The Effectiveness of Power Tool Cleaning as an Alternative to Abrasive Blasting
1995-06-01
Lamar Avenue Houston, TX 77251 3M Building Service and Cleaning Products Division Building 223-65-03 St. Paul, MN 55144-1000 Marindus Company P. O...Mill Scale Removal with 3M Brand Heavy Duty RotoPeen Flap Wheel”;”Scotch-Brite” Surface Conditioning Products, 3M Building Service and Cleaning ... Products Division. 18. “The Dilemma of Removing Lead-Based Paint,” January 1988, p. 34-35. Specifications: ASTM TEST METHODS: B1 17, Salt Spray (Fog
Clean Energy Policy Basics | State, Local, and Tribal Governments | NREL
their clean energy goals. To create effective strategies, it is helpful to understand how to build a those directed towards market expansion and saturation. To build such a policy portfolio at the state
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hun, Diana E.
The US–China Clean Energy Research Center (CERC) was launched in 2009 by US Energy Secretary Steven Chu, Chinese Minister of Science and Technology Wan Gang, and Chinese National Energy Agency Administrator Zhang Guobao. This 5-year collaboration emerged from the fact that the United States and China are the world’s largest energy producers, energy consumers, and greenhouse gas emitters, and that their joint effort could have significant positive repercussions worldwide. CERC’s main goal is to develop and deploy clean energy technologies that will help both countries meet energy and climate challenges. Three consortia were established to address the most pressing energy-relatedmore » research areas: Advanced Coal Technology, Clean Vehicles, and Building Energy Efficiency (BEE). The project discussed in this report was part of the CERC-BEE consortia; its objective was to lower energy use in buildings by developing and evaluating technologies that improve the cost-effectiveness of air barrier systems for building envelopes.« less
TiO2-SiO2 Coatings with a Low Content of AuNPs for Producing Self-Cleaning Building Materials
Gil, M. L. Almoraima; Mosquera, María J.
2018-01-01
The high pollution levels in our cities are producing a significant increase of dust on buildings. An application of photoactive coatings on building materials can produce buildings with self-cleaning surfaces. In this study, we have developed a simple sol-gel route for producing Au-TiO2/SiO2 photocatalysts with application on buildings. The gold nanoparticles (AuNPs) improved the TiO2 photoactivity under solar radiation because they promoted absorption in the visible range. We varied the content of AuNPs in the sols under study, in order to investigate their effect on self-cleaning properties. The sols obtained were sprayed on a common building stone, producing coatings which adhere firmly to the stone and preserve their aesthetic qualities. We studied the decolourization efficiency of the photocatalysts under study against methylene blue and against soot (a real staining agent for buildings). Finally, we established that the coating with an intermediate Au content presented the best self-cleaning performance, due to the role played by its structure and texture on its photoactivity. PMID:29558437
Supporting Effective Feed-in Tariff Development in Malaysia
DOE Office of Scientific and Technical Information (OSTI.GOV)
Since 2011, Malaysia's overarching policy framework for clean energy development, the New Energy Policy, has led to significant deployment of renewable energy and energy efficiency. Building on the New Energy Policy, Malaysia mandated adoption of a renewable energy feed-in tariff (FiT) mechanism under the 2011 Renewable Energy Act. In 2013, Malaysia's Sustainable Energy Development Authority partnered with the Clean Energy Solutions Center and the Clean Energy Regulators Initiative (CERI), via the Ask an Expert service, to implement FiT policies and expand renewable energy development. Through collaboration between the government of Malaysia and the Clean Energy Solutions Center, concrete policy actionmore » was supported and implemented, building a strong framework to expand and catalyze clean energy development.« less
Develop an Indoor Air Quality Program in Your School
Effective cleaning and maintenance procedures are critical to protecting building systems and building occupants. Student, teacher and staff health and productivity can suffer when school building systems fail to operate as designed
Helping International Governments and Organizations Build a Clean Energy
Future | Working with Us | NREL Helping International Governments and Organizations Build a Clean Energy Future Helping International Governments and Organizations Build a Clean Energy Future
Helping Research Organizations Build a Clean Energy Future | Working with
Us | NREL Helping Research Organizations Build a Clean Energy Future Helping Research Organizations Build a Clean Energy Future Partner with NREL to accelerate the research and development of your
1. LOOKING WEST TOWARD OIL/CLEANING SUPPLY BUILDING (SIDING AND ROOF ...
1. LOOKING WEST TOWARD OIL/CLEANING SUPPLY BUILDING (SIDING AND ROOF VISIBLE TO THE LEFT); GAS PUMP SHED IN CENTER (IN SHADOWS). - Standard Lime & Stone Quarry, Oil-Cleaning Supply Building, County Route 27, Millville, Jefferson County, WV
Producing lasting amphiphobic building surfaces with self-cleaning properties
NASA Astrophysics Data System (ADS)
Facio, Dario S.; Carrascosa, Luis A. M.; Mosquera, María J.
2017-06-01
Nowadays, producing building surfaces that prevent water and oil uptake and which present self-cleaning activity is still a challenge. In this study, amphiphobic (superhydrophobic and oleophobic) building surfaces were successfully produced. A simple and low-cost process was developed, which is applicable to large-scale building surfaces, according the following procedure: (1) by spraying a SiO2 nanocomposite which produces a closely-packed nanoparticle uniform topography; (2) by functionalizing the previous coating with a fluorinated alkoxysilane, producing high hydrophobicity and oleophobicity. The formation of a Cassie-Baxter regime, in which air pockets could be trapped between the aggregates of particles, was confirmed by topographic study. The building surface demonstrated an excellent self-cleaning performance. Finally, the surface presented lasting superhydrophobicity with high stability against successive attachment/detachment force cycles. This high durability can be explained by the effective grafting of the silica nanocomposite coating skeleton with the substrate, and with the additional fluorinated coating produced by condensation reactions.
The effect of ozonization on furniture dust: microbial content and immunotoxicity in vitro.
Huttunen, Kati; Kauhanen, Eeva; Meklin, Teija; Vepsäläinen, Asko; Hirvonen, Maija-Riitta; Hyvärinen, Anne; Nevalainen, Aino
2010-05-01
Moisture and mold problems in buildings contaminate also the furniture and other movable property. If cleaning of the contaminated furniture is neglected, it may continue to cause problems to the occupants even after the moisture-damage repairs. The aim of this study was to determine the effectiveness of high-efficiency ozone treatment in cleaning of the furniture from moisture-damaged buildings. In addition, the effectiveness of two cleaning methods was compared. Samples were vacuumed from the padded areas before and after the treatment. The microbial flora and concentrations in the dust sample were determined by quantitative cultivation and QPCR-methods. The immunotoxic potential of the dust samples was analyzed by measuring effects on cell viability and production of inflammatory mediators in vitro. Concentrations of viable microbes decreased significantly in most of the samples after cleaning. Cleaning with combined steam wash and ozonisation was more effective method than ozonising alone, but the difference was not statistically significant. Detection of fungal species with PCR showed a slight but nonsignificant decrease in concentrations after the cleaning. The immunotoxic potential of the collected dust decreased significantly in most of the samples. However, in a small subgroup of samples, increased concentrations of microbes and immunotoxicological activity were detected. This study shows that a transportable cleaning unit with high-efficiency ozonising is in most cases effective in decreasing the concentrations of viable microbes and immunotoxicological activity of the furniture dust. However, the method does not destroy or remove all fungal material present in the dust, as detected with QPCR analysis, and in some cases the cleaning procedure may increase the microbial concentrations and immunotoxicity of the dust. Copyright 2010 Elsevier B.V. All rights reserved.
A perspective study on green cleaning for Malaysian public hospital
NASA Astrophysics Data System (ADS)
Ramli, N. A.; Zawawi, E. M.; Arif, N. R. M.; Mahbob, N. S.; Sulaiman, Z.; Zainol, N. N.
2018-02-01
Cleaning being a major contributor to the operations and maintenance expenditure and also Indoor Environmental Quality (IEQ) issues. Improper and ineffective cleaning can harm the environment and poses greatest risk to health. The use of traditional cleaning products presents a variety of human health and ecological concerns; and may contribute to poor IEQ. As an effort to reduce the issue of operations and maintenance costs and IEQ issues in a building, it is important to establish a green cleaning programme to ensure that the buildings are cleaned in a green way. Numbers of scholars has pointed out the factors which had prevented the green cleaning implementation in hospital buildings. Nonetheless, the significance of these factors has yet to be practically explored in the Malaysian context. Hence, the aim of the paper is to identify the most critical factor that prevents the implementation of green cleaning in Malaysian hospital building. A questionnaire survey and personal communication (i.e. interview) was conducted which involved two groups of respondents. They are the hospital maintenance staff (Cleansing Service Department) and cleaning contractors. Frequency and criticality index calculations have been used to rank these factors according to the level of importance. The result showed that an “unclear components and requirements of green cleaning” indicated as the most critical factor that prevent the implementation of green cleaning in Malaysian hospital building. In the concern for a successful implementation of green cleaning, it is hope that the findings of these studies can be enlightenment to the cleaning contractors as well as the hospital maintenance management team in Malaysia.
Cleaning products and air fresheners: exposure to primary and secondary air pollutants
NASA Astrophysics Data System (ADS)
Nazaroff, William W.; Weschler, Charles J.
Building occupants, including cleaning personnel, are exposed to a wide variety of airborne chemicals when cleaning agents and air fresheners are used in buildings. Certain of these chemicals are listed by the state of California as toxic air contaminants (TACs) and a subset of these are regulated by the US federal government as hazardous air pollutants (HAPs). California's Proposition 65 list of species recognized as carcinogens or reproductive toxicants also includes constituents of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical, which reacts rapidly with organics, leading to the formation of other potentially toxic air pollutants. Indoor reactive chemistry involving the nitrate radical and cleaning-product constituents is also of concern, since it produces organic nitrates as well as some of the same oxidation products generated by ozone and hydroxyl radicals. Few studies have directly addressed the indoor concentrations of TACs that might result from primary emissions or secondary pollutant formation following the use of cleaning agents and air fresheners. In this paper, we combine direct empirical evidence with the basic principles of indoor pollutant behavior and with information from relevant studies, to analyze and critically assess air pollutant exposures resulting from the use of cleaning products and air fresheners. Attention is focused on compounds that are listed as HAPs, TACs or Proposition 65 carcinogens/reproductive toxicants and compounds that can readily react to generate secondary pollutants. The toxicity of many of these secondary pollutants has yet to be evaluated. The inhalation intake of airborne organic compounds from cleaning product use is estimated to be of the order of 10 mg d -1 person -1 in California. More than two dozen research articles present evidence of adverse health effects from inhalation exposure associated with cleaning or cleaning products. Exposure to primary and secondary pollutants depends on the complex interplay of many sets of factors and processes, including cleaning product composition, usage, building occupancy, emission dynamics, transport and mixing, building ventilation, sorptive interactions with building surfaces, and reactive chemistry. Current understanding is sufficient to describe the influence of these variables qualitatively in most cases and quantitatively in a few.
NASA Astrophysics Data System (ADS)
Haghighat, Fariborz; Lee, Chang-Seo; Pant, Bhuvan; Bolourani, Golnoush; Lakdawala, Ness; Bastani, Arash
There are increased demands for security, sustainability and indoor air quality in today's building design, construction, operation and maintenance. Installation of air cleaning systems can improve the indoor air quality by reducing the air pollution levels, and enhance the building security against sudden release of chemical and/or biological agents. At the same time, air cleaning techniques may reduce the building energy consumption by reducing the outdoor air supply rate, hence lowering the needs for conditioning of outdoor air. While the air filtration of particulate matter is well standardized, the standards against which the performance of air cleaning for gaseous contaminants is measured or classified are still under development. This study examined the performance of various granular activated carbons (GACs) for the removal of volatile organic compounds (VOCs) from mechanically ventilated buildings. Eight different GACs (three virgin and five impregnated) were tested against toluene using a dynamic test system. The virgin GACs showed better performance than impregnated ones, the percentage and the type of impregnation affected the removal efficiencies. Tests were also conducted with selected GACs against toluene, cyclohexane and ethyl acetate at relative humidity (RH) values of 30%, 50% and 70%. The effect of humidity was dependant on the VOC used. Both for toluene and cyclohexane, the removal efficiency decreased as RH increased. However, higher humidity showed a positive impact on the removal of ethyl acetate.
NREL Incubator Alliance Helps Entrepreneurs Build Clean Energy Solutions
Incubator Alliance Helps Entrepreneurs Build Clean Energy Solutions For more information contact alliance. "We can do that by helping companies succeed." The incubators' objective is to build
Photocatalytic oxide films in the built environment
NASA Astrophysics Data System (ADS)
Österlund, Lars; Topalian, Zareh
2014-11-01
The possibility to increase human comfort in buildings is a powerful driving force for the introduction of new technology. Among other things our sense of comfort depends on air quality, temperature, lighting level, and the possibility of having visual contact between indoors and outdoors. Indeed there is an intimate connection between energy, comfort, and health issues in the built environment, leading to a need for intelligent building materials and green architecture. Photocatalytic materials can be applied as coatings, filters, and be embedded in building materials to provide self-cleaning, antibacterial, air cleaning, deodorizing, and water cleaning functions utilizing either solar light or artificial illumination sources - either already present in buildings, or by purposefully designed luminaries. Huge improvements in indoor comfort can thus be made, and also alleviate negative health effects associated with buildings, such as the sick-house syndrome. At the same time huge cost savings can be made by reducing maintenance costs. Photocatalytic oxides can be chemically modified by changing their acid-base surface properties, which can be used to overcome deactivation problems commonly encountered for TiO2 in air cleaning applications. In addition, the wetting properties of oxides can be tailored by surface chemical modifications and thus be made e.g. oleophobic and water repellent. Here we show results of surface acid modified TiO2 coatings on various substrates by means of photo-fixation of surface sulfate species by a method invented in our group. In particular, we show that such surface treatments of photocatalytic concrete made by mixing TiO2 nanoparticles in reactive concrete powders result in concrete surfaces with beneficial self-cleaning properties. We propose that such approaches are feasible for a number of applications in the built environment, including glass, tiles, sheet metals, plastics, etc.
Assessing the effects of UVA photocatalysis on soot-coated TiO2-containing mortars.
De la Rosa, José M; Miller, Ana Z; Pozo-Antonio, J Santiago; González-Pérez, José A; Jiménez-Morillo, Nicasio T; Dionisio, Amelia
2017-12-15
The deposition of soot on building surfaces darkens their colour and leads to undesirable black crusts, which are one of the most serious problems on the conservation of built cultural heritage. As a preventive strategy, self-cleaning systems based on the use of titanium dioxide (TiO 2 ) coatings have been employed on building materials for degrading organic compounds deposited on building surfaces, improving their durability and performance. In this study, the self-cleaning effect of TiO 2 -containing mortars coated with diesel soot has been appraised under laboratory conditions. The mortar samples were manufactured using lime putty and two different doses of TiO 2 (2.5% and 5%). The lime mortars were then coated with diesel engine soot and irradiated with ultraviolet A (UVA) illumination for 30days. The photocatalytic efficiency was evaluated by visual inspection, field emission scanning electron microscopy (FESEM) and colour spectrophotometry. Changes in the chemical composition of the soot particles (including persistent organic pollutants) were assessed by analytical pyrolysis (Py-GC/MS) and solid state 13 C NMR spectroscopy. The FESEM and colour spectrophotometry revealed that the soot-coated TiO 2 -containing mortars promoted a self-cleaning effect after UVA irradiation. The combination of analytical pyrolysis and 13 C solid state NMR showed that the UVA irradiation caused the cracking of polycyclic aromatic structures and n-alkyl compounds of the diesel soot and its transformation into methyl polymers. Our findings also revealed that the inclusion of TiO 2 in the lime mortar formulations catalysed these transformations promoting the self-cleaning of the soot-stained mortars. The combined action of TiO 2 and UVA irradiation is a promising proxy to clean lime mortars affected by soot deposition. Copyright © 2017 Elsevier B.V. All rights reserved.
Photocatalytic Solutions Create Self-Cleaning Surfaces
NASA Technical Reports Server (NTRS)
2013-01-01
A Stennis Space Center researcher investigating the effectiveness of photocatalytic materials for keeping the Center's buildings free of grime turned to a solution created by PURETi Inc. of New York City. Testing proved successful, and NASA and the company now share a Dual Use Technology partnership. PURETi's coatings keep surfaces clean and purify surrounding air, eliminating pollution, odors, and microbes.
30. LOOKING SOUTHEAST AT THE CLEAN STEEL PRODUCTION BUILDING WITH ...
30. LOOKING SOUTHEAST AT THE CLEAN STEEL PRODUCTION BUILDING WITH THE BOP SHOP IN BACKGROUND. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA
Not all that glitters is RMT in the forecasting of risk of portfolios in the Brazilian stock market
NASA Astrophysics Data System (ADS)
Sandoval, Leonidas; Bortoluzzo, Adriana Bruscato; Venezuela, Maria Kelly
2014-09-01
Using stocks of the Brazilian stock exchange (BM&F-Bovespa), we build portfolios of stocks based on Markowitz's theory and test the predicted and realized risks. This is done using the correlation matrices between stocks, and also using Random Matrix Theory in order to clean such correlation matrices from noise. We also calculate correlation matrices using a regression model in order to remove the effect of common market movements and their cleaned versions using Random Matrix Theory. This is done for years of both low and high volatility of the Brazilian stock market, from 2004 to 2012. The results show that the use of regression to subtract the market effect on returns greatly increases the accuracy of the prediction of risk, and that, although the cleaning of the correlation matrix often leads to portfolios that better predict risks, in periods of high volatility of the market this procedure may fail to do so. The results may be used in the assessment of the true risks when one builds a portfolio of stocks during periods of crisis.
Chiappini, L; Delery, L; Leoz, E; Brouard, B; Fagault, Y
2009-06-01
Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies. In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.
Serrano, Kate A; Martyny, John W; Kofford, Shalece; Contreras, John R; Van Dyke, Mike V
2012-01-01
This study was designed to determine how easily methamphetamine can be removed from clothing and building materials, utilizing different cleaning materials and methods. The study also addressed the penetration of methamphetamine into drywall and the ability of paints to encapsulate the methamphetamine on drywall. Clothing and building materials were contaminated in a stainless steel chamber by aerosolizing methamphetamine in a beaker heater. The amount of methamphetamine surface contamination was determined by sampling a grid pattern on the material prior to attempting to clean the materials. After cleaning, the materials were again sampled, and the degree of decontamination noted. We found that household clothing and response gear worn by first responders was easily decontaminated using a household detergent in a household washing machine. A single wash removed over 95% of the methamphetamine from these materials. The study also indicated that methamphetamine-contaminated, smooth non-porous surfaces can be easily cleaned to below detectable levels using only mild cleaners. More porous surfaces such as plywood and drywall were unlikely to be decontaminated to below regulatory levels even with three washes using a mild cleaner. This may be due to methamphetamine penetration into the paint on these surfaces. Evaluation of methamphetamine contamination on drywall indicated that approximately 40% of the methamphetamine was removed using a wipe, while another 60% remained in the paint layer. Stronger cleaners such as those with active ingredients including sodium hypochlorite or quaternary ammonia and commercial decontamination agents were more effective than mild detergent-based cleaners and may reduce methamphetamine contamination to below regulatory levels. Results from the encapsulation studies indicate that sprayed on oil-based paint will encapsulate methamphetamine on drywall and plywood surfaces up to 4.5 months, while latex paints were less effective.
Energy Saving Homes and Buildings - Continuum Magazine | NREL
Spring 2014 / Issue 6 Continuum. Clean Energy Innovation at NREL Energy Saving Homes and Buildings Continuum showcases NREL's unique research capabilities and most impactful clean energy innovations. Dan Says From our director Dan says NREL Provides a Foundation for Home Energy Performance 01 NREL Provides
NASA Astrophysics Data System (ADS)
Palmiste, Ü.; Voll, H.
2017-10-01
The development of advanced air cleaning technologies aims to reduce building energy consumption by reduction of outdoor air flow rates while keeping the indoor air quality at an acceptable level by air cleaning. Photocatalytic oxidation is an emerging technology for gas-phase air cleaning that can be applied in a standalone unit or a subsystem of a building mechanical ventilation system. Quantitative information on photocatalytic reactor performance is required to evaluate the technical and economic viability of the advanced air cleaning by PCO technology as an energy conservation measure in a building air conditioning system. Photocatalytic reactors applying optical fibers as light guide or photocatalyst coating support have been reported as an approach to address the current light utilization problems and thus, improve the overall efficiency. The aim of the paper is to present a preliminary evaluation on continuous flow optical fiber photocatalytic reactors based on performance indicators commonly applied for air cleaners. Based on experimental data, monolith-type optical fiber reactor performance surpasses annular-type optical fiber reactors in single-pass removal efficiency, clean air delivery rate and operating cost efficiency.
Data and Tools | State, Local, and Tribal Governments | NREL
governments with making informed decisions about clean energy policy and projects. Photo of two people in in our podcasts Clean Energy Policy Basics Understand how to build a clean energy policy portfolio reduce petroleum consumption. Clean Energy Solutions Center No-cost expert policy assistance, webinars
14. VIEW OF WEST WALL OF CLEAN ROOM (102) SHOWING ...
14. VIEW OF WEST WALL OF CLEAN ROOM (102) SHOWING VIEWING WINDOWS IN WEST FALSE PARTION WALL, WEST WALL OF CLEAN ROOM (102), AND ROLLS OF PLASTIC WRAP FOR COVERING CLEANED FAIRING ASSEMBLY - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Lambert, Mark; Butt, Paul; Cheney, Tanya; Tatone, Fabrizio Antonio; Callaby, Rebecca; Rabie, André; Gosling, Rebecca J.; Fordon, Steve; Crocker, Graham; Davies, Robert H.; Smith, Richard Piers
2017-01-01
Salmonella is the second most commonly reported zoonotic gastrointestinal pathogen in the European Union, and a significant proportion of the cases are linked to the consumption of contaminated pork. Reduction of Salmonella at the farm level helps to mininimise the contamination pressure at the slaughterhouse, and therefore the number of Salmonella bacteria entering the food chain. Cleaning and disinfection (C&D) between batches of pigs is an intervention measure that has potential to reduce the transmission of Salmonella contamination within farms. In this study, two pig finisher buildings in each of 10 Salmonella positive farms were sampled pre-C&D, post-C&D, post-restocking with the following batch of pigs, and shortly before these pigs were sent to slaughter. The incoming batch of pigs was also sampled before it reached the study building (pre-restocking). At each visit, pooled and individual faecal samples were collected and Salmonella isolation was carried out according to an ISO 6579:2002 Annex D-based method. One building on each farm (intervention) was cleaned and disinfected according to a rigorous protocol consisting of several steps and a Defra-approved disinfectant used at the General Orders concentration, whilst the other building (control) was cleaned and disinfected as per normal farm routine. At the post-C&D visit, Enterobacteriaceae and total bacterial counts were determined to evaluate residual faecal contamination and general hygiene levels. Rodent specialists visited the farms before and after C&D and rodent carcasses were collected for Salmonella testing. The intervention buildings were significantly less likely (p = 0.004) to be positive for Salmonella after C&D. The pre-restocking pigs had the highest likelihood (p<0.001) of being Salmonella positive (often with multiple serovars) and there was no significant difference between intervention and control buildings in Salmonella prevalence at the post-restocking visit (p = 0.199). However, the pigs housed in the intervention buildings were significantly less likely (p = 0.004) to be positive for Salmonella at slaughter age. Multivariable analysis suggested that cleaning all fixtures of buildings, leaving the pens empty for 2–3 days and using an effective disinfectant are factors significantly improving the likelihood of removing Salmonella contamination during C&D. Signs of rodents were recorded in all farms, but rodent activity and harbourage availability decreased between visits. All the rats tested were Salmonella negative. S. Typhimurium or its monophasic variants were isolated from 6 mouse carcasses in 3 farms where the same serovars were isolated from pigs. This study demonstrates that an appropriate C&D programme significantly reduces the likelihood of residual contamination in Salmonella positive pig buildings, and suggests a significant reduction in the prevalence of Salmonella in the pigs in appropriately cleaned and disinfected buildings when sampled before slaughter. Due to a high prevalence of infection in replacement pigs, control of Salmonella in pig farms is challenging. Rodents may also contribute to the carry-over of infection between batches. C&D is a useful measure to help reduce the number of infected pigs going to the slaughterhouse, but should be supplemented by other control measures along the pig breeding and production chain. PMID:28594930
Tephra fall clean-up in urban environments
NASA Astrophysics Data System (ADS)
Hayes, Josh L.; Wilson, Thomas M.; Magill, Christina
2015-10-01
Tephra falls impact urban communities by disrupting transport systems, contaminating and damaging buildings and infrastructures, and are potentially hazardous to human health. Therefore, prompt and effective tephra clean-up measures are an essential component of an urban community's response to tephra fall. This paper reviews case studies of tephra clean-up operations in urban environments around the world, spanning 50 years. It identifies methods used in tephra clean-up and assesses a range of empirical relationships between level of tephra accumulation and clean-up metrics such as collected tephra volume, costs, and duration of operations. Results indicate the volume of tephra collected from urban areas is proportional to tephra accumulation. Urban areas with small tephra accumulations (1,000 m3/km2 or an average of 1 mm thickness) may collect < 1% of the total deposit, whereas urban areas which experience large accumulations (> 50,000 m3/km2 or an average of 50 mm thickness) remove up to 80%. This relationship can inform impact and risk assessments by providing an estimate of the likely response required for a given tephra fall. No strong relationship was found between tephra fall accumulation and clean-up cost or duration for urban environments which received one-off tephra falls, suggesting that these aspects of tephra fall clean-up operations are context specific. Importantly, this study highlights the advantage of effective planning for tephra clean-up and disposal in potentially exposed areas.
Precision Clean Hardware: Maintenance of Fluid Systems Cleanliness
NASA Technical Reports Server (NTRS)
Sharp, Sheila; Pedley, Mike; Bond, Tim; Quaglino, Joseph; Lorenz, Mary Jo; Bentz, Michael; Banta, Richard; Tolliver, Nancy; Golden, John; Levesque, Ray
2003-01-01
The ISS fluid systems are so complex that fluid system cleanliness cannot be verified at the assembly level. A "build clean / maintain clean" approach was used by all major fluid systems: Verify cleanliness at the detail and subassembly level. Maintain cleanliness during assembly.
Tolvanen, Riina; Lundén, Janne; Hörman, Ari; Korkeala, Hannu
2009-02-01
Ultrasonic cleaning of a conveyor belt was studied by building a pilot-scale conveyor with an ultrasonic cleaning bath. A piece of the stainless steel conveyor belt was contaminated with meat-based soil and Listeria monocytogenes strains (V1, V3, and B9) and incubated for 72 h to allow bacteria to attach to the conveyor belt surfaces. The effect of ultrasound with a potassium hydroxide-based cleaning detergent was determined by using the cleaning bath at 45 and 50 degrees C for 30 s with and without ultrasound. The detachment of L. monocytogenes from the conveyor belt caused by the ultrasonic treatment was significantly greater at 45 degrees C (independent samples t test, P < 0.001) and at 50 degrees C (independent samples t test, P = 0.04) than without ultrasound. Ultrasonic cleaning efficiency was tested with different cleaning durations (10, 15, 20, and 30 s) and temperatures (30, 45, and 50 degrees C). The differences in the log reduction between cleaning treatments were analyzed by analysis of variance with Tamhane's T2 posthoc test using SPSS (Chicago, IL). The lengthening of the treatment time from 10 to 30 s did not significantly increase the detachment of L. monocytogenes (ANOVA 0.633). At 30 degrees C and at the longest time tested (30 s), the treatment reduced L. monocytogenes counts by only 2.68 log units. However, an increase in temperature from 30 to 50 degrees C improved the effect of the ultrasonic treatment significantly (P < 0.01). Ultrasonic cleaning for 10 s at 50 degrees C reduced L. monocytogenes counts by more than 5 log units. These results indicate that ultrasonic cleaning of a conveyor belt is effective even with short treatment times.
10. SETTLING TANK CLEANOUT DOORS, SOUTH SIDE; USED TO CLEAN ...
10. SETTLING TANK CLEAN-OUT DOORS, SOUTH SIDE; USED TO CLEAN DEBRIS FROM SURFACE OF WATER IN SETTLING TANK. - Hondius Water Line, 1.6 miles Northwest of Park headquarters building & 1 mile Northwest of Beaver Meadows entrance station, Estes Park, Larimer County, CO
NASA Astrophysics Data System (ADS)
Carmona-Quiroga, P. M.; Martínez-Ramírez, S.; Viles, H. A.
2018-03-01
This study aimed to test the performance under long-term working conditions of a commercial self-cleaning coating, a water-based TiO2 sol, on three building materials important in recent and older European heritage; Portland limestone, Woodkirk sandstone and concrete. First, the compatibility of the coating (effect on petrophysical properties) with the substrates was demonstrated by examining aesthetic properties and water vapour permeability of the building materials and secondly, the self-cleaning ability of the TiO2 nanoparticles in degrading artificial stain (rhodamine B) under UV light was evaluated. Finally, the durability (lasting performance) of photocatalytic activity was assessed during one year of outdoor exposure trial and 2000 h of accelerated ageing in a chamber with UV radiation and condensation cycles. Results showed that photocatalytic activity was unaltered on concrete, whereas on sandstone, particularly after artificial ageing, it was reduced due to the removal of nanoparticles from the surface. On limestone, a decrease of TiO2 content was observed but photodegradation efficiency (ability to perform as self-cleaner) seemed not to be affected.
State and local governments interested in developing a financing program can use this Excel tool to support energy efficiency and clean energy improvements for large numbers of buildings within their jurisdiction.
Seeliger, Julia; Lipski, Mariusz; Wójcicka, Anna; Gedrange, Tomasz; Woźniak, Krzysztof
2016-01-01
Braces as foreign bodies in the mouth carry a risk of side effects and toxicity to the human body. This article presents the results indicating the possible toxic effects of tools used for cleaning the enamel after the completion of orthodontic treatment. The studies were carried out in vitro. The procedure of enamel etching, bonding orthodontic metal brackets, and enamel cleaning after their removal was performed under laboratory conditions. The enamel microstructure and elements present on its surface were evaluated using the scanning electron microscope (SEM). Silicon and aluminium were found in addition to the tooth building elements. PMID:27766265
Phosphorus and water recovery by a novel osmotic membrane bioreactor-reverse osmosis system.
Luo, Wenhai; Hai, Faisal I; Price, William E; Guo, Wenshan; Ngo, Hao H; Yamamoto, Kazuo; Nghiem, Long D
2016-01-01
An osmotic membrane bioreactor-reverse osmosis (OMBR-RO) hybrid system integrated with periodic microfiltration (MF) extraction was evaluated for simultaneous phosphorus and clean water recovery from raw sewage. In this hybrid system, the forward osmosis membrane effectively retained inorganic salts and phosphate in the bioreactor, while the MF membrane periodically bled them out for phosphorus recovery with pH adjustment. The RO process was used for draw solute recovery and clean water production. Results show that phosphorus recuperation from the MF permeate was most effective when the solution pH was adjusted to 10, whereby the recovered precipitate contained 15-20% (wt/wt) of phosphorus. Periodic MF extraction also limited salinity build-up in the bioreactor, resulting in a stable biological performance and an increase in water flux during OMBR operation. Despite the build-up of organic matter and ammonia in the draw solution, OMBR-RO allowed for the recovery of high quality reused water. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.
Video: NREL and Buildings Research - Continuum Magazine | NREL
solutions to improve the energy efficiency of both residential and commercial buildings, and to accelerate the integration of clean energy technologies with buildings. NREL's commercial buildings research focuses on providing large institutional and private sector commercial building owners with tools
21 CFR 225.120 - Buildings and grounds.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 4 2010-04-01 2010-04-01 false Buildings and grounds. 225.120 Section 225.120... Buildings and grounds. Buildings used for production of medicated feed shall provide adequate space for... routine maintenance and cleaning of equipment. Buildings and grounds shall be constructed and maintained...
Clean Cities: Building Partnerships to Reduce Petroleum Use in Transportation (Brochure)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2012-03-01
This fact sheet provides an overview of the U.S. Department of Energy's Clean Cities program, which builds partnerships to reduce petroleum use in transportation in communities across the country. The U.S. Department of Energy's Clean Cities initiative advances the nation's economic, environmental, and energy security by supporting local actions to reduce petroleum consumption in transportation. Clean Cities accomplishes this work through the activities of nearly 100 local coalitions. These coalitions provide resources and technical assistance in the deployment of alternative and renewable fuels, idle-reduction measures, fuel economy improvements, and new transportation technologies, as they emerge. Clean Cities overarching goal ismore » to reduce U.S. petroleum use by 2.5 billion gallons per year by 2020. To achieve this goal, Clean Cities employs three strategies: (1) Replace petroleum with alternative and renewable fuels, including natural gas, propane, electricity, ethanol, biodiesel, and hydrogen; (2) Reduce petroleum consumption through smarter driving practices and fuel economy improvements; and (3) Eliminate petroleum use through idle reduction and other fuel-saving technologies and practices.« less
Drag of Clean and Fouled Net Panels – Measurements and Parameterization of Fouling
Gansel, Lars Christian; Plew, David R.; Endresen, Per Christian; Olsen, Anna Ivanova; Misimi, Ekrem; Guenther, Jana; Jensen, Østen
2015-01-01
Biofouling is a serious problem in marine aquaculture and it has a number of negative impacts including increased forces on aquaculture structures and reduced water exchange across nets. This in turn affects the behavior of fish cages in waves and currents and has an impact on the water volume and quality inside net pens. Even though these negative effects are acknowledged by the research community and governmental institutions, there is limited knowledge about fouling related effects on the flow past nets, and more detailed investigations distinguishing between different fouling types have been called for. This study evaluates the effect of hydroids, an important fouling organism in Norwegian aquaculture, on the forces acting on net panels. Drag forces on clean and fouled nets were measured in a flume tank, and net solidity including effect of fouling were determined using image analysis. The relationship between net solidity and drag was assessed, and it was found that a solidity increase due to hydroids caused less additional drag than a similar increase caused by change in clean net parameters. For solidities tested in this study, the difference in drag force increase could be as high as 43% between fouled and clean nets with same solidity. The relationship between solidity and drag force is well described by exponential functions for clean as well as for fouled nets. A method is proposed to parameterize the effect of fouling in terms of an increase in net solidity. This allows existing numerical methods developed for clean nets to be used to model the effects of biofouling on nets. Measurements with other types of fouling can be added to build a database on effects of the accumulation of different fouling organisms on aquaculture nets. PMID:26151907
31. INTERIOR VIEW OF PLATFORM ALONG WESTERN WALL OF CLEAN ...
31. INTERIOR VIEW OF PLATFORM ALONG WESTERN WALL OF CLEAN STEEL PRODUCTION BUILDING. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA
NASA Astrophysics Data System (ADS)
Izie Adiana Abidin, Nur; Aminuddin, Eeydzah; Zakaria, Rozana; Mazzuana Shamsuddin, Siti; Sahamir, Shaza Rina; Shahzaib, Jam; Nafis Abas, Darul
2018-04-01
Campus university building is the Higher Learning Institution (HLI) involves complex activities and operations, conserving the energy has become paramount important. There are several efforts taken by universities to improve its current energy use such as policy development, education, and adaption of energy conservation solution through retrofitting. This paper aims to highlight the importance of the criteria affecting in retrofitting of existing buildings with clean energy in order to achieve zero energy balance in buildings. The focus is given to the development of criteria for solar photovoltaic (solar PV), wind turbines and small-scale hydropower. A questionnaire survey was employed and distributed to the green building expert practitioner. Factor Analysis, Factor Score, and Weightage Factor were adapted as a method of analysis in order to produce the final result with weightage output for prioritization and ranking of the relevant criteria. The result performed assists to provide the stakeholders an overview of the important criteria that should be considered especially during the decision making to retrofit the existing buildings with clean energy resources. The criteria developed are also to establish a structured decision-making process and to ensure the selection of the decision or alternatives achieve the desired outcome.
9 CFR 147.24 - Cleaning and disinfecting.
Code of Federal Regulations, 2012 CFR
2012-01-01
... houses: (1) Remove all live “escaped” and dead birds from the building. Blow dust from equipment and...) Use cleaning agents and sanitizers that are registered by the U.S. Environmental Protection Agency as...
9 CFR 147.24 - Cleaning and disinfecting.
Code of Federal Regulations, 2013 CFR
2013-01-01
... houses: (1) Remove all live “escaped” and dead birds from the building. Blow dust from equipment and...) Use cleaning agents and sanitizers that are registered by the U.S. Environmental Protection Agency as...
9 CFR 147.24 - Cleaning and disinfecting.
Code of Federal Regulations, 2014 CFR
2014-01-01
... houses: (1) Remove all live “escaped” and dead birds from the building. Blow dust from equipment and...) Use cleaning agents and sanitizers that are registered by the U.S. Environmental Protection Agency as...
9 CFR 147.24 - Cleaning and disinfecting.
Code of Federal Regulations, 2011 CFR
2011-01-01
... houses: (1) Remove all live “escaped” and dead birds from the building. Blow dust from equipment and...) Use cleaning agents and sanitizers that are registered by the U.S. Environmental Protection Agency as...
Self-cleaning geopolymer concrete - A review
NASA Astrophysics Data System (ADS)
Norsaffirah Zailan, Siti; Mahmed, Norsuria; Bakri Abdullah, Mohd Mustafa Al; Sandu, Andrei Victor
2016-06-01
Concrete is the most widely used construction materials for building technology. However, cement production releases high amounts of carbon dioxide (CO2) to the atmosphere that leads to increasing the global warming. Thus, an alternative, environmental friendly construction material such as geopolymer concrete has been developed. Geopolymer concrete applies greener alternative binder, which is an innovative construction material that replaces the Portland cement. This technology introduced nano-particles such as nanoclay into the cement paste in order to improve their mechanical properties. The concrete materials also have been developed to be functioned as self-cleaning construction materials. The self-cleaning properties of the concrete are induced by introducing the photocatalytic materials such as titania (TiO2) and zinc oxide (ZnO). Self-cleaning concrete that contains those photocatalysts will be energized by ultraviolet (UV) radiation and accelerates the decomposition of organic particulates. Thus, the cleanliness of the building surfaces can be maintained and the air surrounding air pollution can be reduced. This paper briefly reviews about self-cleaning concrete.
Enabling Energy Efficiency in South Africa's Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-04-01
South Africa is leading a number of efforts to support a thriving economy while also reducing energy use. Increasing energy demand coupled with a highly energy intensive economy and energy inefficient industries provide the backdrop for strong government action underway in South Africa. This brochure details how the Clean Energy Solutions Center supported development of the Regulations on Allowance for the Energy Efficiency Savings legislation designed to provide a framework for effective energy efficiency regulation, incentives and energy reduction targets for South Africa's commercial buildings sector.
Tool to assist tribes that apply for Clean Air Act (CAA) funding to draft more effective work plans for projects that will develop tribal knowledge of air quality issues and build tribal expertise to manage air quality on tribal lands.
Learning Fire Investigation the Clean Way: The Virtual Experience
ERIC Educational Resources Information Center
Davies, Amanda; Dalgarno, Barney
2009-01-01
The effective teaching of fire investigation skills presents logistical challenges because of the difficulty of providing students with access to suitable fire damaged buildings so that they can undertake authentic investigation tasks. At Charles Sturt University (CSU), in the subject JST415, "Fire Investigation Cause and Origin…
Innovative Coatings Potentially Lower Facility Maintenance Costs
NASA Technical Reports Server (NTRS)
2013-01-01
Through extensive testing at Stennis Space Center, Nanocepts Inc. of Lexington, Kentucky, received key validation of the effectiveness of its photocatalytic coatings. Now a NASA Dual Use Technology partner, the company s commercial coatings offer unique environmental and medical benefits, and their self-cleaning properties help limit grime buildup on buildings.
De Filippis, Patrizia; Spinaci, Anna; Coia, Maura; Maggi, Oriana; Panà, Augusto
2003-01-01
The microbiological quality of the air indoor is influenced from various factors and one of the most important is represented from the maintenance of the conditioning systems. In this study it has been estimated the effectiveness of an intervention of cleaning and maintenance on the systems of conditioning of an university building executing sampling before and after such intervention. The two results were confronted and it is observed as the maintenance of the air conditioners has influenced on the quality of the air indoor.
2-in-1 shampoo technology: state-of-the-art shampoo and conditioner in one.
Rushton, H; Gummer, C L; Flasch, H
1994-01-01
Consumers have expressed a need for cleaning and conditioning in one step. Conventional shampoo technology using anionic surfactants and cationic conditioners results in charge interaction and complexing of the ingredients. Neither shampoo nor conditioners achieves the desired result. The successful solution was to incorporate charge neutral dimethicone conditioning ingredients, suspended as microfine droplets within complex crystal lattices, into anionic surfactant shampoo technology. The same solution has also been applied to amphoteric surfactant systems. This provides complete cleaning, and hair conditioning fully equal to separate conditioners without the problems of sebum interactions and conditioner build-up. This was achieved by keeping the dimethicone in suspension throughout the shampoo process. During rinsing, excess water breaks the crystalline lattice and allows deposition of the dimethicone droplets onto the hair. Full cleaning and conditioning are, therefore, achieved in one application. Dimethicone build-up is not encountered as subsequent washes first remove soil and previously deposited dimethicone. Neither do neutral dimethicones show any reactions with sebum. The development of effective 2-in-1 technology has had a major impact on shampoo technology and consumer habits and practices. This has significantly changed the way consumers care for their hair.
Department of Interior Focuses on Cleaning Products
A November 1998 effort to address concerns over the indoor air quality in their buildings in DC led the Department of the Interior (DOI) to initiate a contract for custodial services using environmentally preferable cleaning products and supplies.
Code of Federal Regulations, 2014 CFR
2014-04-01
... operation for their intended purpose. The building shall: (a) Provide adequate space for the orderly.... (c) Provide for adequate washing, cleaning, toilet, and locker facilities. Work areas and equipment...
Code of Federal Regulations, 2011 CFR
2011-04-01
... operation for their intended purpose. The building shall: (a) Provide adequate space for the orderly.... (c) Provide for adequate washing, cleaning, toilet, and locker facilities. Work areas and equipment...
Code of Federal Regulations, 2013 CFR
2013-04-01
... operation for their intended purpose. The building shall: (a) Provide adequate space for the orderly.... (c) Provide for adequate washing, cleaning, toilet, and locker facilities. Work areas and equipment...
NASA Astrophysics Data System (ADS)
Adelsberger, Kathleen
Energy is the basis for modern life. All modern technology from a simple coffee maker to massive industrial facilities is powered by energy. While the demand for energy is increasing, our planet is suffering from the consequences of using fossil fuels to generate electricity. Therefore, the world is looking at clean energy and solar power to minimize this effect on our environment. However, saving energy is extremely important even for clean energy. The more we save the less we have to generate. Heat retention in buildings is one step towards achieving passive heating. Therefore, efforts are made to prevent heat from escaping buildings through the glass during cold nights. Movable insulation is a way to increase the insulation value of the glass to reduce heat loss towards the outdoor. This thesis examines the performance of the aerogel-filled polycarbonate movable panels in the Ecohawks building, a building located on the west campus of The University of Kansas. Onsite tests were performed using air and surface temperature sensors to determine the effectiveness of the system. Computer simulations were run by Therm 7.2 simulation software to explore alternative design options. A cost analysis was also performed to evaluate the feasibility of utilizing movable insulation to reduce the heating bills during winter. Results showed that sealed movable insulation reduces heat loss through the glazing by 67.5%. Replacing aerogel with XPS panels reduces this percentage to 64.3%. However, it reduces the cost of the insulation material by 98%.
NASA Astrophysics Data System (ADS)
Cumpson, Peter J.; Sano, Naoko; Barlow, Anders J.; Portoles, Jose F.
2013-10-01
Mercury contamination and the build-up of carbonaceous contamination are two contributing factors to the instability observed in kilogram prototype masses. The kilogram prototypes that lie at the core of the dissemination of the SI base unit were manufactured in the late 19th century, and have polished surfaces. In papers IV and V of this series we developed a method for cleaning noble metal mass standards in air to remove carbonaceous contamination. At the core of this ‘UVOPS’ protocol is the application of UV light and ozone gas generated in situ in air. The precise nature of the carbonaceous contamination that builds up on such surfaces is difficult to mimic demonstrably or quickly on new test surfaces, yet data from such tests are needed to provide the final confidence to allow UVOPS to be applied to a real 19th century kilogram prototype. Therefore, in the present work we have applied the UVOPS method to clean a platinum avoirdupois pound mass standard, ‘RS2’, manufactured in the mid-19th century. This is thought to have been polished in a similar manner to the kilogram prototypes. To our knowledge this platinum surface has not previously been cleaned by any method. We used x-ray photoelectron spectroscopy to identify organic contamination, and weighing to quantify the mass lost at each application of the UVOPS procedure. The UVOPS procedure is shown to be very effective. It is likely that the redefinition of the kilogram will require mass comparisons in vacuum in the years to come. Therefore, in addition to UVOPS a cleaning method for use in vacuum will also be needed. We introduce and evaluate gas cluster ion-beam (GCIB) treatment as a potential method for cleaning reference masses in vacuum. Again, application of this GCIB cleaning to a real artefact, RS2, allows us to make a realistic evaluation of its performance. While it has some attractive features, we cannot recommend it for cleaning mass standards in its present form.
32. SOUTHEASTERN VIEW OF GAS CLEANING PLANT, WITH BOP SHOP ...
32. SOUTHEASTERN VIEW OF GAS CLEANING PLANT, WITH BOP SHOP IN BACKGROUND AND OPEN HEARTH STEELMAKING OFFICE BUILDING TO THE RIGHT. - U.S. Steel Duquesne Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Duquesne, Allegheny County, PA
PERFORMANCE TESTING OF AIR CLEANING PRODUCTS
The paper discuses the application of the Environmental Technology Verification (ETV) Program for products that clean ventilation air to the problem of protecting buildings from chemical and biological attack. This program is funded by the U.S. Environmental Protection Agency und...
31 CFR 11.6 - Terms of permit.
Code of Federal Regulations, 2012 CFR
2012-07-01
... vending facilities shall be operated in compliance with applicable health, sanitation, and building codes... normal cleaning, maintenance, and repair of the building structure in and adjacent to the vending...
31 CFR 11.6 - Terms of permit.
Code of Federal Regulations, 2011 CFR
2011-07-01
... vending facilities shall be operated in compliance with applicable health, sanitation, and building codes... normal cleaning, maintenance, and repair of the building structure in and adjacent to the vending...
31 CFR 11.6 - Terms of permit.
Code of Federal Regulations, 2014 CFR
2014-07-01
... vending facilities shall be operated in compliance with applicable health, sanitation, and building codes... normal cleaning, maintenance, and repair of the building structure in and adjacent to the vending...
34 CFR 395.35 - Terms of permit.
Code of Federal Regulations, 2012 CFR
2012-07-01
... health, sanitation, and building codes or ordinances. (e) The permit shall further provide that... to the State licensing agency for normal cleaning, maintenance, and repair of the building structure...
34 CFR 395.35 - Terms of permit.
Code of Federal Regulations, 2014 CFR
2014-07-01
... health, sanitation, and building codes or ordinances. (e) The permit shall further provide that... to the State licensing agency for normal cleaning, maintenance, and repair of the building structure...
The C3E Women in Clean Energy Symposium
Saylors-Laster, Kim; Kirsch, Emily; Brown, Sandra; Jordan, Rhonda; Mukherjee, Anuradha; Martin, Cheryl; Madden, Alice; Araujo, Kathy
2018-02-13
The Clean Energy Education & Empowerment initiative (C3E), provides a forum for thought leaders across the clean energy sector to devise innovative solutions to the nation's most pressing energy challenges. This year, the symposium was held at MIT's Media Lab in Cambridge, MA, on September 19-20, 2013. What sets the annual conference apart is its focus on building a strong community of professionals dedicated to advancing more women leaders in clean energy fields. By working to leverage the skills, talents and perspectives of women, the symposium helps to better position the U.S. to lead the global clean energy revolution.
13. EQUIPMENT USED IN CLEAN ROOM (102), INCLUDING ROYCO PARTICLE ...
13. EQUIPMENT USED IN CLEAN ROOM (102), INCLUDING ROYCO PARTICLE COUNTER (LEFT) AND STEREOSCOPE FOR MANUAL PARTICLE COUNTING (RIGHT) - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Building recycling rates through the informal sector.
Wilson, David C; Araba, Adebisi O; Chinwah, Kaine; Cheeseman, Christopher R
2009-02-01
Many developing country cities aspire to modern waste management systems, which are associated with relatively high recycling rates of clean, source separated materials. Most already have informal sector recycling systems, which are driven solely by the revenues derived from selling recovered materials, even though they are saving the formal sector money by reducing waste quantities. There is clear potential for 'win-win' co-operation between the formal and informal sectors, as providing support to the informal sector, to build recycling rates and to address some of the social issues could reduce the overall costs of waste management for the formal sector. This paper shows that recycling rates already achieved by the informal sector can be quite high, typically in the range from 20% to 50%; often up to half of this is in the form of clean, source separated materials collected directly from households and businesses by itinerant waste buyers. Four country case studies provide a number of lessons on how this solid foundation could be used to build high recycling rates of clean materials.
True Cost of Amateur Clean rooms
NASA Technical Reports Server (NTRS)
Ramsey, W. Lawrence
2005-01-01
This viewgraph document reviews the cost factors for clean rooms that are not professionally built, monitored or maintained. These amateur clean rooms are built because scientist and engineers desire to create a clean room to build a part of an experiment that requires a clean room, and the program manager is looking to save money. However, in the long run these clean rooms may not save money, as the cost of maintenance may be higher due to the cost of transporting the crews, and if the materials were of lesser quality, the cost of modifications may diminish any savings, and the product may not be of the same quality. Several examples are shown of the clean rooms that show some of the problems that can arise from amateur clean rooms.
Huneau-Salaün, A; Michel, V; Balaine, L; Petetin, I; Eono, F; Ecobichon, F; Bouquin, S Le
2010-04-01
1. The aim in this study was to evaluate cleaning and disinfection programmes in battery cage and on-floor layer houses in France. 2. Cleaning and disinfection efficiency was assessed by a visual evaluation of cleaning and a bacteriological monitoring of surface contamination from counts of thermotolerant streptococci on contact agar plates. 3. In battery cage houses, dropping belts, manure conveyors, and house floors remained highly contaminated due to poor cleaning in half of the buildings examined. 4. In on-floor houses, a high standard of cleaning was achieved but errors in the planning of cleaning and disinfection operations sometimes led to a high residual contamination of nest boxes and egg sorting tables.
Looking east at the basic oxygen furnace building with gas ...
Looking east at the basic oxygen furnace building with gas cleaning plants in foreground on the left and the right side of the furnace building. - U.S. Steel Edgar Thomson Works, Basic Oxygen Steelmaking Plant, Along Monongahela River, Braddock, Allegheny County, PA
Pollution damage to the Powell Building, Reston, Virginia
Doe, B.R.; Reddy, M.M.; Eggleston, J.R.
1999-01-01
Concrete column segments of the Powell Building (Reston, VA) exposed to the elements and wetted by precipitation were `cleaned' and roughened, but sheltered portions of the columns retained their smoothness and pollution accumulates, similar to observations for limestone, marble, and sandstone. Weathering effects on the columns were dominated by precipitation run-off and not the acidity of the precipitation. The process may be dry deposition of sulfur dioxide (SO2) and nitric oxides (NOx) that formed soluble salts in the presence of humid air or dew, salts that were removed by precipitation run-off.
33. FUEL HANDLING BUILDING (LOCATION A), INTERIOR LOOKING NORTH FROM ...
33. FUEL HANDLING BUILDING (LOCATION A), INTERIOR LOOKING NORTH FROM ABOVE CLEAN ROOM - Shippingport Atomic Power Station, On Ohio River, 25 miles Northwest of Pittsburgh, Shippingport, Beaver County, PA
Colour changes by laser irradiation of reddish building limestones
NASA Astrophysics Data System (ADS)
Grossi, C. M.; Benavente, D.
2016-10-01
We have used X-ray photoelectron spectroscopy (XPS) as a novel method to investigate the causes of colour changes in a reddish limestone under irradiation by a Q-switched Nd:YAG 1064 nm laser. We irradiated clean dry and wet surfaces of Pidramuelle Roja, a building stone frequently used in the Asturian heritage, at fluences ranging from 0.12 to 1.47 J cm-2. We measured the colour coordinates and undertook XPS analysis of the state of oxidation of iron both before and after irradiation. Visible colour changes and potential aesthetic damage occurred on dry surfaces from a fluence of 0.31 J cm-2, with the stone showing a greening effect and very intense darkening. The colour change on dry surfaces was considerably higher than on wet surfaces, which at the highest fluence (1.47 J cm-2) was also above the human visual detection threshold. The use of XPS demonstrated that the change in colour (chroma and hue) is associated with a reduction in the iron oxidation state on dry surfaces during laser irradiation. This points out to a potential routinary use of XPS to analyse causes of colour changes during laser cleaning in other types of coloured building stones.
2. WESTWARD VIEW OF LOW PURITY BULK OXYGEN BUILDING, AND ...
2. WESTWARD VIEW OF LOW PURITY BULK OXYGEN BUILDING, AND FERROMANGANESE GAS CLEANING PLANT ON LEFT. - U.S. Steel Duquesne Works, Fuel & Utilities Plant, Along Monongahela River, Duquesne, Allegheny County, PA
Residual Inequity: Assessing the Unintended Consequences of New York City’s Clean Heat Transition
Carrión, Daniel; Lee, W. Victoria; Hernández, Diana
2018-01-01
Energy policies and public health are intimately intertwined. In New York City, a series of policies, known as the Clean Heat Program (CHP), were designed to reduce air pollution by banning residual diesel fuel oils, #6 in 2015 and #4 by 2030. This measure is expected to yield environmental and public health benefits over time. While there is near-universal compliance with the #6 ban, a substantial number of buildings still use #4. In this paper, geographic analysis and qualitative interviews with stakeholders were used to interrogate the CHP’s policy implementation in Northern Manhattan and the Bronx. A total of 1724 (53%) of all residential residual fuel burning buildings are located in this region. Stakeholders reflected mostly on the need for the program, and overall reactions to its execution. Major findings include that government partnerships with non-governmental organizations were effectively employed. However, weaknesses with the policy were also identified, including missed opportunities for more rapid transitions away from residual fuels, unsuccessful outreach efforts, cost-prohibitive conversion opportunities, and (the perception of) a volatile energy market for clean fuels. Ultimately, this analysis serves as a case study of a unique and innovative urban policy initiative to improve air quality and, consequently, public health. PMID:29324717
Public-Private Partnerships for Clean Energy Manufacturing
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-09-01
As part of its mission, CEMI builds partnerships around strategic priorities to increase U.S. clean energy manufacturing competitiveness. This requires an “all-hands-on-deck” approach that involves the nation’s private and public sectors, universities, think tanks, and labor leaders working together.
Risk Management Programs under Clean Air Act Section 112(r): Guidance for Implementing Agencies
Accidental release prevention programs under section 112(r) of the Clean Air Act (CAA) are related to and build on activities under the Emergency Planning and Community Right-to-Know Act, and Occupational Safety and Health Administration standards.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saylors-Laster, Kim; Kirsch, Emily; Brown, Sandra
The Clean Energy Education & Empowerment initiative (C3E), provides a forum for thought leaders across the clean energy sector to devise innovative solutions to the nation's most pressing energy challenges. This year, the symposium was held at MIT's Media Lab in Cambridge, MA, on September 19-20, 2013. What sets the annual conference apart is its focus on building a strong community of professionals dedicated to advancing more women leaders in clean energy fields. By working to leverage the skills, talents and perspectives of women, the symposium helps to better position the U.S. to lead the global clean energy revolution.
Implementation Science to Accelerate Clean Cooking for Public Health
Rosenthal, Joshua; Balakrishnan, Kalpana; Bruce, Nigel; Chambers, David; Graham, Jay; Jack, Darby; Kline, Lydia; Masera, Omar; Mehta, Sumi; Mercado, Ilse Ruiz; Neta, Gila; Pattanayak, Subhrendu; Puzzolo, Elisa; Petach, Helen; Punturieri, Antonello; Rubinstein, Adolfo; Sage, Michael; Sturke, Rachel; Shankar, Anita; Sherr, Kenny; Smith, Kirk; Yadama, Gautam
2017-01-01
Summary: Clean cooking has emerged as a major concern for global health and development because of the enormous burden of disease caused by traditional cookstoves and fires. The World Health Organization has developed new indoor air quality guidelines that few homes will be able to achieve without replacing traditional methods with modern clean cooking technologies, including fuels and stoves. However, decades of experience with improved stove programs indicate that the challenge of modernizing cooking in impoverished communities includes a complex, multi-sectoral set of problems that require implementation research. The National Institutes of Health, in partnership with several government agencies and the Global Alliance for Clean Cookstoves, has launched the Clean Cooking Implementation Science Network that aims to address this issue. In this article, our focus is on building a knowledge base to accelerate scale-up and sustained use of the cleanest technologies in low- and middle-income countries. Implementation science provides a variety of analytical and planning tools to enhance effectiveness of clinical and public health interventions. These tools are being integrated with a growing body of knowledge and new research projects to yield new methods, consensus tools, and an evidence base to accelerate improvements in health promised by the renewed agenda of clean cooking. PMID:28055947
National Clean Fleets Partnership (Fact Sheet)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2012-01-01
Provides an overview of Clean Cities National Clean Fleets Partnership (NCFP). The NCFP is open to large private-sector companies that have fleet operations in multiple states. Companies that join the partnership receive customized assistance to reduce petroleum use through increased efficiency and use of alternative fuels. This initiative provides fleets with specialized resources, expertise, and support to successfully incorporate alternative fuels and fuel-saving measures into their operations. The National Clean Fleets Partnership builds on the established success of DOE's Clean Cities program, which reduces petroleum consumption at the community level through a nationwide network of coalitions that work with localmore » stakeholders. Developed with input from fleet managers, industry representatives, and Clean Cities coordinators, the National Clean Fleets Partnership goes one step further by working with large private-sector fleets.« less
Mossotti, Victor G.; Eldeeb, A. Raouf; Fries, Terry L.; Coombs, Mary Jane; Naude, Virginia N.; Soderberg, Lisa; Wheeler, George S.
2002-01-01
This report describes a scientific investigation of the effects of eight different cleaning techniques on the Berkshire Lee marble component of the facade of the East Center Pavilion at Philadelphia City Hall; the study was commissioned by the city of Philadelphia. The eight cleaning techniques evaluated in this study were power wash (proprietary gel detergent followed by water rinse under pressure), misting (treatment with potable, nebulized water for 24-36 hours), gommage (proprietary Thomann-Hanry low-pressure, air-driven, small-particle, dry abrasion), combination (gommage followed by misting), Armax (sodium bicarbonate delivered under pressure in a water wash), JOS (dolomite powder delivered in a low-pressure, rotary-vortex water wash), laser (thermal ablation), and dry ice (powdered-dry-ice abrasion delivered under pressure). In our study approximately 160 cores were removed from the building for laboratory analysis. We developed a computer program to analyze scanning-electron-micrograph images for the microscale surface roughness and other morphologic parameters of the stone surface, including the near-surface fracture density of the stone. An analysis of more than 1,100 samples cut from the cores provided a statistical basis for crafting the essential elements of a reduced-form, mixed-kinetics conceptual model that represents the deterioration of calcareous stone in terms of self-organized soiling and erosion patterns. This model, in turn, provided a basis for identifying the variables that are affected by the cleaning techniques and for evaluating the extent to which such variables influence the stability of the stone. The model recognizes three classes of variables that may influence the soiling load on the stone, including such exogenous environmental variables as airborne moisture, pollutant concentrations, and local aerodynamics, and such endogenous stone variables as surface chemistry and microstructure (fracturing, roughness, and so on). This study showed that morphologic variables on the mesoscale to macroscale are not generally affected by the choice of a cleaning technique. The long-term soiling pattern on the building is independent of the cleaning technique applied. This study also showed that soluble salts do not play a significant role in the deterioration of Berkshire Lee marble. Although salts were evident in cracks and fissures of the heavily soiled stone, such salts did not penetrate the surface to a depth of more than a few hundred micrometers. The criteria used to differentiate the cleaning techniques were ultimately based on the ability of each technique to remove soiling without altering the texture of the stone surface. This study identified both the gommage and JOS techniques as appropriate for cleaning ashlar surfaces and the combination technique as appropriate for cleaning highly carved surfaces at the entablatures, cornices, and column capitals.
NREL Analysis: Reimagining What's Possible for Clean Energy - Continuum
Analysis Helps Enable the Energy System of the Future NREL Helps Countries Build Stronger Economies with Low-Emission Development NREL Helps Countries Build Stronger Economies with Low-Emission Development
FIRST FLOOR, A view from the northeast corner of the ...
FIRST FLOOR, A view from the northeast corner of the clean room (Room 54) looking southwest - Department of Energy, Mound Facility, Isolated Building (I Building), One Mound Road, Miamisburg, Montgomery County, OH
Effectiveness of aged graffiti cleaning on granite by chemical and mechanical procedures
NASA Astrophysics Data System (ADS)
Gomes, Vera; Dionísio, Amélia; Santiago Pozo-Antonio, José
2017-04-01
Granite is one of the most common building stones in the European Cultural Heritage mainly in Northwest Iberian Peninsula. Nowadays, graffiti when a result of an act of vandalism is one of the most important threat, involving a serious risk to heritage sustainability. The cleaning is expensive and in most of the cases, the complete removal is not achieved. Many cities worldwide spend huge amounts of money in cleaning campaigns and European Commission started to create urban environment policies to prevent and eliminate graffiti and also finance projects to develop new cleaning procedures and antigraffiti coatings1,2. However, in many cases graffiti is applied in monuments and façades without antigraffiti and in real practice, they are only cleaned after being long exposure to the atmosphere, reaction with the environment (rain and atmospheric pollutants) and also with the substrate, leading changes in their physical and chemical properties. However, no scientific studies focused on graffiti aging were found and also on the influence of the aging on the cleaning effectiveness, which is always evaluated with fresh graffiti. Therefore, the need to optimize the cleaning of aged graffiti is urgent. This paper aims to study the influence of the exposition of graffiti paintings to one of the most important urban contaminant SO2 on the cleaning effectiveness of graffiti on the valuable ornamental granite Rosa Porriño. Two different chemical products and two different mechanical procedures based on low pressure projection (wet and dry) were evaluated. Four different colour graffiti paintings (red, black, blue and silver) with different compositions were tested. The criteria for assessing the global cleaning effectiveness was considering the graffiti extraction and also the damage induced on the substrate through changes in the chromatic parameters, static contact angle and surface roughness of the stones, identification of deleterious products and modification of the morphology and the composition of the surfaces. The previous characterization of the aged graffiti subjected to SO2 in an artificial chamber was also performed. After the evaluation of the global cleaning effectiveness, it was found that silver graffiti was the most sensitive painting to the aging under SO2 exposure and its higher deterioration degree hindered the cleaning, mainly with the chemical products. Also, the presence of neoformated minerals in the graffiti layers influenced the cleaning effectiveness achieved. Acknowledgements: This project is financed by Fundação Calouste Gulbenkian (Programa de Estímulo à Investigação). J.S. Pozo-Antonio was supported by a postdoctoral contract with the University of Vigowithin the framework of the 2011-2015 Galicia Plan for Research, Innovation and Growth (Plan I2C) for 2014. The authors also gratefully acknowledge the support of the CERENA (strategic project FCT-UID/ECI/04028/2013).
43 CFR 429.2 - What definitions are used in this part?
Code of Federal Regulations, 2011 CFR
2011-10-01
... the requirements of the National Environmental Policy Act; the Endangered Species Act; the Clean Water Act; the Clean Air Act; the Comprehensive Environmental Response, Compensation, and Liability Act... term includes, but is not limited to, buildings, canals, dams, ditches, drains, fish and wildlife...
Towards plasma cleaning of ITER first mirrors
NASA Astrophysics Data System (ADS)
Moser, L.; Marot, L.; Eren, B.; Steiner, R.; Mathys, D.; Leipold, F.; Reichle, R.; Meyer, E.
2015-06-01
To avoid reflectivity losses in ITER's optical diagnostic systems, on-site cleaning of metallic first mirrors via plasma sputtering is foreseen to remove deposit build-ups migrating from the main wall. In this work, the influence of aluminium and tungsten deposits on the reflectivity of molybdenum mirrors as well as the possibility to clean them with plasma exposure is investigated. Porous ITER-like deposits are grown to mimic the edge conditions expected in ITER, and a severe degradation in the specular reflectivity is observed as these deposits build up on the mirror surface. In addition, dense oxide films are produced for comparisons with porous films. The composition, morphology and crystal structure of several films were characterized by means of scanning electron microscopy, x-ray photoelectron spectroscopy, x-ray diffraction and secondary ion mass spectrometry. The cleaning of the deposits and the restoration of the mirrors' optical properties are possible either with a Kaufman source or radio frequency directly applied to the mirror (or radio frequency plasma generated directly around the mirror surface). Accelerating ions of an external plasma source through a direct current applied onto the mirror does not remove deposits composed of oxides. A possible implementation of plasma cleaning in ITER is addressed.
Project CLEAN: Safe, Sanitary School Restrooms. Fastback.
ERIC Educational Resources Information Center
Keating, Tom
After introducing the problem of unsafe, dirty public school restrooms, this publication describes Project CLEAN (Citizens, Learners, and Educators Against Neglect), an effort to improve the safety, cleanliness, and hygiene of student restrooms in public schools. The Project builds a five-step, school-by-school communication process that includes:…
7 CFR 51.56 - Buildings and structures.
Code of Federal Regulations, 2012 CFR
2012-01-01
... waste disposal and plumbing system maintained in good repair; (d) Each room in which the product is graded or stored shall be designed and constructed as to insure operating conditions of a clean and orderly character and shall be maintained in a clean and sanitary manner; and, (e) Every practical...
7 CFR 51.56 - Buildings and structures.
Code of Federal Regulations, 2011 CFR
2011-01-01
... waste disposal and plumbing system maintained in good repair; (d) Each room in which the product is graded or stored shall be designed and constructed as to insure operating conditions of a clean and orderly character and shall be maintained in a clean and sanitary manner; and, (e) Every practical...
Brandt, Mary; Brown, Clive; Burkhart, Joe; Burton, Nancy; Cox-Ganser, Jean; Damon, Scott; Falk, Henry; Fridkin, Scott; Garbe, Paul; McGeehin, Mike; Morgan, Juliette; Page, Elena; Rao, Carol; Redd, Stephen; Sinks, Tom; Trout, Douglas; Wallingford, Kenneth; Warnock, David; Weissman, David
2006-06-09
Extensive water damage after major hurricanes and floods increases the likelihood of mold contamination in buildings. This report provides information on how to limit exposure to mold and how to identify and prevent mold-related health effects. Where uncertainties in scientific knowledge exist, practical applications designed to be protective of a person's health are presented. Evidence is included about assessing exposure, clean-up and prevention, personal protective equipment, health effects, and public health strategies and recommendations. The recommendations assume that, in the aftermath of major hurricanes or floods, buildings wet for <48 hours will generally support visible and extensive mold growth and should be remediated, and excessive exposure to mold-contaminated materials can cause adverse health effects in susceptible persons regardless of the type of mold or the extent of contamination. For the majority of persons, undisturbed mold is not a substantial health hazard. Mold is a greater hazard for persons with conditions such as impaired host defenses or mold allergies. To prevent exposure that could result in adverse health effects from disturbed mold, persons should 1) avoid areas where mold contamination is obvious; 2) use environmental controls; 3) use personal protective equipment; and 4) keep hands, skin, and clothing clean and free from mold-contaminated dust. Clinical evaluation of suspected mold-related illness should follow conventional clinical guidelines. In addition, in the aftermath of extensive flooding, health-care providers should be watchful for unusual mold-related diseases. The development of a public health surveillance strategy among persons repopulating areas after extensive flooding is recommended to assess potential health effects and the effectiveness of prevention efforts. Such a surveillance program will help CDC and state and local public health officials refine the guidelines for exposure avoidance, personal protection, and clean-up and assist health departments to identify unrecognized hazards.
Performance of ultraviolet photocatalytic oxidation for indoor air cleaning applications.
Hodgson, A T; Destaillats, H; Sullivan, D P; Fisk, W J
2007-08-01
Ultraviolet photocatalytic oxidation (UVPCO) systems for removal of volatile organic compounds (VOCs) from air are being considered for use in office buildings. Here, we report an experimental evaluation of a UVPCO device with tungsten oxide modified titanium dioxide (TiO2) as the photocatalyst. The device was challenged with complex VOC mixtures. One mixture contained 27 VOCs characteristic of office buildings and another comprised 10 VOCs emitted by cleaning products, in both cases at realistic concentrations (low ppb range). VOC conversion efficiencies varied widely, usually exceeded 20%, and were as high as approximately 80% at about 0.03 s residence time. Conversion efficiency generally diminished with increased airflow rate, and followed the order: alcohols and glycol ethers > aldehydes, ketones, and terpene hydrocarbons > aromatic and alkane hydrocarbons > halogenated aliphatic hydrocarbons. Conversion efficiencies correlated with the Henry's law constant more closely than with other physicochemical parameters. An empirical model based on the Henry's law constant and the gas-phase reaction rate with hydroxyl radical provided reasonable estimates of pseudo-first order photocatalytic reaction rates. Formaldehyde, acetaldehyde, acetone, formic acid and acetic acid were produced by the device due to incomplete mineralization of common VOCs. Formaldehyde outlet/inlet concentration ratios were in the range 1.9-7.2. Implementation of air cleaning technologies for both VOCs and particles in office buildings may improve indoor air quality, or enable indoor air quality levels to be maintained with reduced outdoor air supply and concomitant energy savings. One promising air cleaning technology is ultraviolet photocatalytic oxidation (UVPCO) air cleaning. For the prototype device evaluated here with realistic mixtures of VOCs, conversion efficiencies typically exceeded the minimum required to counteract predicted VOC concentration increases from a 50% reduction in ventilation. However, the device resulted in the net generation of formaldehyde and acetaldehyde from the partial oxidation of ubiquitous VOCs. Further development of the technology is needed to eliminate these hazardous air pollutants before such a UVPCO device can be deployed in buildings.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-15
... and smart grid; and green building in residential, commercial and industrial settings. This mission....S. companies in the green building and energy efficiency subsectors. Companies will have the... building technologies and services. Greenbuilding/Energy Efficiency: Saudi Arabia is among the highest per...
4. Anode Building. View is to the east. This facility, ...
4. Anode Building. View is to the east. This facility, which was used for the cleaning and manufacture of anodes, was documented prior to demolition in 1993. - Sullivan Electrolytic Zinc Plant, Government Gulch, Kellogg, Shoshone County, ID
3 CFR 8757 - Proclamation 8757 of November 18, 2011. National Farm-City Week, 2011
Code of Federal Regulations, 2012 CFR
2012-01-01
... secure our clean energy future. During National Farm-City Week, we celebrate the essential contributions... energy future, my Administration is taking action to promote renewable energy production across rural America. As part of a comprehensive strategy to build our clean energy economy, we are working to produce...
A study was conducted during the summer of 1988 to document final cleaning procedures and evaluate Asbestos Hazard Emergency Response Act (AHERA) clearance air sampling practices used at 20 asbestos-abatement sites in New Jersey. Each abatement took place in a school building and...
76 FR 63527 - National Energy Action Month, 2011
Federal Register 2010, 2011, 2012, 2013, 2014
2011-10-12
... build a competitive 21st- century clean energy economy. Over the past two and a half years, my... us on track to doubling renewable energy capacity in the United States by the end of next year. At... to lead in clean energy is more intense than ever before. The United States cannot afford to fall...
15. DETAIL OF HEATSEALING DEVICE USED TO SEAL PLASTIC WRAPPING ...
15. DETAIL OF HEAT-SEALING DEVICE USED TO SEAL PLASTIC WRAPPING APPLIED TO CLEANED FAIRING ASSEMBLY. DEVICE LOCATED ON THE NORTH WALL OF CLEAN ROOM (102) NEAR DOOR TO ASSEMBLY ROOM (101). - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
2016-2020 Strategic Plan and Implementing Framework
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2015-11-01
The 2016-2020 Strategic Plan and Implementing Framework from the Office of Energy Efficiency and Renewable Energy (EERE) is the blueprint for launching the nation’s leadership in the global clean energy economy. This document will guide the organization to build on decades of progress in powering our nation from clean, affordable and secure energy.
7 CFR 51.56 - Buildings and structures.
Code of Federal Regulations, 2013 CFR
2013-01-01
... be an efficient waste disposal and plumbing system maintained in good repair; (d) Each room in which... a clean and orderly character and shall be maintained in a clean and sanitary manner; and, (e) Every practical precaution shall be taken to exclude dogs, cats, rodents and other vermin from the rooms in which...
7 CFR 51.56 - Buildings and structures.
Code of Federal Regulations, 2014 CFR
2014-01-01
... be an efficient waste disposal and plumbing system maintained in good repair; (d) Each room in which... a clean and orderly character and shall be maintained in a clean and sanitary manner; and, (e) Every practical precaution shall be taken to exclude dogs, cats, rodents and other vermin from the rooms in which...
46. CAPE COD AIR STATION PAVE PAWS FACILITY BUILDING ...
46. CAPE COD AIR STATION PAVE PAWS FACILITY - BUILDING ELEVATION VIEW WITH ALL METAL SIDING INSTALLED AND WITH EMITTER/ANTENNA ARRAY SYSTEM NEARING OCMPLETION ON "B" FACE (RIGHT). VIEW ALSO SHOWS TRAVELING "CLEANING" SYSTEM ON "B" FACE - NOW REMOVED. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
Harnessing natural ventilation benefits.
O'Leary, John
2013-04-01
Making sure that a healthcare establishment has a good supply of clean fresh air is an important factor in keeping patients, staff, and visitors, free from the negative effects of CO2 and other contaminants. John O'Leary of Trend Controls, a major international supplier of building energy management solutions (BEMS), examines the growing use of natural ventilation, and the health, energy-saving, and financial benefits, that it offers.
ERIC Educational Resources Information Center
Weidner, Robert H.
2003-01-01
Offers tips for fighting mold in schools, asserting that it can contribute significantly to poor indoor air quality and sick building syndrome. Offers an overview on mold and discusses the steps of: humidity control, building inspections, condensation control or removal, and floor and carpet cleaning. (EV)
[Control of disinfection in buildings used for poultry raising].
Maris, P
1989-01-01
During a 2-year survey in turkey breeding farms, it was possible to compare six disinfection procedures by monitoring 14 first disinfections following the breeding house cleaning and 14 second disinfections prior to animal return. By swabbing all the germs from asbestos concrete surfaces, we noted that in the case of first disinfection the chloramine T-based product was more effective than phenol or quaternary ammonium-aldehyde-based products. For the second disinfection, it was demonstrated that a minimal dose of 15 kg of formaldehyde was necessary for disinfection to be satisfactory; 12 to 15 kg paraformaldehyde was as effective as 40 to 60 liters of 30-35% formol for buildings, the ground surface of which covered between 1,000 and 1,300 m2.
Clean Energy Manufacturing Initiative Solid-State Lighting
Thomas, Sunil; Edmond, John; Krames, Michael; Rama
2018-05-30
The importance of U.S. manufacturing for clean energy technologies, such as solid-state lighting (SSL), is paramount to increasing competitiveness in a global marketplace. SSLs are poised to drive the lighting market, worldwide. In order to continue that competitiveness and support further innovation, the time to invest in U.S. manufacturing of clean energy technologies is now. Across the country, companies developing innovative clean energy technologies find competitive advantages to manufacturing in the U.S. The Department of Energy's Building Technology Office SSL Manufacturing Roadmap is just one example of how we support manufacturing through convening industry perspectives on opportunities to significantly reduce risk, improve quality, increase yields, and lower costs.
BDP Is Unified at the ATRF | Poster
By Ken Michaels, Staff Writer The Biopharmaceutical Development Program (BDP) at the Frederick National Laboratory is, for the first time ever, in a single building at the Advanced Technology Research Facility (ATRF). At Fort Detrick, BDP operations were spread out in about a dozen buildings, resulting in redundancies in maintaining various utilities (air handlers, clean steam, WFI, etc.) for multiple buildings rather than one.
EXTERIOR, A view looking northwest capturing disposal containers in the ...
EXTERIOR, A view looking northwest capturing disposal containers in the foreground. Also shown on the left side of the roof is the ventilation equipment used for the original clean room and on the right side the penthouse on the press building addition can be seen - Department of Energy, Mound Facility, Isolated Building (I Building), One Mound Road, Miamisburg, Montgomery County, OH
Veterans Advancing Clean Energy and Climate
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopser, Joseph; Marr, Andrea; Perez-Halperin, Elizabeth
2013-11-11
The Champions of Change series highlights ordinary Americans who are doing extraordinary things in their communities to out-innovate, out-educate and out-build the rest of the world. On November 5, 2013, the White House honored 12 veterans and leaders who are using the skills they learned in the armed services to advance the clean energy economy.
NREL Helps the National Park Service Celebrate Its Birthday with Clean
opportunities for renewable energy. This partnership aligns with NPS' Go Green initiative under their Call to Cities National Parks Initiative While much of NREL's work in national parks has focused on buildings and Cities collaborated with NPS to create the Clean Cities National Parks Initiative, which has resulted in
Veterans Advancing Clean Energy and Climate
Kopser, Joseph; Marr, Andrea; Perez-Halperin, Elizabeth; Eckstein, Robin; Moniz, Ernest
2018-01-16
The Champions of Change series highlights ordinary Americans who are doing extraordinary things in their communities to out-innovate, out-educate and out-build the rest of the world. On November 5, 2013, the White House honored 12 veterans and leaders who are using the skills they learned in the armed services to advance the clean energy economy.
A financing model to solve financial barriers for implementing green building projects.
Lee, Sanghyo; Lee, Baekrae; Kim, Juhyung; Kim, Jaejun
2013-01-01
Along with the growing interest in greenhouse gas reduction, the effect of greenhouse gas energy reduction from implementing green buildings is gaining attention. The government of the Republic of Korea has set green growth as its paradigm for national development, and there is a growing interest in energy saving for green buildings. However, green buildings may have financial barriers that have high initial construction costs and uncertainties about future project value. Under the circumstances, governmental support to attract private funding is necessary to implement green building projects. The objective of this study is to suggest a financing model for facilitating green building projects with a governmental guarantee based on Certified Emission Reduction (CER). In this model, the government provides a guarantee for the increased costs of a green building project in return for CER. And this study presents the validation of the model as well as feasibility for implementing green building project. In addition, the suggested model assumed governmental guarantees for the increased cost, but private guarantees seem to be feasible as well because of the promising value of the guarantee from CER. To do this, certification of Clean Development Mechanisms (CDMs) for green buildings must be obtained.
A Financing Model to Solve Financial Barriers for Implementing Green Building Projects
Lee, Baekrae; Kim, Juhyung; Kim, Jaejun
2013-01-01
Along with the growing interest in greenhouse gas reduction, the effect of greenhouse gas energy reduction from implementing green buildings is gaining attention. The government of the Republic of Korea has set green growth as its paradigm for national development, and there is a growing interest in energy saving for green buildings. However, green buildings may have financial barriers that have high initial construction costs and uncertainties about future project value. Under the circumstances, governmental support to attract private funding is necessary to implement green building projects. The objective of this study is to suggest a financing model for facilitating green building projects with a governmental guarantee based on Certified Emission Reduction (CER). In this model, the government provides a guarantee for the increased costs of a green building project in return for CER. And this study presents the validation of the model as well as feasibility for implementing green building project. In addition, the suggested model assumed governmental guarantees for the increased cost, but private guarantees seem to be feasible as well because of the promising value of the guarantee from CER. To do this, certification of Clean Development Mechanisms (CDMs) for green buildings must be obtained. PMID:24376379
6. FF coal pulverizer (ball mill inside). GG building in ...
6. FF coal pulverizer (ball mill inside). GG building in background did preliminary crushing; pulverizer to left, coal conveyor and air cleaning towers to right; conveyor on left brought crushed coal to FF. Looking north/northeast - Rouge Steel Company, 3001 Miller Road, Dearborn, MI
12. VIEW OF SPACE BETWEEN EAST FALSE PARTITION WALL IN ...
12. VIEW OF SPACE BETWEEN EAST FALSE PARTITION WALL IN CLEAN ROOM (102) AND EAST WALL OF VEHICLE SUPPORT BUILDING SHOWING PREFILTER NEAR SOUTH WALL - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
TA-60-1 Heavy Equipment Shop Areas SWPPP Rev 2 Jan 2017-Final
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burgin, Jillian Elizabeth
The primary activities and equipment areas at the facility that are potential stormwater pollution sources include; The storage of vehicles and heavy equipment awaiting repair; or repaired vehicles waiting to be picked up; The storage and handling of oils, anti-freeze, solvents, degreasers, batteries and other chemicals for the maintenance of vehicles and heavy equipment; and Equipment cleaning operations including exterior vehicle wash-down. Steam cleaning is only done on the steam cleaning pad area located at the north east end of Building 60-0001.
Clean Energy Manufacturing Initiative Solid-State Lighting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, Sunil; Edmond, John; Krames, Michael
2014-09-23
The importance of U.S. manufacturing for clean energy technologies, such as solid-state lighting (SSL), is paramount to increasing competitiveness in a global marketplace. SSLs are poised to drive the lighting market, worldwide. In order to continue that competitiveness and support further innovation, the time to invest in U.S. manufacturing of clean energy technologies is now. Across the country, companies developing innovative clean energy technologies find competitive advantages to manufacturing in the U.S. The Department of Energy's Building Technology Office SSL Manufacturing Roadmap is just one example of how we support manufacturing through convening industry perspectives on opportunities to significantly reducemore » risk, improve quality, increase yields, and lower costs.« less
Clean Energy Manufacturing Initiative Solid-State Lighting Video
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas, Sunil; Edmond, John; Krames, Michael
2014-09-23
The importance of U.S. manufacturing for clean energy technologies, such as solid-state lighting (SSL), is paramount to increasing competitiveness in a global marketplace. SSLs are poised to drive the lighting market, worldwide. In order to continue that competitiveness and support further innovation, the time to invest in U.S. manufacturing of clean energy technologies is now. Across the country, companies developing innovative clean energy technologies find competitive advantages to manufacturing in the U.S. The Department of Energy's Building Technology Office SSL Manufacturing Roadmap is just one example of how we support manufacturing through convening industry perspectives on opportunities to significantly reducemore » risk, improve quality, increase yields, and lower costs.« less
US Clean Energy Sector and the Opportunity for Modeling and Simulation
NASA Technical Reports Server (NTRS)
Inge, Carole Cameron
2011-01-01
The following paper sets forth the current understanding of the US clean energy demand and opportunity. As clean energy systems come online and technology is developed, modeling and simulation of these complex energy programs provides an untapped business opportunity. The US Department of Defense provides a great venue for developing new technology in the energy sector because it is demanding lower fuel costs, more energy efficiencies in its buildings and bases, and overall improvements in its carbon footprint. These issues coupled with the security issues faced by foreign dependence on oil will soon bring more clean energy innovations to the forefront (lighter batteries for soldiers, alternative fuel for jets, energy storage systems for ships, etc).
Clean Energy Manufacturing Initiative Solid-State Lighting Video
Thomas, Sunil; Edmond, John; Krames, Michael; Raman, Sudhakar
2018-01-16
The importance of U.S. manufacturing for clean energy technologies, such as solid-state lighting (SSL), is paramount to increasing competitiveness in a global marketplace. SSLs are poised to drive the lighting market, worldwide. In order to continue that competitiveness and support further innovation, the time to invest in U.S. manufacturing of clean energy technologies is now. Across the country, companies developing innovative clean energy technologies find competitive advantages to manufacturing in the U.S. The Department of Energy's Building Technology Office SSL Manufacturing Roadmap is just one example of how we support manufacturing through convening industry perspectives on opportunities to significantly reduce risk, improve quality, increase yields, and lower costs.
The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems
NASA Astrophysics Data System (ADS)
Wilson, Eric J. H.
2011-12-01
This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both heating and cooling energy, and ranges from 7% in Los Angeles, CA to 13% in Fairbanks, AK. These results assume a leaky and uninsulated duct system. The potential for savings from cleaning decreases if duct insulation is in place or sealing has been performed. The potential for energy savings is directly related to the distribution system's thermal efficiency, with air conditioner performance also playing a minor role. Results for small commercial buildings with constant air volume HVAC systems and leaky and uninsulated duct systems span a wider range: from -12% in Miami, FL to 30% in Minneapolis, MN. However, for improved ducts or ducts in the conditioned space, small commercial HVAC source energy savings is always negative (down to -17%) for flowrates degradation in the 0--40% range. The sensitivity of these results to duct characteristics (location, leakage, and insulation) and the after-cleaning flowrate, as it varies from an ideal flowrate, was also evaluated. Energy savings can reach up to 80% for some scenarios where clean airflow is severely restricted down to 20% of ideal by poor duct layout or other obstructions not removable by cleaning. In addition, a simplified spreadsheet tool was developed for technicians to use in the field to estimate potential savings resulting from a system cleaning. Measuring the temperature rise across the furnace was found to give less uncertainty than measuring the pressure rise and assuming a fan curve. Despite the uncertainty, the tool can give a general idea of the range of savings possible under various conditions.
The effect of house design and environment on fungal movement in homes of bronchial asthma patients.
Takatori, K; Saito, A; Yasueda, H; Akiyama, K
2001-01-01
The effect of house building design and environment on the fungal movement in the houses of 41 bronchial asthma (BA) patients has been investigated by examining house dust. The presence and composition of fungi were determined and compared in relation to building structure, house age, size of living room, main flooring material, presence of a living-room rug or air purifier, and frequency of vacuum cleaning. Among these elements, fungal CFU apparently varied only between building structure: wooden-board houses had significantly higher numbers of fungi than reinforced concrete houses (p < 0.01), and wooden mortar or iron-framed prefabricated houses had significantly higher numbers of fungi than reinforced concrete houses (p < 0.05). Classification of the types of fungi present in the house dust of BA patients showed that, regardless of the building designs, there were high levels of osmophilic fungi (group A) and fungi that survive at relatively dry conditions (group B), whereas fungi that survive in very wet conditions (group D) were present at low frequency.
Viability of fungal and actinomycetal spores after microwave radiation of building materials.
Górny, Rafał L; Mainelis, Gediminas; Wlazło, Agnieszka; Niesler, Anna; Lis, Danuta O; Marzec, Stanisław; Siwińska, Ewa; Łudzeń-Izbińska, Beata; Harkawy, Aleksander; Kasznia-Kocot, Joanna
2007-01-01
The effects of microwave radiation on viability of fungal and actinomycetal spores growing on agar (medium optimal for growth) as well as on wooden panel and drywall (common building construction/finishing materials) were studied. All materials were incubated at high (97-99%) and low (32-33%) relative humidity to mimic "wet" and "dry" environmental conditions. Two microwave power densities (10 and 60 mW/cm2) and three times of exposure (5, 30, and 60 min) were tested to find the most effective parameters of radiation which could be applied to non-invasive reduction or cleaning of building materials from microbial contaminants. Additionally, a control of the surface temperature during the experiments allowed differentiation between thermal and microwave effect of such radiation. The results showed that the viability of studied microorganisms differed depending on their strains, growth conditions, power density of microwave radiation, time of exposure, and varied according to the applied combination of the two latter elements. The effect of radiation resulting in a decrease of spore viability on "wet" wooden panel and drywall was generally observed at 60 min exposure. Shorter exposure times decreased the viability of fungal spores only, while in actinomycetes colonizing the studied building materials, such radiation caused an opposite (supporting growth) effect.
NASA Clean-Sheet Fans: Design, Build Analyze, Test, and Report
NASA Technical Reports Server (NTRS)
Koch, L. Danielle
2008-01-01
A suggested topic in small fan research is presented. Presentation briefly describes the scope of an effort to design, build and test a ventilation class cooling fan. Comments are included for the following categories: information (available and needed), benefits and values, concerns, variations and alternatives, and interest.
ERIC Educational Resources Information Center
Smith, Dwight; And Others
This instructional package is one of two designed for regular vocational students in the vocational area of building maintenance and engineering. The fifty-three learning modules are organized into ten units: office cleaning; grounds; sanitation; boiler maintenance and operation; power and hand tools; cabinet construction; repair of damaged…
Clean Energy Infrastructure Educational Initiative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hallinan, Kevin; Menart, James; Gilbert, Robert
2012-08-31
The Clean Energy Infrastructure Educational Initiative represents a collaborative effort by the University of Dayton, Wright State University and Sinclair Community College. This effort above all aimed to establish energy related programs at each of the universities while also providing outreach to the local, state-wide, and national communities. At the University of Dayton, the grant has aimed at: solidfying a newly created Master's program in Renewable and Clean Energy; helping to establish and staff a regional sustainability organization for SW Ohio. As well, as the prime grantee, the University of Dayton was responsible for insuring curricular sharing between WSU andmore » the University of Dayton. Finally, the grant, through its support of graduate students, and through cooperation with the largest utilities in SW Ohio enabled a region-wide evaluation of over 10,000 commercial building buildings in order to identify the priority buildings in the region for energy reduction. In each, the grant has achieved success. The main focus of Wright State was to continue the development of graduate education in renewable and clean energy. Wright State has done this in a number of ways. First and foremost this was done by continuing the development of the new Renewable and Clean Energy Master's Degree program at Wright State . Development tasks included: continuing development of courses for the Renewable and Clean Energy Master's Degree, increasing the student enrollment, and increasing renewable and clean energy research work. The grant has enabled development and/or improvement of 7 courses. Collectively, the University of Dayton and WSU offer perhaps the most comprehensive list of courses in the renewable and clean energy area in the country. Because of this development, enrollment at WSU has increased from 4 students to 23. Secondly, the grant has helped to support student research aimed in the renewable and clean energy program. The grant helped to solidify new research in the renewable and clean energy area. The educational outreach provided as a result of the grant included activities to introduce renewable and clean energy design projects into the Mechanical and Materials Engineering senior design class, the development of a geothermal energy demonstration unit, and the development of renewable energy learning modules for high school students. Finally, this grant supported curriculum development by Sinclair Community College for seven new courses and acquisition of necessary related instrumentation and laboratory equipment. These new courses, EGV 1201 Weatherization Training, EGV 1251 Introduction to Energy Management Principles, EGV 2301 Commercial and Industrial Assessment, EGV 2351 LEED Green Associate Exam Preparation, EGV 2251 Energy Control Strategies, EGV Solar Photovoltaic Design and Installation, and EGV Solar Thermal Systems, enable Sinclair to offer complete Energy Technology Certificate and an Energy Management Degree programs. To date, 151 students have completed or are currently registered in one of the seven courses developed through this grant. With the increasing interest in the Energy Management Degree program, Sinclair has begun the procedure to have the program approved by the Ohio Board of Regents.« less
Cui, Linfan; Zhang, Panpan; Xiao, Yukun; Liang, Yuan; Liang, Hanxue; Cheng, Zhihua; Qu, Liangti
2018-05-01
The use of abundant solar energy for regeneration and desalination of water is a promising strategy to address the challenge of a global shortage of clean water. Progress has been made to develop photothermal materials to improve the solar steam generation performance. However, the mass production rate of water is still low. Herein, by a rational combination of photo-electro-thermal effect on an all-graphene hybrid architecture, solar energy can not only be absorbed fully and transferred into heat, but also converted into electric power to further heat up the graphene skeleton frame for a much enhanced generation of water vapor. As a result, the unique graphene evaporator reaches a record high water production rate of 2.01-2.61 kg m -2 h -1 under solar illumination of 1 kW m -2 even without system optimization. Several square meters of the graphene evaporators will provide a daily water supply that is enough for tens of people. The combination of photo-electro-thermal effect on graphene materials offers a new strategy to build a fast and scalable solar steam generation system, which makes an important step towards a solution for the scarcity of clean water. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
NASA Astrophysics Data System (ADS)
Ledley, T. S.; Niepold, F., III; Bozuwa, J.; Davis, A.; Fraser, J.; Kretser, J.; Poppleton, K. L. I.; Qusba, L.; Ruggiero, K.; Spitzer, W.; Stylinski, C.
2016-12-01
The Climate Literacy and Energy Awareness Network (CLEAN) was formed in 2008 to help climate and energy literacy stakeholders implement the Climate and Energy Literacy Essential Principles to enable effective and responsible decisions with regard to actions that may affect climate. The ongoing conversations of the CLEAN Network have cultivated a culture of shared resources and expertise and allowed for the development of collective impact strategies. However, it has become clear that to accelerate and scale change, effective mitigation, adaptation, and resilience strategies must be developed by a diverse network of stakeholders at the community level to deal with the local impacts of climate change and move toward decarbonized and resilient economies. A group of CLEAN Network members, experienced in establishing effective networks and representing mature climate change education programs, came together to discuss at the community level 1) how we can collectively enable larger scale efforts to 2) develop effective strategies, 3) identify gaps in the system that limit action, and 4) coordinate possible vectors for interceding to advance community level decisions related to climate. We will describe our Theory of Change, based on both the power of communities and increasing climate literacy as a key requirement for sustained progress on the crisis climate change presents. From our Theory of Change, we have begun to outline a national monitoring strategy that can provide communities a measured way to understand their local readiness to respond to the impacts of climate change and understand the magnitude of those impacts in relation to their political and ecological economies. The scale would help describe the robustness of their programs and partnerships to address those impacts, the political climate for working in advance of pending change, and the degree of citizen engagement in resilience planning and action. The goal is to provide a common tool equivalent to GDP that communities could use to see their strengths and leverage points, and where they have the local resources to build solutions or co-develop solutions with others. Though this new tool, communities may be better able to focus on mitigation, adaptation, and the building of resilience that will put into practice the identified Theory of Change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harvey, T.N.
The Global Environmental Technology Enterprise (GETE) was conceived to develop and implement strategies to facilitate the commercialization of innovative, cost-effective Department of Energy (DOE)-developed environmental technologies. These strategies are needed to aid DOE`s clean-up mission; to break down barriers to commercialization; and to build partnerships between the federal government and private industry in order to facilitate the development and use of innovative environmental technologies.
Clean Cities: Building Partnerships to Cut Petroleum Use in Transportation
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2016-01-07
This brochure provides an overview of the U.S. Department of Energy's (DOE's) Clean Cities program, which advances the nation's economic, environmental, and energy security by supporting local actions to cut petroleum use in transportation. At the national level, the program develops and promotes publications, tools, and other unique resources. At the local level, nearly 100 coalitions leverage these resources to create networks of stakeholders.
Clean Cities: Building Partnerships to Cut Petroleum Use in Transportation
DOE Office of Scientific and Technical Information (OSTI.GOV)
2016-01-01
This brochure provides an overview of the U.S. Department of Energy's (DOE's) Clean Cities program, which advances the nation's economic, environmental, and energy security by supporting local actions to cut petroleum use in transportation. At the national level, the program develops and promotes publications, tools, and other unique resources. At the local level, nearly 100 coalitions leverage these resources to create networks of stakeholders.
BDP Is Unified at the ATRF | Poster
By Ken Michaels, Staff Writer The Biopharmaceutical Development Program (BDP) at the Frederick National Laboratory is, for the first time ever, in a single building at the Advanced Technology Research Facility (ATRF). At Fort Detrick, BDP operations were spread out in about a dozen buildings, resulting in redundancies in maintaining various utilities (air handlers, clean
5. Historic American Buildings Survey, N.E. Baldwin, Photographer, November 1939, ...
5. Historic American Buildings Survey, N.E. Baldwin, Photographer, November 1939, INTERIOR: WITH CLOTHES PRESS DOOR, CHIMNEY CLOSETS AND CHIMNEY CLEAN-OUT, AND BUILT-IN CHEST OF DRAWERS, Gift of New York State Department of Education. - Shaker West Family Main Dwelling House, Watervliet Shaker Road, Colonie Township, Watervliet, Albany County, NY
Multiple Learning Strategies Project. Building Maintenance & Engineering. Low Reader. [Vol. 2.
ERIC Educational Resources Information Center
Steinberg, A.; And Others
This instructional package is one of two designed for low reader students (those reading at grade level 3-6) in the vocational area of building maintenance and engineering. The forty-four learning modules are organized into eleven units: chalkboards; carpet care; office cleaning; grounds; sanitation; boiler maintenance and operation; power and…
Sokaogon Chippewa Community Emission-Free and Treaty Resource Protection Clean Energy Initiative
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quade, Ron
Final Report for DOE project DE-IE0000036 The Sokaogon Chippewa Community received a tribal clean energy initiative grant and installed a community wide solar system estimated to produce 606 kw of carbon free clean energy on seventeen (17) tribal buildings and three (3) residential homes significantly reducing the tribes’ energy bills over the life of the system, potentially saving the tribe up to $2.7 million in energy savings over a thirty (30) year time span. Fifteen (15) solar installations utilized aluminum roof-top mounting systems while two (2) installations utilized a ground mount aluminum racking system.
Wei, W; Boumier, J; Wyart, G; Ramalho, O; Mandin, C
2016-08-01
In the framework of a nationwide survey on indoor air quality conducted from September 2009 to June 2011 in 310 nurseries, kindergartens, and elementary schools in all regions of France, cleaning practices and products were described through an extensive questionnaire completed on-site by expert building inspectors. The questionnaire included the cleaning frequencies and periods, cleaning techniques, whether windows were open during cleaning, and the commercial names of the products used. Analysis of the questionnaire responses showed that cleaning was generally performed daily for furniture and floors. It was performed mostly in the evening with wet mopping and with one or more windows open. Five hundred eighty-four different cleaning products were listed, among which 218 safety data sheets (SDSs) were available and analyzed. One hundred fifty-two chemical substances were identified in the SDSs. The typical substances in cleaning products included alcohols, chlorides, terpenes, aldehydes, and ethers; more than half of them are irritants. Two endocrine disruptors, 2-phenylphenol and Galaxolide, were identified in two cleaning products used every day to clean the floors, in seven kindergartens and in a nursery respectively. Eleven reactive substances containing C=C double bonds, mostly terpenes, were identified in a wide variety of cleaning products. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Stackhouse, P. W., Jr.; Ganoe, R. E.; Westberg, D. J.; Leng, G. J.; Teets, E.; Hughes, J. M.; De Young, R.; Carroll, M.; Liou, L. C.; Iraci, L. T.; Podolske, J. R.; Stefanov, W. L.; Chandler, W.
2016-12-01
The NASA Climate Adaptation Science Investigator team is devoted to building linkages between NASA Earth Science and those within NASA responsible for infrastructure assessment, upgrades and planning. One of the focus areas is assessing NASA center infrastructure for energy efficiency, planning to meet new energy portfolio standards, and assessing future energy needs. These topics intersect at the provision of current and predicted future weather and climate data. This presentation provides an overview of the multi-center effort to access current building energy usage using Earth science observations, including those from in situ measurements, satellite measurement analysis, and global model data products as inputs to the RETScreen Expert, a clean energy decision support tool. RETScreen® Expert, sponsored by Natural Resources Canada (NRCan), is a tool dedicated to developing and providing clean energy project analysis software for the feasibility design and assessment of a wide range of building projects that incorporate renewable energy technologies. RETScreen Expert requires daily average meteorological and solar parameters that are available within less than a month of real-time. A special temporal collection of meteorological parameters was compiled from near-by surface in situ measurements. These together with NASA data from the NASA CERES (Clouds and Earth's Radiance Energy System)/FLASHFlux (Fast Longwave and SHortwave radiative Fluxes) provides solar fluxes and the NASA GMAO (Global Modeling and Assimilation Office) GEOS (Goddard Earth Observing System) operational meteorological analysis are directly used for meteorological input parameters. Examples of energy analysis for a few select buildings at various NASA centers are presented in terms of the energy usage relationship that these buildings have with changes in their meteorological environment. The energy requirements of potential future climates are then surveyed for a range of changes using the most recent CMIP5 global climate model data output.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael G.; Apte, Joshua S.
2010-04-27
The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rankmore » among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in the building. The plants used in the rooftop greenhouse and on the floors were made up of a number of species selected for the following functions: daytime metabolic carbon dioxide (CO{sub 2}) absorption, nighttime metabolic CO{sub 2} absorption, and volatile organic compound (VOC) and inorganic gas absorption/removal for air cleaning. The building contains a reported 910 indoor plants. Daytime metabolic species reported by the PBC include Areca Palm, Oxycardium, Rubber Plant, and Ficus alii totaling 188 plants (21%). The single nighttime metabolic species is the Sansevieria with a total of 28 plants (3%). The 'air cleaning' plant species reported by the PBC include the Money Plant, Aglaonema, Dracaena Warneckii, Bamboo Palm, and Raphis Palm with a total of 694 plants (76%). The plants in the greenhouse (Areca Palm, Rubber Plant, Ficus alii, Bamboo Palm, and Raphis Palm) numbering 161 (18%) of those in the building are grown hydroponically, with the room air blown by fan across the plant root zones. The plants on the building floors are grown in pots and are located on floors 1-6. We conducted a one-day monitoring session in the PBC on January 1, 2010. The date of the study was based on availability of the measurement equipment that the researchers had shipped from Lawrence Berkeley National Lab in the U.S.A. The study date was not optimal because a large proportion of the regular building occupants were not present being New Year's Day. An estimated 40 people were present in the building all day during January 1. This being said, the building systems were in normal operations, including the air handlers and other HVAC components. The study was focused primarily on measurements in the Greenhouse and 3rd and 5th floor environments as well as rooftop outdoors. Measurements included a set of volatile organic compounds (VOCs) and aldehydes, with a more limited set of observations of indoor and outdoor particulate and carbon dioxide concentrations. Continuous measurements of Temperature (T) and relative humidity (RH) were made selected indoor and outdoor locations.« less
A mechanistic study of limonene oxidation products and pathways following cleaning activities
NASA Astrophysics Data System (ADS)
Carslaw, Nicola
2013-12-01
Indoor air pollution has caused increasing concern since the 1970s, when the advent of stricter energy efficiency measures lead to increased reports of building related symptoms. Cleaning activities have been linked to adverse health effects indoors, although it is unclear which of the components of cleaning products cause these reported health effects. This paper uses a detailed chemical model for indoor air chemistry, to identify the species formed at the highest concentrations following use of a limonene-based cleaning product. The explicit nature of the chemical mechanism also permits the key pathways to their formation to be identified. The results show that the key species in terms of gas-phase concentration are multi-functional carbonyl species including limonaldehyde, 4-acetyl-1-methyl-1-cyclohexene and other dicarbonyl species. The particle-phase was dominated by peroxide species. The predicted gas-phase concentrations for three limonene-oxidation products were compared to recently published human reference values, but found not to be high enough to cause concern for typical indoor conditions, or under high indoor ozone conditions. However, cleaning products contain a range of terpenes other than limonene, which could also produce some of the secondary products identified here, as well as more common species such as formaldehyde, glyoxal and hydrogen peroxide. A mechanistic pathway analysis shows that the secondary products formed through limonene oxidation indoors depend critically on the competition between ozone and hydroxyl radicals, such that indoor pollutant concentrations and composition could vary widely in different locations for a nominally similar residence and indoor activities. Future studies should focus on aiming to measure multi-functional carbonyl species indoors to help validate models, whilst human reference values are needed for many more relevant species indoors.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Haidar, S.; Rylance, M.; Tybero, G.
1996-12-31
Having completed both fracture treatments as discussed in a companion paper, this paper continues on to describe the post fracture shut-in, clean-up and well testing operations that took place on the Viking Wx exploration well 49/17-12. These operations involved the removal of Resin Coated Proppant (RCP) from the wellbore, via Coiled Tubing (CT), through the use of a specially designed jetting nozzle. The RCP pack stability at a concentration of 3.0 lb/ft{sup 2} (as per planned design) had already been tested in a flowback cell. The use of a Surface Read-Out (SRO) gauge, combined with gas, water and proppant flowmore » rates as well as the viscosity of fracturing fluids returns, enabled real time calculation of the drag forces, on the proppant pack, during clean-up. The flow rate, in the field, was controlled such that the calculated drag forces remained below those observed in the laboratory. Following the clean-up a flow and build-up test was conducted, to evaluate the fracture half length and fracture conductivity, from which a Pseudo-radial skin was calculated. The Non-Darcy effects in the fracture were also evaluated, and finally the short term and long term well deliverabilities were assessed.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mattlin, E.; Charboneau, S.; Johnston, G.
2007-07-01
The 241-Z treatment and storage tanks, a hazardous waste Treatment, Storage and Disposal (TSD) unit permitted pursuant to the Resource Conservation and Recovery Act of 1976 (RCRA) and Washington State Hazardous Waste Management Act, RCW 70.105, , have been deactivated and are being actively decommissioned under the provisions of the Hanford Federal Facility Agreement and Consent Order (HFFACO), RCRA and Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) 42 U.S.C. 9601 et seq. The 241-Z TSD unit managed non-listed radioactive contaminated waste water, containing trace RCRA characteristic constituents. The 241-Z TSD unit consists of below grade tanks (D-4,more » D-5, D-7, D-8, and an overflow tank) located in a concrete containment vault, sample glovebox GB-2-241-ZA, and associated ancillary piping and equipment. The tank system is located beneath the 241-Z building. The 241-Z building is not a portion of the TSD unit. The sample glovebox is housed in the above-grade building. Waste managed at the TSD unit was received via underground piping from Plutonium Finishing Plant (PFP) sources. Tank D-6, located in the D-6 vault cell, is a past-practice tank that was taken out of service in 1972 and has never operated as a portion of the RCRA TSD unit. CERCLA actions will address Tank D-6, its containment vault cell, and soil beneath the cell that was potentially contaminated during past-practice operations and any other potential past-practice contamination identified during 241-Z closure, while outside the scope of the Hanford Facility Dangerous Waste Closure Plan, 241-Z Treatment and Storage Tanks. Under the RCRA closure plan, the 241-Z TSD unit is anticipated to undergo clean closure to the performance standards of the State of Washington with respect to dangerous waste contamination from RCRA operations. The TSD unit will be clean closed if physical closure activities identified in the plan achieve clean closure standards for all 241-Z locations. Clean closed 241-Z treatment and storage tanks, equipment and/or structures will remain after RCRA clean closure for future disposition in conjunction with PFP decommissioning activities which are integrated with CERCLA. (authors)« less
Energy storage deployment and innovation for the clean energy transition
NASA Astrophysics Data System (ADS)
Kittner, Noah; Lill, Felix; Kammen, Daniel M.
2017-09-01
The clean energy transition requires a co-evolution of innovation, investment, and deployment strategies for emerging energy storage technologies. A deeply decarbonized energy system research platform needs materials science advances in battery technology to overcome the intermittency challenges of wind and solar electricity. Simultaneously, policies designed to build market growth and innovation in battery storage may complement cost reductions across a suite of clean energy technologies. Further integration of R&D and deployment of new storage technologies paves a clear route toward cost-effective low-carbon electricity. Here we analyse deployment and innovation using a two-factor model that integrates the value of investment in materials innovation and technology deployment over time from an empirical dataset covering battery storage technology. Complementary advances in battery storage are of utmost importance to decarbonization alongside improvements in renewable electricity sources. We find and chart a viable path to dispatchable US$1 W-1 solar with US$100 kWh-1 battery storage that enables combinations of solar, wind, and storage to compete directly with fossil-based electricity options.
76 FR 26336 - Notice of Request for Approval of an Information Collection
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-06
.... 5308--Clean Fuels Grant Program. DATES: Comments must be submitted before July 5, 2011. ADDRESSES: To...., Docket Operations, M-30, West Building, Ground Floor, Room W12- 140, Washington, DC 20590-0001. 4. Hand... Building, Ground Floor, Room W12-140, Washington, DC 20590-0001 between 9 a.m. and 5 p.m., Monday through...
ALF: a facility for x-ray lithography II--a progress report
NASA Astrophysics Data System (ADS)
Lesoine, L. G.; Kukkonen, Kenneth W.; Leavey, Jeffrey A.
1992-07-01
In our previous paper which we presented here two years ago, we described the ALF (Advanced Lithography Facility), IBM's new facility for X-ray lithography which was built as an addition to the Advanced Semiconductor Technology Center at IBM's semiconductor plant in Hopewell Jct., NY. At that time, we described the structure, its utilities, facilities and special features such as the radiation shielding, control room, clean room and vibration resistant design. The building has been completed and occupied. By the time this paper is presented the storage ring will be commissioned, the clean room occupied, and two beamlines with one stepper operational. In this paper we will review the successful completion of the facility with its associated hardware. The installation of the synchrotron will be described elsewhere. We will also discuss the first measurements of vibration, clean room cleanliness and the effectiveness of the radiation shielding. The ALF was completed on schedule and cost objectives were met. This is attributed to careful planning, close cooperation among all the parties involved from the technical team in IBM Research, the system vendor (Oxford Instruments of Oxford England) to the many contractors and subcontractors and to strong support from IBM senior management. All the planned building specifications were met and the facility has come on-line with a minimum of problems. Most important, the initial measurements show that the radiation shielding plan is sound and that with a few modifications the dose limit of 10% of background will be met. Any concerns about an electron accelerator and synchrotron in an industrial setting have been eliminated.
40 CFR 61.144 - Standard for manufacturing.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., twine, rope, thread, yarn, roving, lap, or other textile materials. (2) The manufacture of cement... manufacturing facility, including air cleaning devices, process equipment, and buildings housing material...
40 CFR 61.144 - Standard for manufacturing.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., twine, rope, thread, yarn, roving, lap, or other textile materials. (2) The manufacture of cement... manufacturing facility, including air cleaning devices, process equipment, and buildings housing material...
40 CFR 61.144 - Standard for manufacturing.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., twine, rope, thread, yarn, roving, lap, or other textile materials. (2) The manufacture of cement... manufacturing facility, including air cleaning devices, process equipment, and buildings housing material...
40 CFR 61.144 - Standard for manufacturing.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., twine, rope, thread, yarn, roving, lap, or other textile materials. (2) The manufacture of cement... manufacturing facility, including air cleaning devices, process equipment, and buildings housing material...
40 CFR 61.144 - Standard for manufacturing.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., twine, rope, thread, yarn, roving, lap, or other textile materials. (2) The manufacture of cement... manufacturing facility, including air cleaning devices, process equipment, and buildings housing material...
NASA Astrophysics Data System (ADS)
Gold, A. U.; Sullivan, S. M.; Manning, C. L. B.; Ledley, T. S.; Youngman, E.; Taylor, J.; Niepold, F., III; Kirk, K.; Lockwood, J.; Bruckner, M. Z.; Fox, S.
2017-12-01
The impacts of climate change are a critical societal challenge of the 21st century. Educating students about the globally connected climate system is key in supporting the development of mitigation and adaptation strategies. Systems thinking is required for students to understand the complex, dynamic climate systems and the role that humans play within them. The interdisciplinary nature of climate science challenges educators, who often don't have formal training in climate science, to identify resources that are scientifically accurate before weaving them together into units that teach about the climate system. The Climate Literacy and Energy Awareness Network (CLEAN) supports this work by providing over 700 peer-reviewed, classroom-ready resources on climate and energy topics. The resource collection itself provide only limited instructional guidance, so educators need to weave the resources together to build multi-dimensional lessons that develop systems thinking skills. The Next Generation Science Standards (NGSS) science standards encourage educators to teach science in a 3-dimensional approach that trains students in systems thinking. The CLEAN project strives to help educators design NGSS-style, three-dimensional lessons about the climate system. Two approaches are currently being modeled on the CLEAN web portal. The first is described in the CLEAN NGSS "Get Started Guide" which follows a step-by-step process starting with the Disciplinary Core Idea and then interweaves the Cross-Cutting Concepts (CCC) and the Science and Engineering Practices (SEP) based on the teaching strategy chosen for the lesson or unit topic. The second model uses a climate topic as a starting place and the SEP as the guide through a four-step lesson sequence called "Earth Systems Investigations". Both models use CLEAN reviewed lessons as the core activity but provide the necessary framework for classroom implementation. Sample lessons that were developed following these two approaches are provided on the CLEAN web portal (cleanet.org).
Development of gypsum alteration on marble and limestone
McGee, E.S.
1996-01-01
Blackened alteration crusts of gypsum plus particulates that form on sheltered areas on marble and limestone buildings pose a challenge for rehabilitation and cleaning. Fresh marble and limestone samples exposed at monitored exposure sites present conditions of simple geometry and well-documented exposures but have short exposure histories (one to five years). The gypsum alteration crusts that develop on these samples provide insight into the early stages and rate of alteration crust formation. Alteration crusts from buildings give a longer, but less well known exposure history and present much more complex surfaces for gypsum accumulation. Integrated observations and measurements of alteration crusts from exposure samples and from buildings identify four factors that are important in the formation and development of alteration crusts on marble and limestone: (1) pollution levels, (2) exposure to rain or washing, (3) geometry of exposure of the stone surface, and (4) permeability of the stone. The combination of these factors contributes to both the distribution and the physical characteristics of the gypsum crusts which may affect cleaning decisions.
Shahraki, GholamHossein; Bin Ibrahim, Yusof; Noor, Hafidzi Mohd; Rafinejad, Javad; Shahar, Mohd Khadri
2010-08-01
This study assessed the effectiveness of a biorational control approach using 2% hydramethylnon gel bait on German cockroaches, Blattella germanica (L.) in some residential and hospital buildings in South Western Iran. In total, three buildings consisting of 150 apartment units and 101 hospital units were monitored weekly via sticky trap for German cockroach infestations over a period of eight months. These infested units were randomly subjected to intervention and control treatments. Pamphlets and posters were provided and lectures were given to support the educational programmes as a tactic of the biorational system. Survey on cockroach index for intervention units showed 67-94% recovery to achieve clean level of infestation for intervention units of the residential buildings and 83% for the hospital. Mean percentage reductions for treatment groups throughout the 15-week treatment period were 76.8% for the residential buildings and 88.1% for the hospital, showing significant differences compared to the control groups. Linear regression of infestation rates were recorded weekly after treatment and their negative slope for treatment groups substantiated significant reductions for interventions. The results of this study showed that biorational control method, using gel bait, educational programmes and sanitation, is an effective way to manage German cockroach infestation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Verce, M F; Jayaraman, B; Ford, T D
2007-09-07
This work examined the behavior of vaporous hydrogen peroxide (VHP) in clean, room-scale galvanized steel (GS) and polyvinylchloride-coated steel air ducts, to understand how it might be used to decontaminate larger ventilation systems. VHP injected into the GS duct decreased in concentration along the length of the duct, whereas VHP concentrations in the polyvinylchloride coated duct remained essentially constant, suggesting that VHP decomposed at the GS surface. However, decomposition was reduced at lower temperatures ({approx} 22 C) and higher flow rates ({approx} 80 actual cubic meter per hour). A computational fluid dynamics model incorporating reactive transport was used to estimatemore » surface VHP concentrations where contamination is likely to reside, and also showed how bends encourage VHP decomposition. Use of G. stearothermophilus indicators, in conjunction with model estimates, indicated that a concentration-contact time of {approx} 100 mg/L H{sub 2}O{sub 2}(g){center_dot}min was required to achieve a 6 log reduction of indicator spores in clean GS duct, at 30 C. When VHP is selected for building decontamination, this work suggests the most efficacious strategy may be to decontaminate GS ducting separately from the rest of the building, as opposed to a single decontamination event in which the ventilation system is used to distribute VHP throughout the entire building.« less
Building Toxic Metal Characterization and Decontamination Report: Area 6, Building 914
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Industrial Hygiene
2011-08-15
The purpose of this report is to outline the toxic metal characterization and decontamination efforts in Area 6, Building 914. This includes the initial building inspection, the hotspot sampling, results/findings, building cleanup, and the verification sampling. Building 914 is a steel light frame building that was constructed in 1992. It is about 16,454 square feet, and five employees are assigned to this building. According to the building's floor plan blueprints, it could be inferred that this building was once a Wiremen/Lineman shop. In 2002-2004, the National Nuclear Security Administration Nevada Site Office embarked on a broad characterization of beryllium (Be)more » surface concentrations throughout the North Las Vegas Facility, the Nevada National Security Site (NNSS), and ancillary facilities like the Special Technologies Laboratory, Remote Sensing Laboratory, etc. Building 914 was part of this characterization. The results of the 2002 study illustrated that the metal housekeeping limits were within acceptable limits and from a Be standpoint, the building was determined to be fit for occupancy. On March 2, 2011, based on a request from Building 914 users, National Security Technologies, LLC (NSTec) Industrial Hygiene (IH) collected bulk samples from the southwest corner of Building 914 at heights above 6 feet where black dust had been noticed on this particular wall. IH conducted surface swipe sampling of the area and analyzed the samples for toxic metals, namely, beryllium (Be), cadmium (Cd), chromium (Cr), lead (Pb), and manganese (Mn). The sample results indicated values two to four times above the housekeeping threshold for Be, Cd, Cr, Pb, and Mn. Subsequently, the facility was closed and posted; the necessary personnel were notified; and controls were instituted for ingress and egress of the building. On March 17, 2011, IH performed an extensive sampling event involving the entire warehouse in accordance with NSTec Organization Procedure OP-P250.004, Sampling Procedures. Analysis of the results from this exercise illustrated that toxic metal contamination was ubiquitous throughout the warehouse section of this building but did not extend into the office, restroom, and break room areas. On March 22, 2011, a planning meeting was held with Environment, Safety, Health & Quality management; Operations & Infrastructure (O&I) mangement; Facility Management; Occupational Medicine; O&I Operations; and IH. After a brief discussion concerning the salient facts of the surface sample results, it was agreed that the facility and its contents required cleaning. The facility would then be re-sampled to verify cleanliness and suitability for re-occupancy. On April 18, 2011, warehouse cleanup activites began. On July 5, 2011, upon receipt of the results from the last cleaned section, the cleanup operations were concluded. The building was statistically determined to be clean; thus, it could be reoccupied and the warehouse operations could resume immediately.« less
Spencer, Maureen; Vignari, Michelle; Bryce, Elizabeth; Johnson, Helen Boehm; Fauerbach, Loretta; Graham, Denise
2017-03-01
Environmental disinfection has become the new frontier in the ongoing battle to reduce the risk of health care-associated infections. Evidence demonstrating the persistent contamination of environmental surfaces despite traditional cleaning and disinfection methods has led to the widespread acceptance that there is both a need for reassessing traditional cleaning protocols and for using secondary disinfection technologies. Ultraviolet-C (UV-C) disinfection is one type of no-touch technology shown to be a successful adjunct to manual cleaning in reducing environmental bioburden. The dilemma for the infection preventionist, however, is how to choose the system best suited for their facility among the many UV-C surface disinfection delivery systems available and how to build a case for acquisition to present to the hospital administration/C-suite. This article proposes an approach to these dilemmas based in part on the experience of 2 health care networks. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.
None
2018-01-16
Highlights the research NETL is doing in the following fields: Clean Coal, Gasification, Carbon Sequestration, and Hydrogen. This video was featured in the lobby of the Forrestal building in Washington, D.C.
EPA Efforts in the Middle East
US EPA’s environmental cooperation in the Middle East focuses on capacity building in environmental governance, water pollution and water security, clean fuels and vehicles, public participation, and pollution prevention.
21 CFR 211.52 - Washing and toilet facilities.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Buildings and Facilities... cold water, soap or detergent, air driers or single-service towels, and clean toilet facilities easily...
21 CFR 211.52 - Washing and toilet facilities.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Buildings and Facilities... cold water, soap or detergent, air driers or single-service towels, and clean toilet facilities easily...
21 CFR 211.52 - Washing and toilet facilities.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Buildings and Facilities... cold water, soap or detergent, air driers or single-service towels, and clean toilet facilities easily...
21 CFR 211.52 - Washing and toilet facilities.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Buildings and Facilities... cold water, soap or detergent, air driers or single-service towels, and clean toilet facilities easily...
21 CFR 211.52 - Washing and toilet facilities.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) DRUGS: GENERAL CURRENT GOOD MANUFACTURING PRACTICE FOR FINISHED PHARMACEUTICALS Buildings and Facilities... cold water, soap or detergent, air driers or single-service towels, and clean toilet facilities easily...
ERIC Educational Resources Information Center
Coleman, Patrick J.; Lahey, Elizabeth; Orlando, Kristine
The Robert Taylor Boys and Girls Club of Chicago is located in this country's largest public housing development, serving over 1,500 predominantly African American members. It offers a brightly-colored building in a dilapidated, deprived area. It provides a clean, warm, safe haven for children to play, build strong bodies, get help with homework,…
The National Exposure Research Laboratory (NERL) Human Exposure and Atmospheric Sciences Division (HEASD) conducts research in support of EPA mission to protect human health and the environment. HEASD research program supports Goal 1 (Clean Air) and Goal 4 (Healthy People) of EP...
5. INTERIOR VIEW OF LAUNDRY ROOM ON GALLERY LEVEL, NEAR ...
5. INTERIOR VIEW OF LAUNDRY ROOM ON GALLERY LEVEL, NEAR SOUTHWEST CORNER OF BUILDING 149; WORKERS' UNIFORMS AND BEEF SHROUDS WERE LAUNDERED HERE; CLEAN BEEF SHROUDS WERE RETURNED TO DISASSEMBLY LINE ON LEVEL 4 THROUGH FUNNEL-SHAPED CHUTE AT LOWER LEFT - Rath Packing Company, Beef Killing Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
NASA Astrophysics Data System (ADS)
Mancini, S.; Caliendo, E.; Guida, M.; Bisceglia, B.
2017-10-01
The main purpose of the work described in this paper has been to establish the protocol for a new non-disruptive technique of intervention, based on microwave treatment, for cleaning operations on monumental historical buildings, to eliminate biodeteriogens infesting stones. Non-destructive methods in the cleaning operations, should not only preserve the physical integrity, the chemical-mineralogical and structural identity of materials, but, when the exhalation of pollutant agents (like for example Radon gas) from building materials is considered, also, make the indoor air quality (IAQ) levels healthy. Therefore, one of the main steps of the protocol proposed in this paper is concerned with the assessment of the Radon exhalation rate in order to verify that microwave treatments do not increase the Radon naturally exhalated by building materials. In this paper, the preliminary results of the Radon measurements performed on two different type of tuff samples (grey tuff and yellow tuff), typical of the Italian traditional construction heritage, with the E-PERM passive technique at the Environmental Radioactivity Laboratory (Amb.Ra.), University of Salerno, Italy, ISO 9001:2008 certified, are summarized.
31 CFR 11.6 - Terms of permit.
Code of Federal Regulations, 2013 CFR
2013-07-01
... normal cleaning, maintenance, and repair of the building structure in and adjacent to the vending... Treasury bureau; and that all plumbing, electrical, and mechanical costs related to the renovation of...
Solar energy to meet the nation's energy needs
NASA Technical Reports Server (NTRS)
Rom, F. E.; Thomas, R. L.
1973-01-01
Solar energy, being a non-depleting clean source of energy, is shown to be capable of providing energy in all the forms in which it is used today. It can be used to generate electricity, for heating and cooling buildings, and for producing clean renewable gaseous, liquid and solid fuel. There is little question of the technical feasibility for utilizing solar energy. The chief problem is rapidly providing innovative solutions that are economically competititive with other systems.
Orion EM-1 Crew Module Move from Clean Room to Work Station
2017-05-11
The Orion crew module pressure vessel for NASA’s Exploration Mission 1 (EM-1) is moved from a clean room to a work station inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida. Orion will undergo additional processing to prepare it for launch in 2019. The spacecraft is being prepared for its first integrated flight atop the Space Launch System rocket on Exploration Mission-1.
Orion EM-1 Crew Module Move from Clean Room to Work Station
2017-05-11
The Orion crew module pressure vessel for NASA’s Exploration Mission 1 (EM-1) is being moved from a clean room to a work station inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida. Orion will undergo additional processing to prepare it for launch in 2019. The spacecraft is being prepared for its first integrated flight atop the Space Launch System rocket on Exploration Mission-1.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gist, Ryan
This technical report summarizes the work completed by BioLite in fulfilment of the US DOE EERE award. The work plan focused on three key objectives: developing an optimized combustion system that demonstrates high combustion efficiency and low PM 2.5 and CO emissions, integrate the system into popular stove phenotypes – side-fed rocket stove architecture like the BioLite HomeStove, and the Patsari chimney stove in Mexico such that they maintain their important phenotypical characteristics, independently evaluate quantitative fuel and emissions performance of the integrated ‘Turbo-Patsari’ in Mexican households. The project activities were organized into six major tasks: A. Develop, fabricate, andmore » test proof-of-concept prototypes B. Develop field prototypes, assess user feedback and field performance C. Define revised stove design for pre-production model, Identify manufacturing requirements and estimated cost to build, Conduct reliability, emissions, and performance testing of pre-production Turbo-Patsari D. Build pre-production Turbo-Patsari stove combustion cores E. Conduct pre-production field trials F. Summarize field trial results and evaluate Turbo-Patsari for potential volume production. A two-pronged approach was adopted for the above tasks. The first involved building a modular test platform that allowed parametric variation of multiple stove design parameters that directly affect its performance – heat output, thermal efficiency, and emissions. The second part of the approach comprised of building a surrogate Patsari based on GIRA’s specifications that could then be modified or retrofitted for optimum performance based on the learnings from the modular test platform. The following sections of the report will describe the findings of tests on these platform, the subsequent development, design, and installation of the Turbo-Patsari, and finally the in-home field trial.« less
... from non-smokers (like “no smoking” sections in restaurants)‚ cleaning the air‚ and airing out buildings does ... care staff do not smoke. Eat at smokefree restaurants. Avoid indoor public places that allow smoking. Teach ...
NASA Technical Reports Server (NTRS)
2002-01-01
The Supersonic Gas/Liquid Cleaning System (SS-GLCS) has applications ranging from cleaning circuit boards to scouring building exteriors. The system does not abrade the surface of the hardware being cleaned, and it requires much lower levels of pressure while using very little water. An alternative to CFC-based solvents, the system mixes air and water from separate pressurized tanks, ejecting the gas- liquid mixture at supersonic speeds from a series of nozzles at the end of a hand-held wand. The water droplets have the kinetic energy to forcibly remove the contaminant material. The system leaves very little fluid that must be handled as contaminated waste. It can be applied in the aerospace, automotive, and medical industries, as well as to circuit boards, electronics, machinery, metals, plastics, and optics. With a nozzle that can be oriented in any direction, the system is adjustable to allow all sides of a part to be cleaned without reorientation. It requires minimal training and is easily moved on built-in casters
Risk in cleaning: chemical and physical exposure.
Wolkoff, P; Schneider, T; Kildesø, J; Degerth, R; Jaroszewski, M; Schunk, H
1998-04-23
Cleaning is a large enterprise involving a large fraction of the workforce worldwide. A broad spectrum of cleaning agents has been developed to facilitate dust and dirt removal, for disinfection and surface maintenance. The cleaning agents are used in large quantities throughout the world. Although a complex pattern of exposure to cleaning agents and resulting health problems, such as allergies and asthma, are reported among cleaners, only a few surveys of this type of product have been performed. This paper gives a broad introduction to cleaning agents and the impact of cleaning on cleaners, occupants of indoor environments, and the quality of cleaning. Cleaning agents are usually grouped into different product categories according to their technical functions and the purpose of their use (e.g. disinfectants and surface care products). The paper also indicates the adverse health and comfort effects associated with the use of these agents in connection with the cleaning process. The paper identifies disinfectants as the most hazardous group of cleaning agents. Cleaning agents contain evaporative and non-evaporative substances. The major toxicologically significant constituents of the former are volatile organic compounds (VOCs), defined as substances with boiling points in the range of 0 degree C to about 400 degrees C. Although laboratory emission testing has shown many VOCs with quite different time-concentration profiles, few field studies have been carried out measuring the exposure of cleaners. However, both field studies and emission testing indicate that the use of cleaning agents results in a temporal increase in the overall VOC level. This increase may occur during the cleaning process and thus it can enhance the probability of increased short-term exposure of the cleaners. However, the increased levels can also be present after the cleaning and result in an overall increased VOC level that can possibly affect the indoor air quality (IAQ) perceived by occupants. The variety and duration of the emissions depend inter alia on the use of fragrances and high boiling VOCs. Some building materials appear to increase their VOC emission through wet cleaning and thus may affect the IAQ. Particles and dirt contain a great variety of both volatile and non-volatile substances, including allergens. While the volatile fraction can consist of more than 200 different VOCs including formaldehyde, the non-volatile fraction can contain considerable amounts (> 0.5%) of fatty acid salts and tensides (e.g. linear alkyl benzene sulphonates). The level of these substances can be high immediately after the cleaning process, but few studies have been conducted concerning this problem. The substances partly originate from the use of cleaning agents. Both types are suspected to be airway irritants. Cleaning activities generate dust, mostly by resuspension, but other occupant activities may also resuspend dust over longer periods of time. Personal sampling of VOCs and airborne dust gives higher results than stationary sampling. International bodies have proposed air sampling strategies. A variety of field sampling techniques for VOC and surface particle sampling is listed.
... U.S. Environmental Protection Agency (EPA) guide titled Mold Remediation in Schools and Commercial Buildings . Also available is ... Resources NIOSH Interim Recommendations for the Cleaning and Remediation of Flood-Contaminated HVAC Systems: A Guide for ...
20 CFR 701.301 - Definitions and use of terms.
Code of Federal Regulations, 2011 CFR
2011-04-01
... involved in the controlled cultivation and harvest of aquatic plants and animals, including the cleaning... controlled growing and harvesting of other aquatic species; or (F) Individuals engaged in the building...
Efficacy of Cleaning and Disinfection Procedures in a Zebrafish (Danio rerio) Facility
Garcia, Rachel L; Sanders, George E
2011-01-01
Appropriate cleaning and disinfection procedures in zebrafish (Danio rerio) laboratories are crucial in preventing the spread of aquatic animal pathogens and minimizing the build-up of waste products and biologic matter. The procedures selected should accomplish these goals and incorporate the individual needs of various laboratories. In this study of a single zebrafish facility, we assessed the efficacy of 2 different cleaning and disinfection procedures for nets, tanks, and lids. ATP levels were used as a surrogate biomarker for microbial burden. We measured the number of relative light units (RLU), as an expression of the amount of ATP present, on items before and after disinfection and calculated the percentage reduction. We compared daily replacement of a commercial net disinfection product in J lab with weekly replacement in H lab and found a 96.6% reduction in RLU in H lab and a 91.2% reduction in J lab. These results indicate that either replacement schedule is effective. Evaluation of tanks and lids soaked in a bleach disinfection bath for 30 or 60 min revealed a 99.7% reduction in RLU at 30 min compared with 97.1% at 60 min. Therefore a 30-min soak in a bleach bath achieved a similar level of disinfection as did a 60-min soak. The current results demonstrate that these cleaning and disinfection methods are efficacious. PMID:22330783
Efficacy of cleaning and disinfection procedures in a zebrafish (Danio rerio) facility.
Garcia, Rachel L; Sanders, George E
2011-11-01
Appropriate cleaning and disinfection procedures in zebrafish (Danio rerio) laboratories are crucial in preventing the spread of aquatic animal pathogens and minimizing the build-up of waste products and biologic matter. The procedures selected should accomplish these goals and incorporate the individual needs of various laboratories. In this study of a single zebrafish facility, we assessed the efficacy of 2 different cleaning and disinfection procedures for nets, tanks, and lids. ATP levels were used as a surrogate biomarker for microbial burden. We measured the number of relative light units (RLU), as an expression of the amount of ATP present, on items before and after disinfection and calculated the percentage reduction. We compared daily replacement of a commercial net disinfection product in J lab with weekly replacement in H lab and found a 96.6% reduction in RLU in H lab and a 91.2% reduction in J lab. These results indicate that either replacement schedule is effective. Evaluation of tanks and lids soaked in a bleach disinfection bath for 30 or 60 min revealed a 99.7% reduction in RLU at 30 min compared with 97.1% at 60 min. Therefore a 30-min soak in a bleach bath achieved a similar level of disinfection as did a 60-min soak. The current results demonstrate that these cleaning and disinfection methods are efficacious.
[Evaluation of Medical Instruments Cleaning Effect of Fluorescence Detection Technique].
Sheng, Nan; Shen, Yue; Li, Zhen; Li, Huijuan; Zhou, Chaoqun
2016-01-01
To compare the cleaning effect of automatic cleaning machine and manual cleaning on coupling type surgical instruments. A total of 32 cleaned medical instruments were randomly sampled from medical institutions in Putuo District medical institutions disinfection supply center. Hygiena System SUREII ATP was used to monitor the ATP value, and the cleaning effect was evaluated. The surface ATP values of the medical instrument of manual cleaning were higher than that of the automatic cleaning machine. Coupling type surgical instruments has better cleaning effect of automatic cleaning machine before disinfection, the application is recommended.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tremaine, Diana; Douglas, Steven G.
2012-07-01
The Y-12 National Security Complex in Oak Ridge, TN has faced an ongoing challenge from mercury entrapped in soils beneath and adjacent to buildings, storm sewers, and process pipelines. Previous actions to reduce the quantity and/or mobilization of mercury-contaminated media have included plugging of building floor drains, cleaning of sediment and sludge from sumps, manholes, drain lines, and storm sewers, lining/relining of storm sewers and replacement of a portion of the storm sewer trunk line, re-routing and removal of process piping, and installation of the Central Mercury Treatment System to capture and treat contaminated sump water. Despite the success ofmore » these actions, mercury flux in the storm sewer out-falls that discharge to Upper East Fork Poplar Creek (UEFPC) continues to pose a threat to long-term water quality. A video camera survey of the storm sewer network revealed several sections of storm sewer that had large cracks, separations, swells, and accumulations of sediment/sludge and debris. The selected remedy was to clean and line the sections of storm sewer pipe that were determined to be primary contributors to the mercury flux in the storm sewer out-falls. The project, referred to as the West End Mercury Area (WEMA) Storm Sewer Remediation Project, included cleaning sediment and debris from over 2,460 meters of storm sewer pipe followed by the installation of nearly 366 meters of cure-in-place pipe (CIPP) liner. One of the greatest challenges to the success of this project was the high cost of disposal associated with the mercury-contaminated sludge and wastewater generated from the storm sewer cleaning process. A contractor designed and operated an on-site wastewater pre-treatment system that successfully reduced mercury levels in 191 cubic meters of sludge to levels that allowed it to be disposed at Nevada Nuclear Security Site (NNSS) disposal cell as a non-hazardous, low-level waste. The system was also effective at pre-treating over 1,514,000 liters of wastewater to levels that met the waste acceptance criteria for the on-site West End [wastewater] Treatment Facility (WETF). This paper describes the storm sewer cleaning and lining process and the methods used to process the mercury-contaminated sludge and wastewater, as well as several 'lessons learned' that would be relevant to any future projects involving storm sewer cleaning and debris remediation. (authors)« less
NANOSTRUCTURED METAL OXIDE CATALYSTS VIA BUILDING BLOCK SYNTHESES
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig E. Barnes
2013-03-05
A broadly applicable methodology has been developed to prepare new single site catalysts on silica supports. This methodology requires of three critical components: a rigid building block that will be the main structural and compositional component of the support matrix; a family of linking reagents that will be used to insert active metals into the matrix as well as cross link building blocks into a three dimensional matrix; and a clean coupling reaction that will connect building blocks and linking agents together in a controlled fashion. The final piece of conceptual strategy at the center of this methodology involves dosingmore » the building block with known amounts of linking agents so that the targeted connectivity of a linking center to surrounding building blocks is obtained. Achieving targeted connectivities around catalytically active metals in these building block matrices is a critical element of the strategy by which single site catalysts are obtained. This methodology has been demonstrated with a model system involving only silicon and then with two metal-containing systems (titanium and vanadium). The effect that connectivity has on the reactivity of atomically dispersed titanium sites in silica building block matrices has been investigated in the selective oxidation of phenols to benezoquinones. 2-connected titanium sites are found to be five times as active (i.e. initial turnover frequencies) than 4-connected titanium sites (i.e. framework titanium sites).« less
Parkinson, Don-Roger; Churchill, Tonia J; Rolls, Wyn
2008-11-01
Methyl benzoate - as a biomarker for mold growth - was used as a specific target compound to indicate outgassed MVOC products from mold. Both real and surrogate samples were analyzed from a variety of matrices including: carpet, ceiling tiles, dried paint surfaces, wallboard and wallboard paper. Sampling parameters, including: desorption, extraction time, incubation temperature, pH, salt effects and spinning rate, were optimized. Results suggest that extraction and detection of methyl benzoate amongst other MVOCs can be accomplished cleanly by SPME-GC/MS methods. With detection limits (LOD = 1.5 ppb) and linearity (0.999) over a range of 100 ppm to 2 ppb, this work demonstrates that such a green technique can be contemplated for use in quick assessment or as part of an ongoing assessment strategy to detect mold growth in common indoor buildings and materials for both qualitative and quantitative determinations. Of importance, no matrix effects are observed under optimized extraction conditions.
Assessing airborne aflatoxin B1 during on-farm grain handling activities.
Selim, M I; Juchems, A M; Popendorf, W
1998-04-01
The presence of aflatoxin in corn and corn dust during relatively normal years and the increased risk of Aspergillus flavus infestation during drought conditions suggest that airborne agricultural exposures should be of considerable concern. Liquid extraction, thin layer chromatography, and high pressure liquid chromatography were used for the analysis of aflatoxin B1 in grain dust and bulk corn samples. A total of 24 samples of airborne dust were collected from 8 farms during harvest, 22 samples from 9 farms during animal feeding, and 14 sets of Andersen samples from 11 farms during bin cleaning. A total of 14 samples of settled dust and 18 samples of bulk corn were also collected and analyzed. The airborne concentration of aflatoxin B1 found in dust collected during harvest and grain unloading ranged from 0.04 to 92 ng/m3. Higher levels of aflatoxin B1 were found in the airborne dust samples collected from enclosed animal feeding buildings (5-421 ng/m3) and during bin cleaning (124-4849 ng/m3). Aflatoxin B1 up to 5100 ng/g were detected in settled dust collected from an enclosed animal feeding building; however, no apparent correlation was found between the airborne concentration of aflatoxin B1 and its concentration in settled dust or bulk corn. The data demonstrate that farmers and farm workers may be exposed to potentially hazardous concentrations of aflatoxin B1, particularly during bin cleaning and animal feeding in enclosed buildings.
Blades of Glory: An Energy.gov Mini-Doc – The 2016 Collegiate Wind Competition
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zayas, Jose; Newcomb, Charles
2016-06-06
In this short documentary, we follow three collegiate teams who are participating in this year’s U.S. Department of Energy Collegiate Wind Competition in New Orleans. Learn about their experiences and why the competition is important for America’s clean energy future. The competition provides undergraduates with real-world skills they need to enter tomorrow’s clean energy workforce by challenging them to develop and deliver a business plan, establish a deployment strategy, and build and test a wind turbine.
Orion EM-1 Crew Module Move from Clean Room to Work Station
2017-05-11
Workers have moved the Orion crew module pressure vessel for NASA’s Exploration Mission 1 (EM-1) out of a clean room inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida. The crew module will be moved to a work station where it will undergo additional processing to prepare it for launch in 2019. The spacecraft is being prepared for its first integrated flight atop the Space Launch System rocket on Exploration Mission-1.
Meneses, Yulie E; Flores, Rolando A
2016-05-01
Water scarcity is threatening food security and business growth in the United States. In the dairy sector, most of the water is used in cleaning applications; therefore, any attempt to support water conservation in these processes will have a considerable effect on the water footprint of dairy products. This study demonstrates the viability for recovering good quality water from whey, a highly pollutant cheese-making by-product, to be reused in cleaning-in-place systems. The results obtained in this study indicate that by using a combined ultrafiltration and reverse osmosis system, 47% of water can be recovered. This system generates protein and lactose concentrates, by-products that once spray-dried fulfill commercial standards for protein and lactose powders. The physicochemical and microbiological quality of the recovered permeate was also analyzed, suggesting suitable properties to be reused in the cleaning-in-place system without affecting the quality and safety of the product manufactured on the cleaned equipment. A cost analysis was conducted for 3 cheese manufacturing levels, considering an annual production of 1, 20, and 225 million liters of whey. Results indicate the feasibility of this intervention in the dairy industry, generating revenues of $0.18, $3.05, and $33.4 million per year, respectively. The findings provide scientific evidence to promote the safety of reuse of reconditioned water in food processing plants, contributing to building a culture of water conservation and sustainable production throughout the food supply chain. Copyright © 2016 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Identifying Sources of Volatile Organic Compounds and Aldehydes in a High Performance Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ortiz, Anna C.; Russell, Marion; Lee, Wen-Yee
The developers of the Paharpur Business Center (PBC) and Software Technology Incubator Park in New Delhi, India offer an environmentally sustainable building with a strong emphasis on energy conservation, waste minimization and superior indoor air quality (IAQ). To achieve the IAQ goal, the building utilizes a series of air cleaning technologies for treating the air entering the building. These technologies include an initial water wash followed by ultraviolet light treatment and biolfiltration using a greenhouse located on the roof and numerous plants distributed throughout the building. Even with the extensive treatment of makeup air and room air in the PBC,more » a recent study found that the concentrations of common volatile organic compounds and aldehydes appear to rise incrementally as the air passes through the building from the supply to the exhaust. This finding highlights the need to consider the minimization of chemical sources in buildings in combination with the use of advanced air cleaning technologies when seeking to achieve superior IAQ. The goal of this project was to identify potential source materials for indoor chemicals in the PBC. Samples of building materials, including wood paneling (polished and unpolished), drywall, and plastic from a hydroponic drum that was part of the air cleaning system, were collected from the building for testing. All materials were collected from the PBC building and shipped to the Lawrence Berkeley National Laboratory (LBNL) for testing. The materials were pre-conditioned for two different time periods before measuring material and chemical specific emission factors for a range of VOCs and Aldehydes. Of the six materials tested, we found that the highest emitter of formaldehyde was new plywood paneling. Although polish and paint contribute to some VOC emissions, the main influence of the polish was in altering the capacity of the surface to accumulate formaldehyde. Neither the new nor aged polish contributed significantly to formaldehyde emissions. The VOC emission stream (excluding formaldehyde) was composed of up to 18 different chemicals and the total VOC emissions ranged in magnitude from 7 mu g/m2/h (old wood with old polish) to>500 mu g/m2/h (painted drywall). The formaldehyde emissions from drywall and old wood with either new or old polish were ~;;15 mu g/m2/h while the new wood material emitted>100 mu g/m2/h. However, when the projected surface area of each material in the building was considered, the new wood, old wood and painted drywall material all contributed substantially to the indoor formaldehyde loading while the coatings contributed primarily to the VOCs.« less
Energy savings in Polish buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Markel, L.C.; Gula, A.; Reeves, G.
1995-12-31
A demonstration of low-cost insulation and weatherization techniques was a part of phase 1 of the Krakow Clean Fossil Fuels and Energy Efficient Project. The objectives were to identify a cost-effective set of measures to reduce energy used for space heating, determine how much energy could be saved, and foster widespread implementation of those measures. The demonstration project focused on 4 11-story buildings in a Krakow housing cooperative. Energy savings of over 20% were obtained. Most important, the procedures and materials implemented in the demonstration project have been adapted to Polish conditions and applied to other housing cooperatives, schools, andmore » hospitals. Additional projects are being planned, in Krakow and other cities, under the direction of FEWE-Krakow, the Polish Energie Cities Network, and Biuro Rozwoju Krakowa.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Torrens, I.M.; Stenzel, W.C.
Independent power producers will build a substantial fraction of expected new coal-fired power generation in developing countries over the coming decades. To reduce perceived risk and obtain financing for their projects, they are currently building and plan to continue to build subcritical coal-fired plants with generating efficiency below 40%. Up-to-date engineering assessment leads to the conclusion that supercritical generating technology, capable of efficiencies of up to 45%, can produce electricity at a lower total cost than conventional plants. If such plants were built in Asia over the coming decades, the savings in carbon dioxide emissions over their lifetime would bemore » measured in billions of tons. IPPs perceive supercritical technology as riskier and higher cost than conventional technology. The truth needs to be confirmed by discussions with additional experienced power engineering companies. Better communication among the interested parties could help to overcome the IPP perception issue. Governments working together with industry might be able to identify creative financing arrangements which can encourage the use of more efficient pulverized clean coal technologies, while awaiting the commercialization of advanced clean coal technologies like gasification combined cycle and pressurized fluidized bed combustion.« less
Impacts: NIST Building and Fire Research Laboratory (technical and societal)
NASA Astrophysics Data System (ADS)
Raufaste, N. J.
1993-08-01
The Building and Fire Research Laboratory (BFRL) of the National Institute of Standards and Technology (NIST) is dedicated to the life cycle quality of constructed facilities. The report describes major effects of BFRL's program on building and fire research. Contents of the document include: structural reliability; nondestructive testing of concrete; structural failure investigations; seismic design and construction standards; rehabilitation codes and standards; alternative refrigerants research; HVAC simulation models; thermal insulation; residential equipment energy efficiency; residential plumbing standards; computer image evaluation of building materials; corrosion-protection for reinforcing steel; prediction of the service lives of building materials; quality of construction materials laboratory testing; roofing standards; simulating fires with computers; fire safety evaluation system; fire investigations; soot formation and evolution; cone calorimeter development; smoke detector standards; standard for the flammability of children's sleepwear; smoldering insulation fires; wood heating safety research; in-place testing of concrete; communication protocols for building automation and control systems; computer simulation of the properties of concrete and other porous materials; cigarette-induced furniture fires; carbon monoxide formation in enclosure fires; halon alternative fire extinguishing agents; turbulent mixing research; materials fire research; furniture flammability testing; standard for the cigarette ignition resistance of mattresses; support of navy firefighter trainer program; and using fire to clean up oil spills.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kopotic, James D.; Ferri, Mark S.; Buttram, Claude
The East Tennessee Technology Park (ETTP) is the site of five former gaseous diffusion plant (GDP) process buildings that were used to enrich uranium from 1945 to 1985. The process equipment in the original two buildings (K-25 and K-27) was used for the production of highly enriched uranium (HEU), while that in the three later buildings (K-29, K-31 and K-33) produced low enriched uranium (LEU). Equipment was contaminated primarily with uranium and to a lesser extent technetium (Tc). Decommissioning of the GDP process buildings has presented several unique challenges and produced many lessons-learned. Among these is the importance of good,more » up-front characterization in developing the best demolition approach. Also, chemical cleaning of process gas equipment and piping (PGE) prior to shutdown should be considered to minimize the amount of hold-up material that must be removed by demolition crews. Another lesson learned is to maintain shutdown buildings in a dry state to minimize structural degradation which can significantly complicate characterization, deactivation and demolition efforts. Perhaps the most important lesson learned is that decommissioning GDP process buildings is first and foremost a waste logistics challenge. Innovative solutions are required to effectively manage the sheer volume of waste generated from decontamination and demolition (D and D) of these enormous facilities. Finally, close coordination with Security is mandatory to effectively manage Special Nuclear Material (SNM) and classified equipment issues. (authors)« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Telesca, D.R.
A control technology survey was conducted at the coal gasification facility of the Caterpillar Tractor Company (SIC-5161), in York, Pennsylvania on August 18, 1980 and May 7, 1981, in conjunction with an industrial hygiene characterization study. Potential hazards included coal dust, noise, fire, carbon-monoxide (630080) (CO), polynuclear aromatics, hydrogen sulfide (7783064), phenols, and flammable and explosive gases. Preemployment physicals were given to employees including complete medical histories, physical examinations, and skin examination. Examinations were given annually for the first 5 years and semiannually thereafter. The most hazardous activities were poking, cleaning, inspection of process equipment, and equipment maintenance. Coal dustmore » emissions were effectively reduced by enclosure and venting. Venturi steam injectors in the gasifier pokeholes prevented gas emissions during poking. Ash dust was controlled by removal and handling while it was wet. An audible and visual alarm was used for CO monitoring. The ventilation system in the building effectively prevented accumulation of gases. The author recommends separate lockers for contaminated and clean clothing; a clean area for eating; escape pack respirators located in the rectifier room, control room, and coal bunker; and supplied air respirators in dangerous areas. Disposal of off gas from the feeding system should be addressed.« less
Multimodal transport and TransLoad facilities in Arkansas.
DOT National Transportation Integrated Search
2015-01-01
National Priorities consist of building a clean and ecient 21st century : transportation sector, and Multimodal Transportation is one of ve : Transportation System Eciency strategies at the US Department of Energy. Six : locomotives co...
76 FR 17671 - Notice of Proposed Consent Decree Under the Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-30
... Acquisition Corporation's bulk gasoline terminal in Saipan, Northern Marianas Islands. The violations include... Building, P.O. Box 500377, Saipan, MP 96950. During the public comment period, the proposed agreements may...
Energy Conservation--Hero or Villian?
ERIC Educational Resources Information Center
Keith, William J. B.
1985-01-01
Energy conservation efforts have often hermetically sealed buildings without concern for air quality. The Waterloo County Board of Education, Ontario, has installed indicators to test air quality and has installed a "clean room" for children with allergies. (MLF)
Impact of Clean Energy R&D on the U.S. Power Sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Donohoo-Vallett, Paul; Mai, Trieu; Mowers, Matthew
The U.S. government, along with other governments, private corporations and organizations, invests significantly in research, development, demonstration and deployment (RDD&D) activities in clean energy technologies, in part to achieve the goal of a clean, secure, and reliable energy system. While specific outcomes and breakthroughs resulting from RDD&D investment are unpredictable, it can be instructive to explore the potential impacts of clean energy RDD&D activities in the power sector and to place those impacts in the context of current and anticipated market trends. This analysis builds on and leverages analysis by the U.S. Department of Energy (DOE) titled “Energy CO 2more » Emissions Impacts of Clean Energy Technology Innovation and Policy” (DOE 2017). Similar to DOE (2017), we explore how additional improvements in cost and performance of clean energy technologies could impact the future U.S. energy system; however, unlike the economy-wide modeling used in DOE (2017) our analysis is focused solely on the electricity sector and applies a different and more highly spatially-resolved electric sector model. More specifically, we apply a scenario analysis approach to explore how assumed further advancements in clean electricity technologies would impact power sector generation mix, electricity system costs, and power sector carbon dioxide (CO 2) emissions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ward, C.R.
2003-04-08
On December 2, 2002, Remote and Specialty Equipment Systems (RSES) of the Savannah River Technology Center (SRTC) was requested to build a remotely operated crawler to assist in cleaning the Defense Waste Processing Facility (DWPF) melt cell floor of glass, tools, and other debris. The crawler was to assist a grapple and vacuum system in cleaning the cell. The crawler was designed to push glass and debris into piles so that the grapple could pick up the material and place it in waste bins. The crawler was also designed to maneuver the end of the vacuum hose, if needed. Inmore » addition, the crawler was designed to clean the area beneath the cell worktable that was inaccessible to the grapple and vacuum system. Originally, the system was to be ready for deployment by December 17. The date was moved up to December 12 to better utilize the available time for clean up. The crawler was designed and built in 10 days and completed cleaning the melt cell in 8 days. Due to initial problems with the grapple and vacuum system, the crawler completed essentially all of the cleanup tasks by itself. The crawler also cleaned an area on the west side of the cell that was not initially slated for cleaning.« less
Cleaning Up the Joint: Command, Control, and Agency in American War Fighting
2012-01-01
markers of the rise of professionalism . Constabulary duties on the frontier provided no compelling intellectual locus on which to build a theory of war...Docks; Construction , Equipment and Repairs; Provisions and Clothing; Ordnance and Hydrography; and Medicine and Surgery.80 Its professionalism , however...advisors seem to have convinced themselves otherwise, forcible regime change is by definition a nation- building project of the highest order.67 When
Layer by Layer Growth of 2D Quantum Superlattices (NBIT III)
2017-02-28
building quantum superlatticies using 2D materials as the building blocks. Specifically, we develop methods that allow i) large-scale growth of aligned...superlattice and heterostructures, iii) lateral and clean patterning of 2D materials for atomically-thin circuitry and iv) novel physical properties...high precision and flexibility beyond conventional methods. Moreover, it provides the solutions for current major barrier for 2D materials (e.g
NASA Astrophysics Data System (ADS)
Gaggero, Laura; Ferretti, Maurizio; Torrielli, Giulia; Caratto, Valentina
2016-04-01
Porous materials (e.g. plasters, mortars, concrete, and the like) used in the building industry or in artworks fail to develop, after their genesis, salts such as nitrates, carbonates (e.g. potassium carbonate, magnesium carbonate, calcium carbonate), chlorides (e.g. sodium chloride) and/or others, which are a concurrent cause of material deterioration phenomena. In the case of ancient or cultural heritage buildings, severe damage to structures and works of art, such as fresco paintings are possible. In general, in situ alteration pattern in mortars and frescoes by crystallization of soluble salts from solutions is caused by capillar rise or circulation in damp walls. Older buildings can be more subject to capillary rise of ion-rich waters, which, as water evaporates, create salt crystals inside the walls. If this pattern reveals overwhelming upon other environmental decay factors, the extraction of salts is the first restoration to recover the artpiece after the preliminary assessment and mitigation of the causes of soaking. A new method and apparatus, patented by University of Genoa [1] improves the quality and durability of decontamination by soluble salts, compared with conventional application of sepiolite or cellulose wraps. The conventional application of cellulose or sepiolite requires casting a more or less thick layer of wrap on the mortar, soaking with distilled water, and waiting until dry. The soluble salts result trapped within the wrap. A set of artificial samples reproducing the stratigraphy of frescoes was contaminated with saline solution of known concentration. The higher quality of the extraction was demonstrated by trapping the salts within layers of Japanese paper juxtaposed to the mortar; the extraction with the dedicated apparatus was operated in a significantly shorter time than with wraps (some hours vs. several days). Two cycles of about 15 minutes are effective in the deep cleaning from contaminant salts. The decontamination was demonstrated by conducibility tests on the juxtaposed Japanese paper. In addition, after the conventional treatment, a considerable amount of soluble salts was further extracted demonstrating that traditional wraps operate just a shallow cleaning, and soluble salts are liable to emerge later as efflorescence affecting the conservation after restoration. The optimum cleaning was obtained by finishing the innovative extraction with sepiolite/cellulose wraps. As a whole, the novel method and apparatus enhance the time for restoration and the final quality before consolidation and protection. [1] "Apparatus and method for treating porous materials" - M. Ferretti, L. Gaggero, G. Torrielli, PCT/IB2015/055129 (2015)
Testing antimicrobial cleaner efficacy on gypsum wallboard contaminated with Stachybotrys chartarum.
Menetrez, Marc Y; Foarde, Karin K; Webber, Tricia D; Dean, Timothy R; Betancourt, Doris A
2007-11-01
Reducing occupant exposure to indoor mold is the goal of this research, through the efficacy testing of antimicrobial cleaners. Often mold contaminated building materials are not properly removed, but instead surface cleaners are applied in an attempt to alleviate the problem. The efficacy of antimicrobial cleaners to remove, eliminate or control mold growth on surfaces can easily be tested on non-porous surfaces. However, the testing of antimicrobial cleaner efficacy on porous surfaces, such as those found in the indoor environment such as gypsum board can be more complicated and prone to incorrect conclusions regarding residual organisms. The mold Stachybotrys chartarum has been found to be associated with idiopathic pulmonary hemorrhage in infants and has been studied for toxin production and its occurrence in water damaged buildings. Growth of S. chartarum on building materials such as gypsum wallboard has been frequently documented. Research to control S. chartarum growth using 13 separate antimicrobial cleaners on contaminated gypsum wallboard has been performed in laboratory testing. Popular brands of cleaning products were tested by following directions printed on the product packaging. A variety of gypsum wallboard surfaces were used to test these cleaning products at high relative humidity. The results indicate differences in antimicrobial efficacy for the six month period of testing. Results for the six types of GWB surfaces varied extensively. However, three cleaning products exhibited significantly better results than others. Lysol All-Purpose Cleaner-Orange Breeze (full strength) demonstrated results which ranked among the best in five of the six surfaces tested. Both Borax and Orange Glo Multipurpose Degreaser demonstrated results which ranked among the best in four of the six surfaces tested. The best antimicrobial cleaner to choose is often dependent on the type of surface to be cleaned of S. chartarum contamination. For Plain GWB, no paint, the best cleaners were Borax, Lysol All-Purpose Cleaner-Orange Breeze (full strength), Orange Glo Multipurpose Degreaser, and Fantastik Orange Action. These results are not meant to endorse the incomplete removal of mold contaminated building materials. However, it is recognized that complete removal may not always be possible and solutions to control mold regrowth may contribute to reduced occupant exposure. Current recommendations of removal and replacement of porous building materials should be followed. It is not the intension of this discussion to endorse any product. Reporting on the performance of these products under the stated conditions was and remains the only purpose.
Mineral of the month: chromium
Papp, John F.
2005-01-01
Chromium is one of the most indispensable industrial metals and it plays an essential but hidden role in daily life. Chromium is used in many consumer and building products, and it contributes to a clean, efficient and healthy environment.
Where Have All the Custodians Gone?
ERIC Educational Resources Information Center
Fickes, Michael
2001-01-01
Examines how to reduce college and university custodial turnover rates by forging connections between the job and the campus community. Key points to building these connections are outlined, including training requirements, benefit compensation package design, and cleaning strategies. (GR)
VIEW OF MILL FROM KEKAHA ROAD, WITH SUGAR BIN, CANE ...
VIEW OF MILL FROM KEKAHA ROAD, WITH SUGAR BIN, CANE CLEANING PLANT AND CRUSHING MILL TO THE FORE. VIEW FROM THE EAST - Kekaha Sugar Company, Sugar Mill Building, 8315 Kekaha Road, Kekaha, Kauai County, HI
A Healthy School Is just What the Doctor Ordered
ERIC Educational Resources Information Center
Modern Schools, 1973
1973-01-01
Discusses key factors to be considered by local educational authorities in creating a healthful -- and consequently constructive -- environment in the school building for students, teachers, and administrators. Focuses on ventilation, air cleaning, and humidification. (EA)
Environmental Standards for Storage of Books and Manuscripts
ERIC Educational Resources Information Center
Banks, Paul N.
1974-01-01
Deals with those factors included in building planning that can influence preservation, deterioration, or destruction of books--temperature, humidity, light, air cleanness, ventilation, exhibition, shelving and transportation, storage of microfilm, disaster control, and monitoring systems. (CH)
ERIC Educational Resources Information Center
International Federation of Library Associations, The Hague (Netherlands).
The 15 papers in this compilation focus on library nagement and technology, including information technology, statistics, buildings and equipment, and conservation: (1) "Information Control: OSI (Open Systems Interconnection) and Networking Strategies" (Neil McClean, United Kingdom); (2) "OSI in Australia: Potential, Planning,…
Elements that contribute to healthy building design.
Loftness, Vivian; Hakkinen, Bert; Adan, Olaf; Nevalainen, Aino
2007-06-01
The elements that contribute to a healthy building are multifactorial and can be discussed from different perspectives. WE PRESENT THREE VIEWPOINTS OF DESIGNING A HEALTHY BUILDING: the importance of sustainable development, the role of occupants for ensuring indoor air quality, and ongoing developments related to indoor finishes with low chemical emissions and good fungal resistance. Sustainable design rediscovers the social, environmental, and technical values of pedestrian and mixed-use communities, using existing infrastructures including "main streets" and small-town planning principles and recapturing indoor-outdoor relationships. This type of design introduces nonpolluting materials and assemblies with lower energy requirements and higher durability and recyclability. Building occupants play a major role in maintaining healthy indoor environments, especially in residences. Contributors to indoor air quality include cleaning habits and other behaviors; consumer products, furnishings, and appliances purchases, as well as where and how the occupants use them. Certification of consumer products and building materials as low-emitting products is a primary control measure for achieving good indoor air quality. Key products in this respect are office furniture, flooring, paints and coatings, adhesives and sealants, wall coverings, wood products, textiles, insulation, and cleaning products. Finishing materials play a major role in the quality of indoor air as related to moisture retention and mold growth. Sustainable design emphasizes the needs of infrastructure, lower energy consumption, durability, and recyclability. To ensure good indoor air quality, the product development for household use should aim to reduce material susceptibility to contaminants such as mold and should adopt consumer-oriented product labeling.
Southern California Regional Technology Acceleration Program
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ochoa, Rosibel; Rasochova, Lada
2014-09-30
UC San Diego and San Diego State University are partnering to address these deficiencies in the renewable energy space in the greater San Diego region, accelerating the movement of clean energy innovation from the university laboratory into the marketplace, building on the proven model of the William J. von Liebig Center’s (vLC’s) Proof of Concept (POC) program and virtualizing the effort to enable a more inclusive environment for energy innovation and expansion of the number of clean energy start-ups and/or technology licenses in greater California.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) is being moved to a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, Lockheed Martin technicians move the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) into a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, Lockheed Martin technicians move the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) toward a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Effect of outside air ventilation rate on VOC concentrations and emissions in a call center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodgson, A.T.; Faulkner, D.; Sullivan, D.P.
2002-01-01
A study of the relationship between outside air ventilation rate and concentrations of VOCs generated indoors was conducted in a call center. Ventilation rates were manipulated in the building's four air handling units (AHUs). Concentrations of VOCs in the AHU returns were measured on 7 days during a 13-week period. Indoor minus outdoor concentrations and emission factors were calculated. The emission factor data was subjected to principal component analysis to identify groups of co-varying compounds based on source type. One vector represented emissions of solvents from cleaning products. Another vector identified occupant sources. Direct relationships between ventilation rate and concentrationsmore » were not observed for most of the abundant VOCs. This result emphasizes the importance of source control measures for limiting VOC concentrations in buildings.« less
17. VIEW OF THE DIAMOND MINEYARD LOOKING NORTHEAST. THE DRIES ...
17. VIEW OF THE DIAMOND MINEYARD LOOKING NORTHEAST. THE DRIES ARE ON THE LEFT, WITH THE TAR HOUSE, TOILET, AND ROPE CLAMP CLEANING BUILDING TO THE RIGHT - Butte Mineyards, Diamond Mine, Butte, Silver Bow County, MT
... to not allow smoking indoors. Separating smokers from non-smokers (like “no smoking” sections in restaurants)‚ cleaning the air‚ and airing out buildings does not get rid of secondhand smoke. Other Ways Smoking Affects Others Smoking affects the people in your life ...
29 CFR 1910.28 - Safety requirements for scaffolding.
Code of Federal Regulations, 2010 CFR
2010-07-01
... least six times the intended load. (23) When acid solutions are used for cleaning buildings over 50 feet... of each corner with 1- by 6-inch gusset pieces. They shall also have braces 1 by 8 inches on both...
8 Things You Can Do to Protect Your Family from Secondhand Smoke
... smokers from nonsmokers (like "no smoking" sections in restaurants), cleaning the air, and airing out buildings does ... who do not smoke. Do not eat in restaurants that allow smoking. Do not take your child ...
OVERALL VIEW OF THE MILL WITH SUGAR BIN LEFT OF ...
OVERALL VIEW OF THE MILL WITH SUGAR BIN LEFT OF CENTER, CLEANING PLANT TO RIGHT, SEED TREATMENT PLANT TO LEFT. VIEW FROM THE EAST - Kekaha Sugar Company, Sugar Mill Building, 8315 Kekaha Road, Kekaha, Kauai County, HI
4. FIRST FLOOR SOUTH WALL, WITH PIPE MANIFOLDS AND (RIGHTCENTER) ...
4. FIRST FLOOR SOUTH WALL, WITH PIPE MANIFOLDS AND (RIGHT-CENTER) PORTABLE STEAM PUMP FOR PIPE MAINTENANCE AND CLEANING - Colgate & Company Jersey City Plant, Building No. B-3, 47-51 York Street, Jersey City, Hudson County, NJ
How to scientifically assess a restoration project: a case study
NASA Astrophysics Data System (ADS)
Alvarez de Buergo, M.; Fort, R.; Freire, D. M.; Lopez-Arce, P.; Vazquez-Calvo, C.
2012-04-01
Commonly, it is said that there is lack of communication among scientists, conservators, restorers, project managers and architects. But sometimes this communication flows, and we can find enormous benefits from and for all the participating agents. This is the case we present in this work, in which technical agents in charge of the restoration of a building, asked for some scientific advice to perform the restoration of a heritage building. The results were successful and fantastic for both of them, in terms of one part asking for consultation and the other answering to the demands and resolving real problems. This is the case of a marvellous Renaissance building (Medinaceli Dukes palace, 15th-16th centuries) in the central area of Spain (Cogolludo, Guadalajara). Focused on the restoration project, we were asked for consultancy on how to solve matters like the assessment of the already fixed in project cleaning method for the stone façades, the efficacy and durability methods for some conservation products to be applied, the presence or not of a patina on the stone; the viability of using some restoration mortars, and the origin of some efflorescences that came out just after placed in the building a restoration rendering mortar. Responses to these matters were answered by performing tests both in the lab and on site in the building. The efficiency and effects on stone of the blasting cleaning method was assessed by first analysing the nature and thickness of the surface deposits to be removed (SEM-EDS analyses); secondly, roughness and colour measurements were performed, and thirdly, SEM-EDS analyses were carried out again to determine whether the cleaning method was able to remove part of the surface deposits, completely, or even part of the stone substrate. Some conservation products were tested on stone specimens, both their efficacy and their durability, concluding that it was better not to apply any of them. A patina was found on the stone façade under SEM, probably applied for colouring and homogenizing purpose, and below it and on the stone, an acrylic film was analysed. It was in good state, and its removal could be worse and more dangerous to the substrate than leaving it. Two restoration mortars were tested to characterize them and to determine their durability, the results showing that one of them was much better than the other. Finally, a restoration render was analysed and we found, by analysing it and the raw materials used for its preparation, that one of them, a marketed cement, had a very high content on sulfates, responsible for the efflorescences (sulphate compounds) that appeared just after the render was placed in the building, this resulting on stopping using this product in the restoration project. Consequently, conservation science should be considered as not only useful but essential for cultural heritage conservation, besides it is cost-saving, because failed interventions are much more expensive in the short, medium and long term.
Precision Cleaning - Path to Premier
NASA Technical Reports Server (NTRS)
Mackler, Scott E.
2008-01-01
ITT Space Systems Division s new Precision Cleaning facility provides critical cleaning and packaging of aerospace flight hardware and optical payloads to meet customer performance requirements. The Precision Cleaning Path to Premier Project was a 2007 capital project and is a key element in the approved Premier Resource Management - Integrated Supply Chain Footprint Optimization Project. Formerly precision cleaning was located offsite in a leased building. A new facility equipped with modern precision cleaning equipment including advanced process analytical technology and improved capabilities was designed and built after outsourcing solutions were investigated and found lacking in ability to meet quality specifications and schedule needs. SSD cleans parts that can range in size from a single threaded fastener all the way up to large composite structures. Materials that can be processed include optics, composites, metals and various high performance coatings. We are required to provide verification to our customers that we have met their particulate and molecular cleanliness requirements and we have that analytical capability in this new facility. The new facility footprint is approximately half the size of the former leased operation and provides double the amount of throughput. Process improvements and new cleaning equipment are projected to increase 1st pass yield from 78% to 98% avoiding $300K+/yr in rework costs. Cost avoidance of $350K/yr will result from elimination of rent, IT services, transportation, and decreased utility costs. Savings due to reduced staff expected to net $4-500K/yr.
Schwendner, Petra; Moissl-Eichinger, Christine; Barczyk, Simon; Bohmeier, Maria; Pukall, Rüdiger; Rettberg, Petra
2013-12-01
In this study, samples from the spacecraft assembly clean room BAF (final assembly building), located at Centre Spatial Guyanais in Kourou, French Guiana, were characterized by qualitative and quantitative methods to determine the bioburden and biodiversity. The cultivation assays mainly focused on extremotolerant microorganisms that have special metabolic skills, such as the ability to grow without oxygen, fix nitrogen, grow autotrophically, or reduce sulfate. A broad range of media and growth conditions were used to simulate possible extraterrestrial environments and clean room buildings. In addition to these alternative cultivation assays, the ESA standard protocol for bioburden estimation was also applied. The phylogenetic analysis of the isolates (mainly facultative anaerobes) showed an extraordinarily broad cultivable biodiversity. Overall, 49 species were isolated and identified as members of the bacterial phyla Actinobacteria, Firmicutes, α-, β-, γ-Proteobacteria, and Bacteroidetes/Chlorobi. In addition to cultivation-based analyses, molecular techniques were also applied, including construction of a 16S rRNA gene clone library. The results indicate a wide-ranging microbial diversity (12 bacterial phyla, 34 families) that not only confirms the results of the cultivation efforts but also deepens our understanding of the noncultivable variety. Our investigations hint at a very broad, mainly uncultivated microbial diversity.
Impact of varying area of polluting surface materials on perceived air quality.
Sakr, W; Knudsen, H N; Gunnarsen, L; Haghighat, F
2003-06-01
A laboratory study was performed to investigate the impact of the concentration of pollutants in the air on emissions from building materials. Building materials were placed in ventilated test chambers. The experimental set-up allowed the concentration of pollution in the exhaust air to be changed either by diluting exhaust air with clean air (changing the dilution factor) or by varying the area of the material inside the chamber when keeping the ventilation rate constant (changing the area factor). Four different building materials and three combinations of two or three building materials were studied in ventilated small-scale test chambers. Each individual material and three of their combinations were examined at four different dilution factors and four different area factors. An untrained panel of 23 subjects assessed the air quality from the chambers. The results show that a certain increase in dilution improves the perceived air quality more than a similar decrease in area. The reason for this may be that the emission rate of odorous pollutants increases when the concentration in the chamber decreases. The results demonstrate that, in some cases the effect of increased ventilation on the air quality may be less than expected from a simple dilution model.
Building the Clean Energy Economy, Engaging the Private Sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2011-03-01
This packet provides a list of companies with whom EERE’s program offices collaborate. Below is a list of EERE’s program managers and their contact information should you or your organization be interested in pursuing opportunities with EERE.
DISPOSE OF WASTES, AN AID TO EXTENSION AND VILLAGE WORKERS IN MANY COUNTRIES.
ERIC Educational Resources Information Center
HUGHES, KATHRYNE S.
THE BOOKLET DESCRIBES IN DETAIL THE CORRECT METHODS OF DISPOSING OF WASTE MATERIALS, INCLUDING TRASH, GARBAGE, WASTE WATER, HUMAN EXCRETA, AND ANIMAL WASTES. COMPLETE INSTRUCTIONS FOR DIGGING, BUILDING, AND CLEANING ARE GIVEN UNDER EACH TOPIC. (CL)
Helping Foundations Build a Clean Energy Future | Working with Us | NREL
climate change globally deserve to be widely recognized and supported." -Sonia Medina, Director for Climate Change, Children's Investment Foundation Fund Photo of one man holding a small window outside with
1. Shown in the electric motor which powered the belts ...
1. Shown in the electric motor which powered the belts and drive shafts. This power system drove the tumblers which cleaned chain in building #7. - American Chain & Cable Company, East Princess Street (400 Block), York, York County, PA
NASA Astrophysics Data System (ADS)
Bay, Christopher Joseph
Massachusetts' Act to Promote Energy Diversity requires distribution companies to solicit contracts for up to 1600 MW of offshore wind. To test whether offshore wind projects can meet the Act's requirement to reduce C02 emissions, the Oak Ridge Competitive Electricity Dispatch Model was used to forecast changes in ISO New England's resource mix under five different wind capacity levels and calculate avoided C02 emissions attributable to offshore wind. With 1600 MW of installed capacity, representing full solicitation under the Act, reliance on natural gas is reduced by ˜10% and carbon emissions decline by ˜9%. This represents significant progress towards the goals of the Global Warming Solutions Act and the Clean Power Plan. The 5000 MW scenario reduces emissions enough to meet the Clean Power Plan's 2030 goals. This study's application of a dispatch model provides an example for policymakers of a simple and cost-effective approach for assessing a project's value.
Tohon, Zilahatou
2014-01-01
Objective. To assess the effect on health of the following measures in schools in Maradi (Niger): clean water supply, construction of latrines, establishment of hand washing stations, and health education. Methodology. It was a “before and after” intervention study on a sample of school children aged 7 to 12 years in the Maradi region. The interventions included building of latrines, supplying clean water, setting up hand washing stations, and teaching health education lessons. An individual questionnaire, analysis of stool samples, and a group questionnaire were administered to children and teachers, respectively. The threshold for significance was set at P < 0.05. Results. A statistically significant reduction in cases of diarrhoea and abdominal pains was noted after the project. Overall, carriage of at least one parasite increased from 7.5% before the project to 10.2% after it (P = 0.04). In the programme group schools, there was a statistically significant increase in the prevalence of Hymenolepis nana, from 0 to 1.9 (P = 0.02). Pinworm prevalence remained stable in this group but increased significantly in the control group. Conclusions. Putting health infrastructure in place in schools obviously had an impact on hygiene-related habits in the beneficiary schools and communities. PMID:24563779
Pickering, Ethan M; Hossain, Mohammad A; Mousseau, Jack P; Swanson, Rachel A; French, Roger H; Abramson, Alexis R
2017-01-01
Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and useful insights into building operation characteristics. A cross sectional analysis of six buildings in two different climate zones provides methods for data cleaning, population-based building comparisons, and relationships (correlations) of weather and electricity consumption. Data cleaning methods have been developed to categorize and appropriately filter or correct anomalous data including outliers, missing data, and erroneous values (resulting in < 0.5% anomalies). The utility of a cross-sectional analysis of a sample set of building's electricity consumption is found through comparisons of baseload, daily consumption variance, and energy use intensity. Correlations of weather and electricity consumption 15-minute interval datasets show important relationships for the heating and cooling seasons using computed correlations of a Time-Specific-Averaged-Ordered Variable (exterior temperature) and corresponding averaged variables (electricity consumption)(TSAOV method). The TSAOV method is unique as it introduces time of day as a third variable while also minimizing randomness in both correlated variables through averaging. This study found that many of the pair-wise linear correlation analyses lacked strong relationships, prompting the development of the new TSAOV method to uncover the causal relationship between electricity and weather. We conclude that a combination of varied HVAC system operations, building thermal mass, plug load use, and building set point temperatures are likely responsible for the poor correlations in the prior studies, while the correlation of time-specific-averaged-ordered temperature and corresponding averaged variables method developed herein adequately accounts for these issues and enables discovery of strong linear pair-wise correlation R values. TSAOV correlations lay the foundation for a new approach to building studies, that mitigates plug load interferences and identifies more accurate insights into weather-energy relationship for all building types. Over all six buildings analyzed the TSAOV method reported very significant average correlations per building of 0.94 to 0.82 in magnitude. Our rigorous statistics-based methods applied to 15-minute-interval electricity data further enables virtual energy audits of buildings to quickly and inexpensively inform energy savings measures.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pickering, Ethan M.; Hossain, Mohammad A.; Mousseau, Jack P.
Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and useful insights into building operation characteristics. A cross sectional analysis of six buildings in two different climate zones provides methods for data cleaning, population-based building comparisons, and relationships (correlations) of weather and electricity consumption. Data cleaning methods have been developed to categorize and appropriately filter or correct anomalous data including outliers, missing data, and erroneous values (resulting in < 0.5% anomalies). Themore » utility of a cross-sectional analysis of a sample set of building's electricity consumption is found through comparisons of baseload, daily consumption variance, and energy use intensity. Correlations of weather and electricity consumption 15-minute interval datasets show important relationships for the heating and cooling seasons using computed correlations of a Time-Specific-Averaged- Ordered Variable (exterior temperature) and corresponding averaged variables (electricity consumption)(TSAOV method). The TSAOV method is unique as it introduces time of day as a third variable while also minimizing randomness in both correlated variables through averaging. This study found that many of the pair-wise linear correlation analyses lacked strong relationships, prompting the development of the new TSAOV method to uncover the causal relationship between electricity and weather. We conclude that a combination of varied HVAC system operations, building thermal mass, plug load use, and building set point temperatures are likely responsible for the poor correlations in the prior studies, while the correlation of time-specific-averaged-ordered temperature and corresponding averaged variables method developed herein adequately accounts for these issues and enables discovery of strong linear pair-wise correlation R values. TSAOV correlations lay the foundation for a new approach to building studies, that mitigates plug load interferences and identifies more accurate insights into weather-energy relationship for all building types. Over all six buildings analyzed the TSAOV method reported very significant average correlations per building of 0.94 to 0.82 in magnitude. Our rigorous statistics-based methods applied to 15- minute-interval electricity data further enables virtual energy audits of buildings to quickly and inexpensively inform energy savings measures.« less
Pickering, Ethan M.; Hossain, Mohammad A.; Mousseau, Jack P.; ...
2017-10-31
Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and useful insights into building operation characteristics. A cross sectional analysis of six buildings in two different climate zones provides methods for data cleaning, population-based building comparisons, and relationships (correlations) of weather and electricity consumption. Data cleaning methods have been developed to categorize and appropriately filter or correct anomalous data including outliers, missing data, and erroneous values (resulting in < 0.5% anomalies). Themore » utility of a cross-sectional analysis of a sample set of building's electricity consumption is found through comparisons of baseload, daily consumption variance, and energy use intensity. Correlations of weather and electricity consumption 15-minute interval datasets show important relationships for the heating and cooling seasons using computed correlations of a Time-Specific-Averaged- Ordered Variable (exterior temperature) and corresponding averaged variables (electricity consumption)(TSAOV method). The TSAOV method is unique as it introduces time of day as a third variable while also minimizing randomness in both correlated variables through averaging. This study found that many of the pair-wise linear correlation analyses lacked strong relationships, prompting the development of the new TSAOV method to uncover the causal relationship between electricity and weather. We conclude that a combination of varied HVAC system operations, building thermal mass, plug load use, and building set point temperatures are likely responsible for the poor correlations in the prior studies, while the correlation of time-specific-averaged-ordered temperature and corresponding averaged variables method developed herein adequately accounts for these issues and enables discovery of strong linear pair-wise correlation R values. TSAOV correlations lay the foundation for a new approach to building studies, that mitigates plug load interferences and identifies more accurate insights into weather-energy relationship for all building types. Over all six buildings analyzed the TSAOV method reported very significant average correlations per building of 0.94 to 0.82 in magnitude. Our rigorous statistics-based methods applied to 15- minute-interval electricity data further enables virtual energy audits of buildings to quickly and inexpensively inform energy savings measures.« less
Building a Clean Energy Future for Power Production | Working with Us |
Rice Brent Rice EXECUTIVE MANAGER, STRATEGIC PARTNERSHIPS Email me Photo of a man and a woman stand Partnership Successes Photo of a man and a woman stand next to a gas storage tank and bioreactor. Partnering
Energy 101: Fuel Cell Technology
None
2018-05-30
Learn how fuel cell technology generates clean electricity from hydrogen to power our buildings and transportation-while emitting nothing but water. This video illustrates the fundamentals of fuel cell technology and its potential to supply our homes, offices, industries, and vehicles with sustainable, reliable energy.
Helping the U.S. Federal Government Build a Clean Energy Future | Working
a mesa on dark soil, surrounded by scorched foliage Explore our partnership successes Explore Now à Close Partnership Successes Photo of a woman standing atop a mesa on dark soil, surrounded by scorched
Chemical Accident Prevention - Chemicals in your Community
This pamphlet summarizes the information you can obtain under Emergency Planning and Community Right-to-Know and Clean Air Act, how you can use these sources to build a snapshot of chemicals stored and released, and how SERCs and LEPCs can improve safety.
INTERIOR, ROOF, A view looking southwest through Room 205 at ...
INTERIOR, ROOF, A view looking southwest through Room 205 at the doorway that leads to Room 206P, a shower and clean area in the penthouse - Department of Energy, Mound Facility, B Building, One Mound Road, Miamisburg, Montgomery County, OH
Helping the Defense Sector Build a Clean Energy Future | Working with Us |
Laboratory Program Manager, Partnership Development Email me Photo of a male and female researcher in a lab a male and female researcher in a lab working on a machine Helping to Solve the Army's Refueling
Air cleaning technologies: an evidence-based analysis.
2005-01-01
This health technology policy assessment will answer the following questions: When should in-room air cleaners be used?How effective are in-room air cleaners?Are in-room air cleaners that use combined HEPA and UVGI air cleaning technology more effective than those that use HEPA filtration alone?What is the Plasmacluster ion air purifier in the pandemic influenza preparation plan?The experience of severe acute respiratory syndrome (SARS) locally, nationally, and internationally underscored the importance of administrative, environmental, and personal protective infection control measures in health care facilities. In the aftermath of the SARS crisis, there was a need for a clearer understanding of Ontario's capacity to manage suspected or confirmed cases of airborne infectious diseases. In so doing, the Walker Commission thought that more attention should be paid to the potential use of new technologies such as in-room air cleaning units. It recommended that the Medical Advisory Secretariat of the Ontario Ministry of Health and Long-Term Care evaluate the appropriate use and effectiveness of such new technologies. Accordingly, the Ontario Health Technology Advisory Committee asked the Medical Advisory Secretariat to review the literature on the effectiveness and utility of in-room air cleaners that use high-efficiency particle air (HEPA) filters and ultraviolet germicidal irradiation (UVGI) air cleaning technology. Additionally, the Ontario Health Technology Advisory Committee prioritized a request from the ministry's Emergency Management Unit to investigate the possible role of the Plasmacluster ion air purifier manufactured by Sharp Electronics Corporation, in the pandemic influenza preparation plan. Airborne transmission of infectious diseases depends in part on the concentration of breathable infectious pathogens (germs) in room air. Infection control is achieved by a combination of administrative, engineering, and personal protection methods. Engineering methods that are usually carried out by the building's heating, ventilation, and air conditioning (HVAC) system function to prevent the spread of airborne infectious pathogens by diluting (dilution ventilation) and removing (exhaust ventilation) contaminated air from a room, controlling the direction of airflow and the air flow patterns in a building. However, general wear and tear over time may compromise the HVAC system's effectiveness to maintain adequate indoor air quality. Likewise, economic issues may curtail the completion of necessary renovations to increase its effectiveness. Therefore, when exposure to airborne infectious pathogens is a risk, the use of an in-room air cleaner to reduce the concentration of airborne pathogens and prevent the spread of airborne infectious diseases has been proposed as an alternative to renovating a HVAC system. Airborne transmission is the spread of infectious pathogens over large distances through the air. Infectious pathogens, which may include fungi, bacteria, and viruses, vary in size and can be dispersed into the air in drops of moisture after coughing or sneezing. Small drops of moisture carrying infectious pathogens are called droplet nuclei. Droplet nuclei are about 1 to 5μm in diameter. This small size in part allows them to remain suspended in the air for several hours and be carried by air currents over considerable distances. Large drops of moisture carrying infectious pathogens are called droplets. Droplets being larger than droplet nuclei, travel shorter distances (about 1 metre) before rapidly falling out of the air to the ground. Because droplet nuclei remain airborne for longer periods than do droplets, they are more amenable to engineering infection control methods than are droplets. Droplet nuclei are responsible for the airborne transmission of infectious diseases such as tuberculosis, chicken pox (varicella), measles (rubeola), and dessiminated herpes zoster, whereas close contact is required for the direct transmission of infectious diseases transmitted by droplets, such as influenza (the flu) and SARS. In-room air cleaners are supplied as portable or fixed devices. Fixed devices can be attached to either a wall or ceiling and are preferred over portable units because they have a greater degree of reliability (if installed properly) for achieving adequate room air mixing and airflow patterns, which are important for optimal effectiveness. Through a method of air recirculation, an in-room air cleaner can be used to increase room ventilation rates and if used to exhaust air out of the room it can create a negative-pressure room for airborne infection isolation (AII) when the building's HVAC system cannot do so. A negative-pressure room is one where clean air flows into the room but contaminated air does not flow out of it. Contaminated room air is pulled into the in-room air cleaner and cleaned by passing through a series of filters, which remove the airborne infectious pathogens. The cleaned air is either recirculated into the room or exhausted outside the building. By filtering contaminated room air and then recirculating the cleaned air into the room, an in-room air cleaner can improve the room's ventilation. By exhausting the filtered air to the outside the unit can create a negative-pressure room. There are many types of in-room air cleaners. They vary widely in the airflow rates through the unit, the type of air cleaning technology used, and the technical design. Crucial to maximizing the efficiency of any in-room air cleaner is its strategic placement and set-up within a room, which should be done in consultation with ventilation engineers, infection control experts, and/or industrial hygienists. A poorly positioned air cleaner may disrupt airflow patterns within the room and through the air cleaner, thereby compromising its air cleaning efficiency. The effectiveness of an in-room air cleaner to remove airborne pathogens from room air depends on several factors, including the airflow rate through the unit's filter and the airflow patterns in the room. Tested under a variety of conditions, in-room air cleaners, including portable or ceiling mounted units with either a HEPA or a non-HEPA filter, portable units with UVGI lights only, or ceiling mounted units with combined HEPA filtration and UVGI lights, have been estimated to be between 30% and 90%, 99% and 12% and 80% effective, respectively. However, and although their effectiveness is variable, the United States Centers for Disease Control and Prevention has acknowledged in-room air cleaners as alternative technology for increasing room ventilation when this cannot be achieved by the building's HVAC system with preference given to fixed recirculating systems over portable ones. Importantly, the use of an in-room air cleaner does not preclude either the need for health care workers and visitors to use personal protective equipment (N95 mask or equivalent) when entering AII rooms or health care facilities from meeting current regulatory requirements for airflow rates (ventilation rates) in buildings and airflow differentials for effective negative-pressure rooms. The Plasmacluster ion technology, developed in 2000, is an air purification technology. Its manufacturer, Sharp Electronics Corporation, says that it can disable airborne microorganisms through the generation of both positive and negative ions. (1) The functional unit is the hydroxyl, which is a molecule comprised of one oxygen molecule and one hydrogen atom. Plasmacluster ion air purifier uses a multilayer filter system composed of a prefilter, a carbon filter, an antibacterial filter, and a HEPA filter, combined with an ion generator to purify the air. The ion generator uses an alternating plasma discharge to split water molecules into positively and negatively charged ions. When these ions are emitted into the air, they are surrounded by water molecules and form cluster ions which are attracted to airborne particles. The cluster ion surrounds the airborne particle, and the positive and negative ions react to form hydroxyls. These hydroxyls steal the airborne particle's hydrogen atom, which creates a hole in the particle's outer protein membrane, thereby rendering it inactive. Because influenza is primarily acquired by large droplets and direct and indirect contact with an infectious person, any in-room air cleaner will have little benefit in controlling and preventing its spread. Therefore, there is no role for the Plasmacluster ion air purifier or any other in-room air cleaner in the control of the spread of influenza. Accordingly, for purposes of this review, the Medical Advisory Secretariat presents no further analysis of the Plasmacluster. The objective of the systematic review was to determine the effectiveness of in-room air cleaners with built in UVGI lights and HEPA filtration compared with those using HEPA filtration only. The Medical Advisory Secretariat searched the databases of MEDLINE, EMBASE, Cochrane Database of Systematic Reviews, INAHATA (International Network of Agencies for Health Technology Assessment), Biosis Previews, Bacteriology Abstracts, Web of Science, Dissertation Abstracts, and NIOSHTIC 2. A meta-analysis was conducted if adequate data was available from 2 or more studies and where statistical and clinical heterogeneity among studies was not an issue. Otherwise, a qualitative review was completed. The GRADE system was used to summarize the quality of the body of evidence comprised of 1 or more studies. There were no existing health technology assessments on air cleaning technology located during the literature review. The literature search yielded 59 citations of which none were retained. (ABSTRACT TRUNCATED)
Hossain, Mohammad A.; Mousseau, Jack P.; Swanson, Rachel A.; French, Roger H.; Abramson, Alexis R.
2017-01-01
Current approaches to building efficiency diagnoses include conventional energy audit techniques that can be expensive and time consuming. In contrast, virtual energy audits of readily available 15-minute-interval building electricity consumption are being explored to provide quick, inexpensive, and useful insights into building operation characteristics. A cross sectional analysis of six buildings in two different climate zones provides methods for data cleaning, population-based building comparisons, and relationships (correlations) of weather and electricity consumption. Data cleaning methods have been developed to categorize and appropriately filter or correct anomalous data including outliers, missing data, and erroneous values (resulting in < 0.5% anomalies). The utility of a cross-sectional analysis of a sample set of building’s electricity consumption is found through comparisons of baseload, daily consumption variance, and energy use intensity. Correlations of weather and electricity consumption 15-minute interval datasets show important relationships for the heating and cooling seasons using computed correlations of a Time-Specific-Averaged-Ordered Variable (exterior temperature) and corresponding averaged variables (electricity consumption)(TSAOV method). The TSAOV method is unique as it introduces time of day as a third variable while also minimizing randomness in both correlated variables through averaging. This study found that many of the pair-wise linear correlation analyses lacked strong relationships, prompting the development of the new TSAOV method to uncover the causal relationship between electricity and weather. We conclude that a combination of varied HVAC system operations, building thermal mass, plug load use, and building set point temperatures are likely responsible for the poor correlations in the prior studies, while the correlation of time-specific-averaged-ordered temperature and corresponding averaged variables method developed herein adequately accounts for these issues and enables discovery of strong linear pair-wise correlation R values. TSAOV correlations lay the foundation for a new approach to building studies, that mitigates plug load interferences and identifies more accurate insights into weather-energy relationship for all building types. Over all six buildings analyzed the TSAOV method reported very significant average correlations per building of 0.94 to 0.82 in magnitude. Our rigorous statistics-based methods applied to 15-minute-interval electricity data further enables virtual energy audits of buildings to quickly and inexpensively inform energy savings measures. PMID:29088269
Elements That Contribute to Healthy Building Design
Loftness, Vivian; Hakkinen, Bert; Adan, Olaf; Nevalainen, Aino
2007-01-01
Background The elements that contribute to a healthy building are multifactorial and can be discussed from different perspectives. Objectives We present three viewpoints of designing a healthy building: the importance of sustainable development, the role of occupants for ensuring indoor air quality, and ongoing developments related to indoor finishes with low chemical emissions and good fungal resistance. Discussion Sustainable design rediscovers the social, environmental, and technical values of pedestrian and mixed-use communities, using existing infrastructures including “main streets” and small-town planning principles and recapturing indoor–outdoor relationships. This type of design introduces nonpolluting materials and assemblies with lower energy requirements and higher durability and recyclability. Building occupants play a major role in maintaining healthy indoor environments, especially in residences. Contributors to indoor air quality include cleaning habits and other behaviors; consumer products, furnishings, and appliances purchases, as well as where and how the occupants use them. Certification of consumer products and building materials as low-emitting products is a primary control measure for achieving good indoor air quality. Key products in this respect are office furniture, flooring, paints and coatings, adhesives and sealants, wall coverings, wood products, textiles, insulation, and cleaning products. Finishing materials play a major role in the quality of indoor air as related to moisture retention and mold growth. Conclusions Sustainable design emphasizes the needs of infrastructure, lower energy consumption, durability, and recyclability. To ensure good indoor air quality, the product development for household use should aim to reduce material susceptibility to contaminants such as mold and should adopt consumer-oriented product labeling. PMID:17589608
Lessons Learned from Decontamination Experiences
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sorensen, JH
2000-11-16
This interim report describes a DOE project currently underway to establish what is known about decontamination of buildings and people and the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who weremore » decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.« less
Blades of Glory: An Energy.gov Mini-Doc â The 2016 Collegiate Wind Competition
Zayas, Jose; Newcomb, Charles
2018-01-16
In this short documentary, we follow three collegiate teams who are participating in this yearâs U.S. Department of Energy Collegiate Wind Competition in New Orleans. Learn about their experiences and why the competition is important for Americaâs clean energy future. The competition provides undergraduates with real-world skills they need to enter tomorrowâs clean energy workforce by challenging them to develop and deliver a business plan, establish a deployment strategy, and build and test a wind turbine.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, Lockheed Martin technicians begin to move the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) to a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA's Kennedy Space Center in Florida, Lockheed Martin technicians secure a protective cover around the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) for its move to a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, a Lockheed Martin technician secures a protective cover around the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) for its move to a clean room The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, Lockheed Martin technicians secure a protective cover around the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) for its move to a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, a protective cover is installed around the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) for its move to a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, Lockheed Martin technicians are preparing the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) for the move into a clean room. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA's Kennedy Space Center in Florida, Lockheed Martin technicians secure a protective cover around the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) for its move to a clean. The CMA will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
Orion EM-1 Crew Module Adapter Move to Clean Room
2016-11-29
Inside the Neil Armstrong Operations and Checkout Building high bay at NASA’s Kennedy Space Center in Florida, the Orion crew module adapter (CMA) for Exploration Mission 1 (EM-1) is in a clean room with protective walls secured around it. The adapter will undergo propellant and environmental control and life support system tube installation and welding. The adapter will connect the Orion crew module to the European Space Agency-provided service module. The Orion spacecraft will launch atop NASA’s Space Launch System rocket on EM-1, its first deep space mission, in late 2018.
VIEW OF THE INTERIOR OF BUILDING 125, THE STANDARDS LABORATORY. ...
VIEW OF THE INTERIOR OF BUILDING 125, THE STANDARDS LABORATORY. THE PRIMARY FUNCTION OF THE STANDARDS LABORATORY WAS TO ENSURE AND IMPLEMENT A SYSTEM OF QUALITY CONTROL FOR INCOMING MATERIALS USED IN MANUFACTURING PROCESSES. SEVERAL ENGINEERING CONTROLS WERE USED TO ASSURE ACCURACY OF THE CALIBRATION PROCESSES INCLUDING: FLEX-FREE GRANITE TABLES, AIR LOCKED DOORS, TEMPERATURE CONTROLS, AND A SUPER-CLEAN ENVIRONMENT - Rocky Flats Plant, Standards Laboratory, Immediately north of 215A water tower & adjacent to Third Street, Golden, Jefferson County, CO
[Effect of manual cleaning and machine cleaning for dental handpiece].
Zhou, Xiaoli; Huang, Hao; He, Xiaoyan; Chen, Hui; Zhou, Xiaoying
2013-08-01
Comparing the dental handpiece' s cleaning effect between manual cleaning and machine cleaning. Eighty same contaminated dental handpieces were randomly divided into experimental group and control group, each group contains 40 pieces. The experimental group was treated by full automatic washing machine, and the control group was cleaned manually. The cleaning method was conducted according to the operations process standard, then ATP bioluminescence was used to test the cleaning results. Average relative light units (RLU) by ATP bioluminescence detection were as follows: Experimental group was 9, control group was 41. The two groups were less than the recommended RLU value provided by the instrument manufacturer (RLU < or = 45). There was significant difference between the two groups (P < 0.05). The cleaning quality of the experimental group was better than that of control group. It is recommended that the central sterile supply department should clean dental handpieces by machine to ensure the cleaning effect and maintain the quality.
Summary of human responses to ventilation.
Seppänen, O A; Fisk, W J
2004-01-01
It is known that ventilation is necessary to remove indoor-generated pollutants from indoor air or dilute their concentration to acceptable levels. But as the limit values of all pollutants are not known the exact determination of required ventilation rates based on pollutant concentrations is seldom possible. The selection of ventilation rates has to be based also on epidemiological research, laboratory and field experiments and experience. The existing literature indicates that ventilation has a significant impact on several important human outcomes including: (1) communicable respiratory illnesses; (2) sick building syndrome symptoms; (3) task performance and productivity, and (4) perceived air quality (PAQ) among occupants or sensory panels (5) respiratory allergies and asthma. In many studies, prevalence of sick building syndrome symptoms has also been associated with characteristics of HVAC-systems. Often the prevalence of SBS symptoms is higher in air-conditioned buildings than in naturally ventilated buildings. The evidence suggests that better hygiene, commissioning, operation and maintenance of air handling systems may be particularly important for reducing the negative effects of HVAC systems. Ventilation may also have harmful effects on indoor air quality and climate if not properly designed, installed, maintained and operated. Ventilation may bring indoors harmful substances or deteriorate indoor environment. Ventilation interacts also with the building envelope and may deteriorate the structures of the building. Ventilation changes the pressure differences across the structures of building and may cause or prevent infiltration of pollutants from structures or adjacent spaces. Ventilation is also in many cases used to control the thermal environment or humidity in buildings. The paper summarises the current knowledge on positive and negative effects of ventilation on health and other human responses. The focus is on office-type working environment and residential buildings. The review shows that ventilation has various positive impacts on health and productivity of building occupants. Ventilation reduces the prevalence of airborne infectious diseases and thus the number of sick leave days. In office environment a ventilation rate up to 20-25 L/s per person seem to decrease the prevalence of SBS-symptoms. Air conditioning systems may increase the prevalence of SBS-symptoms relative to natural ventilation if not clean. In residential buildings the air change rate in cold climates should not be below app. 0.5 ach. Ventilation systems may cause pressure differences over the building envelope and bring harmful pollutants indoors.
Hawkins, Steve A C; Simmons, Hugh A; Gough, Kevin C; Maddison, Ben C
2015-01-24
Scrapie of sheep/goats and chronic wasting disease of deer/elk are contagious prion diseases where environmental reservoirs are directly implicated in the transmission of disease. In this study, the effectiveness of recommended scrapie farm decontamination regimens was evaluated by a sheep bioassay using buildings naturally contaminated with scrapie. Pens within a farm building were treated with either 20,000 parts per million free chorine solution for one hour or were treated with the same but were followed by painting and full re-galvanisation or replacement of metalwork within the pen. Scrapie susceptible lambs of the PRNP genotype VRQ/VRQ were reared within these pens and their scrapie status was monitored by recto-anal mucosa-associated lymphoid tissue. All animals became infected over an 18-month period, even in the pen that had been subject to the most stringent decontamination process. These data suggest that recommended current guidelines for the decontamination of farm buildings following outbreaks of scrapie do little to reduce the titre of infectious scrapie material and that environmental recontamination could also be an issue associated with these premises. British Veterinary Association.
In Search for Sustainable Coastal Management: A Case Study of Semarang, Indonesia
NASA Astrophysics Data System (ADS)
Hadi, Sudharto P.
2017-02-01
As a coastal town, Semarang is currently facing environmental problems such as flood, tidal flood (locally called rob), coastal abrasion, emerging land, land subsidence and sea water intrusion. These phenomena severely affect to citizen, community and corporate, disrupting day to day activities, threatening people’s health, causing economics’ burden and reducing property value. Government policies in dealing with these problem are focused on its phenomena such as normalizing river for flood and building polder systems for tidal flood. Impacted people have been implementing various initiatives. People in Tanah Mas Estate set up collective efforts to reduce tidal flood by building pumping system project, while people in Kampong Tambaklorok conduct a regular mutual assistance in cleaning of waste and sedimentation, rehabilitating of local drainages and dikes, reconstructing of local streets and also maintaining of pumping system. People in Mangunharjo, the district of Tugu build a coastal belt and cultivate mangrove. Various government and local initiatives have been effective in dealing with flood and tidal flood temporarily. More comprehensive approaches and focused on the sources of problems are required to achieve sustainable coastal management.
Recycling of rubble from building demolition for low-shrinkage concretes.
Corinaldesi, Valeria; Moriconi, Giacomo
2010-04-01
In this project concrete mixtures were prepared that were characterized by low ductility due to desiccation by using debris from building demolition, which after a suitable treatment was used as aggregate for partial replacement of natural aggregates. The recycled aggregate used came from a recycling plant, in which rubble from building demolition was selected, crushed, cleaned, sieved, and graded. Such aggregates are known to be more porous as indicated by the Saturated Surface Dry (SSD) moisture content. The recycled concrete used as aggregates were added to the concrete mixture in order to study their influence on the fresh and hardened concrete properties. They were added either after water pre-soaking or in dry condition, in order to evaluate the influence of moisture in aggregates on the performance of concrete containing recycled aggregate. In particular, the effect of internal curing, due to the use of such aggregates, was studied. Concrete behavior due to desiccation under dehydration was studied by means of both drying shrinkage test and German angle test, through which shrinkage under the restrained condition of early age concrete can be evaluated. Copyright 2009 Elsevier Ltd. All rights reserved.
Final Report. Solar Assist for Administration Building and Community Gym/Pool
DOE Office of Scientific and Technical Information (OSTI.GOV)
Synder, Randy; Bresette, Joseph
2015-06-23
Tonto Apache Tribe applied to the Department of Energy’s “Tribal Energy Program” for the “Community Scale Clean Energy Projects” in Indian Country in 2013 to implement a solar project to reduce energy use in two tribal buildings. Total estimated project cost was $804,140, with the Department and Tribe each providing 50% of the project costs. Photovoltaic systems totaling 75 kW on the Administration Building and 192 kW on the Gymnasium were installed. We used roof tops and installed canopies in adjacent parking areas for mounting the systems. The installed systems were designed to offset 65% of the facilities electric load.
Green, Clean, & Mean: Pushing the Energy Envelope in Tech Industry Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mills, Evan; Granderson, Jessica; Chan, Rengie
When it comes to innovation in energy and building performance, one can expect leading-edge activity from the technology sector. As front-line innovators in design, materials science, and information management, developing and operating high-performance buildings is a natural extension of their core business. The energy choices made by technology companies have broad importance given their influence on society at large as well as the extent of their own energy footprint. Microsoft, for example, has approximately 250 facilities around the world (30 million square feet of floor area), with significant aggregate energy use of approximately 4 million kilowatt-hours per day (Figure 1).
Clean Up Your School Custodial Program.
ERIC Educational Resources Information Center
Steller, Arthur W.; Pell, Carroll
1986-01-01
Administrators can improve their school's custodial program by following steps that increase productivity, reduce costs, and provide long-term benefits of higher cleanliness standards. Administrators should work toward improved building cleanliness by insisting on a school board policy that establishes objectives for the custodial department.…
7. GENERAL VIEW OF GUT SHANTY ON LEVEL 3; LOOKING ...
7. GENERAL VIEW OF GUT SHANTY ON LEVEL 3; LOOKING SOUTHEAST; HOG VISCERA WERE SORTED AND CLEANED WITH HOT WATER ON LONG STAINLESS STEEL TABLES - Rath Packing Company, Hog Dressing Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
ERIC Educational Resources Information Center
Post Office Dept., Washington, DC.
Guidelines, methods and policies regarding the care and maintenance of post office building floors are overviewed in this handbook. Procedures outlined are concerned with maintaining a required level of appearance without wasting manpower. Flooring types and characteristics and the particular cleaning requirements of each type are given along with…
ERIC Educational Resources Information Center
Kennedy, Mike
2010-01-01
Many education institutions have embraced the growing push for sustainable design and have built environmentally friendly facilities that use resources more efficiently. But the plaudits that administrators receive for LEED certification and other recognition of their efforts may be meaningless if the green commitment ends when a building is…
Code of Federal Regulations, 2014 CFR
2014-01-01
..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...
Code of Federal Regulations, 2010 CFR
2010-01-01
..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...
Code of Federal Regulations, 2011 CFR
2011-01-01
..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...
Code of Federal Regulations, 2012 CFR
2012-01-01
..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...
Code of Federal Regulations, 2013 CFR
2013-01-01
..., manufactured, handled, packaged or stored (except dry storage of packaged finished products and supplies) or in... materials not regularly used. (1) Coolers and freezers. Coolers and freezers where dairy products are stored shall be clean, reasonably dry and maintained at the proper uniform temperature and humidity to...
Chargemaster maintenance: think 'spring cleaning' all year round.
Barton, Shawn; Lancaster, Dani; Bieker, Mike
2008-11-01
Steps toward maintaining a standardized chargemaster include: Building a corporate chargemaster maintenance team. Developing a core research function. Designating hospital liaisons. Publishing timely reports on facility compliance. Using system codes to identify charges. Selecting chargemaster maintenance software. Developing a standard chargemaster data repository. Educating staff.
ERIC Educational Resources Information Center
Crawford, Gary N.
1995-01-01
Planning new construction is an opportunity to recognize indoor environmental quality (IEQ) issues. Provides an overview of some common IEQ issues associated with construction projects. A building's heating, ventilating, and air-conditioning (HVAC) system is by far the single most common cause of IEQ problems and complaints. (MLF)
Minimizing residues and strain in 2D materials transferred from PDMS.
Jain, Achint; Bharadwaj, Palash; Heeg, Sebastian; Parzefall, Markus; Taniguchi, Takashi; Watanabe, Kenji; Novotny, Lukas
2018-06-29
Integrating layered two-dimensional (2D) materials into 3D heterostructures offers opportunities for novel material functionalities and applications in electronics and photonics. In order to build the highest quality heterostructures, it is crucial to preserve the cleanliness and morphology of 2D material surfaces that come in contact with polymers such as PDMS during transfer. Here we report that substantial residues and up to ∼0.22% compressive strain can be present in monolayer MoS 2 transferred using PDMS. We show that a UV-ozone pre-cleaning of the PDMS surface before exfoliation significantly reduces organic residues on transferred MoS 2 flakes. An additional 200 ◦ C vacuum anneal after transfer efficiently removes interfacial bubbles and wrinkles as well as accumulated strain, thereby restoring the surface morphology of transferred flakes to their native state. Our recipe is important for building clean heterostructures of 2D materials and increasing the reproducibility and reliability of devices based on them.
Minimizing residues and strain in 2D materials transferred from PDMS
NASA Astrophysics Data System (ADS)
Jain, Achint; Bharadwaj, Palash; Heeg, Sebastian; Parzefall, Markus; Taniguchi, Takashi; Watanabe, Kenji; Novotny, Lukas
2018-06-01
Integrating layered two-dimensional (2D) materials into 3D heterostructures offers opportunities for novel material functionalities and applications in electronics and photonics. In order to build the highest quality heterostructures, it is crucial to preserve the cleanliness and morphology of 2D material surfaces that come in contact with polymers such as PDMS during transfer. Here we report that substantial residues and up to ∼0.22% compressive strain can be present in monolayer MoS2 transferred using PDMS. We show that a UV-ozone pre-cleaning of the PDMS surface before exfoliation significantly reduces organic residues on transferred MoS2 flakes. An additional 200 ◦C vacuum anneal after transfer efficiently removes interfacial bubbles and wrinkles as well as accumulated strain, thereby restoring the surface morphology of transferred flakes to their native state. Our recipe is important for building clean heterostructures of 2D materials and increasing the reproducibility and reliability of devices based on them.
Lam, K S; Chan, F S; Fung, W Y; Lui, B S S; Lau, L W L
2006-04-01
A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.
NASA Astrophysics Data System (ADS)
Feng, Xiaobing; Pascal, Jonathan; Lawes, Simon
2017-09-01
During the process of measurement using a micro-coordinate measurement machine (µCMM) contamination gradually builds up on the surface of the stylus tip and affects the dimensional accuracy of the measurement. Regular inspection of the stylus for contamination is essential to determine the appropriate cleaning interval and prevent the dimensional error from becoming significant. However, in situ inspection of a µCMM stylus is challenging due to the size, spherical shape, material and surface properties of a typical stylus. To address this challenge, this study evaluates several non-contact measurement technologies for in situ stylus inspection and, based on those findings, proposes a cost-effective microscopy approach. The operational principle is then demonstrated by an automated prototype, coordinated directly by the CMM software MCOSMOS, with an effective threshold of detection as low as 400 nm and a large field of view and depth of field. The level of contamination on the stylus has been found to increase steadily with the number of measurement contacts made. Once excessive contamination is detected on the stylus, measurement should be stopped and a stylus cleaning procedure should be performed to avoid affecting measurement accuracy.
NASA Astrophysics Data System (ADS)
Włodarski, Marcin; Martyniuk-Pęczek, Justyna
2017-10-01
Recent years, the European Environmental Agency, has been reporting air quality parameters in Poland, as the poorest among all the EU countries. Despite of adoption of the EU legislation on energy efficiency and energy performance of buildings, existing legal solutions occur insufficient in reducing air pollution in Polish regions. Lack of an effective schemes supporting complex thermal renovation of buildings, exchange of inefficient boilers, developing district heating based on clean and renewable fuels results in severe health problems and 40 000 of premature deaths related to air pollution. Availability of the EU structural funds may become a tremendous opportunity, especially for the residential sector, to conduct a massive scale modernization. Nevertheless, lack of a coordinated action involving all levels of governance may put the opportunity at risk. The article aims to answer the question on the readiness of the regional governments to effectively implement energy efficiency measures mitigating the problem of air pollution. Second objective is to analyse whether the Regional Operational Programmes allocating the ERDF funds to support specific development needs of the regions, have been constructed in a way that properly addresses the problems related to energy performance of residential buildings.
Use of rubble from building demolition in mortars.
Corinaldesi, V; Giuggiolini, M; Moriconi, G
2002-01-01
Because of increasing waste production and public concerns about the environment, it is desirable to recycle materials from building demolition. If suitably selected, ground, cleaned and sieved in appropriate industrial crushing plants, these materials can be profitably used in concrete. Nevertheless, the presence of masonry instead of concrete rubble is particularly detrimental to the mechanical performance and durability of recycled-aggregate concrete and the same negative effect is detectable when natural sand is replaced by fine recycled aggregate fraction. An alternative use of both masonry rubble and fine recycled material fraction could be in mortars. These could contain either recycled instead of natural sand or powder obtained by bricks crushing as partial cement substitution. In particular, attention is focused on the modification that takes place when either polypropylene or stainless steel fibers are added to these mortars. Polypropylene fibers are added in order to reduce shrinkage of mortars, stainless steel fibers for improving their flexural strength. The combined use of polypropylene fibers and fine recycled material from building demolition could allow the preparation of mortars showing good performance, in particular when coupled with bricks. Furthermore, the combined use of stainless steel fibers and mortars containing brick powder seems to be an effective way to guarantee a high flexural strength.
Toxic Chemical Exposure in Schools: Our Children at Risk.
ERIC Educational Resources Information Center
Sterling, Peter; Paquette, Nicole
Asserting that toxic chemicals can be found throughout school grounds in pesticides, building materials, school supplies, cleaning products, office equipment, and personal care products, this reports details the prevalence of toxic chemicals within schools and recommends methods for reducing exposure. Following an executive summary, the report…
78 FR 34350 - Procurement List; Proposed Additions and Deletions
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-07
... Tinker Air Force Base as aggregated by the Oklahoma City Air Logistics Center (FA8126 AFSC PZIMB), Tinker... Affairs National Acquisition Center, Hines, IL. NSN: 7920-00-NIB-0564--Towel, Cleaning, Non-woven... Activity: General Services Administration, Public Buildings Service, Potomac Service Center, Washington, DC...
Oregon Custodial Training Program. Housekeeping Methods and Materials. (Revised 1978).
ERIC Educational Resources Information Center
Oregon State Dept. of Education, Salem.
Designed as an instructional aid in teaching about custodian housekeeping methods and materials, this booklet contains information on the school custodian's responsibilities and methods for maintaining the building inside and outside, including the cleaning and sanitation of classrooms, restrooms, showerrooms, lunchrooms, corridors, and special…
ERIC Educational Resources Information Center
American School & University, 1998
1998-01-01
Explores the steps to take to reduce the likelihood that indoor-air-quality (IAQ) problems will develop in educational facilities. Highlights sources and hazards of IAQ when renovating buildings; control strategies and the establishment of IAQ close-out criteria for all renovation projects; heating, ventilation, and air-conditioning system…
Carpet in Schools: Myth and Reality.
ERIC Educational Resources Information Center
Chan, T. C.; Richardson, Michael D.; Jording, Cathy
2001-01-01
Carpet can serve as a type of finish over concrete, improves the acoustical environment, and helps build a more conducive, personalized learning environment. Problems associated with carpeting are related to raw materials, texture, cleaning materials, cost factors, moisture, and alleged contribution to poor indoor air quality. Recommendations are…
Development of a Methodology for the Derivation of Aquatic Plant Water Quality Criteria
Aquatic plants form the base of most aquatic food chains, comprise biodiversity-building habitats and are functionally important in carbon assimilation and oxygen evolution. The USEPA, as stated in the Clean Water Act, establishes criterion values for various pollutants found in ...
TESTING ANTIMICROBIAL PAINT EFFICACY ON GYPSUM WALLBOARD CONTAMINATED WITH STACHYBOTRYS CHARTARUM
Often mold contaminated building materials are not properly removed, some surface cleaning is performed and paint is applied in an attempt to alleviate the problem. The efficacy of antimicrobial paints to eliminate or control mold regrowth on surfaces can easily be tested on non-...
9 CFR 108.8 - Construction of buildings.
Code of Federal Regulations, 2014 CFR
2014-01-01
..., posts, doors, and all other parts of all structures, rooms, or facilities used for the preparation of... material, construction, and finish as may be readily and thoroughly cleaned. (b) All rooms used in.... (c) Rooms or compartments separate from the remainder of the establishment shall be provided at...
9 CFR 108.8 - Construction of buildings.
Code of Federal Regulations, 2013 CFR
2013-01-01
..., posts, doors, and all other parts of all structures, rooms, or facilities used for the preparation of... material, construction, and finish as may be readily and thoroughly cleaned. (b) All rooms used in.... (c) Rooms or compartments separate from the remainder of the establishment shall be provided at...
9 CFR 108.8 - Construction of buildings.
Code of Federal Regulations, 2011 CFR
2011-01-01
..., posts, doors, and all other parts of all structures, rooms, or facilities used for the preparation of... material, construction, and finish as may be readily and thoroughly cleaned. (b) All rooms used in.... (c) Rooms or compartments separate from the remainder of the establishment shall be provided at...
9 CFR 108.8 - Construction of buildings.
Code of Federal Regulations, 2012 CFR
2012-01-01
..., posts, doors, and all other parts of all structures, rooms, or facilities used for the preparation of... material, construction, and finish as may be readily and thoroughly cleaned. (b) All rooms used in.... (c) Rooms or compartments separate from the remainder of the establishment shall be provided at...
76 FR 59425 - Notice of Lodging of Consent Decree Under The Clean Air Act
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-26
... and collection systems, to correctly establish and monitor operating parameters, and to comply with... using model test protocols, adopt new monitoring practices, correct deficiencies in recordkeeping and... Environmental Protection Agency, Ariel Rios Building, 1200 Pennsylvania Avenue, NW., Washington, DC 20460...
Knowledge Transfer Project: Cultivating Smart Energy Solutions through Dynamic Peer-to-Peer Learning
DOE Office of Scientific and Technical Information (OSTI.GOV)
As energy policy makers and professionals convene in the Oresund region for the 9th Annual Clean Energy Ministerial (CEM9), the global community is as united as ever around the common goal of accelerating the transition to global clean energy. Through sustained collective effort and thought leadership, CEM partners and stakeholders are systematically addressing the barriers to the widescale deployment of clean energy technologies. Pivotal to their progress is the efficient sharing and dissemination of knowledge. To address that need, the CEM-initiative International SmartGrid Action Network (ISGAN) launched the Knowledge Transfer Project (KTP) in March 2016 to capture, collect, and sharemore » knowledge about smart grid technologies among countries and key stakeholders. Building on ISGAN's experience with delivering deep-dive workshops, the KTP fosters meaningful international dialogue on smart grids with a focus on developing competence and building capacity. After a successful 2016 pilot project and two consecutive projects, each with a different focus and structure, the KTP has become an established practice that can support existing ISGAN or CEM initiatives. To accommodate different purposes, needs, and practical circumstances, ISGAN has adopted three basic models for delivering KTP workshops: Country-Centric, Multilateral, and Hybrid. This fact sheet describes each approach through case studies of workshops in Mexico, India, and Belgium, and invites new ideas and partners for future KTPs.« less
Schreiber, Judith S; Hudnell, H Kenneth; Geller, Andrew M; House, Dennis E; Aldous, Kenneth M; Force, Michael S; Langguth, Karyn; Prohonic, Elizabeth J; Parker, Jean C
2002-01-01
Tetrachloroethylene (also called perchloroethylene, or perc), a volatile organic compound, has been the predominant solvent used by the dry-cleaning industry for many years. The U.S. Environmental Protection Agency (EPA) classified perc as a hazardous air pollutant because of its potential adverse impact on human health. Several occupational studies have indicated that chronic, airborne perc exposure adversely affects neurobehavioral functions in workers, particularly visual color discrimination and tasks dependent on rapid visual-information processing. A 1995 study by Altmann and colleagues extended these findings, indicating that environmental perc exposure at a mean level of 4,980 microg/m(3) (median=1,360 microg/m(3)) alters neurobehavioral functions in residents living near dry-cleaning facilities. Although the U.S. EPA has not yet set a reference concentration guideline level for environmental exposure to airborne perc, the New York State Department of Health set an air quality guideline of 100 microg/m(3). In the current residential study, we investigated the potential for perc exposure and neurologic effects, using a battery of visual-system function tests, among healthy members of six families living in two apartment buildings in New York City that contained dry-cleaning facilities on the ground floors. In addition, a day care investigation assessed the potential for perc exposure and effects among workers at a day care center located in the same one-story building as a dry-cleaning facility. Results from the residential study showed a mean exposure level of 778 microg/m(3) perc in indoor air for a mean of 5.8 years, and that perc levels in breath, blood, and urine were 1-2 orders of magnitude in excess of background values. Group-mean visual contrast sensitivity (VCS), a measure of the ability to detect visual patterns, was significantly reduced in the 17 exposed study participants relative to unexposed matched-control participants. The groups did not differ in visual acuity, suggesting that the VCS deficit was of neurologic origin. Healthy workers in the day care investigation were chronically exposed to airborne perc at a mean of 2,150 microg/m(3) for a mean of 4.0 years. Again, group-mean VCS, measured 6 weeks after exposure cessation, was significantly reduced in the nine exposed workers relative to matched controls, and the groups did not differ significantly in visual acuity. These results suggested that chronic, environmental exposure to airborne perc adversely affects neurobehavioral function in healthy individuals. Further research is needed to assess the susceptibility of the young and elderly to perc-induced effects, to determine whether persistent solvent-induced VCS deficits are a risk factor for the development of neurologic disease, and to identify the no observable adverse effect level for chronic, environmental, perc exposure in humans. PMID:12117642
Adhesion and removal kinetics of Bacillus cereus biofilms on Ni-PTFE modified stainless steel.
Huang, Kang; McLandsborough, Lynne A; Goddard, Julie M
2016-01-01
Biofilm control remains a challenge to food safety. A well-studied non-fouling coating involves codeposition of polytetrafluoroethylene (PTFE) during electroless plating. This coating has been reported to reduce foulant build-up during pasteurization, but opportunities remain in demonstrating its efficacy in inhibiting biofilm formation. Herein, the initial adhesion, biofilm formation, and removal kinetics of Bacillus cereus on Ni-PTFE-modified stainless steel (SS) are characterized. Coatings lowered the surface energy of SS and reduced biofilm formation by > 2 log CFU cm(-2). Characterization of the kinetics of biofilm removal during cleaning demonstrated improved cleanability on the Ni-PTFE coated steel. There was no evidence of biofilm after cleaning by either solution on the Ni-PTFE coated steel, whereas more than 3 log and 1 log CFU cm(-2) of bacteria remained on the native steel after cleaning with water and an alkaline cleaner, respectively. This work demonstrates the potential application of Ni-PTFE non-fouling coatings on SS to improve food safety by reducing biofilm formation and improving the cleaning efficiency of food processing equipment.
Clean Energy in City Codes: A Baseline Analysis of Municipal Codification across the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cook, Jeffrey J.; Aznar, Alexandra; Dane, Alexander
Municipal governments in the United States are well positioned to influence clean energy (energy efficiency and alternative energy) and transportation technology and strategy implementation within their jurisdictions through planning, programs, and codification. Municipal governments are leveraging planning processes and programs to shape their energy futures. There is limited understanding in the literature related to codification, the primary way that municipal governments enact enforceable policies. The authors fill the gap in the literature by documenting the status of municipal codification of clean energy and transportation across the United States. More directly, we leverage online databases of municipal codes to develop nationalmore » and state-specific representative samples of municipal governments by population size. Our analysis finds that municipal governments with the authority to set residential building energy codes within their jurisdictions frequently do so. In some cases, communities set codes higher than their respective state governments. Examination of codes across the nation indicates that municipal governments are employing their code as a policy mechanism to address clean energy and transportation.« less
REVIEW OF ALTERNATIVE ENHANCED CHEMICAL CLEANING OPTIONS FOR SRS WASTE TANKS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M.; Koopman, D.
2009-08-01
A literature review was conducted to support the Task Technical and Quality Assurance Plan for Alternative Enhanced Chemical Cleaning (AECC) for sludge heel removal funded as part of the EM-21 Engineering and Technology program. The goal was to identify potential technologies or enhancements to the baseline oxalic acid cleaning process for chemically dissolving or mobilizing Savannah River Site (SRS) sludge heels. The issues with the potentially large volume of oxalate solids generated from the baseline process have driven an effort to find an improved or enhanced chemical cleaning technology for the tank heels. This literature review builds on a previousmore » review conducted in 2003. A team was charged with evaluating the information in these reviews and developing recommendations of alternative technologies to pursue. The new information in this report supports the conclusion of the previous review that oxalic acid remains the chemical cleaning agent of choice for dissolving the metal oxides and hydroxides found in sludge heels in carbon steel tanks. The potential negative impact of large volumes of sodium oxalate on downstream processes indicates that the amount of oxalic acid used for chemical cleaning needs to be minimized as much as possible or the oxalic acid must be destroyed prior to pH adjustment in the receipt tank. The most straightforward way of minimizing the volume of oxalic acid needed for chemical cleaning is through more effective mechanical cleaning. Using a mineral acid to adjust the pH of the sludge prior to adding oxalic acid may also help to minimize the volume of oxalic acid used in chemical cleaning. If minimization of oxalic acid proves insufficient in reducing the volume of oxalate salts, several methods were found that could be used for oxalic acid destruction. For some waste tank heels, another acid or even caustic treatment (or pretreatment) might be more appropriate than the baseline oxalic acid cleaning process. Caustic treatment of high aluminum sludge heels may be appropriate as a means of reducing oxalic acid usage. Reagents other than oxalic acid may also be needed for removing actinide elements from the tank heels. A systems engineering evaluation (SEE) was performed on the various alternative chemical cleaning reagents and organic oxidation technologies discussed in the literature review. The objective of the evaluation was to develop a short list of chemical cleaning reagents and oxalic acid destruction methods that should be the focus of further research and development. The results of the SEE found that eight of the thirteen organic oxidation technologies scored relatively close together. Six of the chemical cleaning reagents were also recommended for further investigation. Based on the results of the SEE and plan set out in the TTQAP the following broad areas are recommended for future study as part of the AECC task: (1) Basic Chemistry of Sludge Dissolution in Oxalic Acid: A better understanding of the variables effecting dissolution of sludge species is needed to efficiently remove sludge heels while minimizing the use of oxalic acid or other chemical reagents. Tests should investigate the effects of pH, acid concentration, phase ratios, temperature, and kinetics of the dissolution reactions of sludge components with oxalic acid, mineral acids, and combinations of oxalic/mineral acids. Real waste sludge samples should be characterized to obtain additional data on the mineral phases present in sludge heels. (2) Simulant Development Program: Current sludge simulants developed by other programs for use in waste processing tests, while compositionally similar to real sludge waste, generally have more hydrated forms of the major metal phases and dissolve more easily in acids. Better simulants containing the mineral phases identified by real waste characterization should be developed to test chemical cleaning methods. (3) Oxalic Acid Oxidation Technologies: The two Mn based oxidation methods that scored highly in the SEE should be studied to evaluate long term potential. One of the AOP's (UV/O{sub 3}/Solids Separator) is currently being implemented by the SRS liquid waste organization for use in tank heel chemical cleaning. (4) Corrosion Issues: A program will be needed to address potential corrosion issues from the use of low molarity mineral acids and mixtures of oxalic/mineral acids in the waste tanks for short durations. The addition of corrosion inhibitors to the acids to reduce corrosion rates should be investigated.« less
Mapping the impact of climate change on surface recession of carbonate buildings in Europe.
Bonazza, Alessandra; Messina, Palmira; Sabbioni, Cristina; Grossi, Carlota M; Brimblecombe, Peter
2009-03-01
Climate change is currently attracting interest at both research and policy levels. However, it is usually explored in terms of its effect on agriculture, water, industry, energy, transport and health and as yet has been insufficiently addressed as a factor threatening cultural heritage. Among the climate parameters critical to heritage conservation and expected to change in the future, precipitation plays an important role in surface recession of stone. The Lipfert function has been taken under consideration to quantify the annual surface recession of carbonate stone, due to the effects of clean rain, acid rain and dry deposition of pollutants. The present paper provides Europe-wide maps showing quantitative predictions of surface recession on carbonate stones for the 21st century, combining a modified Lipfert function with output from the Hadley global climate model. Chemical dissolution of carbonate stones, via the karst effect, will increase with future CO(2) concentrations, and will come to dominate over sulfur deposition and acid rain effects on monuments and buildings in both urban and rural areas. During the present century the rainfall contribution to surface recession is likely to have a small effect, while the increase in atmospheric CO(2) concentration is shown to be the main factor in increasing weathering via the karst effect.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guevara, K.C.; Fellinger, A.P.; Aylward, R.S.
The Department of Energy's Savannah River Site has a 60-year history of successfully operating nuclear facilities and cleaning up the nuclear legacy of the Cold War era through the processing of radioactive and otherwise hazardous wastes, remediation of contaminated soil and groundwater, management of nuclear materials, and deactivation and decommissioning of excess facilities. SRS recently unveiled its Enterprise.SRS (E.SRS) strategic vision to identify and facilitate application of the historical competencies of the site to current and future national and global challenges. E.SRS initiatives such as the initiative to Develop and Demonstrate Next generation Clean-up Technologies seek timely and mutually beneficialmore » engagements with entities around the country and the world. One such ongoing engagement is with government and industry in Japan in the recovery from the devastation of the Fukushima Daiichi Nuclear Power Station. (authors)« less
Photocatalytic self-cleaning TiO2 coatings on carbonatic stones
NASA Astrophysics Data System (ADS)
Bergamonti, Laura; Bondioli, Federica; Alfieri, Ilaria; Lorenzi, Andrea; Mattarozzi, Monica; Predieri, Giovanni; Lottici, Pier Paolo
2016-02-01
A self-cleaning coating based on TiO2 nanoparticles obtained by sol-gel method in an alkaline environment has been tested on different types of carbonatic stones: Botticino, Carrara and Pietra Dorata, frequently used in historic buildings. XRD and Raman measurements confirmed the nanocrystalline nature of titania in anatase form, with 5-10 nm crystal size, and evidenced a small amount of brookite. A fast photocatalytic oxidation by TiO2 coatings of the stained stones with methyl orange and methylene blue under UV lamp irradiation has been assessed. The enhancement of surface wettability due to UV-induced TiO2 hydrophilicity has been evidenced by contact angle measurements. ESEM/EDS showed a surface distribution of the coating fairly homogeneous. The coating does not introduce significant colorimetric changes of the stones and does not alter the water capillarity absorption. Thus, the alkaline nanocrystalline TiO2 is promising for self-cleaning coatings on carbonatic stones.
Physico-Chemical Dynamics of Nanoparticle Formation during Laser Decontamination
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, M.D.
2005-06-01
Laser-ablation based decontamination is a new and effective approach for simultaneous removal and characterization of contaminants from surfaces (e.g., building interior and exterior walls, ground floors, etc.). The scientific objectives of this research are to: (1) characterize particulate matter generated during the laser-ablation based decontamination, (2) develop a technique for simultaneous cleaning and spectroscopic verification, and (3) develop an empirical model for predicting particle generation for the size range from 10 nm to tens of micrometers. This research project provides fundamental data obtained through a systematic study on the particle generation mechanism, and also provides a working model for predictionmore » of particle generation such that an effective operational strategy can be devised to facilitate worker protection.« less
Human perspectives in horticulture
Charles A. Lewis
1977-01-01
Gardening produces not only vegetables and flowers, but also social and behavioral benefits. In low-income housing sites in New York, Philadelphia, and Chicago, gardening programs have resulted in reduced vandalism, new neighborliness, cleaned and painted buildings and streets, and other improvements. The human response to plants, and the qualities of plants that...
BUILDING AN ENVIRONMENTAL TRAINING MODEL, MAPCORE - A TRAINING EXERCISE FOR AIR POLLUTION CONTROL.
ERIC Educational Resources Information Center
SIEGEL, GILBERT B.; SULLIVAN, DONALD M.
NEW AIR POLLUTION CONTROL PROGRAMS HAVE RESULTED FROM THE "CLEAN AIR ACT" PASSED BY CONGRESS IN DECEMBER 1963. THE UNIVERSITY OF SOUTHERN CALIFORNIA DEVELOPED A TRAINING MODEL, CALLED "MAPCORE," WHICH PROVIDES A SEMISTRUCTURED ENVIRONMENT, IS PRACTICAL AND REALISTIC IN APPROACH, PROVIDES OPPORTUNITY FOR HIGH CREATIVITY,…
215. Photocopy of photograph, U.S. Army, ca. 1970 (original print ...
215. Photocopy of photograph, U.S. Army, ca. 1970 (original print located at Rocky Mountain Arsenal, Commerce City, Colorado). CLEANING TON CONTAINERS IN BUILDING 1606. - Rocky Mountain Arsenal, Bounded by Ninety-sixth Avenue & Fifty-sixth Avenue, Buckley Road, Quebec Street & Colorado Highway 2, Commerce City, Adams County, CO
40 CFR 63.11180 - What definitions do I need to know?
Code of Federal Regulations, 2012 CFR
2012-07-01
... installation, to pavements, or to curbs. Cleaning material means a solvent used to remove contaminants and... portable buildings at the site of installation, to pavements, or to curbs. Facility maintenance also... designed and operated between 0.1 and 10 pounds per square inch gauge (psig) air atomizing pressure...
40 CFR 63.11180 - What definitions do I need to know?
Code of Federal Regulations, 2014 CFR
2014-07-01
... installation, to pavements, or to curbs. Cleaning material means a solvent used to remove contaminants and... portable buildings at the site of installation, to pavements, or to curbs. Facility maintenance also... designed and operated between 0.1 and 10 pounds per square inch gauge (psig) air atomizing pressure...
40 CFR 63.11180 - What definitions do I need to know?
Code of Federal Regulations, 2011 CFR
2011-07-01
... installation, to pavements, or to curbs. Cleaning material means a solvent used to remove contaminants and... portable buildings at the site of installation, to pavements, or to curbs. Facility maintenance also... designed and operated between 0.1 and 10 pounds per square inch gauge (psig) air atomizing pressure...
40 CFR 63.11180 - What definitions do I need to know?
Code of Federal Regulations, 2010 CFR
2010-07-01
... installation, to pavements, or to curbs. Cleaning material means a solvent used to remove contaminants and... portable buildings at the site of installation, to pavements, or to curbs. Facility maintenance also... designed and operated between 0.1 and 10 pounds per square inch gauge (psig) air atomizing pressure...
40 CFR 63.11180 - What definitions do I need to know?
Code of Federal Regulations, 2013 CFR
2013-07-01
... installation, to pavements, or to curbs. Cleaning material means a solvent used to remove contaminants and... portable buildings at the site of installation, to pavements, or to curbs. Facility maintenance also... designed and operated between 0.1 and 10 pounds per square inch gauge (psig) air atomizing pressure...
News Room | Argonne National Laboratory
-friction dry lubricant that has hundreds of industrial applications and can be used virtually wherever two pieces of metal rub together in dry conditions. Left to right: Mathew Cherukara, Ali Erdemir, Badri dry lubricant Materials Today We need real scientific breakthroughs to build a clean energy economy
Ohio Schools and Privatization: Opportunity or Risk?
ERIC Educational Resources Information Center
Hughes, William
Food service, transportation and building cleaning and maintenance are big business and are seen as candidates for privatization. In Ohio, a 30-item questionnaire was developed for the state's school district superintendents. Results were generated from the 143 questionnaires that were returned (70 percent response rate). Findings show that Ohio's…
FIELD MEASUREMENT OF VAPOR INTRUSION RATES AT A PCE SITE (ABSTRACT ONLY)
A field study was performed to evaluate vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 years old and once housed a dry cleaning operation. Results from an initial site ch...
Responding to the Calls for Reform.
ERIC Educational Resources Information Center
Bok, Derek
1988-01-01
Four challenges facing America are identified: to build a stronger economy with greater competiveness, productivity, and growth; to foster equal opportunity and full integration of poor and minority groups; to improve the quality of life by reducing poverty, cleaning up the environment; and to strengthen values and moral standards. (MLW)
47. CAPE COD AIR STATION PAVE PAWS FACILITY AERIAL VIEW ...
47. CAPE COD AIR STATION PAVE PAWS FACILITY AERIAL VIEW OF "A" FACE (LEFT) WITH CLEANING SYSTEM INSTALLED (NOW REMOVED) AND "B" FACE (RIGHT) WITH CONSTRUCTION CRANE IN USE. - Cape Cod Air Station, Technical Facility-Scanner Building & Power Plant, Massachusetts Military Reservation, Sandwich, Barnstable County, MA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ottney, T.C.
Filtration systems that are incorrectly selected, installed and maintained can cause excessive particulates in occupied spaces. This article describes how to identify and correct problems. Particulate matter can be removed from ventilation air at several sites within a building. These sites include: on heat exchanger surfaces; inside ductwork, ceiling tiles and diffusers; and in the air filter. The cost associated with removing these unwanted contaminants is unavoidable. However, this removal cost varies depending on where the particulates have been deposited. Not all particulates that are generated by work-related activities are transported to the filter bank by return air currents beforemore » being deposited on other surfaces. Accordingly, walls still have to be repainted at varying intervals and carpeting vacuumed. Ceiling tiles will discolor at a rate that is influenced by their texture, the air outlet velocity, the amount of dirt in the ventilation air and how much contaminant is being generated in the room. It is estimated that 15% of ventilation air escapes the air filtration process. This leakage results in higher utility, janitorial and redecorating costs as well as contributing to employee absenteeism. When building management does not prevent it, air-conditioning coils and ductwork become an unintended part of the building's air filtration system. In time, this is much more expensive both in energy and cleaning costs than the steps available to keep them clean. Good particulate control can lower the total cost of building operation. However, a building operator may not have to upgrade to a higher efficiency filter to achieve higher system efficiency. Simply eliminating the source of leaks and better management of the existing filters may be all that is necessary.« less
Design and Analysis of Photovoltaic (PV) Power Plant at Different Locations in Malaysia
NASA Astrophysics Data System (ADS)
Islam, M. A.; Hasanuzzaman, M.; Rahim, N. A.
2018-05-01
Power generation from sun oriented vitality through a photovoltaic (PV) system is ended up prevalent over the world due to clean innovation. Geographical location of Malaysia is very favorable for PV power generation system. The Malaysian government has also taken different steps to increase the use of solar energy especially by emphasizing on building integrated PV (BIPV) system. Comparative study on the feasibility of BIPV installation at the different location of Malaysia is rarely found. On the other hand, solar cell temperature has a negative impact on the electricity generation. So in this study cost effectiveness and initial investment cost of building integrated grid connected solar PV power plant in different regions of Malaysia have been carried. The effect of PV solar cell temperature on the payback period (PBP) is also investigated. Highest PBP is 12.38 years at Selangor and lowest PBP is 9.70 years at Sabah (Kota Kinabalu). Solar cell temperature significantly increases the PBP of PV plant and highest 14.64% and lowest 13.20% raise of PBP are encountered at Penang and Sarawak respectively.
Water Quality Standards for Coral Reef Protection | Science ...
The U.S. Clean Water Act provides a legal framework to protect coastal biological resources such as coral reefs, mangrove forests, and seagrass meadows from the damaging effects of human activities. Even though many resources are protected under this authority, water quality standards have not been effectively applied to coral reefs. The Environmental Protection Agency is promoting biocriteria and other water quality standards through collaborative development of bioassessment procedures, indicators and monitoring strategies. To support regulatory action, bioassessment indicators must be biologically meaningful, relevant to management, responsive to human disturbance, and relatively immune to natural variability. A rapid bioassessment protocol for reef-building stony corals was developed and tested for regulatory applicability. Preliminary testing in the Florida Keys found indicators had sufficient precision and provided information relevant to coral reef management. Sensitivity to human disturbance was demonstrated in the U.S. Virgin Islands for five of eight indicators tested. Once established, monitoring programs using these indicators can provide valuable, long-term records of coral condition and regulatory compliance. Development of a rapid bioassement protocol for reef-building stony corals was tested for regulatory applicability.
McCall, Michael K.; Bressers, Hans Th. A.
2007-01-01
There is a growing assumption that payments for environmental services including carbon sequestration and greenhouse gas emission reduction provide an opportunity for poverty reduction and the enhancement of sustainable development within integrated natural resource management approaches. Yet in experiential terms, community-based natural resource management implementation falls short of expectations in many cases. In this paper, we investigate the asymmetry between community capacity and the Land Use Land Use Change Forestry (LULUCF) provisions of the Clean Development Mechanism within community forests in Cameroon. We use relevant aspects of the Clean Development Mechanism criteria and notions of “community capacity” to elucidate determinants of community capacity needed for CDM implementation within community forests. The main requirements are for community capacity to handle issues of additionality, acceptability, externalities, certification, and community organisation. These community capacity requirements are further used to interpret empirically derived insights on two community forestry cases in Cameroon. While local variations were observed for capacity requirements in each case, community capacity was generally found to be insufficient for meaningful uptake and implementation of Clean Development Mechanism projects. Implications for understanding factors that could inhibit or enhance community capacity for project development are discussed. We also include recommendations for the wider Clean Development Mechanism/Kyoto capacity building framework. PMID:17377732
Pegasus ICON Spacecraft Move Into Cleanroom
2018-05-01
NASA's Ionospheric Connection Explorer (ICON) is moved to a clean room on May 4, 2018, inside Building 1555 at Vandenberg Air Force Base in California. The explorer will launch on June 15, 2018, from Kwajalein Atoll in the Marshall Islands (June 14 in the continental United States) on Orbital ATK's Pegasus XL rocket, which is attached to the company's L-1011 Stargazer aircraft. ICON will study the frontier of space - the dynamic zone high in Earth's atmosphere where terrestrial weather from below meets space weather above. The explorer will help determine the physics of Earth's space environment and pave the way for mitigating its effects on our technology, communications systems and society.
Establishing and monitoring an aseptic workspace for building the MOMA mass spectrometer
NASA Astrophysics Data System (ADS)
Lalime, Erin N.; Berlin, David
2016-09-01
Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the European Space Agency (ESA) ExoMars 2020 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). MOMA-MS is a life-detection instrument and thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 spore/m2 are allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three clean rooms with varying levels of bioburden control. The Aseptic Assembly Clean room has the highest level of control, applying three different bioburden reducing methods: 70% Isopropyl Alcohol (IPA), 7.5% Hydrogen Peroxide, and Ultra-Violet C (UVC) light. The three methods are used in rotation and each kills microorganisms by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Clean rooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of clean rooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and Dry Heat microbial Reduction (DHMR) verification. The clean rooms are monitored for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic and other clean room.
Establishing and Monitoring an Aseptic Workspace for Building the MOMA Mass Spectrometer
NASA Technical Reports Server (NTRS)
Lalime, Erin N.; Berlin, David
2016-01-01
Mars Organic Molecule Analyzer (MOMA) is an instrument suite on the European Space Agency (ESA) ExoMars 2020 Rover, and the Mass Spectrometer (MOMA-MS) is being built at Goddard Space Flight Center (GSFC). MOMA-MS is a life-detection instrument and thus falls in the most stringent category of Planetary Protection (PP) biological cleanliness requirements. Less than 0.03 spore/m2 are allowed in the instrument sample path. In order to meet these PP requirements, MOMA-MS must be built and maintained in a low bioburden environment. The MOMA-MS project at GSFC maintains three clean rooms with varying levels of bioburden control. The Aseptic Assembly Clean room has the highest level of control, applying three different bioburden reducing methods: 70% Isopropyl Alcohol (IPA), 7.5% Hydrogen Peroxide, and Ultra-Violet C (UVC) light. The three methods are used in rotation and each kills microorganisms by a different mechanism, reducing the likelihood of microorganisms developing resistance to all three. The Integration and Mars Chamber Clean rooms use less biocidal cleaning, with the option to deploy extra techniques as necessary. To support the monitoring of clean rooms and verification that MOMA-MS hardware meets PP requirements, a new Planetary Protection lab was established that currently has the capabilities of standard growth assays for spore or vegetative bacteria, rapid bioburden analysis that detects Adenosine Triphosphate (ATP), plus autoclave and Dry Heat microbial Reduction (DHMR) verification. The clean rooms are monitored for vegetative microorganisms and by rapid ATP assay, and a clear difference in bioburden is observed between the aseptic and other clean room.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kurnik, Charles W.; Romberger, Jeff
The HVAC Controls Evaluation Protocol is designed to address evaluation issues for direct digital controls/energy management systems/building automation systems (DDC/EMS/BAS) that are installed to control heating, ventilation, and air-conditioning (HVAC) equipment in commercial and institutional buildings. (This chapter refers to the DDC/EMS/BAS measure as HVAC controls.) This protocol may also be applicable to industrial facilities such as clean rooms and labs, which have either significant HVAC equipment or spaces requiring special environmental conditions.
Energy Savings Potential and RD&D Opportunities for Commercial Building Appliances (2015 Update)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Goetzler, William; Guernsey, Matt; Foley, Kevin
The Department of Energy commissioned a technology characterization and assessment of appliances used in commercial buildings for cooking, cleaning, water heating, and other end-uses. The primary objectives of this study were to document the energy consumed by commercial appliances and identify research, development, and demonstration opportunities to improve energy efficiency in each end-use. This report serves as an update to a 2009 report of the same name by incorporating updated data and sources where possible and updating the available technology options that provide opportunities for efficiency improvements.
Lei, Hao; Jones, Rachael M; Li, Yuguo
2017-01-18
Cleaning of environmental surfaces in hospitals is important for the control of methicillin-resistant Staphylococcus aureus (MRSA) and other hospital-acquired infections transmitted by the contact route. Guidance regarding the best approaches for cleaning, however, is limited. In this study, a mathematical model based on ordinary differential equations was constructed to study MRSA concentration dynamics on high-touch and low-touch surfaces, and on the hands and noses of two patients (in two hospitals rooms) and a health care worker in a hypothetical hospital environment. Two cleaning interventions - whole room cleaning and wipe cleaning of touched surfaces - were considered. The performance of the cleaning interventions was indicated by a reduction in MRSA on the nose of a susceptible patient, relative to no intervention. Whole room cleaning just before first patient care activities of the day was more effective than whole room cleaning at other times, but even with 100% efficiency, whole room cleaning only reduced the number of MRSA transmitted to the susceptible patient by 54%. Frequent wipe cleaning of touched surfaces was shown to be more effective that whole room cleaning because surfaces are rapidly re-contaminated with MRSA after cleaning. Wipe cleaning high-touch surfaces was more effective than wipe cleaning low-touch surfaces for the same frequency of cleaning. For low wipe cleaning frequency (≤3 times per hour), high-touch surfaces should be targeted, but for high wipe cleaning frequency (>3 times per hour), cleaning should target high- and low-touch surfaces in proportion to the surface touch frequency. This study reproduces the observations from a field study of room cleaning, which provides support for the validity of our findings. Daily whole room cleaning, even with 100% cleaning efficiency, provides limited reduction in the number of MRSA transmitted to susceptible patients via the contact route; and should be supplemented with frequent targeted cleaning of high-touch surfaces, such as by a wipe or cloth containing disinfectant.
Bore pile foundation tall buildings closed in the heritage building
NASA Astrophysics Data System (ADS)
Triastuti, Nusa Setiani
2017-11-01
Bore pile foundation for high building surroundings heritage building should be not damage. Construction proses must good, no necking, no mixed deep water, no sliding soil, nonporous concrete. Objective the execution of bore pile so that heritage buildings and neighboring buildings that are old do not experience cracks, damage and tilting. The survey methodology was observe the process of the implementation of the dominant silt, clay soil, in addition a limited space and to analyze the results of loading tests, investigations of soil and daily reports. Construction process determines the success of the structure bore pile in high building structure bearing, without damaging a heritage building. Attainment the hard soil depth, density concrete, observable clean reinforcement in the implementation. Monitoring the implementation of, among others, the face of the ground water little reduce in the area and outside the footprint of the building, no impact of vibration drilling equipment, watching the mud content on the water coming out at the time of drilling, concrete volume was monitored each 2 m bore depth of pile, The result researched heritage building was not damage. The test results bore pile axial, lateral analyzed the results have the appropriate force design required.
Indoor-Outdoor Air Leakage of Apartments and Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, P.N.; Shehabi, A.; Chan, R.W.
We compiled and analyzed available data concerning indoor-outdoor air leakage rates and building leakiness parameters for commercial buildings and apartments. We analyzed the data, and reviewed the related literature, to determine the current state of knowledge of the statistical distribution of air exchange rates and related parameters for California buildings, and to identify significant gaps in the current knowledge and data. Very few data were found from California buildings, so we compiled data from other states and some other countries. Even when data from other developed countries were included, data were sparse and few conclusive statements were possible. Little systematicmore » variation in building leakage with construction type, building activity type, height, size, or location within the u.s. was observed. Commercial buildings and apartments seem to be about twice as leaky as single-family houses, per unit of building envelope area. Although further work collecting and analyzing leakage data might be useful, we suggest that a more important issue may be the transport of pollutants between units in apartments and mixed-use buildings, an under-studied phenomenon that may expose occupants to high levels of pollutants such as tobacco smoke or dry cleaning fumes.« less
Evaluation of two cleaning methods for the removal of asbestos fibers from carpet
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kominsky, J.R.; Freyberg, R.W.; Chesson, J.
The research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. Routine carpet cleaning operations using high-efficiency particulate air (HEPA) filtered dry vacuum cleaners and HEPA-filtered hot-water extraction cleaners were simulated on carpet artificially contaminated with asbestos fibers. Overall, wet cleaning the carpet with a hot-water extraction cleaner reduced the level of asbestos contamination by approximately 70 percent. There was no significant evidence of either an increase or a decrease in the asbestos concentration after dry vacuuming. The level ofmore » asbestos contamination had no significant effect on the difference between the carpet asbestos concentrations before and after cleaning. Airborne asbestos concentrations were between two and four times greater during the carpet cleaning activities. The level of asbestos contamination in the carpet cleaning activities. The level of asbestos contamination in the carpet and the type of cleaning method used had no statistically significant effect on the difference between the airborne asbestos concentrations before and during cleaning.« less
Storage and utilization patterns of cleaning products in the home: toxicity implications.
Sawalha, Ansam F
2007-11-01
Cleaning products are used to achieve cleaner homes. However, they have been responsible for a considerable number of poisoning cases. The aims of this study were to investigate the storage and utilization patterns of cleaning products in the home, as well as the risk of adverse and toxic effects produced by them. This study has been performed using a questionnaire that was developed by the Poison Control and Drug Information Center (PCDIC). The questionnaire was distributed randomly in northern Palestine. The questionnaire included questions regarding storage, utilization habits, and the adverse effects experienced by respondents upon handling the cleaning products. All respondents utilized and stored cleaning products in their homes. Chlorine bleach and acidic cleaning products were the most common. Respondents stored cleaning products at different places in their homes, but most of those storage places were suboptimal and were within the reach of children. The daily utilization rate of cleaning products was 1.6+/-0.8 with chlorine bleach being the most commonly used. Of the respondents, 27% reported experiencing a wide range of acute adverse and toxic effects resulting from cleaning product use and that exposure occurred mainly via inhalation. Caustic substances, bleach, and kerosene were the agents mainly involved in producing these adverse and toxic effects. About half of those who experienced adverse and toxic effects sought medical help, and 22% of them were children younger than 6 years of age. Finally, most respondents reported mixing and discarding cleaning product leftovers and their containers improperly. Correct utilization and safer storage of cleaning products is encouraged. Several preventive strategies should be implemented in order to decrease the incidence of accidental harmful exposure that is due to cleaning agents. The role of the PCDIC is very important in the education, prevention, and management of cleaning product-induced adverse effects.
Comparative Mirror Cleaning Study: 'A Study on Removing Particulate Contamination'
NASA Technical Reports Server (NTRS)
Houston, Karrie
2007-01-01
The cleanliness of optical surfaces is recognized as an industry-wide concern for the performance of optical devices such as mirrors and telescopes, microscopes and lenses, lasers and interferometers, and prisms and optical filters. However, no standard has been established for optical cleaning and there is no standard definition of a 'clean' optical element. This study evaluates the effectiveness of commonly used optical cleaning techniques based on wafer configuration, contamination levels, and the number and size of removed particles. It is concluded that cleaning method and exposure time play a significant factor in obtaining a high removal percentage. The detergent bath and solvent rinse method displayed an increase in effective removal percentage as the contamination exposure increased. Likewise, CO2 snow cleaning showed a relatively consistent cleaning effectiveness. The results can help ensure mission success to flight projects developed for the NASA Origins Program. Advantages and disadvantages of each of the optical cleaning methods are described.
Cavitation effects in ultrasonic cleaning baths
NASA Technical Reports Server (NTRS)
Glasscock, Barbara H.
1995-01-01
In this project, the effect of cavitation from aqueous ultrasonic cleaning on the surfaces of metal and non-metal sample coupons was studied. After twenty cleaning cycles, the mass loss from the aluminum coupons averaged 0.22 mg/sq cm surface area and 0.014 mg/sq cm for both stainless steel and titanium. The aluminum coupons showed visual evidence of minor cavitation erosion in regions of previously existing surface irregularities. The non-metal samples showed some periods of mass gain. These effects are believed to have minor impact on hardware being cleaned, but should be evaluated in the context of specific hardware requirements. Also the ultrasonic activity in the large cleaning baths was found to be unevenly distributed as measured by damage to sheets of aluminum foil. It is therefore recommended that items being cleaned in an ultrasonic bath be moved or conveyed during the cleaning to more evenly distribute the cavitation action provide more uniform cleaning.
Deshpande, Abhishek; Donskey, Curtis J
2017-09-01
Cleaning and disinfection in healthcare facilities is essential to ensure patient safety. This review examines practical strategies used to assess and improve the effectiveness of daily and post-discharge manual cleaning in healthcare facilities. Effective implementation of cleaning interventions requires objective monitoring of staff performance with regular feedback on performance. Use of fluorescent markers to assess thoroughness of cleaning and measurement of residual ATP can provide rapid and objective feedback to personnel and have been associated with improved cleaning. Direct observation of cleaning and interviews with front-line staff are useful to identify variations and deficiencies in practice that may not be detected by other methods. Although not recommended for routine monitoring, cultures can be helpful for outbreak investigations. Monitoring and feedback can be effective in improving cleaning and disinfection in healthcare facilities. Ongoing commitment within institutions is needed to sustain successful cleaning and disinfection programs.
VIEW LOOKING NORTHEAST, LOCK 35 IS ON THE RIGHT. CANAL ...
VIEW LOOKING NORTHEAST, LOCK 35 IS ON THE RIGHT. CANAL WORKERS ARE CLEANING TRASH GRATES TO LOCK 35 WATER INLET. ENTRANCE TO OLD LOCK 71 ON LEFT. NOTE THE SEDIMENT BUILD UP IN THE ENTRANCE CHANNEL TO OLD LOCK 71. - New York State Barge Canal, Lockport Locks, Richmond Avenue, Lockport, Niagara County, NY
18. DETAIL OF COMBINATION HANDWASH SINK/KNIFE STERILIZER ON SPLITTERS' PLATFORM; ...
18. DETAIL OF COMBINATION HANDWASH SINK/KNIFE STERILIZER ON SPLITTERS' PLATFORM; KNIVES AND CLEAVERS WERE CLEANED FREQUENTLY BY DIPPING THEM INTO STEAM-HEATED WATER IN THE RECTANGULAR TANK; NOTE FOOT-OPERATED FAUCETS - Rath Packing Company, Beef Killing Building, Sycamore Street between Elm & Eighteenth Streets, Waterloo, Black Hawk County, IA
Building the Clean Energy Future of States and Local Communities | NREL
Partnership Successes Photo of a hand holding an ecobee smart thermostat Bringing Comfort, Convenience, and adoption-a win-win for both homeowners and utilities. Learn more. Blue electric bus in California's Santa Clara Valley Evaluating Electric Bus Grid Integration Performance in California's Santa Clara Valley
Electric power is one of the basic needs for the development of any community. With electric power lacking in most rural communities in Africa, providing basic amenities that are dependent on power such as clean portable drinking water, powering equipment in health and dent...
ERIC Educational Resources Information Center
Wessels, Michael G.
Planetary life support systems are at risk, and clean air, unpolluted water, and arable land are increasingly scarce. Environmental problems such as ozone depletion and the threat of global warming transcend national boundaries and confront our species with fundamental questions about survival, quality of life, and responsibility to future…
The Design of Exhaust Systems and Discharge Stacks [With Comments].
ERIC Educational Resources Information Center
Clarke, John H.
1963-01-01
An important part of ventilating for safety consists of providing the necessary exhaust systems to remove building contaminants safely. Further, the effluent must be cleaned within practical limits by means of filters, collectors, and scrubbers. Where recirculation is not safe or feasible, the effluent must be discharged to the outside in a manner…
A site visit to the CEG confirmed that water and sanitation are priorities of the school board and parents of the children at the school. Both the need and desire for clean water and improved sanitation was apparent. The skills and materials needed to build...
Linda A. Joyce; Steven W. Running; David D. Breshears; Virginia H. Dale; Robert W. Malmsheimer; R. Neil Sampson; Brent Sohngen; Christopher W. Woodall
2014-01-01
Forests occur within urban areas, at the interface between urban and rural areas (wildland-urban interface), and in rural areas. Urban forests contribute to clean air, cooling buildings, aesthetics, and recreation in parks. Development in the wildland-urban interface is increasing because of the appeal of owning homes near or in the woods. In rural areas, market...
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2010-04-01
Expanding training opportunities in the weatherization of buildings will accelerate learning and provide a direct path for many Americans to find jobs in the clean energy field. The National Weatherization Training Portal (NWTP), which is now in the final stages of testing, features multi-media, interactive, self-paced training modules.
CTEPP DATA COLLECTION FORM 05: CHILD DAY CARE CENTER PRE-MONITORING QUESTIONNAIRE
This data collection form is used to identify the potential sources of pollutants at the day care center. The day care teacher is asked questions related to the age of their day care building; age and frequency of cleaning carpets or rugs; types of heating and air conditioning de...
FY 2009 National Renewable Energy Laboratory (NREL) Annual Report: A Year of Energy Transformation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
2010-01-01
This FY2009 Annual Report surveys the National Renewable Energy Laboratory's (NREL) accomplishments in renewable energy and energy efficiency research and development, commercialization and deployment of technologies, and strategic energy analysis. It offers NREL's vision and progress in building a clean, sustainable research campus and reports on community involvement.
Cleaning up Water? Or Building Rural Community? Community Watershed Organizations in Pennsylvania
ERIC Educational Resources Information Center
Stedman, Richard; Lee, Brian; Brasier, Kathryn; Weigle, Jason L.; Higdon, Francis
2009-01-01
Recent initiatives from state and federal government agencies have helped foster the formation of community-based watershed organizations. Although there is a great deal of enthusiasm about the potential of these organizations to enhance water quality, relatively little attention has been paid to the impacts these organizations may have on the…
10. VIEW OF LAMINARFLOW FILTER WALL NEAR SOUTH WALL OF ...
10. VIEW OF LAMINAR-FLOW FILTER WALL NEAR SOUTH WALL OF CLEAN ROOM (102). NOTE GROUNDING CABLES NEAR BASEBOARD IN LOWER RIGHT BACKGROUND. WHITE SQUARE IN FOREGROUND IS A FLOOR DRAIN COVERED WITH TAPE. - Vandenberg Air Force Base, Space Launch Complex 3, Vehicle Support Building, Napa & Alden Roads, Lompoc, Santa Barbara County, CA
Bridges to sustainable tropical health
Singer, Burton H.; de Castro, Marcia Caldas
2007-01-01
Ensuring sustainable health in the tropics will require bridge building between communities that currently have a limited track record of interaction. It will also require new organizational innovation if much of the negative health consequences of large-scale economic development projects are to be equitably mitigated, if not prevented. We focus attention on three specific contexts: (i) forging linkages between the engineering and health communities to implement clean water and sanitation on a broad scale to prevent reworming, after the current deworming-only programs, of people by diverse intestinal parasites; (ii) building integrated human and animal disease surveillance infrastructure and technical capacity in tropical countries on the reporting and scientific evidence requirements of the sanitary and phytosanitary agreement under the World Trade Organization; and (iii) developing an independent and equitable organizational structure for health impact assessments as well as monitoring and mitigation of health consequences of economic development projects. Effective global disease surveillance and timely early warning of new outbreaks will require a far closer integration of veterinary and human medicine than heretofore. Many of the necessary surveillance components exist within separate animal- and human-oriented organizations. The challenge is to build the necessary bridges between them. PMID:17913894
Surface cleaning for negative electron affinity GaN photocathode
NASA Astrophysics Data System (ADS)
Qiao, Jianliang; Yin, Yingpeng; Gao, Youtang; Niu, Jun; Qian, Yunsheng; Chang, Benkang
2012-10-01
In the preparation process for negative electron affinity (NEA) GaN photocathode, the surface cleanness is very important to activation, it influences the sensitivity and stability of NEA GaN photocathode. The traditional corrosion methods based on oxidizing and dissolving can't remove oxygen (O) and carbon (C) on GaN surface effectively. How to get an ideal atom clean surface is still an important question at present. The cleaning techniques for GaN photocathode was studied by using NEA photocathode activation system and XPS surface analysis system. The experiment sample is p-type GaN doped with Mg, doped concentration is 1.37×1017 cm-3, the transfer rate is 3.08 cm2/V-S, and the thickness of activation layer is 0.51 μm, the substrate is 300 μm thick sapphire. The sample was dealed with chemical cleaning depuration at first. And to get the atom clean surface, the vacuum heat cleaning process was needed. The methods of chemical cleaning and the vacuum heating cleaning were given in detail. According to the X-ray photoelectron spectroscopy of GaN surface after chemical cleaning and the vacuum degree curve of the activation chamber during the heat cleaning, the cleaning effect and the cleaning mechanism were discussed. After the effective chemical cleaning and the heating of 700 Centigrade degree about 20 minutes in ultrahigh vacuum system, the oxides and carbon contaminants on cathode surface can be removed effectively, and the ideal atom clean surface can be obtained. The purpose of heating depuration process is that not only to get the atom clean GaN surface, but also to guarantee the contents of Ga, N on GaN surface stabilize and to keep the system ultra-high vacuum degree. Because of the volatilization of oxide and carbon impurity on the cathode surface, the vacuum degree curve drops with the rising of temperature on the whole.
Removal of odor using biofilter from duck confinement buildings.
Lau, Anthony; Cheng, Kimberly
2007-06-01
The poultry and waterfowl industry in the Fraser Valley of British Columbia needs to deal with odor emission problems. The objective of this study is to evaluate the performance of a pilot-scale biofiltration system for treating odors from the exhaust air streams of a commercial duck farm building before their release to the atmosphere. A pilot-scale biofiltration system with semi-enclosed wooden structure was designed, constructed and installed to treat the exhaust air from one of the 12 operating ventilation exhaust fans, having a ventilation rate of 2.36 m3/s. The empty bed residence time of the biofilter was 5-10 seconds at the design flow rate. The biofilter media comprised of 2 parts softwood chips and barks to 1 part finished compost. Fabric filters were used for pre-treatment to protect the biofilter from clogging by dust particles and feathers. Odor reduction was determined by measuring the concentration of the air entering and leaving the biofilter via olfactometry analysis. The odor concentration of untreated barn air was found to vary from 8553+/-1006 to 12171+/-1575 OU/m3; however, the odor concentration was substantially reduced to 420+/-195 OU/m(3) after the manure storage was cleaned out at the end of summer. The odor removal efficiency of the biofilter system averaged 95+/-3%. The high frequency of cleaning and replacement required of the fabric filters would considerably increase the operating cost. Alternative methods of dust and odor removal that are more cost-effective will need to be investigated in the future.
Hon, Chun-Yip; Chua, Prescillia Ps; Danyluk, Quinn; Astrakianakis, George
2014-06-01
Occupational exposure to antineoplastic drugs has been documented to result in various adverse health effects. Despite the implementation of control measures to minimize exposure, detectable levels of drug residual are still found on hospital work surfaces. Cleaning these surfaces is considered as one means to minimize the exposure potential. However, there are no consistent guiding principles related to cleaning of contaminated surfaces resulting in hospitals to adopt varying practices. As such, this pilot study sought to evaluate current cleaning protocols and identify those factors that were most effective in reducing contamination on drug preparation surfaces. Three cleaning variables were examined: (1) type of cleaning agent (CaviCide®, Phenokil II™, bleach and chlorhexidine), (2) application method of cleaning agent (directly onto surface or indirectly onto a wipe) and (3) use of isopropyl alcohol after cleaning agent application. Known concentrations of antineoplastic drugs (either methotrexate or cyclophosphamide) were placed on a stainless steel swatch and then, systematically, each of the three cleaning variables was tested. Surface wipes were collected and quantified using high-performance liquid chromatography-tandem mass spectrometry to determine the percent residual of drug remaining (with 100% being complete elimination of the drug). No one single cleaning agent proved to be effective in completely eliminating all drug contamination. The method of application had minimal effect on the amount of drug residual. In general, application of isopropyl alcohol after the use of cleaning agent further reduced the level of drug contamination although measureable levels of drug were still found in some cases.
Malysheva, A G; Abramov, E G
2006-01-01
The high concentrations of lead were reveled in the air and dust of some premises and on the filters of a combined air-conditioning extract-and-input system in the high-rise office buildings located in the ecologically lead favorable environment. The dust content of lead in some premises on the first floors dust was as high as 200 mg/kg, which was more than 6 times higher than that in the soil at the highway near the office buildings. The use of new technologies and devices for cleaning and optimizing the air in the premises requires analytical studies to assess the quality of the environment, by taking into account the optimal conditions of their operation.
Costs and Risks of Continuous Purges for Instruments
NASA Technical Reports Server (NTRS)
Secunda, M.; De Garcia, K. Montt
2018-01-01
As instruments are built, tested, and launched, they are exposed to environments that have various levels of cleanliness. Often, Scientists and Contamination Control Engineers specify a purge to mitigate the instrument's exposure to a non-clean environment, protect sensitive optics from a specific threat, such as water, or as insurance against things going wrong in a clean environment. The cost of the purge, in effort, dollars and risk, is often understated when the requirements are being established, and the need for purge is not clearly justifiable. This paper will more clearly define some of the costs and risks associated with the continuous purging of instruments during the course of building, testing and launching instruments.
Innovative Commercialization Efforts Underway at the National Renewable Energy Laboratory
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheesbrough, Kate; Bader, Meghan
New clean energy and energy efficiency technology solutions hold the promise of significant reductions in energy consumption. However, proven barriers for these technologies, including the technological and commercialization valleys of death, result in promising technologies falling to the wayside. To address these gaps, NREL's Innovation & Entrepreneurship Center designs and manages advanced programs aimed at supporting the development and commercialization of early stage clean energy technologies with the goal of accelerating new technologies to market. These include: Innovation Incubator (IN2) in partnership with Wells Fargo: this technology incubator supports energy efficiency building-related startups to overcome market gaps by providing accessmore » to technical support at NREL; Small Business Voucher Pilot: this program offers paid vouchers for applicants to access a unique skill, capability, or facility at any of the 17 DOE National Laboratories to bring next-generation clean energy technologies to market; Energy Innovation Portal: NREL designed and developed the Energy Innovation Portal, providing access to EERE focused intellectual property available for licensing from all of the DOE National Laboratories; Lab-Corps: Lab-Corps aims to better train and empower national lab researchers to understand market drivers and successfully transition their discoveries into high-impact, real world technologies in the private sector; Incubatenergy Network: the Network provides nationwide coordination of clean energy business incubators, share best practices, support clean energy entrepreneurs, and help facilitate a smoother transition to a more sustainable clean energy economy; Industry Growth Forum: the Forum is the perfect venue for clean energy innovators to maximize their exposure to receptive capital and strategic partners. Since 2003, presenting companies have collectively raised more than $5 billion in growth financing.« less
Exploring the consequences of climate change for indoor air quality
NASA Astrophysics Data System (ADS)
Nazaroff, William W.
2013-03-01
Climate change will affect the concentrations of air pollutants in buildings. The resulting shifts in human exposure may influence public health. Changes can be anticipated because of altered outdoor pollution and also owing to changes in buildings effected in response to changing climate. Three classes of factors govern indoor pollutant levels in occupied spaces: (a) properties of pollutants; (b) building factors, such as the ventilation rate; and (c) occupant behavior. Diversity of indoor conditions influences the public health significance of climate change. Potentially vulnerable subpopulations include not only the young and the infirm but also those who lack resources to respond effectively to changing conditions. Indoor air pollutant levels reflect the sum of contributions from indoor sources and from outdoor pollutants that enter with ventilation air. Pollutant classes with important indoor sources include the byproducts of combustion, radon, and volatile and semivolatile organic compounds. Outdoor pollutants of special concern include particulate matter and ozone. To ensure good indoor air quality it is important first to avoid high indoor emission rates for all pollutants and second to ensure adequate ventilation. A third factor is the use of air filtration or air cleaning to achieve further improvements where warranted. Reprinted with permission from Climate Change, the Indoor Environment, and Health (2011) by the National Academy of Sciences, Courtesy of the National Academies Press, Washington, DC.
Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility.
Santos-Junior, Aires G; Ferreira, Adriano M; Frota, Oleci P; Rigotti, Marcelo A; Barcelos, Larissa da S; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G; R Furlan, Mara C
2018-01-01
Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle ( p =0.007) and the toilet bowl ( p =0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect ( p =0.04). The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraus, Yvonne X.
2014-02-14
RePower Bainbridge and Bremerton (RePower) is a residential energy-efficiency and conservation program designed to foster a sustainable, clean, and renewable energy economy. The program was a 3.5 year effort in the cities of Bainbridge Island and Bremerton, Washington, to conserve and reduce energy use, establish a trained home performance trade ally network, and create local jobs. RePower was funded through a $4.8 million grant from the US Department of Energy, Better Buildings Program. The grant’s performance period was August 1, 2010 through March 30, 2014.
Hard surface biocontrol in hospitals using microbial-based cleaning products.
Vandini, Alberta; Temmerman, Robin; Frabetti, Alessia; Caselli, Elisabetta; Antonioli, Paola; Balboni, Pier Giorgio; Platano, Daniela; Branchini, Alessio; Mazzacane, Sante
2014-01-01
Healthcare-Associated Infections (HAIs) are one of the most frequent complications occurring in healthcare facilities. Contaminated environmental surfaces provide an important potential source for transmission of many healthcare-associated pathogens, thus indicating the need for new and sustainable strategies. This study aims to evaluate the effect of a novel cleaning procedure based on the mechanism of biocontrol, on the presence and survival of several microorganisms responsible for HAIs (i.e. coliforms, Staphyloccus aureus, Clostridium difficile, and Candida albicans) on hard surfaces in a hospital setting. The effect of microbial cleaning, containing spores of food grade Bacillus subtilis, Bacillus pumilus and Bacillus megaterium, in comparison with conventional cleaning protocols, was evaluated for 24 weeks in three independent hospitals (one in Belgium and two in Italy) and approximately 20000 microbial surface samples were collected. Microbial cleaning, as part of the daily cleaning protocol, resulted in a reduction of HAI-related pathogens by 50 to 89%. This effect was achieved after 3-4 weeks and the reduction in the pathogen load was stable over time. Moreover, by using microbial or conventional cleaning alternatively, we found that this effect was directly related to the new procedure, as indicated by the raise in CFU/m2 when microbial cleaning was replaced by the conventional procedure. Although many questions remain regarding the actual mechanisms involved, this study demonstrates that microbial cleaning is a more effective and sustainable alternative to chemical cleaning and non-specific disinfection in healthcare facilities. This study indicates microbial cleaning as an effective strategy in continuously lowering the number of HAI-related microorganisms on surfaces. The first indications on the actual level of HAIs in the trial hospitals monitored on a continuous basis are very promising, and may pave the way for a novel and cost-effective strategy to counteract or (bio)control healthcare-associated pathogens.
Hard Surface Biocontrol in Hospitals Using Microbial-Based Cleaning Products
Vandini, Alberta; Temmerman, Robin; Frabetti, Alessia; Caselli, Elisabetta; Antonioli, Paola; Balboni, Pier Giorgio; Platano, Daniela; Branchini, Alessio; Mazzacane, Sante
2014-01-01
Background Healthcare-Associated Infections (HAIs) are one of the most frequent complications occurring in healthcare facilities. Contaminated environmental surfaces provide an important potential source for transmission of many healthcare-associated pathogens, thus indicating the need for new and sustainable strategies. Aim This study aims to evaluate the effect of a novel cleaning procedure based on the mechanism of biocontrol, on the presence and survival of several microorganisms responsible for HAIs (i.e. coliforms, Staphyloccus aureus, Clostridium difficile, and Candida albicans) on hard surfaces in a hospital setting. Methods The effect of microbial cleaning, containing spores of food grade Bacillus subtilis, Bacillus pumilus and Bacillus megaterium, in comparison with conventional cleaning protocols, was evaluated for 24 weeks in three independent hospitals (one in Belgium and two in Italy) and approximately 20000 microbial surface samples were collected. Results Microbial cleaning, as part of the daily cleaning protocol, resulted in a reduction of HAI-related pathogens by 50 to 89%. This effect was achieved after 3–4 weeks and the reduction in the pathogen load was stable over time. Moreover, by using microbial or conventional cleaning alternatively, we found that this effect was directly related to the new procedure, as indicated by the raise in CFU/m2 when microbial cleaning was replaced by the conventional procedure. Although many questions remain regarding the actual mechanisms involved, this study demonstrates that microbial cleaning is a more effective and sustainable alternative to chemical cleaning and non-specific disinfection in healthcare facilities. Conclusions This study indicates microbial cleaning as an effective strategy in continuously lowering the number of HAI-related microorganisms on surfaces. The first indications on the actual level of HAIs in the trial hospitals monitored on a continuous basis are very promising, and may pave the way for a novel and cost-effective strategy to counteract or (bio)control healthcare-associated pathogens. PMID:25259528
CPV performance versus soiling effects: Cleaning policies
NASA Astrophysics Data System (ADS)
Sanchez, D.; Trujillo, P.; Martinez, M.; Ferrer, J. P.; Rubio, F.
2012-10-01
In order to improve the performance of the CPV Plants in a cost effective way it is important to define the best cleaning policies, analyzing the effect of soiling in the surface of CPV modules. The energy generation of a CPV technology based in Fresnel Lens improves up to 7% when the surface of the module is cleaned. Some experimental measurements have been carried out over CPV modules and a model has been defined to analyze what is the best cleaning policy for that Technology in Puertollano. The power losses because of soiling and the critical time until the power losses stabilizes are obtained from the measurements; they are used as an input for the simulation. Using an established cleaning cost and the feeding tariff from Spain in 2007 it has been obtained that cleaning only reports a profit during the summer. The conclusion of the work is that the cleaning tasks have to be carefully planned together with the meteorological forecast in order to maximize the investment made in the cleaning.
Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials
NASA Technical Reports Server (NTRS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
[Study on assistant cleaning of ultrasound for the ultrafiltration membrane].
Zhang, Guojun; Liu, Zhongzhou
2003-11-01
The effects of ultrasounds with different frequency on membrane performance were investigated in this paper. The experimental results show that there were nearly no effects of 20 W ultrasound on membrane retention coefficient, but it decreased seriously when the ultrasound power was above 30 W. On the basis of these results, low frequency ultrasound (20 W) was introduced to assist the chemical cleaning in the ultrafiltration process of wastewater from bank note printing works. The cleaning time could be shortened from 20-30 min to 5 min by the ultra-liberation and ultra-blend effects of ultrasound, therefore, the cleaning efficiency was highly improved. However, the fouling substances could not be cleaned entirely in the simple physical cleaning process by SEM analysis.
Limonene and tetrahydrofurfurly alcohol cleaning agent
Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.
1997-10-21
The present invention is a tetrahydrofurfuryl alcohol and limonene cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.
Limonene and tetrahydrofurfuryl alcohol cleaning agent
Bohnert, G.W.; Carter, R.D.; Hand, T.E.; Powers, M.T.
1997-10-21
The present invention is a tetrahydrofurfuryl alcohol and limonene cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.
Pegasus ICON Spacecraft Mate to Separation System
2018-05-09
Technicians prepare NASA's Ionospheric Connection Explorer (ICON) to be attached to the spacecraft separation system May 9, 2018, in a clean room inside Building 1555 at Vandenberg Air Force Base in California. The explorer will launch on June 15, 2018, from Kwajalein Atoll in the Marshall Islands (June 14 in the continental United States) on Orbital ATK's Pegasus XL rocket, which is attached to the company's L-1011 Stargazer aircraft. ICON will study the frontier of space - the dynamic zone high in Earth's atmosphere where terrestrial weather from below meets space weather above. The explorer will help determine the physics of Earth's space environment and pave the way for mitigating its effects on our technology, communications systems and society.
Pegasus ICON Spacecraft Mate to Separation System
2018-05-09
Technicians secure NASA's Ionospheric Connection Explorer (ICON) on the spacecraft separation system May 9, 2018, in a clean room inside Building 1555 at Vandenberg Air Force Base in California. The explorer will launch on June 15, 2018, from Kwajalein Atoll in the Marshall Islands (June 14 in the continental United States) on Orbital ATK's Pegasus XL rocket, which is attached to the company's L-1011 Stargazer aircraft. ICON will study the frontier of space - the dynamic zone high in Earth's atmosphere where terrestrial weather from below meets space weather above. The explorer will help determine the physics of Earth's space environment and pave the way for mitigating its effects on our technology, communications systems and society.
Pegasus ICON Spacecraft Move Into Cleanroom
2018-05-01
Technicians prepare NASA's Ionospheric Connection Explorer (ICON) for its move to a clean room on May 4, 2018, inside Building 1555 at Vandenberg Air Force Base in California. The explorer will launch on June 15, 2018, from Kwajalein Atoll in the Marshall Islands (June 14 in the continental United States) on Orbital ATK's Pegasus XL rocket, which is attached to the company's L-1011 Stargazer aircraft. ICON will study the frontier of space - the dynamic zone high in Earth's atmosphere where terrestrial weather from below meets space weather above. The explorer will help determine the physics of Earth's space environment and pave the way for mitigating its effects on our technology, communications systems and society.
Solar Energy: Its Technologies and Applications
DOE R&D Accomplishments Database
Auh, P. C.
1978-06-01
Solar heat, as a potential source of clean energy, is available to all of us. Extensive R and D efforts are being made to effectively utilize this renewable energy source. A variety of different technologies for utilizing solar energy have been proven to be technically feasible. Here, some of the most promising technologies and their applications are briefly described. These are: Solar Heating and Cooling of Buildings (SHACOB), Solar Thermal Energy Conversion (STC), Wind Energy Conversion (WECS), Bioconversion to Fuels (BCF), Ocean Thermal Energy Conversion (OTEC), and Photovoltaic Electric Power Systems (PEPS). Special emphasis is placed on the discussion of the SHACOB technologies, since the technologies are being expeditiously developed for the near commercialization.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.
2006-10-01
Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and buildingmore » confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated with increased headache (OR=1.6). Fair or poor condition of duct liner was associated with increased upper respiratory symptoms (OR=1.4). Most of the many potential risk factors assessed here had not been investigated previously, and associations found with single symptoms may have been by chance, including several associations that were the reverse of expected. Risk factors newly identified in these analyses that deserve attention include outdoor air intakes less than 60 m above the ground, lack of operable windows, poorly maintained humidification systems, and lack of scheduled inspection for HVAC systems. Infrequent cleaning of cooling coils and drain pans were associated with increases in several symptoms in these as well as prior analyses of BASE data. Replication of these findings is needed, using more objective measurements of both exposure and health response. Confirmation of the specific HVAC factors responsible for increased symptoms in buildings, and development of prevention strategies could have major public health and economic benefits worldwide.« less
NASA Astrophysics Data System (ADS)
Majerek, Dariusz; Guz, Łukasz; Suchorab, Zbigniew; Łagód, Grzegorz; Sobczuk, Henryk
2017-07-01
Mold that develops on moistened building barriers is a major cause of the Sick Building Syndrome (SBS). Fungal contamination is normally evaluated using standard biological methods which are time-consuming and require a lot of manual labor. Fungi emit Volatile Organic Compounds (VOC) that can be detected in the indoor air using several techniques of detection e.g. chromatography. VOCs can be also detected using gas sensors arrays. All array sensors generate particular voltage signals that ought to be analyzed using properly selected statistical methods of interpretation. This work is focused on the attempt to apply statistical classifying models in evaluation of signals from gas sensors matrix to analyze the air sampled from the headspace of various types of the building materials at different level of contamination but also clean reference materials.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, T.
2016-05-20
ZionSolutions is in the process of decommissioning the Zion Nuclear Power Station (ZNPS). After decommissioning is completed, the site will contain two reactor Containment Buildings, the Fuel Handling Building and Transfer Canals, Auxiliary Building, Turbine Building, Crib House/Forebay, and a Waste Water Treatment Facility that have been demolished to a depth of 3 feet below grade. Additional below ground structures remaining will include the Main Steam Tunnels and large diameter intake and discharge pipes. These additional structures are not included in the modeling described in this report, but the inventory remaining (expected to be very low) will be included withmore » one of the structures that are modeled as designated in the Zion Station Restoration Project (ZSRP) License Termination Plan (LTP). The remaining underground structures will be backfilled with clean material. The final selection of fill material has not been made.« less
Construction, Testing, and Analysis of Radon Mitigation System
NASA Astrophysics Data System (ADS)
Jardin, Dan; Schnee, Richard; CDMS Collaboration
2011-10-01
The search for dark matter or other rare events such as neutrinoless double-beta decay is difficult in the presence of background radiation such as the alpha and beta emissions from the 222Rn decay chain. In order to reduce the radioactive background from Rn-daughters, an ultra-low radon clean room is being built at Syracuse University. A vacuum-swing adsorption system is used to mitigate the radon. Air flows through one of two tanks filled with charcoal that the radon adsorbs to, allowing the filtered air to pass into the clean room. Computer-controlled valves direct the airflow so that one tank filters the air while the other tank is purged of radon by circulating a small fraction of the cleaned airflow back through the tank at low pressure. The durations, pressures, and flow rates of each stage of building pressure, filtering, releasing pressure, and purging in the tanks are optimized in order to maximize the reduction of radon from the air. Professor.
Precise Th/U-dating of small and heavily coated samples of deep sea corals
NASA Astrophysics Data System (ADS)
Lomitschka, Michael; Mangini, Augusto
1999-07-01
Marine carbonate skeletons like deep-sea corals are frequently coated with iron and manganese oxides/hydroxides which adsorb additional thorium and uranium out of the sea water. A new cleaning procedure has been developed to reduce this contamination. In this further cleaning step a solution of Na 2EDTA (Na 2H 2T B) and ascorbic acid is used which composition is optimised especially for samples of 20 mg of weight. It was first tested on aliquots of a reef-building coral which had been artificially contaminated with powdered ferromanganese nodule. Applied on heavily contaminated deep-sea corals (scleractinia), it reduced excess 230Th by another order of magnitude in addition to usual cleaning procedures. The measurement of at least three fractions of different contamination, together with an additional standard correction for contaminated carbonates results in Th/U-ages corrected for the authigenic component. A good agreement between Th/U- and 14C-ages can be achieved even for extremely coated corals.
As part of a Department of Defense project, the US Environmental Protection Agency was responsible for designing, building and field operating a pilot-scale pervaporation unit. The field site ws an active dry cleaning facility on the grounds of Marine Corps Base Camp Lejeune in J...
Clean Energy for the Commonwealth Powered by UMass
2009-04-15
Nanomagnetics Zeolite membranes Polymer-inorganic nanocomposites MEMS Nanostructured catalysts Plant Biotechnology Biochem., Cell wall struct., Agronomy Crambe...power management Low-power device networks Energy scavenging Flame Modeling Combustion chemistry Molecular-beam mass spectrometry Building Design...Thayumanavan, PhD. UMass Amherst Professor of Chemistry and Director, Fueling the Future Center for Chemical Innovation – Paul Osenar, PhD. Chief
Our Transforming Energy Economy: Pathways to a Decarbonized Future -
a clean energy future. For example, JISEA's impacts can be seen in its growing natural gas research example, JISEA hosted the NG-RE 360 Degrees of Opportunity Forum, a series of workshops in different assets are one example, such as "smart" buildings that benefit both from solar photovoltaic
Sustainability and Higher Education, a [Hypothetical] Love Story
ERIC Educational Resources Information Center
Wagner, Lindsay Eva
2013-01-01
It is quite clear that sustainability is here to stay, but in many cases one has yet to determine what it actually is. The buzz words and issues--solar panels, wind turbines, recycling, green cleaning, energy management, green buildings, green products, public transportation, and carbon neutrality to mention a few--have all been part of the…
3 CFR 9032 - Proclamation 9032 of September 30, 2013. National Energy Action Month, 2013
Code of Federal Regulations, 2014 CFR
2014-01-01
... reduce carbon pollution, and we must build global markets for new advanced technologies. If we take these... must invest in the technologies of the future and fund breakthrough research to make these technologies... world in creating green jobs and technologies that are vital to both a clean energy future and the fight...
The U.S. EPA considers tetrachloroethene (perc) a problematic pollutant in urban areas. The New York State Department of Health (NYSDOH) has documented high levels of perc in the indoor air of apartments located in the same buildings as dry cleaning facilities in New York Stat...
A New Model for American Colleges Abroad: Quiet Partner
ERIC Educational Resources Information Center
Mills, Andrew
2009-01-01
For the past two years, a steady stream of visitors from the Massachusetts Institute of Technology (MIT) has made the roughly 7,000-mile trek from Cambridge to Abu Dhabi to help build what aspires to be the first graduate-level research university devoted entirely to fostering renewable, clean, and sustainable sources of energy. Set to open this…
7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.
Code of Federal Regulations, 2010 CFR
2010-01-01
... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...
7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.
Code of Federal Regulations, 2012 CFR
2012-01-01
... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...
7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.
Code of Federal Regulations, 2011 CFR
2011-01-01
... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...
7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.
Code of Federal Regulations, 2014 CFR
2014-01-01
... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...
7 CFR 56.76 - Minimum facility and operating requirements for shell egg grading and packing plants.
Code of Federal Regulations, 2013 CFR
2013-01-01
... or rodents. (3) Buildings shall be of sound construction so as to prevent, insofar as practicable... cleaned at the end of each operating day. (5) The floors, walls, ceilings, partitions, and other parts of... reflection of light that interfere with, or prohibit the accurate quality determination of eggs in the...
Healthy Schools: Lessons for a Clean Educational Environment
ERIC Educational Resources Information Center
US Environmental Protection Agency, 2008
2008-01-01
More than 53 million children and 6 million adults in the United States spend their days in elementary and secondary schools. Reducing environmental risks inside these buildings is critical to maintaining the public health. Almost all of New England's children will spend a large portion of their childhood in school. To help children stay healthy,…
A field study was performed to evaluate indoor air concentrations and vapor intrusion (VI) of tetrachloroethylene (PCE) and other chlorinated solvents at a commercial retail site in Dallas, TX. The building is approximately 40 years old and once housed a dry cleaning operation. R...
40 CFR 63.4682 - What parts of my plant does this subpart cover?
Code of Federal Regulations, 2010 CFR
2010-07-01
... Products What This Subpart Covers § 63.4682 What parts of my plant does this subpart cover? (a) This... surface coating of wood building products: (1) All coating operations as defined in § 63.4781; (2) All storage containers and mixing vessels in which coatings, thinners, and cleaning materials are stored or...
Do as the Romans: Construct an Aqueduct! Grades 6-8.
ERIC Educational Resources Information Center
Rushton, Erik; Ryan, Emily; Swift, Charles
In this activity, students work with specified materials to create aqueduct components to transport two liters of water across a short distance in the classroom. The goal is to build an aqueduct that will supply Aqueductis, a Roman city, with clean water for private homes, public baths, and glorious fountains. By introducing various ideas and…
Neutron Imaging for Selective Laser Melting Inconel Hardware with Internal Passages
NASA Technical Reports Server (NTRS)
Tramel, Terri L.; Norwood, Joseph K.; Bilheux, Hassina
2014-01-01
Additive Manufacturing is showing great promise for the development of new innovative designs and large potential life cycle cost reduction for the Aerospace Industry. However, more development work is required to move this technology into space flight hardware production. With selective laser melting (SLM), hardware that once consisted of multiple, carefully machined and inspected pieces, joined together can be made in one part. However standard inspection techniques cannot be used to verify that the internal passages are within dimensional tolerances or surface finish requirements. NASA/MSFC traveled to Oak Ridge National Lab's (ORNL) Spallation Neutron Source to perform some non-destructive, proof of concept imaging measurements to assess the capabilities to understand internal dimensional tolerances and internal passages surface roughness. This presentation will describe 1) the goals of this proof of concept testing, 2) the lessons learned when designing and building these Inconel 718 test specimens to minimize beam time, 3) the neutron imaging test setup and test procedure to get the images, 4) the initial results in images, volume and a video, 4) the assessment of using this imaging technique to gather real data for designing internal flow passages in SLM manufacturing aerospace hardware, and lastly 5) how proper cleaning of the internal passages is critically important. In summary, the initial results are very promising and continued development of a technique to assist in SLM development for aerospace components is desired by both NASA and ORNL. A plan forward that benefits both ORNL and NASA will also be presented, based on the promising initial results. The initial images and volume reconstruction showed that clean, clear images of the internal passages geometry are obtainable. These clear images of the internal passages of simple geometries will be compared to the build model to determine any differences. One surprising result was that a new cleaning process was used on these simply geometric specimens that resulted in what appears to be very smooth internal surfaces, when compared to other aerospace hardware cleaning methods.
Effectiveness of Surface Cleaning and Disinfection in a Brazilian Healthcare Facility
Santos-Junior, Aires G.; Ferreira, Adriano M.; Frota, Oleci P.; Rigotti, Marcelo A.; Barcelos, Larissa da S.; Lopes de Sousa, Alvaro Francisco; de Andrade, Denise; Guerra, Odanir G.; R. Furlan, Mara C.
2018-01-01
Background: Failures in the processes of cleaning and disinfecting health service surfaces may result in the spread and transfer of pathogens that are often associated with healthcare-related infections and outbreaks. Aims: To assess the effectiveness of environmental surface cleaning and disinfection in a hospital clinic. Method: The study was conducted in a nursing ward with 45 beds. A total of 80 samples from five high-touch surfaces were evaluated before and after cleaning and disinfection, using the following methods: visual inspection, adenosine triphosphate bioluminescence assay, aerobic colony count, Staphylococcus aureus colony count, and evaluation of resistance to methicillin. The data analysis used nonparametric comparative and correlative tests to observe any differences in the pre- and post- cleaning and disinfection results for the surfaces assessed. Results: Effective cleaning and disinfection had a significant effect on only two surfaces when measured for the presence of adenosine triphosphate, the inner bathroom door handle (p=0.007) and the toilet bowl (p=0.01). When evaluated for Staphylococcus aureus colony count, the toilet flush handle also demonstrated a significant effect (p=0.04). Conclusion: The effectiveness of cleaning and disinfection of the surfaces tested was not satisfactory. An educational intervention is recommended for the cleaning and disinfection staff and the nursing team at the healthcare facility. Relevance to Clinical Practice: The data in the study revealed that daily hospital cleaning and disinfection in the sampled sites are not sufficient in medical and surgical wards. Hospital cleanliness must be reevaluated from the point of view of materials, such as an adequate supply of clean cloths, in addition to establishing more precise cleanliness protocols and accurate monitoring systems. PMID:29643951
Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials
NASA Technical Reports Server (NTRS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Evaluation of Various Cleaning Methods to Remove Bacillus Spores from Spacecraft Hardware Materials
NASA Astrophysics Data System (ADS)
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-09-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm × 2.5 cm) were precleaned and inoculated with 5.8 × 103 cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Evaluation of various cleaning methods to remove bacillus spores from spacecraft hardware materials.
Venkateswaran, Kasthuri; Chung, Shirley; Allton, Judith; Kern, Roger
2004-01-01
A detailed study was made of the biological cleaning effectiveness, defined in terms of the ability to remove bacterial spores, of a number of methods used to clean hardware surfaces. Aluminum (Al 6061) and titanium (Ti 6Al-4V) were chosen for the study as they were deemed the two materials most likely to be used in spacecraft extraterrestrial sampler construction. Metal coupons (1 cm x 2.5 cm) were precleaned and inoculated with 5.8 x 10(3) cultivable Bacillus subtilis spores, which are commonly found on spacecraft surfaces and in the assembly environments. The inoculated coupons were subsequently cleaned using: (1) 70% isopropyl alcohol wipe; (2) water wipe; (3) multiple-solvent flight-hardware cleaning procedures used at the Jet Propulsion Laboratory (JPL); (4) Johnson Space Center-developed ultrapure water rinse; and (5) a commercial, semi-aqueous, multiple-solvent (SAMS) cleaning process. The biological cleaning effectiveness was measured by agar plate assay, sterility test (growing in liquid media), and epifluorescent microscopy. None of the cleaning protocols tested completely removed viable spores from the surface of the aluminum. In contrast, titanium was capable of being cleaned to sterility by two methods, the JPL standard and the commercial SAMS cleaning process. Further investigation showed that the passivation step employed in the JPL standard method is an effective surface sterilant on both metals but not compatible with aluminum. It is recommended that titanium (Ti 6Al-4V) be considered superior to aluminum (Al 6061) for use in spacecraft sampling hardware, both for its potential to be cleaned to sterilization and for its ability to withstand the most effective cleaning protocols.
Limonene and tetrahydrofurfuryl alcohol cleaning agent
Bohnert, George W.; Carter, Richard D.; Hand, Thomas E.; Powers, Michael T.
1996-05-07
The present invention is a tetrahydrofurfuryl alcohol and limonene or terpineol cleaning agent and method for formulating and/or using the cleaning agent. This cleaning agent effectively removes both polar and nonpolar contaminants from various electrical and mechanical parts and is readily used without surfactants, thereby reducing the need for additional cleaning operations. The cleaning agent is warm water rinsable without the use of surfactants. The cleaning agent can be azeotropic, enhancing ease of use in cleaning operations and ease of recycling.
Ultrasonic frequency selection for aqueous fine cleaning
NASA Technical Reports Server (NTRS)
Becker, Joann F.
1995-01-01
A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Division of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation, frequency vs. cleaning effectiveness, the two types of transducers, and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.
Ultrasonic frequency selection for aqueous fine cleaning
NASA Technical Reports Server (NTRS)
Becker, Joann F.
1994-01-01
A study was conducted to evaluate ultrasonic cleaning systems for precision cleaning effectiveness for oxygen service hardware. This evaluation was specific for Rocketdyne Div. of Rockwell Aerospace alloys and machining soils. Machining lubricants and hydraulic fluid were applied as soils to standardized complex test specimens designed to simulate typical hardware. The study consisted of tests which included 20, 25, 30, 40, 50, and 65 kHz ultrasonic cleaning systems. Two size categories of cleaning systems were evaluated, 3- to 10-gal laboratory size tanks and 35- to 320-gal industrial size tanks. The system properties of cavitation; frequency vs. cleaning effectiveness; the two types of transducers; and the power level of the system vs. size of the cleaning tank were investigated. The data obtained from this study was used to select the ultrasonic tanks for the aqueous fine clean facility installed at Rocketdyne.
Laser cleaning of the contaminations on the surface of tire mould
NASA Astrophysics Data System (ADS)
Ye, Yayun; Jia, Baoshen; Chen, Jing; Jiang, Yilan; Tang, Hongping; Wang, Haijun; Luan, Xiaoyu; Liao, Wei; Zhang, Chuanchao; Yao, Caizhen
2017-07-01
During the manufacturing of tires, surface pollutants on tire mould will lead to the production of unqualified tires. Tire moulds need to be regularly cleaned. Laser cleaning is recognized as a non-destructive, effective, precise and environmental friendly method. In this paper, laser cleaning was used to remove contaminants on tire mould surface. First, laser induced damage experiments were performed. The results showed that the roughness and hardness of the cast steel sample surface seldom changed under the energy range of 140.1-580.2 mJ laser irradiation 1 pulse and the energy range of 44.7-168.9 mJ laser irradiation 100 pulses. In the laser cleaning experiments, the cleaning thresholds and the optimal cleaning parameters were obtained. Results indicated that laser cleaning was safe and effective for tire mould contamination removal.
Identification of sewer pipes to be cleaned for reduction of CSO pollutant load.
Nagaiwa, Akihiro; Settsu, Katsushi; Nakajima, Fumiyuki; Furumai, Hiroaki
2007-01-01
To reduce the CSO (Combined Sewer Overflow) pollutant discharge, one of the effective options is cleaning of sewer pipes before rainfall events. To maximize the efficiency, identification of pipes to be cleaned is necessary. In this study, we discussed the location of pipe deposit in dry weather in a combined sewer system using a distributed model and investigated the effect of pipe cleaning to reduce the pollutant load from the CSO. First we simulated the dry weather flow in a combined sewer system. The pipe deposit distribution in the network was estimated after 3 days of dry weather period. Several specific pipes with structural defect and upper end pipes tend to have an accumulation of deposit. Wet weather simulations were conducted with and without pipe cleaning in rainfall events with different patterns. The SS loads in CSO with and without the pipe cleaning were compared. The difference in the estimated loads was interpreted as the contribution of wash-off in the cleaned pipe. The effect of pipe cleaning on reduction of the CSO pollutant load was quantitatively evaluated (e.g. the cleaning of one specific pipe could reduce 22% of total CSO load). The CSO simulations containing pipe cleaning options revealed that identification of pipes with accumulated deposit using the distributed model is very useful and informative to evaluate the applicability of pipe cleaning option for CSO pollutant reduction.
Employing ASHRAE Standard 62-1989 in urban building environments
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meckler, M.
1991-01-01
Indoor air quality (IAQ) is a result of a complex relationship between the contamination sources in a building, the ventilation rate, and the dilution of the indoor air contaminant concentrations with outdoor air. This complex relationship is further complicated by outdoor sources used for dilution air and pollution sinks in a building which may modify or remove contaminants. This paper reports that the factors influencing IAQ in a building are: emissions from indoor contamination sources, dilution rate of outdoor ventilation air, quality of the outdoor dilution air, and systems and materials in a building that change the concentrations of contaminants.more » Emissions from contaminant sources in a building are the primary determinant of IAQ. They include building materials, consumer products, cleaners, furnishings, combustion appliances and processes, biological growth from standing water and damp surfaces and building occupants. These factors combined with the emissions from indoor air contamination sources such as synthetic building materials, modern office equipment, and cleaning and biological agents are believed to increase the levels of indoor air contamination. The physiological reactions to these contaminants, coupled with the psychosocial stresses of the modern office environment, and the wide range of human susceptibility to indoor air contaminants led to the classification of acute building sicknesses: sick building syndrome (SBS), building-related illness (BRI), and multiple chemical sensitivity (MCS).« less
Ocean acidification and its potential effects on marine ecosystems.
Guinotte, John M; Fabry, Victoria J
2008-01-01
Ocean acidification is rapidly changing the carbonate system of the world oceans. Past mass extinction events have been linked to ocean acidification, and the current rate of change in seawater chemistry is unprecedented. Evidence suggests that these changes will have significant consequences for marine taxa, particularly those that build skeletons, shells, and tests of biogenic calcium carbonate. Potential changes in species distributions and abundances could propagate through multiple trophic levels of marine food webs, though research into the long-term ecosystem impacts of ocean acidification is in its infancy. This review attempts to provide a general synthesis of known and/or hypothesized biological and ecosystem responses to increasing ocean acidification. Marine taxa covered in this review include tropical reef-building corals, cold-water corals, crustose coralline algae, Halimeda, benthic mollusks, echinoderms, coccolithophores, foraminifera, pteropods, seagrasses, jellyfishes, and fishes. The risk of irreversible ecosystem changes due to ocean acidification should enlighten the ongoing CO(2) emissions debate and make it clear that the human dependence on fossil fuels must end quickly. Political will and significant large-scale investment in clean-energy technologies are essential if we are to avoid the most damaging effects of human-induced climate change, including ocean acidification.
Cleaning Management in Higher Education: Value for Money Study.
ERIC Educational Resources Information Center
Scottish Higher Education Funding Council, Edinburgh.
This report identifies key management issues for senior managers and heads of cleaning departments in developing and reviewing cleaning services to support improvement and enhance cost effectiveness. The cleaning costs incurred by higher education institutions (HEIs) represent 2.7 percent of the total spent nationally on cleaning services for both…
Gomes, Vera; Dionísio, Amélia; Santiago Pozo-Antonio, J
2018-06-01
Graffiti are one of the most severe threats to Stone Cultural Heritage and are most of the times removed after long periods of environmental exposure. This research intends to evaluate the influence of the ageing of the graffitis on the effectiveness of their cleaning. So, comparative studies on unaged and on artificially SO 2 aged samples were conducted. Four graffiti spray colours were applied on a granite stone and cleaned with two chemical commercial cleaners: a solution of KOH and a solution of n-butyl acetate, xylene and alcohol isobutyl. The spray paints (unaged and aged) and cleaning effectiveness were characterized by stereomicroscopy, colour spectrophotometry, adhesion tests, SEM, μEDXRF, XRD and FTIR. The cleaning effectiveness was also evaluated through surface roughness and static contact angle measurements. The alkyd graffiti paints presented greatest resistance under SO 2 rich environments than the polyethylene paint. The aged polyethylene paint showed chemical modifications that resulted in graffiti losses and neo formed mineralogical phases in the surface of the paint. After ageing, the paints became more difficult to clean, showed higher global colour changes and higher residue percentages. No significant roughness variations were detected after chemical cleaning. After the cleaning procedures aged surfaces became more water repellent comparatively to unaged and reference samples. The best cleaning effectiveness was mainly achieved with the potassium hydroxide solution. Copyright © 2017 Elsevier B.V. All rights reserved.
Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?
Kampf, Günter; Fliss, Patricia M; Martiny, Heike
2014-09-16
The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes.
Is peracetic acid suitable for the cleaning step of reprocessing flexible endoscopes?
Kampf, Günter; Fliss, Patricia M; Martiny, Heike
2014-01-01
The bioburden (blood, protein, pathogens and biofilm) on flexible endoscopes after use is often high and its removal is essential to allow effective disinfection, especially in the case of peracetic acid-based disinfectants, which are easily inactivated by organic material. Cleaning processes using conventional cleaners remove a variable but often sufficient amount of the bioburden. Some formulations based on peracetic acid are recommended by manufacturers for the cleaning step. We performed a systematic literature search and reviewed the available evidence to clarify the suitability of peracetic acid-based formulations for cleaning flexible endoscopes. A total of 243 studies were evaluated. No studies have yet demonstrated that peracetic acid-based cleaners are as effective as conventional cleaners. Some peracetic acid-based formulations have demonstrated some biofilm-cleaning effects and no biofilm-fixation potential, while others have a limited cleaning effect and a clear biofilm-fixation potential. All published data demonstrated a limited blood cleaning effect and a substantial blood and nerve tissue fixation potential of peracetic acid. No evidence-based guidelines on reprocessing flexible endoscopes currently recommend using cleaners containing peracetic acid, but some guidelines clearly recommend not using them because of their fixation potential. Evidence from some outbreaks, especially those involving highly multidrug-resistant gram-negative pathogens, indicated that disinfection using peracetic acid may be insufficient if the preceding cleaning step is not performed adequately. Based on this review we conclude that peracetic acid-based formulations should not be used for cleaning flexible endoscopes. PMID:25228941
Laser versus scalpel cleaning of crustose lichens on granite
NASA Astrophysics Data System (ADS)
Rivas, T.; Pozo-Antonio, J. S.; López de Silanes, M. E.; Ramil, A.; López, A. J.
2018-05-01
This paper addresses the evaluation of the cleaning of crustose lichens developing on granite. The evaluation was performed considering the effectiveness of the cleanings and harmfulness exerted on the granite. The laser cleaning of lichen was compared with the most conventional procedure, scalpel. The combination of both procedures was also tested. The study, which was carried out with two different species of crustose lichen, was also focused on the influence of the intrinsic characteristics of the lichen on the effectiveness. The cleanings were evaluated by optic and electronic microscopies, FTIR and colour spectrophotometry. A previous characterization of the lichen and its interaction with the granite using those analytical techniques were also performed. The laser cleaning effectiveness depends on the coverage and the colour of the lichen; also, the prior mechanical weakening of the lichen by scalpel seemed to improve the laser cleaning. The darkest lichen was satisfactorily removed by laser and with the combined cleaning. Conversely, the lightest lichen was more difficult to extract with laser than the darkest lichen, being necessary to apply both methods sequentially. Despite laser and the combination of methods cleaned satisfactorily the surface, they were unable to eliminate the thalli into fissures.
Improving Data Catalogs with Free and Open Source Software
NASA Astrophysics Data System (ADS)
Schweitzer, R.; Hankin, S.; O'Brien, K.
2013-12-01
The Global Earth Observation Integrated Data Environment (GEO-IDE) is NOAA's effort to successfully integrate data and information with partners in the national US-Global Earth Observation System (US-GEO) and the international Global Earth Observation System of Systems (GEOSS). As part of the GEO-IDE, the Unified Access Framework (UAF) is working to build momentum towards the goal of increased data integration and interoperability. The UAF project is moving towards this goal with an approach that includes leveraging well known and widely used standards, as well as free and open source software. The UAF project shares the widely held conviction that the use of data standards is a key ingredient necessary to achieve interoperability. Many community-based consensus standards fail, though, due to poor compliance. Compliance problems emerge for many reasons: because the standards evolve through versions, because documentation is ambiguous or because individual data providers find the standard inadequate as-is to meet their special needs. In addition, minimalist use of standards will lead to a compliant service, but one which is of low quality. In this presentation, we will be discussing the UAF effort to build a catalog cleaning tool which is designed to crawl THREDDS catalogs, analyze the data available, and then build a 'clean' catalog of data which is standards compliant and has a uniform set of data access services available. These data services include, among others, OPeNDAP, Web Coverage Service (WCS) and Web Mapping Service (WMS). We will also discuss how we are utilizing free and open source software and services to both crawl, analyze and build the clean data catalog, as well as our efforts to help data providers improve their data catalogs. We'll discuss the use of open source software such as DataNucleus, Thematic Realtime Environmental Distributed Data Services (THREDDS), ncISO and the netCDF Java Common Data Model (CDM). We'll also demonstrate how we are using free services such as Google Charts to create an easily identifiable visual metaphor which describes the quality of data catalogs. Using this rubric, in conjunction with the ncISO metadata quality rubric, will allow data providers to identify non-compliance issues in their data catalogs, thereby improving data availability to their users and to data discovery systems
Tang, Honghong; Lu, Xiaping; Su, Rui; Liang, Zilu; Mai, Xiaoqin
2017-01-01
Abstract The association between moral purity and physical cleanliness has been widely discussed recently. Studies found that moral threat initiates the need of physical cleanliness, but actual physical cleaning and priming of cleaning have inconsistent effects on subsequent attitudes and behaviors. Here, we used resting-state functional magnetic resonance imaging to explore the underlying neural mechanism of actual physical cleaning and priming of cleaning. After recalling moral transgression with strong feelings of guilt and shame, participants either actually cleaned their faces with a wipe or were primed with cleanliness through viewing its pictures. Results showed that actual physical cleaning reduced the spontaneous brain activities in the right insula and MPFC, regions that involved in embodied moral emotion processing, while priming of cleaning decreased activities in the right superior frontal gyrus and middle frontal gyrus, regions that participated in executive control processing. Additionally, actual physical cleaning also changed functional connectivity between insula/MPFC and emotion related regions, whereas priming of cleaning modified connectivity within both moral and sensorimotor areas. These findings revealed that actual physical cleaning and priming of cleaning led to changes in different brain regions and networks, providing neural evidence for the inconsistent effects of cleanliness on subsequent attitudes and behaviors. PMID:28338887
Tang, Honghong; Lu, Xiaping; Su, Rui; Liang, Zilu; Mai, Xiaoqin; Liu, Chao
2017-07-01
The association between moral purity and physical cleanliness has been widely discussed recently. Studies found that moral threat initiates the need of physical cleanliness, but actual physical cleaning and priming of cleaning have inconsistent effects on subsequent attitudes and behaviors. Here, we used resting-state functional magnetic resonance imaging to explore the underlying neural mechanism of actual physical cleaning and priming of cleaning. After recalling moral transgression with strong feelings of guilt and shame, participants either actually cleaned their faces with a wipe or were primed with cleanliness through viewing its pictures. Results showed that actual physical cleaning reduced the spontaneous brain activities in the right insula and MPFC, regions that involved in embodied moral emotion processing, while priming of cleaning decreased activities in the right superior frontal gyrus and middle frontal gyrus, regions that participated in executive control processing. Additionally, actual physical cleaning also changed functional connectivity between insula/MPFC and emotion related regions, whereas priming of cleaning modified connectivity within both moral and sensorimotor areas. These findings revealed that actual physical cleaning and priming of cleaning led to changes in different brain regions and networks, providing neural evidence for the inconsistent effects of cleanliness on subsequent attitudes and behaviors. © The Author (2017). Published by Oxford University Press.
Deep Energy Retrofit Guidance for the Building America Solutions Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Less, Brennan; Walker, Iain
2015-01-01
The U.S. DOE Building America program has established a research agenda targeting market-relevant strategies to achieve 40% reductions in existing home energy use by 2030. Deep Energy Retrofits (DERs) are part of the strategy to meet and exceed this goal. DERs are projects that create new, valuable assets from existing residences, by bringing homes into alignment with the expectations of the 21st century. Ideally, high energy using, dated homes that are failing to provide adequate modern services to their owners and occupants (e.g., comfortable temperatures, acceptable humidity, clean, healthy), are transformed through comprehensive upgrades to the building envelope, services andmore » miscellaneous loads into next generation high performance homes. These guidance documents provide information to aid in the broader market adoption of DERs.« less
Hall, Lisa; Farrington, Alison; Mitchell, Brett G; Barnett, Adrian G; Halton, Kate; Allen, Michelle; Page, Katie; Gardner, Anne; Havers, Sally; Bailey, Emily; Dancer, Stephanie J; Riley, Thomas V; Gericke, Christian A; Paterson, David L; Graves, Nicholas
2016-03-24
The Researching Effective Approaches to Cleaning in Hospitals (REACH) study will generate evidence about the effectiveness and cost-effectiveness of a novel cleaning initiative that aims to improve the environmental cleanliness of hospitals. The initiative is an environmental cleaning bundle, with five interdependent, evidence-based components (training, technique, product, audit and communication) implemented with environmental services staff to enhance hospital cleaning practices. The REACH study will use a stepped-wedge randomised controlled design to test the study intervention, an environmental cleaning bundle, in 11 Australian hospitals. All trial hospitals will receive the intervention and act as their own control, with analysis undertaken of the change within each hospital based on data collected in the control and intervention periods. Each site will be randomised to one of the 11 intervention timings with staggered commencement dates in 2016 and an intervention period between 20 and 50 weeks. All sites complete the trial at the same time in 2017. The inclusion criteria allow for a purposive sample of both public and private hospitals that have higher-risk patient populations for healthcare-associated infections (HAIs). The primary outcome (objective one) is the monthly number of Staphylococcus aureus bacteraemias (SABs), Clostridium difficile infections (CDIs) and vancomycin resistant enterococci (VRE) infections, per 10,000 bed days. Secondary outcomes for objective one include the thoroughness of hospital cleaning assessed using fluorescent marker technology, the bio-burden of frequent touch surfaces post cleaning and changes in staff knowledge and attitudes about environmental cleaning. A cost-effectiveness analysis will determine the second key outcome (objective two): the incremental cost-effectiveness ratio from implementation of the cleaning bundle. The study uses the integrated Promoting Action on Research Implementation in Health Services (iPARIHS) framework to support the tailored implementation of the environmental cleaning bundle in each hospital. Evidence from the REACH trial will contribute to future policy and practice guidelines about hospital environmental cleaning. It will be used by healthcare leaders and clinicians to inform decision-making and implementation of best-practice infection prevention strategies to reduce HAIs in hospitals. Australia New Zealand Clinical Trial Registry ACTRN12615000325505.
Automated carbon dioxide cleaning system
NASA Technical Reports Server (NTRS)
Hoppe, David T.
1991-01-01
Solidified CO2 pellets are an effective blast media for the cleaning of a variety of materials. CO2 is obtained from the waste gas streams generated from other manufacturing processes and therefore does not contribute to the greenhouse effect, depletion of the ozone layer, or the environmental burden of hazardous waste disposal. The system is capable of removing as much as 90 percent of the contamination from a surface in one pass or to a high cleanliness level after multiple passes. Although the system is packaged and designed for manual hand held cleaning processes, the nozzle can easily be attached to the end effector of a robot for automated cleaning of predefined and known geometries. Specific tailoring of cleaning parameters are required to optimize the process for each individual geometry. Using optimum cleaning parameters the CO2 systems were shown to be capable of cleaning to molecular levels below 0.7 mg/sq ft. The systems were effective for removing a variety of contaminants such as lubricating oils, cutting oils, grease, alcohol residue, biological films, and silicone. The system was effective on steel, aluminum, and carbon phenolic substrates.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stovall, Therese K; Biswas, Kaushik; Song, Bo
In November of 2009, the presidents of China and the U.S. announced the establishment of the Clean Energy Research Center (CERC). This broad research effort is co-funded by both countries and involves a large number of research centers and universities in both countries. One part of this program is focused on improving the energy efficiency of buildings. One portion of the CERC-BEE was focused on building insulation systems. The research objective of this effort was to Identify and investigate candidate high performance fire resistant building insulation technologies that meet the goal of building code compliance for exterior wall applications inmore » green buildings in multiple climate zones. A Joint Work Plan was established between researchers at the China Academy of Building Research and Oak Ridge National Laboratory. Efforts in the first year under this plan focused on information gathering. The objective of this research program is to reduce building energy use in China via improved building insulation technology. In cold regions in China, residents often use inefficient heating systems to provide a minimal comfort level within inefficient buildings. In warmer regions, air conditioning has not been commonly used. As living standards rise, energy consumption in these regions will increase dramatically unless significant improvements are made in building energy performance. Previous efforts that defined the current state of the built environment in China and in the U.S. will be used in this research. In countries around the world, building improvements have typically followed the implementation of more stringent building codes. There have been several changes in building codes in both the U.S. and China within the last few years. New U.S. building codes have increased the amount of wall insulation required in new buildings. New government statements from multiple agencies in China have recently changed the requirements for buildings in terms of energy efficiency and fire safety. A related issue is the degree to which new standards are adopted and enforced. In the U.S., standards are developed using a consensus process, and local government agencies are free to implement these standards or to ignore them. For example, some U.S. states are still using 2003 versions of the building efficiency standards. There is also a great variation in the degree to which the locally adopted standards are enforced in different U.S. cities and states. With a more central process in China, these issues are different, but possible impacts of variable enforcement efficacy may also exist. Therefore, current building codes in China will be compared to the current state of building fire-safety and energy-efficiency codes in the U.S. and areas for possible improvements in both countries will be explored. In particular, the focus of the applications in China will be on green buildings. The terminology of 'green buildings' has different meanings to different audiences. The U.S. research is interested in both new, green buildings, and on retrofitting existing inefficient buildings. An initial effort will be made to clarify the scope of the pertinent wall insulation systems for these applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apol, A.G.
In November 1980, the National Institute for Occupational Safety and Health (NIOSH) received a request for a Health Hazard Evaluation from the Salem Area Family Counseling Service to determine the cause of the adverse health responses (headache, dizziness, irritation of the eyes and throat, dry and sore throat, fatigue, and lethargy) experienced by six of the seven employees in the office. NIOSH conducted an environmental survey on December 29-30, 1980. Due to the persistence of symptoms after the carpets and drapes were steamed cleaned, and the ventilation system cleaned, the firm relocated in another office building. Two months after relocation,more » the symptoms appeared to have disappeared.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nelson, Carl
In the summer of 2006 the Green Institute started the study for the RockTenn paper mill that would evaluate the economics and supply chain reliability of wood waste and other clean biomass as a fuel for the facility. The Green Institute obtained sponsorship from a broad coalition representing the community and the project team included other consultants and university researchers specializing in biomass issues. The final product from the project was a report to: 1) assess the availability of clean biomass fuel for use at the Rock-Tenn site; 2) roughly estimate costs at various annual usage quantities; and 3) developmore » the building blocks for a supply chain procurement plan. The initial report was completed and public presentations on the results were completed in spring of 2007.« less
Clean then Assemble Versus Assemble then Clean: Several Comparisons
NASA Technical Reports Server (NTRS)
Welker, Roger W.
2004-01-01
Cleanliness of manufactured parts and assemblies is a significant issue in many industries including disk drives, semiconductors, aerospace, and medical devices. Clean manufacturing requires cleanroom floor space and cleaning technology that are both expensive to own and expensive to operate. Strategies to reduce these costs are an important consideration. One strategy shown to be effective at reducing costs is to assemble parts into subassemblies and then clean the subassembly, rather than clean the individual parts first and then assemble them. One advantage is that assembly outside of the cleanroom reduces the amount of cleanroom floor space and its associated operating cost premium. A second advantage is that this strategy reduces the number of individual parts that must be cleaned prior to assembly, reducing the number of cleaning baskets, handling and, possibly, reducing the number of cleaners. The assemble then clean strategy also results in a part that is significantly cleaner because contamination generated during the assembly steps are more effectively removed that normally can be achieved by hand wiping after assembly in the cleanroom.
Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.
Ahmad, I; Tansel, B; Mitrani, J D
2001-12-01
Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.
Sonochemical cleaning efficiencies in dental instruments
NASA Astrophysics Data System (ADS)
Tiong, T. Joyce; Walmsley, A. Damien; Price, Gareth J.
2012-05-01
Ultrasound has been widely used for cleaning purposes in a variety of situations, including in dental practice. Cleaning is achieved through a combination of acoustically driven streaming effects and sonochemical effects arising from the production of inertial cavitation in a liquid. In our work, various dental instruments used for endodontic (root canal) treatment have been evaluated for their efficiency in producing sonochemical effects in an in-vitro cleaning environment. The areas where cavitation was produced were mapped by monitoring chemiluminescence from luminol solutions and this was correlated with their cleaning efficiencies - assessed by the ability to bleach a dye, to form an emulsion by mixing immiscible components and also to remove ink from a glass surface. The results showed good correlation (Pearson's coefficient > 0.9) between the cavitation and cleaning efficiencies, suggesting that the former plays an important role in cleaning. The methods developed and the results will be beneficial in endodontics research in order to optimise future root canal instruments and treatments.
Benzotriazole removal on post-Cu CMP cleaning
NASA Astrophysics Data System (ADS)
Jiying, Tang; Yuling, Liu; Ming, Sun; Shiyan, Fan; Yan, Li
2015-06-01
This work investigates systematically the effect of FA/O II chelating agent and FA/O I surfactant in alkaline cleaning solutions on benzotriazole (BTA) removal during post-Cu CMP cleaning in GLSI under the condition of static etching. The best detergent formulation for BTA removal can be determined by optimization of the experiments of single factor and compound cleaning solution, which has been further confirmed experimentally by contact angle (CA) measurements. The resulting solution with the best formulation has been measured for the actual production line, and the results demonstrate that the obtained cleaning solution can effectively and efficiently remove BTA, CuO and abrasive SiO2 without basically causing interfacial corrosion. This work demonstrates the possibility of developing a simple, low-cost and environmentally-friendly cleaning solution to effectively solve the issues of BTA removal on post-Cu CMP cleaning in a multi-layered copper wafer. Project supported by the Major National Science and Technology Special Projects (No. 2009ZX02308).
Yu, Chang Ho; Yiin, Lih-Ming; Fan, Zhi-Hua (Tina); Rhoads, George G.
2014-01-01
Dry steam cleaning, which has gained recent attention as an effective method to reduce house dust mite (HDM) allergen concentration and loading in carpets, was evaluated in this study for its efficacy in lowering levels of polycyclic aromatic hydrocarbons (PAHs) as well as HDM allergens. Fifty urban homes with wail-to-wall carpets, mostly low-income and with known lead contamination, were studied in 2003 and 2004. Two carpet-cleaning interventions were compared: Repeated HEPA (High Efficiency Particulate Air filtered) vacuuming alone and repeated HEPA vacuuming supplemented with dry steam cleaning. Vacuum samples were collected to measure carpet loading of dust and contaminants immediately before and after cleaning. Paired comparisons were conducted to evaluate the effectiveness of the cleaning protocols in reducing the levels of PAHs and HDM allergens in carpets. The results indicated that both cleaning methods substantially reduced the loading of PAHs and HDM allergens as well as dust in carpets (p < 0.0001). The reductions in loading of dust (64.4%), PAHs (69.1%), and HDM allergens (85.5%), by dry steam cleaning plus repetitive HEPA vacuuming were larger than the reductions by regular HEPA vacuuming alone: dust (55.5%), PAHs (58.6%), and HDM allergens (80.8%), although the difference was statistically significant only for dust and PAHs. We conclude that intensive HEPA vacuum cleaning substantially reduced the loading of PAHs and HDM allergens in carpets in these urban homes and that dry steam cleaning added modestly to cleaning effectiveness. PMID:19137159
Sources of propylene glycol and glycol ethers in air at home.
Choi, Hyunok; Schmidbauer, Norbert; Spengler, John; Bornehag, Carl-Gustaf
2010-12-01
Propylene glycol and glycol ether (PGE) in indoor air have recently been associated with asthma and allergies as well as sensitization in children. In this follow-up report, sources of the PGEs in indoor air were investigated in 390 homes of pre-school age children in Sweden. Professional building inspectors examined each home for water damages, mold odour, building's structural characteristics, indoor temperature, absolute humidity and air exchange rate. They also collected air and dust samples. The samples were analyzed for four groups of volatile organic compounds (VOCs) and semi-VOCs (SVOCs), including summed concentrations of 16 PGEs, 8 terpene hydrocarbons, 2 Texanols, and the phthalates n-butyl benzyl phthalate (BBzP), and di(2-ethylhexyl)phthalate (DEHP). Home cleaning with water and mop ≥ once/month, repainting ≥ one room prior to or following the child's birth, and "newest" surface material in the child's bedroom explained largest portion of total variability in PGE concentrations. High excess indoor humidity (g/m³) additionally contributed to a sustained PGE levels in indoor air far beyond several months following the paint application. No behavioral or building structural factors, except for water-based cleaning, predicted an elevated terpene level in air. No significant predictor of Texanols emerged from our analysis. Overall disparate sources and low correlations among the PGEs, terpenes, Texanols, and the phthalates further confirm the lack of confounding in the analysis reporting the associations of the PGE and the diagnoses of asthma, rhinitis, and eczema, respectively.
Secretary Chu Speaks at the 2010 Washington Auto Show
Secretary Chu
2017-12-09
Secretary Chu lays out a roadmap for how the U.S. can lead the world in making the clean vehicles we need at the 2010 Washington Auto Show. He also announced that the Department of Energy had closed on a $1.4 billion loan to Nissan to build the all-electric LEAF in Tennessee and create up to 1,300 American jobs.
New Power Plants Try to Avoid Coal or Scrub It "Clean"
ERIC Educational Resources Information Center
Basken, Paul
2009-01-01
After spending $133-million to build a new award-winning technological gem of a power plant, officials at the University of Massachusetts at Amherst are expecting their fuel bills to rise by $7-million a year. And yet they are very proud of the accomplishment. The reasons for the higher energy costs involve a complicated mix of technology,…
Says Who?: Students Apply Their Critical-Analysis Skills to Fight Town Hall
ERIC Educational Resources Information Center
Trimarchi, Ruth
2002-01-01
For some time the author looked for a tool to let students apply what they are learning about critical analysis in the science classroom to a relevant life experience. The opportunity occurred when a proposal to use environmentally friendly cleaning products in town buildings appeared on the local town meeting agenda. Using a copy of the proposal…
Securing Volunteers to Fix up the School. Research Brief
ERIC Educational Resources Information Center
Johnston, Howard
2011-01-01
How can schools secure volunteers to help fix up the building and grounds? There isn't much research on how to secure volunteers to participate in school clean-ups and fix-ups, but some key ideas can be found in anecdotal examples from many communities around the nation. The first recommendation is that securing volunteers is easier when the…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-02
... technologies used to generate electricity from fossil fuels, including natural gas. Summit proposes to build... feedstock. It would capture, in the form of CO 2 , about 90% of the carbon in the portion of its coal fuel... (Feb. 17, 2009)) (ARRA) appropriated $3.4 billion to DOE for ``Fossil Energy Research and Development...
My School Makes Me Sick: Cheap Solutions to Environmental Problems in Schools.
ERIC Educational Resources Information Center
Wiley, Robert
This paper presents 19 solutions to problems within the school environment: (1) ventilation (e.g., keep the thermostat fan on whenever the room is occupied); (2) filters (e.g., get rid of 20 percent cheap filters); (3) clean the ductwork; (4) avoid car and bus fumes by keeping vehicles 50 feet from the building; (5) sewer vents (vents must…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-26
... Benchmark Engineering Corp., Civil Action No. 10-40131 was lodged with the United States District Court for... requires Defendants to pay a civil penalty of $150,000, perform a Supplemental Environmental Project, and.... Fafard Real Estate and Development Corp., FRE Building Co. Inc., and Benchmark Engineering Corp., D.J...
Report on Progress Toward Security and Stability in Afghanistan
2011-10-01
change. The inauguration in August 2011 of new Canadian -sponsored facilities (classrooms, dormitories, and an extension of the dining facility) and the...temporary buildings, generators, force protection materials, office supplies, cleaning supplies, kitchen supplies, and furniture . Prior to 2010...Afghan companies making tents, and two Afghan companies making furniture in the Kabul area. An estimated 5,000 Afghans, including women, are
Refinery siting workbook: appendices C to O
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
Applicable laws and permits available for the selection and building of petroleum refineries are enclosed. A glossary of pertinent terms is also included. References related to the National Environmental Policy Act, the Clean Air Act, the Federal Water Pollution Control Act, Resource Conservation and Recovery Act, Toxic Substance Control Act, and Wetlands and Coastal Zone are included. Permit information is also presented. (DC)
P.L. 110-140, "Energy Independence and Security Act of 2007" (2007)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2007-12-13
An act to move the United States toward greater energy independence and security, to increase the production of clean renewable fuels, to protect consumers, to increase the efficiency of products, buildings, and vehicles, to promote research on and deploy greenhouse gas capture and storage options, and to improve the energy performance of the Federal Government, and for other purposes.
Branchburg Solar Farm and Carport
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gregory, John
2013-10-23
To meet the goal of becoming a model of green, clean, and efficient consumer of energy, the Township of Branchburg will install of a 250kw solar farm to provide energy for the Township of Branchburg Municipal Building, a 50kw Solar carport to provide power to the Municipal Annex, purchase 3 plug in hybrid-electric vehicles, and install 3 dual-head charging stations.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NSTec Environmental Restoration
2011-04-30
This Corrective Action Plan has been prepared for Corrective Action Unit (CAU) 562, Waste Systems, in accordance with the Federal Facility Agreement and Consent Order (1996; as amended March 2010). CAU 562 consists of 13 Corrective Action Sites (CASs) located in Areas 2, 23, and 25 of the Nevada National Security Site. Site characterization activities were performed in 2009 and 2010, and the results are presented in Appendix A of the Corrective Action Decision Document for CAU 562. The scope of work required to implement the recommended closure alternatives is summarized. (1) CAS 02-26-11, Lead Shot, will be clean closedmore » by removing shot. (2) CAS 02-44-02, Paint Spills and French Drain, will be clean closed by removing paint and contaminated soil. As a best management practice (BMP), asbestos tile will be removed. (3) CAS 02-59-01, Septic System, will be clean closed by removing septic tank contents. As a BMP, the septic tank will be removed. (4) CAS 02-60-01, Concrete Drain, contains no contaminants of concern (COCs) above action levels. No further action is required; however, as a BMP, the concrete drain will be removed. (5) CAS 02-60-02, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. As a BMP, the drain grates and drain pipe will be removed. (6) CAS 02-60-03, Steam Cleaning Drain, will be clean closed by removing contaminated soil. As a BMP, the steam cleaning sump grate and outfall pipe will be removed. (7) CAS 02-60-04, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. (8) CAS 02-60-05, French Drain, will be clean closed by removing contaminated soil. (9) CAS 02-60-06, French Drain, contains no COCs above action levels. No further action is required. (10) CAS 02-60-07, French Drain, requires no further action. The french drain identified in historical documentation was not located during corrective action investigation activities. (11) CAS 23-60-01, Mud Trap Drain and Outfall, will be clean closed by removing sediment from the mud trap. As a BMP, the mud trap and outfall pipe will be removed. (12) CAS 23-99-06, Grease Trap, will be clean closed by removing sediment from the grease trap and backfilling the grease trap with grout. (13) CAS 25-60-04, Building 3123 Outfalls, will be clean closed by removing contaminated soil and the sludge-containing outfall pipe.« less
Better kitchens and toilets: both needed for better health.
Ravindra, Khaiwal; Smith, Kirk R
2018-05-01
Both poor water, sanitation, hygiene (WaSH) and household air pollution (HAP) adversely affect the health of millions of people each year around the globe and specifically in developing countries. The objective of current work is to highlight the importance of HAP in parallel to WaSH for decision making to achieve better health specially in developing countries. There are examples, where developing countries are strengthening efforts to tackle the issue of poor water and sanitation such as 'Clean India Mission' was recently launched by the Government of India. However, there is lack of actions to address the issue related to HAP-to extend the coverage of clean fuel, efficient stoves and ventilated kitchens to the deprived population under the 'Clean India Mission'. Most of the rural household and urban slums in developing countries have only a single room, where people cook and sleep. This leads them to exposure to toxic HAP, which can be minimized by developing country specific indoor air quality guidelines and action framework. Hence, there should be policies to provide them not only the subsidy for clean fuel but also to build properly ventilated kitchens along with the promotion of clean toilets and water supplies. There is a need to strengthen global efforts, to jointly address the challenges associated with the risks related to WaSH and HAP in order to efficiently reduce the global burden of disease. Further, this will also help to timely attain the sustainable development goals for better health and environment.
Apparatus and method for in-situ cleaning of resist outgassing windows
Klebanoff, Leonard E.; Haney, Steven J.
2001-01-01
An apparatus and method for in-situ cleaning of resist outgassing windows. The apparatus includes a chamber located in a structure, with the chamber having an outgassing window to be cleaned positioned in alignment with a slot in the chamber, whereby radiation energy passes through the window, the chamber, and the slot onto a resist-coated wafer mounted in the structure. The chamber is connected to a gas supply and the structure is connected to a vacuum pump. Within the chamber are two cylindrical sector electrodes and a filament is electrically connected to one sector electrode and a power supply. In a first cleaning method the sector electrodes are maintained at the same voltage, the filament is unheated, the chamber is filled with argon (Ar) gas under pressure, and the window is maintained at a zero voltage, whereby Ar ions are accelerated onto the window surface, sputtering away carbon deposits that build up as a result of resist outgassing. A second cleaning method is similar except oxygen gas (O.sub.2) is admitted to the chamber instead of Ar. These two methods can be carried out during lithographic operation. A third method, carried out during a maintenance period, involves admitting CO.sub.2 into the chamber, heating the filament to a point of thermionic emission, the sector electrodes are at different voltages, excited CO.sub.2 gas molecules are created which impact the carbon contamination on the window, and gasify it, producing CO gaseous products that are pumped away.
Bello, Anila; Quinn, Margaret M; Perry, Melissa J; Milton, Donald K
2009-03-27
In recent years, cleaning has been identified as an occupational risk because of an increased incidence of reported respiratory effects, such as asthma and asthma-like symptoms among cleaning workers. Due to the lack of systematic occupational hygiene analyses and workplace exposure data, it is not clear which cleaning-related exposures induce or aggravate asthma and other respiratory effects. Currently, there is a need for systematic evaluation of cleaning products ingredients and their exposures in the workplace. The objectives of this work were to: a) identify cleaning products' ingredients of concern with respect to respiratory and skin irritation and sensitization; and b) assess the potential for inhalation and dermal exposures to these ingredients during common cleaning tasks. We prioritized ingredients of concern in cleaning products commonly used in several hospitals in Massachusetts. Methods included workplace interviews, reviews of product Materials Safety Data Sheets and the scientific literature on adverse health effects to humans, reviews of physico-chemical properties of cleaning ingredients, and occupational hygiene observational analyses. Furthermore, the potential for exposure in the workplace was assessed by conducting qualitative assessment of airborne exposures and semi-quantitative assessment of dermal exposures. Cleaning products used for common cleaning tasks were mixtures of many chemicals, including respiratory and dermal irritants and sensitizers. Examples of ingredients of concern include quaternary ammonium compounds, 2-butoxyethanol, and ethanolamines. Cleaning workers are at risk of acute and chronic inhalation exposures to volatile organic compounds (VOC) vapors and aerosols generated from product spraying, and dermal exposures mostly through hands. Cleaning products are mixtures of many chemical ingredients that may impact workers' health through air and dermal exposures. Because cleaning exposures are a function of product formulations and product application procedures, a combination of product evaluation with workplace exposure assessment is critical in developing strategies for protecting workers from cleaning hazards. Our task based assessment methods allowed classification of tasks in different exposure categories, a strategy that can be employed by epidemiological investigations related to cleaning. The methods presented here can be used by occupational and environmental health practitioners to identify intervention strategies.
2009-01-01
Background In recent years, cleaning has been identified as an occupational risk because of an increased incidence of reported respiratory effects, such as asthma and asthma-like symptoms among cleaning workers. Due to the lack of systematic occupational hygiene analyses and workplace exposure data, it is not clear which cleaning-related exposures induce or aggravate asthma and other respiratory effects. Currently, there is a need for systematic evaluation of cleaning products ingredients and their exposures in the workplace. The objectives of this work were to: a) identify cleaning products' ingredients of concern with respect to respiratory and skin irritation and sensitization; and b) assess the potential for inhalation and dermal exposures to these ingredients during common cleaning tasks. Methods We prioritized ingredients of concern in cleaning products commonly used in several hospitals in Massachusetts. Methods included workplace interviews, reviews of product Materials Safety Data Sheets and the scientific literature on adverse health effects to humans, reviews of physico-chemical properties of cleaning ingredients, and occupational hygiene observational analyses. Furthermore, the potential for exposure in the workplace was assessed by conducting qualitative assessment of airborne exposures and semi-quantitative assessment of dermal exposures. Results Cleaning products used for common cleaning tasks were mixtures of many chemicals, including respiratory and dermal irritants and sensitizers. Examples of ingredients of concern include quaternary ammonium compounds, 2-butoxyethanol, and ethanolamines. Cleaning workers are at risk of acute and chronic inhalation exposures to volatile organic compounds (VOC) vapors and aerosols generated from product spraying, and dermal exposures mostly through hands. Conclusion Cleaning products are mixtures of many chemical ingredients that may impact workers' health through air and dermal exposures. Because cleaning exposures are a function of product formulations and product application procedures, a combination of product evaluation with workplace exposure assessment is critical in developing strategies for protecting workers from cleaning hazards. Our task based assessment methods allowed classification of tasks in different exposure categories, a strategy that can be employed by epidemiological investigations related to cleaning. The methods presented here can be used by occupational and environmental health practitioners to identify intervention strategies. PMID:19327131
Cookstove Laboratory Research - Fiscal Year 2016 Report ...
This report provides an overview of the work conducted by the EPA cookstove laboratory research team in Fiscal Year 2016. The report describes research and activities including (1) ISO standards development, (2) capacity building for international testing and knowledge centers, (3) laboratory assessments of cookstove systems, (4) journal publications, and (5) cookstove events. The U.S. Environmental Protection Agency’s (EPA’s) cookstove laboratory research program was first developed to assist the EPA-led Partnership for Clean Indoor Air and is now part of the U.S. Government’s commitment to the Global Alliance for Clean Cookstoves (the Alliance). Goals of the program are to: (1) support the development of testing protocols and standards for cookstoves through ISO (International Organization for Standardization) TC (Technical Committee) 285: Clean Cookstoves and Clean Cooking Solutions, (2) support the development of international Regional Testing and Knowledge Centers (many sponsored by the Alliance) for scientifically evaluating and certifying cookstoves to international standards, and (3) provide an independent source of data to Alliance partners. This work supports EPA’s mission to protect human health and the environment. Household air pollution, mainly from solid-fuel cookstoves in the developing world, is estimated to cause approximately 4 million premature deaths per year, and emissions of black carbon and other pollutants from cookstoves aff
NASA Astrophysics Data System (ADS)
Ivanova, Irina; Sushko, Elena; Lyshnikova, Anna; Prykina, Larisa
2018-03-01
Current developments are devoted to the environmental safety of the foundry. There is a significant amount of pollutants, according to dust, which is released in the working area, during the manufacture of metal structures for high buildings. From the point of dust extraction, the most unfavorable areas are shot blasting, sand-blasting chambers and knockout grills. The weight fraction of dust composition with diameters up to 20 μm reaches 43,8% by mass, according to experimental analysis. This kind of dust is the most dangerous to employees and also it creates problems for dust-cleaning in the air.
Zock, Jan-Paul; Vizcaya, David; Le Moual, Nicole
2010-01-01
Purpose of review This paper summarises the recent literature on the relation between cleaning exposures and respiratory health, in particular asthma, including reviews, epidemiological surveys, surveillance programmes and exposure studies. The authors also aimed to identify gaps in the current knowledge and to recommend future research on the topic. Recent findings A large international general population study showed an increased risk of new-onset asthma associated with cleaning work, with professional use of cleaning products, and with domestic use of cleaning sprays. Three surveillance studies confirm the recognition of occupational asthma cases among cleaners and among others who use cleaning products at work. Six workforce-based studies show that respiratory symptoms are partly work-related, and are associated with certain specific exposures including sprays, chlorine bleach and other disinfectants. Summary Recent studies have strengthened the evidence of asthma and other adverse respiratory effects in cleaning workers. Similar effects were seen in other settings where cleaning products are used such as healthcare professionals and homemakers. Both new-onset asthma and work-exacerbated asthma due to cleaning exposures may play a role. Exposure to cleaning sprays, chlorine bleach and other disinfectants may be particularly relevant. The predominant effect mechanisms remain largely unclear and may include both specific sensitisation and irritant-related features. PMID:20093933
NASA Astrophysics Data System (ADS)
Yanlei, Li; Yuling, Liu; Chenwei, Wang; Yue, Li
2016-08-01
The cleaning of copper interconnects after chemical mechanical planarization (CMP) process is a critical step in integrated circuits (ICs) fabrication. Benzotriazole (BTA), which is used as corrosion inhibitor in the copper CMP slurry, is the primary source for the formation of organic contaminants. The presence of BTA can degrade the electrical properties and reliability of ICs which needs to be removed by using an effective cleaning solution. In this paper, an alkaline cleaning solution was proposed. The alkaline cleaning solution studied in this work consists of a chelating agent and a nonionic surfactant. The removal of BTA was characterized by contact angle measurements and potentiodynamic polarization studies. The cleaning properties of the proposed cleaning solution on a 300 mm copper patterned wafer were also quantified, total defect counts after cleaning was studied, scanning electron microscopy (SEM) review was used to identify types of BTA to confirm the ability of cleaning solution for BTA removal. All the results reveal that the chelating agent can effectively remove the BTA residual, nonionic surfactant can further improve the performance. Project supported by the Natural Science Foundation of Hebei Province, China (No. F2015202267) and the Scientific Innovation Grant for Excellent Young Scientists of Hebei University of Technology (No. 2015007).
Electrostatic Hazard Considerations for ODC Solvent Replacement Selection Testing
NASA Technical Reports Server (NTRS)
Fairbourn, Brad
1999-01-01
ODC solvents are used to clean many critical substrates during solid rocket motor production operations. Electrostatic charge generation incidental to these cleaning operations can pose a major safety issue. Therefore, while determining the acceptability of various ODC replacement cleaners, one aspect of the selection criteria included determining the extent of electric charge generation during a typical solvent cleaning operation. A total of six candidate replacement cleaners, sixteen critical substrates, and two types of cleaning swatch materials were studied in simulated cleaning operations. Charge generation and accumulation effects were investigated by measuring the peak voltage and brush discharging effects associated with each cleaning process combination. In some cases, charge generation was found to be very severe. Using the conductivity information for each cleaner, the peak voltage data could in some cases, be qualitatively predicted. Test results indicated that severe charging effects could result in brush discharges that could potentially result in flash fire hazards when occurring in close proximity to flammable vapor/air mixtures. Process controls to effectively mitigate these hazards are discussed.
Chapter 2: Assessing the Potential Energy Impacts of Clean Energy Initiatives
Chapter 2 of Assessing the Multiple Benefits of Clean Energy helps state energy, environmental, and economic policy makers identify and quantify the many benefits of clean energy to support the development and implementation of cost-effective clean energ
NASA Astrophysics Data System (ADS)
AlShaer, A. W.; Li, L.; Mistry, A.
2014-12-01
Laser welding of aluminium alloys typically results in porosity in the fusion zones, leading to poor mechanical and corrosion performances. Mechanical and chemical cleaning of surfaces has been used previously to remove contaminants for weld joint preparations. However, these methods are slow, ineffective (e.g. due to hydrogen trapping) or lead to environmental hazards. This paper reports the effects of short pulsed laser surface cleaning on porosity formation and reduction in laser welding of AC-170PX (AA6014) aluminium sheets (coated with Ti/Zr and lubricated using a dry lubricant AlO70) with two types of joints: fillet edge and flange couch, using an AA4043 filler wire for automotive component assembly. The effect of laser cleaning on porosity reduction during laser welding using a filler wire has not been reported before. In this work, porosity and weld fusion zone geometry were examined prior to and after laser cleaning. The nanosecond pulsed Nd:YAG laser cleaning was found to reduce porosity significantly in the weld fusion zones. For the fillet edge welds, porosity was reduced to less than 0.5% compared with 10-80% without laser cleaning. For flange couch welds, porosity was reduced to 0.23-0.8% with laser cleaning from 0.7% to 4.3% without laser cleaning. This has been found to be due to the elimination of contaminations and oxide layers that contribute to the porosity formation. The laser cleaning is based on thermal ablation. This research focuses on porosity reduction in laser welding of aluminium alloy. Weld quality was investigated for two joints, fillet edge and flange couch joints. The effect of laser cleaning on porosity reduction after welding was investigated. It was found that laser cleaning reduced porosity less than 1% in both joints. Weld dimensions and strength were evaluated and discussed for both types of joints.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mendell, Mark J.; Apte, Mike G.
This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptivemore » ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These strategies, however, would make it more complex and more prescriptive, and would require substantial research. One practical intermediate strategy to save energy would be an alternate VRP, allowing VRs lower than currently prescribed, as long as indoor VOC concentrations were no higher than with VRs prescribed under the current VRP. This kind of hybrid, with source reduction and use of air cleaning optional but permitted, could eventually evolve, as data, materials, and air-cleaning technology allowed gradual lowering of allowable concentrations, into a fully developed IAQP. Ultimately, it seems that VR standards must evolve to resemble the IAQP, especially in California, where buildings must achieve zero net energy use within 20 years.« less
2011-08-01
Specimen 625 -58 Cleaned with 50-ksi Water Jet ....................... 18 Figure 12. SEM Images of Inconel Specimen 626-63 Cleaned with 50-ksi Water...SEM Images of Inconel Specimen 626-22 Cleaned with Wet Glass Bead.......................... 21 Figure 15. SEM Images of Titanium Specimen 625 -02...Figure 18. SEM Images of Titanium Specimen 625 -40 Cleaned with Dry Al2O3 (240 grit) ............... 24 Figure 19. SEM Images of Inconel Specimen
Alfa, M J; Nemes, R; Olson, N; Mulaire, A
2006-08-01
Most reusable biopsy forceps and all of the currently available single-use biopsy forceps do not have a port that allows fluid flow down the inner tubular shaft of the device. Reusable biopsy forceps are widely used and reprocessed in healthcare facilities, and single-use biopsy forceps are reprocessed either in-house (eg, in Canada and Japan) or by third-party reprocessors (eg, in the United States). The objective of this study was to determine the cleaning efficacy of automated narrow-lumen sonic irrigation cleaning, sonication-only cleaning, and manual cleaning for biopsy forceps. A simulated-use study was performed by inoculating the inner channel of single-use biopsy forceps with artificial test soil containing both Enterococcus faecalis and Geobacillus stearothermophilus at concentrations of 10(6) colony-forming units per milliliter. The cleaning methods evaluated were manual cleaning, sonication-only cleaning, and "retroflush" cleaning by an automated narrow-lumen irrigator. Bioburden and organic soil reduction after washing was evaluated. Forceps used in biopsies of patients were also tested to determine the worst-case soiling levels. Only retroflush irrigation cleaning could effectively remove material from within the shaft portion of the biopsy forceps: it achieved an average reduction of more than 95% in levels of protein, hemoglobin, carbohydrate, and endotoxin. However, even this method of cleaning was not totally effective, as only a 2 log10 reduction in bioburden could be achieved, and there were low residual levels of hemoglobin and carbohydrate. The data from this evaluation indicate that manual and sonication-only cleaning methods for biopsy forceps were totally ineffective in removing material from within the biopsy forceps. Even the use of retroflush cleaning was not totally effective. These findings suggest that in-hospital reprocessing of biopsy forceps with currently available equipment and cleaning methods is suboptimal.
Pegasus ICON Spacecraft Mate to Separation System
2018-05-09
A crane is used to move and lower NASA's Ionospheric Connection Explorer (ICON) onto the spacecraft separation system May 9, 2018, in a clean room inside Building 1555 at Vandenberg Air Force Base in California. The explorer will launch on June 15, 2018, from Kwajalein Atoll in the Marshall Islands (June 14 in the continental United States) on Orbital ATK's Pegasus XL rocket, which is attached to the company's L-1011 Stargazer aircraft. ICON will study the frontier of space - the dynamic zone high in Earth's atmosphere where terrestrial weather from below meets space weather above. The explorer will help determine the physics of Earth's space environment and pave the way for mitigating its effects on our technology, communications systems and society.
Becker, Craig M; Lee, Joseph G L; Hudson, Suzanne; Hoover, Jeanne; Civils, Donald
2017-06-01
While clean indoor air legislation at the state level is an evidence-based recommendation, only limited evidence exists regarding the impact of clean indoor air policies on state smoking prevalence. Using state smoking prevalence data from 1997 to 2010, a repeated measures observational analysis assessed the association between clean indoor air policies (i.e., workplace, restaurant, and bar) and state smoking prevalence while controlling for state cigarette taxes and year. The impacts from the number of previous years with any clean indoor air policy, the number of policies in effect during the current year, and the number of policies in effect the previous year were analyzed. Findings indicate a smoking prevalence predicted decrease of 0.13 percentage points (p=0.03) for each additional year one or more clean indoor air policies were in effect, a predicted decrease of 0.12 percentage points (p=0.09) for each policy in effect in the current year, and a predicted decrease of 0.22 percentage points (p=0.01) for each policy in effect in the previous year on the subsequent year. Clean indoor air policies show measurable associations with reductions in smoking prevalence within a year of implementation above and beyond taxes and time trends. Further efforts are needed to diffuse clean indoor air policies across states and provinces that have not yet adopted such policies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.
Evaluating a new paradigm for comparing surface disinfection in clinical practice.
Carling, Philip C; Perkins, Jennifer; Ferguson, JoAnn; Thomasser, Anita
2014-11-01
Despite an increasing understanding of the importance of near-patient surfaces in the transmission of healthcare-associated pathogens, there remains a need to define the relative clinical effectiveness of disinfection interventions. A serial 2-phase evaluation of the clinical effectiveness of 2 surface disinfectants. A general acute care hospital. A unique system for quantifying bioburden reduction while monitoring the possible impact of differences in cleaning thoroughness was used to compare the clinical effectiveness of a traditional quaternary ammonium compound (QAC) and a novel peracetic acid/hydrogen peroxide disinfectant (ND) as part of terminal room cleaning. As a result of QAC cleaning, 93 (40%) of 237 cleaned surfaces confirmed by fluorescent marker (DAZO) removal were found to have complete removal of aerobic bioburden. During the ND phase of the study, bioburden was removed from 211 (77%) of 274 cleaned surfaces. Because there was no difference in the thoroughness of cleaning with either disinfectant (65.3% and 66.4%), the significant ([Formula: see text]) difference in bioburden reduction can be attributed to better cleaning efficacy with the ND. In the context of the study design, the ND was 1.93 times more effective in removing bacterial burden than the QAC ([Formula: see text]). Furthermore, the study design represents a new research paradigm in which 2 interventions can be compared by concomitantly and objectively analyzing both the product and process variables in a manner that can be used to define the relative effectiveness of all disinfection cleaning interventions.
Martin, U; Sonntag, A-K; Neuhaus, B; Karch, H
2004-10-01
The effectiveness of cleaning and disinfection of environmental surfaces was evaluated in three nursing homes using bacteriological monitoring. Samples from inmates (nose, throat and wounds) and surface cleaning equipment were also taken. Cleaning solutions, disinfectants and cleaning clothes were found to be highly contaminated in two of three institutions. Referring to the surfaces in some cases disinfection didn't reduce bacterial colony counts and seeded MRSA as a potential pathogen in one nursing home. Six MRSA-positive inmates and identical strains were registered in the environment. MRSA can be used as a marker organism to demonstrate effectiveness of cleaning. To achieve further improvement bacteriological monitoring can help in focussing special cleaning and disinfection related problems.
NASA Astrophysics Data System (ADS)
Ilie, C. A.; Visa, I.; Duta, A.
2016-08-01
The EU legal frame imposes the Nearly Zero Energy Buildings (nZEB) status to any new public building starting with January 1st, 2019 and for any other new building starting with 2021. Basically, nZEB represents a Low Energy Building (LEB) that covers more than half of the energy demand by using renewable energy systems installed on or close to it. Thus, two steps have to be followed in developing nZEB: (1) reaching the LEB status through state- of-the art architectural and construction solutions (for the new buildings) or through refurbishing for the already existent buildings, followed by (2) implementing renewables; in Romania, over 65% of the energy demand in a building is directly linked to heating, domestic hot water (DHW), and - in certain areas - for cooling. Thus, effort should be directed to reduce the thermal energy demand to be further covered by using clean and affordable systems: solar- thermal systems, heat pumps, biomass, etc. or their hybrid combinations. Obviously this demand is influenced by the onsite climatic profile and by the building performance. An almost worst case scenario is approached in the paper, considering a community implemented in a mountain area, with cold and long winters and mild summers (Odorheiul Secuiesc city, Harghita county, Romania). Three representative types of buildings are analysed: multi-family households (in blocks of flats), single-family houses and administrative buildings. For the first two types, old and refurbished buildings were comparatively discussed.
Bacterial contamination of stethoscope chest pieces and the effect of daily cleaning.
Fujita, H; Hansen, B; Hanel, R
2013-01-01
Stethoscopes are a potential source of nosocomial infection for hospitalized humans, a phenomenon not previously studied in companion animals. To determine if daily cleaning of stethoscope chest pieces reduces bacterial contamination between cleanings. Client-owned dogs and cats. Prospective observational study. In phase 1, bacterial cultures were obtained from the chest pieces of 10 participant stethoscopes once weekly for 3 weeks. In phase 2, stethoscopes were cleaned daily and 2 culture samples were obtained once weekly, immediately before and after cleaning with 70% isopropyl alcohol, for 3 weeks. Daily cleaning eliminated bacteria immediately after each cleaning (P = .004), but did not reduce the rate of positive cultures obtained before cleaning in phase 2. Cultures were positive for 20/30 (67%) samples during phase 1 and 18/30 (60%) obtained before daily cleaning during phase 2. Recovered organisms included normal skin flora, agents of opportunistic infections, and potential pathogens. The only genus that was repeatedly recovered from the same stethoscope for 2 or more consecutive weeks was Bacillus sp. Daily cleaning was highly effective at removing bacteria, but provided no reduction in precleaning contamination. Cleaning stethoscopes after use on dogs or cats infected with pathogenic bacteria and before use on immunocompromised animals should be considered. Copyright © 2013 by the American College of Veterinary Internal Medicine.
Optimum outlier model for potential improvement of environmental cleaning and disinfection.
Rupp, Mark E; Huerta, Tomas; Cavalieri, R J; Lyden, Elizabeth; Van Schooneveld, Trevor; Carling, Philip; Smith, Philip W
2014-06-01
The effectiveness and efficiency of 17 housekeepers in terminal cleaning 292 hospital rooms was evaluated through adenosine triphosphate detection. A subgroup of housekeepers was identified who were significantly more effective and efficient than their coworkers. These optimum outliers may be used in performance improvement to optimize environmental cleaning.
EVALUATION OF TWO CLEANING METHODS FOR THE REMOVAL OF ASBESTOS FIBERS FROM CARPET
This research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. outine carpet cleaning operations using high-efficiency particul...
Sunlight Responsive Thermochromic Window System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Millett, F,A; Byker,H, J
2006-10-27
Pleotint has embarked on a novel approach with our Sunlight Responsive Thermochromic, SRT™, windows. We are integrating dynamic sunlight control, high insulation values and low solar heat gain together in a high performance window. The Pleotint SRT window is dynamic because it reversibly changes light transmission based on thermochromics activated directly by the heating effect of sunlight. We can achieve a window package with low solar heat gain coefficient (SHGC), a low U value and high insulation. At the same time our windows provide good daylighting. Our innovative window design offers architects and building designers the opportunity to choose theirmore » desired energy performance, excellent sound reduction, external pane can be self-cleaning, or a resistance to wind load, blasts, bullets or hurricanes. SRT windows would provide energy savings that are estimated at up to 30% over traditional window systems. Glass fabricators will be able to use existing equipment to make the SRT window while adding value and flexibility to the basic design. Glazing installers will have the ability to fit the windows with traditional methods without wires, power supplies and controllers. SRT windows can be retrofit into existing buildings,« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1997-10-27
This Corrective Action Investigation Plan (CAIP) contains the environmental sample collection objectives and the criteria for conducting site investigation activities at Corrective Action Unit (CAU) Number 423, the Building 03-60 Underground Discharge Point (UDP), which is located in Area 3 at the Tonopah Test Range (TTR). The TTR, part of the Nellis Air Force Range, is approximately 225 kilometers (140 miles) northwest of Las Vegas, Nevada. CAU Number 423 is comprised of only one Corrective Action Site (CAS) which includes the Building 03-60 UDP and an associated discharge line extending from Building 03-60 to a point approximately 73 meters (240more » feet) northwest. The UDP was used between approximately 1965 and 1990 to dispose of waste fluids from the Building 03-60 automotive maintenance shop. It is likely that soils surrounding the UDP have been impacted by oil, grease, cleaning supplies and solvents as well as waste motor oil and other automotive fluids released from the UDP.« less
Mandin, C; Derbez, M; Kirchner, S
2012-07-01
This review provides a global overview of indoor air quality issues in schools, office buildings and recreational settings. It presents the most recent scientific publications and the on-going work conducted in France in the frame of the indoor air quality Observatory. Monitoring campaigns on indoor air quality in schools have been carried out in the recent years in Europe. However, few studies have specifically addressed the role of exposure in these buildings on children's health. Indoor air quality in office buildings has been little studied so far. However, some specificities, such as emissions from electronic devices, frequent cleaning, impossibility to open windows in high-rise buildings, for example, should be examined and their role on the health and comfort studied. Finally, even if the time spent in recreational settings is short, the quality of indoor air should also be considered because of specific pollution. This is the case of indoor swimming pools (exposure to chlorination byproducts) and ice-rinks (exposure to exhaust from machines used to smooth the ice). Copyright © 2012 Elsevier Masson SAS. All rights reserved.
A walk through the planned CS building. M.S. Thesis
NASA Technical Reports Server (NTRS)
Khorramabadi, Delnaz
1991-01-01
Using the architectural plan views of our future computer science building as test objects, we have completed the first stage of a Building walkthrough system. The inputs to our system are AutoCAD files. An AutoCAD converter translates the geometrical information in these files into a format suitable for 3D rendering. Major model errors, such as incorrect polygon intersections and random face orientations, are detected and fixed automatically. Interactive viewing and editing tools are provided to view the results, to modify and clean the model and to change surface attributes. Our display system provides a simple-to-use user interface for interactive exploration of buildings. Using only the mouse buttons, the user can move inside and outside the building and change floors. Several viewing and rendering options are provided, such as restricting the viewing frustum, avoiding wall collisions, and selecting different rendering algorithms. A plan view of the current floor, with the position of the eye point and viewing direction on it, is displayed at all times. The scene illumination can be manipulated, by interactively controlling intensity values for 5 light sources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widdop, M.R.
1996-07-01
The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the domestic uranium procurement program funded by the U.S. Atomic Energy Commission. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial actionmore » contractor. Radiological contamination was identified in Building 6, and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widdop, M.R.
1996-08-01
The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, was also the remedialmore » action contractor. Building 34 was radiologically contaminated and the building was demolished in 1996. The soil area within the footprint of the building was analyzed and found to be not contaminated. The area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual closeout report for each contaminated GJPO building.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widdop, M.R.
1996-07-01
The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial action contractor. The soilmore » beneath Building 39 was radiologically contaminated and the building was demolished in 1992. The soil area within the footprint of the building has been remediated in accordance with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widdop, M.R.
1996-07-01
The U.S. Department of Energy (DOE) Junction Projects Office (GJPO) occupies a 61.7 acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the Grand Junction Projects Office Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, is also the remedial actionmore » contractor. Building 44 was radiologically contaminated and the building was demolished in 1994. The soil area within the footprint of the building was not contaminated; it complies with the identified standards and the area can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Widdop, M.R.
1996-08-01
The U.S. Department of Energy (DOE) Grand Junction Projects Office (GJPO) occupies a 61.7-acre facility along the Gunnison River near Grand Junction, Colorado. This site was contaminated with uranium ore and mill tailings during uranium refining activities of the Manhattan Engineer District and during pilot milling experiments conducted for the U.S. Atomic Energy Commission`s domestic uranium procurement program. The DOE Defense Decontamination and Decommissioning Program established the GJPO Remedial Action Project to clean up and restore the facility lands, improvements, and the underlying aquifer. The site contractor for the facility, Rust Geotech, also is the remedial action contractor. The soilmore » beneath Building 18 was found to be radiologically contaminated; the building was not contaminated. The soil was remediated in accordance with identified standards. Building 18 and the underlying soil can be released for unlimited exposure and unrestricted use. This document was prepared in response to a DOE request for an individual final report for each contaminated GJPO building.« less
Glow discharge cleaning of vacuum switch tubes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hayashi, T.; Toya, H.
1991-10-01
This paper reports that glow discharge cleaning has ben advancing as a means of degassing vacuum chambers constructed for a large accelerator or for nuclear fusion research. To clean the whole surface of parts inside a vacuum switch tube (VST), a new technique is tried which generates glow discharge between the inner electrodes and copper grid surrounding it. Photographic observation reveals that the glow discharge spreads out and cleans the whole surface inside the VST. A breakdown test between the inner electrodes shows the effect of the cleaning with this technique. Higher breakdown voltage between the inner electrodes is attainedmore » by performing this glow discharge cleaning in argon rather than hydrogen gas. The difference of the cleaning effect seems to be attributed to that of the energy transfer from ion species to the absorbed molecules and microprotrusions on the surfaces.« less
Clean energy choices: Tips on buying and using renewable energy at home
DOE Office of Scientific and Technical Information (OSTI.GOV)
NREL
This brochure provides information on how consumers can use renewable energy in and around the home. Information on buying green power; using renewables to generate power; using passive and active solar and geothermal heat pumps to heat, cool and light buildings; and using alternative fuels and vehicles is included. Resources at the end of each chapter help readers find more information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacob, Andria; Cyr, Shirley
In April 2010, the City of Portland received a $20 million award from the U.S. Department of Energy, as part of the Energy Efficiency and Conservation Block Grant program. This award was appropriated under the American Recovery and Reinvestment Act (ARRA), passed by President Obama in 2009. DOE’s program became known as the Better Buildings Neighborhood Program (BBNP). The BBNP grant objectives directed the City of Portland Bureau of Planning and Sustainability (BPS) as the primary grantee to expand the BPS-led pilot program, Clean Energy Works Portland, into Clean Energy Works Oregon (CEWO), with the mission to deliver thousands ofmore » home energy retrofits, create jobs, save energy and reduce carbon dioxide emissions.The Final Technical Report explores the successes and lessons learned from the first 3 years of program implementation.« less
The first aluminum coating of the 3700mm primary mirror of the Devasthal Optical Telescope
NASA Astrophysics Data System (ADS)
Bheemireddy, Krishna Reddy; Gopinathan, Maheswar; Pant, Jayshreekar; Omar, Amitesh; Kumar, Brijesh; Uddin, Wahab; Kumar, Nirmal
2016-07-01
Initially the primary mirror of the 3.6m Devasthal Optical Telescope is uncoated polished zerodur glass supplied by Lytkarino Optical Glass Factory, Russia/Advanced Mechanical and Optical Systems, Belgium. In order to do the aluminium coating on the primary mirror the coating plant including washing unit is installed near the telescope (extension building of telescope) by Hind High Vacuum (HHV) Bangalore, India. Magnetron sputtering technique is used for the coating. Several coating trials are done before the primary mirror coating; samples are tested for reflectivity, uniformity, adhesivity and finally commissioned. The primary mirror is cleaned, coated by ARIES. We present here a brief description of the coating plant installation, Mirror cleaning and coating procedures and the testing results of the samples.
Cleaning Process Development for Metallic Additively Manufactured Parts
NASA Technical Reports Server (NTRS)
Tramel, Terri L.; Welker, Roger; Lowery, Niki; Mitchell, Mark
2014-01-01
Additive Manufacturing of metallic components for aerospace applications offers many advantages over traditional manufacturing techniques. As a new technology, many aspects of its widespread utilization remain open to investigation. Among these are the cleaning processes that can be used for post finishing of parts and measurements to verify effectiveness of the cleaning processes. Many cleaning and drying processes and measurement methods that have been used for parts manufactured using conventional techniques are candidates that may be considered for cleaning and verification of additively manufactured parts. Among these are vapor degreasing, ultrasonic immersion and spray cleaning, followed by hot air drying, vacuum baking and solvent displacement drying. Differences in porosity, density, and surface finish of additively manufactured versus conventionally manufactured parts may introduce new considerations in the selection of cleaning and drying processes or the method used to verify their effectiveness. This presentation will review the relative strengths and weaknesses of different candidate cleaning and drying processes as they may apply to additively manufactured metal parts for aerospace applications. An ultrasonic cleaning technique for exploring the cleanability of parts will be presented along with an example using additively manufactured Inconel 718 test specimens to illustrate its use. The data analysis shows that this ultrasonic cleaning approach results in a well-behaved ultrasonic cleaning/extraction behavior. That is, it does not show signs of accelerated cavitation erosion of the base material, which was later confirmed by neutron imaging. In addition, the analysis indicated that complete cleaning would be achieved by ultrasonic immersion cleaning at approximately 5 minutes, which was verified by subsequent cleaning of additional parts.
Report on the first Quadrennial Technology Review (QTR)
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
2011-09-30
Access to clean, affordable, secure, and reliable energy has been a cornerstone of America’s economic growth. The Nation’s systems that produce, store, transmit, and use energy are falling short of U.S. needs. Maintaining energy security, bolstering U.S. competitiveness, and mitigating the environmental impacts of energy are long-standing challenges. Governments, consumers, and the private sector have worked for decades to address these challenges, yet they remain among the Nation’s most pressing issues. President Obama has articulated broad national energy goals for reducing U.S. dependence on oil, reducing pollution, and investing in research and development (R&D) for clean-energy technologies in the Unitedmore » States to create jobs. These include: Reducing oil imports by one-third by 2025; Supporting the deployment of 1 million electric vehicles on the road by 2015; Making non-residential buildings 20% more energy efficient by 2020; Deriving 80% of America's electricity from clean-energy sources by 2035; and Reducing greenhouse gas emissions by 175 by 2020 and 83% of 2050, from a 2005 baseline.« less
NASA Astrophysics Data System (ADS)
Latief, Yusuf; Berawi, Mohammed Ali; Supriadi, Leni; Bintang Koesalamwardi, Ario; Petroceany, Jade; Herzanita, Ayu
2017-12-01
Indonesia is currently encouraging its physical, social and economy development. Physical development for economic development have to be supported by energy availability. For Indonesia, 90% of electrification ratio is still become an important task that has to be completed by the Government. However, the effort to increase electrification can become an environmental problem if it’s done with BAU scenario. The by-product of electric generation is the GHG, which increasing every year since 2006 from various sectors i.e. industry, housing, commercial, transportation, and energy. Net Zero Energy Building (NZEB) is an energy efficient building which can produce energy independently from clean and renewable sources. The energy that is generated by NZEB can be used for the building itself, and can be exported to the central grid. The integration of NZEB and Smart Grid can solve today’s issue on electrification ratio. Literature study will find benchmarks which can be applied in Indonesia along with possible obstacles in applying this technology.
Guidelines for Building Science Education
DOE Office of Scientific and Technical Information (OSTI.GOV)
Metzger, Cheryn E.; Rashkin, Samuel; Huelman, Pat
The U.S. Department of Energy’s (DOE) residential research and demonstration program, Building America, has triumphed through 20 years of innovation. Partnering with researchers, builders, remodelers, and manufacturers to develop innovative processes like advanced framing and ventilation standards, Building America has proven an energy efficient design can be more cost effective, healthy, and durable than a standard house. As Building America partners continue to achieve their stretch goals, they have found that the barrier to true market transformation for high performance homes is the limited knowledge-base of the professionals working in the building industry. With dozens of professionals taking part inmore » the design and execution of building and selling homes, each person should have basic building science knowledge relevant to their role, and an understanding of how various home components interface with each other. Instead, our industry typically experiences a fragmented approach to home building and design. After obtaining important input from stakeholders at the Building Science Education Kick-Off Meeting, DOE created a building science education strategy addressing education issues preventing the widespread adoption of high performance homes. This strategy targets the next generation and provides valuable guidance for the current workforce. The initiative includes: • Race to Zero Student Design Competition: Engages universities and provides students who will be the next generation of architects, engineers, construction managers and entrepreneurs with the necessary skills and experience they need to begin careers in clean energy and generate creative solutions to real world problems. • Building Science to Sales Translator: Simplifies building science into compelling sales language and tools to sell high performance homes to their customers. • Building Science Education Guidance: Brings together industry and academia to solve problems related to building science education. This report summarizes the steps DOE has taken to develop guidance for building science education and outlines a path forward towards creating real change for an industry in need. The Guidelines for Building Science Education outlined in Appendix A of this report have been developed for external stakeholders to use to certify that their programs are incorporating the most important aspects of building science at the most appropriate proficiency level for their role. The guidelines are intended to be used primarily by training organizations, universities, and certification bodies. Each guideline can be printed or saved as a stand-alone document for ease-of-use by the respective stakeholder group. In 2015, DOE, with leadership from Pacific Northwest National Laboratory (PNNL), is launching a multi-year campaign to promote the adoption of the Guidelines for Building Science Education in a variety of training settings.« less
Healthier Cleaning & Maintenance: Practices and Products for Schools.
ERIC Educational Resources Information Center
New York State Association for Superintendents of School Buildings and Grounds, Albany.
This paper helps all those concerned with keeping schools clean and properly maintained in adopting healthier cleaning and maintenance practices and promoting the purchase and use of environmentally preferable products which perform well and are cost effective. It explains how children are exposed to toxic chemicals in school cleaning and…
Self-Cleaning Surfaces: A Third-Year Undergraduate Research Project
ERIC Educational Resources Information Center
Haines, Ronald S.; Wu, Alex H. F.; Zhang, Hua; Coffey, Jacob; Huddle, Thomas; Lafountaine, Justin S.; Lim, Zhi-Jun; White, Eugene A.; Tuong, Nam T.; Lamb, Robert N.
2009-01-01
Superhydrophobic (non water-wettable) surfaces can possess the ability to self-clean (the so-called "lotus effect"). The task of devising the apparatus and method for quantifying this self-cleaning effect was offered as a project in a third-year undergraduate laboratory course. Using commonly available equipment the students devised a…
Cleaning procedure for improved photothermal background of toroidal optical microresonators
NASA Astrophysics Data System (ADS)
Horak, Erik H.; Knapper, Kassandra A.; Heylman, Kevin D.; Goldsmith, Randall H.
2016-09-01
High Q-factors and small mode volumes have made toroidal optical microresonators exquisite sensors to small shifts in the effective refractive index of the WGM modes. Eliminating contaminants and improving quality factors is key for many different sensing techniques, and is particularly important for photothermal imaging as contaminants add photothermal background obscuring objects of interest. Several different cleaning procedures including wet- and dry-chemical procedures are tested for their effect on Q-factors and photothermal background. RCA cleaning was shown to be successful in contrast to previously described acid cleaning procedures, most likely due to the different surface reactivity of the acid reagents used. UV-ozone cleaning was shown to be vastly superior to O2 plasma cleaning procedures, significantly reducing the photothermal background of the resonator.
Edmunds, L M; Rawlinson, A
1998-10-01
Blood contamination of 16 surfaces in the dental surgery was investigated using the Kastle-Meyer test for haemoglobin, after three types of periodontal procedures had been performed on a total of 30 patients. The effect of cleaning surfaces contaminated by blood was investigated using the same test. Cleaning materials used in the dental surgery were tested to rule out the possibility of false positive outcomes and the sensitivity of the test was determined prior to the study. The results show a marked variation in the degree of contamination and efficacy of cleaning following treatment. Overall, root planing was associated with the most widespread and frequent blood contamination and gingival surgery the least. The surgery work surface, edge of the spittoon, aspirator tube and ultrasonic scaler handpiece into which the ultrasonic insert fits, were the most frequently contaminated surfaces. The work surface, dentist's pen, light switch and handle were cleaned most effectively. The least effectively cleaned surfaces were the water dispenser switch, aspirator tube, bracket table and ultrasonic scaler handpiece. Methods for reducing this potential source of cross-infection are discussed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kominsky, J.R.; Freyberg, R.W.
A study was conducted to evaluate the potential for asbestos fiber reentrainment during cleaning of carpet contaminated with asbestos. Two types of carpet cleaning equipment were evaluated at two carpet contamination levels. Airborne asbestos concentrations were determined before and during carpet cleaning. Overall, airborne asbestos concentrations were two to four times greater during the carpet cleaning activity. The level of asbestos contamination and the type of cleaning method used had no statistically significant effect on the relative increase of airborne asbestos concentrations during carpet cleaning.
Hazardous substances in frequently used professional cleaning products.
Gerster, Fabian Melchior; Vernez, David; Wild, Pascal Pierre; Hopf, Nancy Brenna
2014-01-01
A growing number of studies have identified cleaners as a group at risk for adverse health effects of the skin and the respiratory tract. Chemical substances present in cleaning products could be responsible for these effects. Currently, only limited information is available about irritant and health hazardous chemical substances found in cleaning products. We hypothesized that chemical substances present in cleaning products are known health hazardous substances that might be involved in adverse health effects of the skin and the respiratory tract. We performed a systematic review of cleaning products used in the Swiss cleaning sector. We surveyed Swiss professional cleaning companies (n = 1476) to identify the most used products (n = 105) for inclusion. Safety data sheets (SDSs) were reviewed and hazardous substances present in cleaning products were tabulated with current European and global harmonized system hazard labels. Professional cleaning products are mixtures of substances (arithmetic mean 3.5 +/- 2.8), and more than 132 different chemical substances were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent, phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%) and skin (50%), and hazards by ingestion (60%) were the most reported. Cleaning products potentially give rise to simultaneous exposures to different chemical substances. As professional cleaners represent a large workforce, and cleaning products are widely used, it is a major public health issue to better understand these exposures. The list of substances provided in this study contains important information for future occupational exposure assessment studies.
Hazardous substances in frequently used professional cleaning products
Gerster, Fabian Melchior; Vernez, David; Wild, Pascal Pierre; Hopf, Nancy Brenna
2014-01-01
Background: A growing number of studies have identified cleaners as a group at risk for adverse health effects of the skin and the respiratory tract. Chemical substances present in cleaning products could be responsible for these effects. Currently, only limited information is available about irritant and health hazardous chemical substances found in cleaning products. We hypothesized that chemical substances present in cleaning products are known health hazardous substances that might be involved in adverse health effects of the skin and the respiratory tract. Methods: We performed a systematic review of cleaning products used in the Swiss cleaning sector. We surveyed Swiss professional cleaning companies (n = 1476) to identify the most used products (n = 105) for inclusion. Safety data sheets (SDSs) were reviewed and hazardous substances present in cleaning products were tabulated with current European and global harmonized system hazard labels. Results: Professional cleaning products are mixtures of substances (arithmetic mean 3.5±2.8), and more than 132 different chemical substances were identified in 105 products. The main groups of chemicals were fragrances, glycol ethers, surfactants, solvents; and to a lesser extent, phosphates, salts, detergents, pH-stabilizers, acids, and bases. Up to 75% of products contained irritant (Xi), 64% harmful (Xn) and 28% corrosive (C) labeled substances. Hazards for eyes (59%) and skin (50%), and hazards by ingestion (60%) were the most reported. Conclusions: Cleaning products potentially give rise to simultaneous exposures to different chemical substances. As professional cleaners represent a large workforce, and cleaning products are widely used, it is a major public health issue to better understand these exposures. The list of substances provided in this study contains important information for future occupational exposure assessment studies. PMID:24804339
Bio-Inspired Self-Cleaning Surfaces
NASA Astrophysics Data System (ADS)
Liu, Kesong; Jiang, Lei
2012-08-01
Self-cleaning surfaces have drawn a lot of interest for both fundamental research and practical applications. This review focuses on the recent progress in mechanism, preparation, and application of self-cleaning surfaces. To date, self-cleaning has been demonstrated by the following four conceptual approaches: (a) TiO2-based superhydrophilic self-cleaning, (b) lotus effect self-cleaning (superhydrophobicity with a small sliding angle), (c) gecko setae-inspired self-cleaning, and (d) underwater organisms-inspired antifouling self-cleaning. Although a number of self-cleaning products have been commercialized, the remaining challenges and future outlook of self-cleaning surfaces are also briefly addressed. Through evolution, nature, which has long been a source of inspiration for scientists and engineers, has arrived at what is optimal. We hope this review will stimulate interdisciplinary collaboration among material science, chemistry, biology, physics, nanoscience, engineering, etc., which is essential for the rational design and reproducible construction of bio-inspired multifunctional self-cleaning surfaces in practical applications.
Laser Ablation Cleaning of Self-Reacting Friction Stir Weld Seam Surfaces: A Preliminary Evaluation
NASA Technical Reports Server (NTRS)
Nunes, A. C., Jr.; Russell, C. K.; Brooke, S. A.; Parry, Q.; Lowrey, N. M.
2014-01-01
Anodized aluminum panels were cleaned by three lasers at three separate sites with a view to determining whether more economical laser cleaning might supplant current manual cleaning methods for preparation of surfaces to be welded by the self-reacting friction stir process. Uncleaned panels yielded welds exhibiting residual oxide defect (ROD) and failing at very low stresses along the trace of the weld seam. Manually cleaned panels yielded welds without ROD; these welds failed at nominal stress levels along an angled fracture surface not following the weld seam trace. Laser cleaned panels yielded welds failing at intermediate stress levels. The inadequacy of the laser cleaning processes leaves questions: Was the anodized aluminum test too stringent to represent actual cleaning requirements? Were the wrong laser cleaning techniques/parameters used for the study? Is the laser cleaning mechanism inadequate for effective preweld surface cleaning?
NASA Astrophysics Data System (ADS)
Bixler, Gregory D.; Bhushan, Bharat
2013-08-01
Researchers are continually inspired by living nature to solve complex challenges. For example, unique surface characteristics of rice leaves and butterfly wings combine the shark skin (anisotropic flow leading to low drag) and lotus leaf (superhydrophobic and self-cleaning) effects, producing the so-called rice and butterfly wing effect. In this paper, we present an overview of rice leaf and butterfly wing fluid drag and self-cleaning studies. In addition, we examine two other promising aquatic surfaces in nature known for such properties, including fish scales and shark skin. Morphology, drag, self-cleaning, contact angle, and contact angle hysteresis data are presented to understand the role of wettability, viscosity, and velocity. Liquid repellent coatings are utilized to recreate or combine various effects. Discussion is provided along with conceptual models describing the role of surface structures related to low drag, self-cleaning, and antifouling properties. Modeling provides design guidance when developing novel low drag and self-cleaning surfaces for applications in the medical, marine, and industrial fields.
Indoor Air Quality Assessment of the San Francisco Federal Building
DOE Office of Scientific and Technical Information (OSTI.GOV)
Apte, Michael; Bennett, Deborah H.; Faulkner, David
2008-07-01
An assessment of the indoor air quality (IAQ) of the San Francisco Federal Building (SFFB) was conducted on May 12 and 14, 2009 at the request of the General Services Administration (GSA). The purpose of the assessment was for a general screening of IAQ parameters typically indicative of well functioning building systems. One naturally ventilated space and one mechanically ventilated space were studied. In both zones, the levels of indoor air contaminants, including CO2, CO, particulate matter, volatile organic compounds, and aldehydes, were low, relative to reference exposure levels and air quality standards for comparable office buildings. We found slightlymore » elevated levels of volatile organic compounds (VOCs) including two compounds often found in"green" cleaning products. In addition, we found two industrial solvents at levels higher than typically seen in office buildings, but the levels were not sufficient to be of a health concern. The ventilation rates in the two study spaces were high by any standard. Ventilation rates in the building should be further investigated and adjusted to be in line with the building design. Based on our measurements, we conclude that the IAQ is satisfactory in the zone we tested, but IAQ may need to be re-checked after the ventilation rates have been lowered.« less
Integrated, flexible, and rapid geophysical surveying
NASA Astrophysics Data System (ADS)
Miller, S. F.; McGinnis, L. D.; Thompson, M. D.; Tome, C.
Aberdeen Proving Ground (APG) is currently managing a comprehensive Installation Restoration Program involving more than 360 solid-waste managing units contained within 13 study areas. The Edgewood area and two landfills in the Aberdeen area appear on the National Priority List under the Comprehensive Environmental Response, Compensation, and Liability Act. Therefore, APG has entered into an interagency agreement with the US Environmental Protection Agency to address the listed areas. The West Branch of the Canal Creek area, located within the Edgewood area, is one of the areas that requires a Source Definition Study because there is an ongoing release of volatile organic compounds into the creek. A report prepared in 1989 included a list of 29 potentially contaminated buildings in the Edgewood area. Sixteen of the buildings contain known contaminants, nine buildings contain unknown contaminants, and four of the buildings are potentially clean. The EAI report recommended that a sampling and monitoring program be established to verify contamination levels in and around each building. Thirteen of the potentially contaminated buildings are in the West Branch of the Canal Creek area and are potential sources of volatile organic compounds. Operations have ceased, and the buildings have been abandoned, but processing equipment, sumps, drains, ventilation systems, and underground storage tanks remain. These appurtenances may contain liquid, solid, or vapor contaminants of unknown nature.
Classification of buildings mold threat using electronic nose
NASA Astrophysics Data System (ADS)
Łagód, Grzegorz; Suchorab, Zbigniew; Guz, Łukasz; Sobczuk, Henryk
2017-07-01
Mold is considered to be one of the most important features of Sick Building Syndrome and is an important problem in current building industry. In many cases it is caused by the rising moisture of building envelopes surface and exaggerated humidity of indoor air. Concerning historical buildings it is mostly caused by outdated raising techniques among that is absence of horizontal isolation against moisture and hygroscopic materials applied for construction. Recent buildings also suffer problem of mold risk which is caused in many cases by hermetization leading to improper performance of gravitational ventilation systems that make suitable conditions for mold development. Basing on our research there is proposed a method of buildings mold threat classification using electronic nose, based on a gas sensors array which consists of MOS sensors (metal oxide semiconductor). Used device is frequently applied for air quality assessment in environmental engineering branches. Presented results show the interpretation of e-nose readouts of indoor air sampled in rooms threatened with mold development in comparison with clean reference rooms and synthetic air. Obtained multivariate data were processed, visualized and classified using a PCA (Principal Component Analysis) and ANN (Artificial Neural Network) methods. Described investigation confirmed that electronic nose - gas sensors array supported with data processing enables to classify air samples taken from different rooms affected with mold.
Active cleaning technique for removing contamination from optical surfaces in space
NASA Technical Reports Server (NTRS)
Shannon, R. L.; Gillette, R. B.; Cruz, G. A.
1973-01-01
An active cleaning technique for removing contaminants from optical surfaces in space was investigated with emphasis on the feasibility of using plasma exposure as a means of in-situ cleaning. The major work accomplished includes: (1) development of an in-situ reflectometer for use in conjunction with the contaminant film deposition/cleaning facility; (2) completion of Apollo Telescope Mount (ATM) filter treatment experiments to assess the effects of plasma exposure on the UV transmittance; (3) attempts to correlate the atomic oxygen flux with cleaning rate; (4) completion of in-situ butadien contamination/plasma cleaning/UV reflectance measurement experiments; (5) carbon cleaning experiments using various gases; (6) completion of silicone contamination/cleaning experiments; and (7) experiments conducted at low chamber pressures to determine cleaning rate distribution and contamination of surfaces adjacent to those being cleaned.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hodgson, Alfred T.; Sullivan, Douglas P.; Fisk, William J.
2005-09-30
Efficient removal of indoor generated airborne particles and volatile organic compounds (VOCs) in office buildings and other large buildings may allow for a reduction in outdoor air supply rates with concomitant energy savings while still maintaining acceptable indoor air quality in these buildings. Ultra-Violet Photocatalytic Oxidation (UVPCO) air cleaners have the potential to achieve the necessary reductions in indoor VOC concentrations at relatively low cost. In this study, laboratory experiments were conducted with a scaled, prototype UVPCO device designed for use in a duct system. The experimental UVPCO contained two 30 by 30-cm honeycomb monoliths coated with titanium dioxide andmore » 3% by weight tungsten oxide. The monoliths were irradiated with 12 UVC lamps arranged in four banks. The UVPCO was challenged with four mixtures of VOCs typical of mixtures encountered in indoor air. A synthetic office mixture contained 27 VOCs commonly measured in office buildings. A cleaning product mixture contained three cleaning products with high market shares. A building product mixture was created by combining sources including painted wallboard, composite wood products, carpet systems, and vinyl flooring. A fourth mixture contained formaldehyde and acetaldehyde. Steady-state concentrations were produced in a classroom laboratory or a 20-m{sup 3} environmental chamber. Air was drawn through the UVPCO, and single pass conversion efficiencies were measured from replicate air samples collected upstream and downstream of the reactor section. Concentrations of the mixtures were manipulated, with concentrations of individual VOCs mostly maintained below 10 ppb. Device flow rates were varied between 165 and 580 m{sup 3}/h. Production of formaldehyde, acetaldehyde, acetone, formic acid, and acetic acid as reaction products was investigated. Conversion efficiency data were generated for 48 individual VOCs or groups of closely related compounds. Alcohols and glycol ethers were the most reactive chemical classes with conversion efficiencies often near or above 70% at the low flow rate and near 40% at the high flow rate. Ketones and terpene hydrocarbons were somewhat less reactive. The relative VOC conversion rates are generally favorable for treatment of indoor air since many contemporary products used in buildings employ oxygenated solvents. A commercial UVPCO device likely would be installed in the supply air stream of a building and operated to treat both outdoor and recirculated air. Assuming a recirculation rate comparable to three times the normal outdoor air supply rate, simple mass-balance modeling suggests that a device with similar characteristics to the study unit has sufficient conversion efficiencies for most VOCs to compensate for a 50% reduction in outdoor air supply without substantially impacting indoor VOC concentrations. Formaldehyde, acetaldehyde, acetone, formic acid, and acetic acid were produced in these experiments as reaction byproducts. No other significant byproducts were observed. A coupled steady-state mass balance model is presented and applied to VOC data from a study of a single office building. For the operating assumptions described above, the model estimated a three-fold increase in indoor formaldehyde and acetaldehyde concentrations. The outcome of this limited assessment suggests that evaluation of the potential effects of the operation of a UVPCO device on indoor concentrations of these contaminants is warranted. Other suggested studies include determining VOC conversion efficiencies in actual buildings and evaluating changes in VOC conversion efficiency as monoliths age with long-term operation.« less
Cleaning at Home and at Work in Relation to Lung Function Decline and Airway Obstruction.
Svanes, Øistein; Bertelsen, Randi J; Lygre, Stein H L; Carsin, Anne E; Antó, Josep M; Forsberg, Bertil; García-García, José M; Gullón, José A; Heinrich, Joachim; Holm, Mathias; Kogevinas, Manolis; Urrutia, Isabel; Leynaert, Bénédicte; Moratalla, Jesús M; Le Moual, Nicole; Lytras, Theodore; Norbäck, Dan; Nowak, Dennis; Olivieri, Mario; Pin, Isabelle; Probst-Hensch, Nicole; Schlünssen, Vivi; Sigsgaard, Torben; Skorge, Trude D; Villani, Simona; Jarvis, Debbie; Zock, Jan P; Svanes, Cecilie
2018-05-01
Cleaning tasks may imply exposure to chemical agents with potential harmful effects to the respiratory system, and increased risk of asthma and respiratory symptoms among professional cleaners and in persons cleaning at home has been reported. Long-term consequences of cleaning agents on respiratory health are, however, not well described. This study aimed to investigate long-term effects of occupational cleaning and cleaning at home on lung function decline and airway obstruction. The European Community Respiratory Health Survey (ECRHS) investigated a multicenter population-based cohort at three time points over 20 years. A total of 6,235 participants with at least one lung function measurement from 22 study centers, who in ECRHS II responded to questionnaire modules concerning cleaning activities between ECRHS I and ECRHS II, were included. The data were analyzed with mixed linear models adjusting for potential confounders. As compared with women not engaged in cleaning (ΔFEV 1 = -18.5 ml/yr), FEV 1 declined more rapidly in women responsible for cleaning at home (-22.1; P = 0.01) and occupational cleaners (-22.4; P = 0.03). The same was found for decline in FVC (ΔFVC = -8.8 ml/yr; -13.1, P = 0.02; and -15.9, P = 0.002; respectively). Both cleaning sprays and other cleaning agents were associated with accelerated FEV 1 decline (-22.0, P = 0.04; and -22.9, P = 0.004; respectively). Cleaning was not significantly associated with lung function decline in men or with FEV 1 /FVC decline or airway obstruction. Women cleaning at home or working as occupational cleaners had accelerated decline in lung function, suggesting that exposures related to cleaning activities may constitute a risk to long-term respiratory health.
Transactive Campus Energy Systems: Final Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katipamula, Srinivas; Corbin, Charles D.; Haack, Jereme N.
Transactive energy refers to the combination of economic and control techniques to improve grid reliability and efficiency. The fundamental purpose of transactive energy management is to seamlessly coordinate the operation of large numbers of new intelligent assets—such as distributed solar, energy storage and responsive building loads—to provide the flexibility needed to operate the power grid reliably and at minimum cost, particularly one filled with intermittent renewable generation such as the Pacific Northwest. It addresses the key challenge of providing smooth, stable, and predictable “control” of these assets, despite the fact that most are neither owned nor directly controlled by themore » power grid. The Clean Energy and Transactive Campus (CETC) work described in this report was done as part of a Cooperative Research and Development Agreement (CRADA) between the U.S. Department of Energy’s Pacific Northwest National Laboratory (PNNL) and the Washington State Department of Commerce (Commerce) through the Clean Energy Fund (CEF). The project team consisted of PNNL, the University of Washington (UW) and Washington State University (WSU), to connect the PNNL, UW, and WSU campuses to form a multi-campus testbed for transaction-based energy management—transactive—solutions. Building on the foundational transactive system established by the Pacific Northwest Smart Grid Demonstration (PNWSGD), the purpose of the project was to construct the testbed as both a regional flexibility resource and as a platform for research and development (R&D) on buildings/grid integration and information-based energy efficiency. This report provides a summary of the various tasks performed under the CRADA.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
PRIGNANO, A.L.
2003-06-25
This closure plan describes the planned activities and performance standards for closing the Plutonium Finishing Plant (PFP) glovebox HA-20MB that housed an interim status ''Resource Conservation and Recovery Act'' (RCRA) of 1976 treatment unit. This closure plan is certified and submitted to Ecology for incorporation into the Hanford Facility RCRA Permit (HF RCRA Permit) in accordance with Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement; TPA) Milestone M-83-30 requiring submittal of a certified closure plan for ''glovebox HA-20MB'' by July 31, 2003. Glovebox HA-20MB is located within the 231-5Z Building in the 200 West Area of the Hanford Facility.more » Currently glovebox HA-20MB is being used for non-RCRA analytical purposes. The schedule of closure activities under this plan supports completion of TPA Milestone M-83-44 to deactivate and prepare for dismantlement the above grade portions of the 234-5Z and ZA, 243-Z, and 291-Z and 291-Z-1 stack buildings by September 30, 2015. Under this closure plan, glovebox HA-20MB will undergo clean closure to the performance standards of Washington Administrative Code (WAC) 173-303-610 with respect to all dangerous waste contamination from glovebox HA-20MB RCRA operations. Because the intention is to clean close the PFP treatment unit, postclosure activities are not applicable to this closure plan. To clean close the unit, it will be demonstrated that dangerous waste has not been left at levels above the closure performance standard for removal and decontamination. If it is determined that clean closure is not possible or is environmentally impractical, the closure plan will be modified to address required postclosure activities. Because dangerous waste does not include source, special nuclear, and by-product material components of mixed waste, radionuclides are not within the scope of this documentation. Any information on radionuclides is provided only for general knowledge. Clearance form only sent to RHA.« less
Method and apparatus for duct sealing using a clog-resistant insertable injector
Wang, Duo; Modera, Mark P.
2007-01-02
A clog-resistant injector spray nozzle allows relatively unobtrusive insertion through a small access aperture into existing ductwork in occupied buildings for atomized particulate sealing of a ductwork. The spray nozzle comprises an easily cleaned and easily replaced straight liquid tube whose liquid contents are principally propelled by a heated propellant gas, such as heated air. Heat transfer is minimized from the heated propellant gas to the liquid tube until they both exit the injector, thereby greatly reducing the likelihood of nozzle clogging. A method of duct sealing using particles driven by heated propellant gas is described, whereby duct-sealing operations become both faster, and commercially practicable in inhabited commercial and residential buildings.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Regnier, Cindy; Harding, Ari; Robinson, Alastair
The University of Hawai’i at Mānoa (UHM) partnered with the US Department of Energy (DOE) and the Hawai`i Clean Energy Initiative to develop and implement solutions to retrofit exiting buildings to reduce energy consumption by at least 30% as part of DOE’s Commercial Building Partnerships (CBP) Program1. Kuykendall Hall, located on the UHM campus in Honolulu, was the focus of a CBP analysis and design collaboration among the University of Hawai’i, their consultants, and Lawrence Berkeley National Laboratory (LBNL). Kuykendall Hall consists of two 1960s-era wings – a four-story wing containing classrooms, and a seven-story tower containing offices – withmore » a total floor area of approximately 76,000 square feet (ft²).« less
Effect of cleaning status on accuracy and precision of oxygen flowmeters of various ages.
Fissekis, Stephanie; Hodgson, David S; Bello, Nora M
2017-07-01
To evaluate oxygen flowmeters for accuracy and precision, assess the effects of cleaning and assess conformity to the American Society for Testing Materials (ASTM) standards. Experimental study. The flow of oxygen flowmeters from 31 anesthesia machines aged 1-45 years was measured before and after cleaning using a volumetric flow analyzer set at 0.5, 1.0, 2.0, 3.0, and 4.0 L minute -1 . A general linear mixed models approach was used to assess flow accuracy and precision. Flowmeters 1 year of age delivered accurate mean oxygen flows at all settings regardless of cleaning status. Flowmeters ≥5 years of age underdelivered at flows of 3.0 and 4.0 L minute -1 . Flowmeters ≥12 years underdelivered at flows of 2.0, 3.0 and 4.0 L minute -1 prior to cleaning. There was no evidence of any beneficial effect of cleaning on accuracy of flowmeters 5-12 years of age (p > 0.22), but the accuracy of flowmeters ≥15 years of age was improved by cleaning (p < 0.05). Regardless of age, cleaning increased precision, decreasing flow variability by approximately 17%. Nine of 31 uncleaned flowmeters did not meet ASTM standards. After cleaning, a different set of nine flowmeters did not meet standards, including three that had met standards prior to cleaning. Older flowmeters were more likely to underdeliver oxygen, especially at higher flows. Regardless of age, cleaning decreased flow variability, improving precision. However, flowmeters still may fail to meet ASTM standards, regardless of cleaning status. Cleaning anesthesia machine oxygen flowmeters improved precision for all tested machines and partially corrected inaccuracies in flowmeters ≥15 years old. A notable proportion of flowmeters did not meet ASTM standards. Cleaning did not ensure that they subsequently conformed to ASTM standards. We recommend annual flow output validation to identify whether flowmeters are acceptable for continued clinical use. Copyright © 2017 Association of Veterinary Anaesthetists and American College of Veterinary Anesthesia and Analgesia. Published by Elsevier Ltd. All rights reserved.
40 CFR 35.168 - Award limitations.
Code of Federal Regulations, 2013 CFR
2013-07-01
...-assumed enforcement as defined in section 309(a)(2) of the Clean Water Act in effect with respect to the... appropriate, with activities proposed for funding under sections 205(g) and (j) of the Clean Water Act; and (5...-assumed enforcement as defined in section 309(a)(2) of the Clean Water Act in effect with respect to the...
Highly Flexible Superhydrophobic and Fire-Resistant Layered Inorganic Paper.
Chen, Fei-Fei; Zhu, Ying-Jie; Xiong, Zhi-Chao; Sun, Tuan-Wei; Shen, Yue-Qin
2016-12-21
Traditional paper made from plant cellulose fibers is easily destroyed by either liquid or fire. In addition, the paper making industry consumes a large amount of natural trees and thus causes serious environmental problems including excessive deforestation and pollution. In consideration of the intrinsic flammability of organics and minimizing the effects on the environment and creatures, biocompatible ultralong hydroxyapatite nanowires are an ideal building material for inorganic fire-resistant paper. Herein, a new kind of free-standing, highly flexible, superhydrophobic, and fire-resistant layered inorganic paper has been successfully prepared using ultralong hydroxyapatite nanowires as building blocks after the surface modification with sodium oleate. During the vacuum filtration, ultralong hydroxyapatite nanowires assemble into self-roughened setalike microfibers, avoiding the tedious fabrication process to construct the hierarchical structure; the self-roughened microfibers further form the inorganic paper with a nacrelike layered structure. We have demonstrated that the layered structure can significantly improve the resistance to mechanical destruction of the as-prepared superhydrophobic paper. The as-prepared superhydrophobic and fire-resistant inorganic paper shows excellent nonflammability, liquid repellency to various commercial drinks, high thermal stability, and self-cleaning property. Moreover, we have explored the potential applications of the superhydrophobic and fire-resistant inorganic paper as a highly effective adsorbent for oil/water separation, fire-shielding protector, and writing paper.
Assessing the Multiple Benefits of Clean Energy Full Report
Guidance for state energy, environmental, and economic policy makers to identify and quantify the many benefits of clean energy to support the development and implementation of cost-effective clean energy initiatives.
IDEA Clean Energy Application Center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thornton, Robert P.
The DOE Clean Energy Application Centers were launched with a goal of focusing on important aspects of our nation’s energy supply including Efficiency, Reliability and Resiliency. Clean Energy solutions based on Combined Heat & Power (CHP), District Energy and Waste Heat Recovery are at the core of ensuring a reliable and efficient energy infrastructure for campuses, communities, and industry and public enterprises across the country. IDEA members which include colleges and universities, hospitals, airports, downtown utilities as well as manufacturers, suppliers and service providers have long-standing expertise in the planning, design, construction and operations of Clean Energy systems. They representmore » an established base of successful projects and systems at scale and serve important and critical energy loads. They also offer experience, lessons learned and best practices which are of immense value to the sustained growth of the Clean Energy sector. IDEA has been able to leverage the funds from the project award to raise the visibility, improve the understanding and increase deployment CHP, District Energy and Waste Heat Recovery solutions across the regions of our nation, in collaboration with the regional CEAC’s. On August 30, 2012, President Obama signed an Executive Order to accelerate investments in industrial energy efficiency (EE), including CHP and set a national goal of 40 GW of new CHP installation over the next decade IDEA is pleased to have been able to support this Executive Order in a variety of ways including raising awareness of the goal through educational workshops and Conferences and recognizing the installation of large scale CHP and district energy systems. A supporting key area of collaboration has involved IDEA providing technical assistance on District Energy/CHP project screenings and feasibility to the CEAC’s for multi building, multi-use projects. The award was instrumental in the development of a first-order screening/feasibility tool for these types of community energy projects. The Excel based tool incorporates hourly climate based building loads data to arrive at the composite energy demand for the district and compares the Net Present Value (NPV) of the costs of CHP/DE alternatives. This tool has been used to provide assistance to several projects in the Northeast, Mid-Atlantic, Intermountain and Pacific Regions. The tool was disseminated to the CEACs and supplemented by a Training Webinar and a How to Guide IDEA produced a US Community Energy Development Guide to support mayors, planners, community leaders, real estate developers and economic development officials who are interested in planning more sustainable urban energy infrastructure, creating community energy master plans and implementing CHP/ District Energy systems in cities, communities and towns. IDEA has collected industry data and provided a comprehensive data set containing information on District Energy installations in the US. District energy systems are present in 49 states and theDistrict of Columbia. Of the 597 systems 55% were DE alone while the remainder was some combination of CHP, district heating, and district cooling. District energy systems that do not currently involve electric generation are strong near-term candidates for the adoption of CHP due to the magnitude of their aggregated thermal load. This data has helped inform specific and targeted initiatives including technical assistance provided by the CEAC’s for EPA’s Boiler MACT Compliance by large District Heating System boilers. These outcomes have been greatly enabled by the close coordination and collaboration with DOE CEAC leadership and with the eight regional US DOE Clean Energy Application Centers and the award’s incremental funding has allowed IDEA to leverage our resources to be an effective champion for Clean Energy.« less
NASA Helps Build Colorado Economy
2010-12-13
NASA Deputy Administrator Lori Garver delivers remarks at the Colorado State Capitol in Denver on Monday, Dec. 13, 2010, prior to signing an agreement that creates a Technology Acceleration Program and Regional Innovation Cluster for Aerospace and Clean Energy. A manufacturing park focused on rapid new product development and production will be developed to assist growing Colorado businesses while promoting the commercialization of technology developed for the space program. Photo Credit: (NASA/Bill Ingalls)
Proceeding of the 1999 Particle Accelerator Conference. Volume 2
1999-04-02
anill repron the enorag cat manufacturing costs for such devices are significant and a pefnces acd after vari ouroeing steps drastic reduction in...cleanroom contractors, to find one that could meet our needs. Clean Air Technology 4 THEORY OF OPERATION ( CAT ) was able to provide a modular cleanroom...that would accommodate our unusual building geometry. CAT The facility improvements were designed to be used in provided the cleanroom, a local
Design and Implementation of Geothermal Energy Systems at West Chester University
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, James
West Chester University has launched a comprehensive transformation of its campus heating and cooling systems from traditional fossil fuels to geothermal. This change will significantly decrease the institution's carbon footprint and serve as a national model for green campus efforts. The institution has designed a phased series of projects to build a district geo-exchange system with shared well fields, central pumping station and distribution piping to provide the geo-exchange water to campus buildings as their internal building HVAC systems are changed to be able to use the geo-exchange water. This project addresses the US Department of Energy Office of Energymore » Efficiency and Renewable Energy (EERE) goal to invest in clean energy technologies that strengthen the economy, protect the environment, and reduce dependence on foreign oil. In addition, this project advances EERE's efforts to establish geothermal energy as an economically competitive contributor to the US energy supply.« less
Transactive Control of Commercial Building HVAC Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Corbin, Charles D.; Makhmalbaf, Atefe; Huang, Sen
This document details the development and testing of market-based transactive controls for building heating, ventilating and air conditioning (HVAC) systems. These controls are intended to serve the purposes of reducing electricity use through conservation, reducing peak building electric demand, and providing demand flexibility to assist with power system operations. This report is the summary of the first year of work conducted under Phase 1 of the Clean Energy and Transactive Campus Project. The methods and techniques described here were first investigated in simulation, and then subsequently deployed to a physical testbed on the Pacific Northwest National Laboratory (PNNL) campus formore » validation. In this report, we describe the models and control algorithms we have developed, testing of the control algorithms in simulation, and deployment to a physical testbed. Results from physical experiments support previous simulation findings, and provide insights for further improvement.« less
Yang, Jin-Young; Lee, Eun-Sook; Kim, Se-Chul; Cha, So-Yang; Kim, Sung-Tek; Lee, Man-Ho; Han, Sun-Hee; Park, Young-Sang
2013-01-01
From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing systems of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable viruses, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts. PMID:24039290
Cho, Eun-Joo; Yang, Jin-Young; Lee, Eun-Sook; Kim, Se-Chul; Cha, So-Yang; Kim, Sung-Tek; Lee, Man-Ho; Han, Sun-Hee; Park, Young-Sang
2013-08-01
From May to June 2012, a waterborne outbreak of 124 cases of cryptosporidiosis occurred in the plumbing systems of an older high-rise apartment complex in Seoul, Republic of Korea. The residents of this apartment complex had symptoms of watery diarrhea and vomiting. Tap water samples in the apartment complex and its adjacent buildings were collected and tested for 57 parameters under the Korean Drinking Water Standards and for additional 11 microbiological parameters. The microbiological parameters included total colony counts, Clostridium perfringens, Enterococcus, fecal streptococcus, Salmonella, Shigella, Pseudomonas aeruginosa, Cryptosporidium oocysts, Giardia cysts, total culturable viruses, and Norovirus. While the tap water samples of the adjacent buildings complied with the Korean Drinking Water Standards for all parameters, fecal bacteria and Cryptosporidium oocysts were detected in the tap water samples of the outbreak apartment complex. It turned out that the agent of the disease was Cryptosporidium parvum. The drinking water was polluted with sewage from a septic tank in the apartment complex. To remove C. parvum oocysts, we conducted physical processes of cleaning the water storage tanks, flushing the indoor pipes, and replacing old pipes with new ones. Finally we restored the clean drinking water to the apartment complex after identification of no oocysts.
Vyszenski-Moher, Diann L; Arlian, Larry G
2003-07-01
In a controlled laboratory study, disodium octaborate tetrahydrate (DOT) applied to carpets with a carpet-cleaning machine at a rate of 509 ml DOT/8.15 liter H2O/100 m2 (two cups DOT/2 gal H2O/100 feet2) reduced survival and population growth of live Dermatophagoides farinae and Dermatophagoides pteronyssinus by > or = 98% compared with water-cleaned and uncleaned carpets at 8 wk postcleaning. Cleaning with DOT was more effective against D. pteronyssinus than D. farinae.
Uncovering glacier dynamics beneath a debris mantle
NASA Astrophysics Data System (ADS)
Lefeuvre, P.-M.; Ng, F. S. L.
2012-04-01
Debris-covered glaciers (DCGs) have an extensive sediment mantle whose low albedo influences their surface energy balance to cause a buffering effect that could enhance or reduce ablation rates depending on the sediment thickness. The last effect suggests that some DCGs may be less sensitive to climate change and survive for longer than debris-free (or 'clean') glaciers under sustained climatic warming. However, the origin of DCGs is debated and the precise impact of the debris mantle on their flow dynamics and surface geometry has not been quantified. Here we investigate these issues with a numerical model that encapsulates ice-flow physics and surface debris evolution and transport along a glacier flow-line, as well as couples these with glacier mass balance. We model the impact of surface debris on ablation rates by a mathematical function based on published empirical data (including Ostrem's curve). A key interest is potential positive feedback of ablation on debris thickening and lowering of surface albedo. Model simulations show that when DCGs evolve to attain steady-state profiles, they reach lower elevations than clean glaciers do for the same initial and climatic conditions. Their mass-balance profile at steady state displays an inversion near the snout (where the debris cover is thickest) that is not observed in the clean-glacier simulations. In these cases, where the mantle causes complete buffering to inhibit ablation, the DCG does not reach a steady-state profile, and the sediment thickness evolves to a steady value that depends sensitively on the glacier surface velocities. Variation in the assumed englacial debris concentration in our simulations also determines glacier behaviour. With low englacial debris concentration, the DCG retreats initially while its mass-balance gradient steepens, but the glacier re-advances if it subsequently builds up a thick enough debris cover to cause complete buffering. We identify possible ways and challenges of testing this model with field observations of DCGs, given the inherent difficulty that such glaciers may not be in steady state.
Precision cleaning apparatus and method
Schneider, T.W.; Frye, G.C.; Martin, S.J.
1998-01-13
A precision cleaning apparatus and method are disclosed. The precision cleaning apparatus includes a cleaning monitor further comprising an acoustic wave cleaning sensor such as a quartz crystal microbalance (QCM), a flexural plate wave (FPW) sensor, a shear horizontal acoustic plate mode (SH--APM) sensor, or a shear horizontal surface acoustic wave (SH--SAW) sensor; and measurement means connectable to the sensor for measuring in-situ one or more electrical response characteristics that vary in response to removal of one or more contaminants from the sensor and a workpiece located adjacent to the sensor during cleaning. Methods are disclosed for precision cleaning of one or more contaminants from a surface of the workpiece by means of the cleaning monitor that determines a state of cleanliness and any residual contamination that may be present after cleaning; and also for determining an effectiveness of a cleaning medium for removing one or more contaminants from a workpiece. 11 figs.
Precision cleaning apparatus and method
Schneider, Thomas W.; Frye, Gregory C.; Martin, Stephen J.
1998-01-01
A precision cleaning apparatus and method. The precision cleaning apparatus includes a cleaning monitor further comprising an acoustic wave cleaning sensor such as a quartz crystal microbalance (QCM), a flexural plate wave (FPW) sensor, a shear horizontal acoustic plate mode (SH--APM) sensor, or a shear horizontal surface acoustic wave (SH--SAW) sensor; and measurement means connectable to the sensor for measuring in-situ one or more electrical response characteristics that vary in response to removal of one or more contaminants from the sensor and a workpiece located adjacent to the sensor during cleaning. Methods are disclosed for precision cleaning of one or more contaminants from a surface of the workpiece by means of the cleaning monitor that determines a state of cleanliness and any residual contamination that may be present after cleaning; and also for determining an effectiveness of a cleaning medium for removing one or more contaminants from a workpiece.