP is observed to decrease as the mean dose decreases to the prostate. The post-implant tumor dose was generally observed to decrease, compared to the planned dose. A critical uniform dose of 130 Gy was established. Below this dose, TCP begins to fall-off. It was also determined that patients with a small prostates were more likely to suffer TCP decrease. The biological effect of post operative prostate growth due to operative trauma in LDR was evaluated using the concept. The post-implant dose was lower than the planned dose due to an increase of prostate volume post-implant. A critical uniform dose of 130 Gy was determined, below which TCP begun to decline.

  14. Study on the Dose Uncertainties in the Lung during Passive Proton Irradiation with a Proton Beam Range Compensator

    NASA Astrophysics Data System (ADS)

    Yoo, Seung Hoon; Son, Jae Man; Yoon, Myonggeun; Park, Sung Yong; Shin, Dongho; Min, Byung Jun

    2018-06-01

    A moving phantom is manufactured for mimicking lung model to study the dose uncertainty from CT number-stopping power conversion and dose calculation in the soft tissue, light lung tissue and bone regions during passive proton irradiation with compensator smearing value. The phantom is scanned with a CT system, and a proton beam irradiation plan is carried out with the use of a treatment planning system (Eclipse). In the case of the moving phantom, a RPM system is used for respiratory gating. The uncertainties in the dose distribution between the measured data and the planned data are investigated by a gamma analysis with 3%-3 mm acceptance criteria. To investigate smearing effect, three smearing values (0.3 cm, 0.7 cm, 1.2 cm) are used to for fixed and moving phantom system. For both fixed and moving phantom, uncertainties in the light lung tissue are severe than those in soft tissue region in which the dose uncertainties are within clinically tolerable ranges. As the smearing value increases, the uncertainty in the proton dose distribution decreases.

  15. NOTE: Investigating the potential of polymer gel dosimetry for interventional radiology: first results

    NASA Astrophysics Data System (ADS)

    Antoniou, P. E.; Bousbouras, P.; Sandaltzopoulos, R.; Kaldoudi, E.

    2008-04-01

    Complex interventional radiology (IR) procedures contribute an increasing percentage of the overall medical radiation exposure of the population making accurate dosimetry a challenge. Magnetic resonance (MR) based polymer gel dosimetry has been widely employed in complex dosimetric problems in radiotherapy. The aim of this note is to investigate the feasibility of normoxic gel dosimetry in IR. Dose response, energy dependence and dose rate dependence were investigated in irradiation set-ups relevant to IR for a particular normoxic gel, based on methacrylic acid (MAA) as the monomer and including tetrakis-hydroxy-methyl-phosphonium chloride (THPC) as antioxidant. The gel presents a linear dose response beyond a 25 cGy threshold. No significant energy dependence was observed in the useful range of interventional radiology (80-110 kVp). A linear correlation between the gel response and dose rate was observed in the range of dose rates relevant to IR (5-8 cGy min-1). These results demonstrate a reduction of gel sensitivity at very low dose rate levels. A possible explanation of this effect is suggested.

  16. IMRT and RapidArc commissioning of a TrueBeam linear accelerator using TG-119 protocol cases.

    PubMed

    Wen, Ning; Zhao, Bo; Kim, Jinkoo; Chin-Snyder, Karen; Bellon, Maria; Glide-Hurst, Carri; Barton, Kenneth; Chen, Daiquan; Chetty, Indrin J

    2014-09-08

    The purpose of this study is to evaluate the overall accuracy of intensity-modulated radiation therapy (IMRT) and RapidArc delivery using both flattening filter (FF) and flattening filter-free (FFF) modalities based on test cases developed by AAPM Task Group 119. Institutional confidence limits (CLs) were established as the baseline for patient specific treatment plan quality assurance (QA). The effects of gantry range, gantry speed, leaf speed, dose rate, as well as the capability to capture intentional errors, were evaluated by measuring a series of Picket Fence (PF) tests using the electronic portal imaging device (EPID) and EBT3 films. Both IMRT and RapidArc plans were created in a Solid Water phantom (30 × 30 × 15 cm3) for the TG-119 test cases representative of normal clinical treatment sites for all five photon energies (6X, 10X, 15X, 6X-FFF, 10X-FFF) and the Exact IGRT couch was included in the dose calculation. One high-dose point in the PTV and one low-dose point in the avoidance structure were measured with an ion chamber in each case for each energy. Similarly, two GAFCHROMIC EBT3 films were placed in the coronal planes to measure planar dose distributions in both high- and low-dose regions. The confidence limit was set to have 95% of the measured data fall within the tolerance. The mean of the absolute dose deviation for variable dose rate and gantry speed during RapidArc delivery was within 0.5% for all energies. The corresponding results for leaf speed tests were all within 0.4%. The combinations of dynamic leaf gap (DLG) and MLC transmission factor were optimized based on the ion chamber measurement results of RapidArc delivery for each energy. The average 95% CLs for the high-dose point in the PTV were 0.030 ± 0.007 (range, 0.022-0.038) for the IMRT plans and 0.029 ± 0.011 (range, 0.016-0.043) for the RapidArc plans. For low-point dose in the avoidance structures, the CLs were 0.029 ± 0.006 (range, 0.024-0.039) for the IMRT plans and 0.027 ± 0.013 (range, 0.017-0.047) for the RapidArc plans. The average 95% CLs using 3%/3 mm gamma criteria in the high-dose region were 5.9 ± 2.7 (range, 1.4-8.6) and 3.9 ± 2.9 (range, 1.5-8.8) for IMRT and RapidArc plans, respectively. The average 95% CLs in the low-dose region were 5.3 ± 2.6 (range, 1.2-7.4) and 3.7 ± 2.8 (range, 1.8-8.3) for IMRT and RapidArc plans, respectively. Based on ion chamber, as well as film measurements, we have established CLs values to ensure the high precision of IMRT and RapidArc delivery for both FF and FFF modalities.

  17. Experimentally studied dynamic dose interplay does not meaningfully affect target dose in VMAT SBRT lung treatments.

    PubMed

    Stambaugh, Cassandra; Nelms, Benjamin E; Dilling, Thomas; Stevens, Craig; Latifi, Kujtim; Zhang, Geoffrey; Moros, Eduardo; Feygelman, Vladimir

    2013-09-01

    The effects of respiratory motion on the tumor dose can be divided into the gradient and interplay effects. While the interplay effect is likely to average out over a large number of fractions, it may play a role in hypofractionated [stereotactic body radiation therapy (SBRT)] treatments. This subject has been extensively studied for intensity modulated radiation therapy but less so for volumetric modulated arc therapy (VMAT), particularly in application to hypofractionated regimens. Also, no experimental study has provided full four-dimensional (4D) dose reconstruction in this scenario. The authors demonstrate how a recently described motion perturbation method, with full 4D dose reconstruction, is applied to describe the gradient and interplay effects during VMAT lung SBRT treatments. VMAT dose delivered to a moving target in a patient can be reconstructed by applying perturbations to the treatment planning system-calculated static 3D dose. Ten SBRT patients treated with 6 MV VMAT beams in five fractions were selected. The target motion (motion kernel) was approximated by 3D rigid body translation, with the tumor centroids defined on the ten phases of the 4DCT. The motion was assumed to be periodic, with the period T being an average from the empirical 4DCT respiratory trace. The real observed tumor motion (total displacement ≤ 8 mm) was evaluated first. Then, the motion range was artificially increased to 2 or 3 cm. Finally, T was increased to 60 s. While not realistic, making T comparable to the delivery time elucidates if the interplay effect can be observed. For a single fraction, the authors quantified the interplay effect as the maximum difference in the target dosimetric indices, most importantly the near-minimum dose (D99%), between all possible starting phases. For the three- and five-fractions, statistical simulations were performed when substantial interplay was found. For the motion amplitudes and periods obtained from the 4DCT, the interplay effect is negligible (<0.2%). It is also small (0.9% average, 2.2% maximum) when the target excursion increased to 2-3 cm. Only with large motion and increased period (60 s) was a significant interplay effect observed, with D99% ranging from 16% low to 17% high. The interplay effect was statistically significantly lower for the three- and five-fraction statistical simulations. Overall, the gradient effect dominates the clinical situation. A novel method was used to reconstruct the volumetric dose to a moving tumor during lung SBRT VMAT deliveries. With the studied planning and treatment technique for realistic motion periods, regardless of the amplitude, the interplay has nearly no impact on the near-minimum dose. The interplay effect was observed, for study purposes only, with the period comparable to the VMAT delivery time.

  18. Determining organ dose conversion coefficients for external neutron irradiation by using a voxel mouse model

    PubMed Central

    Zhang, Xiaomin; Xie, Xiangdong; Qu, Decheng; Ning, Jing; Zhou, Hongmei; Pan, Jie; Yang, Guoshan

    2016-01-01

    A set of fluence-to-dose conversion coefficients has been calculated for neutrons with energies <20 MeV using a developed voxel mouse model and Monte Carlo N-particle code (MCNP), for the purpose of neutron radiation effect evaluation. The calculation used 37 monodirectional monoenergetic neutron beams in the energy range 10−9 MeV to 20 MeV, under five different source irradiation configurations: left lateral, right lateral, dorsal–ventral, ventral–dorsal, and isotropic. Neutron fluence-to-dose conversion coefficients for selected organs of the body were presented in the paper, and the effect of irradiation geometry conditions, neutron energy and the organ location on the organ dose was discussed. The results indicated that neutron dose conversion coefficients clearly show sensitivity to irradiation geometry at neutron energy below 1 MeV. PMID:26661852

  19. Dose and Dose Risk Caused by Natural Phenomena - Proposed Powder Metallurgy Core Manufacturing Facility

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, W.G.

    2001-08-16

    The offsite radiological effects from high velocity straight winds, tornadoes, and earthquakes have been estimated for a proposed facility for manufacturing enriched uranium fuel cores by powder metallurgy. Projected doses range up to 30 mrem/event to the maximum offsite individual for high winds and up to 85 mrem/event for very severe earthquakes. Even under conservative assumptions on meteorological conditions, the maximum offsite dose would be about 20 per cent of the DOE limit for accidents involving enriched uranium storage facilities. The total dose risk is low and is dominated by the risk from earthquakes. This report discusses this test.

  20. Sub-dissociative-dose intranasal ketamine for moderate to severe pain in adult emergency department patients.

    PubMed

    Yeaman, Fiona; Meek, Robert; Egerton-Warburton, Diana; Rosengarten, Pamela; Graudins, Andis

    2014-06-01

    There are currently no studies assessing effectiveness of sub-dissociative intranasal (IN) ketamine as the initial analgesic for adult patients in the ED. The study aims to examine the effectiveness of sub-dissociative IN ketamine as a primary analgesic agent for adult patients in the ED. This is a prospective, observational study of adult ED patients presenting with severe pain (≥6 on 11-point scale at triage). IN ketamine dose was 0.7 mg/kg, with secondary dose of 0.5 mg/kg at 15 min if pain did not improve. After 6 months, initial dose was increased to 1.0 mg/kg with the same optional secondary dose. The primary outcomes are change in VAS rating at 30 min; percentage of patients reporting clinically significant reduction in VAS (≥20 mm) at 30 min; dose resulting in clinically significant pain reduction. Of the 72 patients available for analysis, median age was 34.5 years and 64% were men. Median initial VAS rating was 76 mm (interquartile range [IQR]: 65-82). Median total dose of IN ketamine for all patients was 0.98 mg/kg (IQR: 0.75-1.15, range: 0.59-1.57). Median reduction in VAS rating at 30 min was 24 mm (IQR: 2-45). Forty (56%, 95% CI: 44.0-66.7) reported VAS reduction ≥20 mm, these patients having had a total median ketamine dose of 0.94 mg/kg (IQR: 0.72-1.04). IN ketamine, at a dose of about 1 mg/kg, was an effective analgesic agent in 56% of study patients. The place of IN ketamine in analgesic guidelines for adults requires further investigation. © 2014 Australasian College for Emergency Medicine and Australasian Society for Emergency Medicine.

  1. DISRUPTION OF CONDITIONED REWARD ASSOCIATION BY TYPICAL AND ATYPICAL ANTIPSYCHOTICS

    PubMed Central

    Danna, C.L.; Elmer, G.I.

    2013-01-01

    Antipsychotic drugs are broadly classified into typical and atypical compounds; they vary in their pharmacological profile however a common component is their antagonist effects at the D2 dopamine receptors (DRD2). Unfortunately, diminished DRD2 activation is generally thought to be associated with the severity of neuroleptic-induced anhedonia. The purpose of this study was to determine the effect of the atypical antipsychotic olanzapine and typical antipsychotic haloperidol in a paradigm that reflects the learned transfer of incentive motivational properties to previously neutral stimuli, namely autoshaping. In order to provide a dosing comparison to a therapeutically relevant endpoint, both drugs were tested against amphetamine-induced disruption of prepulse inhibition as well. In the autoshaping task, rats were exposed to repeated pairings of stimuli that were differentially predictive of reward delivery. Conditioned approach to the reward predictive cue (sign-tracking) and to the reward (goal-tracking) increased during repeated pairings in the vehicle treated rats. Haloperidol and olanzapine completely abolished this behavior at relatively low doses (100 μg/kg). This same dose was the threshold dose for each drug to antagonize the sensorimotor gating deficits produced by amphetamine. At lower doses (3–30 μg/kg) both drugs produced a dose-dependent decrease in conditioned approach to the reward predictive cue. There was no difference between drugs at this dose range which indicates that olanzapine disrupts autoshaping at a significantly lower proposed DRD2 receptor occupancy. Interestingly, neither drug disrupted conditioned approach to the reward at the same dose range that disrupted conditioned approach to the reward predictive cue. Thus, haloperidol and olanzapine, at doses well below what is considered therapeutically relevant, disrupts the attribution of incentive motivational value to previously neutral cues. Drug effects on this dimension of reward processing are an important consideration in the development of future pharmacological treatments for schizophrenia. PMID:20416333

  2. alpha-Adrenoceptor and opioid receptor modulation of clonidine-induced antinociception.

    PubMed Central

    Sierralta, F.; Naquira, D.; Pinardi, G.; Miranda, H. F.

    1996-01-01

    1. The antinociceptive action of clonidine (Clon) and the interactions with alpha 1, alpha 2 adrenoceptor and opioid receptor antagonists was evaluated in mice by use of chemical algesiometric test (acetic acid writhing test). 2. Clon produced a dose-dependent antinociceptive action and the ED50 for intracerebroventricular (i.c.v.) was lower than for intraperitoneal (i.p.) administration (1 ng kg-1 vs 300 ng kg-1). The parallelism of the dose-response curves indicates activation of a common receptor subtype. 3. Systemic administration of prazosin and terazosin displayed antinociceptive activity. Pretreatment with prazosin produced a dual action: i.c.v. Clon effect did not change, and i.p. Clon effect was enhanced. Yohimbine i.c.v. or i.p. did not induce antinonciception, but antagonized Clon-induced activity. These results suggest that alpha 1- and alpha 2-adrenoceptors, either located at the pre- and/or post-synaptic level, are involved in the control of spinal antinociception. 4. Naloxone (NX) and naltrexone (NTX) induced antinociceptive effects at low doses (microgram kg-1 range) and a lower antinociceptive effect at higher doses (mg kg-1 range). Low doses of NX or NTX antagonized Clon antinociception, possibly in relation to a preferential mu opioid receptor antagonism. In contrast, high doses of NX or NTX increased the antinociceptive activity of Clon, which could be due to an enhanced inhibition of the release of substance P. 5. The results obtained in the present work suggest the involvement of alpha 1-, alpha 2-adrenoceptor and opioid receptors in the modulation of the antinociceptive activity of clonidine, which seems to be exerted either at spinal and/or supraspinal level. PMID:8894177

  3. alpha-Adrenoceptor and opioid receptor modulation of clonidine-induced antinociception.

    PubMed

    Sierralta, F; Naquira, D; Pinardi, G; Miranda, H F

    1996-10-01

    1. The antinociceptive action of clonidine (Clon) and the interactions with alpha 1, alpha 2 adrenoceptor and opioid receptor antagonists was evaluated in mice by use of chemical algesiometric test (acetic acid writhing test). 2. Clon produced a dose-dependent antinociceptive action and the ED50 for intracerebroventricular (i.c.v.) was lower than for intraperitoneal (i.p.) administration (1 ng kg-1 vs 300 ng kg-1). The parallelism of the dose-response curves indicates activation of a common receptor subtype. 3. Systemic administration of prazosin and terazosin displayed antinociceptive activity. Pretreatment with prazosin produced a dual action: i.c.v. Clon effect did not change, and i.p. Clon effect was enhanced. Yohimbine i.c.v. or i.p. did not induce antinonciception, but antagonized Clon-induced activity. These results suggest that alpha 1- and alpha 2-adrenoceptors, either located at the pre- and/or post-synaptic level, are involved in the control of spinal antinociception. 4. Naloxone (NX) and naltrexone (NTX) induced antinociceptive effects at low doses (microgram kg-1 range) and a lower antinociceptive effect at higher doses (mg kg-1 range). Low doses of NX or NTX antagonized Clon antinociception, possibly in relation to a preferential mu opioid receptor antagonism. In contrast, high doses of NX or NTX increased the antinociceptive activity of Clon, which could be due to an enhanced inhibition of the release of substance P. 5. The results obtained in the present work suggest the involvement of alpha 1-, alpha 2-adrenoceptor and opioid receptors in the modulation of the antinociceptive activity of clonidine, which seems to be exerted either at spinal and/or supraspinal level.

  4. A comparative study of the effects of Escherichia coli and Clostridium perfringens upon boar semen preserved in liquid storage.

    PubMed

    Pinart, Elisabeth; Domènech, Esther; Bussalleu, Eva; Yeste, Marc; Bonet, Sergi

    2017-02-01

    The present study compares the sperm quality of boar seminal doses artificially inoculated with Escherichia coli and Clostridium perfringens, and maintained in liquid storage at 15°C for a 9-day period. Seminal doses from 10 sexually mature Piétrain boars were diluted in a Beltsville Thawing Solution (BTS)-based extender and infected either with E. coli or C. perfringens, with bacterial loads ranging from 10 1 to 10 7 cfumL -1 . During storage, the changes in sperm quality were determined by assessing pH, sperm viability, sperm motiliy, sperm morphology, sperm agglutination degree, and sperm-bacteria interaction. The infection of seminal doses led to an alkalinization of the medium, which was of higher extend in doses infected with C. perfringens. The effect of contamination on sperm viability and motility relied on bacterial type and load. Therefore, while E. coli was more harmful than C. perfringens in bacterial loads ranging from 10 1 to 10 6 cfumL -1 , the detrimental impact of C. perfringens was more apparent than that of E. coli at a bacterial load of 10 7 cfumL -1 . Despite sperm morphology not being affected by either bacterial type or load, sperm agglutination and sperm-bacteria interaction were characteristic of doses infected with E. coli, and increased concomintantly with bacterial load and along storage period. In conclusion, the effects of infection by E. coli on sperm quality were dependent of both bacterial load and storage period, whereas the effects of C. perfringens were mainly dependent on the bacterial load, with a threshold at 10 7 cfumL -1 from which the sperm quality of seminal doses was greatly impaired. Copyright © 2016 Elsevier B.V. All rights reserved.

  5. The Effects of Carbohydrates, in Isolation and Combined with Caffeine, on Cognitive Performance and Mood—Current Evidence and Future Directions

    PubMed Central

    Lawton, Clare Louise

    2018-01-01

    This review examines the effects of carbohydrates, delivered individually and in combination with caffeine, on a range of cognitive domains and subjective mood. There is evidence for beneficial effects of glucose at a dose of 25 g on episodic memory, but exploration of dose effects has not been systematic and the effects on other cognitive domains is not known. Factors contributing to the differential sensitivity to glucose facilitation include age, task difficulty/demand, task domain, and glucoregulatory control. There is modest evidence to suggest modulating glycemic response may impact cognitive function. The evidence presented in this review identifies dose ranges of glucose and caffeine which improve cognition, but fails to find convincing consistent synergistic effects of combining caffeine and glucose. Whilst combining glucose and caffeine has been shown to facilitate cognitive performance and mood compared to placebo or glucose alone, the relative contribution of caffeine and glucose to the observed effects is difficult to ascertain, due to the paucity of studies that have appropriately compared the effects of these ingredients combined and in isolation. This review identifies a number of methodological challenges which need to be considered in the design of future hypothesis driven research in this area. PMID:29425182

  6. A comparison of newborn stylized and tomographic models for dose assessment in paediatric radiology

    NASA Astrophysics Data System (ADS)

    Staton, R. J.; Pazik, F. D.; Nipper, J. C.; Williams, J. L.; Bolch, W. E.

    2003-04-01

    Establishment of organ doses from diagnostic and interventional examinations is a key component to quantifying the radiation risks from medical exposures and for formulating corresponding dose-reduction strategies. Radiation transport models of human anatomy provide a convenient method for simulating radiological examinations. At present, two classes of models exist: stylized mathematical models and tomographic voxel models. In the present study, organ dose comparisons are made for projection radiographs of both a stylized and a tomographic model of the newborn patient. Sixteen separate radiographs were simulated for each model at x-ray technique factors typical of newborn examinations: chest, abdomen, thorax and head views in the AP, PA, left LAT and right LAT projection orientation. For AP and PA radiographs of the torso (chest, abdomen and thorax views), the effective dose assessed for the tomographic model exceeds that for the stylized model with per cent differences ranging from 19% (AP abdominal view) to 43% AP chest view. In contrast, the effective dose for the stylized model exceeds that for the tomographic model for all eight lateral views including those of the head, with per cent differences ranging from 9% (LLAT chest view) to 51% (RLAT thorax view). While organ positioning differences do exist between the models, a major factor contributing to differences in effective dose is the models' exterior trunk shape. In the tomographic model, a more elliptical shape is seen thus providing for less tissue shielding for internal organs in the AP and PA directions, with corresponding increased tissue shielding in the lateral directions. This observation is opposite of that seen in comparisons of stylized and tomographic models of the adult.

  7. Radiation absorbed dose estimates for 18F-BPA PET.

    PubMed

    Kono, Yuzuru; Kurihara, Hiroaki; Kawamoto, Hiroshi; Yasui, Naoko; Honda, Naoki; Igaki, Hiroshi; Itami, Jun

    2017-09-01

    Background Boron neutron capture therapy (BNCT) is a molecular radiation therapy approach based on the 10 B (n, α) 7 Li nuclear reaction in cancer cells. In BNCT, delivery of 10 B in the form of 4-borono-phenylalanine conjugated with fructose (BPA-fr) to the cancer cells is important. The PET tracer 4-borono-2-18F-fluoro-phenylalanine (FBPA) has been used to predict the accumulation of BPA-fr before BNCT. Purpose To determine the biodistribution and dosimetric parameters in 18F-BPA PET/CT studies. Material and Methods Human biokinetic data were obtained during clinical 18F-BPA PET studies between February and June 2015 at one institution. Nine consecutive patients were studied prospectively. The internal radiation dose was calculated on the basis of radioactivity data from blood, urine, and normal tissue of the heart, liver, spleen, kidney, and other parts of the body at each time point using OLINDA/EXM1.1 program. We compared our calculations with published 18F-FDG data. Results Adult patients (3 men, 3 women; age range, 28-68 years) had significantly smaller absorbed doses than pediatric patients (3 patients; age range, 5-12 years) ( P = 0.003). The mean effective dose was 57% lower in adult patients compared with pediatric patients. Mean effective doses for 18F-BPA were 25% lower than those for 18F-FDG presented in International Commission of Radiation Protection (ICRP) publication 106. Conclusion We found significant differences in organ absorbed doses for 18F-BPA against those for 18F-FDG presented in ICRP publication 106. Mean effective doses for 18F-BPA were smaller than those for 18F-FDG in the publication by 0.5-38% (mean difference, 25%).

  8. Dosimetric characterization of a single crystal diamond detector in X-ray beams for preclinical research.

    PubMed

    Kampfer, Severin; Cho, Nathan; Combs, Stephanie E; Wilkens, Jan J

    2018-05-29

    The aim of this study was to investigate a single crystal diamond detector, the microDiamond detector from PTW (PTW-Freiburg, Freiburg, Germany), concerning the particular requirements in the set-up and energy range used in small animal radiotherapy (RT) research (around 220kV). We tested it to find out the minimal required pre-irradiation dose, the dose linearity, dose rate dependency and the angular response as well as usability in the small animal radiation research platform, SARRP (Xstrahl Ltd., Camberley, UK). For a stable signal in the range of energies used in the study, we found a required pre-irradiation dose of 10Gy. The dose linearity and dose rate dependence measurements showed a very good performance of the microDiamond detector. Regarding the effect of angular dependency, the variation of the response signal is less than 0.5% within the first 15° of the polar angle. In the azimuthal angle, however, there are differences in detector response up to 20%, depending on the range of energies used in the study. In addition, we compared the detector to a radiosensitive film for a profile measurement of a 5×5mm 2 irradiation field. Both methods showed a good accordance with the field size, however, the film has a steeper dose gradient in the penumbra region but also a higher noise than the microDiamond detector. We demonstrated that the microDiamond detector is a useful measurement tool for small animal RT research due to its small size. Nevertheless, it seems to be very important to verify the response of the detector in the given set-up and energy range. Copyright © 2018. Published by Elsevier GmbH.

  9. Effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation: phantom study.

    PubMed

    Schindera, Sebastian T; Nelson, Rendon C; Toth, Thomas L; Nguyen, Giao T; Toncheva, Greta I; DeLong, David M; Yoshizumi, Terry T

    2008-02-01

    The purpose of this study was to evaluate in a phantom study the effect of patient size on radiation dose for abdominal MDCT with automatic tube current modulation. One or two 4-cm-thick circumferential layers of fat-equivalent material were added to the abdomen of an anthropomorphic phantom to simulate patients of three sizes: small (cross-sectional dimensions, 18 x 22 cm), average size (26 x 30 cm), and oversize (34 x 38 cm). Imaging was performed with a 64-MDCT scanner with combined z-axis and xy-axis tube current modulation according to two protocols: protocol A had a noise index of 12.5 H, and protocol B, 15.0 H. Radiation doses to three abdominal organs and the skin were assessed. Image noise also was measured. Despite increasing patient size, the image noise measured was similar for protocol A (range, 11.7-12.2 H) and protocol B (range, 13.9-14.8 H) (p > 0.05). With the two protocols, in comparison with the dose of the small patient, the abdominal organ doses of the average-sized patient and the oversized patient increased 161.5-190.6%and 426.9-528.1%, respectively (p < 0.001). The skin dose increased as much as 268.6% for the average-sized patient and 816.3% for the oversized patient compared with the small patient (p < 0.001). Oversized patients undergoing abdominal MDCT with tube current modulation receive significantly higher doses than do small patients. The noise index needs to be adjusted to the body habitus to ensure dose efficiency.

  10. SU-F-T-157: Physics Considerations Regarding Dosimetric Accuracy of Analytical Dose Calculations for Small Field Proton Therapy: A Monte Carlo Study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Geng, C; Nanjing University of Aeronautics and Astronautics, Nanjing; Daartz, J

    Purpose: To evaluate the accuracy of dose calculations by analytical dose calculation methods (ADC) for small field proton therapy in a gantry based passive scattering facility. Methods: 50 patients with intra-cranial disease were evaluated in the study. Treatment plans followed standard prescription and optimization procedures of proton stereotactic radiosurgery. Dose distributions calculated with the Monte Carlo (MC) toolkit TOPAS were used to represent delivered treatments. The MC dose was first adjusted using the output factor (OF) applied clinically. This factor is determined from the field size and the prescribed range. We then introduced a normalization factor to measure the differencemore » in mean dose between the delivered dose (MC dose with OF) and the dose calculated by ADC for each beam. The normalization was determined by the mean dose of the center voxels of the target area. We compared delivered dose distributions and those calculated by ADC in terms of dose volume histogram parameters and beam range distributions. Results: The mean target dose for a whole treatment is generally within 5% comparing delivered dose (MC dose with OF) and ADC dose. However, the differences can be as great as 11% for shallow and small target treated with a thick range compensator. Applying the normalization factor to the MC dose with OF can reduce the mean dose difference to less than 3%. Considering range uncertainties, the generally applied margins (3.5% of the prescribed range + 1mm) to cover uncertainties in range might not be sufficient to guarantee tumor coverage. The range difference for R90 (90% distal dose falloff) is affected by multiple factors, such as the heterogeneity index. Conclusion: This study indicates insufficient accuracy calculating proton doses using ADC. Our results suggest that uncertainties of target doses are reduced using MC techniques, improving the dosimetric accuracy for proton stereotactic radiosurgery. The work was supported by NIH/NCI under CA U19 021239. CG was partially supported by the Chinese Scholarship Council (CSC) and the National Natural Science Foundation of China (Grant No. 11475087).« less

  11. The interplay between dose and immune system activation determines fungal infection outcome in the African malaria mosquito, Anopheles gambiae.

    PubMed

    Rhodes, Victoria L; Thomas, Matthew B; Michel, Kristin

    2018-08-01

    The Toll pathway is a central regulator of antifungal immunity in insects. In mosquitoes, the Toll pathway affects infections with the fungal entomopathogen, Beauveria bassiana, which is considered a potential mosquito biopesticide. We report here the use of B. bassiana strain I93-825 in Anopheles gambiae to analyze the impact of Toll pathway modulation on mosquito survival. Exposure to a narrow dose range of conidia by direct contact decreased mosquito longevity and median survival. In addition, fungal exposure dose correlated positively and linearly with hazard ratio. Increased Toll signaling by knockdown of its inhibitor, cactus, decreased survivorship of uninfected females, increased mosquito survival after low dose B. bassiana exposure, but had little effect following exposure to higher doses. This observed trade-off could have implications for development of B. bassiana as a prospective vector control tool. On the one hand, selection for small increases in mosquito immune signaling across a narrow dose range could impair efficacy of B. bassiana. On the other hand, costs of immunity and the capacity for higher doses of fungus to overwhelm immune responses could limit evolution of resistance. Copyright © 2018 Elsevier Ltd. All rights reserved.

  12. Comparison of buprenorphine and methadone effects on opiate self-administration in primates.

    PubMed

    Mello, N K; Bree, M P; Mendelson, J H

    1983-05-01

    The effects of ascending and descending doses of buprenorphine (0.014-0.789 mg/kg/day) and methadone (0.179-11.86 mg/kg/day) on opiate and food intake were studied in Macaque monkeys over 195 to 245 days. Food (1-g banana pellets) and i.v. drug self-administration (heroin 0.01 or 0.02 mg/kg/injection or Dilaudid 0.02 mg/kg/injection) were maintained on a second-order schedule of reinforcement [FR 4 (VR 16:S)]. Buprenorphine (0.282-0.789 mg/kg/day) produced a significant suppression of opiate self-administration at 2.5 to 7 times the dose shown to be effective in human opiate abusers (P less than .05-.001). Methadone (1.43-11.86 mg/kg/day) did not suppress opiate self-administration in four of five monkeys across a dose range equivalent to 100 to 800 mg/day in man. The distribution of opiate self-administration across drug sessions did not account for the absence of methadone suppression as monkeys took 43% of the total daily opiate injections during the first daily drug session, 2.5 hr after methadone administration. During buprenorphine maintenance, food intake remained stable or increased significantly above base-line levels. Methadone maintenance was associated with significant decrements in food intake in four of five monkeys. Buprenorphine appeared to be significantly more effective in suppressing opiate self-administration than methadone across the dose range studied. Buprenorphine had none of the toxic side effects (seizures, respiratory depression, profound psychomotor retardation) associated with high doses of methadone over 6 to 8 months of daily drug treatment. These data are consistent with clinical studies of buprenorphine effects on heroin self-administration in human opiate addicts.

  13. Cost Effectiveness of Genotype-Guided Warfarin Dosing in Patients with Mechanical Heart Valve Replacement Under the Fee-for-Service System.

    PubMed

    Kim, Dong-Jin; Kim, Ho-Sook; Oh, Minkyung; Kim, Eun-Young; Shin, Jae-Gook

    2017-10-01

    Although studies assessing the cost effectiveness of genotype-guided warfarin dosing for the management of atrial fibrillation, deep vein thrombosis, and pulmonary embolism have been reported, no publications have addressed genotype-guided warfarin therapy in mechanical heart valve replacement (MHVR) patients or genotype-guided warfarin therapy under the fee-for-service (FFS) insurance system. The aim of this study was to evaluate the cost effectiveness of genotype-guided warfarin dosing in patients with MHVR under the FFS system from the Korea healthcare sector perspective. A decision-analytic Markov model was developed to evaluate the cost effectiveness of genotype-guided warfarin dosing compared with standard dosing. Estimates of clinical adverse event rates and health state utilities were derived from the published literature. The outcome measure was the incremental cost-effectiveness ratio (ICER) per quality-adjusted life-year (QALY). One-way and probabilistic sensitivity analyses were performed to explore the range of plausible results. In a base-case analysis, genotype-guided warfarin dosing was associated with marginally higher QALYs than standard warfarin dosing (6.088 vs. 6.083, respectively), at a slightly higher cost (US$6.8) (year 2016 values). The ICER was US$1356.2 per QALY gained. In probabilistic sensitivity analysis, there was an 82.7% probability that genotype-guided dosing was dominant compared with standard dosing, and a 99.8% probability that it was cost effective at a willingness-to-pay threshold of US$50,000 per QALY gained. Compared with only standard warfarin therapy, genotype-guided warfarin dosing was cost effective in MHVR patients under the FFS insurance system.

  14. Radical-intent hypofractionated radiotherapy for locally advanced non-small-cell lung cancer: a systematic review of the literature.

    PubMed

    Kaster, Tyler S; Yaremko, Brian; Palma, David A; Rodrigues, George B

    2015-03-01

    To identify survival and toxicity characteristics associated with radical-intent hypofractionated radiotherapy for the treatment of stage III non-small-cell lung cancer (NSCLC). Relevant studies were identified from a systematic PubMed search of articles published between January 1990 and January 2014. All studies were peer reviewed and included both retrospective and prospective studies of NSCLC patients being treated with radical hypofractionated radiotherapy. Data on overall survival (OS) and toxicity were extracted from each of the studies where available. Of 685 studies initially identified by the search, a total of 33 studies were found to be relevant and were included in this systematic review. The number of fractions ranged from 15 to 35, the dose per fraction ranged from 2.3 to 3.5 Gy, and the delivered dose ranged from 45.0 to 85.5 Gy. Fifteen of the studies included concurrent chemotherapy, while 18 did not. OS was found to be associated with tumor biological effective dose, with the Pearson correlation coefficient ranging from 0.34 to 0.48. For both concurrent and nonconcurrent chemoradiotherapy acute pulmonary, late esophageal and late pulmonary incidences of toxicity ranged from 1.2% to 12.2%, but had 95% confidence intervals that included zero. The greatest incidence of toxicity was acute esophageal toxicity at 14.9% (95% confidence interval, 0.7%, 29.1%). There is a moderate linear relationship between biological effective dose and OS, and greater acute esophageal toxicity with concurrent chemotherapy. Improving outcomes in stage III NSCLC may involve some form of hypofractionation in the context of systemic concurrent therapy. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Relative Impact of Incorporating Pharmacokinetics on ...

    EPA Pesticide Factsheets

    The use of high-throughput in vitro assays has been proposed to play a significant role in the future of toxicity testing. In this study, rat hepatic metabolic clearance and plasma protein binding were measured for 59 ToxCast phase I chemicals. Computational in vitro-to-in vivo extrapolation was used to estimate the daily dose in a rat, called the oral equivalent dose, which would result in steady-state in vivo blood concentrations equivalent to the AC50 or lowest effective concentration (LEC) across more than 600 ToxCast phase I in vitro assays. Statistical classification analysis was performed using either oral equivalent doses or unadjusted AC50/LEC values for the in vitro assays to predict the in vivo effects of the 59 chemicals. Adjusting the in vitro assays for pharmacokinetics did not improve the ability to predict in vivo effects as either a discrete (yes or no) response or a low effect level (LEL) on a continuous dose scale. Interestingly, a comparison of the in vitro assay with the lowest oral equivalent dose with the in vivo endpoint with the lowest LEL suggested that the lowest oral equivalent dose may provide a conservative estimate of the point of departure for a chemical in a dose-response assessment. Furthermore, comparing the oral equivalent doses for the in vitro assays with the in vivo dose range that resulted in adverse effects identified more coincident in vitro assays across chemicals than expected by chance, suggesting that the approach ma

  16. Effects of supplementation with higher levels of manganese and magnesium on immune function.

    PubMed

    Son, Eun-Wha; Lee, Sung-Ryul; Choi, Hye-Sook; Koo, Hyun-Jung; Huh, Jung-Eun; Kim, Mi-Hyun; Pyo, Suhkneung

    2007-06-01

    The magnesium (Mg) and manganese (Mn) were evaluated for its effectiveness as an immunomodulator in rats. The treatments were as follows: Group 1, AIN-93M diet (0.05% Mg, 0.001% Mn); Group 2, high-dose Mg (0.1% Mg, 0.001% Mn); and Group 3, high dose Mn (0.05% Mg, 0.01% Mn) (n-12/group). After 12 weeks of supplementation, rats were sacrificed to assess the effect on a range of innate responses (tumoricidal activity, oxidative burst and nitric oxide) and the mitogen-stimulated lymphoproliferative response. Immune function was significantly affected in both the high dose Mg and the Mn group. Lymphocyte proliferative responses and NK cell activity were measured in pooled spleen from each group. The mitogen response of lymphocytes to LPS in the spleen was significantly reduced in high dose Mg-treated groups, whereas the response to ConA was not affected in both high dose minerals-treated groups. The reactive oxygen species level of macrophages was decreased in both groups. These effects were more pronounced in high dose Mg-treated group. Nitric oxide production was also decreased in high dose minerals-treated group. In addition, tumoricidal activities of splenic NK cell and peritoneal macrophage in mineral exposed rats were significantly increased. Moreover, percent death of macrophage was reduced in two groups receiving high dose mineral supplements. Taken together, the present data suggest that high dose trace min erals exert a differential effect on the function of immune cells.

  17. Polymer gel dosimeters with reduced toxicity: a preliminary investigation of the NMR and optical dose response using different monomers

    NASA Astrophysics Data System (ADS)

    Senden, R. J.; DeJean, P.; McAuley, K. B.; Schreiner, L. J.

    2006-07-01

    In this work, three new polymer gel dosimeter recipes were investigated that may be more suitable for widespread applications than polyacrylamide gel dosimeters, since the extremely toxic acrylamide has been replaced with the less harmful monomers N-isopropylacrylamide (NIPAM), diacetone acrylamide and N-vinylformamide. The new gel dosimeters studied contained gelatin (5 wt%), monomer (3 wt%), N,N'-methylene-bis-acrylamide crosslinker (3 wt%) and tetrakis (hydroxymethyl) phosphonium chloride antioxidant (10 mM). The NMR response (R2) of the dosimeters was analysed for conditions of varying dose, dose rate, time post-irradiation, and temperature during irradiation and scanning. It was shown that the dose-response behaviour of the NIPAM/Bis gel dosimeter is comparable to that of normoxic polyacrylamide gel (PAGAT) in terms of high dose-sensitivity and low dependence on dose rate and irradiation temperature, within the ranges considered. The dose-response (R2) of NIPAM/Bis appears to be linear over a greater dose range than the PAGAT gel dosimeter. The effects of time post-irradiation (temporal instability) and temperature during NMR scanning on the R2 response were more significant for NIPAM/Bis dosimeters. Diacetone acrylamide and N-vinylformamide gel dosimeters possessed considerably lower dose-sensitivities. The optical dose-response, measured in terms of the attenuation coefficient for each polymer gel dosimeter, showed potential for the use of optical imaging techniques in future studies.

  18. Patient-specific dose calculations for pediatric CT of the chest, abdomen and pelvis

    PubMed Central

    Fraser, Nicholas D.; Carver, Diana E.; Pickens, David R.; Price, Ronald R.; Hernanz-Schulman, Marta; Stabin, Michael G.

    2015-01-01

    Background Organ dose is essential for accurate estimates of patient dose from CT. Objective To determine organ doses from a broad range of pediatric patients undergoing diagnostic chest–abdomen–pelvis CT and investigate how these relate to patient size. Materials and methods We used a previously validated Monte Carlo simulation model of a Philips Brilliance 64 multi-detector CT scanner (Philips Healthcare, Best, The Netherlands) to calculate organ doses for 40 pediatric patients (M:F=21:19; range 0.6–17 years). Organ volumes and positions were determined from the images using standard segmentation techniques. Non-linear regression was performed to determine the relationship between volume CT dose index (CTDIvol)-normalized organ doses and abdominopelvic diameter. We then compared results with values obtained from independent studies. Results We found that CTDIvol-normalized organ dose correlated strongly with exponentially decreasing abdominopelvic diameter (R2>0.8 for most organs). A similar relationship was determined for effective dose when normalized by dose-length product (R2=0.95). Our results agreed with previous studies within 12% using similar scan parameters (i.e. bowtie filter size, beam collimation); however results varied up to 25% when compared to studies using different bowtie filters. Conclusion Our study determined that organ doses can be estimated from measurements of patient size, namely body diameter, and CTDIvol prior to CT examination. This information provides an improved method for patient dose estimation. PMID:26142256

  19. Pharmacokinetics and pharmacodynamics of vildagliptin in healthy Chinese volunteers.

    PubMed

    Hu, Pei; Yin, Qi; Deckert, Fabienne; Jiang, Ji; Liu, Dongyang; Kjems, Lise; Dole, William P; He, Yan-Ling

    2009-01-01

    Vildagliptin is an orally effective, potent, and selective inhibitor of dipeptidyl peptidase IV (DPP-4) that improves glycemic control in patients with type 2 diabetes. This was a randomized, double-blind, placebo-controlled, time-lagged, parallel-group study in a total of 60 healthy Chinese participants. Single- and multiple-dose pharmacokinetics and pharmacodynamics, and safety and tolerability of vildagliptin were assessed following administration of 25, 50, 100, or 200 mg qd, or 50 mg bid. Vildagliptin was rapidly absorbed (tmax 1.5-2.0 hours) across the dose range of 25 to 200 mg and was quickly eliminated with a terminal elimination half-life (t1/2) of approximately 2 hours. Consistent with the short t1/2, no accumulation of vildagliptin was observed following the administration of multiple doses (accumulation factors were 1.00-1.05 across the 25- to 200-mg dose range). Vildagliptin AUC and Cmax values increased in an approximately dose-proportional fashion (dose proportionality constant beta 1.00-1.16). Administration of vildagliptin 25 to 200 mg led to rapid and near-complete (>95%) inhibition of DPP-4 activity for at least 4 hours after dosing, which was associated with increases in plasma active glucagon-like peptide-1 of up to 2- to 3-fold compared with placebo. The duration of DPP-4 inhibition increased with dose. Glucose and insulin levels were not affected by vildagliptin in healthy participants, consistent with the fact that the glucose-lowering effects of vildagliptin occur in a glucose-dependent fashion. Vildagliptin was well tolerated at the highest tested dose of 200 mg qd. Vildagliptin 25 to 200 mg qd exhibits approximately dose-proportional pharmacokinetics with no evidence of accumulation after multiple dosing in healthy Chinese participants. Vildagliptin demonstrates potent inhibition of DPP-4 activity with excellent tolerability at doses of up to and including 200 mg qd.

  20. Radiation Dose-Response Model for Locally Advanced Rectal Cancer After Preoperative Chemoradiation Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Appelt, Ane L., E-mail: ane.lindegaard.appelt@slb.regionsyddanmark.dk; University of Southern Denmark, Odense; Ploen, John

    2013-01-01

    Purpose: Preoperative chemoradiation therapy (CRT) is part of the standard treatment of locally advanced rectal cancers. Tumor regression at the time of operation is desirable, but not much is known about the relationship between radiation dose and tumor regression. In the present study we estimated radiation dose-response curves for various grades of tumor regression after preoperative CRT. Methods and Materials: A total of 222 patients, treated with consistent chemotherapy and radiation therapy techniques, were considered for the analysis. Radiation therapy consisted of a combination of external-beam radiation therapy and brachytherapy. Response at the time of operation was evaluated from themore » histopathologic specimen and graded on a 5-point scale (TRG1-5). The probability of achieving complete, major, and partial response was analyzed by ordinal logistic regression, and the effect of including clinical parameters in the model was examined. The radiation dose-response relationship for a specific grade of histopathologic tumor regression was parameterized in terms of the dose required for 50% response, D{sub 50,i}, and the normalized dose-response gradient, {gamma}{sub 50,i}. Results: A highly significant dose-response relationship was found (P=.002). For complete response (TRG1), the dose-response parameters were D{sub 50,TRG1} = 92.0 Gy (95% confidence interval [CI] 79.3-144.9 Gy), {gamma}{sub 50,TRG1} = 0.982 (CI 0.533-1.429), and for major response (TRG1-2) D{sub 50,TRG1} and {sub 2} = 72.1 Gy (CI 65.3-94.0 Gy), {gamma}{sub 50,TRG1} and {sub 2} = 0.770 (CI 0.338-1.201). Tumor size and N category both had a significant effect on the dose-response relationships. Conclusions: This study demonstrated a significant dose-response relationship for tumor regression after preoperative CRT for locally advanced rectal cancer for tumor dose levels in the range of 50.4-70 Gy, which is higher than the dose range usually considered.« less

  1. OCCUPATIONAL RADIATION DOSES TO OPERATORS PERFORMING FLUOROSCOPICALLY-GUIDED PROCEDURES

    PubMed Central

    Kim, Kwang Pyo; Miller, Donald L.; de Gonzalez, Amy Berrington; Balter, Stephen; Kleinerman, Ruth A.; Ostroumova, Evgenia; Simon, Steven L.; Linet, Martha S.

    2012-01-01

    In the past 30 years, the numbers and types of fluoroscopically-guided (FG) procedures have increased dramatically. The objective of the present study is to provide estimated radiation doses to physician specialists, other than cardiologists, who perform FG procedures. We searched Medline to identify English-language journal articles reporting radiation exposures to these physicians. We then identified several primarily therapeutic FG procedures that met specific criteria: well-defined procedures for which there were at least five published reports of estimated radiation doses to the operator, procedures performed frequently in current medical practice, and inclusion of physicians from multiple medical specialties. These procedures were percutaneous nephrolithotomy (PCNL), vertebroplasty, orthopedic extremity nailing for treatment of fractures, biliary tract procedures, transjugular intrahepatic portosystemic shunt creation (TIPS), head/neck endovascular therapeutic procedures, and endoscopic retrograde cholangiopancreatography (ERCP). We abstracted radiation doses and other associated data, and estimated effective dose to operators. Operators received estimated doses per patient procedure equivalent to doses received by interventional cardiologists. The estimated effective dose per case ranged from 1.7 – 56μSv for PCNL, 0.1 – 101 μSv for vertebroplasty, 2.5 – 88μSv for orthopedic extremity nailing, 2.0 – 46μSv for biliary tract procedures, 2.5 – 74μSv for TIPS, 1.8 – 53μSv for head/neck endovascular therapeutic procedures, and 0.2 – 49μSv for ERCP. Overall, mean operator radiation dose per case measured over personal protective devices at different anatomic sites on the head and body ranged from 19 – 800 (median = 113) μSv at eye level, 6 – 1180 (median = 75)μSv at the neck, and 2 – 1600 (median = 302) μSv at the trunk. Operators’ hands often received greater doses than the eyes, neck or trunk. Large variations in operator doses suggest that optimizing procedure protocols and proper use of protective devices and shields might reduce occupational radiation dose substantially. PMID:22647920

  2. Biological and dosimetric characterisation of spatially fractionated proton minibeams

    NASA Astrophysics Data System (ADS)

    Meyer, Juergen; Stewart, Robert D.; Smith, Daniel; Eagle, James; Lee, Eunsin; Cao, Ning; Ford, Eric; Hashemian, Reza; Schuemann, Jan; Saini, Jatinder; Marsh, Steve; Emery, Robert; Dorman, Eric; Schwartz, Jeff; Sandison, George

    2017-12-01

    The biological effectiveness of proton beams varies with depth, spot size and lateral distance from the beam central axis. The aim of this work is to incorporate proton relative biological effectiveness (RBE) and equivalent uniform dose (EUD) considerations into comparisons of broad beam and highly modulated proton minibeams. A Monte Carlo model of a small animal proton beamline is presented. Dose and variable RBE is calculated on a per-voxel basis for a range of energies (30-109 MeV). For an open beam, the RBE values at the beam entrance ranged from 1.02-1.04, at the Bragg peak (BP) from 1.3 to 1.6, and at the distal end of the BP from 1.4 to 2.0. For a 50 MeV proton beam, a minibeam collimator designed to produce uniform dose at the depth of the BP peak, had minimal impact on the open beam RBE values at depth. RBE changes were observed near the surface when the collimator was placed flush with the irradiated object, due to a higher neutron contribution derived from proton interactions with the collimator. For proton minibeams, the relative mean RBE weighted entrance dose (RWD) was ~25% lower than the physical mean dose. A strong dependency of the EUD with fraction size was observed. For 20 Gy fractions, the EUD varied widely depending on the radiosensitivity of the cells. For radiosensitive cells, the difference was up to ~50% in mean dose and ~40% in mean RWD and the EUD trended towards the valley dose rather than the mean dose. For comparative studies of uniform dose with spatially fractionated proton minibeams, EUD derived from a per-voxel RWD distribution is recommended for biological assessments of reproductive cell survival and related endpoints.

  3. Biological and dosimetric characterisation of spatially fractionated proton minibeams.

    PubMed

    Meyer, Juergen; Stewart, Robert D; Smith, Daniel; Eagle, James; Lee, Eunsin; Cao, Ning; Ford, Eric; Hashemian, Reza; Schuemann, Jan; Saini, Jatinder; Marsh, Steve; Emery, Robert; Dorman, Eric; Schwartz, Jeff; Sandison, George

    2017-11-21

    The biological effectiveness of proton beams varies with depth, spot size and lateral distance from the beam central axis. The aim of this work is to incorporate proton relative biological effectiveness (RBE) and equivalent uniform dose (EUD) considerations into comparisons of broad beam and highly modulated proton minibeams. A Monte Carlo model of a small animal proton beamline is presented. Dose and variable RBE is calculated on a per-voxel basis for a range of energies (30-109 MeV). For an open beam, the RBE values at the beam entrance ranged from 1.02-1.04, at the Bragg peak (BP) from 1.3 to 1.6, and at the distal end of the BP from 1.4 to 2.0. For a 50 MeV proton beam, a minibeam collimator designed to produce uniform dose at the depth of the BP peak, had minimal impact on the open beam RBE values at depth. RBE changes were observed near the surface when the collimator was placed flush with the irradiated object, due to a higher neutron contribution derived from proton interactions with the collimator. For proton minibeams, the relative mean RBE weighted entrance dose (RWD) was ~25% lower than the physical mean dose. A strong dependency of the EUD with fraction size was observed. For 20 Gy fractions, the EUD varied widely depending on the radiosensitivity of the cells. For radiosensitive cells, the difference was up to ~50% in mean dose and ~40% in mean RWD and the EUD trended towards the valley dose rather than the mean dose. For comparative studies of uniform dose with spatially fractionated proton minibeams, EUD derived from a per-voxel RWD distribution is recommended for biological assessments of reproductive cell survival and related endpoints.

  4. The contribution of interventional cardiology procedures to the population radiation dose in a ‘health-care level I’ representative region

    PubMed Central

    Peruzzo Cornetto, Andrea; Aimonetto, Stefania; Pisano, Francesco; Giudice, Marcello; Sicuro, Marco; Meloni, Teodoro; Tofani, Santi

    2016-01-01

    This study evaluates per-procedure, collective and per capita effective dose to the population by interventional cardiology (IC) procedures performed during 2002–11 at the main hospital of Aosta Valley Region that can be considered as representative of the health-care level I countries, as defined by the UNSCEAR, based on its socio-demographic characteristics. IC procedures investigated were often multiple procedures in patients older than 60 y. The median extreme dose-area product values of 300 and 22 908 cGycm2 were found for standard pacemaker implantation and coronary angioplasty, respectively, while the relative mean per-procedure effective dose ranged from 0.7 to 47 mSv. A 3-fold increase in frequency has been observed together with a correlated increase in the delivered per capita dose (0.05–0.27 mSv y−1) and the collective dose (5.8–35 man Sv y−1). Doses increased particularly from 2008 onwards mainly because of the introduction of coronary angioplasty procedures in the authors’ institution. IC practice contributed remarkably in terms of effective dose to the population, delivering ∼10 % of the total dose by medical ionising radiation examination categories. PMID:26012484

  5. SU-E-T-374: Evaluation and Verification of Dose Calculation Accuracy with Different Dose Grid Sizes for Intracranial Stereotactic Radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Han, C; Schultheiss, T

    Purpose: In this study, we aim to evaluate the effect of dose grid size on the accuracy of calculated dose for small lesions in intracranial stereotactic radiosurgery (SRS), and to verify dose calculation accuracy with radiochromic film dosimetry. Methods: 15 intracranial lesions from previous SRS patients were retrospectively selected for this study. The planning target volume (PTV) ranged from 0.17 to 2.3 cm{sup 3}. A commercial treatment planning system was used to generate SRS plans using the volumetric modulated arc therapy (VMAT) technique using two arc fields. Two convolution-superposition-based dose calculation algorithms (Anisotropic Analytical Algorithm and Acuros XB algorithm) weremore » used to calculate volume dose distribution with dose grid size ranging from 1 mm to 3 mm with 0.5 mm step size. First, while the plan monitor units (MU) were kept constant, PTV dose variations were analyzed. Second, with 95% of the PTV covered by the prescription dose, variations of the plan MUs as a function of dose grid size were analyzed. Radiochomic films were used to compare the delivered dose and profile with the calculated dose distribution with different dose grid sizes. Results: The dose to the PTV, in terms of the mean dose, maximum, and minimum dose, showed steady decrease with increasing dose grid size using both algorithms. With 95% of the PTV covered by the prescription dose, the total MU increased with increasing dose grid size in most of the plans. Radiochromic film measurements showed better agreement with dose distributions calculated with 1-mm dose grid size. Conclusion: Dose grid size has significant impact on calculated dose distribution in intracranial SRS treatment planning with small target volumes. Using the default dose grid size could lead to under-estimation of delivered dose. A small dose grid size should be used to ensure calculation accuracy and agreement with QA measurements.« less

  6. Estimated radiation exposure of German commercial airline cabin crew in the years 1960-2003 modeled using dose registry data for 2004-2015.

    PubMed

    Wollschläger, Daniel; Hammer, Gaël Paul; Schafft, Thomas; Dreger, Steffen; Blettner, Maria; Zeeb, Hajo

    2018-05-01

    Exposure to ionizing radiation of cosmic origin is an occupational risk factor in commercial aircrew. In a historic cohort of 26,774 German aircrew, radiation exposure was previously estimated only for cockpit crew using a job-exposure matrix (JEM). Here, a new method for retrospectively estimating cabin crew dose is developed. The German Federal Radiation Registry (SSR) documents individual monthly effective doses for all aircrew. SSR-provided doses on 12,941 aircrew from 2004 to 2015 were used to model cabin crew dose as a function of age, sex, job category, solar activity, and male pilots' dose; the mean annual effective dose was 2.25 mSv (range 0.01-6.39 mSv). In addition to an inverse association with solar activity, exposure followed age- and sex-dependent patterns related to individual career development and life phases. JEM-derived annual cockpit crew doses agreed with SSR-provided doses for 2004 (correlation 0.90, 0.40 mSv root mean squared error), while the estimated average annual effective dose for cabin crew had a prediction error of 0.16 mSv, equaling 7.2% of average annual dose. Past average annual cabin crew dose can be modeled by exploiting systematic external influences as well as individual behavioral determinants of radiation exposure, thereby enabling future dose-response analyses of the full aircrew cohort including measurement error information.

  7. Effect of hypothalamic neuropeptides on corticotrophin release from quarters of rat anterior pituitary gland in vitro.

    PubMed

    Nicholson, S A; Adrian, T E; Gillham, B; Jones, M T; Bloom, S R

    1984-02-01

    The effect of six hypothalamic peptides on the basal release of ACTH and that induced by arginine vasopressin (AVP) or by ovine corticotrophin releasing factor (oCRF) from fragments of the rat anterior pituitary gland incubated in vitro was investigated. Dose-response curves to AVP and to oCRF were obtained, and the response to a low dose of oCRF was potentiated by a low dose of AVP. Basal release of ACTH was not affected by any of the peptides in concentrations in the range 10(-12) to 10(-6) mol/l, and only substance P (SP) and somatostatin (SRIF) inhibited significantly the response to oCRF in a dose-related manner. The responses to a range of doses of oCRF or AVP were reduced by 10(-8) and 10(-6) mol SP or SRIF/l, and to a greater extent by the higher dose. Except in the case of 10(-6) mol SRIF/l on the response to AVP, the response was not further diminished by preincubation of the tissue with the peptide before the stimulating agent was added. The inhibition of the responses to AVP or oCRF by 10(-9) mol SP/l was not potentiated by its combination with either 5 X 10(-10) or 10(-8) mol SRIF/l; the inhibitory effects were merely additive. The results suggest that although SRIF and SP are able to modulate the release of ACTH from the anterior pituitary gland, they do so only at a high concentration.(ABSTRACT TRUNCATED AT 250 WORDS)

  8. Evaluation and optimisation of current milrinone prescribing for the treatment and prevention of low cardiac output syndrome in paediatric patients after open heart surgery using a physiology-based pharmacokinetic drug-disease model.

    PubMed

    Vogt, Winnie

    2014-01-01

    Milrinone is the drug of choice for the treatment and prevention of low cardiac output syndrome (LCOS) in paediatric patients after open heart surgery across Europe. Discrepancies, however, among prescribing guidance, clinical studies and practice pattern require clarification to ensure safe and effective prescribing. However, the clearance prediction equations derived from classical pharmacokinetic modelling provide limited support as they have recently failed a clinical practice evaluation. Therefore, the objective of this study was to evaluate current milrinone dosing using physiology-based pharmacokinetic (PBPK) modelling and simulation to complement the existing pharmacokinetic knowledge and propose optimised dosing regimens as a basis for improving the standard of care for paediatric patients. A PBPK drug-disease model using a population approach was developed in three steps from healthy young adults to adult patients and paediatric patients with and without LCOS after open heart surgery. Pre- and postoperative organ function values from adult and paediatric patients were collected from literature and integrated into a disease model as factorial changes from the reference values in healthy adults aged 20-40 years. The disease model was combined with the PBPK drug model and evaluated against existing pharmacokinetic data. Model robustness was assessed by parametric sensitivity analysis. In the next step, virtual patient populations were created, each with 1,000 subjects reflecting the average adult and paediatric patient characteristics with regard to age, sex, bodyweight and height. They were integrated into the PBPK drug-disease model to evaluate the effectiveness of current milrinone dosing in achieving the therapeutic target range of 100-300 ng/mL milrinone in plasma. Optimised dosing regimens were subsequently developed. The pharmacokinetics of milrinone in healthy young adults as well as adult and paediatric patients were accurately described with an average fold error of 1.1 ± 0.1 (mean ± standard deviation) and mean relative deviation of 1.5 ± 0.3 as measures of bias and precision, respectively. Normalised maximum sensitivity coefficients for model input parameters ranged from -0.84 to 0.71, which indicated model robustness. The evaluation of milrinone dosing across different paediatric age groups showed a non-linear age dependence of total plasma clearance and exposure differences of a factor 1.4 between patients with and without LCOS for a fixed dosing regimen. None of the currently used dosing regimens for milrinone achieved the therapeutic target range across all paediatric age groups and adult patients, so optimised dosing regimens were developed that considered the age-dependent and pathophysiological differences. The PBPK drug-disease model for milrinone in paediatric patients with and without LCOS after open heart surgery highlights that age, disease and surgery differently impact the pharmacokinetics of milrinone, and that current milrinone dosing for LCOS is suboptimal to maintain the therapeutic target range across the entire paediatric age range. Thus, optimised dosing strategies are proposed to ensure safe and effective prescribing.

  9. Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification

    PubMed Central

    Suriyapee, S; Pitaxtarnin, N; Oonsiri, S; Jumpangern, C; Israngkul Na Ayuthaya, I

    2008-01-01

    Purpose: To investigate the optimal sensitometric curves of extended dose range (EDR2) radiographic film in terms of depth, field size, dose range and processing conditions for dynamic intensity modulated radiation therapy (IMRT) dosimetry verification with 6 MV X-ray beams. Materials and methods: A Varian Clinac 23 EX linear accelerator with 6 MV X-ray beam was used to study the response of Kodak EDR2 film. Measurements were performed at depths of 5, 10 and 15 cm in MedTec virtual water phantom and with field sizes of 2x2, 3x3, 10x10 and 15x15 cm2. Doses ranging from 20 to 450 cGy were used. The film was developed with the Kodak RP X-OMAT Model M6B automatic film processor. Film response was measured with the Vidar model VXR-16 scanner. Sensitometric curves were applied to the dose profiles measured with film at 5 cm in the virtual water phantom with field sizes of 2x2 and 10x10 cm2 and compared with ion chamber data. Scanditronix/Wellhofer OmniProTM IMRT software was used for the evaluation of the IMRT plan calculated by Eclipse treatment planning. Results: Investigation of the reproducibility and accuracy of the film responses, which depend mainly on the film processor, was carried out by irradiating one film nine times with doses of 20 to 450 cGy. A maximum standard deviation of 4.9% was found which decreased to 1.9% for doses between 20 and 200 cGy. The sensitometric curves for various field sizes at fixed depth showed a maximum difference of 4.2% between 2x2 and 15x15 cm2 at 5 cm depth with a dose of 450 cGy. The shallow depth tended to show a greater effect of field size responses than the deeper depths. The sensitometric curves for various depths at fixed field size showed slightly different film responses; the difference due to depth was within 1.8% for all field sizes studied. Both field size and depth effect were reduced when the doses were lower than 450 cGy. The difference was within 2.5% in the dose range from 20 to 300 cGy for all field sizes and depths studied. Dose profiles measured with EDR2 film were consistent with those measured with an ion chamber. The optimal sensitometric curve was acquired by irradiating film at a depth of 5 cm with doses ranging from 20 to 450 cGy with a 3×3 cm2 multileaf collimator. The optimal sensitometric curve allowed accurate determination of the absolute dose distribution. In almost 200 cases of dynamic IMRT plan verification with EDR2 film, the difference between measured and calculated dose was generally less than 3% and with 3 mm distance to agreement when using gamma value verification. Conclusion: EDR2 film can be used for accurate verification of composite isodose distributions of dynamic IMRT when the optimal sensitometric curve has been established. PMID:21614315

  10. Optimal sensitometric curves of Kodak EDR2 film for dynamic intensity modulated radiation therapy verification.

    PubMed

    Suriyapee, S; Pitaxtarnin, N; Oonsiri, S; Jumpangern, C; Israngkul Na Ayuthaya, I

    2008-01-01

    To investigate the optimal sensitometric curves of extended dose range (EDR2) radiographic film in terms of depth, field size, dose range and processing conditions for dynamic intensity modulated radiation therapy (IMRT) dosimetry verification with 6 MV X-ray beams. A Varian Clinac 23 EX linear accelerator with 6 MV X-ray beam was used to study the response of Kodak EDR2 film. Measurements were performed at depths of 5, 10 and 15 cm in MedTec virtual water phantom and with field sizes of 2x2, 3x3, 10x10 and 15x15 cm(2). Doses ranging from 20 to 450 cGy were used. The film was developed with the Kodak RP X-OMAT Model M6B automatic film processor. Film response was measured with the Vidar model VXR-16 scanner. Sensitometric curves were applied to the dose profiles measured with film at 5 cm in the virtual water phantom with field sizes of 2x2 and 10x10 cm(2) and compared with ion chamber data. Scanditronix/Wellhofer OmniPro(TM) IMRT software was used for the evaluation of the IMRT plan calculated by Eclipse treatment planning. Investigation of the reproducibility and accuracy of the film responses, which depend mainly on the film processor, was carried out by irradiating one film nine times with doses of 20 to 450 cGy. A maximum standard deviation of 4.9% was found which decreased to 1.9% for doses between 20 and 200 cGy. The sensitometric curves for various field sizes at fixed depth showed a maximum difference of 4.2% between 2x2 and 15x15 cm(2) at 5 cm depth with a dose of 450 cGy. The shallow depth tended to show a greater effect of field size responses than the deeper depths. The sensitometric curves for various depths at fixed field size showed slightly different film responses; the difference due to depth was within 1.8% for all field sizes studied. Both field size and depth effect were reduced when the doses were lower than 450 cGy. The difference was within 2.5% in the dose range from 20 to 300 cGy for all field sizes and depths studied. Dose profiles measured with EDR2 film were consistent with those measured with an ion chamber. The optimal sensitometric curve was acquired by irradiating film at a depth of 5 cm with doses ranging from 20 to 450 cGy with a 3×3 cm(2) multileaf collimator. The optimal sensitometric curve allowed accurate determination of the absolute dose distribution. In almost 200 cases of dynamic IMRT plan verification with EDR2 film, the difference between measured and calculated dose was generally less than 3% and with 3 mm distance to agreement when using gamma value verification. EDR2 film can be used for accurate verification of composite isodose distributions of dynamic IMRT when the optimal sensitometric curve has been established.

  11. Multi-axis dose accumulation of noninvasive image-guided breast brachytherapy through biomechanical modeling of tissue deformation using the finite element method

    PubMed Central

    Ghadyani, Hamid R.; Bastien, Adam D.; Lutz, Nicholas N.; Hepel, Jaroslaw T.

    2015-01-01

    Purpose Noninvasive image-guided breast brachytherapy delivers conformal HDR 192Ir brachytherapy treatments with the breast compressed, and treated in the cranial-caudal and medial-lateral directions. This technique subjects breast tissue to extreme deformations not observed for other disease sites. Given that, commercially-available software for deformable image registration cannot accurately co-register image sets obtained in these two states, a finite element analysis based on a biomechanical model was developed to deform dose distributions for each compression circumstance for dose summation. Material and methods The model assumed the breast was under planar stress with values of 30 kPa for Young's modulus and 0.3 for Poisson's ratio. Dose distributions from round and skin-dose optimized applicators in cranial-caudal and medial-lateral compressions were deformed using 0.1 cm planar resolution. Dose distributions, skin doses, and dose-volume histograms were generated. Results were examined as a function of breast thickness, applicator size, target size, and offset distance from the center. Results Over the range of examined thicknesses, target size increased several millimeters as compression thickness decreased. This trend increased with increasing offset distances. Applicator size minimally affected target coverage, until applicator size was less than the compressed target size. In all cases, with an applicator larger or equal to the compressed target size, > 90% of the target covered by > 90% of the prescription dose. In all cases, dose coverage became less uniform as offset distance increased and average dose increased. This effect was more pronounced for smaller target–applicator combinations. Conclusions The model exhibited skin dose trends that matched MC-generated benchmarking results within 2% and clinical observations over a similar range of breast thicknesses and target sizes. The model provided quantitative insight on dosimetric treatment variables over a range of clinical circumstances. These findings highlight the need for careful target localization and accurate identification of compression thickness and target offset. PMID:25829938

  12. SU-E-T-577: Obliquity Factor and Surface Dose in Proton Beam Therapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Das, I; Andersen, A; Coutinho, L

    2015-06-15

    Purpose: The advantage of lower skin dose in proton beam may be diminished creating radiation related sequalae usually seen with photon and electron beams. This study evaluates the surface dose as a complex function of beam parameters but more importantly the effect of beam angle. Methods: Surface dose in proton beam depends on the beam energy, source to surface distance, the air gap between snout and surface, field size, material thickness in front of surface, atomic number of the medium, beam angle and type of nozzle (ie double scattering, (DS), uniform scanning (US) or pencil beam scanning (PBS). Obliquity factormore » (OF) is defined as ratio of surface dose in 0° to beam angle Θ. Measurements were made in water phantom at various beam angles using very small microdiamond that has shown favorable beam characteristics for high, medium and low proton energy. Depth dose measurements were performed in the central axis of the beam in each respective gantry angle. Results: It is observed that surface dose is energy dependent but more predominantly on the SOBP. It is found that as SSD increases, surface dose decreases. In general, SSD, and air gap has limited impact in clinical proton range. High energy has higher surface dose and so the beam angle. The OF rises with beam angle. Compared to OF of 1.0 at 0° beam angle, the value is 1.5, 1.6, 1,7 for small, medium and large range respectively for 60 degree angle. Conclusion: It is advised that just like range and SOBP, surface dose should be clearly understood and a method to reduce the surface dose should be employed. Obliquity factor is a critical parameter that should be accounted in proton beam therapy and a perpendicular beam should be used to reduce surface dose.« less

  13. Exposure to Non-Therapeutic INR in a High Risk Cardiovascular Patient: Potential Hazard Reduction with Genotype-guided Warfarin (Coumadin®) Dosing

    PubMed Central

    Rodríguez-Vélez, Rosángela; Ortiz-Rivera, Oscar J.; Bower, Bruce; Gorowski, Krystyna; Windemuth, Andreas; Villagra, David; Kocherla, Mohan; Seip, Richard L; D'Agostino, Darrin; Vergara, Cunegundo; Ruaño, Gualberto; Duconge, Jorge

    2013-01-01

    A case to illustrate the utility of genetic screening in warfarin (Coumadin®) management is reported. A 45 year-old woman of Puerto Rican ancestry was admitted to the emergency room twice within one month with chest pain. She was diagnosed with congestive heart failure, which was stabilized both times. At her second release, warfarin therapy was initiated at 5 mg/day to prevent thrombus formation and was lowered to 3.75 mg/day at day 7 by her primary physician. International Normalized Ratio (INR) test results in the follow-up period at days 1, 7, and 10 of warfarin therapy were 4.5, 6.5, and 7.3, respectively—far in excess of the therapeutic range, despite the lower dosage in effect from day 7 onward. the patient achieved target INR over the next 43 days after downward adjustment of the dose to a dose of 1.5 mg/day by trial and error. DNA-typing specific for the CYP2C9*2, *3, *4, *5, *6 alleles and seven variants in the VKORC1 gene, including the VKORC1-1639 G>A polymorphism, revealed the presence of combinatorial CYP2C9*2/*3 and VKORC1-1639 G/A genotypes in this patient. Entering the patient's demographic and genotype status data into independent algorithms available in the public domain to predict effective warfarin dose yielded predicted doses which ranged from 1.5 to 1.8 mg/day. Notably, the prediction of 1.5 mg/day, which was generated by the online resource www.warfarindosing.org, coincided with the patient's actual effective warfarin dose. We conclude that the rapid rise in INR observed upon the initiation of warfarin therapy and the final effective warfarin dose of 1.5 mg/day, are attributable in some part to the presence of two minor alleles in CYP2C9, which together significantly reduce warfarin metabolism. Warfarin genotyping can therefore inform the clinician of the predicted effective warfarin dose. the results highlight the potential for warfarin genetic testing to improve patient care. PMID:21261182

  14. Effects of head-only or whole-body exposure to very low doses of 4HE (1000 MeV/n) particles

    USDA-ARS?s Scientific Manuscript database

    INTRODUCTION On exploratory class missions, astronauts will be exposed to a range of heavy particles which vary in linear energy transfer (LET). Previous research has shown a direct relationship between particle LET and cognitive performance such that, as particle LET decreases the dose needed to af...

  15. Plasma Methylphenidate Levels in Youths With Attention Deficit Hyperactivity Disorder Treated With OROS Formulation.

    PubMed

    Yorbik, Ozgur; Mutlu, Caner; Ozilhan, Selma; Eryilmaz, Gul; Isiten, Nuket; Alparslan, Serdar; Saglam, Esra

    2015-06-01

    There are limited studies investigating the relationship between oral release osmotic system-methylphenidate (OROS-MPH) doses and plasma methylphenidate (MPH) concentrations in children and adolescents. The aim of this study was to investigate the relationship between the doses of OROS-MPH and the plasma levels of the drug. We also examined the effects of the other drugs including aripiprazole, risperidone, fluoxetine, and sertraline on the levels of the MPH in the plasma. The files of 100 attention deficit hyperactivity disorder (ADHD) subjects (76 male, 24 female) who were diagnosed as ADHD according to the Diagnostic and Statistical Manual of Mental Disorders-Fourth Edition criteria, were screened. The ages of subjects were between 6 and 18 years (mean = 11.5 ± 3.8 years). Plasma MPH levels were determined by high-performance liquid chromatography-tandem mass spectrometry assay. Daily mean OROS-MPH dose used in ADHD children was 0.7 ± 0.2 mg/kg (range: 0.3-1.3 mg/kg). The mean plasma OROS-MPH was 11.6 ± 7.3 ng/mL (range: 0.5-43.4 ng/mL). There was no group difference in the mean plasma MPH and dose-related MPH levels between the groups that used any additional drug including aripiprazole (n = 25), risperidone (n = 10), fluoxetine (n = 16), sertraline (n = 10), and did not use these drugs (P > 0.05). There was a positive correlation between the OROS-MPH doses (mg/kg) and the blood MPH levels (Pearson correlation = 0.40; P < 0.001). The plasma levels of MPH were found to be less than 13 ng/mL in 65% of the subjects. Our findings point to the fact that plasma levels of MPH show a wide range of changes at similar doses, correlate positively with the doses and, as expected, are not affected by using risperidone, sertraline, fluoxetine, and aripiprazole. Therapeutic drug monitoring may help to optimize MPH dose in patients not responding to treatment or in those experiencing serious side effects, but not in routine clinical practice. The presence of intermediate dose formulations such as 45-mg tablets for OROS-MPH may contribute to the optimization.

  16. Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses.

    PubMed

    Huda, Walter; Lieberman, Kristin A; Chang, Jack; Roskopf, Marsha L

    2004-03-01

    We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18 x 7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186+/-8 mm and 147+/-8 mm, respectively, with an average HU value of 209+/-40. An infant head was found to be equivalent to a water cylinder with a radius of approximately 60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is approximately 20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors.

  17. Radon-222 in groundwater and effective dose due to ingestion and inhalation in the city of Ibadan, Nigeria.

    PubMed

    Ademola, Janet Ayobami; Oyeleke, Oyebode Akanni

    2017-03-20

    Radon concentration in groundwater collected from the eleven Local Government Areas (LGAs) of Ibadan, Nigeria, was analyzed. Annual effective doses due to ingestion and inhalation of radon from the consumption of the water were determined. The arithmetic means (AMs) of radon concentration for the 11 LGAs varied from 2.18 to 76.75 Bq l -1 with a standard deviation of 1.57 and 70.64 Bq l -1 , respectively. The geometric means (GMs) varied from 1.67 to 49.47 Bq l -1 with geometric standard deviation of 2.22 and 3.04, respectively. About 58% of the 84 water samples examined had a higher concentration of radon than the 11.1 Bq l -1 recommended by United States Environmental Protection Agency (USEPA); the AMs of six LGAs and GMs of three LGAs were higher than the recommended value. However the AMs and GMs of all the LGAs with about 93% of the water sampled were lower than the 100 Bq l -1 recommended by the World Health Organization and EURATOM drinking water directive. The concentration of radon varied with the geological formation of the area. The AMs of the annual effective dose due to ingestion of radon in water ranged from 0.036 to 1.261 mSv y -1 , 0.071 to 2.521 mSv y -1 and 0.042 to 1.471 mSv y -1 for adult, child and infant, respectively and the GMs in the range of 0.026 to 0.813, 0.055 to 1.625 and 0.032 to 0.948 mSv y -1 , respectively. The AMs of 10 LGAs and GMs of 7 LGAs were higher than the recommended reference dose level of 0.1 mSv y -1 from the consumption of water for the duration of one year for all the three categories of people. The AMs and GMs of the annual effective dose due to inhalation of radon in drinking water ranged from 0.533 to 18.82 μSv y -1 and 0.411 to 12.13 μSv y -1 , respectively, contributing less to the overall dose.

  18. Betahistine exerts a dose-dependent effect on cochlear stria vascularis blood flow in guinea pigs in vivo.

    PubMed

    Ihler, Fritz; Bertlich, Mattis; Sharaf, Kariem; Strieth, Sebastian; Strupp, Michael; Canis, Martin

    2012-01-01

    Betahistine is a histamine H(1)-receptor agonist and H(3)-receptor antagonist that is administered to treat Menière's disease. Despite widespread use, its pharmacological mode of action has not been entirely elucidated. This study investigated the effect of betahistine on guinea pigs at dosages corresponding to clinically used doses for cochlear microcirculation. Thirty healthy Dunkin-Hartley guinea pigs were randomly assigned to five groups to receive betahistine dihydrochloride in a dose of 1,000 mg/kg b. w. (milligram per kilogram body weight), 0.100 mg/kg b. w., 0.010 mg/kg b. w., 0.001 mg/kg b. w. in NaCl 0.9% or NaCl 0.9% alone as placebo. Cochlear blood flow and mean arterial pressure were continuously monitored by intravital fluorescence microscopy and invasive blood pressure measurements 3 minutes before and 15 minutes after administration of betahistine. When betahistine was administered in a dose of 1.000 mg/kg b. w. cochlear blood flow was increased to a peak value of 1.340 arbitrary units (SD: 0.246; range: 0.933-1.546 arb. units) compared to baseline (p<0.05; Two Way Repeated Measures ANOVA/Bonferroni t-test). The lowest dosage of 0.001 mg/kg b. w. betahistine or NaCl 0.9% had the same effect as placebo. Nonlinear regression revealed that there was a sigmoid correlation between increase in blood flow and dosages. Betahistine has a dose-dependent effect on the increase of blood flow in cochlear capillaries. The effects of the dosage range of betahistine on cochlear microcirculation corresponded well to clinically used single dosages to treat Menière's disease. Our data suggest that the improved effects of higher doses of betahistine in the treatment of Menière's disease might be due to a corresponding increase of cochlear blood flow.

  19. Betahistine Exerts a Dose-Dependent Effect on Cochlear Stria Vascularis Blood Flow in Guinea Pigs In Vivo

    PubMed Central

    Ihler, Fritz; Bertlich, Mattis; Sharaf, Kariem; Strieth, Sebastian

    2012-01-01

    Objective Betahistine is a histamine H1-receptor agonist and H3-receptor antagonist that is administered to treat Menière’s disease. Despite widespread use, its pharmacological mode of action has not been entirely elucidated. This study investigated the effect of betahistine on guinea pigs at dosages corresponding to clinically used doses for cochlear microcirculation. Methods Thirty healthy Dunkin-Hartley guinea pigs were randomly assigned to five groups to receive betahistine dihydrochloride in a dose of 1,000 mg/kg b. w. (milligram per kilogram body weight), 0.100 mg/kg b. w., 0.010 mg/kg b. w., 0.001 mg/kg b. w. in NaCl 0.9% or NaCl 0.9% alone as placebo. Cochlear blood flow and mean arterial pressure were continuously monitored by intravital fluorescence microscopy and invasive blood pressure measurements 3 minutes before and 15 minutes after administration of betahistine. Results When betahistine was administered in a dose of 1.000 mg/kg b. w. cochlear blood flow was increased to a peak value of 1.340 arbitrary units (SD: 0.246; range: 0.933–1.546 arb. units) compared to baseline (p<0.05; Two Way Repeated Measures ANOVA/Bonferroni t-test). The lowest dosage of 0.001 mg/kg b. w. betahistine or NaCl 0.9% had the same effect as placebo. Nonlinear regression revealed that there was a sigmoid correlation between increase in blood flow and dosages. Conclusions Betahistine has a dose-dependent effect on the increase of blood flow in cochlear capillaries. The effects of the dosage range of betahistine on cochlear microcirculation corresponded well to clinically used single dosages to treat Menière’s disease. Our data suggest that the improved effects of higher doses of betahistine in the treatment of Menière’s disease might be due to a corresponding increase of cochlear blood flow. PMID:22745706

  20. Low dose evaluation of the antiandrogen flutamide following a Mode of Action approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sarrabay, A.; UniverSud, INSERM, UMR-996 “Inflammation, Chemokines and Immunopathology”, Châtenay-Malabry; Bayer SAS, 16, rue Jean Marie Leclair, 69009 Lyon

    ABSTRACT: The dose–response characterization of endocrine mediated toxicity is an on-going debate which is controversial when exploring the nature of the dose–response curve and the effect at the low-end of the curve. To contribute to this debate we have assessed the effects of a wide range of dose levels of the antiandrogen flutamide (FLU) on 7-week male Wistar rats. FLU was administered by oral gavage at doses of 0, 0.001, 0.01, 0.1, 1 and 10 mg/kg/day for 28 days. To evaluate the reproducibility, the study was performed 3 times. The molecular initiating event (MIE; AR antagonism), the key events (LHmore » increase, Leydig cell proliferation and hyperplasia increases) and associated events involved in the mode of action (MOA) of FLU induced testicular toxicity were characterized to address the dose response concordance. Results showed no effects at low doses (< 0.1 mg/kg/day) for the different key events studied. The histopathological changes (Leydig cell hyperplasia) observed at 1 and 10 mg/kg/day were associated with an increase in steroidogenesis gene expression in the testis from 1 mg/kg/day, as well as an increase in testosterone blood level at 10 mg/kg/day. Each key event dose–response was in good concordance with the MOA of FLU on the testis. From the available results, only monotonic dose–response curves were observed for the MIE, the key events, associated events and in effects observed in other sex related tissues. All the results, so far, show that the reference endocrine disruptor FLU induces threshold effects in a standard 28-day toxicity study on adult male rats. - Highlights: • Dose–response characterization of endocrine mediated toxicity is an on-going debate. • A wide range of dose levels of flutamide was evaluated on young adult male rats. • Flutamide induces threshold effects using on standard and molecular tools.« less

  1. Understanding the cognitive impact of the contraceptive estrogen Ethinyl Estradiol: tonic and cyclic administration impairs memory, and performance correlates with basal forebrain cholinergic system integrity.

    PubMed

    Mennenga, Sarah E; Gerson, Julia E; Koebele, Stephanie V; Kingston, Melissa L; Tsang, Candy W S; Engler-Chiurazzi, Elizabeth B; Baxter, Leslie C; Bimonte-Nelson, Heather A

    2015-04-01

    Ethinyl Estradiol (EE), a synthetic, orally bio-available estrogen, is the most commonly prescribed form of estrogen in oral contraceptives, and is found in at least 30 different contraceptive formulations currently prescribed to women as well as hormone therapies prescribed to menopausal women. Thus, EE is prescribed clinically to women at ages ranging from puberty to reproductive senescence. Here, in two separate studies, the cognitive effects of cyclic or tonic EE administration following ovariectomy (Ovx) were evaluated in young female rats. Study I assessed the cognitive effects of low and high doses of EE, delivered tonically via a subcutaneous osmotic pump. Study II evaluated the cognitive effects of low, medium, and high doses of EE administered via a daily subcutaneous injection, modeling the daily rise and fall of serum EE levels with oral regimens. Study II also investigated the impact of low, medium and high doses of EE on the basal forebrain cholinergic system. The low and medium doses utilized here correspond to the range of doses currently used in clinical formulations, and the high dose corresponds to doses prescribed to a generation of women between 1960 and 1970, when oral contraceptives first became available. We evaluate cognition using a battery of maze tasks tapping several domains of spatial learning and memory as well as basal forebrain cholinergic integrity using immunohistochemistry and unbiased stereology to estimate the number of choline acetyltransferase (ChAT)-producing cells in the medial septum and vertical/diagonal bands. At the highest dose, EE treatment impaired multiple domains of spatial memory relative to vehicle treatment, regardless of administration method. When given cyclically at the low and medium doses, EE did not impact working memory, but transiently impaired reference memory during the learning phase of testing. Of the doses and regimens tested here, only EE at the highest dose impaired several domains of memory; tonic delivery of low EE, a dose that corresponds to the most popular doses used in the clinic today, did not impact cognition on any measure. Both medium and high injection doses of EE reduced the number of ChAt-immunoreactive cells in the basal forebrain, and cell population estimates in the vertical/diagonal bands negatively correlated with working memory errors. Copyright © 2015 Elsevier Ltd. All rights reserved.

  2. Evaluation of 16 genotype-guided Warfarin Dosing Algorithms in 310 Korean Patients Receiving Warfarin Treatment: Poor Prediction Performance in VKORC1 1173C Carriers.

    PubMed

    Yang, Mina; Choi, Rihwa; Kim, June Soo; On, Young Keun; Bang, Oh Young; Cho, Hyun-Jung; Lee, Soo-Youn

    2016-12-01

    The purpose of this study was to evaluate the performance of 16 previously published warfarin dosing algorithms in Korean patients. The 16 algorithms were selected through a literature search and evaluated using a cohort of 310 Korean patients with atrial fibrillation or cerebral infarction who were receiving warfarin therapy. A large interindividual variation (up to 11-fold) in warfarin dose was observed (median, 25 mg/wk; range, 7-77 mg/wk). Estimated dose and actual maintenance dose correlated well overall (r range, 0.52-0.73). Mean absolute error (MAE) of the 16 algorithms ranged from -1.2 to -20.1 mg/wk. The percentage of patients whose estimated dose fell within 20% of the actual dose ranged from 1.0% to 49%. All algorithms showed poor accuracy with increased MAE in a higher dose range. Performance of the dosing algorithms was worse in patients with VKORC1 1173TC or CC than in total (r range, 0.38-0.61 vs 0.52-0.73; MAE range, -2.6 to -28.0 mg/wk vs -1.2 to -20.1 mg/wk). The algorithms had comparable prediction abilities but showed limited accuracy depending on ethnicity, warfarin dose, and VKORC1 genotype. Further studies are needed to develop genotype-guided warfarin dosing algorithms with greater accuracy in the Korean population. Copyright © 2016 Elsevier HS Journals, Inc. All rights reserved.

  3. SU-F-T-461: Dosimetric Evaluation of Indigenous Farmer Type Chamber FAR65- GB for Reference Dosimetry of FFF MV Photon Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Patwe, P; Mhatre, V; Dandekar, P

    Purpose: Indigenous Farmer type chamber FAR 65 GB is a reference class 0.6 cc ion chamber. It can be used for dosimetric evaluation of photon and high energy electron beams. We studied dosimetric characteristics of the chamber for 6MV and 10MV Flattening filter free FFF photon beams available on trueBEAM STx Linac. Methods: The study was carried out on trueBEAM STx Linac having 6 and 10 MV FFF photon beam with maximum dose rate 1400 and 2400 MU per min respectively. The dosimetric device to be evaluated is Rosalina Instruments FAR 65-GB Ion Chamber with active volume 0.65 cc, totalmore » active length 23.1cm, inner diameter of cylinder 6.2mm, wall thickness 0.4mm, inner electrode diameter 1mm. Inner and outer electrodes are made from Aluminium 2.7 gm per cc and graphite 1.82 gm per cc respectively. The ion chamber was placed along central axis of beam at 10cm depth and irradiated for 10cm × 10cm field size at SAD of 100 cm in plastic phantom. We studied Precision, Dose Linearity, Dose Rate dependence, directional dependence, Recombination effect. Recombination effect was determined using standard two-voltage method. Results: 1. Measurements were reproducible std deviation of 0.0105 and type A uncertainty 0.003265 under same set of reference conditions 2. Chamber exhibit dose linearity over a wider dose range. 3. Chamber shows dose rate independence for all available dose rate range. 4. Response of chamber with the angle of incidence of radiation is constant. 5. Recombination correction factors were 1.01848 and 1.02537 for dose rate 1400 and 2400 MU per min resp. Conclusion: Our study reveals that the chamber is prone to saturation effect at dose rate of 2400 MU per min. FAR 65-GB can be used for reference dosimetry of FFF MV photon beam with proper calculation of recombination effect.« less

  4. The susceptibility of TaO x-based memristors to high dose rate ionizing radiation and total ionizing dose

    DOE PAGES

    McLain, Michael Lee; Sheridan, Timothy J.; Hjalmarson, Harold Paul; ...

    2014-11-11

    This paper investigates the effects of high dose rate ionizing radiation and total ionizing dose (TID) on tantalum oxide (TaO x) memristors. Transient data were obtained during the pulsed exposures for dose rates ranging from approximately 5.0 ×10 7 rad(Si)/s to 4.7 ×10 8 rad(Si)/s and for pulse widths ranging from 50 ns to 50 μs. The cumulative dose in these tests did not appear to impact the observed dose rate response. Static dose rate upset tests were also performed at a dose rate of ~3.0 ×10 8 rad(Si)/s. This is the first dose rate study on any type ofmore » memristive memory technology. In addition to assessing the tolerance of TaO x memristors to high dose rate ionizing radiation, we also evaluated their susceptibility to TID. The data indicate that it is possible for the devices to switch from a high resistance off-state to a low resistance on-state in both dose rate and TID environments. The observed radiation-induced switching is dependent on the irradiation conditions and bias configuration. Furthermore, the dose rate or ionizing dose level at which a device switches resistance states varies from device to device; the enhanced susceptibility observed in some devices is still under investigation. As a result, numerical simulations are used to qualitatively capture the observed transient radiation response and provide insight into the physics of the induced current/voltages.« less

  5. SU-F-T-130: [18F]-FDG Uptake Dose Response in Lung Correlates Linearly with Proton Therapy Dose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, D; Titt, U; Mirkovic, D

    2016-06-15

    Purpose: Analysis of clinical outcomes in lung cancer patients treated with protons using 18F-FDG uptake in lung as a measure of dose response. Methods: A test case lung cancer patient was selected in an unbiased way. The test patient’s treatment planning and post treatment positron emission tomography (PET) were collected from picture archiving and communication system at the UT M.D. Anderson Cancer Center. Average computerized tomography scan was registered with post PET/CT through both rigid and deformable registrations for selected region of interest (ROI) via VelocityAI imaging informatics software. For the voxels in the ROI, a system that extracts themore » Standard Uptake Value (SUV) from PET was developed, and the corresponding relative biological effectiveness (RBE) weighted (both variable and constant) dose was computed using the Monte Carlo (MC) methods. The treatment planning system (TPS) dose was also obtained. Using histogram analysis, the voxel average normalized SUV vs. 3 different doses was obtained and linear regression fit was performed. Results: From the registration process, there were some regions that showed significant artifacts near the diaphragm and heart region, which yielded poor r-squared values when the linear regression fit was performed on normalized SUV vs. dose. Excluding these values, TPS fit yielded mean r-squared value of 0.79 (range 0.61–0.95), constant RBE fit yielded 0.79 (range 0.52–0.94), and variable RBE fit yielded 0.80 (range 0.52–0.94). Conclusion: A system that extracts SUV from PET to correlate between normalized SUV and various dose calculations was developed. A linear relation between normalized SUV and all three different doses was found.« less

  6. SU-E-T-115: Dose Perturbation Study of Self-Expandable Metal and Polyester Esophageal Stents in Proton Therapy Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, S; Li, Z; Jalaj, S

    2014-06-01

    Purpose: This work investigates dose perturbations due to Self-expandable metal and polyester esophageal stents undergoing proton radiotherapy for esophageal cancer. Methods: Five commercially available esophageal stents made of nitinol (Evolution, Wallflex and Ultraflex), stainless steel (Z-Stent) and polyester (Polyflex) were tested. Radiochromic film (GafChromic EBT3 film, Ashland, Covington, KY) wrapped around a stent and a 12cc syringe was irradiated with 2CGE (Cobalt Gray Equivalent) of proton beam in a custom fabricated acrylic phantom. An air-hollow syringe simulates the esophagus. Results: The Z-stent created the largest dose perturbations ranges from -14.5% to 6.1% due to the steel composition. The WallFlex, Evolutionmore » and Ultraflex stents produced the dose perturbation ranges of (−9.2%∼8.6%), (−6.8%∼5.7%) and (−6.2%∼6.2%), respectively. The PolyFlex stent contains the radiopaque tungsten markers located top, middle and bottom portions. When the focal cold spots induced by the markers were excluded in the analysis, the dose perturbation range was changed from (−11.6%∼6.4%) to (−0.6%∼5.0%). Conclusion: The magnitude of dose perturbation is related to material of a metallic stent. The non-metallic stent such as PolyFlex shows relatively lower dose perturbation than metallic stents except a radiopaque marker region. Overall Evolution and Ultraflex stent appear to be less dose perturbations. The largest dose perturbations (cold spots) were located at both edges of stents in distal area for the single proton beam irradiation study. The analysis of more than two proton beam which is more typical clinical beam arrangement would be necessary to minimize the doe perturbation effect in proton ratiotherapy.« less

  7. Equivalence in Dose Fall-Off for Isocentric and Nonisocentric Intracranial Treatment Modalities and Its Impact on Dose Fractionation Schemes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ma Lijun, E-mail: lijunma@radonc.ucsf.ed; Sahgal, Arjun; Descovich, Martina

    2010-03-01

    Purpose: To investigate whether dose fall-off characteristics would be significantly different among intracranial radiosurgery modalities and the influence of these characteristics on fractionation schemes in terms of normal tissue sparing. Methods and Materials: An analytic model was developed to measure dose fall-off characteristics near the target independent of treatment modalities. Variations in the peripheral dose fall-off characteristics were then examined and compared for intracranial tumors treated with Gamma Knife, Cyberknife, or Novalis LINAC-based system. Equivalent uniform biologic effective dose (EUBED) for the normal brain tissue was calculated. Functional dependence of the normal brain EUBED on varying numbers of fractions (1more » to 30) was studied for the three modalities. Results: The derived model fitted remarkably well for all the cases (R{sup 2} > 0.99). No statistically significant differences in the dose fall-off relationships were found between the three modalities. Based on the extent of variations in the dose fall-off curves, normal brain EUBED was found to decrease with increasing number of fractions for the targets, with alpha/beta ranging from 10 to 20. This decrease was most pronounced for hypofractionated treatments with fewer than 10 fractions. Additionally, EUBED was found to increase slightly with increasing number of fractions for targets with alpha/beta ranging from 2 to 5. Conclusion: Nearly identical dose fall-off characteristics were found for the Gamma Knife, Cyberknife, and Novalis systems. Based on EUBED calculations, normal brain sparing was found to favor hypofractionated treatments for fast-growing tumors with alpha/beta ranging from 10 to 20 and single fraction treatment for abnormal tissues with low alpha/beta values such as alpha/beta = 2.« less

  8. Radiation optic neuropathy after megavoltage external-beam irradiation: Analysis of time-dose factors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parsons, J.T.; Bova, F.J.; Million, R.R.

    1994-11-15

    To investigate the risk of radiation-induced optic neuropathy according to total radiotherapy dose and fraction size, based on both retrospective and prospectively collected data. Between October 1964 and May 1989, 215 optic nerves in 131 patients received fractionated external-beam irradiation during the treatment of primary extracranial head and neck tumors. All patients had a minimum of 3 years of ophthalmologic follow-up (range, 3 to 21 years). The clinical end point was visual acuity of 20/100 or worse as a result of optic nerve injury. Anterior ischemic optic neuropathy developed in five nerves (at mean and median times of 32 andmore » 30 months, respectively, and a range of 2-4 years). Retrobulbar optic neuropathy developed in 12 nerves (at mean and median times of 47 and 28 months, respectively, and a range of 1-14 years). No injuries were observed in 106 optic nerves that received a total dose of <59 Gy. Among nerves that received doses of {ge} 60 Gy, the dose per fraction was more important than the total dose in producing optic neuropathy. The 15-year actuarial risk of optic compared with 47% when given in fraction sizes {ge}1.9 Gy. The data also suggest an increased risk of optic nerve injury with increasing age. As there is no effective treatment of radiation-induced optic neuropathy, efforts should be directed at its prevention by minimizing the total dose, paying attention to the dose per fraction to the nerve, and using reduced field techniques where appropriate to limit the volume of tissues that receive high-dose irradiation. 32 refs., 5 figs., 5 tabs.« less

  9. Effect of aerosol fenoterol on the severity of bronchial hyperreactivity in patients with asthma.

    PubMed Central

    Salome, C M; Schoeffel, R E; Yan, K; Woolcock, A J

    1983-01-01

    Beta adrenergic agents given by aerosol decrease the responsiveness of the airways to histamine and methacholine in subjects with asthma, causing a shift of the dose response curve to the right. To find out whether the shift is related to the dose of beta adrenergic agent given and to determine the duration of the reduced responsiveness, eight subjects with asthma were given histamine inhalation tests after inhaled saline and after increasing doses of inhaled fenoterol on different days. The histamine inhalation tests were repeated at hourly intervals for five hours after a selected dose of fenoterol. Fenoterol caused a dose related shift to the right of the histamine dose response curve in each subject and in some the dose response relationship reached the "non-symptomatic range." The shift in the dose response curve was short lived and had returned towards the control position within three hours in all subjects. There was no change in shape of the curves at the time of maximal shift. The results show that inhaled fenoterol greatly reduces the airway responsiveness to histamine, but up to 400 micrograms of fenoterol every four to five hours may be needed to keep the responsiveness of the airways in the non-symptomatic range. PMID:6648868

  10. Public member dose assessment of Bushehr Nuclear Power Plant under normal operation by modeling the fallout from stack using the HYSPLIT atmospheric dispersion model.

    PubMed

    Zali, A; Shamsaei Zafarghandi, M; Feghhi, S A; Taherian, A M

    2017-05-01

    In this work, public dose resulting from fission products released from Bushehr Nuclear Power Plant (BNPP) under normal operation is assessed. Due to the long range transport of radionuclides in this work (80 km) and considering terrain and meteorological data, HYbrid Single-Particle Lagrangian Integrated Trajectory (HYsplit) model, which uses three dimensional long-range numerical models, has been employed to calculate atmospheric dispersion. Annual effective dose calculation is carried out for inhalation, ingestion, and external exposure pathways in 16directions and within 80 km around the site for representative person. The results showed the maximum dose of inhalation and external exposure for adults is 3.8 × 10 -8 Sv/y in the SE direction and distance of 600 m from the BNPP site which is less than ICRP 103 recommended dose limit (1 mSv). Children and infants' doses are higher in comparison with adults, although they are less than 1 mSv. Ingestion dose percentage in the total dose is less than 0.1%. The results of this study underestimate the Final Safety Analysis Report ofBNPP-1 (FSAR)data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Optimisation of environmental remediation: how to select and use the reference levels.

    PubMed

    Balonov, M; Chipiga, L; Kiselev, S; Sneve, M; Yankovich, T; Proehl, G

    2018-06-01

    A number of past industrial activities and accidents have resulted in the radioactive contamination of large areas at many sites around the world, giving rise to a need for remediation. According to the International Commission on Radiological Protection (ICRP) and International Atomic Energy Agency (IAEA), such situations should be managed as existing exposure situations (ExESs). Control of exposure to the public in ExESs is based on the application of appropriate reference levels (RLs) for residual doses. The implementation of this potentially fruitful concept for the optimisation of remediation in various regions is hampered by a lack of practical experience and relevant guidance. This paper suggests a generic methodology for the selection of numeric values of relevant RLs both in terms of residual annual effective dose and derived RLs (DRLs) based on an appropriate dose assessment. The value for an RL should be selected in the range of the annual residual effective dose of 1-20 mSv, depending on the prevailing circumstances for the exposure under consideration. Within this range, RL values should be chosen by the following assessment steps: (a) assessment of the projected dose, i.e. the dose to a representative person without remedial actions by means of a realistic model as opposed to a conservative model; (b) modelling of the residual dose to a representative person following application of feasible remedial actions; and (c) selection of an RL value between the projected and residual doses, taking account of the prevailing social and economic conditions. This paper also contains some recommendations for practical implementation of the selected RLs for the optimisation of public protection. The suggested methodology used for the selection of RLs (in terms of dose) and the calculation of DRLs (in terms of activity concentration in food, ambient dose rate, etc) has been illustrated by a retrospective analysis of post-Chernobyl monitoring and modelling data from the Bryansk region, Russia, 2001. From this example, it follows that analysis of real data leads to the selection of an RL from a relatively narrow annual dose range (in this case, about 2-3 mSv), from which relevant DRLs can be calculated and directly used for optimisation of the remediation programme.

  12. Single dose x irradiation and concomitant hyperthermia on a murine fibroscarcoma. [Sensitizing effects of hyperthermia on tumors in mice subjected to local radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hahn, E.W.; Alfieri, A.A.; Kim, J.H.

    1978-12-01

    The objectives of this study were to quantitate the effects of local tumor hyperthermia (LTH) and concomitant x irradiation (RAD) on a moderately radioresistant murine fibrosarcoma in situ. Comparisons were made to the combined treatment response on the Ridgway osteogenic sarcoma, a radiosensitive tumor previously used in this laboratory and to establish the Meth-A fibrosarcoma as a model system for combined modality studies. 1.0 cm/sup 3/ tumors were exposed to single doses of RAD ranging from 0.5 to 3.8 krad alone or 0.5 to 2.3 krad in combination with LTH (water bath at 43.1 +- .05 C for 20 minutes)more » applied immediately postirradiation. LTH significantly enhanced the action of radiation as measured by tumor volume analysis, mean survival time and cures. The ratio of radiation doses vs. RAD + LTH required to produce an equivalent response ranged from 1.4 to 2.5 depending upon the endpoints evaluated. These findings are consistent with single dose studies on the radiosensitive Ridgway osteogenic sarcoma and suggest that the tumoricidal effectiveness of combination radiation and hyperthermia cannot be predicted on the basis of the radiation alone responsiveness of tumor.« less

  13. Acute Lethality after Fast-Neutron and X-Irradiation of Tribolium confusum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Glenn, Norman D.; Ducoff, Howard S.

    1976-01-01

    The acute lethal effects of fast neutrons and of X-rays on adults and larvae of T. confusum are compared. The time course of mortality of adults of the Oklahoma strain was the same after midlethal doses of neutrons and X-rays, although the neutrons were about twice as effective as X-rays in producing lethality, based on LD 50(35). The neutron RBE for adults of the Ebony mutant strain was also about 2, but that for Oklahoma larvae was about 3.85. Larvae surviving midlethal doses of neutrons showed a tendency toward wing abnormalities and delayed pupation. Dose-fractionation recovery with neutron doses inmore » the midlethal range was not detectable in the adults or in the larvae. A considerable sparing effect of dose fractionation was found in X-irradiated adults. Finally, also presented are techniques for using a beam port of a Triga research reactor for fast-neutron irradiation and a method of neutron and gamma dosimetry.« less

  14. New approach to CT pixel-based photon dose calculations in heterogeneous media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wong, J.W.; Henkelman, R.M.

    The effects of small cavities on dose in water and the dose in a homogeneous nonunit density medium illustrate that inhomogeneities do not act independently in photon dose perturbation, and serve as two constraints which should be satisfied by approximate methods of computed tomography (CT) pixel-based dose calculations. Current methods at best satisfy only one of the two constraints and show inadequacies in some intermediate geometries. We have developed an approximate method that satisfies both these constraints and treats much of the synergistic effect of multiple inhomogeneities correctly. The method calculates primary and first-scatter doses by first-order ray tracing withmore » the first-scatter contribution augmented by a component of second scatter that behaves like first scatter. Multiple-scatter dose perturbation values extracted from small cavity experiments are used in a function which approximates the small residual multiple-scatter dose. For a wide range of geometries tested, our method agrees very well with measurements. The average deviation is less than 2% with a maximum of 3%. In comparison, calculations based on existing methods can have errors larger than 10%.« less

  15. Methotrimeprazine for the management of end-of-life symptoms in infants and children.

    PubMed

    Hohl, Christopher M; Stenekes, Simone; Harlos, Michael S; Shepherd, Erin; McClement, Susan; Chochinov, Harvey Max

    2013-01-01

    This retrospective chart review assessed the efficacy, dose, and safety of methotrimeprazine in palliating end-of-life symptoms in children and infants. A retrospective chart review was conducted of 18 hospitalized pediatric patients who were treated with methotrimeprazine in their last two weeks of life. Data collected included age, diagnosis, symptoms, methotrimeprazine dose, route, efficacy, and any documented adverse effects. Patients' ages ranged from 16 days to 17 years. Underlying conditions included malignancies, trauma, and various neurodegenerative and congenital diseases. All patients (n = 18) were treated for symptoms of agitation, delirium, or restlessness. Most patients also experienced respiratory secretions/congestion (n = 15), pain (n = 13), and/ or dyspnea (n = 9). Less common symptoms included nausea/emesis (n = 5) and spasticity (n = 1). Methotrimeprazine dosages ranged from 0.02 mg/kg/dose to 0.5 mg/kg/dose. Routes of administration included intravenous (n = 13), oral/gastrostomy tube (n = 6), or subcutaneous (n = 4). Sedation (n = 6) was the only documented adverse effect, although when agitation was present, this was potentially an intended and perceived-to-be-beneficial effect. Methotrimeprazine, an old drug with diverse receptor activity and multiple routes of administration, appears to be an effective tool in treating complicated end-of-life symptoms in children and infants. This study provides a foundation for analysis with prospective and comparative trials, which may further quantify its benefit.

  16. A Case Report: Subanesthetic Ketamine Infusion for Treatment of Cancer-Related Pain Produces Urinary Urge Incontinence.

    PubMed

    Vickers, Barbara A; Lee, Wayne; Hunsberger, Joann

    2017-05-01

    Oncology patients undergoing treatment can experience substantial pain related to their disease or prescribed therapy. Ketamine infusions at subanesthetic doses have been used at our institution to supplement the pain management regimens of 262 patients. We present 2 cases in which young adult patients being treated with subanesthetic ketamine for cancer-related pain experienced urinary urgency and incontinence after initiation or increase of the ketamine infusion. This adverse effect has not been reported previously at this dosing range. These case reports suggest that subanesthetic ketamine infusions may cause side effects that previously have been reported only at anesthetic or abuse doses.

  17. An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning.

    PubMed

    Warren, Samantha; Partridge, Mike; Bolsi, Alessandra; Lomax, Anthony J; Hurt, Chris; Crosby, Thomas; Hawkins, Maria A

    2016-05-01

    Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV)50Gy or PTV62.5Gy (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose-volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D98 was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D98 was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D98 was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D98 was lower by 0.3% to 2.2% of the prescribed GTV dose. The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  18. Effect of bevacizumab on angiogenesis and growth of canine osteosarcoma cells xenografted in athymic mice.

    PubMed

    Scharf, Valery F; Farese, James P; Coomer, Alastair R; Milner, Rowan J; Taylor, David P; Salute, Marc E; Chang, Myron N; Neal, Dan; Siemann, Dietmar W

    2013-05-01

    Objective-To investigate the effects of bevacizumab, a human monoclonal antibody against vascular endothelial growth factor, on the angiogenesis and growth of canine osteosarcoma cells xenografted in mice. Animals-27 athymic nude mice. Procedures-To each mouse, highly metastasizing parent osteosarcoma cells of canine origin were injected into the left gastrocnemius muscle. Each mouse was then randomly allocated to 1 of 3 treatment groups: high-dose bevacizumab (4 mg/kg, IP), low-dose bevacizumab (2 mg/kg, IP), or control (no treatment). Tumor growth (the number of days required for the tumor to grow from 8 to 13 mm), vasculature, histomorphology, necrosis, and pulmonary metastasis were evaluated. Results-Mice in the high-dose bevacizumab group had significantly delayed tumor growth (mean ± SD, 13.4 ± 3.8 days; range, 9 to 21 days), compared with that for mice in the low-dose bevacizumab group (mean ± SD, 9.4 ± 1.5 days; range, 7 to 11 days) or control group (mean ± SD, 7. 2 ± 1.5 days; range, 4 to 9 days). Mice in the low-dose bevacizumab group also had significantly delayed tumor growth, compared with that for mice in the control group. Conclusions and Clinical Relevance-Results indicated that bevacizumab inhibited growth of canine osteosarcoma cells xenografted in mice, which suggested that vascular endothelial growth factor inhibitors may be clinically useful for the treatment of osteosarcoma in dogs. Impact for Human Medicine-Canine osteosarcoma is used as a research model for human osteosarcoma; therefore, bevacizumab may be clinically beneficial for the treatment of osteosarcoma in humans.

  19. Nuclear energy and health: and the benefits of low-dose radiation hormesis.

    PubMed

    Cuttler, Jerry M; Pollycove, Myron

    2009-01-01

    Energy needs worldwide are expected to increase for the foreseeable future, but fuel supplies are limited. Nuclear reactors could supply much of the energy demand in a safe, sustainable manner were it not for fear of potential releases of radioactivity. Such releases would likely deliver a low dose or dose rate of radiation, within the range of naturally occurring radiation, to which life is already accustomed. The key areas of concern are discussed. Studies of actual health effects, especially thyroid cancers, following exposures are assessed. Radiation hormesis is explained, pointing out that beneficial effects are expected following a low dose or dose rate because protective responses against stresses are stimulated. The notions that no amount of radiation is small enough to be harmless and that a nuclear accident could kill hundreds of thousands are challenged in light of experience: more than a century with radiation and six decades with reactors. If nuclear energy is to play a significant role in meeting future needs, regulatory authorities must examine the scientific evidence and communicate the real health effects of nuclear radiation. Negative images and implications of health risks derived by unscientific extrapolations of harmful effects of high doses must be dispelled.

  20. Nuclear Energy and Health: And the Benefits of Low-Dose Radiation Hormesis

    PubMed Central

    Cuttler, Jerry M.; Pollycove, Myron

    2009-01-01

    Energy needs worldwide are expected to increase for the foreseeable future, but fuel supplies are limited. Nuclear reactors could supply much of the energy demand in a safe, sustainable manner were it not for fear of potential releases of radioactivity. Such releases would likely deliver a low dose or dose rate of radiation, within the range of naturally occurring radiation, to which life is already accustomed. The key areas of concern are discussed. Studies of actual health effects, especially thyroid cancers, following exposures are assessed. Radiation hormesis is explained, pointing out that beneficial effects are expected following a low dose or dose rate because protective responses against stresses are stimulated. The notions that no amount of radiation is small enough to be harmless and that a nuclear accident could kill hundreds of thousands are challenged in light of experience: more than a century with radiation and six decades with reactors. If nuclear energy is to play a significant role in meeting future needs, regulatory authorities must examine the scientific evidence and communicate the real health effects of nuclear radiation. Negative images and implications of health risks derived by unscientific extrapolations of harmful effects of high doses must be dispelled. PMID:19343116

  1. Efficiency and effectiveness of the use of an acenocoumarol pharmacogenetic dosing algorithm versus usual care in patients with venous thromboembolic disease initiating oral anticoagulation: study protocol for a randomized controlled trial

    PubMed Central

    2012-01-01

    Background Hemorrhagic events are frequent in patients on treatment with antivitamin-K oral anticoagulants due to their narrow therapeutic margin. Studies performed with acenocoumarol have shown the relationship between demographic, clinical and genotypic variants and the response to these drugs. Once the influence of these genetic and clinical factors on the dose of acenocoumarol needed to maintain a stable international normalized ratio (INR) has been demonstrated, new strategies need to be developed to predict the appropriate doses of this drug. Several pharmacogenetic algorithms have been developed for warfarin, but only three have been developed for acenocoumarol. After the development of a pharmacogenetic algorithm, the obvious next step is to demonstrate its effectiveness and utility by means of a randomized controlled trial. The aim of this study is to evaluate the effectiveness and efficiency of an acenocoumarol dosing algorithm developed by our group which includes demographic, clinical and pharmacogenetic variables (VKORC1, CYP2C9, CYP4F2 and ApoE) in patients with venous thromboembolism (VTE). Methods and design This is a multicenter, single blind, randomized controlled clinical trial. The protocol has been approved by La Paz University Hospital Research Ethics Committee and by the Spanish Drug Agency. Two hundred and forty patients with VTE in which oral anticoagulant therapy is indicated will be included. Randomization (case/control 1:1) will be stratified by center. Acenocoumarol dose in the control group will be scheduled and adjusted following common clinical practice; in the experimental arm dosing will be following an individualized algorithm developed and validated by our group. Patients will be followed for three months. The main endpoints are: 1) Percentage of patients with INR within the therapeutic range on day seven after initiation of oral anticoagulant therapy; 2) Time from the start of oral anticoagulant treatment to achievement of a stable INR within the therapeutic range; 3) Number of INR determinations within the therapeutic range in the first six weeks of treatment. Discussion To date, there are no clinical trials comparing pharmacogenetic acenocoumarol dosing algorithm versus routine clinical practice in VTE. Implementation of this pharmacogenetic algorithm in the clinical practice routine could reduce side effects and improve patient safety. Trial registration Eudra CT. Identifier: 2009-016643-18. PMID:23237631

  2. The Effect of Electron Beam Irradiation in Environmental Scanning Transmission Electron Microscopy of Whole Cells in Liquid.

    PubMed

    Hermannsdörfer, Justus; Tinnemann, Verena; Peckys, Diana B; de Jonge, Niels

    2016-06-01

    Whole cells can be studied in their native liquid environment using electron microscopy, and unique information about the locations and stoichiometry of individual membrane proteins can be obtained from many cells thus taking cell heterogeneity into account. Of key importance for the further development of this microscopy technology is knowledge about the effect of electron beam radiation on the samples under investigation. We used environmental scanning electron microscopy (ESEM) with scanning transmission electron microscopy (STEM) detection to examine the effect of radiation for whole fixed COS7 fibroblasts in liquid. The main observation was the localization of nanoparticle labels attached to epidermal growth factor receptors (EGFRs). It was found that the relative distances between the labels remained mostly unchanged (<1.5%) for electron doses ranging from the undamaged native state at 10 e-/Å2 toward 103 e-/Å2. This dose range was sufficient to determine the EGFR locations with nanometer resolution and to distinguish between monomers and dimers. Various different forms of radiation damage became visible at higher doses, including severe dislocation, and the dissolution of labels.

  3. Fluoroscopically Guided Interventional Procedures: A Review of Radiation Effects on Patients’ Skin and Hair

    DTIC Science & Technology

    2010-02-01

    subsequent research has yielded additional in- sights. This review is a consensus report of current scien- tifi c data. Expected skin reactions for an...table has been cited and reproduced Essentials The minimum radiation dose n causing a specifi c type of reac- tion in the skin or hair is best...expressed in terms of a range of doses, rather than a single threshold dose. The times of onset and resolution n of specifi c radiation injuries

  4. 210-Polonium studies in some environmental and biological matrices of Domiasiat uranium deposit area, West Khasi Hills, Meghalaya, India.

    PubMed

    Marbaniang, Deswyn G; Poddar, Raj K; Nongkynrih, Phlis; Khathing, Darlando T

    2010-03-01

    The study was performed using a silicon surface barrier alpha spectrometer at Bhabha Atomic Research Centre, Mumbai, India. Through the study, the observed (210)Po activity in water sample from different locations in the Domiasiat area ranges from 0.04 to 0.69 Bq/l. The daily and annual intake of (210)Po through water was also estimated and the mean value of 0.72 and 263.61 Bq, respectively, were observed. It is observed that the effective doses through water were higher than the World Health Organization recommended dose of 0.05 mSv/year. The total annual effective doses through terrestrial ingestion for all the locations was studied and the mean annual effective dose was observed to be 0.315 mSv, which, when compared to the worldwide and the Indian values, was observed to be slightly higher. The mean activity in soil is found to be 124.8 +/-5.7 Bq/kg and in meat the activity is 0.43 +/-0.05 Bq/kg. In fishes, an activity of 0.48 +/-0.07 Bq/kg in Garra lamta, 0.29 +/-0.02 Bq/kg in Neolissocheilus hexaganolepis, and 3.3 +/-0.1 Bq/kg in Macrobrachium sp. is observed. Activity concentration in plant samples was analyzed and the activity ranges from 0.020 +/-0.002 to 9.69 +/-0.35 Bq/kg. Committed effective dose by the adult population of the Domiasiat area through intake of (210)Po through these food items was also determined and compared with the Indian average value and the worldwide average value.

  5. Paradoxical effects of oxytocin and vasopressin on basal prolactin secretion and the estrogen-induced prolactin surge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mai, Leemin; Pan, Jenntser

    1990-01-01

    The roles of oxytocin (OT) and vasopressin (AVP) on both basal and estrogen-induced prolactin (PRL) secretion were examined. Adult female Sprague-Dawley rats that were ovariectomized for 3 weeks and received estrogen treatment for 1 week were used. Intravenous administration of hormones and serial blood sampling were accomplished through indwelling intraatrial catheters which were implanted two days before. Plasma PRL levels were measured by radioimmunoassay. Oxytocin at a dose of 20 {mu}g/rat stimulated a moderate PRL release in the morning and lower doses were without effect. Vasopressin was most effective at a dose of 5 {mu}g/rat in stimulating PRL release, whilemore » consecutive injections of higher doses were less effective. In contrast, TRH, ranging from 1 to 8 {mu}g/rat, induced a dose-dependent increases in PRL secretion. Using the effective dosages determined from the morning studies, repeated injections of either OT, AVP or their specific antagonists MPOMeOVT were given hourly between 1300 to 1800h and blood samples were obtained hourly from 1100 to 1900h. It was found that either OT or AVP significantly reduced the afternoon PRL surge, while their antagonists were not as effective.« less

  6. Potentiation of buprenorphine antinociception with ultra-low dose naltrexone in healthy subjects.

    PubMed

    Hay, J L; La Vincente, S F; Somogyi, A A; Chapleo, C B; White, J M

    2011-03-01

    Previous reports have demonstrated greater antinociception following administration of a buprenorphine/naloxone combination compared to buprenorphine alone among healthy volunteers. The aim of the current investigation was to determine whether buprenorphine antinociception could be enhanced with the addition of ultra-low dose naltrexone, using a range of dose ratios. A repeated-measures, double-blind, cross-over trial was undertaken with 10 healthy participants. The effects of each buprenorphine:naltrexone ratio (100:1, 133:1, 166:1, and 200:1) on cold pressor tolerance time and respiration were compared to the effects of buprenorphine only. The 166:1 ratio was associated with significantly greater tolerance time to cold pressor pain than buprenorphine alone. Minimal respiratory depression and few adverse events were observed in all conditions. These findings suggest that, as previously described with naloxone, the addition of ultra-low dose naltrexone can enhance the antinociceptive effect of buprenorphine in humans. This potentiation is dose-ratio dependent and occurs without a concomitant increase in adverse effects. Copyright © 2010 European Federation of International Association for the Study of Pain Chapters. Published by Elsevier Ltd. All rights reserved.

  7. Committed effective dose determination in southern Brazilian cereal flours.

    PubMed

    Scheibel, V; Appoloni, C R

    2013-01-01

    The health impact of radionuclide ingestion from foodstuffs was evaluated by the committed effective doses determined in eight commercial samples of South-Brazilian cereal flours (soy, wheat, cornmeal, cassava, rye, oat, barley and rice flours). The radioactivity traces of (228)Th, (228)Ra, (226)Ra, (40)K, (7)Be and (137)Cs were measured by gamma-ray spectrometry employing an HPGe detector of 66 % relative efficiency. The efficiency curve has taken into account the differences in densities and chemical composition between the matrix and the certified sample. The highest concentration levels of (228)Th and (40)K were 3.5±0.4 and 1469±17 Bq kg(-1) for soy flour, respectively, within the 95 % confidence level. The lower limit of detection for (137)Cs ranged from 0.04 to 0.4 Bq kg(-1). The highest committed effective dose was 0.36 μSv.y(-1) for (228)Ra in cassava flour (adults). All committed effective doses determined at the present work were lower than the International Atomic Energy Agency dose limit of 1 mSv.y(-1), to the public exposure.

  8. Histopathology and biochemistry analysis of the interaction between sunitinib and paracetamol in mice.

    PubMed

    Lim, Adeline Yl; Segarra, Ignacio; Chakravarthi, Srikumar; Akram, Sufyan; Judson, John P

    2010-10-15

    Sunitinib, a tyrosine kinase inhibitor to treat GIST and mRCC may interact with paracetamol as both undergo P450 mediated biotransformation and P-glycoprotein transport. This study evaluates the effects of sunitinib-paracetamol coadministration on liver and renal function biomarkers and liver, kidney, brain, heart and spleen histopathology. ICR male mice (n = 6 per group/dose) were administered saline (group-A) or paracetamol 500 mg/kg IP (group-B), or sunitinib at 25, 50, 80, 100, 140 mg/kg PO (group-C) or coadministered sunitinib at 25, 50, 80, 100, 140 mg/kg PO and paracetamol IP at fixed dose 500 mg/kg (group-D). Paracetamol was administered 15 min before sunitinib. Mice were sacrificed 4 h post sunitinib administration. Group-A serum ALT and AST levels were 14.29 ± 2.31 U/L and 160.37 ± 24.74 U/L respectively and increased to 249.6 ± 222.7 U/L and 377.1 ± 173.6 U/L respectively in group-B; group-C ALT and AST ranged 36.75-75.02 U/L and 204.4-290.3 U/L respectively. After paracetamol coadministration with low sunitinib doses (group-D), ALT and AST concentrations ranged 182.79-221.03 U/L and 259.7-264.4 U/L respectively, lower than group-B. Paracetamol coadministration with high sunitinib doses showed higher ALT and AST values (range 269.6-349.2 U/L and 430.2-540.3 U/L respectively), p < 0.05. Hepatic histopathology showed vascular congestion in group-B; mild congestion in group-C (but lesser than in group-B and D). In group-D, at low doses of sunitinib, lesser damage than in group-B occurred but larger changes including congestion were observed at high sunitinib doses. BUN levels were higher (p < 0.05) for group-B (33.81 ± 5.68 mg/dL) and group-D (range 35.01 ± 6.95 U/L to 52.85 ± 12.53 U/L) compared to group-A (15.60 ± 2.17 mg/dL) and group-C (range 17.50 ± 1.25 U/L to 26.68 ± 6.05 U/L). Creatinine remained unchanged. Renal congestion and necrosis was lower in group-C than group-B but was higher in group-D (p > 0.05). Mild cardiotoxicity occurred in groups B, C and D. Brain vascular congestion occurred at high doses of sunitinib administered alone or with paracetamol. Hepatic and renal biomarkers correlated with histopathology signs. Paracetamol and sunitinib coadministration may lead to dose dependent outcomes exhibiting mild hepatoprotective effect or increased hepatotoxicity. Sunitinib at high doses show renal, cardiac and brain toxicity. Liver and renal function monitoring is recommended.

  9. Histopathology and biochemistry analysis of the interaction between sunitinib and paracetamol in mice

    PubMed Central

    2010-01-01

    Background Sunitinib, a tyrosine kinase inhibitor to treat GIST and mRCC may interact with paracetamol as both undergo P450 mediated biotransformation and P-glycoprotein transport. This study evaluates the effects of sunitinib-paracetamol coadministration on liver and renal function biomarkers and liver, kidney, brain, heart and spleen histopathology. ICR male mice (n = 6 per group/dose) were administered saline (group-A) or paracetamol 500 mg/kg IP (group-B), or sunitinib at 25, 50, 80, 100, 140 mg/kg PO (group-C) or coadministered sunitinib at 25, 50, 80, 100, 140 mg/kg PO and paracetamol IP at fixed dose 500 mg/kg (group-D). Paracetamol was administered 15 min before sunitinib. Mice were sacrificed 4 h post sunitinib administration. Results Group-A serum ALT and AST levels were 14.29 ± 2.31 U/L and 160.37 ± 24.74 U/L respectively and increased to 249.6 ± 222.7 U/L and 377.1 ± 173.6 U/L respectively in group-B; group-C ALT and AST ranged 36.75-75.02 U/L and 204.4-290.3 U/L respectively. After paracetamol coadministration with low sunitinib doses (group-D), ALT and AST concentrations ranged 182.79-221.03 U/L and 259.7-264.4 U/L respectively, lower than group-B. Paracetamol coadministration with high sunitinib doses showed higher ALT and AST values (range 269.6-349.2 U/L and 430.2-540.3 U/L respectively), p < 0.05. Hepatic histopathology showed vascular congestion in group-B; mild congestion in group-C (but lesser than in group-B and D). In group-D, at low doses of sunitinib, lesser damage than in group-B occurred but larger changes including congestion were observed at high sunitinib doses. BUN levels were higher (p < 0.05) for group-B (33.81 ± 5.68 mg/dL) and group-D (range 35.01 ± 6.95 U/L to 52.85 ± 12.53 U/L) compared to group-A (15.60 ± 2.17 mg/dL) and group-C (range 17.50 ± 1.25 U/L to 26.68 ± 6.05 U/L). Creatinine remained unchanged. Renal congestion and necrosis was lower in group-C than group-B but was higher in group-D (p > 0.05). Mild cardiotoxicity occurred in groups B, C and D. Brain vascular congestion occurred at high doses of sunitinib administered alone or with paracetamol. Hepatic and renal biomarkers correlated with histopathology signs. Conclusions Paracetamol and sunitinib coadministration may lead to dose dependent outcomes exhibiting mild hepatoprotective effect or increased hepatotoxicity. Sunitinib at high doses show renal, cardiac and brain toxicity. Liver and renal function monitoring is recommended. PMID:20950441

  10. A pragmatic approach to determine the optimal kVp in cone beam CT: balancing contrast-to-noise ratio and radiation dose

    PubMed Central

    Silkosessak, O; Jacobs, R; Bogaerts, R; Bosmans, H; Panmekiate, S

    2014-01-01

    Objectives: To determine the optimal kVp setting for a particular cone beam CT (CBCT) device by maximizing technical image quality at a fixed radiation dose. Methods: The 3D Accuitomo 170 (J. Morita Mfg. Corp., Kyoto, Japan) CBCT was used. The radiation dose as a function of kVp was measured in a cylindrical polymethyl methacrylate (PMMA) phantom using a small-volume ion chamber. Contrast-to-noise ratio (CNR) was measured using a PMMA phantom containing four materials (air, aluminium, polytetrafluoroethylene and low-density polyethylene), which was scanned using 180 combinations of kVp/mA, ranging from 60/1 to 90/8. The CNR was measured for each material using PMMA as background material. The pure effect of kVp and mAs on the CNR values was analysed. Using a polynomial fit for CNR as a function of mA for each kVp value, the optimal kVp was determined at five dose levels. Results: Absorbed doses ranged between 0.034 mGy mAs−1 (14 × 10 cm, 60 kVp) and 0.108 mGy mAs−1 (14 × 10 cm, 90 kVp). The relation between kVp and dose was quasilinear (R2 > 0.99). The effect of mA and kVp on CNR could be modelled using a second-degree polynomial. At a fixed dose, there was a tendency for higher CNR values at increasing kVp values, especially at low dose levels. A dose reduction through mA was more efficient than an equivalent reduction through kVp in terms of image quality deterioration. Conclusions: For the investigated CBCT model, the most optimal contrast at a fixed dose was found at the highest available kVp setting. There is great potential for dose reduction through mA with a minimal loss in image quality. PMID:24708447

  11. SU-E-T-238: Monte Carlo Estimation of Cerenkov Dose for Photo-Dynamic Radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chibani, O; Price, R; Ma, C

    Purpose: Estimation of Cerenkov dose from high-energy megavoltage photon and electron beams in tissue and its impact on the radiosensitization using Protoporphyrine IX (PpIX) for tumor targeting enhancement in radiotherapy. Methods: The GEPTS Monte Carlo code is used to generate dose distributions from 18MV Varian photon beam and generic high-energy (45-MV) photon and (45-MeV) electron beams in a voxel-based tissueequivalent phantom. In addition to calculating the ionization dose, the code scores Cerenkov energy released in the wavelength range 375–425 nm corresponding to the pick of the PpIX absorption spectrum (Fig. 1) using the Frank-Tamm formula. Results: The simulations shows thatmore » the produced Cerenkov dose suitable for activating PpIX is 4000 to 5500 times lower than the overall radiation dose for all considered beams (18MV, 45 MV and 45 MeV). These results were contradictory to the recent experimental studies by Axelsson et al. (Med. Phys. 38 (2011) p 4127), where Cerenkov dose was reported to be only two orders of magnitude lower than the radiation dose. Note that our simulation results can be corroborated by a simple model where the Frank and Tamm formula is applied for electrons with 2 MeV/cm stopping power generating Cerenkov photons in the 375–425 nm range and assuming these photons have less than 1mm penetration in tissue. Conclusion: The Cerenkov dose generated by high-energy photon and electron beams may produce minimal clinical effect in comparison with the photon fluence (or dose) commonly used for photo-dynamic therapy. At the present time, it is unclear whether Cerenkov radiation is a significant contributor to the recently observed tumor regression for patients receiving radiotherapy and PpIX versus patients receiving radiotherapy only. The ongoing study will include animal experimentation and investigation of dose rate effects on PpIX response.« less

  12. Metabolomics reveals dose effects of low-dose chronic exposure to uranium in rats: identification of candidate biomarkers in urine samples.

    PubMed

    Grison, Stéphane; Favé, Gaëlle; Maillot, Matthieu; Manens, Line; Delissen, Olivia; Blanchardon, Éric; Dublineau, Isabelle; Aigueperse, Jocelyne; Bohand, Sandra; Martin, Jean-Charles; Souidi, Maâmar

    2016-01-01

    Data are sparse about the potential health risks of chronic low-dose contamination of humans by uranium (natural or anthropogenic) in drinking water. Previous studies report some molecular imbalances but no clinical signs due to uranium intake. In a proof-of-principle study, we reported that metabolomics is an appropriate method for addressing this chronic low-dose exposure in a rat model (uranium dose: 40 mg L -1 ; duration: 9 months, n = 10). In the present study, our aim was to investigate the dose-effect pattern and identify additional potential biomarkers in urine samples. Compared to our previous protocol, we doubled the number of rats per group (n = 20), added additional sampling time points (3 and 6 months) and included several lower doses of natural uranium (doses used: 40, 1.5, 0.15 and 0.015 mg L -1 ). LC-MS metabolomics was performed on urine samples and statistical analyses were made with SIMCA-P+ and R packages. The data confirmed our previous results and showed that discrimination was both dose and time related. Uranium exposure was revealed in rats contaminated for 9 months at a dose as low as 0.15 mg L -1 . Eleven features, including the confidently identified N1-methylnicotinamide, N1-methyl-2-pyridone-5-carboxamide and 4-hydroxyphenylacetylglycine, discriminated control from contaminated rats with a specificity and a sensitivity ranging from 83 to 96 %, when combined into a composite score. These findings show promise for the elucidation of underlying radiotoxicologic mechanisms and the design of a diagnostic test to assess exposure in urine, in a dose range experimentally estimated to be above a threshold between 0.015 and 0.15 mg L -1 .

  13. The dose effects of short-term dronabinol (oral THC) maintenance in daily cannabis users.

    PubMed

    Vandrey, Ryan; Stitzer, Maxine L; Mintzer, Miriam Z; Huestis, Marilyn A; Murray, Jeannie A; Lee, Dayong

    2013-02-01

    Prior studies have separately examined the effects of dronabinol (oral THC) on cannabis withdrawal, cognitive performance, and the acute effects of smoked cannabis. A single study examining these clinically relevant domains would benefit the continued evaluation of dronabinol as a potential medication for the treatment of cannabis use disorders. Thirteen daily cannabis smokers completed a within-subject crossover study and received 0, 30, 60 and 120mg dronabinol per day for 5 consecutive days. Vital signs and subjective ratings of cannabis withdrawal, craving and sleep were obtained daily; outcomes under active dose conditions were compared to those obtained under placebo dosing. On the 5th day of medication maintenance, participants completed a comprehensive cognitive performance battery and then smoked five puffs of cannabis for subjective effects evaluation. Each dronabinol maintenance period occurred in a counterbalanced order and was separated by 9 days of ad libitum cannabis use. Dronabinol dose-dependently attenuated cannabis withdrawal and resulted in few adverse side effects or decrements in cognitive performance. Surprisingly, dronabinol did not alter the subjective effects of smoked cannabis, but cannabis-induced increases in heart rate were attenuated by the 60 and 120mg doses. Dronabinol's ability to dose-dependently suppress cannabis withdrawal may be therapeutically beneficial to individuals trying to stop cannabis use. The absence of gross cognitive impairment or side effects in this study supports safety of doses up to 120mg/day. Continued evaluation of dronabinol in targeted clinical studies of cannabis treatment, using an expanded range of doses, is warranted. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  14. The Dose Effects of Short-Term Dronabinol (Oral THC) Maintenance in Daily Cannabis Users

    PubMed Central

    Vandrey, Ryan; Stitzer, Maxine L.; Mintzer, Miriam Z.; Huestis, Marilyn A.; Murray, Jeannie A.; Lee, Dayong

    2012-01-01

    BACKGROUND Prior studies have separately examined the effects of dronabinol (oral THC) on cannabis withdrawal, cognitive performance, and the acute effects of smoked cannabis. A single study examining these clinically relevant domains would benefit the continued evaluation of dronabinol as a potential medication for the treatment of cannabis use disorders. METHODS Thirteen daily cannabis smokers completed a within-subject crossover study and received 0, 30, 60 and 120 mg dronabinol per day for 5 consecutive days. Vital signs and subjective ratings of cannabis withdrawal, craving and sleep were obtained daily; outcomes under active dose conditions were compared to those obtained under placebo dosing. On the 5th day of medication maintenance, participants completed a comprehensive cognitive performance battery and then smoked 5 puffs of cannabis for subjective effects evaluation. Each dronabinol maintenance period occurred in a counterbalanced order and was separated by 9 days of ad-libitum cannabis use. RESULTS Dronabinol dose-dependently attenuated cannabis withdrawal and resulted in few adverse side effects or decrements in cognitive performance. Surprisingly, dronabinol did not alter the subjective effects of smoked cannabis, but cannabis-induced increases in heart rate were attenuated by the 60 and 120 mg doses. CONCLUSIONS Dronabinol’s ability to dose-dependently suppress cannabis withdrawal may be therapeutically beneficial to individuals trying to stop cannabis use. The absence of gross cognitive impairment or side effects in this study supports safety of doses up to 120mg per day. Continued evaluation of dronabinol in targeted clinical studies of cannabis treatment, using an expanded range of doses, is warranted. PMID:22921474

  15. Estimated UV doses to psoriasis patients during climate therapy at Gran Canaria in March 2006

    NASA Astrophysics Data System (ADS)

    Nilsen, L. T. N.; Søyland, E.; Krogstad, A. L.

    2008-01-01

    Psoriasis is a chronic inflammatory disease involving about 2-3% of the Norwegian population. Sun exposure has a positive effect on most psoriasis lesions, but ultraviolet (UV) radiation also causes a direct DNA damage in the skin cells and comprises a carcinogenic potential. UV exposure on the skin causes a local as well as a systemic immune suppressive effect, but the relation between sun exposure and these biological effects is not well known. In March 2006 a study was carried out to investigate possible therapeutic outcome mechanisms in 20 psoriasis patients receiving climate therapy at Gran Canaria. This paper presents estimates of their individual skin UV-doses based on UV measurements and the patients' diaries with information on time spent in the sun. On the first day of exposure the patients received on average 5.1 Standard Erythema Doses (SED: median=4.0 SED, range 2.6-10.3 SED) estimated to the skin. During the 15 days study they received 165.8 SED (range 104.3-210.1 SED). The reduction in PASI score was 72.8% on average, but there was no obvious relation between the improvement and the UV dose. The UV doses were higher than those found from climate therapy studies at other locations. It seems beneficial to use more strict exposure schedules that consider the available UV irradiance, depending on time of the day, time of the year and weather conditions.

  16. The space radiation environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robbins, D E

    There are three primary sources of space radiation: galactic cosmic rays (GCR), trapped belt radiation, and solar particle events (SPE). All are composed of ions, the nuclei of atoms. Their energies range from a few MeV u{sup -1} to over a GeV u{sup -1}. These ions can fragment when they interact with spacecraft materials and produce energetic neutrons and ions of lower atomic mass. Absorbed dose rates inside a typical spacecraft (like the Space Shuttle) in a low inclination (28.5 degrees) orbit range between 0.05 and 2 mGy d{sup -1} depending on the altitude and flight inclination (angle of orbitmore » with the equator). The quality factor of radiation in orbit depends on the relative contributions of trapped belt radiation and GCR, and the dose rate varies both with orbital altitude and inclination. The corresponding equivalent dose rate ranges between 0.1 and 4 mSv d{sup -1}. In high inclination orbits, like that of the Mir Space Station and as is planned for the International Space Station, blood-forming organ (BFO) equivalent dose rates as high as 1.5 mSv d{sup -1}. Thus, on a 1 y mission, a crew member could obtain a total dose of 0.55 Sv. Maximum equivalent dose rates measured in high altitude passes through the South Atlantic Anomaly (SAA) were 10 mSv h{sup -1}. For an interplanetary space mission (e.g., to Mars) annual doses from GCR alone range between 150 mSv y{sup -1} at solar maximum and 580 mSv y{sup -1} at solar minimum. Large SPE, like the October 1989 series, are more apt to occur in the years around solar maximum. In free space, such an event could contribute another 300 mSv, assuming that a warning system and safe haven can be effectively used with operational procedures to minimize crew exposures. Thus, the total dose for a 3 y mission to Mars could exceed 2 Sv.« less

  17. Alternative calculations of individual patient time in therapeutic range while taking warfarin: results from the ROCKET AF trial.

    PubMed

    Singer, Daniel E; Hellkamp, Anne S; Yuan, Zhong; Lokhnygina, Yuliya; Patel, Manesh R; Piccini, Jonathan P; Hankey, Graeme J; Breithardt, Günter; Halperin, Jonathan L; Becker, Richard C; Hacke, Werner; Nessel, Christopher C; Mahaffey, Kenneth W; Fox, Keith A A; Califf, Robert M

    2015-03-03

    In the ROCKET AF (Rivaroxaban-Once-daily, oral, direct Factor Xa inhibition Compared with vitamin K antagonism for prevention of stroke and Embolism Trial in Atrial Fibrillation) trial, marked regional differences in control of warfarin anticoagulation, measured as the average individual patient time in the therapeutic range (iTTR) of the international normalized ratio (INR), were associated with longer inter-INR test intervals. The standard Rosendaal approach can produce biased low estimates of TTR after an appropriate dose change if the follow-up INR test interval is prolonged. We explored the effect of alternative calculations of TTR that more immediately account for dose changes on regional differences in mean iTTR in the ROCKET AF trial. We used an INR imputation method that accounts for dose change. We compared group mean iTTR values between our dose change-based method with the standard Rosendaal method and determined that the differences between approaches depended on the balance of dose changes that produced in-range INRs ("corrections") versus INRs that were out of range in the opposite direction ("overshoots"). In ROCKET AF, the overall mean iTTR of 55.2% (Rosendaal) increased up to 3.1% by using the dose change-based approach, depending on assumptions. However, large inter-regional differences in anticoagulation control persisted. TTR, the standard measure of control of warfarin anticoagulation, depends on imputing daily INR values for the vast majority of follow-up days. Our TTR calculation method may better reflect the impact of warfarin dose changes than the Rosendaal approach. In the ROCKET AF trial, this dose change-based approach led to a modest increase in overall mean iTTR but did not materially affect the large inter-regional differences previously reported. URL: ClinicalTrials.gov. Unique identifier: NCT00403767. © 2015 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley Blackwell.

  18. Alternative Calculations of Individual Patient Time in Therapeutic Range While Taking Warfarin: Results From the ROCKET AF Trial

    PubMed Central

    Singer, Daniel E.; Hellkamp, Anne S.; Yuan, Zhong; Lokhnygina, Yuliya; Patel, Manesh R.; Piccini, Jonathan P.; Hankey, Graeme J.; Breithardt, Günter; Halperin, Jonathan L.; Becker, Richard C.; Hacke, Werner; Nessel, Christopher C.; Mahaffey, Kenneth W.; Fox, Keith A. A.; Califf, Robert M.

    2015-01-01

    Background In the ROCKET AF (Rivaroxaban–Once‐daily, oral, direct Factor Xa inhibition Compared with vitamin K antagonism for prevention of stroke and Embolism Trial in Atrial Fibrillation) trial, marked regional differences in control of warfarin anticoagulation, measured as the average individual patient time in the therapeutic range (iTTR) of the international normalized ratio (INR), were associated with longer inter‐INR test intervals. The standard Rosendaal approach can produce biased low estimates of TTR after an appropriate dose change if the follow‐up INR test interval is prolonged. We explored the effect of alternative calculations of TTR that more immediately account for dose changes on regional differences in mean iTTR in the ROCKET AF trial. Methods and Results We used an INR imputation method that accounts for dose change. We compared group mean iTTR values between our dose change–based method with the standard Rosendaal method and determined that the differences between approaches depended on the balance of dose changes that produced in‐range INRs (“corrections”) versus INRs that were out of range in the opposite direction (“overshoots”). In ROCKET AF, the overall mean iTTR of 55.2% (Rosendaal) increased up to 3.1% by using the dose change–based approach, depending on assumptions. However, large inter‐regional differences in anticoagulation control persisted. Conclusions TTR, the standard measure of control of warfarin anticoagulation, depends on imputing daily INR values for the vast majority of follow‐up days. Our TTR calculation method may better reflect the impact of warfarin dose changes than the Rosendaal approach. In the ROCKET AF trial, this dose change–based approach led to a modest increase in overall mean iTTR but did not materially affect the large inter‐regional differences previously reported. Clinical Trial Registration URL: ClinicalTrials.gov. Unique identifier: NCT00403767. PMID:25736441

  19. Testing Dose-Dependent Effects of the Nectar Alkaloid Anabasine on Trypanosome Parasite Loads in Adult Bumble Bees.

    PubMed

    Anthony, Winston E; Palmer-Young, Evan C; Leonard, Anne S; Irwin, Rebecca E; Adler, Lynn S

    2015-01-01

    The impact of consuming biologically active compounds is often dose-dependent, where small quantities can be medicinal while larger doses are toxic. The consumption of plant secondary compounds can be toxic to herbivores in large doses, but can also improve survival in parasitized herbivores. In addition, recent studies have found that consuming nectar secondary compounds may decrease parasite loads in pollinators. However, the effect of compound dose on bee survival and parasite loads has not been assessed. To determine how secondary compound consumption affects survival and pathogen load in Bombus impatiens, we manipulated the presence of a common gut parasite, Crithidia bombi, and dietary concentration of anabasine, a nectar alkaloid produced by Nicotiana spp. using four concentrations naturally observed in floral nectar. We hypothesized that increased consumption of secondary compounds at concentrations found in nature would decrease survival of uninfected bees, but improve survival and ameliorate parasite loads in infected bees. We found medicinal effects of anabasine in infected bees; the high-anabasine diet decreased parasite loads and increased the probability of clearing the infection entirely. However, survival time was not affected by any level of anabasine concentration, or by interactive effects of anabasine concentration and infection. Crithidia infection reduced survival time by more than two days, but this effect was not significant. Our results support a medicinal role for anabasine at the highest concentration; moreover, we found no evidence for a survival-related cost of anabasine consumption across the concentration range found in nectar. Our results suggest that consuming anabasine at the higher levels of the natural range could reduce or clear pathogen loads without incurring costs for healthy bees.

  20. Safety and pharmacokinetics of the oral iron chelator SP-420 in β-thalassemia.

    PubMed

    Taher, Ali T; Saliba, Antoine N; Kuo, Kevin H; Giardina, Patricia J; Cohen, Alan R; Neufeld, Ellis J; Aydinok, Yesim; Kwiatkowski, Janet L; Jeglinski, Brenda I; Pietropaolo, Keith; Berk, Gregory; Viprakasit, Vip

    2017-12-01

    Our phase I, open-label, multi-center, dose-escalation study evaluated the pharmacokinetics (PK) of SP-420, a tridentate oral iron chelating agent of the desferrithiocin class, in patients with transfusion dependent β-thalassemia. SP-420 was administered as a single dose of 1.5 (n = 3), 3 (n = 3), 6 (n = 3), 12 (n = 3), and 24 (n = 6) mg/kg or as a twice-daily dose of 9 mg/kg (n = 6) over 14-28 days. There was a near dose-linear increase in the mean plasma SP-420 concentrations and in the mean values for C max and AUC 0-τ over the dose range evaluated. The median t max ranged from 0.5 to 2.25 h and was not dose dependent. The study was prematurely terminated by the sponsor due to renal adverse events (AE) including proteinuria, increase in serum creatinine, and one case of Fanconi syndrome. Other adverse effects included hypersensitivity reactions and gastrointestinal disturbances. Based on current dose administration, the renal AE observed outweighed the possible benefits from chelation therapy. However, additional studies assessing efficacy and safety of lower doses or less frequent dosing of SP-420 over longer durations with close monitoring would be necessary to better explain the findings of our study and characterize the safety of the study drug. © 2017 Wiley Periodicals, Inc.

  1. Modern dosimetric tools for 60Co irradiation at high containment laboratories

    PubMed Central

    Twardoski, Barri; Feldmann, Heinz; Bloom, Marshall E.; Ward, Joe

    2011-01-01

    Purpose To evaluate an innovative photo-fluorescent film as a routine dosimetric tool during 60Co irradiations at a high containment biological research laboratory, and to investigate whether manufacturer-provided chamber exposure rates can be used to accurately administer a prescribed dose to biological specimens. Materials and methods Photo-fluorescent, lithium fluoride film dosimeters and National Institutes of Standards and Technology (NIST) transfer dosimeters were co-located in a self-shielded 60Co irradiator and exposed to γ-radiation with doses ranging from 5–85 kGy. Film dose-response relationships were developed for varying temperatures simulating conditions present when irradiating infectious biological specimens. Dose measurement results from NIST transfer dosimeters were compared to doses predicted using manufacturer-provided irradiator chamber exposure rates. Results The film dosimeter exhibited a photo-fluorescent response signal that was consistent and nearly linear in relationship to γ-radiation exposure over a wide dose range. The dosimeter response also showed negligible effects from dose fractionization and humidity. Significant disparities existed between manufacturer-provided chamber exposure rates and actual doses administered. Conclusion This study demonstrates the merit of utilizing dosimetric tools to validate the process of exposing dangerous and exotic biological agents to γ-radiation at high containment laboratories. The film dosimeter used in this study can be utilized to eliminate potential for improperly administering γ-radiation doses. PMID:21961968

  2. Real-time dose adjustment using point-of-care platelet reactivity testing in a double-blind study of prasugrel in children with sickle cell anaemia.

    PubMed

    Jakubowski, Joseph A; Hoppe, Carolyn C; Zhou, Chunmei; Smith, Brendan E; Brown, Patricia B; Heath, Lori E; Inusa, Baba; Rees, David C; Small, David S; Gupta, Neehar; Yao, Suqin; Heeney, Matthew; Kanter, Julie

    2017-02-28

    Patients with sickle cell anaemia (SCA) have vaso-occlusive crises resulting from occlusive hypoxic-ischaemic injury. Prasugrel inhibits platelet activation and aggregation involved in SCA pathophysiology. Determining Effects of Platelet Inhibition on Vaso-Occlusive Events (DOVE) was a phase 3, double-blind, randomised, placebo-controlled trial assessing prasugrel efficacy. DOVE sought to bring patients' P2Y12 reaction unit (PRU) value within a targeted range via prasugrel dose adjustments using encrypted VerifyNow P2Y12 ® (VN-P2Y12) point-of-care testing and an interactive voice-response system (IVRS). After PRU determination, randomised patients received 0.08 mg/kg/day prasugrel or placebo. Encrypted PRUs and IVRS provided double-blind dose adjustments to achieve a defined PRU target range of 136-231; placebo patients had mock titrations. Of 341 randomised patients, 166 placebo and 160 prasugrel patients reached the fully titrated dose (FTD). Most prasugrel patients (n=104, 65 %) remained on the initial 0.08 mg/kg dose; doses escalations occurred in 23 % of patients (n=36). Mean PRUs for the pharmacodynamic population at baseline were similar in the prasugrel (273 ± 44.9) and placebo groups (273 ± 51.7), with significant reductions in PRU (p<0.001) for prasugrel patients at the FTD and at 9 months. Concomitant use of hydroxyurea did not affect platelet reactivity at any time. The majority of prasugrel patients (n=135, 84.4 %) at the FTD were within the target range of 136-231 PRUs. Mean VN-P2Y12 percentage inhibition at baseline was similar in the prasugrel (2.8  ± 5.4 %) and placebo groups (2.0 ± 4.7 %); prasugrel patients had significant increases in inhibition (p<0.001) at FTD and at 9 months. Patients with higher PRU values at baseline required higher prasugrel doses to bring PRU within the prespecified range. DOVE is the first study to successfully employ double-blind, real-time, encrypted, point-of-care platelet testing and IVRS to dose-adjust antiplatelet therapy to a targeted range of platelet inhibition.

  3. Impact of Dietary Antioxidants on Sport Performance: A Review.

    PubMed

    Braakhuis, Andrea J; Hopkins, Will G

    2015-07-01

    Many athletes supplement with antioxidants in the belief this will reduce muscle damage, immune dysfunction and fatigue, and will thus improve performance, while some evidence suggests it impairs training adaptations. Here we review the effect of a range of dietary antioxidants and their effects on sport performance, including vitamin E, quercetin, resveratrol, beetroot juice, other food-derived polyphenols, spirulina and N-acetylcysteine (NAC). Older studies suggest vitamin E improves performance at altitude, with possible harmful effects on sea-level performance. Acute intake of vitamin E is worthy of further consideration, if plasma levels can be elevated sufficiently. Quercetin has a small beneficial effect for exercise of longer duration (>100 min), but it is unclear whether this benefits athletes. Resveratrol benefits trained rodents; more research is needed in athletes. Meta-analysis of beetroot juice studies has revealed that the nitrate component of beetroot juice had a substantial but unclear effect on performance when averaged across athletes, non-athletes and modes of exercise (single dose 1.4 ± 2.0%, double dose 0.5 ± 1.9%). The effect of addition of polyphenols and other components to beetroot juice was trivial but unclear (single dose 0.4 ± 3.2%, double dose -0.5 ± 3.3%). Other food-derived polyphenols indicate a range of performance outcomes from a large improvement to moderate impairment. Limited evidence suggests spirulina enhances endurance performance. Intravenous NAC improved endurance cycling performance and reduced muscle fatigue. On the basis of vitamin E and NAC studies, acute intake of antioxidants is likely to be beneficial. However, chronic intakes of most antioxidants have a harmful effect on performance.

  4. [BIOLOGICAL EFFECTIVENESS OF FISSION SPECTRUM NEUTRONS AND PROTONS WITH ENERGIES OF 60-126 MEV DURING ACUTE AND PROLONGED IRRADIATION].

    PubMed

    Shafirkin, A V

    2015-01-01

    Neutrons of the fission spectrum are characterized by relatively high values of linear energy transfer (LET). Data about their effects on biological objects are used to evaluate the risk of delayed effects of accelerated ions within the same LET range that serve as an experimental model of the nuclei component of galactic cosmic rays (GCR). Additionally, risks of delayed consequences to cosmonaut's health and average lifetime from certain GCR fluxes and secondary neutrons can be also prognosticated. The article deals with comparative analysis of the literature on reduction of average lifespan (ALS) of animals exposed to neutron reactor spectrum, 60-126 MeV protons, and X- and γ-rays in a broad range of radiation intensity and duration. It was shown that a minimal lifespan reduction by 5% occurs due to a brief exposure to neutrons with the absorbed dose of 5 cGy, whereas same lifespan reduction due to hard X- and γ-radiation occurs after absorption of a minimal dose of 100 cGy. Therefore, according to the estimated minimal ALS reduction in mice, neutron effectiveness is 20-fold higher. Biological effectiveness of protons as regards ALS reduction is virtually equal to that of standard types of radiation. Exposure to X- and γ-radiation with decreasing daily doses, and increasing number of fractions and duration gives rise to an apparent trend toward a less dramatic ALS reduction in mice; on the contrary, exposure to neutrons of varying duration had no effect on threshold doses for the specified ALS reductions. Factors of relative biological effectiveness of neutrons reached 40.

  5. Pesticide risk assessment in free-ranging bees is weather and landscape dependent.

    PubMed

    Henry, Mickaël; Bertrand, Colette; Le Féon, Violette; Requier, Fabrice; Odoux, Jean-François; Aupinel, Pierrick; Bretagnolle, Vincent; Decourtye, Axel

    2014-07-10

    The risk assessment of plant protection products on pollinators is currently based on the evaluation of lethal doses through repeatable lethal toxicity laboratory trials. Recent advances in honeybee toxicology have, however, raised interest on assessing sublethal effects in free-ranging individuals. Here, we show that the sublethal effects of a neonicotinoid pesticide are modified in magnitude by environmental interactions specific to the landscape and time of exposure events. Field sublethal assessment is therefore context dependent and should be addressed in a temporally and spatially explicit way, especially regarding weather and landscape physiognomy. We further develop an analytical Effective Dose (ED) framework to help disentangle context-induced from treatment-induced effects and thus to alleviate uncertainty in field studies. Although the ED framework involves trials at concentrations above the expected field exposure levels, it allows to explicitly delineating the climatic and landscape contexts that should be targeted for in-depth higher tier risk assessment.

  6. Three-dimensional analysis of the respiratory interplay effect in helical tomotherapy: Baseline variations cause the greater part of dose inhomogeneities seen.

    PubMed

    Tudor, G Samuel J; Harden, Susan V; Thomas, Simon J

    2014-03-01

    Dose differences from those planned can occur due to the respiratory interplay effect on helical tomotherapy. The authors present a technique to calculate single-fraction doses in three-dimensions resulting from craniocaudal motion applied to a patient CT set. The technique is applied to phantom and patient plans using patient respiratory traces. An additional purpose of the work is to determine the contribution toward the interplay effect of different components of the respiratory trace. MATLAB code used to calculate doses to a CT dataset from a helical tomotherapy plan has been modified to permit craniocaudal motion and improved temporal resolution. Real patient traces from seven patients were applied to ten phantom plans of differing field width, modulation factor, pitch and fraction dose, and simulations made with peak-to-peak amplitudes ranging from 0 to 2.5 cm. PTV voxels near the superior or inferior limits of the PTV are excluded from the analysis. The maximum dose discrepancy compared with the static case recorded along with the proportion of voxels receiving more than 10% and 20% different from prescription dose. The analysis was repeated with the baseline variation of the respiratory trace removed, leaving the cyclic component of motion only. Radiochromic film was used on one plan-trace combination and compared with the software simulation. For one case, filtered traces were generated and used in simulations which consisted only of frequencies near to particular characteristic frequencies of the treatment delivery. Intraslice standard deviation of dose differences was used to identify potential MLC interplay, which was confirmed using nonmodulated simulations. Software calculations were also conducted for four realistic patient plans and modeling movement of a patient CT set with amplitudes informed by the observed motion of the GTV on 4DCT. The maximum magnitude of dose difference to a PTV voxel due to the interplay effect within a particular plan-trace combination for peak-to-peak amplitudes of up to 2.5 cm ranged from 4.5% to 51.6% (mean: 23.8%) of the dose delivered in the absence of respiratory motion. For cyclic motion only, the maximum dose differences in each combination ranged from 2.1% to 26.2% (mean: 9.2%). There is reasonable correspondence between an example of the phantom plan simulations and radiochromic film measurement. The filtered trace simulations revealed that frequencies close to the characteristic frequency of the jaw motion across the target were found to generate greater interplay effect than frequencies close to the gantry frequency or MLC motion. There was evidence of interplay between respiratory motion and MLC modulation, but this is small compared with the interplay between respiratory motion and jaw motion. For patient-plan simulations, dose discrepancies are seen of up to 9.0% for a patient with 0.3 cm peak-to-peak respiratory amplitude and up to 17.7% for a patient with 0.9 cm peak-to-peak amplitude. These values reduced to 1.3% and 6.5%, respectively, when only cyclic motion was considered. Software has been developed to simulate craniocaudal respiratory motion in phantom and patient plans using real patient respiratory traces. Decomposition of the traces into baseline andcyclic components reveals that the large majority of the interplay effect seen with the full trace is due to baseline variation during treatment.

  7. Placebo-controlled pilot trial testing dose titration and intravenous, intramuscular and subcutaneous routes for ketamine in depression.

    PubMed

    Loo, C K; Gálvez, V; O'Keefe, E; Mitchell, P B; Hadzi-Pavlovic, D; Leyden, J; Harper, S; Somogyi, A A; Lai, R; Weickert, C S; Glue, P

    2016-07-01

    This pilot study assessed the feasibility, efficacy and safety of an individual dose-titration approach, and of the intravenous (IV), intramuscular (IM) and subcutaneous (SC) routes for treating depression with ketamine. Fifteen treatment-refractory depressed participants received ketamine or midazolam (control treatment) in a multiple crossover, double-blind study. Ketamine was administered by IV (n = 4), IM (n = 5) or SC (n = 6) injection. Dose titration commenced at 0.1 mg/kg, increasing by 0.1 mg/kg up to 0.5 mg/kg, given in separate treatment sessions separated by ≥1 week, with one placebo control treatment randomly inserted. Mood, psychotomimetic and hemodynamic effects were assessed and plasma ketamine concentrations assayed. Twelve participants achieved response and remission criteria, achieved at doses as low as 0.1 mg/kg. All three routes of administration resulted in comparable antidepressant effects. Fewest adverse effects were noted with the SC route. Antidepressant response, adverse effects and ketamine concentrations were dose-related. Antidepressant response occurred at a range of doses and at <0.5 mg/kg. The dose-titration approach is a practical method for optimizing the efficacy - side-effects trade-off on an individual patient basis. This pilot study provides preliminary evidence for SC injection as a practical, feasible and efficacious treatment approach. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. The safety of antituberculosis medications during breastfeeding.

    PubMed

    Tran, J H; Montakantikul, P

    1998-12-01

    Most antituberculosis drugs appear to be safe for use with breastfeeding. These agents are excreted in breast milk at relatively small concentrations. No adverse effects have been reported to date. The percentages of the therapeutic dose of antituberculosis agents that potentially may be delivered to the nursing infants range from 0.05% to 28%. Currently isoniazid, rifampin, ethambutol, streptomycin (first-line agents), kanamycin and cycloserine (second-line agents) are the only agents considered by the AAP to be compatible with breastfeeding. Unfortunately, there are still no clear data on the safety of pyrazinamide, ethionamide, and capreomycin during breastfeeding. If the mother chooses to breastfeed, it may be prudent to examine the infant for signs and symptoms of toxicity. In infants requiring treatment with antituberculosis agents, it is important to use therapeutic doses since drug concentrations in breast milk are not adequate as effective therapy for treatment or prevention. However, dosing at the lower end of the therapeutic range should be prescribed (i.e., 10 mg/kg/day of isoniazid) to decrease the risk of toxicity.

  9. Gamma irradiation affects the total phenol, anthocyanin and antioxidant properties in three different persian pistachio nuts.

    PubMed

    Akbari, Mohammad; Farajpour, Mostafa; Aalifar, Mostafa; Sadat Hosseini, Mohammad

    2018-02-01

    The effects of gamma irradiation (GR) on total phenol, anthocyanin and antioxidant activity were investigated in three different Persian pistachio nuts at doses of 0, 1, 2 and 4 kGy. The antioxidant activity, as determined by FRAP and DPPH methods, revealed a significant increase in the 1-2 kGy dose range. Total phenol content (TPC) revealed a similar pattern or increase in this range. However, when radiation was increased to 4 kGy, TPC in all genotypes decreased. A radiation dose of 1 kGy had no significant effect on anthocyanin content of Kale-Ghouchi (K) and Akbari (A) genotypes, while it significantly increased the anthocyanin content in the Ghazvini (G) genotype. In addition, increasing the radiation to 4 kGy significantly increased the anthocyanin content of K and G genotypes. To conclude, irradiation could increase the phenolic content, anthocyanin and antioxidant activity of pistachio nuts.

  10. Reconstruction of paediatric organ doses from axial CT scans performed in the 1990s - range of doses as input to uncertainty estimates.

    PubMed

    Olerud, Hilde M; Toft, Benthe; Flatabø, Silje; Jahnen, Andreas; Lee, Choonsik; Thierry-Chef, Isabelle

    2016-09-01

    To assess the range of doses in paediatric CT scans conducted in the 1990s in Norway as input to an international epidemiology study: the EPI-CT study, http://epi-ct.iarc.fr/ . National Cancer Institute dosimetry system for Computed Tomography (NCICT) program based on pre-calculated organ dose conversion coefficients was used to convert CT Dose Index to organ doses in paediatric CT in the 1990s. Protocols reported from local hospitals in a previous Norwegian CT survey were used as input, presuming these were used without optimization for paediatric patients. Large variations in doses between different scanner models and local scan parameter settings are demonstrated. Small children will receive a factor of 2-3 times higher doses compared with adults if the protocols are not optimized for them. For common CT examinations, the doses to the active bone marrow, breast tissue and brain may have exceeded 30 mGy, 60 mGy and 100 mGy respectively, for the youngest children in the 1990s. The doses children received from non-optimised CT examinations during the 1990s are of such magnitude that they may provide statistically significant effects in the EPI-CT study, but probably do not reflect current practice. • Some organ doses from paediatric CT in the 1990s may have exceeded 100 mGy. • Small children may have received doses 2-3 times higher compared with adults. • Different scanner models varied by a factor of 2-3 in dose to patients. • Different local scan parameter settings gave dose variations of a factor 2-3. • Modern CTs and age-adjusted protocols will give much lower paediatric doses.

  11. Correlation of radiation dose and heart rate in dual-source computed tomography coronary angiography.

    PubMed

    Laspas, Fotios; Tsantioti, Dimitra; Roussakis, Arkadios; Kritikos, Nikolaos; Efthimiadou, Roxani; Kehagias, Dimitrios; Andreou, John

    2011-04-01

    Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.

  12. Cardiac-Specific Conversion Factors to Estimate Radiation Effective Dose From Dose-Length Product in Computed Tomography.

    PubMed

    Trattner, Sigal; Halliburton, Sandra; Thompson, Carla M; Xu, Yanping; Chelliah, Anjali; Jambawalikar, Sachin R; Peng, Boyu; Peters, M Robert; Jacobs, Jill E; Ghesani, Munir; Jang, James J; Al-Khalidi, Hussein; Einstein, Andrew J

    2018-01-01

    This study sought to determine updated conversion factors (k-factors) that would enable accurate estimation of radiation effective dose (ED) for coronary computed tomography angiography (CTA) and calcium scoring performed on 12 contemporary scanner models and current clinical cardiac protocols and to compare these methods to the standard chest k-factor of 0.014 mSv·mGy -1 cm -1 . Accurate estimation of ED from cardiac CT scans is essential to meaningfully compare the benefits and risks of different cardiac imaging strategies and optimize test and protocol selection. Presently, ED from cardiac CT is generally estimated by multiplying a scanner-reported parameter, the dose-length product, by a k-factor which was determined for noncardiac chest CT, using single-slice scanners and a superseded definition of ED. Metal-oxide-semiconductor field-effect transistor radiation detectors were positioned in organs of anthropomorphic phantoms, which were scanned using all cardiac protocols, 120 clinical protocols in total, on 12 CT scanners representing the spectrum of scanners from 5 manufacturers (GE, Hitachi, Philips, Siemens, Toshiba). Organ doses were determined for each protocol, and ED was calculated as defined in International Commission on Radiological Protection Publication 103. Effective doses and scanner-reported dose-length products were used to determine k-factors for each scanner model and protocol. k-Factors averaged 0.026 mSv·mGy -1 cm -1 (95% confidence interval: 0.0258 to 0.0266) and ranged between 0.020 and 0.035 mSv·mGy -1 cm -1 . The standard chest k-factor underestimates ED by an average of 46%, ranging from 30% to 60%, depending on scanner, mode, and tube potential. Factors were higher for prospective axial versus retrospective helical scan modes, calcium scoring versus coronary CTA, and higher (100 to 120 kV) versus lower (80 kV) tube potential and varied among scanner models (range of average k-factors: 0.0229 to 0.0277 mSv·mGy -1 cm -1 ). Cardiac k-factors for all scanners and protocols are considerably higher than the k-factor currently used to estimate ED of cardiac CT studies, suggesting that radiation doses from cardiac CT have been significantly and systematically underestimated. Using cardiac-specific factors can more accurately inform the benefit-risk calculus of cardiac-imaging strategies. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  13. Effects of neutron irradiation on optical and chemical properties of CR-39: Potential application in neutron dosimetry.

    PubMed

    Sahoo, G S; Paul, S; Tripathy, S P; Sharma, S C; Jena, S; Rout, S; Joshi, D S; Bandyopadhyay, T

    2014-12-01

    Effects of high-dose neutron irradiation on chemical and optical properties of CR-39 were studied using FTIR (Fourier Transform Infrared) and UV-vis (Ultraviolet-Visible) spectroscopy. The primary goal was to find a correlation between the neutron dose and the corresponding changes in the optical and chemical properties of CR-39 resulted from the neutron irradiation. The neutrons were produced by bombarding a thick Be target with 22-MeV protons. In the FTIR spectra, prominent absorbance peaks were observed at 1735cm(-1) (C=O stretching), 1230cm(-1)(C-O-C stretching), and 783cm(-1)(=C-H bending), the intensities of which decreased with increasing neutron dose. The optical absorbance in the visible range increased linearly with the neutron dose. Empirical relations were established to estimate neutron doses from these optical properties. This technique is particularly useful in measuring high doses, where track analysis with an optical microscope is difficult because of track overlapping. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Effects of beam interruption time on tumor control probability in single-fractionated carbon-ion radiotherapy for non-small cell lung cancer

    NASA Astrophysics Data System (ADS)

    Inaniwa, T.; Kanematsu, N.; Suzuki, M.; Hawkins, R. B.

    2015-05-01

    Carbon-ion radiotherapy treatment plans are designed on the assumption that the beams are delivered instantaneously, irrespective of actual dose-delivery time structure in a treatment session. As the beam lines are fixed in the vertical and horizontal directions at our facility, beam delivery is interrupted in multi-field treatment due to the necessity of patient repositioning within the fields. Single-fractionated treatment for non-small cell lung cancer (NSCLC) is such a case, in which four treatment fields in multiple directions are delivered in one session with patient repositioning during the session. The purpose of this study was to investigate the effects of the period of dose delivery, including interruptions due to patient repositioning, on tumor control probability (TCP) of NSCLC. All clinical doses were weighted by relative biological effectiveness (RBE) evaluated for instantaneous irradiation. The rate equations defined in the microdosimetric kinetic model (MKM) for primary lesions induced in DNA were applied to the single-fractionated treatment of NSCLC. Treatment plans were made for an NSCLC case for various prescribed doses ranging from 25 to 50 Gy (RBE), on the assumption of instantaneous beam delivery. These plans were recalculated by varying the interruption time τ ranging from 0 to 120 min between the second and third fields for continuous irradiations of 3 min per field based on the MKM. The curative doses that would result in a TCP of 90% were deduced for the respective interruption times. The curative dose was 34.5 Gy (RBE) for instantaneous irradiation and 36.6 Gy (RBE), 39.2 Gy (RBE), 41.2 Gy (RBE), 43.3 Gy (RBE) and 44.4 Gy (RBE) for τ = 0 min, 15 min, 30 min, 60 min and 120 min, respectively. The realistic biological effectiveness of therapeutic carbon-ion beam decreased with increasing interruption time. These data suggest that the curative dose can increase by 20% or more compared to the planned dose if the interruption time extends to 30 min or longer. These effects should be considered in carbon-ion radiotherapy treatment planning if a longer dose-delivery procedure time is anticipated.

  15. Accounting for neutron exposure in the Japanese atomic bomb survivors.

    PubMed

    Cullings, Harry M; Pierce, Donald A; Kellerer, Albrecht M

    2014-12-01

    The Japanese atomic bomb survivors that were directly exposed to both γ rays and neutrons have been followed by the Radiation Effects Research Foundation (RERF). The estimation of the γ-ray risks requires some adjustment for the greater biological effect of the neutrons per unit dose. Because the small neutron doses and the predominant γ-ray doses are highly correlated, the neutron relative biological effectiveness (RBE) cannot be reliably estimated from the survivors' data and information from radiobiology must be invoked. As data became available on neutron doses, RERF has used a constant neutron RBE value of 10, even though radiobiological studies indicate that the RBE values appear to have considerably larger values at low doses. The approximation RBE = 10 assumes that if the RBE is variable it takes roughly this value in the range of total dose most relevant for linear risk estimation, namely about 1 Gy. We consider some possible RBE functions to explain the correct use and the impact of a dose-dependent RBE. However, we do not advocate any particular choice or even that a variable RBE be employed. Rather we show that the assumed neutron RBE, within a wide range of choices, is far less important to the outcome of risk assessment of the RERF data than generally believed. Some of these misperceptions have been related to the consideration of variable RBE functions, and without due attention to the fact that in the case of the A-bomb survivors' data, the mixed field of neutrons and γ rays must be considered. Therefore, the RBE value of neutrons is much lower than the RBE in pure neutron fields that are used in radiobiological experiments. Thus, applying the pure neutron field RBE to the mixed-field A-bomb radiation can lead to an overestimation of the actual neutron RBE for moderate total dose levels of 1 Gy by a factor of more than four. While in a pure neutron exposure the RBE depends on the neutron dose, in the mixed field it depends on both components of exposure, and in particular, we show that in the RERF setting the RBE depends mainly on the accompanying γ-ray dose.

  16. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013.

    PubMed

    Taylor, Carolyn W; Wang, Zhe; Macaulay, Elizabeth; Jagsi, Reshma; Duane, Frances; Darby, Sarah C

    2015-11-15

    Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this "mean heart dose." In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28 countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Effective DQE (eDQE) and dose to optimize radiographic technical parameters: a survey of pediatric chest X-ray examinations in Korea.

    PubMed

    Park, Hye-Suk; Kim, Ye-Seul; Park, Ok-Seob; Kim, Sang-Tae; Jeon, Chang-Woo; Kim, Hee-Joung

    2014-04-01

    The purpose of this study was to investigate the effect of various technical parameters for dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE). For tube voltages ranging from 40 to 90 kV in 10 kV increments at the focus-to-detector distance (FDD) of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at same effective dose. The eDQE was considerably higher without the use of the grid on equivalent effective dose. This indicates that the reduction of scatter radiation did not compensate for the loss of absorbed effective photons in the grid. The eDQE increased with increasing FDD because of the greater effective modulation transfer function (eMTF) with lower focal spot blurring. However, most of the major hospitals in Korea employed a short FDD of 100 cm with the grid. The entrance surface air kerma values for the hospitals of this survey exceeded the Korean reference level of 100 μGy. The different reference levels might be appropriate for the same examination conducted on children of different ages. Also, it is necessary to refine the technical parameters to perform pediatric chest examinations.

  18. Potent aquaretic agent. A novel nonpeptide selective vasopressin 2 antagonist (OPC-31260) in men.

    PubMed Central

    Ohnishi, A; Orita, Y; Okahara, R; Fujihara, H; Inoue, T; Yamamura, Y; Yabuuchi, Y; Tanaka, T

    1993-01-01

    Solute-free water diuretics (aquaretics) by antagonizing hydrosmotic vasopressin receptors (V2) may be useful in treating water-retaining diseases. The effects of intravenous administration of a newly developed nonpeptide, selective V2 antagonist, OPC-31260, at doses ranging from 0.017 to 1.0 mg/kg to groups of healthy, normally hydrated men were compared with those of 0.33 mg/kg furosemide and placebo. OPC-31260 increased the hypotonic urine volume dose dependently for the first 4 h, while furosemide induced sodium diuresis for 2 h. The absolute increase in the cumulative response in the urine to the highest doses of OPC-31260 was not significantly different from that to furosemide. The higher doses of OPC-31260 rapidly lowered urine osmolality for 2 h, particularly between minutes 15 and 45 (e.g., 1.0-mg/kg dose: 63 +/- 2 mOsm/kg in urine collected between minutes 30 and 45). In a marked hypotonic diuresis, mean free water clearance of the 4-h urine increased dose proportionally into the positive range, reaching 1.80 +/- 0.21 ml/min at 1.0 mg/kg. Whereas furosemide induced marked Na and K diuresis, OPC-31260 increased urinary Na excretion only slightly. At 4 h, 0.75 and 1.0 mg/kg of OPC-31260 almost doubled the plasma arginine vasopressin; and the higher doses increased plasma osmolality and plasma Na slightly, but did not alter plasma K, blood pressure, or heart rate. OPC-31260 thus safely induced a potent aquaretic effect in men. Images PMID:8254021

  19. Cancer and non-cancer brain and eye effects of chronic low-dose ionizing radiation exposure

    PubMed Central

    2012-01-01

    Background According to a fundamental law of radiobiology (“Law of Bergonié and Tribondeau”, 1906), the brain is a paradigm of a highly differentiated organ with low mitotic activity, and is thus radio-resistant. This assumption has been challenged by recent evidence discussed in the present review. Results Ionizing radiation is an established environmental cause of brain cancer. Although direct evidence is lacking in contemporary fluoroscopy due to obvious sample size limitation, limited follow-up time and lack of focused research, anecdotal reports of clusters have appeared in the literature, raising the suspicion that brain cancer may be a professional disease of interventional cardiologists. In addition, although terminally differentiated neurons have reduced or mild proliferative capacity, and are therefore not regarded as critical radiation targets, adult neurogenesis occurs in the dentate gyrus of the hippocampus and the olfactory bulb, and is important for mood, learning/memory and normal olfactory function, whose impairment is a recognized early biomarker of neurodegenerative diseases. The head doses involved in radiotherapy are high, usually above 2 Sv, whereas the low-dose range of professional exposure typically involves lifetime cumulative whole-body exposure in the low-dose range of < 200 mSv, but with head exposure which may (in absence of protection) arrive at a head equivalent dose of 1 to 3 Sv after a professional lifetime (corresponding to a brain equivalent dose around 500 mSv). Conclusions At this point, a systematic assessment of brain (cancer and non-cancer) effects of chronic low-dose radiation exposure in interventional cardiologists and staff is needed. PMID:22540409

  20. External beam radiotherapy for palliation of painful bone metastases: pooled data bioeffect dose response analysis of dose fractionation

    NASA Astrophysics Data System (ADS)

    Naveen, T.; Supe, Sanjay S.; Ganesh, K. M.; Samuel, Jacob

    2009-01-01

    Bone metastases develop in up to 70% of newly diagnosed cancer patients and result in immobility, anxiety, and depression, severely diminishing the patients quality of life. Radiotherapy is a frequently used modality for bone metastasis and has been shown to be effective in reducing metastatic bone pain and in some instances, causing tumor shrinkage or growth inhibition. There is controversy surrounding the optimal fractionation schedule and total dose of external beam radiotherapy, despite many randomized trials and overviews addressing the issue. This study was undertaken to apply BED to clinical fractionation data of radiotherapeutic management of bone metastases in order to arrive at optimum BED values for acceptable level of response rate. A computerised literature search was conducted to identify all prospective clinical studies that addressed the issue of fractionation for the treatment of bone metastasis. The results of these studies were pooled together to form the database for the analysis. A total of 4111 number of patients received radiation dose ranging from 4 to 40.5 Gy in 1 to 15 fractions with dose per fraction ranging from 2 to 10 Gy. Single fraction treatments were delivered in 2013 patients and the dose varied from 4 to 10 Gy. Multifraction treatments were delivered in 2098 patients and the dose varied from 15 to 40.5 Gy. The biological effective dose (BED) was evaluated for each fractionation schedule using the linear quadratic model and an α/β value of 10 Gy. Response rate increased significantly beyond a BED value of 14.4 Gy (p < 0.01). Based on our analysis and indications from the literature about higher retreatment and fracture rate of single fraction treatments, minimum BED value of 14.4 Gy is recommended.

  1. The effects of a 5-HT2 receptor antagonist (ICI 169,369) on changes in waking EEG, pupillary responses and state of arousal in human volunteers.

    PubMed Central

    Millson, D S; Haworth, S J; Rushton, A; Wilkinson, D; Hobson, S; Harry, J

    1991-01-01

    1. ICI 169,369 (2-(2-dimethylamino ethylthio)-3-phenyl quinoline) is a potent selective competitive antagonist of the 5-HT2 receptor in animal models. Effects of ICI 169,369 as single oral doses (80 and 120 mg) separated by 1 week, on the power spectrum of waking EEG, dark adapted pupil responses and sedation score, were studied in a double-blind, placebo controlled, randomised cross over within subject comparison, in six healthy male volunteers. 2. Pupillary responses were measured using a portable infrared pupillometer following 15 min dark adaptation, assessing resting vertical pupil diameter (RPD), light constricted diameter (MPD) and recovered final diameter (FPD) at the end of a 3 s measurement cycle. 3. Both doses of ICI 169,369 produced a mean 36% (range 10-54%) decrease in log 10 power of the waking EEG alpha activity with eyes closed (P less than 0.02), and mean 38% (range 2-86%) increase in theta activity at 2 h compared with placebo. 4. Both 80 and 120 mg doses of ICI 169,369 reduced RPD by approximately 30% from a predose value of 6.25 mm (+/- 0.87; 95% CI) and from placebo values 6.41 mm (+/- 1.06) and 7.48 mm (+/- 1.49) at 3 and 5 h after dosing. MPD was reduced by 50% with the 120 mg dose at 5 h after dosing (placebo 5.2 mm; ICI 169,369 2.7 mm; P less than 0.05). FPD was significantly reduced (P less than 0.01) by both doses at 3 h after dosing.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:1958438

  2. Comparison of patient specific dose metrics between chest radiography, tomosynthesis, and CT for adult patients of wide ranging body habitus

    PubMed Central

    Zhang, Yakun; Li, Xiang; Segars, W. Paul; Samei, Ehsan

    2014-01-01

    Purpose: Given the radiation concerns inherent to the x-ray modalities, accurately estimating the radiation doses that patients receive during different imaging modalities is crucial. This study estimated organ doses, effective doses, and risk indices for the three clinical chest x-ray imaging techniques (chest radiography, tomosynthesis, and CT) using 59 anatomically variable voxelized phantoms and Monte Carlo simulation methods. Methods: A total of 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms were used in this study. Organ doses and effective doses were estimated for a clinical radiography system with the capability of conducting chest radiography and tomosynthesis (Definium 8000, VolumeRAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). A Monte Carlo dose simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain) was used to mimic these two clinical systems. The Duke University (Durham, NC) technique charts were used to determine the clinical techniques for the radiographic modalities. An exponential relationship between CTDIvol and patient diameter was used to determine the absolute dose values for CT. The simulations of the two clinical systems compute organ and tissue doses, which were then used to calculate effective dose and risk index. The calculation of the two dose metrics used the tissue weighting factors from ICRP Publication 103 and BEIR VII report. Results: The average effective dose of the chest posteroanterior examination was found to be 0.04 mSv, which was 1.3% that of the chest CT examination. The average effective dose of the chest tomosynthesis examination was found to be about ten times that of the chest posteroanterior examination and about 12% that of the chest CT examination. With increasing patient average chest diameter, both the effective dose and risk index for CT increased considerably in an exponential fashion, while these two dose metrics only increased slightly for radiographic modalities and for chest tomosynthesis. Effective and organ doses normalized to mAs all illustrated an exponential decrease with increasing patient size. As a surface organ, breast doses had less correlation with body size than that of lungs or liver. Conclusions: Patient body size has a much greater impact on radiation dose of chest CT examinations than chest radiography and tomosynthesis. The size of a patient should be considered when choosing the best thoracic imaging modality. PMID:24506654

  3. An example of problems in dose reconstruction from doses formed by electromagnetic irradiation by different energy sources.

    PubMed

    Kirillov, Vladimir; Kuchuro, Joseph; Tolstik, Sergey; Leonova, Tatyana

    2010-02-01

    Dose reconstruction for citizens of Belarus affected by the Chernobyl accident showed an unexpectedly wide range of doses. Using the EPR tooth enamel dosimetry method, it has been demonstrated that when the tooth enamel dose was formed due to x-rays with effective energy of 34 keV and the additional irradiation of enamel samples was performed by gamma radiation with mean energy of 1,250 keV, it led to a considerable increase in the reconstructed absorbed dose as compared with the applied. In the case when the dose was formed due to gamma radiation and the additional irradiation was performed by x-rays, it led to a considerable decrease in the reconstructed dose as compared with the applied. When the dose formation and the additional irradiation were carried out from external sources of electromagnetic radiation of equal energy, the reconstructed dose value was close to that of the applied. The obtained data show that for adequate reconstruction of individual absorbed doses by the EPR tooth enamel spectra, it is necessary to take into account the contribution from diagnostic x-ray examination of the teeth, jaw, and skull of some individuals who were exposed to a combined effect of the external gamma radiation and x-rays.

  4. Measurement of relative depth-dose distribution in radiochromic film dosimeters irradiated with 43-70 keV electron beam for industrial application

    NASA Astrophysics Data System (ADS)

    Matsui, Shinjiro; Hattori, Takeaki; Nonaka, Takashi; Watanabe, Yuki; Morita, Ippei; Kondo, Junichi; Ishikawa, Masayoshi; Mori, Yoshitaka

    2018-05-01

    The relative dose in a layer, which is thinner than the thickness of the dosimeter is evaluated using simulated depth-dose distributions, and the measured responses of dosimeters with acceleration voltages from 43 to 70 kV, via ultra-low-energy electron beam (ULEB) irradiation. By stacking thin film dosimeters, we confirmed that the simulated depth-dose distributions coincided with the measured depth-dose curve within the measurement uncertainty (k = 2). Using the measurement dose of the 47 μm dosimeter and the simulated depth-dose distribution, the dose of 11 μm dosimeters in the surface was evaluated within the measurement uncertainty (k = 2). We also verified the effectiveness of this method for a thinner layer by changing the acceleration voltage of the irradiation source. We evaluated the relative dose for an adjusted depth of energy deposition from 4.4 μm to 22.8 μm. As a result, this method was found to be effective for a thickness, which is less than the thickness of the dosimeter. When irradiation conditions are well known with accuracy, using the confirmed relative depth-dose distributions across any dosimeter thickness range, a dose evaluation, in several μm steps will possibly improve the design of industrial ULEB processes.

  5. Effects of gamma radiation on total phenolics, trypsin and tannin inhibitors in soybean grains

    NASA Astrophysics Data System (ADS)

    de Toledo, T. C. F.; Canniatti-Brazaca, S. G.; Arthur, V.; Piedade, S. M. S.

    2007-10-01

    The objective was determining possible radiation-induced alterations (with doses of 2, 4 and 8 kGy) in raw or cooked grains from five soybean cultivars through the analysis of some antinutrient. Total phenolic ranged from 2.46 to 10.83 mg/g, the trypsin inhibited from 18.19 to 71.64 UTI/g and tannins from 0.01 to 0.39 mg/g. All the antinutrient studied underwent reduction with increases in the doses and cooking process was effective too.

  6. The evolution of spinal/epidural neostigmine in clinical application: Thoughts after two decades

    PubMed Central

    Lauretti, Gabriela Rocha

    2015-01-01

    Since the first clinical application of analgesia following spinal anticholinesterase by 1940's, several clinical double-blind studies have been conducted to date, where intrathecal doses of neostigmine in humans ranged from 750 to 1 μg, due to side-effects. Conversely, epidural neostigmine has been evaluated in proportionally higher doses and represents an alternative, but still deserves more investigation concerning both acute and chronic pain, as it seems devoid of important side-effects. PMID:25558203

  7. Thyroid remnant ablation with 1110MBq of 131I in outpatients: measurement of effective dose to household members and establishment of safety precautions.

    PubMed

    Yoshimura, M; Tsutsui, H; Ikeda, N; Koizumi, K

    2013-03-01

    The aim of this study was to establish and confirm the safety of administering 1110MBq of 131I to outpatients. Total radiation exposure from patients to household members was hypothesized from the measured dose rate at 1 m when the patient is released. Actually we also measured the effective dose to household members who assisted outpatients during the first 7 days after the administration of 131I by personal dosimeter. A list of radiation safety precautions is given to the patient and household members. Behavioral reports about the distances and times of close contact throughout the 7 days are requested of each household member. The effective dose measured using the personal dosimeter to all household members employing several safety precautions was confirmed to be lower than the hypothesized dose calculated using our formula. And the mean whole-body effective dose rate over the 7 days in household members was 0.05±0.08 (range, 0.05 to 0.43) mSv, which specify that radiation exposure to household members of the outpatients who have just received ablative radiation therapy must be below 5.0 mSv/event. Remnant thyroid ablation with 1110MBq for outpatients showed that the radiation doses to household members were within the recommended constraint dose according to several safety precautions. The method of returning home after remnant thyroid ablation is thought to be the most important factor that determines the effective dose to household members of outpatients.

  8. Independent dose verification system with Monte Carlo simulations using TOPAS for passive scattering proton therapy at the National Cancer Center in Korea

    NASA Astrophysics Data System (ADS)

    Shin, Wook-Geun; Testa, Mauro; Kim, Hak Soo; Jeong, Jong Hwi; Byeong Lee, Se; Kim, Yeon-Joo; Min, Chul Hee

    2017-10-01

    For the independent validation of treatment plans, we developed a fully automated Monte Carlo (MC)-based patient dose calculation system with the tool for particle simulation (TOPAS) and proton therapy machine installed at the National Cancer Center in Korea to enable routine and automatic dose recalculation for each patient. The proton beam nozzle was modeled with TOPAS to simulate the therapeutic beam, and MC commissioning was performed by comparing percent depth dose with the measurement. The beam set-up based on the prescribed beam range and modulation width was automated by modifying the vendor-specific method. The CT phantom was modeled based on the DICOM CT files with TOPAS-built-in function, and an in-house-developed C++ code directly imports the CT files for positioning the CT phantom, RT-plan file for simulating the treatment plan, and RT-structure file for applying the Hounsfield unit (HU) assignment, respectively. The developed system was validated by comparing the dose distributions with those calculated by the treatment planning system (TPS) for a lung phantom and two patient cases of abdomen and internal mammary node. The results of the beam commissioning were in good agreement of up to 0.8 mm2 g-1 for B8 option in both of the beam range and the modulation width of the spread-out Bragg peaks. The beam set-up technique can predict the range and modulation width with an accuracy of 0.06% and 0.51%, respectively, with respect to the prescribed range and modulation in arbitrary points of B5 option (128.3, 132.0, and 141.2 mm2 g-1 of range). The dose distributions showed higher than 99% passing rate for the 3D gamma index (3 mm distance to agreement and 3% dose difference) between the MC simulations and the clinical TPS in the target volume. However, in the normal tissues, less favorable agreements were obtained for the radiation treatment planning with the lung phantom and internal mammary node cases. The discrepancies might come from the limitations of the clinical TPS, which is the inaccurate dose calculation algorithm for the scattering effect, in the range compensator and inhomogeneous material. Moreover, the steep slope of the compensator, conversion of the HU values to the human phantom, and the dose calculation algorithm for the HU assignment also could be reasons of the discrepancies. The current study could be used for the independent dose validation of treatment plans including high inhomogeneities, the steep compensator, and riskiness such as lung, head & neck cases. According to the treatment policy, the dose discrepancies predicted with MC could be used for the acceptance decision of the original treatment plan.

  9. A pharmacometric case study regarding the sensitivity of structural model parameter estimation to error in patient reported dosing times.

    PubMed

    Knights, Jonathan; Rohatagi, Shashank

    2015-12-01

    Although there is a body of literature focused on minimizing the effect of dosing inaccuracies on pharmacokinetic (PK) parameter estimation, most of the work centers on missing doses. No attempt has been made to specifically characterize the effect of error in reported dosing times. Additionally, existing work has largely dealt with cases in which the compound of interest is dosed at an interval no less than its terminal half-life. This work provides a case study investigating how error in patient reported dosing times might affect the accuracy of structural model parameter estimation under sparse sampling conditions when the dosing interval is less than the terminal half-life of the compound, and the underlying kinetics are monoexponential. Additional effects due to noncompliance with dosing events are not explored and it is assumed that the structural model and reasonable initial estimates of the model parameters are known. Under the conditions of our simulations, with structural model CV % ranging from ~20 to 60 %, parameter estimation inaccuracy derived from error in reported dosing times was largely controlled around 10 % on average. Given that no observed dosing was included in the design and sparse sampling was utilized, we believe these error results represent a practical ceiling given the variability and parameter estimates for the one-compartment model. The findings suggest additional investigations may be of interest and are noteworthy given the inability of current PK software platforms to accommodate error in dosing times.

  10. Effect of low dose and moderate dose gamma irradiation on the mechanical properties of bone and soft tissue allografts.

    PubMed

    Balsly, Colleen R; Cotter, Andrew T; Williams, Lisa A; Gaskins, Barton D; Moore, Mark A; Wolfinbarger, Lloyd

    2008-12-01

    The increased use of allograft tissue for musculoskeletal repair has brought more focus to the safety of allogenic tissue and the efficacy of various sterilization techniques. Gamma irradiation is an effective method for providing terminal sterilization to biological tissue, but it is also reported to have deleterious effects on tissue mechanics in a dose-dependent manner. At irradiation ranges up to 25 kGy, a clear relationship between mechanical strength and dose has yet to be established. The aim of this study was to investigate the mechanical properties of bone and soft tissue allografts, irradiated on dry ice at a low absorbed dose (18.3-21.8 kGy) and a moderate absorbed dose (24.0-28.5 kGy), using conventional compressive and tensile testing, respectively. Bone grafts consisted of Cloward dowels and iliac crest wedges, while soft tissue grafts consisted of patellar tendons, anterior tibialis tendons, semitendinosus tendons, and fascia lata. There were no statistical differences in mechanical strength or modulus of elasticity for any graft irradiated at a low absorbed dose, compared to control groups. Also, bone allografts and two soft tissue allografts (anterior tibialis and semitendinosus tendon) that were irradiated at a moderate dose demonstrated similar strength and modulus of elasticity values to control groups. The results of this study support the use of low dose and moderate dose gamma irradiation of bone grafts. For soft tissue grafts, the results support the use of low dose irradiation.

  11. European Academy of Allergy and Clinical Immunology task force report on 'dose-response relationship in allergen-specific immunotherapy'.

    PubMed

    Calderón, M A; Larenas, D; Kleine-Tebbe, J; Jacobsen, L; Passalacqua, G; Eng, P A; Varga, E M; Valovirta, E; Moreno, C; Malling, H J; Alvarez-Cuesta, E; Durham, S; Demoly, P

    2011-10-01

    For a century, allergen-specific immunotherapy (SIT) has proven to be an effective treatment for allergic rhinitis, asthma, and insect sting allergy. However, as allergen doses are frequently adapted to the individual patient, there are few data on dose-response relationship in SIT. Allergen products for SIT are being increasingly required to conform to regulatory requirements for human medicines, which include the need to demonstrate dose-dependent effects. This report, produced by a Task Force of the EAACI Immunotherapy Interest Group, evaluates the currently available data on dose-response relationships in SIT and aims to provide recommendations for the design of future studies. Fifteen dose-ranging studies fulfilled the inclusion criteria and twelve reported a dose-response relationship for clinical efficacy. Several studies also reported a dose-response relationship for immunological and safety endpoints. Due to the use of different reference materials and methodologies for the determination of allergen content, variations in study design, and choice of endpoints, no comparisons could be made between studies and, as a consequence, no general dosing recommendations can be made. Despite recently introduced guidelines on the standardization of allergen preparations and study design, the Task Force identified a need for universally accepted standards for the measurement of allergen content in SIT preparations, dosing protocols, and selection of clinical endpoints to enable dose-response effects to be compared across studies. © 2011 John Wiley & Sons A/S.

  12. A prospective study on radiation-induced changes in hearing function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Herrmann, Franziska; Doerr, Wolfgang; Experimental Center, Medical Faculty Carl Gustav Carus, University of Technology-Dresden, Dresden

    Purpose: To quantitate changes in hearing function after radiotherapy for head-and-neck tumors. Methods and Materials: At the Department of Radiotherapy and Radiation Oncology, 32 patients were irradiated for head-and-neck tumors. Three-dimensional treatment planning was applied. Total tumor doses were 30.0-77.6 Gy, local doses to the inner ear (n = 64) ranged from 1.7 to 64.3 Gy. Audiometry was performed before the onset of radiotherapy (RT), at a tumor dose of 40 Gy or at the end of palliative treatment, at the end of curative RT, and 2-6 months post-RT. Assays applied were frequency-specific threshold measurements for air and bone conduction,more » measurements according to Weber and Rinne, tympanometry and assessment of the stapedius reflex. Results: Age and prior disease significantly decreased, whereas previous or concurrent alcohol consumption significantly increased hearing ability. A significant reduction in hearing ability during RT was found for high frequencies (at 40 Gy) and low frequencies (at end of RT), which persisted after RT. No differences were observed for air or bone conduction. None of the other assays displayed time- or dose-dependent changes. Dose-effect analyses revealed an ED50 (dose at which a 50% incidence is expected) for significant changes in hearing thresholds (15 dB) in the range of 20-25 Gy, with large confidence limits. Conclusions: Radiation effects on hearing ability were confined to threshold audiogram values, which started during the treatment without reversibility during 6 months postradiotherapy.« less

  13. Characteristics of fiber-optic radiation sensor for passive scattering proton beams

    NASA Astrophysics Data System (ADS)

    Son, J.; Kim, M.; Jeong, J.; Lim, Y.; Lee, S. B.; Shin, D.; Yoon, M.

    2017-11-01

    The aims of this study were to investigate the characteristics of a fiber-optic radiation sensor (FORS) that detects the fluorescence light produced by proton beam and to verify its effectiveness in proton therapy quality assurance (QA). Various characteristics of the FORS were investigated, such as the linearity of its relationships to the sensitive length of fiber for the proton beams of intermediate ranges (165.46 and 178.37 MeV) and to the measured dose, as well as its dose rate dependence. In addition, patient specific precription dose QA was conducted for five patients actually undergoing proton therapy and the results were compared with the doses measured using an ion chamber. The results show that the signal of the FORS is linearly related to the sensitive length of fiber and to the irradiated dose in the range from 1 to 500 cGy. The QA results obtained using the FORS system showed good agreement with the corresponding ion chamber results, with an average difference of 0.40% and a standard deviation of 0.35%. The FORS was dose-rate independent for proton currents up to 5 Gy/min. The profiles of various proton beams obtained using an array of FORS, which were measured as an application of the developed dosimetric system, closely agreed with the profiles acquired using EBT3 film. In summary, the experimental results of FORS demonstrated its effectiveness for use in various proton therapy QA tests.

  14. Comparison of effects produced by nicotine and the α4β2-selective agonist 5-I-A-85380 on intracranial self-stimulation in rats.

    PubMed

    Freitas, Kelen; Carroll, F Ivy; Negus, S Stevens

    2016-02-01

    Intracranial self-stimulation (ICSS) is one type of preclinical procedure for research on pharmacological mechanisms that mediate abuse potential of drugs acting at various targets, including nicotinic acetylcholine receptors (nAChRs). This study compared effects of the nonselective nAChR agonist nicotine (0.032-1.0 mg/kg) and the α4β2-selective nAChR agonist 5-I-A-85380 (0.01-1.0 mg/kg) on ICSS in male Sprague-Dawley rats. Rats were implanted with electrodes targeting the medial forebrain bundle at the level of the lateral hypothalamus and trained to respond under a fixed-ratio 1 schedule for a range of brain stimulation frequencies (158-56 Hz). A broad range of 5-I-A-85380 doses produced an abuse-related increase (or "facilitation") of low ICSS rates maintained by low brain-stimulation frequencies, and this effect was blocked by both the nonselective nAChR antagonist mecamylamine and the selective α4β2 antagonist dihyrdo-β-erythroidine (DHβE). Conversely, nicotine produced weaker ICSS facilitation across a narrower range of doses, and higher nicotine doses decreased high rates of ICSS maintained by high brain-stimulation frequencies. The rate-decreasing effects of a high nicotine dose were blocked by mecamylamine but not DHβE. Chronic nicotine treatment produced selective tolerance to rate-decreasing effects of nicotine but did not alter ICSS rate-increasing effects of nicotine. These results suggest that α4β2 receptors are sufficient to mediate abuse-related rate-increasing effects of nAChR agonists in this ICSS procedure. Conversely, nicotine effects at non-α4β2 nAChRs appear to oppose and limit abuse-related effects mediated by α4β2 receptors, although tolerance can develop to these non-α4β2 effects. Selective α4β2 agonists may have higher abuse potential than nicotine. PsycINFO Database Record (c) 2016 APA, all rights reserved.

  15. A diversity index for model space selection in the estimation of benchmark and infectious doses via model averaging.

    PubMed

    Kim, Steven B; Kodell, Ralph L; Moon, Hojin

    2014-03-01

    In chemical and microbial risk assessments, risk assessors fit dose-response models to high-dose data and extrapolate downward to risk levels in the range of 1-10%. Although multiple dose-response models may be able to fit the data adequately in the experimental range, the estimated effective dose (ED) corresponding to an extremely small risk can be substantially different from model to model. In this respect, model averaging (MA) provides more robustness than a single dose-response model in the point and interval estimation of an ED. In MA, accounting for both data uncertainty and model uncertainty is crucial, but addressing model uncertainty is not achieved simply by increasing the number of models in a model space. A plausible set of models for MA can be characterized by goodness of fit and diversity surrounding the truth. We propose a diversity index (DI) to balance between these two characteristics in model space selection. It addresses a collective property of a model space rather than individual performance of each model. Tuning parameters in the DI control the size of the model space for MA. © 2013 Society for Risk Analysis.

  16. Traditional medicine and gastroprotective crude drugs.

    PubMed

    Schmeda-Hirschmann, Guillermo; Yesilada, Erdem

    2005-08-22

    A frequent question when dealing with the search for gastroprotective compounds from natural sources is how far or close are both the plant preparations and extract amounts from the doses recommended in traditional medicine and what should be considered realistic levels for experimental studies. The administration way is oral and therefore extracts and products should be administered by gavage when looking for validation of ethnopharmacological uses. Suggestions of doses for both crude extracts and pure compounds are presented and discussed. For plant extracts prepared from single herbs and herbal mixtures, dose-response studies in the range between 100 and 300 mg/kg are suggested, with more than a single gastric ulcer model either in rats or mice. A suitable reference compound should be used according to the ulcer model and in doses resembling those used for human patients. For pure compounds and structure-activity studies or trends, dose-response results should be provided for at least a parent compound in order to select a reasonable dose for comparison purposes. We suggest an evaluation of the activity of the parent compound in the 50-300 mg/kg range and to look for structural modification leading to derivatives with similar or higher gastroprotective effects than the reference antiulcer compounds.

  17. Consideration of the ICRP 2006 revised tissue weighting factors on age-dependent values of the effective dose for external photons

    NASA Astrophysics Data System (ADS)

    Lee, Choonsik; Lee, Choonik; Han, Eun Young; Bolch, Wesley E.

    2007-01-01

    The effective dose recommended by the International Commission on Radiological Protection (ICRP) is the sum of organ equivalent doses weighted by corresponding tissue weighting factors, wT. ICRP is in the process of revising its 1990 recommendations on the effective dose where new values of organs and tissue weighting factors have been proposed and published in draft form for consultation by the radiological protection community. In its 5 June 2006 draft recommendations, new organs and tissues have been introduced in the effective dose which do not exist within the 1987 Oak Ridge National Laboratory (ORNL) phantom series (e.g., salivary glands). Recently, the investigators at University of Florida have updated the series of ORNL phantoms by implementing new organ models and adopting organ-specific elemental composition and densities. In this study, the effective dose changes caused by the transition from the current recommendation of ICRP Publication 60 to the 2006 draft recommendations were investigated for external photon irradiation across the range of ICRP reference ages (newborn, 1-year, 5-year, 10-year, 15-year and adult) and for six idealized irradiation geometries: anterior-posterior (AP), posterior-anterior (PA), left-lateral (LLAT), right-lateral (RLAT), rotational (ROT) and isotropic (ISO). Organ-absorbed doses were calculated by implementing the revised ORNL phantoms in the Monte Carlo radiation transport code, MCNPX2.5, after which effective doses were calculated under the 1990 and draft 2006 evaluation schemes of the ICRP. Effective doses calculated under the 2006 draft scheme were slightly higher than estimated under ICRP Publication 60 methods for all irradiation geometries exclusive of the AP geometry where an opposite trend was observed. The effective doses of the adult phantom were more greatly affected by the change in tissue weighting factors than that seen within the paediatric members of the phantom series. Additionally, dose conversion coefficients for newly identified radiosensitive organs—salivary glands, gall bladder, heart and prostate—were reported, as well as the brain, which was originally considered in ICRP Publication 60 as a member of the remainder category of the effective dose.

  18. The Biological Effectiveness of Silicon Ions is Significantly Higher than Iron Ions for the Induction of Chromosome Damage in Human Lymphocytes

    NASA Technical Reports Server (NTRS)

    George, Kerry; Hada, Megumi; Cucinotta, F. A.

    2010-01-01

    Chromosome aberrations were measured in human peripheral blood lymphocytes after in vitro exposure to Si-28-ions with energies ranging from 90 to 600 MeV/u, or Fe-56-ions with energies ranging from 200 to 5,000 MeV/u. The LET of the various Fe beams in this study ranged from 145 to 440 keV/micron and the LET Si ions ranged from 48 to 158 keV/micron. Doses delivered were in the 10 to 200 cGy range. Dose response curves for chromosome exchanges in cells at first division after exposure, measured using fluorescence in situ hybridization (FISH) with whole chromosome probes, were fitted with linear or linear-quadratic functions. The relative biological effectiveness (RBE) was estimated from the initial slope of the dose response curve for chromosome damage with respect to gamma-rays. The estimates of RBE(sub max) values for total chromosome exchanges ranged from 4.4+/-0.4 to 31.5+/-2.6 for Fe ions, and 11.8+/-1.0 to 42.2+/-3.3 for Si ions. The highest RBE(sub max) value for Fe ions was obtained with the 600 Mev/u beam and 170 MeV/u beam produced the highest RBE(sub max) value for Si ions. For both ions the RBE(sub max) values increased with LET, reaching a maximum at about 180 keV/micron for Fe and about 100 keV/micron for Si, and decreased with further increase in LET.

  19. RADIATION EXPOSURE OF THE POPULATION FROM 222Rn AND OTHER NATURAL RADIONUCLIDES AROUND MOCHOVCE NUCLEAR POWER PLANT, SLOVAKIA.

    PubMed

    Bulko, Martin; Holý, Karol; Pohronská, Žofia; Mullerová, Monika; Böhm, Radoslav; Holá, Ol'ga

    2017-11-01

    In this article, the effective dose to the population from natural sources of ionizing radiation in the vicinity of Mochovce nuclear power plant in Slovakia is presented. All major contributions to the effective dose were taken into account, including the contributions from gamma radiation of soil and rocks, cosmic radiation, and indoor and outdoor radon and thoron. On the basis of recent indoor radon measurements in Slovak cities and publicly available data about radon concentration in the soil air, a roughly linear relationship was found between these variables. Consequently, the annual effective dose from indoor radon and thoron was conservatively estimated. For the area of interest, a map of conservatively estimated potential effective doses was created. For the villages in the vicinity of Mochovce, the conservatively estimated effective dose to the population from natural sources ranged from 5.4 to 14.6 mSv, which is four orders of magnitude higher than the contribution of radioactive discharges from Mochovce nuclear power plant. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  20. A study of atmospheric dispersion of radionuclides at a coastal site using a modified Gaussian model and a mesoscale sea breeze model

    NASA Astrophysics Data System (ADS)

    Venkatesan, R.; Mathiyarasu, R.; Somayaji, K. M.

    Ground level concentration and sky-shine dose due to radioactive emissions from a nuclear power plant at a coastal site have been estimated using the standard Gaussian Plume Model (GPM) and the modified GPM suggested by Misra (Atmospheric Environment 14 (1980) 397), which incorporates fumigation effect under sea breeze condition. The difference in results between these two models is analysed in order to understand their significance and errors that would occur if proper choice were not made. Radioactive sky-shine dose from 41Ar, emitted from a 100 m stack of the nuclear plant is continuously recorded by environmental gamma dose monitors and the data is used to validate the modified GPM. It is observed that the dose values increase by a factor of about 2 times than those of the standard GPM estimates, up to a downwind distance of 6 km during sea breeze hours. In order to examine the dispersion of radioactive effluents in the mesoscale range, a sea breeze model coupled with a particle dispersion model is used. The deposited activity, thyroid dose and sky-shine radioactive dose are simulated for a range of 30 km. In this range, the plume is found to deviate from its straight-line trajectory, as otherwise assumed in GPM. A secondary maximum in the concentration and the sky-shine dose is also observed in the model results. These results are quite significant in realistically estimating the area affected under any unlikely event of an accidental release of radioactivity.

  1. Fast, epithermal and thermal photoneutron dosimetry in air and in tissue equivalent phantom for a high-energy X-ray medical accelerator.

    PubMed

    Sohrabi, Mehdi; Hakimi, Amir

    2018-02-01

    Photoneutron (PN) dosimetry in fast, epithermal and thermal energy ranges originated from the beam and albedo neutrons in high-energy X-ray medical accelerators is highly important from scientific, technical, radiation protection and medical physics points of view. Detailed dose equivalents in the fast, epithermal and thermal PN energy ranges in air up to 2m as well as at 35 positions from the central axis of 12 cross sections of the phantom at different depths were determined in 18MV X-ray beams of a Siemens ONCOR accelerator. A novel dosimetry method based on polycarbonate track dosimeters (PCTD)/ 10 B (with/without cadmium cover) was used to determine and separate different PN dose equivalents in air and in a multilayer polyethylene phantom. Dose equivalent distributions of PNs, as originated from the main beam and/or albedo PNs, on cross-plane, in-plane and diagonal axes in 10cm×10cm fields are reported. PN dose equivalent distributions on the 3 axes have their maxima at the isocenter. Epithermal and thermal PN depth dose equivalent distributions in the phantom for different positions studied peak at ∼3cm depth. The neutron dosimeters used for the first time in such studies are highly effective for separating dose equivalents of PNs in the studied energy ranges (beam and/or albedo). The PN dose equivalent data matrix made available in this paper is highly essential for detailed patient dosimetry in general and for estimating secondary cancer risks in particular. Copyright © 2017. Published by Elsevier GmbH.

  2. Radiation dose effect of DNA repair-related gene expression in mouse white blood cells.

    PubMed

    Li, Ming-juan; Wang, Wei-wei; Chen, Shi-wei; Shen, Qian; Min, Rui

    2011-10-01

    The aim of this study was to screen molecular biomarkers for biodosimetry from DNA repair-related gene expression profiles. Mice were subjected to whole-body exposure with 60Co gamma rays with a dose range of 0-8 Gy at a dose rate of 0.80 Gy/min. RNA was extracted from the peripheral blood of irradiated mice at 4, 8, 12, 24 and 48hrs post-irradiation. The mRNA transcriptional changes of 11 genes related to DNA damage and repair were detected using real-time quantitative polymerase chain reaction (RT-PCR). Of the 11 genes examined, CDKN1A (cyclin-dependent kinase inhibitor 1A or p21, Cip1) and ATM (ataxia telangiectasia mutated) expression levels were found to be heavily up- and down-regulated, respectively, with exposure dose increasing at different post-irradiation times. RAD50 (RAD50 homolog), PLK3 (polo-like kinase 3), GADD45A (growth arrest and DNA damage-inducible, alpha), DDB2 (damage-specific DNA-binding protein 2), BBC3 (BCL2-binding component 3) and IER5 (immediate early response 5) gene expression levels were found to undergo significant oscillating changes over a broad dose range of 2-8 Gy at post-exposure time points observed. Three of the genes were found not to change within the observed exposure dose and post-radiation time ranges. The results of this study add to the biodosimetry with biomarker data pool and will be helpful for constructing appropriate gene expression biomarker systems to evaluate radiation exposure doses.

  3. A dose-ranging study of the effects of mequitazine on actual driving, memory and psychomotor performance as compared to dexchlorpheniramine, cetirizine and placebo.

    PubMed

    Theunissen, E L; Vermeeren, A; van Oers, A C M; van Maris, I; Ramaekers, J G

    2004-02-01

    Mequitazine is a so-called 'non-sedative' second-generation antihistamine even though it has never been firmly established that this drug's sedative potential actually differs from that of the 'sedative' first-generation antihistamines. The present study compares the sedative effects of three doses of mequitazine on actual driving, psychomotor performance and memory with those of a first- and a second-generation antihistamine. Eighteen healthy volunteers received on separate days a single dose of 5, 10 and 15 mg mequitazine, 10 mg cetirizine, 6 mg dexchlorpheniramine and placebo. Drug effects were assessed using two actual driving tests (highway-driving test and car-following test), cognitive and psychometric tests (tracking, divided attention, memory, reasoning and critical flicker fusion), pupil size and questionnaires. Highway-driving data revealed an overall effect of Treatment on the standard deviation of lateral position (SDLP). Dexchlorpheniramine impaired driving performance as indicated by a significant rise in SDLP. Mequitazine significantly increased SDLP in a dose-related manner, but the separate dose effects failed to reach statistical significance. Divided attention performance was also affected by Treatment. Reaction time (RT) during mequitazine treatments increased in a dose-related manner and significantly differed from placebo at the highest dose. Subjects reported to be less alert after treatment with dexchlorpheniramine. Cetirizine did not affect performance in any of the tasks. It was concluded that mequitazine is mildly sedating. The effects of mequitazine are comparable to those of other second-generation antihistamines, in that it causes mild driving impairment, particularly at higher doses.

  4. SU-E-T-129: Dosimetric Evaluation of the Impact of Density Correction On Dose Calculation of Breast Cancer Treatment: A Study Based On RTOG 1005 Cases

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, J; Yu, Y

    Purpose: RTOG 1005 requires density correction in the dose calculation of breast cancer radiation treatment. The aim of the study was to evaluate the impact of density correction on the dose calculation. Methods: Eight cases were studied, which were planned on an XiO treatment planning system with pixel-by-pixel density correction using a superposition algorithm, following RTOG 1005 protocol requirements. Four were protocol Arm 1 (standard whole breast irradiation with sequential boost) cases and four were Arm 2 (hypofractionated whole breast irradiation with concurrent boost) cases. The plans were recalculated with the same monitor units without density correction. Dose calculations withmore » and without density correction were compared. Results: Results of Arm 1 and Arm 2 cases showed similar trends in the comparison. The average differences between the calculations with and without density correction (difference = Without - With) among all the cases were: -0.82 Gy (range: -2.65∼−0.18 Gy) in breast PTV Eval D95, −0.75 Gy (range: −1.23∼0.26 Gy) in breast PTV Eval D90, −1.00 Gy (range: −2.46∼−0.29 Gy) in lumpectomy PTV Eval D95, −0.78 Gy (range: −1.30∼0.11 Gy) in lumpectomy PTV Eval D90, −0.43% (range: −0.95∼−0.14%) in ipsilateral lung V20, −0.81% (range: −1.62∼−0.26%) in V16, −1.95% (range: −4.13∼−0.84%) in V10, −2.64% (−5.55∼−1.04%) in V8, −4.19% (range: −6.92∼−1.81%) in V5, and −4.95% (range: −7.49∼−2.01%) in V4, respectively. The differences in other normal tissues were minimal. Conclusion: The effect of density correction was observed in breast target doses (an average increase of ∼1 Gy in D95 and D90, compared to the calculation without density correction) and exposed ipsilateral lung volumes in low dose region (average increases of ∼4% and ∼5% in V5 and V4, respectively)« less

  5. Poster — Thur Eve — 27: Flattening Filter Free VMAT Quality Assurance: Dose Rate Considerations for Detector Response

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Viel, Francis; Duzenli, Cheryl; British Columbia Cancer Agency, Department of Medical Physics, Vancouver Centre

    2014-08-15

    Introduction: Radiation detector responses can be affected by dose rate. Due to higher dose per pulse and wider range of mu rates in FFF beams, detector responses should be characterized prior to implementation of QA protocols for FFF beams. During VMAT delivery, the MU rate may also vary dramatically within a treatment fraction. This study looks at the dose per pulse variation throughout a 3D volume for typical VMAT plans and the response characteristics for a variety of detectors, and makes recommendations on the design of QA protocols for FFF VMAT QA. Materials and Methods: Linac log file data andmore » a simplified dose calculation algorithm are used to calculate dose per pulse for a variety of clinical VMAT plans, on a voxel by voxel basis, as a function of time in a cylindrical phantom. Diode and ion chamber array responses are characterized over the relevant range of dose per pulse and dose rate. Results: Dose per pulse ranges from <0.1 mGy/pulse to 1.5 mGy/pulse in a typical VMAT treatment delivery using the 10XFFF beam. Diode detector arrays demonstrate increased sensitivity to dose (+./− 3%) with increasing dose per pulse over this range. Ion chamber arrays demonstrate decreased sensitivity to dose (+/− 1%) with increasing dose rate over this range. Conclusions: QA protocols should be designed taking into consideration inherent changes in detector sensitivity with dose rate. Neglecting to account for changes in detector response with dose per pulse can lead to skewed QA results.« less

  6. Validation of a MOSFET dosemeter system for determining the absorbed and effective radiation doses in diagnostic radiology.

    PubMed

    Manninen, A-L; Kotiaho, A; Nikkinen, J; Nieminen, M T

    2015-04-01

    This study aimed to validate a MOSFET dosemeter system for determining absorbed and effective doses (EDs) in the dose and energy range used in diagnostic radiology. Energy dependence, dose linearity and repeatability of the dosemeter were examined. The absorbed doses (ADs) were compared at anterior-posterior projection and the EDs were determined at posterior-anterior, anterior-posterior and lateral projections of thoracic imaging using an anthropomorphic phantom. The radiation exposures were made using digital radiography systems. This study revealed that the MOSFET system with high sensitivity bias supply set-up is sufficiently accurate for AD and ED determination. The dosemeter is recommended to be calibrated for energies <60 and >80 kVp. The entrance skin dose level should be at least 5 mGy to minimise the deviation of the individual dosemeter dose. For ED determination, dosemeters should be implanted perpendicular to the surface of the phantom to prevent the angular dependence error. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Blonanserin – A Novel Antianxiety and Antidepressant Drug? An Experimental Study

    PubMed Central

    Limaye, Ramchandra Prabhakar; Patil, Aditi Nitin

    2016-01-01

    Introduction Many psychiatric disorders show signs and symptoms of anxiety and depression. A drug with both, effects and lesser adverse effects is always desired. Blonanserin is a novel drug with postulated effect on anxiety and depression. Aim The study was aimed to evaluate the effect of Blonanserin on anxiety and depression in animal models. Materials and Methods By using elevated plus maze test and forced swimming test, the antianxiety and antidepressant effects were evaluated. Animal ethics protocols were followed strictly. Total 50 rats (10 rats per group) were used for each test. As a control drug diazepam and imipramine were used in elevated plus maze and forced swimming test respectively. Blonanserin was tested for 3 doses 0.075, 0.2 and 0.8mg. These doses were selected from previous references as well as by extrapolating human doses. Results This study showed an antianxiety effect of Blonanserin comparable to diazepam, which was statistically significant. Optimal effect was observed with 0.075mg, followed by 0.2 and 0.8mg. It also showed an antidepressant effect which was statistically significant. Optimal effect was observed at 0.2mg dose. Conclusion The results showed that at a dose range of 0.075 and 0.2mg Blonanserin has potential to exert an adjuvant antianxiety and antidepressant activity in animal models. In order to extrapolate this in patient, longer clinical studies with comparable doses should be planned. The present study underlines potential of Blonanserin as a novel drug for such studies. PMID:27790460

  8. Blonanserin - A Novel Antianxiety and Antidepressant Drug? An Experimental Study.

    PubMed

    Limaye, Ramchandra Prabhakar; Patil, Aditi Nitin

    2016-09-01

    Many psychiatric disorders show signs and symptoms of anxiety and depression. A drug with both, effects and lesser adverse effects is always desired. Blonanserin is a novel drug with postulated effect on anxiety and depression. The study was aimed to evaluate the effect of Blonanserin on anxiety and depression in animal models. By using elevated plus maze test and forced swimming test, the antianxiety and antidepressant effects were evaluated. Animal ethics protocols were followed strictly. Total 50 rats (10 rats per group) were used for each test. As a control drug diazepam and imipramine were used in elevated plus maze and forced swimming test respectively. Blonanserin was tested for 3 doses 0.075, 0.2 and 0.8mg. These doses were selected from previous references as well as by extrapolating human doses. This study showed an antianxiety effect of Blonanserin comparable to diazepam, which was statistically significant. Optimal effect was observed with 0.075mg, followed by 0.2 and 0.8mg. It also showed an antidepressant effect which was statistically significant. Optimal effect was observed at 0.2mg dose. The results showed that at a dose range of 0.075 and 0.2mg Blonanserin has potential to exert an adjuvant antianxiety and antidepressant activity in animal models. In order to extrapolate this in patient, longer clinical studies with comparable doses should be planned. The present study underlines potential of Blonanserin as a novel drug for such studies.

  9. Infantile hemangioma: treatment with short course systemic corticosteroid therapy as an alternative for propranolol.

    PubMed

    Nieuwenhuis, Klaske; de Laat, Peter C J; Janmohamed, Sherief R; Madern, Gerard C; Oranje, Arnold P

    2013-01-01

    Infantile hemangiomas (IHs) are increasingly being treated with propranolol or other beta-blockers, but before this therapeutic option was available, oral glucocorticosteroids (GCSs) were the criterion standard treatment and are still the alternative modality in problematic cases. Nevertheless, there is no standard treatment protocol for the dose and duration of GCSs. Long-term treatment with GCSs is associated with unwanted side effects such as growth suppression, behavioral changes, and reflux. Twenty-one children with troublesome IHs were treated according to an algorithm with 3 mg/kg/day of oral prednisolone divided three times per day with varying duration and number of GCS courses. Two blinded investigators independently interpreted therapy results using the Hemangioma Activity Score (HAS). Side effects were determined according to reports in patient charts and parental questionnaires. The median duration of a short course of GCSs was 2 weeks (range 1-6 weeks). The number of courses was 2 (range 1-5). The median cumulative dose was 91 mg/kg. Growth stabilized in all patients, with a good response (>50% reduction in HAS) in 62% and a favorable response (30-50% reduction is HAS) in 23%. Twelve of the 21 children (57%) had minor side effects. Persistent side effects did not occur. Intermittent short course, systemic, high-dose GCS therapy is an effective and safe treatment modality for IH, with a substantially lower cumulative dose of GCSs compared to prolonged therapy and no major side effects. This treatment is an alternative in cases in which propranolol fails or is contraindicated. © 2012 Wiley Periodicals, Inc.

  10. DMLC tracking and gating can improve dose coverage for prostate VMAT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Colvill, E.; Northern Sydney Cancer Centre, Royal North Shore Hospital, Sydney, NSW 2065; School of Physics, University of Sydney, NSW 2006

    2014-09-15

    Purpose: To assess and compare the dosimetric impact of dynamic multileaf collimator (DMLC) tracking and gating as motion correction strategies to account for intrafraction motion during conventionally fractionated prostate radiotherapy. Methods: A dose reconstruction method was used to retrospectively assess the dose distributions delivered without motion correction during volumetric modulated arc therapy fractions for 20 fractions of five prostate cancer patients who received conventionally fractionated radiotherapy. These delivered dose distributions were compared with the dose distributions which would have been delivered had DMLC tracking or gating motion correction strategies been implemented. The delivered dose distributions were constructed by incorporating themore » observed prostate motion with the patient's original treatment plan to simulate the treatment delivery. The DMLC tracking dose distributions were constructed using the same dose reconstruction method with the addition of MLC positions from Linac log files obtained during DMLC tracking simulations with the observed prostate motions input to the DMLC tracking software. The gating dose distributions were constructed by altering the prostate motion to simulate the application of a gating threshold of 3 mm for 5 s. Results: The delivered dose distributions showed that dosimetric effects of intrafraction prostate motion could be substantial for some fractions, with an estimated dose decrease of more than 19% and 34% from the planned CTVD{sub 99%} and PTV D{sub 95%} values, respectively, for one fraction. Evaluation of dose distributions for DMLC tracking and gating deliveries showed that both interventions were effective in improving the CTV D{sub 99%} for all of the selected fractions to within 4% of planned value for all fractions. For the delivered dose distributions the difference in rectum V{sub 65%} for the individual fractions from planned ranged from −44% to 101% and for the bladder V{sub 65%} the range was −61% to 26% from planned. The application of tracking decreased the maximum rectum and bladder V{sub 65%} difference to 6% and 4%, respectively. Conclusions: For the first time, the dosimetric impact of DMLC tracking and gating to account for intrafraction motion during prostate radiotherapy has been assessed and compared with no motion correction. Without motion correction intrafraction prostate motion can result in a significant decrease in target dose coverage for a small number of individual fractions. This is unlikely to effect the overall treatment for most patients undergoing conventionally fractionated treatments. Both DMLC tracking and gating demonstrate dose distributions for all assessed fractions that are robust to intrafraction motion.« less

  11. Ionizing radiation sensitivity of the ocular lens and its dose rate dependence.

    PubMed

    Hamada, Nobuyuki

    2017-10-01

    In 2011, the International Commission on Radiological Protection reduced the threshold for the lens effects of low linear energy transfer (LET) radiation. On one hand, the revised threshold of 0.5 Gy is much lower than previously recommended thresholds, but mechanisms behind high radiosensitivity remain incompletely understood. On the other hand, such a threshold is independent of dose rate, in contrast to previously recommended separate thresholds each for single and fractionated/protracted exposures. Such a change was made predicated on epidemiological evidence suggesting that a threshold for fractionated/protracted exposures is not higher than an acute threshold, and that a chronic threshold is uncertain. Thus, the dose rate dependence is still unclear. This paper therefore reviews the current knowledge on the radiosensitivity of the lens and the dose rate dependence of radiation cataractogenesis, and discusses its mechanisms. Mounting biological evidence indicates that the lens cells are not necessarily radiosensitive to cell killing, and the high radiosensitivity of the lens thus appears to be attributable to other mechanisms (e.g., excessive proliferation, abnormal differentiation, a slow repair of DNA double-strand breaks, telomere, senescence, crystallin changes, non-targeted effects and inflammation). Both biological and epidemiological evidence generally supports the lack of dose rate effects. However, there is also biological evidence for the tissue sparing dose rate (or fractionation) effect of low-LET radiation and an enhancing inverse dose fractionation effect of high-LET radiation at a limited range of LET. Emerging epidemiological evidence in chronically exposed individuals implies the inverse dose rate effect. Further biological and epidemiological studies are warranted to gain deeper knowledge on the radiosensitivity of the lens and dose rate dependence of radiation cataractogenesis.

  12. A Unified Probabilistic Framework for Dose-Response Assessment of Human Health Effects.

    PubMed

    Chiu, Weihsueh A; Slob, Wout

    2015-12-01

    When chemical health hazards have been identified, probabilistic dose-response assessment ("hazard characterization") quantifies uncertainty and/or variability in toxicity as a function of human exposure. Existing probabilistic approaches differ for different types of endpoints or modes-of-action, lacking a unifying framework. We developed a unified framework for probabilistic dose-response assessment. We established a framework based on four principles: a) individual and population dose responses are distinct; b) dose-response relationships for all (including quantal) endpoints can be recast as relating to an underlying continuous measure of response at the individual level; c) for effects relevant to humans, "effect metrics" can be specified to define "toxicologically equivalent" sizes for this underlying individual response; and d) dose-response assessment requires making adjustments and accounting for uncertainty and variability. We then derived a step-by-step probabilistic approach for dose-response assessment of animal toxicology data similar to how nonprobabilistic reference doses are derived, illustrating the approach with example non-cancer and cancer datasets. Probabilistically derived exposure limits are based on estimating a "target human dose" (HDMI), which requires risk management-informed choices for the magnitude (M) of individual effect being protected against, the remaining incidence (I) of individuals with effects ≥ M in the population, and the percent confidence. In the example datasets, probabilistically derived 90% confidence intervals for HDMI values span a 40- to 60-fold range, where I = 1% of the population experiences ≥ M = 1%-10% effect sizes. Although some implementation challenges remain, this unified probabilistic framework can provide substantially more complete and transparent characterization of chemical hazards and support better-informed risk management decisions.

  13. Effect of supplementation with flaxseed oil and different doses of fish oil for 2 weeks on plasma phosphatidylcholine fatty acids in young women.

    PubMed

    Hodson, Leanne; Crowe, Francesca L; McLachlan, Kirsten J; Skeaff, C Murray

    2018-06-01

    Although assumed, it remains unclear that fatty acid (FA) biomarkers of n-3 long-chain PUFA reflect wide ranges of intake. However, to be utilised as biomarkers, to predict dietary intake, dose-response curves that cover a spectrum of intakes are required. The aim of the study was to investigate whether the FA composition of plasma phosphatidylcholine (PC) is a sensitive biomarker of n-3 FAs from fish oil, across a range of supplementation doses, and alpha-linolenic acid (ALA) supplementation, in young, healthy women. A total of 303 young women were randomised to intakes ranging between 0.33 and 4.50 g EPA+DHA/day from fish oil (not all doses used in each year) or flaxseed oil (5.90-6.60 g/d) daily for 14 days in a series of trials, over 5 years. Fasting blood was collected at baseline (day 0) and day 14 and plasma PC FA composition, total and HDL-cholesterol and triglyceride concentrations measured. Fourteen days supplementation with fish oil significantly (P < 0.01) increased, in a dose-dependent fashion, plasma PC EPA, DPA and DHA at all doses except 1 and 3 mL/day. For the combined group of women who consumed any fish oil there was a 16% (P < 0.01) decrease in plasma triacylglycerol concentrations after 14 days supplementation. Flaxseed oil supplementation for 14 day resulted in significant (P < 0.01) increases in ALA, EPA and DPA, whilst DHA remained unchanged. Our data demonstrate plasma PC is a sensitive biomarker of n-3 FA intake and reflects changes within 14 days across a range of intakes.

  14. Dose-dependent metabolic disposition of hydroxytyrosol and formation of mercapturates in rats.

    PubMed

    Kotronoulas, Aristotelis; Pizarro, Nieves; Serra, Aida; Robledo, Patricia; Joglar, Jesús; Rubió, Laura; Hernaéz, Alvaro; Tormos, Carmen; Motilva, Ma José; Fitó, Montserrat; Covas, Maria-Isabel; Solà, Rosa; Farré, Magí; Saez, Guillermo; de la Torre, Rafael

    2013-11-01

    Hydroxytyrosol (HT), one of the major polyphenols present in olive oil, is known to possess a high antioxidant capacity. The aim of the present study was to investigate dose dependent (0, 1, 10 and 100 mg/kg) alterations in the metabolism of HT in rats since it has been reported that metabolites may contribute to biological effects. Special attention was paid to the activation of the semiquinone-quinone oxidative cycle and the formation of adducts with potential deleterious effects. Thus, we developed a novel analytical methodology to monitor the in vivo formation of the HT mercapturate, N-acetyl-5-S-cysteinyl-hydroxytyrosol in urine samples. Biomarkers of hepatic and renal toxicity were evaluated within the dose range tested. Following HT administration, dose-dependent effects were observed for the recovery of all the metabolites studied. At the lowest dose of 1 mg/kg, the glucuronidation pathway was the most relevant (25-30%), with lower recoveries for sulfation (14%), while at the highest dose of 100 mg/kg, sulfation was the most prevalent (75%). In addition, we report for the first time the formation of the mercapturate conjugate of HT in a dose-dependent manner. The biochemical data did not reveal significant toxic effects of HT at any of the doses studied. An increase in the GSH/GSSG ratio at the highest dose was observed indicating that the products of HT autoxidation are counteracted by glutathione, resulting in their detoxification. These results indicate that the metabolic disposition of HT is highly dependent on the dose ingested. Copyright © 2013. Published by Elsevier Ltd.

  15. EFFECTS OF REACTOR RADIATION ON THE ELECTRICAL PROPERTIES OF ELECTRONIC COMPONENTS. PART II. VACUUM TUBES, TRANSISTORS AND TRANSFORMERS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miglicco, P.S.; Spears, A.B.; Howell, D.B.

    1957-11-22

    Several types of vacuum tubes, transistors and transformers were irradiated with the Convair-Fort Worth Ground Test Reactor. The components were subjected to five different fluxes ranging from 10/sup 6/ to 10/sup 10/n/sub F// cm/sup 2/-sec and 10/sup 8/ to 10/sup 12/ gamma /cm/sup 2/-sec. The total integrated flux received was 10/sup 14/n/sub F//cm/sup 2/ and 10/sup 16/ gamma / cm/sup 2/. An attempt was made to separate radiation damage as a function of dose rate from radiation damage as a function of dose. The components were irradiated first at several low dose rates so that dose rate effects could bemore » studied while the accumulated dose was small, and then at a high dose rate to obtain the desired dose. However, because of the long time required to complete a data gathering cycle, the accumulated dose hindered the separation of dose rate and dose effects. Thus, in the report, the damage to the components is reported as a function of integrated flux. For reference, the integrated flux accumulated at each power level is given. The transformers exhibited the greatest resistance to irradiation. Every important parameter of the transistors deteriorated in the radiation field. Postirradiation tests at room temperature showed no significant recovery in the transistor's characteristics. The plate current of 65% of the tubes tested increased during irradiation. This effect, based on postirradiation tests, is considered permanent. (auth)« less

  16. An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Warren, Samantha, E-mail: samantha.warren@oncology.ox.ac.uk; Partridge, Mike; Bolsi, Alessandra

    Purpose: Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. Methods andmore » Materials: For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV){sub 50Gy} or PTV{sub 62.5Gy} (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose–volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. Results: SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D{sub 98} was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D{sub 98} was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D{sub 98} was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D{sub 98} was lower by 0.3% to 2.2% of the prescribed GTV dose. Conclusions: The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial.« less

  17. An Analysis of Plan Robustness for Esophageal Tumors: Comparing Volumetric Modulated Arc Therapy Plans and Spot Scanning Proton Planning

    PubMed Central

    Warren, Samantha; Partridge, Mike; Bolsi, Alessandra; Lomax, Anthony J.; Hurt, Chris; Crosby, Thomas; Hawkins, Maria A.

    2016-01-01

    Purpose Planning studies to compare x-ray and proton techniques and to select the most suitable technique for each patient have been hampered by the nonequivalence of several aspects of treatment planning and delivery. A fair comparison should compare similarly advanced delivery techniques from current clinical practice and also assess the robustness of each technique. The present study therefore compared volumetric modulated arc therapy (VMAT) and single-field optimization (SFO) spot scanning proton therapy plans created using a simultaneous integrated boost (SIB) for dose escalation in midesophageal cancer and analyzed the effect of setup and range uncertainties on these plans. Methods and Materials For 21 patients, SIB plans with a physical dose prescription of 2 Gy or 2.5 Gy/fraction in 25 fractions to planning target volume (PTV)50Gy or PTV62.5Gy (primary tumor with 0.5 cm margins) were created and evaluated for robustness to random setup errors and proton range errors. Dose–volume metrics were compared for the optimal and uncertainty plans, with P<.05 (Wilcoxon) considered significant. Results SFO reduced the mean lung dose by 51.4% (range 35.1%-76.1%) and the mean heart dose by 40.9% (range 15.0%-57.4%) compared with VMAT. Proton plan robustness to a 3.5% range error was acceptable. For all patients, the clinical target volume D98 was 95.0% to 100.4% of the prescribed dose and gross tumor volume (GTV) D98 was 98.8% to 101%. Setup error robustness was patient anatomy dependent, and the potential minimum dose per fraction was always lower with SFO than with VMAT. The clinical target volume D98 was lower by 0.6% to 7.8% of the prescribed dose, and the GTV D98 was lower by 0.3% to 2.2% of the prescribed GTV dose. Conclusions The SFO plans achieved significant sparing of normal tissue compared with the VMAT plans for midesophageal cancer. The target dose coverage in the SIB proton plans was less robust to random setup errors and might be unacceptable for certain patients. Robust optimization to ensure adequate target coverage of SIB proton plans might be beneficial. PMID:27084641

  18. Resistance of Salmonella typhimurium TA 1535 to O6-guanine methylation and mutagenesis induced by low doses of N-methyl-N'-nitro-N-nitrosoguanidine: an apparent constitutive repair activity.

    PubMed

    Guttenplan, J B; Milstein, S

    1982-01-01

    Salmonella tester strains which are reverted by base-pair substitution mutagens are relatively insensitive to the mutagenic effects of N-methyl-N-nitroso compounds. One reason for this insensitivity is the ability of these strains to withstand low doses of these compounds before they become sensitive to their mutagenic effects. In this report it is shown that mutagenesis induced by treatment of Salmonella typhimurium TA 1535 with N-methyl-N'-nitro-N-nitroso-guanidine (MNNG) in buffer is biphasic with a low sensitivity range at low doses where little mutagenesis occurs, followed by a high sensitivity range whose onset begins after an apparent threshold dose has been exceeded. levels of O6-methylguanine (O6-MeG) in the DNA extracted from the bacteria follow a similar dose-response curve suggesting a dependency of mutagenesis on O6-MeG. In contrast, levels of 7-methylguanine (7-MeG) in the DNA increase linearly with dose. O6-MeG was undetectable at the lowest dose of MNNG whereas 7-MeG was readily detectable. Although such resistance to O6-alkylation has been demonstrated in MNNG- pretreated (adapted) E. coli, it has not been reported in unpretreated cells. Then isolated DNA was treated with MNNG a linear dose-response in the generation of O6-MeG was observed. The lack of O6-MeG in DNA isolated from MNNG treated cells after low doses is attributed to a saturable, constitutive repair activity in the bacteria. An attempt to observe the removal of O6-MeG from the bacteria after exposure to a short challenge dose of N-nitroso-N-methylurea (NMU) followed by a subsequent incubation in buffer was unsuccessful, probably because all the repair occurred within the time necessary to treat and lyse the cells.

  19. Pharmacokinetics of flunixin meglumine in mature swine after intravenous, intramuscular and oral administration

    PubMed Central

    2013-01-01

    Background The purpose of this study was to determine intravenous (IV), intramuscular (IM) and oral (PO) FM PK in mature swine. Appropriate pain management for lameness in swine is a critical control point for veterinarians and producers, but science-based guidance on optimal housing, management and treatment of lameness is deficient. Six mature swine (121–168 kg) were administered an IV, IM, or PO dose of flunixin meglumine at a target dose of 2.2 mg/kg in a cross-over design with a 10 day washout period between treatments. Plasma samples collected up to 48 hours post-administration were analyzed by high pressure liquid chromatography and mass spectrometry (HPLC-MS) followed by non-compartmental pharmacokinetic analysis. Results No adverse effects were observed with flunixin meglumine administration for all routes. Flunixin meglumine was administered at an actual mean dose of 2.21 mg/kg (range: 2.05-2.48 mg/kg) IV, IM and PO. A mean peak plasma concentration (CMAX) for IM and PO administration was 3748 ng/ml (range: 2749–6004 ng/ml) and 946 ng/ml (range: 554–1593 ng/ml), respectively. TMAX was recorded at 1.00 hour (range: 0.50-2.00 hours) and 0.61 hours (range: 0.17-2.00 hours) after PO and IM administration. Half-life (T ½ λz) for IV, IM and PO administration was 6.29 hours (range: 4.84-8.34 hours), 7.49 hours (range: 5.55-12.98 hours) and 7.08 hours (range: 5.29-9.15 hours) respectively. In comparison, bioavailability (F) for PO administration was 22% (range: 11-44%) compared to IM F at 76% (range: 54-92%). Conclusions The results of the present study suggest that FM oral administration is not the most effective administration route for mature swine when compared to IV and IM. Lower F and Cmax of PO-FM in comparison to IM-FM suggest that PO-FM is less likely to be an effective therapeutic administration route. PMID:23941181

  20. Dose to the Developing Dentition During Therapeutic Irradiation: Organ at Risk Determination and Clinical Implications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thompson, Reid F., E-mail: Reid.Thompson@uphs.upenn.edu; Department of Radiation Oncology, University of Pennsylvania, Philadelphia, Pennsylvania; Schneider, Ralf A., E-mail: ralf.schneider@psi.ch

    Purpose: Irradiation of pediatric facial structures can cause severe impairment of permanent teeth later in life. We therefore focused on primary and permanent teeth as organs at risk, investigating the ability to identify individual teeth in children and infants and to correlate dose distributions with subsequent dental toxicity. Methods and Materials: We retrospectively reviewed 14 pediatric patients who received a maximum dose >20 Gy(relative biological effectiveness, RBE) to 1 or more primary or permanent teeth between 2003 and 2009. The patients (aged 1-16 years) received spot-scanning proton therapy with 46 to 66 Gy(RBE) in 23 to 33 daily fractions formore » a variety of tumors, including rhabdomyosarcoma (n=10), sarcoma (n=2), teratoma (n=1), and carcinoma (n=1). Individual teeth were contoured on axial slices from planning computed tomography (CT) scans. Dose-volume histogram data were retrospectively obtained from total calculated delivered treatments. Dental follow-up information was obtained from external care providers. Results: All primary teeth and permanent incisors, canines, premolars, and first and second molars were identifiable on CT scans in all patients as early as 1 year of age. Dose-volume histogram analysis showed wide dose variability, with a median 37 Gy(RBE) per tooth dose range across all individuals, and a median 50 Gy(RBE) intraindividual dose range across all teeth. Dental follow-up revealed absence of significant toxicity in 7 of 10 patients but severe localized toxicity in teeth receiving >20 Gy(RBE) among 3 patients who were all treated at <4 years of age. Conclusions: CT-based assessment of dose distribution to individual teeth is feasible, although delayed calcification may complicate tooth identification in the youngest patients. Patterns of dental dose exposure vary markedly within and among patients, corresponding to rapid dose falloff with protons. Severe localized dental toxicity was observed in a few patients receiving the largest doses of radiation at the youngest ages; however, multiple factors including concurrent chemotherapy confounded the dose-effect relationship. Further studies with larger cohorts and appropriate controls will be required.« less

  1. Characterization of MOSFET dosimeters for low‐dose measurements in maxillofacial anthropomorphic phantoms

    PubMed Central

    Wolff, Jan E.; Kiljunen, Timo; Schulze, Dirk; Kortesniemi, Mika

    2015-01-01

    The aims of this study were to characterize reinforced metal‐oxide‐semiconductor field‐effect transistor (MOSFET) dosimeters to assess the measurement uncertainty, single exposure low‐dose limit with acceptable accuracy, and the number of exposures required to attain the corresponding limit of the thermoluminescent dosimeters (TLD). The second aim was to characterize MOSFET dosimeter sensitivities for two dental photon energy ranges, dose dependency, dose rate dependency, and accumulated dose dependency. A further aim was to compare the performance of MOSFETs with those of TLDs in an anthropomorphic phantom head using a dentomaxillofacial CBCT device. The uncertainty was assessed by exposing 20 MOSFETs and a Barracuda MPD reference dosimeter. The MOSFET dosimeter sensitivities were evaluated for two photon energy ranges (50–90 kVp) using a constant dose and polymethylmethacrylate backscatter material. MOSFET and TLD comparative point‐dose measurements were performed on an anthropomorphic phantom that was exposed with a clinical CBCT protocol. The MOSFET single exposure low dose limit (25% uncertainty, k=2) was 1.69 mGy. An averaging of eight MOSFET exposures was required to attain the corresponding TLD (0.3 mGy) low‐dose limit. The sensitivity was 3.09±0.13 mV/mGy independently of the photon energy used. The MOSFET dosimeters did not present dose or dose rate sensitivity but, however, presented a 1% decrease of sensitivity per 1000 mV for accumulated threshold voltages between 8300 mV and 17500 mV. The point doses in an anthropomorphic phantom ranged for MOSFETs between 0.24 mGy and 2.29 mGy and for TLDs between 0.25 and 2.09 mGy, respectively. The mean difference was −8%. The MOSFET dosimeters presented statistically insignificant energy dependency. By averaging multiple exposures, the MOSFET dosimeters can achieve a TLD‐comparable low‐dose limit and constitute a feasible method for diagnostic dosimetry using anthropomorphic phantoms. However, for single in vivo measurements (<1.7 mGy) the sensitivity is too low. PACS number: 87.50.wj PMID:26219008

  2. Impact Properties of Irradiated HT9 from the Fuel Duct of FFTF

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Byun, Thak Sang; Maloy, S; Toloczko, M

    2012-01-01

    This paper reports Charpy impact test data for the ACO-3 duct material (HT9) from the Fast Flux Test Facility (FFTF) and its archive material. Irradiation doses for the specimens were in the range of 3 148 dpa and irradiation temperatures in the range of 378 504 oC. The impact tests were performed for the small V-notched Charpy specimens with dimensions of 3 4 27 mm at an impact speed of 3.2 m/s in a 25J capacity machine. Irradiation lowered the upper-shelf energy (USE) and increased the transition temperatures significantly. The shift of transition temperatures was greater after relatively low temperaturemore » irradiation. The USE values were in the range of 5.5 6.7 J before irradiation and decreased to the range of 2 5 J after irradiation. Lower USEs were measured for lower irradiation temperatures and specimens with T-L orientation. For the irradiated specimens, the dose dependences of transition temperature and USE were not significant because of the radiation effect on impact behavior nearly saturated at the lowest dose of about 3 dpa. A comparison showed that the lateral expansion of specimens showed a linear correlation with absorbed impact energy, but with large scatter in the results. The size effect was also discussed to clarify the differences in the impact data of subsize and standard specimens.« less

  3. A Phase I Study of Reduced-Intensity Conditioning and Allogeneic Stem Cell Transplantation Followed by Dose Escalation of Targeted Consolidation Immunotherapy with Gemtuzumab Ozogamicin in Children and Adolescents with CD33+ Acute Myeloid Leukemia.

    PubMed

    Zahler, Stacey; Bhatia, Monica; Ricci, Angela; Roy, Sumith; Morris, Erin; Harrison, Lauren; van de Ven, Carmella; Fabricatore, Sandra; Wolownik, Karen; Cooney-Qualter, Erin; Baxter-Lowe, Lee Ann; Luisi, Paul; Militano, Olga; Kletzel, Morris; Cairo, Mitchell S

    2016-04-01

    Myeloablative conditioning and allogeneic hematopoietic stem cell transplant (alloHSCT) in children with acute myeloid leukemia (AML) in first complete remission (CR1) may be associated with significant acute toxicity and late effects. Reduced-intensity conditioning (RIC) and alloHSCT in children is safe, feasible, and may be associated with less adverse effects. Gemtuzumab ozogamicin (GO) induces a response in 30% of patients with CD33+ relapsed/refractory AML. The dose of GO is significantly lower when combined with chemotherapy. We examined the feasibility and toxicity of RIC alloHSCT followed by GO targeted immunotherapy in children with CD33+ AML in CR1/CR2. Conditioning consisted of fludarabine 30 mg/m2 × 6 days, busulfan 3.2 to 4 mg/kg × 2 days ± rabbit antithymocyte globulin 2 mg/kg × 4 days followed by alloHSCT from matched related/unrelated donors. GO was administered ≥60 days after alloHSCT in 2 doses (8 weeks apart), following a dose-escalation design (4.5, 6, 7.5, and 9 mg/m2). Fourteen patients with average risk AML received RIC alloHSCT and post-GO consolidation: median age 13.5 years at transplant (range, 1 to 21), male-to-female 8:6, and disease status at alloHSCT 11 CR1 and 3 CR2. Eleven patients received alloHSCT from 5-6/6 HLA-matched family donors: 8 received peripheral blood stem cells, 2 received bone marrow, and 1 received related cord blood transplantation. Three patients received an unrelated allograft (two 4-5/6 and one 9/10) from unrelated cord blood unit and bone marrow, respectively. Neutrophil and platelet engraftment was observed in all assessable patients (100%), achieved at median 15.5 days (range, 7 to 31) and 21 days (range, 10 to 52), respectively. Three patients received GO at dose level 1 (4.5 mg/m2 per dose), 5 at dose level 2 (6 mg/m2 per dose), 3 at dose level 3 (7.5 mg/m2 per dose), and 3 at dose level 4 (9 mg/m2 per dose). Three of 14 patients received only 1 dose of GO after alloHSCT. One patient experienced grade III transaminitis, which resolved; no grade IV transaminitis, no grade III/IV hyperbilirubinemia, or sinusoidal obstructive syndrome were observed. The second dose of GO was given at median of 143 days (range, 120 to 209) after alloHSCT. Probability of grades II to IV acute and chronic graft-versus-host disease were 21% and 33.5%, respectively. Probability of overall survival after RIC alloHSCT and GO consolidation at 1 and 5 years was 78% and 61%, respectively. Probability of 5-year event-free survival after RIC alloHSCT and GO consolidation in patients in CR1 was 78%. No dose-limiting toxicities probably or directly related to GO were observed in this cohort. This preliminary data demonstrate that RIC followed by alloHSCT and consolidation with GO appears to be safe in children and adolescents with CD33+ AML in CR1/CR2. A phase II trial is currently underway investigating this approach with a GO dose of 9 mg/m2 per dose. Copyright © 2016 American Society for Blood and Marrow Transplantation. Published by Elsevier Inc. All rights reserved.

  4. Reduction of the unnecessary dose from the over-range area with a spiral dynamic z-collimator: comparison of beam pitch and detector coverage with 128-detector row CT.

    PubMed

    Shirasaka, Takashi; Funama, Yoshinori; Hayashi, Mutsukazu; Awamoto, Shinichi; Kondo, Masatoshi; Nakamura, Yasuhiko; Hatakenaka, Masamitsu; Honda, Hiroshi

    2012-01-01

    Our purpose in this study was to assess the radiation dose reduction and the actual exposed scan length of over-range areas using a spiral dynamic z-collimator at different beam pitches and detector coverage. Using glass rod dosimeters, we measured the unilateral over-range scan dose between the beginning of the planned scan range and the beginning of the actual exposed scan range. Scanning was performed at detector coverage of 80.0 and 40.0 mm, with and without the spiral dynamic z-collimator. The dose-saving ratio was calculated as the ratio of the unnecessary over-range dose, with and without the spiral dynamic z-collimator. In 80.0 mm detector coverage without the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 108, 120, and 126 mm, corresponding to a beam pitch of 0.60, 0.80, and 0.99, respectively. With the spiral dynamic z-collimator, the actual exposed scan length for the over-range area was 48, 66, and 84 mm with a beam pitch of 0.60, 0.80, and 0.99, respectively. The dose-saving ratios with and without the spiral dynamic z-collimator for a beam pitch of 0.60, 0.80, and 0.99 were 35.07, 24.76, and 13.51%, respectively. With 40.0 mm detector coverage, the dose-saving ratios with and without the spiral dynamic z-collimator had the highest value of 27.23% with a low beam pitch of 0.60. The spiral dynamic z-collimator is important for a reduction in the unnecessary over-range dose and makes it possible to reduce the unnecessary dose by means of a lower beam pitch.

  5. EPR/alanine dosimetry for two therapeutic proton beams

    NASA Astrophysics Data System (ADS)

    Marrale, Maurizio; Carlino, Antonio; Gallo, Salvatore; Longo, Anna; Panzeca, Salvatore; Bolsi, Alessandra; Hrbacek, Jan; Lomax, Tony

    2016-02-01

    In this work the analysis of the electron paramagnetic resonance (EPR) response of alanine pellets exposed to two different clinical proton beams employed for radiotherapy is performed. One beam is characterized by a passive delivery technique and is dedicated to the eyes treatment (OPTIS2 beam line). Alanine pellets were irradiated with a 70 MeV proton beam corresponding to 35 mm range in eye tissue. We investigated how collimators with different sizes and shape used to conform the dose to the planned target volume influence the delivered dose. For this purpose we performed measurements with varying the collimator size (Output Factor) and the results were compared with those obtained with other dosimetric techniques (such as Markus chamber and diode detector). This analysis showed that the dosimeter response is independent of collimator diameter if this is larger than or equal to 10 mm. The other beam is characterized by an active spot-scanning technique, the Gantry1 beam line (maximum energy 230 MeV), and is used to treat deep-seated tumors. The dose linearity of alanine response in the clinical dose range was tested and the alanine dose response at selected locations in depth was measured and compared with the TPS planned dose in a quasi-clinical scenario. The alanine response was found to be linear in the dose in the clinical explored range (from 10 to 70 Gy). Furthermore, a depth dose profile in a quasi-clinical scenario was measured and compared to the dose computed by the Treatment Planning System PSIPLAN. The comparison of calibrated proton alanine measurements and TPS dose shows a difference under 1% in the SOBP and a "quenching" effect up to 4% in the distal part of SOBP. The positive dosimetric characteristics of the alanine pellets confirm the feasibility to use these detectors for "in vivo" dosimetry in clinical proton beams.

  6. SU-G-IeP2-10: Lens Dose Reduction by Patient Position Modification During Neck CT Exams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mosher, E; Lee, C; Butman, J

    Purpose: Irradiation of the lens during a neck CT may increase a patient’s risk of developing cataracts later in life. Radiologists and technologists at the National Institutes of Health Clinical Center (NIHCC) have developed new CT imaging protocols that include a reduction in scan range and modifying neck positioning using a head tilt. This study will evaluate the efficacy of this protocol in the reduction of lens dose. Methods: We retrieved CT images of five male patients who had two sets of CT images: before and after the implementation of the new protocol. The lens doses before the new protocolmore » were calculated using an in-house CT dose calculator, National Cancer Institute dosimetry system for CT (NCICT), where computational human phantoms with no head tilt are included. We also calculated the lens dose for the patient CT conducted after the new protocol by using an adult male computational phantom with the neck position deformed to match the angle of the head tilt. We also calculated the doses to other radiosensitive organs including the globes of the eye, brain, pituitary gland and salivary glands before and after head tilt. Results: Our dose calculations demonstrated that modifying neck position reduced dose to the lens by 89% on average (range: 86–96%). Globe, brain, pituitary and salivary gland doses also decreased by an average of 65% (51–95%), 38% (−8–66%), 34% (−43–84%) and 14% (13–14%), respectively. The new protocol resulted in a nearly ten-fold decrease in lens dose. Conclusion: The use of a head tilt and scan range reduction is an easy and effective method to reduce radiation exposure to the lens and other radiosensitive organs, while still allowing for the inclusion of critical neck structures in the CT image. We are expanding our study to a total of 10 males and 10 females.« less

  7. Natural radioactivity in soil in the Baluchistan province of Pakistan.

    PubMed

    Mujahid, S A; Hussain, S

    2010-08-01

    The measurements of natural radioactivity and the assessment of radiological hazards in the soil samples of Baluchistan province of Pakistan have been carried out using HPGe detector. The soil gas radon activities in these areas have also been measured using lucas cell technique. The measured activities of (226)Ra, (232)Th and (40)K were found in the range of 15-27, 20-37 and 328-648 Bq kg(-1), respectively. The calculated absorbed dose rate in air and the annual effective dose were in the range of 35-59 nGy h(-1) and 0.17-0.29 mSv, respectively. Radon activity in the soil gas was found in the range of 357-2476 Bq m(-3).

  8. Measurement of Individual Doses of Radiation by Personal Dosimeter Is Important for the Return of Residents from Evacuation Order Areas after Nuclear Disaster

    PubMed Central

    Orita, Makiko; Hayashida, Naomi; Taira, Yasuyuki; Fukushima, Yoshiko; Ide, Juichi; Endo, Yuuko; Kudo, Takashi; Yamashita, Shunichi; Takamura, Noboru

    2015-01-01

    To confirm the availability of individual dose evaluation for the return of residents after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FNPP), we evaluated individual doses of radiation as measured by personal dosimeters in residents who temporarily stayed in Evacuation Order Areas in Kawauchi village, which is partially located within a 20 km radius of the FNPP. We also compared individual doses with the external radiation doses estimated from the ambient dose rates and with doses estimated from the concentrations of radionuclides in the soil around each individual’s house. Individual doses were significantly correlated with the ambient doses in front of the entrances to the houses (r = 0.90, p<0.01), in the backyards (r = 0.41, p<0.01) and in the nearby fields (r = 0.80, p<0.01). The maximum cumulative ambient doses in the backyards and fields around the houses were 6.38 and 9.27 mSv/y, respectively. The maximum cumulative individual dose was 3.28 mSv/y, and the median and minimum doses were 1.35 and 0.71 mSv/y. The estimated external effective doses from concentrations of artificial radionuclides in soil samples ranged from 0.03 to 23.42 mSv/y. The individual doses were moderately correlated with external effective doses in the backyards (r = 0.38, p<0.01) and in the fields (r = 0.36, p<0.01); however, the individual doses were not significantly correlated with the external effective doses in front of the entrances (r = 0.01, p = 0.92). Our study confirmed that individual doses are low levels even in the evacuation order area in Kawauchi village, and external effective dose levels are certainly decreasing due to the decay of artificial radionuclides and the decontamination of contaminated soil. Long-term follow-up of individual doses as well as internal-exposure doses, environmental monitoring and reconstruction of infrastructure are needed so that residents may return to their hometowns after a nuclear disaster. PMID:25806523

  9. Measurement of individual doses of radiation by personal dosimeter is important for the return of residents from evacuation order areas after nuclear disaster.

    PubMed

    Orita, Makiko; Hayashida, Naomi; Taira, Yasuyuki; Fukushima, Yoshiko; Ide, Juichi; Endo, Yuuko; Kudo, Takashi; Yamashita, Shunichi; Takamura, Noboru

    2015-01-01

    To confirm the availability of individual dose evaluation for the return of residents after the accident at the Fukushima Dai-ichi Nuclear Power Plant (FNPP), we evaluated individual doses of radiation as measured by personal dosimeters in residents who temporarily stayed in Evacuation Order Areas in Kawauchi village, which is partially located within a 20 km radius of the FNPP. We also compared individual doses with the external radiation doses estimated from the ambient dose rates and with doses estimated from the concentrations of radionuclides in the soil around each individual's house. Individual doses were significantly correlated with the ambient doses in front of the entrances to the houses (r = 0.90, p<0.01), in the backyards (r = 0.41, p<0.01) and in the nearby fields (r = 0.80, p<0.01). The maximum cumulative ambient doses in the backyards and fields around the houses were 6.38 and 9.27 mSv/y, respectively. The maximum cumulative individual dose was 3.28 mSv/y, and the median and minimum doses were 1.35 and 0.71 mSv/y. The estimated external effective doses from concentrations of artificial radionuclides in soil samples ranged from 0.03 to 23.42 mSv/y. The individual doses were moderately correlated with external effective doses in the backyards (r = 0.38, p<0.01) and in the fields (r = 0.36, p<0.01); however, the individual doses were not significantly correlated with the external effective doses in front of the entrances (r = 0.01, p = 0.92). Our study confirmed that individual doses are low levels even in the evacuation order area in Kawauchi village, and external effective dose levels are certainly decreasing due to the decay of artificial radionuclides and the decontamination of contaminated soil. Long-term follow-up of individual doses as well as internal-exposure doses, environmental monitoring and reconstruction of infrastructure are needed so that residents may return to their hometowns after a nuclear disaster.

  10. SU-F-T-451: Doses to Organs-At-Risk in the Presence and Absence of a 1.5 T Magnetic Field for NSCLC Patients Undergoing SABR

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Al-Ward, S; Kim, A; McCann, C

    2016-06-15

    Purpose: To determine whether the electron return effect (ERE) has deleterious effects on lung SABR plans optimized in the presence of an orthogonal 1.5 T magnetic field. Methods: Data from five NSCLC-SABR patients were used. The Dose was modeled with a 2.5 mm dose grid in the presence and absence of a magnetic field using the Monaco (Elekta) TPS with the Monte Carlo GPUMCD (v5.1) algorithm. For each patient, two plans were generated, one using our conventional Elekta Agility linac beam model and another using the Elekta MRI Linac (MRL) model. Both plans were generated on the average CT usingmore » similar dose constraints and a 5 mm PTV. The optimization was performed using our clinic’s planning criteria, with normalization of the targets such that their V99% was equal to 99%. The OAR DVHs were compared for each patient. Results: The DVH plots revealed that there were limited differences when optimizing plans in the presence or absence of the magnetic field. The mean of the absolute differences, between the two planning types, in the equivalent uniform doses (EUDs) for the OARs were: 0.3 Gy (range of 0.0 - 1.0 Gy) for the esophagus, 0.6 Gy (range of 0.1 – 1.9 Gy) for the heart, 0.5 Gy (range of 0.2 – 0.8 Gy) for the lungs, and 0.6 Gy (range of 0.2 – 1.5 Gy) for the spinal canal. Regarding the maximum doses to the serial organs, the mean of the differences were 3.0 Gy (esophagus) and 0.9 Gy (spinal canal). No trends in the differences were observed. Conclusion: This study has demonstrated that there were no major differences between plans optimized using a conventional linac and those optimized using an MRI linac with an orthogonal 1.5 T magnetic field. This is attributed to the consideration of the ERE in the optimization. This project was made possible with the financial support of Elekta.« less

  11. Effects of electron beam irradiation on polyamide 12 with fiberglass reinforcement

    NASA Astrophysics Data System (ADS)

    Jeun, Joon-Pyo; Shin, Bum-Sik; Kim, Hyun-Bin; Nho, Young-Chang; Kang, Phil-Hyun

    2010-06-01

    In the present study, the effects of electron beam irradiation of polyamide 12 (PA12) with fiberglass reinforcement on the thermal and wear properties were investigated. Electron beam irradiation of PA 12 was carried out over a range of irradiation doses (100-600 kGy) in air. The gel formation in the presence of a curing agent was dependent on the radiation doses. The thermal properties of irradiated PA 12 were studied in the temperature region 50-250° C to observe the changes in the melting point with radiation dose. The dimensional stability was significantly increased by electron beam irradiation and the related crosslinking of the PA 12.

  12. Conformational Effects of UV Light on DNA Origami.

    PubMed

    Chen, Haorong; Li, Ruixin; Li, Shiming; Andréasson, Joakim; Choi, Jong Hyun

    2017-02-01

    The responses of DNA origami conformation to UV radiation of different wavelengths and doses are investigated. Short- and medium-wavelength UV light can cause photo-lesions in DNA origami. At moderate doses, the lesions do not cause any visible defects in the origami, nor do they significantly affect the hybridization capability. Instead, they help relieve the internal stress in the origami structure and restore it to the designed conformation. At high doses, staple dissociation increases which causes structural disintegration. Long-wavelength UV does not show any effect on origami conformation by itself. We show that this UV range can be used in conjunction with photoactive molecules for photo-reconfiguration, while avoiding any damage to the DNA structures.

  13. Behavioral effects of MDMA ('ecstasy') on adult zebrafish.

    PubMed

    Stewart, Adam; Riehl, Russell; Wong, Keith; Green, Jeremy; Cosgrove, Jessica; Vollmer, Karoly; Kyzar, Evan; Hart, Peter; Allain, Alexander; Cachat, Jonathan; Gaikwad, Siddharth; Hook, Molly; Rhymes, Kate; Newman, Alan; Utterback, Eli; Chang, Katie; Kalueff, Allan V

    2011-06-01

    3,4-methylenedioxymethamphetamine (MDMA, 'ecstasy') is a potent psychedelic drug inducing euphoria and hypersociability in humans, as well as hyperactivity and anxiety in rodents. Adult zebrafish (Danio rerio) have become a widely used species in neurobehavioral research. Here, we explore the effects of a wide range (0.25-120 mg/l) of acute MDMA doses on zebrafish behavior in the novel tank test. Although MDMA was inactive at lower doses (0.25-10 mg/l), higher doses reduced bottom swimming and immobility (40-120 mg/l) and impaired intrasession habituation (10-120 mg/l). MDMA also elevated brain c-fos expression, collectively confirming the usage of zebrafish models for screening of hallucinogenic compounds.

  14. Effects of electron beam irradiation on polyamide 12 with fiberglass reinforcement

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jeun, Joon-Pyo; Shin, Bum-Sik; Kim, Hyun-Bin

    2010-06-02

    In the present study, the effects of electron beam irradiation of polyamide 12 (PA12) with fiberglass reinforcement on the thermal and wear properties were investigated. Electron beam irradiation of PA 12 was carried out over a range of irradiation doses (100-600 kGy) in air. The gel formation in the presence of a curing agent was dependent on the radiation doses. The thermal properties of irradiated PA 12 were studied in the temperature region 50-250 deg. C to observe the changes in the melting point with radiation dose. The dimensional stability was significantly increased by electron beam irradiation and the relatedmore » crosslinking of the PA 12.« less

  15. Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT

    PubMed Central

    Dillman, Jonathan R.; Goodsitt, Mitchell M.; Christodoulou, Emmanuel G.; Keshavarzi, Nahid; Strouse, Peter J.

    2014-01-01

    Purpose To retrospectively compare image quality and radiation dose between a reduced-dose computed tomographic (CT) protocol that uses model-based iterative reconstruction (MBIR) and a standard-dose CT protocol that uses 30% adaptive statistical iterative reconstruction (ASIR) with filtered back projection. Materials and Methods Institutional review board approval was obtained. Clinical CT images of the chest, abdomen, and pelvis obtained with a reduced-dose protocol were identified. Images were reconstructed with two algorithms: MBIR and 100% ASIR. All subjects had undergone standard-dose CT within the prior year, and the images were reconstructed with 30% ASIR. Reduced- and standard-dose images were evaluated objectively and subjectively. Reduced-dose images were evaluated for lesion detectability. Spatial resolution was assessed in a phantom. Radiation dose was estimated by using volumetric CT dose index (CTDIvol) and calculated size-specific dose estimates (SSDE). A combination of descriptive statistics, analysis of variance, and t tests was used for statistical analysis. Results In the 25 patients who underwent the reduced-dose protocol, mean decrease in CTDIvol was 46% (range, 19%–65%) and mean decrease in SSDE was 44% (range, 19%–64%). Reduced-dose MBIR images had less noise (P > .004). Spatial resolution was superior for reduced-dose MBIR images. Reduced-dose MBIR images were equivalent to standard-dose images for lungs and soft tissues (P > .05) but were inferior for bones (P = .004). Reduced-dose 100% ASIR images were inferior for soft tissues (P < .002), lungs (P < .001), and bones (P < .001). By using the same reduced-dose acquisition, lesion detectability was better (38% [32 of 84 rated lesions]) or the same (62% [52 of 84 rated lesions]) with MBIR as compared with 100% ASIR. Conclusion CT performed with a reduced-dose protocol and MBIR is feasible in the pediatric population, and it maintains diagnostic quality. © RSNA, 2013 Online supplemental material is available for this article. PMID:24091359

  16. Is There a Dose-Response Relationship for Heart Disease With Low-Dose Radiation Therapy?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chung, Eugene; Corbett, James R.; Moran, Jean M.

    Purpose: To quantify cardiac radiation therapy (RT) exposure using sensitive measures of cardiac dysfunction; and to correlate dysfunction with heart doses, in the setting of adjuvant RT for left-sided breast cancer. Methods and Materials: On a randomized trial, 32 women with node-positive left-sided breast cancer underwent pre-RT stress single photon emission computed tomography (SPECT-CT) myocardial perfusion scans. Patients received RT to the breast/chest wall and regional lymph nodes to doses of 50 to 52.2 Gy. Repeat SPECT-CT scans were performed 1 year after RT. Perfusion defects (PD), summed stress defects scores (SSS), and ejection fractions (EF) were evaluated. Doses tomore » the heart and coronary arteries were quantified. Results: The mean difference in pre- and post-RT PD was −0.38% ± 3.20% (P=.68), with no clinically significant defects. To assess for subclinical effects, PD were also examined using a 1.5-SD below the normal mean threshold, with a mean difference of 2.53% ± 12.57% (P=.38). The mean differences in SSS and EF before and after RT were 0.78% ± 2.50% (P=.08) and 1.75% ± 7.29% (P=.39), respectively. The average heart Dmean and D95 were 2.82 Gy (range, 1.11-6.06 Gy) and 0.90 Gy (range, 0.13-2.17 Gy), respectively. The average Dmean and D95 to the left anterior descending artery were 7.22 Gy (range, 2.58-18.05 Gy) and 3.22 Gy (range, 1.23-6.86 Gy), respectively. No correlations were found between cardiac doses and changes in PD, SSS, and EF. Conclusions: Using sensitive measures of cardiac function, no clinically significant defects were found after RT, with the average heart Dmean <5 Gy. Although a dose response may exist for measures of cardiac dysfunction at higher doses, no correlation was found in the present study for low doses delivered to cardiac structures and perfusion, SSS, or EF.« less

  17. SU-E-T-280: Reconstructed Rectal Wall Dose Map-Based Verification of Rectal Dose Sparing Effect According to Rectum Definition Methods and Dose Perturbation by Air Cavity in Endo-Rectal Balloon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Park, J; Research Institute of Biomedical Engineering, The Catholic University of Korea, Seoul; Park, H

    Purpose: Dosimetric effect and discrepancy according to the rectum definition methods and dose perturbation by air cavity in an endo-rectal balloon (ERB) were verified using rectal-wall (Rwall) dose maps considering systematic errors in dose optimization and calculation accuracy in intensity-modulated radiation treatment (IMRT) for prostate cancer patients. Methods: When the inflated ERB having average diameter of 4.5 cm and air volume of 100 cc is used for patient, Rwall doses were predicted by pencil-beam convolution (PBC), anisotropic analytic algorithm (AAA), and AcurosXB (AXB) with material assignment function. The errors of dose optimization and calculation by separating air cavity from themore » whole rectum (Rwhole) were verified with measured rectal doses. The Rwall doses affected by the dose perturbation of air cavity were evaluated using a featured rectal phantom allowing insert of rolled-up gafchromic films and glass rod detectors placed along the rectum perimeter. Inner and outer Rwall doses were verified with reconstructed predicted rectal wall dose maps. Dose errors and extent at dose levels were evaluated with estimated rectal toxicity. Results: While AXB showed insignificant difference of target dose coverage, Rwall doses underestimated by up to 20% in dose optimization for the Rwhole than Rwall at all dose range except for the maximum dose. As dose optimization for Rwall was applied, the Rwall doses presented dose error less than 3% between dose calculation algorithm except for overestimation of maximum rectal dose up to 5% in PBC. Dose optimization for Rwhole caused dose difference of Rwall especially at intermediate doses. Conclusion: Dose optimization for Rwall could be suggested for more accurate prediction of rectal wall dose prediction and dose perturbation effect by air cavity in IMRT for prostate cancer. This research was supported by the Leading Foreign Research Institute Recruitment Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (MSIP) (Grant No. 200900420)« less

  18. On the use of volumetric-modulated arc therapy for single-fraction thoracic vertebral metastases stereotactic body radiosurgery

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pokhrel, Damodar, E-mail: damodar.pokhrel@uky.edu; Sood, Sumit; McClinton, Christopher

    To retrospectively evaluate quality, efficiency, and delivery accuracy of volumetric-modulated arc therapy (VMAT) plans for single-fraction treatment of thoracic vertebral metastases using image-guided stereotactic body radiosurgery (SBRS) after RTOG 0631 dosimetric compliance criteria. After obtaining credentialing for MD Anderson spine phantom irradiation validation, 10 previously treated patients with thoracic vertebral metastases with noncoplanar hybrid arcs using 1 to 2 3D-conformal partial arcs plus 7 to 9 intensity-modulated radiation therapy beams were retrospectively re-optimized with VMAT using 3 full coplanar arcs. Tumors were located between T2 and T12. Contrast-enhanced T1/T2-weighted magnetic resonance images were coregistered with planning computed tomography and planningmore » target volumes (PTV) were between 14.4 and 230.1 cc (median = 38.0 cc). Prescription dose was 16 Gy in 1 fraction with 6 MV beams at Novalis-TX linear accelerator consisting of micro multileaf collimators. Each plan was assessed for target coverage using conformality index, the conformation number, the ratio of the volume receiving 50% of the prescription dose over PTV, R50%, homogeneity index (HI), and PTV-1600 coverage per RTOG 0631 requirements. Organs-at-risk doses were evaluated for maximum doses to spinal cord (D{sub 0.03} {sub cc}, D{sub 0.35} {sub cc}), partial spinal cord (D{sub 10%}), esophagus (D{sub 0.03} {sub cc} and D{sub 5} {sub cc}), heart (D{sub 0.03} {sub cc} and D{sub 15} {sub cc}), and lung (V{sub 5}, V{sub 10}, and maximum dose to 1000 cc of lung). Dose delivery efficiency and accuracy of each VMAT-SBRS plan were assessed using quality assurance (QA) plan on MapCHECK device. Total beam-on time was recorded during QA procedure, and a clinical gamma index (2%/2 mm and 3%/3 mm) was used to compare agreement between planned and measured doses. All 10 VMAT-SBRS plans met RTOG 0631 dosimetric requirements for PTV coverage. The plans demonstrated highly conformal and homogenous coverage of the vertebral PTV with mean HI, conformality index, conformation number, and R{sub 50%} values of 0.13 ± 0.03 (range: 0.09 to 0.18), 1.03 ± 0.04 (range: 0.98 to 1.09), 0.81 ± 0.06 (range: 0.72 to 0.89), and 4.2 ± 0.94 (range: 2.7 to 5.4), respectively. All 10 patients met protocol guidelines with maximum dose to spinal cord (average: 8.83 ± 1.9 Gy, range: 5.9 to 10.9 Gy); dose to 0.35 cc of spinal cord (average: 7.62 ± 1.7 Gy, range: 5.4 to 9.6 Gy); and dose to 10% of partial spinal cord (average 6.31 ± 1.5 Gy, range: 3.5 to 8.5 Gy) less than 14, 10, and 10 Gy, respectively. For all 10 patients, the maximum dose to esophagus (average: 9.41 ± 4.3 Gy, range: 1.5 to 14.9 Gy) and dose to 5 cc of esophagus (average: 7.43 ± 3.8 Gy, range: 1.1 to 11.8 Gy) were kept less than protocol requirements 16 Gy and 11.9 Gy, respectively. In a similar manner, all 10 patients met protocol compliance criteria with maximum dose to heart (average: 4.62 ± 3.5 Gy, range: 1.3 to 10.2 Gy) and dose to 15 cc of heart (average: 2.23 ± 1.8 Gy, range: 0.3 to 5.6 Gy) less than 22 and 16 Gy, respectively. The dose to the lung was retained much lower than protocol guidelines for all 10 patients. The total number of monitor units was, on average, 6919 ± 1187. The average beam-on time was 11.5 ± 2.0 minutes. The VMAT plans demonstrated dose delivery accuracy of 95.8 ± 0.7%, on average, for clinical gamma passing rate with 2%/2 mm criteria and 98.3 ± 0.8%, on average, with 3%/3 mm criteria. All VMAT-SBRS plans were considered clinically acceptable per RTOG 0631 dosimetric compliance criteria. VMAT planning provided highly conformal and homogenous dose distributions for the lower-dose vertebral PTV and the spinal cord as well as organs-at-risk such as esophagus, heart, and lung. Higher QA pass rates and shorter beam-on time suggest that VMAT-SBRS is a clinically feasible, fast, and effective treatment option for patients with thoracic vertebral metastases.« less

  19. Repeat Gamma-Knife Radiosurgery for Refractory or Recurrent Trigeminal Neuralgia with Consideration About the Optimal Second Dose.

    PubMed

    Park, Seong-Cheol; Kwon, Do Hoon; Lee, Do Hee; Lee, Jung Kyo

    2016-02-01

    To investigate adequate radiation doses for repeat Gamma Knife radiosurgery (GKS) for trigeminal neuralgia in our series and meta-analysis. Fourteen patients treated by ipsilateral repeat GKS for trigeminal neuralgia were included. Median age of patients was 65 years (range, 28-78), the median target dose, 140-180). Patients were followed a median of 10.8 months (range, 1-151) after the second gamma-knife surgery. Brainstem dose analysis and vote-counting meta-analysis of 19 studies were performed. After the second gamma-knife radiosurgeries, pain was relieved effectively in 12 patients (86%; Barrow Neurological Institute Pain Intensity Score I-III). Post-gamma-knife radiosurgery trigeminal nerve deficits were mild in 5 patients. No serious anesthesia dolorosa was occurred. The second GKS radiation dose ≤ 60 Gy was significantly associated with worse pain control outcome (P = 0.018 in our series, permutation analysis of variance, and P = 0.009 in the meta-analysis, 2-tailed Fisher's exact test). Cumulative dose ≤ 140-150 Gy was significantly associated with poor pain control outcome (P = 0.033 in our series and P = 0.013 in the meta-analysis, 2-tailed Fisher's exact test). A cumulative brainstem edge dose >12 Gy tended to be associated with trigeminal nerve deficit (P = 0.077). Our study suggests that the second GKS dose is a potentially important factor. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Decreases in cocaine self-administration with dual inhibition of the dopamine transporter and σ receptors.

    PubMed

    Hiranita, Takato; Soto, Paul L; Kohut, Stephen J; Kopajtic, Theresa; Cao, Jianjing; Newman, Amy H; Tanda, Gianluigi; Katz, Jonathan L

    2011-11-01

    Sigma receptor (σR) antagonists attenuate many behavioral effects of cocaine but typically not its reinforcing effects in self-administration procedures. However, the σR antagonist rimcazole and its N-propylphenyl analogs, [3-(cis-3,5-dimethyl-4-[3-phenylpropyl]-1-piperazinyl)-propyl]diphenylamine hydrochloride (SH 3-24) and 9-[3-(cis-3,5-dimethyl-4-[3-phenylpropyl]-1-piperazinyl)-propyl]carbazole hydrobromide (SH 3-28), dose-dependently decreased the maximal rates of cocaine self-administration without affecting comparable responding maintained by food reinforcement. In contrast, a variety of σR antagonists [N-phenethylpiperidine oxalate (AC927), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(1-pyrrolidinyl)ethylamine dihydrobromide (BD 1008), N-[2-(3,4-dichlorophenyl)ethyl]-N-methyl-2-(dimethylamino) ethylamine dihydrobromide (BD 1047), N-[2-(3,4-dichlorophenyl) ethyl]-4-methylpiperazine dihydrochloride (BD 1063), and N,N-dipropyl-2-[4-methoxy-3-(2-phenylethoxy)phenyl]-ethylamine monohydrochloride (NE-100)] had no effect on cocaine self-administration across the range of doses that decreased rates of food-maintained responding. Rimcazole analogs differed from selective σR antagonists in their dual affinities for σRs and the dopamine transporter (DAT) assessed with radioligand binding. Selective DAT inhibitors and σR antagonists were studied alone and in combination on cocaine self-administration to determine whether actions at both σRs and the DAT were sufficient to reproduce the effects of rimcazole analogs. Typical DAT inhibitors [2β-carbomethoxy-3β-(4-fluorophenyl)tropane (WIN 35,428), methylphenidate, and nomifensine] dose-dependently shifted the cocaine dose-effect curve leftward. Combinations of DAT inhibitor and σR antagonist doses that were behaviorally inactive alone decreased cocaine self-administration without effects on food-maintained responding. In addition, whereas the DAT inhibitors were self-administered at rates similar to those of cocaine, neither rimcazole analogs nor typical σR antagonists (NE-100 and AC927) maintained responding above control levels across a wide range of doses. These findings suggest that the unique effects of rimcazole analogs are due to dual actions at the DAT and σRs and that a combined target approach may have utility in development of medical treatments for cocaine abuse.

  1. Intensity-modulated radiation therapy for pancreatic and prostate cancer using pulsed low–dose rate delivery techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Jie; Lang, Jinyi; Wang, Pei

    2014-01-01

    Reirradiation of patients who were previously treated with radiotherapy is vastly challenging. Pulsed low–dose rate (PLDR) external beam radiotherapy has the potential to reduce normal tissue toxicities while providing significant tumor control for recurrent cancers. This work investigates treatment planning techniques for intensity-modulated radiation therapy (IMRT)-based PLDR treatment of various sites, including cases with pancreatic and prostate cancer. A total of 20 patients with clinical recurrence were selected for this study, including 10 cases with pancreatic cancer and 10 with prostate cancer. Large variations in the target volume were included to test the ability of IMRT using the existing treatmentmore » planning system and optimization algorithm to deliver uniform doses in individual gantry angles/fields for PLDR treatments. Treatment plans were generated with 10 gantry angles using the step-and-shoot IMRT delivery technique, which can be delivered in 3-minute intervals to achieve an effective low dose rate of 6.7 cGy/min. Instead of dose constraints on critical structures, ring structures were mainly used in PLDR-IMRT optimization. In this study, the PLDR-IMRT plans were compared with the PLDR-3-dimensional conformal radiation therapy (3DCRT) plans and the PLDR-RapidArc plans. For the 10 cases with pancreatic cancer that were investigated, the mean planning target volume (PTV) dose for each gantry angle in the PLDR-IMRT plans ranged from 17.6 to 22.4 cGy. The maximum doses ranged between 22.9 and 34.8 cGy. The minimum doses ranged from 8.2 to 17.5 cGy. For the 10 cases with prostate cancer that were investigated, the mean PTV doses for individual gantry angles ranged from 18.8 to 22.6 cGy. The maximum doses per gantry angle were between 24.0 and 34.7 cGy. The minimum doses per gantry angle ranged from 4.4 to 17.4 cGy. A significant reduction in the organ at risk (OAR) dose was observed with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. The volume receiving an 18-Gy (V{sub 18}) dose for the left and right kidneys was reduced by 10.6% and 12.5%, respectively, for the pancreatic plans. The volume receiving a 45-Gy (V{sub 45}) dose for the small bowel decreased from 65.3% to 45.5%. For the cases with prostate cancer, the volume receiving a 40-Gy (V{sub 40}) dose for the bladder and the rectum was reduced significantly by 25.1% and 51.2%, respectively. When compared with the RapidArc technique, the volume receiving a 30-Gy (V{sub 30}) dose for the left and the right kidneys was lower in the IMRT plans. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. These results clearly demonstrated that the PLDR-IMRT plan was suitable for PLDR pancreatic and prostate cancer treatments in terms of the overall plan quality. A significant reduction in the OAR dose was achieved with the PLDR-IMRT plan when compared with that using the PLDR-3DCRT plan. For most OARs, no significant differences were observed between the PLDR-IMRT and the PLDR-RapidArc plans. When compared with the PLDR-3DCRT plan, the PLDR-IMRT plan could provide superior target coverage and normal tissue sparing for PLDR reirradiation of recurrent pancreatic and prostate cancers. The PLDR-IMRT plan is an effective treatment choice for recurrent cancers in most cancer centers.« less

  2. Assessment of the Technologies for Molecular Biodosimetry for Human Low-Dose Radiation Exposure Symposium: Agenda and Abstracts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coleman, Matthew A.; Ramakrishnan, Narayani

    In the event of a radiological accident, the rapid evaluation of the individual absorbed dose is paramount to discriminate those individuals who must receive medical attention. New research with genomic- and proteomic-wide tools is showing that within minutes to hours after exposure to ionizing radiation the cellular machinery is modified. For example: large-scale changes occur in the gene expression profiles involving a broad variety of cellular pathways after a wide range of both low dose (<10 cGy) and high dose (>10 cGy) ionizing radiation exposures. Symposium 12 was organized to address a wide range of biological effects using the latestmore » technologies. To address current models following ionizing radiation exposure, methods in biodosimetry and dose effects the symposia featured a general overview titled “Model Systems and Current Approaches in Biodosimetry” by Matthew A. Coleman, from Lawrence Livermore National Laboratory and a talk entitled “Brief Overview of Biodosimetry Projects in the NIH Rad/Nuc Program” by Dr. Narayani Ramakrishnan, National Institute of Allergy and Infectious Diseases. These two talk set the tone for issues in data and model integration as well as addressing the national need for robust technologies for biological dosimetry. The report continues with more description of the presentations, along with the agenda and abstracts of the papers presented.« less

  3. The plasma free amino acid dose-response technique: A proposed methodology for determining lysine relative bioavailability of rumen-protected lysine supplements.

    PubMed

    Whitehouse, N L; Schwab, C G; Brito, A F

    2017-12-01

    Estimates of Lys bioavailability of rumen-protected Lys (RP-Lys) supplements are often obtained using in vitro or 2-step in situ techniques, with little to no data determining efficacy and bioavailability in vivo. The objective of this study was to further evaluate and refine the use of the plasma free AA dose-response technique as a method for determining Lys relative bioavailability of RP-Lys supplements. Thirteen dose-response Latin square studies using 87 lactating, ruminally cannulated multiparous Holstein cows (days in milk from 55 to 315 and milk yield from 12 to 62 kg/d at the start of the studies) were conducted to measure the relative bioavailability of RP-Lys supplements. Intestinal (1 study) and abomasal (12 studies) infusions of Lys ranged from 0 to 84 g/d, and experimental periods ranged from 4 to 21 d. Basal diets were formulated to be adequate in metabolizable Met, but varied in predicted metabolizable Lys (5.04 to 6.81% of metabolizable protein). One to 4 daily blood samples were taken from the coccygeal vessels for 1 to 3 consecutive days in each period. Plasma Lys concentration in cows assigned to the control treatment (0 g/d Lys) ranged from 1.83 to 5.21% of total plasma AA, whereas that from cows duodenally or abomasally infused with Lys ranged from 2.53 to 7.51% of total plasma AA. Results from studies involving more than 2 amounts of infused Lys confirmed linearity of response. The following variables were regressed against the plasma Lys dose-response slopes generated from the Lys infusion treatments to examine their effects on the magnitude of the slopes: plasma Lys concentration of the control diet, plasma Lys concentration at the greatest amount of infused Lys, net energy of lactation and metabolizable protein balances, metabolizable protein supply, days in milk, milk yield, milk concentrations of fat, true protein, and lactose, milk true protein yield, and dry matter intake. The variable having the greatest effect on the magnitude of the dose-response slope was the plasma Lys concentration at the greatest amount infused. The relative bioavailability of evaluated RP-Lys supplements using the plasma free AA dose-response technique ranged from 5 to 87%. It was concluded that plasma free Lys increases in a linear fashion to increasing amounts of absorbed Lys and that the dose-response technique is an appropriate technique for evaluating RP-Lys supplements. Copyright © 2017 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  4. Carbon-ion re-irradiation for recurrences after initial treatment of stage I non-small cell lung cancer with carbon-ion radiotherapy.

    PubMed

    Karube, Masataka; Yamamoto, Naoyoshi; Tsuji, Hiroshi; Kanematsu, Nobuyuki; Nakajima, Mio; Yamashita, Hideomi; Nakagawa, Keiichi; Kamada, Tadashi

    2017-10-01

    To investigate carbon-ion radiotherapy (CIRT) for in-field recurrence of stage I non-small cell lung cancer (NSCLC) initially treated with CIRT. From January 2007 to March 2014, patients initially treated for stage I NSCLC with CIRT and relapsed in-field were candidates. Overall survival (OS) rate, local control (LC) rate, progressive free survival (PFS) rate, dose to the lungs and skin, and adverse effects were analyzed. Twenty-nine patients were eligible. Median age at re-irradiation was 74years (range 53-90). Median observation period from the first day of re-irradiation was 29months (4-88months). Median prescribed dose was 46.0Gy (RBE) as initial treatment and 66.0Gy (RBE) in 12 fractions as re-irradiation. Two-year OS, LC, and PFS rates after re-irradiation were 69.0% (95% CI: 50.3-83.0), 66.9% (95% CI: 47.5-81.9), and 51.7% (95% CI: 34.1-68.9). Median skin maximum dose was 53.8Gy (RBE) (range 4.4-103.1) and median of mean lung dose was 7.3Gy (RBE) (range 2.6-14.0). There were no severer than grade 2 adverse effects except one (3.4%) grade 3 bacterial pneumonia, which was not considered radiation-induced. CIRT for stage I NSCLC local recurrence is an acceptable definitive re-treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Optimization of exposure parameters for pediatric chest x-ray imaging

    NASA Astrophysics Data System (ADS)

    Park, Hye-Suk; Kim, Ye-Seul; Kim, Hee-Joung

    2012-03-01

    The pediatric patients are more susceptible to the effects of ionizing radiation than adults. Pediatric patients are smaller, more radiosensitive than adult patients and many cannot stand unassisted. Their characteristics affect the method of imaging projection and how dose is optimized. The purpose of this study was to investigate the effect of various technical parameters for the dose optimization in pediatric chest radiological examinations by evaluating effective dose and effective detective quantum efficiency (eDQE) including the scatter radiation from the object, the blur caused by the focal spot, geometric magnification and detector characteristics. For the tube voltages ranging from 40 to 90 kV in 10 kV increments at the focus-to-detector distance of 100, 110, 120, 150, 180 cm, the eDQE was evaluated at same effective dose. The results showed that the eDQE was largest at 60 kVp without and with an anti-scatter grid. Especially, the eDQE was considerably higher without the use of an anti-scatter grid on equivalent effective dose. This indicates that the reducing the scatter radiation did not compensate for the loss of absorbed effective photons in the grid. When the grid is not used the eDQE increased with increasing focus-to-detector distance because of the greater effective modulation transfer function (eMTF) with the lower focal spot blurring. In conclusion, for pediatric patients, the amount of scattered radiation is less, and the amount of grid attenuation increased unnecessary radiation dose.

  6. [Comparison of Organ Dose Calculation Using Monte Carlo Simulation and In-phantom Dosimetry in CT Examination].

    PubMed

    Iriuchijima, Akiko; Fukushima, Yasuhiro; Ogura, Akio

    Direct measurement of each patient organ dose from computed tomography (CT) is not possible. Most methods to estimate patient organ dose is using Monte Carlo simulation with dedicated software. However, the method and the relative differences between organ dose simulation and measurement is unclear. The purpose of this study was to compare organ doses evaluated by Monte Carlo simulation with doses evaluated by in-phantom dosimetry. The simulation software Radimetrics (Bayer) was used for the calculation of organ dose. Measurement was performed with radio-photoluminescence glass dosimeter (RPLD) set at various organ positions within RANDO phantom. To evaluate difference of CT scanner, two different CT scanners were used in this study. Angular dependence of RPLD and measurement of effective energy were performed for each scanner. The comparison of simulation and measurement was evaluated by relative differences. In the results, angular dependence of RPLD at two scanners was 31.6±0.45 mGy for SOMATOM Definition Flash and 29.2±0.18 mGy for LightSpeed VCT. The organ dose was 42.2 mGy (range, 29.9-52.7 mGy) by measurements and 37.7 mGy (range, 27.9-48.1 mGy) by simulations. The relative differences of organ dose between measurement and simulation were 13%, excluding of breast's 42%. We found that organ dose by simulation was lower than by measurement. In conclusion, the results of relative differences will be useful for evaluating organ doses for individual patients by simulation software Radimetrics.

  7. SU-F-T-22: Clinical Implications When Using TG-186 (ACE) Heterogeneity Software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Likhacheva, A; Grade, E; Sadeghi, A

    Purpose: The purpose of this study is to compare dosimetric calculations using traditional TG-43 formalism and Oncentra Brachy Advanced Collapsed cone Engine (ACE) TG-186 calculation algorithm in clinical setting. Methods: We analyzed dosimetry of four patients treated with accelerated partial breast irradiation using a multi-channel intracavitary device (SAVI). All patients were treated to 34 Gy in 10 fractions using a high-dose-rate (192) Ir source. The plans were designed and treated using the TG-43 model. ACE was used to assess the effect heterogeneity correction on various dosimetric parameters. Mass density was estimated using Hounsfield units. Results: Compared to TG-43 formalism, ACEmore » estimated lower doses to targets and organs at risk. The mean difference was 19.8% (range 15.3–24.1%) for PTV-eval V200, 12.0% (range 9.7–17.7%) for PTV-eval V150, 4.3% (range 3.3–6.5%) for PTV-eval D95, 3.3% (range 1.4–5.4%) for PTV-eval D90, 5.4% (range 2.9–9.9%) for maximum rib dose, and 5.7% (2.4–7.4%) for maximum skin dose. There was no correlation between the magnitude of the difference and the PTV-eval volume, air volume, or tissue-applicator conformance. Conclusion: Based on our preliminary study, the TG-43 algorithm appears to overestimate the dose to targets and organs at risk when compared to the ACE TG-186 software. We hypothesize that air adjacent to the SAVI struts contributes to lack of scatter thereby contributing a significant difference in dose calculation when using ACE. We believe that ACE calculation provides a more realistic isodose distribution than TG-43. We plan to further investigate the impact of heterogeneity correction on brachytherapy planning for a wide variety of clinical scenarios, include skin, cervix/uterus, prostate, and lung.« less

  8. Clinical pharmacology of AMG 181, a gut-specific human anti-α4β7 monoclonal antibody, for treating inflammatory bowel diseases

    PubMed Central

    Pan, Wei-Jian; Köck, Kathleen; Rees, William A; Sullivan, Barbara A; Evangelista, Christine M; Yen, Mark; Andrews, Jane M; Radford-Smith, Graham L; Prince, Peter J; Reynhardt, Kaz O; Doherty, David R; Patel, Sonal K; Krill, Christine D; Zhou, Kefei; Shen, Jing; Smith, Lynn E; Gow, Jason M; Lee, Jonathan; Treacy, Anthony M; Yu, Zhigang; Platt, Virginia M; Borie, Dominic C

    2014-01-01

    Aims AMG 181 pharmacokinetics/pharmacodynamics (PK/PD), safety, tolerability and effects after single subcutaneous (s.c.) or intravenous (i.v.) administration were evaluated in a randomized, double-blind, placebo-controlled study. Methods Healthy male subjects (n= 68) received a single dose of AMG 181 or placebo at 0.7, 2.1, 7, 21, 70 mg s.c. (or i.v.), 210 mg s.c. (or i.v.), 420 mg i.v. or placebo. Four ulcerative colitis (UC) subjects (n= 4, male : female 2:2) received 210 mg AMG 181 or placebo s.c. (3:1). AMG 181 concentration, anti-AMG 181-antibody (ADA), α4β7 receptor occupancy (RO), target cell counts, serum C-reactive protein, fecal biomarkers and Mayo score were measured. Subjects were followed 3–9 months after dose. Results Following s.c. dosing, AMG 181 was absorbed with a median tmax ranging between 2–10 days and a bioavailability between 82% and 99%. Cmax and AUC increased dose-proportionally and approximately dose-proportionally, respectively, within the 70–210 mg s.c. and 70–420 mg i.v. ranges. The linear β-phase t1/2 was 31 (range 20–48) days. Target-mediated disposition occurred at serum AMG 181 concentrations of less than 1 μg ml−1. The PD effect on α4β7 RO showed an EC50 of 0.01 μg ml−1. Lymphocytes, eosinophils, CD4+ T cells and subset counts were unchanged. AMG 181-treated UC subjects were in remission with mucosal healing at weeks 6, 12 and/or 28. The placebo-treated UC subject experienced colitis flare at week 6. No ADA or AMG 181 treatment-related serious adverse events were observed. Conclusions AMG 181 has PK/PD, safety, and effect profiles suitable for further testing in subjects with inflammatory bowel diseases. PMID:24803302

  9. Effect of Laser Therapy on Chronic Osteoarthritis of the Knee in Older Subjects

    PubMed Central

    Youssef, Enas Fawzey; Muaidi, Qassim Ibrahim; Shanb, Alsayed Abdelhameed

    2016-01-01

    Introduction: Osteoarthritis (OA) is a common degenerative joint disease particularly in older subjects. It is usually associated with pain, restricted range of motion, muscle weakness, difficulties in daily living activities and impaired quality of life. To determine the effects of adding two different intensities of low-level laser therapy (LLLT) to exercise training program on pain severity, joint stiffness, physical function, isometric muscle strength, range of motion of the knee, and quality of life in older subjects with knee OA. Methods: Patients were randomly assigned into three groups. They received 16 sessions, 2 sessions/week for 8 weeks. Group-I: 18 patients were treated with a laser dose of 6 J/cm2 with a total dose of 48 J. Group-II: 18 patients were treated with a laser dose of 3 J/cm2 with a total dose of 27 J. Group-III: 15 patients were treated with laser without emission as a placebo. All patients received same exercise training program including stretching and strengthening exercises. Patients were evaluated before and after intervention by visual analogue scale (VAS), the Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index for quality of life, handheld dynamometer and universal goniometer. Results: T test revealed that there was a significant reduction in VAS and pain intensity, an increase in isometric muscle strength and range of motion of the knee as well as increase in physical functional ability in three treatment groups. Also analysis of variance (ANOVA) proved significant differences among them and the post hoc tests (LSD) test showed the best improvements for patients of the first group. Conclusion: It can be concluded that addition of LLLT to exercise training program is more effective than exercise training alone in the treatment of older patients with chronic knee OA and the rate of improvement may be dose dependent, as with 6 J/cm2 or 3 J/cm2. PMID:27330707

  10. SU-E-I-57: Evaluation and Optimization of Effective-Dose Using Different Beam-Hardening Filters in Clinical Pediatric Shunt CT Protocol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gill, K; Aldoohan, S; Collier, J

    Purpose: Study image optimization and radiation dose reduction in pediatric shunt CT scanning protocol through the use of different beam-hardening filters Methods: A 64-slice CT scanner at OU Childrens Hospital has been used to evaluate CT image contrast-to-noise ratio (CNR) and measure effective-doses based on the concept of CT dose index (CTDIvol) using the pediatric head shunt scanning protocol. The routine axial pediatric head shunt scanning protocol that has been optimized for the intrinsic x-ray tube filter has been used to evaluate CNR by acquiring images using the ACR approved CT-phantom and radiation dose CTphantom, which was used to measuremore » CTDIvol. These results were set as reference points to study and evaluate the effects of adding different filtering materials (i.e. Tungsten, Tantalum, Titanium, Nickel and Copper filters) to the existing filter on image quality and radiation dose. To ensure optimal image quality, the scanner routine air calibration was run for each added filter. The image CNR was evaluated for different kVps and wide range of mAs values using above mentioned beam-hardening filters. These scanning protocols were run under axial as well as under helical techniques. The CTDIvol and the effective-dose were measured and calculated for all scanning protocols and added filtration, including the intrinsic x-ray tube filter. Results: Beam-hardening filter shapes energy spectrum, which reduces the dose by 27%. No noticeable changes in image low contrast detectability Conclusion: Effective-dose is very much dependent on the CTDIVol, which is further very much dependent on beam-hardening filters. Substantial reduction in effective-dose is realized using beam-hardening filters as compare to the intrinsic filter. This phantom study showed that significant radiation dose reduction could be achieved in CT pediatric shunt scanning protocols without compromising in diagnostic value of image quality.« less

  11. Patient-based estimation of organ dose for a population of 58 adult patients across 13 protocol categories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sahbaee, Pooyan, E-mail: psahbae@ncsu.edu; Segars, W. Paul; Samei, Ehsan

    2014-07-15

    Purpose: This study aimed to provide a comprehensive patient-specific organ dose estimation across a multiplicity of computed tomography (CT) examination protocols. Methods: A validated Monte Carlo program was employed to model a common CT system (LightSpeed VCT, GE Healthcare). The organ and effective doses were estimated from 13 commonly used body and neurological CT examination. The dose estimation was performed on 58 adult computational extended cardiac-torso phantoms (35 male, 23 female, mean age 51.5 years, mean weight 80.2 kg). The organ dose normalized by CTDI{sub vol} (h factor) and effective dose normalized by the dose length product (DLP) (k factor)more » were calculated from the results. A mathematical model was derived for the correlation between the h and k factors with the patient size across the protocols. Based on this mathematical model, a dose estimation iPhone operating system application was designed and developed to be used as a tool to estimate dose to the patients for a variety of routinely used CT examinations. Results: The organ dose results across all the protocols showed an exponential decrease with patient body size. The correlation was generally strong for the organs which were fully or partially located inside the scan coverage (Pearson sample correlation coefficient (r) of 0.49). The correlation was weaker for organs outside the scan coverage for which distance between the organ and the irradiation area was a stronger predictor of dose to the organ. For body protocols, the effective dose before and after normalization by DLP decreased exponentially with increasing patient's body diameter (r > 0.85). The exponential relationship between effective dose and patient's body diameter was significantly weaker for neurological protocols (r < 0.41), where the trunk length was a slightly stronger predictor of effective dose (0.15 < r < 0.46). Conclusions: While the most accurate estimation of a patient dose requires specific modeling of the patient anatomy, a first order approximation of organ and effective doses from routine CT scan protocols can be reasonably estimated using size specific factors. Estimation accuracy is generally poor for organ outside the scan range and for neurological protocols. The dose calculator designed in this study can be used to conveniently estimate and report the dose values for a patient across a multiplicity of CT scan protocols.« less

  12. Internal dose assessment of 210Po using biokinetic modeling and urinary excretion measurement.

    PubMed

    Li, Wei Bo; Gerstmann, Udo; Giussani, Augusto; Oeh, Uwe; Paretzke, Herwig G

    2008-02-01

    The mysterious death of Mr. Alexander Litvinenko who was most possibly poisoned by Polonium-210 ((210)Po) in November 2006 in London attracted the attention of the public to the kinetics, dosimetry and the risk of this high radiotoxic isotope in the human body. In the present paper, the urinary excretion of seven persons who were possibly exposed to traces of (210)Po was monitored. The values measured in the GSF Radioanalytical Laboratory are in the range of natural background concentration. To assess the effective dose received by those persons, the time-dependence of the organ equivalent dose and the effective dose after acute ingestion and inhalation of (210)Po were calculated using the biokinetic model for polonium (Po) recommended by the International Commission on Radiological Protection (ICRP) and the one recently published by Leggett and Eckerman (L&E). The daily urinary excretion to effective dose conversion factors for ingestion and inhalation were evaluated based on the ICRP and L&E models for members of the public. The ingestion (inhalation) effective dose per unit intake integrated over one day is 1.7 x 10(-8) (1.4 x 10(-7)) Sv Bq(-1), 2.0 x 10(-7) (9.6 x 10(-7)) Sv Bq(-1) over 10 days, 5.2 x 10(-7) (2.0 x 10(-6)) Sv Bq(-1) over 30 days and 1.0 x 10(-6) (3.0 x 10(-6)) Sv Bq(-1) over 100 days. The daily urinary excretions after acute ingestion (inhalation) of 1 Bq of (210)Po are 1.1 x 10(-3) (1.0 x 10(-4)) on day 1, 2.0 x 10(-3) (1.9 x 10(-4)) on day 10, 1.3 x 10(-3) (1.7 x 10(-4)) on day 30 and 3.6 x 10(-4) (8.3 x 10(-5)) Bq d(-1) on day 100, respectively. The resulting committed effective doses range from 2.1 x 10(-3) to 1.7 x 10(-2) mSv by an assumption of ingestion and from 5.5 x 10(-2) to 4.5 x 10(-1) mSv by inhalation. For the case of Mr. Litvinenko, the mean organ absorbed dose as a function of time was calculated using both the above stated models. The red bone marrow, the kidneys and the liver were considered as the critical organs. Assuming a value of lethal absorbed dose of 5 Gy to the bone marrow, 6 Gy to the kidneys and 8 Gy to the liver, the amount of (210)Po which Mr. Litvinenko might have ingested is therefore estimated to range from 27 to 1,408 MBq, i.e 0.2-8.5 microg, depending on the modality of intake and on different assumptions about blood absorption.

  13. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dynan, William S.

    The goal of the project was to determine whether high linear energy transfer (LET) space radiation produces the same or different effects as low doses of terrestrial (low-LET) radiation. The work used the Japanese medaka fish (Oryzias latipes) as a vertebrate model organism that can be maintained in large numbers at low cost for lifetime studies. To determine whether simulated space radiation produced the same or different effects as low doses of low-LET radiation, medaka embryos were irradiated at doses ranging from 0.1 to 9 Gray (Gy) of high-LET charged particle radiation (1000 MeV/nucleon 56-Fe ions) or 0.1 Gy tomore » 27 Gy of low-LET gamma-rays. To examine the effect of irradiation on potential biomarkers, the population was sampled at intervals from 8 to 28 months post-irradiation and liver tissue was subjected to histological and molecular analysis. Charged particle radiation and aging contributed synergistically to accumulation of lipid oxidation products, which are a marker of chronic oxidative stress. This was mirrored by a decline in mRNA encoding the transcriptional activator PPARGC1A, which is required for mitochondrial maintenance and for defense against oxidative stress. Additionally, mitochondria had an elongated and enlarged ultrastructure. Depending on the endpoint, effects of gamma-rays in the same dose range were either lesser or not detected. Together, results indicate that a single exposure to high-LET, but not low-LET radiation, early in life, leads to increased oxidative stress throughout the normal lifespan of the individual.« less

  14. Sildenafil exposure and hemodynamic effect after stage II single-ventricle surgery

    PubMed Central

    Hill, Kevin D.; Tunks, Robert D.; Barker, Piers C. A.; Benjamin, Daniel K.; Cohen-Wolkowiez, Michael; Fleming, Gregory A.; Laughon, Matthew; Li, Jennifer S.

    2013-01-01

    Objective To determine sildenafil exposure and hemodynamic effect in children after stage II single-ventricle surgery. Design Prospective, dose escalation trial. Setting Single-center, pediatric catheterization laboratory. Patients 12 children post stage II single-ventricle surgical palliation and undergoing elective cardiac catheterization: median age 1.9 years (range: 0.8, 4.0), weight 11 kg (8, 13), 9 females, and 10 with a single right ventricle. Interventions Catheterization and echocardiography performed before and immediately after single-dose intravenous sildenafil (0.125, 0.25, 0.35, or 0.45 mg/kg over 20 minutes). Measurements Peak sildenafil and des-methyl sildenafil concentration, change in hemodynamic parameters measured by cardiac catheterization and echocardiography including indexed pulmonary vascular resistance, and myocardial performance. Main Results Maximum sildenafil concentrations ranged from 92–775 ng/ml and were above the in vitro threshold needed for 77% phosphodiesterase type-5 (PDE-5) inhibition in 80% of subjects and 90% inhibition in 80% of subjects with doses ≥0.35 mg/kg. Sildenafil lowered pulmonary vascular resistance index (PVRI) in all 12 subjects (median PVRI 2.2 [range: 1.6, 7.9]; decreased to 1.7 [1.2, 5.4] WU x m2; p<0.01) with no dose-response effect. Sildenafil improved pulmonary blood flow (+8% [0, 20], p=0.04) and saturations (+2% [0, 16], p=0.04) in those with baseline PVRI ≥2 WU x m2 (n=7). Change in saturations correlated inversely with change in PVRI (r2 = 0.74 p<0.01). Sildenafil also lowered mean blood pressure (−12% [−20, +10]; p=0.04). There was no change in cardiac index and no effect on myocardial performance. There were no adverse events. Conclusions Sildenafil demonstrated non-linear exposure with high inter-individual variability but was well tolerated and effectively lowered PVRI in all subjects. Sildenafil did not acutely improve myocardial performance or increase cardiac index. PMID:23823195

  15. Country specific predictions of the cost-effectiveness of malaria vaccine RTS,S/AS01 in endemic Africa.

    PubMed

    Galactionova, Katya; Tediosi, Fabrizio; Camponovo, Flavia; Smith, Thomas A; Gething, Peter W; Penny, Melissa A

    2017-01-03

    RTS,S/AS01 is a safe and moderately efficacious vaccine considered for implementation in endemic Africa. Model predictions of impact and cost-effectiveness of this new intervention could aid in country adoption decisions. The impact of RTS,S was assessed in 43 countries using an ensemble of models of Plasmodium falciparum epidemiology. Informed by the 32months follow-up data from the phase 3 trial, vaccine effectiveness was evaluated at country levels of malaria parasite prevalence, coverage of control interventions and immunization. Benefits and costs of the program incremental to routine malaria control were evaluated for a four dose schedule: first dose administered at six months, second and third - before 9months, and fourth dose at 27months of age. Sensitivity analyses around vaccine properties, transmission, and economic inputs were conducted. If implemented in all 43 countries the vaccine has the potential to avert 123 (117;129) million malaria episodes over the first 10years. Burden averted averages 18,413 (range of country median estimates 156-40,054) DALYs per 100,000 fully vaccinated children with much variation across settings primarily driven by differences in transmission intensity. At a price of $5 per dose program costs average $39.8 per fully vaccinated child with a median cost-effectiveness ratio of $188 (range $78-$22,448) per DALY averted; the ratio is lower by one third - $136 (range $116-$220) - in settings where parasite prevalence in children aged 2-10years is at or above 10%. RTS,S/AS01has the potential to substantially reduce malaria burden in children across Africa. Conditional on assumptions on price, coverage, and vaccine properties, adding RTS,S to routine malaria control interventions would be highly cost-effective. Implementation decisions will need to further consider feasibility of scaling up existing control programs, and operational constraints in reaching children at risk with the schedule. Copyright © 2016 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  16. How flatbed scanners upset accurate film dosimetry

    NASA Astrophysics Data System (ADS)

    van Battum, L. J.; Huizenga, H.; Verdaasdonk, R. M.; Heukelom, S.

    2016-01-01

    Film is an excellent dosimeter for verification of dose distributions due to its high spatial resolution. Irradiated film can be digitized with low-cost, transmission, flatbed scanners. However, a disadvantage is their lateral scan effect (LSE): a scanner readout change over its lateral scan axis. Although anisotropic light scattering was presented as the origin of the LSE, this paper presents an alternative cause. Hereto, LSE for two flatbed scanners (Epson 1680 Expression Pro and Epson 10000XL), and Gafchromic film (EBT, EBT2, EBT3) was investigated, focused on three effects: cross talk, optical path length and polarization. Cross talk was examined using triangular sheets of various optical densities. The optical path length effect was studied using absorptive and reflective neutral density filters with well-defined optical characteristics (OD range 0.2-2.0). Linear polarizer sheets were used to investigate light polarization on the CCD signal in absence and presence of (un)irradiated Gafchromic film. Film dose values ranged between 0.2 to 9 Gy, i.e. an optical density range between 0.25 to 1.1. Measurements were performed in the scanner’s transmission mode, with red-green-blue channels. LSE was found to depend on scanner construction and film type. Its magnitude depends on dose: for 9 Gy increasing up to 14% at maximum lateral position. Cross talk was only significant in high contrast regions, up to 2% for very small fields. The optical path length effect introduced by film on the scanner causes 3% for pixels in the extreme lateral position. Light polarization due to film and the scanner’s optical mirror system is the main contributor, different in magnitude for the red, green and blue channel. We concluded that any Gafchromic EBT type film scanned with a flatbed scanner will face these optical effects. Accurate dosimetry requires correction of LSE, therefore, determination of the LSE per color channel and dose delivered to the film.

  17. Acute toxicity of subcutaneously administered vitamin E isomers delta- and gamma-tocotrienol in mice.

    PubMed

    Swift, Sibyl N; Pessu, Roli L; Chakraborty, Kushal; Villa, Vilmar; Lombardini, Eric; Ghosh, Sanchita P

    2014-01-01

    The toxicity of parenterally administered vitamin E isomers, delta-tocotrienol (DT3) and gamma-tocotrienol (GT3), was evaluated in male and female CD2F1 mice. In an acute toxicity study, a single dose of DT3 or GT3 was administered subcutaneously in a dose range of 200 to 800 mg/kg. A mild to moderately severe dermatitis was observed clinically and microscopically in animals at the injection site at doses above 200 mg/kg. The severity of the reaction was reduced when the drug concentration was lowered. Neither drug produced detectable toxic effects in any other tissue at the doses tested. Based on histopathological analysis for both DT3 and GT3, and macroscopic observations of inflammation at the injection site, a dose of 300 mg/kg was selected as the lowest toxic dose in a 30-day toxicity study performed in male mice. At this dose, a mild skin irritation occurred at the injection site that recovered completely by the end of the experimental period. At a dose of 300 mg/kg of DT3 or GT3, no adverse effects were observed in any tissues or organs. © The Author(s) 2014.

  18. Activation of D2 autoreceptors alters cocaine-induced locomotion and slows down local field oscillations in the rat ventral tegmental area.

    PubMed

    Koulchitsky, Stanislav; Delairesse, Charlotte; Beeken, Thom; Monteforte, Alexandre; Dethier, Julie; Quertemont, Etienne; Findeisen, Rolf; Bullinger, Eric; Seutin, Vincent

    2016-09-01

    Psychoactive substances affecting the dopaminergic system induce locomotor activation and, in high doses, stereotypies. Network mechanisms underlying the shift from an active goal-directed behavior to a "seemingly purposeless" stereotypic locomotion remain unclear. In the present study we sought to determine the relationships between the behavioral effects of dopaminergic drugs and their effects on local field potentials (LFPs), which were telemetrically recorded within the ventral tegmental area (VTA) of freely moving rats. We used the D2/D3 agonist quinpirole in a low, autoreceptor-selective (0.1 mg/kg, i.p.) and in a high (0.5 mg/kg, i.p.) dose, and a moderate dose of cocaine (10 mg/kg, i.p.). In the control group, power spectrum analysis revealed a prominent peak of LFP power in the theta frequency range during active exploration. Cocaine alone stimulated locomotion, but had no significant effect on the peak of the LFP power. In contrast, co-administration of low dose quinpirole with cocaine markedly altered the pattern of locomotion, from goal-directed exploratory behavior to recurrent motion resembling locomotor stereotypy. This behavioral effect was accompanied by a shift of the dominant theta power toward a significantly lower (by ∼15%) frequency. High dose quinpirole also provoked an increased locomotor activity with signs of behavioral stereotypies, and also induced a shift of the dominant oscillation frequency toward the lower range. These results demonstrate a correlation between the LFP oscillation frequency within the VTA and a qualitative aspect of locomotor behavior, perhaps due to a variable level of coherence of this region with its input or output areas. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Nicotinic alpha 7 receptor agonists EVP-6124 and BMS-933043, attenuate scopolamine-induced deficits in visuo-spatial paired associates learning.

    PubMed

    Weed, Michael R; Polino, Joseph; Signor, Laura; Bookbinder, Mark; Keavy, Deborah; Benitex, Yulia; Morgan, Daniel G; King, Dalton; Macor, John E; Zaczek, Robert; Olson, Richard; Bristow, Linda J

    2017-01-01

    Agonists at the nicotinic acetylcholine alpha 7 receptor (nAChR α7) subtype have the potential to treat cognitive deficits in patients with Alzheimer's disease (AD) or schizophrenia. Visuo-spatial paired associates learning (vsPAL) is a task that has been shown to reliably predict conversion from mild cognitive impairment to AD in humans and can also be performed by nonhuman primates. Reversal of scopolamine-induced impairment of vsPAL performance may represent a translational approach for the development of nAChR α7 agonists. The present study investigated the effect of treatment with the acetylcholinesterase inhibitor, donepezil, or three nAChR α7 agonists, BMS-933043, EVP-6124 and RG3487, on vsPAL performance in scopolamine-treated cynomolgus monkeys. Scopolamine administration impaired vsPAL performance accuracy in a dose- and difficulty- dependent manner. The impairment of eventual accuracy, a measure of visuo-spatial learning during the task, was significantly ameliorated by treatment with donepezil (0.3 mg/kg, i.m.), EVP-6124 (0.01 mg/kg, i.m.) or BMS-933043 (0.03, 0.1 and 0.3 mg/kg, i.m.). Both nAChR α7 agonists showed inverted-U shaped dose-effect relationships with EVP-6124 effective at a single dose only whereas BMS-933043 was effective across at least a 10 fold dose/exposure range. RG3487 was not efficacious in this paradigm at the dose range examined (0.03-1 mg/kg, i.m.). These results are the first demonstration that the nAChR α7 agonists, EVP-6124 and BMS-933043, can ameliorate scopolamine-induced cognitive deficits in nonhuman primates performing the vsPAL task.

  20. Nicotinic alpha 7 receptor agonists EVP-6124 and BMS-933043, attenuate scopolamine-induced deficits in visuo-spatial paired associates learning

    PubMed Central

    Polino, Joseph; Signor, Laura; Bookbinder, Mark; Keavy, Deborah; Benitex, Yulia; Morgan, Daniel G.; King, Dalton; Macor, John E.; Zaczek, Robert; Olson, Richard; Bristow, Linda J.

    2017-01-01

    Agonists at the nicotinic acetylcholine alpha 7 receptor (nAChR α7) subtype have the potential to treat cognitive deficits in patients with Alzheimer’s disease (AD) or schizophrenia. Visuo-spatial paired associates learning (vsPAL) is a task that has been shown to reliably predict conversion from mild cognitive impairment to AD in humans and can also be performed by nonhuman primates. Reversal of scopolamine-induced impairment of vsPAL performance may represent a translational approach for the development of nAChR α7 agonists. The present study investigated the effect of treatment with the acetylcholinesterase inhibitor, donepezil, or three nAChR α7 agonists, BMS-933043, EVP-6124 and RG3487, on vsPAL performance in scopolamine-treated cynomolgus monkeys. Scopolamine administration impaired vsPAL performance accuracy in a dose- and difficulty- dependent manner. The impairment of eventual accuracy, a measure of visuo-spatial learning during the task, was significantly ameliorated by treatment with donepezil (0.3 mg/kg, i.m.), EVP-6124 (0.01 mg/kg, i.m.) or BMS-933043 (0.03, 0.1 and 0.3 mg/kg, i.m.). Both nAChR α7 agonists showed inverted-U shaped dose-effect relationships with EVP-6124 effective at a single dose only whereas BMS-933043 was effective across at least a 10 fold dose/exposure range. RG3487 was not efficacious in this paradigm at the dose range examined (0.03–1 mg/kg, i.m.). These results are the first demonstration that the nAChR α7 agonists, EVP-6124 and BMS-933043, can ameliorate scopolamine-induced cognitive deficits in nonhuman primates performing the vsPAL task. PMID:29261656

  1. Considerations on the calibration of small thermoluminescent dosimeters used for measurement of beta particle absorbed doses in liquid environments.

    PubMed

    Demidecki, A J; Williams, L E; Wong, J Y; Wessels, B W; Yorke, E D; Strandh, M; Strand, S E

    1993-01-01

    An investigation has been carried out on the factors which affect the absolute calibration of thermoluminescent dosimeters (TLDs) used in beta particle absorbed dose evaluations. Four effects on light output (LO) were considered: decay of detector sensitivity with time, finite TLD volume, dose linearity, and energy dependence. Most important of these was the decay of LO with time in culture medium, muscle tissue, and gels. This permanent loss of sensitivity was as large as an order of magnitude over a 21-day interval for the nominally 20-microns-thick disc-shaped CaSO4(Dy) TLDs in gel. Associated leaching of the dosimeter crystals out of the Teflon matrix was observed using scanning electron microscopy. Large channels leading from the outside environment into the TLDs were identified using SEM images. A possibility of batch dependence of fading was indicated. The second most important effect was the apparent reduction of light output due to finite size and increased specific gravity of the dosimeter (volume effect). We estimated this term by calculations as 10% in standard "mini" rods for beta particles from 90Y, but nearly a factor of 3 for 131I beta particles in the same geometry. No significant nonlinearity of the log (light output) with log (absorbed dose) over the range 0.05-20.00 Gy was discovered. Energy dependence of the LO was found to be not detectable, within measurement errors, over the range of 0.60-6.0 MeV mean energy electrons. With careful understanding of these effects, calibration via gel phantom would appear to be an acceptable strategy for mini TLDs used in beta absorbed dose evaluations in media.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Polyethylene glycol 3350 without electrolytes for the treatment of functional constipation in infants and toddlers.

    PubMed

    Loening-Baucke, Vera; Krishna, Rachana; Pashankar, Dinesh S

    2004-11-01

    We have recently reported the safety and efficacy of polyethylene glycol 3350 without electrolytes (PEG) for the daily treatment of constipation in older children. Because there are very few data available on the use of PEG in infants and toddlers, we evaluated the efficacy and safety of PEG for the treatment of constipation in children <2 years of age. This is a retrospective chart review of 75 constipated children <2 years of age at start of PEG therapy. PEG was started at an average dose of 1 g/kg body weight/d and parents were asked to adjust the dose to yield 1 to 2 soft painless stools/d. Data from the history and physical examination were collected initially and at short-term (or=6 months) follow-up. 75 otherwise healthy children received PEG for functional constipation. The mean age was 17 months (range, 1 to 24 months) and the mean duration of constipation was 10 months (range, 0.5 to 23 months). The mean duration of short-term follow-up was 2 months and mean duration of long-term follow-up was 11 months. The mean effective short-term PEG dose was 1.1 g/kg body weight/d and the mean long-term dose was 0.8 g/kg body weight/d. Constipation was relieved in 85% with short-term and in 91% with long-term PEG therapy. Adverse effects were mild and included diarrhea, which disappeared with lowering the dose. No subjects stopped PEG because of adverse effects. PEG is effective, well tolerated and appeared safe for the treatment of functional constipation in children <2 years of age.

  3. Improvements in opti-chromic dosimeters for radiation processing

    NASA Astrophysics Data System (ADS)

    Humpherys, K. C.; Kantz, A. D.

    "Opti-Chromic" dosimeters consisting of radiachromic dye in flourinated polymer tubing have been introduced as a dosimetry system in the range from 10 1 to 5 × 10 4 Gy. Batches of "Opti-Chromic" dosimeters have been produced to evaluate performance under large scale industrial conditions. A systematic study was undertaken to determine the effect of various dosimeter parameters on radiation sensitivity, shelf life, and response characteristics at the higher absorbed doses. These parameters were (A) Type of flourinated polymer tubing; (B) Organic solvent used to activate the radiachromic dye; (C) Concentration of radiachromic dye; (D) Additives to provide proper viscosity, color stability, and high-dose response. Prototype batches were produced and experimental dosimeters exposed to a range of absorbed doses and the response measured as a function of shelf life and dose. The results of the study are presented, and an improved formulation recommended for application to Food Processing. Other formulations may be of value in specific requirements of sensitivity or temperature.

  4. Effects of a chronic lower range of triclosan exposure to a stream mesocosm community

    USGS Publications Warehouse

    Nietch, C.T.; Quinlan, E.L.; Lazorchak, J.; Impellitteri, C.; Raikow, D.; Walters, David M.

    2013-01-01

    Triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol) is an antimicrobial found in consumer soaps and toothpaste. It is in treated wastewater effluents at low part per billion concentrations, representing a potentially chronic exposure condition for biota inhabiting receiving streams. A naturally colonized benthos was created using flow-through indoor mesocosms. Then the benthic communities were dosed to achieve different in-stream triclosan concentrations (Control, 0.1, 0.5, 1.0, 5.0, and 10 µg/L) for 56 days. Water quality parameters and endpoints from bacteria to macroinvertebrates plus interacting abiotic components were measured. Effects of triclosan on specific microbial endpoints were observed at all doses, including an effect on litter decomposition dynamics at doses 1.0 µg/L and higher. Resistance of periphytic bacteria to triclosan significantly increased in doses 0.5 µg/L and above. By the end of dosing, the antimicrobial appeared to stimulate the stream periphyton at the three lowest doses while the two highest doses exhibited decreased stocks of periphyton, including significantly lower bacteria cell densities, and cyanobacteria abundance compared to the control. Beside an effect on benthic ostracods, the changes that occurred in the periphyton did not translate to significant change in the colonizing nematodes, the macroinvertebrate community as a whole, or other measurements of stream function. The results shed light on the role a low, chronic exposure to triclosan may play in effluent dominated streams.

  5. [CYSTEAMINE-INDUCED MODIFICATION OF CYTOGENETIC DAMAGES TO THE CORNEAL EPITHELIUM OF MICE EXPOSED TO CORPUSCULAR RADIATION WITH VARYING LINEAR TRANSFER ENERGIES].

    PubMed

    Vorozhtsova, S V; Bulynina, T M; Molokanov, A G; Ivanov, A A

    2015-01-01

    Cytogenetic damages to cells of the corneal epithelium were studied in mice exposed to protons (10, 25, 50 and 645 MeV), ions of boron, carbon and neon, and X-rays (180 keV) within the dose range from 25 to 750 cGy and injected with a radioprotector. Animals were subjected to a single exposure. The protective effect of β-mercaptoethylamine was tested in the experiment. The radioprotector (0.2 ml) was introduced intraperitoneally 30 minutes before exposure in 350 mI/kg dose. Control animals received the same amount of sodium chloride solution. The animals were sacrificed by cervical dislocation in 24 and 72 hrs. after exposure. It was shown that cysteamine effectively protects in vivo corneal epithelium cells of mice exposed to electromagnetic radiation or protons in a broad energy spectrum (10 to 645 MeV), and to a broad range of radiation doses (25 to 750 cGy), as judged from levels of aberrant mitosis and mitotic activity. The radioprotector exhibited the highest effectiveness in animals exposed to the doses of 50 to 300 cGy. These findings prove that cysteamine may potentially be used for pharmacological protection from protons. The radioprotector failed to prevent chromosomal aberrations after exposure to heavy charged particles of boron, carbon and neon, which implies the need to design radioprotectors against this type of corpuscular radiation specifically.

  6. In vivo dosimetry with radiochromic films in low-voltage intraoperative radiotherapy of the breast.

    PubMed

    Avanzo, M; Rink, A; Dassie, A; Massarut, S; Roncadin, M; Borsatti, E; Capra, E

    2012-05-01

    EBT2 radiochromic films were studied and used for in vivo dosimetry in targeted intraoperative radiotherapy (TARGIT), a technique in which the Intrabeam system (Carl Zeiss, Oberkochen, Germany) is used to perform intraoperative partial breast irradiation with x-rays of 50 kV(p). The energy of the radiation emitted by the Intrabeam with the different spherical applicators, under 1 and 2 cm of solid water, and under the tungsten impregnated rubber used for shielding of the heart in TARGIT of the breast, was characterized with measurements of half-value layer (HVL). The stability of response of EBT2 was verified inside this range of energies. EBT2 films were calibrated using the red and green channels of the absorption spectrum in the 0-20 Gy dose range delivered by the Intrabeam x-rays. The dependence of film response on temperature during irradiation was measured. For in vivo dosimetry, pieces of radiochromic films wrapped in sterile envelopes were inserted after breast conserving surgery and before TARGIT into the excision cavity, on the skin and on the shielded pectoralis fascia for treatments of the left breast. HVLs of the Intrabeam in TARGIT of the breast correspond to effective energies of 20.7-36.3 keV. The response of EBT2 was constant inside this range of energies. We measured the dose to the target tissue and to organs at risk in 23 patients and obtained an average dose of 13.52 ± 1.21 Gy to the target tissue. Dose to the skin in close proximity to the applicator was 2.22 ± 0.97 Gy, 0.29 ± 0.17 Gy at 5-10 cm from the applicator, and 0.08 ± 0.07 Gy at more than 10 cm from the applicator. Dose to the pectoral muscle for left breast treatment was 0.57 ± 0.23 Gy. Our results show that EBT2 films are accurate at the beam energies, dose range, and irradiation temperature found in TARGIT and that in vivo dosimetry in TARGIT with EBT2 films wrapped in sterile envelopes is a feasible procedure. Measured dose to the organs at risk indicates that the technique is safe from side effects to the skin and the heart.

  7. In vivo dosimetry with radiochromic films in low-voltage intraoperative radiotherapy of the breast

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avanzo, M.; Rink, A.; Dassie, A.

    Purpose: EBT2 radiochromic films were studied and used for in vivo dosimetry in targeted intraoperative radiotherapy (TARGIT), a technique in which the Intrabeam system (Carl Zeiss, Oberkochen, Germany) is used to perform intraoperative partial breast irradiation with x-rays of 50 kV{sub p}. Methods: The energy of the radiation emitted by the Intrabeam with the different spherical applicators, under 1 and 2 cm of solid water, and under the tungsten impregnated rubber used for shielding of the heart in TARGIT of the breast, was characterized with measurements of half-value layer (HVL). The stability of response of EBT2 was verified inside thismore » range of energies. EBT2 films were calibrated using the red and green channels of the absorption spectrum in the 0-20 Gy dose range delivered by the Intrabeam x-rays. The dependence of film response on temperature during irradiation was measured. For in vivo dosimetry, pieces of radiochromic films wrapped in sterile envelopes were inserted after breast conserving surgery and before TARGIT into the excision cavity, on the skin and on the shielded pectoralis fascia for treatments of the left breast. Results: HVLs of the Intrabeam in TARGIT of the breast correspond to effective energies of 20.7-36.3 keV. The response of EBT2 was constant inside this range of energies. We measured the dose to the target tissue and to organs at risk in 23 patients and obtained an average dose of 13.52 {+-} 1.21 Gy to the target tissue. Dose to the skin in close proximity to the applicator was 2.22 {+-} 0.97 Gy, 0.29 {+-} 0.17 Gy at 5-10 cm from the applicator, and 0.08 {+-} 0.07 Gy at more than 10 cm from the applicator. Dose to the pectoral muscle for left breast treatment was 0.57 {+-} 0.23 Gy. Conclusions: Our results show that EBT2 films are accurate at the beam energies, dose range, and irradiation temperature found in TARGIT and that in vivo dosimetry in TARGIT with EBT2 films wrapped in sterile envelopes is a feasible procedure. Measured dose to the organs at risk indicates that the technique is safe from side effects to the skin and the heart.« less

  8. Amorphization and recrystallization of epitaxial ReSi2 films grown on Si(100)

    NASA Technical Reports Server (NTRS)

    Kim, Kun HO; Bai, G.; Nicolet, MARC-A.; Mahan, John E.; Geib, Kent M.

    1991-01-01

    The effects of implantation damage and the chemical species of the implant on structural and electrical properties of epitaxial ReSi2 films on Si(100) implanted with Si-28 or Ar-40 ions, at doses ranging from 10 to the 13th/sq cm to 10 to the 15th/sq cm, were investigated using the backscattering spectrometry, XRD, and the van der Pauw techniques. Results showed that ion implantation produces damage in the film, which increases monotonically with dose; the resistivity of the film decreases monotonically with dose.

  9. Phase I study of 6-diazo-5-oxo-L-norleucine (DON).

    PubMed

    Sklaroff, R B; Casper, E S; Magill, G B; Young, C W

    1980-01-01

    We conducted a phase I study of 6-diazo-5-oxo-L-norleucine given iv on a twice weekly schedule. Twenty-six evaluable patients received 31 courses of the drug. Doses ranged from 100 to 500 mg/m2. Nausea with vomiting was the dose-limiting toxic effect, transient thrombocytopenia was seen frequently, and mucositis occurred in 39% of the patients. No definite therapeutic responses were observed in 18 patients with measurable lesions. The recommended dose for phase II studies is 200-300 mg/m2 iv twice weekly.

  10. Uranyl nitrate-exposed rat alveolar macrophages cell death: Influence of superoxide anion and TNF α mediators

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Orona, N.S.; Tasat, D.R., E-mail: deborah.tasat@unsam.edu.ar; School of Dentistry, University of Buenos Aires, M. T. de Alvear 2142

    2012-06-15

    Uranium compounds are widely used in the nuclear fuel cycle, military and many other diverse industrial processes. Health risks associated with uranium exposure include nephrotoxicity, cancer, respiratory, and immune disorders. Macrophages present in body tissues are the main cell type involved in the internalization of uranium particles. To better understand the pathological effects associated with depleted uranium (DU) inhalation, we examined the metabolic activity, phagocytosis, genotoxicity and inflammation on DU-exposed rat alveolar macrophages (12.5–200 μM). Stability and dissolution of DU could differ depending on the dissolvent and in turn alter its biological action. We dissolved DU in sodium bicarbonate (NaHCO{submore » 3} 100 mM) and in what we consider a more physiological vehicle resembling human internal media: sodium chloride (NaCl 0.9%). We demonstrate that uranyl nitrate in NaCl solubilizes, enters the cell, and elicits its cytotoxic effect similarly to when it is diluted in NaHCO{sub 3}. We show that irrespective of the dissolvent employed, uranyl nitrate impairs cell metabolism, and at low doses induces both phagocytosis and generation of superoxide anion (O{sub 2}{sup −}). At high doses it provokes the secretion of TNFα and through all the range of doses tested, apoptosis. We herein suggest that at DU low doses O{sub 2}{sup −} may act as the principal mediator of DNA damage while at higher doses the signaling pathway mediated by O{sub 2}{sup −} may be blocked, prevailing damage to DNA by the TNFα route. The study of macrophage functions after uranyl nitrate treatment could provide insights into the pathophysiology of uranium‐related diseases. -- Highlights: ► Uranyl nitrate effect on cultured macrophages is linked to the doses and independent of its solubility. ► At low doses uranyl nitrate induces generation of superoxide anion. ► At high doses uranyl nitrate provokes secretion of TNFα. ► Uranyl nitrate induces apoptosis through all the range of doses tested.« less

  11. Levofloxacin Population Pharmacokinetics in South African Children Treated for Multidrug-Resistant Tuberculosis.

    PubMed

    Denti, Paolo; Garcia-Prats, Anthony J; Draper, Heather R; Wiesner, Lubbe; Winckler, Jana; Thee, Stephanie; Dooley, Kelly E; Savic, Rada M; McIlleron, Helen M; Schaaf, H Simon; Hesseling, Anneke C

    2018-02-01

    Levofloxacin is increasingly used in the treatment of multidrug-resistant tuberculosis (MDR-TB). There are limited pediatric pharmacokinetic data to inform dose selection for children. Children routinely receiving levofloxacin (250-mg adult tablets) for MDR-TB prophylaxis or disease in Cape Town, South Africa, underwent pharmacokinetic sampling following receipt of a dose of 15 or 20 mg/kg of body weight given as a whole or crushed tablet(s) orally or via a nasogastric tube. Pharmacokinetic parameters were estimated using nonlinear mixed-effects modeling. Model-based simulations were performed to estimate the doses across weight bands that would achieve adult exposures with 750-mg once-daily dosing. One hundred nine children were included. The median age was 2.1 years (range, 0.3 to 8.7 years), and the median weight was 12 kg (range, 6 to 22 kg). Levofloxacin followed 2-compartment kinetics with first-order elimination and absorption with a lag time. After inclusion of allometric scaling, the model characterized the age-driven maturation of clearance (CL), with the effect reaching 50% of that at maturity at about 2 months after birth and 100% of that at maturity by 2 years of age. CL in a typical child (weight, 12 kg; age, 2 years) was 4.7 liters/h. HIV infection reduced CL by 16%. By use of the adult 250-mg formulation, levofloxacin exposures were substantially lower than those reported in adults receiving a similar dose on a milligram-per-kilogram basis. To achieve adult-equivalent exposures at a 750-mg daily dose, higher levofloxacin pediatric doses of from 18 mg/kg/day for younger children with weights of 3 to 4 kg (due to immature clearance) to 40 mg/kg/day for older children may be required. The doses of levofloxacin currently recommended for the treatment of MDR-TB in children result in exposures considerably lower than those in adults. The effects of different formulations and formulation manipulation require further investigation. We recommend age- and weight-banded doses of 250-mg tablets of the adult formulation most likely to achieve target concentrations for prospective evaluation. Copyright © 2018 American Society for Microbiology.

  12. Low-Dose Radiotherapy in Indolent Lymphoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossier, Christine; Schick, Ulrike; Miralbell, Raymond

    Purpose: To assess the response rate, duration of response, and overall survival after low-dose involved-field radiotherapy in patients with recurrent low-grade lymphoma or chronic lymphocytic leukemia (CLL). Methods and Materials: Forty-three (24 women, 19 men) consecutive patients with indolent lymphoma or CLL were treated with a total dose of 4 Gy (2 x 2 Gy) using 6- 18-MV photons. The median age was 73 years (range, 39-88). Radiotherapy was given either after (n = 32; 75%) or before (n = 11; 25%) chemotherapy. The median time from diagnosis was 48 months (range, 1-249). The median follow-up period was 20 monthsmore » (range, 1-56). Results: The overall response rate was 90%. Twelve patients (28%) had a complete response, 15 (35%) had a partial response, 11 (26%) had stable disease, and 5 (11%) had progressive disease. The median overall survival for patients with a positive response (complete response/partial response/stable disease) was 41 months; for patients with progressive disease it was 6 months (p = 0.001). The median time to in-field progression was 21 months (range, 0-24), and the median time to out-field progression was 8 months (range, 0-40). The 3-year in-field control was 92% in patients with complete response (median was not reached). The median time to in-field progression was 9 months (range, 0.5-24) in patients with partial response and 6 months (range, 0.6-6) in those with stable disease (p < 0.05). Younger age, positive response to radiotherapy, and no previous chemotherapy were the best factors influencing the outcome. Conclusions: Low-dose involved-field radiotherapy is an effective treatment in the management of patients with recurrent low-grade lymphoma or CLL.« less

  13. Effective atomic numbers and electron densities of bioactive glasses for photon interaction

    NASA Astrophysics Data System (ADS)

    Shantappa, Anil; Hanagodimath, S. M.

    2015-08-01

    This work was carried out to study the nature of mass attenuation coefficient of bioactive glasses for gamma rays. Bioactive glasses are a group of synthetic silica-based bioactive materials with unique bone bonding properties. In the present study, we have calculated the effective atomic number, electron density for photon interaction of some selected bioactive glasses viz., SiO2-Na2O, SiO2-Na2O-CaO and SiO2-Na2O-P2O5 in the energy range 1 keV to 100 MeV. We have also computed the single valued effective atomic number by using XMuDat program. It is observed that variation in effective atomic number (ZPI, eff) depends also upon the weight fractions of selected bioactive glasses and range of atomic numbers of the elements. The results shown here on effective atomic number, electron density will be more useful in the medical dosimetry for the calculation of absorbed dose and dose rate.

  14. Effect of chronic kidney disease on warfarin management in a pharmacist-managed anticoagulation clinic.

    PubMed

    Kleinow, Megan E; Garwood, Candice L; Clemente, Jennifer L; Whittaker, Peter

    2011-09-01

    There is growing evidence that kidney disease affects hepatically cleared drugs. Accordingly, we hypothesized that chronic kidney disease (CKD) would disrupt anticoagulation of warfarin-treated patients and thereby increase the amount of management required to maintain appropriate anticoagulation. Specifically, we anticipated that more dose manipulations (both dose changes and transient dose adjustments) and shorter times between scheduled clinic visits would be required for anticoagulation patients with CKD. To determine how CKD affected warfarin maintenance dose, anticoagulation stability, the proportion of clinic visits that necessitated a dose manipulation (either a change in the prescribed weekly dose or a transient dose adjustment), and the length of time between scheduled visits in 2 pharmacist-managed anticoagulation clinics. Our retrospective, cohort chart review investigated warfarin response in anticoagulation clinic patients. From the clinic database of patients with an international normalized ratio (INR) target range of 2.0-3.0, we matched 20 of 24 patients with CKD (estimated creatinine clearance less than 60 mL per minute) to 20 comparison group patients (estimated creatinine clearance greater than 60 mL per minute) based on parameters demonstrated to affect warfarin dose: ethnicity, gender, age, body surface area, and simvastatin use. We calculated the average weekly dose used to maintain target INR (assessment period range=116-1,408 days). To evaluate anticoagulation stability and patient management, we quantified several parameters, including the percentage of total time in therapeutic range, the proportion of clinic visits that required a dose change, and the time between scheduled visits. We compared group means using t-tests, and categorical data were compared using Fisher's exact test. Our population was predominantly female (75%) and of African ancestry (95%); average age 60 years. Patients with CKD required a 24% lower dose than the comparison group (mean [SD]=35.9 [10.7] vs. 47.0 [11.2] mg per week, P=0.003) and spent less time in therapeutic range required increased clinic management versus the comparison group, as indicated by a significantly higher proportion of clinic visits at which dose changes occurred (22% vs. 12%, P<0.001) and a decreased time between scheduled visits (mean [SD] of 16.0 [3.2] days vs. 19.7 [3.4] days, respectively, P=0.001). CKD was associated with both decreased warfarin maintenance dose and decreased anticoagulation stability which, in turn, required more frequent and intensive anticoagulation clinic management.

  15. Particle effects on ultraviolet disinfection of coliform bacteria in recycled water.

    PubMed

    Jolis, D; Lam, C; Pitt, P

    2001-01-01

    Pilot- and bench-scale coliform inactivation tests with UV irradiation were used to show how suspended solids remaining in filtered secondary effluent affect the efficiency of the UV disinfection process. Observed kinetic inactivation rates decreased with increasing suspended particle sizes of 7 microm or larger present in tertiary effluent. First-order inactivation rates estimated from collimated beam dose-response curves for discrete ranges of UV doses were substantially different, which should caution researchers not to compare inactivation data obtained with largely dissimilar UV doses or suspended particle distributions. A dose of approximately 800 J/m2 was identified as the minimum dose that will consistently meet the California wastewater reclamation coliform criterion when applied to in-line filtration effluent.

  16. Dose and dose rate extrapolation factors for malignant and non-malignant health endpoints after exposure to gamma and neutron radiation.

    PubMed

    Tran, Van; Little, Mark P

    2017-11-01

    Murine experiments were conducted at the JANUS reactor in Argonne National Laboratory from 1970 to 1992 to study the effect of acute and protracted radiation dose from gamma rays and fission neutron whole body exposure. The present study reports the reanalysis of the JANUS data on 36,718 mice, of which 16,973 mice were irradiated with neutrons, 13,638 were irradiated with gamma rays, and 6107 were controls. Mice were mostly Mus musculus, but one experiment used Peromyscus leucopus. For both types of radiation exposure, a Cox proportional hazards model was used, using age as timescale, and stratifying on sex and experiment. The optimal model was one with linear and quadratic terms in cumulative lagged dose, with adjustments to both linear and quadratic dose terms for low-dose rate irradiation (<5 mGy/h) and with adjustments to the dose for age at exposure and sex. After gamma ray exposure there is significant non-linearity (generally with upward curvature) for all tumours, lymphoreticular, respiratory, connective tissue and gastrointestinal tumours, also for all non-tumour, other non-tumour, non-malignant pulmonary and non-malignant renal diseases (p < 0.001). Associated with this the low-dose extrapolation factor, measuring the overestimation in low-dose risk resulting from linear extrapolation is significantly elevated for lymphoreticular tumours 1.16 (95% CI 1.06, 1.31), elevated also for a number of non-malignant endpoints, specifically all non-tumour diseases, 1.63 (95% CI 1.43, 2.00), non-malignant pulmonary disease, 1.70 (95% CI 1.17, 2.76) and other non-tumour diseases, 1.47 (95% CI 1.29, 1.82). However, for a rather larger group of malignant endpoints the low-dose extrapolation factor is significantly less than 1 (implying downward curvature), with central estimates generally ranging from 0.2 to 0.8, in particular for tumours of the respiratory system, vasculature, ovary, kidney/urinary bladder and testis. For neutron exposure most endpoints, malignant and non-malignant, show downward curvature in the dose response, and for most endpoints this is statistically significant (p < 0.05). Associated with this, the low-dose extrapolation factor associated with neutron exposure is generally statistically significantly less than 1 for most malignant and non-malignant endpoints, with central estimates mostly in the range 0.1-0.9. In contrast to the situation at higher dose rates, there are statistically non-significant decreases of risk per unit dose at gamma dose rates of less than or equal to 5 mGy/h for most malignant endpoints, and generally non-significant increases in risk per unit dose at gamma dose rates ≤5 mGy/h for most non-malignant endpoints. Associated with this, the dose-rate extrapolation factor, the ratio of high dose-rate to low dose-rate (≤5 mGy/h) gamma dose response slopes, for many tumour sites is in the range 1.2-2.3, albeit not statistically significantly elevated from 1, while for most non-malignant endpoints the gamma dose-rate extrapolation factor is less than 1, with most estimates in the range 0.2-0.8. After neutron exposure there are non-significant indications of lower risk per unit dose at dose rates ≤5 mGy/h compared to higher dose rates for most malignant endpoints, and for all tumours (p = 0.001), and respiratory tumours (p = 0.007) this reduction is conventionally statistically significant; for most non-malignant outcomes risks per unit dose non-significantly increase at lower dose rates. Associated with this, the neutron dose-rate extrapolation factor is less than 1 for most malignant and non-malignant endpoints, in many cases statistically significantly so, with central estimates mostly in the range 0.0-0.2.

  17. Exposure of the Heart in Breast Cancer Radiation Therapy: A Systematic Review of Heart Doses Published During 2003 to 2013

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, Carolyn W., E-mail: carolyn.taylor@ctsu.ox.ac.uk; Wang, Zhe; Macaulay, Elizabeth

    Purpose: Breast cancer radiation therapy cures many women, but where the heart is exposed, it can cause heart disease. We report a systematic review of heart doses from breast cancer radiation therapy that were published during 2003 to 2013. Methods and Materials: Eligible studies were those reporting whole-heart dose (ie, dose averaged over the whole heart). Analyses considered the arithmetic mean of the whole-heart doses for the CT plans for each regimen in each study. We termed this “mean heart dose.” Results: In left-sided breast cancer, mean heart dose averaged over all 398 regimens reported in 149 studies from 28more » countries was 5.4 Gy (range, <0.1-28.6 Gy). In regimens that did not include the internal mammary chain (IMC), average mean heart dose was 4.2 Gy and varied with the target tissues irradiated. The lowest average mean heart doses were from tangential radiation therapy with either breathing control (1.3 Gy; range, 0.4-2.5 Gy) or treatment in the lateral decubitus position (1.2 Gy; range, 0.8-1.7 Gy), or from proton radiation therapy (0.5 Gy; range, 0.1-0.8 Gy). For intensity modulated radiation therapy mean heart dose was 5.6 Gy (range, <0.1-23.0 Gy). Where the IMC was irradiated, average mean heart dose was around 8 Gy and varied little according to which other targets were irradiated. Proton radiation therapy delivered the lowest average mean heart dose (2.6 Gy, range, 1.0-6.0 Gy), and tangential radiation therapy with a separate IMC field the highest (9.2 Gy, range, 1.9-21.0 Gy). In right-sided breast cancer, the average mean heart dose was 3.3 Gy based on 45 regimens in 23 studies. Conclusions: Recent estimates of typical heart doses from left breast cancer radiation therapy vary widely between studies, even for apparently similar regimens. Maneuvers to reduce heart dose in left tangential radiation therapy were successful. Proton radiation therapy delivered the lowest doses. Inclusion of the IMC doubled typical heart dose.« less

  18. Dose-response-a challenge for allelopathy?

    PubMed

    Belz, Regina G; Hurle, Karl; Duke, Stephen O

    2005-04-01

    The response of an organism to a chemical depends, among other things, on the dose. Nonlinear dose-response relationships occur across a broad range of research fields, and are a well established tool to describe the basic mechanisms of phytotoxicity. The responses of plants to allelochemicals as biosynthesized phytotoxins, relate as well to nonlinearity and, thus, allelopathic effects can be adequately quantified by nonlinear mathematical modeling. The current paper applies the concept of nonlinearity to assorted aspects of allelopathy within several bioassays and reveals their analysis by nonlinear regression models. Procedures for a valid comparison of effective doses between different allelopathic interactions are presented for both, inhibitory and stimulatory effects. The dose-response applications measure and compare the responses produced by pure allelochemicals [scopoletin (7-hydroxy-6-methoxy-2H-1-benzopyran-2-one); DIBOA (2,4-dihydroxy-2H-1,4-benzoxaxin-3(4H)-one); BOA (benzoxazolin-2(3H)-one); MBOA (6-methoxy-benzoxazolin-2(3H)-one)], involved in allelopathy of grain crops, to demonstrate how some general principles of dose responses also relate to allelopathy. Hereupon, dose-response applications with living donor plants demonstrate the validity of these principles for density-dependent phytotoxicity of allelochemicals produced and released by living plants (Avena sativa L., Secale cereale L., Triticum L. spp.), and reveal the use of such experiments for initial considerations about basic principles of allelopathy. Results confirm that nonlinearity applies to allelopathy, and the study of allelopathic effects in dose-response experiments allows for new and challenging insights into allelopathic interactions.

  19. Effect of gamma irradiation on rice and its food products

    NASA Astrophysics Data System (ADS)

    Sung, Wen-Chieh

    2005-07-01

    Two milled indica rice varieties were exposed to gamma radiation with doses ranging from 0 to 1.0 kGy. The effects of gamma irradiation on rice flour pasting properties and the qualities of its food product, rice curd, were compared to the effects of storage. A dose of 1 kGy can decrease the flour paste viscosity and tenderize the texture of the rice curd to similar levels as those obtained after 12 months of storage. It was thus shown that gamma irradiation could shorten the indica rice aging time and improve the processing stability and quality of rice products.

  20. Protection of intestinal damage by pretreatment with cytarabine (cytosine arabinoside)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phelps, T.A.; Blackett, N.M.

    The circumstances in which cytarabine (cytosine arabinoside) ''protects'' intestinal epithelial stem cells against radiation have been investigated. Special attention has been given to this protective effect with radiation doses in the clinically used range in order to determine whether the protective effect might be of use in radiotherapy. It has been shown that 12 hours after cytarabine the D/sub 0/ and extrapolation number are increased when large single doses of radiation are used. To determine the effect of cytarabine at lower doses, it is necessary to use a second irradiation as an ''assay'' dose. By this means it is shownmore » that there is more protection than can be accounted for by the change in D/sub 0/ and extrapolation number at the time of the first dose. Evidence is presented indicating that the rate of stem cell regeneration is not increased by cytarabine pretreatment. Finally, the relation between intestinal protection, bone marrow stem cell enhanced recovery and improved animal survival as a result of cytarabine pretreatment is discussed.« less

Top