Sample records for effective monitoring system

  1. Potential of plant genetic systems for monitoring and screening mutagens

    PubMed Central

    Nilan, R. A.

    1978-01-01

    Plants have too long been ignored as useful screening and monitoring systems of environmental mutagens. However, there are about a dozen reliable, some even unique, plant genetic systems that can increase the scope and effectiveness of chemical and physical mutagen screening and monitoring procedures. Some of these should be included in the Tier II tests. Moreover, plants are the only systems now in use as monitors of genetic effects caused by polluted atmosphere and water and by pesticides. There are several major advantages of the plant test systems which relate to their reproductive nature, easy culture and growth habits that should be considered in mutagen screening and monitoring. In addition to these advantages, the major plant test systems exhibit numerous genetic and chromosome changes for determining the effects of mutagens. Some of these have not yet been detected in other nonmammalian and mammalian test systems, but probably occur in the human organism. Plants have played major roles in various aspects of mutagenesis research, primarily in mutagen screening (detection and verification of mutagenic activity), mutagen monitoring, and determining mutagen effects and mechanisms of mutagen action. They have played lesser roles in quantification of mutagenic activity and understanding the nature of induced mutations. Mutagen monitoring with plants, especially in situ on land or in water, will help determine potential genetic hazards of air and water pollutants and protect the genetic purity of crop plants and the purity of the food supply. The Tradescantia stamen-hair system is used in a mobile laboratory for determining the genetic effects of industrial and automobile pollution in a number of sites in the U.S.A. The fern is employed for monitoring genetic effects of water pollution in the Eastern states. The maize pollen system and certain weeds have monitored genetic effects of pesticides. Several other systems that have considerable value and should be developed and more widely used in mutagen monitoring and screening, especially for in situ monitoring, are discussed. Emphasis is placed on pollen systems in which changes in pollen structure, chemistry, and chromosomes can be scored for monitoring; and screening systems which can record low levels of genetic effects as well as provide information on the nature of induced mutations. The value of plant systems for monitoring and screening mutagens can be improved by: greater knowledge of plant cell processes at the molecular and ultrastructural levels; relating these processes to mutagen effects and plant cell responses; improving current systems for increased sensitivity, ease of detecting genetic and chromosome changes, recording of data (including automation), and for extending the range of genetic and chromosome end points; and designing and developing new systems with the aid of previous and current botanical and genetic knowledge. PMID:367768

  2. Application research of Ganglia in Hadoop monitoring and management

    NASA Astrophysics Data System (ADS)

    Li, Gang; Ding, Jing; Zhou, Lixia; Yang, Yi; Liu, Lei; Wang, Xiaolei

    2017-03-01

    There are many applications of Hadoop System in the field of large data, cloud computing. The test bench of storage and application in seismic network at Earthquake Administration of Tianjin use with Hadoop system, which is used the open source software of Ganglia to operate and monitor. This paper reviews the function, installation and configuration process, application effect of operating and monitoring in Hadoop system of the Ganglia system. It briefly introduces the idea and effect of Nagios software monitoring Hadoop system. It is valuable for the industry in the monitoring system of cloud computing platform.

  3. Matrix Failure Modes and Effects Analysis as a Knowledge Base for a Real Time Automated Diagnosis Expert System

    NASA Technical Reports Server (NTRS)

    Herrin, Stephanie; Iverson, David; Spukovska, Lilly; Souza, Kenneth A. (Technical Monitor)

    1994-01-01

    Failure Modes and Effects Analysis contain a wealth of information that can be used to create the knowledge base required for building automated diagnostic Expert systems. A real time monitoring and diagnosis expert system based on an actual NASA project's matrix failure modes and effects analysis was developed. This Expert system Was developed at NASA Ames Research Center. This system was first used as a case study to monitor the Research Animal Holding Facility (RAHF), a Space Shuttle payload that is used to house and monitor animals in orbit so the effects of space flight and microgravity can be studied. The techniques developed for the RAHF monitoring and diagnosis Expert system are general enough to be used for monitoring and diagnosis of a variety of other systems that undergo a Matrix FMEA. This automated diagnosis system was successfully used on-line and validated on the Space Shuttle flight STS-58, mission SLS-2 in October 1993.

  4. Effects of blind spot monitoring systems on police-reported lane-change crashes.

    PubMed

    Cicchino, Jessica B

    2018-06-21

    To examine the effectiveness of blind spot monitoring systems in preventing police-reported lane-change crashes. Poisson regression was used to compare crash involvement rates per insured vehicle year in police-reported lane-change crashes in 26 U.S. states during 2009-2015 between vehicles with blind spot monitoring and the same vehicle models without the optional system, controlling for other factors that can affect crash risk. Crash involvement rates in lane-change crashes were 14% lower (95% confidence limits -24% to -2%) among vehicles with blind spot monitoring than those without. Blind spot monitoring systems are effective in preventing police-reported lane-change crashes when considering crashes of all severities. If every U.S. vehicle in 2015 were equipped with blind spot monitoring that performed like the study systems, it is estimated that about 50,000 crashes could have been prevented.

  5. Definition, Capabilities, and Components of a Terrestrial Carbon Monitoring System

    NASA Technical Reports Server (NTRS)

    West, Tristram O.; Brown, Molly E.; Duren, Riley M.; Ogle, Stephen M.; Moss, Richard H.

    2013-01-01

    Research efforts for effectively and consistently monitoring terrestrial carbon are increasing in number. As such, there is a need to define carbon monitoring and how it relates to carbon cycle science and carbon management. There is also a need to identify capabilities of a carbon monitoring system and the system components needed to develop the capabilities. Capabilities that enable the effective application of a carbon monitoring system for monitoring and management purposes may include: reconciling carbon stocks and fluxes, developing consistency across spatial and temporal scales, tracking horizontal movement of carbon, attribution of emissions to originating sources, cross-sectoral accounting, uncertainty quantification, redundancy and policy relevance. Focused research is needed to integrate these capabilities for sustained estimates of carbon stocks and fluxes. Additionally, if monitoring is intended to inform management decisions, management priorities should be considered prior to development of a monitoring system.

  6. Is There a Lexical Bias Effect in Comprehension Monitoring?

    ERIC Educational Resources Information Center

    Severens, Els; Hartsuiker, Robert J.

    2009-01-01

    Event-related potentials were used to investigate if there is a lexical bias effect in comprehension monitoring. The lexical bias effect in language production (the tendency of phonological errors to result in existing words rather than nonwords) has been attributed to an internal self-monitoring system, which uses the comprehension system, and…

  7. Coma Patient Monitoring System Using Image Processing

    NASA Astrophysics Data System (ADS)

    Sankalp, Meenu

    2011-12-01

    COMA PATIENT MONITORING SYSTEM provides high quality healthcare services in the near future. To provide more convenient and comprehensive medical monitoring in big hospitals since it is tough job for medical personnel to monitor each patient for 24 hours.. The latest development in patient monitoring system can be used in Intensive Care Unit (ICU), Critical Care Unit (CCU), and Emergency Rooms of hospital. During treatment, the patient monitor is continuously monitoring the coma patient to transmit the important information. Also in the emergency cases, doctor are able to monitor patient condition efficiently to reduce time consumption, thus it provides more effective healthcare system. So due to importance of patient monitoring system, the continuous monitoring of the coma patient can be simplified. This paper investigates about the effects seen in the patient using "Coma Patient Monitoring System" which is a very advanced product related to physical changes in body movement of the patient and gives Warning in form of alarm and display on the LCD in less than one second time. It also passes a sms to a person sitting at the distant place if there exists any movement in any body part of the patient. The model for the system uses Keil software for the software implementation of the developed system.

  8. A Study about the 3S-based Great Ruins Monitoring and Early-warning System

    NASA Astrophysics Data System (ADS)

    Xuefeng, W.; Zhongyuan, H.; Gongli, L.; Li, Z.

    2015-08-01

    Large-scale urbanization construction and new countryside construction, frequent natural disasters, and natural corrosion pose severe threat to the great ruins. It is not uncommon that the cultural relics are damaged and great ruins are occupied. Now the ruins monitoring mainly adopt general monitoring data processing system which can not effectively exert management, display, excavation analysis and data sharing of the relics monitoring data. Meanwhile those general software systems require layout of large number of devices or apparatuses, but they are applied to small-scope relics monitoring only. Therefore, this paper proposes a method to make use of the stereoscopic cartographic satellite technology to improve and supplement the great ruins monitoring index system and combine GIS and GPS to establish a highly automatic, real-time and intelligent great ruins monitoring and early-warning system in order to realize collection, processing, updating, spatial visualization, analysis, distribution and sharing of the monitoring data, and provide scientific and effective data for the relics protection, scientific planning, reasonable development and sustainable utilization.

  9. Evaluating the Effect of Integrated System Health Management on Mission Effectiveness

    DTIC Science & Technology

    2013-03-01

    Health Status, Fault Detection , IMS Commands «Needline» 110 B.6 OV-5a « O V -5 » a c t O V -5 [ O V -5 a...UAS to self- detect , isolate, and diagnose system health problems. Current flight avionics architectures may include lower level sub-system health ... monitoring or may isolate health monitoring functions to a black box configuration, but a vehicle-wide health monitoring information system has

  10. Monitoring is not enough: on the need for a model-based approach to migratory bird management

    USGS Publications Warehouse

    Nichols, J.D.; Bonney, Rick; Pashley, David N.; Cooper, Robert; Niles, Larry

    2000-01-01

    Informed management requires information about system state and about effects of potential management actions on system state. Population monitoring can provide the needed information about system state, as well as information that can be used to investigate effects of management actions. Three methods for investigating effects of management on bird populations are (1) retrospective analysis, (2) formal experimentation and constrained-design studies, and (3) adaptive management. Retrospective analyses provide weak inferences, regardless of the quality of the monitoring data. The active use of monitoring data in experimental or constrained-design studies or in adaptive management is recommended. Under both approaches, learning occurs via the comparison of estimates from the monitoring program with predictions from competing management models.

  11. A remote condition monitoring system for wind-turbine based DG systems

    NASA Astrophysics Data System (ADS)

    Ma, X.; Wang, G.; Cross, P.; Zhang, X.

    2012-05-01

    In this paper, a remote condition monitoring system is proposed, which fundamentally consists of real-time monitoring modules on the plant side, a remote support centre and the communications between them. The paper addresses some of the key issues related on the monitoring system, including i) the implementation and configuration of a VPN connection, ii) an effective database system to be able to handle huge amount of monitoring data, and iii) efficient data mining techniques to convert raw data into useful information for plant assessment. The preliminary results have demonstrated that the proposed system is practically feasible and can be deployed to monitor the emerging new energy generation systems.

  12. Development of living body information monitoring system

    NASA Astrophysics Data System (ADS)

    Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko

    2010-03-01

    The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.

  13. Development of living body information monitoring system

    NASA Astrophysics Data System (ADS)

    Sakamoto, Hidetoshi; Ohbuchi, Yoshifumi; Torigoe, Ippei; Miyagawa, Hidekazu; Murayama, Nobuki; Hayashida, Yuki; Igasaki, Tomohiko

    2009-12-01

    The easy monitoring systems of contact and non-contact living body information for preventing the the Sudden Infant Death Syndrome (SIDS) were proposed as an alternative monitoring system of the infant's vital information. As for the contact monitoring system, respiration sensor, ECG electrodes, thermistor and IC signal processor were integrated into babies' nappy holder. This contact-monitoring unit has RF transmission function and the obtained data are analyzed in real time by PC. In non-contact mortaring system, the infrared thermo camera was used. The surrounding of the infant's mouth and nose is monitored and the respiration rate is obtained by thermal image processing of its temperature change image of expired air. This proposed system of in-sleep infant's vital information monitoring system and unit are very effective as not only infant's condition monitoring but also nursing person's one.

  14. Environmental-Socio-Economic Monitoring as a Tool of Region’s Environmental-Economic System Management

    NASA Astrophysics Data System (ADS)

    Galanina, T. V.; Baumgarten, M. I.; Mikhailov, V. G.; Koroleva, T. G.; Mikhailov, G. S.

    2017-01-01

    The paper deals with the region’s environmental-economic system management through a tool such as the environmental-socio-economic monitoring. The purpose of research - is analysis and development of theoretical assumptions of environmental-socio-economic monitoring system for the effective management of geographically distributed environmental-economic system. The main elements of environmental-socio-economic monitoring are identified, taking into account the characteristics of the studied area. The main result of the research is the development of multi-functional integrated monitoring system for the evaluation of the indicators "gross domestic product" and "gross national product", taking into account the influence of environmental factors. The results of the study conducted may be recommended to the regional and federal governments to support the effective, environment-friendly management decision-making consistent with the overall development concept.

  15. Human region segmentation and description methods for domiciliary healthcare monitoring using chromatic methodology

    NASA Astrophysics Data System (ADS)

    Al-Temeemy, Ali A.

    2018-03-01

    A descriptor is proposed for use in domiciliary healthcare monitoring systems. The descriptor is produced from chromatic methodology to extract robust features from the monitoring system's images. It has superior discrimination capabilities, is robust to events that normally disturb monitoring systems, and requires less computational time and storage space to achieve recognition. A method of human region segmentation is also used with this descriptor. The performance of the proposed descriptor was evaluated using experimental data sets, obtained through a series of experiments performed in the Centre for Intelligent Monitoring Systems, University of Liverpool. The evaluation results show high recognition performance for the proposed descriptor in comparison to traditional descriptors, such as moments invariant. The results also show the effectiveness of the proposed segmentation method regarding distortion effects associated with domiciliary healthcare systems.

  16. Automated and electronically assisted hand hygiene monitoring systems: a systematic review.

    PubMed

    Ward, Melissa A; Schweizer, Marin L; Polgreen, Philip M; Gupta, Kalpana; Reisinger, Heather S; Perencevich, Eli N

    2014-05-01

    Hand hygiene is one of the most effective ways to prevent transmission of health care-associated infections. Electronic systems and tools are being developed to enhance hand hygiene compliance monitoring. Our systematic review assesses the existing evidence surrounding the adoption and accuracy of automated systems or electronically enhanced direct observations and also reviews the effectiveness of such systems in health care settings. We systematically reviewed PubMed for articles published between January 1, 2000, and March 31, 2013, containing the terms hand AND hygiene or hand AND disinfection or handwashing. Resulting articles were reviewed to determine if an electronic system was used. We identified 42 articles for inclusion. Four types of systems were identified: electronically assisted/enhanced direct observation, video-monitored direct observation systems, electronic dispenser counters, and automated hand hygiene monitoring networks. Fewer than 20% of articles identified included calculations for efficiency or accuracy. Limited data are currently available to recommend adoption of specific automatic or electronically assisted hand hygiene surveillance systems. Future studies should be undertaken that assess the accuracy, effectiveness, and cost-effectiveness of such systems. Given the restricted clinical and infection prevention budgets of most facilities, cost-effectiveness analysis of specific systems will be required before these systems are widely adopted. Published by Mosby, Inc.

  17. On predicting monitoring system effectiveness

    NASA Astrophysics Data System (ADS)

    Cappello, Carlo; Sigurdardottir, Dorotea; Glisic, Branko; Zonta, Daniele; Pozzi, Matteo

    2015-03-01

    While the objective of structural design is to achieve stability with an appropriate level of reliability, the design of systems for structural health monitoring is performed to identify a configuration that enables acquisition of data with an appropriate level of accuracy in order to understand the performance of a structure or its condition state. However, a rational standardized approach for monitoring system design is not fully available. Hence, when engineers design a monitoring system, their approach is often heuristic with performance evaluation based on experience, rather than on quantitative analysis. In this contribution, we propose a probabilistic model for the estimation of monitoring system effectiveness based on information available in prior condition, i.e. before acquiring empirical data. The presented model is developed considering the analogy between structural design and monitoring system design. We assume that the effectiveness can be evaluated based on the prediction of the posterior variance or covariance matrix of the state parameters, which we assume to be defined in a continuous space. Since the empirical measurements are not available in prior condition, the estimation of the posterior variance or covariance matrix is performed considering the measurements as a stochastic variable. Moreover, the model takes into account the effects of nuisance parameters, which are stochastic parameters that affect the observations but cannot be estimated using monitoring data. Finally, we present an application of the proposed model to a real structure. The results show how the model enables engineers to predict whether a sensor configuration satisfies the required performance.

  18. Remote Monitoring of Near-Surface Soil Moisture Dynamics In Unstable Slopes Using a Low-Power Autonomous Resistivity Imaging System

    NASA Astrophysics Data System (ADS)

    Chambers, J. E.; Meldrum, P.; Gunn, D.; Wilkinson, P. B.; Uhlemann, S.; Swift, R. T.; Kuras, O.; Inauen, C.; Hutchinson, D.; Butler, S.

    2016-12-01

    ERT monitoring has been demonstrated in numerous studies as an effective means of imaging near surface processes for applications as diverse as permafrost studies and contaminated land assessment. A limiting factor in applying time-lapse ERT for long-term studies in remote locations has been the availability of cost-effective ERT measurement systems designed specifically for monitoring applications. Typically, monitoring is undertaken using repeated manual data collection, or by building conventional survey instruments into a monitoring setup. The latter often requires high power and is therefore difficult to operate remotely without access to mains electricity. We describe the development of a low-power resistivity imaging system designed specifically for remote monitoring, taking advantage of, e.g., solar power and data telemetry. Here, we present the results of two field deployments. The system has been installed on an active railway cutting to provide insights into the effect of vegetation on the moisture dynamics in unstable infrastructure slopes and to gather subsurface information for pro-active remediation measures. The system, comprising 255 electrodes, acquires 4596 reciprocal measurement pairs twice daily during standard operation. In case of severe weather events, the measurement schedule is reactively changed, to gather high temporal resolution data to image rainfall infiltration processes. The system has also been installed along a leaking and marginally stable canal embankment; a less favourable location for remote monitoring, with limited solar power and poor mobile reception. Nevertheless, the acquired data indicated the effectiveness of remedial actions on the canal. The ERT results showed that one leak was caused by the canal and fixed during remediation, while two other "leaks" were shown to be effects of groundwater dynamics. The availability of cost-effective, low-power ERT monitoring instrumentation, combined with an automated workflow of data processing and visualisation, has the potential to contribute to a step-change in the management and early warning of slope instability.

  19. Department of Defense Chemical and Biological Defense Program. FY2004-2006 Performance Plan

    DTIC Science & Technology

    2005-03-01

    Agents (NTAs) Compare the direct effects of PAF on smooth muscle, hematic constituents, and lung to determine role in toxicity. Continue to identify...Range Biometric Target ID System Explore technologies for a long range biometric target identification system. Air Containment Monitoring System...Continue development of systems for contained air monitoring for chemical agents.Long Range Biometric Air Containment Monitoring System Continued

  20. Effects of a mobility monitoring system on the cost of care in relation to reimbursement at Swiss nursing homes: learnings from a randomized controlled trial.

    PubMed

    Stark, Mario; Tietz, Rigo; Gattinger, Heidrun; Hantikainen, Virpi; Ott, Stefan

    2017-12-01

    Nursing homes in Switzerland are under pressure to efficiently coordinate staff activities to cover their personnel costs under the care financing system. In this study, the use of a mobility monitoring system accompanied with case conferences was investigated in order to improve sleep quality and estimate the cost benefit of this intervention. In an open two-phase randomized controlled trial at three nursing homes, residents with cognitive impairment were randomly assigned to an intervention group and a control group. In the intervention group, a 10-week period of intensive use of the monitoring system and case conferences led by an advanced nurse practitioner (Phase I) was followed by 3 months of reduced use of the monitoring system and case conferences led by an internal registered nurse (Phase II). In the control group, the monitoring system was only used for data acquisition. Nurses reported the activities with a specifically developed tool. Based on the recorded activities, the cost of care was calculated. The correlating reimbursement per patient was calculated from the care levels in the Swiss reimbursement system. Data from 44 residents was included in the analysis with a linear mixed model. Although analysis revealed no statistically significant effects, results indicate that the use of a monitoring system can guide nurses in organizing their tasks to increase effectiveness. Information systems such as the mobility monitor can help to identify single outliers that do not correspond with the overall situation. In the health care system, problematic individual cases can account for a disproportionally high cost levels. It was shown that information systems can have a significant economic impact in the long run. The study is registered at the German Clinical Trials Register under the Nr. DRKS00006829 .

  1. FIREMON: Fire effects monitoring and inventory system

    Treesearch

    Duncan C. Lutes; Robert E. Keane; John F. Caratti; Carl H. Key; Nathan C. Benson; Steve Sutherland; Larry J. Gangi

    2006-01-01

    Monitoring and inventory to assess the effects of wildland fire is critical for 1) documenting fire effects, 2) assessing ecosystem damage and benefit, 3) evaluating the success or failure of a burn, and 4) appraising the potential for future treatments. However, monitoring fire effects is often difficult because data collection requires abundant funds, resources, and...

  2. A computerized assessment to compare the impact of standard, stereoscopic, and high-definition laparoscopic monitor displays on surgical technique.

    PubMed

    Feng, Chuan; Rozenblit, Jerzy W; Hamilton, Allan J

    2010-11-01

    Surgeons performing laparoscopic surgery have strong biases regarding the quality and nature of the laparoscopic video monitor display. In a comparative study, we used a unique computerized sensing and analysis system to evaluate the various types of monitors employed in laparoscopic surgery. We compared the impact of different types of monitor displays on an individual's performance of a laparoscopic training task which required the subject to move the instrument to a set of targets. Participants (varying from no laparoscopic experience to board-certified surgeons) were asked to perform the assigned task while using all three display systems, which were randomly assigned: a conventional laparoscopic monitor system (2D), a high-definition monitor system (HD), and a stereoscopic display (3D). The effects of monitor system on various performance parameters (total time consumed to finish the task, average speed, and movement economy) were analyzed by computer. Each of the subjects filled out a subjective questionnaire at the end of their training session. A total of 27 participants completed our study. Performance with the HD monitor was significantly slower than with either the 3D or 2D monitor (p < 0.0001). Movement economy with the HD monitor was significantly reduced compared with the 3D (p < 0.0004) or 2D (p < 0.0001) monitor. In terms of average time required to complete the task, performance with the 3D monitor was significantly faster than with the HD (p < 0.0001) or 2D (p < 0.0086) monitor. However, the HD system was the overwhelming favorite according to subjective evaluation. Computerized sensing and analysis is capable of quantitatively assessing the seemingly minor effect of monitor display on surgical training performance. The study demonstrates that, while users expressed a decided preference for HD systems, actual quantitative analysis indicates that HD monitors offer no statistically significant advantage and may even worsen performance compared with standard 2D or 3D laparoscopic monitors.

  3. The development of control and monitoring system on marine current renewable energy Case study: strait of Toyapakeh - Nusa Penida, Bali

    NASA Astrophysics Data System (ADS)

    Arief, I. S.; Suherman, I. H.; Wardani, A. Y.; Baidowi, A.

    2017-05-01

    Control and monitoring system is a continuous process of securing the asset in the Marine Current Renewable Energy. A control and monitoring system is existed each critical components which is embedded in Failure Mode Effect Analysis (FMEA) method. As the result, the process in this paper developed through a matrix sensor. The matrix correlated to critical components and monitoring system which supported by sensors to conduct decision-making.

  4. Antipsychotic Cardiometabolic Side Effect Monitoring in a State Community Mental Health System.

    PubMed

    Cotes, Robert O; de Nesnera, Alex; Kelly, Michael; Orsini, Karen; Xie, Haiyi; McHugo, Greg; Bartels, Stephen; Brunette, Mary F

    2015-08-01

    Antipsychotic medications can cause serious cardiometabolic side effects. No recent research has broadly evaluated monitoring and strategies to improve monitoring in U.S. public mental health systems. To address this knowledge gap, we evaluated education with audit and feedback to leaders to improve cardiometabolic monitoring in a state mental health system. We used Chi square statistics and logistic regressions to explore changes in monitoring recorded in randomly sampled records over 2 years. In 2009, assessment of patients on antipsychotics was 29.6 % for cholesterol, 40.4 % for glucose, 29.1 % for triglycerides, 54.3 % for weight, 33.6 % for blood pressure, and 5.7 % for abdominal girth. In 2010, four of ten mental health centers improved their rate of adult laboratory monitoring. Overall monitoring in the state did not increase. Education for prescribers with audit and feedback to leaders can improve monitoring in some settings, but more intensive and/or prolonged interventions may be required.

  5. A wireless portable system with microsensors for monitoring respiratory diseases.

    PubMed

    Cao, Zhe; Zhu, Rong; Que, Rui-Yi

    2012-11-01

    A wireless portable monitoring system for respiratory diseases using microsensors is proposed. The monitoring system consists of two sensor nodes integrating with Bluetooth transmitters that measure user's respiratory airflow, blood oxygen saturation, and body posture. The utility of micro-hot-film flow sensor makes the monitor can acquire comprehensive respiration parameters which are useful for diagnoses of obstructive sleep apnea, chronic obstructive pulmonary disease, and asthma. The system can serve as both sleep recorder and spirometer. Additionally, a mobile phone or a PC connected to the Internet serving as a monitoring and transfer terminal makes telemedicine achievable. Several experiments were conducted to verify the feasibility and effectiveness of the proposed system for monitoring and diagnosing OSA, COPD, and asthma.

  6. Non-contact and Unrestrained Respiration Monitoring System for Sleeping Person Using Near-infrared Bright Spots Matrix Irradiation

    NASA Astrophysics Data System (ADS)

    Aoki, Hirooki; Aoki, Hiroichi; Nakajima, Masato

    Measurement of biological information appears to be an effective method to obtain an understanding of health conditions measures to maintain and improve the health of elderly people. However, every conventional bioinstrumentation technique imposes a sense of restraint that results in aversion against measurements that would last over consecutive days. To solve this problem, we propose a system for monitoring the respiration of sleepers, and it uses a fiber grating vision sensor, which is a type of optical range finder, to achieve non-contact and unrestrained monitoring. The signals obtained by the system include the respiration rate, shifts of the ventilation, and the body movement interval of the sleeper. The information enables to investigate the stability of the sleeper throughout the night. We examined the measuring accuracy, validity, and effectiveness of our proposed system. And all-night monitoring performed at elderly care facility revealed that respiratory disturbances during sleep occurred in many of the residents and that sleep apnea is a common syndrome, especially among residents who have senile dementia or have had a stroke. We were able to carry out the all-night monitoring with this system for a total of about 370 times, according to our schedule, without experiencing any failure, accident, or interruption. Our proposed system is highly effective for monitoring elderly dementia patients who are likely to become uncooperative during measurement with existing monitoring methods that use certain amounts of restraint.

  7. Secured network sensor-based defense system

    NASA Astrophysics Data System (ADS)

    Wei, Sixiao; Shen, Dan; Ge, Linqiang; Yu, Wei; Blasch, Erik P.; Pham, Khanh D.; Chen, Genshe

    2015-05-01

    Network sensor-based defense (NSD) systems have been widely used to defend against cyber threats. Nonetheless, if the adversary finds ways to identify the location of monitor sensors, the effectiveness of NSD systems can be reduced. In this paper, we propose both temporal and spatial perturbation based defense mechanisms to secure NSD systems and make the monitor sensor invisible to the adversary. The temporal-perturbation based defense manipulates the timing information of published data so that the probability of successfully recognizing monitor sensors can be reduced. The spatial-perturbation based defense dynamically redeploys monitor sensors in the network so that the adversary cannot obtain the complete information to recognize all of the monitor sensors. We carried out experiments using real-world traffic traces to evaluate the effectiveness of our proposed defense mechanisms. Our data shows that our proposed defense mechanisms can reduce the attack accuracy of recognizing detection sensors.

  8. Monitoring the Effectiveness of the Wilson Reading System for Students with Disabilities: One District's Example

    ERIC Educational Resources Information Center

    Stebbins, Molly S.; Stormont, Melissa; Lembke, Erica S.; Wilson, David J.; Clippard, Dana

    2012-01-01

    The current study detailed the manner in which one school district monitored the effectiveness of the Wilson Reading System for students with disabilities who were experiencing difficulty with reading. Effectiveness was measured by growth in the reading skills that have been documented to be critical for successful readers. Twenty fourth- and…

  9. [Development of wireless monitoring system based on Zigbee technology in blood and bacterin cold chain].

    PubMed

    Zhao, Peng; Sun, Jian-Jun; Wu, Tai-Hu

    2008-11-01

    Real-time monitoring for temperature is required in cold chain for the medical products that are sensible with temperature, such as blood and bacterin, to guarantee the quality and reduce their wastage. This wireless monitoring system in cold chain is developed with Zigbee technology. Functions such as real-time monitoring, analyzing, alarming are realized. The system boasts such characteristics as low power consumption, low cost, big capacity and high reliability, and could improve the capability of real-time monitoring and management in cold chain effectively.

  10. [Research and implementation of a real-time monitoring system for running status of medical monitors based on the internet of things].

    PubMed

    Li, Yiming; Qian, Mingli; Li, Long; Li, Bin

    2014-07-01

    This paper proposed a real-time monitoring system for running status of medical monitors based on the internet of things. In the aspect of hardware, a solution of ZigBee networks plus 470 MHz networks is proposed. In the aspect of software, graphical display of monitoring interface and real-time equipment failure alarm is implemented. The system has the function of remote equipment failure detection and wireless localization, which provides a practical and effective method for medical equipment management.

  11. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems.

    PubMed

    Katz, Laurence B; Macleod, Kirsty; Grady, Mike; Cameron, Hilary; Pfützner, Andreas; Setford, Steven

    2015-05-01

    Accurate self-monitoring of blood glucose is a key component of effective self-management of glycemic control. Accurate self-monitoring of blood glucose results are required for optimal insulin dosing and detection of hypoglycemia. However, blood glucose monitoring systems may be susceptible to error from test strip, user, environmental and pharmacological factors. This report evaluated 5 blood glucose monitoring systems that each use Verio glucose test strips for precision, effect of hematocrit and interferences in laboratory testing, and lay user and system accuracy in clinical testing according to the guidelines in ISO15197:2013(E). Performance of OneTouch(®) VerioVue™ met or exceeded standards described in ISO15197:2013 for precision, hematocrit performance and interference testing in a laboratory setting. Performance of OneTouch(®) Verio IQ™, OneTouch(®) Verio Pro™, OneTouch(®) Verio™, OneTouch(®) VerioVue™ and Omni Pod each met or exceeded accuracy standards for user performance and system accuracy in a clinical setting set forth in ISO15197:2013(E).

  12. Integrating observation and statistical forecasts over sub-Saharan Africa to support Famine Early Warning

    USGS Publications Warehouse

    Funk, Chris; Verdin, James P.; Husak, Gregory

    2007-01-01

    Famine early warning in Africa presents unique challenges and rewards. Hydrologic extremes must be tracked and anticipated over complex and changing climate regimes. The successful anticipation and interpretation of hydrologic shocks can initiate effective government response, saving lives and softening the impacts of droughts and floods. While both monitoring and forecast technologies continue to advance, discontinuities between monitoring and forecast systems inhibit effective decision making. Monitoring systems typically rely on high resolution satellite remote-sensed normalized difference vegetation index (NDVI) and rainfall imagery. Forecast systems provide information on a variety of scales and formats. Non-meteorologists are often unable or unwilling to connect the dots between these disparate sources of information. To mitigate these problem researchers at UCSB's Climate Hazard Group, NASA GIMMS and USGS/EROS are implementing a NASA-funded integrated decision support system that combines the monitoring of precipitation and NDVI with statistical one-to-three month forecasts. We present the monitoring/forecast system, assess its accuracy, and demonstrate its application in food insecure sub-Saharan Africa.

  13. Performance Analysis of Retrofitted Tribo-Corrosion Test Rig for Monitoring In Situ Oil Conditions.

    PubMed

    Siddaiah, Arpith; Khan, Zulfiqar Ahmad; Ramachandran, Rahul; Menezes, Pradeep L

    2017-09-28

    Oils and lubricants, once extracted after use from a mechanical system, can hardly be reused, and should be refurbished or replaced in most applications. New methods of in situ oil and lubricant efficiency monitoring systems have been introduced for a wide variety of mechanical systems, such as automobiles, aerospace aircrafts, ships, offshore wind turbines, and deep sea oil drilling rigs. These methods utilize electronic sensors to monitor the "byproduct effects" in a mechanical system that are not indicative of the actual remaining lifecycle and reliability of the oils. A reliable oil monitoring system should be able to monitor the wear rate and the corrosion rate of the tribo-pairs due to the inclusion of contaminants. The current study addresses this technological gap, and presents a novel design of a tribo-corrosion test rig for oils used in a dynamic system. A pin-on-disk tribometer test rig retrofitted with a three electrode-potentiostat corrosion monitoring system was used to analyze the corrosion and wear rate of a steel tribo-pair in industrial grade transmission oil. The effectiveness of the retrofitted test rig was analyzed by introducing various concentrations of contaminants in an oil medium that usually leads to a corrosive working environment. The results indicate that the retrofitted test rig can effectively monitor the in situ tribological performance of the oil in a controlled dynamic corrosive environment. It is a useful method to understand the wear-corrosion synergies for further experimental work, and to develop accurate predictive lifecycle assessment and prognostic models. The application of this system is expected to have economic benefits and help reduce the ecological oil waste footprint.

  14. Design and implementation of temperature and humidity monitoring system for poultry farm

    NASA Astrophysics Data System (ADS)

    Purnomo, Hindriyanto Dwi; Somya, Ramos; Fibriani, Charitas; Purwoko, Angga; Sadiyah, Ulfa

    2016-10-01

    Automatic monitoring system gains significant interest in poultry industry due to the need of consistent environment condition. Appropriate environment increase the feed conversion ratio as well as birds productivity. This will increase the competitiveness of the poultry industry. In this research, a temperature and humidity monitoring system is proposed to observer the temperature and relative humidity of a poultry house. The system is intended to be applied in the poultry industry with partnership schema. The proposed system is equipped with CCTV for visual monitoring. The measured temperature and humidity implement wireless sensor network technology. The experiment results reveals that proposed system have the potential to increase the effectiveness of monitoring of poultry house in poultry industry with partnership schema.

  15. Gas House Autonomous System Monitoring

    NASA Technical Reports Server (NTRS)

    Miller, Luke; Edsall, Ashley

    2015-01-01

    Gas House Autonomous System Monitoring (GHASM) will employ Integrated System Health Monitoring (ISHM) of cryogenic fluids in the High Pressure Gas Facility at Stennis Space Center. The preliminary focus of development incorporates the passive monitoring and eventual commanding of the Nitrogen System. ISHM offers generic system awareness, adept at using concepts rather than specific error cases. As an enabler for autonomy, ISHM provides capabilities inclusive of anomaly detection, diagnosis, and abnormality prediction. Advancing ISHM and Autonomous Operation functional capabilities enhances quality of data, optimizes safety, improves cost effectiveness, and has direct benefits to a wide spectrum of aerospace applications.

  16. Behavioral-Progress Monitoring Using the Electronic Daily Behavioral Report Card (e-DBRC) System

    ERIC Educational Resources Information Center

    Burke, Mack D.; Vannest, Kimberly J.

    2008-01-01

    In this article, the authors present an overview of a Web-based electronic system for behavioral-progress monitoring. Behavioral-progress monitoring is necessary to evaluate responsiveness to behavioral interventions, the effects of positive behavioral support, and the attainment of individualized education program goals and objectives. The…

  17. Operational Monitoring of GOME-2 and IASI Level 1 Product Processing at EUMETSAT

    NASA Astrophysics Data System (ADS)

    Livschitz, Yakov; Munro, Rosemary; Lang, Rüdiger; Fiedler, Lars; Dyer, Richard; Eisinger, Michael

    2010-05-01

    The growing complexity of operational level 1 radiance products from Low Earth Orbiting (LEO) platforms like EUMETSATs Metop series makes near-real-time monitoring of product quality a challenging task. The main challenge is to provide a monitoring system which is flexible and robust enough to identify and to react to anomalies which may be previously unknown to the system, as well as to provide all means and parameters necessary in order to support efficient ad-hoc analysis of the incident. The operational monitoring system developed at EUMETSAT for monitoring of GOME-2 and IASI level 1 data allows to perform near-real-time monitoring of operational products and instrument's health in a robust and flexible fashion. For effective information management, the system is based on a relational database (Oracle). An Extract, Transform, Load (ETL) process transforms products in EUMETSAT Polar System (EPS) format into relational data structures. The identification of commonalities between products and instruments allows for a database structure design in such a way that different data can be analyzed using the same business intelligence functionality. An interactive analysis software implementing modern data mining techniques is also provided for a detailed look into the data. The system is effectively used for day-to-day monitoring, long-term reporting, instrument's degradation analysis as well as for ad-hoc queries in case of an unexpected instrument or processing behaviour. Having data from different sources on a single instrument and even from different instruments, platforms or numerical weather prediction within the same database allows effective cross-comparison and looking for correlated parameters. Automatic alarms raised by checking for deviation of certain parameters, for data losses and other events significantly reduce time, necessary to monitor the processing on a day-to-day basis.

  18. Operational Monitoring of GOME-2 and IASI Level 1 Product Processing at EUMETSAT

    NASA Astrophysics Data System (ADS)

    Livschitz, Y.; Munro, R.; Lang, R.; Fiedler, L.; Dyer, R.; Eisinger, M.

    2009-12-01

    The growing complexity of operational level 1 radiance products from Low Earth Orbiting (LEO) platforms like EUMETSATs Metop series makes near-real-time monitoring of product quality a challenging task. The main challenge is to provide a monitoring system which is flexible and robust enough to identify and to react to anomalies which may be previously unknown to the system, as well as to provide all means and parameters necessary in order to support efficient ad-hoc analysis of the incident. The operational monitoring system developed at EUMETSAT for monitoring of GOME-2 and IASI level 1 data allows to perform near-real-time monitoring of operational products and instrument’s health in a robust and flexible fashion. For effective information management, the system is based on a relational database (Oracle). An Extract, Transform, Load (ETL) process transforms products in EUMETSAT Polar System (EPS) format into relational data structures. The identification of commonalities between products and instruments allows for a database structure design in such a way that different data can be analyzed using the same business intelligence functionality. An interactive analysis software implementing modern data mining techniques is also provided for a detailed look into the data. The system is effectively used for day-to-day monitoring, long-term reporting, instrument’s degradation analysis as well as for ad-hoc queries in case of an unexpected instrument or processing behaviour. Having data from different sources on a single instrument and even from different instruments, platforms or numerical weather prediction within the same database allows effective cross-comparison and looking for correlated parameters. Automatic alarms raised by checking for deviation of certain parameters, for data losses and other events significantly reduce time, necessary to monitor the processing on a day-to-day basis.

  19. Engine health monitoring: An advanced system

    NASA Technical Reports Server (NTRS)

    Dyson, R. J. E.

    1981-01-01

    The advanced propulsion monitoring system is described. The system was developed in order to fulfill a growing need for effective engine health monitoring. This need is generated by military requirements for increased performance and efficiency in more complex propulsion systems, while maintaining or improving the cost to operate. This program represents a vital technological step in the advancement of the state of the art for monitoring systems in terms of reliability, flexibility, accuracy, and provision of user oriented results. It draws heavily on the technology and control theory developed for modern, complex, electronically controlled engines and utilizes engine information which is a by-product of such a system.

  20. A reliable low cost integrated wireless sensor network for water quality monitoring and level control system in UAE

    NASA Astrophysics Data System (ADS)

    Abou-Elnour, Ali; Khaleeq, Hyder; Abou-Elnour, Ahmad

    2016-04-01

    In the present work, wireless sensor network and real-time controlling and monitoring system are integrated for efficient water quality monitoring for environmental and domestic applications. The proposed system has three main components (i) the sensor circuits, (ii) the wireless communication system, and (iii) the monitoring and controlling unit. LabView software has been used in the implementation of the monitoring and controlling system. On the other hand, ZigBee and myRIO wireless modules have been used to implement the wireless system. The water quality parameters are accurately measured by the present computer based monitoring system and the measurement results are instantaneously transmitted and published with minimum infrastructure costs and maximum flexibility in term of distance or location. The mobility and durability of the proposed system are further enhanced by fully powering via a photovoltaic system. The reliability and effectiveness of the system are evaluated under realistic operating conditions.

  1. Modeling of human movement monitoring using Bluetooth Low Energy technology.

    PubMed

    Mokhtari, G; Zhang, Q; Karunanithi, M

    2015-01-01

    Bluetooth Low Energy (BLE) is a wireless communication technology which can be used to monitor human movements. In this monitoring system, a BLE signal scanner scans signal strength of BLE tags carried by people, to thus infer human movement patterns within its monitoring zone. However to the extent of our knowledge one main aspect of this monitoring system which has not yet been thoroughly investigated in literature is how to build a sound theoretical model, based on tunable BLE communication parameters such as scanning time interval and advertising time interval, to enable the study and design of effective and efficient movement monitoring systems. In this paper, we proposed and developed a statistical model based on Monte-Carlo simulation, which can be utilized to assess impacts of BLE technology parameters in terms of latency and efficiency, on a movement monitoring system, and can thus benefit a more efficient system design.

  2. An assessment of seismic monitoring in the United States; requirement for an Advanced National Seismic System

    USGS Publications Warehouse

    ,

    1999-01-01

    This report assesses the status, needs, and associated costs of seismic monitoring in the United States. It sets down the requirement for an effective, national seismic monitoring strategy and an advanced system linking national, regional, and urban monitoring networks. Modernized seismic monitoring can provide alerts of imminent strong earthquake shaking; rapid assessment of distribution and severity of earthquake shaking (for use in emergency response); warnings of a possible tsunami from an offshore earthquake; warnings of volcanic eruptions; information for correctly characterizing earthquake hazards and for improving building codes; and data on response of buildings and structures during earthquakes, for safe, cost-effective design, engineering, and construction practices in earthquake-prone regions.

  3. A UAV-Mounted Whole Cell Biosensor System for Environmental Monitoring Applications

    PubMed Central

    Lu, Yi; Macias, Dominique; Dean, Zachary S.; Kreger, Nicole R.; Wong, Pak Kin

    2016-01-01

    This study reports the development of a portable whole cell biosensor system for environmental monitoring applications, such as air quality control, water pollution monitoring and radiation leakage detection. The system consists of a lightweight mechanical housing, a temperature regulating system, and a microfluidic bacterial inoculation channel. The overall system, which is less than 200 g, serves as a portable incubator for cell inoculation and can be mounted on an unmanned aerial vehicle for monitoring remote and unreachable locations. The feedback control system maintains the inoculation temperature within 0.05 degree Celsius. The large surface-to-volume ratio of the polydimethylsiloxane microchannel facilitates effective gas exchange for rapid bacterial growth. Molecular dynamic simulation shows effective diffusion of major gas pollutants in PDMS toward gas sensing applications. By optimizing the design, we demonstrate the operation of the system in ambient temperatures from 5°C to 32°C and rapid bacterial growth in microchannels compared to standard bacterial culture techniques. PMID:26584498

  4. Space-Derived Sewer Monitor

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The QuadraScan Longterm Flow Monitoring System is a second generation sewer monitor developed by American Digital Systems, Inc.'s founder Peter Petroff. Petroff, a former spacecraft instrumentation designer at Marshall Space Flight Center, used expertise based on principles acquired in Apollo and other NASA programs. QuadraScan borrows even more heavily from space technology, for example in its data acquisition and memory system derived from NASA satellites. "One-time" measurements are often plagued with substantial errors due to the flow of groundwater absorbed into the system. These system sizing errors stem from a basic informational deficiency: accurate, reliable data on how much water flows through a sewer system over a long period of time is very difficult to obtain. City officials are turning to "permanent," or long-term sewer monitoring systems. QuadraScan offers many advantages to city officials such as the early warning capability to effectively plan for city growth in order to avoid the crippling economic impact of bans on new sewer connections in effect in many cities today.

  5. Monitoring Effective Doses Received By Air Crews With A Space Weather Application

    NASA Astrophysics Data System (ADS)

    Lantos, P.

    To fulfil new requirements of the European Community concerning monitoring of effective doses received by air crews, the French Aviation Authority has developed an operational system called Sievert. The SIEVERT system is analysed as an exam- ple of Space Weather application. One of its characteristics is to calculate the dose received on-board each flight on the basis of the specific and detailled flight given by companies. Operational models will be used. As input to the models, the system needs monitoring of galactic cosmic rays and of solar flare particles. The French neu- tron monitors located in Kerguelen Islands (South Indian Ocean) and Terre Adélie (Antarctica) will be used for this purpose. Particular attention will be devoted to evo- lution of the system in conjunction with new measurements available in the frame of a permanent validation process.

  6. Real-Time Two-Dimensional Magnetic Particle Imaging for Electromagnetic Navigation in Targeted Drug Delivery.

    PubMed

    Le, Tuan-Anh; Zhang, Xingming; Hoshiar, Ali Kafash; Yoon, Jungwon

    2017-09-07

    Magnetic nanoparticles (MNPs) are effective drug carriers. By using electromagnetic actuated systems, MNPs can be controlled noninvasively in a vascular network for targeted drug delivery (TDD). Although drugs can reach their target location through capturing schemes of MNPs by permanent magnets, drugs delivered to non-target regions can affect healthy tissues and cause undesirable side effects. Real-time monitoring of MNPs can improve the targeting efficiency of TDD systems. In this paper, a two-dimensional (2D) real-time monitoring scheme has been developed for an MNP guidance system. Resovist particles 45 to 65 nm in diameter (5 nm core) can be monitored in real-time (update rate = 2 Hz) in 2D. The proposed 2D monitoring system allows dynamic tracking of MNPs during TDD and renders magnetic particle imaging-based navigation more feasible.

  7. Real-Time Two-Dimensional Magnetic Particle Imaging for Electromagnetic Navigation in Targeted Drug Delivery

    PubMed Central

    Le, Tuan-Anh; Zhang, Xingming; Hoshiar, Ali Kafash; Yoon, Jungwon

    2017-01-01

    Magnetic nanoparticles (MNPs) are effective drug carriers. By using electromagnetic actuated systems, MNPs can be controlled noninvasively in a vascular network for targeted drug delivery (TDD). Although drugs can reach their target location through capturing schemes of MNPs by permanent magnets, drugs delivered to non-target regions can affect healthy tissues and cause undesirable side effects. Real-time monitoring of MNPs can improve the targeting efficiency of TDD systems. In this paper, a two-dimensional (2D) real-time monitoring scheme has been developed for an MNP guidance system. Resovist particles 45 to 65 nm in diameter (5 nm core) can be monitored in real-time (update rate = 2 Hz) in 2D. The proposed 2D monitoring system allows dynamic tracking of MNPs during TDD and renders magnetic particle imaging-based navigation more feasible. PMID:28880220

  8. Ice Detector and Deicing Fluid Effectiveness Monitoring System

    NASA Technical Reports Server (NTRS)

    Seegmiller, H. Lee B. (Inventor)

    1996-01-01

    An ice detector and deicing fluid effectiveness monitoring system for an aircraft is disclosed. The ice detection portion is particularly suited for use in flight to notify the flight crew of an accumulation of ice on an aircraft lifting and control surfaces, or helicopter rotors, whereas the deicing fluid effectiveness monitoring portion is particularly suited for use on the ground to notify the flight crew of the possible loss of the effectiveness of the deicing fluid. The ice detection portion comprises a temperature sensor and a parallel arrangement of electrodes whose coefficient of coupling is indicative of the formation of the ice, as well as the thickness of the formed ice. The fluid effectiveness monitoring portion comprises a temperature sensor and an ionic-conduction cell array that measures the conductivity of the deicing fluid which is indicative of its concentration and, thus, its freezing point. By measuring the temperature and having knowledge of the freezing point of the deicing fluid, the fluid effectiveness monitoring portion predicts when the deicing fluid may lose its effectiveness because its freezing point may correspond to the temperature of the ambient.

  9. Performance-based financing as a health system reform: mapping the key dimensions for monitoring and evaluation.

    PubMed

    Witter, Sophie; Toonen, Jurrien; Meessen, Bruno; Kagubare, Jean; Fritsche, György; Vaughan, Kelsey

    2013-09-29

    Performance-based financing is increasingly being applied in a variety of contexts, with the expectation that it can improve the performance of health systems. However, while there is a growing literature on implementation issues and effects on outputs, there has been relatively little focus on interactions between PBF and health systems and how these should be studied. This paper aims to contribute to filling that gap by developing a framework for assessing the interactions between PBF and health systems, focusing on low and middle income countries. In doing so, it elaborates a general framework for monitoring and evaluating health system reforms in general. This paper is based on an exploratory literature review and on the work of a group of academics and PBF practitioners. The group developed ideas for the monitoring and evaluation framework through exchange of emails and working documents. Ideas were further refined through discussion at the Health Systems Research symposium in Beijing in October 2012, through comments from members of the online PBF Community of Practice and Beijing participants, and through discussion with PBF experts in Bergen in June 2013. The paper starts with a discussion of definitions, to clarify the core concept of PBF and how the different terms are used. It then develops a framework for monitoring its interactions with the health system, structured around five domains of context, the development process, design, implementation and effects. Some of the key questions for monitoring and evaluation are highlighted, and a systematic approach to monitoring effects proposed, structured according to the health system pillars, but also according to inputs, processes and outputs. The paper lays out a broad framework within which indicators can be prioritised for monitoring and evaluation of PBF or other health system reforms. It highlights the dynamic linkages between the domains and the different pillars. All of these are also framed within inter-sectoral and wider societal contexts. It highlights the importance of differentiating short term and long term effects, and also effects (intended and unintended) at different levels of the health system, and for different sectors and areas of the country. Outstanding work will include using and refining the framework and agreeing on the most important hypotheses to test using it, in relation to PBF but also other purchasing and provider payment reforms, as well as appropriate research methods to use for this task.

  10. Validation of Procedures for Monitoring Crewmember Immune Function - Short Duration Biological Investigation

    NASA Technical Reports Server (NTRS)

    Sams, Clarence; Crucian, Brian; Stowe, Raymond; Pierson, Duane; Mehta, Satish; Morukov, Boris; Uchakin, Peter; Nehlsen-Cannarella, Sandra

    2008-01-01

    Validation of Procedures for Monitoring Crew Member Immune Function - Short Duration Biological Investigation (Integrated Immune-SDBI) will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flightcompatible immune monitoring strategy. Immune system changes will be monitored by collecting and analyzing blood, urine and saliva samples from crewmembers before, during and after space flight.

  11. The Gardiola landslide: evolution and reactivation threshold definition through eight years of continuous monitoring activity

    NASA Astrophysics Data System (ADS)

    Allasia, P.; Baldo, M.; Giordan, D.; Lollino, G.

    2009-04-01

    Following heavy rainfalls and due to the particular meteo-climatic conditions occurred on October 16th, 2000, the north western part of Italy was interested by widespread landslides and flood phenomena. In particular a landslide phenomenon was triggered along the left side of Val Germanasca that exposed the Provincial Road No. 169 to risk. The extent of the unstable volume (about 700,000 cubic meters) could have led, in case of failure, to a natural damming of the valley that could have been followed by a dam-break flood. Thus the urgent need to monitor the evolving phenomenon and to assess all the available actions to be taken in order to mitigate the risk. After the installation of a first provisional monitoring system, a permanent monitoring system, able to follow the phenomenon evolution, was set up. The system was progressively expanded and it is still running. The monitoring network is made up of an automatic total station and a network of wire - extensometers. This coupled measuring system was designed to make monitoring possible even in bad atmospheric conditions Then the monitoring network was expanded with the addition of a borehole inclinometer and a piezometer. Continuous monitoring brings added value for both emergencies management and the study of the dynamical evolution of the phenomenon. As far as phenomena that are subject to seasonal reactivations are concerned, the use of monitoring systems brings a significant improvement of knowledge. This proves to be even more useful during the risk mitigation phase than during the study of the evolutionary trends of the phenomena. The case of Gardiola demonstrated how a careful analysis of the phenomenon makes possible an effective management of the most critical moments, together with a careful design of effective and not expensive mitigation works. Data provided by the monitoring system allowed the realisation of less expensive and less invasive facilities that work only during the acme of the phenomenon. On the contrary the monitoring system allows a careful surveillance during the year, which increases in case of heavy rainfalls. This system is therefore effective in order to manage and get through critical phases, when it may be necessary a continuous monitoring. Moreover, the large amount of data gathered in eight years of continuous monitoring, has been used to define a relationships between displacements and rainfalls and to recognise a new landslide sector now particular active.

  12. Mobile Delivery of Treatment for Alcohol Use Disorders

    PubMed Central

    Quanbeck, Andrew; Chih, Ming-Yuan; Isham, Andrew; Johnson, Roberta; Gustafson, David

    2014-01-01

    Several systems for treating alcohol-use disorders (AUDs) exist that operate on mobile phones. These systems are categorized into four groups: text-messaging monitoring and reminder systems, text-messaging intervention systems, comprehensive recovery management systems, and game-based systems. Text-messaging monitoring and reminder systems deliver reminders and prompt reporting of alcohol consumption, enabling continuous monitoring of alcohol use. Text-messaging intervention systems additionally deliver text messages designed to promote abstinence and recovery. Comprehensive recovery management systems use the capabilities of smart-phones to provide a variety of tools and services that can be tailored to individuals, including in-the-moment assessments and access to peer discussion groups. Game-based systems engage the user using video games. Although many commercial applications for treatment of AUDs exist, few (if any) have empirical evidence of effectiveness. The available evidence suggests that although texting-based applications may have beneficial effects, they are probably insufficient as interventions for AUDs. Comprehensive recovery management systems have the strongest theoretical base and have yielded the strongest and longest-lasting effects, but challenges remain, including cost, understanding which features account for effects, and keeping up with technological advances. PMID:26259005

  13. Automated Iodine Monitoring System Development (AIMS). [shuttle prototype

    NASA Technical Reports Server (NTRS)

    1975-01-01

    The operating principle of the automated iodine monitoring/controller system (AIMS) is described along with several design modifications. The iodine addition system is also discussed along with test setups and calibration; a facsimile of the optical/mechanical portion of the iodine monitor was fabricated and tested. The appendices include information on shuttle prototype AIMS, preliminary prime item development specifications, preliminary failure modes and effects analysis, and preliminary operating and maintenance instructions.

  14. Safety Evaluation of an Automated Remote Monitoring System for Heart Failure in an Urban, Indigent Population.

    PubMed

    Gross-Schulman, Sandra; Sklaroff, Laura Myerchin; Hertz, Crystal Coyazo; Guterman, Jeffrey J

    2017-12-01

    Heart Failure (HF) is the most expensive preventable condition, regardless of patient ethnicity, race, socioeconomic status, sex, and insurance status. Remote telemonitoring with timely outpatient care can significantly reduce avoidable HF hospitalizations. Human outreach, the traditional method used for remote monitoring, is effective but costly. Automated systems can potentially provide positive clinical, fiscal, and satisfaction outcomes in chronic disease monitoring. The authors implemented a telephonic HF automated remote monitoring system that utilizes deterministic decision tree logic to identify patients who are at risk of clinical decompensation. This safety study evaluated the degree of clinical concordance between the automated system and traditional human monitoring. This study focused on a broad underserved population and demonstrated a safe, reliable, and inexpensive method of monitoring patients with HF.

  15. Tuning quantum measurements to control chaos.

    PubMed

    Eastman, Jessica K; Hope, Joseph J; Carvalho, André R R

    2017-03-20

    Environment-induced decoherence has long been recognised as being of crucial importance in the study of chaos in quantum systems. In particular, the exact form and strength of the system-environment interaction play a major role in the quantum-to-classical transition of chaotic systems. In this work we focus on the effect of varying monitoring strategies, i.e. for a given decoherence model and a fixed environmental coupling, there is still freedom on how to monitor a quantum system. We show here that there is a region between the deep quantum regime and the classical limit where the choice of the monitoring parameter allows one to control the complex behaviour of the system, leading to either the emergence or suppression of chaos. Our work shows that this is a result from the interplay between quantum interference effects induced by the nonlinear dynamics and the effectiveness of the decoherence for different measurement schemes.

  16. Metric Ranking of Invariant Networks with Belief Propagation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tao, Changxia; Ge, Yong; Song, Qinbao

    The management of large-scale distributed information systems relies on the effective use and modeling of monitoring data collected at various points in the distributed information systems. A promising approach is to discover invariant relationships among the monitoring data and generate invariant networks, where a node is a monitoring data source (metric) and a link indicates an invariant relationship between two monitoring data. Such an invariant network representation can help system experts to localize and diagnose the system faults by examining those broken invariant relationships and their related metrics, because system faults usually propagate among the monitoring data and eventually leadmore » to some broken invariant relationships. However, at one time, there are usually a lot of broken links (invariant relationships) within an invariant network. Without proper guidance, it is difficult for system experts to manually inspect this large number of broken links. Thus, a critical challenge is how to effectively and efficiently rank metrics (nodes) of invariant networks according to the anomaly levels of metrics. The ranked list of metrics will provide system experts with useful guidance for them to localize and diagnose the system faults. To this end, we propose to model the nodes and the broken links as a Markov Random Field (MRF), and develop an iteration algorithm to infer the anomaly of each node based on belief propagation (BP). Finally, we validate the proposed algorithm on both realworld and synthetic data sets to illustrate its effectiveness.« less

  17. Program evaluation of remote heart failure monitoring: healthcare utilization analysis in a rural regional medical center.

    PubMed

    Riley, William T; Keberlein, Pamela; Sorenson, Gigi; Mohler, Sailor; Tye, Blake; Ramirez, A Susana; Carroll, Mark

    2015-03-01

    Remote monitoring for heart failure (HF) has had mixed and heterogeneous effects across studies, necessitating further evaluation of remote monitoring systems within specific healthcare systems and their patient populations. "Care Beyond Walls and Wires," a wireless remote monitoring program to facilitate patient and care team co-management of HF patients, served by a rural regional medical center, provided the opportunity to evaluate the effects of this program on healthcare utilization. Fifty HF patients admitted to Flagstaff Medical Center (Flagstaff, AZ) participated in the project. Many of these patients lived in underserved and rural communities, including Native American reservations. Enrolled patients received mobile, broadband-enabled remote monitoring devices. A matched cohort was identified for comparison. HF patients enrolled in this program showed substantial and statistically significant reductions in healthcare utilization during the 6 months following enrollment, and these reductions were significantly greater compared with those who declined to participate but not when compared with a matched cohort. The findings from this project indicate that a remote HF monitoring program can be successfully implemented in a rural, underserved area. Reductions in healthcare utilization were observed among program participants, but reductions were also observed among a matched cohort, illustrating the need for rigorous assessment of the effects of HF remote monitoring programs in healthcare systems.

  18. Monitoring the Effective and Efficient Use of Land: The English Approach

    NASA Astrophysics Data System (ADS)

    Ganser, Robin

    In England quantified targets for the reuse of brownfields and of existing buildings place particular requirements on the planning system as part of the overall strategy to make effective use of natural resources. Achieving these targets is not free of obstacles and potential conflicts. Therefore monitoring of policy implementation is a necessity in the planning system.

  19. 76 FR 11713 - Revisions to the Unregulated Contaminant Monitoring Regulation (UCMR 3) for Public Water Systems

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-03

    ... subject to possible selection for virus monitoring. If selected, these systems would be required to permit... selection of 800 small PWSs serving 10,000 or fewer people monitored for List 1 contaminants. This... health effects and occurrence data EPA used to make these selections are contained in ``Possible...

  20. Introducing a new monitoring manual for home fortification and strengthening capacity to monitor nutrition interventions.

    PubMed

    Jefferds, Maria Elena D; Flores-Ayala, Rafael

    2015-12-01

    Lack of monitoring capacity is a key barrier for nutrition interventions and limits programme management, decision making and programme effectiveness in many low-income and middle-income countries. A 2011 global assessment reported lack of monitoring capacity was the top barrier for home fortification interventions, such as micronutrient powders or lipid-based nutrient supplements. A Manual for Developing and Implementing Monitoring Systems for Home Fortification Interventions was recently disseminated. It is comprehensive and describes monitoring concepts and frameworks and includes monitoring tools and worksheets. The monitoring manual describes the steps of developing and implementing a monitoring system for home fortification interventions, including identifying and engaging stakeholders; developing a programme description including logic model and logical framework; refining the purpose of the monitoring system, identifying users and their monitoring needs; describing the design of the monitoring system; developing indicators; describing the core components of a comprehensive monitoring plan; and considering factors related to stage of programme development, sustainability and scale up. A fictional home fortification example is used throughout the monitoring manual to illustrate these steps. The monitoring manual is a useful tool to support the development and implementation of home fortification intervention monitoring systems. In the context of systematic capacity gaps to design, implement and monitor nutrition interventions in many low-income and middle-income countries, the dissemination of new tools, such as monitoring manuals may have limited impact without additional attention to strengthening other individual, organisational and systems levels capacities. Published 2014. This article is a U.S. Government work and is in the public domain in the USA.

  1. The efficacy and stability of an information and communication technology-based centralized monitoring system of adherence to immunosuppressive medication in kidney transplant recipients: study protocol for a randomized controlled trial.

    PubMed

    Jung, Hee-Yeon; Seong, Sook Jin; Choi, Ji-Young; Cho, Jang-Hee; Park, Sun-Hee; Kim, Chan-Duck; Yoon, Young-Ran; Kim, Hyung-Kee; Huh, Seung; Yoon, Se-Hee; Lee, Jong Soo; Kim, Yong-Lim

    2017-10-16

    Immunosuppression non-adherence in kidney transplant recipients (KTRs) not only increases the risk of medical intervention due to acute rejection and graft loss but burdens the socioeconomic system in the form of increased healthcare costs. An aggressive preemptive effort by healthcare professionals, geared to ensure adherence to immunosuppressants in KTRs, is significant and imperative. This study was designed as a prospective, open-label, multicenter, randomized controlled study aimed at evaluating the efficacy and stability of an information and communication technology (ICT)-based centralized monitoring system in boosting medication adherence in KTRs. One hundred fourteen KTRs registered throughout the year 2017 to 2018 are randomized into either the ICT-based centralized home monitoring system or to ambulatory follow-up. The planned follow-up duration is 6 months. The ICT-based centralized home monitoring system described consists of a smart pill box equipped with personal identification system, a home monitoring system, an electronic Case Report Form (eCRF) system, and a comprehensive clinical trial management system (CTMS). It alerts both patients and medical staff with texts and pill box alarms if there is a dosage/dosing time error or a missed dose. Medication adherence and transplant outcomes for the follow-up period are compared between the two groups, while patient satisfaction as well as the stability and cost-effectiveness of the ICT-based monitoring system are to be evaluated. This on-going study is expected to determine if consistent use of the ICT-based centralized monitoring system described could maximize mediation adherence and subsequently enhance transplant outcomes in KTRs. Further, it would lay the foundation for successful implementation of this ICT-based monitoring system for effective management of medication adherence in KTRs. ClinicalTrials.gov, Identifier: NCT03136588 . Registered on 20 April 2017.

  2. Microfabricated Hydrogen Sensor Technology for Aerospace and Commercial Applications

    NASA Technical Reports Server (NTRS)

    Hunter, Gary W.; Bickford, R. L.; Jansa, E. D.; Makel, D. B.; Liu, C. C.; Wu, Q. H.; Powers, W. T.

    1994-01-01

    Leaks on the Space Shuttle while on the Launch Pad have generated interest in hydrogen leak monitoring technology. An effective leak monitoring system requires reliable hydrogen sensors, hardware, and software to monitor the sensors. The system should process the sensor outputs and provide real-time leak monitoring information to the operator. This paper discusses the progress in developing such a complete leak monitoring system. Advanced microfabricated hydrogen sensors are being fabricated at Case Western Reserve University (CWRU) and tested at NASA Lewis Research Center (LeRC) and Gencorp Aerojet (Aerojet). Changes in the hydrogen concentrations are detected using a PdAg on silicon Schottky diode structure. Sensor temperature control is achieved with a temperature sensor and heater fabricated onto the sensor chip. Results of the characterization of these sensors are presented. These sensors can detect low concentrations of hydrogen in inert environments with high sensitivity and quick response time. Aerojet is developing the hardware and software for a multipoint leak monitoring system designed to provide leak source and magnitude information in real time. The monitoring system processes data from the hydrogen sensors and presents the operator with a visual indication of the leak location and magnitude. Work has commenced on integrating the NASA LeRC-CWRU hydrogen sensors with the Aerojet designed monitoring system. Although the leak monitoring system was designed for hydrogen propulsion systems, the possible applications of this monitoring system are wide ranged. Possible commercialization of the system will also be discussed.

  3. Cost-effective and monitoring-active technique for TDM-passive optical networks

    NASA Astrophysics Data System (ADS)

    Chi, Chang-Chia; Lin, Hong-Mao; Tarn, Chen-Wen; Lin, Huang-Liang

    2014-08-01

    A reliable, detection-active and cost-effective method which employs the hello and heartbeat signals for branched node distinguishing to monitor fiber fault in any branch of distribution fibers of a time division multiplexing passive optical network (TDM-PON) is proposed. With this method, the material cost of building an optical network monitor system for a TDM-PON with 168 ONUs and the time of identifying a multiple branch faults is significantly reduced in a TDM-PON system of any scale. A fault location in a 1 × 32 TDM-PON system using this method to identify the fault branch is demonstrated.

  4. Development of a cost-effective and flexible vibration DAQ system for long-term continuous structural health monitoring

    NASA Astrophysics Data System (ADS)

    Nguyen, Theanh; Chan, Tommy H. T.; Thambiratnam, David P.; King, Les

    2015-12-01

    In the structural health monitoring (SHM) field, long-term continuous vibration-based monitoring is becoming increasingly popular as this could keep track of the health status of structures during their service lives. However, implementing such a system is not always feasible due to on-going conflicts between budget constraints and the need of sophisticated systems to monitor real-world structures under their demanding in-service conditions. To address this problem, this paper presents a comprehensive development of a cost-effective and flexible vibration DAQ system for long-term continuous SHM of a newly constructed institutional complex with a special focus on the main building. First, selections of sensor type and sensor positions are scrutinized to overcome adversities such as low-frequency and low-level vibration measurements. In order to economically tackle the sparse measurement problem, a cost-optimized Ethernet-based peripheral DAQ model is first adopted to form the system skeleton. A combination of a high-resolution timing coordination method based on the TCP/IP command communication medium and a periodic system resynchronization strategy is then proposed to synchronize data from multiple distributed DAQ units. The results of both experimental evaluations and experimental-numerical verifications show that the proposed DAQ system in general and the data synchronization solution in particular work well and they can provide a promising cost-effective and flexible alternative for use in real-world SHM projects. Finally, the paper demonstrates simple but effective ways to make use of the developed monitoring system for long-term continuous structural health evaluation as well as to use the instrumented building herein as a multi-purpose benchmark structure for studying not only practical SHM problems but also synchronization related issues.

  5. Design of cold chain logistics remote monitoring system based on ZigBee and GPS location

    NASA Astrophysics Data System (ADS)

    Zong, Xiaoping; Shao, Heling

    2017-03-01

    This paper designed a remote monitoring system based on Bee Zig wireless sensor network and GPS positioning, according to the characteristics of cold chain logistics. The system consisted of the ZigBee network, gateway and monitoring center. ZigBee network temperature acquisition modules and GPS positioning acquisition module were responsible for data collection, and then send the data to the host computer through the GPRS network and Internet to realize remote monitoring of vehicle with functions of login permissions, temperature display, latitude and longitude display, historical data, real-time alarm and so on. Experiments showed that the system is stable, reliable and effective to realize the real-time remote monitoring of the vehicle in the process of cold chain transport.

  6. On possibilities of using global monitoring in effective prevention of tailings storage facilities failures.

    PubMed

    Stefaniak, Katarzyna; Wróżyńska, Magdalena

    2018-02-01

    Protection of common natural goods is one of the greatest challenges man faces every day. Extracting and processing natural resources such as mineral deposits contributes to the transformation of the natural environment. The number of activities designed to keep balance are undertaken in accordance with the concept of integrated order. One of them is the use of comprehensive systems of tailings storage facility monitoring. Despite the monitoring, system failures still occur. The quantitative aspect of the failures illustrates both the scale of the problem and the quantitative aspect of the consequences of tailings storage facility failures. The paper presents vast possibilities provided by the global monitoring in the effective prevention of these failures. Particular attention is drawn to the potential of using multidirectional monitoring, including technical and environmental monitoring by the example of one of the world's biggest hydrotechnical constructions-Żelazny Most Tailings Storage Facility (TSF), Poland. Analysis of monitoring data allows to take preventive action against construction failures of facility dams, which can have devastating effects on human life and the natural environment.

  7. [The regional model of three-level system of of medical social monitoring of children and adolescents: the pilot project in the Republic of Tatarstan].

    PubMed

    Al'bitskii, V Iu; Ustinova, N V; Farrakhov, A Z; Shavaliev, R F; Kulikov O V; Plaksina, L V

    2014-01-01

    The absence of system of medical social monitoring of children being in difficult life situations is one of main causes of preventable losses of health and life of children and adolescents. The plan of activities of the working group No3 under the Coordination council under the President of the Russian Federation of the national strategy realization of actions in interest of children for 2012-2017 includes a point: "The development and implementation of standard model of medical social monitoring of children and adolescents in the subjects of the Russian Federation". The implementation of this task is assigned to the Department of social pediatrics of The research center of children health of Moscow and the Ministry of Health of the Republic of Tatarstan. The research methods included analysis and generalization of advanced experience of medical social monitoring of children population; expertise technique; modeling. The regional model of three-level system of medical social monitoring of children population is developed and implemented. The model includes level I (consulting rooms of medical social care of children polyclinics, feldsher obstetric stations, first-aid centers), level II--inter-municipal (departments of medical social monitoring in central district hospitals, medical institutions, clinical diagnostic centers) and level III--regional (the Republican center of medical social monitoring of children and adolescents). The immediate tasks necessary for effective functioning of system of medical social monitoring were determined. Within the framework of implementation of the pilot project the legal and normative legislative acts were developed to regulate functioning of regional model of three-level system of medical social care. The other documents necessary for effective functioning of this system were elaborated. The practical significance of this system is in the implementation of effective three-level model of medical social monitoring of children and adolescents supporting decrease of morbidity, mortality and "risk behaviors" suicidal included. The model is to prevent child neglect and homelessness and cruel treatment of children and adolescents.

  8. [Research and Implementation of Vital Signs Monitoring System Based on Cloud Platform].

    PubMed

    Yu, Man; Tan, Anzu; Huang, Jianqi

    2018-05-30

    Through analyzing the existing problems in the current mode, the vital signs monitoring information system based on cloud platform is designed and developed. The system's aim is to assist nurse carry out vital signs nursing work effectively and accurately. The system collects, uploads and analyzes patient's vital signs data by PDA which connecting medical inspection equipments. Clinical application proved that the system can effectively improve the quality and efficiency of medical care and may reduce medical expenses. It is alse an important practice result to build a medical cloud platform.

  9. Gun Launch System: efficient and low-cost means of research and real-time monitoring

    NASA Astrophysics Data System (ADS)

    Degtyarev, Alexander; Ventskovsky, Oleg; Korostelev, Oleg; Yakovenko, Peter; Kanevsky, Valery; Tselinko, Alexander

    2005-08-01

    The Gun Launch System with a reusable sub-orbital launch vehicle as a central element is proposed by a consortium of several Ukrainian high-tech companies as an effective, fast-response and low-cost means of research and real-time monitoring. The system is described in details, with the emphasis on its most important advantages. Multiple applications of the system are presented, including ones for the purposes of microgravity research; chemical, bacteriological and radiation monitoring and research of atmosphere and ionosphere; operational monitoring of natural and man-made disasters, as well as for some other areas of great practical interest. The current level of the system development is given, and the way ahead towards full system's implementation is prescribed.

  10. Mobile Phone Based System Opportunities to Home-based Managing of Chemotherapy Side Effects.

    PubMed

    Davoodi, Somayeh; Mohammadzadeh, Zeinab; Safdari, Reza

    2016-06-01

    Applying mobile base systems in cancer care especially in chemotherapy management have remarkable growing in recent decades. Because chemotherapy side effects have significant influences on patient's lives, therefore it is necessary to take ways to control them. This research has studied some experiences of using mobile phone based systems to home-based monitor of chemotherapy side effects in cancer. In this literature review study, search was conducted with keywords like cancer, chemotherapy, mobile phone, information technology, side effects and self managing, in Science Direct, Google Scholar and Pub Med databases since 2005. Today, because of the growing trend of the cancer, we need methods and innovations such as information technology to manage and control it. Mobile phone based systems are the solutions that help to provide quick access to monitor chemotherapy side effects for cancer patients at home. Investigated studies demonstrate that using of mobile phones in chemotherapy management have positive results and led to patients and clinicians satisfactions. This study shows that the mobile phone system for home-based monitoring chemotherapy side effects works well. In result, knowledge of cancer self-management and the rate of patient's effective participation in care process improved.

  11. [Intelligent watch system for health monitoring based on Bluetooth low energy technology].

    PubMed

    Wang, Ji; Guo, Hailiang; Ren, Xiaoli

    2017-08-01

    According to the development status of wearable technology and the demand of intelligent health monitoring, we studied the multi-function integrated smart watches solution and its key technology. First of all, the sensor technology with high integration density, Bluetooth low energy (BLE) and mobile communication technology were integrated and used in develop practice. Secondly, for the hardware design of the system in this paper, we chose the scheme with high integration density and cost-effective computer modules and chips. Thirdly, we used real-time operating system FreeRTOS to develop the friendly graphical interface interacting with touch screen. At last, the high-performance application software which connected with BLE hardware wirelessly and synchronized data was developed based on android system. The function of this system included real-time calendar clock, telephone message, address book management, step-counting, heart rate and sleep quality monitoring and so on. Experiments showed that the collecting data accuracy of various sensors, system data transmission capacity, the overall power consumption satisfy the production standard. Moreover, the system run stably with low power consumption, which could realize intelligent health monitoring effectively.

  12. Automated terrestrial laser scanning with near-real-time change detection - monitoring of the Séchilienne landslide

    NASA Astrophysics Data System (ADS)

    Kromer, Ryan A.; Abellán, Antonio; Hutchinson, D. Jean; Lato, Matt; Chanut, Marie-Aurelie; Dubois, Laurent; Jaboyedoff, Michel

    2017-05-01

    We present an automated terrestrial laser scanning (ATLS) system with automatic near-real-time change detection processing. The ATLS system was tested on the Séchilienne landslide in France for a 6-week period with data collected at 30 min intervals. The purpose of developing the system was to fill the gap of high-temporal-resolution TLS monitoring studies of earth surface processes and to offer a cost-effective, light, portable alternative to ground-based interferometric synthetic aperture radar (GB-InSAR) deformation monitoring. During the study, we detected the flux of talus, displacement of the landslide and pre-failure deformation of discrete rockfall events. Additionally, we found the ATLS system to be an effective tool in monitoring landslide and rockfall processes despite missing points due to poor atmospheric conditions or rainfall. Furthermore, such a system has the potential to help us better understand a wide variety of slope processes at high levels of temporal detail.

  13. Designing personal exercise monitoring employing multiple modes of delivery: implications from a qualitative study on heart rate monitoring.

    PubMed

    Segerståhl, Katarina; Oinas-Kukkonen, Harri

    2011-12-01

    Various personal monitoring technologies have been introduced for supporting regular physical activity, which is of critical importance in reducing the risks of several chronic diseases. Recent studies suggest that combining multiple modes of delivery, such as text messages and mobile monitoring devices with web applications, holds potential for effectively supporting physical exercise. Of particular interest is how the functionality and content of these systems should be distributed across the different modes for successful outcomes. The aim of this study was to: (a) investigate how users incorporate a system employing two modes of delivery - a wearable heart rate monitor and a web service - into their training and (b) to analyze benefits and limitations in personal exercise monitoring and how they relate to the different modes in use. A qualitative field study employing diaries and semi-structured interviews was carried out with 30 participants who used a heart rate monitoring system comprising a wearable heart rate monitor, Polar FT60 and a web service, Polar Personal Trainer for a period of 21 days. The data were systematically analyzed to identify specific benefits and limitations associated with the system characteristics and modes as perceived by the end-users. The benefits include supporting exploratory learning, controlling target behavior, rectifying behaviors, motivation and logging support. The limitations are associated with information for validating the system, virtual coaching, task-technology fit, data integrity and privacy concerns. Mobile interfaces enable exploratory learning and controlling of target behaviors in situ, while web services can effectively support users' need for cognition within the early stages of adoption and long-term training with intelligent coaching functionality. This study explains several benefits and limitations in personal exercise monitoring. These can be addressed with crossmedial design, i.e., strategic distribution of functionality and content across modes within the system. Our findings suggest that personal exercise monitoring systems may be improved by more systematically combining mobile and web-based functionality. 2011 Elsevier Ireland Ltd. All rights reserved.

  14. A Universal Noninvasive Continuous Blood Pressure Measurement System for Remote Healthcare Monitoring.

    PubMed

    Mukherjee, Ramtanu; Ghosh, Sanchita; Gupta, Bharat; Chakravarty, Tapas

    2018-01-22

    The effectiveness of any remote healthcare monitoring system depends on how much accurate, patient-friendly, versatile, and cost-effective measurement it is delivering. There has always been a huge demand for such a long-term noninvasive remote blood pressure (BP) measurement system, which could be used worldwide in the remote healthcare industry. Thus, noninvasive continuous BP measurement and remote monitoring have become an emerging area in the remote healthcare industry. Photoplethysmography-based (PPG) BP measurement is a continuous, unobtrusive, patient-friendly, and cost-effective solution. However, BP measurements through PPG sensors are not much reliable and accurate due to some major limitations like pressure disturbance, motion artifacts, and variations in human skin tone. A novel reflective PPG sensor has been developed to eliminate the abovementioned pressure disturbance and motion artifacts during the BP measurement. Considering the variations of the human skin tone across demography, a novel algorithm has been developed to make the BP measurement accurate and reliable. The training dataset captured 186 subjects' data and the trial dataset captured another new 102 subjects' data. The overall accuracy achieved by using the proposed method is nearly 98%. Thus, demonstrating the efficacy of the proposed method. The developed BP monitoring system is quite accurate, reliable, cost-effective, handy, and user friendly. It is also expected that this system would be quite useful to monitor the BP of infants, elderly people, patients having wounds, burn injury, or in the intensive care unit environment.

  15. Two visual systems in monitoring of dynamic traffic: effects of visual disruption.

    PubMed

    Zheng, Xianjun Sam; McConkie, George W

    2010-05-01

    Studies from neurophysiology and neuropsychology provide support for two separate object- and location-based visual systems, ventral and dorsal. In the driving context, a study was conducted using a change detection paradigm to explore drivers' ability to monitor the dynamic traffic flow, and the effects of visual disruption on these two visual systems. While driving, a discrete change, such as vehicle location, color, or identity, was occasionally made in one of the vehicles on the road ahead of the driver. Experiment results show that without visual disruption, all changes were detected very well; yet, these equally perceivable changes were disrupted differently by a brief blank display (150 ms): the detection of location changes was especially reduced. The disruption effects were also bigger for the parked vehicle compared to the moving ones. The findings support the different roles for two visual systems in monitoring the dynamic traffic: the "where", dorsal system, tracks vehicle spatiotemporal information on perceptual level, encoding information in a coarse and transient manner; whereas the "what", ventral system, monitors vehicles' featural information, encoding information more accurately and robustly. Both systems work together contributing to the driver's situation awareness of traffic. Benefits and limitations of using the driving simulation are also discussed. Copyright (c) 2009 Elsevier Ltd. All rights reserved.

  16. PIMACS (Polarimeter and improved modular anti-coincidence system): an effective instrument concept for x-, gamma-ray monitoring, and polarimetry measurements on the International Space Station

    NASA Astrophysics Data System (ADS)

    Stuffler, Timo; Graue, Roland; Bird, Antony J.; Dean, Antony; Staubert, Rüdiger

    2018-04-01

    This paper, "PIMACS (Polarimeter and improved modular anti-coincidence system): an effective instrument concept for x-, gamma-ray monitoring, and polarimetry measurements on the International Space Station," was presented as part of International Conference on Space Optics—ICSO 1997, held in Toulouse, France.

  17. Integrating environmental monitoring with cumulative effects management and decision making.

    PubMed

    Cronmiller, Joshua G; Noble, Bram F

    2018-05-01

    Cumulative effects (CE) monitoring is foundational to emerging regional and watershed CE management frameworks, yet monitoring is often poorly integrated with CE management and decision-making processes. The challenges are largely institutional and organizational, more so than scientific or technical. Calls for improved integration of monitoring with CE management and decision making are not new, but there has been limited research on how best to integrate environmental monitoring programs to ensure credible CE science and to deliver results that respond to the more immediate questions and needs of regulatory decision makers. This paper examines options for the integration of environmental monitoring with CE frameworks. Based on semistructured interviews with practitioners, regulators, and other experts in the Lower Athabasca, Alberta, Canada, 3 approaches to monitoring system design are presented. First, a distributed monitoring system, reflecting the current approach in the Lower Athabasca, where monitoring is delegated to different external programs and organizations; second, a 1-window system in which monitoring is undertaken by a single, in-house agency for the purpose of informing management and regulatory decision making; third, an independent system driven primarily by CE science and understanding causal relationships, with knowledge adopted for decision support where relevant to specific management questions. The strengths and limitations of each approach are presented. A hybrid approach may be optimal-an independent, nongovernment, 1-window model for CE science, monitoring, and information delivery-capitalizing on the strengths of distributed, 1-window, and independent monitoring systems while mitigating their weaknesses. If governments are committed to solving CE problems, they must invest in the long-term science needed to do so; at the same time, if science-based monitoring programs are to be sustainable over the long term, they must be responsive to the more immediate, often shorter term needs and CE information requirements of decision makers. Integr Environ Assess Manag 2018;14:407-417. © 2018 SETAC. © 2018 SETAC.

  18. Monitoring the tobacco use epidemic V: The environment: factors that influence tobacco use.

    PubMed

    Farrelly, Matthew C

    2009-01-01

    This environment paper (V of V) summarizes important surveillance and evaluation systems that monitor influences on tobacco use such as smoke-free laws and other legislation, excise taxes, mass media, and a broad range of tobacco control activities, discusses their strengths and weaknesses, and makes recommendations for enhancement. We summarize and expand on the recommendations from the Environment Working Group of the National Tobacco Monitoring, Research, and Evaluation Workshop prioritized surveillance needs. This group rank-ordered surveillance needs various environmental influences, considering both the perceived importance of each environmental influence and the adequacy of the current surveillance systems. Based on this ranking and subsequent discussion, the group identified key priorities for enhancement. The group arrived at two key priorities: (1) develop and implement a national system for local tobacco control ordinance surveillance, and (2) develop and implement a comprehensive program monitoring system that is used by all states and supported by all funding agencies. Other environmental influences recommended for priority monitoring include cigarette prices and tobacco countermarketing. Systematic surveillance and monitoring of key program inputs and outputs and environmental influences is central to understand the effectiveness and cost-effectiveness of tobacco control efforts.

  19. Monitoring long-term oral corticosteroids

    PubMed Central

    Mundell, Lewis; Lindemann, Roberta; Douglas, James

    2017-01-01

    Corticosteroids are synthetic analogues of human hormones normally produced by the adrenal cortex. They have both glucocorticoid and mineralocorticoid properties. The glucocortoid components are anti-inflammatory, immunosuppressive, anti-proliferative and vasoconstrictive. They influence the metabolism of carbohydrate and protein, in addition to playing a key role in the body’s stress response. Mineralocorticoid’s main significance is in the balance of salt and water concentrations. Due to the combination of these effects, corticosteroids can cause many adverse effects. Oral corticosteroids are absorbed systemically and are therefore more likely to cause adverse effects than topical or inhaled corticosteroids. Furthermore, it is assumed that greater duration of treatment will lead to a greater number of adverse effects, and therefore the most at risk group are those taking high dose, long-term oral corticosteroids (LTOC). High dose is defined as a prescription of >5 mg oral prednisolone and long term as duration of treatment >1 month (based on National Institute for Health and Care Excellence guidance for patient’s ’at risk' of systemic side effects). Parameters to be monitored in primary care include weight, blood pressure, triglycerides, glucose and urea and electrolytes. From clinical experience within the general practice setting, the authors propose that these patients do not receive adequate baseline monitoring before starting corticosteroids nor are these markers monitored consistently thereafter. This project intended to evidence this claim, evaluate the adverse effect profile and improve monitoring in this patient group. The initial audit of 22 patients, within a single general practice, detected at least one documented adverse effect in 64% of patients, while 41% reported more than one adverse effect. 45% had recorded weight gain, 18% had recorded osteoporosis, 18% had at least one recorded cataract, 14% had recorded Hypertension, 14% had recorded diabetes mellitus, 9% had recorded dyspepsia and 5% had a recorded psychiatric complaint. All of these recorded conditions were either directly attributed to steroid medication or occurred since LTOC were prescribed. The aim of this project was to increase the percentage of patients on LTOC with complete baseline monitoring to 100%. ’Baseline monitoring' was defined as a measurement taken within the previous 5 years. Although somewhat arbitrary, 5 years was felt to be the maximum timeframe in which monitoring would still be relevant for comparison following introduction of LTOC. Quality improvement methodology was used throughout this project with multiple PDSA (Plan, Study, Do and Act) cycles. Through this, a monitoring system and protocol for patients taking LTOC was developed. As a result of this project, five adverse effects were detected in five different patients. These included two cases of secondary hypertension, one case of diabetes mellitus, one cataract and one case of adrenal insufficiency. 12 out of 20 patients achieved complete baseline monitoring. While this study did not fully achieve its aim, the aim was deliberately ambitious. As not all patients in this study attended for monitoring, a figure of 100% was impossible to achieve. The remaining ’incompletely monitored patients' had some but not all parameters measured. The creation of a staff protocol and increased clinical experience will ensure that complete monitoring takes place in the future. In conclusion, this project has shown that adverse effects from LTOC are prevalent in a single general practice population. It is also shown that monitoring for LTOC adverse effects is inadequate but can be improved relatively easily as skills and competencies from other medication monitoring systems already exist within healthcare settings and are immediately transferable. PMID:29450303

  20. Monitoring long-term oral corticosteroids.

    PubMed

    Mundell, Lewis; Lindemann, Roberta; Douglas, James

    2017-01-01

    Corticosteroids are synthetic analogues of human hormones normally produced by the adrenal cortex. They have both glucocorticoid and mineralocorticoid properties. The glucocortoid components are anti-inflammatory, immunosuppressive, anti-proliferative and vasoconstrictive. They influence the metabolism of carbohydrate and protein, in addition to playing a key role in the body's stress response. Mineralocorticoid's main significance is in the balance of salt and water concentrations. Due to the combination of these effects, corticosteroids can cause many adverse effects. Oral corticosteroids are absorbed systemically and are therefore more likely to cause adverse effects than topical or inhaled corticosteroids. Furthermore, it is assumed that greater duration of treatment will lead to a greater number of adverse effects, and therefore the most at risk group are those taking high dose, long-term oral corticosteroids (LTOC). High dose is defined as a prescription of >5 mg oral prednisolone and long term as duration of treatment >1 month (based on National Institute for Health and Care Excellence guidance for patient's 'at risk' of systemic side effects). Parameters to be monitored in primary care include weight, blood pressure, triglycerides, glucose and urea and electrolytes. From clinical experience within the general practice setting, the authors propose that these patients do not receive adequate baseline monitoring before starting corticosteroids nor are these markers monitored consistently thereafter. This project intended to evidence this claim, evaluate the adverse effect profile and improve monitoring in this patient group. The initial audit of 22 patients, within a single general practice, detected at least one documented adverse effect in 64% of patients, while 41% reported more than one adverse effect. 45% had recorded weight gain, 18% had recorded osteoporosis, 18% had at least one recorded cataract, 14% had recorded Hypertension, 14% had recorded diabetes mellitus, 9% had recorded dyspepsia and 5% had a recorded psychiatric complaint. All of these recorded conditions were either directly attributed to steroid medication or occurred since LTOC were prescribed. The aim of this project was to increase the percentage of patients on LTOC with complete baseline monitoring to 100%. 'Baseline monitoring' was defined as a measurement taken within the previous 5 years. Although somewhat arbitrary, 5 years was felt to be the maximum timeframe in which monitoring would still be relevant for comparison following introduction of LTOC. Quality improvement methodology was used throughout this project with multiple PDSA (Plan, Study, Do and Act) cycles. Through this, a monitoring system and protocol for patients taking LTOC was developed. As a result of this project, five adverse effects were detected in five different patients. These included two cases of secondary hypertension, one case of diabetes mellitus, one cataract and one case of adrenal insufficiency. 12 out of 20 patients achieved complete baseline monitoring. While this study did not fully achieve its aim, the aim was deliberately ambitious. As not all patients in this study attended for monitoring, a figure of 100% was impossible to achieve. The remaining 'incompletely monitored patients' had some but not all parameters measured. The creation of a staff protocol and increased clinical experience will ensure that complete monitoring takes place in the future. In conclusion, this project has shown that adverse effects from LTOC are prevalent in a single general practice population. It is also shown that monitoring for LTOC adverse effects is inadequate but can be improved relatively easily as skills and competencies from other medication monitoring systems already exist within healthcare settings and are immediately transferable.

  1. Noninvasive and real-time monitoring of molecular targeting therapy for lymph node and peritoneal metastasis in nude mice bearing xenografts of human colorectal cancer cells tagged with GFP and DsRed

    NASA Astrophysics Data System (ADS)

    Nakanishi, Hayao; Hara, Masayasu; Ikehara, Yuzuru; Tatematsu, Masae

    2007-02-01

    We have developed an in vivo imaging system consisting of GFP- and DsRed-tagged human colonic cancer cell line, which has peritoneal and lymph node metastatic potential and show high sensitivity to EGFR targeting drugs, and convenient detection devices for GFP and DsRed. The latter includes a small handy fluorescence detection device for external monitoring of the therapeutic effect of the drug and a convenient stereo fluorescent microscope for internal visualization of micrometastases. We applied this imaging system to investigate anti-metastatic effects of EGFR targeting drugs such as gefitinib (Iressa). This system allowed sensitive detection of the development of peritoneal and lymph node metastases from the micrometastasis stage at the cellular level and also permited noninvasive, non-anesthetic monitoring of anti-metastatic effect of the drug in an animal facility without any pretreatment. Significant decreases in the intraabdominal metastatic tumor growth and prevention of inguinal lymph node metastasis by gefitinib treatment could be clearly monitored. These results suggest that convenient, low-cost, true real-time monitoring of therapeutic effect using such a fluorescence-mediated whole body imaging system seems to enhance the speed of preclinical study for novel anti-cancer agents and will allow us to understand the action mechanism of molecular targeting drugs.

  2. A Non-Invasive Deep Tissue PH Monitor.

    DTIC Science & Technology

    1995-08-11

    disturbances in acid-base regulation may have serious effects on metabolic activity, circulation, and the central nervous system. Currently, acid-base...to tissue ischemia than is arterial pH. Consequently, a non-invasive deep tissue pH monitor has enormous value as a mechanism for rapid and effective ...achieved, and improve our understanding of what physical effects are important to successful non-invasive deep tissue pH monitoring. This last statement

  3. Performance-based financing as a health system reform: mapping the key dimensions for monitoring and evaluation

    PubMed Central

    2013-01-01

    Background Performance-based financing is increasingly being applied in a variety of contexts, with the expectation that it can improve the performance of health systems. However, while there is a growing literature on implementation issues and effects on outputs, there has been relatively little focus on interactions between PBF and health systems and how these should be studied. This paper aims to contribute to filling that gap by developing a framework for assessing the interactions between PBF and health systems, focusing on low and middle income countries. In doing so, it elaborates a general framework for monitoring and evaluating health system reforms in general. Methods This paper is based on an exploratory literature review and on the work of a group of academics and PBF practitioners. The group developed ideas for the monitoring and evaluation framework through exchange of emails and working documents. Ideas were further refined through discussion at the Health Systems Research symposium in Beijing in October 2012, through comments from members of the online PBF Community of Practice and Beijing participants, and through discussion with PBF experts in Bergen in June 2013. Results The paper starts with a discussion of definitions, to clarify the core concept of PBF and how the different terms are used. It then develops a framework for monitoring its interactions with the health system, structured around five domains of context, the development process, design, implementation and effects. Some of the key questions for monitoring and evaluation are highlighted, and a systematic approach to monitoring effects proposed, structured according to the health system pillars, but also according to inputs, processes and outputs. Conclusions The paper lays out a broad framework within which indicators can be prioritised for monitoring and evaluation of PBF or other health system reforms. It highlights the dynamic linkages between the domains and the different pillars. All of these are also framed within inter-sectoral and wider societal contexts. It highlights the importance of differentiating short term and long term effects, and also effects (intended and unintended) at different levels of the health system, and for different sectors and areas of the country. Outstanding work will include using and refining the framework and agreeing on the most important hypotheses to test using it, in relation to PBF but also other purchasing and provider payment reforms, as well as appropriate research methods to use for this task. PMID:24073625

  4. A web-based GPS system for displacement monitoring and failure mechanism analysis of reservoir landslide.

    PubMed

    Li, Yuanyao; Huang, Jinsong; Jiang, Shui-Hua; Huang, Faming; Chang, Zhilu

    2017-12-07

    It is important to monitor the displacement time series and to explore the failure mechanism of reservoir landslide for early warning. Traditionally, it is a challenge to monitor the landslide displacements real-timely and automatically. Globe Position System (GPS) is considered as the best real-time monitoring technology, however, the accuracies of the landslide displacements monitored by GPS are not assessed effectively. A web-based GPS system is developed to monitor the landslide displacements real-timely and automatically in this study. And the discrete wavelet transform (DWT) is proposed to assess the accuracy of the GPS monitoring displacements. Wangmiao landslide in Three Gorges Reservoir area in China is used as case study. The results show that the web-based GPS system has advantages of high precision, real-time, remote control and automation for landslide monitoring; the Root Mean Square Errors of the monitoring landslide displacements are less than 5 mm. Meanwhile, the results also show that a rapidly falling reservoir water level can trigger the reactivation of Wangmiao landslide. Heavy rainfall is also an important factor, but not a crucial component.

  5. An Embedded Wireless Sensor Network with Wireless Power Transmission Capability for the Structural Health Monitoring of Reinforced Concrete Structures.

    PubMed

    Gallucci, Luca; Menna, Costantino; Angrisani, Leopoldo; Asprone, Domenico; Moriello, Rosario Schiano Lo; Bonavolontà, Francesco; Fabbrocino, Francesco

    2017-11-07

    Maintenance strategies based on structural health monitoring can provide effective support in the optimization of scheduled repair of existing structures, thus enabling their lifetime to be extended. With specific regard to reinforced concrete (RC) structures, the state of the art seems to still be lacking an efficient and cost-effective technique capable of monitoring material properties continuously over the lifetime of a structure. Current solutions can typically only measure the required mechanical variables in an indirect, but economic, manner, or directly, but expensively. Moreover, most of the proposed solutions can only be implemented by means of manual activation, making the monitoring very inefficient and then poorly supported. This paper proposes a structural health monitoring system based on a wireless sensor network (WSN) that enables the automatic monitoring of a complete structure. The network includes wireless distributed sensors embedded in the structure itself, and follows the monitoring-based maintenance (MBM) approach, with its ABCDE paradigm, namely: accuracy, benefit, compactness, durability, and easiness of operations. The system is structured in a node level and has a network architecture that enables all the node data to converge in a central unit. Human control is completely unnecessary until the periodic evaluation of the collected data. Several tests are conducted in order to characterize the system from a metrological point of view and assess its performance and effectiveness in real RC conditions.

  6. What's working, what's not: The monitoring and reporting system for Tasmania's national parks and reserves

    Treesearch

    Glenys Jones

    2015-01-01

    This paper describes the Australian State of Tasmania's management effectiveness Monitoring and Reporting System for national parks and reserves. This jurisdictional performance measurement system is designed to provide all interested parties with reliable factual information and measured evidence about reserve management achievements, progress and challenges. Key...

  7. Performance Analysis of Retrofitted Tribo-Corrosion Test Rig for Monitoring In Situ Oil Conditions

    PubMed Central

    Ramachandran, Rahul; Menezes, Pradeep L.

    2017-01-01

    Oils and lubricants, once extracted after use from a mechanical system, can hardly be reused, and should be refurbished or replaced in most applications. New methods of in situ oil and lubricant efficiency monitoring systems have been introduced for a wide variety of mechanical systems, such as automobiles, aerospace aircrafts, ships, offshore wind turbines, and deep sea oil drilling rigs. These methods utilize electronic sensors to monitor the “byproduct effects” in a mechanical system that are not indicative of the actual remaining lifecycle and reliability of the oils. A reliable oil monitoring system should be able to monitor the wear rate and the corrosion rate of the tribo-pairs due to the inclusion of contaminants. The current study addresses this technological gap, and presents a novel design of a tribo-corrosion test rig for oils used in a dynamic system. A pin-on-disk tribometer test rig retrofitted with a three electrode-potentiostat corrosion monitoring system was used to analyze the corrosion and wear rate of a steel tribo-pair in industrial grade transmission oil. The effectiveness of the retrofitted test rig was analyzed by introducing various concentrations of contaminants in an oil medium that usually leads to a corrosive working environment. The results indicate that the retrofitted test rig can effectively monitor the in situ tribological performance of the oil in a controlled dynamic corrosive environment. It is a useful method to understand the wear–corrosion synergies for further experimental work, and to develop accurate predictive lifecycle assessment and prognostic models. The application of this system is expected to have economic benefits and help reduce the ecological oil waste footprint. PMID:28956819

  8. The measurement procedure in the SEMONT monitoring system.

    PubMed

    Djuric, Nikola; Kljajic, Dragan; Kasas-Lazetic, Karolina; Bajovic, Vera

    2014-03-01

    The measurement procedure of the open area in situ electric field strength is presented, acquiring the real field data for testing of the Serbian electromagnetic field monitoring network (SEMONT) and its Internet portal. The SEMONT monitoring system introduces an advanced approach of wireless sensor network utilization for the continuous supervision of overall and cumulative level of electromagnetic field over the observed area. The aim of the SEMONT system is to become a useful tool for the national and municipal agencies for the environmental protection, regarding the electromagnetic pollution monitoring and the exposure assessment of the general population. Considering the public concern on the potentially harmful effects of the long-term exposure to electromagnetic radiation, as well as the public transparency principle that is incorporated into the Serbian law on non-ionizing radiation protection, the SEMONT monitoring system is designed for the long-term continuous monitoring, presenting real-time measurement results, and corresponding exposure assessment over the public Internet network.

  9. Real-time long term measurement using integrated framework for ubiquitous smart monitoring

    NASA Astrophysics Data System (ADS)

    Heo, Gwanghee; Lee, Giu; Lee, Woosang; Jeon, Joonryong; Kim, Pil-Joong

    2007-04-01

    Ubiquitous monitoring combining internet technologies and wireless communication is one of the most promising technologies of infrastructure health monitoring against the natural of man-made hazards. In this paper, an integrated framework of the ubiquitous monitoring is developed for real-time long term measurement in internet environment. This framework develops a wireless sensor system based on Bluetooth technology and sends measured acceleration data to the host computer through TCP/IP protocol. And it is also designed to respond to the request of web user on real time basis. In order to verify this system, real time monitoring tests are carried out on a prototype self-anchored suspension bridge. Also, wireless measurement system is analyzed to estimate its sensing capacity and evaluate its performance for monitoring purpose. Based on the evaluation, this paper proposes the effective strategies for integrated framework in order to detect structural deficiencies and to design an early warning system.

  10. The Gas Monitoring of the Besiii Drift Chamber

    NASA Astrophysics Data System (ADS)

    Wang, Xianggao; Chen, Chang; Chen, Yuanbo; Wu, Zhi; Gu, Yunting; Ma, Xiaoyan; Jin, Yan; Liu, Rongguang; Tang, Xiao; Wang, Lan; Zhu, Qiming

    Two monitoring proportional counters (MPCs), installed at the inlet and outlet of the gas system of BESIII drift chamber (DC), were used to monitor the operation of the BESIII DC successfully and effectively as reported in this paper. The ratio of Gout/Gin (full energy photoelectron peak position of 55Fe 5.9 keV X-ray in inlet MPC as Gin and outlet MPC as Gout) is used as the main monitoring parameter. The MPC method is very useful for the gas detector system.

  11. Heat Stress Monitor

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The heavy, cumbersome body protection suits worn by members of hazardous materials response teams cause marked elevation of body temperatures, which can reduce effectiveness and lead to heat stress and injury. The CorTemp System, marketed by Human Technologies, Inc., provides the basis for a body temperature monitoring alarm system. Encased in a three-quarter-inch ingestible capsule, the system includes a mini-thermometer, miniature telemetry system, a microbattery and temperature sensor. It makes its way through the digestive system, continuously monitoring temperature. Findings are sent to the recorder by telemetry, and then displayed and stored for transfer to a computer.

  12. Effective utilization of data from the Highway Performance Monitoring System.

    DOT National Transportation Integrated Search

    1984-01-01

    The objective of this research was to investigate the potential uses of the annual submittal and output data that result from the Highway Performance Monitoring System (HPMS), to determine what the data needs and uses of the Virginia Department of Hi...

  13. Performance Monitoring Applied to System Supervision

    PubMed Central

    Somon, Bertille; Campagne, Aurélie; Delorme, Arnaud; Berberian, Bruno

    2017-01-01

    Nowadays, automation is present in every aspect of our daily life and has some benefits. Nonetheless, empirical data suggest that traditional automation has many negative performance and safety consequences as it changed task performers into task supervisors. In this context, we propose to use recent insights into the anatomical and neurophysiological substrates of action monitoring in humans, to help further characterize performance monitoring during system supervision. Error monitoring is critical for humans to learn from the consequences of their actions. A wide variety of studies have shown that the error monitoring system is involved not only in our own errors, but also in the errors of others. We hypothesize that the neurobiological correlates of the self-performance monitoring activity can be applied to system supervision. At a larger scale, a better understanding of system supervision may allow its negative effects to be anticipated or even countered. This review is divided into three main parts. First, we assess the neurophysiological correlates of self-performance monitoring and their characteristics during error execution. Then, we extend these results to include performance monitoring and error observation of others or of systems. Finally, we provide further directions in the study of system supervision and assess the limits preventing us from studying a well-known phenomenon: the Out-Of-the-Loop (OOL) performance problem. PMID:28744209

  14. Model-based design and experimental verification of a monitoring concept for an active-active electromechanical aileron actuation system

    NASA Astrophysics Data System (ADS)

    Arriola, David; Thielecke, Frank

    2017-09-01

    Electromechanical actuators have become a key technology for the onset of power-by-wire flight control systems in the next generation of commercial aircraft. The design of robust control and monitoring functions for these devices capable to mitigate the effects of safety-critical faults is essential in order to achieve the required level of fault tolerance. A primary flight control system comprising two electromechanical actuators nominally operating in active-active mode is considered. A set of five signal-based monitoring functions are designed using a detailed model of the system under consideration which includes non-linear parasitic effects, measurement and data acquisition effects, and actuator faults. Robust detection thresholds are determined based on the analysis of parametric and input uncertainties. The designed monitoring functions are verified experimentally and by simulation through the injection of faults in the validated model and in a test-rig suited to the actuation system under consideration, respectively. They guarantee a robust and efficient fault detection and isolation with a low risk of false alarms, additionally enabling the correct reconfiguration of the system for an enhanced operational availability. In 98% of the performed experiments and simulations, the correct faults were detected and confirmed within the time objectives set.

  15. Vaccine safety monitoring systems in developing countries: an example of the Vietnam model.

    PubMed

    Ali, Mohammad; Rath, Barbara; Thiem, Vu Dinh

    2015-01-01

    Only few health intervention programs have been as successful as vaccination programs with respect to preventing morbidity and mortality in developing countries. However, the success of a vaccination program is threatened by rumors and misunderstanding about the risks of vaccines. It is short-sighted to plan the introduction of vaccines into developing countries unless effective vaccine safety monitoring systems are in place. Such systems that track adverse events following immunization (AEFI) is currently lacking in most developing countries. Therefore, any rumor may affect the entire vaccination program. Public health authorities should implement the safety monitoring system of vaccines, and disseminate safety issues in a proactive mode. Effective safety surveillance systems should allow for the conduct of both traditional and alternative epidemiologic studies through the use of prospective data sets. The vaccine safety data link implemented in Vietnam in mid-2002 indicates that it is feasible to establish a vaccine safety monitoring system for the communication of vaccine safety in developing countries. The data link provided the investigators an opportunity to evaluate AEFI related to measles vaccine. Implementing such vaccine safety monitoring system is useful in all developing countries. The system should be able to make objective and clear communication regarding safety issues of vaccines, and the data should be reported to the public on a regular basis for maintaining their confidence in vaccination programs.

  16. Hardware Specific Integration Strategy for Impedance-Based Structural Health Monitoring of Aerospace Systems

    NASA Technical Reports Server (NTRS)

    Owen, Robert B.; Gyekenyesi, Andrew L.; Inman, Daniel J.; Ha, Dong S.

    2011-01-01

    The Integrated Vehicle Health Management (IVHM) Project, sponsored by NASA's Aeronautics Research Mission Directorate, is conducting research to advance the state of highly integrated and complex flight-critical health management technologies and systems. An effective IVHM system requires Structural Health Monitoring (SHM). The impedance method is one such SHM technique for detection and monitoring complex structures for damage. This position paper on the impedance method presents the current state of the art, future directions, applications and possible flight test demonstrations.

  17. A longitudinal, randomized, and prospective study of nocturnal monitoring in children and adolescents with epilepsy: Effects on quality of life and sleep.

    PubMed

    Borusiak, Peter; Bast, Thomas; Kluger, Gerhard; Weidenfeld, Andrea; Langer, Thorsten; Jenke, Andreas C W; Wiegand, Gert

    2016-08-01

    Most studies on seizure detection systems focus more on the effectiveness of devices than on their practicability in and impact on everyday life. Our study investigated the impact of a technical monitoring system on subjective quality of sleep and the lives of affected families. Furthermore, we evaluated the impact of anxiety levels on seizure monitoring and vice versa. Forty-three patients with newly diagnosed epilepsy were included. Initially, the families decided whether they did (group 1, n=27) or did not (group 2, n=16) want to use a monitoring device. In group 1, patients were randomly assigned to using Epi-Care® (group 1A, n=14) or an audio baby monitor (group 1B, n=13). Quality of life was assessed at two points (t1, at the start of the study and t2, at 5-7months of follow-up) using the SF-12, Kindl-R, and "Familien-Belastungs-Fragebogen" (German version of the "Impact on Family Scale"). In addition, parental anxiety was measured using the State-Trait Anxiety-Inventory, and subjective quality of sleep was measured using the Pittsburgh Sleep Quality Index. Statistical analysis focused on the possible differences between groups 1 and 2 that may influence parents' decisions and the effects of the presence and types of technical monitoring over time. Anxiety levels were not significantly different between the groups with and without monitoring (group 1 vs. group 2). We also found no statistically significant, substantial baseline differences between the Epi-Care® and audio baby monitor groups, with at least medium effect sizes (group 1A vs. group 1B). Parents' health-related mental quality of life measured via the SF-12 increased significantly over time in all groups. By tendency, the fear of further seizures as well as the frequency of cosleeping arrangements in the monitoring group decreased during the study and approached the stable values of the control group. Individual parental anxiety levels are not crucial in the decision regarding the use of a monitoring device. A monitoring system may help some families in certain aspects of daily life. During the first months following a diagnosis of epilepsy, quality of life increases independently of the use of a monitoring system. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. The effect of health payment reforms on cost containment in Taiwan hospitals: the agency theory perspective.

    PubMed

    Chang, Li

    2011-01-01

    This study aims to determine whether the Taiwanese government's implementation of new health care payment reforms (the National Health Insurance with fee-for-service (NHI-FFS) and global budget (NHI-GB)) has resulted in better cost containment. Also, the question arises under the agency theory whether the monitoring system is effective in reducing the risk of information asymmetry. This study uses panel data analysis with fixed effects model to investigate changes in cost containment at Taipei municipal hospitals before and after adopting reforms from 1989 to 2004. The results show that the monitoring system does not reduce information asymmetry to improve cost containment under the NHI-FFS. In addition, after adopting the NHI-GB system, health care costs are controlled based on an improved monitoring system in the policymaker's point of view. This may suggest that the NHI's fee-for-services system actually causes health care resource waste. The GB may solve the problems of controlling health care costs only on the macro side.

  19. Performance Monitoring of Distributed Data Processing Systems

    NASA Technical Reports Server (NTRS)

    Ojha, Anand K.

    2000-01-01

    Test and checkout systems are essential components in ensuring safety and reliability of aircraft and related systems for space missions. A variety of systems, developed over several years, are in use at the NASA/KSC. Many of these systems are configured as distributed data processing systems with the functionality spread over several multiprocessor nodes interconnected through networks. To be cost-effective, a system should take the least amount of resource and perform a given testing task in the least amount of time. There are two aspects of performance evaluation: monitoring and benchmarking. While monitoring is valuable to system administrators in operating and maintaining, benchmarking is important in designing and upgrading computer-based systems. These two aspects of performance evaluation are the foci of this project. This paper first discusses various issues related to software, hardware, and hybrid performance monitoring as applicable to distributed systems, and specifically to the TCMS (Test Control and Monitoring System). Next, a comparison of several probing instructions are made to show that the hybrid monitoring technique developed by the NIST (National Institutes for Standards and Technology) is the least intrusive and takes only one-fourth of the time taken by software monitoring probes. In the rest of the paper, issues related to benchmarking a distributed system have been discussed and finally a prescription for developing a micro-benchmark for the TCMS has been provided.

  20. Performance monitoring algorithm for optimizing electrical power generated by using photovoltaic system

    NASA Astrophysics Data System (ADS)

    Pradeep, M. V. K.; Balbir, S. M. S.; Norani, M. M.

    2016-11-01

    Demand for electricity in Malaysia has seen a substantial hike in light of the nation's rapid economic development. The current method of generating electricity is through the combustion of fossil fuels which has led to the detrimental effects on the environment besides causing social and economic outbreaks due to its highly volatile prices. Thus the need for a sustainable energy source is paramount and one that is quickly gaining acceptance is solar energy. However, due to the various environmental and geographical factors that affect the generation of solar electricity, the capability of solar electricity generating system (SEGS) is unable to compete with the high conversion efficiencies of conventional energy sources. In order to effectively monitor SEGS, this study is proposing a performance monitoring system that is capable of detecting drops in the system's performance for parallel networks through a diagnostic mechanism. The performance monitoring system consists of microcontroller connected to relevant sensors for data acquisition. The acquired data is transferred to a microcomputer for software based monitoring and analysis. In order to enhance the interception of sunlight by the SEGS, a sensor based sun tracking system is interfaced to the same controller to allow the PV to maneuver itself autonomously to an angle of maximum sunlight exposure.

  1. Real-time alpha monitoring of a radioactive liquid waste stream at Los Alamos National Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, J.D.; Whitley, C.R.; Rawool-Sullivan, M.

    1995-12-31

    This poster display concerns the development, installation, and testing of a real-time radioactive liquid waste monitor at Los Alamos National Laboratory (LANL). The detector system was designed for the LANL Radioactive Liquid Waste Treatment Facility so that influent to the plant could be monitored in real time. By knowing the activity of the influent, plant operators can better monitor treatment, better segregate waste (potentially), and monitor the regulatory compliance of users of the LANL Radioactive Liquid Waste Collection System. The detector system uses long-range alpha detection technology, which is a nonintrusive method of characterization that determines alpha activity on themore » liquid surface by measuring the ionization of ambient air. Extensive testing has been performed to ensure long-term use with a minimal amount of maintenance. The final design was a simple cost-effective alpha monitor that could be modified for monitoring influent waste streams at various points in the LANL Radioactive Liquid Waste Collection System.« less

  2. Bed Bug (Hemiptera: Cimicidae) Detection in Low-Income, High-Rise Apartments Using Four or Fewer Passive Monitors.

    PubMed

    Vail, K M; Chandler, J G

    2017-06-01

    Bed bug, Cimex lectularius L., management in low-income, high-rise housing for the elderly and disabled can be difficult. Early detection is key to slowing their spread, and reducing management cost and time needed for control. To determine the minimum number of passive monitors needed to detect low-level bed bug infestations in this environment, we evaluated three monitors placed one, two, or four per apartment in a 3 by 3 experimental design. One sticky monitor, The Bedbug Detection System, and the two pitfall monitors, ClimbUp Insect Interceptors BG and BlackOut BedBug Detectors, were evaluated. Bed bugs were trapped by the ClimbUp Insect Interceptors BG and the BlackOut BedBug Detector in 88% and 79% of apartments, respectively, but only in 39% of the apartments monitored with The Bedbug Detection System. The Bedbug Detection System required significantly longer time to detect bed bugs than either the ClimbUp Insect Interceptor BG or the BlackOut BedBug Detector. With the less effective Bedbug Detection System data removed from analyses, detection rates ranged from 80 to 90%, with no significant differences among one, two, or four monitors per apartment. Results indicate it is especially important to include a bed placement when only placing a few monitors. Future work should compare the combination of cursory visual inspections with various monitor numbers and placements per apartment to determine the most efficient, cost-effective system that will be accepted and implemented in low-income housing. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  3. Operational Monitoring of Data Production at KNMI

    NASA Astrophysics Data System (ADS)

    van de Vegte, John; Kwidama, Anecita; van Moosel, Wim; Oosterhof, Rijk; de Wit de Wit, Ronny; Klein Ikkink, Henk Jan; Som de Cerff, Wim; Verhoef, Hans; Koutek, Michal; Duin, Frank; van der Neut, Ian; verhagen, Robert; Wollerich, Rene

    2016-04-01

    Within KNMI a new fully automated system for monitoring the KNMI operational data production systems is being developed: PRISMA (PRocessflow Infrastructure Surveillance and Monitoring Application). Currently the KNMI operational (24/7) production systems consist of over 60 applications, running on different hardware systems and platforms. They are interlinked for the production of numerous data products, which are delivered to internal and external customers. Traditionally these applications are individually monitored by different applications or not at all; complicating root cause and impact analysis. Also, the underlying hardware and network is monitored via an isolated application. Goal of the PRISMA system is to enable production chain monitoring, which enables root cause analysis (what is the root cause of the disruption) and impact analysis (what downstream products/customers will be effected). The PRISMA system will make it possible to reduce existing monitoring applications and provides one interface for monitoring the data production. For modeling and storing the state of the production chains a graph database is used. The model is automatically updated by the applications and systems which are to be monitored. The graph models enables root cause and impact analysis. In the PRISMA web interface interaction with the graph model is accomplished via a graphical representation. The presentation will focus on aspects of: • Modeling real world computers, applications, products to a conceptual model; • Architecture of the system; • Configuration information and (real world) event handling of the to be monitored objects; • Implementation rules for root cause and impact analysis. • How PRISMA was developed (methodology, facts, results) • Presentation of the PRISMA system as it now looks and works

  4. Identifying professionals' needs in integrating electronic pain monitoring in community palliative care services: An interview study.

    PubMed

    Taylor, Sally; Allsop, Matthew J; Bekker, Hilary L; Bennett, Michael I; Bewick, Bridgette M

    2017-07-01

    Poor pain assessment is a barrier to effective pain control. There is growing interest internationally in the development and implementation of remote monitoring technologies to enhance assessment in cancer and chronic disease contexts. Findings describe the development and testing of pain monitoring systems, but research identifying the needs of health professionals to implement routine monitoring systems within clinical practice is limited. To inform the development and implementation strategy of an electronic pain monitoring system, PainCheck, by understanding palliative care professionals' needs when integrating PainCheck into routine clinical practice. Qualitative study using face-to-face interviews. Data were analysed using framework analysis Setting/participants: Purposive sample of health professionals managing the palliative care of patients living in the community Results: A total of 15 interviews with health professionals took place. Three meta-themes emerged from the data: (1) uncertainties about integration of PainCheck and changes to current practice, (2) appraisal of current practice and (3) pain management is everybody's responsibility Conclusion: Even the most sceptical of health professionals could see the potential benefits of implementing an electronic patient-reported pain monitoring system. Health professionals have reservations about how PainCheck would work in practice. For optimal use, PainCheck needs embedding within existing electronic health records. Electronic pain monitoring systems have the potential to enable professionals to support patients' pain management more effectively but only when barriers to implementation are appropriately identified and addressed.

  5. Optical signal monitoring in phase modulated optical fiber transmission systems

    NASA Astrophysics Data System (ADS)

    Zhao, Jian

    Optical performance monitoring (OPM) is one of the essential functions for future high speed optical networks. Among the parameters to be monitored, chromatic dispersion (CD) is especially important since it has a significant impact on overall system performance. In this thesis effective CD monitoring approaches for phase-shift keying (PSK) based optical transmission systems are investigated. A number of monitoring schemes based on radio frequency (RF) spectrum analysis and delay-tap sampling are proposed and their performance evaluated. A method for dispersion monitoring of differential phase-shift keying (DPSK) signals based on RF power detection is studied. The RF power spectrum is found to increase with the increase of CD and decrease with polarization mode dispersion (PMD). The spectral power density dependence on CD is studied theoretically and then verified through simulations and experiments. The monitoring sensitivity for nonreturn-to-zero differential phase-shift keying (NRZ-DPSK) and return-to-zero differential phase-shift keying (RZ-DPSK) based systems can reach 80ps/nm/dB and 34ps/nm/dB respectively. The scheme enables the monitoring of differential group delay (DGD) and CD simultaneously. The monitoring sensitivity of CD and DGD can reach 56.7ps/nm/dB and 3.1ps/dB using a bandpass filter. The effects of optical signal-to-noise ratio (OSNR), DGD, fiber nonlinearity and chirp on the monitoring results are investigated. Two RF pilot tones are employed for CD monitoring of DPSK signals. Specially selected pilot tone frequencies enable good monitoring sensitivity with minimum influence on the received signals. The dynamic range exceeding 35dB and monitoring sensitivity up to 9.5ps/nm/dB are achieved. Asynchronous sampling technique is employed for CD monitoring. A signed CD monitoring method for 10Gb/s NRZ-DPSK and RZ-DPSK systems using asynchronous delay-tap sampling technique is studied. The demodulated signals suffer asymmetric waveform distortion if there is a phase error (Deltaphi) in the delay interferometer (DI) and in the presence of residual CD. Using delay-tap sampling the scatter plots can reflect this signal distortion through their asymmetric characteristics. A distance ratio (DR) is defined to represent the change of the scatter plots which is directly related to the accumulated CD. The monitoring range can be up to +/-400ps/nm and to +/-720ps/nm for 10Gb/s NRZ-DPSK and RZ-DPSK signals with 450 phase error in DI. The monitoring sensitivity reaches +/-8ps/nm and CD polarity discrimination is realized. It is found that the signal degradation is related to the increment of the absolute value of CD or phase mismatch. The effect of different polarities of phase error on CD monitoring is also analyzed. The shoulders location depends on the sign of the product DLDeltaphi. If DLDeltaphi > 0, the shoulder will appear on trailing edge else the shoulder will appear on leading edge when DLDeltaphi < 0. The analysis shows that the phase error is identical to the frequency offset of optical source so a signed frequency offset monitoring is also demonstrated. The monitoring results show that the monitoring range can reach +/-2.2GHz and the monitoring sensitivity is around 27MHz. The effect of nonlinearity, OSNR and bandwidth of the lowpass filter on the proposed monitoring method has also been studied. The signed CD monitoring for 100Gb/s carrier suppressed return-to-zero differential quadrature phase-shift keying (CSRZ-DQPSK) system based on the delay-tap sampling technology is demonstrated. The monitoring range and monitoring resolution can goes up to +/-32ps/nm and +/-8ps/nm, respectively. A signed CD and optical carrier wavelength monitoring scheme using cross-correlation method for on-off keying (00K) wavelength division multiplexing (WDM) system is proposed and demonstrated. CD monitoring sensitivity is high and can be less than 10% of the bit period. Wavelength monitoring is implemented using the proposed approach. The monitoring results show that the sensitivity can reach up to 1.37ps/GHz.

  6. The OA System of College - - Design of the Teaching Quality Monitoring Subsystem

    NASA Astrophysics Data System (ADS)

    Wu, Hongjuan; Ying, Hong; Jiang, Youyi; Yan, Pei

    According to the drawbacks of traditional teaching quality monitoring subsystems and based on the achievements of practical research in the teaching quality monitoring administration in College, this paper provides a design of overall structure of teaching quality monitoring subsystem, that is more suitable for colleges' management. This new system is endowed with the same features as .NET application programes: easy to extend, easy to maintain, flexible, convenient, and it let enterprises, students' parents and excellent graduates participate in teaching quality monitoring administration, have significant effect to ensure the quality of talent training in colleges.

  7. Hybrid wireless sensor network for rescue site monitoring after earthquake

    NASA Astrophysics Data System (ADS)

    Wang, Rui; Wang, Shuo; Tang, Chong; Zhao, Xiaoguang; Hu, Weijian; Tan, Min; Gao, Bowei

    2016-07-01

    This paper addresses the design of a low-cost, low-complexity, and rapidly deployable wireless sensor network (WSN) for rescue site monitoring after earthquakes. The system structure of the hybrid WSN is described. Specifically, the proposed hybrid WSN consists of two kinds of wireless nodes, i.e., the monitor node and the sensor node. Then the mechanism and the system configuration of the wireless nodes are detailed. A transmission control protocol (TCP)-based request-response scheme is proposed to allow several monitor nodes to communicate with the monitoring center. UDP-based image transmission algorithms with fast recovery have been developed to meet the requirements of in-time delivery of on-site monitor images. In addition, the monitor node contains a ZigBee module that used to communicate with the sensor nodes, which are designed with small dimensions to monitor the environment by sensing different physical properties in narrow spaces. By building a WSN using these wireless nodes, the monitoring center can display real-time monitor images of the monitoring area and visualize all collected sensor data on geographic information systems. In the end, field experiments were performed at the Training Base of Emergency Seismic Rescue Troops of China and the experimental results demonstrate the feasibility and effectiveness of the monitor system.

  8. Deep-brain stimulator and control of Parkinson's disease

    NASA Astrophysics Data System (ADS)

    Varadan, Vijay K.; Harbaugh, Robert; Abraham, Jose K.

    2004-07-01

    The design of a novel feedback sensor system with wireless implantable polymer MEMS sensors for detecting and wirelessly transmitting physiological data that can be used for the diagnosis and treatment of various neurological disorders, such as Parkinson's disease, epilepsy, head injury, stroke, hydrocephalus, changes in pressure, patient movements, and tremors is presented in this paper. The sensor system includes MEMS gyroscopes, accelerometers, and pressure sensors. This feedback sensor system focuses on the development and integration of implantable systems with various wireless sensors for medical applications, particularly for the Parkinson's disease. It is easy to integrate and modify the sensor network feed back system for other neurological disorders mentioned above. The monitoring and control of tremor in Parkinson's disease can be simulated on a skeleton via wireless telemetry system communicating with electroactive polymer actuator, and microsensors attached to the skeleton hand and legs. Upon sensing any abnormal motor activity which represent the characteristic rhythmic motion of a typical Parkinson's (PD) patient, these sensors will generate necessary control pulses which will be transmitted to a hat sensor system on the skeleton head. Tiny inductively coupled antennas attached to the hat sensor system can receive these control pulses, demodulate and deliver it to actuate the parts of the skeleton to control the abnormal motor activity. This feedback sensor system can further monitor and control depending on the amplitude of the abnormal motor activity. This microsystem offers cost effective means of monitoring and controlling of neurological disorders in real PD patients. Also, this network system offers a remote monitoring of the patients conditions without visiting doctors office or hospitals. The data can be monitored using PDA and can be accessed using internet (or cell phone). Cellular phone technology will allow a health care worker to be automatically notified if monitoring indicates an emergency situation. The main advantage of such system is that it can effectively monitor large number of patients at the same time, which helps to compensate the present shortage of health care workers.

  9. State of the art evaluation of traffic detection and monitoring systems. Volume 1, phases A & B : design [Summary

    DOT National Transportation Integrated Search

    2007-10-01

    Accurate, complete, and timely traffic data is critical to the effective management of Arizonas highway system. Limitations in current traffic monitoring abilities are an ongoing challenge for the Arizona Department of Transportation (ADOT) and fo...

  10. Campaign monitoring of railroad bridges in high-speed rail shared corridors using wireless smart sensors.

    DOT National Transportation Integrated Search

    2015-06-01

    This research project used wireless smart sensors to develop a cost-effective and practical portable structural health monitoring : system for railroad bridges in North America. The system is designed for periodic deployment rather than as a permanen...

  11. Coastwide Reference Monitoring System (CRMS)

    USGS Publications Warehouse

    2010-01-01

    In 1990, the U.S. Congress enacted the Coastal Wetlands Planning, Protection and Restoration Act (CWPPRA) in response to growing awareness of a land loss crisis in Louisiana. Projects funded by CWPPRA require monitoring and evaluation of project effectiveness, and there is also a need to assess the cumulative effects of all projects to achieve a sustainable coastal environment. In 2003, the Louisiana Office of Coastal Protection and Restoration (OCPR) and the U.S. Geological Survey (USGS) received approval from the CWPPRA Task Force to implement the Coastwide Reference Monitoring System (CRMS) as a mechanism to monitor and evaluate the effectiveness of CWPPRA projects at the project, region, and coastwide levels. The CRMS design implements a multiple reference approach by using aspects of hydrogeomorphic functional assessments and probabilistic sampling. The CRMS program is as dynamic as the coastal habitats it monitors. The program is currently funded through CWPPRA and provides data for a variety of user groups, including resource managers, academics, landowners, and researchers.

  12. Ecoregional-scale monitoring within conservation areas, in a rapidly changing climate

    USGS Publications Warehouse

    Beever, Erik A.; Woodward, Andrea

    2011-01-01

    Long-term monitoring of ecological systems can prove invaluable for resource management and conservation. Such monitoring can: (1) detect instances of long-term trend (either improvement or deterioration) in monitored resources, thus providing an early-warning indication of system change to resource managers; (2) inform management decisions and help assess the effects of management actions, as well as anthropogenic and natural disturbances; and (3) provide the grist for supplemental research on mechanisms of system dynamics and cause-effect relationships (Fancy et al., 2009). Such monitoring additionally provides a snapshot of the status of monitored resources during each sampling cycle, and helps assess whether legal standards and regulations are being met. Until the last 1-2 decades, tracking and understanding changes in condition of natural resources across broad spatial extents have been infrequently attempted. Several factors, however, are facilitating the achievement of such broad-scale investigation and monitoring. These include increasing awareness of the importance of landscape context, greater prevalence of regional and global environmental stressors, and the rise of landscape-scale programs designed to manage and monitor biological systems. Such programs include the US Forest Service's Forest Inventory and Analysis (FIA) Program (Moser et al., 2008), Canada's National Forest Inventory, the 3Q Programme for monitoring agricultural landscapes of Norway (Dramstad et al., 2002), and the emerging (US) Landscape Conservation Cooperatives (USDOI Secretarial Order 3289, 2009; Anonymous, 2011). This Special Section explores the underlying design considerations, as well as many pragmatic aspects associated with program implementation and interpretation of results from broad-scale monitoring systems, particularly within the constraints of high-latitude contexts (e.g., low road density, short field season, dramatic fluctuations in temperature). Although Alaska is the focus of most papers in this Special Section, we posit that many of the issues that characterize the remote, relatively undisturbed ecosystems of high northern latitudes are widespread and thus applicable to natural-resource management and conservation across northern portions of the Holarctic ecozone and indeed anywhere broad-scale monitoring is contemplated.

  13. An Advanced NSSS Integrity Monitoring System for Shin-Kori Nuclear Units 3 and 4

    NASA Astrophysics Data System (ADS)

    Oh, Yang Gyun; Galin, Scott R.; Lee, Sang Jeong

    2010-12-01

    The advanced design features of NSSS (Nuclear Steam Supply System) Integrity Monitoring System for Shin-Kori Nuclear Units 3 and 4 are summarized herein. During the overall system design and detailed component design processes, many design improvements have been made for the system. The major design changes are: 1) the application of a common software platform for all subsystems, 2) the implementation of remote access, control and monitoring capabilities, and 3) the equipment redesign and rearrangement that has simplified the system architecture. Changes give an effect on cabinet size, number of cables, cyber-security, graphic user interfaces, and interfaces with other monitoring systems. The system installation and operation for Shin-Kori Nuclear Units 3 and 4 will be more convenient than those for previous Korean nuclear units in view of its remote control capability, automated test functions, improved user interface functions, and much less cabling.

  14. A customized resistivity system for monitoring saturation and seepage in earthen levees: installation and validation

    NASA Astrophysics Data System (ADS)

    Arosio, Diego; Munda, Stefano; Tresoldi, Greta; Papini, Monica; Longoni, Laura; Zanzi, Luigi

    2017-10-01

    This work is based on the assumption that a resistivity meter can effectively monitor water saturation in earth levees and can be used as a warning system when saturation exceeds the expected seasonal maxima. We performed time-lapse ERT measurements to assess the capability of this method to detect areas where seepage is critical. These measurements were also very useful to design a prototype monitoring system with remarkable savings by customizing the specifications according to field observations. The prototype consists of a remotely controlled low-power resistivity meter with a spread of 48 stainless steel 20 × 20 cm plate electrodes buried at half-meter depth. We deployed the newly-designed permanent monitoring system on a critical levee segment. A weather station and an ultrasonic water level sensor were also installed in order to analyse the correlation of resistivity with temperature, rainfalls and water level seasonal variations. The preliminary analysis of the monitoring data shows that the resistivity maps follow a very reasonable trend related with the saturation/drying cycle of the levee caused by the seasonal variations of the water level in the irrigation channel. Sharp water level changes cause delayed and smooth resistivity variations. Rainfalls and, to a lesser extent, temperature seem to have an influence on the collected data but effects are apparently negligible beyond 1 m depth. The system is currently operating and results are continuously monitored.

  15. Research of diagnosis sensors fault based on correlation analysis of the bridge structural health monitoring system

    NASA Astrophysics Data System (ADS)

    Hu, Shunren; Chen, Weimin; Liu, Lin; Gao, Xiaoxia

    2010-03-01

    Bridge structural health monitoring system is a typical multi-sensor measurement system due to the multi-parameters of bridge structure collected from the monitoring sites on the river-spanning bridges. Bridge structure monitored by multi-sensors is an entity, when subjected to external action; there will be different performances to different bridge structure parameters. Therefore, the data acquired by each sensor should exist countless correlation relation. However, complexity of the correlation relation is decided by complexity of bridge structure. Traditionally correlation analysis among monitoring sites is mainly considered from physical locations. unfortunately, this method is so simple that it cannot describe the correlation in detail. The paper analyzes the correlation among the bridge monitoring sites according to the bridge structural data, defines the correlation of bridge monitoring sites and describes its several forms, then integrating the correlative theory of data mining and signal system to establish the correlation model to describe the correlation among the bridge monitoring sites quantificationally. Finally, The Chongqing Mashangxi Yangtze river bridge health measurement system is regards as research object to diagnosis sensors fault, and simulation results verify the effectiveness of the designed method and theoretical discussions.

  16. Remote Energy Monitoring System via Cellular Network

    NASA Astrophysics Data System (ADS)

    Yunoki, Shoji; Tamaki, Satoshi; Takada, May; Iwaki, Takashi

    Recently, improvement on power saving and cost efficiency by monitoring the operation status of various facilities over the network has gained attention. Wireless network, especially cellular network, has advantage in mobility, coverage, and scalability. On the other hand, it has disadvantage of low reliability, due to rapid changes in the available bandwidth. We propose a transmission control scheme based on data priority and instantaneous available bandwidth to realize a highly reliable remote monitoring system via cellular network. We have developed our proposed monitoring system and evaluated the effectiveness of our scheme, and proved it reduces the maximum transmission delay of sensor status to 1/10 compared to best effort transmission.

  17. Novel online monitoring and alert system for anaerobic digestion reactors.

    PubMed

    Dong, Fang; Zhao, Quan-Bao; Li, Wen-Wei; Sheng, Guo-Ping; Zhao, Jin-Bao; Tang, Yong; Yu, Han-Qing; Kubota, Kengo; Li, Yu-You; Harada, Hideki

    2011-10-15

    Effective monitoring and diagnosis of anaerobic digestion processes is a great challenge for anaerobic digestion reactors, which limits their stable operation. In this work, an online monitoring and alert system for upflow anaerobic sludge blanket (UASB) reactors is developed on the basis of a set of novel evaluating indexes. The two indexes, i.e., stability index S and auxiliary index a, which incorporate both gas- and liquid-phase parameters for UASB, enable a quantitative and comprehensive evaluation of reactor status. A series of shock tests is conducted to evaluate the response of the monitoring and alert system to organic overloading, hydraulic, temperature, and toxicant shocks. The results show that this system enables an accurate and rapid monitoring and diagnosis of the reactor status, and offers reliable early warnings on the potential risks. As the core of this system, the evaluating indexes are demonstrated to be of high accuracy and sensitivity in process evaluation and good adaptability to the artificial intelligence and automated control apparatus. This online monitoring and alert system presents a valuable effort to promote the automated monitoring and control of anaerobic digestion process, and holds a high promise for application.

  18. National Satellite Forest Monitoring systems for REDD+

    NASA Astrophysics Data System (ADS)

    Jonckheere, I. G.

    2012-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification, FAO supports the countries to develop national satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV) of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the support to UN-REDD pilot countries in this capacity building effort is the training of technical forest people and IT persons from interested REDD+ countries, and to set- up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows countries to adapt it to country needs and the training on the TerraAmazon system is a tool to enhance existing capacity on carbon monitoring systems. The support with the National Forest Monitoring System will allow these countries to follow all actions related to the implementation of its national REDD+ policies and measures. The monitoring system will work as a platform to obtain information on their REDD+ results and actions, related directly or indirectly to national REDD+ strategies and may also include actions unrelated to carbon assessment, such as forest law enforcement. With the technical assistance of FAO, INPE and other stakeholders, the countries will set up an autonomous operational forest monitoring system. An initial version and the methodologies of the system for DRC and PNG has been launched in Durban, South Africa during COP 17 and in 2012 Paraguay, Viet Nam and Zambia will be launched in Doha, Qatar at COP 18. The access to high-quality satellite data for these countries is crucial for the set-up.

  19. Shipborne LiDAR system for coastal change monitoring

    NASA Astrophysics Data System (ADS)

    Kim, chang hwan; Park, chang hong; Kim, hyun wook; hyuck Kim, won; Lee, myoung hoon; Park, hyeon yeong

    2016-04-01

    Coastal areas, used as human utilization areas like leisure space, medical care, ports and power plants, etc., are regions that are continuously changing and interconnected with oceans and land and the sea level has risen by about 8cm (1.9mm / yr) due to global warming from 1964 year to 2006 year in Korea. Coastal erosion due to sea-level rise has caused the problem of marine ecosystems and loss of tourism resources, etc. Regular monitoring of coastal erosion is essential at key locations with such volatility. But the survey method of land mobile LiDAR (light detection and ranging) system has much time consuming and many restrictions. For effective monitoring beach erosion, KIOST (Korea Institute of Ocean Science & Technology) has constructed a shipborne mobile LiDAR system. The shipborne mobile LiDAR system comprised a land mobile LiDAR (RIEGL LMS-420i), an INS (inertial navigation system, MAGUS Inertial+), a RTKGPS (LEICA GS15 GS25), and a fixed platform. The shipborne mobile LiDAR system is much more effective than a land mobile LiDAR system in the measuring of fore shore areas without shadow zone. Because the vessel with the shipborne mobile LiDAR system is continuously moved along the shoreline, it is possible to efficiently survey a large area in a relatively short time. Effective monitoring of the changes using the constructed shipborne mobile LiDAR system for seriously eroded coastal areas will be able to contribute to coastal erosion management and response.

  20. An overview: modern techniques for railway vehicle on-board health monitoring systems

    NASA Astrophysics Data System (ADS)

    Li, Chunsheng; Luo, Shihui; Cole, Colin; Spiryagin, Maksym

    2017-07-01

    Health monitoring systems with low-cost sensor networks and smart algorithms are always needed in both passenger trains and heavy haul trains due to the increasing need for reliability and safety in the railway industry. This paper focuses on an overview of existing approaches applied for railway vehicle on-board health monitoring systems. The approaches applied in the data measurement systems and the data analysis systems in railway on-board health monitoring systems are presented in this paper, including methodologies, theories and applications. The pros and cons of the various approaches are analysed to determine appropriate benchmarks for an effective and efficient railway vehicle on-board health monitoring system. According to this review, inertial sensors are the most popular due to their advantages of low cost, robustness and low power consumption. Linearisation methods are required for the model-based methods which would inevitably introduce error to the estimation results, and it is time-consuming to include all possible conditions in the pre-built database required for signal-based methods. Based on this review, future development trends in the design of new low-cost health monitoring systems for railway vehicles are discussed.

  1. 29 CFR 1910.1017 - Vinyl chloride.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...: Cancer; central nervous system effects; liver effects; blood effects; and flammability. (iii) Employers..., whichever occurs first. (B) A continuous-monitoring and alarm system must be provided when concentrations of... system must be used to alert employees when vinyl chloride concentrations exceed the allowable...

  2. 29 CFR 1910.1017 - Vinyl chloride.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...: Cancer; central nervous system effects; liver effects; blood effects; and flammability. (iii) Employers..., whichever occurs first. (B) A continuous-monitoring and alarm system must be provided when concentrations of... system must be used to alert employees when vinyl chloride concentrations exceed the allowable...

  3. 29 CFR 1910.1017 - Vinyl chloride.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...: Cancer; central nervous system effects; liver effects; blood effects; and flammability. (iii) Employers..., whichever occurs first. (B) A continuous-monitoring and alarm system must be provided when concentrations of... system must be used to alert employees when vinyl chloride concentrations exceed the allowable...

  4. Acoustic Flow Monitor System - User Manual

    USGS Publications Warehouse

    LaHusen, Richard

    2005-01-01

    INTRODUCTION The Acoustic Flow Monitor (AFM) is a portable system that was designed by the U.S. Geological Survey Cascades Volcano Observatory to detect and monitor debris flows associated with volcanoes. It has been successfully used internationally as part of real-time warning systems in valleys threatened by such flows (Brantley, 1990; Marcial and others, 1996; Lavigne and others, 2000). The AFM system has also been proven to be an effective tool for monitoring some non-volcanic debris flows. This manual is intended to serve as a basic guide for the installation, testing, and maintenance of AFM systems. An overview of how the system works, as well as instructions for installation and guidelines for testing, is included. Interpretation of data is not covered in this manual; rather, the user should refer to the references provided for published examples of AFM data.

  5. Vehicle Counting and Moving Direction Identification Based on Small-Aperture Microphone Array.

    PubMed

    Zu, Xingshui; Zhang, Shaojie; Guo, Feng; Zhao, Qin; Zhang, Xin; You, Xing; Liu, Huawei; Li, Baoqing; Yuan, Xiaobing

    2017-05-10

    The varying trend of a moving vehicle's angles provides much important intelligence for an unattended ground sensor (UGS) monitoring system. The present study investigates the capabilities of a small-aperture microphone array (SAMA) based system to identify the number and moving direction of vehicles travelling on a previously established route. In this paper, a SAMA-based acoustic monitoring system, including the system hardware architecture and algorithm mechanism, is designed as a single node sensor for the application of UGS. The algorithm is built on the varying trend of a vehicle's bearing angles around the closest point of approach (CPA). We demonstrate the effectiveness of our proposed method with our designed SAMA-based monitoring system in various experimental sites. The experimental results in harsh conditions validate the usefulness of our proposed UGS monitoring system.

  6. Use of Continuous Integration Tools for Application Performance Monitoring

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vergara Larrea, Veronica G; Joubert, Wayne; Fuson, Christopher B

    High performance computing systems are becom- ing increasingly complex, both in node architecture and in the multiple layers of software stack required to compile and run applications. As a consequence, the likelihood is increasing for application performance regressions to occur as a result of routine upgrades of system software components which interact in complex ways. The purpose of this study is to evaluate the effectiveness of continuous integration tools for application performance monitoring on HPC systems. In addition, this paper also describes a prototype system for application perfor- mance monitoring based on Jenkins, a Java-based continuous integration tool. The monitoringmore » system described leverages several features in Jenkins to track application performance results over time. Preliminary results and lessons learned from monitoring applications on Cray systems at the Oak Ridge Leadership Computing Facility are presented.« less

  7. Guidebook for development of traffic monitoring systems for major traffic generators in the state of Texas.

    DOT National Transportation Integrated Search

    2009-09-01

    The purpose of this guide is to aid the Texas Department of Transportation (TxDOT), Metropolitan Planning Organizations (MPO), and other state and local agencies to develop an effective traffic monitoring system for new major traffic generators in th...

  8. Environmental, political, and economic determinants of water quality monitoring in Europe

    NASA Astrophysics Data System (ADS)

    Beck, Lucas; Bernauer, Thomas; Kalbhenn, Anna

    2010-11-01

    Effective monitoring is essential for effective pollution control in national and international water systems. To what extent are countries' monitoring choices driven by environmental criteria, as they should be? And to what extent are they also influenced by other factors, such as political and economic conditions? To address these questions, we describe and explain the evolution of one of the most important international environmental monitoring networks in Europe, the one for water quality, in the time period 1965-2004. We develop a geographic information system that contains information on the location of several thousand active monitoring stations in Europe. Using multivariate statistics, we then examine whether and to what extent the spatial and temporal clustering of monitoring intensity is driven by environmental, political, and economic factors. The results show that monitoring intensity is higher in river basins exposed to greater environmental pressure. However, political and economic factors also play a strong role in monitoring decisions: democracy, income, and peer pressure are conducive to monitoring intensity, and monitoring intensity generally increases over time. Moreover, even though monitoring is more intense in international upstream-downstream settings, we observe only a weak bias toward more monitoring downstream of international borders. In contrast, negative effects of European Union (EU) membership and runup to the EU's Water Framework Directive are potential reasons for concern. Our results strongly suggest that international coordination and standardization of water quality monitoring should be intensified. It will be interesting to apply our analytical approach also to other national and international monitoring networks, for instance, the U.S. National Water-Quality Assessment Program or the European Monitoring and Evaluation Program for air pollution.

  9. Monitoring of human populations for early markers of cadmium toxicity: A review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fowler, Bruce A.

    2009-08-01

    Exposure of human populations to cadmium (Cd) from air, food and water may produce effects in organs such as the kidneys, liver, lungs, cardiovascular, immune and reproductive systems. Since Cd has been identified as a human carcinogen, biomarkers for early detection of susceptibility to cancer are of an importance to public health. The ability to document Cd exposure and uptake of this element through biological monitoring is a first step towards understanding its health effects. Interpretation and application of biological monitoring data for predicting human health outcomes require correlation with biological measures of organ system responses to the documented exposure.more » Essential to this understanding is the detection and linkage of early biological responses toxic effects in target cell populations. Fortunately, advances in cell biology have resulted in the development of pre-clinical biological markers (biomarkers) that demonstrate measurable and characteristic molecular changes in organ systems following chemical exposures that occur prior to the onset of overt clinical disease or development of cancer. Technical advances have rendered a number of these biomarkers practical for monitoring Cd-exposed human populations. Biomarkers will be increasingly important in relation to monitoring effects from the exposure to new Cd-based high technology materials. For example, cadmium-selenium (CdSe), nano-materials made from combinations of these elements have greatly altered cellular uptake characteristics due to particle size. These differences may greatly alter effects at the target cell level and hence risks for organ toxicities from such exposures. The value of validated biomarkers for early detection of systemic Cd-induced effects in humans cannot be underestimated due to the rapid expansion of nano-material technologies. This review will attempt to briefly summarize the applications, to date, of biomarker endpoints for assessing target organ system effects in humans and experimental systems from Cd exposure. Further, it will attempt to provide a prospective look at the possible future of biomarkers. The emphasis will be on the detection of early toxic effects from exposure to Cd in new products such as nano-materials and identification of populations at special risk for Cd toxicity.« less

  10. Monitoring of human populations for early markers of cadmium toxicity: a review.

    PubMed

    Fowler, Bruce A

    2009-08-01

    Exposure of human populations to cadmium (Cd) from air, food and water may produce effects in organs such as the kidneys, liver, lungs, cardiovascular, immune and reproductive systems. Since Cd has been identified as a human carcinogen, biomarkers for early detection of susceptibility to cancer are of an importance to public health. The ability to document Cd exposure and uptake of this element through biological monitoring is a first step towards understanding its health effects. Interpretation and application of biological monitoring data for predicting human health outcomes require correlation with biological measures of organ system responses to the documented exposure. Essential to this understanding is the detection and linkage of early biological responses toxic effects in target cell populations. Fortunately, advances in cell biology have resulted in the development of pre-clinical biological markers (biomarkers) that demonstrate measurable and characteristic molecular changes in organ systems following chemical exposures that occur prior to the onset of overt clinical disease or development of cancer. Technical advances have rendered a number of these biomarkers practical for monitoring Cd-exposed human populations. Biomarkers will be increasingly important in relation to monitoring effects from the exposure to new Cd-based high technology materials. For example, cadmium-selenium (CdSe), nano-materials made from combinations of these elements have greatly altered cellular uptake characteristics due to particle size. These differences may greatly alter effects at the target cell level and hence risks for organ toxicities from such exposures. The value of validated biomarkers for early detection of systemic Cd-induced effects in humans cannot be underestimated due to the rapid expansion of nano-material technologies. This review will attempt to briefly summarize the applications, to date, of biomarker endpoints for assessing target organ system effects in humans and experimental systems from Cd exposure. Further, it will attempt to provide a prospective look at the possible future of biomarkers. The emphasis will be on the detection of early toxic effects from exposure to Cd in new products such as nano-materials and identification of populations at special risk for Cd toxicity.

  11. INDUCTIVE SYSTEM HEALTH MONITORING WITH STATISTICAL METRICS

    NASA Technical Reports Server (NTRS)

    Iverson, David L.

    2005-01-01

    Model-based reasoning is a powerful method for performing system monitoring and diagnosis. Building models for model-based reasoning is often a difficult and time consuming process. The Inductive Monitoring System (IMS) software was developed to provide a technique to automatically produce health monitoring knowledge bases for systems that are either difficult to model (simulate) with a computer or which require computer models that are too complex to use for real time monitoring. IMS processes nominal data sets collected either directly from the system or from simulations to build a knowledge base that can be used to detect anomalous behavior in the system. Machine learning and data mining techniques are used to characterize typical system behavior by extracting general classes of nominal data from archived data sets. In particular, a clustering algorithm forms groups of nominal values for sets of related parameters. This establishes constraints on those parameter values that should hold during nominal operation. During monitoring, IMS provides a statistically weighted measure of the deviation of current system behavior from the established normal baseline. If the deviation increases beyond the expected level, an anomaly is suspected, prompting further investigation by an operator or automated system. IMS has shown potential to be an effective, low cost technique to produce system monitoring capability for a variety of applications. We describe the training and system health monitoring techniques of IMS. We also present the application of IMS to a data set from the Space Shuttle Columbia STS-107 flight. IMS was able to detect an anomaly in the launch telemetry shortly after a foam impact damaged Columbia's thermal protection system.

  12. The clinical effectiveness and cost-effectiveness of point-of-care tests (CoaguChek system, INRatio2 PT/INR monitor and ProTime Microcoagulation system) for the self-monitoring of the coagulation status of people receiving long-term vitamin K antagonist therapy, compared with standard UK practice: systematic review and economic evaluation.

    PubMed

    Sharma, Pawana; Scotland, Graham; Cruickshank, Moira; Tassie, Emma; Fraser, Cynthia; Burton, Chris; Croal, Bernard; Ramsay, Craig R; Brazzelli, Miriam

    2015-06-01

    Self-monitoring (self-testing and self-management) could be a valid option for oral anticoagulation therapy monitoring in the NHS, but current evidence on its clinical effectiveness or cost-effectiveness is limited. We investigated the clinical effectiveness and cost-effectiveness of point-of-care coagulometers for the self-monitoring of coagulation status in people receiving long-term vitamin K antagonist therapy, compared with standard clinic monitoring. We searched major electronic databases (e.g. MEDLINE, MEDLINE In Process & Other Non-Indexed Citations, EMBASE, Bioscience Information Service, Science Citation Index and Cochrane Central Register of Controlled Trials) from 2007 to May 2013. Reports published before 2007 were identified from the existing Cochrane review (major databases searched from inception to 2007). The economic model parameters were derived from the clinical effectiveness review, other relevant reviews, routine sources of cost data and clinical experts' advice. We assessed randomised controlled trials (RCTs) evaluating self-monitoring in people with atrial fibrillation or heart valve disease requiring long-term anticoagulation therapy. CoaguChek(®) XS and S models (Roche Diagnostics, Basel, Switzerland), INRatio2(®) PT/INR monitor (Alere Inc., San Diego, CA USA), and ProTime Microcoagulation system(®) (International Technidyne Corporation, Nexus Dx, Edison, NJ, USA) coagulometers were compared with standard monitoring. Where possible, we combined data from included trials using standard inverse variance methods. Risk of bias assessment was performed using the Cochrane risk of bias tool. A de novo economic model was developed to assess the cost-effectiveness over a 10-year period. We identified 26 RCTs (published in 45 papers) with a total of 8763 participants. CoaguChek was used in 85% of the trials. Primary analyses were based on data from 21 out of 26 trials. Only four trials were at low risk of bias. Major clinical events: self-monitoring was significantly better than standard monitoring in preventing thromboembolic events [relative risk (RR) 0.58, 95% confidence interval (CI) 0.40 to 0.84; p = 0.004]. In people with artificial heart valves (AHVs), self-monitoring almost halved the risk of thromboembolic events (RR 0.56, 95% CI 0.38 to 0.82; p = 0.003) and all-cause mortality (RR 0.54, 95% CI 0.32 to 0.92; p = 0.02). There was greater reduction in thromboembolic events and all-cause mortality through self-management but not through self-testing. Intermediate outcomes: self-testing, but not self-management, showed a modest but significantly higher percentage of time in therapeutic range, compared with standard care (weighted mean difference 4.44, 95% CI 1.71 to 7.18; p = 0.02). Patient-reported outcomes: improvements in patients' quality of life related to self-monitoring were observed in six out of nine trials. High preference rates were reported for self-monitoring (77% to 98% in four trials). Net health and social care costs over 10 years were £7295 (self-monitoring with INRatio2); £7324 (standard care monitoring); £7333 (self-monitoring with CoaguChek XS) and £8609 (self-monitoring with ProTime). The estimated quality-adjusted life-year (QALY) gain associated with self-monitoring was 0.03. Self-monitoring with INRatio2 or CoaguChek XS was found to have ≈ 80% chance of being cost-effective, compared with standard monitoring at a willingness-to-pay threshold of £20,000 per QALY gained. Compared with standard monitoring, self-monitoring appears to be safe and effective, especially for people with AHVs. Self-monitoring, and in particular self-management, of anticoagulation status appeared cost-effective when pooled estimates of clinical effectiveness were applied. However, if self-monitoring does not result in significant reductions in thromboembolic events, it is unlikely to be cost-effective, based on a comparison of annual monitoring costs alone. Trials investigating the longer-term outcomes of self-management are needed, as well as direct comparisons of the various point-of-care coagulometers. This study is registered as PROSPERO CRD42013004944. The National Institute for Health Research Health Technology Assessment programme.

  13. Sericin/Dextran Injectable Hydrogel as an Optically Trackable Drug Delivery System for Malignant Melanoma Treatment.

    PubMed

    Liu, Jia; Qi, Chao; Tao, Kaixiong; Zhang, Jinxiang; Zhang, Jian; Xu, Luming; Jiang, Xulin; Zhang, Yunti; Huang, Lei; Li, Qilin; Xie, Hongjian; Gao, Jinbo; Shuai, Xiaoming; Wang, Guobin; Wang, Zheng; Wang, Lin

    2016-03-01

    Severe side effects of cancer chemotherapy prompt developing better drug delivery systems. Injectable hydrogels are an effective site-target system. For most of injectable hydrogels, once delivered in vivo, some properties including drug release and degradation, which are critical to chemotherapeutic effects and safety, are challenging to monitor. Developing a drug delivery system for effective cancer therapy with in vivo real-time noninvasive trackability is highly desired. Although fluorescence dyes are used for imaging hydrogels, the cytotoxicity limits their applications. By using sericin, a natural photoluminescent protein from silk, we successfully synthesized a hydrazone cross-linked sericin/dextran injectable hydrogel. This hydrogel is biodegradable and biocompatible. It achieves efficient drug loading and controlled release of both macromolecular and small molecular drugs. Notably, sericin's photoluminescence from this hydrogel is directly and stably correlated with its degradation, enabling long-term in vivo imaging and real-time monitoring of the remaining drug. The hydrogel loaded with Doxorubicin significantly suppresses tumor growth. Together, the work demonstrates the efficacy of this drug delivery system, and the in vivo effectiveness of this sericin-based optical monitoring strategy, providing a potential approach for improving hydrogel design toward optimal efficiency and safety of chemotherapies, which may be widely applicable to other drug delivery systems.

  14. An Embedded Wireless Sensor Network with Wireless Power Transmission Capability for the Structural Health Monitoring of Reinforced Concrete Structures

    PubMed Central

    Gallucci, Luca; Menna, Costantino; Angrisani, Leopoldo; Asprone, Domenico

    2017-01-01

    Maintenance strategies based on structural health monitoring can provide effective support in the optimization of scheduled repair of existing structures, thus enabling their lifetime to be extended. With specific regard to reinforced concrete (RC) structures, the state of the art seems to still be lacking an efficient and cost-effective technique capable of monitoring material properties continuously over the lifetime of a structure. Current solutions can typically only measure the required mechanical variables in an indirect, but economic, manner, or directly, but expensively. Moreover, most of the proposed solutions can only be implemented by means of manual activation, making the monitoring very inefficient and then poorly supported. This paper proposes a structural health monitoring system based on a wireless sensor network (WSN) that enables the automatic monitoring of a complete structure. The network includes wireless distributed sensors embedded in the structure itself, and follows the monitoring-based maintenance (MBM) approach, with its ABCDE paradigm, namely: accuracy, benefit, compactness, durability, and easiness of operations. The system is structured in a node level and has a network architecture that enables all the node data to converge in a central unit. Human control is completely unnecessary until the periodic evaluation of the collected data. Several tests are conducted in order to characterize the system from a metrological point of view and assess its performance and effectiveness in real RC conditions. PMID:29112128

  15. A Four Channel Beam Current Monitor Data Acquisition System Using Embedded Processors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wheat, Jr., Robert Mitchell; Dalmas, Dale A.; Dale, Gregory E.

    2015-08-11

    Data acquisition from multiple beam current monitors is required for electron accelerator production of Mo-99. A two channel system capable of recording data from two beam current monitors has been developed, is currently in use, and is discussed below. The development of a cost-effective method of extending this system to more than two channels and integrating of these measurements into an accelerator control system is the main focus of this report. Data from these current monitors is digitized, processed, and stored by a digital data acquisition system. Limitations and drawbacks with the currently deployed digital data acquisition system have beenmore » identified as have been potential solutions, or at least improvements, to these problems. This report will discuss and document the efforts we've made in improving the flexibility and lowering the cost of the data acquisition system while maintaining the minimum requirements.« less

  16. The Role of Satellite Data for the National Forest Monitoring Systems in the Context of REDD+

    NASA Astrophysics Data System (ADS)

    Jonckheere, Inge

    2012-04-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. “REDD+” goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme assists developing countries to prepare and implement national REDD+ strategies. For the monitoring, reporting and verification (MRV), FAO supports the countries to develop national forest monitoring systems (NFMS) based on satellite data that allow for credible MRV of REDD+ activities through time. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost- effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a multi-user basis, allows countries to adapt it to country needs. With the technical assistance of FAO, INPE and other stakeholders, the countries will set up an autonomous operational satellite forest monitoring systems. A beta version and the methodologies of the system for DRC and PNG are launched in Durban (SA) during COP 17, while Paraguay, Zambia and Viet Nam are in development in 2012.

  17. Tolerant indirect reciprocity can boost social welfare through solidarity with unconditional cooperators in private monitoring.

    PubMed

    Okada, Isamu; Sasaki, Tatsuya; Nakai, Yutaka

    2017-08-29

    Indirect reciprocity is an important mechanism for resolving social dilemmas. Previous studies explore several types of assessment rules that are evolutionarily stable for keeping cooperation regimes. However, little is known about the effects of private information on social systems. Most indirect reciprocity studies assume public monitoring in which individuals share a single assessment for each individual. Here, we consider a private monitoring system that loosens such an unnatural assumption. We explore the stable norms in the private system using an individual-based simulation. We have three main findings. First, narrow and unstable cooperation: cooperation in private monitoring becomes unstable and the restricted norms cannot maintain cooperative regimes while they can in public monitoring. Second, stable coexistence of discriminators and unconditional cooperators: under private monitoring, unconditional cooperation can play a role in keeping a high level of cooperation in tolerant norm situations. Finally, Pareto improvement: private monitoring can achieve a higher cooperation rate than does public monitoring.

  18. The applicability of animal health surveillance systems for post-market monitoring of potential adverse effects of genetically modified (GM) feed.

    PubMed

    Vince, L; Kleter, G A; Kostov, K; Pfeiffer, D U; Guitian, J

    2018-04-20

    A facultative post market monitoring of potential health impacts of genetically modified (GM) feedstuffs on livestock consuming these feeds after pre-market risk assessment is under ongoing consideration. Within the IPAFEED database, scientific studies on health effects beyond performance in livestock and the results of a systematic search for evidence of outcome effects due to GM feed are consolidated. These outcomes were reviewed and checked for consistency in order to identify plausible syndromes suitable for conducting surveillance. The 24 selected studies showed no consistent changes in any health parameter. There were no repeated studies in any species by GM crop type and animal species. As such, there is insufficient evidence to inform the design of surveillance systems for detecting known adverse effects. Animal health surveillance systems have been proposed for the post market monitoring of potential adverse effects in animals. Such systems were evaluated for their applicability to the detection of hypothetical adverse effects and their strengths and weaknesses to detect syndromes of concern are presented. For known adverse effects, applied controlled post-market studies may yield conclusive and high-quality evidence. For detecting unknown adverse effects, the use of existing surveillance systems may still be of interest. A simulation tool developed within the project can be adapted and applied to existing surveillance systems to explore their applicability to the detection of potential adverse effects of GM feed. Copyright © 2018. Published by Elsevier Ltd.

  19. An efficient management system for wireless sensor networks.

    PubMed

    Ma, Yi-Wei; Chen, Jiann-Liang; Huang, Yueh-Min; Lee, Mei-Yu

    2010-01-01

    Wireless sensor networks have garnered considerable attention recently. Networks typically have many sensor nodes, and are used in commercial, medical, scientific, and military applications for sensing and monitoring the physical world. Many researchers have attempted to improve wireless sensor network management efficiency. A Simple Network Management Protocol (SNMP)-based sensor network management system was developed that is a convenient and effective way for managers to monitor and control sensor network operations. This paper proposes a novel WSNManagement system that can show the connections stated of relationships among sensor nodes and can be used for monitoring, collecting, and analyzing information obtained by wireless sensor networks. The proposed network management system uses collected information for system configuration. The function of performance analysis facilitates convenient management of sensors. Experimental results show that the proposed method enhances the alive rate of an overall sensor node system, reduces the packet lost rate by roughly 5%, and reduces delay time by roughly 0.2 seconds. Performance analysis demonstrates that the proposed system is effective for wireless sensor network management.

  20. MACRO: a combined microchip-PCR and microarray system for high-throughput monitoring of genetically modified organisms.

    PubMed

    Shao, Ning; Jiang, Shi-Meng; Zhang, Miao; Wang, Jing; Guo, Shu-Juan; Li, Yang; Jiang, He-Wei; Liu, Cheng-Xi; Zhang, Da-Bing; Yang, Li-Tao; Tao, Sheng-Ce

    2014-01-21

    The monitoring of genetically modified organisms (GMOs) is a primary step of GMO regulation. However, there is presently a lack of effective and high-throughput methodologies for specifically and sensitively monitoring most of the commercialized GMOs. Herein, we developed a multiplex amplification on a chip with readout on an oligo microarray (MACRO) system specifically for convenient GMO monitoring. This system is composed of a microchip for multiplex amplification and an oligo microarray for the readout of multiple amplicons, containing a total of 91 targets (18 universal elements, 20 exogenous genes, 45 events, and 8 endogenous reference genes) that covers 97.1% of all GM events that have been commercialized up to 2012. We demonstrate that the specificity of MACRO is ~100%, with a limit of detection (LOD) that is suitable for real-world applications. Moreover, the results obtained of simulated complex samples and blind samples with MACRO were 100% consistent with expectations and the results of independently performed real-time PCRs, respectively. Thus, we believe MACRO is the first system that can be applied for effectively monitoring the majority of the commercialized GMOs in a single test.

  1. Wearable Sensors for Remote Health Monitoring.

    PubMed

    Majumder, Sumit; Mondal, Tapas; Deen, M Jamal

    2017-01-12

    Life expectancy in most countries has been increasing continually over the several few decades thanks to significant improvements in medicine, public health, as well as personal and environmental hygiene. However, increased life expectancy combined with falling birth rates are expected to engender a large aging demographic in the near future that would impose significant  burdens on the socio-economic structure of these countries. Therefore, it is essential to develop cost-effective, easy-to-use systems for the sake of elderly healthcare and well-being. Remote health monitoring, based on non-invasive and wearable sensors, actuators and modern communication and information technologies offers an efficient and cost-effective solution that allows the elderly to continue to live in their comfortable home environment instead of expensive healthcare facilities. These systems will also allow healthcare personnel to monitor important physiological signs of their patients in real time, assess health conditions and provide feedback from distant facilities. In this paper, we have presented and compared several low-cost and non-invasive health and activity monitoring systems that were reported in recent years. A survey on textile-based sensors that can potentially be used in wearable systems is also presented. Finally, compatibility of several communication technologies as well as future perspectives and research challenges in remote monitoring systems will be discussed.

  2. Wearable Sensors for Remote Health Monitoring

    PubMed Central

    Majumder, Sumit; Mondal, Tapas; Deen, M. Jamal

    2017-01-01

    Life expectancy in most countries has been increasing continually over the several few decades thanks to significant improvements in medicine, public health, as well as personal and environmental hygiene. However, increased life expectancy combined with falling birth rates are expected to engender a large aging demographic in the near future that would impose significant  burdens on the socio-economic structure of these countries. Therefore, it is essential to develop cost-effective, easy-to-use systems for the sake of elderly healthcare and well-being. Remote health monitoring, based on non-invasive and wearable sensors, actuators and modern communication and information technologies offers an efficient and cost-effective solution that allows the elderly to continue to live in their comfortable home environment instead of expensive healthcare facilities. These systems will also allow healthcare personnel to monitor important physiological signs of their patients in real time, assess health conditions and provide feedback from distant facilities. In this paper, we have presented and compared several low-cost and non-invasive health and activity monitoring systems that were reported in recent years. A survey on textile-based sensors that can potentially be used in wearable systems is also presented. Finally, compatibility of several communication technologies as well as future perspectives and research challenges in remote monitoring systems will be discussed. PMID:28085085

  3. Development of a Cost-Effective Airborne Remote Sensing System for Coastal Monitoring

    PubMed Central

    Kim, Duk-jin; Jung, Jungkyo; Kang, Ki-mook; Kim, Seung Hee; Xu, Zhen; Hensley, Scott; Swan, Aaron; Duersch, Michael

    2015-01-01

    Coastal lands and nearshore marine areas are productive and rapidly changing places. However, these areas face many environmental challenges related to climate change and human-induced impacts. Space-borne remote sensing systems may be restricted in monitoring these areas because of their spatial and temporal resolutions. In situ measurements are also constrained from accessing the area and obtaining wide-coverage data. In these respects, airborne remote sensing sensors could be the most appropriate tools for monitoring these coastal areas. In this study, a cost-effective airborne remote sensing system with synthetic aperture radar and thermal infrared sensors was implemented to survey coastal areas. Calibration techniques and geophysical model algorithms were developed for the airborne system to observe the topography of intertidal flats, coastal sea surface current, sea surface temperature, and submarine groundwater discharge. PMID:26437413

  4. Development of a Cost-Effective Airborne Remote Sensing System for Coastal Monitoring.

    PubMed

    Kim, Duk-jin; Jung, Jungkyo; Kang, Ki-mook; Kim, Seung Hee; Xu, Zhen; Hensley, Scott; Swan, Aaron; Duersch, Michael

    2015-09-30

    Coastal lands and nearshore marine areas are productive and rapidly changing places. However, these areas face many environmental challenges related to climate change and human-induced impacts. Space-borne remote sensing systems may be restricted in monitoring these areas because of their spatial and temporal resolutions. In situ measurements are also constrained from accessing the area and obtaining wide-coverage data. In these respects, airborne remote sensing sensors could be the most appropriate tools for monitoring these coastal areas. In this study, a cost-effective airborne remote sensing system with synthetic aperture radar and thermal infrared sensors was implemented to survey coastal areas. Calibration techniques and geophysical model algorithms were developed for the airborne system to observe the topography of intertidal flats, coastal sea surface current, sea surface temperature, and submarine groundwater discharge.

  5. A Cyber-Physical System for Girder Hoisting Monitoring Based on Smartphones.

    PubMed

    Han, Ruicong; Zhao, Xuefeng; Yu, Yan; Guan, Quanhua; Hu, Weitong; Li, Mingchu

    2016-07-07

    Offshore design and construction is much more difficult than land-based design and construction, particularly due to hoisting operations. Real-time monitoring of the orientation and movement of a hoisted structure is thus required for operators' safety. In recent years, rapid development of the smart-phone commercial market has offered the possibility that everyone can carry a mini personal computer that is integrated with sensors, an operating system and communication system that can act as an effective aid for cyber-physical systems (CPS) research. In this paper, a CPS for hoisting monitoring using smartphones was proposed, including a phone collector, a controller and a server. This system uses smartphones equipped with internal sensors to obtain girder movement information, which will be uploaded to a server, then returned to controller users. An alarming system will be provided on the controller phone once the returned data exceeds a threshold. The proposed monitoring system is used to monitor the movement and orientation of a girder during hoisting on a cross-sea bridge in real time. The results show the convenience and feasibility of the proposed system.

  6. 40 CFR 257.25 - Assessment monitoring program.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Minimum distance between upgradient edge of the unit and downgradient monitoring well screen (minimum... that is likely to be without appreciable risk of deleterious effects during a lifetime. For purposes of this subpart, systemic toxicants include toxic chemicals that cause effects other than cancer or...

  7. 40 CFR 257.25 - Assessment monitoring program.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Minimum distance between upgradient edge of the unit and downgradient monitoring well screen (minimum... that is likely to be without appreciable risk of deleterious effects during a lifetime. For purposes of this subpart, systemic toxicants include toxic chemicals that cause effects other than cancer or...

  8. 40 CFR 257.25 - Assessment monitoring program.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Minimum distance between upgradient edge of the unit and downgradient monitoring well screen (minimum... that is likely to be without appreciable risk of deleterious effects during a lifetime. For purposes of this subpart, systemic toxicants include toxic chemicals that cause effects other than cancer or...

  9. 40 CFR 258.55 - Assessment monitoring program.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... upgradient edge of the MSWLF unit and downgradient monitoring well screen (minimum distance of travel); (5... effects during a lifetime. For purposes of this subpart, systemic toxicants include toxic chemicals that cause effects other than cancer or mutation. (ii) [Reserved] (j) In establishing ground-water protection...

  10. 40 CFR 258.55 - Assessment monitoring program.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... upgradient edge of the MSWLF unit and downgradient monitoring well screen (minimum distance of travel); (5... effects during a lifetime. For purposes of this subpart, systemic toxicants include toxic chemicals that cause effects other than cancer or mutation. (ii) [Reserved] (j) In establishing ground-water protection...

  11. 40 CFR 258.55 - Assessment monitoring program.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... upgradient edge of the MSWLF unit and downgradient monitoring well screen (minimum distance of travel); (5... effects during a lifetime. For purposes of this subpart, systemic toxicants include toxic chemicals that cause effects other than cancer or mutation. (ii) [Reserved] (j) In establishing ground-water protection...

  12. Applying fiber optical methods for toxicological testing in vitro

    NASA Astrophysics Data System (ADS)

    Maerz, Holger K.; Buchholz, Rainer; Emmrich, Frank; Fink, Frank; Geddes, Clive L.; Pfeifer, Lutz; Raabe, Ferdinand; Scheper, Thomas-Helmut; Ulrich, Elizabeth; Marx, Uwe

    1999-04-01

    The new medical developments, e.g. immune therapy, patient oriented chemotherapy or even gene therapy, create a questionable doubt to the further requirement of animal test. Instead the call for humanitarian reproductive in vitro models becomes increasingly louder. Pharmaceutical usage of in vitro has a long proven history. In cancer research and therapy, the effect of chemostatica in vitro in the so-called oncobiogram is being tested; but the assays do not always correlate with in vivo-like drug resistance and sensitivity. We developed a drug test system in vitro, feasible for therapeutic drug monitoring by the combination of tissue cultivation in hollow fiber bioreactors and fiber optic sensors for monitoring the pharmaceutical effect. Using two fiber optic sensors - an optical oxygen sensor and a metabolism detecting Laserfluoroscope, we were able to successfully monitor the biological status of tissue culture and the drug or toxic effects of in vitro pharmaceutical testing. Furthermore, we developed and patented a system for monitoring the effect of minor toxic compounds which can induce Sick Building Syndrome.

  13. An assessment of a traffic monitoring system for a major traffic generator to improve regional planning : final presentation.

    DOT National Transportation Integrated Search

    2008-08-01

    Report Abstract: : The purpose of this guide is to aid the Texas Department of Transportation (TxDOT), Metropolitan Planning Organizations (MPO), and other state and local agencies to develop an effective traffic monitoring system for new major traff...

  14. Design and implementation of a remote UAV-based mobile health monitoring system

    NASA Astrophysics Data System (ADS)

    Li, Songwei; Wan, Yan; Fu, Shengli; Liu, Mushuang; Wu, H. Felix

    2017-04-01

    Unmanned aerial vehicles (UAVs) play increasing roles in structure health monitoring. With growing mobility in modern Internet-of-Things (IoT) applications, the health monitoring of mobile structures becomes an emerging application. In this paper, we develop a UAV-carried vision-based monitoring system that allows a UAV to continuously track and monitor a mobile infrastructure and transmit back the monitoring information in real- time from a remote location. The monitoring system uses a simple UAV-mounted camera and requires only a single feature located on the mobile infrastructure for target detection and tracking. The computation-effective vision-based tracking solution based on a single feature is an improvement over existing vision-based lead-follower tracking systems that either have poor tracking performance due to the use of a single feature, or have improved tracking performance at a cost of the usage of multiple features. In addition, a UAV-carried aerial networking infrastructure using directional antennas is used to enable robust real-time transmission of monitoring video streams over a long distance. Automatic heading control is used to self-align headings of directional antennas to enable robust communication in mobility. Compared to existing omni-communication systems, the directional communication solution significantly increases the operation range of remote monitoring systems. In this paper, we develop the integrated modeling framework of camera and mobile platforms, design the tracking algorithm, develop a testbed of UAVs and mobile platforms, and evaluate system performance through both simulation studies and field tests.

  15. Rater Accuracy and Training Group Effects in Expert- and Supervisor-Based Monitoring Systems

    ERIC Educational Resources Information Center

    Baird, Jo-Anne; Meadows, Michelle; Leckie, George; Caro, Daniel

    2017-01-01

    This study evaluated rater accuracy with rater-monitoring data from high stakes examinations in England. Rater accuracy was estimated with cross-classified multilevel modelling. The data included face-to-face training and monitoring of 567 raters in 110 teams, across 22 examinations, giving a total of 5500 data points. Two rater-monitoring systems…

  16. Study protocol for evaluating the implementation and effectiveness of an emergency department longitudinal patient monitoring system using a mixed-methods approach.

    PubMed

    Ward, Marie; McAuliffe, Eilish; Wakai, Abel; Geary, Una; Browne, John; Deasy, Conor; Schull, Michael; Boland, Fiona; McDaid, Fiona; Coughlan, Eoin; O'Sullivan, Ronan

    2017-01-23

    Early detection of patient deterioration is a key element of patient safety as it allows timely clinical intervention and potential rescue, thus reducing the risks of serious patient safety incidents. Longitudinal patient monitoring systems have been widely recommended for use to detect clinical deterioration. However, there is conflicting evidence on whether they improve patient outcomes. This may in part be related to variation in the rigour with which they are implemented and evaluated. This study aims to evaluate the implementation and effectiveness of a longitudinal patient monitoring system designed for adult patients in the unique environment of the Emergency Department (ED). A novel participatory action research (PAR) approach is taken where socio-technical systems (STS) theory and analysis informs the implementation through the improvement methodology of 'Plan Do Study Act' (PDSA) cycles. We hypothesise that conducting an STS analysis of the ED before beginning the PDSA cycles will provide for a much richer understanding of the current situation and possible challenges to implementing the ED-specific longitudinal patient monitoring system. This methodology will enable both a process and an outcome evaluation of implementing the ED-specific longitudinal patient monitoring system. Process evaluations can help distinguish between interventions that have inherent faults and those that are badly executed. Over 1.2 million patients attend EDs annually in Ireland; the successful implementation of an ED-specific longitudinal patient monitoring system has the potential to affect the care of a significant number of such patients. To the best of our knowledge, this is the first study combining PAR, STS and multiple PDSA cycles to evaluate the implementation of an ED-specific longitudinal patient monitoring system and to determine (through process and outcome evaluation) whether this system can significantly improve patient outcomes by early detection and appropriate intervention for patients at risk of clinical deterioration.

  17. [Design and implementation of real-time control of changes to national Chinese medicine resources fill system based on GIS].

    PubMed

    Zhang, Tian; Li, Jun-de; Cheng, Meng; Li, Ying; Lin, Zhong-Bin; Shen, Yi-Hua; Huang, Lu-Qi

    2017-11-01

    The dynamic monitoring data of traditional Chinese medicine resources is one of the important tasks of the dynamic monitoring system of Chinese medicine resources,the system has formed a periodic monitoring data reporting mechanism. Data authenticity and accuracy are the basis for the sustainable and healthy development of Chinese medicine resources dynamic monitoring,information technology is an effective means to improve the efficiency of data reporting, reporting quality. Data production based on dynamic monitoring is of great significance for grasp the trend of change and development of Chinese medicine resources. In order to achieve the real-time control of changes to the national Chinese medicine resources, we build the Chinese medicine resources dynamic monitoring system. In order to solve the problems in practice, we have upgraded the fill system by using the data of GIS. In order to achieve the multidimensional, improve safety, practicality and standardization of the data, which laid a foundation for subsequent processing of data. The system can collect the information of the cultivation of Chinese herbal medicines,production and sales of daily reporting data, provide the Chinese herbal medicine market,fast growing industry environment such as positioning center. In this paper, the design and implementation of the system are expounded.According to the business requirements, we designed 12 forms, 98 collection indicators to meet the needs of dynamic monitoring of traditional Chinese medicine resources. This paper will introduce the development content, design and implementation, main function characteristics and application effect of the national Chinese medicine resources fill System. To explain the role that GIS technology plays in the system and how to realize the cultivation of Chinese herbal medicines, production and sales of daily reporting data, provide the Chinese herbal medicine market,fast growing industry environment such as positioning center,and information collecting. Copyright© by the Chinese Pharmaceutical Association.

  18. Cost-Effectiveness of Remote Cardiac Monitoring With the CardioMEMS Heart Failure System.

    PubMed

    Schmier, Jordana K; Ong, Kevin L; Fonarow, Gregg C

    2017-07-01

    Heart failure (HF) is a leading cause of cardiovascular mortality in the United States and presents a substantial economic burden. A recently approved implantable wireless pulmonary artery pressure remote monitor, the CardioMEMS HF System, has been shown to be effective in reducing hospitalizations among New York Heart Association (NYHA) class III HF patients. The objective of this study was to estimate the cost-effectiveness of this remote monitoring technology compared to standard of care treatment for HF. A Markov cohort model relying on the CHAMPION (CardioMEMS Heart Sensor Allows Monitoring of Pressure to Improve Outcomes in NYHA Class III Heart Failure Patients) clinical trial for mortality and hospitalization data, published sources for cost data, and a mix of CHAMPION data and published sources for utility data, was developed. The model compares outcomes over 5 years for implanted vs standard of care patients, allowing patients to accrue costs and utilities while they remain alive. Sensitivity analyses explored uncertainty in input parameters. The CardioMEMS HF System was found to be cost-effective, with an incremental cost-effectiveness ratio of $44,832 per quality-adjusted life year (QALY). Sensitivity analysis found the model was sensitive to the device cost and to whether mortality benefits were sustained, although there were no scenarios in which the cost/QALY exceeded $100,000. Compared with standard of care, the CardioMEMS HF System was cost-effective when leveraging trial data to populate the model. © 2017 Wiley Periodicals, Inc.

  19. Traffic & rural intersection monitoring with a solar-based infrared wireless system : phase 2 final report, long term effect and justification for further analysis, May 2008 [summary].

    DOT National Transportation Integrated Search

    2008-05-01

    This study concerns the development and evaluation of a dynamic speed monitoring (DSM) system for use at rural intersections. The purpose of the DSM system is to give traffic speed feedback to drivers via an advisory sign, with the goals of improving...

  20. A ZigBee wireless networking for remote sensing applications in hydrological monitoring system

    NASA Astrophysics Data System (ADS)

    Weng, Songgan; Zhai, Duo; Yang, Xing; Hu, Xiaodong

    2017-01-01

    Hydrological monitoring is recognized as one of the most important factors in hydrology. Particularly, investigation of the tempo-spatial variation patterns of water-level and their effect on hydrological research has attracted more and more attention in recent. Because of the limitations in both human costs and existing water-level monitoring devices, however, it is very hard for researchers to collect real-time water-level data from large-scale geographical areas. This paper designs and implements a real-time water-level data monitoring system (MCH) based on ZigBee networking, which explicitly serves as an effective and efficient scientific instrument for domain experts to facilitate the measurement of large-scale and real-time water-level data monitoring. We implement a proof-of-concept prototype of the MCH, which can monitor water-level automatically, real-timely and accurately with low cost and low power consumption. The preliminary laboratory results and analyses demonstrate the feasibility and the efficacy of the MCH.

  1. Metrics for Assessing the Reliability of a Telemedicine Remote Monitoring System

    PubMed Central

    Fox, Mark; Papadopoulos, Amy; Crump, Cindy

    2013-01-01

    Abstract Objective: The goal of this study was to assess using new metrics the reliability of a real-time health monitoring system in homes of older adults. Materials and Methods: The “MobileCare Monitor” system was installed into the homes of nine older adults >75 years of age for a 2-week period. The system consisted of a wireless wristwatch-based monitoring system containing sensors for location, temperature, and impacts and a “panic” button that was connected through a mesh network to third-party wireless devices (blood pressure cuff, pulse oximeter, weight scale, and a survey-administering device). To assess system reliability, daily phone calls instructed participants to conduct system tests and reminded them to fill out surveys and daily diaries. Phone reports and participant diary entries were checked against data received at a secure server. Results: Reliability metrics assessed overall system reliability, data concurrence, study effectiveness, and system usability. Except for the pulse oximeter, system reliability metrics varied between 73% and 92%. Data concurrence for proximal and distal readings exceeded 88%. System usability following the pulse oximeter firmware update varied between 82% and 97%. An estimate of watch-wearing adherence within the home was quite high, about 80%, although given the inability to assess watch-wearing when a participant left the house, adherence likely exceeded the 10 h/day requested time. In total, 3,436 of 3,906 potential measurements were obtained, indicating a study effectiveness of 88%. Conclusions: The system was quite effective in providing accurate remote health data. The different system reliability measures identify important error sources in remote monitoring systems. PMID:23611640

  2. Design and Development of Intelligent Electrodes for Future Digital Health Monitoring: A Review

    NASA Astrophysics Data System (ADS)

    Khairuddin, A. M.; Azir, K. N. F. Ku; Kan, P. Eh

    2018-03-01

    Electrodes are sensors used in electrocardiography (ECG) monitoring system to diagnose heart diseases. Over the years, diverse types of electrodes have been designed and developed to improve ECG monitoring system. However, more recently, with the technological advances and capabilities from the Internet of Things (IoT), cloud computing and data analytics in personalized healthcare, researchers are attempting to design and develop more effective as well as flexible ECG devices by using intelligent electrodes. This paper reviews previous works on electrodes used in electrocardiography (ECG) monitoring devices to identify the key ftures for designing and developing intelligent electrodes in digital health monitoring devices.

  3. Flexible Sensing Electronics for Wearable/Attachable Health Monitoring.

    PubMed

    Wang, Xuewen; Liu, Zheng; Zhang, Ting

    2017-07-01

    Wearable or attachable health monitoring smart systems are considered to be the next generation of personal portable devices for remote medicine practices. Smart flexible sensing electronics are components crucial in endowing health monitoring systems with the capability of real-time tracking of physiological signals. These signals are closely associated with body conditions, such as heart rate, wrist pulse, body temperature, blood/intraocular pressure and blood/sweat bio-information. Monitoring such physiological signals provides a convenient and non-invasive way for disease diagnoses and health assessments. This Review summarizes the recent progress of flexible sensing electronics for their use in wearable/attachable health monitoring systems. Meanwhile, we present an overview of different materials and configurations for flexible sensors, including piezo-resistive, piezo-electrical, capacitive, and field effect transistor based devices, and analyze the working principles in monitoring physiological signals. In addition, the future perspectives of wearable healthcare systems and the technical demands on their commercialization are briefly discussed. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Monitoring and analysis of liquid storage in LNG tank based on different support springs

    NASA Astrophysics Data System (ADS)

    He, Hua; Sun, Jianping; Li, Ke; Wu, Zheng; Chen, Qidong; Chen, Guodong; Cao, Can

    2018-04-01

    With the rapid development of social modernization, LNG vehicles are springing up in daily life. However, it is difficult to monitor and judge the liquid storage tanks accurately and quickly. Based on this, this paper presents a new method of liquid storage monitoring, LNG tank on-line vibration monitoring system. By collecting the vibration frequency of LNG tank and tank liquid and supporting spring system, the liquid storage quality in the tank can be calculated. In this experiment, various vibration modes of the tank spring system are fully taken into account. The vibration effects of different types of support springs on the LNG tank system were investigated. The results show that the spring model has a great influence on the test results. This study provides a technical reference for the selection of suitable support springs for liquid storage monitoring.

  5. A Model of Managerial Effectiveness in Information Security: From Grounded Theory to Empirical Test

    DTIC Science & Technology

    2005-09-13

    to observe employee performance (George, 1996) and encourage policy adherence ( Ariss , 2002) have been studied. While the published academic...for excessive monitoring ( Ariss , 2002). Managers have a key role to play in designing monitoring and enforcement systems that are effective yet not... Ariss , S. S. (2002). Computer Monitoring: Benefits and Pitfalls Facing Management. Information & Management, 39(7), 553-558. Armstrong, C. P

  6. A distributed cloud-based cyberinfrastructure framework for integrated bridge monitoring

    NASA Astrophysics Data System (ADS)

    Jeong, Seongwoon; Hou, Rui; Lynch, Jerome P.; Sohn, Hoon; Law, Kincho H.

    2017-04-01

    This paper describes a cloud-based cyberinfrastructure framework for the management of the diverse data involved in bridge monitoring. Bridge monitoring involves various hardware systems, software tools and laborious activities that include, for examples, a structural health monitoring (SHM), sensor network, engineering analysis programs and visual inspection. Very often, these monitoring systems, tools and activities are not coordinated, and the collected information are not shared. A well-designed integrated data management framework can support the effective use of the data and, thereby, enhance bridge management and maintenance operations. The cloud-based cyberinfrastructure framework presented herein is designed to manage not only sensor measurement data acquired from the SHM system, but also other relevant information, such as bridge engineering model and traffic videos, in an integrated manner. For the scalability and flexibility, cloud computing services and distributed database systems are employed. The information stored can be accessed through standard web interfaces. For demonstration, the cyberinfrastructure system is implemented for the monitoring of the bridges located along the I-275 Corridor in the state of Michigan.

  7. Monitoring SLAC High Performance UNIX Computing Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lettsome, Annette K.; /Bethune-Cookman Coll. /SLAC

    2005-12-15

    Knowledge of the effectiveness and efficiency of computers is important when working with high performance systems. The monitoring of such systems is advantageous in order to foresee possible misfortunes or system failures. Ganglia is a software system designed for high performance computing systems to retrieve specific monitoring information. An alternative storage facility for Ganglia's collected data is needed since its default storage system, the round-robin database (RRD), struggles with data integrity. The creation of a script-driven MySQL database solves this dilemma. This paper describes the process took in the creation and implementation of the MySQL database for use by Ganglia.more » Comparisons between data storage by both databases are made using gnuplot and Ganglia's real-time graphical user interface.« less

  8. A New Frontier for Cardiac Monitoring

    NASA Technical Reports Server (NTRS)

    2001-01-01

    CardioDynamics International Corporation (CDIC) has created the BioZ(TM) System through a Small Business Innovation Research (SBIR) award from Johnson Space Center, providing patients and physicians with a cost-effective and highly accurate monitoring system.The BioZ non-invasive heart monitor is based on a technology known as Impedance Cardiography (ICG). BioZ provides the physician with vital information about the heart's ability to deliver blood to the body, the force one's heart exerts with each beat, and the amount of fluid in the chest. Specially designed bioimpedance sensors placed on the neck and chest monitor 12 different parameters, including cardiac output, contractility, systemic vascular resistance, and thoracic fluid content. These sensors monitor the electrical conductivity of the body-information that is converted into blood flow data and is displayed in real time on a monitoring screen. BioZ.com(TM) and BioZ.pc(TM) are two additional products that incorporate the same sensors present in the original BioZ system. The "com" in BioZ.com stands for cardiac output monitor. This fully integrated system is essentially a smaller version of the BioZ, combining the same abilities with a compact, lightweight design, while providing greater portability.

  9. Earth physicist describes US nuclear test monitoring system

    NASA Astrophysics Data System (ADS)

    1986-01-01

    The U. S. capabilities to monitor underground nuclear weapons tests in the USSR was examined. American methods used in monitoring the underground nuclear tests are enumerated. The U. S. technical means of monitoring Solviet nuclear weapons testing, and whether it is possible to conduct tests that could not be detected by these means are examined. The worldwide seismic station network in 55 countries available to the U. S. for seismic detection and measurement of underground nuclear explosions, and also the systems of seismic research observatories in 15 countries and seismic grouping stations in 12 countries are outlined including the advanced computerized data processing capabilities of these facilities. The level of capability of the U. S. seismic system for monitoring nuclear tests, other, nonseismic means of monitoring, such as hydroacoustic and recording of effects in the atmosphere, ionosphere, and the Earth's magnetic field, are discussed.

  10. Design and Realization of Online Monitoring System of Distributed New Energy and Renewable Energy

    NASA Astrophysics Data System (ADS)

    Tang, Yanfen; Zhou, Tao; Li, Mengwen; Zheng, Guotai; Li, Hao

    2018-01-01

    Aimed at difficult centralized monitoring and management of current distributed new energy and renewable energy generation projects due to great varieties, different communication protocols and large-scale difference, this paper designs a online monitoring system of new energy and renewable energy characterized by distributed deployment, tailorable functions, extendible applications and fault self-healing performance. This system is designed based on international general standard for grid information data model, formulates unified data acquisition and transmission standard for different types of new energy and renewable energy generation projects, and can realize unified data acquisition and real-time monitoring of new energy and renewable energy generation projects, such as solar energy, wind power, biomass energy, etc. within its jurisdiction. This system has applied in Beijing. At present, 576 projects are connected to the system. Good effect is achieved and stability and reliability of the system have been validated.

  11. Monitoring operational data production applying Big Data tooling

    NASA Astrophysics Data System (ADS)

    Som de Cerff, Wim; de Jong, Hotze; van den Berg, Roy; Bos, Jeroen; Oosterhoff, Rijk; Klein Ikkink, Henk Jan; Haga, Femke; Elsten, Tom; Verhoef, Hans; Koutek, Michal; van de Vegte, John

    2015-04-01

    Within the KNMI Deltaplan programme for improving the KNMI operational infrastructure an new fully automated system for monitoring the KNMI operational data production systems is being developed: PRISMA (PRocessflow Infrastructure Surveillance and Monitoring Application). Currently the KNMI operational (24/7) production systems consist of over 60 applications, running on different hardware systems and platforms. They are interlinked for the production of numerous data products, which are delivered to internal and external customers. All applications are individually monitored by different applications, complicating root cause and impact analysis. Also, the underlying hardware and network is monitored separately using Zabbix. Goal of the new system is to enable production chain monitoring, which enables root cause analysis (what is the root cause of the disruption) and impact analysis (what other products will be effected). The PRISMA system will make it possible to dispose all the existing monitoring applications, providing one interface for monitoring the data production. For modeling the production chain, the Neo4j Graph database is used to store and query the model. The model can be edited through the PRISMA web interface, but is mainly automatically provided by the applications and systems which are to be monitored. The graph enables us to do root case and impact analysis. The graph can be visualized in the PRISMA web interface on different levels. Each 'monitored object' in the model will have a status (OK, error, warning, unknown). This status is derived by combing all log information available. For collecting and querying the log information Splunk is used. The system is developed using Scrum, by a multi-disciplinary team consisting of analysts, developers, a tester and interaction designer. In the presentation we will focus on the lessons learned working with the 'Big data' tooling Splunk and Neo4J.

  12. Economic Evaluation of a Home-Based Age-Related Macular Degeneration Monitoring System.

    PubMed

    Wittenborn, John S; Clemons, Traci; Regillo, Carl; Rayess, Nadim; Liffmann Kruger, Danielle; Rein, David

    2017-05-01

    Medicare recently approved coverage of home telemonitoring for early detection of incident choroidal neovascularization (CNV) among patients with age-related macular degeneration (AMD), but no economic evaluation has yet assessed its cost-effectiveness and budgetary impact. To evaluate a home-based daily visual-field monitoring system using simulation methods and to apply the findings of the Home Monitoring of the Eye study to the US population at high risk for wet-form AMD. In this economic analysis, an evaluation of the potential cost, cost-effectiveness, and government budgetary impact of adoption of a home-based daily visual-field monitoring system among eligible Medicare patients was performed. Effectiveness and visual outcomes data from the Age-Related Eye Disease Study 2 Home Monitoring of the Eye study, treatment data from the Wills Eye Hospital Treat & Extend study, and AMD progression data from the Age-Related Eye Disease Study 1 were used to simulate the long-term effects of telemonitoring patients with CNV in one eye or large drusen and/or pigment abnormalities in both eyes. Univariate and probabilistic sensitivity analysis and an alternative scenario using the Treat & Extend study control group outcomes were used to examine uncertainty in these data and assumptions. Home telemonitoring of patients with AMD for early detection of CNV vs usual care. Incremental cost-effectiveness ratio, net present value of lifetime societal costs, and 10-year nominal government expenditures. Telemonitoring of patients with existing unilateral CNV or multiple bilateral risk factors for CNV (large drusen and retinal pigment abnormalities) incurs $907 (95% CI, -$6302 to $2809) in net lifetime societal costs, costs $1312 (95% CI, $222-$2848) per patient during 10 years from the federal government's perspective, and results in an incremental cost-effectiveness ratio of $35 663 (95% CI, cost savings to $235 613) per quality-adjusted life-year gained. Home telemonitoring of patients with AMD who are at risk for CNV was cost-effective compared with scheduled examinations alone. Monitoring patients with existing CNV in one eye is cost saving, but monitoring is generally not cost-effective among patients with low risk of CNV, including those with no or few risk factors. With Medicare coverage, monitoring incurs budgetary expenditures for the government but is cost-saving for patients at high risk of AMD. Monitoring could be cost saving to society if monitoring reduced the frequency of scheduled examinations or led to a reduction of one or more injections of ranibizumab.

  13. 76 FR 2011 - High Seas Driftnet Fishing Moratorium Protection Act; Identification and Certification Procedures...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-01-12

    ... unauthorized or other IUU catch; Catch and effort monitoring, including licensing and permitting schemes, reporting, and vessel monitoring systems (VMS); Bycatch reduction and mitigation strategies and techniques... effective sanctions and monitoring, control and surveillance (MCS) capacity; and Participation in voluntary...

  14. Development of a portable Linux-based ECG measurement and monitoring system.

    PubMed

    Tan, Tan-Hsu; Chang, Ching-Su; Huang, Yung-Fa; Chen, Yung-Fu; Lee, Cheng

    2011-08-01

    This work presents a portable Linux-based electrocardiogram (ECG) signals measurement and monitoring system. The proposed system consists of an ECG front end and an embedded Linux platform (ELP). The ECG front end digitizes 12-lead ECG signals acquired from electrodes and then delivers them to the ELP via a universal serial bus (USB) interface for storage, signal processing, and graphic display. The proposed system can be installed anywhere (e.g., offices, homes, healthcare centers and ambulances) to allow people to self-monitor their health conditions at any time. The proposed system also enables remote diagnosis via Internet. Additionally, the system has a 7-in. interactive TFT-LCD touch screen that enables users to execute various functions, such as scaling a single-lead or multiple-lead ECG waveforms. The effectiveness of the proposed system was verified by using a commercial 12-lead ECG signal simulator and in vivo experiments. In addition to its portability, the proposed system is license-free as Linux, an open-source code, is utilized during software development. The cost-effectiveness of the system significantly enhances its practical application for personal healthcare.

  15. Case Study on the Maintenance of a Construction Monitoring Using USN-Based Data Acquisition

    PubMed Central

    Kim, Sangyong; Shin, Yoonseok; Kim, Gwang-Hee

    2014-01-01

    In recent years, there has been an increasing interest in the adoption of emerging ubiquitous sensor network (USN) technologies for instrumentation within a variety of sustainability systems. USN is emerging as a sensing paradigm that is being newly considered by the sustainability management field as an alternative to traditional tethered monitoring systems. Researchers have been discovering that USN is an exciting technology that should not be viewed simply as a substitute for traditional tethered monitoring systems. In this study, we investigate how a movement monitoring measurement system of a complex building is developed as a research environment for USN and related decision-supportive technologies. To address the apparent danger of building movement, agent-mediated communication concepts have been designed to autonomously manage large volumes of exchanged information. In this study, we additionally detail the design of the proposed system, including its principles, data processing algorithms, system architecture, and user interface specifics. Results of the test and case study demonstrate the effectiveness of the USN-based data acquisition system for real-time monitoring of movement operations. PMID:25097890

  16. Case study on the maintenance of a construction monitoring using USN-based data acquisition.

    PubMed

    Kim, Sangyong; Shin, Yoonseok; Kim, Gwang-Hee

    2014-01-01

    In recent years, there has been an increasing interest in the adoption of emerging ubiquitous sensor network (USN) technologies for instrumentation within a variety of sustainability systems. USN is emerging as a sensing paradigm that is being newly considered by the sustainability management field as an alternative to traditional tethered monitoring systems. Researchers have been discovering that USN is an exciting technology that should not be viewed simply as a substitute for traditional tethered monitoring systems. In this study, we investigate how a movement monitoring measurement system of a complex building is developed as a research environment for USN and related decision-supportive technologies. To address the apparent danger of building movement, agent-mediated communication concepts have been designed to autonomously manage large volumes of exchanged information. In this study, we additionally detail the design of the proposed system, including its principles, data processing algorithms, system architecture, and user interface specifics. Results of the test and case study demonstrate the effectiveness of the USN-based data acquisition system for real-time monitoring of movement operations.

  17. Evaluation of submarine strain-gage systems for monitoring coastal sediment migration

    NASA Technical Reports Server (NTRS)

    Shideler, G. L.; Mcgrath, D. G.

    1973-01-01

    Single and multiple strain-gage systems were respectively evaluated as in situ point and areal sensors for monitoring sand-height variations in coastal environments. Static loading tests indicate that gage response pressure is linear for sand heights up to 24 inches. Response pressures are a function of both sand height and aggregate density, with density being influenced by both sediment texture and degree of compaction. Poorer sediment sorting and greater compaction result in higher response pressures. Field tests in a beach foreshore environment indicate that the gage systems are effective qualitative instruments for monitoring long-period migration trends of beach sediments; whereas, short-period responses are not sufficiently reliable. The durability and compactness of the gage systems must be substantially increased for effective field operations. It is recommended that the systems' qualitative potentials be further developed, whereas their development as quantitative instruments be terminated. Further development should emphasize the construction of remote recording systems designed for semipermanent installation.

  18. Improving compliance in remote healthcare systems through smartphone battery optimization.

    PubMed

    Alshurafa, Nabil; Eastwood, Jo-Ann; Nyamathi, Suneil; Liu, Jason J; Xu, Wenyao; Ghasemzadeh, Hassan; Pourhomayoun, Mohammad; Sarrafzadeh, Majid

    2015-01-01

    Remote health monitoring (RHM) has emerged as a solution to help reduce the cost burden of unhealthy lifestyles and aging populations. Enhancing compliance to prescribed medical regimens is an essential challenge to many systems, even those using smartphone technology. In this paper, we provide a technique to improve smartphone battery consumption and examine the effects of smartphone battery lifetime on compliance, in an attempt to enhance users' adherence to remote monitoring systems. We deploy WANDA-CVD, an RHM system for patients at risk of cardiovascular disease (CVD), using a wearable smartphone for detection of physical activity. We tested the battery optimization technique in an in-lab pilot study and validated its effects on compliance in the Women's Heart Health Study. The battery optimization technique enhanced the battery lifetime by 192% on average, resulting in a 53% increase in compliance in the study. A system like WANDA-CVD can help increase smartphone battery lifetime for RHM systems monitoring physical activity.

  19. Effectiveness of a simple and real-time baseline shift monitoring system during stereotactic body radiation therapy of lung tumors.

    PubMed

    Uchida, Yukihiro; Tachibana, Hidenobu; Kamei, Yoshiyuki; Kashihara, Kenichi

    2017-11-01

    This study aimed to clinically validate a simple real-time baseline shift monitoring system in a prospective study of consecutive patients undergoing stereotactic body radiation therapy (SBRT) of lung tumors, and to investigate baseline shift due to intrafraction motion of the patient's body during lung SBRT. Ten consecutive patients with peripheral lung tumors were treated by SBRT consisting of four fractions of 12 Gy each, with a total dose of 48 Gy. During treatment, each patient's geometric displacement in the anterior-posterior and left-right directions (the baseline shift) was measured using a real-time monitoring webcam system. Displacement between the start and end of treatment was measured using an X-ray fluoroscopic imaging system. The displacement measurements of the two systems were compared, and the measurements of baseline shift acquired by the monitoring system during treatment were analyzed for all patients. There was no significant deviation between the monitoring system and the X-ray imaging system, with the accuracy of measurement being within 1 mm. Measurements using the monitoring system showed that 7 min of treatment generated displacements of more than 1 mm in 50% of the patients. Baseline shift of a patient's body may be measured accurately in real time, using a monitoring system without X-ray exposure. The manubrium of the sternum is a good location for measuring the baseline shift of a patient's body at all times. The real-time monitoring system may be useful for measuring the baseline shift of a patient's body independently of a gating system. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  20. Experimental investigation of leak detection using mobile distributed monitoring system

    NASA Astrophysics Data System (ADS)

    Chen, Jiang; Zheng, Junli; Xiong, Feng; Ge, Qi; Yan, Qixiang; Cheng, Fei

    2018-01-01

    The leak detection of rockfill dams is currently hindered by spatial and temporal randomness and wide monitoring range. The spatial resolution of fiber Bragg grating (FBG) temperature sensing technology is related to the distance between measuring points. As a result, the number of measuring points should be increased to ensure that the precise location of the leak is detected. However, this leads to a higher monitoring cost. Consequently, it is difficult to promote and apply this technology to effectively monitor rockfill dam leakage. In this paper, a practical mobile distributed monitoring system with dual-tubes is used by combining the FBG sensing system and hydrothermal cycling system. This dual-tube structure is composed of an outer polyethylene of raised temperature resistance heating pipe, an inner polytetrafluoroethylene tube, and a FBG sensor string, among which, the FBG sensor string can be dragged freely in the internal tube to change the position of the measuring points and improve the spatial resolution. In order to test the effectiveness of the system, the large-scale model test of concentrated leakage in 13 working conditions is carried out by identifying the location, quantity, and leakage rate of leakage passage. Based on Newton’s law of cooling, the leakage state is identified using the seepage identification index ζ v that was confirmed according to the cooling curve. Results suggested that the monitoring system shows high sensitivity and can improve the spatial resolution with limited measuring points, and thus better locate the leakage area. In addition, the seepage identification index ζ v correlated well with the leakage rate qualitatively.

  1. A design of the u-health monitoring system using a Nintendo DS game machine.

    PubMed

    Lee, Sangjoon; Kim, Jinkwon; Kim, Jungkuk; Lee, Myoungho

    2009-01-01

    In this paper, we used the hand held type a Nintendo DS Game Machine for consisting of a u-Health Monitoring system. This system is consists of four parts. Biosignal acquire device is the first. The Second is a wireless sensor network device. The third is a wireless base-station for connecting internet network. Displaying units are the last part which were a personal computer and a Nintendo DS game machine. The bio-signal measurement device among the four parts the u-health monitoring system can acquire 7-channels data which have 3-channels ECG(Electrocardiogram), 3-axis accelerometer and tilting sensor data. Acquired data connect up the internet network throughout the wireless sensor network and a base-station. In the experiment, we concurrently display the bio-signals on to a monitor of personal computer and LCD of a Nintendo DS using wireless internet protocol and those monitoring devices placed off to the one side an office building. The result of the experiment, this proposed system effectively can transmit patient's biosignal data as a long time and a long distance. This suggestion of the u-health monitoring system need to operate in the ambulance, general hospitals and geriatric institutions as a u-health monitoring device.

  2. Computer-aided video exposure monitoring.

    PubMed

    Walsh, P T; Clark, R D; Flaherty, S; Gentry, S J

    2000-01-01

    A computer-aided video exposure monitoring system was used to record exposure information. The system comprised a handheld camcorder, portable video cassette recorder, radio-telemetry transmitter/receiver, and handheld or notebook computers for remote data logging, photoionization gas/vapor detectors (PIDs), and a personal aerosol monitor. The following workplaces were surveyed using the system: dry cleaning establishments--monitoring tetrachoroethylene in the air and in breath; printing works--monitoring white spirit type solvent; tire manufacturing factory--monitoring rubber fume; and a slate quarry--monitoring respirable dust and quartz. The system based on the handheld computer, in particular, simplified the data acquisition process compared with earlier systems in use by our laboratory. The equipment is more compact and easier to operate, and allows more accurate calibration of the instrument reading on the video image. Although a variety of data display formats are possible, the best format for videos intended for educational and training purposes was the review-preview chart superimposed on the video image of the work process. Recommendations for reducing exposure by engineering or by modifying work practice were possible through use of the video exposure system in the dry cleaning and tire manufacturing applications. The slate quarry work illustrated how the technique can be used to test ventilation configurations quickly to see their effect on the worker's personal exposure.

  3. An internet-based wearable watch-over system for elderly and disabled utilizing EMG and accelerometer.

    PubMed

    Kishimoto, M; Yoshida, T; Hayasaka, T; Mori, D; Imai, Y; Matsuki, N; Ishikawa, T; Yamaguchi, T

    2009-01-01

    An effective way for preventing injuries and diseases among the elderly is to monitor their daily lives. In this regard, we propose the use of a "Hyper Hospital Network", which is an information support system for elderly people and patients. In the current study, we developed a wearable system for monitoring electromyography (EMG) and acceleration using the Hyper Hospital Network plan. The current system is an upgraded version of our previous system for gait analysis (Yoshida et al. [13], Telemedicine and e-Health 13 703-714), and lets us monitor decreases in exercise and the presence of a hemiplegic gait more accurately. To clarify the capabilities and reliability of the system, we performed three experimental evaluations: one to verify the performance of the wearable system, a second to detect a hemiplegic gait, and a third to monitor EMG and accelerations simultaneously. Our system successfully detected a lack of exercise by monitoring the iEMG in healthy volunteers. Moreover, by using EMG and acceleration signals simultaneously, the reliability of the Hampering Index (HI) for detecting hemiplegia walking was improved significantly. The present study provides useful knowledge for the development of a wearable computer designed to monitor the physical conditions of older persons and patients.

  4. Forest Health Monitoring and Forest Inventory Analysis programs monitor climate change effects in forest ecosystems

    Treesearch

    Kenneth W. Stolte

    2001-01-01

    The Forest Health Monitoring (FHM) and Forest Inventory and Analyses (FIA) programs are integrated bilogical monitoring systems that use nationally standardized methods to evaluate and report on the health and sustainability of forest ecosystems in the United States. Many of the anticipated changes in forest ecosystems from climate change were also issues addressed in...

  5. 75 FR 31811 - Endangered and Threatened Wildlife and Plants; Post-Delisting Monitoring Plan for Bald Eagle...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-04

    ... Species Act (ESA) requires that we implement a system, in cooperation with the States, to monitor... cooperation with the States, to effectively monitor for not less than 5 years the status of all species that... stratified sampling based on density of identified bald eagle nest sites. Our Bald Eagle Monitoring Team will...

  6. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dudleson, B.; Arnold, M.; McCann, D.

    Rapid detection of unexpected drilling events requires continuous monitoring of drilling parameters. A major R and D program by a drilling contractor has led to the introduction of a computerized monitoring system on its offshore rigs. System includes advanced color graphics displays and new smart alarms to help both contractor and operator personnel detect and observe drilling events before they would normally be apparent with conventional rig instrumentation. This article describes a module of this monitoring system, which uses expert system technology to detect the earliest stages of drillstring washouts. Field results demonstrate the effectiveness of the smart alarm incorporatedmore » in the system. Early detection allows the driller to react before a twist-off results in expensive fishing operations.« less

  7. Patient-centered technological assessment and monitoring of depression for low-income patients.

    PubMed

    Wu, Shinyi; Vidyanti, Irene; Liu, Pai; Hawkins, Caitlin; Ramirez, Magaly; Guterman, Jeffrey; Gross-Schulman, Sandra; Sklaroff, Laura Myerchin; Ell, Kathleen

    2014-01-01

    Depression is a significant challenge for ambulatory care because it worsens health status and outcomes, increases health care utilizations and costs, and elevates suicide risk. An automatic telephonic assessment (ATA) system that links with tasks and alerts to providers may improve quality of depression care and increase provider productivity. We used ATA system in a trial to assess and monitor depressive symptoms of 444 safety-net primary care patients with diabetes. We assessed system properties, evaluated preliminary clinical outcomes, and estimated cost savings. The ATA system is feasible, reliable, valid, safe, and likely cost-effective for depression screening and monitoring for low-income primary care population.

  8. [Development of a continuous blood pressure monitoring and recording system].

    PubMed

    Zhang, Yang; Li, Yong; Gao, Shumei; Song, Yilin

    2012-09-01

    A small experimental system is constructed with working principle of continuous blood pressure monitoring based on the volume compensation method. The preliminary experimental results show that the system can collect blood pressure signals at the radial artery effectively. The digital PID algorithm can track the variation of blood pressure. And the accuracy of continuous blood pressure detecting achieve the level of same kind of product.

  9. [Newly developed monitor for IVR: liquid crystal display (LCD) replaced with cathode ray tube (CRT)].

    PubMed

    Ichida, Takao; Hosogai, Minoru; Yokoyama, Kouji; Ogawa, Takayoshi; Okusako, Kenji; Shougaki, Masachika; Masai, Hironao; Yamada, Eiji; Okuyama, Kazuo; Hatagawa, Masakatsu

    2004-09-01

    For physicians who monitor images during interventional radiology (VR), we have built and been using a system that employs a liquid crystal display (LCD) instead of the conventional cathode ray tube (CRT). The system incorporates a ceiling-suspension-type monitor (three-display monitor) with an LCD on each of the three displays for the head and abdominal regions and another ceiling-suspension-type monitor (5-display monitor) with an LCD on each display for the cardiac region. As these monitors are made to be thin and light in weight, they can be placed in a high position in the room, thereby saving space and allowing for more effective use of space in the X-ray room. The system has also improved the efficiency of operators in the IVR room. The three-display folding mechanism allows the displays to be viewed from multiple directions, thereby improving the environment so that the performance of IVR can be observed.

  10. The design of the intelligent monitoring system for dam safety

    NASA Astrophysics Data System (ADS)

    Yuan, Chun-qiao; Jiang, Chen-guang; Wang, Guo-hui

    2008-12-01

    Being a vital manmade water-control structure, a dam plays a very important role in the living and production of human being. To make a dam run safely, the best design and the superior construction quality are paramount; moreover, with working periods increasing, various dynamic, alternative and bad loads generate little by little various distortions on the dam structure inevitably, which shall lead to potential safety problems or further a disaster (dam burst). There are many signs before the occurrence of a dam accident, so the timely and effective surveying on the distortion of a dam is important. On the basis of the cause supra, two intelligent (automatic) monitoring systems about the dam's safety based on the RTK-GPS technology and the measuring robot has been developed. The basic principle, monitoring method and monitoring process of these two intelligent (automatic) monitoring systems are introduced. It presents examples of monitor and puts forward the basic rule of dam warning based on data of actual monitor.

  11. Development of cost effective fenceline monitoring approaches to support advanced leak detection and repair strategies

    EPA Science Inventory

    Cost-effective fence line and process monitoring systems to support advanced leak detection and repair (LDAR) strategies can enhance protection of public health, facilitate worker safety, and help companies realize cost savings by reducing lost product. The U.S. EPA Office of Re...

  12. 78 FR 7411 - Vessel Monitoring Systems (VMS); Certification of New VMS Unit for Use in Northeast Fisheries

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-01

    ... Monitoring Systems (VMS); Certification of New VMS Unit for Use in Northeast Fisheries AGENCY: National... used effective January 24, 2013. FOR FURTHER INFORMATION CONTACT: Office of Law Enforcement, Northeast Division, Northeast VMS Team, telephone 978-281-9213. SUPPLEMENTARY INFORMATION: Regulations at 50 CFR 648...

  13. Effect of Technology-Enhanced Continuous Progress Monitoring on Math Achievement

    ERIC Educational Resources Information Center

    Ysseldyke, Jim; Bolt, Daniel M.

    2007-01-01

    We examined the extent to which use of a technology-enhanced continuous progress monitoring system would enhance the results of math instruction, examined variability in teacher implementation of the program, and compared math results in classrooms in which teachers did and did not use the system. Classrooms were randomly assigned to within-school…

  14. Benefits of remote real-time side-effect monitoring systems for patients receiving cancer treatment.

    PubMed

    Kofoed, Sarah; Breen, Sibilah; Gough, Karla; Aranda, Sanchia

    2012-03-05

    In Australia, the incidence of cancer diagnoses is rising along with an aging population. Cancer treatments, such as chemotherapy, are increasingly being provided in the ambulatory care setting. Cancer treatments are commonly associated with distressing and serious side-effects and patients often struggle to manage these themselves without specialized real-time support. Unlike chronic disease populations, few systems for the remote real-time monitoring of cancer patients have been reported. However, several prototype systems have been developed and have received favorable reports. This review aimed to identify and detail systems that reported statistical analyses of changes in patient clinical outcomes, health care system usage or health economic analyses. Five papers were identified that met these criteria. There was wide variation in the design of the monitoring systems in terms of data input method, clinician alerting and response, groups of patients targeted and clinical outcomes measured. The majority of studies had significant methodological weaknesses. These included no control group comparisons, small sample sizes, poor documentation of clinical interventions or measures of adherence to the monitoring systems. In spite of the limitations, promising results emerged in terms of improved clinical outcomes (e.g. pain, depression, fatigue). Health care system usage was assessed in two papers with inconsistent results. No studies included health economic analyses. The diversity in systems described, outcomes measured and methodological issues all limited between-study comparisons. Given the acceptability of remote monitoring and the promising outcomes from the few studies analyzing patient or health care system outcomes, future research is needed to rigorously trial these systems to enable greater patient support and safety in the ambulatory setting.

  15. Benefits of remote real-time side-effect monitoring systems for patients receiving cancer treatment

    PubMed Central

    Kofoed, Sarah; Breen, Sibilah; Gough, Karla; Aranda, Sanchia

    2012-01-01

    In Australia, the incidence of cancer diagnoses is rising along with an aging population. Cancer treatments, such as chemotherapy, are increasingly being provided in the ambulatory care setting. Cancer treatments are commonly associated with distressing and serious side-effects and patients often struggle to manage these themselves without specialized real-time support. Unlike chronic disease populations, few systems for the remote real-time monitoring of cancer patients have been reported. However, several prototype systems have been developed and have received favorable reports. This review aimed to identify and detail systems that reported statistical analyses of changes in patient clinical outcomes, health care system usage or health economic analyses. Five papers were identified that met these criteria. There was wide variation in the design of the monitoring systems in terms of data input method, clinician alerting and response, groups of patients targeted and clinical outcomes measured. The majority of studies had significant methodological weaknesses. These included no control group comparisons, small sample sizes, poor documentation of clinical interventions or measures of adherence to the monitoring systems. In spite of the limitations, promising results emerged in terms of improved clinical outcomes (e.g. pain, depression, fatigue). Health care system usage was assessed in two papers with inconsistent results. No studies included health economic analyses. The diversity in systems described, outcomes measured and methodological issues all limited between-study comparisons. Given the acceptability of remote monitoring and the promising outcomes from the few studies analyzing patient or health care system outcomes, future research is needed to rigorously trial these systems to enable greater patient support and safety in the ambulatory setting. PMID:25992209

  16. Development of a robust and cost-effective 3D respiratory motion monitoring system using the kinect device: Accuracy comparison with the conventional stereovision navigation system.

    PubMed

    Bae, Myungsoo; Lee, Sangmin; Kim, Namkug

    2018-07-01

    To develop and validate a robust and cost-effective 3D respiratory monitoring system based on a Kinect device with a custom-made simple marker. A 3D respiratory monitoring system comprising the simple marker and the Microsoft Kinect v2 device was developed. The marker was designed for simple and robust detection, and the tracking algorithm was developed using the depth, RGB, and infra-red images acquired from the Kinect sensor. A Kalman filter was used to suppress movement noises. The major movements of the marker attached to the four different locations of body surface were determined from the initially collected tracking points of the marker while breathing. The signal level of respiratory motion with the tracking point was estimated along the major direction vector. The accuracy of the results was evaluated through a comparison with those of the conventional stereovision navigation system (NDI Polaris Spectra). Sixteen normal volunteers were enrolled to evaluate the accuracy of this system. The correlation coefficients between the respiratory motion signal from the Kinect device and conventional navigation system ranged from 0.970 to 0.999 and from 0.837 to 0.995 at the abdominal and thoracic surfaces, respectively. The respiratory motion signal from this system was obtained at 27-30 frames/s. This system with the Kinect v2 device and simple marker could be used for cost-effective, robust and accurate 3D respiratory motion monitoring. In addition, this system is as reliable for respiratory motion signal generation and as practically useful as the conventional stereovision navigation system and is less sensitive to patient posture. Copyright © 2018 Elsevier B.V. All rights reserved.

  17. The design of tea garden environmental monitoring system based on WSN

    NASA Astrophysics Data System (ADS)

    Chen, Huajun; Yuan, Lina

    2018-01-01

    Through the application of wireless sensor network (WSN) in tea garden, it can realize the change of traditional tea garden to the modern ones, and effectively improves the comprehensive productive capacity of tea garden. According to the requirement of real-time remote in agricultural information collection and monitoring and the power supply affected by environmental limitations, based on WSN, this paper designs a set of tea garden environmental monitoring system, which achieves the monitoring nodes with ad-hoc network as well as automatic acquisition and transmission to the tea plantations of air temperature, light intensity, soil temperature and humidity.

  18. Information technologies in optimization process of monitoring of software and hardware status

    NASA Astrophysics Data System (ADS)

    Nikitin, P. V.; Savinov, A. N.; Bazhenov, R. I.; Ryabov, I. V.

    2018-05-01

    The article describes a model of a hardware and software monitoring system for a large company that provides customers with software as a service (SaaS solution) using information technology. The main functions of the monitoring system are: provision of up-todate data for analyzing the state of the IT infrastructure, rapid detection of the fault and its effective elimination. The main risks associated with the provision of these services are described; the comparative characteristics of the software are given; author's methods of monitoring the status of software and hardware are proposed.

  19. New approach to information fusion for Lipschitz classifiers ensembles: Application in multi-channel C-OTDR-monitoring systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Timofeev, Andrey V.; Egorov, Dmitry V.

    This paper presents new results concerning selection of an optimal information fusion formula for an ensemble of Lipschitz classifiers. The goal of information fusion is to create an integral classificatory which could provide better generalization ability of the ensemble while achieving a practically acceptable level of effectiveness. The problem of information fusion is very relevant for data processing in multi-channel C-OTDR-monitoring systems. In this case we have to effectively classify targeted events which appear in the vicinity of the monitored object. Solution of this problem is based on usage of an ensemble of Lipschitz classifiers each of which corresponds tomore » a respective channel. We suggest a brand new method for information fusion in case of ensemble of Lipschitz classifiers. This method is called “The Weighing of Inversely as Lipschitz Constants” (WILC). Results of WILC-method practical usage in multichannel C-OTDR monitoring systems are presented.« less

  20. The start-up phase of the national satellite forest monitoring systems for DRC and PNG: a joint venture between FAO and INPE

    NASA Astrophysics Data System (ADS)

    Jonckheere, I. G.; FAO UN-REDD Team Forestry Department

    2011-12-01

    Reducing Emissions from Deforestation and Forest Degradation (REDD) is an effort to create a financial value for the carbon stored in forests, offering incentives for developing countries to reduce emissions from forested lands and invest in low-carbon paths to sustainable development. "REDD+" goes beyond deforestation and forest degradation, and includes the role of conservation, sustainable management of forests and enhancement of forest carbon stocks. In the framework of getting countries ready for REDD+, the UN-REDD Programme, a partnership between UNEP, FAO and UNDP, assists developing countries to prepare and implement national REDD+ strategies. Designed collaboratively by a broad range of stakeholders, national UN-REDD Programmes are informed by the technical expertise of FAO, UNDP and UNEP. For the monitoring, reporting and verification, FAO supports the countries to develop satellite forest monitoring systems that allow for credible measurement, reporting and verification (MRV)of REDD+ activities. These are among the most critical elements for the successful implementation of any REDD+ mechanism, also following the COP 16 decisions in Cancun last year. The UN-REDD Programme through a joint effort of FAO and Brazil's National Space Agency, INPE, is supporting countries to develop cost-effective, robust and compatible national monitoring and MRV systems, providing tools, methodologies, training and knowledge sharing that help countries to strengthen their technical and institutional capacity for effective MRV systems. To develop strong nationally-owned forest monitoring systems, technical and institutional capacity building is key. The UN-REDD Programme, through FAO, has taken on intensive training together with INPE, and has provided technical help and assistance for in-country training and implementation for national satellite forest monitoring. The goal of the start-up phase for DRC and Papua New Guinea (PNG) in this capacity building effort is the training of technical forest people and IT persons from these two interested REDD+ countries, and to set-up the national satellite forest monitoring systems. The Brazilian forest monitoring system, TerraAmazon, which is used as a basis for this initiative, allows countries to adapt it to country needs and the training on the TerraAmazon system is a tool to enhance existing capacity on carbon monitoring systems. The start-up phase of the National Forest Monitoring System for DRC and PNG will allow these countries to follow all actions related to the implementation of its national REDD+ policies and measures. The monitoring system will work as a platform to obtain information on their REDD+ results and actions, related directly or indirectly to national REDD+ strategies and may also include actions unrelated to carbon assessment, such as forest law enforcement. With the technical assistance of FAO, INPE and other stakeholders, the countries will set up an autonomous operational forest monitoring system. An initial version and the methodologies of these syste,s will be launched in Durban, South Africa during COP 17 and is presented here.

  1. Integration of structural health monitoring solutions onto commercial aircraft via the Federal Aviation Administration structural health monitoring research program

    NASA Astrophysics Data System (ADS)

    Swindell, Paul; Doyle, Jon; Roach, Dennis

    2017-02-01

    The Federal Aviation Administration (FAA) started a research program in structural health monitoring (SHM) in 2011. The program's goal was to understand the technical gaps of implementing SHM on commercial aircraft and the potential effects on FAA regulations and guidance. The program evolved into a demonstration program consisting of a team from Sandia National Labs Airworthiness Assurance NDI Center (AANC), the Boeing Corporation, Delta Air Lines, Structural Monitoring Systems (SMS), Anodyne Electronics Manufacturing Corp (AEM) and the FAA. This paper will discuss the program from the selection of the inspection problem, the SHM system (Comparative Vacuum Monitoring-CVM) that was selected as the inspection solution and the testing completed to provide sufficient data to gain the first approved use of an SHM system for routine maintenance on commercial US aircraft.

  2. A system for monitoring the radiation effects of a proton linear accelerator

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skorkin, V. M., E-mail: skorkin@inr.ru; Belyanski, K. L.; Skorkin, A. V.

    2016-12-15

    The system for real-time monitoring of radioactivity of a high-current proton linear accelerator detects secondary neutron emission from proton beam losses in transport channels and measures the activity of radionuclides in gas and aerosol emissions and the radiation background in the environment affected by a linear accelerator. The data provided by gamma, beta, and neutron detectors are transferred over a computer network to the central server. The system allows one to monitor proton beam losses, the activity of gas and aerosol emissions, and the radiation emission level of a linear accelerator in operation.

  3. Integrated monitoring technologies for the management of a Soil-Aquifer-Treatment (SAT) system.

    NASA Astrophysics Data System (ADS)

    Papadopoulos, Alexandros; Kallioras, Andreas; Kofakis, Petros; Bumberger, Jan; Schmidt, Felix; Athanasiou, Georgios; Uzunoglou, Nikolaos; Amditis, Angelos; Dietrich, Peter

    2016-04-01

    Artificial recharge of groundwater has an important role to play in water reuse as treated wastewater effluent can be infiltrated into the ground for aquifer recharge. As the effluent moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. The pilot site of Lavrion Technological & Cultural Park (LTCP) of the National Technical University of Athens (NTUA), involves the employment of plot infiltration basins at experimental scale, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. Τhe LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved by the development and installation of an integrated system of prototype sensing technologies, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time and Frequency Domain Reflectometry (TDR & FDR) sensors is developed and will be installed, in order to achieve continuous quantitative monitoring of the unsaturated zone through the entire soil column down to significant depths below the SAT basin. Additionally, the system contains two different radar-based sensing systems that will be offering (i) identification of preferential flow effects of the TDR/FDR sensors and (ii) monitoring of the water table within the shallow karst aquifer layer. The above technique will offer continuous monitoring of infiltration rates and identify possible mechanical or biological clogging effects. The monitoring system will be connected to an ad-hoc wireless network for continuous data transfer within the SAT facilities. It is envisaged that the development and combined application of all the above technologies will provide an integrated monitoring platform for the evaluation of SAT system performance.

  4. The Effect of Remote Sensor Spatial Resolution in Monitoring U.S. Army Training Maneuver Sites

    DTIC Science & Technology

    1990-12-01

    THE EFFECT OF REMOTE SENSOR SPATIAL RESOLUTION IN MONITORING U.S. ARMY...Multispectral Scanner with 6.5 meter spatial resolution provided the most effective digital data set for enhancing tank trails. However, this Airborne Scanner...primary objective of this research was to determine the capabilities and limitations of remote sensor systems having different spatial resolutions to

  5. Hemodynamic monitoring in the critically ill.

    PubMed

    Voga, G

    1995-06-01

    Monitoring of vital functions is one of the most important and essential tools in the management of critically ill patients in the ICU. Today it is possible to detect and analyze a great variety of physiological signals by various noninvasive and invasive techniques. An intensivist should be able to select and perform the most appropriate monitoring method for the individual patient considering risk-benefit ratio of the particular monitoring technique and the need for immediate therapy, specific diagnosis, continuous monitoring and evaluation of morphology should be included. Despite rapid development of noninvasive monitoring techniques, invasive hemodynamic monitoring in still one of the most basic ICU procedures. It enables monitoring of pressures, flow and saturation, pressures in the systemic and pulmonary circulation, estimation of cardiac performance and judgment of the adequacy of the cardiocirculatory system. Carefully and correctly obtained information are basis for proper hemodynamic assessment which usually effects the therapeutic decisions.

  6. Quantification of temperature effect on impedance monitoring via PZT interface for prestressed tendon anchorage

    NASA Astrophysics Data System (ADS)

    Huynh, Thanh-Canh; Kim, Jeong-Tae

    2017-12-01

    In this study, the quantification of temperature effect on impedance monitoring via a PZT interface for prestressed tendon-anchorage is presented. Firstly, a PZT interface-based impedance monitoring technique is selected to monitor impedance signatures by predetermining sensitive frequency bands. An analytical model is designed to represent coupled dynamic responses of the PZT interface-tendon anchorage system. Secondly, experiments on a lab-scaled tendon anchorage are described. Impedance signatures are measured via the PZT interface for a series of temperature and prestress-force changes. Thirdly, temperature effects on measured impedance responses of the tendon anchorage are estimated by quantifying relative changes in impedance features (such as RMSD and CCD indices) induced by temperature variation and prestress-force change. Finally, finite element analyses are conducted to investigate the mechanism of temperature variation and prestress-loss effects on the impedance responses of prestressed tendon anchorage. Temperature effects on impedance monitoring are filtered by effective frequency shift-based algorithm for distinguishing prestress-loss effects on impedance signatures.

  7. [A non-invasive portable blood-glucose monitoring system: sampling of suction effusion fluid].

    PubMed

    Arai, T; Kayashima, S; Kikuchi, M; Kaneyoshi, A; Itoh, N

    1995-04-01

    We developed a new portable transcutaneous blood glucose monitoring system using non-invasive collection of suction effusion fluid (SEF) from human skin. A ion sensitive field effect transistor (ISFET) sensor was employed to measure glucose concentration in a very small quantity of the SEF. The system was composed of a couple of portions. One structure was a suction cell, and the other was a main frame. The suction cell included the ISFET glucose sensor, a dilution mechanism, and a sucking interface to human skin. The main frame contained a dilution solution reservoir, a liquid waste reservoir, a fluid pump, a vacuum pump, a micro processor, batteries, and a user interface. The system is self-contained for portable usage during up to 6 hrs monitoring. This system may be the first blood glucose monitoring equipment which does not use blood sampling.

  8. A continuation of base-line studies for environmentally monitoring space transportation systems at John F. Kennedy Space Center. Volume 3, part 2: Ichthyological studies, sailfin molly reproduction study

    NASA Technical Reports Server (NTRS)

    Snelson, F. F., Jr.

    1980-01-01

    The applicability of monitoring populations of Poccilia latipinna (sailfin molly) and its reproductive efforts as reliable indicators of environmental effects of aerospace activities in the Kennedy Space Center area was investigated. Results show that the sailfin molly experiences drastic fluctuations in population and reproductive success and is not an appropriate factor for monitoring to establish perturbations of the environment due to space transportation system related activities.

  9. The role of 'Big Society' in monitoring the state of the natural environment.

    PubMed

    Mackechnie, Colin; Maskell, Lindsay; Norton, Lisa; Roy, David

    2011-10-01

    Environmental monitoring is essential for assessing the current state of the environment, measuring impacts of environmental pressures and providing evidence to government. Recent UK government announcements have indicated an increased role for 'Big Society' in monitoring. In this paper, we review available literature concerning the use of citizen science for monitoring, present examples of successful volunteer monitoring work and highlight important issues surrounding the use of volunteers. We argue that in order to ensure that environmental monitoring continues to be effective it is important to learn from examples where volunteers are currently used, acknowledging constraints and identifying potential approaches which will help to maximise both their engagement and data quality. Effective partnerships between environmental monitoring organisations and volunteers may thus aid the UK in developing robust coordinated monitoring systems that will be less vulnerable to funding variances.

  10. Integrated active sensor system for real time vibration monitoring.

    PubMed

    Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue

    2015-11-05

    We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0-60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems.

  11. Integrated active sensor system for real time vibration monitoring

    PubMed Central

    Liang, Qijie; Yan, Xiaoqin; Liao, Xinqin; Cao, Shiyao; Lu, Shengnan; Zheng, Xin; Zhang, Yue

    2015-01-01

    We report a self-powered, lightweight and cost-effective active sensor system for vibration monitoring with multiplexed operation based on contact electrification between sensor and detected objects. The as-fabricated sensor matrix is capable of monitoring and mapping the vibration state of large amounts of units. The monitoring contents include: on-off state, vibration frequency and vibration amplitude of each unit. The active sensor system delivers a detection range of 0–60 Hz, high accuracy (relative error below 0.42%), long-term stability (10000 cycles). On the time dimension, the sensor can provide the vibration process memory by recording the outputs of the sensor system in an extend period of time. Besides, the developed sensor system can realize detection under contact mode and non-contact mode. Its high performance is not sensitive to the shape or the conductivity of the detected object. With these features, the active sensor system has great potential in automatic control, remote operation, surveillance and security systems. PMID:26538293

  12. Hand hygiene monitoring technology: protocol for a systematic review

    PubMed Central

    2013-01-01

    Background Healthcare worker hand hygiene is thought to be one of the most important strategies to prevent healthcare-associated infections, but compliance is generally poor. Hand hygiene improvement interventions must include audits of compliance (almost always with feedback), which are most often done by direct observation - a method that is expensive, subjective, and prone to bias. New technologies, including electronic and video hand hygiene monitoring systems, have the potential to provide continuous and objective monitoring of hand hygiene, regular feedback, and for some systems, real-time reminders. We propose a systematic review of the evidence supporting the effectiveness of these systems. The primary objective is to determine whether hand hygiene monitoring systems yield sustainable improvements in hand hygiene compliance when compared to usual care. Methods/Design MEDLINE, EMBASE, CINAHL, and other relevant databases will be searched for randomized control studies and quasi-experimental studies evaluating a video or electronic hand hygiene monitoring system. A standard data collection form will be used to abstract relevant information from included studies. Bias will be assessed using the Cochrane Effective Practice and Organization of Care Group Risk of Bias Assessment Tool. Studies will be reviewed independently by two reviewers, with disputes resolved by a third reviewer. The primary outcome is directly observed hand hygiene compliance. Secondary outcomes include healthcare-associated infection incidence and improvements in hand hygiene compliance as measured by alternative metrics. Results will be qualitatively summarized with comparisons made between study quality, the measured outcome, and study-specific factors that may be expected to affect outcome (for example, study duration, frequency of feedback, use of real-time reminders). Meta-analysis will be performed if there is more than one study of similar systems with comparable outcome definitions. Discussion Electronic and video monitoring systems have the potential to improve hand hygiene compliance and prevent healthcare-associated infection, but are expensive, difficult to install and maintain, and may not be accepted by all healthcare workers. This review will assess the current evidence of effectiveness of these systems before their widespread adoption. Study registration PROSPERO registration number: CRD42013004519 PMID:24219817

  13. Hand hygiene monitoring technology: protocol for a systematic review.

    PubMed

    Srigley, Jocelyn A; Lightfoot, David; Fernie, Geoff; Gardam, Michael; Muller, Matthew P

    2013-11-12

    Healthcare worker hand hygiene is thought to be one of the most important strategies to prevent healthcare-associated infections, but compliance is generally poor. Hand hygiene improvement interventions must include audits of compliance (almost always with feedback), which are most often done by direct observation - a method that is expensive, subjective, and prone to bias. New technologies, including electronic and video hand hygiene monitoring systems, have the potential to provide continuous and objective monitoring of hand hygiene, regular feedback, and for some systems, real-time reminders. We propose a systematic review of the evidence supporting the effectiveness of these systems. The primary objective is to determine whether hand hygiene monitoring systems yield sustainable improvements in hand hygiene compliance when compared to usual care. MEDLINE, EMBASE, CINAHL, and other relevant databases will be searched for randomized control studies and quasi-experimental studies evaluating a video or electronic hand hygiene monitoring system. A standard data collection form will be used to abstract relevant information from included studies. Bias will be assessed using the Cochrane Effective Practice and Organization of Care Group Risk of Bias Assessment Tool. Studies will be reviewed independently by two reviewers, with disputes resolved by a third reviewer. The primary outcome is directly observed hand hygiene compliance. Secondary outcomes include healthcare-associated infection incidence and improvements in hand hygiene compliance as measured by alternative metrics. Results will be qualitatively summarized with comparisons made between study quality, the measured outcome, and study-specific factors that may be expected to affect outcome (for example, study duration, frequency of feedback, use of real-time reminders). Meta-analysis will be performed if there is more than one study of similar systems with comparable outcome definitions. Electronic and video monitoring systems have the potential to improve hand hygiene compliance and prevent healthcare-associated infection, but are expensive, difficult to install and maintain, and may not be accepted by all healthcare workers. This review will assess the current evidence of effectiveness of these systems before their widespread adoption. PROSPERO registration number: CRD42013004519.

  14. A Novel 3D Label-Free Monitoring System of hES-Derived Cardiomyocyte Clusters: A Step Forward to In Vitro Cardiotoxicity Testing

    PubMed Central

    Jahnke, Heinz-Georg; Steel, Daniella; Fleischer, Stephan; Seidel, Diana; Kurz, Randy; Vinz, Silvia; Dahlenborg, Kerstin; Sartipy, Peter; Robitzki, Andrea A.

    2013-01-01

    Unexpected adverse effects on the cardiovascular system remain a major challenge in the development of novel active pharmaceutical ingredients (API). To overcome the current limitations of animal-based in vitro and in vivo test systems, stem cell derived human cardiomyocyte clusters (hCMC) offer the opportunity for highly predictable pre-clinical testing. The three-dimensional structure of hCMC appears more representative of tissue milieu than traditional monolayer cell culture. However, there is a lack of long-term, real time monitoring systems for tissue-like cardiac material. To address this issue, we have developed a microcavity array (MCA)-based label-free monitoring system that eliminates the need for critical hCMC adhesion and outgrowth steps. In contrast, feasible field potential derived action potential recording is possible immediately after positioning within the microcavity. Moreover, this approach allows extended observation of adverse effects on hCMC. For the first time, we describe herein the monitoring of hCMC over 35 days while preserving the hCMC structure and electrophysiological characteristics. Furthermore, we demonstrated the sensitive detection and quantification of adverse API effects using E4031, doxorubicin, and noradrenaline directly on unaltered 3D cultures. The MCA system provides multi-parameter analysis capabilities incorporating field potential recording, impedance spectroscopy, and optical read-outs on individual clusters giving a comprehensive insight into induced cellular alterations within a complex cardiac culture over days or even weeks. PMID:23861955

  15. Online Condition Monitoring of a Rail Fastening System on High-Speed Railways Based on Wavelet Packet Analysis

    PubMed Central

    Wei, Jiahong; Liu, Chong; Ren, Tongqun; Liu, Haixia; Zhou, Wenjing

    2017-01-01

    The rail fastening system is an important part of a high-speed railway track. It is always critical to the operational safety and comfort of railway vehicles. Therefore, the condition detection of the rail fastening system, looseness or absence, is an important task in railway maintenance. However, the vision-based method cannot identify the severity of rail fastener looseness. In this paper, the condition of rail fastening system is monitored based on an automatic and remote-sensing measurement system. Meanwhile, wavelet packet analysis is used to analyze the acceleration signals, based on which two damage indices are developed to locate the damage position and evaluate the severity of rail fasteners looseness, respectively. To verify the effectiveness of the proposed method, an experiment is performed on a high-speed railway experimental platform. The experimental results show that the proposed method is effective to assess the condition of the rail fastening system. The monitoring system significantly reduces the inspection time and increases the efficiency of maintenance management. PMID:28208732

  16. Fault Injection and Monitoring Capability for a Fault-Tolerant Distributed Computation System

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo; Yates, Amy M.; Malekpour, Mahyar R.

    2010-01-01

    The Configurable Fault-Injection and Monitoring System (CFIMS) is intended for the experimental characterization of effects caused by a variety of adverse conditions on a distributed computation system running flight control applications. A product of research collaboration between NASA Langley Research Center and Old Dominion University, the CFIMS is the main research tool for generating actual fault response data with which to develop and validate analytical performance models and design methodologies for the mitigation of fault effects in distributed flight control systems. Rather than a fixed design solution, the CFIMS is a flexible system that enables the systematic exploration of the problem space and can be adapted to meet the evolving needs of the research. The CFIMS has the capabilities of system-under-test (SUT) functional stimulus generation, fault injection and state monitoring, all of which are supported by a configuration capability for setting up the system as desired for a particular experiment. This report summarizes the work accomplished so far in the development of the CFIMS concept and documents the first design realization.

  17. Shoe-Insole Technology for Injury Prevention in Walking

    PubMed Central

    Nagano, Hanatsu

    2018-01-01

    Impaired walking increases injury risk during locomotion, including falls-related acute injuries and overuse damage to lower limb joints. Gait impairments seriously restrict voluntary, habitual engagement in injury prevention activities, such as recreational walking and exercise. There is, therefore, an urgent need for technology-based interventions for gait disorders that are cost effective, willingly taken-up, and provide immediate positive effects on walking. Gait control using shoe-insoles has potential as an effective population-based intervention, and new sensor technologies will enhance the effectiveness of these devices. Shoe-insole modifications include: (i) ankle joint support for falls prevention; (ii) shock absorption by utilising lower-resilience materials at the heel; (iii) improving reaction speed by stimulating cutaneous receptors; and (iv) preserving dynamic balance via foot centre of pressure control. Using sensor technology, such as in-shoe pressure measurement and motion capture systems, gait can be precisely monitored, allowing us to visualise how shoe-insoles change walking patterns. In addition, in-shoe systems, such as pressure monitoring and inertial sensors, can be incorporated into the insole to monitor gait in real-time. Inertial sensors coupled with in-shoe foot pressure sensors and global positioning systems (GPS) could be used to monitor spatiotemporal parameters in real-time. Real-time, online data management will enable ‘big-data’ applications to everyday gait control characteristics. PMID:29738486

  18. Adverse Effects of Nonsystemic Steroids (Inhaled, Intranasal, and Cutaneous): a Review of the Literature and Suggested Monitoring Tool.

    PubMed

    Gupta, Ratika; Fonacier, Luz S

    2016-06-01

    Inhaled, intranasal, and cutaneous steroids are prescribed by physicians for a plethora of disease processes including asthma and rhinitis. While the high efficacy of this class of medication is well known, the wide range of adverse effects, both local and systemic, is not well elucidated. It is imperative to monitor total steroid burden in its varied forms as well as tracking for possible side effects that may be caused by a high cumulative dose of steroids. This review article highlights the adverse effects of different steroid modalities as well as suggests a monitoring tool to determine steroid totality and side effects.

  19. Use of multi-objective air pollution monitoring sites and online air pollution monitoring system for total health risk assessment in Hyderabad, India.

    PubMed

    Anjaneyulu, Y; Jayakumar, I; Hima Bindu, V; Sagareswar, G; Mukunda Rao, P V; Rambabu, N; Ramani, K V

    2005-08-01

    A consensus has been emerging among public health experts in developing countries that air pollution, even at current ambient levels, aggravates respiratory and cardiovascular diseases and leads to premature mortality. Recent studies have also presented well-founded theories concerning the biological mechanisms involved and the groups of people that are probably more susceptible to health effects caused or exacerbated by inhalation of ambient particulate matter (PM.). On the basis of prognostic studies carried out in Center for Environment, JNT University, Hyderabad "it has been estimated that in Hyderabad some 1,700 to 3,000 people per year die prematurely as a result of inhaling PM". These figures reflect only the effects of acute exposure to air pollution. If the long-term effects of chronic exposure are taken into account, 10,000-15,000 people a year could die prematurely in Hyderabad. This estimate of the chronic effects is based on other studies, which are not completely comparable with the Hyderabad situation. While the study designs and analyses in these other studies may indeed be different or irrelevant to Hyderabad, the fact they were carried out in other countries is irrelevant. Taking into account these considerations, a model for total health risk assessment for the city of Hyderabad, and its state of Andhra Pradesh in India has been developed using a multi-objective air pollution monitoring network and online and real time air pollution monitoring stations. For the model studies a number of potential monitoring sites were screened for general and site-specific criteria in a geographic information system (GIS) environment that may, on a local basis, affect the representativeness of the data collected. Local features that may affect either the chemical or meteorological parameters are evaluated to assure a minimum of interference. Finally, for monitoring air pollution, an online and real-time monitoring system was designed using advanced electrochemical sensor systems (sulphur dioxide, oxides of nitrogen, carbon monoxide, hydrocarbons, ozone, mercaptans and hydrogen sulphide) and a particulate matter analyzer (total suspended particulate matter TSPM), PM2.5 and PM10). The sensor and data acquisition systems are programmed to monitor pollution levels at 1/2 hour durations during peak hours and at 1-hour intervals at other times. Presently, extensive statistical and numerical simulations are being carried out at our center to correlate the individuals living in the monitored areas with respiratory infections with air pollution.

  20. Use of Multi-Objective Air Pollution Monitoring Sites and Online Air Pollution Monitoring System for Total Health Risk Assessment in Hyderabad, India

    PubMed Central

    Anjaneyulu, Y.; Jayakumar, I.; Bindu, V. Hima; Sagareswar, G.; Rao, P.V. Mukunda; Rambabu, N.; Ramani, K. V.

    2005-01-01

    A consensus has been emerging among public health experts in developing countries that air pollution, even at current ambient levels, aggravates respiratory and cardiovascular diseases and leads to premature mortality. Recent studies have also presented well-founded theories concerning the biological mechanisms involved and the groups of people that are probably more susceptible to health effects caused or exacerbated by inhalation of ambient particulate matter (PM.). On the basis of prognostic studies carried out in Center for Environment, JNT University, Hyderabad “it has been estimated that in Hyderabad some 1,700 to 3,000 people per year die prematurely as a result of inhaling PM”. These figures reflect only the effects of acute exposure to air pollution. If the long-term effects of chronic exposure are taken into account, 10,000–15,000 people a year could die prematurely in Hyderabad. This estimate of the chronic effects is based on other studies, which are not completely comparable with the Hyderabad situation. While the study designs and analyses in these other studies may indeed be different or irrelevant to Hyderabad, the fact they were carried out in other countries is irrelevant. Taking into account these considerations, a model for total health risk assessment for the city of Hyderabad, and its state of Andhra Pradesh in India has been developed using a multi-objective air pollution monitoring network and online and real time air pollution monitoring stations. For the model studies a number of potential monitoring sites were screened for general and site-specific criteria in a geographic information system (GIS) environment that may, on a local basis, affect the representativeness of the data collected. Local features that may affect either the chemical or meteorological parameters are evaluated to assure a minimum of interference. Finally, for monitoring air pollution, an online and real-time monitoring system was designed using advanced electrochemical sensor systems (sulphur dioxide, oxides of nitrogen, carbon monoxide, hydrocarbons, ozone, mercaptans and hydrogen sulphide) and a particulate matter analyzer (total suspended particulate matter TSPM), PM2.5 and PM10). The sensor and data acquisition systems are programmed to monitor pollution levels at ½ hour durations during peak hours and at 1-hour intervals at other times. Presently, extensive statistical and numerical simulations are being carried out at our center to correlate the individuals living in the monitored areas with respiratory infections with air pollution. PMID:16705838

  1. 47 CFR 73.1690 - Modification of transmission systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... antenna system. See § 73.45 and § 73.150. (5) Any decrease in the authorized power of an AM station or the... station is located in or near a radio quiet zone, radio coordination zone, or a Commission monitoring... Information Bureau in the case of a monitoring station, to increase effective radiated power PRIOR to...

  2. [Application of classified protection of information security in the information system of air pollution and health impact monitoring].

    PubMed

    Hao, Shuxin; Lü, Yiran; Liu, Jie; Liu, Yue; Xu, Dongqun

    2018-01-01

    To study the application of classified protection of information security in the information system of air pollution and health impact monitoring, so as to solve the possible safety risk of the information system. According to the relevant national standards and requirements for the information system security classified protection, and the professional characteristics of the information system, to design and implement the security architecture of information system, also to determine the protection level of information system. Basic security measures for the information system were developed in the technical safety and management safety aspects according to the protection levels, which effectively prevented the security risk of the information system. The information system established relatively complete information security protection measures, to enhanced the security of professional information and system service, and to ensure the safety of air pollution and health impact monitoring project carried out smoothly.

  3. FREQUENCY DISTRIBUTIONS AND SPATIAL ANALYSIS OF FINE PARTICLE MEASUREMENTS IN ST. LOUIS DURING THE REGIONAL AIR POLLUTION STUDY/REGIONAL AIR MONITORING SYSTEM

    EPA Science Inventory

    Community, time-series epidemiology typically uses either 24-hour integrated particulate matter (PM) concentrations averaged across several monitors in a city or data obtained at a central monitoring site to relate PM concentrations to human health effects. If 24-hour integrated...

  4. FFI: A software tool for ecological monitoring

    Treesearch

    Duncan C. Lutes; Nathan C. Benson; MaryBeth Keifer; John F. Caratti; S. Austin Streetman

    2009-01-01

    A new monitoring tool called FFI (FEAT/FIREMON Integrated) has been developed to assist managers with collection, storage and analysis of ecological information. The tool was developed through the complementary integration of two fire effects monitoring systems commonly used in the United States: FIREMON and the Fire Ecology Assessment Tool. FFI provides software...

  5. Simultaneous acoustic and dielectric real time curing monitoring of epoxy systems

    NASA Astrophysics Data System (ADS)

    Gkikas, G.; Saganas, Ch.; Grammatikos, S. A.; Aggelis, D. G.; Paipetis, A. S.

    2012-04-01

    The attainment of structural integrity of the reinforcing matrix in composite materials is of primary importance for the final properties of the composite structure. The detailed monitoring of the curing process on the other hand is paramount (i) in defining the optimal conditions for the impregnation of the reinforcement by the matrix (ii) in limiting the effects of the exotherm produced by the polymerization reaction which create unwanted thermal stresses and (iii) in securing optimal behavior in matrix controlled properties, such as off axis or shear properties and in general the durability of the composite. Dielectric curing monitoring is a well known technique for distinguishing between the different stages of the polymerization of a typical epoxy system. The technique successfully predicts the gelation and the vitrification of the epoxy and has been extended for the monitoring of prepregs. Recent work has shown that distinct changes in the properties of the propagated sound in the epoxy which undergoes polymerization is as well directly related to the gelation and vitrification of the resin, as well as to the attainment of the final properties of the resin system. In this work, a typical epoxy is simultaneously monitored using acoustic and dielectric methods. The system is isothermally cured in an oven to avoid effects from the polymerization exotherm. Typical broadband sensors are employed for the acoustic monitoring, while flat interdigital sensors are employed for the dielectric scans. All stages of the polymerization process were successfully monitored and the validity of both methods was cross checked and verified.

  6. Novel diffuse optics system for continuous tissue viability monitoring: extended recovery in vivo testing in a porcine flap model

    NASA Astrophysics Data System (ADS)

    Lee, Seung Yup; Pakela, Julia M.; Hedrick, Taylor L.; Vishwanath, Karthik; Helton, Michael C.; Chung, Yooree; Kolodziejski, Noah J.; Stapels, Christopher J.; McAdams, Daniel R.; Fernandez, Daniel E.; Christian, James F.; O'Reilly, Jameson; Farkas, Dana; Ward, Brent B.; Feinberg, Stephen E.; Mycek, Mary-Ann

    2017-02-01

    In reconstructive surgery, tissue perfusion/vessel patency is critical to the success of microvascular free tissue flaps. Early detection of flap failure secondary to compromise of vascular perfusion would significantly increase the chances of flap salvage. We have developed a compact, clinically-compatible monitoring system to enable automated, minimally-invasive, continuous, and quantitative assessment of flap viability/perfusion. We tested the system's continuous monitoring capability during extended non-recovery surgery using an in vivo porcine free flap model. Initial results indicated that the system could assess flap viability/perfusion in a quantitative and continuous manner. With proven performance, the compact form constructed with cost-effective components would make this system suitable for clinical translation.

  7. Advanced active health monitoring system of liquid rocket engines

    NASA Astrophysics Data System (ADS)

    Qing, Xinlin P.; Wu, Zhanjun; Beard, Shawn; Chang, Fu-Kuo

    2008-11-01

    An advanced SMART TAPE system has been developed for real-time in-situ monitoring and long term tracking of structural integrity of pressure vessels in liquid rocket engines. The practical implementation of the structural health monitoring (SHM) system including distributed sensor network, portable diagnostic hardware and dedicated data analysis software is addressed based on the harsh operating environment. Extensive tests were conducted on a simulated large booster LOX-H2 engine propellant duct to evaluate the survivability and functionality of the system under the operating conditions of typical liquid rocket engines such as cryogenic temperature, vibration loads. The test results demonstrated that the developed SHM system could survive the combined cryogenic temperature and vibration environments and effectively detect cracks as small as 2 mm.

  8. Measurement of greenhouse gases in UAE by using Unmanned Aerial Vehicle (UAV)

    NASA Astrophysics Data System (ADS)

    Abou-Elnour, Ali; Odeh, Mohamed; Abdelrhman, Mohammed; Balkis, Ahmed; Amira, Abdelraouf

    2017-04-01

    In the present work, a reliable and low cost system has been designed and implemented to measure greenhouse gases (GHG) in United Arab Emirates (UAE) by using unmanned aerial vehicle (UAV). A set of accurate gas, temperature, pressure, humidity sensors are integrated together with a wireless communication system on a microcontroller based platform to continuously measure the required data. The system instantaneously sends the measured data to a center monitoring unit via the wireless communication system. In addition, the proposed system has the features that all measurements are recorded directly in a storage device to allow effective monitoring in regions with weak or no wireless coverage. The obtained data will be used in all further sophisticated calculations for environmental research and monitoring purposes.

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, T; Kim, D; Kang, S

    Purpose: Abdominal compression is known to be effective but, often makes external-marker-based monitoring of breathing motion not feasible. In this study, we developed and evaluated a system that enables both abdominal compression and monitoring of residual abdominal motion simultaneously. The system can also provide visual-biofeedback capability. Methods: The system developed consists of a compression belt, an abdominal motion monitoring sensor (gas pressure sensor) and a visual biofeedback device. The compression belt was designed to be able to compress the frontal side of the abdomen. The pressure level of the belt is controlled by air volume and monitored in real timemore » using the gas pressure sensor. The system displays not only the real-time monitoring curve but also a guiding respiration model (e.g., a breath hold or shallow breathing curve) simultaneously on the head mounted display to help patients keep their breathing pattern as consistent as possible. Three healthy volunteers were enrolled in this pilot study and respiratory signals (pressure variations) were obtained both with and without effective abdominal compression to investigate the feasibility of the developed system. Two guidance patterns, breath hold and shallow breathing, were tested. Results: All volunteers showed smaller abdominal motion with compression (about 40% amplitude reduction compared to without compression). However, the system was able to monitor residual abdominal motion for all volunteers. Even under abdominal compression, in addition, it was possible to make the subjects successfully follow the guide patterns using the visual biofeedback system. Conclusion: The developed abdominal compression & respiratory guiding system was feasible for residual abdominal motion management. It is considered that the system can be used for a respiratory motion involved radiation therapy while maintaining the merit of abdominal compression. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less

  10. Post-marketing health technology monitoring. The analysis of an experience from a clinical perspective.

    PubMed

    Ibargoyen-Roteta, Nora; Cabriada-Nuño, Jose Luis; Gutiérrez-Ibarluzea, Iñaki; Hernández-Ramírez, Vicent; Clofent-Vilaplana, Juan; Domènech-Morral, Eugeni; Ginard-Vicens, Daniel; Oliva-Oliva, Gloria; Queiro-Verdes, Teresa

    2011-01-01

    A system for monitoring the use of aphaeresis in the treatment of ulcerative colitis (UC), named system for monitoring aphaeresis in ulcerative colitis (SiMAC), was designed in 2006 in the Basque Country. In the present study, the opinion of the clinicians who participated in SiMAC was evaluated, in order to identify the barriers and gather suggestions that could improve implementation of this kind of system. A mixed questionnaire was designed, in order to gather clinicians' assessments of the SiMAC monitoring system. The response rate was 73.9% (17/23). The data from 40.96% (159/388) of patients with UC treated with aphaeresis was recorded. The main reasons for not including the data from all treated patients were a lack of required data or not meeting the study inclusion criteria. Positive aspects of the SiMAC were identified, as the simplicity of data collection and its systematic, multi-center approach. The negative aspects mentioned were the use of a local computer application and the lack of time for health professionals to enter data. The use of monitoring systems helps to formalize the introduction of technologies of little-known effectiveness; involve clinicians and medical societies in coming to agreement and obtaining information about the safety, effectiveness or efficiency of new technologies; and provide relevant information to healthcare administrations for making decisions about the introduction of new technologies into healthcare practice. In order for a monitoring system to work, the process must be straightforward. A minimum set of key variables that are easy to collect must be selected, and an effort made to involve a range of stakeholders, especially institutions and scientific societies, to support the work group.

  11. Patient-Centered Technological Assessment and Monitoring of Depression for Low-Income Patients

    PubMed Central

    Wu, Shinyi; Vidyanti, Irene; Liu, Pai; Hawkins, Caitlin; Ramirez, Magaly; Guterman, Jeffrey; Gross-Schulman, Sandra; Sklaroff, Laura Myerchin; Ell, Kathleen

    2014-01-01

    Depression is a significant challenge for ambulatory care because it worsens health status and outcomes, increases health care utilizations and costs, and elevates suicide risk. An automatic telephonic assessment (ATA) system that links with tasks and alerts to providers may improve quality of depression care and increase provider productivity. We used ATA system in a trial to assess and monitor depressive symptoms of 444 safety-net primary care patients with diabetes. We assessed system properties, evaluated preliminary clinical outcomes, and estimated cost savings. The ATA system is feasible, reliable, valid, safe, and likely cost-effective for depression screening and monitoring for low-income primary care population. PMID:24525531

  12. Monitoring of subsurface injection of wastes, Florida

    USGS Publications Warehouse

    Vecchioli, John

    1979-01-01

    Injection of waste liquids into Florida's subsurface is physically feasible in many places but should be accompanied by monitoring of the waste-receiving aquifer system in addition to the injection facility. Monitoring of the interaction of factors including hydrogeologic conditions, well construction, waste volumes and characteristics, and potable-water sources is desirable to assure that fresh-water resources are not being adversely affected. An effective aquifer-system monitoring program includes on-site wells located close to an injection well and open to the next-higher permeable stratum, satellite wells located hundreds to several thousands of feet from an injection well and open to the receiving aquifer, and regional wells located miles from individual injection wells and open to the receiving aquifer. An extensive aquifer-system monitoring program associated with two waste-injection facilities near Pensacola, Florida, has provided data which have aided hydrologists to understand the aquifer system's response to the injection and, accordingly, to evaluate the potential for affecting the area's fresh-water resources.

  13. Short-term effects of benzalkonium chloride and atrazine on Elodea canadensis using a miniaturised microbioreactor system for an online monitoring of physiologic parameters.

    PubMed

    Vervliet-Scheebaum, Marco; Ritzenthaler, Raphael; Normann, Johannes; Wagner, Edgar

    2008-02-01

    The study evaluated the effects of benzalkonium chloride (BAC) and atrazine on the macrophyte Elodea canadensis (Michaux) using a miniaturised monitoring test system consisting of a microbioreactor of reduced volume and integrated sensors for the online measurement of physiologic parameters, like oxygen production and different parameters of fluorescence. Different concentrations of both chemicals were applied to leaves of E. canadensis and the physiologic endpoints evaluated after 1h. A concentration-dependent reduction of the oxygen production and of the effective quantum yield of energy conversion was recorded. The mini-PAM technique implemented in the presented system allowed for a clear monitoring of the kinetic of BAC and atrazine, showing their distinct mode of action. No observable adverse effects were recorded up to concentrations of 2.5 mg/L and 10 microg/L, for BAC and atrazine, respectively. These values are in accordance with available results in the literature, hence indicating that the microbioreactor test system might be suitable, on the one hand, for the laboratory screening of potential short-term toxicity of contaminants on aquatic plants, and on the other hand, serve as an in situ field biomonitoring system for the rapid detection of pollutants in water.

  14. A head-mounted display-based personal integrated-image monitoring system for transurethral resection of the prostate.

    PubMed

    Yoshida, Soichiro; Kihara, Kazunori; Takeshita, Hideki; Fujii, Yasuhisa

    2014-12-01

    The head-mounted display (HMD) is a new image monitoring system. We developed the Personal Integrated-image Monitoring System (PIM System) using the HMD (HMZ-T2, Sony Corporation, Tokyo, Japan) in combination with video splitters and multiplexers as a surgical guide system for transurethral resection of the prostate (TURP). The imaging information obtained from the cystoscope, the transurethral ultrasonography (TRUS), the video camera attached to the HMD, and the patient's vital signs monitor were split and integrated by the PIM System and a composite image was displayed by the HMD using a four-split screen technique. Wearing the HMD, the lead surgeon and the assistant could simultaneously and continuously monitor the same information displayed by the HMD in an ergonomically efficient posture. Each participant could independently rearrange the images comprising the composite image depending on the engaging step. Two benign prostatic hyperplasia (BPH) patients underwent TURP performed by surgeons guided with this system. In both cases, the TURP procedure was successfully performed, and their postoperative clinical courses had no remarkable unfavorable events. During the procedure, none of the participants experienced any HMD-wear related adverse effects or reported any discomfort.

  15. Detecting Bioterrorism: Is Chemistry Enough?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Omberg, Kristin M.

    2014-03-13

    This slide shows how most bioaerosol detection systems work. There is a lot of concern in the biothreat community, and in the federal government, about a large-scale aerosolized attack. Because of that, we’ve implemented environmental monitoring programs that use aerosol collectors to continuously monitor for the presence of threat agents in the air. Air samples are usually analyzed using PCR, which is one of the most effective analytical techniques we have for identifying DNA. Experiments and modeling have shown these systems are effective, and can warn public health of an impending crisis in time to mount an effective response.

  16. Why and how to monitor the cost and evaluate the cost-effectiveness of HIV services in countries.

    PubMed

    Beck, Eduard J; Santas, Xenophon M; Delay, Paul R

    2008-07-01

    The number of people in the world living with HIV is increasing as HIV-related mortality has declined but the annual number of people newly infected with HIV has not. The international response to contain the HIV pandemic, meanwhile, has grown. Since 2006, an international commitment to scale up prevention, treatment, care and support services in middle and lower-income countries by 2010 has been part of the Universal Access programme, which itself plays an important part in achieving the Millennium Development Goals by 2015. Apart from providing technical support, donor countries and agencies have substantially increased their funding to enable countries to scale up HIV services. Many countries have been developing their HIV monitoring and evaluation systems to generate the strategic information required to track their response and ensure the best use of the new funds. Financial information is an important aspect of the strategic information required for scaling up existing services as well as assessing the effect of new ones. It involves two components: tracking the money available and spent on HIV at all levels, through budget tracking, national health accounts and national AIDS spending assessments, and estimating the cost and efficiency of HIV services. The cost of service provision should be monitored over time, whereas evaluations of the cost-effectiveness of services are required periodically; both should be part of any country's HIV monitoring and evaluation system. This paper provides country examples of the complementary relationship between monitoring the cost of HIV services and evaluating their cost-effectiveness. It also summarizes global initiatives that enable countries to develop their own HIV monitoring and evaluation systems and to generate relevant, robust and up-to-date strategic information.

  17. Is the soil quality monitoring an effective tool in consumers' protection of agricultural crops from cadmium soil contamination?-a case of the Silesia region (Poland).

    PubMed

    Piekut, Agata; Baranowska, Renata; Marchwińska-Wyrwał, Ewa; Ćwieląg-Drabek, Małgorzata; Hajok, Ilona; Dziubanek, Grzegorz; Grochowska-Niedworok, Elżbieta

    2017-12-16

    The monitoring of soil quality should be a control tool used to reduce the adverse health effects arising from exposure to toxic chemicals in soil through cultivated crop absorption. The aim of the study was to evaluate the effectiveness of the monitoring and control system of soil quality in Poland, in terms of consumer safety, for agricultural plants cultivated in areas with known serious cadmium contamination, such as Silesia Province. To achieve the objective, the contents of cadmium in soils and vegetables in the Silesia administrative area were examined. The obtained results were compared with the results of soil contamination from the quality monitoring of arable soil in Poland. The studies show a significant exceedance of the permissible values of cadmium in soil samples and the vegetables cultivated on that soil. The threat to consumer health is a valid concern, although this threat was not indicated by the results of the national monitoring of soil quality. The results indicated an unequal distribution of risk to consumers resulting from contaminated soil. Moreover, the monitoring systems should be designed at the local or regional scale to guarantee the safety of consumers of edible plants cultivated in the areas contaminated with cadmium.

  18. Assessment of SRS ambient air monitoring network

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbott, K.; Jannik, T.

    Three methodologies have been used to assess the effectiveness of the existing ambient air monitoring system in place at the Savannah River Site in Aiken, SC. Effectiveness was measured using two metrics that have been utilized in previous quantification of air-monitoring network performance; frequency of detection (a measurement of how frequently a minimum number of samplers within the network detect an event), and network intensity (a measurement of how consistent each sampler within the network is at detecting events). In addition to determining the effectiveness of the current system, the objective of performing this assessment was to determine what, ifmore » any, changes could make the system more effective. Methodologies included 1) the Waite method of determining sampler distribution, 2) the CAP88- PC annual dose model, and 3) a puff/plume transport model used to predict air concentrations at sampler locations. Data collected from air samplers at SRS in 2015 compared with predicted data resulting from the methodologies determined that the frequency of detection for the current system is 79.2% with sampler efficiencies ranging from 5% to 45%, and a mean network intensity of 21.5%. One of the air monitoring stations had an efficiency of less than 10%, and detected releases during just one sampling period of the entire year, adding little to the overall network intensity. By moving or removing this sampler, the mean network intensity increased to about 23%. Further work in increasing the network intensity and simulating accident scenarios to further test the ambient air system at SRS is planned« less

  19. Smartphone-based Continuous Blood Pressure Measurement Using Pulse Transit Time.

    PubMed

    Gholamhosseini, Hamid; Meintjes, Andries; Baig, Mirza; Linden, Maria

    2016-01-01

    The increasing availability of low cost and easy to use personalized medical monitoring devices has opened the door for new and innovative methods of health monitoring to emerge. Cuff-less and continuous methods of measuring blood pressure are particularly attractive as blood pressure is one of the most important measurements of long term cardiovascular health. Current methods of noninvasive blood pressure measurement are based on inflation and deflation of a cuff with some effects on arteries where blood pressure is being measured. This inflation can also cause patient discomfort and alter the measurement results. In this work, a mobile application was developed to collate the PhotoPlethysmoGramm (PPG) waveform provided by a pulse oximeter and the electrocardiogram (ECG) for calculating the pulse transit time. This information is then indirectly related to the user's systolic blood pressure. The developed application successfully connects to the PPG and ECG monitoring devices using Bluetooth wireless connection and stores the data onto an online server. The pulse transit time is estimated in real time and the user's systolic blood pressure can be estimated after the system has been calibrated. The synchronization between the two devices was found to pose a challenge to this method of continuous blood pressure monitoring. However, the implemented continuous blood pressure monitoring system effectively serves as a proof of concept. This combined with the massive benefits that an accurate and robust continuous blood pressure monitoring system would provide indicates that it is certainly worthwhile to further develop this system.

  20. Measuring sports injuries on the pitch: a guide to use in practice

    PubMed Central

    Hespanhol, Luiz C.; Barboza, Saulo D.; van Mechelen, Willem; Verhagen, Evert

    2015-01-01

    Sports participation is a major ally for the promotion of physical activity. However, sports injuries are important adverse effects of sports participation and should be monitored in sports populations. The purpose of this paper is to review the basic concepts of injury monitoring and discuss the implementation of these concepts in practice. The aspects discussed are: (1) sports injury definition; (2) classification of sports injuries; (3) population at risk, prevalence, and incidence; (4) severity measures; (5) economic costs; (6) systems developed to monitor sports injuries; and (7) online technology. Only with reliable monitoring systems applied in a continuous and long-term manner will it be possible to identify the burden of injuries, to identify the possible cases at an early stage, to implement early interventions, and to generate data for sports injury prevention. The implementation of sports injuries monitoring systems in practice is strongly recommended. PMID:26537807

  1. Utilizing a Homecare Platform for Remote Monitoring of Patients with Idiopathic Pulmonary Fibrosis.

    PubMed

    Panagopoulos, Christos; Malli, Foteini; Menychtas, Andreas; Smyrli, Efstathia-Petrina; Georgountzou, Aikaterini; Daniil, Zoe; Gourgoulianis, Konstantinos I; Tsanakas, Panayiotis; Maglogiannis, Ilias

    2017-01-01

    Homecare and home telemonitoring are a focal point of emerging healthcare schemes, with proven benefits for both patients, caregivers and providers, including reduction of healthcare costs and improved patients' quality of life, especially in the case of chronic disease management. Studies have evaluated solutions for remote monitoring of chronic patients based on technologies that allow daily symptom and vital signs monitoring, tailored to the needs of specific diseases. In this work, we present an affordable home telemonitoring system for patients with idiopathic pulmonary fibrosis (IPF), based on an application for mobile devices and Bluetooth-enabled sensors for pulse oximetry and blood pressure measurements. Besides monitoring of vital signs, the system incorporates communication via videoconferencing and emergency response, with support from a helpdesk service. A pilot study was conducted, in order to verify the proposed solution's feasibility. The results support the utilization of the system for effective monitoring of patients with IPF.

  2. Combined Use of a Patient Dose Monitoring System and a Real-Time Occupational Dose Monitoring System for Fluoroscopically Guided Interventions.

    PubMed

    Heilmaier, Christina; Kara, Levent; Zuber, Niklaus; Berthold, Christian; Weishaupt, Dominik

    2016-04-01

    To determine the effect on patient radiation exposure of the combined use of a patient dose monitoring system and real-time occupational dose monitoring during fluoroscopically guided interventions (FGIs). Patient radiation exposure, in terms of the kerma area product (KAP; Gy ∙ cm(2)), was measured in period 1 with a patient dose monitoring system, and a real-time occupational dose monitoring system was additionally applied in period 2. Mean/median KAP in 19 different types of FGIs was analyzed in both periods for two experienced interventional radiologists combined as well as individually. Patient dose and occupational dose were correlated, applying Pearson and Spearman correlation coefficients. Although FGIs were similar in numbers and types over both periods, a substantial decrease was found for period 2 in total mean ± SD/median KAP for both operators together (period 1, 47 Gy ∙ cm(2) ± 67/41 Gy ∙ cm(2); period 2, 37 Gy ∙ cm(2) ± 69/34 Gy ∙ cm(2)) as well as for each individual operator (for all, P < .05). Overall, KAP declined considerably in 15 of 19 types of FGIs in period 2. Mean accumulated dose per intervention was 4.6 µSv, and mean dose rate was 0.24 mSv/h. There was a strong positive correlation between patient and occupational dose (r = 0.88). Combined use of a patient dose monitoring system and a real-time occupational dose monitoring system in FGIs significantly lessens patient and operator doses. Copyright © 2016 SIR. Published by Elsevier Inc. All rights reserved.

  3. Effective HTCondor-based monitoring system for CMS

    NASA Astrophysics Data System (ADS)

    Balcas, J.; Bockelman, B. P.; Da Silva, J. M.; Hernandez, J.; Khan, F. A.; Letts, J.; Mascheroni, M.; Mason, D. A.; Perez-Calero Yzquierdo, A.; Vlimant, J.-R.; pre="for the"> CMS Consortium,

    2017-10-01

    The CMS experiment at the LHC relies on HTCondor and glideinWMS as its primary batch and pilot-based Grid provisioning systems, respectively. Given the scale of the global queue in CMS, the operators found it increasingly difficult to monitor the pool to find problems and fix them. The operators had to rely on several different web pages, with several different levels of information, and sift tirelessly through log files in order to monitor the pool completely. Therefore, coming up with a suitable monitoring system was one of the crucial items before the beginning of the LHC Run 2 in order to ensure early detection of issues and to give a good overview of the whole pool. Our new monitoring page utilizes the HTCondor ClassAd information to provide a complete picture of the whole submission infrastructure in CMS. The monitoring page includes useful information from HTCondor schedulers, central managers, the glideinWMS frontend, and factories. It also incorporates information about users and tasks making it easy for operators to provide support and debug issues.

  4. Smart Sensing Strip Using Monolithically Integrated Flexible Flow Sensor for Noninvasively Monitoring Respiratory Flow

    PubMed Central

    Jiang, Peng; Zhao, Shuai; Zhu, Rong

    2015-01-01

    This paper presents a smart sensing strip for noninvasively monitoring respiratory flow in real time. The monitoring system comprises a monolithically-integrated flexible hot-film flow sensor adhered on a molded flexible silicone case, where a miniaturized conditioning circuit with a Bluetooth4.0 LE module are packaged, and a personal mobile device that wirelessly acquires respiratory data transmitted from the flow sensor, executes extraction of vital signs, and performs medical diagnosis. The system serves as a wearable device to monitor comprehensive respiratory flow while avoiding use of uncomfortable nasal cannula. The respiratory sensor is a flexible flow sensor monolithically integrating four elements of a Wheatstone bridge on single chip, including a hot-film resistor, a temperature-compensating resistor, and two balancing resistors. The monitor takes merits of small size, light weight, easy operation, and low power consumption. Experiments were conducted to verify the feasibility and effectiveness of monitoring and diagnosing respiratory diseases using the proposed system. PMID:26694401

  5. Smart fiber-reinforced polymer anchorage system with optical fiber Bragg grating sensors

    NASA Astrophysics Data System (ADS)

    Huang, Minghua; Zhou, Zhi; He, Jianping; Chen, Genda; Ou, Jinping

    2010-03-01

    Civil Engineers have used fiber reinforced polymer (FRP) with high axial strength as an effective and economical alternative to steel in harsh corrosion environments. However, the practical applications of FRP are limited by the tendency of FRP materials to fail suddenly under lateral pressure and surface injury. For example, shear stresses result from the bonding effect between the FRP material and the structure of the anchorage system due to the lower shear strength of FRP. This paper proposes a novel smart FRP anchorage system with embedded optical fiber Bragg grating (FBG) sensors to monitor the axial strain state and accordingly the interfacial shear stress, as well as the interfacial damage characteristics of FRP anchorage. One FBG sensor was embedded in an FRP rod outside the anchorage region to evaluate the properties of the material, and seven FBG sensors were distributed along the rod in the anchor to monitor the axial strain variations and study the interfacial mechanical behaviors of the smart FRP anchorage under a static pulling load. The experimental results agreed well with theoretical predictions. The smart FRP anchorage system with optical FBG sensors proves effective and practical for monitoring the long-term mechanical behavior of FRP anchorage systems.

  6. Development and Application of a Structural Health Monitoring System Based on Wireless Smart Aggregates

    PubMed Central

    Ma, Haoyan; Li, Peng; Song, Gangbing; Wu, Jianxin

    2017-01-01

    Structural health monitoring (SHM) systems can improve the safety and reliability of structures, reduce maintenance costs, and extend service life. Research on concrete SHMs using piezoelectric-based smart aggregates have reached great achievements. However, the newly developed techniques have not been widely applied in practical engineering, largely due to the wiring problems associated with large-scale structural health monitoring. The cumbersome wiring requires much material and labor work, and more importantly, the associated maintenance work is also very heavy. Targeting a practical large scale concrete crack detection (CCD) application, a smart aggregates-based wireless sensor network system is proposed for the CCD application. The developed CCD system uses Zigbee 802.15.4 protocols, and is able to perform dynamic stress monitoring, structural impact capturing, and internal crack detection. The system has been experimentally validated, and the experimental results demonstrated the effectiveness of the proposed system. This work provides important support for practical CCD applications using wireless smart aggregates. PMID:28714927

  7. Development and Application of a Structural Health Monitoring System Based on Wireless Smart Aggregates.

    PubMed

    Yan, Shi; Ma, Haoyan; Li, Peng; Song, Gangbing; Wu, Jianxin

    2017-07-17

    Structural health monitoring (SHM) systems can improve the safety and reliability of structures, reduce maintenance costs, and extend service life. Research on concrete SHMs using piezoelectric-based smart aggregates have reached great achievements. However, the newly developed techniques have not been widely applied in practical engineering, largely due to the wiring problems associated with large-scale structural health monitoring. The cumbersome wiring requires much material and labor work, and more importantly, the associated maintenance work is also very heavy. Targeting a practical large scale concrete crack detection (CCD) application, a smart aggregates-based wireless sensor network system is proposed for the CCD application. The developed CCD system uses Zigbee 802.15.4 protocols, and is able to perform dynamic stress monitoring, structural impact capturing, and internal crack detection. The system has been experimentally validated, and the experimental results demonstrated the effectiveness of the proposed system. This work provides important support for practical CCD applications using wireless smart aggregates.

  8. CSHM: Web-based safety and health monitoring system for construction management.

    PubMed

    Cheung, Sai On; Cheung, Kevin K W; Suen, Henry C H

    2004-01-01

    This paper describes a web-based system for monitoring and assessing construction safety and health performance, entitled the Construction Safety and Health Monitoring (CSHM) system. The design and development of CSHM is an integration of internet and database systems, with the intent to create a total automated safety and health management tool. A list of safety and health performance parameters was devised for the management of safety and health in construction. A conceptual framework of the four key components of CSHM is presented: (a) Web-based Interface (templates); (b) Knowledge Base; (c) Output Data; and (d) Benchmark Group. The combined effect of these components results in a system that enables speedy performance assessment of safety and health activities on construction sites. With the CSHM's built-in functions, important management decisions can theoretically be made and corrective actions can be taken before potential hazards turn into fatal or injurious occupational accidents. As such, the CSHM system will accelerate the monitoring and assessing of performance safety and health management tasks.

  9. Development of a fully automated network system for long-term health-care monitoring at home.

    PubMed

    Motoi, K; Kubota, S; Ikarashi, A; Nogawa, M; Tanaka, S; Nemoto, T; Yamakoshi, K

    2007-01-01

    Daily monitoring of health condition at home is very important not only as an effective scheme for early diagnosis and treatment of cardiovascular and other diseases, but also for prevention and control of such diseases. From this point of view, we have developed a prototype room for fully automated monitoring of various vital signs. From the results of preliminary experiments using this room, it was confirmed that (1) ECG and respiration during bathing, (2) excretion weight and blood pressure, and (3) respiration and cardiac beat during sleep could be monitored with reasonable accuracy by the sensor system installed in bathtub, toilet and bed, respectively.

  10. Wireless and Powerless Sensing Node System Developed for Monitoring Motors.

    PubMed

    Lee, Dasheng

    2008-08-27

    Reliability and maintainability of tooling systems can be improved through condition monitoring of motors. However, it is difficult to deploy sensor nodes due to the harsh environment of industrial plants. Sensor cables are easily damaged, which renders the monitoring system deployed to assure the machine's reliability itself unreliable. A wireless and powerless sensing node integrated with a MEMS (Micro Electro-Mechanical System) sensor, a signal processor, a communication module, and a self-powered generator was developed in this study for implementation of an easily mounted network sensor for monitoring motors. A specially designed communication module transmits a sequence of electromagnetic (EM) pulses in response to the sensor signals. The EM pulses can penetrate through the machine's metal case and delivers signals from the sensor inside the motor to the external data acquisition center. By using induction power, which is generated by the motor's shaft rotation, the sensor node is self-sustaining; therefore, no power line is required. A monitoring system, equipped with novel sensing nodes, was constructed to test its performance. The test results illustrate that, the novel sensing node developed in this study can effectively enhance the reliability of the motor monitoring system and it is expected to be a valuable technology, which will be available to the plant for implementation in a reliable motor management program.

  11. Wireless and Powerless Sensing Node System Developed for Monitoring Motors

    PubMed Central

    Lee, Dasheng

    2008-01-01

    Reliability and maintainability of tooling systems can be improved through condition monitoring of motors. However, it is difficult to deploy sensor nodes due to the harsh environment of industrial plants. Sensor cables are easily damaged, which renders the monitoring system deployed to assure the machine's reliability itself unreliable. A wireless and powerless sensing node integrated with a MEMS (Micro Electro-Mechanical System) sensor, a signal processor, a communication module, and a self-powered generator was developed in this study for implementation of an easily mounted network sensor for monitoring motors. A specially designed communication module transmits a sequence of electromagnetic (EM) pulses in response to the sensor signals. The EM pulses can penetrate through the machine's metal case and delivers signals from the sensor inside the motor to the external data acquisition center. By using induction power, which is generated by the motor's shaft rotation, the sensor node is self-sustaining; therefore, no power line is required. A monitoring system, equipped with novel sensing nodes, was constructed to test its performance. The test results illustrate that, the novel sensing node developed in this study can effectively enhance the reliability of the motor monitoring system and it is expected to be a valuable technology, which will be available to the plant for implementation in a reliable motor management program. PMID:27873798

  12. Preparation and measurement of FBG-based length, temperature, and vibration sensors

    NASA Astrophysics Data System (ADS)

    Mikel, Bretislav; Helan, Radek; Buchta, Zdenek; Jelinek, Michal; Cip, Ondrej

    2016-12-01

    We present system of structure health measurement by optical fiber sensors based on fiber Bragg gratings. Our system is focused to additionally install to existing buildings. We prepared first set-up of the system to monitoring of the nuclear power plant containment shape deformation. The presented system can measure up to several tens of sensors simultaneously. Each sensor contains optical fiber grating to measurement of change of length and the other independed fiber grating to monitor the temperature and the other ineligible effects.

  13. 29 CFR 1910.1027 - Cadmium.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ..., measurements that demonstrate the effectiveness of the system in controlling exposure, such as capture velocity...) Measurements of the system's effectiveness in controlling exposure shall be made as necessary within five... recirculated into the workplace, the system shall have a high efficiency filter and be monitored to assure...

  14. Water-quality and hydrogeologic data used to evaluate the effects of farming systems on ground-water quality at the Management Systems Evaluation Area near Princeton,Minnesota, 1991-95

    USGS Publications Warehouse

    Landon, M.K.; Delin, G.N.; Nelson, K.J.; Regan, C.P.; Lamb, J.A.; Larson, S.J.; Capel, P.D.; Anderson, J.L.; Dowdy, R.H.

    1997-01-01

    The Minnesota Management Systems Evaluation Area (MSEA) project was part of a multi-scale, inter-agency initiative to evaluate the effects of agricultural management systems on water quality in the midwest corn belt. The research area was located in the Anoka Sand Plain about 5 kilometers southwest of Princeton, Minnesota. The ground-water-quality monitoring network within and immediately surrounding the research area consisted of 73 observation wells and 25 multiport wells. The primary objectives of the ground-water monitoring program at the Minnesota MSEA were to: (1) determine the effects of three farming systems on ground-water quality, and (2) understand the processes and factors affecting the loading, transport, and fate of agricultural chemicals in ground water at the site. This report presents well construction, geologic, water-level, chemical application, water-quality, and quality-assurance data used to evaluate the effects of farming systems on ground-water quality during 1991-95.

  15. A Java Program for the Viewing of Ambient Data

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fisher, A.

    2004-09-03

    The BaBar detector system has a large number of sensors and data feeds, called ambient feeds. These feeds are vital to the operation and monitoring of the Pep rings and the BaBar system. In order to more easily monitor these systems a simple web interface to display graphical representations of the data is needed. Towards this end it was decided that using a Java Web Servlet (Sun Microsystems) would be an effective and simple way to achieve this effect. By combining Web Servlets with the Corba Technology (OMG) this provides a way for many people to access data from anywheremore » in the world. Using this type of program in conjunction with the HEP AIDA systems for graphing makes a powerful tool for the monitoring of the BaBar system. An overview of the BaBar system, and how the Ambient data is given. The uses and limitations of this method for viewing the data as well as examples of other ways to access the data and potential other uses for the servlet are also discussed.« less

  16. Self-testing security sensor for monitoring closure of vault doors and the like

    DOEpatents

    Cawthorne, Duane C.

    1997-05-27

    A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member.

  17. Self-testing security sensor for monitoring closure of vault doors and the like

    DOEpatents

    Cawthorne, D.C.

    1997-05-27

    A self-testing device is provided for a monitoring system for monitoring whether a closure member such as a door or window is closed. The monitoring system includes a switch unit mounted on the frame of the closure member being monitored and including magnetically biased switches connected in one or more electrical monitoring circuits, and a door magnet unit mounted on the closure member being monitored. The door magnet includes one or more permanent magnets that produce a magnetic field which, when the closure member is closed, cause said switches to assume a first state. When the closure member is opened, the switches switch to a second, alarm state. The self-testing device is electrically controllable from a remote location and produces a canceling or diverting magnetic field which simulates the effect of movement of the closure member from the closed position thereof without any actual movement of the member. 5 figs.

  18. Technological advances in perioperative monitoring: Current concepts and clinical perspectives

    PubMed Central

    Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar

    2015-01-01

    Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any. PMID:25788767

  19. Technological advances in perioperative monitoring: Current concepts and clinical perspectives.

    PubMed

    Chilkoti, Geetanjali; Wadhwa, Rachna; Saxena, Ashok Kumar

    2015-01-01

    Minimal mandatory monitoring in the perioperative period recommended by Association of Anesthetists of Great Britain and Ireland and American Society of Anesthesiologists are universally acknowledged and has become an integral part of the anesthesia practice. The technologies in perioperative monitoring have advanced, and the availability and clinical applications have multiplied exponentially. Newer monitoring techniques include depth of anesthesia monitoring, goal-directed fluid therapy, transesophageal echocardiography, advanced neurological monitoring, improved alarm system and technological advancement in objective pain assessment. Various factors that need to be considered with the use of improved monitoring techniques are their validation data, patient outcome, safety profile, cost-effectiveness, awareness of the possible adverse events, knowledge of technical principle and ability of the convenient routine handling. In this review, we will discuss the new monitoring techniques in anesthesia, their advantages, deficiencies, limitations, their comparison to the conventional methods and their effect on patient outcome, if any.

  20. Evaluation of Biofilms and the Effects of Biocides Thereon

    NASA Technical Reports Server (NTRS)

    Pierson, Duane L. (Inventor); Koenig, David W. (Inventor); Mishra, Saroj K. (Inventor)

    2002-01-01

    Biofilm formation is monitored by real-time continuous measurement. Images are formed of sessile cells on a surface and planktonic cells adjacent the surface. The attachment of cells to the surface is measured and quantitated, and sessile and planktonic cells are distinguished using image processing techniques. Single cells as well as colonies are monitored on or adjacent a variety of substrates. Flowing streams may be monitored. The effects of biocides on biofilms commonly isolated from recyclable water systems are measured.

  1. Integration of Wireless Sensor Networks into Cyberinfrastructure for Monitoring Hawaiian ``Mountain-to-Sea'' Environments

    NASA Astrophysics Data System (ADS)

    Kido, Michael H.; Mundt, Carsten W.; Montgomery, Kevin N.; Asquith, Adam; Goodale, David W.; Kaneshiro, Kenneth Y.

    2008-10-01

    Monitoring the complex environmental relationships and feedbacks of ecosystems on catchment (or mountain)-to-sea scales is essential for social systems to effectively deal with the escalating impacts of expanding human populations globally on watersheds. However, synthesis of emerging technologies into a robust observing platform for the monitoring of coupled human-natural environments on extended spatial scales has been slow to develop. For this purpose, the authors produced a new cyberinfrastructure for environmental monitoring which successfully merged the use of wireless sensor technologies, grid computing with three-dimensional (3D) geospatial data visualization/exploration, and a secured internet portal user interface, into a working prototype for monitoring mountain-to-sea environments in the high Hawaiian Islands. A use-case example is described in which native Hawaiian residents of Waipa Valley (Kauai) utilized the technology to monitor the effects of regional weather variation on surface water quality/quantity response, to better understand their local hydrologic cycle, monitor agricultural water use, and mitigate the effects of lowland flooding.

  2. Integration of wireless sensor networks into cyberinfrastructure for monitoring Hawaiian "mountain-to-sea" environments.

    PubMed

    Kido, Michael H; Mundt, Carsten W; Montgomery, Kevin N; Asquith, Adam; Goodale, David W; Kaneshiro, Kenneth Y

    2008-10-01

    Monitoring the complex environmental relationships and feedbacks of ecosystems on catchment (or mountain)-to-sea scales is essential for social systems to effectively deal with the escalating impacts of expanding human populations globally on watersheds. However, synthesis of emerging technologies into a robust observing platform for the monitoring of coupled human-natural environments on extended spatial scales has been slow to develop. For this purpose, the authors produced a new cyberinfrastructure for environmental monitoring which successfully merged the use of wireless sensor technologies, grid computing with three-dimensional (3D) geospatial data visualization/exploration, and a secured internet portal user interface, into a working prototype for monitoring mountain-to-sea environments in the high Hawaiian Islands. A use-case example is described in which native Hawaiian residents of Waipa Valley (Kauai) utilized the technology to monitor the effects of regional weather variation on surface water quality/quantity response, to better understand their local hydrologic cycle, monitor agricultural water use, and mitigate the effects of lowland flooding.

  3. Ability to monitor driving under the influence of marijuana among non-fatal motor-vehicle crashes: An evaluation of the Colorado electronic accident reporting system.

    PubMed

    Peterson, Alexis B; Sauber-Schatz, Erin K; Mack, Karin A

    2018-06-01

    As more states legalize medical/recreational marijuana use, it is important to determine if state motor-vehicle surveillance systems can effectively monitor and track driving under the influence (DUI) of marijuana. This study assessed Colorado's Department of Revenue motor-vehicle crash data system, Electronic Accident Reporting System (EARS), to monitor non-fatal crashes involving driving under the influence (DUI) of marijuana. Centers for Disease Control and Prevention guidelines on surveillance system evaluation were used to assess EARS' usefulness, flexibility, timeliness, simplicity, acceptability, and data quality. We assessed system components, interviewed key stakeholders, and analyzed completeness of Colorado statewide 2014 motor-vehicle crash records. EARS contains timely and complete data, but does not effectively monitor non-fatal motor-vehicle crashes related to DUI of marijuana. Information on biological sample type collected from drivers and toxicology results were not recorded into EARS; however, EARS is a flexible system that can incorporate new data without increasing surveillance system burden. States, including Colorado, could consider standardization of drug testing and mandatory reporting policies for drivers involved in motor-vehicle crashes and proactively address the narrow window of time for sample collection to improve DUI of marijuana surveillance. Practical applications: The evaluation of state motor-vehicle crash systems' ability to capture crashes involving drug impaired driving (DUID) is a critical first step for identifying frequency and risk factors for crashes related to DUID. Published by Elsevier Ltd.

  4. Maintaining the Health of Software Monitors

    NASA Technical Reports Server (NTRS)

    Person, Suzette; Rungta, Neha

    2013-01-01

    Software health management (SWHM) techniques complement the rigorous verification and validation processes that are applied to safety-critical systems prior to their deployment. These techniques are used to monitor deployed software in its execution environment, serving as the last line of defense against the effects of a critical fault. SWHM monitors use information from the specification and implementation of the monitored software to detect violations, predict possible failures, and help the system recover from faults. Changes to the monitored software, such as adding new functionality or fixing defects, therefore, have the potential to impact the correctness of both the monitored software and the SWHM monitor. In this work, we describe how the results of a software change impact analysis technique, Directed Incremental Symbolic Execution (DiSE), can be applied to monitored software to identify the potential impact of the changes on the SWHM monitor software. The results of DiSE can then be used by other analysis techniques, e.g., testing, debugging, to help preserve and improve the integrity of the SWHM monitor as the monitored software evolves.

  5. Distributed architecture and distributed processing mode in urban sewage treatment

    NASA Astrophysics Data System (ADS)

    Zhou, Ruipeng; Yang, Yuanming

    2017-05-01

    Decentralized rural sewage treatment facility over the broad area, a larger operation and management difficult, based on the analysis of rural sewage treatment model based on the response to these challenges, we describe the principle, structure and function in networking technology and network communications technology as the core of distributed remote monitoring system, through the application of case analysis to explore remote monitoring system features in a decentralized rural sewage treatment facilities in the daily operation and management. Practice shows that the remote monitoring system to provide technical support for the long-term operation and effective supervision of the facilities, and reduced operating, maintenance and supervision costs for development.

  6. Improved security monitoring method for network bordary

    NASA Astrophysics Data System (ADS)

    Gao, Liting; Wang, Lixia; Wang, Zhenyan; Qi, Aihua

    2013-03-01

    This paper proposes a network bordary security monitoring system based on PKI. The design uses multiple safe technologies, analysis deeply the association between network data flow and system log, it can detect the intrusion activities and position invasion source accurately in time. The experiment result shows that it can reduce the rate of false alarm or missing alarm of the security incident effectively.

  7. Construction of Expert Knowledge Monitoring and Assessment System Based on Integral Method of Knowledge Evaluation

    ERIC Educational Resources Information Center

    Golovachyova, Viktoriya N.; Menlibekova, Gulbakhyt Zh.; Abayeva, Nella F.; Ten, Tatyana L.; Kogaya, Galina D.

    2016-01-01

    Using computer-based monitoring systems that rely on tests could be the most effective way of knowledge evaluation. The problem of objective knowledge assessment by means of testing takes on a new dimension in the context of new paradigms in education. The analysis of the existing test methods enabled us to conclude that tests with selected…

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, T; Cho, M; Kang, S

    Purpose: To improve the setup accuracy of thermoplastic mask, we developed a new monitoring method based on force sensing technology and evaluated its feasibility. Methods: The thermoplastic mask setup monitoring system consists of a force sensing resistor sensor unit, a signal transport device, a control PC and an in-house software. The system is designed to monitor pressure variation between the mask and patient in real time. It also provides a warning to the user when there is a possibility of movement. A preliminary study was performed to evaluate the reliability of the sensor unit and developed monitoring system with amore » head phantom. Then, a simulation study with volunteers was conducted to evaluate the feasibility of the monitoring system. Note that the sensor unit can have multiple end-sensors and every end-sensor was confirmed to be within 2% reliability in pressure reading through a screening test. Results: To evaluate the reproducibility of the proposed monitoring system in practice, we simulated a mask setup with the head phantom. FRS sensors were attached on the face of the head phantom and pressure was monitored. For 3 repeated mask setups on the phantom, the variation of the pressure was less than 3% (only 1% larger than 2% potential uncertainty confirmed in the screening test). In the volunteer study, we intended to verify that the system could detect patient movements within the mask. Thus, volunteers were asked to turn their head or lift their chin. The system was able to detect movements effectively, confirming the clinical feasibility of the monitoring system developed. Conclusion: Through the proposed setup monitoring method, it is possible to monitor patient motion inside a mask in real time, which has never been possible with most commonly used systems using non-radiographic technology such as infrared camera system and surface imaging system. This work was supported by the Radiation Technology R&D program (No. 2013M2A2A7043498) and the Mid-career Researcher Program (2014R1A2A1A10050270) through the National Research Foundation of Korea funded by the Ministry of Science, ICT&Future Planning.« less

  9. 16S rRNA beacons for bacterial monitoring during human space missions.

    PubMed

    Larios-Sanz, Maia; Kourentzi, Katerina D; Warmflash, David; Jones, Jeffrey; Pierson, Duane L; Willson, Richard C; Fox, George E

    2007-04-01

    Microorganisms are unavoidable in space environments and their presence has, at times, been a source of problems. Concerns about disease during human space missions are particularly important considering the significant changes the immune system incurs during spaceflight and the history of microbial contamination aboard the Mir space station. Additionally, these contaminants may have adverse effects on instrumentation and life-support systems. A sensitive, highly specific system to detect, characterize, and monitor these microbial populations is essential. Herein we describe a monitoring approach that uses 16S rRNA targeted molecular beacons to successfully detect several specific bacterial groupings. This methodology will greatly simplify in-flight monitoring by minimizing sample handling and processing. We also address and provide solutions to target accessibility problems encountered in hybridizations that target 16S rRNA.

  10. A Curricular-Sampling Approach to Progress Monitoring: Mathematics Concepts and Applications

    ERIC Educational Resources Information Center

    Fuchs, Lynn S.; Fuchs, Douglas; Zumeta, Rebecca O.

    2008-01-01

    Progress monitoring is an important component of effective instructional practice. Curriculum-based measurement (CBM) is a form of progress monitoring that has been the focus of rigorous research. Two approaches for formulating CBM systems exist. The first is to assess performance regularly on a task that serves as a global indicator of competence…

  11. National best management practices monitoring summary report, program phase-in period fiscal years 2013-2014

    Treesearch

    Joan Carlson; Pam Edwards; Todd Ellsworth; Michael Eberle

    2015-01-01

    The National BMP Program provides National Core BMPs, standardized monitoring protocols to evaluate implementation and effectiveness of the National Core BMPs, and a data management system to store and analyze the resulting monitoring data. BMP evaluations are completed by interdisciplinary teams of resource specialists and include assessments of whether BMP...

  12. A vehicle health monitoring system for the Space Shuttle Reaction Control System during reentry. M.S. Thesis - Massachusetts Inst. of Technology

    NASA Technical Reports Server (NTRS)

    Rosello, Anthony David

    1995-01-01

    A general two tier framework for vehicle health monitoring of Guidance Navigation and Control (GN&C) system actuators, effectors, and propulsion devices is presented. In this context, a top level monitor that estimates jet thrust is designed for the Space Shuttle Reaction Control System (RCS) during the reentry phase of flight. Issues of importance for the use of estimation technologies in vehicle health monitoring are investigated and quantified for the Shuttle RCS demonstration application. These issues include rate of convergence, robustness to unmodeled dynamics, sensor quality, sensor data rates, and information recording objectives. Closed loop simulations indicate that a Kalman filter design is sensitive to modeling error and robust estimators may reduce this sensitivity. Jet plume interaction with the aerodynamic flowfield is shown to be a significant effect adversely impacting the ability to accurately estimate thrust.

  13. The design of multi temperature and humidity monitoring system for incubator

    NASA Astrophysics Data System (ADS)

    Yu, Junyu; Xu, Peng; Peng, Zitao; Qiang, Haonan; Shen, Xiaoyan

    2017-01-01

    Currently, there is only one monitor of the temperature and humidity in an incubator, which may cause inaccurate or unreliable data, and even endanger the life safety of the baby. In order to solve this problem,we designed a multi-point temperature and humidity monitoring system for incubators. The system uses the STC12C5A60S2 microcontrollers as the sender core chip which is connected to four AM2321 temperature and humidity sensors. We select STM32F103ZET6 core development board as the receiving end,cooperating with Zigbee wireless transmitting and receiving module to realize data acquisition and transmission. This design can realize remote real-time observation data on the computer by communicating with PC via Ethernet. Prototype tests show that the system can effectively collect and display the information of temperature and humidity of multiple incubators at the same time and there are four monitors in each incubator.

  14. High Temperatures Health Monitoring of the Condensed Water Height in Steam Pipe Systems

    NASA Technical Reports Server (NTRS)

    Lih, Shyh-Shiuh; Bar-Cohen, Yoseph; Lee, Hyeong Jae; Badescu, Mircea; Bao, Xiaoqi; Sherrit, Stewart; Takano, Nobuyuki; Ostlund, Patrick; Blosiu, Julian

    2013-01-01

    Ultrasonic probes were designed, fabricated and tested for high temperature health monitoring system. The goal of this work was to develop the health monitoring system that can determine the height level of the condensed water through the pipe wall at high temperature up to 250 deg while accounting for the effects of surface perturbation. Among different ultrasonic probe designs, 2.25 MHz probes with air backed configuration provide satisfactory results in terms of sensitivity, receiving reflections from the target through the pipe wall. A series of tests were performed using the air-backed probes under irregular conditions, such as surface perturbation and surface disturbance at elevated temperature, to qualify the developed ultrasonic system. The results demonstrate that the fabricated air-backed probes combined with advanced signal processing techniques offer the capability of health monitoring of steam pipe under various operating conditions.

  15. Piezoresistive effect of the carbon nanotube yarn embedded axially into the 3D braided composite

    NASA Astrophysics Data System (ADS)

    Ma, Xin; Cao, Xiaona

    2018-06-01

    A new method for monitoring 3D braided composite structure health in real time by embedding the carbon nanotube yarn, based on its piezoresistivity, in the composite axially has been designed. The experimental system for piezoresistive effect detection of the carbon nanotube yarn in the 3D braided composite was built, and the sensing characteristics has been analyzed for further research. Compared with other structural health monitoring methods, the monitoring technique with carbon nanotubes yarns is more suitable for internal damage detection immediately, in addition the strength of the composite can be increased by embedding carbon nanotubes yarns. This method can also be used for strain sensing, the development of intelligent materials and structure systems.

  16. Printable thermoelectric devices and conductive patterns for medical applications

    NASA Astrophysics Data System (ADS)

    Lee, Jungmin; Kim, Hyunjung; Chen, Linfeng; Choi, Sang H.; Varadan, Vijay K.

    2012-10-01

    Remote point-of-care is expected to revolutionize the modern medical practice, and many efforts have been made for the development of wireless health monitoring systems for continuously detecting the physiological signals of patients. To make the remote point-of-care generally accepted and widely used, it is necessary to develop cost-effective and durable wireless health monitoring systems. Printing technique will be helpful for the fabrication of high-quality and low-cost medical devices and systems because it allows high-resolution and high-speed fabrication, low material consumption and nano-sized patterning on both flexible and rigid substrates. Furthermore, application of thermoelectric generators can replace conventional batteries as the power sources for wireless health monitoring systems because thermoelectric generators can convert the wasted heat or the heat from nature into electricity which is required for the operation of the wireless health monitoring systems. In this research, we propose the concept of printable thermoelectric devices and conductive patterns for the realization of more portable and cost-effective medical devices. To print thermoelectric generators and conductive patterns on substrates, printing inks with special characteristics should be developed. For the development of thermoelectric inks, nano-structured thermoelectric materials are synthesized and characterized; and for the development of conductive inks, two kinds of surface treated carbon nanotubes are used as active materials.

  17. Air pollution effects field research facility: 3. UV-B exposure and monitoring system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McEvers, J.A.; Hileman, M.S.; Edwards, N.T.

    1993-03-01

    The Oak Ridge National Laboratory Outdoor UltraViolet-B (UV-B) Exposure and Monitoring Facility was developed in 1980 to provide well-controlled and -monitored exposure of specific terrestrial plant. species to elevated levels of ultraviolet (UV) radiation. The introduction of various anthropogenic agents into the earth`s stratosphere has resulted in a decrease in the volume of ozone (O{sub 3}) present here. The decrease in O{sub 3} has resulted in an increase in the level of UV radiation reaching thee earth`s surface. Of particular interest is the level of UV-B, because it has the most detrimental effect on living tissue. A thorough understanding ofmore » the effects of elevated levels of UV-B on living tissue is critical to the formulation of economic policy regarding production of such agents and alternative strategies. The UV region of interest is referred to as UV-B and corresponds to radiation with a wavelength of 290 to 320 nm. Design, operation, and performance of the automated generation, exposure, and monitoring system are described. The system has proved to be reliable and easy to maintain and operate, and it provides significant flexibility in exposure programs. The system software is described, and detailed listings are provided. The ability to expose plants to controlled set point percentages of UV-B above the ambient level was developed.« less

  18. Induction of Inflammation In Vivo by Electrocardiogram Sensor Operation Using Wireless Power Transmission.

    PubMed

    Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha

    2017-12-14

    Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system.

  19. Induction of Inflammation In Vivo by Electrocardiogram Sensor Operation Using Wireless Power Transmission

    PubMed Central

    Heo, Jin-Chul; Kim, Beomjoon; Kim, Yoon-Nyun; Kim, Dae-Kwang; Lee, Jong-Ha

    2017-01-01

    Prolonged monitoring by cardiac electrocardiogram (ECG) sensors is useful for patients with emergency heart conditions. However, implant monitoring systems are limited by lack of tissue biocompatibility. Here, we developed an implantable ECG sensor for real-time monitoring of ventricular fibrillation and evaluated its biocompatibility using an animal model. The implantable sensor comprised transplant sensors with two electrodes, a wireless power transmission system, and a monitoring system. The sensor was inserted into the subcutaneous tissue of the abdominal area and operated for 1 h/day for 5 days using a wireless power system. Importantly, the sensor was encapsulated by subcutaneous tissue and induced angiogenesis, inflammation, and phagocytosis. In addition, we observed that the levels of inflammation-related markers increased with wireless-powered transmission via the ECG sensor; in particular, levels of the Th-1 cytokine interleukin-12 were significantly increased. The results showed that induced tissue damage was associated with the use of wireless-powered sensors. We also investigated research strategies for the prevention of adverse effects caused by lack of tissue biocompatibility of a wireless-powered ECG monitoring system and provided information on the clinical applications of inflammatory reactions in implant treatment using the wireless-powered transmission system. PMID:29240666

  20. Integrated structural health monitoring

    NASA Astrophysics Data System (ADS)

    Farrar, Charles R.; Sohn, Hoon; Fugate, Michael L.; Czarnecki, Jerry J.

    2001-07-01

    Structural health monitoring is the implementation of a damage detection strategy for aerospace, civil and mechanical engineering infrastructure. Typical damage experienced by this infrastructure might be the development of fatigue cracks, degradation of structural connections, or bearing wear in rotating machinery. The goal of the research effort reported herein is to develop a robust and cost-effective structural health monitoring solution by integrating and extending technologies from various engineering and information technology disciplines. It is the author's opinion that all structural health monitoring systems must be application specific. Therefore, a specific application, monitoring welded moment resisting steel frame connections in structures subjected to seismic excitation, is described along with the motivation for choosing this application. The structural health monitoring solution for this application will integrate structural dynamics, wireless data acquisition, local actuation, micro-electromechanical systems (MEMS) technology, and statistical pattern recognition algorithms. The proposed system is based on an assessment of the deficiencies associated with many current structural health monitoring technologies including past efforts by the authors. This paper provides an example of the integrated approach to structural health monitoring being undertaken at Los Alamos National Laboratory and summarizes progress to date on various aspects of the technology development.

  1. GUI Type Fault Diagnostic Program for a Turboshaft Engine Using Fuzzy and Neural Networks

    NASA Astrophysics Data System (ADS)

    Kong, Changduk; Koo, Youngju

    2011-04-01

    The helicopter to be operated in a severe flight environmental condition must have a very reliable propulsion system. On-line condition monitoring and fault detection of the engine can promote reliability and availability of the helicopter propulsion system. A hybrid health monitoring program using Fuzzy Logic and Neural Network Algorithms can be proposed. In this hybrid method, the Fuzzy Logic identifies easily the faulted components from engine measuring parameter changes, and the Neural Networks can quantify accurately its identified faults. In order to use effectively the fault diagnostic system, a GUI (Graphical User Interface) type program is newly proposed. This program is composed of the real time monitoring part, the engine condition monitoring part and the fault diagnostic part. The real time monitoring part can display measuring parameters of the study turboshaft engine such as power turbine inlet temperature, exhaust gas temperature, fuel flow, torque and gas generator speed. The engine condition monitoring part can evaluate the engine condition through comparison between monitoring performance parameters the base performance parameters analyzed by the base performance analysis program using look-up tables. The fault diagnostic part can identify and quantify the single faults the multiple faults from the monitoring parameters using hybrid method.

  2. Job monitoring on DIRAC for Belle II distributed computing

    NASA Astrophysics Data System (ADS)

    Kato, Yuji; Hayasaka, Kiyoshi; Hara, Takanori; Miyake, Hideki; Ueda, Ikuo

    2015-12-01

    We developed a monitoring system for Belle II distributed computing, which consists of active and passive methods. In this paper we describe the passive monitoring system, where information stored in the DIRAC database is processed and visualized. We divide the DIRAC workload management flow into steps and store characteristic variables which indicate issues. These variables are chosen carefully based on our experiences, then visualized. As a result, we are able to effectively detect issues. Finally, we discuss the future development for automating log analysis, notification of issues, and disabling problematic sites.

  3. Personalized USB Biosensor Module for Effective ECG Monitoring.

    PubMed

    Sladojević, Srdjan; Arsenović, Marko; Lončar-Turukalo, Tatjana; Sladojević, Miroslava; Ćulibrk, Dubravko

    2016-01-01

    The burden of chronic disease and associated disability present a major threat to financial sustainability of healthcare delivery systems. The need for cost-effective early diagnosis and disease prevention is evident driving the development of personalized home health solutions. The proposed solution presents an easy to use ECG monitoring system. The core hardware component is a biosensor dongle with sensing probes at one end, and micro USB interface at the other end, offering reliable and unobtrusive sensing, preprocessing and storage. An additional component is a smart phone, providing both the biosensor's power supply and an intuitive user application for the real-time data reading. The system usage is simplified, with innovative solutions offering plug and play functionality avoiding additional driver installation. Personalized needs could be met with different sensor combinations enabling adequate monitoring in chronic disease, during physical activity and in the rehabilitation process.

  4. Design and rationale of the ANALYZE ST study: a prospective, nonrandomized, multicenter ST monitoring study to detect acute coronary syndrome events in implantable cardioverter-defibrillator patients.

    PubMed

    Gibson, C Michael; Krucoff, Mitchell; Kirtane, Ajay J; Rao, Sunil V; Mackall, Judith A; Matthews, Ray; Saba, Samir; Waksman, Ron; Holmes, David

    2014-10-01

    In the setting of ST-segment elevation myocardial infarction, timely restoration of normal blood flow is associated with improved myocardial salvage and survival. Despite improvements in door-to-needle and door-to-balloon times, there remains an unmet need with respect to improved symptom-to-door times. A prior report of an implanted device to monitor ST-segment deviation demonstrated very short times to reperfusion among patients with an acute coronary syndrome (ACS) with documented thrombotic occlusion. The goal of the ANALYZE ST study is to evaluate the safety and effectiveness of a novel ST-segment monitoring feature using an existing implantable cardioverter-defibrillator (ICD) among patients with known coronary artery disease. The ANALYZE ST study is a prospective, nonrandomized, multicenter, pivotal Investigational Device Exemption study enrolling 5,228 patients with newly implanted ICD systems for standard clinical indications who also have a documented history of coronary artery disease. Patients will be monitored for 48 months, during which effectiveness of the device for the purpose of early detection of cardiac injury will be evaluated by analyzing the sensitivity of the ST monitoring feature to identify clinical ACS events. In addition, the safety of the ST monitoring feature will be evaluated through the assessment of the percentage of patients for which monitoring produces a false-positive event over the course of 12 months. The ANALYZE ST trial is testing the hypothesis that the ST monitoring feature in the Fortify ST ICD system (St. Jude Medical, Inc., St. Paul, MN) (or other ICD systems with the ST monitoring feature) will accurately identify patients with clinical ACS events. Copyright © 2014 Mosby, Inc. All rights reserved.

  5. MINIMIZING COGNITIVE ERRORS IN SITE-SPECIFIC CAUSAL ASSESSMENT

    EPA Science Inventory

    Interest in causal investigations in aquatic systems has been a natural outgrowth of the increased use of biological monitoring to characterize the condition of resources. Although biological monitoring approaches are critical tools for detecting whether effects are occurring, t...

  6. Biomedical sensing and display concept improves brain wave monitoring

    NASA Technical Reports Server (NTRS)

    Trent, R. L.

    1970-01-01

    Concept for increasing effectiveness of biomedical sensing and display promises greater monitoring capability while lessening high skill requirements in operating personnel. New concept overcomes deficiencies of current system by employing increased number of probes and microelectronic preamplifiers.

  7. Monitoring And Controlling Hydroponic Flow

    NASA Technical Reports Server (NTRS)

    Dreschel, Thomas W.

    1992-01-01

    Pressure-monitoring and -controlling apparatus maintains slight suction required on nutrient solution in apparatus described in "Tubular Membrane Plant-Growth Unit" (KSC-11375), while overcoming gravity effects on operation of system on Earth. Suction helps to hold solution in tubular membrane.

  8. Monitoring and control requirement definition study for Dispersed Storage and Generation (DSG), volume 1

    NASA Technical Reports Server (NTRS)

    1980-01-01

    Twenty-four functional requirements were prepared under six categories and serve to indicate how to integrate dispersed storage generation (DSG) systems with the distribution and other portions of the electric utility system. Results indicate that there are no fundamental technical obstacles to prevent the connection of dispersed storage and generation to the distribution system. However, a communication system of some sophistication is required to integrate the distribution system and the dispersed generation sources for effective control. The large-size span of generators from 10 KW to 30 MW means that a variety of remote monitoring and control may be required. Increased effort is required to develop demonstration equipment to perform the DSG monitoring and control functions and to acquire experience with this equipment in the utility distribution environment.

  9. Monitoring and Reporting Tools of the International Data Centre and International Monitoring System

    NASA Astrophysics Data System (ADS)

    Lastowka, L.; Anichenko, A.; Galindo, M.; Villagran Herrera, M.; Mori, S.; Malakhova, M.; Daly, T.; Otsuka, R.; Stangel, H.

    2007-05-01

    The Comprehensive Test-Ban Treaty (CTBT) which prohibits all nuclear explosions was opened for signature in 1996. Since then, the Preparatory Commission for the CTBT Organization has been working towards the establishment of a global verification regime to monitor compliance with the ban on nuclear testing. The International Monitoring System (IMS) comprises facilities for seismic, hydroacoustic, infrasound and radionuclide monitoring, and the means of communication. This system is supported by the International Data Centre (IDC), which provides objective products and services necessary for effective global monitoring. Upon completion of the IMS, 321 stations will be contributing to both near real-time and reviewed data products. Currently there are 194 facilities in IDC operations. This number is expected to increase by about 40% over the next few years, necessitating methods and tools to effectively handle the expansion. The requirements of high data availability as well as operational transparency are fundamental principals of IMS network operations, therefore, a suite of tools for monitoring and reporting have been developed. These include applications for monitoring Global Communication Infrastructure (GCI) links, detecting outages in continuous and segmented data, monitoring the status of data processing and forwarding to member states, and for systematic electronic communication and problem ticketing. The operation of the IMS network requires the help of local specialists whose cooperation is in some cases ensured by contracts or other agreements. The PTS (Provisional Technical Secretariat) strives to make the monitoring of the IMS as standardized and efficient as possible, and has therefore created the Operations Centre in which the use of most the tools are centralized. Recently the tasks of operations across all technologies, including the GCI, have been centralized within a single section of the organization. To harmonize the operations, an ongoing State of Health monitoring project will provide an integrated view of network, station and GCI performance and will provide system metrics. Comprehensive procedures will be developed to utilize this tool. However, as the IMS network expands, easier access to more information will cause additional challenges, mainly with human resources, to analyze and manage these metrics.

  10. Study on the position accuracy of a mechanical alignment system

    NASA Astrophysics Data System (ADS)

    Cai, Yimin

    In this thesis, we investigated the precision level and established the baseline achieved by a mechanical alignment system using datums and reference surfaces. The factors which affect the accuracy of mechanical alignment system were studied and methodology was developed to suppress these factors so as to reach its full potential precision. In order to characterize the mechanical alignment system quantitatively, a new optical position monitoring system by using quadrant detectors has been developed in this thesis, it can monitor multi-dimensional degrees of mechanical workpieces in real time with high precision. We studied the noise factors inside the system and optimized the optical system. Based on the fact that one of the major limiting noise factors is the shifting of the laser beam, a noise cancellation technique has been developed successfully to suppress this noise, the feasibility of an ultra high resolution (<20 A) for displacement monitoring has been demonstrated. Using the optical position monitoring system, repeatability experiment of the mechanical alignment system has been conducted on different kinds of samples including steel, aluminum, glass and plastics with the same size 100mm x 130mm. The alignment accuracy was studied quantitatively rather than qualitatively before. In a controlled environment, the alignment precision can be improved 5 folds by securing the datum without other means of help. The alignment accuracy of an aluminum workpiece having reference surface by milling is about 3 times better than by shearing. Also we have found that sample material can have fairly significant effect on the alignment precision of the system. Contamination trapped between the datum and reference surfaces in mechanical alignment system can cause errors of registration or reduce the level of manufacturing precision. In the thesis, artificial and natural dust particles were used to simulate the real situations and their effects on system precision have been investigated. In this experiment, we discovered two effective cleaning processes.

  11. Monitoring osseointegration and developing intelligent systems (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Salvino, Liming W.

    2017-05-01

    Effective monitoring of structural and biological systems is an extremely important research area that enables technology development for future intelligent devices, platforms, and systems. This presentation provides an overview of research efforts funded by the Office of Naval Research (ONR) to establish structural health monitoring (SHM) methodologies in the human domain. Basic science efforts are needed to utilize SHM sensing, data analysis, modeling, and algorithms to obtain the relevant physiological and biological information for human-specific health and performance conditions. This overview of current research efforts is based on the Monitoring Osseointegrated Prosthesis (MOIP) program. MOIP develops implantable and intelligent prosthetics that are directly anchored to the bone of residual limbs. Through real-time monitoring, sensing, and responding to osseointegration of bones and implants as well as interface conditions and environment, our research program aims to obtain individualized actionable information for implant failure identification, load estimation, infection mitigation and treatment, as well as healing assessment. Looking ahead to achieve ultimate goals of SHM, we seek to expand our research areas to cover monitoring human, biological and engineered systems, as well as human-machine interfaces. Examples of such include 1) brainwave monitoring and neurological control, 2) detecting and evaluating brain injuries, 3) monitoring and maximizing human-technological object teaming, and 4) closed-loop setups in which actions can be triggered automatically based on sensors, actuators, and data signatures. Finally, some ongoing and future collaborations across different disciplines for the development of knowledge automation and intelligent systems will be discussed.

  12. IoT based Growth Monitoring System of Guava (Psidium guajava L.) Fruits

    NASA Astrophysics Data System (ADS)

    Slamet, W.; Irham, N. M.; Sutan, M. S. A.

    2018-05-01

    Growth monitoring of plant is important especially to evaluate the influence of environment or growing condition on its productivity. One way to monitor the plant growth is by measuring the radial growth (i.e., the change of circumference) of certain part of plant such as trunk, branch, and fruit. In this study we develop an internet of things (IoT) based monitoring system of radial growth of plant using a low-cost optoelectronic sensor. The system was applied to monitor radial growth of guava fruits (Psidium guajava L.). The principle of the developed sensor is based on the optoelectronic sensor which detects alternating white and black narrow bar printed on reflective tapes. Reflective tape was installed encircling the fruit. The movement of reflective tapes will follow the radial growth of the fruit so that the infrared sensor on the optoelectronic would response reflective tapes movement. This device is designed to measure object continuously and long-term monitor with minimum maintenance. The data collected by the sensors are then sent to the server and also can be monitored in real-time. Based on field test, at current stage, the developed sensor could measure the radial growth of the fruits with a maximum error 2 mm. In term of data transfer, the success rate of the developed system was 97.54%. The result indicated that the developed system can be used as an effective tool for growth monitoring of plant.

  13. An Air Quality Data Analysis System for Interrelating Effects, Standards and Needed Source Reductions

    ERIC Educational Resources Information Center

    Larsen, Ralph I.

    1973-01-01

    Makes recommendations for a single air quality data system (using average time) for interrelating air pollution effects, air quality standards, air quality monitoring, diffusion calculations, source-reduction calculations, and emission standards. (JR)

  14. An intelligent service matching method for mechanical equipment condition monitoring using the fibre Bragg grating sensor network

    NASA Astrophysics Data System (ADS)

    Zhang, Fan; Zhou, Zude; Liu, Quan; Xu, Wenjun

    2017-02-01

    Due to the advantages of being able to function under harsh environmental conditions and serving as a distributed condition information source in a networked monitoring system, the fibre Bragg grating (FBG) sensor network has attracted considerable attention for equipment online condition monitoring. To provide an overall conditional view of the mechanical equipment operation, a networked service-oriented condition monitoring framework based on FBG sensing is proposed, together with an intelligent matching method for supporting monitoring service management. In the novel framework, three classes of progressive service matching approaches, including service-chain knowledge database service matching, multi-objective constrained service matching and workflow-driven human-interactive service matching, are developed and integrated with an enhanced particle swarm optimisation (PSO) algorithm as well as a workflow-driven mechanism. Moreover, the manufacturing domain ontology, FBG sensor network structure and monitoring object are considered to facilitate the automatic matching of condition monitoring services to overcome the limitations of traditional service processing methods. The experimental results demonstrate that FBG monitoring services can be selected intelligently, and the developed condition monitoring system can be re-built rapidly as new equipment joins the framework. The effectiveness of the service matching method is also verified by implementing a prototype system together with its performance analysis.

  15. Development, application, and sensitivity analysis of a water quality index for drinking water management in small systems.

    PubMed

    Scheili, A; Rodriguez, Manuel J; Sadiq, R

    2015-11-01

    The aim of this study was to produce a drinking water assessment tool for operators of small distribution systems. A drinking water quality index (DWQI) was developed and applied to small systems based on the water quality index of the Canadian Council of Ministers of Environment. The drinking water quality index was adapted to specific needs by creating four drinking water quality scenarios. First, the temporal and spatial dimensions of drinking water quality variability were taken into account. The DWQI was designed to express global drinking water quality according to different monitoring frequencies. Daily, monthly, and seasonal assessment was also considered. With the data made available, it was possible to use the index as a spatial monitoring tool and express water quality in different points in the distribution system. Moreover, adjustments were made to prioritize the type of contaminant to monitor. For instance, monitoring contaminants with acute health effects led to a scenario based on daily measures, including easily accessible and affordable water quality parameters. On the other hand, contaminants with chronic effects, especially disinfection by-products, were considered in a seasonal monitoring scenario where disinfection by-product reference values were redefined according to their seasonal variability. A sensitivity analysis was also carried out to validate the index. Globally, the DWQI developed is adapted to the needs of small systems. In fact, expressing drinking water quality using the DWQI contributes to the identification of problematic periods and segments in the distribution system. Further work may include this index in the development of a customized decision-making tool for small-system operators and managers.

  16. An IoT-cloud Based Wearable ECG Monitoring System for Smart Healthcare.

    PubMed

    Yang, Zhe; Zhou, Qihao; Lei, Lei; Zheng, Kan; Xiang, Wei

    2016-12-01

    Public healthcare has been paid an increasing attention given the exponential growth human population and medical expenses. It is well known that an effective health monitoring system can detect abnormalities of health conditions in time and make diagnoses according to the gleaned data. As a vital approach to diagnose heart diseases, ECG monitoring is widely studied and applied. However, nearly all existing portable ECG monitoring systems cannot work without a mobile application, which is responsible for data collection and display. In this paper, we propose a new method for ECG monitoring based on Internet-of-Things (IoT) techniques. ECG data are gathered using a wearable monitoring node and are transmitted directly to the IoT cloud using Wi-Fi. Both the HTTP and MQTT protocols are employed in the IoT cloud in order to provide visual and timely ECG data to users. Nearly all smart terminals with a web browser can acquire ECG data conveniently, which has greatly alleviated the cross-platform issue. Experiments are carried out on healthy volunteers in order to verify the reliability of the entire system. Experimental results reveal that the proposed system is reliable in collecting and displaying real-time ECG data, which can aid in the primary diagnosis of certain heart diseases.

  17. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, J; Walt Kubilius, W; Thomas Kmetz, T

    Resource Conservation and Recovery Act (RCRA) requirements for hazardous waste facilities include 30 years of post-closure monitoring. The use of an objective-based monitoring strategy allows for a significant reduction in the amount of groundwater monitoring required, as the groundwater remediation transitions from an active biosparging system to monitored natural attenuation. The lifecycle of groundwater activities at the landfill has progressed from detection monitoring and plume characterization, to active groundwater remediation, and now to monitored natural attenuation and postclosure monitoring. Thus, the objectives of the groundwater monitoring have changed accordingly. Characterization monitoring evaluated what biogeochemical natural attenuation processes were occurring andmore » determined that elevated levels of radium were naturally occurring. Process monitoring of the biosparging system required comprehensive sampling network up- and down-gradient of the horizontal wells to verify its effectiveness. Currently, the scope of monitoring and reporting can be significantly reduced as the objective is to demonstrate that the alternate concentration limits (ACL) are being met at the point of compliance wells and the maximum contaminant level (MCL) is being met at the surface water point of exposure. The proposed reduction is estimated to save about $2M over the course of the remaining 25 years of postclosure monitoring.« less

  18. General Purpose Data-Driven Monitoring for Space Operations

    NASA Technical Reports Server (NTRS)

    Iverson, David L.; Martin, Rodney A.; Schwabacher, Mark A.; Spirkovska, Liljana; Taylor, William McCaa; Castle, Joseph P.; Mackey, Ryan M.

    2009-01-01

    As modern space propulsion and exploration systems improve in capability and efficiency, their designs are becoming increasingly sophisticated and complex. Determining the health state of these systems, using traditional parameter limit checking, model-based, or rule-based methods, is becoming more difficult as the number of sensors and component interactions grow. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. System health can be monitored by comparing real-time operating data with these nominal characterizations, providing detection of anomalous data signatures indicative of system faults or failures. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. The scope of IMS based data-driven monitoring applications continues to expand with current development activities. Successful IMS deployment in the International Space Station (ISS) flight control room to monitor ISS attitude control systems has led to applications in other ISS flight control disciplines, such as thermal control. It has also generated interest in data-driven monitoring capability for Constellation, NASA's program to replace the Space Shuttle with new launch vehicles and spacecraft capable of returning astronauts to the moon, and then on to Mars. Several projects are currently underway to evaluate and mature the IMS technology and complementary tools for use in the Constellation program. These include an experiment on board the Air Force TacSat-3 satellite, and ground systems monitoring for NASA's Ares I-X and Ares I launch vehicles. The TacSat-3 Vehicle System Management (TVSM) project is a software experiment to integrate fault and anomaly detection algorithms and diagnosis tools with executive and adaptive planning functions contained in the flight software on-board the Air Force Research Laboratory TacSat-3 satellite. The TVSM software package will be uploaded after launch to monitor spacecraft subsystems such as power and guidance, navigation, and control (GN&C). It will analyze data in real-time to demonstrate detection of faults and unusual conditions, diagnose problems, and react to threats to spacecraft health and mission goals. The experiment will demonstrate the feasibility and effectiveness of integrated system health management (ISHM) technologies with both ground and on-board experiments.

  19. Mobile communication using a mobile phone with a glucometer for glucose control in Type 2 patients with diabetes: as effective as an Internet-based glucose monitoring system.

    PubMed

    Cho, Jae-Hyoung; Lee, Hye-Chung; Lim, Dong-Jun; Kwon, Hyuk-Sang; Yoon, Kun-Ho

    2009-01-01

    A mobile phone with a glucometer integrated into the battery pack (the 'Diabetes Phone') was launched in Korea in 2003. We compared its effect on management of type 2 diabetes to the Internet-based glucose monitoring system (IBGMS), which had been studied previously. We conducted a randomized trial involving 69 patients for three months. Participants were assigned to an Internet group or a phone group. The phone group communicated with medical staff through the mobile phone only. Their glucose-monitoring data were automatically transferred to individual, web-based charts and they received medical recommendations by short message service. The Internet group used the IBGMS. There were no significant differences between the groups at baseline. After three months' intervention, HbA(1c) levels of both groups had decreased significantly, from 7.6% to 6.9% for the Internet group and from 8.3% to 7.1% for the phone group (P < 0.01). Levels of patient satisfaction and adherence to medical advice were similar. Mobile, bidirectional communication between doctors and patients using the diabetes phone was as effective for glucose control as the previously-studied Internet-based monitoring system and it was good for patient satisfaction and adherence.

  20. The Gypsy Moth Event Monitor for FVS: a tool for forest and pest managers

    Treesearch

    Kurt W. Gottschalk; Anthony W. Courter

    2007-01-01

    The Gypsy Moth Event Monitor is a program that simulates the effects of gypsy moth, Lymantria dispar (L.), within the confines of the Forest Vegetation Simulator (FVS). Individual stands are evaluated with a susceptibility index system to determine the vulnerability of the stand to the effects of gypsy moth. A gypsy moth outbreak is scheduled in the...

  1. HappyFace as a generic monitoring tool for HEP experiments

    NASA Astrophysics Data System (ADS)

    Kawamura, Gen; Magradze, Erekle; Musheghyan, Haykuhi; Quadt, Arnulf; Rzehorz, Gerhard

    2015-12-01

    The importance of monitoring on HEP grid computing systems is growing due to a significant increase in their complexity. Computer scientists and administrators have been studying and building effective ways to gather information on and clarify a status of each local grid infrastructure. The HappyFace project aims at making the above-mentioned workflow possible. It aggregates, processes and stores the information and the status of different HEP monitoring resources into the common database of HappyFace. The system displays the information and the status through a single interface. However, this model of HappyFace relied on the monitoring resources which are always under development in the HEP experiments. Consequently, HappyFace needed to have direct access methods to the grid application and grid service layers in the different HEP grid systems. To cope with this issue, we use a reliable HEP software repository, the CernVM File System. We propose a new implementation and an architecture of HappyFace, the so-called grid-enabled HappyFace. It allows its basic framework to connect directly to the grid user applications and the grid collective services, without involving the monitoring resources in the HEP grid systems. This approach gives HappyFace several advantages: Portability, to provide an independent and generic monitoring system among the HEP grid systems. Eunctionality, to allow users to perform various diagnostic tools in the individual HEP grid systems and grid sites. Elexibility, to make HappyFace beneficial and open for the various distributed grid computing environments. Different grid-enabled modules, to connect to the Ganga job monitoring system and to check the performance of grid transfers among the grid sites, have been implemented. The new HappyFace system has been successfully integrated and now it displays the information and the status of both the monitoring resources and the direct access to the grid user applications and the grid collective services.

  2. The Global Drought Information System - A Decision Support Tool with Global Applications

    NASA Astrophysics Data System (ADS)

    Arndt, D. S.; Brewer, M.; Heim, R. R., Jr.

    2014-12-01

    Drought is a natural hazard which can cause famine in developing countries and severe economic hardship in developed countries. Given current concerns with the increasing frequency and magnitude of droughts in many regions of the world, especially in the light of expected climate change, drought monitoring and dissemination of early warning information in a timely fashion on a global scale is a critical concern as an important adaptation and mitigation strategy. While a number of nations, and a few continental-scale activities have developed drought information system activities, a global drought early warning system (GDEWS) remains elusive, despite the benefits highlighted by ministers to the Global Earth Observation System of System in 2008. In an effort to begin a process of drought monitoring with international collaboration, the National Integrated Drought Information System's (NIDIS) U.S. Drought Portal, a web-based information system created to address drought services and early warning in the United States, including drought monitoring, forecasting, impacts, mitigation, research, and education, volunteered to develop a prototype Global Drought Monitoring Portal (GDMP). Through integration of data and information at the global level, and with four continental-level partners, the GDMP has proven successful as a tool to monitor drought around the globe. At a past meeting between NIDIS, the World Meteorological Organization, and the Global Earth Observation System of Systems, it was recommended that the GDMP form the basis for a Global Drought Information System (GDIS). Currently, GDIS activities are focused around providing operational global drought monitoring products and assessments, incorporating additional drought monitoring information, especially from those areas without regional or continental-scale input, and incorporating drought-specific climate forecast information from the World Climate Research Programme. Additional GDIS pilot activities are underway with an emphasis on information and decision making, and how to effectively provide drought early warning. This talk will provide an update on the status of GDIS and its role in international drought monitoring.

  3. Remote Blood Glucose Monitoring in mHealth Scenarios: A Review.

    PubMed

    Lanzola, Giordano; Losiouk, Eleonora; Del Favero, Simone; Facchinetti, Andrea; Galderisi, Alfonso; Quaglini, Silvana; Magni, Lalo; Cobelli, Claudio

    2016-11-24

    Glucose concentration in the blood stream is a critical vital parameter and an effective monitoring of this quantity is crucial for diabetes treatment and intensive care management. Effective bio-sensing technology and advanced signal processing are therefore of unquestioned importance for blood glucose monitoring. Nevertheless, collecting measurements only represents part of the process as another critical task involves delivering the collected measures to the treating specialists and caregivers. These include the clinical staff, the patient's significant other, his/her family members, and many other actors helping with the patient treatment that may be located far away from him/her. In all of these cases, a remote monitoring system, in charge of delivering the relevant information to the right player, becomes an important part of the sensing architecture. In this paper, we review how the remote monitoring architectures have evolved over time, paralleling the progress in the Information and Communication Technologies, and describe our experiences with the design of telemedicine systems for blood glucose monitoring in three medical applications. The paper ends summarizing the lessons learned through the experiences of the authors and discussing the challenges arising from a large-scale integration of sensors and actuators.

  4. Remote Blood Glucose Monitoring in mHealth Scenarios: A Review

    PubMed Central

    Lanzola, Giordano; Losiouk, Eleonora; Del Favero, Simone; Facchinetti, Andrea; Galderisi, Alfonso; Quaglini, Silvana; Magni, Lalo; Cobelli, Claudio

    2016-01-01

    Glucose concentration in the blood stream is a critical vital parameter and an effective monitoring of this quantity is crucial for diabetes treatment and intensive care management. Effective bio-sensing technology and advanced signal processing are therefore of unquestioned importance for blood glucose monitoring. Nevertheless, collecting measurements only represents part of the process as another critical task involves delivering the collected measures to the treating specialists and caregivers. These include the clinical staff, the patient’s significant other, his/her family members, and many other actors helping with the patient treatment that may be located far away from him/her. In all of these cases, a remote monitoring system, in charge of delivering the relevant information to the right player, becomes an important part of the sensing architecture. In this paper, we review how the remote monitoring architectures have evolved over time, paralleling the progress in the Information and Communication Technologies, and describe our experiences with the design of telemedicine systems for blood glucose monitoring in three medical applications. The paper ends summarizing the lessons learned through the experiences of the authors and discussing the challenges arising from a large-scale integration of sensors and actuators. PMID:27886122

  5. Multisensor system for the protection of critical infrastructure of a seaport

    NASA Astrophysics Data System (ADS)

    Kastek, Mariusz; Dulski, Rafał; Zyczkowski, Marek; Szustakowski, Mieczysław; Trzaskawka, Piotr; Ciurapinski, Wiesław; Grelowska, Grazyna; Gloza, Ignacy; Milewski, Stanislaw; Listewnik, Karol

    2012-06-01

    There are many separated infrastructural objects within a harbor area that may be considered "critical", such as gas and oil terminals or anchored naval vessels. Those objects require special protection, including security systems capable of monitoring both surface and underwater areas, because an intrusion into the protected area may be attempted using small surface vehicles (boats, kayaks, rafts, floating devices with weapons and explosives) as well as underwater ones (manned or unmanned submarines, scuba divers). The paper will present the concept of multisensor security system for a harbor protection, capable of complex monitoring of selected critical objects within the protected area. The proposed system consists of a command centre and several different sensors deployed in key areas, providing effective protection from land and sea, with special attention focused on the monitoring of underwater zone. The initial project of such systems will be presented, its configuration and initial tests of the selected components. The protection of surface area is based on medium-range radar and LLTV and infrared cameras. Underwater zone will be monitored by a sonar and acoustic and magnetic barriers, connected into an integrated monitoring system. Theoretical analyses concerning the detection of fast, small surface objects (such as RIB boats) by a camera system and real test results in various weather conditions will also be presented.

  6. Fitting Community Based Newborn Care Package into the health systems of Nepal.

    PubMed

    Pradhan, Y V; Upreti, S R; Kc, N P; Thapa, K; Shrestha, P R; Shedain, P R; Dhakwa, J R; Aryal, D R; Aryal, S; Paudel, D C; Paudel, D; Khanal, S; Bhandari, A; Kc, A

    2011-10-01

    Community-based strategies for delivering effective newborn interventions are an essential step to avert newborn death, in settings where the health facilities are unable to effectively deliver the interventions and reach their population. Effective implementation of community-based interventions as a large scale program and within the existing health system depends on the appropriate design and planning, monitoring and support systems. This article provides an overview of implementation design of Community-Based Newborn Care Package (CB-NCP) program, its setup within the health system, and early results of the implementation from one of the pilot districts. The evaluation of CB-NCP in one of the pilot districts shows significant improvement in antenatal, intrapartum and post natal care. The implementation design of the CB-NCP has six different health system management functions: i) district planning and orientation, ii) training/human resource development, iii) monitoring and evaluation, iv) logistics and supply chain management, v) communication strategy, and vi) pay for performance. The CB-NCP program embraced the existing system of monitoring with some additional components for the pilot phase to test implementation feasibility, and aligns with existing safe motherhood and child health programs. Though CB-NCP interventions are proven independently in different local and global contexts, they are piloted in 10 districts as a "package" within the national health system settings of Nepal.

  7. Cost-utility analysis of the EVOLVO study on remote monitoring for heart failure patients with implantable defibrillators: randomized controlled trial.

    PubMed

    Zanaboni, Paolo; Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-05-30

    Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Two hundred patients implanted with a wireless transmission-enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f).

  8. Monitoring regional effects of high pressure injection of wastewater in a limestone aquifer

    USGS Publications Warehouse

    Faulkner, Glen L.; Pascale, Charles A.

    1975-01-01

    More than 10 billion gallons (38 × 106 m3) of acid industrial liquid waste has been injected in about 11 years under high pressure into a saline-water-filled part of a limestone aquifer of low transmissivity between 1,400 and 1,700 feet (430 and 520 m) below land surface near Pensacola, Florida. A similar waste disposal system is planned for the same zone at a site about 8.5 miles (13.7 km) to the east. The injection zone is the lower limestone of the Floridan aquifer. The lower limestone is overlain by a confining layer of plastic clay about 220 feet (67 m) thick at the active injection site and underlain by another confining layer of shale and clay. The upper confining layer is overlain by the upper limestone of the Floridan aquifer.The active injection system consists of two injection wells about a quarter of a mile (0.4 km) apart and three monitor wells. Two of the monitor wells (deep monitors) are used to observe hydraulic and geochemical effects of waste injection in the injection zone at locations about 1.5 miles (2.4 km) south and 1.9 miles (3.1 km) north of the center of the injection site. The third well (shallow monitor), used to observe any effects in the upper limestone, is about 100 feet (30 m) from one of the injection wells. Since 1972 the injection zone has also been monitored at a test well at the planned new injection site. Three more monitor wells in the injection zone were activated in early 1974 at sites 17 miles (27 km) northeast, 22 miles (35 km) east and 33 miles (53 km) northeast of the injection site. The six deep monitors provide a system for evaluating the regional effects of injecting wastes. No change in pressure or water quality due to injection was, by mid-1974, evident in the upper limestone at the injection site, but static pressures in the lower limestone at the site had increased 8 fold since injection began in 1963. Chemical analyses indicated probable arrival of the diluted waste at the south monitor well in 1973. By mid-1974 waste evidently had not reached the north monitor well.Calculations indicate that by mid-1974 pressure effects from waste injection extended radially more than 40 miles (64 km) from the injection site. By mid-1974 pressure effects of injection were evident from water-level measurements made at the five deep monitor wells nearest the active injection site. No effects were recognized at the well 33 miles (53 km) away. Less than 20 miles (32 km) northeast of the active injection site, the lower limestone contains fresh water. Changes in the pressure regime due to injection indicate a tendency for northeastward movement of the fresh-water/salt-water interface in the lower limestone.

  9. An Environment for Guideline-based Decision Support Systems for Outpatients Monitoring.

    PubMed

    Zini, Elisa M; Lanzola, Giordano; Bossi, Paolo; Quaglini, Silvana

    2017-08-11

    We propose an architecture for monitoring outpatients that relies on mobile technologies for acquiring data. The goal is to better control the onset of possible side effects between the scheduled visits at the clinic. We analyze the architectural components required to ensure a high level of abstraction from data. Clinical practice guidelines were formalized with Alium, an authoring tool based on the PROforma language, using SNOMED-CT as a terminology standard. The Alium engine is accessible through a set of APIs that may be leveraged for implementing an application based on standard web technologies to be used by doctors at the clinic. Data sent by patients using mobile devices need to be complemented with those already available in the Electronic Health Record to generate personalized recommendations. Thus a middleware pursuing data abstraction is required. To comply with current standards, we adopted the HL7 Virtual Medical Record for Clinical Decision Support Logical Model, Release 2. The developed architecture for monitoring outpatients includes: (1) a guideline-based Decision Support System accessible through a web application that helps the doctors with prevention, diagnosis and treatment of therapy side effects; (2) an application for mobile devices, which allows patients to regularly send data to the clinic. In order to tailor the monitoring procedures to the specific patient, the Decision Support System also helps physicians with the configuration of the mobile application, suggesting the data to be collected and the associated collection frequency that may change over time, according to the individual patient's conditions. A proof of concept has been developed with a system for monitoring the side effects of chemo-radiotherapy in head and neck cancer patients. Our environment introduces two main innovation elements with respect to similar works available in the literature. First, in order to meet the specific patients' needs, in our work the Decision Support System also helps the physicians in properly configuring the mobile application. Then the Decision Support System is also continuously fed by patient-reported outcomes.

  10. Multimodal activity monitoring for home rehabilitation of geriatric fracture patients--feasibility and acceptance of sensor systems in the GAL-NATARS study.

    PubMed

    Marschollek, Michael; Becker, Marcus; Bauer, Jürgen M; Bente, Petra; Dasenbrock, Lena; Elbers, Katharina; Hein, Andreas; Kolb, Gerald; Künemund, Harald; Lammel-Polchau, Christopher; Meis, Markus; Meyer Zu Schwabedissen, Hubertus; Remmers, Hartmut; Schulze, Mareike; Steen, Enno-Edzard; Thoben, Wilfried; Wang, Ju; Wolf, Klaus-Hendrik; Haux, Reinhold

    2014-01-01

    Demographic change will lead to a diminishing care workforce faced with rising numbers of older persons in need of care, suggesting meaningful use of health-enabling technologies, and home monitoring in particular, to contribute to supporting both the carers and the persons in need. We present and discuss the GAL-NATARS study design along with first results regarding technical feasibility of long-term home monitoring and acceptance of different sensor modalities. Fourteen geriatric participants with mobility-impairing fractures were recruited in three geriatric clinics. Following inpatient geriatric rehabilitation, their homes were equipped with ambient sensor components for three months. Additionally, a wearable accelerometer was employed. Technical feasibility was assessed by system and component downtimes, technology acceptance by face-to-face interviews. The overall system downtime was 6%, effected by two single events, but not by software failures. Technology acceptance was rated very high by all participants at the end of the monitoring periods, and no interference with their social lives was reported. Home-monitoring technologies were well-accepted by our participants. The information content of the data still needs to be evaluated with regard to clinical outcome parameters as well as the effect on the quality of life before recommending large-scale implementations.

  11. Transcutaneous blood glucose monitoring system based on an ISFET glucose sensor and studies on diabetic patients.

    PubMed

    Ito, N; Saito, A; Kayashima, S; Kimura, J; Kuriyama, T; Nagata, N; Arai, T; Kikuchi, M

    1995-01-01

    A transcutaneous blood glucose monitoring system consists of an ion-sensitive field-effect transistor (ISFET) glucose sensor unit and a suction effusion fluid (SEF) collecting unit. The SEF is directly collected by a weak suction (400 mmHg absolute pressure) through the skin from which the corneum layer of the epidermis has been previously removed. An ISFET glucose sensor unit is able to measure glucose concentrations in a microliter order sampling volume. The system was applied to three diabetic patients during a 75 g oral glucose tolerance test for monitoring blood glucose levels. During the experiments, glucose changes in the SEF followed actual blood glucose levels with 10 min delays. Results suggest the feasibility of utilizing quasi-continuous, transcutaneous blood glucose monitoring for individual patients with various diabetic histories or diabetic complications.

  12. Integrating modeling, monitoring, and management to reduce critical uncertainties in water resource decision making.

    PubMed

    Peterson, James T; Freeman, Mary C

    2016-12-01

    Stream ecosystems provide multiple, valued services to society, including water supply, waste assimilation, recreation, and habitat for diverse and productive biological communities. Managers striving to sustain these services in the face of changing climate, land uses, and water demands need tools to assess the potential effectiveness of alternative management actions, and often, the resulting tradeoffs between competing objectives. Integrating predictive modeling with monitoring data in an adaptive management framework provides a process by which managers can reduce model uncertainties and thus improve the scientific bases for subsequent decisions. We demonstrate an integration of monitoring data with a dynamic, metapopulation model developed to assess effects of streamflow alteration on fish occupancy in a southeastern US stream system. Although not extensive (collected over three years at nine sites), the monitoring data allowed us to assess and update support for alternative population dynamic models using model probabilities and Bayes rule. We then use the updated model weights to estimate the effects of water withdrawal on stream fish communities and demonstrate how feedback in the form of monitoring data can be used to improve water resource decision making. We conclude that investment in more strategic monitoring, guided by a priori model predictions under alternative hypotheses and an adaptive sampling design, could substantially improve the information available to guide decision-making and management for ecosystem services from lotic systems. Published by Elsevier Ltd.

  13. Unmanned aerial vehicle acquisition of three-dimensional digital image correlation measurements for structural health monitoring of bridges

    NASA Astrophysics Data System (ADS)

    Reagan, Daniel; Sabato, Alessandro; Niezrecki, Christopher

    2017-04-01

    Civil engineering structures such as bridges, buildings, and tunnels continue to be used despite aging and deterioration well past their design life. In 2013, the American Society of Civil Engineers (ASCE) rated the state of the U.S. bridges as mediocre, despite the $12.8 billion USD annually invested. Traditional inspection and monitoring techniques may produce inconsistent results, are labor intensive and too time-consuming to be considered effective for large-scale monitoring. Therefore, new structural health monitoring systems must be developed that are automated, highly accurate, minimally invasive, and cost effective. Three-dimensional (3D) digital image correlation (DIC) systems possess the capability of extracting full-field strain, displacement, and geometry profiles. Furthermore, as this measurement technique is implemented within an Unmanned Aerial Vehicle (UAV) the capability to expedite the optical-based measurement process is increased as well as the infrastructure downtime being reduced. These resulting integrity maps of the structure of interest can be easily interpreted by trained personal. Within this paper, the feasibility of performing DIC measurements using a pair of cameras installed on a UAV is shown. Performance is validated with in-flight measurements. Also, full-field displacement monitoring, 3D measurement stitching, and 3D point-tracking techniques are employed in conjunction with 3D mapping and data management software. The results of these experiments show that the combination of autonomous flight with 3D DIC and other non-contact measurement systems provides a highly valuable and effective civil inspection platform.

  14. Implementation of a computer-assisted monitoring system for the detection of adverse drug reactions in gastroenterology.

    PubMed

    Dormann, H; Criegee-Rieck, M; Neubert, A; Egger, T; Levy, M; Hahn, E G; Brune, K

    2004-02-01

    To investigate the effectiveness of a computer monitoring system that detects adverse drug reactions (ADRs) by laboratory signals in gastroenterology. A prospective, 6-month, pharmaco-epidemiological survey was carried out on a gastroenterological ward at the University Hospital Erlangen-Nuremberg. Two methods were used to identify ADRs. (i) All charts were reviewed daily by physicians and clinical pharmacists. (ii) A computer monitoring system generated a daily list of automatic laboratory signals and alerts of ADRs, including patient data and dates of events. One hundred and nine ADRs were detected in 474 admissions (377 patients). The computer monitoring system generated 4454 automatic laboratory signals from 39 819 laboratory parameters tested, and issued 2328 alerts, 914 (39%) of which were associated with ADRs; 574 (25%) were associated with ADR-positive admissions. Of all the alerts generated, signals of hepatotoxicity (1255), followed by coagulation disorders (407) and haematological toxicity (207), were prevalent. Correspondingly, the prevailing ADRs were concerned with the metabolic and hepato-gastrointestinal system (61). The sensitivity was 91%: 69 of 76 ADR-positive patients were indicated by an alert. The specificity of alerts was increased from 23% to 76% after implementation of an automatic laboratory signal trend monitoring algorithm. This study shows that a computer monitoring system is a useful tool for the systematic and automated detection of ADRs in gastroenterological patients.

  15. EMIR: a configurable hierarchical system for event monitoring and incident response

    NASA Astrophysics Data System (ADS)

    Deich, William T. S.

    2014-07-01

    The Event Monitor and Incident Response system (emir) is a flexible, general-purpose system for monitoring and responding to all aspects of instrument, telescope, and general facility operations, and has been in use at the Automated Planet Finder telescope for two years. Responses to problems can include both passive actions (e.g. generating alerts) and active actions (e.g. modifying system settings). Emir includes a monitor-and-response daemon, plus graphical user interfaces and text-based clients that automatically configure themselves from data supplied at runtime by the daemon. The daemon is driven by a configuration file that describes each condition to be monitored, the actions to take when the condition is triggered, and how the conditions are aggregated into hierarchical groups of conditions. Emir has been implemented for the Keck Task Library (KTL) keyword-based systems used at Keck and Lick Observatories, but can be readily adapted to many event-driven architectures. This paper discusses the design and implementation of Emir , and the challenges in balancing the competing demands for simplicity, flexibility, power, and extensibility. Emir 's design lends itself well to multiple purposes, and in addition to its core monitor and response functions, it provides an effective framework for computing running statistics, aggregate values, and summary state values from the primitive state data generated by other subsystems, and even for creating quick-and-dirty control loops for simple systems.

  16. Purge water management system

    DOEpatents

    Cardoso-Neto, J.E.; Williams, D.W.

    1995-01-01

    A purge water management system is described for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

  17. Purge water management system

    DOEpatents

    Cardoso-Neto, Joao E.; Williams, Daniel W.

    1996-01-01

    A purge water management system for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.

  18. Monitoring technologies for the evaluation of a Soil-Aquifer-Treatment system in coastal aquifer environments.

    NASA Astrophysics Data System (ADS)

    Kallioras, Andreas; Tsertou, Athanasia; Foglia, Laura; Bumberger, Jan; Vienken, Thomas; Dietrich, Peter; Schüth, Christoph

    2014-05-01

    Artificial recharge of groundwater has an important role to play in water reuse. Treated sewage effluent can be infiltrated into the ground for recharge of aquifers. As the effluent water moves through the soil and the aquifer, it undergoes significant quality improvements through physical, chemical, and biological processes in the underground environment. Collectively, these processes and the water quality improvement obtained are called soil-aquifer-treatment (SAT) or geopurification. Recharge systems for SAT can be designed as infiltration-recovery systems, where all effluent water is recovered as such from the aquifer, or after blending with native groundwater. SAT typically removes essentially all suspended solids, biochemical oxygen demand (BOD), and pathogens (viruses, bacteria, protozoa, and helminthic eggs). Concentrations of synthetic organic carbon, phosphorous, and heavy metals are greatly reduced. The pilot site of LTCP will involve the employment of infiltration basins, which will be using waters of impaired quality as a recharge source, and hence acting as a Soil-Aquifer-Treatment, SAT, system. T he LTCP site will be employed as a pilot SAT system complemented by new technological developments, which will be providing continuous monitoring of the quantitative and qualitative characteristics of infiltrating groundwater through all hydrologic zones (i.e. surface, unsaturated and saturated zone). This will be achieved through the development and installation of an integrated system of prototype sensors, installed on-site, and offering a continuous evaluation of the performance of the SAT system. An integrated approach of the performance evaluation of any operating SAT system should aim at parallel monitoring of all hydrologic zones, proving the sustainability of all involved water quality treatment processes within unsaturated and saturated zone. Hence a prototype system of Time Domain Reflectometry (TDR) sensors will be developed, in order to achieve continuous quantitative monitoring of the unsaturated zone through the entire soil column down to significant depths below the SAT basin. The above technique will offer continuous monitoring of infiltration rates and possible mechanical clogging effects. The qualitative monitoring of the unsaturated zone will be achieved through the installation of appropriate pore-water samplers within a multi-level basis, ensuring repeatability of sampling of infiltrating water of impaired quality. This study also involves the qualitative and quantitative assessment of the Lavrion multi-aquifer system through continuous monitoring of the performance of (i) the alluvial aquifer and its potential for additional water treatment as well as (ii) the effects of the SAT system for countermeasuring seawater intrusion in the area of Lavrion. Additionally, setup and calibration of numerical flow and transport models for evaluating and optimizing different operational modes of the SAT system within both saturated and unsaturated zones will be conducted. The monitoring system will be connected to an ad-hoc wireless network for continuous data transfer within the SAT facilities. It is envisaged that the development and combined application of all the above technologies will provide an integrated monitoring platform for the evaluation of SAT system performance.

  19. Environment quality monitoring using ARM processor

    NASA Astrophysics Data System (ADS)

    Vinaya, C. H.; Krishna Thanikanti, Vamsi; Ramasamy, Sudha

    2017-11-01

    This paper of air quality monitoring system describes a model of sensors network to continuously monitoring the environment with low cost developed model. At present time all over the world turned into a great revolution in industrial domain and on the other hand environment get polluting in a dangerous value. There are so many technologies present to reduce the polluting contents but still there is no completely reduction of that pollution. Even there are different methods to monitor the pollution content; these are much costly that not everyone can adapt those methods or devices. Now we are proposing a sensors connected network to monitor the environment continuously and displaying the pollutant gases percentage in air surroundings and can transmit the results to our mobiles by message. The advantage of this system is easy to design, establish at area to monitor, maintenance and most cost effective as well.

  20. 46 CFR 161.002-4 - General requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... vibration and the adverse effects of sea humidity. (b) Standards. (1) All fire-protective systems must be... systems. (3) All parts of the system must pass the environmental tests for control and monitoring...

  1. 46 CFR 161.002-4 - General requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... vibration and the adverse effects of sea humidity. (b) Standards. (1) All fire-protective systems must be... systems. (3) All parts of the system must pass the environmental tests for control and monitoring...

  2. 46 CFR 161.002-4 - General requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... vibration and the adverse effects of sea humidity. (b) Standards. (1) All fire-protective systems must be... systems. (3) All parts of the system must pass the environmental tests for control and monitoring...

  3. 46 CFR 161.002-4 - General requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... vibration and the adverse effects of sea humidity. (b) Standards. (1) All fire-protective systems must be... systems. (3) All parts of the system must pass the environmental tests for control and monitoring...

  4. Factors affecting mobile diabetes monitoring adoption among physicians: questionnaire study and path model.

    PubMed

    Okazaki, Shintaro; Castañeda, José Alberto; Sanz, Silvia; Henseler, Jörg

    2012-12-21

    Patients with type 1 and type 2 diabetes often find it difficult to control their blood glucose level on a daily basis because of distance or physical incapacity. With the increase in Internet-enabled smartphone use, this problem can be resolved by adopting a mobile diabetes monitoring system. Most existing studies have focused on patients' usability perceptions, whereas little attention has been paid to physicians' intentions to adopt this technology. The aim of the study was to evaluate the perceptions and user acceptance of mobile diabetes monitoring among Japanese physicians. A questionnaire survey of physicians was conducted in Japan. The structured questionnaire was prepared in a context of a mobile diabetes monitoring system that controls blood glucose, weight, physical activity, diet, insulin and medication, and blood pressure. Following a thorough description of mobile diabetes monitoring with a graphical image, questions were asked relating to system quality, information quality, service quality, health improvement, ubiquitous control, privacy and security concerns, perceived value, subjective norms, and intention to use mobile diabetes monitoring. The data were analyzed by partial least squares (PLS) path modeling. In total, 471 physicians participated from 47 prefectures across Japan, of whom 134 were specialized in internal and gastrointestinal medicine. Nine hypotheses were tested with both the total sample and the specialist subsample; results were similar for both samples in terms of statistical significance and the strength of path coefficients. We found that system quality, information quality, and service quality significantly affect overall quality. Overall quality determines the extent to which physicians perceive the value of mobile health monitoring. However, in contrast to our initial predictions, overall quality does not have a significant direct effect on the intention to use mobile diabetes monitoring. With regard to net benefits, both ubiquitous control and health improvement are significant predictors. Net benefits in turn significantly motivate physicians to use mobile health monitoring, and has a strong influence on perceived value. Perceived value and subjective norms are predictors of intention to use. In our sample, concerns over privacy and security risk have no significant effects on intention to use mobile diabetes monitoring. Among the 3 control variables, only age significantly affected intention to use mobile diabetes monitoring, whereas experience and gender were not significant predictors of intention. Physicians consider perceived value and net benefits as the most important motivators to use mobile diabetes monitoring. Overall quality assessment does affect their intention to use this technology, but only indirectly through perceived value. Net benefits seem to be a strong driver in both a direct and indirect manner, implying that physicians may perceive health improvement with ubiquitous control as a true utility by enhancing cost-effective monitoring, and simultaneously recognize it as a way to create value for their clinical practices.

  5. Automation trust and attention allocation in multitasking workspace.

    PubMed

    Karpinsky, Nicole D; Chancey, Eric T; Palmer, Dakota B; Yamani, Yusuke

    2018-07-01

    Previous research suggests that operators with high workload can distrust and then poorly monitor automation, which has been generally inferred from automation dependence behaviors. To test automation monitoring more directly, the current study measured operators' visual attention allocation, workload, and trust toward imperfect automation in a dynamic multitasking environment. Participants concurrently performed a manual tracking task with two levels of difficulty and a system monitoring task assisted by an unreliable signaling system. Eye movement data indicate that operators allocate less visual attention to monitor automation when the tracking task is more difficult. Participants reported reduced levels of trust toward the signaling system when the tracking task demanded more focused visual attention. Analyses revealed that trust mediated the relationship between the load of the tracking task and attention allocation in Experiment 1, an effect that was not replicated in Experiment 2. Results imply a complex process underlying task load, visual attention allocation, and automation trust during multitasking. Automation designers should consider operators' task load in multitasking workspaces to avoid reduced automation monitoring and distrust toward imperfect signaling systems. Copyright © 2018. Published by Elsevier Ltd.

  6. A Smartphone-Based Driver Safety Monitoring System Using Data Fusion

    PubMed Central

    Lee, Boon-Giin; Chung, Wan-Young

    2012-01-01

    This paper proposes a method for monitoring driver safety levels using a data fusion approach based on several discrete data types: eye features, bio-signal variation, in-vehicle temperature, and vehicle speed. The driver safety monitoring system was developed in practice in the form of an application for an Android-based smartphone device, where measuring safety-related data requires no extra monetary expenditure or equipment. Moreover, the system provides high resolution and flexibility. The safety monitoring process involves the fusion of attributes gathered from different sensors, including video, electrocardiography, photoplethysmography, temperature, and a three-axis accelerometer, that are assigned as input variables to an inference analysis framework. A Fuzzy Bayesian framework is designed to indicate the driver’s capability level and is updated continuously in real-time. The sensory data are transmitted via Bluetooth communication to the smartphone device. A fake incoming call warning service alerts the driver if his or her safety level is suspiciously compromised. Realistic testing of the system demonstrates the practical benefits of multiple features and their fusion in providing a more authentic and effective driver safety monitoring. PMID:23247416

  7. Can airborne ultrasound monitor bubble size in chocolate?

    NASA Astrophysics Data System (ADS)

    Watson, N.; Hazlehurst, T.; Povey, M.; Vieira, J.; Sundara, R.; Sandoz, J.-P.

    2014-04-01

    Aerated chocolate products consist of solid chocolate with the inclusion of bubbles and are a popular consumer product in many countries. The volume fraction and size distribution of the bubbles has an effect on their sensory properties and manufacturing cost. For these reasons it is important to have an online real time process monitoring system capable of measuring their bubble size distribution. As these products are eaten by consumers it is desirable that the monitoring system is non contact to avoid food contaminations. In this work we assess the feasibility of using an airborne ultrasound system to monitor the bubble size distribution in aerated chocolate bars. The experimental results from the airborne acoustic experiments were compared with theoretical results for known bubble size distributions using COMSOL Multiphysics. This combined experimental and theoretical approach is used to develop a greater understanding of how ultrasound propagates through aerated chocolate and to assess the feasibility of using airborne ultrasound to monitor bubble size distribution in these systems. The results indicated that a smaller bubble size distribution would result in an increase in attenuation through the product.

  8. Design of power cable grounding wire anti-theft monitoring system

    NASA Astrophysics Data System (ADS)

    An, Xisheng; Lu, Peng; Wei, Niansheng; Hong, Gang

    2018-01-01

    In order to prevent the serious consequences of the power grid failure caused by the power cable grounding wire theft, this paper presents a GPRS based power cable grounding wire anti-theft monitoring device system, which includes a camera module, a sensor module, a micro processing system module, and a data monitoring center module, a mobile terminal module. Our design utilize two kinds of methods for detecting and reporting comprehensive image, it can effectively solve the problem of power and cable grounding wire box theft problem, timely follow-up grounded cable theft events, prevent the occurrence of electric field of high voltage transmission line fault, improve the reliability of the safe operation of power grid.

  9. Laser heterodyne detection techniques. [for atmospheric monitoring applications

    NASA Technical Reports Server (NTRS)

    Menzies, R. T.

    1976-01-01

    The principles of heterodyne radiometry are examined, taking into account thermal radiation, the Dicke microwave radiometer, photomixing in the infrared, and signal-to-noise considerations. The passive heterodyne radiometer is considered and a description is presented of heterodyne techniques in active monitoring systems. Attention is given to gas emissivities in the infrared, component requirements, experimental heterodyne detection of gases, a comparison of the passive heterodyne radiometer with the Michelson interferometer-spectrometer, airborne monitoring applications, turbulence effects on passive heterodyne radiometry, sensitivity improvements with heterodyning, atmosphere-induced degradation of bistatic system performance, pollutant detection experiments with a bistatic system, and the airborne laser absorption spectrometer. Future improvements in spectral flexibility are also discussed.

  10. Method for monitoring environmental and corrosion

    DOEpatents

    Glass, Robert S.; Clarke, Jr., Willis L.; Ciarlo, Dino R.

    1995-01-01

    A corrosion sensor array incorporating individual elements for measuring various elements and ions, such as chloride, sulfide, copper, hydrogen (pH), etc. and elements for evaluating the instantaneous corrosion properties of structural materials. The exact combination and number of elements measured or monitored would depend upon the environmental conditions and materials used which are subject to corrosive effects. Such a corrosion monitoring system embedded in or mounted on a structure exposed to the environment would serve as an early warning system for the onset of severe corrosion problems for the structure, thus providing a safety factor as well as economic factors. The sensor array is accessed to an electronics/computational system, which provides a means for data collection and analysis.

  11. Sensors for Environmental Control

    NASA Technical Reports Server (NTRS)

    1996-01-01

    Under a Kennedy Space Center Small Business Innovation Research contract, GEO-CENTERS, Inc. developed a sensing element or 'optrode,' which NASA needed for space life support research to measure a hydroponic culture's pH factor. The company then commercialized the technology in the PC Based pH Monitoring System. The system employs the optrode to enable long term continuous monitoring of the pH level of fluids in standing and flowing conditions, an optoelectronic board with light sensors and detectors that fits into a desktop computer, and a fiber optic cable that connects the two. The system is effective in monitoring the pH output of industries to maintain ranges acceptable to the Environmental Protection Agency.

  12. A mobile and web-based clinical decision support and monitoring system for diabetes mellitus patients in primary care: a study protocol for a randomized controlled trial.

    PubMed

    Kart, Özge; Mevsim, Vildan; Kut, Alp; Yürek, İsmail; Altın, Ayşe Özge; Yılmaz, Oğuz

    2017-11-29

    Physicians' guideline use rates for diagnosis, treatment and monitoring of diabetes mellitus (DM) is very low. Time constraints, patient overpopulation, and complex guidelines require alternative solutions for real time patient monitoring. Rapidly evolving e-health technology combined with clinical decision support and monitoring systems (CDSMS) provides an effective solution to these problems. The purpose of the study is to develop a user-friendly, comprehensive, fully integrated web and mobile-based Clinical Decision Support and Monitoring System (CDSMS) for the screening, diagnosis, treatment, and monitoring of DM diseases which is used by physicians and patients in primary care and to determine the effectiveness of the system. The CDSMS will be based on evidence-based guidelines for DM disease. A web and mobile-based application will be developed in which the physician will remotely monitor patient data through mobile applications in real time. The developed CDSMS will be tested in two stages. In the first stage, the usability, understandability, and adequacy of the application will be determined. Five primary care physicians will use the developed application for at least 16 DM patients. Necessary improvements will be made according to physician feedback. In the second phase, a parallel, single-blind, randomized controlled trial will be implemented. DM diagnosed patients will be recruited for the CDSMS trial by their primary care physicians. Ten physicians and their 439 patients will be involved in the study. Eligible participants will be assigned to intervention and control groups with simple randomization. The significance level will be accepted as p < 0.05. In the intervention group, the system will make recommendations on patient monitoring, diagnosis, and treatment. These recommendations will be implemented at the physician's discretion. Patients in the control group will be treated by physicians according to current DM treatment standards. Patients in both groups will be monitored for 6 months. Patient data will be compared between 0th and 6th month of the study. . Clinical and laboratory outcomes will be assessed in person while others will be self-assessed online. The developed system will be the first of its kind to utilize evidence based guidelines to provide health services to DM patients. ClinicalTrials.gov NCT02917226 . 28 September 2016.

  13. A fully automated health-care monitoring at home without attachment of any biological sensors and its clinical evaluation.

    PubMed

    Motoi, Kosuke; Ogawa, Mitsuhiro; Ueno, Hiroshi; Kuwae, Yutaka; Ikarashi, Akira; Yuji, Tadahiko; Higashi, Yuji; Tanaka, Shinobu; Fujimoto, Toshiro; Asanoi, Hidetsugu; Yamakoshi, Ken-ichi

    2009-01-01

    Daily monitoring of health condition is important for an effective scheme for early diagnosis, treatment and prevention of lifestyle-related diseases such as adiposis, diabetes, cardiovascular diseases and other diseases. Commercially available devices for health care monitoring at home are cumbersome in terms of self-attachment of biological sensors and self-operation of the devices. From this viewpoint, we have been developing a non-conscious physiological monitor installed in a bath, a lavatory, and a bed for home health care and evaluated its measurement accuracy by simultaneous recordings of a biological sensors directly attached to the body surface. In order to investigate its applicability to health condition monitoring, we have further developed a new monitoring system which can automatically monitor and store the health condition data. In this study, by evaluation on 3 patients with cardiac infarct or sleep apnea syndrome, patients' health condition such as body and excretion weight in the toilet and apnea and hypopnea during sleeping were successfully monitored, indicating that the system appears useful for monitoring the health condition during daily living.

  14. An Overview of the NASA Aviation Safety Program Propulsion Health Monitoring Element

    NASA Technical Reports Server (NTRS)

    Simon, Donald L.

    2000-01-01

    The NASA Aviation Safety Program (AvSP) has been initiated with aggressive goals to reduce the civil aviation accident rate, To meet these goals, several technology investment areas have been identified including a sub-element in propulsion health monitoring (PHM). Specific AvSP PHM objectives are to develop and validate propulsion system health monitoring technologies designed to prevent engine malfunctions from occurring in flight, and to mitigate detrimental effects in the event an in-flight malfunction does occur. A review of available propulsion system safety information was conducted to help prioritize PHM areas to focus on under the AvSP. It is noted that when a propulsion malfunction is involved in an aviation accident or incident, it is often a contributing factor rather than the sole cause for the event. Challenging aspects of the development and implementation of PHM technology such as cost, weight, robustness, and reliability are discussed. Specific technology plans are overviewed including vibration diagnostics, model-based controls and diagnostics, advanced instrumentation, and general aviation propulsion system health monitoring technology. Propulsion system health monitoring, in addition to engine design, inspection, maintenance, and pilot training and awareness, is intrinsic to enhancing aviation propulsion system safety.

  15. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health

    PubMed Central

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-01-01

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient’s cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system. PMID:28353681

  16. A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health.

    PubMed

    Sahoo, Prasan Kumar; Thakkar, Hiren Kumar; Lee, Ming-Yih

    2017-03-29

    Use of information and communication technology such as smart phone, smart watch, smart glass and portable health monitoring devices for healthcare services has made Mobile Health (mHealth) an emerging research area. Coronary Heart Disease (CHD) is considered as a leading cause of death world wide and an increasing number of people die prematurely due to CHD. Under such circumstances, there is a growing demand for a reliable cardiac monitoring system to catch the intermittent abnormalities and detect critical cardiac behaviors which lead to sudden death. Use of mobile devices to collect Electrocardiography (ECG), Seismocardiography (SCG) data and efficient analysis of those data can monitor a patient's cardiac activities for early warning. This paper presents a novel cardiac data acquisition method and combined analysis of Electrocardiography (ECG) and multi channel Seismocardiography (SCG) data. An early warning system is implemented to monitor the cardiac activities of a person and accuracy assessment of the early warning system is conducted for the ECG data only. The assessment shows 88% accuracy and effectiveness of our proposed analysis, which implies the viability and applicability of the proposed early warning system.

  17. Open Source Based Sensor Platform for Mobile Environmental Monitoring and Data Acquisition

    NASA Astrophysics Data System (ADS)

    Schima, Robert; Goblirsch, Tobias; Misterek, René; Salbach, Christoph; Schlink, Uwe; Francyk, Bogdan; Dietrich, Peter; Bumberger, Jan

    2016-04-01

    The impact of global change, urbanization and complex interactions between humans and the environment show different effects on different scales. However, the desire to obtain a better understanding of ecosystems and process dynamics in nature accentuates the need for observing these processes in higher temporal and spatial resolutions. Especially with regard to the process dynamics and heterogeneity of urban areas, a comprehensive monitoring of these effects remains to be a challenging issue. Open source based electronics and cost-effective sensors are offering a promising approach to explore new possibilities of mobile data acquisition and innovative strategies and thereby support a comprehensive ad-hoc monitoring and the capturing of environmental processes close to real time. Accordingly, our project aims the development of new strategies for mobile data acquisition and real-time processing of user-specific environmental data, based on a holistic and integrated process. To this end, the concept of our monitoring system covers the data collection, data processing and data integration as well as the data provision within one infrastructure. This ensures a consistent data stream and a rapid data processing. However, the overarching goal is the provision of an integrated service instead of lengthy and arduous data acquisition by hand. Therefore, the system also serves as a data acquisition assistant and gives guidance during the measurements. In technical terms, our monitoring system consists of mobile sensor devices, which can be controlled and managed by a smart phone app (Android). At the moment, the system is able to acquire temperature and humidity in space (GPS) and time (real-time clock) as a built in function. In addition, larger system functionality can be accomplished by adding further sensors for the detection of e.g. fine dust, methane or dissolved organic compounds. From the IT point of view, the system includes a smart phone app and a web service for data processing, data provision and data visualization. The smart phone app allows the configuration of the mobile sensor devices and provides some built-in functions such as simple data visualization or data transmission via e-mail whereas the web service provides the visualization of the data and tools for data processing. In an initial field experiment, a methane monitoring based on our sensor integration platform was performed in the city area of Leipzig (Germany) in late June 2015. The study has shown that an urban monitoring can be conducted based on open source components. Moreover, the system enabled the detection of hot spots and methane emission sources. In September 2015, a larger scaled city monitoring based on the mobile monitoring platform was performed by five independently driving cyclists through the city center of Leipzig (Germany). As a result we were able to instantly show a heat and humidity map of the inner city center as well as an exposure map for each cyclist. This emphasizes the feasibility and high potential of open source based monitoring approaches for future research in the field of urban area monitoring in general, citizen science or the validation of remote sensing data.

  18. Monitoring iCCM: a feasibility study of the indicator guide for monitoring and evaluating integrated community case management.

    PubMed

    Roberton, Timothy; Kasungami, Dyness; Guenther, Tanya; Hazel, Elizabeth

    2016-07-01

    Most countries in sub-Saharan Africa have now adopted integrated community case management (iCCM) of common childhood illnesses as a strategy to improve child health. In March 2014, the iCCM Task Force published an Indicator Guide for Monitoring and Evaluating iCCM: a 'menu' of recommended indicators with globally agreed definitions and methodology, to guide countries in developing robust iCCM monitoring systems. The Indicator Guide was conceived as an evolving document that would incorporate collective experience and learning as iCCM programmes themselves evolve. This article presents findings from two studies that examined the feasibility of collecting the Indicator Guide's 18 routine monitoring indicators with the iCCM monitoring systems that countries currently have in place. We reviewed iCCM monitoring tools, protocols and reports from a purposive sample of 10 countries in sub-Saharan Africa. We developed a scorecard system to assess which of the Indicator Guide's 18 routine monitoring indicators could be calculated with the given monitoring tools, and at which level of the health system the relevant information would be available. We found that the data needed to calculate many of the Indicator Guide's routine monitoring indicators are already being collected through existing monitoring systems, although much of these data are only available at health facility level and not aggregated to district or national levels. Our results highlight challenge of using supervision checklists as a data source, and the need for countries to maintain accurate deployment data for CHWs and CHW supervisors. We suggest that some of the recommended indicators need revising. Routine monitoring will be more feasible, effective and efficient if iCCM programmes focus on a smaller set of high-value indicators that are easy to measure, reliably interpreted and useful both for global and national stakeholders and for frontline health workers themselves. © The Author 2016. Published by Oxford University Press in association with The London School of Hygiene and Tropical Medicine.

  19. A Mock UF6 Feed and Withdrawal System for Testing Safeguards Monitoring Systems and Strategies Intended for Nuclear Fuel Enrichment and Processing Plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Krichinsky, Alan M; Bates, Bruce E; Chesser, Joel B

    2009-12-01

    This report describes an engineering-scale, mock UF6 feed and withdrawal (F&W) system, its operation, and its intended uses. This system has been assembled to provide a test bed for evaluating and demonstrating new methodologies that can be used in remote, unattended, continuous monitoring of nuclear material process operations. These measures are being investigated to provide independent inspectors improved assurance that operations are being conducted within declared parameters, and to increase the overall effectiveness of safeguarding nuclear material. Testing applicable technologies on a mock F&W system, which uses water as a surrogate for UF6, enables thorough and cost-effective investigation of hardware,more » software, and operational strategies before their direct installation in an industrial nuclear material processing environment. Electronic scales used for continuous load-cell monitoring also are described as part of the basic mock F&W system description. Continuous monitoring components on the mock F&W system are linked to a data aggregation computer by a local network, which also is depicted. Data collection and storage systems are described only briefly in this report. The mock UF{sub 6} F&W system is economical to operate. It uses a simple process involving only a surge tank between feed tanks and product and withdrawal (or waste) tanks. The system uses water as the transfer fluid, thereby avoiding the use of hazardous UF{sub 6}. The system is not tethered to an operating industrial process involving nuclear materials, thereby allowing scenarios (e.g., material diversion) that cannot be conducted otherwise. These features facilitate conducting experiments that yield meaningful results with a minimum of expenditure and quick turnaround time. Technologies demonstrated on the engineering-scale system lead to field trials (described briefly in this report) for determining implementation issues and performance of the monitoring technologies under plant operating conditions. The ultimate use of technologies tested on the engineering-scale test bed is to work with safeguards agencies to install them in operating plants (e.g., enrichment and fuel processing plants), thereby promoting new safeguards measures with minimal impact to operating plants. In addition, this system is useful in identifying features for new plants that can be incorporated as part of 'safeguards by design,' in which load cells and other monitoring technologies are specified to provide outputs for automated monitoring and inspector evaluation.« less

  20. Immunisation Information Systems – useful tools for monitoring vaccination programmes in EU/EEA countries, 2016

    PubMed Central

    Derrough, Tarik; Olsson, Kate; Gianfredi, Vincenza; Simondon, Francois; Heijbel, Harald; Danielsson, Niklas; Kramarz, Piotr; Pastore-Celentano, Lucia

    2017-01-01

    Immunisation Information Systems (IIS) are computerised confidential population based-systems containing individual-level information on vaccines received in a given area. They benefit individuals directly by ensuring vaccination according to the schedule and they provide information to vaccine providers and public health authorities responsible for the delivery and monitoring of an immunisation programme. In 2016, the European Centre for Disease Prevention and Control (ECDC) conducted a survey on the level of implementation and functionalities of IIS in 30 European Union/European Economic Area (EU/EEA) countries. It explored the governance and financial support for the systems, IIS software, system characteristics in terms of population, identification of immunisation recipients, vaccinations received, and integration with other health record systems, the use of the systems for surveillance and programme management as well as the challenges involved with implementation. The survey was answered by 27 of the 30 EU/EEA countries having either a system in production at national or subnational levels (n = 16), or being piloted (n = 5) or with plans for setting up a system in the future (n = 6). The results demonstrate the added-value of IIS in a number of areas of vaccination programme monitoring such as monitoring vaccine coverage at local geographical levels, linking individual immunisation history with health outcome data for safety investigations, monitoring vaccine effectiveness and failures and as an educational tool for both vaccine providers and vaccine recipients. IIS represent a significant way forward for life-long vaccination programme monitoring. PMID:28488999

  1. Immunisation Information Systems - useful tools for monitoring vaccination programmes in EU/EEA countries, 2016.

    PubMed

    Derrough, Tarik; Olsson, Kate; Gianfredi, Vincenza; Simondon, Francois; Heijbel, Harald; Danielsson, Niklas; Kramarz, Piotr; Pastore-Celentano, Lucia

    2017-04-27

    Immunisation Information Systems (IIS) are computerised confidential population based-systems containing individual-level information on vaccines received in a given area. They benefit individuals directly by ensuring vaccination according to the schedule and they provide information to vaccine providers and public health authorities responsible for the delivery and monitoring of an immunisation programme. In 2016, the European Centre for Disease Prevention and Control (ECDC) conducted a survey on the level of implementation and functionalities of IIS in 30 European Union/European Economic Area (EU/EEA) countries. It explored the governance and financial support for the systems, IIS software, system characteristics in terms of population, identification of immunisation recipients, vaccinations received, and integration with other health record systems, the use of the systems for surveillance and programme management as well as the challenges involved with implementation. The survey was answered by 27 of the 30 EU/EEA countries having either a system in production at national or subnational levels (n = 16), or being piloted (n = 5) or with plans for setting up a system in the future (n = 6). The results demonstrate the added-value of IIS in a number of areas of vaccination programme monitoring such as monitoring vaccine coverage at local geographical levels, linking individual immunisation history with health outcome data for safety investigations, monitoring vaccine effectiveness and failures and as an educational tool for both vaccine providers and vaccine recipients. IIS represent a significant way forward for life-long vaccination programme monitoring. This article is copyright of The Authors, 2017.

  2. Development and testing of an artificial arterial and venous pulse oximeter.

    PubMed

    Cloete, G; Fourie, P R; Scheffer, C

    2013-01-01

    The monitoring of patients healthcare is of a prime importance to ensure their efficient and effective treatment. Monitoring blood oxygen saturation is a field which has grown significantly in recent times and more specifically in tissues affected by diseases or conditions that may negatively affect the function of the tissue. This study involved the development and testing of a highly sensitive non-invasive blood oxygen saturation monitoring device. A device that can be used to continuously monitor the condition of tissue affected by diseases which affect the blood flow through the tissue, and the oxygen usage in tissue. The device's system was designed to specifically monitor occluded tissue which has low oxygen saturations and low perfusion. Although with limitted validation the system was unable to accurately measure the venous oxygenation specifically, but it was able to measure the mixed oxygen saturation. With further research it would be possible to validate the system for measuring both the arterial and venous oxygen saturations.

  3. Functionality Enhancement of Industrialized Optical Fiber Sensors and System Developed for Full-Scale Pavement Monitoring

    PubMed Central

    Wang, Huaping; Liu, Wanqiu; He, Jianping; Xing, Xiaoying; Cao, Dandan; Gao, Xipeng; Hao, Xiaowei; Cheng, Hongwei; Zhou, Zhi

    2014-01-01

    Pavements always play a predominant role in transportation. Health monitoring of pavements is becoming more and more significant, as frequently suffering from cracks, rutting, and slippage renders them prematurely out of service. Effective and reliable sensing elements are thus in high demand to make prognosis on the mechanical properties and occurrence of damage to pavements. Therefore, in this paper, various types of functionality enhancement of industrialized optical fiber sensors for pavement monitoring are developed, with the corresponding operational principles clarified in theory and the performance double checked by basic experiments. Furthermore, a self-healing optical fiber sensing network system is adopted to accomplish full-scale monitoring of pavements. The application of optical fiber sensors assembly and self-healing network system in pavement has been carried out to validate the feasibility. It has been proved that the research in this article provides a valuable method and meaningful guidance for the integrity monitoring of civil structures, especially pavements. PMID:24854060

  4. Functionality enhancement of industrialized optical fiber sensors and system developed for full-scale pavement monitoring.

    PubMed

    Wang, Huaping; Liu, Wanqiu; He, Jianping; Xing, Xiaoying; Cao, Dandan; Gao, Xipeng; Hao, Xiaowei; Cheng, Hongwei; Zhou, Zhi

    2014-05-19

    Pavements always play a predominant role in transportation. Health monitoring of pavements is becoming more and more significant, as frequently suffering from cracks, rutting, and slippage renders them prematurely out of service. Effective and reliable sensing elements are thus in high demand to make prognosis on the mechanical properties and occurrence of damage to pavements. Therefore, in this paper, various types of functionality enhancement of industrialized optical fiber sensors for pavement monitoring are developed, with the corresponding operational principles clarified in theory and the performance double checked by basic experiments. Furthermore, a self-healing optical fiber sensing network system is adopted to accomplish full-scale monitoring of pavements. The application of optical fiber sensors assembly and self-healing network system in pavement has been carried out to validate the feasibility. It has been proved that the research in this article provides a valuable method and meaningful guidance for the integrity monitoring of civil structures, especially pavements.

  5. The development and validation of an activity monitoring system for use in measurement of posture of childbearing women during first stage of labor.

    PubMed

    Martin, Caroline J Hollins; Kenney, Laurence; Pratt, Thomas; Granat, Malcolm H

    2015-01-01

    There is limited understanding of the type and extent of maternal postures that midwives should encourage or support during labor. The aims of this study were to identify a set of postures and movements commonly seen during labor, to develop an activity monitoring system for use during labor, and to validate this system design. Volunteer student midwives simulated maternal activity during labor in a laboratory setting. Participants (N = 15) wore monitors adhered to the left thigh and left shank, and adopted 13 common postures of laboring women for 3 minutes each. Simulated activities were recorded using a video camera. Postures and movements were coded from the video, and statistical analysis conducted of agreement between coded video data and outputs of the activity monitoring system. Excellent agreement between the 2 raters of the video recordings was found (Cohen's κ = 0.95). Both sensitivity and specificity of the activity monitoring system were greater than 80% for standing, lying, kneeling, and sitting (legs dangling). This validated system can be used to measure elected activity of laboring women and report on effects of postures on length of first stage, pain experience, birth satisfaction, and neonatal condition. This validated maternal posture-monitoring system is available as a reference-and for use by researchers who wish to develop research in this area. © 2015 by the American College of Nurse-Midwives.

  6. Tools to manage the enterprise-wide picture archiving and communications system environment.

    PubMed

    Lannum, L M; Gumpf, S; Piraino, D

    2001-06-01

    The presentation will focus on the implementation and utilization of a central picture archiving and communications system (PACS) network-monitoring tool that allows for enterprise-wide operations management and support of the image distribution network. The MagicWatch (Siemens, Iselin, NJ) PACS/radiology information system (RIS) monitoring station from Siemens has allowed our organization to create a service support structure that has given us proactive control of our environment and has allowed us to meet the service level performance expectations of the users. The Radiology Help Desk has used the MagicWatch PACS monitoring station as an applications support tool that has allowed the group to monitor network activity and individual systems performance at each node. Fast and timely recognition of the effects of single events within the PACS/RIS environment has allowed the group to proactively recognize possible performance issues and resolve problems. The PACS/operations group performs network management control, image storage management, and software distribution management from a single, central point in the enterprise. The MagicWatch station allows for the complete automation of software distribution, installation, and configuration process across all the nodes in the system. The tool has allowed for the standardization of the workstations and provides a central configuration control for the establishment and maintenance of the system standards. This report will describe the PACS management and operation prior to the implementation of the MagicWatch PACS monitoring station and will highlight the operational benefits of a centralized network and system-monitoring tool.

  7. Development of real-time voltage stability monitoring tool for power system transmission network using Synchrophasor data

    NASA Astrophysics Data System (ADS)

    Pulok, Md Kamrul Hasan

    Intelligent and effective monitoring of power system stability in control centers is one of the key issues in smart grid technology to prevent unwanted power system blackouts. Voltage stability analysis is one of the most important requirements for control center operation in smart grid era. With the advent of Phasor Measurement Unit (PMU) or Synchrophasor technology, real time monitoring of voltage stability of power system is now a reality. This work utilizes real-time PMU data to derive a voltage stability index to monitor the voltage stability related contingency situation in power systems. The developed tool uses PMU data to calculate voltage stability index that indicates relative closeness of the instability by producing numerical indices. The IEEE 39 bus, New England power system was modeled and run on a Real-time Digital Simulator that stream PMU data over the Internet using IEEE C37.118 protocol. A Phasor data concentrator (PDC) is setup that receives streaming PMU data and stores them in Microsoft SQL database server. Then the developed voltage stability monitoring (VSM) tool retrieves phasor measurement data from SQL server, performs real-time state estimation of the whole network, calculate voltage stability index, perform real-time ranking of most vulnerable transmission lines, and finally shows all the results in a graphical user interface. All these actions are done in near real-time. Control centers can easily monitor the systems condition by using this tool and can take precautionary actions if needed.

  8. Construct mine environment monitoring system based on wireless mesh network

    NASA Astrophysics Data System (ADS)

    Chen, Xin; Ge, Gengyu; Liu, Yinmei; Cheng, Aimin; Wu, Jun; Fu, Jun

    2018-04-01

    The system uses wireless Mesh network as a network transmission medium, and strive to establish an effective and reliable underground environment monitoring system. The system combines wireless network technology and embedded technology to monitor the internal data collected in the mine and send it to the processing center for analysis and environmental assessment. The system can be divided into two parts: the main control network module and the data acquisition terminal, and the SPI bus technology is used for mutual communication between them. Multi-channel acquisition and control interface design Data acquisition and control terminal in the analog signal acquisition module, digital signal acquisition module, and digital signal output module. The main control network module running Linux operating system, in which the transplant SPI driver, USB card driver and AODV routing protocol. As a result, the internal data collection and reporting of the mine are realized.

  9. Improved Signal Processing Technique Leads to More Robust Self Diagnostic Accelerometer System

    NASA Technical Reports Server (NTRS)

    Tokars, Roger; Lekki, John; Jaros, Dave; Riggs, Terrence; Evans, Kenneth P.

    2010-01-01

    The self diagnostic accelerometer (SDA) is a sensor system designed to actively monitor the health of an accelerometer. In this case an accelerometer is considered healthy if it can be determined that it is operating correctly and its measurements may be relied upon. The SDA system accomplishes this by actively monitoring the accelerometer for a variety of failure conditions including accelerometer structural damage, an electrical open circuit, and most importantly accelerometer detachment. In recent testing of the SDA system in emulated engine operating conditions it has been found that a more robust signal processing technique was necessary. An improved accelerometer diagnostic technique and test results of the SDA system utilizing this technique are presented here. Furthermore, the real time, autonomous capability of the SDA system to concurrently compensate for effects from real operating conditions such as temperature changes and mechanical noise, while monitoring the condition of the accelerometer health and attachment, will be demonstrated.

  10. METHODS FOR MONITORING THE EFFECTS OF ENVIRONMENTAL TOXINS ON THE VISUAL SYSTEM.

    EPA Science Inventory

    A high percentage of neurotoxic compounds adversely effect the visual system. Our goal is to apply the tools of vision science to problems of toxicological import, exposure-related alterations in visual physiology, psychophysical function, and ocular development. Methods can ...

  11. Ecological monitoring in a discrete-time prey-predator model.

    PubMed

    Gámez, M; López, I; Rodríguez, C; Varga, Z; Garay, J

    2017-09-21

    The paper is aimed at the methodological development of ecological monitoring in discrete-time dynamic models. In earlier papers, in the framework of continuous-time models, we have shown how a systems-theoretical methodology can be applied to the monitoring of the state process of a system of interacting populations, also estimating certain abiotic environmental changes such as pollution, climatic or seasonal changes. In practice, however, there may be good reasons to use discrete-time models. (For instance, there may be discrete cycles in the development of the populations, or observations can be made only at discrete time steps.) Therefore the present paper is devoted to the development of the monitoring methodology in the framework of discrete-time models of population ecology. By monitoring we mean that, observing only certain component(s) of the system, we reconstruct the whole state process. This may be necessary, e.g., when in a complex ecosystem the observation of the densities of certain species is impossible, or too expensive. For the first presentation of the offered methodology, we have chosen a discrete-time version of the classical Lotka-Volterra prey-predator model. This is a minimal but not trivial system where the methodology can still be presented. We also show how this methodology can be applied to estimate the effect of an abiotic environmental change, using a component of the population system as an environmental indicator. Although this approach is illustrated in a simplest possible case, it can be easily extended to larger ecosystems with several interacting populations and different types of abiotic environmental effects. Copyright © 2017 Elsevier Ltd. All rights reserved.

  12. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines.

    PubMed

    Mazur, Katarzyna; Wydra, Michal; Ksiezopolski, Bogdan

    2017-07-11

    Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs) as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Network (WSN) for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs.

  13. SleepSense: A Noncontact and Cost-Effective Sleep Monitoring System.

    PubMed

    Lin, Feng; Zhuang, Yan; Song, Chen; Wang, Aosen; Li, Yiran; Gu, Changzhan; Li, Changzhi; Xu, Wenyao

    2017-02-01

    Quality of sleep is an important indicator of health and well being. Recent developments in the field of in-home sleep monitoring have the potential to enhance a person's sleeping experience and contribute to an overall sense of well being. Existing in-home sleep monitoring devices either fail to provide adequate sleep information or are obtrusive to use. To overcome these obstacles, a noncontact and cost-effective sleep monitoring system, named SleepSense, is proposed for continuous recognition of the sleep status, including on-bed movement, bed exit, and breathing section. SleepSense consists of three parts: a Doppler radar-based sensor, a robust automated radar demodulation module, and a sleep status recognition framework. Herein, several time-domain and frequency-domain features are extracted for the sleep recognition framework. A prototype of SleepSense is presented and evaluated using two sets of experiments. In the short-term controlled experiment, the SleepSense achieves an overall 95.1% accuracy rate in identifying various sleep status. In the 75-minute sleep study, SleepSense demonstrates wide usability in real life. The error rate for breathing rate extraction in this study is only 6.65%. These experimental results indicate that SleepSense is an effective and promising solution for in-home sleep monitoring.

  14. Secure and Time-Aware Communication of Wireless Sensors Monitoring Overhead Transmission Lines

    PubMed Central

    Mazur, Katarzyna; Wydra, Michal; Ksiezopolski, Bogdan

    2017-01-01

    Existing transmission power grids suffer from high maintenance costs and scalability issues along with a lack of effective and secure system monitoring. To address these problems, we propose to use Wireless Sensor Networks (WSNs)as a technology to achieve energy efficient, reliable, and low-cost remote monitoring of transmission grids. With WSNs, smart grid enables both utilities and customers to monitor, predict and manage energy usage effectively and react to possible power grid disturbances in a timely manner. However, the increased application of WSNs also introduces new security challenges, especially related to privacy, connectivity, and security management, repeatedly causing unpredicted expenditures. Monitoring the status of the power system, a large amount of sensors generates massive amount of sensitive data. In order to build an effective Wireless Sensor Networks (WSNs) for a smart grid, we focus on designing a methodology of efficient and secure delivery of the data measured on transmission lines. We perform a set of simulations, in which we examine different routing algorithms, security mechanisms and WSN deployments in order to select the parameters that will not affect the delivery time but fulfill their role and ensure security at the same time. Furthermore, we analyze the optimal placement of direct wireless links, aiming at minimizing time delays, balancing network performance and decreasing deployment costs. PMID:28696390

  15. Automatic Welding System of Aluminum Pipe by Monitoring Backside Image of Molten Pool Using Vision Sensor

    NASA Astrophysics Data System (ADS)

    Baskoro, Ario Sunar; Kabutomori, Masashi; Suga, Yasuo

    An automatic welding system using Tungsten Inert Gas (TIG) welding with vision sensor for welding of aluminum pipe was constructed. This research studies the intelligent welding process of aluminum alloy pipe 6063S-T5 in fixed position and moving welding torch with the AC welding machine. The monitoring system consists of a vision sensor using a charge-coupled device (CCD) camera to monitor backside image of molten pool. The captured image was processed to recognize the edge of molten pool by image processing algorithm. Neural network model for welding speed control were constructed to perform the process automatically. From the experimental results it shows the effectiveness of the control system confirmed by good detection of molten pool and sound weld of experimental result.

  16. A facility monitoring system: The single most valuable and cost-effective tool available to an energy manager

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holmes, W.A.

    Energy engineering and management combines engineering problem-solving and financial management techniques to reduce utility costs. At present, substantial amounts of time and money are being spent in order to attempt to quantify energy consumption and costs and define opportunities for savings. Unfortunately, accurate verification of results is often overlooked. Advances in technology during the last few years have made the installation of a permanent, PC-based monitoring system possible for any facility, often for no more than the cost of a detailed study. By investing initially in a monitoring system rather than audits or studies, the actual consumption and cost datamore » will be available on a continuing basis and can be used to produce immediate operational savings, more accurately analyze opportunities requiring capital investments, and to verify actual savings resulting from changes. A permanent monitoring system, installed as the first step in a utility cost reduction effort, to identify where and how energy is used in a facility on a dynamic and real-time basis, can provide the most valuable and cost-effective tool available to an energy manager. The resulting data allows energy consumption patterns and utility costs to be understood and managed in the same manner as all other costs within a facility.« less

  17. Seven Q-Tracks monitors of laboratory quality drive general performance improvement: experience from the College of American Pathologists Q-Tracks program 1999-2011.

    PubMed

    Meier, Frederick A; Souers, Rhona J; Howanitz, Peter J; Tworek, Joseph A; Perrotta, Peter L; Nakhleh, Raouf E; Karcher, Donald S; Bashleben, Christine; Darcy, Teresa P; Schifman, Ron B; Jones, Bruce A

    2015-06-01

    Many production systems employ standardized statistical monitors that measure defect rates and cycle times, as indices of performance quality. Clinical laboratory testing, a system that produces test results, is amenable to such monitoring. To demonstrate patterns in clinical laboratory testing defect rates and cycle time using 7 College of American Pathologists Q-Tracks program monitors. Subscribers measured monthly rates of outpatient order-entry errors, identification band defects, and specimen rejections; median troponin order-to-report cycle times and rates of STAT test receipt-to-report turnaround time outliers; and critical values reporting event defects, and corrected reports. From these submissions Q-Tracks program staff produced quarterly and annual reports. These charted each subscriber's performance relative to other participating laboratories and aggregate and subgroup performance over time, dividing participants into best and median performers and performers with the most room to improve. Each monitor's patterns of change present percentile distributions of subscribers' performance in relation to monitoring durations and numbers of participating subscribers. Changes over time in defect frequencies and the cycle duration quantify effects on performance of monitor participation. All monitors showed significant decreases in defect rates as the 7 monitors ran variously for 6, 6, 7, 11, 12, 13, and 13 years. The most striking decreases occurred among performers who initially had the most room to improve and among subscribers who participated the longest. All 7 monitors registered significant improvement. Participation effects improved between 0.85% and 5.1% per quarter of participation. Using statistical quality measures, collecting data monthly, and receiving reports quarterly and yearly, subscribers to a comparative monitoring program documented significant decreases in defect rates and shortening of a cycle time for 6 to 13 years in all 7 ongoing clinical laboratory quality monitors.

  18. 8.0 Integrating the effect of terrestrial ecosystem health and land use on the hydrology, habitat, and water quality of the Delaware River and estuary

    Treesearch

    Peter S. Murdoch; John L. Hom; Yude Pan; Jeffrey M. Fischer

    2008-01-01

    To complete the collaborative monitoring study of forested landscapes within the DRB, regional perspective on the cumulative effect of different disturbances on overall ecosystem health. This section describes two modeling activities used as integrating tools for the CEMRI database and a validation system that used nested river monitoring stations.

  19. Development of Field Information Monitoring System Based on the Internet of Things

    NASA Astrophysics Data System (ADS)

    Cai, Ken; Liang, Xiaoying; Wang, Keqiang

    With the rapid development and wide application of electronics, communication and embedded system technologies, the global agriculture is changing from traditional agriculture that is to improve the production relying on the increase of labor, agricultural inputs to the new stage of modern agriculture with low yields, high efficiency, real-time and accuracy. On the other hand the research and development of the Internet of Things, which is an information network to connect objects, with the full capacity to perceive objects, and having the capabilities of reliable transmission and intelligence processing for information, allows us to obtain real-time information of anything. The application of the Internet of Things in field information online monitoring is an effective solution for present wired sensor monitoring system, which has much more disadvantages, such as high cost, the problems of laying lines and so on. In this paper, a novel field information monitoring system based on the Internet of Things is proposed. It can satisfy the requirements of multi-point measurement, mobility, convenience in the field information monitoring process. The whole structure of system is given and the key designs of system design are described in the hardware and software aspect. The studies have expanded current field information measurement methods and strengthen the application of the Internet of Things.

  20. Remote monitoring of lower-limb prosthetic socket fit using wireless technologies.

    PubMed

    Sahandi, R; Sewell, P; Noroozi, S; Hewitt, M

    2012-01-01

    Accurate fitting of a lower-limb prosthetic socket is the most important factor affecting amputee satisfaction and rehabilitation. The technology is now available to allow real-time monitoring of in-service pressure distribution of prosthetic limbs. This paper proposes a remote interfacial pressure monitoring system necessary for the assessment of fit. The suitability of a wireless ZigBee network due to its relevant technical specification is investigated. The system enables remote monitoring of a prosthetic socket and its fit under different operating conditions thereby improving design, efficiency and effectiveness. The data can be used by prosthetists and may also be recorded for future training or for patient progress monitoring. This can minimize the number of iterations by getting it right first time, thereby minimizing the number of replacement prostheses. Copyright © 2012 Informa UK, Ltd.

  1. Hydrologic monitoring of a waste-injection well near Milton, Florida, June 1975 - December 1976

    USGS Publications Warehouse

    Pascale, Charles A.; Martin, J.B.

    1977-01-01

    Hydraulic and chemical data were collected through a monitoring program conducted by the U.S. Geological Survey at an industrial liquid-waste injection site 6 mi southwest of Milton, Fla., in Santa Rosa County. The injection system is described. Data include injection rates, volumes, and pressures; water-level data at three monitor wells and a standby injection well, and field and laboratory analyses of water samples from four wells. Hydraulic and geochemical effects of the waste-injection system at the plant as of December 31, 1976, have been detected only in the injection zone, the lower limestone of the Floridan aquifer. Increased pressures are evident at the three wells used to monitor the injection zone. Geochemical changes have been noted only at the deep-test monitor well closest to the injection well. (Woodard-USGS)

  2. Online Bridge Crack Monitoring with Smart Film

    PubMed Central

    Wang, Shuliang; Li, Xingxing; Zhou, Zhixiang; Zhang, Xu; Yang, Guang; Qiu, Minfeng

    2013-01-01

    Smart film crack monitoring method, which can be used for detecting initiation, length, width, shape, location, and propagation of cracks on real bridges, is proposed. Firstly, the fabrication of the smart film is developed. Then the feasibility of the method is analyzed and verified by the mechanical sensing character of the smart film under the two conditions of normal strain and crack initiation. Meanwhile, the coupling interference between parallel enameled wires of the smart film is discussed, and then low-frequency detecting signal and the custom communication protocol are used to decrease interference. On this basis, crack monitoring system with smart film is designed, where the collected crack data is sent to the remote monitoring center and the cracks are simulated and recurred. Finally, the monitoring system is applied to six bridges, and the effects are discussed. PMID:24489496

  3. Testing and Evaluating the Effectiveness of Advanced Technologies for Work Zones in Nevada

    DOT National Transportation Integrated Search

    2008-08-30

    The objective of this study was to evaluate two advanced technologies for improving safety in work zones: 1) speed monitoring display and 2) automatic work zone information system. In the evaluation of the speed monitoring display (also called a spee...

  4. Test-bed for the remote health monitoring system for bridge structures using FBG sensors

    NASA Astrophysics Data System (ADS)

    Lee, Chin-Hyung; Park, Ki-Tae; Joo, Bong-Chul; Hwang, Yoon-Koog

    2009-05-01

    This paper reports on test-bed for the long-term health monitoring system for bridge structures employing fiber Bragg grating (FBG) sensors, which is remotely accessible via the web, to provide real-time quantitative information on a bridge's response to live loading and environmental changes, and fast prediction of the structure's integrity. The sensors are attached on several locations of the structure and connected to a data acquisition system permanently installed onsite. The system can be accessed through remote communication using an optical cable network, through which the evaluation of the bridge behavior under live loading can be allowed at place far away from the field. Live structural data are transmitted continuously to the server computer at the central office. The server computer is connected securely to the internet, where data can be retrieved, processed and stored for the remote web-based health monitoring. Test-bed revealed that the remote health monitoring technology will enable practical, cost-effective, and reliable condition assessment and maintenance of bridge structures.

  5. Health Monitoring for Airframe Structural Characterization

    NASA Technical Reports Server (NTRS)

    Munns, Thomas E.; Kent, Renee M.; Bartolini, Antony; Gause, Charles B.; Borinski, Jason W.; Dietz, Jason; Elster, Jennifer L.; Boyd, Clark; Vicari, Larry; Ray, Asok; hide

    2002-01-01

    This study established requirements for structural health monitoring systems, identified and characterized a prototype structural sensor system, developed sensor interpretation algorithms, and demonstrated the sensor systems on operationally realistic test articles. Fiber-optic corrosion sensors (i.e., moisture and metal ion sensors) and low-cycle fatigue sensors (i.e., strain and acoustic emission sensors) were evaluated to validate their suitability for monitoring aging degradation; characterize the sensor performance in aircraft environments; and demonstrate placement processes and multiplexing schemes. In addition, a unique micromachined multimeasure and sensor concept was developed and demonstrated. The results show that structural degradation of aircraft materials could be effectively detected and characterized using available and emerging sensors. A key component of the structural health monitoring capability is the ability to interpret the information provided by sensor system in order to characterize the structural condition. Novel deterministic and stochastic fatigue damage development and growth models were developed for this program. These models enable real time characterization and assessment of structural fatigue damage.

  6. Development of a new Clinical Engineering Management Tool & Information System (CLE-MANTIS).

    PubMed

    Panousis, S G; Malataras, P; Patelodimou, C; Kolitsi, Z; Pallikarakis, N

    1997-01-01

    The evolution of the field of biomedical technology has led to the diffusion of an impressive number of medical devices into healthcare institutions. In this environment, Clinical Engineering Departments (CEDs) are expanding their role in healthcare technology management, by changing their structure and introducing quality systems in order to improve their services and monitor the outcomes. In the framework of the national project BIOTECHNET II, a software tool for the management of biomedical technology, named CLE-MANTIS, has been developed, with the aim to assist CEDs in their tasks. CLE-MANTIS functions include the upkeep of an inventory, the support and monitoring of scheduled maintenance, corrective maintenance, vigilance, equipment acquisition and replacement, service contract management and user training. The system offers clinical engineers the possibility to monitor and evaluate the quality and cost-effectiveness of their departments through the monitoring of quality and cost indicators. This paper presents the main features and functions of the system.

  7. Development of a brain monitoring system for multimodality investigation in awake rats.

    PubMed

    Limnuson, Kanokwan; Narayan, Raj K; Chiluwal, Amrit; Bouton, Chad; Ping Wang; Chunyan Li

    2016-08-01

    Multimodal brain monitoring is an important approach to gain insight into brain function, modulation, and pathology. We have developed a unique micromachined neural probe capable of real-time continuous monitoring of multiple physiological, biochemical and electrophysiological variables. However, to date, it has only been used in anesthetized animals due to a lack of an appropriate interface for awake animals. We have developed a versatile headstage for recording the small neural signal and bridging the sensors to the remote sensing units for multimodal brain monitoring in awake rats. The developed system has been successfully validated in awake rats by simultaneously measuring four cerebral variables: electrocorticography, oxygen tension, temperature and cerebral blood flow. Reliable signal recordings were obtained with minimal artifacts from movement and environmental noise. For the first time, multiple variables of cerebral function and metabolism were simultaneously recorded from awake rats using a single neural probe. The system is envisioned for studying the effects of pharmacologic treatments, mapping the development of central nervous system diseases, and better understanding normal cerebral physiology.

  8. Participation in a national nursing outcomes database: monitoring outcomes over time.

    PubMed

    Loan, Lori A; Patrician, Patricia A; McCarthy, Mary

    2011-01-01

    The current and future climates in health care require increased accountability of health care organizations for the quality of the care they provide. Never before in the history of health care in America has this focus on quality been so critical. The imperative to measure nursing's impact without fully developed and tested monitoring systems is a critical issue for nurse executives and managers alike. This article describes a project to measure nursing structure, process, and outcomes in the military health system, the Military Nursing Outcomes Database project. Here we review the effectiveness of this project in monitoring changes over time, in satisfying expectations of nurse leaders in participating hospitals, and evaluate the potential budgetary impacts of such a system. We conclude that the Military Nursing Outcomes Database did meet the needs of a monitoring system that is sensitive to changes over time in outcomes, provides interpretable data for nurse leaders, and could result in cost benefits and patient care improvements in organizations.

  9. Monitoring system and methods for a distributed and recoverable digital control system

    NASA Technical Reports Server (NTRS)

    Stange, Kent (Inventor); Hess, Richard (Inventor); Kelley, Gerald B (Inventor); Rogers, Randy (Inventor)

    2010-01-01

    A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

  10. WLCG Monitoring Consolidation and further evolution

    NASA Astrophysics Data System (ADS)

    Saiz, P.; Aimar, A.; Andreeva, J.; Babik, M.; Cons, L.; Dzhunov, I.; Forti, A.; di Girolamo, A.; Karavakis, E.; Litmaath, M.; Magini, N.; Magnoni, L.; de los Rios, H. Martin; Roiser, S.; Sciaba, A.; Schulz, M.; Tarragon, J.; Tuckett, D.

    2015-12-01

    The WLCG monitoring system solves a challenging task of keeping track of the LHC computing activities on the WLCG infrastructure, ensuring health and performance of the distributed services at more than 170 sites. The challenge consists of decreasing the effort needed to operate the monitoring service and to satisfy the constantly growing requirements for its scalability and performance. This contribution describes the recent consolidation work aimed to reduce the complexity of the system, and to ensure more effective operations, support and service management. This was done by unifying where possible the implementation of the monitoring components. The contribution also covers further steps like the evaluation of the new technologies for data storage, processing and visualization and migration to a new technology stack.

  11. Fatigue of Ti6Al4V Structural Health Monitoring Systems Produced by Selective Laser Melting.

    PubMed

    Strantza, Maria; Vafadari, Reza; de Baere, Dieter; Vrancken, Bey; van Paepegem, Wim; Vandendael, Isabelle; Terryn, Herman; Guillaume, Patrick; van Hemelrijck, Danny

    2016-02-11

    Selective laser melting (SLM) is an additive manufacturing (AM) process which is used for producing metallic components. Currently, the integrity of components produced by SLM is in need of improvement due to residual stresses and unknown fracture behavior. Titanium alloys produced by AM are capable candidates for applications in aerospace and industrial fields due to their fracture resistance, fatigue behavior and corrosion resistance. On the other hand, structural health monitoring (SHM) system technologies are promising and requested from the industry. SHM systems can monitor the integrity of a structure and during the last decades the research has primarily been influenced by bionic engineering. In that aspect a new philosophy for SHM has been developed: the so-called effective structural health monitoring (eSHM) system. The current system uses the design freedom provided by AM. The working principle of the system is based on crack detection by means of a network of capillaries that are integrated in a structure. The main objective of this research is to evaluate the functionality of Ti6Al4V produced by the SLM process in the novel SHM system and to confirm that the eSHM system can successfully detect cracks in SLM components. In this study four-point bending fatigue tests on Ti6Al4V SLM specimens with an integrated SHM system were conducted. Fractographic analysis was performed after the final failure, while finite element simulations were used in order to determine the stress distribution in the capillary region and on the component. It was proven that the SHM system does not influence the crack initiation behavior during fatigue. The results highlight the effectiveness of the eSHM on SLM components, which can potentially be used by industrial and aerospace applications.

  12. System study of the carbon dioxide observational platform system (CO-OPS): Project overview

    NASA Technical Reports Server (NTRS)

    Stephens, J. Briscoe; Thompson, Wilbur E.

    1987-01-01

    The resulting options from a system study for a near-space, geo-stationary, observational monitoring platform system for use in the Department of Energy's (DOE) National Carbon Dioxide Observational Platform System (CO-OPS) on the greenhouse effect are discussed. CO-OPS is being designed to operate continuously for periods of up to 3 months in quasi-fixed position over most global regional targets of interest and could make horizon observations over a land-sea area of circular diameter up to about 600 to 800 statute miles. This affords the scientific and engineering community a low-cost means of operating their payloads for monitoring the regional parameters they deem relevant to their investigations of the carbon dioxide greenhouse effect at one-tenth the cost of most currently utilized comparable remote sensing techniques.

  13. Monitoring the performance of a storm water separating manifold with distributed temperature sensing.

    PubMed

    Langeveld, J G; de Haan, C; Klootwijk, M; Schilperoort, R P S

    2012-01-01

    Storm water separating manifolds in house connections have been introduced as a cost effective solution to disconnect impervious areas from combined sewers. Such manifolds have been applied by the municipality of Breda, the Netherlands. In order to investigate the performance of the manifolds, a monitoring technique (distributed temperature sensing or DTS) using fiber optic cables has been applied in the sewer system of Breda. This paper describes the application of DTS as a research tool in sewer systems. DTS proves to be a powerful tool to monitor the performance of (parts of) a sewer system in time and space. The research project showed that DTS is capable of monitoring the performance of house connections and identifying locations of inflow of both sewage and storm runoff. The research results show that the performance of storm water separating manifolds varies over time, thus making them unreliable.

  14. [Personal computer-based computer monitoring system of the anesthesiologist (2-year experience in development and use)].

    PubMed

    Buniatian, A A; Sablin, I N; Flerov, E V; Mierbekov, E M; Broĭtman, O G; Shevchenko, V V; Shitikov, I I

    1995-01-01

    Creation of computer monitoring systems (CMS) for operating rooms is one of the most important spheres of personal computer employment in anesthesiology. The authors developed a PC RS/AT-based CMS and effectively used it for more than 2 years. This system permits comprehensive monitoring in cardiosurgical operations by real time processing the values of arterial and central venous pressure, pressure in the pulmonary artery, bioelectrical activity of the brain, and two temperature values. Use of this CMS helped appreciably improve patients' safety during surgery. The possibility to assess brain function by computer monitoring the EEF simultaneously with central hemodynamics and body temperature permit the anesthesiologist to objectively assess the depth of anesthesia and to diagnose cerebral hypoxia. Automated anesthesiological chart issued by the CMS after surgery reliably reflects the patient's status and the measures taken by the anesthesiologist.

  15. Validation of Procedures for Monitoring Crewmember Immune Function SDBI-1900, SMO-015 - Integrated Immune

    NASA Technical Reports Server (NTRS)

    Crucian, Brian; Stowe, Raymond; Mehta, Satish; Uchakin, Peter; Nehlsen-Cannarella, Sandra; Morukov, Boris; Pierson, Duane; Sams, Clarence

    2007-01-01

    There is ample evidence to suggest that space flight leads to immune system dysregulation. This may be a result of microgravity, confinement, physiological stress, radiation, environment or other mission-associated factors. The clinical risk from prolonged immune dysregulation during space flight are not yet determined, but may include increased incidence of infection, allergy, hypersensitivity, hematological malignancy or altered wound healing. Each of the clinical events resulting from immune dysfunction has the potential to impact mission critical objectives during exploration-class missions. To date, precious little in-flight immune data has been generated to assess this phenomenon. The majority of recent flight immune studies have been post-flight assessments, which may not accurately reflect the in-flight condition. There are no procedures currently in place to monitor immune function or its effect on crew health. The objective of this Supplemental Medical Objective (SMO) is to develop and validate an immune monitoring strategy consistent with operational flight requirements and constraints. This SMO will assess the clinical risks resulting from the adverse effects of space flight on the human immune system and will validate a flight-compatible immune monitoring strategy. Characterization of the clinical risk and the development of a monitoring strategy are necessary prerequisite activities prior to validating countermeasures. This study will determine, to the best level allowed by current technology, the in-flight status of crewmembers immune system. Pre-flight, in-flight and post-flight assessments of immune status, immune function, viral reactivation and physiological stress will be performed. The in-flight samples will allow a distinction between legitimate in-flight alterations and the physiological stresses of landing and readaptation which are believed to alter landing day assessments. The overall status of the immune system during flight (activation, deficiency, dysregulation) and the response of the immune system to specific latent virus reactivation (known to occur during space flight) will be thoroughly assessed. Following completion of the SMO the data will be evaluated to determine the optimal set of assays for routine monitoring of crewmember immune system function, should the clinical risk warrant such monitoring.

  16. DEVELOPMENT, INSTALLATION AND OPERATION OF THE MPC&A OPERATIONS MONITORING (MOM) SYSTEM AT THE JOINT INSTITUTE FOR NUCLEAR RESEARCH (JINR) DUBNA, RUSSIA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kartashov,V.V.; Pratt,W.; Romanov, Y.A.

    The Material Protection, Control and Accounting (MPC&A) Operations Monitoring (MOM) systems handling at the International Intergovernmental Organization - Joint Institute for Nuclear Research (JINR) is described in this paper. Category I nuclear material (plutonium and uranium) is used in JINR research reactors, facilities and for scientific and research activities. A monitoring system (MOM) was installed at JINR in April 2003. The system design was based on a vulnerability analysis, which took into account the specifics of the Institute. The design and installation of the MOM system was a collaborative effort between JINR, Brookhaven National Laboratory (BNL) and the U.S. Departmentmore » of Energy (DOE). Financial support was provided by DOE through BNL. The installed MOM system provides facility management with additional assurance that operations involving nuclear material (NM) are correctly followed by the facility personnel. The MOM system also provides additional confidence that the MPC&A systems continue to perform effectively.« less

  17. Monitoring that matters

    USGS Publications Warehouse

    Johnson, Douglas H.; Gitzen, Robert A.; Millspaugh, Joshua J.; Cooper, Andrew B.; Licht, Daniel S.

    2012-01-01

    Monitoring is a critically important activity for assessing the status of a system, such as the health of an individual, the balance in one's checking account, profits and losses of a business, the economic activity of a nation, or the size of an animal population. Monitoring is especially vital for evaluating changes in the system associated with specific known impacts occurring to the system. It is also valuable for detecting unanticipated changes in the system and identifying plausible causes of such changes, all in time to take corrective action. Before proceeding, we should define "monitoring." One definition of "monitor" (Microsoft Corporation 2009) is "to check something at regular intervals in order to find out how it is progressing or developing." The key point here is "at regular intervals," suggesting a continuing process. Some definitions do not indicate the repetitive nature of monitoring and are basically synonymous with "observing." Most monitoring, in the strict sense of the word, is intended to persist for long periods of time, perhaps indefinitely or permanently. Similarly, Thompson et al. (1998: 3) referred to the "repeated assessment of status" of something, but noted that the term "monitor" is sometimes used for analogous activities such as collecting baseline information or evaluating projects for either implementation or effectiveness. For their purposes, they restricted the term to involve repeated measurements collected at a specified frequency of time units. Let us adopt that definition, recognizing that repeated measurements imply collecting comparable information on each occasion.

  18. Characteristics Study of In-Situ Capacitive Sensor for Monitoring Lubrication Oil Debris.

    PubMed

    Han, Zhibin; Wang, Yishou; Qing, Xinlin

    2017-12-08

    As an essential part of engine health monitoring (EHM), online lubrication oil debris monitoring has recently received great attention for the assessment of rotating and reciprocating parts in aero-engines, due to its high integration, low cost and safe characteristics. However, it is be a challenge to find a suitable sensor operating in such a complex environment. We present an unconventional novel approach, in which a cylinder capacitive sensor is designed and integrated with the pipeline of an engine lubrication system, so that the capacitive sensor can effectively detect changes in the lubrication oil condition. In this paper, an attempt to illustrate the performance characteristics of the developed cylinder capacitive sensor is made, through an experiment system that simulates a real scenario of a lubrication oil system. The main aim of the research was to qualitatively describe the relationship between the sensor parameter and the lubrication oil debris. In addition, the effect of the temperature and flow rate of the lubrication oil on capacitance change was performed by several experiments and we figured out a compensation method. The experimental results demonstrated that the cylinder capacitive sensor can potentially be used for lubrication oil debris monitoring of the health condition of an aero-engine.

  19. Review of NJ point system.

    DOT National Transportation Integrated Search

    2013-03-01

    The purpose of this study is to investigate the comparative effectiveness of point-based versus incident-based : negligent driver monitoring systems and to explore how certain changes to the existing point-based system used in : New Jersey might impr...

  20. 23 CFR 500.110 - PTMS.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT MANAGEMENT AND MONITORING SYSTEMS Management Systems § 500.110 PTMS. An effective PTMS for public transportation facilities (e.g... transportation systems operated by the State, local jurisdictions, public transportation agencies and authorities...

  1. Long-term fish monitoring in large rivers: Utility of “benchmarking” across basins

    USGS Publications Warehouse

    Ward, David L.; Casper, Andrew F.; Counihan, Timothy D.; Bayer, Jennifer M.; Waite, Ian R.; Kosovich, John J.; Chapman, Colin; Irwin, Elise R.; Sauer, Jennifer S.; Ickes, Brian; McKerrow, Alexa

    2017-01-01

    In business, benchmarking is a widely used practice of comparing your own business processes to those of other comparable companies and incorporating identified best practices to improve performance. Biologists and resource managers designing and conducting monitoring programs for fish in large river systems tend to focus on single river basins or segments of large rivers, missing opportunities to learn from those conducting fish monitoring in other rivers. We briefly examine five long-term fish monitoring programs in large rivers in the United States (Colorado, Columbia, Mississippi, Illinois, and Tallapoosa rivers) and identify opportunities for learning across programs by detailing best monitoring practices and why these practices were chosen. Although monitoring objectives, methods, and program maturity differ between each river system, examples from these five case studies illustrate the important role that long-term monitoring programs play in interpreting temporal and spatial shifts in fish populations for both established objectives and newly emerging questions. We suggest that deliberate efforts to develop a broader collaborative network through benchmarking will facilitate sharing of ideas and development of more effective monitoring programs.

  2. Remote photoplethysmography system for unsupervised monitoring regional anesthesia effectiveness

    NASA Astrophysics Data System (ADS)

    Rubins, U.; Miscuks, A.; Marcinkevics, Z.; Lange, M.

    2017-12-01

    Determining the level of regional anesthesia (RA) is vitally important to both an anesthesiologist and surgeon, also knowing the RA level can protect the patient and reduce the time of surgery. Normally to detect the level of RA, usually a simple subjective (sensitivity test) and complicated quantitative methods (thermography, neuromyography, etc.) are used, but there is not yet a standardized method for objective RA detection and evaluation. In this study, the advanced remote photoplethysmography imaging (rPPG) system for unsupervised monitoring of human palm RA is demonstrated. The rPPG system comprises compact video camera with green optical filter, surgical lamp as a light source and a computer with custom-developed software. The algorithm implemented in Matlab software recognizes the palm and two dermatomes (Medial and Ulnar innervation), calculates the perfusion map and perfusion changes in real-time to detect effect of RA. Seven patients (aged 18-80 years) undergoing hand surgery received peripheral nerve brachial plexus blocks during the measurements. Clinical experiments showed that our rPPG system is able to perform unsupervised monitoring of RA.

  3. Reliability in individual monitoring service.

    PubMed

    Mod Ali, N

    2011-03-01

    As a laboratory certified to ISO 9001:2008 and accredited to ISO/IEC 17025, the Secondary Standard Dosimetry Laboratory (SSDL)-Nuclear Malaysia has incorporated an overall comprehensive system for technical and quality management in promoting a reliable individual monitoring service (IMS). Faster identification and resolution of issues regarding dosemeter preparation and issuing of reports, personnel enhancement, improved customer satisfaction and overall efficiency of laboratory activities are all results of the implementation of an effective quality system. Review of these measures and responses to observed trends provide continuous improvement of the system. By having these mechanisms, reliability of the IMS can be assured in the promotion of safe behaviour at all levels of the workforce utilising ionising radiation facilities. Upgradation of in the reporting program through a web-based e-SSDL marks a major improvement in Nuclear Malaysia's IMS reliability on the whole. The system is a vital step in providing a user friendly and effective occupational exposure evaluation program in the country. It provides a higher level of confidence in the results generated for occupational dose monitoring of the IMS, thus, enhances the status of the radiation protection framework of the country.

  4. URBAN-NET: A Network-based Infrastructure Monitoring and Analysis System for Emergency Management and Public Safety

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Sangkeun; Chen, Liangzhe; Duan, Sisi

    Abstract Critical Infrastructures (CIs) such as energy, water, and transportation are complex networks that are crucial for sustaining day-to-day commodity flows vital to national security, economic stability, and public safety. The nature of these CIs is such that failures caused by an extreme weather event or a man-made incident can trigger widespread cascading failures, sending ripple effects at regional or even national scales. To minimize such effects, it is critical for emergency responders to identify existing or potential vulnerabilities within CIs during such stressor events in a systematic and quantifiable manner and take appropriate mitigating actions. We present here amore » novel critical infrastructure monitoring and analysis system named URBAN-NET. The system includes a software stack and tools for monitoring CIs, pre-processing data, interconnecting multiple CI datasets as a heterogeneous network, identifying vulnerabilities through graph-based topological analysis, and predicting consequences based on what-if simulations along with visualization. As a proof-of-concept, we present several case studies to show the capabilities of our system. We also discuss remaining challenges and future work.« less

  5. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mayer, J.

    The U. S. Department of Energy's (DOE) Office of Environmental Management (EM) has the responsibility for cleaning up 60 sites in 22 states that were associated with the legacy of the nation's nuclear weapons program and other research and development activities. These sites are unique and many of the technologies needed to successfully disposition the associated wastes have yet to be developed or would require significant re-engineering to be adapted for future EM cleanup efforts. In 2008, the DOE-EM Engineering and Technology Program (EM-22) released the Engineering and Technology Roadmap in response to Congressional direction and the need to focusmore » on longer term activities required for the completion of the aforementioned cleanup program. One of the strategic initiatives included in the Roadmap was to enhance long term performance monitoring as defined by 'Develop and deploy cost effective long-term strategies and technologies to monitor closure sites (including soil, groundwater, and surface water) with multiple contaminants (organics, metals and radionuclides) to verify integrated long-term cleanup performance'. To support this long-term monitoring (LTM) strategic initiative, EM 22 and the Savannah River National Laboratory (SRNL) organized and held an interactive symposia, known as the 2009 DOE-EM Long-Term Monitoring Technical Forum, to define and prioritize LTM improvement strategies and products that could be realized within a 3 to 5 year investment time frame. This near-term focus on fundamental research would then be used as a foundation for development of applied programs to improve the closure and long-term performance of EM's legacy waste sites. The Technical Forum was held in Atlanta, GA on February 11-12, 2009, and attended by 57 professionals with a focus on identifying those areas of opportunity that would most effectively advance the transition of the current practices to a more effective strategy for the LTM paradigm. The meeting format encompassed three break-out sessions, which focused on needs and opportunities associated with the following LTM technical areas: (1) Performance Monitoring Tools, (2) Systems, and (3) Information Management. The specific objectives of the Technical Forum were to identify: (1) technical targets for reducing EM costs for life-cycle monitoring; (2) cost-effective approaches and tools to support the transition from active to passive remedies at EM waste sites; and (3) specific goals and objectives associated with the lifecycle monitoring initiatives outlined within the Roadmap. The first Breakout Session on LTM performance measurement tools focused on the integration and improvement of LTM performance measurement and monitoring tools that deal with parameters such as ecosystems, boundary conditions, geophysics, remote sensing, biomarkers, ecological indicators and other types of data used in LTM configurations. Although specific tools were discussed, it was recognized that the Breakout Session could not comprehensively discuss all monitoring technologies in the time provided. Attendees provided key references where other organizations have assessed monitoring tools. Three investment sectors were developed in this Breakout Session. The second Breakout Session was on LTM systems. The focus of this session was to identify new and inventive LTM systems addressing the framework for interactive parameters such as infrastructure, sensors, diagnostic features, field screening tools, state of the art characterization monitoring systems/concepts, and ecosystem approaches to site conditions and evolution. LTM systems consist of the combination of data acquisition and management efforts, data processing and analysis efforts and reporting tools. The objective of the LTM systems workgroup was to provide a vision and path towards novel and innovative LTM systems, which should be able to provide relevant, actionable information on system performance in a cost-effective manner. Two investment sectors were developed in this Breakout Session. The last Breakout Session of the Technical Forum was on LTM information management. The session focus was on the development and implementation of novel information management systems for LTM including techniques to address data issues such as: efficient management of large and diverse datasets; consistency and comparability in data management and incorporation of accurate historical information; data interpretation and information synthesis including statistical methods, modeling, and visualization; and linage of data to site management objectives and leveraging information to forge consensus among stakeholders. One investment sector was developed in this Breakout Session.« less

  6. Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring.

    PubMed

    Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin

    2017-09-26

    Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.

  7. Detection of system failures in multi-axes tasks. [pilot monitored instrument approach

    NASA Technical Reports Server (NTRS)

    Ephrath, A. R.

    1975-01-01

    The effects of the pilot's participation mode in the control task on his workload level and failure detection performance were examined considering a low visibility landing approach. It is found that the participation mode had a strong effect on the pilot's workload, the induced workload being lowest when the pilot acted as a monitoring element during a coupled approach and highest when the pilot was an active element in the control loop. The effects of workload and participation mode on failure detection were separated. The participation mode was shown to have a dominant effect on the failure detection performance, with a failure in a monitored (coupled) axis being detected significantly faster than a comparable failure in a manually controlled axis.

  8. Remote glucose monitoring in cAMP setting reduces the risk of prolonged nocturnal hypoglycemia.

    PubMed

    DeSalvo, Daniel J; Keith-Hynes, Patrick; Peyser, Thomas; Place, Jérôme; Caswell, Kim; Wilson, Darrell M; Harris, Breanne; Clinton, Paula; Kovatchev, Boris; Buckingham, Bruce A

    2014-01-01

    This study tested the feasibility and effectiveness of remote continuous glucose monitoring (CGM) in a diabetes camp setting. Twenty campers (7-21 years old) with type 1 diabetes were enrolled at each of three camp sessions lasting 5-6 days. On alternating nights, 10 campers were randomized to usual wear of a Dexcom (San Diego, CA) G4™ PLATINUM CGM system, and 10 were randomized to remote monitoring with the Dexcom G4 PLATINUM communicating with the Diabetes Assistant, a cell phone platform, to allow wireless transmission of CGM values. Up to 15 individual graphs and sensor values could be displayed on a single remote monitor or portable tablet. An alarm was triggered for values <70 mg/dL, and treatment was given for meter-confirmed hypoglycemia. The primary end point was to decrease the duration of hypoglycemic episodes <50 mg/dL. There were 320 nights of CGM data and 197 hypoglycemic events. Of the remote monitoring alarms, 79% were true (meter reading of <70 mg/dL). With remote monitoring, 100% of alarms were responded to, whereas without remote monitoring only 54% of alarms were responded to. The median duration of hypoglycemic events <70 mg/dL was 35 min without remote monitoring and 30 min with remote monitoring (P=0.078). Remote monitoring significantly decreased prolonged hypoglycemic events, eliminating all events <50 mg/dL lasting longer than 30 min as well as all events <70 mg/dL lasting more than 2 h. Remote monitoring is feasible at diabetes camps and effective in reducing the risk of prolonged nocturnal hypoglycemia. This technology will facilitate forthcoming studies to evaluate the efficacy of automated closed-loop systems in the camp setting.

  9. Utility gas turbine combustor viewing system: Volume 2, Engine operating envelope test: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morey, W.W.

    1988-12-01

    This report summarizes the development and field testing of a combustor viewing probe (CVP) as a flame diagnostic monitor for utility gas turbine engines. The prototype system is capable of providing a visual record of combustor flame images, recording flame spectral data, analyzing image and spectral data, and diagnosing certain engine malfunctions. The system should provide useful diagnostic information to utility plant operators, and reduced maintenance costs. The field tests demonstrated the ability of the CVP to monitor combustor flame condition and to relate changes in the engine operation with variations in the flame signature. Engine light off, run upmore » to full speed, the addition of load, and the effect of water injection for NO/sub x/ control could easily be identified on the video monitor. The viewing probe was also valuable in identifying hard startups and shutdowns, as well as transient effects that can seriously harm the engine.« less

  10. Utility gas turbine combustor viewing system: Volume 1, Conceptual design and initial field testing: Final report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morey, W.W.

    1988-12-01

    This report summarizes the development and field testing of a combustor viewing probe (CVP) as a flame diagnostic monitor for utility gas turbine engines. The prototype system is capable of providing a visual record of combustor flame images, recording flame spectral data, analyzing image and spectral data, and diagnosing certain engine malfunctions. The system should provide useful diagnostic information to utility plant operators, and reduce maintenance costs. The field tests demonstrated the ability of the CVP to monitor combustor flame condition and to relate changes in the engine operation with variations in the flame signature. Engine light off, run upmore » to full speed, the addition of load, and the effect of water injection for NO/sub x/ control could easily be identified on the video monitor. The viewing probe was also valuable in identifying hard startups and shutdowns, as well as transient effects that can seriously harm the engine. 11 refs.« less

  11. Symbolic Constraint Maintenance Grid

    NASA Technical Reports Server (NTRS)

    James, Mark

    2006-01-01

    Version 3.1 of Symbolic Constraint Maintenance Grid (SCMG) is a software system that provides a general conceptual framework for utilizing pre-existing programming techniques to perform symbolic transformations of data. SCMG also provides a language (and an associated communication method and protocol) for representing constraints on the original non-symbolic data. SCMG provides a facility for exchanging information between numeric and symbolic components without knowing the details of the components themselves. In essence, it integrates symbolic software tools (for diagnosis, prognosis, and planning) with non-artificial-intelligence software. SCMG executes a process of symbolic summarization and monitoring of continuous time series data that are being abstractly represented as symbolic templates of information exchange. This summarization process enables such symbolic- reasoning computing systems as artificial- intelligence planning systems to evaluate the significance and effects of channels of data more efficiently than would otherwise be possible. As a result of the increased efficiency in representation, reasoning software can monitor more channels and is thus able to perform monitoring and control functions more effectively.

  12. Method for monitoring environmental and corrosion

    DOEpatents

    Glass, R.S.; Clarke, W.L. Jr.; Ciarlo, D.R.

    1995-08-01

    A corrosion sensor array is described incorporating individual elements for measuring various elements and ions, such as chloride, sulfide, copper, hydrogen (pH), etc. and elements for evaluating the instantaneous corrosion properties of structural materials. The exact combination and number of elements measured or monitored would depend upon the environmental conditions and materials used which are subject to corrosive effects. Such a corrosion monitoring system embedded in or mounted on a structure exposed to the environment would serve as an early warning system for the onset of severe corrosion problems for the structure, thus providing a safety factor as well as economic factors. The sensor array is accessed to an electronics/computational system, which provides a means for data collection and analysis. 7 figs.

  13. A portable detection system for in vivo monitoring of 131I in routine and emergency situations

    NASA Astrophysics Data System (ADS)

    Lucena, EA; Dantas, ALA; Dantas, BM

    2018-03-01

    In vivo monitoring of 131I in human thyroid is often used to evaluate occupational exposure in nuclear medicine facilities and in the case of accidental intakes in nuclear power plants for the monitoring of workers and population. The device presented in this work consists on a Pb-collimated NaI(Tl)3”x3” scintillation detector assembled on a tripod and connected to a portable PC. The evaluation of the applicability and limitations of the system is based on the estimation of the committed effective doses associated to the minimum detectable activities in different facilities. It has been demonstrated that the system is suitable for use in routine and accidental situations.

  14. Designing and Evaluating Participatory Cyber-Infrastructure Systems for Multi-Scale Citizen Science

    ERIC Educational Resources Information Center

    Newman, Gregory J.

    2010-01-01

    Widespread and continuous spatial and temporal environmental data is essential for effective environmental monitoring, sustainable natural resource management, and ecologically responsible decisions. Our environmental monitoring, data management and reporting enterprise is not matched to current problems, concerns, and decision-making needs.…

  15. Drought monitoring: Historical and current perspectives

    USDA-ARS?s Scientific Manuscript database

    Given the complex dimensions of drought and the challenges they pose for routine drought monitoring, it is essential that we continue to find innovative and robust ways to quantify and more effectively communicate the impacts of this hazard as part of an operational Drought Early Warning System. Th...

  16. Monitoring Natural World Heritage Sites: optimization of the monitoring system in Bogda with GIS-based multi-criteria decision analysis.

    PubMed

    Wang, Zhaoguo; Du, Xishihui

    2016-07-01

    Natural World Heritage Sites (NWHSs) are invaluable treasure due to the uniqueness of each site. Proper monitoring and management can guarantee their protection from multiple threats. In this study, geographic information system (GIS)-based multi-criteria decision analysis (GIS-MCDA) was used to assess criteria layers acquired from the data available in the literature. A conceptual model for determining the priority area for monitoring in Bogda, China, was created based on outstanding universal values (OUV) and expert knowledge. Weights were assigned to each layer using the analytic hierarchy process (AHP) based on group decisions, encompassing three experts: one being a heritage site expert, another a forest ranger, and the other a heritage site manager. Subsequently, evaluation layers and constraint layers were used to generate a priority map and to determine the feasibility of monitoring in Bogda. Finally, a monitoring suitability map of Bogda was obtained by referencing priority and feasibility maps.The high-priority monitoring area is located in the montane forest belt, which exhibits high biodiversity and is the main tourist area of Bogda. The northern buffer zone of Bogda comprises the concentrated feasible monitoring areas, and the area closest to roads and monitoring facilities is highly feasible for NWHS monitoring. The suitability of an area in terms of monitoring is largely determined by the monitoring priority in that particular area. The majority of planned monitoring facilities are well distributed in both suitable and less suitable areas. Analysis results indicate that the protection of Bogda will be more scientifically based due to its effective and all-around planned monitoring system proposed by the declaration text of Xinjiang Tianshan, which is the essential file submitted to World Heritage Centre to inscribe as a NWHS.

  17. CHRONIOUS: a wearable platform for monitoring and management of patients with chronic disease.

    PubMed

    Bellos, Christos; Papadopoulos, Athanassios; Rosso, Roberto; Fotiadis, Dimitrios I

    2011-01-01

    The CHRONIOUS system has been developed based on an open architecture design that consists of a set of subsystems which interact in order to provide all the needed services to the chronic disease patients. An advanced multi-parametric expert system is being implemented that fuses information effectively from various sources using intelligent techniques. Data are collected by sensors of a body network controlling vital signals while additional tools record dietary habits and plans, drug intake, environmental and biochemical parameters and activity data. The CHRONIOUS platform provides guidelines and standards for the future generations of "chronic disease management systems" and facilitates sophisticated monitoring tools. In addition, an ontological information retrieval system is being delivered satisfying the necessities for up-to-date clinical information of Chronic Obstructive pulmonary disease (COPD) and Chronic Kidney Disease (CKD). Moreover, support tools are being embedded in the system, such as the Mental Tools for the monitoring of patient mental health status. The integrated platform provides real-time patient monitoring and supervision, both indoors and outdoors and represents a generic platform for the management of various chronic diseases.

  18. Quaternion Based Thermal Condition Monitoring System

    NASA Astrophysics Data System (ADS)

    Wong, Wai Kit; Loo, Chu Kiong; Lim, Way Soong; Tan, Poi Ngee

    In this paper, we will propose a new and effective machine condition monitoring system using log-polar mapper, quaternion based thermal image correlator and max-product fuzzy neural network classifier. Two classification characteristics namely: peak to sidelobe ratio (PSR) and real to complex ratio of the discrete quaternion correlation output (p-value) are applied in the proposed machine condition monitoring system. Large PSR and p-value observe in a good match among correlation of the input thermal image with a particular reference image, while small PSR and p-value observe in a bad/not match among correlation of the input thermal image with a particular reference image. In simulation, we also discover that log-polar mapping actually help solving rotation and scaling invariant problems in quaternion based thermal image correlation. Beside that, log-polar mapping can have a two fold of data compression capability. Log-polar mapping can help smoother up the output correlation plane too, hence makes a better measurement way for PSR and p-values. Simulation results also show that the proposed system is an efficient machine condition monitoring system with accuracy more than 98%.

  19. Introduction to monitoring dynamic environmental phenomena of the world using satellite data collection systems, 1978

    USGS Publications Warehouse

    Carter, William Douglas; Paulson, Richard W.

    1979-01-01

    The rapid development of satellite technology, especially in the area of radio transmission and imaging systems, makes it possible to monitor dynamic surface phenomena of the Earth in considerable detail. The monitoring systems that have been developed are compatible with standard monitoring systems such as snow, stream, and rain gages; wind, temperature and humidity measuring instruments; tiltmeters and seismic event counters. Supported by appropriate power, radios and antennae, remote stations can be left unattended for at least 1 year and consistently relay local information via polar orbiting or geostationary satellites. These data, in conjunction with timely Landsat images, can provide a basis for more accurate estimates on snowfall, water runoff, reservoir level changes, flooding, drought effects, and vegetation trends and may be of help in forecasting volcanic eruptions. These types of information are critical for resource inventory and development, especially in developing countries where remote regions are commonly difficult to access. This paper introduces the reader to the systems available, describes their features and limitations, and provides suggestions on how to employ them. An extensive bibliography is provided for those who wish more information.

  20. The Global Drought Information System - A Decision Support Tool with Global Applications

    NASA Astrophysics Data System (ADS)

    Heim, R. R.; Brewer, M.

    2012-12-01

    Drought is a natural hazard which can cause famine in developing countries and severe economic hardship in developed countries. Given current concerns with the increasing frequency and magnitude of droughts in many regions of the world, especially in the light of expected climate change, drought monitoring and dissemination of early warning information in a timely fashion on a global scale is a critical concern as an important adaptation and mitigation strategy. While a number of nations, and a few continental-scale activities have developed drought information system activities, a global drought early warning system (GDEWS) remains elusive, despite the benefits highlighted by ministers to the Global Earth Observation System of System in 2008. In an effort to begin a process of drought monitoring with international collaboration, the National Integrated Drought Information System's (NIDIS) U.S. Drought Portal, a web-based information system created to address drought services and early warning in the United States, including drought monitoring, forecasting, impacts, mitigation, research, and education, volunteered to develop a prototype Global Drought Monitoring Portal (GDMP). Through integration of data and information at the global level, and with four continental-level partners, the GDMP has proven successful as a tool to monitor drought around the globe. At a recent meeting between NIDIS, the World Meteorological Organization, and the Global Earth Observation System of Systems, it was recommended that the GDMP form the basis for a Global Drought Information System (GDIS). Currently, GDIS activities are focused around incorporating additional drought monitoring information, especially from those areas without regional or continental-scale input, and incorporating drought-specific climate forecast information from the World Climate Research Programme. Additional GDIS pilot activities are underway with an emphasis on information and decision making, and how to effectively provide drought early warning. This talk will provide an update on the status of GDIS and its role in international drought monitoring.

  1. Embedded programmable blood pressure monitoring system

    NASA Astrophysics Data System (ADS)

    Hasan, Md. Mahmud-Ul; Islam, Md. Kafiul; Shawon, Mehedi Azad; Nowrin, Tasnuva Faruk

    2010-02-01

    A more efficient newer algorithm of detecting systolic and diastolic pressure of human body along with a complete package of an effective user-friendly embedded programmable blood pressure monitoring system has been proposed in this paper to reduce the overall workload of medical personals as well as to monitor patient's condition more conveniently and accurately. Available devices for measuring blood pressure have some problems and limitations in case of both analog and digital devices. The sphygmomanometer, being analog device, is still being used widely because of its reliability and accuracy over digital ones. But it requires a skilled person to measure the blood pressure and obviously not being automated as well as time consuming. Our proposed system being a microcontroller based embedded system has the advantages of the available digital blood pressure machines along with a much improved form and has higher accuracy at the same time. This system can also be interfaced with computer through serial port/USB to publish the measured blood pressure data on the LAN or internet. The device can be programmed to determine the patient's blood pressure after each certain interval of time in a graphical form. To sense the pressure of human body, a pressure to voltage transducer is used along with a cuff in our system. During the blood pressure measurement cycle, the output voltage of the transducer is taken by the built-in ADC of microcontroller after an amplifier stage. The recorded data are then processed and analyzed using the effective software routine to determine the blood pressure of the person under test. Our proposed system is thus expected to certainly enhance the existing blood pressure monitoring system by providing accuracy, time efficiency, user-friendliness and at last but not the least the 'better way of monitoring patient's blood pressure under critical care' all together at the same time.

  2. Remote sensing new model for monitoring the east Asian migratory locust infections based on its breeding circle

    NASA Astrophysics Data System (ADS)

    Han, Xiuzhen; Ma, Jianwen; Bao, Yuhai

    2006-12-01

    Currently the function of operational locust monitor system mainly focused on after-hazards monitoring and assessment, and to found the way effectively to perform early warning and prediction has more practical meaning. Through 2001, 2002 two years continuously field sample and statistics for locusts eggs hatching, nymph growth, adults 3 phases observation, sample statistics and calculation, spectral measurements as well as synchronically remote sensing data processing we raise the view point of Remote Sensing three stage monitor the locust hazards. Based on the point of view we designed remote sensing monitor in three stages: (1) during the egg hitching phase remote sensing can retrieve parameters of land surface temperature (LST) and soil moisture; (2) during nymph growth phase locust increases appetite greatly and remote sensing can calculate vegetation index, leaf area index, vegetation cover and analysis changes; (3) during adult phase the locust move and assembly towards ponds and water ditches as well as less than 75% vegetation cover areas and remote sensing combination with field data can monitor and predicts potential areas for adult locusts to assembly. In this way the priority of remote sensing technology is elaborated effectively and it also provides technique support for the locust monitor system. The idea and techniques used in the study can also be used as reference for other plant diseases and insect pests.

  3. A privacy-strengthened scheme for E-Healthcare monitoring system.

    PubMed

    Huang, Chanying; Lee, Hwaseong; Lee, Dong Hoon

    2012-10-01

    Recent Advances in Wireless Body Area Networks (WBANs) offer unprecedented opportunities and challenges to the development of pervasive electronic healthcare (E-Healthcare) monitoring system. In E-Healthcare system, the processed data are patients' sensitive health data that are directly related to individuals' privacy. For this reason, privacy concern is of great importance for E-Healthcare system. Current existing systems for E-Healthcare services, however, have not yet provided sufficient privacy protection for patients. In order to offer adequate security and privacy, in this paper, we propose a privacy-enhanced scheme for patients' physical condition monitoring, which achieves dual effects: (1) providing unlinkability of health records and individual identity, and (2) supporting anonymous authentication and authorized data access. We also conduct a simulation experiment to evaluate the performance of the proposed scheme. The experimental results demonstrate that the proposed scheme achieves better performance in terms of computational complexity, communication overheads and querying efficiency compared with previous results.

  4. Safety management for polluted confined space with IT system: a running case.

    PubMed

    Hwang, Jing-Jang; Wu, Chien-Hsing; Zhuang, Zheng-Yun; Hsu, Yi-Chang

    2015-01-01

    This study traced a deployed real IT system to enhance occupational safety for a polluted confined space. By incorporating wireless technology, it automatically monitors the status of workers on the site and upon detected anomalous events, managers are notified effectively. The system, with a redefined standard operations process, is running well at one of Formosa Petrochemical Corporation's refineries. Evidence shows that after deployment, the system does enhance the safety level by real-time monitoring the workers and by managing well and controlling the anomalies. Therefore, such technical architecture can be applied to similar scenarios for safety enhancement purposes.

  5. Framework and implementation of a continuous network-wide health monitoring system for roadways

    NASA Astrophysics Data System (ADS)

    Wang, Ming; Birken, Ralf; Shahini Shamsabadi, Salar

    2014-03-01

    According to the 2013 ASCE report card America's infrastructure scores only a D+. There are more than four million miles of roads (grade D) in the U.S. requiring a broad range of maintenance activities. The nation faces a monumental problem of infrastructure management in the scheduling and implementation of maintenance and repair operations, and in the prioritization of expenditures within budgetary constraints. The efficient and effective performance of these operations however is crucial to ensuring roadway safety, preventing catastrophic failures, and promoting economic growth. There is a critical need for technology that can cost-effectively monitor the condition of a network-wide road system and provide accurate, up-to-date information for maintenance activity prioritization. The Versatile Onboard Traffic Embedded Roaming Sensors (VOTERS) project provides a framework and the sensing capability to complement periodical localized inspections to continuous network-wide health monitoring. Research focused on the development of a cost-effective, lightweight package of multi-modal sensor systems compatible with this framework. An innovative software infrastructure is created that collects, processes, and evaluates these large time-lapse multi-modal data streams. A GIS-based control center manages multiple inspection vehicles and the data for further analysis, visualization, and decision making. VOTERS' technology can monitor road conditions at both the surface and sub-surface levels while the vehicle is navigating through daily traffic going about its normal business, thereby allowing for network-wide frequent assessment of roadways. This deterioration process monitoring at unprecedented time and spatial scales provides unique experimental data that can be used to improve life-cycle cost analysis models.

  6. Development of an intelligent hydroinformatic system for real-time monitoring and assessment of civil infrastructure

    NASA Astrophysics Data System (ADS)

    Cahill, Paul; Michalis, Panagiotis; Solman, Hrvoje; Kerin, Igor; Bekic, Damir; Pakrashi, Vikram; McKeogh, Eamon

    2017-04-01

    With the effects of climate change becoming more apparent, extreme weather events are now occurring with greater frequency throughout the world. Such extreme events have resulted in increased high intensity flood events which are having devastating consequences on hydro-structures, especially on bridge infrastructure. The remote and often inaccessible nature of such bridges makes inspections problematic, a major concern if safety assessments are required during and after extreme flood events. A solution to this is the introduction of smart, low cost sensing solutions at locations susceptible to hydro-hazards. Such solutions can provide real-time information on the health of the bridge and its environments, with such information aiding in the mitigation of the risks associated with extreme weather events. This study presents the development of an intelligent system for remote, real-time monitoring of hydro-hazards to bridge infrastructure. The solution consists of two types of remote monitoring stations which have the capacity to monitor environmental conditions and provide real-time information to a centralized, big data database solution, from which an intelligent decision support system will accommodate the results to control and manage bridge, river and catchment assets. The first device developed as part of the system is the Weather Information Logging Device (WILD), which monitors rainfall, temperature and air and soil moisture content. The ability of the WILD to monitor rainfall in real time enables flood early warning alerts and predictive river flow conditions, thereby enabling decision makers the ability to make timely and effective decisions about critical infrastructures in advance of extreme flood events. The WILD is complemented by a second monitoring device, the Bridge Information Recording Device (BIRD), which monitors water levels at a given location in real-time. The monitoring of water levels of a river allows for, among other applications, hydraulic modelling to assess the likely impact that severe flood events will have on a bridges foundation, particularly due to scour. The process of reading and validating data from the WILD and BIRD buffer servers is outlined, as is the transmission protocol used for the sending of recorded data to a centralized repository for further use and analysis. Finally, the development of a centralized repository for the collection of data from the WILD and BIRD devices is presented. Eventually the big data solution would be used to receive, store and send the monitored data to the hydrological models, whether existing or developed, and the results would be transmitted to the intelligent decision support system based on a web-based platform, for managing, planning and executing data, processes and procedures for bridge assets. The development of intelligent hydroinformatic system is an important tool for the protection of key infrastructure assets from the increasingly common effects of climate change. Acknowledgement The authors wish to acknowledge the financial support of the European Commission, through the Marie Curie Industry-Academia Partnership and Pathways Network BRIDGE SMS (Intelligent Bridge Assessment Maintenance and Management System) - FP7-People-2013-IAPP- 612517.

  7. Research on intelligent monitoring technology of machining process

    NASA Astrophysics Data System (ADS)

    Wang, Taiyong; Meng, Changhong; Zhao, Guoli

    1995-08-01

    Based upon research on sound and vibration characteristics of tool condition, we explore the multigrade monitoring system which takes single-chip microcomputers as the core hardware. By using the specially designed pickup true signal devices, we can more effectively do the intelligent multigrade monitoring and forecasting, and furthermore, we can build the tool condition models adaptively. This is the key problem in FMS, CIMS, and even the IMS.

  8. Assessment of Fluid Balance and the Approach to Fluid Therapy in the Perioperative Patient.

    PubMed

    Boller, Elise; Boller, Manuel

    2015-09-01

    Perioperative patients can be highly dynamic and have various metabolic, physiologic, and organ system derangements that necessitate smart monitoring strategies and careful fluid therapy. The interplay between changing patient status, therapeutic interventions, and patient response makes effective monitoring crucial to successful treatment. Monitoring the perioperative patient and an approach to fluid therapy are discussed in this text. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Evaluation of SHM system produced by additive manufacturing via acoustic emission and other NDT methods.

    PubMed

    Strantza, Maria; Aggelis, Dimitrios G; de Baere, Dieter; Guillaume, Patrick; van Hemelrijck, Danny

    2015-10-21

    During the last decades, structural health monitoring (SHM) systems are used in order to detect damage in structures. We have developed a novel structural health monitoring approach, the so-called "effective structural health monitoring" (eSHM) system. The current SHM system is incorporated into a metallic structure by means of additive manufacturing (AM) and has the possibility to advance life safety and reduce direct operative costs. It operates based on a network of capillaries that are integrated into an AM structure. The internal pressure of the capillaries is continuously monitored by a pressure sensor. When a crack nucleates and reaches the capillary, the internal pressure changes signifying the existence of the flaw. The main objective of this paper is to evaluate the crack detection capacity of the eSHM system and crack location accuracy by means of various non-destructive testing (NDT) techniques. During this study, detailed acoustic emission (AE) analysis was applied in AM materials for the first time in order to investigate if phenomena like the Kaiser effect and waveform parameters used in conventional metals can offer valuable insight into the damage accumulation of the AM structure as well. Liquid penetrant inspection, eddy current and radiography were also used in order to confirm the fatigue damage and indicate the damage location on un-notched four-point bending AM metallic specimens with an integrated eSHM system. It is shown that the eSHM system in combination with NDT can provide correct information on the damage condition of additive manufactured metals.

  10. Regional health workforce monitoring as governance innovation: a German model to coordinate sectoral demand, skill mix and mobility.

    PubMed

    Kuhlmann, E; Lauxen, O; Larsen, C

    2016-11-28

    As health workforce policy is gaining momentum, data sources and monitoring systems have significantly improved in the European Union and internationally. Yet data remain poorly connected to policy-making and implementation and often do not adequately support integrated approaches. This brings the importance of governance and the need for innovation into play. The present case study introduces a regional health workforce monitor in the German Federal State of Rhineland-Palatinate and seeks to explore the capacity of monitoring to innovate health workforce governance. The monitor applies an approach from the European Network on Regional Labour Market Monitoring to the health workforce. The novel aspect of this model is an integrated, procedural approach that promotes a 'learning system' of governance based on three interconnected pillars: mixed methods and bottom-up data collection, strong stakeholder involvement with complex communication tools and shared decision- and policy-making. Selected empirical examples illustrate the approach and the tools focusing on two aspects: the connection between sectoral, occupational and mobility data to analyse skill/qualification mixes and the supply-demand matches and the connection between monitoring and stakeholder-driven policy. Regional health workforce monitoring can promote effective governance in high-income countries like Germany with overall high density of health workers but maldistribution of staff and skills. The regional stakeholder networks are cost-effective and easily accessible and might therefore be appealing also to low- and middle-income countries.

  11. The effect of ambient ozone and humidity on the performance of nylon and Teflon filters used in ambient air monitoring filter-pack systems

    Treesearch

    PE Padgett

    2010-01-01

    Nylon and Teflon filter media are frequently used for monitoring ambient air pollutants. These media are subject to many environmental factors that may influence adsorption and retention of particulate and gaseous nitrogenous pollutants. This study evaluated the effects of ozone and humidity on the efficacy of nylon and Teflon filters used in the US dry deposition...

  12. Atropine’s Effects upon the Heart and Its Systemic Output,

    DTIC Science & Technology

    1986-01-01

    CLASSIFICATION AUTHORITY 3 DISTRIBUTION/AVAILABILITY OF REPORT 2b. DECLASSIFICATION /DOWNGRADING SCHEDULE Unlimited 4. PERFORMING ORGANIZATION REPORT...NUMBER(S) S. MONITORING ORGANIZATION REPORT NUMBER(S) WRAIR ET-86-1 6a. NAME OF PERFORMING ORGANIZATION 6b OFFICE SYMBOL 7a NAME OF MONITORING...review of atropine’s effects upon sweat production abatement and the related consequences to exercise performance in humans, horses and dogs appears

  13. Description of real-time Ada software implementation of a power system monitor for the Space Station Freedom PMAD DC testbed

    NASA Technical Reports Server (NTRS)

    Ludwig, Kimberly; Mackin, Michael; Wright, Theodore

    1991-01-01

    The Ada language software development to perform the electrical system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed is described. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electrical power system to be used in the Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 382/20e computers connected through an 802.4 local area network. One of these computers is designated as the control node with the other four acting as subsidiary controllers. The subsidiary controllers are connected to the power control components with a Mil-Std-1553 network. An operator interface is supplied by adding a sixth computer. The power system monitor algorithm is comprised of several functions including: periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data is collected from the switchgear sensors every 100 milliseconds, then passed through a 2 Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The reporting mechanism notifies an operator of any abnormalities in the system. Once per second, the system monitor provides data to the control node for further processing, such as state estimation. The system monitor required a hardware time interrupt to activate the data acquisition function. The execution time of the code was optimized using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities. A summary of the advantages and side effects of this technique are discussed.

  14. Features and application of wearable biosensors in medical care

    PubMed Central

    Ajami, Sima; Teimouri, Fotooheh

    2015-01-01

    One of the new technologies in the field of health is wearable biosensor, which provides vital signs monitoring of patients, athletes, premature infants, children, psychiatric patients, people who need long-term care, elderly, and people in impassable regions far from health and medical services. The aim of this study was to explain features and applications of wearable biosensors in medical services. This was a narrative review study that done in 2015. Search conducted with the help of libraries, books, conference proceedings, through databases of Science Direct, PubMed, Proquest, Springer, and SID (Scientific Information Database). In our searches, we employed the following keywords and their combinations; vital sign monitoring, medical smart shirt, smart clothing, wearable biosensors, physiological monitoring system, remote detection systems, remote control health, and bio-monitoring system. The preliminary search resulted in 54 articles, which published between 2002 and 2015. After a careful analysis of the content of each paper, 41 sources selected based on their relevancy. Although the use of wearable in healthcare is still in an infant stage, it could have a magic effect on healthcare. Smart wearable in the technology industry for 2015 is one that is looking to be a big and profitable market. Wearable biosensors capable of continuous vital signs monitoring and feedback to the user will be significantly effective in timely prevention, diagnosis, treatment, and control of diseases. PMID:26958058

  15. A fiber optic multi-stress monitoring system for power transformer

    NASA Astrophysics Data System (ADS)

    Kim, Dae-gil; Sampath, Umesh; Kim, Hyunjin; Song, Minho

    2017-04-01

    A fiber-optic multi-stress monitoring system which uses 4 FBG sensors and a fiber-optic mandrel acoustic emission sensor is proposed. FBG sensors and a mandrel sensor measure different types of stresses occurring in electrical power transformer, such as temperature and acoustic signals. The sensor system uses single broadband light source to address the outputs of both sensors using single fiber-optic circuitry. An athermal-packaged FBG is used to supply quasi-coherent light for the Sagnac interferometer demodulation which processes the mandrel sensor output. The proposed sensor system could simplify the optical circuit for the multi-stress measurements and enhance the cost-effectiveness of the sensor system.

  16. Structural Monitoring of Metro Infrastructure during Shield Tunneling Construction

    PubMed Central

    Ran, L.; Ye, X. W.; Ming, G.; Dong, X. B.

    2014-01-01

    Shield tunneling construction of metro infrastructure will continuously disturb the soils. The ground surface will be subjected to uplift or subsidence due to the deep excavation and the extrusion and consolidation of the soils. Implementation of the simultaneous monitoring with the shield tunnel construction will provide an effective reference in controlling the shield driving, while how to design and implement a safe, economic, and effective structural monitoring system for metro infrastructure is of great importance and necessity. This paper presents the general architecture of the shield construction of metro tunnels as well as the procedure of the artificial ground freezing construction of the metro-tunnel cross-passages. The design principles for metro infrastructure monitoring of the shield tunnel intervals in the Hangzhou Metro Line 1 are introduced. The detailed monitoring items and the specified alarming indices for construction monitoring of the shield tunneling are addressed, and the measured settlement variations at different monitoring locations are also presented. PMID:25032238

  17. Non-Contact Sensor for Long-Term Continuous Vital Signs Monitoring: A Review on Intelligent Phased-Array Doppler Sensor Design

    PubMed Central

    Hall, Travis; Nguyen, Tam Q.; Mayeda, Jill C.; Lie, Paul E.; Lopez, Jerry; Banister, Ron E.

    2017-01-01

    It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates) remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients’ long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient’s vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF) non-contact vital signs (NCVS) monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the subject is sleeping without hectic movements nearby. PMID:29140281

  18. Non-Contact Sensor for Long-Term Continuous Vital Signs Monitoring: A Review on Intelligent Phased-Array Doppler Sensor Design.

    PubMed

    Hall, Travis; Lie, Donald Y C; Nguyen, Tam Q; Mayeda, Jill C; Lie, Paul E; Lopez, Jerry; Banister, Ron E

    2017-11-15

    It has been the dream of many scientists and engineers to realize a non-contact remote sensing system that can perform continuous, accurate and long-term monitoring of human vital signs as we have seen in many Sci-Fi movies. Having an intelligible sensor system that can measure and record key vital signs (such as heart rates and respiration rates) remotely and continuously without touching the patients, for example, can be an invaluable tool for physicians who need to make rapid life-and-death decisions. Such a sensor system can also effectively help physicians and patients making better informed decisions when patients' long-term vital signs data is available. Therefore, there has been a lot of research activities on developing a non-contact sensor system that can monitor a patient's vital signs and quickly transmit the information to healthcare professionals. Doppler-based radio-frequency (RF) non-contact vital signs (NCVS) monitoring system are particularly attractive for long term vital signs monitoring because there are no wires, electrodes, wearable devices, nor any contact-based sensors involved so the subjects may not be even aware of the ubiquitous monitoring. In this paper, we will provide a brief review on some latest development on NCVS sensors and compare them against a few novel and intelligent phased-array Doppler-based RF NCVS biosensors we have built in our labs. Some of our NCVS sensor tests were performed within a clutter-free anechoic chamber to mitigate the environmental clutters, while most tests were conducted within the typical Herman-Miller type office cubicle setting to mimic a more practical monitoring environment. Additionally, we will show the measurement data to demonstrate the feasibility of long-term NCVS monitoring. The measured data strongly suggests that our latest phased array NCVS system should be able to perform long-term vital signs monitoring intelligently and robustly, especially for situations where the subject is sleeping without hectic movements nearby.

  19. Online monitoring of seismic damage in water distribution systems

    NASA Astrophysics Data System (ADS)

    Liang, Jianwen; Xiao, Di; Zhao, Xinhua; Zhang, Hongwei

    2004-07-01

    It is shown that water distribution systems can be damaged by earthquakes, and the seismic damages cannot easily be located, especially immediately after the events. Earthquake experiences show that accurate and quick location of seismic damage is critical to emergency response of water distribution systems. This paper develops a methodology to locate seismic damage -- multiple breaks in a water distribution system by monitoring water pressure online at limited positions in the water distribution system. For the purpose of online monitoring, supervisory control and data acquisition (SCADA) technology can well be used. A neural network-based inverse analysis method is constructed for locating the seismic damage based on the variation of water pressure. The neural network is trained by using analytically simulated data from the water distribution system, and validated by using a set of data that have never been used in the training. It is found that the methodology provides an effective and practical way in which seismic damage in a water distribution system can be accurately and quickly located.

  20. Faster response time, effective use of resources : integrating transportation systems and emergency management systems.

    DOT National Transportation Integrated Search

    1999-01-01

    When emergency services agencies share : facilities and traffic monitoring resources : with transportation management agencies, : the efficiency and speed of incident : response are measurably improved.

  1. Advanced laser stratospheric monitoring systems analyses

    NASA Technical Reports Server (NTRS)

    Larsen, J. C.

    1984-01-01

    This report describes the software support supplied by Systems and Applied Sciences Corporation for the study of Advanced Laser Stratospheric Monitoring Systems Analyses under contract No. NAS1-15806. This report discusses improvements to the Langley spectroscopic data base, development of LHS instrument control software and data analyses and validation software. The effect of diurnal variations on the retrieved concentrations of NO, NO2 and C L O from a space and balloon borne measurement platform are discussed along with the selection of optimum IF channels for sensing stratospheric species from space.

  2. Factors Affecting Mobile Diabetes Monitoring Adoption Among Physicians: Questionnaire Study and Path Model

    PubMed Central

    Castañeda, José Alberto; Sanz, Silvia; Henseler, Jörg

    2012-01-01

    Background Patients with type 1 and type 2 diabetes often find it difficult to control their blood glucose level on a daily basis because of distance or physical incapacity. With the increase in Internet-enabled smartphone use, this problem can be resolved by adopting a mobile diabetes monitoring system. Most existing studies have focused on patients’ usability perceptions, whereas little attention has been paid to physicians’ intentions to adopt this technology. Objective The aim of the study was to evaluate the perceptions and user acceptance of mobile diabetes monitoring among Japanese physicians. Methods A questionnaire survey of physicians was conducted in Japan. The structured questionnaire was prepared in a context of a mobile diabetes monitoring system that controls blood glucose, weight, physical activity, diet, insulin and medication, and blood pressure. Following a thorough description of mobile diabetes monitoring with a graphical image, questions were asked relating to system quality, information quality, service quality, health improvement, ubiquitous control, privacy and security concerns, perceived value, subjective norms, and intention to use mobile diabetes monitoring. The data were analyzed by partial least squares (PLS) path modeling. Results In total, 471 physicians participated from 47 prefectures across Japan, of whom 134 were specialized in internal and gastrointestinal medicine. Nine hypotheses were tested with both the total sample and the specialist subsample; results were similar for both samples in terms of statistical significance and the strength of path coefficients. We found that system quality, information quality, and service quality significantly affect overall quality. Overall quality determines the extent to which physicians perceive the value of mobile health monitoring. However, in contrast to our initial predictions, overall quality does not have a significant direct effect on the intention to use mobile diabetes monitoring. With regard to net benefits, both ubiquitous control and health improvement are significant predictors. Net benefits in turn significantly motivate physicians to use mobile health monitoring, and has a strong influence on perceived value. Perceived value and subjective norms are predictors of intention to use. In our sample, concerns over privacy and security risk have no significant effects on intention to use mobile diabetes monitoring. Among the 3 control variables, only age significantly affected intention to use mobile diabetes monitoring, whereas experience and gender were not significant predictors of intention. Conclusions Physicians consider perceived value and net benefits as the most important motivators to use mobile diabetes monitoring. Overall quality assessment does affect their intention to use this technology, but only indirectly through perceived value. Net benefits seem to be a strong driver in both a direct and indirect manner, implying that physicians may perceive health improvement with ubiquitous control as a true utility by enhancing cost-effective monitoring, and simultaneously recognize it as a way to create value for their clinical practices. PMID:23257115

  3. A Review of Diagnostic Techniques for ISHM Applications

    NASA Technical Reports Server (NTRS)

    Patterson-Hine, Ann; Biswas, Gautam; Aaseng, Gordon; Narasimhan, Sriam; Pattipati, Krishna

    2005-01-01

    System diagnosis is an integral part of any Integrated System Health Management application. Diagnostic applications make use of system information from the design phase, such as safety and mission assurance analysis, failure modes and effects analysis, hazards analysis, functional models, fault propagation models, and testability analysis. In modern process control and equipment monitoring systems, topological and analytic , models of the nominal system, derived from design documents, are also employed for fault isolation and identification. Depending on the complexity of the monitored signals from the physical system, diagnostic applications may involve straightforward trending and feature extraction techniques to retrieve the parameters of importance from the sensor streams. They also may involve very complex analysis routines, such as signal processing, learning or classification methods to derive the parameters of importance to diagnosis. The process that is used to diagnose anomalous conditions from monitored system signals varies widely across the different approaches to system diagnosis. Rule-based expert systems, case-based reasoning systems, model-based reasoning systems, learning systems, and probabilistic reasoning systems are examples of the many diverse approaches ta diagnostic reasoning. Many engineering disciplines have specific approaches to modeling, monitoring and diagnosing anomalous conditions. Therefore, there is no "one-size-fits-all" approach to building diagnostic and health monitoring capabilities for a system. For instance, the conventional approaches to diagnosing failures in rotorcraft applications are very different from those used in communications systems. Further, online and offline automated diagnostic applications are integrated into an operations framework with flight crews, flight controllers and maintenance teams. While the emphasis of this paper is automation of health management functions, striking the correct balance between automated and human-performed tasks is a vital concern.

  4. Electronic Monitoring Systems to Assess Urinary Incontinence: A Health Technology Assessment

    PubMed Central

    Nevis, Immaculate; Kabali, Conrad; Anh Tu, Hong; Ekanayake, Samanthika; Mistry, Jigna; Wells, David; Ali, Arshia; Walter, Melissa; Higgins, Caroline

    2018-01-01

    Background Urinary incontinence is involuntary leakage of urine and can affect people of all ages. Incidence rises as people age, often because of reduced mobility or conditions affecting the nervous system, such as dementia and stroke. Urinary incontinence can be a distressing condition and can harm a person's physical, financial, social, and emotional well-being. People with urinary incontinence are susceptible to skin irritation, pressure sores, and urinary tract infections. Urinary incontinence is also associated with an increased risk of falls in older adults. This health technology assessment examined the effectiveness of, budget impact of, and patient values and preferences about electronic monitoring systems to assess urinary incontinence for residents of long-term care homes or geriatric hospital inpatients with complex conditions. Methods A clinical evidence review of the published clinical literature was conducted to June 9, 2017. Critical appraisal of the clinical evidence included assessment of risk of bias and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria to reflect the certainty of the evidence. We calculated the funding required for an electronic urinary incontinence monitoring system in the first year of implementation (when facilities would buy the systems) and in subsequent years. We interviewed six people with urinary incontinence and two caregivers, who described ways urinary incontinence affected daily life. Results We included one observational study in the clinical review. Most of the 31 participants in the observational study were female (78%) and required high levels of care, primarily because of cognitive impairment. The quality of evidence for all outcomes was very low owing to potential risk of bias and indirectness. We are consequently uncertain about how electronic monitoring systems affect management of urinary incontinence. For patients living in long-term care homes who are eligible for the technology, we estimated that an electronic monitoring system to assess urinary incontinence would cost $6.4 million in the first year of implementation and $1.6 million in subsequent years. Patients said urinary incontinence reduced their independence and social life and adversely affected their quality of life. Incontinence made them embarrassed and reduced their self-esteem. Several respondents mentioned how expensive supplies to manage incontinence were. Conclusions The effectiveness of using the electronic monitoring system to assess urinary incontinence is uncertain because of the very low quality of the evidence. Introducing electronic monitoring systems would result in incremental costs, and there would be savings only if the systems substantially reduced incontinence. PMID:29844845

  5. Electronic Monitoring Systems to Assess Urinary Incontinence: A Health Technology Assessment.

    PubMed

    2018-01-01

    Urinary incontinence is involuntary leakage of urine and can affect people of all ages. Incidence rises as people age, often because of reduced mobility or conditions affecting the nervous system, such as dementia and stroke. Urinary incontinence can be a distressing condition and can harm a person's physical, financial, social, and emotional well-being. People with urinary incontinence are susceptible to skin irritation, pressure sores, and urinary tract infections. Urinary incontinence is also associated with an increased risk of falls in older adults.This health technology assessment examined the effectiveness of, budget impact of, and patient values and preferences about electronic monitoring systems to assess urinary incontinence for residents of long-term care homes or geriatric hospital inpatients with complex conditions. A clinical evidence review of the published clinical literature was conducted to June 9, 2017. Critical appraisal of the clinical evidence included assessment of risk of bias and the Grading of Recommendations Assessment, Development, and Evaluation (GRADE) Working Group criteria to reflect the certainty of the evidence.We calculated the funding required for an electronic urinary incontinence monitoring system in the first year of implementation (when facilities would buy the systems) and in subsequent years.We interviewed six people with urinary incontinence and two caregivers, who described ways urinary incontinence affected daily life. We included one observational study in the clinical review. Most of the 31 participants in the observational study were female (78%) and required high levels of care, primarily because of cognitive impairment. The quality of evidence for all outcomes was very low owing to potential risk of bias and indirectness. We are consequently uncertain about how electronic monitoring systems affect management of urinary incontinence.For patients living in long-term care homes who are eligible for the technology, we estimated that an electronic monitoring system to assess urinary incontinence would cost $6.4 million in the first year of implementation and $1.6 million in subsequent years.Patients said urinary incontinence reduced their independence and social life and adversely affected their quality of life. Incontinence made them embarrassed and reduced their self-esteem. Several respondents mentioned how expensive supplies to manage incontinence were. The effectiveness of using the electronic monitoring system to assess urinary incontinence is uncertain because of the very low quality of the evidence. Introducing electronic monitoring systems would result in incremental costs, and there would be savings only if the systems substantially reduced incontinence.

  6. Opportunities for improving the efficiency of paediatric HIV treatment programmes

    PubMed Central

    Revill, Paul A.; Walker, Simon; Mabugu, Travor; Nathoo, Kusum J.; Mugyenyi, Peter; Kekitinwa, Adeodata; Munderi, Paula; Bwakura-Dangarembizi, Mutsawashe; Musiime, Victor; Bakeera-Kitaka, Sabrina; Nahirya-Ntege, Patricia; Walker, A. Sarah; Sculpher, Mark J.; Gibb, Diana M.

    2015-01-01

    Objectives: To conduct two economic analyses addressing whether to: routinely monitor HIV-infected children on antiretroviral therapy (ART) clinically or with laboratory tests; continue or stop cotrimoxazole prophylaxis when children become stabilized on ART. Design and methods: The ARROW randomized trial investigated alternative strategies to deliver paediatric ART and cotrimoxazole prophylaxis in 1206 Ugandan/Zimbabwean children. Incremental cost-effectiveness and value of implementation analyses were undertaken. Scenario analyses investigated whether laboratory monitoring (CD4+ tests for efficacy monitoring; haematology/biochemistry for toxicity) could be tailored and targeted to be delivered cost-effectively. Cotrimoxazole use was examined in malaria-endemic and non-endemic settings. Results: Using all trial data, clinical monitoring delivered similar health outcomes to routine laboratory monitoring, but at a reduced cost, so was cost-effective. Continuing cotrimoxazole improved health outcomes at reduced costs. Restricting routine CD4+ monitoring to after 52 weeks following ART initiation and removing toxicity testing was associated with an incremental cost-effectiveness ratio of $6084 per quality-adjusted life-year (QALY) across all age groups, but was much lower for older children (12+ years at initiation; incremental cost-effectiveness ratio = $769/QALY). Committing resources to improve cotrimoxazole implementation appears cost-effective. A healthcare system that could pay $600/QALY should be willing to spend up to $12.0 per patient-year to ensure continued provision of cotrimoxazole. Conclusion: Clinically driven monitoring of ART is cost-effective in most circumstances. Routine laboratory monitoring is generally not cost-effective at current prices, except possibly CD4+ testing amongst adolescents initiating ART. Committing resources to ensure continued provision of cotrimoxazole in health facilities is more likely to represent an efficient use of resources. PMID:25396263

  7. Measuring the Hydraulic Effectiveness of Low Impact Development Practices in a Heavily Urbanised Environment: A Case Study from London, UK

    NASA Astrophysics Data System (ADS)

    El Hattab, M. H.; Vernon, D.; Mijic, A.

    2017-12-01

    Low impact development practices (LID) are deemed to have a synergetic effect in mitigating urban storm water flooding. Designing and implementing effective LID practices require reliable real-life data about their performance in different applications; however, there are limited studies providing such data. In this study an innovative micro-monitoring system to assess the performance of porous pavement and rain gardens as retrofitting technologies was developed. Three pilot streets in London, UK were selected as part of Thames Water Utilities Limited's Counters Creek scheme. The system includes a V-notch weir installed at the outlet of each LID device to provide an accurate and reliable quantification over a wide range of discharges. In addition to, a low flow sensor installed downstream of the V-notch to cross-check the readings. Having a flow survey time-series of the pre-retrofitting conditions from the study streets, extensive laboratory calibrations under different flow conditions depicting the exact site conditions were performed prior to installing the devices in the field. The micro-monitoring system is well suited for high-resolution temporal monitoring and enables accurate long-term evaluation of LID components' performance. Initial results from the field validated the robustness of the system in fulfilling its requirements.

  8. Wireless lysimeters for real-time online soil water monitoring

    USDA-ARS?s Scientific Manuscript database

    Identification of nitrate-nitrogen (NO3-N) in drainage water allows accessing the effectiveness of water quality management. A passive capillary wick-type lysimeter (PCAPs) was used to monitor water flux and NO3-N leached below the root zone under an irrigated cropping system. Wireless lysimeters we...

  9. Monitoring load distribution and fatigue cost estimates of heavy truck loads on Louisiana state bridges.

    DOT National Transportation Integrated Search

    2013-11-01

    The bridge in this study was evaluated and a monitoring system was installed to investigate the effects of heavy loads and : the cost of fatigue for bridges on state highways in Louisiana. Also, this study is used to respond to Louisiana Senate : Con...

  10. The integrated business information system: using automation to monitor cost-effectiveness of park operations

    Treesearch

    Dick Stanley; Bruce Jackson

    1995-01-01

    The cost-effectiveness of park operations is often neglected because information is laborious to compile. The information, however, is critical if we are to derive maximum benefit from scarce resources. This paper describes an automated system for calculating cost-effectiveness ratios with minimum effort using data from existing data bases.

  11. Development and Application of Direct Data Capture for Monitoring Medication Compliance in Clinical Trials.

    PubMed

    Kim, Eun-Young

    2017-10-01

    The monitoring of medication compliance in clinical trials is important but labor intensive. To check medication compliance in clinical trials, a system was developed, and its technical feasibility evaluated. The system consisted of three parts: a management part (clinical trial center database and a developed program), clinical trial investigator part (monitoring), and clinical trial participant part (personal digital assistant [PDA] with a barcode scanner). The system was tested with 20 participants for 2 weeks, and compliance was evaluated. This study developed a medication compliance monitoring system that used a PDA with a barcode scanner, which sent reminder/warning messages, logged medication barcode data, and provided compliance information to investigators. Registered participants received short message service (SMS) reminder/warning messages on their PDA and sent barcode data at the dosing time. The age range of the participants was 29 to 73 years. Five participants were <50 years old and 8 were ≥65 years old. The total mean compliance rate was 82.3%. The mean compliance rate was 83.1% in participants <65 years old and 81.1% in those ≥65 years old. The system was feasible, usable, and effective, even with elderly participants, for monitoring medication compliance in clinical trials using a PDA with a barcode scanner, and may improve the quality of clinical trials.

  12. [Designing and implementation of a web-based quality monitoring system for plasma glucose measurement in multicenter population study].

    PubMed

    Liu, Yong; Wang, Limin; Pang, Richard; Mo, Nanxun; Hu, Yan; Deng, Qian; Hu, Zhaohui

    2015-05-01

    The aim of this paper is to describe the designing and implementation of a web-based plasma glucose measurement quality monitoring system to assess the analytical quality of plasma glucose measurements in multicenter population study and provide evidence for the future studies. In the chronic non-communicable disease and related factor surveillance in China, a web based quality monitoring system for plasma glucose measurement was established to conduct evaluation on plasma glucose monitoring quality and effectiveness in 302 surveillance centers, including quality control data entry, transmission and feedback. The majority of the surveillance centers met the quality requirements and passed the evaluation of reproducibility and precision of plasma glucose measurement, only a few centers required intensive training and re-assessment. In order to ensure the completeness and reliability of plasma glucose measurement in the surveillance centers, the establishment of web-based plasma glucose measurement quality control system can facilitate the identification of the qualified surveillance centers and evaluation of plasma glucose measurement quality in different regions. Communication and training are important in ensuring plasma glucose measurement quality. It is necessary to further improve this web-based plasma glucose measurement quality monitoring system in the future to reduce the method specific plasma glucose measurement bias.

  13. Monitoring trail conditions: New methodological considerations

    USGS Publications Warehouse

    Marion, Jeffrey L.; Leung, Yu-Fai; Nepal, Sanjay K.

    2006-01-01

    The U.S. National Park Service (NPS) accommodates nearly 300 million visitors per year, visitation that has the potential to produce negative effects on fragile natural and cultural resources. The policy guidance from the NPS Management Policies recognizes the legitimacy of providing opportunities for public enjoyment of parks while acknowledging the need for managers to “seek ways to avoid, or to minimize to the greatest degree practicable, adverse impacts on park resources and values” (NPS 2001). Thus, relative to visitor use, park managers must evaluate the types and extents of resource impacts associated with recreational activities, and determine to what extent they are unacceptable and constitute impairment. Visitor impact monitoring programs can assist managers in making objective evaluations of impact acceptability and impairment and in selecting effective impact management practices by providing quantitative documentation of the types and extent of recreationrelated impacts on natural resources. Monitoring programs are explicitly authorized in Section 4.1 of the Management Policies: Natural systems in the national park system, and the human influences upon them, will be monitored to detect change. The Service will use the results of monitoring and research to understand the detected change and to develop appropriate management actions.

  14. Simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in humans and other animal models using a single light source

    NASA Astrophysics Data System (ADS)

    Dent, Paul; Tun, Sai Han; Fillioe, Seth; Deng, Bin; Satalin, Josh; Nieman, Gary; Wilcox, Kailyn; Searles, Quinn; Narsipur, Sri; Peterson, Charles M.; Goodisman, Jerry; Mostrom, James; Steinmann, Richard; Chaiken, J.

    2018-02-01

    We previously reported a new algorithm "PV[O]H" for continuous, noninvasive, in vivo monitoring of hematocrit changes in blood and have since shown its utility for monitoring in humans during 1) hemodialysis, 2) orthostatic perturbations and 3) during blood loss and fluid replacement in a rat model. We now show that the algorithm is sensitive to changes in hemoglobin oxygen saturation. We document the phenomenology of the effect and explain the effect using new results obtained from humans and rat models. The oxygen sensitivity derives from the differential absorption of autofluorescence originating in the static tissues by oxy and deoxy hemoglobin. Using this approach we show how to perform simultaneous, noninvasive, in vivo, continuous monitoring of hematocrit, vascular volume, hemoglobin oxygen saturation, pulse rate and breathing rate in mammals using a single light source. We suspect that monitoring of changes in this suite of vital signs can be provided with improved time response, sensitivity and precision compared to existing methodologies. Initial results also offer a more detailed glimpse into the systemic oxygen transport in the circulatory system of humans.

  15. Towards a Low-Cost Real-Time Photogrammetric Landslide Monitoring System Utilising Mobile and Cloud Computing Technology

    NASA Astrophysics Data System (ADS)

    Chidburee, P.; Mills, J. P.; Miller, P. E.; Fieber, K. D.

    2016-06-01

    Close-range photogrammetric techniques offer a potentially low-cost approach in terms of implementation and operation for initial assessment and monitoring of landslide processes over small areas. In particular, the Structure-from-Motion (SfM) pipeline is now extensively used to help overcome many constraints of traditional digital photogrammetry, offering increased user-friendliness to nonexperts, as well as lower costs. However, a landslide monitoring approach based on the SfM technique also presents some potential drawbacks due to the difficulty in managing and processing a large volume of data in real-time. This research addresses the aforementioned issues by attempting to combine a mobile device with cloud computing technology to develop a photogrammetric measurement solution as part of a monitoring system for landslide hazard analysis. The research presented here focusses on (i) the development of an Android mobile application; (ii) the implementation of SfM-based open-source software in the Amazon cloud computing web service, and (iii) performance assessment through a simulated environment using data collected at a recognized landslide test site in North Yorkshire, UK. Whilst the landslide monitoring mobile application is under development, this paper describes experiments carried out to ensure effective performance of the system in the future. Investigations presented here describe the initial assessment of a cloud-implemented approach, which is developed around the well-known VisualSFM algorithm. Results are compared to point clouds obtained from alternative SfM 3D reconstruction approaches considering a commercial software solution (Agisoft PhotoScan) and a web-based system (Autodesk 123D Catch). Investigations demonstrate that the cloud-based photogrammetric measurement system is capable of providing results of centimeter-level accuracy, evidencing its potential to provide an effective approach for quantifying and analyzing landslide hazard at a local-scale.

  16. GTSO: Global Trace Synchronization and Ordering Mechanism for Wireless Sensor Network Monitoring Platforms.

    PubMed

    Navia, Marlon; Campelo, José Carlos; Bonastre, Alberto; Ors, Rafael

    2017-12-23

    Monitoring is one of the best ways to evaluate the behavior of computer systems. When the monitored system is a distributed system-such as a wireless sensor network (WSN)-the monitoring operation must also be distributed, providing a distributed trace for further analysis. The temporal sequence of occurrence of the events registered by the distributed monitoring platform (DMP) must be correctly established to provide cause-effect relationships between them, so the logs obtained in different monitor nodes must be synchronized. Many of synchronization mechanisms applied to DMPs consist in adjusting the internal clocks of the nodes to the same value as a reference time. However, these mechanisms can create an incoherent event sequence. This article presents a new method to achieve global synchronization of the traces obtained in a DMP. It is based on periodic synchronization signals that are received by the monitor nodes and logged along with the recorded events. This mechanism processes all traces and generates a global post-synchronized trace by scaling all times registered proportionally according with the synchronization signals. It is intended to be a simple but efficient offline mechanism. Its application in a WSN-DMP demonstrates that it guarantees a correct ordering of the events, avoiding the aforementioned issues.

  17. Practical method for appearance match between soft copy and hard copy

    NASA Astrophysics Data System (ADS)

    Katoh, Naoya

    1994-04-01

    CRT monitors are often used as a soft proofing device for the hard copy image output. However, what the user sees on the monitor does not match its output, even if the monitor and the output device are calibrated with CIE/XYZ or CIE/Lab. This is especially obvious when correlated color temperature (CCT) of CRT monitor's white point significantly differs from ambient light. In a typical office environment, one uses a computer graphic monitor having a CCT of 9300K in a room of white fluorescent light of 4150K CCT. In such a case, human visual system is partially adapted to the CRT monitor's white point and partially to the ambient light. The visual experiments were performed on the effect of the ambient lighting. Practical method for soft copy color reproduction that matches the hard copy image in appearance is presented in this paper. This method is fundamentally based on a simple von Kries' adaptation model and takes into account the human visual system's partial adaptation and contrast matching.

  18. Physics Simulation Software for Autonomous Propellant Loading and Gas House Autonomous System Monitoring

    NASA Technical Reports Server (NTRS)

    Regalado Reyes, Bjorn Constant

    2015-01-01

    1. Kennedy Space Center (KSC) is developing a mobile launching system with autonomous propellant loading capabilities for liquid-fueled rockets. An autonomous system will be responsible for monitoring and controlling the storage, loading and transferring of cryogenic propellants. The Physics Simulation Software will reproduce the sensor data seen during the delivery of cryogenic fluids including valve positions, pressures, temperatures and flow rates. The simulator will provide insight into the functionality of the propellant systems and demonstrate the effects of potential faults. This will provide verification of the communications protocols and the autonomous system control. 2. The High Pressure Gas Facility (HPGF) stores and distributes hydrogen, nitrogen, helium and high pressure air. The hydrogen and nitrogen are stored in cryogenic liquid state. The cryogenic fluids pose several hazards to operators and the storage and transfer equipment. Constant monitoring of pressures, temperatures and flow rates are required in order to maintain the safety of personnel and equipment during the handling and storage of these commodities. The Gas House Autonomous System Monitoring software will be responsible for constantly observing and recording sensor data, identifying and predicting faults and relaying hazard and operational information to the operators.

  19. Chickamauga Reservoir 1992 fisheries monitoring cove rotenone results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerley, B.L.

    1993-06-01

    The Tennessee Valley Authority (TVA) is required by the National Pollutant Discharge Elimination System (NPDES) Permit for Sequoyah Nuclear Plant (SQN) to conduct and report annually a nonradiological operational monitoring program to evaluate potential effects of SQN on Chickamauga Reservoir. This monitoring program was initially designed to identify potential changes in water quality and biological communities in Chickamauga Reservoir resulting from operation of SQU. Chickamauga Reservoir cove rotenone sampling has also been conducted as part of the preoperational monitoring program for Watts Bar Nuclear Plant (WBN) to evaluate the combined effects of operating two nuclear facilities on one reservoir oncemore » WBU becomes operational. The purpose of this report is to present results of cove rotenone sampling conducted on Chickamauga Reservoir in 1992.« less

  20. 40 CFR 142.307 - What terms and conditions must be included in a small system variance?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... that may affect proper and effective operation and maintenance of the technology; (2) Monitoring... effective installation, operation and maintenance of the applicable small system variance technology in... health, which may include: (i) Public education requirements; and (ii) Source water protection...

  1. Pervasive mobile healthcare systems for chronic disease monitoring.

    PubMed

    Huzooree, Geshwaree; Kumar Khedo, Kavi; Joonas, Noorjehan

    2017-05-01

    Pervasive mobile healthcare system has the potential to improve healthcare and the quality of life of chronic disease patients through continuous monitoring. Recently, many articles related to pervasive mobile healthcare system focusing on health monitoring using wireless technologies have been published. The main aim of this review is to evaluate the state-of-the-art pervasive mobile healthcare systems to identify major technical requirements and design challenges associated with the realization of a pervasive mobile healthcare system. A systematic literature review was conducted over IEEE Xplore Digital Library to evaluate 20 pervasive mobile healthcare systems out of 683 articles from 2011 to 2016. The classification of the pervasive mobile healthcare systems and other important factors are discussed. Potential opportunities and challenges are pointed out for the further deployment of effective pervasive mobile healthcare systems. This article helps researchers in health informatics to have a holistic view toward understanding pervasive mobile healthcare systems and points out new technological trends and design challenges that researchers have to consider when designing such systems for better adoption, usability, and seamless integration.

  2. Fault tree analysis for data-loss in long-term monitoring networks.

    PubMed

    Dirksen, J; ten Veldhuis, J A E; Schilperoort, R P S

    2009-01-01

    Prevention of data-loss is an important aspect in the design as well as the operational phase of monitoring networks since data-loss can seriously limit intended information yield. In the literature limited attention has been paid to the origin of unreliable or doubtful data from monitoring networks. Better understanding of causes of data-loss points out effective solutions to increase data yield. This paper introduces FTA as a diagnostic tool to systematically deduce causes of data-loss in long-term monitoring networks in urban drainage systems. In order to illustrate the effectiveness of FTA, a fault tree is developed for a monitoring network and FTA is applied to analyze the data yield of a UV/VIS submersible spectrophotometer. Although some of the causes of data-loss cannot be recovered because the historical database of metadata has been updated infrequently, the example points out that FTA still is a powerful tool to analyze the causes of data-loss and provides useful information on effective data-loss prevention.

  3. Cost-Utility Analysis of the EVOLVO Study on Remote Monitoring for Heart Failure Patients With Implantable Defibrillators: Randomized Controlled Trial

    PubMed Central

    Landolina, Maurizio; Marzegalli, Maurizio; Lunati, Maurizio; Perego, Giovanni B; Guenzati, Giuseppe; Curnis, Antonio; Valsecchi, Sergio; Borghetti, Francesca; Borghi, Gabriella; Masella, Cristina

    2013-01-01

    Background Heart failure patients with implantable defibrillators place a significant burden on health care systems. Remote monitoring allows assessment of device function and heart failure parameters, and may represent a safe, effective, and cost-saving method compared to conventional in-office follow-up. Objective We hypothesized that remote device monitoring represents a cost-effective approach. This paper summarizes the economic evaluation of the Evolution of Management Strategies of Heart Failure Patients With Implantable Defibrillators (EVOLVO) study, a multicenter clinical trial aimed at measuring the benefits of remote monitoring for heart failure patients with implantable defibrillators. Methods Two hundred patients implanted with a wireless transmission–enabled implantable defibrillator were randomized to receive either remote monitoring or the conventional method of in-person evaluations. Patients were followed for 16 months with a protocol of scheduled in-office and remote follow-ups. The economic evaluation of the intervention was conducted from the perspectives of the health care system and the patient. A cost-utility analysis was performed to measure whether the intervention was cost-effective in terms of cost per quality-adjusted life year (QALY) gained. Results Overall, remote monitoring did not show significant annual cost savings for the health care system (€1962.78 versus €2130.01; P=.80). There was a significant reduction of the annual cost for the patients in the remote arm in comparison to the standard arm (€291.36 versus €381.34; P=.01). Cost-utility analysis was performed for 180 patients for whom QALYs were available. The patients in the remote arm gained 0.065 QALYs more than those in the standard arm over 16 months, with a cost savings of €888.10 per patient. Results from the cost-utility analysis of the EVOLVO study show that remote monitoring is a cost-effective and dominant solution. Conclusions Remote management of heart failure patients with implantable defibrillators appears to be cost-effective compared to the conventional method of in-person evaluations. Trial Registration ClinicalTrials.gov NCT00873899; http://clinicaltrials.gov/show/NCT00873899 (Archived by WebCite at http://www.webcitation.org/6H0BOA29f). PMID:23722666

  4. Monitoring biological effects of contamination in marine fish along French coasts by measurement of ethoxyresorufin-O-deethylase activity.

    PubMed

    Burgeot, T; Bocquené, G; Pingray, G; Godefroy, D; Legrand, J; Dimeet, J; Marco, F; Vincent, F; Henocque, Y; Jeanneret, H O

    1994-11-01

    The use of bioindicators to evaluate exposure to the biological effects of chemical pollutants in marine organisms constitutes a new tool in the monitoring field. The establishment of a North Sea monitoring network in 1991, involving such international organizations as the North Sea Task Force, the International Council for the Exploration of the Sea, and the Intergovernmental Oceanography Commission, led French researchers to develop an enzymatic biomarker to monitor biological effects within the National Observation Network. The biomarker, ethoxyresorufin-O-deethylase (EROD), dependent on the CP450 system, has been monitored biannually since 1992 in several species of fish (Callionymus lyra, Limanda limanda, Serranus sp., Mullus barbatus) in two coastal sites particularly exposed to industrial and domestic pollution. A rapid method is used to assay EROD enzymatic activity determined along a pollution gradient, and results are interpreted on a microplate reader. The strategy of this approach is to assess the effects on the marine ecosystem during prolonged exposure to specific pollutants such as polyaromatic hydrocarbons, polychlorinated biphenyls, and dioxins.

  5. Design of Plant Eco-physiology Monitoring System Based on Embedded Technology

    NASA Astrophysics Data System (ADS)

    Li, Yunbing; Wang, Cheng; Qiao, Xiaojun; Liu, Yanfei; Zhang, Xinlu

    A real time system has been developed to collect plant's growth information comprehensively. Plant eco-physiological signals can be collected and analyzed effectively. The system adopted embedded technology: wireless sensors network collect the eco-physiological information. Touch screen and ARM microprocessor make the system work independently without PC. The system is versatile and all parameters can be set by the touch screen. Sensors' intelligent compensation can be realized in this system. Information can be displayed by either graphically or in table mode. The ARM microprocessor provides the interface to connect with the internet, so the system support remote monitoring and controlling. The system has advantages of friendly interface, flexible construction and extension. It's a good tool for plant's management.

  6. Impact of remote monitoring on the management of arrhythmias in patients with implantable cardioverter-defibrillator.

    PubMed

    Marcantoni, Lina; Toselli, Tiziano; Urso, Giulia; Pratola, Claudio; Ceconi, Claudio; Bertini, Matteo

    2015-11-01

    In the last decade, there has been an exponential increase in cardioverter-defibrillator (ICD) implants. Remote monitoring systems, allow daily follow-ups of patients with ICD. To evaluate the impact of remote monitoring on the management of cardiovascular events associated with supraventricular and ventricular arrhythmias during long-term follow-up. A total of 207 patients undergoing ICD implantation/replacement were enrolled: 79 patients received remote monitoring systems and were followed up every 12 months, and 128 patients were followed up conventionally every 6 months. All patients were followed up and monitored for the occurrence of supraventricular and ventricular arrhythmia-related cardiovascular events (ICD shocks and/or hospitalizations). During a median follow-up of 842 days (interquartile range 476-1288 days), 32 (15.5%) patients experienced supraventricular arrhythmia-related events and 51 (24.6%) patients experienced ventricular arrhythmia-related events. Remote monitoring had a significant role in the reduction of supraventricular arrhythmia-related events, but it had no effect on ventricular arrhythmia-related events. In multivariable analysis, remote monitoring remained as an independent protective factor, reducing the risk of supraventricular arrhythmia-related events of 67% [hazard ratio, 0.33; 95% confidence interval (CI), 0.13-0.82; P = 0.017]. Remote monitoring systems improved outcomes in patients with supraventricular arrhythmias by reducing the risk of cardiovascular events, but no benefits were observed in patients with ventricular arrhythmias.

  7. Zebrafish as a model system to study toxicology.

    PubMed

    Dai, Yu-Jie; Jia, Yong-Fang; Chen, Na; Bian, Wan-Ping; Li, Qin-Kai; Ma, Yan-Bo; Chen, Yan-Ling; Pei, De-Sheng

    2014-01-01

    Monitoring and assessing the effects of contaminants in the aquatic eco-environment is critical in protecting human health and the environment. The zebrafish has been widely used as a prominent model organism in different fields because of its small size, low cost, diverse adaptability, short breeding cycle, high fecundity, and transparent embryos. Recent studies have demonstrated that zebrafish sensitivity can aid in monitoring environmental contaminants, especially with the application of transgenic technology in this area. The present review provides a brief overview of recent studies on wild-type and transgenic zebrafish as a model system to monitor toxic heavy metals, endocrine disruptors, and organic pollutants for toxicology. The authors address the new direction of developing high-throughput detection of genetically modified transparent zebrafish to open a new window for monitoring environmental pollutants. © 2013 SETAC.

  8. Development of a novel remote patient monitoring system: the advanced symptom management system for radiotherapy to improve the symptom experience of patients with lung cancer receiving radiotherapy.

    PubMed

    Maguire, Roma; Ream, Emma; Richardson, Alison; Connaghan, John; Johnston, Bridget; Kotronoulas, Grigorios; Pedersen, Vibe; McPhelim, John; Pattison, Natalie; Smith, Allison; Webster, Lorraine; Taylor, Anne; Kearney, Nora

    2015-01-01

    The use of technology-enhanced patient-reported outcome measures to monitor the symptoms experienced by people with cancer is an effective way to offer timely care. This study aimed to (a) explore the feasibility and acceptability of the Advanced Symptom Management System with patients with lung cancer receiving radiotherapy and clinicians involved in their care and (b) assess changes in patient outcomes during implementation of the Advanced Symptom Management System with patients with lung cancer receiving radiotherapy in clinical practice. A repeated-measures, single-arm, mixed-methods study design was used involving poststudy interviews and completion of patient-reported outcome measures at baseline and end of treatment with 16 patients with lung cancer and 13 clinicians who used this mobile phone-based symptom monitoring system. Only rarely did patients report problems in using the handset and they felt that the system covered all relevant symptoms and helped them to manage their symptoms and effectively communicate with clinicians. Clinical improvements in patient anxiety, drowsiness, and self-care self-efficacy were also observed. Clinicians perceived the use of "real-time" risk algorithms and automated self-care advice provided to patients as positively contributing to clinical care. Reducing the complexity of the system was seen as important to promote its utility. Although preliminary, these results suggest that monitoring patient symptoms using mobile technology in the context of radiotherapy for lung cancer is feasible and acceptable in clinical practice. Future research would be most beneficial if the use of this technology was focused on the postradiotherapy phase and expanded the scope of the system to encompass a wider range of supportive care needs.

  9. Critical aspects of integrated monitoring systems for landslides risk management: strategies for a reliable approach

    NASA Astrophysics Data System (ADS)

    Castagnetti, C.; Bertacchini, E.; Capra, A.; Corsini, A.

    2012-04-01

    The use of advanced technologies for remotely monitor surface processes is a successful way for improving the knowledge of phenomena evolution. In addition, the integration of various techniques is becoming more and more common in order to implement early warning systems that can monitor the evolution of landslides in time and prevent emergencies. The reliability of those systems plays a key role when Public Administrations have to plan actions in case of disasters or for preventing an incoming emergency. To have confidence in the information given by the system is an essential condition for a successful policy aiming to protect the population. The research deals with the major critical aspects to be taken into account when implementing a reliable monitoring system for unstable slopes. The importance of those aspects is often neglected, unlike the effects of a not careful implementation and management of the system can lead to erroneous interpretations of the phenomenon itself. The case study which ruled the research and highlighted the actual need of guidelines for setting up a reliable monitoring system is the Valoria landslide, located in the Northern Italy. The system is based on the integration of an automatic Total Station (TS) measuring 45 reflectors and a master GPS, acting as the reference station for three rovers placed within the landslide. In order to monitor local disturbing effects, a bi-dimensional clinometer has been applied on the TS pillar. Topographic measurements have been also integrated with geotechnical sensors (inclinometers and piezometers) in a GIS for landslide risk management. At the very beginning, periodic measurements were carried out, while the system is now performing continuously since 2008. The system permitted to evaluate movements from few millimeter till some meters per day in most dangerous areas. A more spatially continuous description has been also provided by LiDAR and terrestrial SAR interferometry. Some of the most interesting and critical aspects that will be deeper described and analyzed are: - strategy for planning a successful integrated system for continuous monitoring. - Choice of the reference frame: local coordinate system or georeferenced one. - Stability of the site for the master unit positioning: GPS time series analysis for controlling the effective stability. Thanks to the GPS master station that are operating for over three years, atmospheric disturbances affecting the signal may be removed in order to carefully verify the stability of the area and to establish whether the site is geologically stable, as originally suggested, or not. In the latter case, the magnitude of movements may also be computed for providing corrections to TS observations. - Stability of the monumentation, both for reference points and TS pillar. This is an essential aspect for avoiding misinterpretations when analyzing displacements of prisms placed within the landslide. The results of experiences carried out by Authors over last years about different landslides will be presented in order to propose guidelines for a sort of procedure aiming to increase the reliability of the information provided by the system and the usefulness for local Agencies.

  10. Monitoring Indoor Air Quality for Enhanced Occupational Health.

    PubMed

    Pitarma, Rui; Marques, Gonçalo; Ferreira, Bárbara Roque

    2017-02-01

    Indoor environments are characterized by several pollutant sources. Because people spend more than 90% of their time in indoor environments, several studies have pointed out the impact of indoor air quality on the etiopathogenesis of a wide number of non-specific symptoms which characterizes the "Sick Building Syndrome", involving the skin, the upper and lower respiratory tract, the eyes and the nervous system, as well as many building related diseases. Thus, indoor air quality (IAQ) is recognized as an important factor to be controlled for the occupants' health and comfort. The majority of the monitoring systems presently available is very expensive and only allow to collect random samples. This work describes the system (iAQ), a low-cost indoor air quality monitoring wireless sensor network system, developed using Arduino, XBee modules and micro sensors, for storage and availability of monitoring data on a web portal in real time. Five micro sensors of environmental parameters (air temperature, humidity, carbon monoxide, carbon dioxide and luminosity) were used. Other sensors can be added for monitoring specific pollutants. The results reveal that the system can provide an effective indoor air quality assessment to prevent exposure risk. In fact, the indoor air quality may be extremely different compared to what is expected for a quality living environment. Systems like this would have benefit as public health interventions to reduce the burden of symptoms and diseases related to "sick buildings".

  11. 40 CFR 75.16 - Special provisions for monitoring emissions from common, bypass, and multiple stacks for SO2...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... maintain an SO2 continuous emission monitoring system and flow monitoring system in the duct to the common... emission monitoring system and flow monitoring system in the common stack and combine emissions for the... continuous emission monitoring system and flow monitoring system in the duct to the common stack from each...

  12. Evaluation of the response of tritium-in-air instrumentation to HT in dry and humid conditions and to HTO vapor

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Phillips, H.; Dean, J.; Privas, E.

    2015-03-15

    Nuclear plant operators (power generation, decommissioning and reprocessing operations) are required to monitor releases of tritium species for regulatory compliance and radiation protection purposes. Tritium monitoring is performed using tritium-in-air gas monitoring instrumentation based either on flow-through ion chambers or proportional counting systems. Tritium-in-air monitors are typically calibrated in dry conditions but in service may operate at elevated levels of relative humidity. The NPL (National Physical Laboratory) radioactive gas-in-air calibration system has been used to study the effect of humidity on the response to tritium of two tritium-in-air ion chamber based monitors and one proportional counting system which uses amore » P10/air gas mixture. The response of these instruments to HTO vapour has also been evaluated. In each case, instrument responses were obtained for HT in dry conditions (relative humidity (RH) about 2%), HT in 45% RH, and finally HTO at 45% RH. Instrumentation response to HT in humid conditions has been found to slightly exceed that in dry conditions. (authors)« less

  13. Process Monitoring Evaluation and Implementation for the Wood Abrasive Machining Process

    PubMed Central

    Saloni, Daniel E.; Lemaster, Richard L.; Jackson, Steven D.

    2010-01-01

    Wood processing industries have continuously developed and improved technologies and processes to transform wood to obtain better final product quality and thus increase profits. Abrasive machining is one of the most important of these processes and therefore merits special attention and study. The objective of this work was to evaluate and demonstrate a process monitoring system for use in the abrasive machining of wood and wood based products. The system developed increases the life of the belt by detecting (using process monitoring sensors) and removing (by cleaning) the abrasive loading during the machining process. This study focused on abrasive belt machining processes and included substantial background work, which provided a solid base for understanding the behavior of the abrasive, and the different ways that the abrasive machining process can be monitored. In addition, the background research showed that abrasive belts can effectively be cleaned by the appropriate cleaning technique. The process monitoring system developed included acoustic emission sensors which tended to be sensitive to belt wear, as well as platen vibration, but not loading, and optical sensors which were sensitive to abrasive loading. PMID:22163477

  14. Engine monitoring display study

    NASA Technical Reports Server (NTRS)

    Hornsby, Mary E.

    1992-01-01

    The current study is part of a larger NASA effort to develop displays for an engine-monitoring system to enable the crew to monitor engine parameter trends more effectively. The objective was to evaluate the operational utility of adding three types of information to the basic Boeing Engine Indicating and Crew Alerting System (EICAS) display formats: alphanumeric alerting messages for engine parameters whose values exceed caution or warning limits; alphanumeric messages to monitor engine parameters that deviate from expected values; and a graphic depiction of the range of expected values for current conditions. Ten training and line pilots each flew 15 simulated flight scenarios with five variants of the basic EICAS format; these variants included different combinations of the added information. The pilots detected engine problems more quickly when engine alerting messages were included in the display; adding a graphic depiction of the range of expected values did not affect detection speed. The pilots rated both types of alphanumeric messages (alert and monitor parameter) as more useful and easier to interpret than the graphic depiction. Integrating engine parameter messages into the EICAS alerting system appears to be both useful and preferred.

  15. Application of Remote Sensing for Forest Management in Nepal

    NASA Astrophysics Data System (ADS)

    Bajracharya, B.; Matin, M. A.

    2016-12-01

    Large area of the Hindu Kush Himalayan (HKH) region is covered by forest that is playing a vital role to address the challenges of climate change and livelihood options for a growing population. Effective management of forest cover needs establishment of regular monitoring system for forest. Supporting REDD assessment needs reliable baseline assessment of forest biomass and its monitoring at multiple scale. Adaptation of forest to climate change needs understanding vulnerability of forests and dependence of local communities on these forest. We present here different forest monitoring products developed under the SERVIR-Himalaya programme to address these issues. Landsat 30 meter images were used for decadal land cover change assessment and annual forest change hotspot monitoring. Methodology developed for biomass estimation at national and sub-national level biomass estimation. Decision support system was developed for analysis of forest vulnerability and dependence and selection of adaptation options based on resource availability. These products are forming the basis for development of an integrated system that will be very useful for comprehensive forest monitoring and long term strategy development for sustainable forest management.

  16. Compilation of 1986 annual reports of the Navy ELF (Extremely Low Frequency) communications system ecological monitoring program, volume 2

    NASA Astrophysics Data System (ADS)

    1987-07-01

    The U.S. Navy is conducting a long-term program to monitor for possible effects from the operation of its Extremely Low Frequency (ELF) Communications System to resident biota and their ecological relationships. This report documents progress of the following studies: soil amoeba; soil and litter arthropoda and earthworm studies; biological studies on pollinating insects: megachilid bees; and small vertebrates: small mammals and nesting birds.

  17. Improvement of statistical methods for detecting anomalies in climate and environmental monitoring systems

    NASA Astrophysics Data System (ADS)

    Yakunin, A. G.; Hussein, H. M.

    2018-01-01

    The article shows how the known statistical methods, which are widely used in solving financial problems and a number of other fields of science and technology, can be effectively applied after minor modification for solving such problems in climate and environment monitoring systems, as the detection of anomalies in the form of abrupt changes in signal levels, the occurrence of positive and negative outliers and the violation of the cycle form in periodic processes.

  18. Objective for monitoring the corona discharge

    NASA Astrophysics Data System (ADS)

    Obrezkov, Andrey; Rodionov, Andrey Yu.; Pisarev, Viktor N.; Chivanov, Alexsey N.; Baranov, Yuri P.; Korotaev, Valery V.

    2016-04-01

    Remote optoelectronic probing is one of the most actual aspects of overhead electric line maintenances. By installing such systems on a helicopter (for example) it becomes possible to monitor overhead transmission line status and to search damaged parts of the lines. Thermal and UV-cameras are used for more effective diagnostic. UV-systems are fitted with filters, that attenuate visible spectrum, which is an undesired type of signal. Also these systems have a wide view angle for better view and proper diagnostics. For even more effectiveness, it is better to use several spectral channels: like UV and IR. Such spectral selection provides good noise reduction. Experimental results of spectral parameters of the wide view angle multispectral objective for such systems are provided in this report. There is also data on point spread function, UV and IR scattering index data and technical requirements for detectors.

  19. Diagnostics of wear in aeronautical systems

    NASA Technical Reports Server (NTRS)

    Wedeven, L. D.

    1979-01-01

    The use of appropriate diagnostic tools for aircraft oil wetted components is reviewed, noting that it can reduce direct operating costs through reduced unscheduled maintenance, particularly in helicopter engine and transmission systems where bearing failures are a significant cost factor. Engine and transmission wear modes are described, and diagnostic methods for oil and wet particle analysis, the spectrometric oil analysis program, chip detectors, ferrography, in-line oil monitor and radioactive isotope tagging are discussed, noting that they are effective over a limited range of particle sizes but compliment each other if used in parallel. Fine filtration can potentially increase time between overhauls, but reduces the effectiveness of conventional oil monitoring techniques so that alternative diagnostic techniques must be used. It is concluded that the development of a diagnostic system should be parallel and integral with the development of a mechanical system.

  20. Effective Hamiltonian approach to the Kerr nonlinearity in an optomechanical system

    NASA Astrophysics Data System (ADS)

    Gong, Z. R.; Ian, H.; Liu, Yu-Xi; Sun, C. P.; Nori, Franco

    2009-12-01

    Using the Born-Oppenheimer approximation, we derive an effective Hamiltonian for an optomechanical system that leads to a nonlinear Kerr effect in the system’s vacuum. The oscillating mirror at one edge of the optomechanical system induces a squeezing effect in the intensity spectrum of the cavity field. A near-resonant laser field is applied at the other edge to drive the cavity field in order to enhance the Kerr effect. We also propose a quantum-nondemolition-measurement setup to monitor a system with two cavities separated by a common oscillating mirror based on our effective Hamiltonian approach.

  1. SHARP: A multi-mission artificial intelligence system for spacecraft telemetry monitoring and diagnosis

    NASA Technical Reports Server (NTRS)

    Lawson, Denise L.; James, Mark L.

    1989-01-01

    The Spacecraft Health Automated Reasoning Prototype (SHARP) is a system designed to demonstrate automated health and status analysis for multi-mission spacecraft and ground data systems operations. Telecommunications link analysis of the Voyager 2 spacecraft is the initial focus for the SHARP system demonstration which will occur during Voyager's encounter with the planet Neptune in August, 1989, in parallel with real time Voyager operations. The SHARP system combines conventional computer science methodologies with artificial intelligence techniques to produce an effective method for detecting and analyzing potential spacecraft and ground systems problems. The system performs real time analysis of spacecraft and other related telemetry, and is also capable of examining data in historical context. A brief introduction is given to the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory. The current method of operation for monitoring the Voyager Telecommunications subsystem is described, and the difficulties associated with the existing technology are highlighted. The approach taken in the SHARP system to overcome the current limitations is also described, as well as both the conventional and artificial intelligence solutions developed in SHARP.

  2. SHARP: A multi-mission AI system for spacecraft telemetry monitoring and diagnosis

    NASA Technical Reports Server (NTRS)

    Lawson, Denise L.; James, Mark L.

    1989-01-01

    The Spacecraft Health Automated Reasoning Prototype (SHARP) is a system designed to demonstrate automated health and status analysis for multi-mission spacecraft and ground data systems operations. Telecommunications link analysis of the Voyager II spacecraft is the initial focus for the SHARP system demonstration which will occur during Voyager's encounter with the planet Neptune in August, 1989, in parallel with real-time Voyager operations. The SHARP system combines conventional computer science methodologies with artificial intelligence techniques to produce an effective method for detecting and analyzing potential spacecraft and ground systems problems. The system performs real-time analysis of spacecraft and other related telemetry, and is also capable of examining data in historical context. A brief introduction is given to the spacecraft and ground systems monitoring process at the Jet Propulsion Laboratory. The current method of operation for monitoring the Voyager Telecommunications subsystem is described, and the difficulties associated with the existing technology are highlighted. The approach taken in the SHARP system to overcome the current limitations is also described, as well as both the conventional and artificial intelligence solutions developed in SHARP.

  3. Design of Test Articles and Monitoring System for the Characterization of HIRF Effects on a Fault-Tolerant Computer Communication System

    NASA Technical Reports Server (NTRS)

    Torres-Pomales, Wilfredo; Malekpour, Mahyar R.; Miner, Paul S.; Koppen, Sandra V.

    2008-01-01

    This report describes the design of the test articles and monitoring systems developed to characterize the response of a fault-tolerant computer communication system when stressed beyond the theoretical limits for guaranteed correct performance. A high-intensity radiated electromagnetic field (HIRF) environment was selected as the means of injecting faults, as such environments are known to have the potential to cause arbitrary and coincident common-mode fault manifestations that can overwhelm redundancy management mechanisms. The monitors generate stimuli for the systems-under-test (SUTs) and collect data in real-time on the internal state and the response at the external interfaces. A real-time health assessment capability was developed to support the automation of the test. A detailed description of the nature and structure of the collected data is included. The goal of the report is to provide insight into the design and operation of these systems, and to serve as a reference document for use in post-test analyses.

  4. Clinical Use of Continuous Glucose Monitoring in Adults with Type 1 Diabetes.

    PubMed

    Slattery, David; Choudhary, Pratik

    2017-05-01

    With the emphasis on intensive management of type 1 diabetes, data from studies support frequent monitoring of glucose levels to improve glycemic control and reduce glucose variability, which can be related to an increase in macro and microvascular complications. However, few perform capillary blood glucose that frequently. There are currently two available alternatives that this review will discuss, continuous glucose monitoring (CGM) and flash glucose monitoring. CGM has become an important diagnostic and therapeutic option in optimizing diabetes management. CGM systems are now more accurate, smaller, and easier to use compared to original models. Randomized controlled trials (RCTs) have demonstrated that CGM can improve Hemoglobin A1c (HbA1C) and reduce glucose variability in both continuous subcutaneous insulin infusion and multiple daily injection users. When used in an automated "insulin-suspend" system, reduced frequency of hypoglycemia and shorter time spent in hypoglycemic range have been demonstrated. Despite the potential benefits CGM has to offer in clinical practice, concerns exist on the accuracy of these devices and patient compliance with therapy, which may prevent the true clinical benefit of CGM being achieved, as observed in RCTs. Flash glucose monitoring systems FreeStyle ® Libre™ (Abbott Diabetes Care, Alameda, CA) are as accurate as many CGM systems available and have the added benefit of being factory calibrated. Studies have shown that flash glucose monitoring systems are very well tolerated by patients and effectively reduce glucose variability, increasing time in range.

  5. A proposed coast-wide reference monitoring system for evaluating Wetland restoration trajectories in Louisiana

    USGS Publications Warehouse

    Steyer, G.D.; Sasser, C.E.; Visser, J.M.; Swenson, E.M.; Nyman, J.A.; Raynie, R.C.

    2003-01-01

    Wetland restoration efforts conducted in Louisiana under the Coastal Wetlands Planning, Protection and Restoration Act require monitoring the effectiveness of individual projects as well as monitoring the cumulative effects of all projects in restoring, creating, enhancing, and protecting the coastal landscape. The effectiveness of the traditional paired-reference monitoring approach in Louisiana has been limited because of difficulty in finding comparable reference sites. A multiple reference approach is proposed that uses aspects of hydrogeomorphic functional assessments and probabilistic sampling. This approach includes a suite of sites that encompass the range of ecological condition for each stratum, with projects placed on a continuum of conditions found for that stratum. Trajectories in reference sites through time are then compared with project trajectories through time. Plant community zonation complicated selection of indicators, strata, and sample size. The approach proposed could serve as a model for evaluating wetland ecosystems.

  6. A proposed coast-wide reference monitoring system for evaluating wetland restoration trajectories in Louisiana.

    PubMed

    Steyer, Gregory D; Sasser, Charles E; Visser, Jenneke M; Swenson, Erick M; Nyman, John A; Raynie, Richard C

    2003-01-01

    Wetland restoration efforts conducted in Louisiana under the Coastal Wetlands Planning, Protection and Restoration Act require monitoring the effectiveness of individual projects as well as monitoring the cumulative effects of all projects in restoring, creating, enhancing, and protecting the coastal landscape. The effectiveness of the traditional paired-reference monitoring approach in Louisiana has been limited because of difficulty in finding comparable reference sites. A multiple reference approach is proposed that uses aspects of hydrogeomorphic functional assessments and probabilistic sampling. This approach includes a suite of sites that encompass the range of ecological condition for each stratum, with projects placed on a continuum of conditions found for that stratum. Trajectories in reference sites through time are then compared with project trajectories through time. Plant community zonation complicated selection of indicators, strata, and sample size. The approach proposed could serve as a model for evaluating wetland ecosystems.

  7. Design and development of a highly sensitive, field portable plasma source instrument for on-line liquid stream monitoring and real-time sample analysis

    NASA Astrophysics Data System (ADS)

    Duan, Yixiang; Su, Yongxuan; Jin, Zhe; Abeln, Stephen P.

    2000-03-01

    The development of a highly sensitive, field portable, low-powered instrument for on-site, real-time liquid waste stream monitoring is described in this article. A series of factors such as system sensitivity and portability, plasma source, sample introduction, desolvation system, power supply, and the instrument configuration, were carefully considered in the design of the portable instrument. A newly designed, miniature, modified microwave plasma source was selected as the emission source for spectroscopy measurement, and an integrated small spectrometer with a charge-coupled device detector was installed for signal processing and detection. An innovative beam collection system with optical fibers was designed and used for emission signal collection. Microwave plasma can be sustained with various gases at relatively low power, and it possesses high detection capabilities for both metal and nonmetal pollutants, making it desirable to use for on-site, real-time, liquid waste stream monitoring. An effective in situ sampling system was coupled with a high efficiency desolvation device for direct-sampling liquid samples into the plasma. A portable computer control system is used for data processing. The new, integrated instrument can be easily used for on-site, real-time monitoring in the field. The system possesses a series of advantages, including high sensitivity for metal and nonmetal elements; in situ sampling; compact structure; low cost; and ease of operation and handling. These advantages will significantly overcome the limitations of previous monitoring techniques and make great contributions to environmental restoration and monitoring.

  8. Remote monitoring of patients with implanted devices: data exchange and integration.

    PubMed

    Van der Velde, Enno T; Atsma, Douwe E; Foeken, Hylke; Witteman, Tom A; Hoekstra, Wybo H G J

    2013-06-01

    Remote follow-up of implanted implantable cardioverter defibrillators (ICDs) may offer a solution to the problem of overcrowded outpatient clinics, and may also be effective in detecting clinical events early. Data obtained from remote follow up systems, as developed by all major device companies, are stored in a central database system, operated and owned by the device company. A problem now arises that the patient's clinical information is partly stored in the local electronic health record (EHR) system in the hospital, and partly in the remote monitoring database, which may potentially result in patient safety issues. To address the requirement of integrating remote monitoring data in the local EHR, the Integrating the Healthcare Enterprise (IHE) Implantable Device Cardiac Observation (IDCO) profile has been developed. This IHE IDCO profile has been adapted by all major device companies. In our hospital, we have implemented the IHE IDCO profile to import data from the remote databases from two device vendors into the departmental Cardiology Information System (EPD-Vision). Data is exchanged via a HL7/XML communication protocol, as defined in the IHE IDCO profile. By implementing the IHE IDCO profile, we have been able to integrate the data from the remote monitoring databases in our local EHRs. It can be expected that remote monitoring systems will develop into dedicated monitoring and therapy platforms. Data retrieved from these systems should form an integral part of the electronic patient record as more and more out-patient clinic care will shift to personalized care provided at a distance, in other words at the patient's home.

  9. Evaluation of low-cost computer monitors for the detection of cervical spine injuries in the emergency room: an observer confidence-based study.

    PubMed

    Brem, M H; Böhner, C; Brenning, A; Gelse, K; Radkow, T; Blanke, M; Schlechtweg, P M; Neumann, G; Wu, I Y; Bautz, W; Hennig, F F; Richter, H

    2006-11-01

    To compare the diagnostic value of low-cost computer monitors and a Picture Archiving and Communication System (PACS) workstation for the evaluation of cervical spine fractures in the emergency room. Two groups of readers blinded to the diagnoses (2 radiologists and 3 orthopaedic surgeons) independently assessed-digital radiographs of the cervical spine (anterior-posterior, oblique and trans-oral-dens views). The radiographs of 57 patients who arrived consecutively to the emergency room in 2004 with clinical suspicion of a cervical spine injury were evaluated. The diagnostic values of these radiographs were scored on a 3-point scale (1 = diagnosis not possible/bad image quality, 2 = diagnosis uncertain, 3 = clear diagnosis of fracture or no fracture) on a PACS workstation and on two different liquid crystal display (LCD) personal computer monitors. The images were randomised to avoid memory effects. We used logistic mixed-effects models to determine the possible effects of monitor type on the evaluation of x ray images. To determine the overall effects of monitor type, this variable was used as a fixed effect, and the image number and reader group (radiologist or orthopaedic surgeon) were used as random effects on display quality. Group-specific effects were examined, with the reader group and additional fixed effects as terms. A significance level of 0.05 was established for assessing the contribution of each fixed effect to the model. Overall, the diagnostic score did not differ significantly between standard personal computer monitors and the PACS workstation (both p values were 0.78). Low-cost LCD personal computer monitors may be useful in establishing a diagnosis of cervical spine fractures in the emergency room.

  10. FAULT PROPAGATION AND EFFECTS ANALYSIS FOR DESIGNING AN ONLINE MONITORING SYSTEM FOR THE SECONDARY LOOP OF A NUCLEAR POWER PLANT PART OF A HYBRID ENERGY SYSTEM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Li, Huijuan; Diao, Xiaoxu; Li, Boyuan

    This paper studies the propagation and effects of faults of critical components that pertain to the secondary loop of a nuclear power plant found in Nuclear Hybrid Energy Systems (NHES). This information is used to design an on-line monitoring (OLM) system which is capable of detecting and forecasting faults that are likely to occur during NHES operation. In this research, the causes, features, and effects of possible faults are investigated by simulating the propagation of faults in the secondary loop. The simulation is accomplished by using the Integrated System Failure Analysis (ISFA). ISFA is used for analyzing hardware and softwaremore » faults during the conceptual design phase. In this paper, the models of system components required by ISFA are initially constructed. Then, the fault propagation analysis is implemented, which is conducted under the bounds set by acceptance criteria derived from the design of an OLM system. The result of the fault simulation is utilized to build a database for fault detection and diagnosis, provide preventive measures, and propose an optimization plan for the OLM system.« less

  11. 23 CFR 500.108 - SMS.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Management Systems: Good Practices for Development and Implementation.” 3 An effective SMS should include, at... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT MANAGEMENT AND MONITORING SYSTEMS Management Systems § 500.108 SMS. An SMS is a systematic process with the goal of reducing the...

  12. 23 CFR 500.108 - SMS.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Management Systems: Good Practices for Development and Implementation.” 3 An effective SMS should include, at... ADMINISTRATION, DEPARTMENT OF TRANSPORTATION TRANSPORTATION INFRASTRUCTURE MANAGEMENT MANAGEMENT AND MONITORING SYSTEMS Management Systems § 500.108 SMS. An SMS is a systematic process with the goal of reducing the...

  13. 40 CFR 191.12 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...

  14. 40 CFR 191.12 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...

  15. 40 CFR 191.12 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... metric system which has been established by the International Bureau of Weights and Measures and is...) monitoring parameters related to disposal system performance. Annual committed effective dose means the... radioactive wastes in a disposal system; and (2) the subsurface underlying such a surface location. Disposal...

  16. Camera positioning and calibration techniques for integrating traffic surveillance video systems with machine-vision vehicle detection devices.

    DOT National Transportation Integrated Search

    2002-12-01

    The Virginia Department of Transportation, like many other transportation agencies, has invested significantly in extensive closed circuit television (CCTV) systems to monitor freeways in urban areas. Although these systems have proven very effective...

  17. Mobile devices for community-based REDD+ monitoring: a case study for Central Vietnam.

    PubMed

    Pratihast, Arun Kumar; Herold, Martin; Avitabile, Valerio; de Bruin, Sytze; Bartholomeus, Harm; Souza, Carlos M; Ribbe, Lars

    2012-12-20

    Monitoring tropical deforestation and forest degradation is one of the central elements for the Reduced Emissions from Deforestation and Forest Degradation in developing countries (REDD+) scheme. Current arrangements for monitoring are based on remote sensing and field measurements. Since monitoring is the periodic process of assessing forest stands properties with respect to reference data, adopting the current REDD+ requirements for implementing monitoring at national levels is a challenging task. Recently, the advancement in Information and Communications Technologies (ICT) and mobile devices has enabled local communities to monitor their forest in a basic resource setting such as no or slow internet connection link, limited power supply, etc. Despite the potential, the use of mobile device system for community based monitoring (CBM) is still exceptional and faces implementation challenges. This paper presents an integrated data collection system based on mobile devices that streamlines the community-based forest monitoring data collection, transmission and visualization process. This paper also assesses the accuracy and reliability of CBM data and proposes a way to fit them into national REDD+ Monitoring, Reporting and Verification (MRV) scheme. The system performance is evaluated at Tra Bui commune, Quang Nam province, Central Vietnam, where forest carbon and change activities were tracked. The results show that the local community is able to provide data with accuracy comparable to expert measurements (index of agreement greater than 0.88), but against lower costs. Furthermore, the results confirm that communities are more effective to monitor small scale forest degradation due to subsistence fuel wood collection and selective logging, than high resolution remote sensing SPOT imagery.

  18. Mobile Devices for Community-Based REDD+ Monitoring: A Case Study for Central Vietnam

    PubMed Central

    Pratihast, Arun Kumar; Herold, Martin; Avitabile, Valerio; de Bruin, Sytze; Bartholomeus, Harm; Souza, Carlos M.; Ribbe, Lars

    2013-01-01

    Monitoring tropical deforestation and forest degradation is one of the central elements for the Reduced Emissions from Deforestation and Forest Degradation in developing countries (REDD+) scheme. Current arrangements for monitoring are based on remote sensing and field measurements. Since monitoring is the periodic process of assessing forest stands properties with respect to reference data, adopting the current REDD+ requirements for implementing monitoring at national levels is a challenging task. Recently, the advancement in Information and Communications Technologies (ICT) and mobile devices has enabled local communities to monitor their forest in a basic resource setting such as no or slow internet connection link, limited power supply, etc. Despite the potential, the use of mobile device system for community based monitoring (CBM) is still exceptional and faces implementation challenges. This paper presents an integrated data collection system based on mobile devices that streamlines the community-based forest monitoring data collection, transmission and visualization process. This paper also assesses the accuracy and reliability of CBM data and proposes a way to fit them into national REDD+ Monitoring, Reporting and Verification (MRV) scheme. The system performance is evaluated at Tra Bui commune, Quang Nam province, Central Vietnam, where forest carbon and change activities were tracked. The results show that the local community is able to provide data with accuracy comparable to expert measurements (index of agreement greater than 0.88), but against lower costs. Furthermore, the results confirm that communities are more effective to monitor small scale forest degradation due to subsistence fuel wood collection and selective logging, than high resolution remote sensing SPOT imagery. PMID:23344371

  19. Data Fusion Tool for Spiral Bevel Gear Condition Indicator Data

    NASA Technical Reports Server (NTRS)

    Dempsey, Paula J.; Antolick, Lance J.; Branning, Jeremy S.; Thomas, Josiah

    2014-01-01

    Tests were performed on two spiral bevel gear sets in the NASA Glenn Spiral Bevel Gear Fatigue Test Rig to simulate the fielded failures of spiral bevel gears installed in a helicopter. Gear sets were tested until damage initiated and progressed on two or more gear or pinion teeth. During testing, gear health monitoring data was collected with two different health monitoring systems. Operational parameters were measured with a third data acquisition system. Tooth damage progression was documented with photographs taken at inspection intervals throughout the test. A software tool was developed for fusing the operational data and the vibration based gear condition indicator (CI) data collected from the two health monitoring systems. Results of this study illustrate the benefits of combining the data from all three systems to indicate progression of damage for spiral bevel gears. The tool also enabled evaluation of the effectiveness of each CI with respect to operational conditions and fault mode.

  20. IMPEDANCE ALARM SYSTEM

    DOEpatents

    Cowen, R.G.

    1959-09-29

    A description is given of electric protective systems and burglar alarm systems of the capacitance type in which the approach of an intruder at a place to be protected varies the capacitance in an electric circuit and the change is thereafter communicated to a remote point to actuate an alarm. According to the invention, an astable transitor multi-vibrator has the amplitude at its output voltage controlled by a change in the sensing capacitance. The sensing capacitance is effectively connected between collector and base of one stage of the multivibrator circuit through the detector-to-monitor line. The output of the detector is a small d-c voltage across the detector-to-monitor line. This d- c voltage is amplified and monitored at the other end of the line, where an appropriate alarm is actuated if a sudden change in the voltage occurs. The present system has a high degree of sensitivity and is very difficult to defeat by known techniques.

  1. Structural health monitoring and probability of detection estimation

    NASA Astrophysics Data System (ADS)

    Forsyth, David S.

    2016-02-01

    Structural health monitoring (SHM) methods are often based on nondestructive testing (NDT) sensors and are often proposed as replacements for NDT to lower cost and/or improve reliability. In order to take advantage of SHM for life cycle management, it is necessary to determine the Probability of Detection (POD) of the SHM system just as for traditional NDT to ensure that the required level of safety is maintained. Many different possibilities exist for SHM systems, but one of the attractive features of SHM versus NDT is the ability to take measurements very simply after the SHM system is installed. Using a simple statistical model of POD, some authors have proposed that very high rates of SHM system data sampling can result in high effective POD even in situations where an individual test has low POD. In this paper, we discuss the theoretical basis for determining the effect of repeated inspections, and examine data from SHM experiments against this framework to show how the effective POD from multiple tests can be estimated.

  2. How to develop a proactive formulary system.

    PubMed

    Crane, V S; Gonzalez, E R; Hull, B L

    1994-10-01

    To develop a quality formulary system, a proactive approach is necessary. This approach incorporates a prospective product and concurrent product analyses. A prospective product analysis, in turn, involves a review of current formulary agents, those likely to enter the marketplace shortly, and the formation of an expert review panel. This panel's tasks are to examine therapeutic, economic, and humanistic aspects of therapy and to set initial parameters for appropriate and cost-effective use of accepted products. Keys to a successful formulary system are to continuously monitor drug use and compliance with criteria and to work collaboratively with all institutional professionals in the development, implementation, and monitoring of the system.

  3. IBRD sonar scour monitoring project : real-time river channel-bed monitoring at the Chariton and Mississippi Rivers in Missouri, 2007-09, final report, January 2010.

    DOT National Transportation Integrated Search

    2010-01-01

    Scour and depositional responses to hydrologic events have been important to the scientific community studying sediment transport as well as potential effects on bridges and other hydraulic structures within riverine systems. A river channel-bed moni...

  4. SMART Security Cooperation Objectives: Improving DoD Planning and Guidance

    DTIC Science & Technology

    2016-01-01

    integrate them into a system for assessing, monitoring, and evaluating security cooperation programs and activities. This report evaluates DoD’s...effectiveness in developing SMART security coopera- tion objectives that facilitate assessment, monitoring, and evaluation . It also proposes a systematic...Cooperation Ends, Ways, and Means . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 RAND Evaluation and Revision of Selected

  5. 78 FR 73577 - Self-Regulatory Organizations; BATS Exchange, Inc.; Notice of Filing and Immediate Effectiveness...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-06

    ...)(ii). Overview Currently, the Exchange's Risk Monitor Mechanism operates by the System maintaining a... Makers and other Users with greater control and flexibility with respect to managing risk and the manner...'', in order to modify the risk monitoring functionality offered to all Users \\5\\ of the BATS equity...

  6. Intervention in Deficient School Districts: Re-Establishing Effective Local Control.

    ERIC Educational Resources Information Center

    Cooperman, Saul

    In the wake of January 1988 takeover legislation to improve education in the State of New Jersey, this paper describes and justifies the strict state three-tier monitoring system of school district educational standards. School districts that need improvement after the first level of monitoring must develop an improvement plan to overcome their…

  7. Ultrasound monitoring of inter-knee distances during gait.

    PubMed

    Lai, Daniel T H; Wrigley, Tim V; Palaniswami, M

    2009-01-01

    Knee osteoarthritis is an extremely common, debilitating disease associated with pain and loss of function. There is considerable interest in monitoring lower limb alignment due to its close association with joint overload leading to disease progression. The effects of gait modifications that can lower joint loading are of particular interest. Here we describe an ultrasound-based system for monitoring an important aspect of dynamic lower limb alignment, the inter-knee distance during walking. Monitoring this gait parameter should facilitate studies in reducing knee loading, a primary risk factor of knee osteoarthritis progression. The portable device is composed of an ultrasound sensor connected to an Intel iMote2 equipped with Bluetooth wireless capability. Static tests and calibration results show that the sensor possesses an effective beam envelope of 120 degrees, with maximum distance errors of 10% at the envelope edges. Dynamic walking trials reveal close correlation of inter-knee distance trends between that measured by an optical system (Optotrak Certus NDI) and the sensor device. The maximum average root mean square error was found to be 1.46 cm. Future work will focus on improving the accuracy of the device.

  8. Monitoring of diesel engine combustions based on the acoustic source characterisation of the exhaust system

    NASA Astrophysics Data System (ADS)

    Jiang, J.; Gu, F.; Gennish, R.; Moore, D. J.; Harris, G.; Ball, A. D.

    2008-08-01

    Acoustic methods are among the most useful techniques for monitoring the condition of machines. However, the influence of background noise is a major issue in implementing this method. This paper introduces an effective monitoring approach to diesel engine combustion based on acoustic one-port source theory and exhaust acoustic measurements. It has been found that the strength, in terms of pressure, of the engine acoustic source is able to provide a more accurate representation of the engine combustion because it is obtained by minimising the reflection effects in the exhaust system. A multi-load acoustic method was then developed to determine the pressure signal when a four-cylinder diesel engine was tested with faults in the fuel injector and exhaust valve. From the experimental results, it is shown that a two-load acoustic method is sufficient to permit the detection and diagnosis of abnormalities in the pressure signal, caused by the faults. This then provides a novel and yet reliable method to achieve condition monitoring of diesel engines even if they operate in high noise environments such as standby power stations and vessel chambers.

  9. Development and Application of a ZigBee-Based Building Energy Monitoring and Control System

    PubMed Central

    Peng, Changhai

    2014-01-01

    Increasing in energy consumption, particularly with the ever-increasing growth and development of urban systems, has become a major concern in most countries. In this paper, the authors propose a cost-effective ZigBee-based building energy monitoring and control system (ZBEMCS), which is composed of a gateway, a base station, and sensors. Specifically, a new hardware platform for power sensor nodes is developed to perform both local/remote power parameter measurement and power on/off switching for electric appliances. The experimental results show that the ZBEMCS can easily monitor energy usage with a high level of accuracy. Two typical applications of ZBEMCS such as subentry metering and household metering of building energy are presented. The former includes lighting socket electricity, HVAC electricity, power electricity and special electricity. The latter includes household metering according to the campus's main function zone and each college or department. Therefore, this system can be used for energy consumption monitoring, long-term energy conservation planning, and the development of automated energy conservation for building applications. PMID:25254249

  10. Development and application of a ZigBee-based building energy monitoring and control system.

    PubMed

    Peng, Changhai; Qian, Kun

    2014-01-01

    Increasing in energy consumption, particularly with the ever-increasing growth and development of urban systems, has become a major concern in most countries. In this paper, the authors propose a cost-effective ZigBee-based building energy monitoring and control system (ZBEMCS), which is composed of a gateway, a base station, and sensors. Specifically, a new hardware platform for power sensor nodes is developed to perform both local/remote power parameter measurement and power on/off switching for electric appliances. The experimental results show that the ZBEMCS can easily monitor energy usage with a high level of accuracy. Two typical applications of ZBEMCS such as subentry metering and household metering of building energy are presented. The former includes lighting socket electricity, HVAC electricity, power electricity and special electricity. The latter includes household metering according to the campus's main function zone and each college or department. Therefore, this system can be used for energy consumption monitoring, long-term energy conservation planning, and the development of automated energy conservation for building applications.

  11. Statistical analysis of long-term hydrologic records for selection of drought-monitoring sites on Long Island, New York

    USGS Publications Warehouse

    Busciolano, Ronald J.

    2005-01-01

    Ground water is the sole source of water supply for more than 3 million people on Long Island, New York. Large-scale ground-water pumpage, sewering systems, and prolonged periods of below-normal precipitation have lowered ground-water levels and decreased stream-discharge in western and central Long Island. No method is currently (2004) available on Long Island that can assess data from the ground-water-monitoring network to enable water managers and suppliers with the ability to give timely warning of severe water-level declines.This report (1) quantifies past drought- and human-induced changes in the ground-water system underlying Long Island by applying statistical and graphical methods to precipitation, stream-discharge, and ground-water-level data from selected monitoring sites; (2) evaluates the relation between water levels in the upper glacial aquifer and those in the underlying Magothy aquifer; (3) defines trends in stream discharge and ground-water levels that might indicate the onset of drought conditions or the effects of excessive pumping; and (4) discusses the long-term records that were used to select sites for a Long Island drought-monitoring network.Long Island’s long-term hydrologic records indicated that the available data provide a basis for development of a drought-monitoring network. The data from 36 stations that were selected as possible drought-monitoring sites—8 precipitation-monitoring stations, 8 streamflow-gaging (discharge) stations, 15 monitoring wells screened in the upper glacial aquifer under water-table (unconfined) conditions, and 5 monitoring wells screened in the underlying Magothy aquifer under semi-confined conditions—indicate that water levels in western parts of Long Island have fallen and risen markedly (more than 15 ft) in response to fluctuations in pumpage, and have declined from the increased use of sanitary- and storm-sewer systems. Water levels in the central and eastern parts, in contrast, remain relatively unaffected compared to the western parts, although the effects of human activity are discernible in the records.The value of each site as a drought-monitoring indicator was assessed through an analysis of trends in the records. Fifty-year annual and monthly data sets were created and combined into three composite-average hydrographs—precipitation, stream discharge, and ground-water levels. Three zones representing the range of human effect on ground-water levels were delineated to help evaluate islandwide hydrologic conditions and to quantify the indices. Data from the three indices can be used to assess current conditions in the ground-water system underlying Long Island and evaluate water-level declines during periods of drought.

  12. Characteristics Study of In-Situ Capacitive Sensor for Monitoring Lubrication Oil Debris

    PubMed Central

    Han, Zhibin; Wang, Yishou; Qing, Xinlin

    2017-01-01

    As an essential part of engine health monitoring (EHM), online lubrication oil debris monitoring has recently received great attention for the assessment of rotating and reciprocating parts in aero-engines, due to its high integration, low cost and safe characteristics. However, it is be a challenge to find a suitable sensor operating in such a complex environment. We present an unconventional novel approach, in which a cylinder capacitive sensor is designed and integrated with the pipeline of an engine lubrication system, so that the capacitive sensor can effectively detect changes in the lubrication oil condition. In this paper, an attempt to illustrate the performance characteristics of the developed cylinder capacitive sensor is made, through an experiment system that simulates a real scenario of a lubrication oil system. The main aim of the research was to qualitatively describe the relationship between the sensor parameter and the lubrication oil debris. In addition, the effect of the temperature and flow rate of the lubrication oil on capacitance change was performed by several experiments and we figured out a compensation method. The experimental results demonstrated that the cylinder capacitive sensor can potentially be used for lubrication oil debris monitoring of the health condition of an aero-engine. PMID:29292748

  13. Statistical Analysis of Stress Signals from Bridge Monitoring by FBG System.

    PubMed

    Ye, Xiao-Wei; Su, You-Hua; Xi, Pei-Sen

    2018-02-07

    In this paper, a fiber Bragg grating (FBG)-based stress monitoring system instrumented on an orthotropic steel deck arch bridge is demonstrated. The FBG sensors are installed at two types of critical fatigue-prone welded joints to measure the strain and temperature signals. A total of 64 FBG sensors are deployed around the rib-to-deck and rib-to-diagram areas at the mid-span and quarter-span of the investigated orthotropic steel bridge. The local stress behaviors caused by the highway loading and temperature effect during the construction and operation periods are presented with the aid of a wavelet multi-resolution analysis approach. In addition, the multi-modal characteristic of the rainflow counted stress spectrum is modeled by the method of finite mixture distribution together with a genetic algorithm (GA)-based parameter estimation approach. The optimal probability distribution of the stress spectrum is determined by use of Bayesian information criterion (BIC). Furthermore, the hot spot stress of the welded joint is calculated by an extrapolation method recommended in the specification of International Institute of Welding (IIW). The stochastic characteristic of stress concentration factor (SCF) of the concerned welded joint is addressed. The proposed FBG-based stress monitoring system and probabilistic stress evaluation methods can provide an effective tool for structural monitoring and condition assessment of orthotropic steel bridges.

  14. [Nephro-urological monitoring technology based on radionuclide functional tests (tasks of an automated workplace)].

    PubMed

    Averinova, S G; Kashkadaeva, A V; Shiriaev, S V; Nechipaĭ, A M; Dmitrieva, G D

    1999-01-01

    The paper deals with a diagnostic informational and analytical system (DIAS). The system is based on the current concept of a dynamic model of nephro-urological clearance macroregulation under retention factors at the pre-, intra-, and postrenal levels during drug load tests. DIAS includes a package of dynamic renoscintigraphic techniques, as well as original software support. A system for parameters of renal clearance regulation has been developed, which is effective at nephro-urological screening and monitoring at all treatment stages for cancer patients. A two-detector chamber which permits the mounting of a detector at an angle to the patient's body is the optimum diagnostic apparatus for a cancer clinic. The use of functional tests makes it possible to examine the regulatory reserves for each kidney, followed up by the choice of adequate corrective measures to prevent renal failure during treatment. In some cases, DIAS monitoring frequently shows a higher sensitivity to the signs of latent renal failure than does routine clinical and laboratory monitoring. The effective radiation dose taken by a patient during a study by the DIAS technology aimed at reducing radioopaque doses is 100-150 times higher than that at an X-ray study and is an order less than during routine urinary tests.

  15. Fluvial particle characterization using artificial neural network and spectral image processing

    NASA Astrophysics Data System (ADS)

    Shrestha, Bim Prasad; Gautam, Bijaya; Nagata, Masateru

    2008-03-01

    Sand, chemical waste, microbes and other solid materials flowing with the water bodies are of great significance to us as they cause substantial impact to different sectors including drinking water management, hydropower generation, irrigation, aquatic life preservation and various other socio-ecological factors. Such particles can't completely be avoided due to the high cost of construction and maintenance of the waste-treatment methods. A detailed understanding of solid particles in surface water system can have benefit in effective, economic, environmental and social management of water resources. This paper describes an automated system of fluvial particle characterization based on spectral image processing that lead to the development of devices for monitoring flowing particles in river. Previous research in coherent field has shown that it is possible to automatically classify shapes and sizes of solid particles ranging from 300-400 μm using artificial neural networks (ANN) and image processing. Computer facilitated with hyper spectral and multi spectral images using ANN can further classify fluvial materials into organic, inorganic, biodegradable, bio non degradable and microbes. This makes the method attractive for real time monitoring of particles, sand and microorganism in water bodies at strategic locations. Continuous monitoring can be used to determine the effect of socio-economic activities in upstream rivers, or to monitor solid waste disposal from treatment plants and industries or to monitor erosive characteristic of sand and its contribution to degradation of efficiency of hydropower plant or to identify microorganism, calculate their population and study the impact of their presence. Such system can also be used to characterize fluvial particles for planning effective utilization of water resources in micro-mega hydropower plant, irrigation, aquatic life preservation etc.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Costa, Mafalda T., E-mail: mafaldatcosta@gmail.com; Carolino, Elisabete, E-mail: lizcarolino@gmail.com; Oliveira, Teresa A., E-mail: teresa.oliveira@uab.pt

    In water supply systems with distribution networkthe most critical aspects of control and Monitoring of water quality, which generates crises system, are the effects of cross-contamination originated by the network typology. The classics of control of quality systems through the application of Shewhart charts are generally difficult to manage in real time due to the high number of charts that must be completed and evaluated. As an alternative to the traditional control systems with Shewhart charts, this study aimed to apply a simplified methodology of a monitoring plan quality parameters in a drinking water distribution, by applying Hotelling’s T{sup 2}more » charts and supplemented with Shewhart charts with Bonferroni limits system, whenever instabilities with processes were detected.« less

  17. Olympus propagation studies in the US: Receiver development and the data acquisition system

    NASA Technical Reports Server (NTRS)

    Mckeeman, John C.

    1990-01-01

    Virginia Tech has developed two types of receivers to monitor the Olympus beacons, as well as a custom data acquisition system to store and display propagation data. Each of the receiver designs uses new hybrid analog/digital techniques. The data acquisition system uses a stand alone processor to collect and format the data for display and subsequent processing. The launch of the Olympus satellite with its coherent beacons offers new opportunities to study propagation effects at 12.5, 20, and 30 GHz. At Virginia Tech, the satellite is at 14 degrees in elevation, which allows us to measure low elevation angle effects. However, to make these measurements, a very accurate and stable measurement system is required. Virginia Tech has constructed a complex receiving system which monitors the Olympus beacons and all parameters associated with propagation research. In the current configuration, researchers have developed a receiver which frequency locks to the less fade susceptible 12.5 GHz beacon. Since all beacons on the satellite are driven from a single master oscillator, drift in the 12.5 GHz beacon implies corresponding drifts in the 20, and 30 GHz beacons. The receivers for the 20 and 30 GHz systems derive their frequency locking information from the 12.5 GHz system. This widens the dynamic range of the receivers and allows the receivers to maintain lock in severe fade conditions. In addition to monitoring the beacons, the sky noise is monitored with radiometers at each frequency. The radiometer output is used to set the clear air level for each beacon measurement. Researchers also measure the rain rate with several tipping bucket rain gauges placed along the propagation path.

  18. Wireless health monitoring of cracks in structures with MEMS-IDT sensors

    NASA Astrophysics Data System (ADS)

    Kim, Jae-Sung; Vinoy, K. J.; Varadan, Vijay K.

    2002-07-01

    The integration of MEMS, IDTs and required microelectronics and conformal antennas to realize programmable, robust and low cost passive microsensors suitable for many military structures and systems including aircraft, missiles and munitions is presented in this paper. The technology is currently being applied to the structural health monitoring of accelerometers, gyroscopes and vibration monitoring devices with signal processing electronics to provide real- time indicators of incipient failure of aircraft components with a known history of catastrophic failure due to fracture. Recently a combination of the need for safety in the air and the desire to control costs is encouraging the use of in-flight monitoring of aircraft components and systems using light-weight, wireless and cost effective microsensors and MEMS. An in-situ Aircraft structural health monitoring system, with sensors embedded in the composite structure or surface-mounted on the structure, would permit the timely detection of damage in aircraft. Micromachining offers the potential for fabricating a range of microsensors and MEMS for structural applications including load, vibration and acoustics characteristics and monitoring. Such microsensors are extremely small; they can be embedded into structural materials, can be mass-produced and are therefore potentially cheap. Additionally a range of sensor types can be integrated onto a single chip with built-in electronics and ASIC, providing a low power microsystem. The smart sensors are being developed using the standard microelectronics and micromachining in conjunction with novel Penn State smart electronics or wireless communication systems suitable for condition monitoring of aircraft structures in-flight. A hybrid accelerometer and gyroscope in a single chip suitable for inertial navigation system and other microsensors for health monitoring and condition-based maintenance of structures, drag sensing and control of aircraft, strain and deflection of structures and systems, ice sensing on aircraft, remote temperature and humidity measurement of propellant in munitions, chemical sensing, etc. are discussed.

  19. Wireless microsensors for health monitoring of aircraft structures

    NASA Astrophysics Data System (ADS)

    Varadan, Vijay K.

    2003-01-01

    The integration of MEMS, IDTs (interdigital transducers) and required microelectronics and conformal antennas to realize programmable, robust and low cost passive microsensors suitable for many military structures and systems including aircraft, missiles and munitions is presented in this paper. The technology is currently being applied to the structural health monitoring of critical aircraft components. The approach integrates acoustic emission, strain gauges, MEMS accelerometers, gyroscopes and vibration monitoring devices with signal processing electronics to provide real-time indicators of incipient failure of aircraft components with a known history of catastrophic failure due to fracture. Recently a combination of the need for safety in the air and the desire to control costs is encouraging the use of in-flight monitoring of aircraft components and systems using light-weight, wireless and cost effective microsensors and MEMS. An in-situ Aircraft structural health monitoring (ASHM) system, with sensors embedded in the composite structure or surface-mounted on the structure, would permit the timely detection of damage in aircraft. Micromachining offers the potential for fabricating a range of microsensors and MEMS for structural applications including load, vibration and acoustics characterization and monitoring. Such microsensors are extremely small; they can be embedded into structural materials, can be mass-produced and are therefore potentially cheap. Additionally a range of sensor types can be integrated onto a single chip with built-in electronics and ASIC (Application Specific Integrated Circuit), providing a low power Microsystems. The smart sensors are being developed using the standard microelectronics and micromachining in conjunction with novel Penn State smart electronics or wireless communication systems suitable for condition monitoring of aircraft structures in-flight. A hybrid accelerometer and gyroscope in a single chip suitable for inertial navigation system and other microsensors for health monitoring and condition-based maintenance of structures, drag sensing and control of aircraft, strain and deflection of structures and systems, ice sensing on aircraft, remote temperature and humidity measurement of propellant in munitions, chemical sensing, etc. are discussed.

  20. Public Perceptions of GPS Monitoring for Convicted Sex Offenders: Opinions on Effectiveness of Electronic Monitoring to Reduce Sexual Recidivism.

    PubMed

    Budd, Kristen M; Mancini, Christina

    2017-09-01

    In the United States, electronic monitoring (EM) and global positioning systems (GPS) are new applications that are used to extensively monitor and track convicted sex offenders. What is unclear though are public perceptions of this strategy. This research examines public perceptions of a national sample of Americans on the use of GPS/EM with convicted sex offenders as a method to reduce their sexual recidivism. Using a multinomial regression model, we analyze the effects of sex offender myths and parental status on public perceptions that sex offender GPS/EM is very effective in reducing sexual recidivism. Findings suggest that public perceptions of effectiveness are partially driven by myths and also that parents are unsure of this strategy. The analysis contributes to the growing body of knowledge on public perceptions of GPS/EM to manage sex offenders in communities. Implications of the study and areas for future research are discussed in light of the findings.

Top