Mercury Capsule Separation Tests
1960-04-01
Mercury capsule separation from Redstone booster in the Altitude Wind Tunnel (AWT): NASA Lewis conducted full-scale separation tests of the posigrade rockets that were fired after the Redstone rockets burned out. The researchers studied the effect of the posigrade rockets firing on the Redstone booster and retrograde package. This film shows the Mercury capsule being mounted to the Redstone missile model in the Altitude Wind Tunnel. The capsule's engines are fired and it horizontally separates from the Atlas. After firing the capsule swings from an overhead crane.
Kurunmäki, H; Toivonen, J; Lähteenmäki, P; Luukkainen, T
1985-03-01
One Silastic capsule of 15 mm, 20 mm or 30 mm length was inserted subcutaneously into the ventral aspect of the left forearm or upper arm of 28 healthy women during menstrual bleeding or not later than on the seventh day of the menstrual cycle. A new capsule of the same length was inserted after six months and both capsules were removed twelve months after the first insertion. Side-effects, including changes in body weight, blood pressure, menstrual bleeding and liver function test results, were registered. Blood samples were taken from selected subjects twice a week during the 1st, 2nd, 3rd, 6th, 7th and 12th month of use. Plasma concentrations of ST-1435 were measured by radioimmunoassay and the effects of treatment on pituitary and ovarian function were determined by assaying plasma concentrations of LH, FSH, estradiol and progesterone. There were no differences in hormonal side-effects between subjects who had a 30 mm capsule or subjects who had 20 mm or 15 mm capsules, but subjects who had 20 or 15 mm capsules had significantly longer bleeding or spotting periods in comparison with subjects who had a 30 mm capsule. There were no changes in blood pressure, body weight or liver function test results in comparison with pre-insertion values. The plasma level of ST-1435 was not significantly higher during the use of 30 mm capsules than during the use of 20 or 15 mm capsules. During the use of the shorter ST-1435 capsules, plasma estradiol elevation and slightly suppressed FSH were seen, while the use of longer capsules resulted in a slight suppression of LH. Progesterone concentrations during monitored cycles indicated anovulation. No pregnancies occurred during the study period of one year. The continuation rate at one year was 71% in the 30 mm capsule group and 57% in the 20 and 15 mm capsule groups taken together.
Lien, Gi-Shih; Liu, Chih-Wen; Jiang, Joe-Air; Chuang, Cheng-Long; Teng, Ming-Tsung
2012-07-01
This paper presents a novel solution of a hand-held external controller to a miniaturized capsule endoscope in the gastrointestinal (GI) tract. Traditional capsule endoscopes move passively by peristaltic wave generated in the GI tract and the gravity, which makes it impossible for endoscopists to manipulate the capsule endoscope to the diagnostic disease areas. In this study, the main objective is to present an endoscopic capsule and a magnetic field navigator (MFN) that allows endoscopists to remotely control the locomotion and viewing angle of an endoscopic capsule. The attractive merits of this study are that the maneuvering of the endoscopic capsule can be achieved by the external MFN with effectiveness, low cost, and operation safety, both from a theoretical and an experimental point of view. In order to study the magnetic interactions between the endoscopic capsule and the external MFN, a magnetic-analysis model is established for computer-based finite-element simulations. In addition, experiments are conducted to show the control effectiveness of the MFN to the endoscopic capsule. Finally, several prototype endoscopic capsules and a prototype MFN are fabricated, and their actual capabilities are experimentally assessed via in vitro and ex vivo tests using a stomach model and a resected porcine stomach, respectively. Both in vitro and ex vivo test results demonstrate great potential and practicability of achieving high-precision rotation and controllable movement of the capsule using the developed MFN.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul Demkowicz; Lance Cole; Scott Ploger
The AGR-1 irradiation experiment ended on November 6, 2009, after 620 effective full power days in the Advanced Test Reactor, achieving a peak burnup of 19.6% FIMA. The test train was shipped to the Materials and Fuels Complex in March 2010 for post-irradiation examination. The first PIE activities included non-destructive examination of the test train, followed by disassembly of the test train and individual capsules and detailed inspection of the capsule contents, including the fuel compacts and the graphite fuel holders. Dimensional measurements of the compacts, graphite holders, and steel capsules shells were performed using a custom vision measurement systemmore » (for outer diameters and lengths) and conventional bore gauges (for inner diameters). Gamma spectrometry of the intact test train gave a preliminary look at the condition of the interior components. No evidence of damage to compacts or graphite components was evident from the isotopic and gross gamma scans. Neutron radiography of the intact Capsule 2 showed a high degree of detail of interior components and confirmed the observation that there was no major damage to the capsule. Disassembly of the capsules was initiated using procedures qualified during out-of-cell mockup testing. Difficulties were encountered during capsule disassembly due to irradiation-induced changes in some of the capsule components’ properties, including embrittled niobium and molybdenum parts that were susceptible to fracture and swelling of the graphite fuel holders that affected their removal from the capsule shells. This required various improvised modifications to the disassembly procedure to avoid damage to the fuel compacts. Ultimately the capsule disassembly was successful and only one compact from Capsule 4 (out of 72 total in the test train) sustained damage during the disassembly process, along with the associated graphite holder. The compacts were generally in very good condition upon removal. Only relatively minor damage or markings were visible using high resolution photographic inspection. Compact dimensional measurements indicated diametrical shrinkage of 0.9 to 1. 4%, and length shrinkage of 0.2 to 1.1%. The shrinkage was somewhat dependent on compact location within each capsule and within the test train. Compacts exhibited a maximum diametrical shrinkage at a fast neutron fluence of approximately 3×1021 n/cm2. A multivariate statistical analysis indicates that fast neutron fluence as well as compact position in the test train influence compact shrinkage.« less
AGR-2 Irradiated Test Train Preliminary Inspection and Disassembly First Look
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ploger, Scott; Demkowciz, Paul; Harp, Jason
2015-05-01
The AGR 2 irradiation experiment began in June 2010 and was completed in October 2013. The test train was shipped to the Materials and Fuels Complex in July 2014 for post-irradiation examination (PIE). The first PIE activities included nondestructive examination of the test train, followed by disassembly of the test train and individual capsules and detailed inspection of the capsule contents, including the fuel compacts and their graphite fuel holders. Dimensional metrology was then performed on the compacts, graphite holders, and steel capsule shells. AGR 2 disassembly and metrology were performed with the same equipment used successfully on AGR 1more » test train components. Gamma spectrometry of the intact test train gave a preliminary look at the condition of the interior components. No evidence of damage to compacts or graphite components was evident from the isotopic and gross gamma scans. Disassembly of the AGR 2 test train and its capsules was conducted rapidly and efficiently by employing techniques refined during the AGR 1 disassembly campaign. Only one major difficulty was encountered while separating the test train into capsules when thermocouples (of larger diameter than used in AGR 1) and gas lines jammed inside the through tubes of the upper capsules, which required new tooling for extraction. Disassembly of individual capsules was straightforward with only a few minor complications. On the whole, AGR 2 capsule structural components appeared less embrittled than their AGR 1 counterparts. Compacts from AGR 2 Capsules 2, 3, 5, and 6 were in very good condition upon removal. Only relatively minor damage or markings were visible using high resolution photographic inspection. Compact dimensional measurements indicated radial shrinkage between 0.8 to 1.7%, with the greatest shrinkage observed on Capsule 2 compacts that were irradiated at higher temperature. Length shrinkage ranged from 0.1 to 0.9%, with by far the lowest axial shrinkage on Capsule 3 compacts—possibly as a consequence of lower packing fraction or larger particle size. Differences in fast neutron fluence among compacts from these four capsules had no obvious effect on radial and axial shrinkage. (The AGR 2 experiment included Capsule 1 containing French compacts and Capsule 4 with compacts made at Oak Ridge National Laboratory using South African fuel particles. Information on these two batches of AGR 2 fuel compacts is confined to restricted Appendices A and B because of proprietary information limitations.)« less
Reentry Motion and Aerodynamics of the MUSES-C Sample Return Capsule
NASA Astrophysics Data System (ADS)
Ishii, Nobuaki; Yamada, Tetsuya; Hiraki, Koju; Inatani, Yoshifumi
The Hayabusa spacecraft (MUSES-C) carries a small capsule for bringing asteroid samples back to the earth. The initial spin rate of the reentry capsule together with the flight path angle of the reentry trajectory is a key parameter for the aerodynamic motion during the reentry flight. The initial spin rate is given by the spin-release mechanism attached between the capsule and the mother spacecraft, and the flight path angle can be modified by adjusting the earth approach orbit. To determine the desired values of both parameters, the attitude motion during atmospheric flight must be clarified, and angles of attack at the maximum dynamic pressure and the parachute deployment must be assessed. In previous studies, to characterize the aerodynamic effects of the reentry capsule, several wind-tunnel tests were conducted using the ISAS high-speed flow test facilities. In addition to the ground test data, the aerodynamic properties in hypersonic flows were analyzed numerically. Moreover, these data were made more accurate using the results of balloon drop tests. This paper summarized the aerodynamic properties of the reentry capsule and simulates the attitude motion of the full-configuration capsule during atmospheric flight in three dimensions with six degrees of freedom. The results show the best conditions for the initial spin rates and flight path angles of the reentry trajectory.
Brochu, Alice B.W.; Matthys, Oriane B.; Craig, Stephen L.; Reichert, William M.
2014-01-01
The tissue adhesive 2-octyl cyanoacrylate (OCA) was encapsulated in polyurethane microshells and incorporated into bone cement to form a catalyst free, self-healing bone cement comprised of all clinically approved components. The bending strength, modulus, and fatigue lifetime were investigated in accordance with ASTM and ISO standards for the testing of PMMA bone cement. The bending strength of bone cement specimens decreased with increasing wt% capsules content for capsules without or with OCA, with specimens of < 5 wt% capsule content showing minimal effect. In contrast, bone cement bending modulus was insensitive to capsule content. Load controlled fatigue testing was performed in air at room temperature on capsule free bone cement (0 wt%), bone cement with 5 wt% OCA-free capsules (5 wt% No OCA), and 5 wt% OCA-containing capsules (5 wt% OCA). Specimens were tested at a frequency of 5 Hz at maximum stresses of 90%, 80%, 70% and 50% of each specimen's bending strength until failure. The 5 wt% OCA exhibited significant self-healing at 70% and 50% of its reference strength (p < 0.05). Fatigue testing of all three specimen types in air at 22 MPa (50% of reference strength of the 5 wt% OCA specimens) showed that the cycles to failure of OCA-containing specimens was increased by two-fold compared to the OCA-free and capsule-free specimens. This study represents the first demonstration of dynamic, catalyst-free self-healing in a biomaterial formulation. PMID:24825796
Wang, Y T; Mohammed, S D; Farmer, A D; Wang, D; Zarate, N; Hobson, A R; Hellström, P M; Semler, J R; Kuo, B; Rao, S S; Hasler, W L; Camilleri, M; Scott, S M
2015-09-01
The wireless motility capsule (WMC) offers the ability to investigate luminal gastrointestinal (GI) physiology in a minimally invasive manner. To investigate the effect of testing protocol, gender, age and study country on regional GI transit times and associated pH values using the WMC. Regional GI transit times and pH values were determined in 215 healthy volunteers from USA and Sweden studied using the WMC over a 6.5-year period. The effects of test protocol, gender, age and study country were examined. For GI transit times, testing protocol was associated with differences in gastric emptying time (GET; shorter with protocol 2 (motility capsule ingested immediately after meal) vs. protocol 1 (motility capsule immediately before): median difference: 52 min, P = 0.0063) and colonic transit time (CTT; longer with protocol 2: median 140 min, P = 0.0189), but had no overall effect on whole gut transit time. Females had longer GET (by median 17 min, P = 0.0307), and also longer CTT by (104 min, P = 0.0285) and whole gut transit time by (263 min, P = 0.0077). Increasing age was associated with shorter small bowel transit time (P = 0.002), and study country also influenced small bowel and CTTs. Whole gut and CTTs showed clustering of data at values separated by 24 h, suggesting that describing these measures as continuous variables is invalid. Testing protocol, gender and study country also significantly influenced pH values. Regional GI transit times and pH values, delineated using the wireless motility capsule (WMC), vary based on testing protocol, gender, age and country. Standardisation of testing is crucial for cross-referencing in clinical practice and future research. © 2015 John Wiley & Sons Ltd.
Balcı, Nilay Comuk; Yuruk, Zeliha Ozlem; Zeybek, Aslican; Gulsen, Mustafa; Tekindal, Mustafa Agah
2016-01-01
[Purpose] The aim of our study was to compare the initial effects of scapular proprioceptive neuromuscular facilitation techniques and classic exercise interventions with physiotherapy modalities on pain, scapular dyskinesis, range of motion, and function in adhesive capsulitis. [Subjects and Methods] Fifty-three subjects were allocated to 3 groups: scapular proprioceptive neuromuscular facilitation exercies and physiotherapy modalities, classic exercise and physiotherapy modalities, and only physiotherapy modalities. The intervention was applied in a single session. The Visual Analog Scale, Lateral Scapular Slide Test, range of motion and Simple Shoulder Test were evaluated before and just after the one-hour intervention in the same session (all in one session). [Results] All of the groups showed significant differences in shoulder flexion and abduction range of motion and Simple Shoulder Test scores. There were statistically significant differences in Visual Analog Scale scores in the proprioceptive neuromuscular facilitation and control groups, and no treatment method had significant effect on the Lateral Scapular Slide Test results. There were no statistically significant differences between the groups before and after the intervention. [Conclusion] Proprioceptive neuromuscular facilitation, classic exercise, and physiotherapy modalities had immediate effects on adhesive capsulitis in our study. However, there was no additional benefit of exercises in one session over physiotherapy modalities. Also, an effective treatment regimen for shoulder rehabilitation of adhesive capsulitis patients should include scapular exercises. PMID:27190456
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-09-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee.
Reinforcing effects of caffeine in coffee and capsules.
Griffiths, R R; Bigelow, G E; Liebson, I A
1989-01-01
In a residential research ward the reinforcing and subjective effects of caffeine were studied under double-blind conditions in volunteer subjects with histories of heavy coffee drinking. In Experiment 1, 6 subjects had 13 opportunities each day to self-administer either a caffeine (100 mg) or a placebo capsule for periods of 14 to 61 days. All subjects developed a clear preference for caffeine, with intake of caffeine becoming relatively stable after preference had been attained. Preference for caffeine was demonstrated whether or not preference testing was preceded by a period of 10 to 37 days of caffeine abstinence, suggesting that a recent history of heavy caffeine intake (tolerance/dependence) was not a necessary condition for caffeine to function as a reinforcer. In Experiment 2, 6 subjects had 10 opportunities each day to self-administer a cup of coffee or (on different days) a capsule, dependent upon completing a work requirement that progressively increased and then decreased over days. Each day, one of four conditions was studied: caffeinated coffee (100 mg/cup), decaffeinated coffee, caffeine capsules (100 mg/capsule), or placebo capsules. Caffeinated coffee maintained the most self-administration, significantly higher than decaffeinated coffee and placebo capsules but not different from caffeine capsules. Both decaffeinated coffee and caffeine capsules were significantly higher than placebo capsules but not different from each other. In both experiments, subject ratings of "linking" of coffee or capsules covaried with the self-administration measures. These experiments provide the clearest demonstrations to date of the reinforcing effects of caffeine in capsules and in coffee. PMID:2794839
Effects of sinker shapes on dissolution profiles.
Soltero, R A; Hoover, J M; Jones, T F; Standish, M
1989-01-01
In dissolution testing, according to the U.S. Pharmacopeia, a nonreactive stainless steel wire helix is typically used to sink dosage forms that would otherwise float. The objective of this investigation was to determine if other sinker shapes will influence the rate, extent, or variability of dissolution. Criteria for the optimal sinker were defined. Various new sinker designs were fabricated, tested, and classified. Four classes of sinker shapes were defined: longitudinal, lateral, screen enclosures, and internal weights. Longitudinal sinkers contact the dosage forms on the long axis. Lateral sinkers either wrap around or contact capsule dosage forms in the middle, such as the line where the top and bottom halves of a capsule shell come together. Screen enclosures are of two types: either a wire cage, which holds the entire capsule, or a circular piece of wire screen placed on top of the capsule. Internal weights consist of two steel ball bearings, one inserted into each end of the capsule. The investigation consisted of four studies: (1) visual observation of the dissolution performance using 12 different sinkers; (2) the effect on drug release from nine classified sinkers on two different capsule formulations; (3) side-by-side comparison between the selected optimal longitudinal U clip and the wire helix lateral type sinkers; and (4) hydrodynamic effects caused by the use of the longitudinal U clip and the wire helix lateral type sinkers in the absence of capsule shells. We concluded that capsules sunk with either of the two longitudinal sinkers, the U clip or the paper clip, have faster, more complete dissolution and less variable results than did lateral type sinkers.(ABSTRACT TRUNCATED AT 250 WORDS)
ERIC Educational Resources Information Center
Bashford, Joanne
This information capsule explores the effectiveness of score ranges on the Computerized Placement Test (CPT), used to assess the skills of entry-level students at Miami-Dade Community College and place first-time-in-college students in classes. Data are provided for students entering in Fall terms 1996 and 1997 showing the number of students…
Al-Tabakha, Moawia M; Arida, Adi Issam; Fahelelbom, Khairi M S; Sadek, Bassem; Saeed, Dima Ahmed; Abu Jarad, Rami A; Jawadi, Jeevani
2015-01-01
The purpose of this study was to assess the in vitro performances of "vegetable" capsules in comparison to hard gelatin capsules in terms of shell weight variation, reaction to different humidity conditions, resistance to stress in the absence of moisture, powder leakage, disintegration and dissolution. Two types of capsules made of HPMC produced with (Capsule 2) or without (Capsule 3) a gelling agent and hard gelatin capsules (Capsule 1) were assessed. Shell weight variability was relatively low for all tested capsules shells. Although Capsule 1 had the highest moisture content under different humidity conditions, all capsule types were unable to protect the encapsulated hygroscopic polyvinylpyrrolidone (PVP) powder from surrounding humidity. The initial disintegration for all Capsule 1 occurred within 3 min, but for other types of capsules within 6 min (n = 18). Dissolution of acetaminophen was better when the deionized water (DIW) temperature increased from 32 to 42 °C in case of Capsule 1, but the effect of temperature was not significant for the other types of capsules. Acetaminphen dissolution from Capsule 1 was the fastest (i.e. >90% in 10 min) and independent of the media pH or contents unlike Capsule 2 which was influenced by the pH and dissolution medium contents. It is feasible to use hypromellose capsules shells with or without gelling agent for new lines of pharmaceutical products, however, there is a window for capsule shells manufacturing companies to improve the dissolution of their hypromellose capsules to match the conventional gelatin capsule shells and eventually replace them.
Angelova, N; Hunkeler, D
2001-01-01
Capsules were obtained by interpolymer complexation between chitosan (polycation) and sodium hexametaphosphate (SMP, oligoanion). The effect of the preparation conditions on the capsule characteristics was evaluated. Specifically, the influence of variables such as pH, ionic strength, reagent concentration, and additives on the capsule permeability properties was investigated using dextran as a model permeant. The capsule membrane permeability was found to increase by decreasing the chitosan/SMP ratio as well as adding mannitol to the oligoanion recipient bath. Increasing the ionic strength or the pH of the initial chitosan solution was also found to enhance the membrane permeability, moving the membrane exclusion limit to higher values. Generally, the capsules prepared tinder all tested conditions had a relatively low permeability which rarely exceeded a molecular cut-off of 40 kD based on dextran standards. Furthermore, the diffusion rate showed a strong temporal dependence, indicating that the capsules prepared under various conditions exhibit different apparent pore size densities on the surface. The results indicated that, in order to obtain the desired capsule mass-transfer properties, the preparation conditions should be carefully considered and adjusted. Adding a polyol as well as low salt amount (less than 0.15%) is preferable as a means of modulating the diffusion characteristics, without disturbing the capsule mechanical stability.
1958-08-05
Photographed on: 08 05 1958. -- Impact test conducted by Langley's Hydrodynamics Division. The Division conducted a series of impact studies with full scale and model capsules of the original capsule shape A. Joseph Shortal wrote (Vol. 3, p. 16): The basic design of the capsule was made by M.A. Faget and his coworkers at PARD during the winter of 1957-1958. It was natural, then, that extensive use was made of the facilities at Wallops during the development of the spacecraft. The tests at Wallops consisted of 26 full-size capsules, either launched from the ground by rocket power or dropped from airplanes at high altitude and 28 scaled models, either rocket boosted or released from balloons. Emphasis in the Wallops program was on dynamic stability and aerodynamic heating of the capsule, and effectiveness of the pilot-escape and parachute-recovery systems. The biggest part of the Wallops program was the series of full-size capsules, rocket launched with the Little Joe booster, developed especially for Mercury. -- Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.
1958-09-07
Photographed on: 08 05 1958. -- Impact test conducted by Langley's Hydrodynamics Division. The Division conducted a series of impact studies with full scale and model capsules of the original capsule shape A. Joseph Shortal wrote (Vol. 3, p. 16): The basic design of the capsule was made by M.A. Faget and his coworkers at PARD during the winter of 1957-1958. It was natural, then, that extensive use was made of the facilities at Wallops during the development of the spacecraft. The tests at Wallops consisted of 26 full-size capsules, either launched from the ground by rocket power or dropped from airplanes at high altitude and 28 scaled models, either rocket boosted or released from balloons. Emphasis in the Wallops program was on dynamic stability and aerodynamic heating of the capsule, and effectiveness of the pilot-escape and parachute-recovery systems. The biggest part of the Wallops program was the series of full-size capsules, rocket launched with the Little Joe booster, developed especially for Mercury. -- Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.
AGR-5/6/7 Irradiation Test Predictions using PARFUME
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skerjanc, William F.
PARFUME, (PARticle FUel ModEl) a fuel performance modeling code used for high temperature gas-cooled reactors (HTGRs), was used to model the Advanced Gas Reactor (AGR)-5/6/7 irradiation test using predicted physics and thermal hydraulics data. The AGR-5/6/7 test consists of the combined fifth, sixth, and seventh planned irradiations of the AGR Fuel Development and Qualification Program. The AGR-5/6/7 test train is a multi-capsule, instrumented experiment that is designed for irradiation in the 133.4-mm diameter north east flux trap (NEFT) position of Advanced Test Reactor (ATR). Each capsule contains compacts filled with uranium oxycarbide (UCO) unaltered fuel particles. This report documents themore » calculations performed to predict the failure probability of tristructural isotropic (TRISO)-coated fuel particles during the AGR-5/6/7 experiment. In addition, this report documents the calculated source term from the driver fuel. The calculations include modeling of the AGR-5/6/7 irradiation that is scheduled to occur from October 2017 to April 2021 over a total of 13 ATR cycles, including nine normal cycles and four Power Axial Locator Mechanism (PALM) cycle for a total between 500 – 550 effective full power days (EFPD). The irradiation conditions and material properties of the AGR-5/6/7 test predicted zero fuel particle failures in Capsules 1, 2, and 4. Fuel particle failures were predicted in Capsule 3 due to internal particle pressure. These failures were predicted in the highest temperature compacts. Capsule 5 fuel particle failures were due to inner pyrolytic carbon (IPyC) cracking causing localized stresses concentrations in the SiC layer. This capsule predicted the highest particle failures due to the lower irradiation temperature. In addition, shrinkage of the buffer and IPyC layer during irradiation resulted in formation of a buffer-IPyC gap. The two capsules at the two ends of the test train, Capsules 1 and 5 experienced the smallest buffer-IPyC gap formation due to the lower irradiation fluences and temperatures. Capsule 3 experienced the largest buffer-IPyC gap formation of just under 24 µm. The release fraction of fission products Ag, Cs, and Sr silver (Ag), cesium (Cs), and strontium (Sr) vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 3, reaching up to 84.8% for the TRISO fuel particles. The release fraction of the other two fission products, Cs and Sr are much smaller and, in most cases, less than 1%. The notable exception is again in Capsule 3, where the release fraction for Cs and Sr reach up to 9.7% and 19.1%, respectively.« less
Effect of Shufeng Jiedu capsules as a broad-spectrum antibacterial.
Bao, Yanyan; Gao, Yingjie; Cui, Xiaolan
2016-02-01
This study sought to investigate the broad-spectrum antibacterial action of an alternative medicine, Shufeng Jiedu capsules (SFJDC). Antibacterial testing was performed to determine whether SFJDC had broad-spectrum antibacterial action in vitro, and testing was performed to verify whether SFJDC prevented death due to a Streptococcus or Staphylococcus aureus infection in mice. Results of antibacterial testing suggested that SFJDC are a broad-spectrum antibacterial and that SFJDC are superior to Lianhua Qingwen capsules as a broad-spectrum antibacterial. Results of testing revealed that SFJDC lowered the mortality rate, it reduced mortality, it increased average survival time, and it increased the lifespan of mice dying due to a Staphylococcus aureus or Streptococcus infection. Thus, SFJDC could become a complement to broad-spectrum antimicrobials in clinical settings.
NASA Technical Reports Server (NTRS)
Gahn, R. F.
1974-01-01
The effects were studied of low-pressure air on contamination and corrosion in the tantalum alloy T-111/lithium system at 980 and 1260 C. Capsules of T-111 containing lithium were exposed to six vacuum levels between 1 x 10 to the 8th power and 0.0003 torr by controlled air leakage into a vacuum system. Capsules exposed at 980 C and 0.0002 torr failed from intragranular oxidation. The remainder of the capsules completed the 96-hour tests. The depth of oxygen contamination was greater at 980 C than at 1260 C. Tests made at 0.0001 and 0.00001 torr levels caused large increases in the oxygen content of the T-111. Tests at 0.000001 torr or less produced no significant contamination. No lithium corrosion of the T-111 was observed under any of the conditions.
Pissinati, Rafael; Oliveira, Wanderley Pereira
2003-05-01
The present study was conducted in order to analyze the viability of the spouted bed process for application of a gastric-resistant coating to soft gelatin capsules. The variables investigated were: included angle of conical base, (gamma), the relation between the feed mass flow rate of the coating suspension and the feed mass flow rate of spouting gas (W(s)/W(g)); the ratio between the flow rate of the spouting gas and the flow rate at minimum spouting condition (Q/Q(ms)); the mass of capsules in the bed (M(0)), and the capsule's size. The product quality was measured by disintegration tests, traction x deformation tests, image analysis and by the evaluation of the coating mass distribution and shape factor variation during the coating operation. The experiments were performed in a spouted bed with a column diameter of 200 mm and included a conical base angle of 40 degrees. The best coating efficiency values were obtained for M(0)=300 g. Coating efficiency tended to increase with increasing W(s)/W(g) ratio. Disintegration tests showed that the gastric-resistant effect was obtained with a coating mass of 3.86 mg/cm(2). The shape factor increase during the coating operation. The capsule's coating mass distribution tended to maintain the original distribution.
Investigation of albumin-derived perfluorocarbon-based capsules by holographic optical trapping
Köhler, Jannis; Ruschke, Jegor; Ferenz, Katja Bettina; Esen, Cemal; Kirsch, Michael; Ostendorf, Andreas
2018-01-01
Albumin-derived perfluorocarbon-based capsules are promising as artificial oxygen carriers with high solubility. However, these capsules have to be studied further to allow initial human clinical tests. The aim of this paper is to provide and characterize a holographic optical tweezer to enable contactless trapping and moving of individual capsules in an environment that mimics physiological (in vivo) conditions most effectively in order to learn more about the artificial oxygen carrier behavior in blood plasma without recourse to animal experiments. Therefore, the motion behavior of capsules in a ring shaped or vortex beam is analyzed and optimized on account of determination of the optical forces in radial and axial direction. In addition, due to the customization and generation of dynamic phase holograms, the optical tweezer is used for first investigations on the aggregation behavior of the capsules and a statistical evaluation of the bonding in dependency of different capsule sizes is performed. The results show that the optical tweezer is sufficient for studying individual perfluorocarbon-based capsules and provide information about the interaction of these capsules for future use as artificial oxygen carriers. PMID:29552409
Barham, Ahmad S; Tewes, Frederic; Healy, Anne Marie
2015-01-30
The primary objective of this paper is to compare the sorption characteristics of hydroxypropylmethylcellulose (HPMC) and hard gelatin (HG) capsules and their ability to protect capsule contents. Moisture sorption and desorption isotherms for empty HPMC and HG capsules have been investigated using dynamic vapour sorption (DVS) at 25°C. All sorption studies were analysed using the Young-Nelson model equations which distinguishes three moisture sorption types: monolayer adsorption moisture, condensation and absorption. Water vapour diffusion coefficients (D), solubility (S) and permeability (P) parameters of the capsule shells were calculated. ANOVA was performed with the Tukey comparison test to analyse the effect of %RH and capsule type on S, P, and D parameters. The moisture uptake of HG capsules were higher than HPMC capsules at all %RH conditions studied. It was found that values of D and P across HPMC capsules were greater than for HG capsules at 0-40 %RH; whereas over the same %RH range S values were higher for HG than for HPMC capsules. S values decreased gradually as the %RH was increased up to 60% RH. To probe the effect of moisture ingress, spray dried lactose was loaded into capsules. Phase evolution was characterised by scanning electron microscopy (SEM), X-ray powder diffraction (XRD), and differential scanning calorimetry (DSC). The capsules under investigation are not capable of protecting spray dried lactose from induced solid state changes as a result of moisture uptake. For somewhat less moisture sensitive formulations, HPMC would appear to be a better choice than HG in terms of protection of moisture induced deterioration. Copyright © 2014 Elsevier B.V. All rights reserved.
Li, Hao; Yao, Ming-Jiang; Zhao, Wen-Ming; Guan, Jie; Cai, Lin-Lin; Cui, Ling
2008-01-01
To observe the effect and explore the mechanism of Huannao Yicong capsule in treating senile patients with mild cognitive impairment (MCI). The investigational drugs were packed by blind method. A randomized, double-blind and controlled trial was conducted on ninety senile patients with MCI. Other forty-five senile healthy persons were recruited to the healthy control group. The ninety senile patients were randomly divided into the Huannao Yicong capsule-treated group (45 patients administered with three Huannao Yicong capsules and two aniracetam capsule analogues) and aniracetam-treated group (45 patients treated with two aniracetam capsules and three Huannao Yicong capsule analogues). Patients in the two groups were treated three times daily for 16 weeks. Memory, traditional Chinese medicine syndrome, cerebral blood flow, free radicals and inflammatory mediators, such as superoxide dismutase (SOD), malondialdehyde (MDA), acetylcholinesterase (AchE), interleukin-1alpha (IL-1alpha) and interleukin-6 (IL-6) were determined before and after the treatment. Blood lipids, including triglyceride (TG), total cholesterol (TC), low density lipoprotein cholesterol (LDL-C), high density lipoprotein cholesterol (HDL-C), apolipoprotein A-1 (ApoA-1) and apolipoprotein B-100 (ApoB-100), were detected before and after the treatment. The safety indexes, such as routine tests of blood and urine, hepatic and renal function tests and electrocardiogram (ECG) were taken before and after the treatment. Index score of clinical memory scale in senile healthy people was significantly higher than that in MCI patients before treatment (P<0.01), and the content of AchE, IL-1alpha and IL-6 was obviously lower (P<0.01, P<0.05), the activity of SOD was higher (P<0.05). No significant difference was found in direction memory of clinical memory scale between the two treatment groups. Other index scores of clinical memory scale and traditional Chinese medicine syndrome in patients of Huannao Yicong capsule-treated group were significantly improved as compared with those of the aniracetam-treated group (P<0.05, P<0.01). The blood flow parameters of anterior cerebral artery, posterior cerebral artery and resistant index in patients of Huannao Yicong capsule-treated group were increased significantly (P<0.01, P<0.05). Huannao Yicong capsule could significantly increase the activity of serum SOD and decrease the content of AchE, IL-1alpha and IL-6 (P<0.01, P<0.05), better than aniracetam. Furthermore, Huannao Yicong capsule could significantly improve the blood lipid, such as the level of TG, LDL-C, HDL-C, ApoA-1 and ApoB-100 (P<0.01, P<0.05), and better than aniracetam (P<0.01, P<0.05). No significant changes were found after treatment in safety indexes, such as routine tests of blood and urine, hepatic and renal function tests and ECG. Huannao Yicong capsule has better therapeutic effect than aniracetam capsule in treating senile mild cognitive impairment.
Oshika, T.; Nagata, T.; Ishii, Y.
1998-01-01
AIMS—To investigate the adhesion characteristics of several intraocular lenses (IOLs) to the simulated and rabbit lens capsule. METHODS—Adhesive force to bovine collagen sheets was measured in water with polymethylmethacrylate (PMMA), three piece silicone, and acrylic foldable IOLs. In rabbit eyes, phacoemulsification and IOL implantation were performed. Three weeks later, adhesion between the anterior/posterior capsules and IOL optic was tested, and the capsule was examined histologically. RESULTS—The mean adhesive force to the collagen sheet was 1697 (SD 286) mg for acrylic foldable, 583 (49) mg for PMMA, and 0 mg for silicone IOLs (p=0.0003, Kruskal-Wallis test). Scores (0-5) of adhesion between rabbit anterior capsule and IOL optic were 4.50 (0.55) for acrylic foldable, 3.20 (0.84) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.004). Scores between rabbit posterior capsule and IOL optic displayed a similar tendency; 4.50 (0.84) for acrylic foldable, 3.00 (1.00) for PMMA, and 0.40 (0.55) for silicone IOLs (p=0.021). Histological observation indicated that the edge of IOL optic suppressed the migration of lens epithelial cells towards the centre of the posterior capsule. This inhibitory effect was most pronounced with acrylic foldable IOL and least with silicone IOL. CONCLUSIONS—The acrylic foldable IOL adhered to the lens capsule more than the PMMA IOL, and the silicone IOL showed no adhesiveness. These differences seem to play a role in preventing lens epithelial cells from migrating and forming posterior capsule opacification. Keywords: intraocular lens; lens capsule; posterior capsule opacification; adhesion PMID:9713064
1958-06-24
Testing of Mercury Capsule Shape A by the Hydrodynamics Division of Langley. Joseph Shortal wrote (vol. 3, p. 19): The Hydrodynamics Division provided assistance in determining landing loads. In this connection, after PARD engineers had unofficially approached that division to make some water impact tests with the boilerplate capsule, J.B. Parkinson, Hydrodynamics Chief visited Shortal to find out if the request had his support. Finding out that it did, Parkinson said, Its your capsule. If you want us to drop it in the water, we will do it. From Shortal (Vol. 3, p. 16): The basic design of the capsule was made by M.A. Faget and his coworkers at PARD during the winter of 1957-1958. It was natural, then, that extensive use was made of the facilities at Wallops during the development of the spacecraft. The tests at Wallops consisted of 26 full-size capsules, either launched from the ground by rocket power or dropped from airplanes at high altitude and 28 scaled models, either rocket boosted or released from balloons. Emphasis in the Wallops program was on dynamic stability and aerodynamic heating of the capsule, and effectiveness of the pilot-escape and parachute-recovery systems. The biggest part of the Wallops program was the series of full-size capsules, rocket launched with the Little Joe booster, developed especially for Mercury. -- Published in Joseph A. Shortal, History of Wallops Station: Origins and Activities Through 1949, (Wallops Island, VA: National Aeronautics and Space Administration, Wallops Station, nd), Comment Edition.
Effect of a controlled-release albendazole capsule on parasitism and productivity of sheep.
Corba, J; Krupicer, I; Legény, J; Juris, P; Veselý, L
1991-11-01
The efficacy of intraruminal albendazole (ABZ) capsules (Profitril-Captec) and the effect of treatment on productivity were studied in 300 ewes infected with gastrointestinal nematodes and the trematode Dicrocoelium dendriticum. Coprological tests revealed that treated animals remained negative for 10 weeks after the administration of capsules. Contamination of pasture with nematode larvae was significantly reduced during the whole experiment. Necropsy of 14 animals (seven treated and seven untreated) showed 96.9-99.2% efficacy against the nematodes Nematodirus spp., Oesophagostomum spp., Cooperia spp., Trichostrongylus spp. and Trichuris ovis, while efficacy was 88.5% against D. dendriticum. During the 6 month pasture season (May-October 1989), treated ewes produced on average 2.56 kg cheese and 0.6 kg wool per ewe more than untreated controls. Our study confirms the reliability of the ABZ slow-release capsules over 90 days and the positive effect of treatment on nematode contamination of pasture and ewe productivity.
The development of pyro shock test requirements for Viking Lander Capsule components
NASA Technical Reports Server (NTRS)
Barrett, S.
1975-01-01
The procedure used to derive component-level pyro shock specifications for the Viking Lander Capsule (VLC) is described. Effects of shock path distance and mechanical joints between the device and the point at which the environment is to be estimated are accounted for in the method. The validity of the prediction technique was verified by a series of shock tests on a full-scale structural model of the lander body.
AGR-2 Irradiation Test Final As-Run Report, Rev 2
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collin, Blaise P.
2014-08-01
This document presents the as-run analysis of the AGR-2 irradiation experiment. AGR-2 is the second of the planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the U.S. Department of Energy as part of the Very High Temperature Reactor (VHTR) Technical Development Office (TDO) program. The objectives of the AGR-2 experiment are to: (a) Irradiate UCO (uranium oxycarbide) and UO 2 (uranium dioxide) fuel produced in a large coater. Fuel attributes are based on results obtained from the AGR-1 test and other project activities. (b) Provide irradiated fuel samplesmore » for post-irradiation experiment (PIE) and safety testing. (c) Support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. The primary objective of the test was to irradiate both UCO and UO 2 TRISO (tri-structural isotropic) fuel produced from prototypic scale equipment to obtain normal operation and accident condition fuel performance data. The UCO compacts were subjected to a range of burnups and temperatures typical of anticipated prismatic reactor service conditions in three capsules. The test train also includes compacts containing UO 2 particles produced independently by the United States, South Africa, and France in three separate capsules. The range of burnups and temperatures in these capsules were typical of anticipated pebble bed reactor service conditions. The results discussed in this report pertain only to U.S. produced fuel. In order to achieve the test objectives, the AGR-2 experiment was irradiated in the B-12 position of the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) for a total irradiation duration of 559.2 effective full power days (EFPD). Irradiation began on June 22, 2010, and ended on October 16, 2013, spanning 12 ATR power cycles and approximately three and a half calendar years. The test contained six independently controlled and monitored capsules. Each U.S. capsule contained 12 compacts of either UCO or UO2 AGR coated fuel. No fuel particles failed during the AGR-2 irradiation. Final burnup values on a per compact basis ranged from 7.26 to 13.15% FIMA (fissions per initial heavy-metal atom) for UCO fuel, and 9.01 to 10.69% FIMA for UO 2 fuel, while fast fluence values ranged from 1.94 to 3.47 x 10 25 n/m 2 (E >0.18 MeV) for UCO fuel, and from 3.05 to 3.53 x 10 25 n/m 2 (E >0.18 MeV) for UO 2 fuel. Time-average volume-average (TAVA) temperatures on a capsule basis at the end of irradiation ranged from 987°C in Capsule 6 to 1296°C in Capsule 2 for UCO, and from 996 to 1062°C in UO 2-fueled Capsule 3. By the end of the irradiation, all of the installed thermocouples (TCs) had failed. Fission product release-to-birth (R/B) ratios were quite low. In the UCO capsules, R/B values during the first three cycles were below 10 -6 with the exception of the hotter Capsule 2, in which the R/Bs reached 2 x 10 -6. In the UO 2 capsule (Capsule 3), the R/B values during the first three cycles were below 10 -7. R/B values for all following cycles are not reliable due to gas flow and cross talk issues.« less
[Evaluation of nopal capsules in diabetes mellitus].
Frati Munari, A C; Vera Lastra, O; Ariza Andraca, C R
1992-01-01
To find out if commercial capsules with dried nopal (prickle-pear cactus, Opuntia ficus indica may have a role in the management of diabetes mellitus, three experiments were performed: 30 capsules where given in fasting condition to 10 diabetic subjects and serum glucose was measured through out 3 hours; a control test was performed with 30 placebo capsules. OGTT with previous intake of 30 nopal or placebo capsules was performed in ten healthy individuals. In a crossover and single blinded study 14 diabetic patients withdrew the oral hypoglycemic treatment and received 10 nopal or placebo capsules t.i.d. during one week; serum glucose, cholesterol and tryglycerides levels were measured before and after each one-week period. Five healthy subjects were also studied in the same fashion. Opuntia capsules did not show acute hypoglycemic effect and did not influence OGTT. In diabetic patients serum glucose, cholesterol and tryglycerides levels did not change with Opuntia, but they increased with placebo (P < 0.01 glucose and cholesterol, P = NS triglycerides). In healthy individuals glycemia did not change with nopal, while cholesterol and triglycerides decreased (P < 0.01 vs. placebo). The intake of 30 Opuntia capsules daily in patients with diabetes mellitus had a discrete beneficial effect on glucose and cholesterol. However this dose is unpractical and at present it is not recommended in the management of diabetes mellitus.
Comparative Bioavailability of Sulindac in Capsule and Tablet Formulations
Reid, Joel M.; Mandrekar, Sumithra J.; Carlson, Elsa C.; Harmsen, W. Scott; Green, Erin M.; McGovern, Renee M.; Szabo, Eva; Ames, Matthew M.; Boring, Daniel; Limburg, Paul J.
2008-01-01
The cyclooxygenase-2 (COX-2) enzyme appears to be an important target for cancer chemoprevention. Given the recent emergence of potentially serious cardiovascular toxicity associated with selective COX-2 inhibitors, nonsteroidal antiinflammatory drugs (NSAIDs), which inhibit both COX-1 and COX-2, have received renewed attention as candidate chemoprevention agents. Sulindac has demonstrated consistent chemopreventive potential in preclinical studies, as well as in a limited number of clinical trials reported to date. For the current pharmacokinetic study, sulindac capsules were prepared to facilitate ample agent supplies for future intervention studies. Encapsulation of the parent compound (sulindac sulfoxide) can be readily accomplished, but the effects of alternate formulations on bioavailability have not been rigorously examined. In the present single-dose, two-period crossover trial, we conducted pharmacokinetic analyses of sulindac in capsule (test) versus tablet (reference) formulations. Overall, bioavailability appeared to be higher for the capsule compared to the tablet formulation, based on test-to-reference pharmacokinetic parameter ratios for the parent compound. However, additional analyses based on the sulfide and sulfone metabolites of sulindac with the same pharmacokinetic parameters indicated similar chemopreventive exposures between the capsule and tablet formulations. These data support the use of sulindac capsules, which can be readily prepared with matching placebos, in future blinded chemoprevention trials. PMID:18349286
Capsular locomotive microrobot for gastrointestinal tract.
Park, Sukho; Park, Hyunjun; Park, Sungjin; Jee, Changyeol; Kim, Jinseok; Kim, Byungkyu
2006-01-01
Diagnosis using a flexible endoscope in gastro-intestinal tract becomes very important. In addition, the endoscope is a basic tool of diagnosis and treatment for digestive organ. However, the operation of endoscope is very labor intensive work and gives patients some pains. Therefore, the capsule-type endoscope is developed for the diagnosis of digestive organs. For its conveniences for diagnosis, the capsule endoscope comes into the spotlight. However, it is passively moved by the peristaltic waves of gastro-intestinal tract and thus has some limitations for doctor to get the image of the organ and to diagnose more thoroughly. In order to solve these problems, therefore, a locomotive mechanism of capsule endoscopes has being developed. For the locomotion in the gastro-intestinal tract, our proposed capsule-type microrobot has synchronized multiple legs that are actuated by a linear actuator and two mobile cylinders inside of the capsule. For the feasibility test of the proposed locomotive mechanism, a series of in-vitro experiments using small intestine without incision were carried out. In addition, in-vivo animal tests under a general anesthesia are also executed. From the experimental results, we conclude that the proposed locomotive mechanism is not only applicable to micro capsule endoscopes but also effective to advance inside of intestinal tract.
[Effect of a dehydrated extract of nopal (Opuntia ficus indica Mill.) on blood glucose].
Frati-Munari, A C; de León, C; Ariza-Andraca, R; Bañales-Ham, M B; López-Ledesma, R; Lozoya, X
1989-01-01
To assess if a dehydrated extract of nopal stems retains the effect on glycemia of the entire nopal stems two experiments were performed. A. Six patients with type II diabetes mellitus in fasting condition received 30 capsules containing 10.1 +/- 0.3 g of the extract, and serum glucose levels were measured hourly from 0 to 180 minutes. B. Six healthy volunteers received 30 capsules with the extract followed by 74 g of dextrose orally. Serum glucose measurements were made in a similar fashion. In each experiment a control test with empty capsules was performed. Nopal extract did not reduce fasting glycemia in diabetic subjects. Nevertheless, the extract diminished the increase of serum glucose which followed a dextrose load. Peak serum glucose was 20.3 +/- 18.2 mg/dl (X +/- SD) lower in the test with nopal than in the control one (P less than 0.025). Dehydrated extract of nopal (Opuntia ficus-indica Mill) did not show acute hypoglycemic effect, although could attenuate postprandial hyperglycemia.
Levesque, Barrett G; Cipriano, Lauren E; Chang, Steven L; Lee, Keane K; Owens, Douglas K; Garber, Alan M
2010-03-01
The cost effectiveness of alternative approaches to the diagnosis of small-bowel Crohn's disease is unknown. This study evaluates whether computed tomographic enterography (CTE) is a cost-effective alternative to small-bowel follow-through (SBFT) and whether capsule endoscopy is a cost-effective third test in patients in whom a high suspicion of disease remains after 2 previous negative tests. A decision-analytic model was developed to compare the lifetime costs and benefits of each diagnostic strategy. Patients were considered with low (20%) and high (75%) pretest probability of small-bowel Crohn's disease. Effectiveness was measured in quality-adjusted life-years (QALYs) gained. Parameter assumptions were tested with sensitivity analyses. With a moderate to high pretest probability of small-bowel Crohn's disease, and a higher likelihood of isolated jejunal disease, follow-up evaluation with CTE has an incremental cost-effectiveness ratio of less than $54,000/QALY-gained compared with SBFT. The addition of capsule endoscopy after ileocolonoscopy and negative CTE or SBFT costs greater than $500,000 per QALY-gained in all scenarios. Results were not sensitive to costs of tests or complications but were sensitive to test accuracies. The cost effectiveness of strategies depends critically on the pretest probability of Crohn's disease and if the terminal ileum is examined at ileocolonoscopy. CTE is a cost-effective alternative to SBFT in patients with moderate to high suspicion of small-bowel Crohn's disease. The addition of capsule endoscopy as a third test is not a cost-effective third test, even in patients with high pretest probability of disease. Copyright 2010 AGA Institute. Published by Elsevier Inc. All rights reserved.
Test Vehicle Forebody Wake Effects on CPAS Parachutes
NASA Technical Reports Server (NTRS)
Ray, Eric S.
2017-01-01
Parachute drag performance has been reconstructed for a large number of Capsule Parachute Assembly System (CPAS) flight tests. This allows for determining forebody wake effects indirectly through statistical means. When data are available in a "clean" wake, such as behind a slender test vehicle, the relative degradation in performance for other test vehicles can be computed as a Pressure Recovery Fraction (PRF). All four CPAS parachute types were evaluated: Forward Bay Cover Parachutes (FBCPs), Drogues, Pilots, and Mains. Many tests used the missile-shaped Parachute Compartment Drop Test Vehicle (PCDTV) to obtain data at high airspeeds. Other tests used the Orion "boilerplate" Parachute Test Vehicle (PTV) to evaluate parachute performance in a representative heatshield wake. Drag data from both vehicles are normalized to a "capsule" forebody equivalent for Orion simulations. A separate database of PCDTV-specific performance is maintained to accurately predict flight tests. Data are shared among analogous parachutes whenever possible to maximize statistical significance.
Fetih, Gihan; Lindberg, Sara; Itoh, Katsuhito; Okada, Naoki; Fujita, Takuya; Habib, Fawsia; Artersson, Per; Attia, Mohammed; Yamamoto, Akira
2005-04-11
In general, absorption enhancing effects of various absorption enhancers were greater in the large intestine than those in the small intestinal regions. Therefore, the effectiveness of absorption enhancers is expected to be remarkably observed, if these enhancers can be delivered to the large intestine with some poorly absorbable drugs after oral administration. In this study, therefore, we examined whether chitosan capsules were effective for the colon-specific delivery of a certain absorption enhancer and can improve the absorption enhancing action of the absorption enhancer after oral administration. 5(6)-Carboxyfluorescein (CF) was used as a model drug to investigate the site-dependent effectiveness of various absorption enhancers by an in situ closed loop method. Sodium glycocholate (NaGC), n-dodecyl-beta-d-maltopyranoside (LM), sodium salicylate (NaSal) and sodium caprate (NaCap) were used as models of absorption enhancers in this study. Overall, the absorption enhancing effects of these enhancers for intestinal absorption of CF were greater in the colon than those in the jejunum and the ileum. Especially, among these enhancers tested in this study, LM showed much greater absorption enhancing effect in the colon than in the jejunum and the ileum. Therefore, LM was selected as a model absorption enhancer to examine the effect of chitosan capsules on the absorption enhancing effect of LM. When CF and LM were orally administered to rats using chitosan capsules, the plasma concentration of CF was much higher than those in other dosage forms including solution and gelatin capsules. Therefore, chitosan capsules may be useful carriers for colon-specific delivery of LM, thereby increasing its absorption enhancing effect from the intestinal membranes.
Ren, Ya-Ping; Sun, Li; Jiang, Wei; Hu, Chun-Ping
2005-05-01
To investigate the effects of glycosides of tripterygium wilfordii (GTW), methyltestosterone and Zhuanggushenjin capsule on nitric oxide synthase (NOS) in rat testes. Forty-five rats were equally divided into 5 groups, and respectively given GTW [10 mg/(kg x d)], methyltestosterone [2 mg/(kg x d)], Zhuanggushenjin capsule [0.3 g/(kg x d)], distilled water plus Tween 80 (control I), and distilled water alone (control II) for 4 weeks. At the end of the 5th week, the immunochemical ABC method was used to observe the effects of the three drugs on the NOS positive Leydig cells of the rats. Compared with control II, the GTW group had a significant decrease in the numbers of nNOS and eNOS positive Leydig cells, the methyltestosterone group showed an increase in the number of nNOS but a decrease in that of eNOS positive Leydig cells, and the Zhuanggushenjin group had an increase in the numbers of both nNOS and eNOS positive Leydig cells. GTW can reduce NO production by inhibiting eNOS and nNOS, and hence influence the spermatogenic process. Zhuanggushenjin capsule plays an important role in improving male sexual function by enhancing nNOS and eNOS expression and NO synthesis.
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2011 CFR
2011-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2013 CFR
2013-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2014 CFR
2014-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2012 CFR
2012-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
21 CFR 343.90 - Dissolution and drug release testing.
Code of Federal Regulations, 2010 CFR
2010-04-01
...) Aspirin capsules. Aspirin capsules must meet the dissolution standard for aspirin capsules as contained in the United States Pharmacopeia (USP) 23 at page 132. (c) Aspirin delayed-release capsules and aspirin delayed-release tablets. Aspirin delayed-release capsules and aspirin delayed-release tablets must meet...
NASA Astrophysics Data System (ADS)
Shibata, A.; Nakano, J.; Ohmi, M.; Kawamata, K.; Nakagawa, T.; Tsukada, T.
2012-03-01
To simulate irradiation assisted stress corrosion cracking (IASCC) behavior by in-pile experiments, it is necessary to irradiate specimens up to a neutron fluence that is higher than the IASCC threshold fluence. Pre-irradiated specimens must be relocated from pre-irradiation capsules to in-pile capsules. Hence, a remote welding machine has been developed. And the integrity of capsule housing for a long term irradiation was evaluated by tensile tests in air and slow strain rate tests in water. Two type specimens were prepared. Specimens were obtained from the outer tubes of capsule irradiated to 1.0-3.9 × 1026 n/m2 (E > 1 MeV). And specimens were irradiated in a leaky capsule to 0.03-1.0 × 1026 n/m2. Elongation more than 15% in tensile test at 423 K was confirmed and no IGSCC fraction was shown in SSRT at 423 K which was estimated as temperature at the outer tubes of the capsule under irradiation.
NASA Astrophysics Data System (ADS)
Harun, N.; Darmawan, E.; Nurani, L. H.
2017-11-01
Hibiscus sabdariffa contains flavonoid, triterpenoid, anthocyanin which function as immunostimulant. H. sabdariffa is considered safe for animal renal; nonetheless, there are known side effects of which need to be further investigated for human renal. This research aims to investigate the effect of calyx capsule-ethanol extract H. sabdariffa for renal function of healthy male and female for 30 days period by monitoring Scr and Clcr component in their blood samples. The method of this experimental research was by pre and post-treatment by involving 20 healthy volunteers who have met inclusion and exclusion criteria. The volunteers have completed the informed consent for this experiment. Furthermore, volunteers were divided into two groups (10 male and 10 female). Each group was given orally 500 mg of calyx capsule-ethanol extract H. sabdariffa per day for 30 days period. Blood tests were taken on day 0, day 30 after consuming the capsule and day 45 (15 days after the last day of capsule intake) in order to measure the Scr and Clcr concentration in the blood samples by using Jaffe dan Cockcroft-Gault method. The results of each sampling day were further analyzed statistically and compared using Repeated ANOVA dan Friedman test. The results suggest that there was a difference in the renal function on day 0, 30 and 45 samplings. However, there was no significant difference in Scr dan Clcr concentrations on female and male volunteers (p>0.05). Specifically, the type of gender affects Scr concentration (p<0.05) however, it does not affect Clcr concentration (p>0.05). In addition, age and Body Mass Index (BMI) does not affect Scr and Clcr concentrations (p>0.05). The side effects discovered through the monitoring increased in mixturition and bloatedness. Calyx capsule-ethanol extract H. sabdariffa does not affect on renal function of healthy volunteers.
Development of thermal protection system of the MUSES-C/DASH reentry capsule
NASA Astrophysics Data System (ADS)
Yamada, Tetsuya; Inatani, Yoshifumi; Honda, Masahisa; Hirai, Ken'ich
2002-07-01
In the final phase of the MUSES-C mission, a small capsule with asteroid sample conducts reentry flight directly from the interplanetary transfer orbit at the velocity over 12 km/s. The severe heat flux, the complicated functional requirements, and small weight budget impose several engineering challenges on the designing of the thermal protection system of the capsule. The heat shield is required to function not only as ablator but also as a structural component. The cloth-layered carbon-phenolic ablator, which has higher allowable stress, is developed in newly-devised fabric method for avoiding delamination due to the high aerodynamic heating. The ablation analysis code, which takes into account of the effect of pyrolysis gas on the surface recession rate, has been developed and verified in the arc-heating tests in the facility environment of broad range of enthalpy level. The capsule was designed to be ventilated during the reentry flight up to about atmospheric pressure by the time of parachute deployment by being sealed with porous flow-restrict material. The designing of the thermal protection system, the hardware specifications, and the ground-based test programs of both MUSES-C and DASH capsule are summarized and discussed here in this paper.
Swain, Paul; Toor, Arifa; Volke, Frank; Keller, Jutta; Gerber, Jeremy; Rabinovitz, Elisha; Rothstein, Richard I
2010-06-01
Remote manipulation of wireless capsule endoscopes might improve diagnostic accuracy and facilitate therapy. To test a new capsule-manipulation system. University hospital. A first-in-human study tested a new magnetic maneuverable wireless capsule in a volunteer. A wireless capsule endoscope was modified to include neodymium-iron-boron magnets. The capsule's magnetic switch was replaced with a thermal one and turned on by placing it in hot water. One imager was removed from the PillCam colon-based capsule, and the available space was used to house the magnets. A handheld external magnet was used to manipulate this capsule in the esophagus and stomach. The capsule was initiated by placing it in a microg of hot water. The capsule was swallowed and observed in the esophagus and stomach by using a gastroscope. Capsule images were viewed on a real-time viewer. The capsule was manipulated in the esophagus for 10 minutes. It was easy to make the capsule turn somersaults and to angulate at the cardioesophageal junction. In the stomach, it was easy to move the capsule back from the pylorus to the cardioesophageal junction and hold/spin the capsule at any position in the stomach. The capsule in the esophagus and stomach did not cause discomfort. Magnetic force varies with the fourth power of distance. This study suggests that remote manipulation of a capsule in the esophagus and stomach of a human is feasible and might enhance diagnostic endoscopy as well as enable therapeutic wireless capsule endoscopy. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Fabrication of capsule assemblies, phase 3
NASA Technical Reports Server (NTRS)
Keeton, A. R.; Stemann, L. G.
1973-01-01
Thirteen capsule assemblies were fabricated for evaluation of fuel pin design concepts for a fast spectrum lithium cooled compact space power reactor. These instrumented assemblies were designed for real time test of prototype fuel pins. Uranium mononitride fuel pins were encased in AISI 304L stainless steel capsules. Fabrication procedures were fully qualified by process development and assembly qualification tests. Instrumentation reliability was achieved utilizing specially processed and closely controlled thermocouple hot zone fabrication and by thermal screening tests. Overall capsule reliability was achieved with an all electron beam welded assembly.
Corrosion of 316 stainless steel in high temperature molten Li2BeF4 (FLiBe) salt
NASA Astrophysics Data System (ADS)
Zheng, Guiqiu; Kelleher, Brian; Cao, Guoping; Anderson, Mark; Allen, Todd; Sridharan, Kumar
2015-06-01
In support of structural material development for the fluoride-salt-cooled high-temperature reactor (FHR), corrosion tests of 316 stainless steel were performed in the potential primary coolant, molten Li2BeF4 (FLiBe) at 700 °C for an exposure duration up to 3000 h. Tests were performed in both 316 stainless steel and graphite capsules. Corrosion in both capsule materials occurred by the dissolution of chromium from the stainless steel into the salt which led to the depletion of chromium predominantly along the grain boundaries of the test samples. The samples tested in graphite capsules showed a factor of two greater depth of corrosion attack as measured in terms of chromium depletion, compared to those tested in 316 stainless steel capsules. The samples tested in graphite capsules showed the formation of Cr7C3 particulate phases throughout the depth of the corrosion layer. Samples tested in both types of capsule materials showed the formation of MoSi2 phase due to increased activity of Mo and Si as a result of Cr depletion, and furthermore corrosion promoted the formation of a α-ferrite phase in the near-surface regions of the 316 stainless steel. Based on the corrosion tests, the corrosion attack depth in FLiBe salt was predicted as 17.1 μm/year and 31.2 μm/year for 316 stainless steel tested in 316 stainless steel and in graphite capsules respectively. It is in an acceptable range compared to the Hastelloy-N corrosion in the Molten Salt Reactor Experiment (MSRE) fuel salt.
Lok, Kris Y W; Chan, Ruth S M; Lee, Vivian W Y; Leung, Patrick W; Leung, Cynthia; Leung, Jason; Woo, Jean
2013-01-01
To test the individual effect of artificial food colorings (AFCs) and a preservative on the behavior of the general Chinese population. One hundred thirty children (70 boys and 60 girls) in Hong Kong with a mean age of 8.64 years were enlisted to the study with a within-subject crossover between AFCs, a preservative (sodium benzoate), and a placebo capsule. Two behavior scores were used including the strengths and weaknesses of attention deficit hyperactivity disorder and normal behavior rating scale and the child behavior checklist-teacher report form. Capsule A containing AFCs and Capsule B containing sodium benzoate had no significant adverse effect compared with placebo in both behavior scores. This result persisted when analysis was restricted to children with 85% consumption of capsule (per protocol analysis). There seem to be no significant associations between AFCs and a preservative on Chinese children's behavior at the age of 8 to 9 years. Future directions and implications of this research are discussed.
Assessment of the quality of simvastatin capsules from compounding pharmacies.
Markman, Blanca Elena Ortega; Rosa, Paulo César Pires; Koschtschak, Maria Regina Walter
2010-12-01
To validate a method for determining the simvastatin content of compounded capsules, using high performance liquid chromatography. Eighteen samples of simvastatin 40 mg capsules from compounding pharmacies in the cities of São Paulo, Guarulhos, São Bernardo do Campo and Campinas, Southeastern Brazil, prescribed for fictitious patients were assessed. The analyses were based on the Brazilian Pharmacopoeia and on the high performance liquid chromatography method, optimized and validated in accordance with national and international standards for identification and quantification tests on compounded capsules. The mean weight of the capsules ranged from 70 mg to 316 mg; four samples presented weight variation outside of the specification. The simvastatin content in the capsules was within the specification in 11 samples. In six, the content ranged from 4% to 87% of the declared quantity, thereby not complying with the content requirements for the active agent. For one sample, no content or uniformity determinations were performed. In the content uniformity test, 15 samples presented indices of less than 85%, with relative standard deviations greater than 6%. Three pharmacies had met the specification in this test. In the dissolution test, eight samples presented unsatisfactory results in the first stage of the test, while the remainder presented inconclusive results. The method used was shown to be suitable for application to quality control, and it revealed the poor quality of the simvastatin capsules produced by some compounding pharmacies.
Mercury Capsule Retrorocket Test in the Altitude Wind Tunnel
1960-09-21
A mechanic at the National Aeronautics and Space Administration (NASA) Lewis Research Center prepares the inverted base of a Mercury capsule for a test of its posigrade retrorockets inside the Altitude Wind Tunnel. In October 1959 NASA’s Space Task Group allocated several Project Mercury assignments to Lewis. The Altitude Wind Tunnel was modified to test the Atlas separation system, study the escape tower rocket plume, train astronauts to bring a spinning capsule under control, and calibrate the capsule’s retrorockets. The turning vanes, makeup air pipes, and cooling coils were removed from the wide western end of the tunnel to create a 51-foot diameter test chamber. The Mercury capsule had a six-rocket retro-package affixed to the bottom of the capsule. Three of these were posigrade rockets used to separate the capsule from the booster and three were retrograde rockets used to slow the capsule for reentry into the earth’s atmosphere. Performance of the retrorockets was vital since there was no backup system. Qualification tests of the retrorockets began in April 1960 on a retrograde thrust stand inside the southwest corner of the Altitude Wind Tunnel. These studies showed that a previous issue concerning the delayed ignition of the propellant had been resolved. Follow-up test runs verified reliability of the igniter’s attachment to the propellant. In addition, the capsule’s retrorockets were calibrated so they would not alter the capsule’s attitude when fired.
Ballistic Range Testing of the Mars Exploration Rover Entry Capsule
NASA Technical Reports Server (NTRS)
Schoenenberger, Mark; Hathaway, Wayne; Yates, Leslie; Desai, Prasun
2005-01-01
Results from a 25 shot ballistic range test of the Mars Exploration Rover (MER) aeroshell are presented. The supersonic pitch damping properties of the MER capsule were characterized between Mach = 1.5 and Mach = 3.5 and total angles-of-attack from 0 degrees to greater than 25 degrees. Three capsule center-of-gravity positions were tested across this range of conditions, 0.27, 0.30 and 0.33 body diameters aft of the nose. Parameter identification results show that the capsule is dynamically unstable at low angles-of-attack across the Mach numbers tested, with instability increasing with lower speeds. This dynamic instability was seen to increase with aft center-of-gravity movement. The MER outer mold line was very similar to the successful Mars Pathfinder capsule with only minor modifications. Pathfinder relied on Viking forced oscillation data for preflight predictions. The pitch damping data calculated from this test program are shown to more accurately reproduce the measured Path finder flight data.
The Orion Test Capsule and a number of other items used in the c
2013-08-07
The Orion Test Capsule and a number of other items used in the capsule recovery at being transported down the James River on a Navy INLS "Improved Navy Lighterage System" from Fort Eustis from where it was loaded. Its liquid route will take them to Little Creek Amphibious Base in Norfolk, where it will stay until scheduled recovery test will be performed.
Cost effective use of audiograms after pediatric temporal bone fractures.
Frisenda, Julia L; Schroeder, James W; Ryan, Maura E; Valika, Taher S; Billings, Kathleen R
2015-11-01
To identify the relationship of pediatric temporal fractures to the incidence and type of hearing loss present. To analyze the timing and utility of audiometric testing in children with temporal bone fractures. Retrospective case series of 50 pediatric patients with temporal bone fractures who were treated at an urban, tertiary care children's hospital from 2008 to 2014. A statistical analysis of predictors of hearing loss after temporal bone fracture was performed. Fifty-three fractures (69.7%) in 50 patients involved the petrous portion of the temporal bone. The mean age of patients was 7.13 years, and 39 (73.6%) were male. A fall was the most common mechanism of injury in 28 (52.8%) patients, followed by crush injury (n=14, 26.2%), and vehicular trauma (n=10, 18.9%). All otic capsule violating fractures were associated with a sensorineural hearing loss (n=4, 7.5%, p=0.002). Three of four otic capsule sparing fractures were associated with ossicular dislocation, with a corresponding mixed or conductive hearing loss on follow up audiometric testing. The majority of otic capsule sparing fracture patients (n=19/43, 44.2%) who had follow up audiograms had normal hearing, and those with otic capsule violating fractures were statistically more likely to have persistent hearing loss than those with otic capsule sparing fractures (p=0.01). Patients with otic capsule violating fractures or those with ossicular disruption are at higher risk for persistent hearing loss. Cost-saving may be accrued by selecting only those patients at high risk for persistent hearing loss for audiometric testing after temporal bone fractures. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
1959-09-08
Big Joe Capsule Launch Pad Activities: This film covers both the Big Joe and a Little Joe Project Mercury flight test with a research and development version of the Mercury capsule. Big Joe was an Atlas missile that successfully launched a boilerplate model of the Mercury capsule on September 9, 1959. The lower half of the capsule was created at NASA Lewis. The scenes include coverage of the assembly and erection of the boosters, delivery of the capsules, mating of the capsules to the boosters, prelaunch views of the capsule and boosters on launchers, mission control, the launches, and recovery.
Hypersonic Wind Tunnel Test of a Flare-type Membrane Aeroshell for Atmospheric Entry Capsules
NASA Astrophysics Data System (ADS)
Yamada, Kazuhiko; Koyama, Masashi; Kimura, Yusuke; Suzuki, Kojiro; Abe, Takashi; Koichi Hayashi, A.
A flexible aeroshell for atmospheric entry vehicles has attracted attention as an innovative space transportation system. In this study, hypersonic wind tunnel tests were carried out to investigate the behavior, aerodynamic characteristics and aerodynamic heating environment in hypersonic flow for a previously developed capsule-type vehicle with a flare-type membrane aeroshell made of ZYLON textile sustained by a rigid torus frame. Two different models with different flare angles (45º and 60º) were tested to experimentally clarify the effect of flare angle. Results indicate that flare angle of aeroshell has significant and complicate effect on flow field and aerodynamic heating in hypersonic flow at Mach 9.45 and the flare angle is very important parameter for vehicle design with the flare-type membrane aeroshell.
Pugliese, M; Bengin, V; Casolino, M; Roca, V; Zanini, A; Durante, M
2010-08-01
Radiation assessment and protection in space is the first step in planning future missions to the Moon and Mars, where mission and number of space travelers will increase and the protection of the geomagnetic shielding against the cosmic radiation will be absent. In this framework, the shielding effectiveness of two flexible materials, Kevlar and Nextel, were tested, which are largely used in the construction of spacecrafts. Accelerator-based tests clearly demonstrated that Kevlar is an excellent shield for heavy ions, close to polyethylene, whereas Nextel shows poor shielding characteristics. Measurements on flight performed onboard of the International Space Station and of the Foton-M3 capsule have been carried out with special attention to the neutron component; shielded and unshielded detectors (thermoluminescence dosemeters, bubble detectors) were exposed to a real radiation environment to test the shielding properties of the materials under study. The results indicate no significant effects of shielding, suggesting that thin shields in low-Earth Orbit have little effect on absorbed dose.
Capsule Escape Tests - Wallops Island
1959-05-14
Caption: Off the pad abort shot at Wallops using Langley PARD designed full scale capsule with Recruit rocket and extended skirt main parachute. Shows sequential images of launch and capsule splashdown.
Spada, C; Spera, G; Riccioni, M; Biancone, L; Petruzziello, L; Tringali, A; Familiari, P; Marchese, M; Onder, G; Mutignani, M; Perri, V; Petruzziello, C; Pallone, F; Costamagna, G
2005-09-01
The current visualization of small-bowel strictures using traditional radiological methods is associated with high radiation doses and false-negative results. These methods do not always reveal small-bowel patency for solids. The aim is to assess the safety of the Given patency system and its ability to detect intestinal strictures in patients with strictures that are known or suspected radiologically. The Given patency capsule is composed of lactose, remains intact in the gastrointestinal tract for 40-100 hours post ingestion, and disintegrates thereafter. A total of 34 patients with small-bowel stricture were prospectively enrolled; 30 had a previous diagnosis of Crohn's disease, three had adhesion syndrome and in one ischemic enteritis was suspected. Of the patients, 15 (44.1 %) had previously undergone surgery. Following ingestion, the capsule was monitored for integrity and transit time, using a specially designed Given scanner and also radiologically. Seventeen patients had been enrolled with the intent of using the patency capsule as a preliminary test in patients with small-bowel strictures before undergoing video capsule endoscopy. 30 patients (88.2 %) retrieved the capsule in the stool; it was intact in 20 (median transit time 22 hours), and disintegrated in 10 patients (median transit time 53 hours). Six patients complained of abdominal pain which disappeared within 24 hours. The scanner successfully indicated the presence of the capsule in 94 % of cases. Ten patients underwent video capsule endoscopy following the patency capsule examination; in all of these the video capsule passed through the small-bowel stricture. This feasibility study has shown that the Given patency capsule is a safe, effective, and convenient tool for assessment of functional patency of the small bowel. It can indicate functional patency even in cases where traditional radiology indicates stricture.
Fujita, Yukiyoshi; Yamamoto, Koujirou; Aomori, Tohru; Murakami, Hirokazu; Horiuchi, Ryuya
2008-10-01
Thalidomide is an important advance in the treatment of multiple myeloma. In Japan thalidomide is now on the approval step for the treatment of multiple myeloma. The drug has some bothersome side effects such as defect of organogenesis, neuropathy, constipation and fatigue, but is likely more effective than standard chemotherapy and is changing multiple myeloma treatment. At this moment, Japanese patients must import the thalidomide preparations from Mexico, Britain and elsewhere, but after approval, they patients will be able to get the new Japanese thalidomide capsules. In order to determine appropriate amounts of Japanese thalidomide capsules in the treatment of multiple myeloma, we compared the dissolution profile and plasma thalidomide concentrations of Japanese and British capsules and Mexican tablets. The dissolution test was performed according to the Japanese and the United States Pharmacopoeia. The pharmacokinetic data for Japanese capsules were obtained from the clinical trial in Japanese subjects and compared with those data published for other formulations. The dissolution rate of the Japanese capsule was the fastest, followed by British and Mexican formulations. The pharmacokinetic profiles of Japanese and British capsules were similar, while the 100 mg Japanese thalidomide capsule demonstrated a 1.6-fold higher maximum plasma concentration than the 200 mg Mexican thalidomide tablet (1.7 vs. 1.1 microg/ml), greatly shortened t(max) (4.5 vs. 6.2 h), and the apparent half life was only one-third of the Mexican tablet (4.8 vs. 13.5 h). A comparison of the dissolution and the pharmacokinetic absorption profiles demonstrated a rank-order correlation. Physicians and pharmacists should be aware of the probable alteration in plasma thalidomide concentration when switching to the Japanese capsule, especially from the Mexican tablet, and should monitor clinical response carefully.
Lin, Han; Paff, Matthew L; Molineux, Ian J; Bull, James J
2017-01-01
Capsule depolymerase enzymes offer a promising class of new antibiotics. In vivo studies are encouraging but it is unclear how well this type of phage product will generalize in therapeutics, or whether different depolymerases against the same capsule function similarly. Here, in vivo efficacy was tested using cloned bacteriophage depolymerases against Escherichia coli strains with three different capsule types: K1, K5, and K30. When treating infections with the cognate capsule type in a mouse thigh model, the previously studied K1E depolymerase rescued poorly, whereas K1F, K1H, K5, and K30 depolymerases rescued well. K30 gp41 was identified as the catalytically active protein. In contrast to the in vivo studies, K1E enzyme actively degraded K1 capsule polysaccharide in vitro and sensitized K1 bacteria to serum killing. The only in vitro correlate of poor K1E performance in vivo was that the purified enzyme did not form the expected trimer. K1E appeared as an 18-mer which might limit its in vivo distribution. Overall, depolymerases were easily identified, cloned from phage genomes, and as purified proteins they proved generally effective.
Electrosprayed Multi-Core Alginate Microcapsules as Novel Self-Healing Containers
NASA Astrophysics Data System (ADS)
Hia, Iee Lee; Pasbakhsh, Pooria; Chan, Eng-Seng; Chai, Siang-Piao
2016-10-01
Alginate microcapsules containing epoxy resin were developed through electrospraying method and embedded into epoxy matrix to produce a capsule-based self-healing composite system. These formaldehyde free alginate/epoxy microcapsules were characterized via light microscope, field emission scanning electron microscope, fourier transform infrared spectroscopy and thermogravimetric analysis. Results showed that epoxy resin was successfully encapsulated within alginate matrix to form porous (multi-core) microcapsules with pore size ranged from 5-100 μm. The microcapsules had an average size of 320 ± 20 μm with decomposition temperature at 220 °C. The loading capacity of these capsules was estimated to be 79%. Under in situ healing test, impact specimens showed healing efficiency as high as 86% and the ability to heal up to 3 times due to the multi-core capsule structure and the high impact energy test that triggered the released of epoxy especially in the second and third healings. TDCB specimens showed one-time healing only with the highest healing efficiency of 76%. The single healing event was attributed by the constant crack propagation rate of TDCB fracture test. For the first time, a cost effective, environmentally benign and sustainable capsule-based self-healing system with multiple healing capabilities and high healing performance was developed.
Electrosprayed Multi-Core Alginate Microcapsules as Novel Self-Healing Containers.
Hia, Iee Lee; Pasbakhsh, Pooria; Chan, Eng-Seng; Chai, Siang-Piao
2016-10-03
Alginate microcapsules containing epoxy resin were developed through electrospraying method and embedded into epoxy matrix to produce a capsule-based self-healing composite system. These formaldehyde free alginate/epoxy microcapsules were characterized via light microscope, field emission scanning electron microscope, fourier transform infrared spectroscopy and thermogravimetric analysis. Results showed that epoxy resin was successfully encapsulated within alginate matrix to form porous (multi-core) microcapsules with pore size ranged from 5-100 μm. The microcapsules had an average size of 320 ± 20 μm with decomposition temperature at 220 °C. The loading capacity of these capsules was estimated to be 79%. Under in situ healing test, impact specimens showed healing efficiency as high as 86% and the ability to heal up to 3 times due to the multi-core capsule structure and the high impact energy test that triggered the released of epoxy especially in the second and third healings. TDCB specimens showed one-time healing only with the highest healing efficiency of 76%. The single healing event was attributed by the constant crack propagation rate of TDCB fracture test. For the first time, a cost effective, environmentally benign and sustainable capsule-based self-healing system with multiple healing capabilities and high healing performance was developed.
Electrosprayed Multi-Core Alginate Microcapsules as Novel Self-Healing Containers
Hia, Iee Lee; Pasbakhsh, Pooria; Chan, Eng-Seng; Chai, Siang-Piao
2016-01-01
Alginate microcapsules containing epoxy resin were developed through electrospraying method and embedded into epoxy matrix to produce a capsule-based self-healing composite system. These formaldehyde free alginate/epoxy microcapsules were characterized via light microscope, field emission scanning electron microscope, fourier transform infrared spectroscopy and thermogravimetric analysis. Results showed that epoxy resin was successfully encapsulated within alginate matrix to form porous (multi-core) microcapsules with pore size ranged from 5–100 μm. The microcapsules had an average size of 320 ± 20 μm with decomposition temperature at 220 °C. The loading capacity of these capsules was estimated to be 79%. Under in situ healing test, impact specimens showed healing efficiency as high as 86% and the ability to heal up to 3 times due to the multi-core capsule structure and the high impact energy test that triggered the released of epoxy especially in the second and third healings. TDCB specimens showed one-time healing only with the highest healing efficiency of 76%. The single healing event was attributed by the constant crack propagation rate of TDCB fracture test. For the first time, a cost effective, environmentally benign and sustainable capsule-based self-healing system with multiple healing capabilities and high healing performance was developed. PMID:27694922
Schiele, Julia T; Penner, Heike; Schneider, Hendrik; Quinzler, Renate; Reich, Gabriele; Wezler, Nikolai; Micol, William; Oster, Peter; Haefeli, Walter E
2015-10-01
We evaluated the prevalence of difficulties swallowing solid dosage forms in patients with stroke-induced dysphagia and whether swallowing tablets/capsules increases their risk of penetration and aspiration. Concurrently, we explored whether routinely performed assessment tests help identify patients at risk. Using video endoscopy, we evaluated how 52 patients swallowed four different placebos (round, oval, and oblong tablets and a capsule) with texture-modified water (TMW, pudding consistency) and milk and rated their swallowing performance according to the Penetration Aspiration Scale (PAS). Additionally, Daniels Test, Bogenhausener Dysphagiescore, Scandinavian Stroke Scale, Barthel Index, and Tinetti's Mobility Test were conducted. A substantial proportion of the patients experienced severe difficulties swallowing solid oral dosage forms (TMW: 40.4 %, milk: 43.5 %). Compared to the administration of TMW/milk alone, the placebos increased the PAS values in the majority of the patients (TMW: median PAS from 1.5 to 2.0; milk: median PAS from 1.5 to 2.5, each p value <0.0001) and residue values were significantly higher (p < 0.05). Whereas video-endoscopic examination reliably identified patients with difficulties swallowing medication, neither patients' self-evaluation nor one of the routinely performed bedside tests did. Therefore, before video-endoscopic evaluation, many drugs were modified unnecessarily and 20.8 % of these were crushed inadequately, although switching to another dosage form or drug would have been possible. Hence, safety and effectiveness of swallowing tablets and capsules should be evaluated routinely in video-endoscopic examinations, tablets/capsules should rather be provided with TMW than with milk, and the appropriateness of "non per os except medication" orders for dysphagic stroke patients should be questioned.
Nikzad, Jafar; Shahhosseini, Soraya; Tabarzad, Maryam; Nafissi-Varcheh, Nastaran; Torshabi, Maryam
2017-02-14
In the pharmaceutical industry, hard- and soft-shelled capsules are typically made from gelatin, commonly derived from bovine and porcine sources. To ensure that pharmaceutical products comply with halal regulations in Muslim countries (no porcine products allowed), development of a valid, reliable, quick, and most importantly, cost-effective tests are of utmost importance. We developed a species-specific duplex polymerase chain reaction (PCR) assay targeting 149 bp porcine and 271 bp bovine mitochondrial DNA (mtDNA) to simultaneously detect both porcine and bovine DNA (in one reaction at the same time) in gelatin. Some additional simplex PCR tests (targeting 126 bp bovine and 212 bp porcine mtDNA) and real-time PCR using a commercially available kit (for identification of porcine DNA) were used to verify the selectivity and sensitivity of our duplex PCR. After optimization of DNA extraction and PCR methods, hard/soft pharmaceutical gelatin capsules (containing drug) were tested for the presence of porcine and/or bovine DNA. Duplex PCR detected the presence of as little as 0.1% porcine DNA, which was more accurate than the commercially available kit. Of all gelatin capsules tested (n = 24), 50% contained porcine DNA (pure porcine gelatin alone or in combination with bovine gelatin). Duplex PCR presents an easy-to-follow, quick, low-cost and reliable method to simultaneously detect porcine and bovine DNAs (>100 bp) in minute amounts in highly processed gelatin-containing pharmaceutical products (with a 0.1% sensitivity for porcine DNA) which may be used for halal authentication. Simultaneous detection of porcine and bovine DNA in gelatin capsules by duplex PCR.
Capsule Design for Blue Light Therapy against Helicobacter pylori.
Li, Zhangyong; Ren, Binbin; Tan, Haiyan; Liu, Shengrong; Wang, Wei; Pang, Yu; Lin, Jinzhao; Zeng, Chen
2016-01-01
A photo-medical capsule that emits blue light for Helicobacter pylori treatment was described in this paper. The system consists of modules for pH sensing and measuring, light-emitting diode driver circuit, radio communication and microcontroller, and power management. The system can differentiate locations by monitoring the pH values of the gastrointestinal tract, and turn on and off the blue light according to the preset range of pH values. Our experimental tests show that the capsule can operate in the effective light therapy mode for more than 32 minutes and the wireless communication module can reliably transmit the measured pH value to a receiver located outside the body.
NASA Technical Reports Server (NTRS)
Watkins, A. Neal; Buck, Gregory M.; Leighty, Bradley D.; Lipford, William E.; Oglesby, Donald M.
2008-01-01
Pressure Sensitive Paint (PSP) and Temperature Sensitive Paint (TSP) were used to visualize and quantify the surface interactions of reaction control system (RCS) jets on the aft body of capsule reentry vehicle shapes. The first model tested was an Apollo-like configuration and was used to focus primarily on the effects of the forward facing roll and yaw jets. The second model tested was an early Orion Crew Module configuration blowing only out of its forward-most yaw jet, which was expected to have the most intense aerodynamic heating augmentation on the model surface. This paper will present the results from the experiments, which show that with proper system design, both PSP and TSP are effective tools for studying these types of interaction in hypersonic testing environments.
Maraia Capsule Flight Testing and Results for Entry, Descent, and Landing
NASA Technical Reports Server (NTRS)
Sostaric, Ronald R.; Strahan, Alan L.
2016-01-01
The Maraia concept is a modest size (150 lb., 30" diameter) capsule that has been proposed as an ISS based, mostly autonomous earth return capability to function either as an Entry, Descent, and Landing (EDL) technology test platform or as a small on-demand sample return vehicle. A flight test program has been completed including high altitude balloon testing of the proposed capsule shape, with the purpose of investigating aerodynamics and stability during the latter portion of the entry flight regime, along with demonstrating a potential recovery system. This paper includes description, objectives, and results from the test program.
NASA Astrophysics Data System (ADS)
Otuya, David O.; Verma, Yogesh; Dong, Jing; Gora, Michalina J.; Tearney, Guillermo J.
2017-02-01
Environmental enteric dysfunction (EED) is a poorly understood disease of the small intestine that causes nutrient malabsorption in children, predominantly from low and middle income countries. The clinical importance of EED is neurological and growth stunting that remains as the child grows into adulthood. Tethered capsule endomicroscopy (TCE) has the potential to improve the understanding of EED and could be used to determine the effectiveness of EED interventions. TCE in the adult esophagus and the duodenum has been demonstrated for Barrett`s esophagus and celiac disease diagnosis, respectively. While adult subjects can independently swallow these capsules, it is likely that infants will not, and, as a result, new strategies for introducing these devices in young children aged 0.5-2 years need to be investigated. Our first approach will be to introduce the TCE devices in infants under the aid of endoscopic guidance. To determine the most effective method, we have tested endoscopic approaches for introducing TCE devices into the small intestine of living swine. These methods will be compared and contrasted to discuss the most effective means for endoscopic tethered capsule introduction into the small intestine.
de la Peña, Amparo; Seger, Mary; Rave, Klaus; Heinemann, Lutz; Silverman, Bernard; Muchmore, Douglas B
2009-09-01
In order to assess pharmacokinetic (PK) and glucodynamic (GD) attributes relevant to the end user of an inhaled insulin, this study examined the exposure and GD effect of doses of AIR inhaled insulin (Eli Lilly and Co., Indianapolis, IN) (AIR is a registered trademark of Alkermes, Inc., Cambridge, MA) by combining capsules of different strengths in healthy subjects. Fifty-nine healthy, nonsmoking, male or female subjects with normal pulmonary function were enrolled in an open-label, randomized, crossover study. Subjects underwent up to five euglycemic glucose clamp procedures, separated by 5-18 days. The five AIR insulin treatments tested included one 6 unit-equivalent (U-eq) capsule containing 2.6 mg of insulin, three 2 U-eq (0.9 mg) capsules (2.7 mg total), one 10 U-eq (3.9 mg) capsule, one 6 U-eq capsule plus two 2 U-eq capsules (4.4 mg total), and two 10 U-eq capsules (7.8 mg total). Samples for PK and GD assessments were taken up to 10 h post-dose. Based on both PK (area under the curve from time 0 to time of return to baseline and maximum concentration) and GD (total amount of glucose infused and maximum glucose infusion rate) responses, administration of a 6 U-eq capsule was equivalent to three 2 U-eq capsules; 90% confidence intervals for the ratios were contained within the interval (0.8, 1.25). Similarly, both overall exposure and glucodynamic response after administration of a 10 U-eq capsule were comparable to the 6 U-eq plus two 2 U-eq capsule combination. AIR insulin exhibited PK dose proportionality and dose-dependent increases in GD responses over the 2.6-7.8 mg dose range. AIR insulin exhibited dose strength interchangeability and dose proportionality after single-dose administration in healthy subjects.
Heat Pipe and Thermal Energy Storage and Corrosion Studies (1988)
1989-06-01
of air environment melting and end cap TIG welding [2]. Because of its severity, vacuum thermal cycling of the salt clad capsules between salt eutectic...melting of the salt under an inert gas atmosphere and welding of the specimen capsules by electron beam welding in contrast to previously used methods...electron beam welding . However, no ill effects were believed to have occurred on the overall testing program. Ultrapure fluoride salts LiF, MgF2, NaF
Yang, S G; Kim, D D; Chung, S J; Shim, C K
2006-05-01
We recently succeeded in preparing soft gelatin capsules containing a new self-nanoemulsifying formulation consisting of cyclosporin A (CsA), triacetin, polyoxyl 40 hydrogenated castor oil, polysorbate 20, medium chain triglycerides and medium chain mono- and diglycerides. The soft capsules containing the new formulation exhibited a significantly improved physical stability in terms of the appearance of the gelatin capsule shells and the composition of the fill mass during long-term storage, compared to commercially available soft capsules containing CsA, in which ethanol was employed as a cosolvent of CsA. In the present study, the influence of a fat-rich meal on the bioavailability of CsA from the soft capsule containing the new formulation (test drug) was evaluated and the results compared to those obtained with a representative soft capsule of CsA. A randomized, open-label, 3-way crossover study was performed in the test capsules and reference soft capsules, in a fasted state or after a fat-rich breakfast. 18 healthy male volunteers received a single dose of the reference formulation (Neoral, Novartis AG, Basel, Switzerland) or test formulation (2 capsules each, 200 mg as CsA) with 240 ml of water with a 1-week washout period between the treatments, after a fat-rich (670 kcal, 45 g fat) breakfast (for the test drug, Treatment A; for the reference drug, Treatment B) or a 12-h fasting (for the test drug, Treatment C). Serial blood samples, collected over a 24-h period after the administration, were assayed for blood CsA concentrations using a specific monoclonal radioimmunoassay. The differences in bioavailability parameters (i.e., AUC(0-24h), AUC(0-infinity) and C(max)) between the treatments were within the range of 80-125% of the reference treatment. An analysis of variance (ANOVA) revealed no significant differences (p > 0.05) between subjects, formulations or periods. The 90% confidence intervals (CI) indicated that the differences between the treatments (Treatments A and B, Treatments A and C) were also within the criteria. These results indicate that the bioavailability of CsA from the test drug is equivalent to reference in the fed state, and is likely to be less influenced by a fat-rich meal. Therefore, the new formulation of CsA using triacetin appears to have an advantage over the commercial soft capsules of CsA using a volatile cosolvent such as ethanol.
Colon Capsule Endoscopy for the Detection of Colorectal Polyps: An Economic Analysis
Palimaka, Stefan; Blackhouse, Gord; Goeree, Ron
2015-01-01
Background Colorectal cancer is a leading cause of mortality and morbidity in Ontario. Most cases of colorectal cancer are preventable through early diagnosis and the removal of precancerous polyps. Colon capsule endoscopy is a non-invasive test for detecting colorectal polyps. Objectives The objectives of this analysis were to evaluate the cost-effectiveness and the impact on the Ontario health budget of implementing colon capsule endoscopy for detecting advanced colorectal polyps among adult patients who have been referred for computed tomographic (CT) colonography. Methods We performed an original cost-effectiveness analysis to assess the additional cost of CT colonography and colon capsule endoscopy resulting from misdiagnoses. We generated diagnostic accuracy data from a clinical evidence-based analysis (reported separately), and we developed a deterministic Markov model to estimate the additional long-term costs and life-years lost due to false-negative results. We then also performed a budget impact analysis using data from Ontario administrative sources. One-year costs were estimated for CT colonography and colon capsule endoscopy (replacing all CT colonography procedures, and replacing only those CT colonography procedures in patients with an incomplete colonoscopy within the previous year). We conducted this analysis from the payer perspective. Results Using the point estimates of diagnostic accuracy from the head-to-head study between colon capsule endoscopy and CT colonography, we found the additional cost of false-positive results for colon capsule endoscopy to be $0.41 per patient, while additional false-negatives for the CT colonography arm generated an added cost of $116 per patient, with 0.0096 life-years lost per patient due to cancer. This results in an additional cost of $26,750 per life-year gained for colon capsule endoscopy compared with CT colonography. The total 1-year cost to replace all CT colonography procedures with colon capsule endoscopy in Ontario is about $2.72 million; replacing only those CT colonography procedures in patients with an incomplete colonoscopy in the previous year would cost about $740,600 in the first year. Limitations The difference in accuracy between colon capsule endoscopy and CT colonography was not statistically significant for the detection of advanced adenomas (≥ 10 mm in diameter), according to the head-to-head clinical study from which the diagnostic accuracy was taken. This leads to uncertainty in the economic analysis, with results highly sensitive to changes in diagnostic accuracy. Conclusions The cost-effectiveness of colon capsule endoscopy for use in patients referred for CT colonography is $26,750 per life-year, assuming an increased sensitivity of colon capsule endoscopy. Replacement of CT colonography with colon capsule endoscopy is associated with moderate costs to the health care system. PMID:26366240
2011-12-02
CAPE CANAVERAL, Fla. – From a boat in the Atlantic Ocean, workers secure lines to an Orion flight test capsule during preparations for testing the capsule as their colleagues look on from the deck of NASA's Liberty Star ship. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Curatolo, William; Liu, Ping; Johnson, Barbara A; Hausberger, Angela; Quan, Ernest; Vendola, Thomas; Vatsaraj, Neha; Foulds, George; Vincent, John; Chandra, Richa
2011-07-01
Commercial azithromycin gelatin capsules (Zithromax®) are known to be bioequivalent to commercial azithromycin tablets (Zithromax®) when dosed in the fasted state. These capsules exhibit a reduced bioavailability when dosed in the fed state, while tablets do not. This gelatin capsule negative food effect was previously proposed to be due to slow and/or delayed capsule disintegration in the fed stomach, resulting in extended exposure of the drug to gastric acid, leading to degradation to des-cladinose-azithromycin (DCA). Azithromycin gelatin capsules were formulated with "superdisintegrants" to provide fast-dissolving capsules, and HPMC capsule shells were substituted for gelatin capsule shells, in an effort to eliminate the food effect. Healthy volunteers were dosed with these dosage forms under fasted and fed conditions; pharmacokinetics were evaluated. DCA pharmacokinetics were also evaluated for the HPMC capsule subjects. In vitro disintegration of azithromycin HPMC capsules in media containing food was evaluated and compared with commercial tablets and commercial gelatin capsules. When the two fast-dissolving capsule formulations were dosed to fed subjects, the azithromycin AUC was 38.9% and 52.1% lower than after fasted-state dosing. When HPMC capsules were dosed to fed subjects, the azithromycin AUC was 65.5% lower than after fasted-state dosing. For HPMC capsules, the absolute fasting-state to fed-state decrease in azithromycin AUC (on a molar basis) was similar to the increase in DCA AUC. In vitro capsule disintegration studies revealed extended disintegration times for commercial azithromycin gelatin capsules and HPMC capsules in media containing the liquid foods milk and Ensure®. Interaction of azithromycin gelatin and HPMC capsules with food results in slowed disintegration in vitro and decreased bioavailability in vivo. Concurrent measurement of serum azithromycin and the acid-degradation product DCA demonstrates that the loss of azithromycin bioavailability in the fed state is largely (and probably entirely) due to gastric degradation to DCA. Capsules can provide a useful and elegant dosage form for almost all drugs, but may result in a negative food effect for drugs as acid-labile as azithromycin.
A Comparison of the Irradiation Creep Behavior of Several Graphites
DOE Office of Scientific and Technical Information (OSTI.GOV)
Burchell, Timothy D; Windes, Will
2016-01-01
Graphite creep strain data from the irradiation creep capsule Advanced Graphite Creep-1 (AGC-1) are reported. This capsule was the first (prototype) of a series of five or six capsules planned as part of the AGC experiment, which was designed to fully characterize the effects of neutron irradiation and the radiation creep behavior of current nuclear graphite. The creep strain data and analysis are reported for the six graphite grades incorporated in the capsule. The AGC-1 capsule was irradiated in the Advanced Test Reactor at Idaho National Laboratory (INL) at approximately 700 C and to a peak dose of 7 dpamore » (displacements per atom). The specimen s final dose, temperature, and stress conditions have been reported by INL and were used during this analysis. The derived creep coefficients (K) were calculated for each grade and were found to compare well to literature data for the creep coefficient, even under the wide range of AGC-1 specimen temperatures. Comparisons were made between AGC-1 data and historical grade data for creep coefficients.« less
Status Report on Irradiation Capsules Designed to Evaluate FeCrAl-UO 2 Interactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Field, Kevin G.; Howard, Richard H.
This status report provides the background and current status of a series of irradiation capsules that were designed and are being built to test the interactions between candidate FeCrAl cladding for enhanced accident tolerant applications and prototypical enriched commercial UO 2 fuel in a neutron radiation environment. These capsules will test the degree, if any, of fuel cladding chemical interactions (FCCI) between FeCrAl and UO 2. The capsules are to be irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory to burn-ups of 10, 30, and 50 GWd/MT with a nominal target temperature at the interfaces between themore » pellets and clad of 350°C.« less
Apparatus and method for simulating material damage from a fusion reactor
Smith, Dale L.; Greenwood, Lawrence R.; Loomis, Benny A.
1989-01-01
An apparatus and method for simulating a fusion environment on a first wall or blanket structure. A material test specimen is contained in a capsule made of a material having a low hydrogen solubility and permeability. The capsule is partially filled with a lithium solution, such that the test specimen is encapsulated by the lithium. The capsule is irradiated by a fast fission neutron source.
Apparatus and method for simulating material damage from a fusion reactor
Smith, D.L.; Greenwood, L.R.; Loomis, B.A.
1988-05-20
This paper discusses an apparatus and method for simulating a fusion environment on a first wall or blanket structure. A material test specimen is contained in a capsule made of a material having a low hydrogen solubility and permeability. The capsule is partially filled with a lithium solution, such that the test specimen is encapsulated by the lithium. The capsule is irradiated by a fast fission neutron source.
Apparatus and method for simulating material damage from a fusion reactor
Smith, Dale L.; Greenwood, Lawrence R.; Loomis, Benny A.
1989-03-07
An apparatus and method for simulating a fusion environment on a first wall or blanket structure. A material test specimen is contained in a capsule made of a material having a low hydrogen solubility and permeability. The capsule is partially filled with a lithium solution, such that the test specimen is encapsulated by the lithium. The capsule is irradiated by a fast fission neutron source.
Lützen, Ulf; Zhao, Yi; Marx, Marlies; Imme, Thea; Assam, Isong; Siebert, Frank‐Andre; Culman, Juraj
2016-01-01
Radiation Protection in Radiology, Nuclear Medicine and Radio Oncology is of the utmost importance. Radioiodine therapy is a frequently used and effective method for the treatment of thyroid disease. Prior to each therapy the radioactivity of the [ 131I]‐capsule must be determined to prevent misadministration. This leads to a significant radiation exposure to the staff. We describe an alternative method, allowing a considerable reduction of the radiation exposure. Two [ 131I]‐capsules (A01=2818.5; A02=73.55.0 MBq) were measured multiple times in their own delivery lead containers — that is to say, [ 131I]‐capsules remain inside the containers during the measurements (shielded measurement) using a dose calibrator and a well‐type and a thyroid uptake probe. The results of the shielded measurements were correlated linearly with the [ 131I]‐capsules radioactivity to create calibration curves for the used devices. Additional radioactivity measurements of 50 [ 131I]‐capsules of different radioactivities were done to validate the shielded measuring method. The personal skin dose rate (HP(0.07)) was determined using calibrated thermo luminescent dosimeters. The determination coefficients for the calibration curves were R2>0.9980 for all devices. The relative uncertainty of the shielded measurement was <6.8%. At a distance of 10 cm from the unshielded capsule the HP(0.07) was 46.18 μSv/(GBq⋅s), and on the surface of the lead container containing the [ 131I]‐capsule the HP(0.07) was 2.99 and 0.27 μSv/(GBq⋅s) for the two used container sizes. The calculated reduction of the effective dose by using the shielded measuring method was, depending on the used container size, 74.0% and 97.4%, compared to the measurement of the unshielded [ 131I]‐capsule using a dose calibrator. The measured reduction of the effective radiation dose in the practice was 56.6% and 94.9 for size I and size II containers. The shielded [ 131I]‐capsule measurement reduces the radiation exposure to the staff significantly and offers the same accuracy of the unshielded measurement in the same amount of time. In order to maintain the consistency of the measuring method, monthly tests have to be done by measuring a [ 131I]‐capsule with known radioactivity. PACS number(s): 93.85.Np, 92.20.Td, 87.50.yk, 87.53.Bn PMID:27455475
Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules.
O'Connor, Sean; O'Connor, Paula Fey; Feng, H Amy; Ashley, Kevin
2014-10-01
An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 - 4 mg of National Institute of Standards and Technology Standard Reference Material ® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision S r at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝ rt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules.
Gravimetric Analysis of Particulate Matter using Air Samplers Housing Internal Filtration Capsules
O'Connor, Sean; O'Connor, Paula Fey; Feng, H. Amy
2015-01-01
Summary An evaluation was carried out to investigate the suitability of polyvinyl chloride (PVC) internal capsules, housed within air sampling devices, for gravimetric analysis of airborne particles collected in workplaces. Experiments were carried out using blank PVC capsules and PVC capsules spiked with 0,1 – 4 mg of National Institute of Standards and Technology Standard Reference Material® (NIST SRM) 1648 (Urban Particulate Matter) and Arizona Road Dust (Air Cleaner Test Dust). The capsules were housed within plastic closed-face cassette samplers (CFCs). A method detection limit (MDL) of 0,075 mg per sample was estimated. Precision Sr at 0,5 - 4 mg per sample was 0,031 and the estimated bias was 0,058. Weight stability over 28 days was verified for both blanks and spiked capsules. Independent laboratory testing on blanks and field samples verified long-term weight stability as well as sampling and analysis precision and bias estimates. An overall precision estimate Ŝrt of 0,059 was obtained. An accuracy measure of ±15,5% was found for the gravimetric method using PVC internal capsules. PMID:26435581
NASA Astrophysics Data System (ADS)
Beretta, Giovanni L.; Folini, Marco; Cavalieri, Francesca; Yan, Yan; Fresch, Enrico; Kaliappan, Subramanian; Hasenöhrl, Christoph; Richardson, Joseph J.; Tinelli, Stella; Fery, Andreas; Caruso, Frank; Zaffaroni, Nadia
2015-03-01
Redox-active polymers and carriers are oxidizing nanoagents that can potentially trigger intracellular off-target effects. In the present study, we investigated the occurrence of off-target effects in prostate cancer cells following exposure to redox-active polymer and thin multilayer capsules with different chemical properties. We show that, depending on the intracellular antioxidant capacity, thiol-functionalized poly(methacrylic acid), PMASH triggers cell defense responses/perturbations that result in off-target effects (i.e., induction of autophagy and down-regulation of survivin). Importantly, the conversion of the carboxyl groups of PMASH into the neutral amides of poly(hydroxypropylmetacrylamide) (pHPMASH) nullified the off-target effects and cytotoxicity in tested cell lines. This suggests that the simultaneous action of carboxyl and disulfide groups in PMASH polymer or capsules may play a role in mediating the intracellular off-target effects. Our work provides evidence that the rational design of redox-active carriers for therapeutic-related application should be guided by a careful investigation on potential disturbance of the cellular machineries related to the carrier association.Redox-active polymers and carriers are oxidizing nanoagents that can potentially trigger intracellular off-target effects. In the present study, we investigated the occurrence of off-target effects in prostate cancer cells following exposure to redox-active polymer and thin multilayer capsules with different chemical properties. We show that, depending on the intracellular antioxidant capacity, thiol-functionalized poly(methacrylic acid), PMASH triggers cell defense responses/perturbations that result in off-target effects (i.e., induction of autophagy and down-regulation of survivin). Importantly, the conversion of the carboxyl groups of PMASH into the neutral amides of poly(hydroxypropylmetacrylamide) (pHPMASH) nullified the off-target effects and cytotoxicity in tested cell lines. This suggests that the simultaneous action of carboxyl and disulfide groups in PMASH polymer or capsules may play a role in mediating the intracellular off-target effects. Our work provides evidence that the rational design of redox-active carriers for therapeutic-related application should be guided by a careful investigation on potential disturbance of the cellular machineries related to the carrier association. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr07240e
Kim, Hee Man; Yang, Sungwook; Kim, Jinseok; Park, Semi; Cho, Jae Hee; Park, Jeong Youp; Kim, Tae Song; Yoon, Eui-Sung; Song, Si Young; Bang, Seungmin
2010-08-01
Capsule endoscopy that could actively move and approach a specific site might be more valuable for the diagnosis or treatment of GI diseases. We tested the performance of active locomotion of a novel wired capsule endoscope with a paddling-based locomotion mechanism, using 3 models: a silicone tube, an extracted porcine colon, and a living pig. In vitro, ex vivo, and in vivo experiments in a pig model. Study in an animal laboratory. For the in vitro test, the locomotive capsule was controlled to actively move from one side of a silicone tube to the other by a controller-operated automatic traveling program. The velocity was calculated by following a video recording. We performed ex vivo tests by using an extracted porcine colon in the same manner we performed the in vitro test. In in vivo experiments, the capsule was inserted into the rectum of a living pig under anesthesia, and was controlled to move automatically forward. After 8 consecutive trials, the velocity was calculated. Elapsed time, velocity, and mucosal damage. The locomotive capsule showed stable and active movement inside the lumen both in vitro and ex vivo. The velocity was 60 cm/min in the silicone tube, and 36.8 and 37.5 cm/min in the extracted porcine colon. In the in vivo experiments, the capsule stably moved forward inside the colon of a living pig without any serious complications. The mean velocity was 17 cm/min over 40 cm length. We noted pinpoint erythematous mucosal injuries in the colon. Porcine model experiments, wired capsule endoscope. The novel paddling-based locomotive capsule endoscope performed fast and stable movement in a living pig colon with consistent velocity. Further investigation is necessary for practical use in humans. Copyright 2010 American Society for Gastrointestinal Endoscopy. Published by Mosby, Inc. All rights reserved.
Axial strength test for round flat faced versus capsule shaped bilayer tablets.
Franck, Jason; Abebe, Admassu; Keluskar, Rekha; Martin, Kyle; Majumdar, Antara; Kottala, Niranjan; Stamato, Howard
2015-03-01
There has been increasing interest in fixed dose combination (FDC) therapy. Multi-layer tablets are a popular choice among various technologies to deliver FDCs. In most cases, round flat faced tooling is used in testing tablets as they have the simplest geometry. However, shaped tooling is more common for commercial products and may have an effect on bilayer tablet strength. Capsule shaped bilayer tablets, similar to a commercial image, and holders conforming to the tablet topology, were compared with similar round flat faced bilayer tablets and their corresponding holders. Bilayer tablets were subjected to an axial test device, until fracture and the quantitative breaking force value was recorded. As the second layer compression force increases, regardless of holder design, an increase in breaking force occurs as expected. This consistent trend provides insight regarding the breaking force of capsule shaped bilayer tablets. The results of this study show that at lower second layer compression forces, tablet geometry does not significantly impact the results. However, at higher compression forces, a significant difference in breaking force between tablet geometries exists. Therefore, using a test geometry close to the final commercial tablet image is recommended to have the most accurate prediction for tablet breakage.
The effect of glicerol and sorbitol plasticizers toward disintegration time of phyto-capsules
NASA Astrophysics Data System (ADS)
Pudjiastuti, Pratiwi; Hendradi, Esti; Wafiroh, Siti; Harsini, Muji; Darmokoesoemo, Handoko
2016-03-01
The aim of research is determining the effect of glycerol and sorbitol toward the disintegration time of phyto-capsules, originated capsules from plant polysaccharides. Phyto-capsules were made from polysaccharides and 0.5% (v/v) of glycerol and sorbitol of each. The seven capsules of each were determined the disintegration time using Erweka disintegrator. The mean of disintegration time of phyto-capsules without plasticizers, with glycerol and sorbitol were 25'30"; 45'15" and 35'30" respectively. The color and colorless gelatin capsules showed the mean of disintegration time 7'30" and 2'35" respectively.
Ultrasonic technique for inspection of GPHS capsule girth weld integrity
NASA Astrophysics Data System (ADS)
Placr, Arnost
1993-05-01
An innovative nondestructive examination (NDE) technique for the inspection of integrity of General Purpose Heat Source (GPHS) capsule girth welds was developed employing a Lamb wave as the mode of the sound propagation. Reliability of the Lamb wave technique was tested on GPHS capsules using plutonium pallet simulators. All ten capsules, which were previously rejected, passed ultrasonic (UT) inspection using the Lamb wave technique.
AGR-1 Irradiation Test Final As-Run Report, Rev. 3
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collin, Blaise P.
2015-01-01
This document presents the as-run analysis of the AGR-1 irradiation experiment. AGR-1 is the first of eight planned irradiations for the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. Funding for this program is provided by the US Department of Energy (DOE) as part of the Next-Generation Nuclear Plant (NGNP) project. The objectives of the AGR-1 experiment are: 1. To gain experience with multi-capsule test train design, fabrication, and operation with the intent to reduce the probability of capsule or test train failure in subsequent irradiation tests. 2. To irradiate fuel produced in conjunction with the AGR fuel processmore » development effort. 3. To provide data that will support the development of an understanding of the relationship between fuel fabrication processes, fuel product properties, and irradiation performance. In order to achieve the test objectives, the AGR-1 experiment was irradiated in the B-10 position of the Advanced Test Reactor (ATR) at the Idaho National Laboratory (INL) for a total duration of 620 effective full power days of irradiation. Irradiation began on December 24, 2006 and ended on November 6, 2009 spanning 13 ATR cycles and approximately three calendar years. The test contained six independently controlled and monitored capsules. Each capsule contained 12 compacts of a single type, or variant, of the AGR coated fuel. No fuel particles failed during the AGR-1 irradiation. Final burnup values on a per compact basis ranged from 11.5 to 19.6 %FIMA, while fast fluence values ranged from 2.21 to 4.39 x 10 25 n/m 2 (E >0.18 MeV). We’ll say something here about temperatures once thermal recalc is done. Thermocouples performed well, failing at a lower rate than expected. At the end of the irradiation, nine of the originally-planned 19 TCs were considered functional. Fission product release-to-birth (R/B) ratios were quite low. In most capsules, R/B values at the end of the irradiation were at or below 10 -7 with only one capsule significantly exceeding this value. A maximum R/B of around 2 x 10 -7 was reached at the end of the irradiation in Capsule 5. Several shakedown issues were encountered and resolved during the first three cycles. These include the repair of minor gas line leaks; repair of faulty gas line valves; the need to position moisture monitors in regions of low radiation fields for proper functioning; the enforcement of proper on-line data storage and backup, the need to monitor thermocouple performance, correcting for detector spectral gain shift, and a change in the mass flow rate range of the neon flow controllers.« less
As-Run Physics Analysis for the UCSB-1 Experiment in the Advanced Test Reactor
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nielsen, Joseph Wayne
2015-09-01
The University of California Santa Barbara (UCSB) -1 experiment was irradiated in the A-10 position of the ATR. The experiment was irradiated during cycles 145A, 145B, 146A, and 146B. Capsule 6A was removed from the test train following Cycle 145A and replaced with Capsule 6B. This report documents the as-run physics analysis in support of Post-Irradiation Examination (PIE) of the test. This report documents the as-run fluence and displacements per atom (DPA) for each capsule of the experiment based on as-run operating history of the ATR. Average as-run heating rates for each capsule are also presented in this report tomore » support the thermal analysis.« less
Herrmann, Evan S; Cooper, Ziva D; Bedi, Gillinder; Ramesh, Divya; Reed, Stephanie C; Comer, Sandra D; Foltin, Richard W; Haney, Margaret
2016-07-01
Each year, over 300,000 individuals in the USA enter treatment for cannabis use disorder (CUD). The development of effective pharmacotherapy for CUD is a priority. This placebo-controlled study examined the effects of zolpidem alone and in combination with nabilone on cannabis withdrawal and a laboratory measure of relapse. Eleven daily, non-treatment-seeking cannabis users completed three, 8-day inpatient phases; each phase tested a different medication condition in counter-balanced order. On the first day of each phase, participants were administered placebo capsules t.i.d. and smoked experimenter-administered active cannabis (5.6 % Δ(9)-tetrahydrocannabinol (THC)). On days 2-8, the participants were administered capsules containing either placebo (0 mg at 0900, 1800, and 2300 hours), zolpidem (0 mg at 0900 and 1800, and 12.5 mg at 2300), or zolpidem (12.5 mg at 2300) and nabilone (3 mg at 0900 and 1800). Cannabis withdrawal, subjective capsule effects, and cognitive performance were examined on days 3-4, when only inactive cannabis (0.0 % THC) was available for self-administration. "Relapse" was measured on days 5-8, when participants could self-administer active cannabis. Both medication conditions decreased withdrawal-related disruptions in sleep, but only zolpidem in combination with nabilone decreased withdrawal-related disruptions in mood and food intake relative to placebo. Zolpidem in combination with nabilone, but not zolpidem alone, decreased self-administration of active cannabis. Zolpidem in combination with nabilone also produced small increases in certain abuse-related subjective capsule ratings, while zolpidem alone did not. Neither medication condition altered cognitive performance. Clinical testing of nabilone, either alone, or in combination with zolpidem is warranted.
Herrmann, Evan S.; Cooper, Ziva D.; Bedi, Gillinder; Ramesh, Divya; Reed, Stephanie C.; Comer, Sandra D.; Foltin, Richard W.; Haney, Margaret
2017-01-01
Rationale Each year over 300,000 individuals in the U.S. enter treatment for Cannabis Use Disorder (CUD). The development of effective pharmacotherapy for CUD is a priority. Objective This placebo-controlled study examined the effects of zolpidem alone and in combination with nabilone on cannabis withdrawal and a laboratory measure of relapse. Methods Eleven daily, non-treatment-seeking cannabis users completed three, 8-day inpatient phases; each phase tested a different medication condition in counter-balanced order. On the first day of each phase, participants were administered placebo capsules t.i.d. and smoked experimenter-administered active cannabis (5.6% THC). On days 2–8, participants were administered capsules containing either placebo (0 mg at 0900, 1800, and 2300), zolpidem (0 mg at 0900 and 1800 and 12.5 mg at 2300) or zolpidem (12.5 mg at 2300) and nabilone (3 mg at 0900 and 1800). Cannabis withdrawal, subjective capsule effects, and cognitive performance were examined on days 3–4, when only inactive cannabis (0.0% THC) was available for self-administration. ‘Relapse’ was measured on days 5–8, when participants could self-administer active cannabis. Results Both medication conditions decreased withdrawal-related disruptions in sleep, but only zolpidem in combination with nabilone decreased withdrawal-related disruptions in mood and food intake relative to placebo. Zolpidem in combination with nabilone, but not zolpidem alone, decreased self-administration of active cannabis. Zolpidem in combination with nabilone also produced small increases in certain abuse-related subjective capsule ratings, while zolpidem alone did not. Neither medication condition altered cognitive performance. Conclusions Clinical testing of nabilone, either alone, or in combination with zolpidem is warranted. PMID:27085870
Kodithuwakku, Nandani Darshika; Pan, Min; Zhu, Yi-lin; Zhang, Yan-yan; Feng, Yi-dong; Fang, Wei-rong; Li, Yun-man
2013-12-12
Shuang-Qi gout capsule is a traditional Chinese medicine prescription, which has been used in the treatment of joint pain, inflammation and gout arthritis. This study evaluates anti-inflammatory and antinociceptive effects of Shuang-Qi gout capsule and its modulation of pro-inflammatory cytokines with special reference to gout arthritis. Anti-inflammatory effect of Shuang-Qi gout capsule was investigated bymice tail-flick response, acetic acid induced writhing response, Xylene-induced auricle inflammation and the hind paw volume of the monosodium urate (MSU) crystal induced rats with different time durations. To investigate the effects on gout arthritis, ankle joint of rats induced by MSU crystals and assessed for edema and histopathological changes. In vitro, prepared serum was incubated with urate crystal induced HUVE cells and the release of TNF-α and IL-1β determined by ELISA. Shuang-Qi gout capsule showed significant and dose dependent anti-inflammatory effect via reducing edema and pain, throughout all the models. The high dose of Shuang-Qi gout capsule and Indomethacin significantly attenuated the edema. Histopathological results showed that high and medium dose of Shuang-Qi gout capsule and Indomethacin reduced gouty joint inflammatory features, while the high dose of Shuang-Qi gout capsule showed a better therapeutic effect. High and medium dose of Shuang-Qi gout capsule significantly reduced the release of TNF-α and IL-1β (p<0.05). Shuang-Qi gout capsule can effectively inhibit the inflammation, analgesia, through the modulation of emission of pro-inflammatory cytokines and the curative effect is dose dependent. Conversely, these MSU induced in vivo and in vitro studies of Shuang-Qi gout capsule suggest that, Shuang-Qi gout capsule may be a potential agent for treatment in gouty arthritis. © 2013 Published by Elsevier Ireland Ltd.
Design and testing of tubular polymeric capsules for self-healing of concrete
NASA Astrophysics Data System (ADS)
Araújo, M.; Van Tittelboom, K.; Feiteira, J.; Gruyaert, E.; Chatrabhuti, S.; Raquez, J.-M.; Šavija, B.; Alderete, N.; Schlangen, E.; De Belie, N.
2017-10-01
Polymeric healing agents have proven their efficiency to heal cracks in concrete in an autonomous way. However, the bottleneck for valorisation of self-healing concrete with polymeric healing agents is their encapsulation. In the present work, the suitability of polymeric materials such as poly(methyl methacrylate) (PMMA), polystyrene (PS) and poly(lactic acid) (PLA) as carriers for healing agents in self-healing concrete has been evaluated. The durability of the polymeric capsules in different environments (demineralized water, salt water and simulated concrete pore solution) and their compatibility with various healing agents have been assessed. Next, a numerical model was used to simulate capsule rupture when intersected by a crack in concrete and validated experimentally. Finally, two real-scale self-healing concrete beams were made, containing the selected polymeric capsules (with the best properties regarding resistance to concrete mixing and breakage upon crack formation) or glass capsules and a reference beam without capsules. The self-healing efficiency was determined after crack creation by 3-point-bending tests.
Polar tent for reduced perturbation of NIF ignition capsules
NASA Astrophysics Data System (ADS)
Hammel, B. A.; Pickworth, L.; Stadermann, M.; Field, J.; Robey, H.; Scott, H. A.; Smalyuk, V.
2016-10-01
In simulations, a tent that contacts the capsule near the poles and departs tangential to the capsule surface greatly reduces the capsule perturbation, and the resulting mass injected into the hot-spot, compared to current capsule support methods. Target fabrication appears feasible with a layered tent (43-nm polyimide + 8-nm C) for increased stiffness. We are planning quantitative measurements of the resulting shell- ρR perturbation near peak implosion velocity (PV) using enhanced self-emission backlighting, achieved by adding 1% Ar to the capsule fill in Symcaps (4He + H). Layered DT implosions are also planned for an integrated test of capsule performance. We will describe the design and simulation predictions. Prepared by LLNL under Contract DE-AC52-07NA27344.
ERIC Educational Resources Information Center
Wheate, Nial J.; Apps, Michael G.; Khalifa, Hazer; Doughty, Alan; Patel, Alpesh Ramanlal
2017-01-01
A laboratory experiment to determine the concentration of the anti-inflammatory drug ibuprofen in liquid gelatin capsule dosage forms, suitable for undergraduate chemistry or pharmacy students, is described. Either individually, or in small teams, the students digest two 200 mg capsules in a KOH solution. While the capsules are digesting the…
Ates, Louis S.; van der Woude, Aniek D.; Bestebroer, Jovanka; van Stempvoort, Gunny; Musters, René J. P.; Garcia-Vallejo, Juan J.; Picavet, Daisy I.; van de Weerd, Robert; Maletta, Massimiliano; Kuijl, Coenraad P.; van der Wel, Nicole N.; Bitter, Wilbert
2016-01-01
Mycobacteria produce a capsule layer, which consists of glycan-like polysaccharides and a number of specific proteins. In this study, we show that, in slow-growing mycobacteria, the type VII secretion system ESX-5 plays a major role in the integrity and stability of the capsule. We have identified PPE10 as the ESX-5 substrate responsible for this effect. Mutants in esx-5 and ppe10 both have impaired capsule integrity as well as reduced surface hydrophobicity. Electron microscopy, immunoblot and flow cytometry analyses demonstrated reduced amounts of surface localized proteins and glycolipids, and morphological differences in the capsular layer. Since capsular proteins secreted by the ESX-1 system are important virulence factors, we tested the effect of the mutations that cause capsular defects on virulence mechanisms. Both esx-5 and ppe10 mutants of Mycobacterium marinum were shown to be impaired in ESX-1-dependent hemolysis. In agreement with this, the ppe10 and esx5 mutants showed reduced recruitment of ubiquitin in early macrophage infection and intermediate attenuation in zebrafish embryos. These results provide a pivotal role for the ESX-5 secretion system and its substrate PPE10, in the capsular integrity of pathogenic mycobacteria. These findings open up new roads for research on the mycobacterial capsule and its role in virulence and immune modulation. PMID:27280885
2011-10-15
Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary. NASA publicly announced plans to build the rocket engine test site Oct. 25, 1961.
NASA Astrophysics Data System (ADS)
Prates, Renato Araujo; Hamblin, Michael R.; Kato, Ilka T.; Fuchs, Beth; Mylonakis, Eleytherios; Simões Ribeiro, Martha; Tegos, George
2011-03-01
Antimicrobial photodynamic inactivation (APDI) is based on the utilization of substances that can photosensitize biological tissues and are capable of being activated in the presence of light. Cryptococcus neoformans is an yeast surrounded by a capsule composed primarily of glucoronoxylomannan that plays an important role in its virulence. This yeast causes infection on skin, lungs and brain that can be associated with neurological sequelae and neurosurgical interventions, and its conventional treatment requires prolonged antifungal therapy, which presents important adverse effects. The aim of this study was to evaluate the protective effect of Cryptococcus neoformans capsule against reactive oxygen species generated by APDI. Cryptococcus neoformans KN99α, which is a strain able to produce capsule, and CAP59 that does not present capsule production were submitted to APDI using methylene blue (MB), rose bengal (RB), and pL-ce6 as photosensitizers (PS). Then microbial inactivation was evaluated by counting colony form units following APDI and confocal laser scanning microscopy (CLSM) illustrated localization as well as the preferential accumulation of PS into the fungal cells. C. neoformans KN99α was more resistant to APDI than CAP59 for all PSs tested. CLSM showed incorporation of MB and RB into the cytoplasm and a preferential uptake in mitochondria. A nuclear accumulation of MB was also observed. Contrarily, pL-ce6 appears accumulated in cell wall and cell membrane and minimal florescence was observed inside the fungal cells. In conclusion, the ability of C. neoformans to form capsule enhances survival following APDI.
NASA Astrophysics Data System (ADS)
Vesey, Roger; Cuneo, M. E.; Hanson Porter, D. L., Jr.; Mehlhorn, T. A.; Ruggles, L. E.; Simpson, W. W.; Hammer, J. H.; Landen, O.
2000-10-01
Capsule radiation symmetry is a crucial issue in the design of the z-pinch driven hohlraum approach to high-yield inertial confinement fusion [1]. Capsule symmetry may be influenced by power imbalance of the two z-pinch x-ray sources, and by hohlraum effects (geometry, time-dependent albedo, wall motion). We have conducted two-dimensional radiation-hydrodynamics calculations to estimate the symmetry sensitivity of the 220 eV beryllium ablator capsule that nominally yields 400 MJ in this concept. These estimates then determine the symmetry requirements to be met by the hohlraum design (for even Legendre modes) and by the top-bottom pinch imbalance and mistiming (for odd Legendre modes). We have used a combination of 2- and 3-D radiosity ("viewfactor"), and 2-D radiation-hydrodynamics calculations to identify hohlraum geometries that meet these symmetry requirements for high-yield, and are testing these models against ongoing Z foam ball symmetry experiments. 1. J. H. Hammer et al., Phys. Plas. 6, 2129 (1999).
Analysis of Fission Products on the AGR-1 Capsule Components
DOE Office of Scientific and Technical Information (OSTI.GOV)
Paul A. Demkowicz; Jason M. Harp; Philip L. Winston
2013-03-01
The components of the AGR-1 irradiation capsules were analyzed to determine the retained inventory of fission products in order to determine the extent of in-pile fission product release from the fuel compacts. This includes analysis of (i) the metal capsule components, (ii) the graphite fuel holders, (iii) the graphite spacers, and (iv) the gas exit lines. The fission products most prevalent in the components were Ag-110m, Cs 134, Cs 137, Eu-154, and Sr 90, and the most common location was the metal capsule components and the graphite fuel holders. Gamma scanning of the graphite fuel holders was also performed tomore » determine spatial distribution of Ag-110m and radiocesium. Silver was released from the fuel components in significant fractions. The total Ag-110m inventory found in the capsules ranged from 1.2×10 2 (Capsule 3) to 3.8×10 1 (Capsule 6). Ag-110m was not distributed evenly in the graphite fuel holders, but tended to concentrate at the axial ends of the graphite holders in Capsules 1 and 6 (located at the top and bottom of the test train) and near the axial center in Capsules 2, 3, and 5 (in the center of the test train). The Ag-110m further tended to be concentrated around fuel stacks 1 and 3, the two stacks facing the ATR reactor core and location of higher burnup, neutron fluence, and temperatures compared with Stack 2. Detailed correlation of silver release with fuel type and irradiation temperatures is problematic at the capsule level due to the large range of temperatures experienced by individual fuel compacts in each capsule. A comprehensive Ag 110m mass balance for the capsules was performed using measured inventories of individual compacts and the inventory on the capsule components. For most capsules, the mass balance was within 11% of the predicted inventory. The Ag-110m release from individual compacts often exhibited a very large range within a particular capsule.« less
Colucci, Philippe; D'Angelo, Pina; Mautone, Giuseppe; Scarsi, Claudia; Ducharme, Murray P
2011-06-01
To assess the pharmacokinetic equivalence of a new soft capsule formulation of levothyroxine versus a marketed reference product and to assess the soft capsule formulated with stricter potency guidelines versus the capsule before the implementation of the new potency rule. Two single-dose randomized two-way crossover pharmacokinetic equivalence studies and one dosage form proportionality single-dose study comparing low, medium, and high strengths of the new formulation. All three studies were performed in a clinical setting. Participants were healthy male and female adult subjects with normal levothyroxine levels. A total of 90 subjects participated in the three studies. Pharmacokinetic parameters were calculated on baseline- adjusted concentrations. The first pharmacokinetic equivalence study compared the levothyroxine sodium soft capsule formulation (Tirosint) with the reference Synthroid tablets and the two products were considered bioequivalent. The dosage form proportionality study compared the 50-, 100-, and 150-μg test capsules strengths dosed at the same level (600 μg) and all three strengths were considered equivalent when given at the same dosage. The last study compared the test capsule used in the first two studies with a new capsule formulation following the new potency guideline (±5%) set forward by the Food and Drug Administration and the two capsules were considered bioequivalent. Doses were well tolerated by subjects in all three studies with no serious adverse events reported. The levothyroxine soft capsule formulated with the stricter new potency guideline set forward by the Food and Drug Administration met equivalence criteria in terms of rate and extent of exposure under fasting conditions to the reference tablet formulation. Clinical doses of the capsule formulation can be given using any combination of the commercialized strengths.
Application of Bio-digestion for Capsule Gelatin-- From the Pharmaceutical Wastes to the Manure
NASA Astrophysics Data System (ADS)
Pan, C.; Huang, S.; Chang, Y.; Wen, J.
2013-12-01
The purpose of this study was to bio-digest the capsule gelatin from the waste of pharmaceutical processes such as cutting and stamping for capsule shells producing. We screened soil bacterial flora for capsule gelatin biolysis, and found the most competent one named Yuntech-7. A 15% (w/w) of capsule gelatin could fully digested by Yuntech-7 for 3 days growth with an N-limited medium in a 37°C incubator. In order to recycle and reuse the gelatin waste, the different percentages of capsule gelatin were co-composted with the vegetable residues to produce manure in an anaerobic fermentation by an extra Yuntech-7 inoculation. After 14 days incubation, we collected the filtrate to examine the contents of N, P, and K. The data shows that the P and K keep the same value by roughly between the blank and the control sets, but the total N values were approximately a 5-fold increase in 20% and a 10-fold increase in 40% of capsule gelatin integrated. We suggested that the capsule gelatin was majorly decomposed by Yuntech-7, because the total N value was no observable change in the capsule gelatin and vegetable residues co-compost with a Yuntech-7-free condition. We also performed some field tests using the capsule gelatin generated liquid manure, and the preliminary test shows the plants got great benefits on culture size and in environmental resistance. In conclusion, the process in bio-digestion of waste capsule gelatin by soil bacteria, Yuntech-7, was produced a valuable manure not only aliment the plants but also complement the soil bacterial populations.
Jenkins, Alexandra L; Morgan, Linda M; Bishop, Jacqueline; Jovanovski, Elena; Vuksan, Vladimir
2014-01-01
Addition of viscous fiber to foods has been shown to significantly reduce postprandial glucose excursions. However, palatability issues and the variability in effectiveness due to different methods of administration in food limits it use. This study explores the effectiveness of a viscous fiber blend (VFB) in lowering postprandial glycemia using different methods of incorporation. Two acute, randomized, controlled studies were undertaken: Study 1: Twelve healthy individuals (mean ± SD, age: 36 ± 13 years, body mass index [BMI]: 27 ± 4 kg/m(2)) consumed 8 different breakfasts. All meals consisted of 50 g of available carbohydrate from white bread (WB) and 10 g margarine. Zero, 1, 2, or 4 g of the VFB was baked into WB or mixed with the margarine. Study 2: Thirteen healthy individuals (mean ± SD, age: 39 ± 17 years, BMI: 25 ± 5 kg/m(2)) consumed 6 test meals, consisting of 50 g of available carbohydrate from WB. Six capsules containing either cornstarch or VFB were taken at 4 different time points during the glucose tolerance test. After obtaining a fasting finger-prick blood sample, volunteers consumed the test meal over a 10-minute period. Additional blood samples were taken at 15, 30, 45, 60, 90, and 120 minutes from the start of the meal. For study 2, an additional fasting sample was obtained at -30 minutes. Study 1: Irrespective of VFB dose, glucose levels were lower at 30 and 45 minutes when VFB was mixed into the margarine compared to the control (p < 0.05). Incremental areas under the curve were significantly lower compared to control when 4 g of VFB was mixed into the margarine. Study 2: There was no effect of the VFB on postprandial glucose levels when administered in capsules. Incorporation of VFB into margarine was more effective in lowering postprandial glycemia than when the VFB was baked into bread and no effect when given in capsules.
Water Landing Characteristics of a Reentry Capsule
NASA Technical Reports Server (NTRS)
1958-01-01
Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.
Water-Landing Characteristics of a Reentry Capsule
NASA Technical Reports Server (NTRS)
McGehee, John R.; Hathaway, Melvin E.; Vaughan, Victor L., Jr.
1959-01-01
Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.
Development of orally disintegrating tablets comprising controlled-release multiparticulate beads
2012-01-01
Melperone is an atypical antipsychotic agent that has shown a wide spectrum of neuroleptic properties, particularly effective in the treatment of senile dementia and Parkinson’s-associated psychosis, and is marketed in Europe as an immediate-release (IR) tablet and syrup. An orally disintegrating tablet (ODT) dosage form would be advantageous for patients who experience difficulty in swallowing large tablets or capsules or those who experience dysphagia. Controlled-release (CR) capsule and ODT formulations containing melperone HCl were developed with target in vitro release profiles suitable for a once-daily dosing regimen. Both dosage forms allow for the convenient production of dose-proportional multiple strengths. Two ODT formulations exhibiting fast and medium release profiles and one medium release profile capsule formulation (each 50 mg) were tested in vivo using IR syrup as the reference. The two medium release formulations were shown to be bioequivalent to each other and are suitable for once-daily dosing. Based on the analytical and organoleptic test results, as well as the blend uniformity and in-process compression data at various compression forces using coated beads produced at one-tenth (1/10) commercial scale, both formulations in the form of CR capsules and CR ODTs have shown suitability for progression into further clinical development. PMID:22356215
Evaluation of friction enhancement through soft polymer micro-patterns in active capsule endoscopy
NASA Astrophysics Data System (ADS)
Buselli, Elisa; Pensabene, Virginia; Castrataro, Piero; Valdastri, Pietro; Menciassi, Arianna; Dario, Paolo
2010-10-01
Capsule endoscopy is an emerging field in medical technology. Despite very promising innovations, some critical issues are yet to be addressed, such as the management and possible exploitation of the friction in the gastrointestinal environment in order to control capsule locomotion more actively. This paper presents the fabrication and testing of bio-inspired polymeric micro-patterns, which are arrays of cylindrical pillars fabricated via soft lithography. The aim of the work is to develop structures that enhance the grip between an artificial device and the intestinal tissue, without injuring the mucosa. In fact, the patterns are intended to be mounted on microfabricated legs of a capsule robot that is able to move actively in the gastrointestinal tract, thus improving the robot's traction ability. The effect of micro-patterned surfaces on the leg-slipping behaviour on colon walls was investigated by considering both different pillar dimensions and the influence of tissue morphology. Several in vitro tests on biological samples demonstrated that micro-patterns of pillars made from a soft polymer with an aspect ratio close to 1 enhanced friction by 41.7% with regard to flat surfaces. This work presents preliminary modelling of the friction and adhesion forces in the gastrointestinal environment and some design guidelines for endoscopic devices.
The presence and influence of posterior capsule tightness on different shoulder problems.
Duzgun, Irem; Turgut, Elif; Çinar-Medeni, Özge; Kafa, Nihan; Tuna, Zeynep; Elbasan, Bulent; Oskay, Deran
2017-01-01
In the literature it has been shown that posterior capsule flexibility is a precursor to shoulder problems. However, no study thus far has shown the influence of the flexibility of posterior capsule in different shoulder pathologies. This study set about to compare the role of posterior capsule tightness in different shoulder problems. One-hundred-twenty-five patients diagnosed with shoulder subacromial impingement syndrome (n= 52), partial rotator cuff tear (n= 31) or frozen shoulder (n= 42) and 30 asymptomatic peers participated in the study. Horizontal adduction was assessed in side-lying position for posterior capsule tightness. Pain was measured via the visual analogue scale and shoulder range of motion and active total elevation was assessed with goniometer. Hand behind the back (HBB) test was assessed the active internal rotation by measuring the distance between T5 and the thumb. It was found that the affected side of the posterior capsules of the patients with subacromial impingement syndrome (p< 0.001), partial rotator cuff tear (p< 0.001) and frozen shoulder (p< 0.001) was stiffer than their healthy side. There were significant differences among groups in the level of tightness in the posterior capsule between the affected and the healthy sides (p< 0.001). All range of motion of the shoulder including HBB test and the posterior capsule tightness of the affected side are found to be correlated (p< 0.05). This study emphasized that the posterior capsule's susceptibility to tightness is most evident in frozen shoulder among different shoulder problems.
Flow visualization around a rotating body in a wind tunnel
NASA Astrophysics Data System (ADS)
Hiraki, K.; Zaitsu, D.; Yanaga, Y.; Kleine, H.
2017-02-01
The rotational behavior of capsule-shaped models is investigated in the transonic wind tunnel of JAXA. A special support is developed to allow the model to rotate around the pitch, yaw and roll axes. This 3-DOF free rotational mounting apparatus achieves the least frictional torque from the support and the instruments. Two types of capsule models are prepared, one is drag type (SPH model) and the other is lift type (HTV-R model). The developed mounting apparatus is used in the wind tunnel tests with these capsule models. In a flow of Mach 0.9, the SPH model exhibits oscillations in pitch and yaw, and it rolls half a turn during the test. Similarly, the HTV-R model exhibits pitch and yaw oscillations in a flow of Mach 0.5. Moreover, it rolls multiple times during the test. In order to investigate the flow field around the capsule, the combined technique of color schlieren and surface tufts is applied. This visualization clearly shows the flow reattachment on the back surface of a capsule, which is suspected to induce the rapid rolling motion.
Application of Background Oriented Schlieren for Altitude Testing of Rocket Engines
NASA Technical Reports Server (NTRS)
Wernet, Mark P.; Stiegemeier, Benjamin R.
2017-01-01
A series of experiments was performed to determine the feasibility of using the Background Oriented Schlieren, BOS, flow visualization technique to image a simulated, small, rocket engine, plume under altitude test conditions. Testing was performed at the NASA Glenn Research Centers Altitude Combustion Stand, ACS, using nitrogen as the exhaust gas simulant. Due to limited optical access to the facility test capsule, all of the hardware required to conduct the BOS were located inside the vacuum chamber. During the test series 26 runs were performed using two different nozzle configurations with pressures in the test capsule around 0.3 psia. No problems were encountered during the test series resulting from the optical hardware being located in the test capsule and acceptable resolution images were captured. The test campaign demonstrated the ability of using the BOS technique for small, rocket engine, plume flow visualization during altitude testing.
Khrouf, Mohamed; Slimani, Soufiene; Khrouf, Myriam Razgallah; Braham, Marouen; Bouyahia, Maha; Berjeb, Khadija Kacem; Chaabane, Hanene Elloumi; Merdassi, Ghaya; Kaffel, Aida Zahaf; Zhioua, Amel; Zhioua, Fethi
2016-01-01
BACKGROUND In IVF, Luteal phase support is usually performed using vaginal progesterone. A part of patients using this route reports being uncomfortable with this route. We tried to study whether the rectal route could be an effective alternative and associated with less discomfort. PATIENTS AND METHODS A prospective randomized controlled study. All patient were eligible for IVF treatment for infertility. After oocyte pickup, 186 patients were allocated to one the following protocols for luteal phase support: (i) rectal pessaries group: natural progesterone pessaries administered rectally 200 mg three times a day, (ii) vaginal pessaries group: natural progesterone pessaries administered vaginally 200 mg three times a day), and (iii) vaginal capsules group: natural micronized progesterone capsules administered vaginally 200 mg three times a day. On the day of pregnancy test, patients were asked to fill in a questionnaire conducted by an investigator in order to assess the tolerability and side effects of the LPS treatment taken. The primary endpoint was the occurrence of perineal irritation. RESULTS Fifty eight patients were assigned to the rectal pessaries group, 68 patients to the vaginal pessaries group, and 60 patients to the vaginal capsules group. All patients adhered to their allocated treatment. Implantation and clinical pregnancy rates per transfer did not differ between the three groups. Perineal irritation, which was our primary endpoint, was the same for all the three groups (respectively 1.7 % versus 5.9 % versus 11.7%). Regarding the other side effects, more patients experienced constipation and flatulence with the rectal route, whereas more patients reported vaginal discharge in the vaginal capsules group. CONCLUSION Rectal administration for luteal phase support is effective and well accepted alternative to vaginal route. PMID:28096703
Khrouf, Mohamed; Slimani, Soufiene; Khrouf, Myriam Razgallah; Braham, Marouen; Bouyahia, Maha; Berjeb, Khadija Kacem; Chaabane, Hanene Elloumi; Merdassi, Ghaya; Kaffel, Aida Zahaf; Zhioua, Amel; Zhioua, Fethi
2016-01-01
In IVF, Luteal phase support is usually performed using vaginal progesterone. A part of patients using this route reports being uncomfortable with this route. We tried to study whether the rectal route could be an effective alternative and associated with less discomfort. A prospective randomized controlled study. All patient were eligible for IVF treatment for infertility. After oocyte pickup, 186 patients were allocated to one the following protocols for luteal phase support: (i) rectal pessaries group: natural progesterone pessaries administered rectally 200 mg three times a day, (ii) vaginal pessaries group: natural progesterone pessaries administered vaginally 200 mg three times a day), and (iii) vaginal capsules group: natural micronized progesterone capsules administered vaginally 200 mg three times a day. On the day of pregnancy test, patients were asked to fill in a questionnaire conducted by an investigator in order to assess the tolerability and side effects of the LPS treatment taken. The primary endpoint was the occurrence of perineal irritation. Fifty eight patients were assigned to the rectal pessaries group, 68 patients to the vaginal pessaries group, and 60 patients to the vaginal capsules group. All patients adhered to their allocated treatment. Implantation and clinical pregnancy rates per transfer did not differ between the three groups. Perineal irritation, which was our primary endpoint, was the same for all the three groups (respectively 1.7 % versus 5.9 % versus 11.7%). Regarding the other side effects, more patients experienced constipation and flatulence with the rectal route, whereas more patients reported vaginal discharge in the vaginal capsules group. Rectal administration for luteal phase support is effective and well accepted alternative to vaginal route.
NASA Technical Reports Server (NTRS)
Norgard, John D.
2012-01-01
For future NASA Manned Space Exploration of the Moon and Mars, a blunt body capsule, called the Orion Crew Exploration Vehicle (CEV), composed of a Crew Module (CM) and a Service Module (SM), with a parachute decent assembly is planned for reentry back to Earth. A Capsule Parachute Assembly System (CPAS) is being developed for preliminary prototype parachute drop tests at the Yuma Proving Ground (YPG) to simulate high-speed reentry to Earth from beyond Low-Earth-Orbit (LEO) and to provide measurements of position, velocity, acceleration, attitude, temperature, pressure, humidity, and parachute loads. The primary and secondary (backup) avionics systems on CPAS also provide mission critical firing events to deploy, reef, and release the parachutes in three stages (extraction, drogues, mains) using mortars and pressure cartridge assemblies. In addition, a Mid-Air Delivery System (MDS) is used to separate the capsule from the sled that is used to eject the capsule from the back of the drop plane. Also, high-speed and high-definition cameras in a Video Camera System (VCS) are used to film the drop plane extraction and parachute landing events. Intentional and unintentional radiation emitted from and received by antennas and electronic devices on/in the CEV capsule, the MDS sled, and the VCS system are being tested for radiated emissions/immunity (susceptibility) (RE/RS). To verify Electromagnetic Compatibility (EMC) of the Orion capsule, Electromagnetic Interference (EMI) measurements are being made inside a semi-anechoic chamber at NASA/JSC on the components of the CPAS system. Measurements are made at 1m from the components-under-test (CUT). In addition, EMI measurements of the integrated CEV system are being made inside a hanger at YPG. These measurements are made in a complete circle, at 30? angles or less, around the Orion Capsule, the spacecraft system under-test (SUT). Near-field B-Dot probe measurements on the surface of the Orion capsule are being extrapolated outward to the 1m standard distance for comparison to the MIL-STD radiated emissions limit, and far-field hybrid antenna measurements at 3m are being extrapolated inward to the 1m distance for similar comparisons.
Entry Trajectory Issues for the Stardust Sample Return Capsule
NASA Technical Reports Server (NTRS)
Desai, Prasun N.; Mitcheltree, Robert A.; Cheatwood, F. McNeil
1999-01-01
The Stardust mission was successfully launched on February 7, 1999. It will be the first mission to return samples from a comet. The sample return capsule, which is passively controlled during the fastest Earth entry ever, will land by parachute in Utah. The present study describes the analysis of the entry, descent, and landing of the returning sample capsule utilizing the final, launch configuration capsule mass properties. The effects of two aerodynamic instabilities are revealed (one in the high altitude free molecular regime and the other in the transonic/subsonic flow regime). These instabilities could lead to unacceptably large excursions in the angle-of-attack near peak heating and main parachute deployment, respectively. To reduce the excursions resulting from the high altitude instability, the entry spin rate of the capsule is increased. To stabilize the excursions from the transonic/subsonic instability, a drogue chute with deployment triggered by a gravity-switch and timer is added prior to main parachute deployment. A Monte Carlo dispersion analysis of the modified entry (from which the impact of off-nominal conditions during the entry is ascertained) predicts that the capsule attitude excursions near peak heating and drogue chute deployment are within Stardust mission limits. Additionally, the size of the resulting 3-sigma landing ellipse is 60.8 km in downrange by 19.9 km in crossrange, which is within the Utah Test and Training Range boundaries.
Mou, Xiaodun; Lennartz, Michelle R; Loegering, Daniel J; Stenken, Julie A
2011-01-01
Modulation of the foreign body reaction is considered to be an important step toward creation of implanted sensors with reliable long-term performance. In this work, microdialysis probes were implanted into the subcutaneous space of Sprague-Dawley rats. The probe performance was evaluated by comparing collected endogenous glucose concentrations with internal standard calibration (2-deoxyglucose, antipyrine, and vitamin B12). Probes were tested until failure, which for this work was defined as loss of fluid flow. In order to determine the effect of fibrous capsule formation on probe function, monocyte chemoattractant protein-1/CC chemokine ligand 2 (MCP-1/CCL2) was delivered locally via the probe to increase capsule thickness and dexamethasone 21-phosphate was delivered to reduce capsule thickness. Probes delivering MCP-1 had a capsule that was twice the thickness (500–600 μm) of control probes (200–225 μm) and typically failed 2 days earlier than control probes. Probes delivering dexamethasone 21-phosphate had more fragile capsules and the probes typically failed 2 days later than controls. Unexpectedly, extraction efficiency and collected glucose concentrations exhibited minor differences between groups. This is an interesting result in that the foreign body capsule formation was related to the duration of probe function but did not consistently relate to probe calibration. PMID:21722577
Metabolic and exercise endurance effects of coffee and caffeine ingestion.
Graham, T E; Hibbert, E; Sathasivam, P
1998-09-01
Caffeine (Caf) ingestion increases plasma epinephrine (Epi) and exercise endurance; these results are frequently transferred to coffee (Cof) consumption. We examined the impact of ingestion of the same dose of Caf in Cof or in water. Nine healthy, fit, young adults performed five trials after ingesting (double blind) either a capsule (Caf or placebo) with water or Cof (decaffeinated Cof, decaffeinated with Caf added, or regular Cof). In all three Caf trials, the Caf dose was 4.45 mg/kg body wt and the volume of liquid was 7.15 ml/kg. After 1 h of rest, the subject ran at 85% of maximal O2 consumption until voluntary exhaustion (approximately 32 min in the placebo and decaffeinated Cof tests). In the three Caf trials, the plasma Caf and paraxanthine concentrations were very similar. After 1 h of rest, the plasma Epi was increased (P < 0.05) by Caf ingestion, but the increase was greater (P < 0.05) with Caf capsules than with Cof. During the exercise there were no differences in Epi among the three Caf trials, and the Epi values were all greater (P < 0.05) than in the other tests. Endurance was only increased (P < 0. 05) in the Caf capsule trial; there were no differences among the other four tests. One cannot extrapolate the effects of Caf to Cof; there must be a component(s) of Cof that moderates the actions of Caf.
Qasem, Ahmad; Safavikhasraghi, Mitra; Naser, Saleh A
2016-01-01
Most recently we reported that RHB‑104 triple antibiotics combination in culture is bactericidal and should be effective for treatment of Crohn's disease (CD)-associated with Mycobacterium avium subspecies paratuberculosis (MAP) (Alcedo et al. in Gut Pathog 14:32, 2016). The combination exhibited unique synergistic antimicrobial growth activity. The proprietary RHB-104 capsule formulation contains active ingredients (63.3 % Clarithromycin (CLA), 6.7 % Clofazimine (CLO) and 30 % Rifabutin (RIF)). In our earlier study, we could not dissolve the proprietary RHB-104 capsule formulation in one compatible solvent. Consequently, we re-created RHB-104 analog by adding appropriate concentrations of each of the three antibiotics into the cultures. The Minimum inhibitory concentration (MIC) for RHB-104 analog, CLA, CLO, RIF, CLA-CLO, CLA-RIF, CLO-RIF and their individual solvents were reported earlier (Alcedo et al. in Gut Pathog 14:32, 2016). In this study, we succeeded in dissolving the proprietary RHB-104 capsule formulation in a single proprietary solvent. This study is designed to compare of the MIC the proprietary RHB-104 capsule formulation to RHB-104 analog against MAP and other microorganisms. BD Bactec™ MGIT™ Para-TB medium (Sparks, MD) system was used to determine the MIC of the proprietary RHB-104 capsule formulation and RHB-104 analog and their solvents against MAP and several other microorganisms. The final concentration of solvents used to dissolve all the drugs were ≤0.5 % (v/v). The MIC for the RHB-104 proprietary solvent against MAP was consistent against all microorganisms tested in the study at 12.5 % (v/v). The MIC for the proprietary RHB-104 capsule formulation was similar to RHB-104 analog against several MAP clinical strains with MIC ≤ 0.2 μg/mL. The MIC for the proprietary RHB-104 capsule formulation was at 2.0 μg/mL against MAP strain MS 137 and M. avium strain JF7 compared to 4.0 ug/mL for RHB-104 analog. Similarly, the MIC of RHB-104 formulation capsule was significantly lower than RHB-104 analog against M. tuberculosis HR237, M. fortuitism subspecies fortuitum, M. smegmatis ATCC 27199, Staphylococcus aureus ATCC 25923 and Listeria monocytogenes ATCC 19112. The data demonstrated that the proprietary RHB-104 capsule formulation is more potent in culture against Mycobacteria and other microorganisms especially those with MIC >0.2. Formulation of multi-drugs in a single capsule results in potent synergistic anti-microbial activity far exceeds treatment the culture with multi-individually dissolved drugs. RHB-104 capsule formulation should be more effective to eradicate MAP infection in patients with CD. The study provides evidence that combining weak antibiotics in one formulation might be the new silver bullet to combat bacteria.
Performance of acidified 14C-urea capsule breath test during pantoprazole and ranitidine treatment.
Oztürk, Emel; Yeşilova, Zeki; Ilgan, Seyfettin; Ozgüven, Mehmet; Dağalp, Kemal
2009-07-01
Urea breath test (UBT) results could be false negative in patients taking antisecretory drugs. This effect would be prevented by citric acid administration during UBT. We prospectively investigated whether acidified 14C-urea capsule prevents false negative UBT results in patients taking antisecretory drugs and show interference with the duration of medications. Sixty Helicobacter pylori positive patients were included. Pantoprazole (40 mg/day) was given to 27 patients for 28 days and ranitidine (300 mg. o.d.) to 33 patients for 60 days. Urea breath tests were repeated on days 14 and 28 in both groups and on day 60 in the ranitidine group. The baseline mean breath counts of two groups did not show any significant difference. Pantoprazole led to a significant decrease in mean breath counts on day 14 (P < 0.005). Six of 27 and 3 of 25 patients taking pantoprazole developed negative or equivocal UBT results on days 14 and 28, respectively. Two of 32, 2 of 32 and 3 of 21 patients taking ranitidine developed negative or equivocal UBT results on days 14, 28 and 60, respectively. The use of acidified 14C-urea capsule did not prevent false negative UBT results in patients taking pantoprazole and ranitidine, and the duration of medication does not affect the test results.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jubin, Robert Thomas; Bruffey, Stephanie H.
Legacy samples composed of 85Kr encapsulated in solid zeolite 5A material and five small metal tubes containing a mixture of the zeolite combined with a glass matrix resulting from hot isostatic pressing have been preserved. The samples were a result of krypton R&D encapsulation efforts in the late 1970s performed at the Idaho Chemical Processing Plant. These samples were shipped to Oak Ridge National Laboratory (ORNL) in mid-FY 2014. Upon receipt the outer shipping package was opened, and the inner package, removed and placed in a radiological hood. The individual capsules were double bagged as they were removed from themore » inner shipping pig and placed into individual glass sample bottles for further analysis. The five capsules were then x-ray imaged. Capsules 1 and 4 appear intact and to contain an amorphous mass within the capsules. Capsule 2 clearly shows the saw marks on the capsule and a quantity of loose pellet or bead-like material remaining in the capsule. Capsule 3 shows similar bead-like material within the intact capsule. Capsule 5 had been opened at an undetermined time in the past. The end of this capsule appears to have been cut off, and there are additional saw marks on the side of the capsule. X-ray tomography allowed the capsules to be viewed along the three axes. Of most interest was determining whether there was any residual material in the closed end of Capsule 5. The images confirmed the presence of residual material within this capsule. The material appears to be compacted but still retains some of the bead-like morphology. Based on the nondestructive analysis (NDA) results, a proposed path forward was formulated to advance this effort toward the original goals of understanding the effects of extended storage on the waste form and package. Based on the initial NDA and the fact that there are at least two breached samples, it was proposed that exploratory tests be conducted with the breached specimens before opening the three intact capsules. Portions of these would be analyzed to determine the fraction of krypton/xenon remaining in the matrix and the amount of rubidium remaining in the matrix. The inner surface of the breached capsules would be examined for corrosion. The materials contained in Capsules 2 and 5 have been examined. There appears to be a relatively uniform distribution of Kr and Rb throughout the pellets examined. The chemical composition of the pellets appears to be consistent with 5A molecular sieves. The material contained within Capsule 5 showed ~1 at. % lead. The origin of the Pb is currently indeterminate. X-ray diffraction analysis shows a significant shift from the 5A structure, most likely due to the Kr encapsulation / sintering process that occurred when the samples were made. The capsule walls were also examined and showed extensive corrosion throughout. Elemental mapping of the capsule material appeared consistent with carbon steel, while the weld material appeared consistent with a stainless steel. The interior surface of the capsule appeared to have a layer of material containing Al, Si, and Ca similar to the 5A molecular sieve. Analysis for Rb within the corrosion sites was inconclusive.« less
Using Numerical Modeling to Simulate Space Capsule Ground Landings
NASA Technical Reports Server (NTRS)
Heymsfield, Ernie; Fasanella, Edwin L.
2009-01-01
Experimental work is being conducted at the National Aeronautics and Space Administration s (NASA) Langley Research Center (LaRC) to investigate ground landing capabilities of the Orion crew exploration vehicle (CEV). The Orion capsule is NASA s replacement for the Space Shuttle. The Orion capsule will service the International Space Station and be used for future space missions to the Moon and to Mars. To evaluate the feasibility of Orion ground landings, a series of capsule impact tests are being performed at the NASA Langley Landing and Impact Research Facility (LandIR). The experimental results derived at LandIR provide means to validate and calibrate nonlinear dynamic finite element models, which are also being developed during this study. Because of the high cost and time involvement intrinsic to full-scale testing, numerical simulations are favored over experimental work. Subsequent to a numerical model validated by actual test responses, impact simulations will be conducted to study multiple impact scenarios not practical to test. Twenty-one swing tests using the LandIR gantry were conducted during the June 07 through October 07 time period to evaluate the Orion s impact response. Results for two capsule initial pitch angles, 0deg and -15deg , along with their computer simulations using LS-DYNA are presented in this article. A soil-vehicle friction coefficient of 0.45 was determined by comparing the test stopping distance with computer simulations. In addition, soil modeling accuracy is presented by comparing vertical penetrometer impact tests with computer simulations for the soil model used during the swing tests.
Project Mercury Escape Tower Rockets Tests
1960-04-21
A Mercury capsule is mounted inside the Altitude Wind Tunnel for a test of its escape tower rockets at the National Aeronautics and Space Administration (NASA) Lewis Research Center. In October 1959 NASA’s Space Task Group allocated several Project Mercury assignments to Lewis. The Altitude Wind Tunnel was quickly modified so that its 51-foot diameter western leg could be used as a test chamber. The final round of tests in the Altitude Wind Tunnel sought to determine if the smoke plume from the capsule’s escape tower rockets would shroud or compromise the spacecraft. The escape tower, a 10-foot steel rig with three small rockets, was attached to the nose of the Mercury capsule. It could be used to jettison the astronaut and capsule to safety in the event of a launch vehicle malfunction on the pad or at any point prior to separation from the booster. Once actuated, the escape rockets would fire, and the capsule would be ejected away from the booster. After the capsule reached its apex of about 2,500 feet, the tower, heatshield, retropackage, and antenna would be ejected and a drogue parachute would be released. Flight tests of the escape system were performed at Wallops Island as part of the series of Little Joe launches. Although the escape rockets fired prematurely on Little Joe’s first attempt in August 1959, the January 1960 follow-up was successful.
Faerber, Julia; Cummins, Gerard; Pavuluri, Sumanth Kumar; Record, Paul; Rodriguez, Adrian R Ayastuy; Lay, Holly S; McPhillips, Rachael; Cox, Benjamin F; Connor, Ciaran; Gregson, Rachael; Clutton, Richard Eddie; Khan, Sadeque Reza; Cochran, Sandy; Desmulliez, Marc P Y
2018-02-01
This paper describes the design, fabrication, packaging, and performance characterization of a conformal helix antenna created on the outside of a capsule endoscope designed to operate at a carrier frequency of 433 MHz within human tissue. Wireless data transfer was established between the integrated capsule system and an external receiver. The telemetry system was tested within a tissue phantom and in vivo porcine models. Two different types of transmission modes were tested. The first mode, replicating normal operating conditions, used data packets at a steady power level of 0 dBm, while the capsule was being withdrawn at a steady rate from the small intestine. The second mode, replicating the worst-case clinical scenario of capsule retention within the small bowel, sent data with stepwise increasing power levels of -10, 0, 6, and 10 dBm, with the capsule fixed in position. The temperature of the tissue surrounding the external antenna was monitored at all times using thermistors embedded within the capsule shell to observe potential safety issues. The recorded data showed, for both modes of operation, a low error transmission of 10 -3 packet error rate and 10 -5 bit error rate and no temperature increase of the tissue according to IEEE standards.
Analytical model for effects of capsule shape on the healing efficiency in self-healing materials
Li, Songpeng; Chen, Huisu
2017-01-01
The fundamental requirement for the autonomous capsule-based self-healing process to work is that cracks need to reach the capsules and break them such that the healing agent can be released. Ignoring all other aspects, the amount of healing agents released into the crack is essential to obtain a good healing. Meanwhile, from the perspective of the capsule shapes, spherical or elongated capsules (hollow tubes/fibres) are the main morphologies used in capsule-based self-healing materials. The focus of this contribution is the description of the effects of capsule shape on the efficiency of healing agent released in capsule-based self-healing material within the framework of the theory of geometrical probability and integral geometry. Analytical models are developed to characterize the amount of healing agent released per crack area from capsules for an arbitrary crack intersecting with capsules of various shapes in a virtual capsule-based self-healing material. The average crack opening distance is chosen to be a key parameter in defining the healing potential of individual cracks in the models. Furthermore, the accuracy of the developed models was verified by comparison to the data from a published numerical simulation study. PMID:29095862
RERTR-12 Insertion 2 Irradiation Summary Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. M. Perez; G. S. Chang; D. M. Wachs
2012-09-01
The Reduced Enrichment for Research and Test Reactor (RERTR) experiment RERTR-12 was designed to provide comprehensive information on the performance of uranium-molybdenum (U-Mo) based monolithic fuels for research reactor applications.1 RERTR-12 insertion 2 includes the capsules irradiated during the last three irradiation cycles. These capsules include Z, Y1, Y2 and Y3 type capsules. The following report summarizes the life of the RERTR-12 insertion 2 experiment through end of irradiation, including as-run neutronic analysis results, thermal analysis results and hydraulic testing results.
Swallowable capsule with air channel for improved image-guided cancer detection in the esophagus
NASA Astrophysics Data System (ADS)
Seibel, Eric J.; Melville, C. David; Lung, Jonathan K. C.; Babchanik, Alexander P.; Lee, Cameron M.; Johnston, Richard S.; Dominitz, Jason A.
2009-02-01
A new type of endoscope has been developed and tested in the human esophagus, a tethered-capsule endoscope (TCE) that requires no sedation for oral ingestion and esophageal inspection. The TCE uses scanned red, green, and blue laser light to image the upper digestive tract using a swallowable capsule of 6.4mm in diameter and 18mm in length on a 1.4mm diameter tether. The TCE has been modified for image-guided interventions in the lower esophagus, specifically for more effective detection and measurement of the extent of Barrett's esophagus, a precursor to esophageal cancer. Three modifications have been tested in vivo: (1) weighting the capsule so it is negatively buoyant in water, (2) increasing the frame rate of 500-line images to 30 Hz (video rate), and (3) adding a 1.0mm inner diameter working channel alongside the tether for distending the lower esophagus with air pressure during endoscopy. All three modifications proved effective for more clearly visualizing the lower esophagus in the first few human subjects. The air channel was especially useful because it did not change tolerability in the first subject for unsedated endoscopy and the air easily removed bubbles obscuring tissue from the field of view. The air provided a non-invasive intervention by stimulating the mechanosensor of the lower esophageal sphincter at the precise time that the TCE was positioned for most informative imaging. All three TCE modifications proved successful for improved visualization of esophageal pathology, such as suspected Barrett's esophagus, without the use of sedation.
Kołodziejczyk, Michał Krzysztof; Kołodziejska, Justyna; Zgoda, Marian Mikołaj
2012-01-01
Diclofenac and its sodium salt is one of the best-known and popular therapeutic agents from the group of NSAIDs used in medicine in many various pharmaceutical forms. Therapeutic products containing diclofenac sodium salt in doses of 100 mg and 75 mg with a qualitatively and quantitatively diversified share of excipients and a variable dosage form of the drug (solid capsules, tablets with modified release) were subjected to technological and pharmaceutical analysis. The effect of solid formulation components of polymer character making the core and the coating of the pharmaceutical form of therapeutic products on the disintegration time and pharmaceutical availability in pharmacopoeial receptor fluids was estimated. Market therapeutic products with diclofenac sodium in doses of 75 mg and 100 mg, technological analysis of the drug dosage form was conducted, disintegration time of solid oral dosage forms of the drug with diclofenac sodium salt was examined and research on pharmaceutical availability of diclofenac sodium salt from tested therapeutic products was conducted using the acid phase and the buffer phase according to the FP standards for delayed release enteral dosage forms. The experimental data was supplemented with the statistical analysis. There are three formulations in the form of solid capsules and one formulation in the form of a coated tablet. All therapeutic products bear features of a dosage form of modified release of diclofenac sodium salt, frequently of a delayed release formula in the duodenum or the small intestine with regard to the limitation of typical undesirable effects after taking NSAIDs. Considerable diversity between solid capsules and the tablet with modified release during disintegration or hydration and swelling has been observed. In the environment of a receptor fluid--purified water (pH = 7) the capsule Dicloberl retard disintegrates at the fastest rate in 5,49 minutes, and then in the order: DicloDuo 75 mg--8,13 minutes and Olfen 100 SR--11,27 minutes. The hydration degree of gelatin walls of capsules depends on the pH of the receptor fluid. The availability of diclofenac sodium salt in given receptor fluids confirms the fact of significant connection of clinical effectiveness of the tested pharmaceutical forms with the activity of hydrogen ions (pH) of the environment in which there are therapeutic products, and excipients used for making the pharmaceutical phase. Tested therapeutic products with diclofenac sodium salt are differentiated by the type of a dosage form. Dicloberl retard contains the minimally indispensable number of simple, commonly used excipients. The research on the disintegration time may only be related to the products Dicloberl retard, Olfen 100 SR and DicloDuo 75 mg treating it as the time of deformation and disintegration of a capsule. In all three types of receptor fluids, the capsule Dicloberl retard has the fastest disintegration rate. The "acid phase" demonstrated stability of the products with a slight dissolution of diclofenac sodium salt on the level 1,3-4,18% of the Q release coefficient. In the environment of artificial intestinal juice, Dicloberl retard is more effective releasing larger amounts of diclofenac sodium salt during 4 hours of exposition (differences from 10% to 14% of the Q release coefficient).
NASA Astrophysics Data System (ADS)
Do, Dukho; Kang, DongKyun; Tabatabaei, Nima; Grant, Catriona N.; Nishioka, Norman S.; Rosenberg, Mireille; Hesterberg, Paul E.; Yuan, Qian; Garber, John J.; Katz, Aubrey J.; Shreffler, Wayne G.; Tearney, Guillermo J.
2017-02-01
Eosinophilic Esophagitis (EoE) is an inflammatory disease caused by inhaled or ingested food allergies, and characterized by the infiltration of eosinophils in the esophagus. The gold standard for diagnosing EoE is to conduct endoscopy and obtain multiple biopsy specimens from different portions of the esophagus; an exam is considered positive if more than 15 eosinophils per high power field (HPF) in any of the biopsies. This method of diagnosis is problematic because endoscopic biopsy is expensive and poorly tolerated and the esophageal eosinophil burden needs to be monitored frequently during the course of the disease. Spectrally encoded confocal microscopy (SECM) is a high-speed confocal microscopy technology that can visualize individual eosinophils in large microscopic images of the human esophagus, equivalent to more than 30,000 HPF. Previously, we have demonstrated that tethered capsule SECM can be conducted in unsedated subjects with diagnosed EoE. However, speckle noise and the relatively low resolution in images obtained with the first capsule prototypes made it challenging to distinguish eosinophils from other cells. In this work, we present a next-generation tethered SECM capsule, which has been modified to significantly improve image quality. First, we substituted the single mode fiber with a dual-clad fiber to reduce speckle noise. A gradient-index multimode fiber was fusion spliced at the tip of the dual-clad fiber to increase the effective numerical aperture of the fiber from 0.09 to 0.15, expanding the beam more rapidly to increase the illumination aperture at the objective. These modifications enabled the new SECM capsule to achieve a lateral resolution of 1.8 µm and an axial resolution of 16.1 µm, which substantially improves the capacity of this probe to visualize cellular features in human tissue. The total size of the SECM capsule remained 6.75 mm in diameter and 31 mm in length. We are now in the process of testing this new SECM capsule in humans. Early results using this new SECM capsule suggest that this technology has the potential to be an effective tool for the diagnosis of EoE.
Palea, Ovidiu; Andar, Haroon M; Lugo, Ramon; Granville, Michelle; Jacobson, Robert E
2018-03-14
Radiofrequency cervical rhizotomy has been shown to be effective for the relief of chronic neck pain, whether it be due to soft tissue injury, cervical spondylosis, or post-cervical spine surgery. The target and technique have traditionally been taught using an oblique approach to the anterior lateral capsule of the cervical facet joint. The goal is to position the electrode at the proximal location of the recurrent branch after it leaves the exiting nerve root and loops back to the cervical facet joint. The standard oblique approach to the recurrent nerve requires the testing of both motor and sensory components to verify the correct position and ensure safety so as to not damage the slightly more anterior nerve root. Bilateral lesions require the repositioning of the patient's neck. Poorly positioned electrodes can also pass anteriorly and contact the nerve root or vertebral artery. The direct posterior approach presented allows electrode positioning over a broader expanse of the facet joint without risk to the nerve root or vertebral artery. Over a four-year period, direct posterior radiofrequency ablation was performed under fluoroscopic guidance at multiple levels without neuro-stimulation testing with zero procedural neurologic events even as high as the C2 spinal segment. The direct posterior approach allows either unipolar or bipolar lesioning at multiple levels. Making a radiofrequency lesion along the larger posterior area of the facet capsule is as effective as the traditional target point closer to the nerve root but technically easier, allowing bilateral access and safety. The article will review the anatomy and innervation of the cervical facet joint and capsule, showing the diffuse nerve supply extending into the capsule of the facet joint that is more extensive than the recurrent medial sensory branches that have been the focus of radiofrequency lesioning.
Palea, Ovidiu; Andar, Haroon M; Lugo, Ramon; Jacobson, Robert E
2018-01-01
Radiofrequency cervical rhizotomy has been shown to be effective for the relief of chronic neck pain, whether it be due to soft tissue injury, cervical spondylosis, or post-cervical spine surgery. The target and technique have traditionally been taught using an oblique approach to the anterior lateral capsule of the cervical facet joint. The goal is to position the electrode at the proximal location of the recurrent branch after it leaves the exiting nerve root and loops back to the cervical facet joint. The standard oblique approach to the recurrent nerve requires the testing of both motor and sensory components to verify the correct position and ensure safety so as to not damage the slightly more anterior nerve root. Bilateral lesions require the repositioning of the patient's neck. Poorly positioned electrodes can also pass anteriorly and contact the nerve root or vertebral artery. The direct posterior approach presented allows electrode positioning over a broader expanse of the facet joint without risk to the nerve root or vertebral artery. Over a four-year period, direct posterior radiofrequency ablation was performed under fluoroscopic guidance at multiple levels without neuro-stimulation testing with zero procedural neurologic events even as high as the C2 spinal segment. The direct posterior approach allows either unipolar or bipolar lesioning at multiple levels. Making a radiofrequency lesion along the larger posterior area of the facet capsule is as effective as the traditional target point closer to the nerve root but technically easier, allowing bilateral access and safety. The article will review the anatomy and innervation of the cervical facet joint and capsule, showing the diffuse nerve supply extending into the capsule of the facet joint that is more extensive than the recurrent medial sensory branches that have been the focus of radiofrequency lesioning. PMID:29765790
Purohit, Hitesh S; Trasi, Niraj S; Sun, Dajun D; Chow, Edwin C Y; Wen, Hong; Zhang, Xinyuan; Gao, Yi; Taylor, Lynne S
2018-05-01
Delivering a drug in amorphous form in a formulated product is a strategy used to enhance the apparent solubility of a drug substance and its oral bioavailability. Drug crystallization in such products may occur during the manufacturing process or on storage, reducing the solubility advantage of the amorphous drug. However, the impact of partial drug crystallization in the drug product on the resulting bioavailability and pharmacokinetics is unknown. In this study, dissolution testing of commercial tacrolimus capsules (which are formulated to contain amorphous drug), both fresh and those containing different amounts of crystalline drug, was conducted using both United States Pharmacopeia and noncompendial dissolution tests with different dissolution media and volumes. A physiologically based pharmacokinetic (PBPK) absorption model was developed to predict the impact of crystallinity extent on the oral absorption of the products and to evaluate the discriminatory ability of the different dissolution methods. Virtual bioequivalence simulations between partially crystallized tacrolimus capsules versus fresh Prograf or generic tacrolimus capsules were performed using the PBPK model and in vitro dissolution data of the various fresh and partially crystallized capsules under United States Pharmacopeia and noncompendial dissolution conditions. The results suggest that compendial dissolution tests may not be sufficiently discriminatory with respect to the presence of crystallinity in an amorphous formulation. Nonsink dissolution tests using lower dissolution volumes generate more discriminatory profiles that predict different pharmacokinetics of tacrolimus capsules containing different extents of drug crystallinity. In conclusion, the PBPK modeling approach can be used to assess the impact of partial drug crystallinity in the formulated product and to guide the development of appropriate dissolution methods. Copyright © 2018 American Pharmacists Association®. All rights reserved.
Sarı, Ahmet; Alkan, Cemil; Biçer, Alper
2016-05-01
In this study, PMMA/heneicosane (C21) and PMMA/octacosane (C28) micro-nano capsules were fabricated via emulsion polymerisation method. The chemical structures of the fabricated capsules were verified with the FT-IR spectroscopy analysis. The results of POM, SEM and PSD analysis indicated that most of the capsules were consisted of micro/nano-sized spheres with compact surface. The DSC measurements showed that the capsules had melting temperature in the range of about 39-60 °C and latent heat energy storage capacity in the range of about 138-152 J/g. The results of TGA showed that sublimit temperature values regarding the first degradation steps of both capsules were quite over the phase change or working temperatures of encapsulated paraffins. The thermal cycling test exhibited that the capsules had good thermal reliability and chemical stability. Additionally, the prepared capsules had reasonably high thermal conductivity.
Protective Role of the Capsule and Impact of Serotype 4 Switching on Streptococcus mitis
Rukke, Håkon V.; Kalluru, Raja Sab; Repnik, Urska; Gerlini, Alice; José, Ricardo J.; Periselneris, Jimstan; Marshall, Helina; Griffiths, Gareth; Oggioni, Marco Rinaldo; Brown, Jeremy S.
2014-01-01
The polysaccharide capsule surrounding Streptococcus pneumoniae is essential for virulence. Recently, Streptococcus mitis, a human commensal and a close relative of S. pneumoniae, was also shown to have a capsule. In this study, the S. mitis type strain switched capsule by acquisition of the serotype 4 capsule locus of S. pneumoniae TIGR4, following induction of competence for natural transformation. Comparison of the wild type with the capsule-switching mutant and with a capsule deletion mutant showed that the capsule protected S. mitis against phagocytosis by RAW 264.7 macrophages. This effect was enhanced in the S. mitis strain expressing the S. pneumoniae capsule, which showed, in addition, increased resistance against early clearance in a mouse model of lung infection. Expression of both capsules also favored survival in human blood, and the effect was again more pronounced for the capsule-switching mutant. S. mitis survival in horse blood or in a mouse model of bacteremia was not significantly different between the wild type and the mutant strains. In all models, S. pneumoniae TIGR4 showed higher rates of survival than the S. mitis type strain or the capsule-switching mutant, except in the lung model, in which significant differences between S. pneumoniae TIGR4 and the capsule-switching mutant were not observed. Thus, we identified conditions that showed a protective function for the capsule in S. mitis. Under such conditions, S. mitis resistance to clearance could be enhanced by capsule switching to serotype 4, but it was enhanced to levels lower than those for the virulent strain S. pneumoniae TIGR4. PMID:24958712
Asymptomatic bronchial aspiration and prolonged retention of a capsule endoscope: a case report.
Pezzoli, Alessandro; Fusetti, Nadia; Carella, Alessandra; Gullini, Sergio
2011-08-02
Capsule endoscopy has, over the last few years, become a first-line test to visualize the mucosa of the small intestine. This technique is generally considered safe and does not cause discomfort for patients. However, although patients may have difficulty in swallowing the capsule, bronchial aspiration of a capsule endoscope is a very rare complication. We report the case of an 82-year-old man who experienced prolonged bronchial aspiration of a capsule endoscope without relevant symptoms, followed by a spontaneous return of the capsule to the gastrointestinal tract. An 82-year-old Caucasian man was referred to our unit from another local hospital to undergo capsule endoscopy. He swallowed the capsule without any apparent difficulties and did not show any overt symptoms. The following day, when we reviewed the capsule endoscopy images, we realized that the capsule was in the bronchial system and remained there for the duration of the study. An urgent X-ray of the chest confirmed the presence of the capsule in the left side of the bronchopulmonary tree. Two days later a repeat chest X-ray showed the capsule in the right bronchus. After two days the capsule was retrieved in the feces. Our patient remained asymptomatic during the entire admission period. Aspiration of a capsule endoscope is a rare complication; to the best of our knowledge this is the first reported case in which a capsule endoscope remained for six days in the bronchial system of a patient without causing airway compromise or pneumonitis and spontaneously returned to the gastrointestinal tract.
A comparative study on liquid core formulation on the diameter on the alginate capsules
NASA Astrophysics Data System (ADS)
Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng
2015-08-01
Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.
Kuipers, Annemarie; Stapels, Daphne A. C.; Weerwind, Lleroy T.; Ko, Ya-Ping; Ruyken, Maartje; Lee, Jean C.; van Kessel, Kok P. M.
2016-01-01
Staphylococcus aureus has developed many mechanisms to escape from human immune responses. To resist phagocytic clearance, S. aureus expresses a polysaccharide capsule, which effectively masks the bacterial surface and surface-associated proteins, such as opsonins, from recognition by phagocytic cells. Additionally, secretion of the extracellular fibrinogen binding protein (Efb) potently blocks phagocytic uptake of the pathogen. Efb creates a fibrinogen shield surrounding the bacteria by simultaneously binding complement C3b and fibrinogen at the bacterial surface. By means of neutrophil phagocytosis assays with fluorescently labelled encapsulated serotype 5 (CP5) and serotype 8 (CP8) strains we compare the immune-modulating function of these shielding mechanisms. The data indicate that, in highly encapsulated S. aureus strains, the polysaccharide capsule is able to prevent phagocytic uptake at plasma concentrations <10 %, but loses its protective ability at higher concentrations of plasma. Interestingly, Efb shows a strong inhibitory effect on both capsule-negative and encapsulated strains at all tested plasma concentrations. Furthermore, the results suggest that both shielding mechanisms can exist simultaneously and collaborate to provide optimal protection against phagocytosis at a broad range of plasma concentrations. As opsonizing antibodies will be shielded from recognition by either mechanism, incorporating both capsular polysaccharides and Efb in future vaccines could be of great importance. PMID:27112346
Kuipers, Annemarie; Stapels, Daphne A C; Weerwind, Lleroy T; Ko, Ya-Ping; Ruyken, Maartje; Lee, Jean C; van Kessel, Kok P M; Rooijakkers, Suzan H M
2016-07-01
Staphylococcus aureus has developed many mechanisms to escape from human immune responses. To resist phagocytic clearance, S. aureus expresses a polysaccharide capsule, which effectively masks the bacterial surface and surface-associated proteins, such as opsonins, from recognition by phagocytic cells. Additionally, secretion of the extracellular fibrinogen binding protein (Efb) potently blocks phagocytic uptake of the pathogen. Efb creates a fibrinogen shield surrounding the bacteria by simultaneously binding complement C3b and fibrinogen at the bacterial surface. By means of neutrophil phagocytosis assays with fluorescently labelled encapsulated serotype 5 (CP5) and serotype 8 (CP8) strains we compare the immune-modulating function of these shielding mechanisms. The data indicate that, in highly encapsulated S. aureus strains, the polysaccharide capsule is able to prevent phagocytic uptake at plasma concentrations <10 %, but loses its protective ability at higher concentrations of plasma. Interestingly, Efb shows a strong inhibitory effect on both capsule-negative and encapsulated strains at all tested plasma concentrations. Furthermore, the results suggest that both shielding mechanisms can exist simultaneously and collaborate to provide optimal protection against phagocytosis at a broad range of plasma concentrations. As opsonizing antibodies will be shielded from recognition by either mechanism, incorporating both capsular polysaccharides and Efb in future vaccines could be of great importance.
Entry Dispersion Analysis for the Stardust Comet Sample Return Capsule
NASA Technical Reports Server (NTRS)
Desai, Prasun N.; Mitcheltree, Robert A.; Cheatwood, F. McNeil
1997-01-01
Stardust will be the first mission to return samples from beyond the Earth-Moon system. The sample return capsule, which is passively controlled during the fastest Earth entry ever, will land by parachute in Utah. The present study analyzes the entry, descent, and landing of the returning sample capsule. The effects of two aerodynamic instabilities are revealed (one in the high altitude free molecular regime and the other in the transonic/subsonic flow regime). These instabilities could lead to unacceptably large excursions in the angle-of-attack near peak heating and main parachute deployment, respectively. To reduce the excursions resulting from the high altitude instability, the entry spin rate of the capsule is increased. To stabilize the excursions from the transonic/subsonic instability, a drogue chute with deployment triggered by an accelerometer and timer is added prior to main parachute deployment. A Monte Carlo dispersion analysis of the modified entry (from which the impact of off-nominal conditions during the entry is ascertained) shows that the capsule attitude excursions near peak heating and drogue chute deployment are within Stardust program limits. Additionally, the size of the resulting 3-sigma landing ellipse is 83.5 km in downrange by 29.2 km in crossrange, which is within the Utah Test and Training Range boundaries.
Effects of alga polysaccharide capsule shells on in-vivo bioavailability and disintegration
NASA Astrophysics Data System (ADS)
Li, Ting; Guo, Shuju; Ma, Lin; Yuan, Yi; Han, Lijun
2012-01-01
Gelatin has been used in hard capsule shells for more than a century, and some shortcomings have appeared, such as high moisture content and risk of transmitting diseases of animal origin to people. Based on available studies regarding gelatin and vegetable shells, we developed a new type of algal polysaccharide capsule (APPC) shells. To test whether our products can replace commercial gelatin shells, we measured in-vivo plasma concentration of 12 selected volunteers with a model drug, ibuprofen, using high performance liquid chromatography (HPLC), by calculating the relative bioavailability of APPC and Qualicaps® referenced to gelatin capsules and assessing bioequivalence of the three types of shells, and calculated pharmacokinetic parameters with the software DAS 2.0 (China). The results show that APPC shells possess bioequivalence with Qualicaps® and gelatin shells. Moreover, the disintegration behavior of four types of shells (APPC, Vegcaps®, Qualicaps® and gelatin shells) with the content of lactose and radioactive element (99mTc) was observed via gamma-scintigraphic images. The bioavailability and gamma-scintigraphic studies showed that APPC was not statistically different from other vegetable and gelatin capsule shells with respect to in-vivo behavior. Hence, it can be concluded that APPCs are exchangeable with other vegetable and gelatin shells.
Kim, Sang Jun; Choi, Yu Seong
2015-01-01
Corticosteroid injection has a wide range of success in adhesive capsulitis but the reason for this has not yet been explained. We hypothesized that this difference might be due to the distribution of the corticosteroids injected into the joint cavity because particulate steroid deposits in the capsule and will not be moved over time by shoulder motion. The purpose of this study is to determine whether the therapeutic efficacy of particulate corticosteroid injection into the glenohumeral joint differs according to the dispersion pattern. Prospective evaluation. Outpatient clinics at a tertiary university hospital. Seventy-two patients diagnosed as having adhesive capsulitis received a corticosteroid injection at the glenohumeral joint. The posterior capsule and the subscapular bursa were selected as dispersion sites and the dispersion of contrast dye was expressed as a ratio (%). Two weeks and 3 months after the injection clinical improvement ("not improved," "slightly improved," "much improved"), numeric rating scale (NRS), and passive range of motions (PROM) were evaluated. The dispersion of the contrast dye was compared according to the clinical improvements by an analysis of variance test. Pearson correlation test was done to find the relationship between PROM and the dispersion and between change of NRS and the dispersion. The distribution in the subscapular area was 30.0% in the "much improved" group, 22.0% in the "slightly improved" group, and 37.1% in the "no improvement" group which was not significantly different (P = 0.179). Correlations between changes of NRS and the dye distribution were not statistically significant (P = 0.429 at 2 weeks and P = 0.629 at 3 months). The change of passive external rotation 3 months after the injection was significantly correlated with the dye distribution (P = 0.035). Because of diverse pathologic findings in adhesive capsulitis, further studies will be needed to address the effect of the dye distribution on the pain improvement according to pathologic findings revealed by magnetic resonance imaging (MRI). External rotation of the shoulder in adhesive capsulitis has greater improvement as the corticosteroid solutions injected into the glenohumeral joint are increasingly dispersed to the subscapularis area. However, this does not affect the pain improvement after the injection.
2012-09-20
CAPE CANAVERAL, Fla. - Test operators examine a model capsule after a of test inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - Test operators prepare a model capsule ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
Lowering the glycemic index of white bread using a white bean extract
Udani, Jay K; Singh, Betsy B; Barrett, Marilyn L; Preuss, Harry G
2009-01-01
Background Phase 2® is a dietary supplement derived from the common white kidney bean (Phaseolus vulgaris). Phase 2 has been shown to inhibit alpha-amylase, the complex carbohydrate digesting enzyme, in vitro. The inhibition of alpha-amylase may result in the lowering of the effective Glycemic Index (GI) of certain foods. The objective of this study was to determine whether the addition of Phase 2 would lower the GI of a commercially available high glycemic food (white bread). Methods An open-label 6-arm crossover study was conducted with 13 randomized subjects. Standardized GI testing was performed on white bread with and without the addition of Phase 2 in capsule and powder form, each in dosages of 1500 mg, 2000 mg, and 3000 mg. Statistical analysis was performed by one-way ANOVA of all seven treatment groups using unadjusted multiple comparisons (t tests) to the white bread control. Results For the capsule formulation, the 1500 mg dose had no effect on the GI and the 2000 mg and 3000 mg capsule doses caused insignificant reductions in GI. For the powder, the 1500 mg and 2000 mg doses caused insignificant reductions in the GI, and the 3000 mg dose had a significant effect (-20.23 or 34.11%, p = 0.023) Conclusion Phase 2 white bean extract appears to be a novel and potentially effective method for reducing the GI of existing foods without modifying their ingredient profile. Trial Registration Trial Registration: ISRCTN50347345 PMID:19860922
Lowering the glycemic index of white bread using a white bean extract.
Udani, Jay K; Singh, Betsy B; Barrett, Marilyn L; Preuss, Harry G
2009-10-28
Phase 2((R)) is a dietary supplement derived from the common white kidney bean (Phaseolus vulgaris). Phase 2 has been shown to inhibit alpha-amylase, the complex carbohydrate digesting enzyme, in vitro. The inhibition of alpha-amylase may result in the lowering of the effective Glycemic Index (GI) of certain foods. The objective of this study was to determine whether the addition of Phase 2 would lower the GI of a commercially available high glycemic food (white bread). An open-label 6-arm crossover study was conducted with 13 randomized subjects. Standardized GI testing was performed on white bread with and without the addition of Phase 2 in capsule and powder form, each in dosages of 1500 mg, 2000 mg, and 3000 mg. Statistical analysis was performed by one-way ANOVA of all seven treatment groups using unadjusted multiple comparisons (t tests) to the white bread control. For the capsule formulation, the 1500 mg dose had no effect on the GI and the 2000 mg and 3000 mg capsule doses caused insignificant reductions in GI. For the powder, the 1500 mg and 2000 mg doses caused insignificant reductions in the GI, and the 3000 mg dose had a significant effect (-20.23 or 34.11%, p = 0.023) Phase 2 white bean extract appears to be a novel and potentially effective method for reducing the GI of existing foods without modifying their ingredient profile. Trial Registration: ISRCTN50347345.
2011-10-15
Stennis Space Center Director Patrick Scheuermann (right) and Naval Meteorology and Oceanography Command Chief of Staff James Pettigrew drop the first shovelfuls of dirt on a time capsule to be opened on the rocket engine test facility's 100th anniversary in 2061. The time capsule was placed in front of the Roy S. Estess Building on Oct. 25 as Stennis concluded celebrations of its 50th anniversary.
A hydrogel capsule as gate dielectric in flexible organic field-effect transistors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dumitru, L. M.; Manoli, K.; Magliulo, M.
2015-01-01
A jellified alginate based capsule serves as biocompatible and biodegradable electrolyte system to gate an organic field-effect transistor fabricated on a flexible substrate. Such a system allows operating thiophene based polymer transistors below 0.5 V through an electrical double layer formed across an ion-permeable polymeric electrolyte. Moreover, biological macro-molecules such as glucose-oxidase and streptavidin can enter into the gating capsules that serve also as delivery system. An enzymatic bio-reaction is shown to take place in the capsule and preliminary results on the measurement of the electronic responses promise for low-cost, low-power, flexible electronic bio-sensing applications using capsule-gated organic field-effect transistors.
Improvement in Capsule Abort Performance Using Supersonic Aerodynamic Interaction by Fences
NASA Astrophysics Data System (ADS)
Koyama, Hiroto; Wang, Yunpeng; Ozawa, Hiroshi; Doi, Katsunori; Nakamura, Yoshiaki
The space transportation system will need advanced abort systems to secure crew against serious accidents. Here this study deals with the capsule-type space transportation systems with a Launch Abort System (LAS). This system is composed of a conic capsule as a Launch Abort Vehicle (LAV) and a cylindrical rocket as a Service Module (SM), and the capsule is moved away from the rocket by supersonic aerodynamic interactions in an emergency. We propose a method to improve the performance of the LAV by installing fences at the edges of surfaces on the rocket and capsule sides. Their effects were investigated by experimental measurements and numerical simulations. Experimental results show that the fences on the rocket and capsule surfaces increase the aerodynamic thrust force on the capsule by 70% in a certain clearance between the capsule and rocket. Computational results show the detailed flow fields where the centripetal flow near the surface on the rocket side is induced by the fence on the rocket side and the centrifugal flow near the surface on the capsule side is blocked by the fence on the capsule side. These results can confirm favorable effects of the fences on the performance of the LAS.
2011-12-02
CAPE CANAVERAL, Fla. – NASA's Liberty Star ship heads into the Atlantic Ocean where tests will be performed on an Orion flight test capsule. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Testing is under way on an Orion flight test capsule in the Atlantic Ocean. The tests are being monitored by workers aboard NASA's Liberty Star ship. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Testing is under way on an Orion flight test capsule in the Atlantic Ocean. The tests are being monitored by workers aboard NASA's Liberty Star ship. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Capsule endoscopy: no longer limited to the small bowel.
Niv, Yaron
2010-03-01
Capsule endoscopy is the latest evolution in gastrointestinal endoscopy and the first to enable complete investigation of the small bowel. Recent new developments in the field of capsule endoscopy include the esophageal capsule (Pilcam ESO) and the colonic capsule (PillCam Colon). esophageal and colonic capsules have two heads with two lenses and cameras. The new capsules have the capability of taking more frames from both sides. The indications for the esophageal capsule examination are diagnosis and follow-up of Barrett's esophagus and esophageal varices. The colonic capsule can be used for colorectal cancer screening and for incomplete colonoscopy. Regarding other new technologies, continuous quality control is needed for the performance, appropriateness of the indications, diagnostic yield, procedure-specific outcome assessment, and cost-effectiveness.
The subtle central effect of nutraceuticals: Is it placebo or nocebo?
Al-Gareeb, Ali I.
2015-01-01
Background: Herbal medicines are often perceived by the general public as a “soft” alternative to Western Medicine, but the use of these substances can be risky since they can induce nocebo effect. Aim: The aim was to evaluate the nocebo effects of Nigella sativa oil, garlic and coenzyme Q10 (CoQ10) on the integrative function of the central nervous system and psychomotor performance. Materials and Methods: This is a randomized, double-blind, controlled, and prospective study conducted in the Department of Pharmacology, College of Medicine, Al-Mustansiriya University, Baghdad, Iraq during February 2013. A total of 160 medical students participated in this study were randomly assigned equally to one of the following groups: Group A: Received single dose of N. sativa oil (500 ml capsule); Group B: Received single dose of garlic (500 mg capsule); Group C: Received single dose of CoQ10 (120 mg capsule) and; Group D: received single dose of matching oral placebo (300 mg starch capsule). For all participants, reaction time and flicker fusion threshold were measured by the Leeds psychomotor performance test battery before and after 3 h of taking the drugs Results: Neither placebo nor nutraceuticals exerted significant effect on total reaction time. Although the recognition reaction time is insignificantly reduced by 2.77% (placebo), 5.83% (Nigella sativa), 7.21% (garlic) and 12.64% (CoQ10) from the pretreatment values, they are adversely affect the motor reaction time to reach the significant level in subjects pretreated with Garlic (P = 0.02). Conclusion: Nutraceuticals are not free from nocebo effect on psychomotor performance. PMID:26401411
The subtle central effect of nutraceuticals: Is it placebo or nocebo?
Al-Gareeb, Ali I
2015-01-01
Herbal medicines are often perceived by the general public as a "soft" alternative to Western Medicine, but the use of these substances can be risky since they can induce nocebo effect. The aim was to evaluate the nocebo effects of Nigella sativa oil, garlic and coenzyme Q10 (CoQ10) on the integrative function of the central nervous system and psychomotor performance. This is a randomized, double-blind, controlled, and prospective study conducted in the Department of Pharmacology, College of Medicine, Al-Mustansiriya University, Baghdad, Iraq during February 2013. A total of 160 medical students participated in this study were randomly assigned equally to one of the following groups: Group A: Received single dose of N. sativa oil (500 ml capsule); Group B: Received single dose of garlic (500 mg capsule); Group C: Received single dose of CoQ10 (120 mg capsule) and; Group D: received single dose of matching oral placebo (300 mg starch capsule). For all participants, reaction time and flicker fusion threshold were measured by the Leeds psychomotor performance test battery before and after 3 h of taking the drugs. Neither placebo nor nutraceuticals exerted significant effect on total reaction time. Although the recognition reaction time is insignificantly reduced by 2.77% (placebo), 5.83% (Nigella sativa), 7.21% (garlic) and 12.64% (CoQ10) from the pretreatment values, they are adversely affect the motor reaction time to reach the significant level in subjects pretreated with Garlic (P = 0.02). Nutraceuticals are not free from nocebo effect on psychomotor performance.
Compatibility tests of materials for a lithium-cooled space power reactor concept
NASA Technical Reports Server (NTRS)
Sinclair, J. H.
1973-01-01
Materials for a lithium-cooled space power reactor concept must be chemically compatible for up to 50,000 hr at high temperature. Capsule tests at 1040 C (1900 F) were made of material combinations of prime interest: T-111 in direct contact with uranium mononitride (UN), Un in vacuum separated from T-111 by tungsten wire, UN with various oxygen impurity levels enclosed in tungsten wire lithium-filled T-111 capsules, and TZM and lithium together in T-111 capsules. All combinations were compatible for over 2800 hr except for T-111 in direct contact with UN.
Experimental investigation of a bioartificial capsule flowing in a narrow tube
NASA Astrophysics Data System (ADS)
Risso, Frédéric; Collé-Paillot, Fabienne; Zagzoule, Mokhtar
This work is an experimental study of the motion and deformation of a bioartificial capsule flowing in a tube of 4 mm diameter. The capsules, initially designed for medical applications, are droplets of salt water surrounded by a thin polymeric membrane. They are immersed in a very viscous Newtonian silicone oil that flows through a tube in the Stokes regime. The properties of the capsules were carefully determined. Two previous experimental papers were devoted to their characterization by osmotic swelling and compression between two plates. The present work also provides a series of tests that allows an accurate definition of the experimental model under investigation. The capsules are buoyant and initially quasi-spherical. Nevertheless, buoyancy and small departures from sphericity are shown to have no significant effects, provided the flowing velocity is large enough for the viscous stress to become predominant. The capsules are also initially slightly over-inflated, but there is no mass transfer through the membrane during the present experiments. Their volume therefore remains constant. The membrane can be described as an elastic two-dimensional material, the elastic moduli of which are independent of the deformation. Far from the tube ends, the capsule reaches a steady state that depends on two parameters: the capillary number, Ca; and the ratio of the radius of the capsule to that of the tube, a/R. The capillary number, which compares the hydrodynamic stresses to the elastic tensions in the membrane, was varied between 0 and 0.125. The radius ratio, which measures the magnitude of the confinement, was varied from 0.75 to 0.95. In the range investigated, the membrane material always remains in the elastic domain. At fixed a/R, the capsule is stretched in the axial direction when Ca is increased. The process of deformation involves two main stages. At small to moderate Ca, the lateral dimension of the capsule decreases whereas its axial length increases. The capsule is rounded at both ends, but the curvature of its rear decreases as Ca increases. At large Ca, the rear buckles inward. Then, the negative rear curvature goes on decreasing whereas the lateral dimension of the capsule reaches a constant value. On the other hand, increasing a/R promotes the deformation: the process remains qualitatively the same, but the different stages are attained for smaller values of Ca. Comparisons with available numerical simulations show that the results are strongly dependent on the properties of the capsules.
NASA Technical Reports Server (NTRS)
Kirk, Lindsay C.; Lillard, Randolph P.; Olejniczak, Joseph; Tanno, Hideyuki
2015-01-01
Computational assessments were performed to size boundary layer trips for a scaled Apollo capsule model in the High Enthalpy Shock Tunnel (HIEST) facility at the JAXA Kakuda Space Center in Japan. For stagnation conditions between 2 MJ/kg and 20 MJ/kg and between 10 MPa and 60 MPa, the appropriate trips were determined to be between 0.2 mm and 1.3 mm high, which provided kappa/delta values on the heatshield from 0.15 to 2.25. The tripped configuration consisted of an insert with a series of diamond shaped trips along the heatshield downstream of the stagnation point. Surface heat flux measurements were obtained on a capsule with a 250 mm diameter, 6.4% scale model, and pressure measurements were taken at axial stations along the nozzle walls. At low enthalpy conditions, the computational predictions agree favorably to the test data along the heatshield centerline. However, agreement becomes less favorable as the enthalpy increases conditions. The measured surface heat flux on the heatshield from the HIEST facility was under-predicted by the computations in these cases. Both smooth and tripped configurations were tested for comparison, and a post-test computational analysis showed that kappa/delta values based on the as-measured stagnation conditions ranged between 0.5 and 1.2. Tripped configurations for both 0.6 mm and 0.8 mm trip heights were able to effectively trip the flow to fully turbulent for a range of freestream conditions.
Su, Jiangli; Liu, Yang; Liu, Yu; Ren, Liqun
2015-01-01
To evaluate the long-term effectiveness of rivastigmine patch or capsule on mild to severe Alzheimer's disease (AD). We performed a meta-analysis of 17 studies regarding the treatment effectiveness of rivastigmine patch or capsule on mild-to-severe AD. Significant difference exists between treatment with rivastigmine patch or capsule and placebo groups (p-value < 0.001). In the Alzheimer's Disease Assessment Scale-Cognitive subscale (ADAS-Cog) score evaluation, a negative weighted mean difference (WMD) was observed in overall and mild-moderate groups after rivastigmine treatment. And in ADAS-ADL score evaluation, a positive WMD was observed in overall groups after rivastigmine treatment. Moreover, WMD value is lower in patch administration subgroup compared to that of capsule administration subgroup. Rivastigmine treatment shows a positive result of improving the condition of patients with mild-to-severe AD. Patch administration shows a stronger effect on decreasing ADAS-Cog score compared to capsule administration.
Verhoef, Petra; Pasman, Wilrike J; Van Vliet, Trinette; Urgert, Rob; Katan, Martijn B
2002-12-01
A high plasma total homocysteine concentration is associated with increased risk of cardiovascular disease. Consumption of unfiltered or filtered coffee raises total homocysteine concentrations in healthy volunteers. The responsible compound, however, is unknown. The objective was to determine whether caffeine explains the homocysteine-raising effect of coffee. Forty-eight subjects aged 19-65 y completed this randomized crossover study with 3 treatments, each lasting 2 wk. Subjects consumed 6 capsules providing 870 mg caffeine/d (test treatment), 0.9 L paper-filtered coffee providing approximately 870 mg caffeine/d, or 6 placebo capsules. Blood samples were drawn fasting and 4 h after consumption of 0.45 L coffee or 3 capsules. The mean fasting plasma homocysteine concentration after the placebo treatment was 9.6 +/- 3.1 micro mol/L. The caffeine and coffee treatments increased fasting homocysteine by 0.4 micro mol/L (95% CI: 0.1, 0.7; P = 0.04), or 5%, and by 0.9 micro mol/L (95% CI: 0.6, 1.2; P = 0.0001), or 11%, respectively, compared with placebo. The increase in homocysteine concentrations 4 h after consumption of 0.45 L coffee relative to consumption of 3 placebo capsules was 19% (P = 0.0001). Caffeine treatment had a much weaker acute effect on homocysteine (4%; P = 0.09). Effects of caffeine were stronger in women than in men, but the effects of coffee did not differ significantly between men and women. Caffeine is partly responsible for the homocysteine-raising effect of coffee. Coffee, but not caffeine, affects homocysteine metabolism within hours after intake, although the effect is still substantial after an overnight fast.
Xiong, Wu; Yan, Yu; Hu, Feng; Liu, Can; Wang, Shaohua; Chen, Jia; Wang, Xueqi; Zhou, Jianda
2016-01-01
Ear reconstruction is one of the most complicated and challenging techniques in plastic surgery because of the histologic and anatomic properties of the ear. Success depends on fitting the auriform cartilage scaffold into the overlying skin, but current approaches can just give results that are not lifelike and can lead to complications. A novel double-capsule, double-valve plastic ear expander was designed and implanted subcutaneously on either side of the dorsum of six New Zealand white rabbits (two expanders per rabbit). The outer capsule was expanded by injecting approximately 120 mL of physiological saline, then withdrawing the liquid on two occasions. Next, the ear-shaped inner capsule was filled with high-hardness plaster, and the external capsule was emptied such that the expanded skin flap and external capsule responded to the negative pressure and closed over the ear-shaped inner capsule. As a result, the skin flap adopted an ear shape. The ear expander was left in place for 4 wk, removed with the help of a mini-incision, and stripped of its fibrous capsule. To simulate human ear reconstruction, the expander was replaced with an auriform silicone prosthesis, and the effects of auricular reconstruction were observed dynamically. All 12 skin flaps maintained abundant blood supply, created a clear outline of the ear framework, and produced a lifelike result. No complications were observed during the 4-wk observation period. The expanded skin flaps described here can mold to the desired contours and appear lifelike, as well as maintain abundant blood supply. This may provide a simpler approach to total ear reconstruction that reduces risk of complications. Copyright © 2016 Elsevier Inc. All rights reserved.
Mihata, Teruhisa; McGarry, Michelle H; Kahn, Timothy; Goldberg, Iliya; Neo, Masashi; Lee, Thay Q
2016-01-01
Acromioplasty is increasingly being performed for both reparable and irreparable rotator cuff tears. However, acromioplasty may destroy the coracoacromial arch, including the coracoacromial ligament, consequently causing a deterioration in superior stability even after superior capsule reconstruction. The purpose of this study was to investigate the effects of acromioplasty on shoulder biomechanics after superior capsule reconstruction for irreparable supraspinatus tendon tears. The hypothesis was that acromioplasty with superior capsule reconstruction would decrease the area of subacromial impingement without increasing superior translation and subacromial contact pressure. Controlled laboratory study. Seven fresh-frozen cadaveric shoulders were evaluated using a custom shoulder testing system. Glenohumeral superior translation, the location of the humeral head relative to the glenoid, and subacromial contact pressure and area were compared among 4 conditions: (1) intact shoulder, (2) irreparable supraspinatus tendon tear, (3) superior capsule reconstruction without acromioplasty, and (4) superior capsule reconstruction with acromioplasty. Superior capsule reconstruction was performed using the fascia lata. Compared with the intact shoulder, the creation of an irreparable supraspinatus tear significantly shifted the humeral head superiorly in the balanced muscle loading condition (without superior force applied) (0° of abduction: 2.8-mm superior shift [P = .0005]; 30° of abduction: 1.9-mm superior shift [P = .003]) and increased both superior translation (0° of abduction: 239% of intact [P = .04]; 30° of abduction: 199% of intact [P = .02]) and subacromial peak contact pressure (0° of abduction: 308% of intact [P = .0002]; 30° of abduction: 252% of intact [P = .001]) by applying superior force. Superior capsule reconstruction without acromioplasty significantly decreased superior translation (0° of abduction: 86% of intact [P = .02]; 30° of abduction: 75% of intact [P = .002]) and subacromial peak contact pressure (0° of abduction: 47% of intact [P = .0002]; 30° of abduction: 83% of intact [P = .0005]; 60° of abduction: 38% of intact [P = .04]) compared with after the creation of a supraspinatus tear. Adding acromioplasty significantly decreased the subacromial contact area compared with superior capsule reconstruction without acromioplasty (0° of abduction: 26% decrease [P = .01]; 30° of abduction: 21% decrease [P = .009]; 60° of abduction: 61% decrease [P = .003]) and did not alter humeral head position, superior translation, or subacromial peak contact pressure. Superior capsule reconstruction repositioned the superiorly migrated humeral head and restored superior stability in the shoulder joint. Adding acromioplasty decreased the subacromial contact area without increasing the subacromial contact pressure. When superior capsule reconstruction is performed for irreparable rotator cuff tears, acromioplasty may help to decrease the postoperative risk of abrasion and tearing of the graft beneath the acromion. © 2015 The Author(s).
Pennings, F H; Kwee, B L S; Vromans, H
2006-01-01
Gelatin exhibits cross-linking upon storage at stress conditions. Capsules stored at these conditions fail to show appropriate in vitro dissolution. The aim of this study is to show the effect of surfactants in the medium on the disintegration of the gelatin capsule. This is demonstrated in the presence and absence of the enzymes pancreatin and pepsin, the function of which is to improve the dissolution. Sodium lauryl sulfate (SLS) and Tween 80 are tested as surfactants. When SLS is used in the medium, dissolution is significantly hampered due to the formation of a less soluble precipitate of gelatin. Compared to SLS, Tween 80 shows far better disintegration and solubility results in dissolution media with neutral or low pH. Therefore, it is concluded in this study that Tween 80 is preferred when a surfactant is necessary to comply with sink condition requirements.
Abang, Sariah; Chan, Eng-Seng; Poncelet, Denis
2012-01-01
The objective of this study was to investigate the effects of process variables on the encapsulation of oil in a calcium alginate membrane using an inverse gelation technique. A dispersion of calcium chloride solution in sunflower oil (water-in-oil emulsion) was added dropwise to the alginate solution. The migration of calcium ions to the alginate solution initiates the formation of a ca-alginate membrane around the emulsion droplets. The membrane thickness of wet capsules and the elastic modulus of dry capsules increased following first-order kinetics with an increasing curing time. An increase in the calcium chloride concentration increased the membrane thickness of wet capsules and the elastic modulus of dry capsules. An increase in the alginate concentration decreased the mean diameter of wet capsules but increased the elastic modulus of dry capsules.
Y. Chen; S. J. Seybold
2013-01-01
Instar determination of field-collected insect larvae has generally been based on the analysis of head capsule width frequency distributions or bivariate plotting, but few studies have tested the validity of such methods. We used head capsules from exuviae of known instars of the beet armyworm, Spodoptera exigua (Hübner) (Lepidoptera: Noctuidae),...
Filali, Samira; Bergamelli, Charlotte; Lamine Tall, Mamadou; Salmon, Damien; Laleye, Diane; Dhelens, Carole; Diouf, Elhadji; Pivot, Christine; Pirot, Fabrice
2017-08-01
A new institutional clinical trial assessed the improvement of sleep disorders in 40 children with autism treated by immediate-release melatonin formulation in different regimens (0.5 mg, 2 mg, and 6 mg daily) for one month. The objectives of present study were to (i) prepare low-dose melatonin hard capsules for pediatric use controlled by two complementary methods and (ii) carry out a stability study in order to determine a use-by-date. Validation of preparation process was claimed as ascertained by mass uniformity of hard capsules. Multicomponent analysis by attenuated total reflectance Fourier transformed infrared (ATR-FTIR) of melatonin/microcrystalline cellulose mixture allowed to identify and quantify relative content of active pharmaceutical ingredients and excipients. Absolute melatonin content analysis by high performance liquid chromatography in 0.5 mg and 6 mg melatonin capsules was 93.6%±4.1% and 98.7%±6.9% of theoretical value, respectively. Forced degradation study showed a good separation of melatonin and its degradation products. The capability of the method was 15, confirming a risk of false negative <0.01%. Stability test and dissolution test were compliant over 18 months of storage with European Pharmacopoeia. Preparation of melatonin hard capsules was completed manually and melatonin in hard capsules was stable for 18 months, in spite of low doses of active ingredient. ATR-FTIR offers a real alternative to HPLC for quality control of high-dose melatonin hard capsules before the release of clinical batches.
Sharma, Rashmi S; Joy, Raechel C; Boushey, Carol J; Ferruzzi, Mario G; Leonov, Alexei P; McCrory, Megan A
2014-03-01
Para-aminobenzoic acid (PABA) has long been used as an objective measure to assess completeness of 24-hour urine collections. However, pharmaceutical-grade PABA for human ingestion is not available in the United States. An alternative, the potassium salt of PABA, aminobenzoate potassium, can be obtained for clinical use, although it has not yet been validated in this role. Both PABA and aminobenzoate potassium can be directly ingested in their tablet or capsule forms or added to food before consumption. Our aim was to investigate the effect of form (PABA vs aminobenzoate potassium) and administration mode (directly ingested as a tablet/capsule vs added to food) on urinary PABA recovery levels. Twenty healthy participants underwent 3 test days separated by two 24-hour wash-out periods. Three test conditions, one on each test day, were investigated in randomized order: PABA tablet, aminobenzoate potassium capsule, and PABA or aminobenzoate potassium in food. Ingestion of each dose was supervised and participants performed the 24-hour urine collections while free-living. The 24-hour urine collections were analyzed for PABA recovery (%R) levels using a colorimetric assay. Recoveries 85% to 110% were deemed complete and those >110% were reanalyzed by high pressure liquid chromatography and mass spectrometry. Only complete collections (>85%R) were included in analyses. The recovery for the PABA tablet, aminobenzoate potassium capsule, and PABA/aminobenzoate potassium in food were similar at 98.8%R±2.0%R, 95.1%R±2.3%R, and 93.2%R±2.1%R, respectively, and did not differ significantly. These results suggest that aminobenzoate potassium may be used as an alternative to PABA for assessing the completeness of 24-hour urine collections and to track compliance with consuming provided diets in community-dwelling studies. Copyright © 2014 Academy of Nutrition and Dietetics. Published by Elsevier Inc. All rights reserved.
Fischer, R; Schütz, H; Grossmann, M; Leis, H J; Ammer, R
2006-03-01
To assess bioequivalence between an intact capsule and the content of a capsule sprinkled on applesauce. Medikinet retard 20 mg capsules were obtained from Medice (Iserlohn, Germany). This was a single-center, completely randomized, open, 2-period, 2-sequence, balanced crossover study with a washout period of 1 week between administrations, in 12 healthy male and female subjects, aged 18-45 years. Blood samples were collected over 24 hours and methylphenidate plasma concentration-time data were used to calculate pharmacokinetic parameters for both administrations. The main parameters were (confirmatory) AUC0-tz (extent of BA), Cmax, tmax (rate of BA) and (descriptively) AUC0-infinity and t1/2. Equivalence was concluded if the 90% confidence interval (CI) for the ratio between test and reference was 0.80-1.25 (AUC0-tz). All 12 dosed subjects finished both treatment periods and were included in pharmacokinetic and safety analyses. 90% geometric confidence intervals for AUC0-tz and Cmax data were well within accepted bioequivalence limits. The study has shown that both treatment modes lead to similar pattern of absorption and elimination following single-dose administration in the fed state. The test treatment (content of capsule sprinkled over 15 ml applesauce) is bioequivalent to the reference treatment (intact capsule) in terms of extent and rate of absorption. Data collected from this study demonstrate that Medikinet retard capsules can be opened and the content sprinkled on a tablespoon of applesauce without influencing the rate and extent of bioavailability.
Cluster Development Test 2: An Assessment of a Failed Test
NASA Technical Reports Server (NTRS)
Machin, Ricardo A.; Evans, Carol T.
2009-01-01
On 31 July 2008 the National Aeronautics and Space Administration Crew Exploration Vehicle Parachute Assembly System team conducted the final planned cluster test of the first generation parachute recovery system design. The two primary test objectives were to demonstrate the operation of the complete parachute system deployed from a full scale capsule simulator and to demonstrate the test technique of separating the capsule simulator from the Low Velocity Air Drop pallet used to extract the test article from a United States Air Force C-17 aircraft. The capsule simulator was the Parachute Test Vehicle with an accurate heat shield outer mold line and forward bay compartment of the Crew Exploration Vehicle Command Module. The Parachute Test Vehicle separated cleanly from the pallet following extraction, but failed to reach test conditions resulting in the failure of the test and the loss of the test assets. No personnel were injured. This paper will discuss the design of the test and the findings of the team that investigated the test, including a discussion of what were determined to be the root causes of the failure.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Core, Gregory Matthew
This report contains a summary of irradiation testing of Fuel Cycle Research and Development (FCRD) Accident Tolerant Fuels Series 1 (ATF 1) experiments performed at Idaho National Laboratory (INL) in FY 2016. ATF 1 irradiation testing work performed in FY 2016 included design, analysis, and fabrication of ATF-1B drop in capsule ATF 1 series experiments and irradiation testing of ATF-1 capsules in the ATR.
Tulloch, Simon J; Zhang, Yuxin; McLean, Angus; Wolf, Kathleen N
2002-11-01
To assess the bioavailability of three test formulations of a single dose of extended-release Adderall 20-mg capsules compared with two doses of immediate-release Adderall 10-mg tablets, and to assess the bioequivalence of a single 30-mg dose of the chosen extended-release Adderall formulation (designated as SLI381) administered in applesauce (sprinkled) and the same dose administered as an intact capsule with or without food. Randomized, open-label, crossover study. Clinical research unit. Forty-one healthy adults. Study A had four treatment sequences: three test formulations (A, B, and C) of a single dose of extended-release Adderall 20 mg, and two 10-mg doses of Adderall given 4 hours apart. Study B had three treatment sequences: a single dose of SLI381 30 mg as an intact capsule after overnight fast, an intact capsule after a high-fat breakfast, and the contents of a capsule sprinkled in 1 tablespoon of applesauce. The 20-mg test formulation A had comparable pharmacokinetic profiles and bioequivalence in rate and extent of drug absorption to Adderall 10 mg twice/day for both d- and l-amphetamine. Formulations B and C had statistically significant differences from the reference drug in some pharmacokinetic parameters. A 30-mg dose of SLI381 showed no significant differences in rate and extent of absorption of d- and l-amphetamine for fasted or sprinkled conditions compared with the high-fat meal condition. SLI381 20 mg/day is bioequivalent to Adderall 10 mg twice/day. SLI381 30 mg administered in applesauce is bioequivalent in terms of both rate and extent of absorption to the same dose administered as an intact capsule in both fasted and fed states.
AGC-2 Specimen Post Irradiation Data Package Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Windes, William Enoch; Swank, W. David; Rohrbaugh, David T.
This report documents results of the post-irradiation examination material property testing of the creep, control, and piggyback specimens from the irradiation creep capsule Advanced Graphite Creep (AGC)-2 are reported. This is the second of a series of six irradiation test trains planned as part of the AGC experiment to fully characterize the neutron irradiation effects and radiation creep behavior of current nuclear graphite grades. The AGC-2 capsule was irradiated in the Idaho National Laboratory Advanced Test Reactor at a nominal temperature of 600°C and to a peak dose of 5 dpa (displacements per atom). One-half of the creep specimens weremore » subjected to mechanical stresses (an applied stress of either 13.8, 17.2, or 20.7 MPa) to induce irradiation creep. All post-irradiation testing and measurement results are reported with the exception of the irradiation mechanical strength testing, which is the last destructive testing stage of the irradiation testing program. Material property tests were conducted on specimens from 15 nuclear graphite grades using a similar loading configuration as the first AGC capsule (AGC-1) to provide easy comparison between the two capsules. However, AGC-2 contained an increased number of specimens (i.e., 487 total specimens irradiated) and replaced specimens of the minor grade 2020 with the newer grade 2114. The data reported include specimen dimensions for both stressed and unstressed specimens to establish the irradiation creep rates, mass and volume data necessary to derive density, elastic constants (Young’s modulus, shear modulus, and Poisson’s ratio) from ultrasonic time-of-flight velocity measurements, Young’s modulus from the fundamental frequency of vibration, electrical resistivity, and thermal diffusivity and thermal expansion data from 100–500°C. No data outliers were determined after all measurements were completed. A brief statistical analysis was performed on the irradiated data and a limited comparison between pre- and post-irradiation properties is presented. A more complete evaluation of trends in the material property changes, as well as irradiation-induced creep due to irradiation, temperature, and applied load on specimens will be discussed in later AGC-2 post-irradiation examination analysis reports.« less
In-reactor performance of LWR-type tritium target rods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lanning, D.D.; Paxton, M.M.; Crumbaugh, L.
Pacific Northwest Laboratory has conducted several 1-yr irradiation tests of light water reactor-type tritium target rods. These tests have been sponsored by the U.S. Department of Energy's Office of New Production Reactors. The first test, designated water capsule-1 (WC-1), was conducted in the Advanced Test Reactor (ATR) at the Idaho National Engineering Laboratory from November 1989 to December 1990. The test vehicle contained a single 4-ft target rod within a pressurized water capsule. The capsule maintained the rod at pressurized water reactor (PWR)-type water temperature and pressure conditions. Posttest nondestructive examinations of the WC-1 rod involved visual examinations, dimensional checks,more » gamma scanning, and neutron radiography. The results indicate that the rod maintained the integrity of its pressure seal and was otherwise unaltered both mechanically and dimensionally by its irradiation and posttest handling.« less
2011-12-02
CAPE CANAVERAL, Fla. – Workers, on the deck of NASA's Liberty Star ship and in a boat in the Atlantic Ocean, prepare to begin testing of an Orion flight test capsule. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Workers on the deck of NASA's Liberty Star ship prepare for testing in the Atlantic Ocean of an Orion flight test capsule to begin. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – Workers on the deck of NASA's Liberty Star ship prepare for testing in the Atlantic Ocean of an Orion flight test capsule to begin. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, D. A.; Smalyuk, V. A.; MacPhee, A. G.
Hydrodynamic instability growth of the capsule support membranes (or “tents”) and fill tubes has been studied in spherical, glow discharge polymer plastic capsule implosions at the National Ignition Facility (NIF). In NIF implosions, the capsules are supported by tents because the nominal 10-μm thick fill tubes are not strong enough to support capsules by themselves. After it was recognized that the tents had a significant impact of implosion stability, new support methods were investigated, including thicker, 30-μm diameter fill tubes and cantilevered fill tubes, as described in this article. A new “sub-scale” version of the existing x-ray radiography platform wasmore » developed for measuring growing capsule perturbations in the acceleration phase of implosions. It was calibrated using hydrodynamic growth measurements of pre-imposed capsule modulations with Legendre modes of 60, 90, 110, and 140 at convergence ratios up to ~2.4. Subsequent experiments with 3-D perturbations have studied instability growth of 10-μm and 30-μm thick fill tubes to compare them with 30-nm thick tent perturbations at convergence ratios up to ~3. In other experiments, the perturbations from cantilevered fill tubes were measured and compared to the tent perturbations. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by 100 μm, 200 μm, and 300 μm from the capsule surfaces. Based on these experiments, 30-μm thick fill tubes and 300-μm offset cantilevered fill tubes were recommended for further tests using layered deuterium-tritium implosions. In conclusion, the effects of x-ray shadowing during the drive and oxygen-induced perturbations during target assembly produced additional seeds for instabilities and were also measured in these experiments.« less
Martinez, D. A.; Smalyuk, V. A.; MacPhee, A. G.; ...
2017-10-20
Hydrodynamic instability growth of the capsule support membranes (or “tents”) and fill tubes has been studied in spherical, glow discharge polymer plastic capsule implosions at the National Ignition Facility (NIF). In NIF implosions, the capsules are supported by tents because the nominal 10-μm thick fill tubes are not strong enough to support capsules by themselves. After it was recognized that the tents had a significant impact of implosion stability, new support methods were investigated, including thicker, 30-μm diameter fill tubes and cantilevered fill tubes, as described in this article. A new “sub-scale” version of the existing x-ray radiography platform wasmore » developed for measuring growing capsule perturbations in the acceleration phase of implosions. It was calibrated using hydrodynamic growth measurements of pre-imposed capsule modulations with Legendre modes of 60, 90, 110, and 140 at convergence ratios up to ~2.4. Subsequent experiments with 3-D perturbations have studied instability growth of 10-μm and 30-μm thick fill tubes to compare them with 30-nm thick tent perturbations at convergence ratios up to ~3. In other experiments, the perturbations from cantilevered fill tubes were measured and compared to the tent perturbations. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by 100 μm, 200 μm, and 300 μm from the capsule surfaces. Based on these experiments, 30-μm thick fill tubes and 300-μm offset cantilevered fill tubes were recommended for further tests using layered deuterium-tritium implosions. In conclusion, the effects of x-ray shadowing during the drive and oxygen-induced perturbations during target assembly produced additional seeds for instabilities and were also measured in these experiments.« less
NASA Astrophysics Data System (ADS)
Martinez, D. A.; Smalyuk, V. A.; MacPhee, A. G.; Milovich, J.; Casey, D. T.; Weber, C. R.; Robey, H. F.; Chen, K.-C.; Clark, D. S.; Crippen, J.; Farrell, M.; Felker, S.; Field, J. E.; Haan, S. W.; Hammel, B. A.; Hamza, A. V.; Stadermann, M.; Hsing, W. W.; Kroll, J. J.; Landen, O. L.; Nikroo, A.; Pickworth, L.; Rice, N.
2017-10-01
Hydrodynamic instability growth of the capsule support membranes (or "tents") and fill tubes has been studied in spherical, glow discharge polymer plastic capsule implosions at the National Ignition Facility (NIF) [Campbell et al., AIP Conf. Proc. 429, 3 (1998)]. In NIF implosions, the capsules are supported by tents because the nominal 10-μm thick fill tubes are not strong enough to support capsules by themselves. After it was recognized that the tents had a significant impact of implosion stability, new support methods were investigated, including thicker, 30-μm diameter fill tubes and cantilevered fill tubes, as described in this article. A new "sub-scale" version of the existing x-ray radiography platform was developed for measuring growing capsule perturbations in the acceleration phase of implosions. It was calibrated using hydrodynamic growth measurements of pre-imposed capsule modulations with Legendre modes of 60, 90, 110, and 140 at convergence ratios up to ˜2.4. Subsequent experiments with 3-D perturbations have studied instability growth of 10-μm and 30-μm thick fill tubes to compare them with 30-nm thick tent perturbations at convergence ratios up to ˜3. In other experiments, the perturbations from cantilevered fill tubes were measured and compared to the tent perturbations. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by 100 μm, 200 μm, and 300 μm from the capsule surfaces. Based on these experiments, 30-μm thick fill tubes and 300-μm offset cantilevered fill tubes were recommended for further tests using layered deuterium-tritium implosions. The effects of x-ray shadowing during the drive and oxygen-induced perturbations during target assembly produced additional seeds for instabilities and were also measured in these experiments.
Mechanistic study of the azithromycin dosage-form-dependent food effect.
Curatolo, William; Foulds, George; Labadie, Robert
2010-07-01
Azithromycin capsules are known to exhibit a negative food effect, manifest as a decrease in azithromycin bioavailability in the fed state. Azithromycin tablets are known to be bioequivalent to capsules in the fasted state, but do not exhibit a food effect. In the present study, the involvement of gastric degradation of azithromycin to des-cladinose azithromycin (DCA) has been investigated as a possible mechanism for the observed capsule food effect. Healthy volunteers were dosed with azithromycin tablets and capsules, fasted and fed, in a four-way randomized crossover study. Serum levels of DCA were measured as a function of time post-dose. Natural log-transformed PK parameters were statistically analyzed using an ANOVA model appropriate for the study design. When capsules were dosed to fed subjects, the systemic AUC for DCA was 243% of the value observed after fasted-state dosing, and the DCA C(max) was 270% of the value observed after fasted-state dosing. When azithromycin tablets were dosed in the fasted and fed states, there was no significant difference in systemic DCA. Gastric degradation of azithromycin to DCA is the likely mechanism for the observed negative food effect observed for azithromycin capsules. This effect is not observed for tablets. These observations suggest that azithromycin capsules exhibit slow and/or delayed disintegration in the fed stomach, resulting in extended gastric residence and degradation of a portion of the gastrically retained azithromycin.
Haines, Brian M.; Yi, S. A.; Olson, R. E.; ...
2017-07-10
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. In this paper, we present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surfacemore » roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Finally and nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).« less
NASA Astrophysics Data System (ADS)
Haines, Brian M.; Yi, S. A.; Olson, R. E.; Khan, S. F.; Kyrala, G. A.; Zylstra, A. B.; Bradley, P. A.; Peterson, R. R.; Kline, J. L.; Leeper, R. J.; Shah, R. C.
2017-07-01
The wetted foam capsule design for inertial confinement fusion capsules, which includes a foam layer wetted with deuterium-tritium liquid, enables layered capsule implosions with a wide range of hot-spot convergence ratios (CR) on the National Ignition Facility. We present a full-scale wetted foam capsule design that demonstrates high gain in one-dimensional simulations. In these simulations, increasing the convergence ratio leads to an improved capsule yield due to higher hot-spot temperatures and increased fuel areal density. High-resolution two-dimensional simulations of this design are presented with detailed and well resolved models for the capsule fill tube, support tent, surface roughness, and predicted asymmetries in the x-ray drive. Our modeling of these asymmetries is validated by comparisons with available experimental data. In 2D simulations of the full-scale wetted foam capsule design, jetting caused by the fill tube is prevented by the expansion of the tungsten-doped shell layer due to preheat. While the impacts of surface roughness and predicted asymmetries in the x-ray drive are enhanced by convergence effects, likely underpredicted in 2D at high CR, simulations predict that the capsule is robust to these features. Nevertheless, the design is highly susceptible to the effects of the capsule support tent, which negates all of the one-dimensional benefits of increasing the convergence ratio. Indeed, when the support tent is included in simulations, the yield decreases as the convergence ratio is increased for CR > 20. Nevertheless, the results suggest that the full-scale wetted foam design has the potential to outperform ice layer capsules given currently achievable levels of asymmetries when fielded at low convergence ratios (CR < 20).
Design and synthesis of organic-inorganic hybrid capsules for biotechnological applications.
Shi, Jiafu; Jiang, Yanjun; Wang, Xiaoli; Wu, Hong; Yang, Dong; Pan, Fusheng; Su, Yanlei; Jiang, Zhongyi
2014-08-07
Organic-inorganic hybrid capsules, which typically possess a hollow lumen and a hybrid wall, have emerged as a novel and promising class of hybrid materials and have attracted enormous attention. In comparison to polymeric capsules or inorganic capsules, the hybrid capsules combine the intrinsic physical/chemical properties of the organic and inorganic moieties, acquire more degrees of freedom to manipulate multiple interactions, create hierarchical structures and integrate multiple functionalities. Thus, the hybrid capsules exhibit superior mechanical strength (vs. polymeric capsules) and diverse functionalities (vs. inorganic capsules), which may give new opportunities to produce high-performance materials. Much effort has been devoted to exploring innovative and effective methods for the synthesis of hybrid capsules that exhibit desirable performance in target applications. This tutorial review firstly presents a brief description of the capsular structure and hybrid materials in nature, then classifies the hybrid capsules into molecule-hybrid capsules and nano-hybrid capsules based upon the size of the organic and inorganic moieties in the capsule wall, followed by a detailed discussion of the design and synthesis of the hybrid capsules. For each kind of hybrid capsule, the state-of-the-art synthesis methods are described in detail and a critical comment is embedded. The applications of these hybrid capsules in biotechnological areas (biocatalysis, drug delivery, etc.) have also been summarized. Hopefully, this review will offer a perspective and guidelines for the future research and development of hybrid capsules.
Simulation and evaluation of rupturable coated capsules by finite element method.
Yang, Yan; Fang, Jie; Shen, Lian; Shan, Weiguang
2017-03-15
The objective of this study was to simulate and evaluate the burst behavior of rupturable coated capsules by finite element method (FEM). Film and coated capsules were prepared by dip-coating method and their dimensions were determined by stereomicroscope. Mechanical properties of the film were measured by tensile test and used as material properties of FEM models. Swelling pressure was determined by restrained expansion method and applied to the internal surface of FEM models. Water uptake of coated capsules was determined to study the formation of internal pressure. Burst test and in vitro dissolution was used to verify the FEM models, which were used to study and predict the coating burst behavior. Simulated results of coating burst behavior were well agreed with the experiment results. Swelling pressure, material properties and dimensions of coating had influence on the maximum stress. Burst pressure and critical L-HPC content were calculated for burst prediction and formulation optimization. FEM simulation was a feasible way to simulate and evaluate the burst behavior of coated capsules. Copyright © 2017 Elsevier B.V. All rights reserved.
Wanders, Anne J; Feskens, Edith J M; Jonathan, Melliana C; Schols, Henk A; de Graaf, Cees; Mars, Monica
2014-04-10
An increased intake of dietary fiber has been associated with reduced appetite and reduced energy intake. Research on the effects of seemingly identical classes of dietary fiber on appetite has, however, resulted in conflicting findings. The present study investigated the effects of different fiber properties, including methods of supplementation, on appetite and energy intake. This was a randomized crossover study with 29 subjects (21±2 y, BMI: 21.9±1.8 kg/m(2)) consuming dairy based liquid test products (1.5 MJ, 435 g) containing either: no pectin, bulking pectin (10 g), viscous pectin (10 g), or gelled pectin (10 g). The gelled pectin was also supplemented as capsules (10 g), and as liquid (10 g). Physicochemical properties of the test products were assessed. Appetite, glucose, insulin and gastric emptying were measured before ingestion and after fixed time intervals. Energy intake was measured after 3 h. Preload viscosity was larger for gelled>viscous>bulking>no pectin, and was larger for gelled>liquid>capsules. Appetite was reduced after ingestion of gelled pectin compared to bulking (p<0.0001), viscous (p=0.005) and no pectin (p<0.0001), without differences in subsequent energy intake (p=0.32). Gastric emptying rate was delayed after gelled pectin (82±18 min) compared to no pectin (70±19 min, p=0.015). Furthermore, gelled (p=0.002) and viscous (p<0.0001) pectin lowered insulin responses compared to no pectin, with minor reductions in glucose response. Regarding methods of supplementation, appetite was reduced after ingestion of the gelled test product compared to after capsules (p<0.0001) and liquid (p<0.0001). Energy intake was lower after ingestion of capsules compared to liquid (-12.4%, p=0.03). Different methods of supplementation resulted in distinct metabolic parameters. Results suggest that different physicochemical properties of pectin, including methods of supplementation, impact appetite and energy intake differently. Reduced appetite was probably mediated by preload physical properties, whereas inconsistent associations with metabolic parameters were found. Copyright © 2014 Elsevier Inc. All rights reserved.
Carbide fuel pin and capsule design for irradiations at thermionic temperatures
NASA Technical Reports Server (NTRS)
Siegel, B. L.; Slaby, J. G.; Mattson, W. F.; Dilanni, D. C.
1973-01-01
The design of a capsule assembly to evaluate tungsten-emitter - carbide-fuel combinations for thermionic fuel elements is presented. An inpile fuel pin evaluation program concerned with clad temperture, neutron spectrum, carbide fuel composition, fuel geometry,fuel density, and clad thickness is discussed. The capsule design was a compromise involving considerations between heat transfer, instrumentation, materials compatibility, and test location. Heat-transfer calculations were instrumental in determining the method of support of the fuel pin to minimize axial temperature variations. The capsule design was easily fabricable and utilized existing state-of-the-art experience from previous programs.
1959-09-01
An Atlas launch vehicle carrying the Big Joe capsule leaves its launching pad on a 2,000-mile ballistic flight to the altitude of 100 miles. The Big Joe capsule is a boilerplate model of the marned orbital capsule under NASA's Project Mercury. The capsule was recovered and studied for the effect of re-entry heat and other flight stresses.
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule seen ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule seen ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule seen ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule falls during tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule falls during tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule following a test inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule seen ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - A model capsule falls during tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
Underway Recovery Test 6 (URT-6) - Day 4 Afternoon Activities
2018-01-20
Sailors from the USS Anchorage simulate “Oscar,” a dummy used for man overboard drills, to the medical unit. During Underway Recovery Test 6, the USS Anchorage’s man overboard drill gave Kennedy Space Center’s NASA Recovery Team a glimpse of one way an astronaut could be brought from a small boat onto the ship using a stretcher. Once the Orion capsule splashes down in the Pacific Ocean, astronauts can choose to stay in the capsule until it is pulled into the well deck of the Navy vessel, or have a diver retrieve them in the open water and then get the capsule later.
Underway Recovery Test 6 (URT-6) - Day 4 Afternoon Activities
2018-01-20
USS Anchorage’s Deck Department is heaving around the line as they bring up “Oscar,” a dummy used for man overboard drills. During Underway Recovery Test 6, the USS Anchorage’s man overboard drill gave Kennedy Space Center’s NASA Recovery Team a glimpse of one way an astronaut could be brought from a small boat onto the ship using a stretcher. Once the Orion capsule splashes down in the Pacific Ocean, astronauts can choose to stay in the capsule until it is pulled into the well deck of the Navy vessel, or have a diver retrieve them first and then get the capsule later.
Myo-inositol soft gel capsules may prevent the risk of coffee-induced neural tube defects.
De Grazia, Sara; Carlomagno, Gianfranco; Unfer, Vittorio; Cavalli, Pietro
2012-09-01
Neural tube defects (NTDs) are classified as folate sensitive (about 70%) and folate resistant (about 30%); although folic acid is able to prevent the former, several data have shown that inositol may prevent the latter. It has recently been proposed that coffee intake might represent a risk factor for NTD, likely by interfering with the inositol signaling. In the present study, we tested the hypothesis that, beside affecting the inositol signaling pathway, coffee also interferes with inositol absorption. In order to evaluate coffee possible negative effects on inositol gastrointestinal absorption, a single-dose bioavailability trial was conducted. Pharmacokinetics (PK) parameters of myo-inositol (MI) powder and MI soft gelatin capsules swallowed with water and with a single 'espresso' were compared. PK profiles were obtained by analysis of MI plasma concentration, and the respective MI bioavailability was compared. Myo-inositol powder administration was negatively affected by coffee intake, thus suggesting an additional explanation to the interference between inositol deficiency and coffee consumption. On the contrary, the concomitant single 'espresso' consumption did not affect MI absorption following MI soft gelatin capsules administration. Furthermore, it was observed that MI soft gelatin capsule administration resulted in improved bioavailability compared to the MI powder form. Myo-inositol soft gelatin capsules should be considered for the preventive treatment of NTDs in folate-resistant subjects due to their higher bioavailability and to the capability to reduce espresso interference.
Mercury Capsule Model in the 1- by 1-Foot Supersonic Wind Tunnel
1959-10-21
National Aeronautics and Space Administration (NASA) researchers install a small-scale model of the capsule for Project Mercury in the 1- by 1-Foot Supersonic Wind Tunnel at the Lewis Research Center. NASA Lewis conducted a variety of tests for Project Mercury, including retrorocket calibration, escape tower engine performance, and separation of the capsule from simulated Atlas and Redstone boosters. The test of this capsule and escape tower model in the 1- by 1-foot tunnel were run in January and February 1960. The 1-by 1-Foot Supersonic Wind Tunnel had a 15-inch long test section, seen here, that was one foot wide and one foot high. The sides were made of glass to allow cameras to capture the supersonic air flow over the models. The tunnel could generate air flows from Mach 1.3 to 3.0. At the time, it was one of nine small supersonic wind tunnels at Lewis. These tunnels used the exhauster and compressor equipment of the larger facilities. The 1- by 1 tunnel, which began operating in the early 1950s, was built inside a test cell in the expansive Engine Research Building. During the 1950s the 1- by 1 was used to study a variety of inlets, nozzles, and cones for missiles and scramjets. The Mercury capsule tests were among the last at the facility for many years. The tunnel was mothballed in 1960. The 1- by 1 was briefly restored in 1972, then brought back online for good in 1979. The facility has maintained a brisk operating schedule ever since.
SHARK: Flight Results of an UHTC-Based Nose Related to USV Hot Structures
NASA Astrophysics Data System (ADS)
Gardi, R.; Del Vecchio, A.; Russo, G.; Marino, G.
2011-05-01
In the frame of USV program, CIRA is developing different projects aimed to develop new technologies for the future hypersonic vehicles. One of these technological projects is Sharp Hot Structures (SHS) and it is aimed to the realization of innovative thermo- structures, based on innovative material solution, able to sustain the heat loads generated during the hypersonic flight. Because the slender configuration of the USV program vehicles, SHS is focused on sharp geometries, like sharp leading edges and sharp nose cones. CIRA, for many years, is investigating the effectiveness of ultra high temperature ceramic materials (UHTC) by means of numerical simulations, ground testing in plasma torch and in SCIROCCO, the 70MW plasma wind tunnel (PWT) facility at CIRA. More recently CIRA is moving the experimentation in real flight environment, boarding UHTC components on the re-entering space capsules EXPERT and SHARK. The former is a European experimental test bed boarding a couple of UHTC fins, already qualified and integrated on the vehicle. SHARK is a 20kg capsule launched on March the 26th 2010 from Kiruna with the European sounding rocker Maxus-8. During the ascent parabola, the capsule was released and successfully executed its 15 minutes ballistic flight and then re-entered in the atmosphere from a 700km altitude. The capsule has been recovered on July the 1st and all data have been acquired. All the instrumentation worked nicely and the data acquisition continued even after the landing, confirming the robustness of the design.
NASA Astrophysics Data System (ADS)
Gora, Michalina J.; Simmons, Leigh H.; Tiernan, Aubrey R.; Grant, Catriona N.; Soomro, Amna R.; Walker Corkery, Elizabeth S.; Rosenberg, Mireille; Metlay, Joshua P.; Tearney, Guillermo J.
2016-03-01
We have developed a swallowable tethered capsule OCT endomicroscopy (TCE) device that acquires microscopic images of the entire esophagus in unsedated subjects in a quick and comfortable procedure. To test its capabilities of TCE to become a population-based screening device, we conducted a clinical feasibility study in the primary care office. The swept-source OCT imaging system (1310nm central wavelength, 40kHz A-line rate, 10um axial resolution) together with the tethered capsule catheter (11x25mm capsule attached to a flexible tether) were transferred to the PCP office where unsedated patients scheduled for non-urgent PCP visits swallowed the capsule and microscopic OCT images of the entire esophagus were collected. After the whole length of the esophagus was imaged, the catheter was disinfected for reuse. Twenty subjects were enrolled in the study, including nine female and eleven male. All TCE procedures were performed by a nurse and lasted in average 5:42 ± 1:54 min. High-resolution images of the esophagus were obtained in all seventeen subjects that swallowed the capsule. Our clinical experience in this cohort, subject feedback, image quality, and technological adaptations for efficient utilization in this setting will be presented. The ease and simplicity of the procedure combined with high quality of the images demonstrate the potential for this technology to become a population-based screening device. Technology limitations and future development guided by findings from this initial experience will be discussed with the goal of effectively translating TCE to the outpatient primary care setting.
Gheorghe, Andrada; Zahiu, Denise Carmen Mihaela; Voiosu, Theodor Alexandru; Mateescu, Bogdan Radu; Voiosu, Mihail Radu; Rimbaş, Mihai
2017-06-01
As already known, spondyloarthritis patients present a striking resemblance in intestinal inflammation with early Crohn's disease. Moreover, the frequent use of nonsteroidal anti-inflammatory drugs is an important part of their treatment. Both conditions could lead to intestinal stenoses. Therefore we proposed to investigate the usefulness of the patency capsule test in patients with spondyloarthritis. 64 consecutive patients (33 males; mean age 38 ± 11 years) that fulfilled the AMOR criteria for seronegative spondyloarthropathy (59.4% ankylosing spondylitis) lacking symptoms or signs of intestinal stenosis were enrolled and submitted to an AGILE™ capsule patency test followed by a video capsule endoscopy (PillCam SB2™), as part of a protocol investigating the presence of intestinal inflammatory lesions. After reviewing the VCE recordings, the Lewis score (of small bowel inflammatory involvement) was computed. In only 5 patients (7.8%) of the study group, the luminal patency test was negative. However, there was no retention of the videocapsule in any of the patients. From the 59 patients with a positive patency test, 3 patients presented single small bowel stenoses (two with ulcerated overlying inflamed mucosa, one cicatricial), all being traversed by the videocapsule along the length of the recording. None of the patients with a negative test had bowel stenoses. There was no correlation between the patency test and the Lewis score, the C reactive protein value, diagnosis of inflammatory bowel disease, or the family history of spondyloarthritis, psoriasis or inflammatory bowel disease. The AGILE patency capsule does not seem to be a useful tool for all patients with spondyloarthritis prior to small bowel videocapsule endoscopy (ClinicalTrial.gov ID NCT 00768950).
Oh, D Alexander; Parikh, Neha; Khurana, Varun; Cognata Smith, Christina; Vetticaden, Santosh
2017-01-01
Dronabinol is a pharmaceutical tetrahydrocannabinol originally developed as an oral capsule. A dronabinol oral solution was recently approved, and the effects of food on absorption and bioavailability of the oral solution versus capsules were compared in an open-label, single-dose, 3-period crossover study. Healthy volunteers were randomized to either dronabinol oral solution 4.25 mg (fed) or dronabinol capsule 5 mg (fed or fasted). Dosing was separated by a 7-day washout period. Plasma pharmacokinetics were evaluated for dronabinol and its major metabolite, 11-hydroxy-delta-9-tetrahydrocannabinol (11-OH-Δ9-THC). Pharmacokinetic data were available for analysis in 54 volunteers. In the fed state, initial dronabinol absorption was faster with oral solution versus capsule (mean time to the first measurable concentration, 0.15 vs 2.02 hours, respectively), with 100% and 15% of volunteers, respectively, having detectable plasma dronabinol levels 30 minutes postdose. There was less interindividual variability in plasma dronabinol concentration during early absorption with oral solution versus capsule. Compared with the fasted state, mean area under the plasma concentration–time curve from time zero to the last measurable concentration (AUC0−t) increased by 2.1- and 2.4-fold for dronabinol oral solution and capsule, respectively, when taken with food. Mean time to maximum plasma concentration was similarly delayed for dronabinol oral solution with food (7.7 hours) and capsule with food (5.6 hours) versus capsule with fasting (1.7 hours). Under fed conditions, AUC0−t and area under the plasma concentration–time curve from time zero to infinity were similar for the oral solution versus capsule based on 11-OH-Δ9-THC levels. An appreciable food effect was observed for dronabinol oral solution and capsules. Dronabinol oral solution may offer therapeutic benefit to patients, given its rapid and lower interindividual absorption variability versus dronabinol capsule. PMID:28138268
Nadeem, Hafiz Mohammad Rashid; Mohiuddin, Ejaz; UdDin, Shahab; Daniyal, Muhammad; Usmanghani, Khan
2017-01-01
Benign prostatic hyperplasia (BPH) is a disease of senile age, usually occurring> 60 years of age. BPH is a disease that involves cell proliferation of the prostate. Pathological hyperplasia affects the elements of the glandular and connective tissue of the prostate. This study is designed to scrutinize the efficacy and tolerability of herbal drug Anti BPH capsule for the management of benign prostate hyperplasia (BPH), in this study we select the 100 patients in which 50 received the Anti BPH capsule and 50 received the Terazosin HCl. We use the American Urological Association BPH Symptom Score Index Questionnaire to measure the quality of life of the patients. We compare the before treatment and after treatment results for each symptom. We record the following symptoms, incomplete emptying of bladder, Frequency, Intermittency, Urgency, Weak stream, Straining, Nocturia and weight of prostate gland by USG. We compare the both drug by using paired sample t-test. The level of significance of incomplete emptying of bladder before treatment and after treatment is 0.013 in test group and 0.032 in control group. Similarly the level of significance of Frequency before treatment and after treatment in test groups in, intermittency, Urgency, Weak stream, staining, Nocturia and mean weight of prostate gland are 0.007, 0.015, 0.044, 0.012, 0.017, 0.004 and 0.020; where as in control group afford as 0.031, 0.044, 0.044, 0.032, 0.024, 0.009 and 0.035 respectively. The herbal drug Anti BPH capsule is more effective in the treatment of BPH than Allopathic medicine Terazosin HCl.
Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans.
Rathore, Sudarshan S; Raman, Thiagarajan; Ramakrishnan, Jayapradha
2016-01-01
Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg(2+) ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg(2+) and Ca(2+). Our results on gene expression suggest that, Mg(2+) does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg(2+) ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans.
One-Dimensional Thermal Violence Cook-Off Test
NASA Astrophysics Data System (ADS)
Cook, Malcolm; Stennett, Christopher; University of Cranfield, Shrivenham, Swindon, SN6 8LA Team; AWE plc, Aldermaston, Reading Bershire, RG7 4PR, UK Team
2017-06-01
The One-Dimensional Thermal Violence (ODTV) test is designed to quantify and rank the violence of HE charges when heated to elevated temperatures. The test design consists of a central spherical explosive pellet encased in two aluminium barrel shaped halves, fitted with a copper sealing ring, encased by two aluminium locking rings placed over them from either end. The outer surface of the capsule is heated uniformly by placing in a pre-heated molten solder bath. This allows the time-to-explosion to be recorded for different initial bath temperatures. The ODTV capsule can hold samples up to 30mm in diameter. Diagnostics include both thermocouples and Photon Dopler Velocimetry (PDV). A series of live firings have been carried out on a range of bespoke HMX/HTPB explosives. These include HMX/HTPB mix ratios of 95/5, 92/8, 90/10, 88/12 and 85/15. These tests showed that the ODTV capsule had sufficient confinement and size that it could capture the spectrum of events expected from these formulations. It has been demonstrated that the deformation of the heater cup (that houses the molten solder) can be used as an additional violence metric along with the fragmentation and PDV wall velocities of the aluminium ODTV capsule.
Thermoregulation of Capsule Production by Streptococcus pyogenes
Kang, Song Ok; Wright, Jordan O.; Tesorero, Rafael A.; Lee, Hyunwoo; Beall, Bernard; Cho, Kyu Hong
2012-01-01
The capsule of Streptococcus pyogenes serves as an adhesin as well as an anti-phagocytic factor by binding to CD44 on keratinocytes of the pharyngeal mucosa and the skin, the main entry sites of the pathogen. We discovered that S. pyogenes HSC5 and MGAS315 strains are further thermoregulated for capsule production at a post-transcriptional level in addition to the transcriptional regulation by the CovRS two-component regulatory system. When the transcription of the hasABC capsular biosynthetic locus was de-repressed through mutation of the covRS system, the two strains, which have been used for pathogenesis studies in the laboratory, exhibited markedly increased capsule production at sub-body temperature. Employing transposon mutagenesis, we found that CvfA, a previously identified membrane-associated endoribonuclease, is required for the thermoregulation of capsule synthesis. The mutation of the cvfA gene conferred increased capsule production regardless of temperature. However, the amount of the capsule transcript was not changed by the mutation, indicating that a post-transcriptional regulator mediates between CvfA and thermoregulated capsule production. When we tested naturally occurring invasive mucoid strains, a high percentage (11/53, 21%) of the strains exhibited thermoregulated capsule production. As expected, the mucoid phenotype of these strains at sub-body temperature was due to mutations within the chromosomal covRS genes. Capsule thermoregulation that exhibits high capsule production at lower temperatures that occur on the skin or mucosal surface potentially confers better capability of adhesion and invasion when S. pyogenes penetrates the epithelial surface. PMID:22615992
Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive
NASA Astrophysics Data System (ADS)
Gu, Jianfa; Dai, Zhensheng; Song, Peng; Zou, Shiyang; Ye, Wenhua; Zheng, Wudi; Gu, Peijun; Wang, Jianguo; Zhu, Shaoping
2016-08-01
The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and the final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.
NASA Astrophysics Data System (ADS)
Hao, Shaojun; Sun, Youshu; Guo, Junyi; Chen, Weiliang; Wang, Hongyu; Sun, Jianhua; Guan, Zhijiang; Zhang, Zhengchen; Wang, Fang
2018-04-01
To observe the effect of Shuang Wuzhen Tong Capsule on acute toxicity of mice caused by swelling and auricular dimethylbenzene. 40 rats, weighing 18 ˜ 22G, half male and half female. Shuang Wuzhen Tong Capsule maximum concentration maximum volume to mice for 1 days by gavage for 1 times, for 7 consecutive days, to observe the situation of animal death, the maximum tolerance; the other 50 mice, were divided into 5 groups, were fed with Shuang Wuzhen Tong capsule suspension, Jingfukang granule suspension and the same volume 0.5%CMC. No death in 7 days. After death animal autopsy, heart, liver, spleen, lung, kidney, brain, stomach, intestine and no important organ obvious bleeding, hyperemia and edema, exudation, ulcer, perforation, pleural, peritoneal, pericardial cavity without effusion. Shuang Wuzhen Tong Capsule group and Jingfukang granule group could obviously reduce the xylene induced swelling of mouse ear, ear swelling degree decreased significantly (P<0.01). Shuang Wuzhen Tong Capsule has no obvious acute toxicity, anti-inflammatory effects.
Asymmetric-shell ignition capsule design to tune the low-mode asymmetry during the peak drive
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gu, Jianfa, E-mail: gu-jianfa@iapcm.ac.cn; Dai, Zhensheng, E-mail: dai-zhensheng@iapcm.ac.cn; Song, Peng
2016-08-15
The low-mode radiation flux asymmetry in the hohlraum is a main source of performance degradation in the National Ignition Facility (NIF) implosion experiments. To counteract the deleterious effects of the large positive P2 flux asymmetry during the peak drive, this paper develops a new tuning method called asymmetric-shell ignition capsule design which adopts the intentionally asymmetric CH ablator layer or deuterium-tritium (DT) ice layer. A series of two-dimensional implosion simulations have been performed, and the results show that the intentionally asymmetric DT ice layer can significantly improve the fuel ρR symmetry, hot spot shape, hot spot internal energy, and themore » final neutron yield compared to the spherical capsule. This indicates that the DT asymmetric-shell capsule design is an effective tuning method, while the CH ablator asymmetric-shell capsule could not correct the fuel ρR asymmetry, and it is not as effective as the DT asymmetric-shell capsule design.« less
Hydrocolloid liquid-core capsules for the removal of heavy-metal cations from water.
Nussinovitch, A; Dagan, O
2015-12-15
Liquid-core capsules with a non-crosslinked alginate fluidic core surrounded by a gellan membrane were produced in a single step to investigate their ability to adsorb heavy metal cations. The liquid-core gellan-alginate capsules, produced by dropping alginate solution with magnesium cations into gellan solution, were extremely efficient at adsorbing lead cations (267 mg Pb(2+)/g dry alginate) at 25 °C and pH 5.5. However, these capsules were very weak and brittle, and an external strengthening capsule was added by using magnesium cations. The membrane was then thinned with the surfactant lecithin, producing capsules with better adsorption attributes (316 mg Pb(+2)/g dry alginate vs. 267 mg Pb(+2)/g dry alginate without lecithin), most likely due to the thinner membrane and enhanced mass transfer. The capsules' ability to adsorb other heavy-metal cations - copper (Cu(2+)), cadmium (Cd(2+)) and nickel (Ni(2+)) - was tested. Adsorption efficiencies were 219, 197 and 65 mg/g, respectively, and were correlated with the cation's affinity to alginate. Capsules with the sorbed heavy metals were regenerated by placing in a 1M nitric acid suspension for 24h. Capsules could undergo three regeneration cycles before becoming damaged. Copyright © 2015 Elsevier B.V. All rights reserved.
SECM half-inch tethered endoscopic capsule (HITEC) for esophageal imaging (Conference Presentation)
NASA Astrophysics Data System (ADS)
Kang, DongKyun; Kim, Minkyu; Carruth, Robert W.; Lu, Weina; Wu, Tao; Alali, Sanaz; Do, Dukho; Soomro, Amna R.; Grant, Catriona N.; Tiernan, Aubrey R.; Rosenberg, Mireille; Nishioka, Norman S.; Tearney, Guillermo J.
2016-03-01
Spectrally encoded confocal microscopy (SECM) is a high-speed confocal endomicroscopy technology that can image extremely large regions of human tissue at cellular resolution within a short imaging time. Previously, we have developed a 7-mm-diameter SECM endoscopic capsule and successfully demonstrated imaging of human esophagus in vivo. Even though we were able to successfully capture images with the previous capsule, it suffered from two limitations: (1) the capsule had a small diameter, which provided a limited contact between SECM capsule and esophagus; and (2) speckle noise in SECM images made it challenging to appreciate cellular features. In this paper, we present a new SECM capsule, termed SECM half-inch tethered endoscopic capsule (HITEC), which addresses the two aforementioned technical challenges. With the SECM HITEC, a dual-clad fiber was used to reduce the speckle noise. Miniature GRIN optics was used to increase the NA of the fiber from 0.09 to 0.25, which made it possible to build a SECM capsule with large diameter (12.7 mm) while maintaining a short rigid length (22 mm). A water-immersion objective lens was custom designed and manufactured to provide high NA of 0.7. We have manufactured the SECM HITEC catheter and tested its optical and mechanical performance. Lateral and axial resolution was measured as 1.2 µm and 13 µm, respectively. We have imaged swine esophageal tissues ex vivo, and SECM images clearly visualized cell nuclei. Non-uniform rotational distortion (NURD) was small, less than 5%. Preliminary results suggest that SECM HITEC provides sufficient optical and mechanical performance for tissue imaging. In a future clinical study, we will test the feasibility of utilizing SECM HITEC for improved cellular imaging human of the human esophagus in vivo.
Villa, Chiara; Manzoli, Vita; Abreu, Maria M.; Verheyen, Connor A.; Seskin, Michael; Najjar, Mejdi; Molano, R. Damaris; Torrente, Yvan; Ricordi, Camillo; Tomei, Alice A.
2017-01-01
Background Understanding the effects of capsule composition and transplantation site on graft outcomes of encapsulated islets will aid in the development of more effective strategies for islet transplantation without immunosuppression. Methods Here, we evaluated the effects of transplanting alginate (ALG)-based microcapsules (Micro) in the confined and well-vascularized epididymal fat pad (EFP) site, a model of the human omentum, as opposed to free-floating in the intraperitoneal cavity (IP) in mice. We also examined the effects of reinforcing ALG with polyethylene glycol (PEG). To allow transplantation in the EFP site, we minimized capsule size to 500 ± 17 μm. Unlike ALG, PEG resists osmotic stress, hence we generated hybrid microcapsules by mixing PEG and ALG (MicroMix) or by coating ALG capsules with a 15 ± 2 μm PEG layer (Double). Results We found improved engraftment of fully allogeneic BALB/c islets in Micro capsules transplanted in the EFP (median reversal time [MRT], 1 day) versus the IP site (MRT, 5 days; P < 0.01) in diabetic C57BL/6 mice and of Micro encapsulated (MRT, 8 days) versus naked (MRT, 36 days; P < 0.01) baboon islets transplanted in the EFP site. Although in vitro viability and functionality of islets within MicroMix and Double capsules were comparable to Micro, addition of PEG to ALG in MicroMix capsules improved engraftment of allogeneic islets in the IP site, but resulted deleterious in the EFP site, probably due to lower biocompatibility. Conclusions Our results suggest that capsule composition and transplant site affect graft outcomes through their effects on nutrient availability, capsule stability, and biocompatibility. PMID:27525644
Tsangouri, E; Aggelis, D G; Van Tittelboom, K; De Belie, N; Van Hemelrijck, D
2013-01-01
Autonomous crack healing in concrete is obtained when encapsulated healing agent is embedded into the material. Cracking damage in concrete elements ruptures the capsules and activates the healing process by healing agent release. Previously, the strength and stiffness recovery as well as the sealing efficiency after autonomous crack repair was well established. However, the mechanisms that trigger capsule breakage remain unknown. In parallel, the conditions under which the crack interacts with embedded capsules stay black-box. In this research, an experimental approach implementing an advanced optical and acoustic method sets up scopes to monitor and justify the crack formation and capsule breakage of concrete samples tested under three-point bending. Digital Image Correlation was used to visualize the crack opening. The optical information was the basis for an extensive and analytical study of the damage by Acoustic Emission analysis. The influence of embedding capsules on the concrete fracture process, the location of capsule damage, and the differentiation between emissions due to capsule rupture and crack formation are presented in this research. A profound observation of the capsules performance provides a clear view of the healing activation process.
Tsangouri, E.; Aggelis, D. G.; Van Tittelboom, K.; De Belie, N.; Van Hemelrijck, D.
2013-01-01
Autonomous crack healing in concrete is obtained when encapsulated healing agent is embedded into the material. Cracking damage in concrete elements ruptures the capsules and activates the healing process by healing agent release. Previously, the strength and stiffness recovery as well as the sealing efficiency after autonomous crack repair was well established. However, the mechanisms that trigger capsule breakage remain unknown. In parallel, the conditions under which the crack interacts with embedded capsules stay black-box. In this research, an experimental approach implementing an advanced optical and acoustic method sets up scopes to monitor and justify the crack formation and capsule breakage of concrete samples tested under three-point bending. Digital Image Correlation was used to visualize the crack opening. The optical information was the basis for an extensive and analytical study of the damage by Acoustic Emission analysis. The influence of embedding capsules on the concrete fracture process, the location of capsule damage, and the differentiation between emissions due to capsule rupture and crack formation are presented in this research. A profound observation of the capsules performance provides a clear view of the healing activation process. PMID:24381518
Subsonic Dynamics of Stardust Sample Return Capsule
NASA Technical Reports Server (NTRS)
Mitcheltree, Robert A.; Fremaux, Charles M.
1997-01-01
Subsonic dynamic stability tests performed in the NASA Langley 20-Foot Vertical Spin-Tunnel on a 0.238 scale model of the Stardust Sample Return Capsule are discussed. The tests reveal that the blunted 60 degree half-angle cone capsule is dynamically unstable at low subsonic conditions due to the aft location of the center-of-gravity (0.351 body diameters back from the nose). The divergent behavior of the capsule continued when the center-of-gravity was moved to 0.337 and 0.313 body diameters back from the nose. When the center-of-gravity was moved further forward to 0.290 body diameters back from the nose, the vehicle established itself in a limit cycle with amplitude around 10 degrees. Two afterbody modifications were examined which proved unsuccessful in alleviating the instability of the original design. Finally, the addition of different sized parachutes was examined as a means to stabilize the vehicle. The parachute tests indicate that a parachute with equivalent full scale drag area of at least 2.24 ft. is necessary to assure large perturbations are damped.
Effects of secobarbital and d-amphetamine on tracking performance during angular acceleration.
DOT National Transportation Integrated Search
1973-12-01
Thirty young men were randomly assigned in equal numbers to one of the following groups: placebo (lactose), secobarbital (100 mg), or d-amphetamine (10 mg). The drugs or placebo were administered in capsules in a double-blind procedure. Tests were sc...
The effects of hematoma on implant capsules.
Caffee, H H
1986-02-01
Hematoma surrounding an implant is one of the many factors that have been suggested as possible causes for scar capsule contracture. In this study, experiments were designed to determine the influence of hematoma on the incidence and severity of capsule contracture in rabbits. Two implants were placed in each animal, 1 with a surrounding hematoma and 1 control. Capsules were evaluated subjectively and compared objectively with measurements of deformability, surface area, and capsule thickness. No differences were found with any of the objective criteria, which suggests that hematoma may not be a noteworthy cause of implant capsule contracture.
Cost effectiveness as applied to the Viking Lander systems-level thermal development test program
NASA Technical Reports Server (NTRS)
Buna, T.; Shupert, T. C.
1974-01-01
The economic aspects of thermal testing at the systems-level as applied to the Viking Lander Capsule thermal development program are reviewed. The unique mission profile and pioneering scientific goals of Viking imposed novel requirements on testing, including the development of a simulation technique for the Martian thermal environment. The selected approach included modifications of an existing conventional thermal vacuum facility, and improved test-operational techniques that are applicable to the simulation of the other mission phases as well, thereby contributing significantly to the cost effectiveness of the overall thermal test program.
Yang, X Y; Guo, C Y; Zhang, X; Zhong, Y Q; Tian, C
2017-11-28
Objective: To investigate the curative effect of Deanxit combined with Shuganjieyu capsule on the treatment of refractory gastroesophageal reflux disease. Methods: A total of 125 patients with refractory gastroesophageal reflux disease who had failed in standard lansolazole capsule treatment in the Department of Gastroenterology, First People's Hospital of Neijiang were selected. According to the symptom scores and mood scores of gastroesophageal reflux disease, patients were randomly and double-blindly divided into five groups. Group A(Lansoprazole Capsules + Mosapride Citrate + Deanxit), B(Lansoprazole Capsules + Mosapride Citrate + Shuganjieyu capsule), C(Lansoprazole Capsules + Mosapride Citrate+ Deanxit + Shuganjieyu capsule) and D(Deanxit) groups are study groups, the other was control group (Lansoprazole Capsules + Mosapride Citrate). The scores of symptoms and mood were compared after 4 weeks and 8 weeks of treatment. Results: The clinical symptoms score, HAMA and HAMD scores were significantly lower in the all study groups in comparison to the control group after 4 weeks and 8 weeks therapy. The clinical symptoms score, HAMA and HAMD scores in group C were significantly lower than those in group A and B ( P <0.05), while the difference between group A and B was not statistically significant( P >0.05). The HAMA and HAMD scores of group D were significantly higher than those of group A, B, C and control group, and the differences were statistically significant ( P <0.05). The total effective rate of study groups were significantly higher than those of the control group, and the difference was statistically significant ( P <0.05). The total effective rate of group C was significantly higher than that of group A and B (χ(2)=6.47, P <0.05). The total effective rate of group A at the end of the 8th week was significantly higher than that of group B (χ(2)=6.52, P <0.05). The total effective rate of group D at the end of the 4th and 8th week was significantly lower than those of the group A, B, C and control group, the difference was statistically significant (χ(2)=5.85, P <0.05). Conclusions: Deanxit combined with Shuganjieyu capsule is significantly effective in treatment of refractory gastroesophageal reflux disease, which can effectively improve the total treatment efficiency, reduce the symptom scores and mood scores of gastroesophageal reflux disease patients.
2011-12-02
CAPE CANAVERAL, Fla. – An Orion flight test capsule aboard the deck of NASA's Liberty Star ship is moments away from being pulled overboard into the Atlantic Ocean. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
2011-12-02
CAPE CANAVERAL, Fla. – An Orion flight test capsule makes a splash into the Atlantic Ocean as it slides from the deck of NASA's Liberty Star ship into the water. The Crew Module Recovery Attach Fitting Test (CRAFT) on the capsule, which began at-sea operations Nov. 29, is under way. Multiple attach clips are being evaluated against the current recovery cleat configuration by U.S. Air Force pararescue jumpers (PJs) and a U.S. Navy diver. The 21st Century Ground Systems Program will use data collected from the tests to help develop ground operations support equipment that could be used to recover an uncrewed Orion flight test capsule after splashdown. The Orion Multi-Purpose Crew Vehicle is NASA's next-generation spacecraft being developed for deep space missions to asteroids, moons and other interplanetary destinations throughout the solar system. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Cory Huston
Li, Kun-Yan; Liang, Jian-Ping; Hu, Bing-Qiang; Qiu, Yu; Luo, Chen-Hui; Jiang, Yun; Lin, Xiao-Ping; Yang, Nong
2010-08-01
Olmesartan medoxomil is an angiotensin II-receptor antagonist used in the treatment of hypertension. It is a prodrug and is converted to the pharmacologically active compound on de-esterification by arylesterase in the gastrointestinal tract. This study investigated the relative bioavailability and fasting pharmacokinetic properties of olmesartan after single doses of a 20-mg test tablet, a 20-mg test capsule, and a commercially available 20-mg reference tablet in healthy Chinese male volunteers. The study was conducted to satisfy Chinese State Food and Drug Administration regulatory requirements for approval of a generic formulation of olmesartan medoxomil. This study had an open-label, randomized-sequence, single-dose, 3-treatment, 3-period crossover design. Healthy volunteers were randomly assigned in a 1:1:1 ratio to receive a single 20-mg dose of the test tablet, test capsule, or reference tablet, each administered after a 12-hour overnight fast, followed by a 1-week washout period and administration of the alternate formulation. Blood samples were obtained at baseline and at 0.5, 1, 1.5,2,2.5,3,4,6,8,12,24,36, and 48 hours after dosing. Tolerability was assessed based on vital signs and laboratory values obtained before and after administration of study drug. The formulations were assumed to be bioequivalent if the 90% CIs for the log-transformed ratios of C(max), AUC(0-t), and AUC(0-∞) were within the predetermined equivalence range (70%-143% for C(max); 80%-125% for AUC(0-t) and AUC(0-∞)), as established by the Chinese State Food and Drug Administration. Twenty-one healthy male subjects (mean age, 21 years [range, 18-25 years]; weight, 62.1 kg [range, 54.0-80.0 kg]) were enrolled in and completed the study. No period or sequence effect was observed. The mean AUC(0-∞) values for the test tablet, test capsule, and reference tablet were 3993 (1070), 3567 (850), and 3849 (872) ng/mL/h, respectively. The 90% CIs for the log-transformed ratios of test tablet to reference tablet for C(max), AUC(0-48), and AUC(0-∞) were 103.9 to 124.9, 94.0 to 111.5, and 94.4 to 111.7, respectively (all, P = NS). The corresponding 90% CIs for the log-transformed ratios of test capsule to reference tablet were 90.8 to 109.2, 84.9 to 107.9, and 85.1 to 100.7 (all, P = NS). Ten adverse events were reported during the study; 7 subjects complained of pain during blood sampling, and 3 had a blocked venous catheter. No treatment-related adverse events were reported or observed. In this single-dose crossover study in healthy Chinese male volunteers, the test and reference formulations of olmesartan medoxomil 20-mg capsules and tablets met the regulatory criteria for assuming bioequivalence. The 3 formulations were well tolerated. Copyright © 2010 Excerpta Medica Inc. All rights reserved.
Hayashi, Ken; Yoshida, Motoaki; Hirata, Akira; Hayashi, Hideyuki
2011-01-01
To examine the effect of anterior capsule relaxing incisions created with a neodymium:YAG (Nd:YAG) laser on prevention of anterior capsule contraction after cataract surgery in high-risk patients. Hayashi Eye Hospital, Fukuoka, Japan. Randomized masked clinical trials. Patients at high risk for anterior capsule contraction had anterior capsule relaxing incisions in either eye 3 days postoperatively. The anterior capsule opening was measured using a Scheimpflug videophotography system (EAS-1000) immediately and 1, 3, and 6 months after capsulotomy, and the percentage reduction in area was calculated. The degree of intraocular lens (IOL) decentration and tilt, posterior capsule opacification (PCO), and other complications were also assessed. Of the 84 patients included, 30 had primary angle closure, 28 had pseudoexfoliation, and 26 had diabetic retinopathy. There was no significant difference in the mean opening area between fellow eyes at baseline. In patients with primary angle closure, the area was significantly greater and the percentage reduction in area was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0428). In patients with pseudoexfoliation or diabetic retinopathy, the percentage reduction was significantly less in the capsulotomy group than in the no-capsulotomy group (P≤.0493), although there was no significant difference in area. No significant difference was found in IOL decentration or tilt, PCO, or incidence of other complications. Neodymium:YAG laser anterior capsule relaxing incisions in the early period after cataract surgery were effective in preventing anterior capsule contraction in high-risk patients and had no adverse effects. No author has a financial or proprietary interest in any material or method mentioned. Copyright © 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Towards active capsular endoscopy: preliminary results on a legged platform.
Menciassi, Arianna; Stefanini, Cesare; Orlandi, Giovanni; Quirini, Marco; Dario, Paolo
2006-01-01
This paper illustrates the problem of active locomotion in the gastrointestinal tract for endoscopic capsules. Authors analyze the problem of locomotion in unstructured, flexible and tubular environments and explain the reasons leading to the selection of a legged system. They present a theoretical simulation of legged capsule locomotion, which is used to define the optimal parameters for capsule design and gait selection. Finally, a legged capsule--about 3 cm3 in volume--is presented; it consists of 4 back legs whose actuation is achieved thanks to a miniaturized DC brushless motor. In vitro tests demonstrate good performance in terms of achievable speed (92 mm/min).
NASA Technical Reports Server (NTRS)
Muniz, Beau
2009-01-01
One unique project that the Prototype lab worked on was PORT I (Post-landing Orion Recovery Test). PORT is designed to test and develop the system and components needed to recover the Orion capsule once it splashes down in the ocean. PORT II is designated as a follow up to PORT I that will utilize a mock up pressure vessel that is spatially compar able to the final Orion capsule.
1961-01-01
Ham, a three-year-old chimpanzee, in the spacesuit he would wear for the second Mercury- Redstone (MR-2) suborbital test flight in January, 1961. NASA used chimpanzees and other primates to test the Mercury capsule before launching the fisrt American astronaut, Alan Shepard, in May 1961. The Mercury capsule rode atop a modified Redstone rocket, developed by Dr. Wernher von Braun and the German Rocket Team in Huntsville, Alabama.
NASA Technical Reports Server (NTRS)
1961-01-01
Ham, a three-year-old chimpanzee, in the spacesuit he would wear for the second Mercury- Redstone (MR-2) suborbital test flight in January, 1961. NASA used chimpanzees and other primates to test the Mercury capsule before launching the fisrt American astronaut, Alan Shepard, in May 1961. The Mercury capsule rode atop a modified Redstone rocket, developed by Dr. Wernher von Braun and the German Rocket Team in Huntsville, Alabama.
Magnesium Ion Acts as a Signal for Capsule Induction in Cryptococcus neoformans
Rathore, Sudarshan S.; Raman, Thiagarajan; Ramakrishnan, Jayapradha
2016-01-01
Cryptococcal meningitis caused by Cryptococcus neoformans, is a common opportunistic neural infection in immunocompromised individuals. Cryptococcus meningitis is associated with fungal burden with larger capsule size in cerebrospinal fluid (CSF). To understand the role of CSF constituents in capsule enlargement, we have evaluated the effect of artificial CSF on capsule induction in comparison with various other capsule inducing media. Two different strains of C. neoformans, an environmental and a clinical isolates were used in the present study. While comparing the various capsule inducing media for the two different strains of C. neoformans, it was observed that the capsule growth was significantly increased when grown in artificial CSF at pH 5.5, temperature 34°C for ATCC C. neoformans and 37°C for Clinical C. neoformans and with an incubation period of 72 h. In addition, artificial CSF supports biofilm formation in C. neoformans. While investigating the individual components of artificial CSF, we found that Mg2+ ions influence the capsule growth in both environmental and clinical strains of C. neoformans. To confirm our results we studied the expression of four major CAP genes namely, CAP10, CAP59, CAP60, and CAP64 in various capsule inducing media and in different concentrations of Mg2+ and Ca2+. Our results on gene expression suggest that, Mg2+ does have an effect on CAP gene expression, which are important for capsule biosynthesis and virulence. Our findings on the role of Mg2+ ion as a signal for capsule induction will promote a way to elucidate the control mechanisms for capsule biosynthesis in C. neoformans. PMID:27014245
2012-09-20
CAPE CANAVERAL, Fla. - NASA Aerospace Engineer Jeff Hagen prepares a model capsule ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida to test a rotor system landing design. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
Underway Recovery Test 6 (URT-6) - Day 4 Afternoon Activities
2018-01-20
Chief Warrant Officer Ferrari from the USS Anchorage inspects the Deck Department as they prepare to bring in “Oscar,” a dummy used for man overboard drills. During Underway Recovery Test 6, the USS Anchorage’s man overboard drill gave Kennedy Space Center’s NASA Recovery Team a glimpse of one way an astronaut could be brought from a small boat onto the ship using a stretcher. Once the Orion capsule splashes down in the Pacific Ocean, astronauts can choose to stay in the capsule until it is pulled into the well deck of the Navy vessel, or have a diver retrieve them first and then get the capsule later.
Recovery of the Little Joe 5A spacecraft
1961-03-18
S61-01398 (18 March 1961) --- View of the recovery of the Little Joe-5A spacecraft which lifted off on March 18, 1961 from Wallops Island. The photo was taken from the recovery helicopter and shows the craft's parachute still attached and floating in the water next to the capsule. Little Joe-5A was a suborbital flight to test the Mercury capsule. The escape rocket motor fired prematurely and prior to capsule release. Photo credit: NASA
A modular and programmable development platform for capsule endoscopy system.
Khan, Tareq Hasan; Shrestha, Ravi; Wahid, Khan A
2014-06-01
The state-of-the-art capsule endoscopy (CE) technology offers painless examination for the patients and the ability to examine the interior of the gastrointestinal tract by a noninvasive procedure for the gastroenterologists. In this work, a modular and flexible CE development system platform consisting of a miniature field programmable gate array (FPGA) based electronic capsule, a microcontroller based portable data recorder unit and computer software is designed and developed. Due to the flexible and reprogrammable nature of the system, various image processing and compression algorithms can be tested in the design without requiring any hardware change. The designed capsule prototype supports various imaging modes including white light imaging (WLI) and narrow band imaging (NBI), and communicates with the data recorder in full duplex fashion, which enables configuring the image size and imaging mode in real time during examination. A low complexity image compressor based on a novel color-space is implemented inside the capsule to reduce the amount of RF transmission data. The data recorder contains graphical LCD for real time image viewing and SD cards for storing image data. Data can be uploaded to a computer or Smartphone by SD card, USB interface or by wireless Bluetooth link. Computer software is developed that decompresses and reconstructs images. The fabricated capsule PCBs have a diameter of 16 mm. An ex-vivo animal testing has also been conducted to validate the results.
SITE TECHNOLOGY CAPSULE: GEOTECH DEVELOPMENT CORPORATION COLD TOP EX-SITU VITRIFICATION TECHNOLOGY
A SITE technology demonstration was conducted in 1997 to evaluate the potential applicability and effectiveness of the Geotech Cold Top ex-situ vitrification technology on chromium-contaminated soils. The primary objective was to develop test data to evaluate whether the waste a...
AGR-3/4 Irradiation Test Train Disassembly and Component Metrology First Look Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stempien, John Dennis; Rice, Francine Joyce; Harp, Jason Michael
2016-03-01
The AGR-3/4 experiment was designed to study fission product transport within graphitic matrix material and nuclear-grade graphite. To this end, this experiment consisted of 12 capsules, each fueled with 4 compacts containing UCO TRISO particles as driver fuel and 20 UCO designed-to-fail (DTF) fuel particles in each compact. The DTF fuel was fabricated with a thin pyrocarbon layer which was intended to fail during irradiation and provide a source of fission products. These fission products could then migrate through the compact and into the surrounding concentric rings of graphitic matrix material and/or nuclear graphite. Through post-irradiation examination (PIE) of themore » rings (including physical sampling and gamma scanning) fission product concentration profiles within the rings can be determined. These data can be used to elucidate fission product transport parameters (e.g. diffusion coefficients within the test materials) which will be used to inform and refine models of fission product transport. After irradiation in the Advanced Test Reactor (ATR) had been completed in April 2014, the AGR-3/4 experiment was shipped to the Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) for inspection, disassembly, and metrology. The AGR-3/4 test train was received at MFC in two separate shipments between February and April 2015. Visual examinations of the test train exterior did not indicate dimensional distortion, and only two small discolored areas were observed at the bottom of Capsules 8 and 9. No corresponding discoloration was found on the inside of these capsules, however. Prior to disassembly, the two test train sections were subject to analysis via the Precision Gamma Scanner (PGS), which did not indicate that any gross fuel relocation had occurred. A series of specialized tools (including clamps, cutters, and drills) had been designed and fabricated in order to carry out test train disassembly and recovery of capsule components (graphite rings and fuel compacts). This equipment performed well for separating each capsule in the test train and extracting the capsule components. Only a few problems were encountered. In one case, the outermost ring (the sink ring) was cracked during removal of the capsule through tubes. Although the sink ring will be analyzed in order to obtain a mass balance of fission products in the experiment, these cracks do not pose a major concern because the sink ring will not be analyzed in detail to obtain the spatial distribution of fission products. In Capsules 4 and 5, the compacts could not be removed from the inner rings. Strategies for removing the compacts are being evaluated. Sampling the inner rings with the compacts in-place is also an option. Dimensional measurements were made on the compacts, inner rings, outer rings, and sink rings. The diameters of all compacts decreased by 0.5 to 2.0 %. Generally, the extent of diametric shrinkage increased linearly with increasing neutron fluence. Most compact lengths also decreased. Compact lengths decreased with increasing fluence, reaching maximum shrinkage of about 0.9 % at a fast fluence of 4.0x10 25 n/m 2 E > 0.18 MeV. Above this fluence, the extent of length shrinkage appeared to decrease with fluence, and two compacts from Capsule 7 were found to have slightly increased in length (< 0.1 %) after a fluence of 5.2x10 25 n/m 2.« less
AGR-3/4 Irradiation Test Train Disassembly and Component Metrology First Look Report
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stempien, John Dennis; Rice, Francine Joyce; Harp, Jason Michael
The AGR-3/4 experiment was designed to study fission product transport within graphitic matrix material and nuclear-grade graphite. To this end, this experiment consisted of 12 capsules, each fueled with 4 compacts containing UCO TRISO particles as driver fuel and 20 UCO designed-to-fail (DTF) fuel particles in each compact. The DTF fuel was fabricated with a thin pyrocarbon layer which was intended to fail during irradiation and provide a source of fission products. These fission products could then migrate through the compact and into the surrounding concentric rings of graphitic matrix material and/or nuclear graphite. Through post-irradiation examination (PIE) of themore » rings (including physical sampling and gamma scanning) fission product concentration profiles within the rings can be determined. These data can be used to elucidate fission product transport parameters (e.g. diffusion coefficients within the test materials) which will be used to inform and refine models of fission product transport. After irradiation in the Advanced Test Reactor (ATR) had been completed in April 2014, the AGR-3/4 experiment was shipped to the Hot Fuel Examination Facility (HFEF) at the Materials and Fuels Complex (MFC) for inspection, disassembly, and metrology. The AGR-3/4 test train was received at MFC in two separate shipments between February and April 2015. Visual examinations of the test train exterior did not indicate dimensional distortion, and only two small discolored areas were observed at the bottom of Capsules 8 and 9. No corresponding discoloration was found on the inside of these capsules, however. Prior to disassembly, the two test train sections were subject to analysis via the Precision Gamma Scanner (PGS), which did not indicate that any gross fuel relocation had occurred. A series of specialized tools (including clamps, cutters, and drills) had been designed and fabricated in order to carry out test train disassembly and recovery of capsule components (graphite rings and fuel compacts). This equipment performed well for separating each capsule in the test train and extracting the capsule components. Only a few problems were encountered. In one case, the outermost ring (the sink ring) was cracked during removal of the capsule through tubes. Although the sink ring will be analyzed in order to obtain a mass balance of fission products in the experiment, these cracks do not pose a major concern because the sink ring will not be analyzed in detail to obtain the spatial distribution of fission products. In Capsules 4 and 5, the compacts could not be removed from the inner rings. Strategies for removing the compacts are being evaluated. Sampling the inner rings with the compacts in-place is also an option. Dimensional measurements were made on the compacts, inner rings, outer rings, and sink rings. The diameters of all compacts decreased by 0.5 to 2.0 %. Generally, the extent of diametric shrinkage increased linearly with increasing neutron fluence. Most compact lengths also decreased. Compact lengths decreased with increasing fluence, reaching maximum shrinkage of about 0.9 % at a fast fluence of 4.0x1025 n/m2 E > 0.18 MeV. Above this fluence, the extent of length shrinkage appeared to decrease with fluence, and two compacts from Capsule 7 were found to have slightly increased in length (< 0.1 %) after a fluence of 5.2x1025 n/m2.« less
AGR-3/4 Irradiation Test Predictions using PARFUME
DOE Office of Scientific and Technical Information (OSTI.GOV)
Skerjanc, William Frances; Collin, Blaise Paul
2016-03-01
PARFUME, a fuel performance modeling code used for high temperature gas reactors, was used to model the AGR-3/4 irradiation test using as-run physics and thermal hydraulics data. The AGR-3/4 test is the combined third and fourth planned irradiations of the Advanced Gas Reactor (AGR) Fuel Development and Qualification Program. The AGR-3/4 test train consists of twelve separate and independently controlled and monitored capsules. Each capsule contains four compacts filled with both uranium oxycarbide (UCO) unaltered “driver” fuel particles and UCO designed-to-fail (DTF) fuel particles. The DTF fraction was specified to be 1×10-2. This report documents the calculations performed to predictmore » failure probability of TRISO-coated fuel particles during the AGR-3/4 experiment. In addition, this report documents the calculated source term from both the driver fuel and DTF particles. The calculations include the modeling of the AGR-3/4 irradiation that occurred from December 2011 to April 2014 in the Advanced Test Reactor (ATR) over a total of ten ATR cycles including seven normal cycles, one low power cycle, one unplanned outage cycle, and one Power Axial Locator Mechanism cycle. Results show that failure probabilities are predicted to be low, resulting in zero fuel particle failures per capsule. The primary fuel particle failure mechanism occurred as a result of localized stresses induced by the calculated IPyC cracking. Assuming 1,872 driver fuel particles per compact, failure probability calculated by PARFUME leads to no predicted particle failure in the AGR-3/4 driver fuel. In addition, the release fraction of fission products Ag, Cs, and Sr were calculated to vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 7 reaching up to 56% for the driver fuel and 100% for the DTF fuel. The release fraction of the other two fission products, Cs and Sr, are much smaller and in most cases less than 1% for the driver fuel. The notable exception occurs in Capsule 7 where the release fraction for Cs and Sr reach up to 0.73% and 2.4%, respectively, for the driver fuel. For the DTF fuel in Capsule 7, the release fraction for Cs and Sr are estimated to be 100% and 5%, respectively.« less
Fischer, Sebastian; Hirche, Christoph; Diehm, Yannick; Nuutila, Kristo; Kiefer, Jurij; Gazyakan, Emre; Bueno, Ericka M; Kremer, Thomas; Kneser, Ulrich; Pomahac, Bohdan
2016-01-01
The fibrotic capsule that surrounds silicone implants consists mainly of collagen. The FDA-approved collagenase of the bacterium clostridium histolyticum provides a reasonable treatment option. Safety and efficacy at the female breast site must be evaluated before clinical utilization. We incubated 20 samples of fibrotic capsule as well as 12 full thickness skin grafts harvested from the female breast site for 24 hours with different doses of collagenase. Outcome measures involved histological assessment of thickness and density of the capsule tissue as well as the skin grafts. Furthermore, we performed a collagen assay and immunohistochemistry staining for collagen subtypes. Collagenase treatment was able to degrade human capsule contracture tissue ex-vivo. The remaining collagen subtype after degradation was type 4 only. 0.3 mg/ml of collagenase was most effective in reducing capsule thickness when compared with higher concentrations. Of note, effectiveness was inversely related to capsule density, such that there was less reduction in thickness with higher capsule densities and vice versa. Furthermore, the application of 0.3mg/ml collagenase did not lead to thinning or perforation of full thickness skin grafts. Adjustment of collagenase dose will depend on thickness and density of the contracted capsule. A concentration of 0.3mg/ml seems to be safe and effective in an ex-vivo setting. The remaining collagen subtype 4 is suitable to serve as a neo-capsule/acellular tissue matrix. Collagenase treatment for capsular contracture may soon become a clinical reality.
2008-01-24
NASA Dryden technicians work on a fit-check mockup in preparation for systems installation work on an Orion boilerplate crew capsule for launch abort testing. A mockup Orion crew module has been constructed by NASA Dryden Flight Research Center's Fabrication Branch. The mockup is being used to develop integration procedures for avionics and instrumentation in advance of the arrival of the first abort flight test article.
2008-01-24
NASA Dryden technicians take measurements inside a fit-check mockup for prior to systems installation on a boilerplate Orion launch abort test crew capsule. A mockup Orion crew module has been constructed by NASA Dryden Flight Research Center's Fabrication Branch. The mockup is being used to develop integration procedures for avionics and instrumentation in advance of the arrival of the first abort flight test article.
Microencapsulation of 2-octylcyanoacrylate tissue adhesive for self-healing acrylic bone cement.
Brochu, Alice B W; Chyan, William J; Reichert, William M
2012-10-01
Here, we report the first phase of developing self-healing acrylic bone cement: the preparation and characterization of polyurethane (PUR) microcapsules containing a medical cyanoacrylate tissue adhesive. Capsules were prepared by interfacial polymerization of a toluene-2,4-diisocyanate-based polyurethane prepolymer with 1,4-butanediol to encapsulate 2-octylcyanoacrylate (OCA). Various capsule characteristics, including: resultant morphology, average size and size distribution, shell thickness, content and reactivity of encapsulated agent, and shelf life are investigated and their reliance on solvent type and amount, surfactant type and amount, temperature, pH, agitation rate, reaction time, and mode of addition of the oil phase to the aqueous phase are presented. Capsules had average diameters ranging from 74 to 222 μm and average shell thicknesses ranging from 1.5 to 6 μm. The capsule content was determined via thermogravimetric analysis and subsequent analysis of the capsules following up to 8 weeks storage revealed minimal loss of core contents. Mechanical testing of OCA-containing capsules showed individual capsules withstood compressive forces up to a few tenths of Newtons, and the contents released from crushed capsules generated tensile adhesive forces of a few Newtons. Capsules were successfully mixed into the poly(methyl methacrylate) bone cement, surviving the mixing process, exposure to methyl methacrylate monomer, and the resulting exothermic matrix curing. Copyright © 2012 Wiley Periodicals, Inc.
NASA Astrophysics Data System (ADS)
Singh, Rajesh; Sarkar, Kausik
2012-11-01
Deformability of red blood cells affects hydrodynamic properties of blood and thereby physiological functions in many cardiovascular diseases, e.g. in sickle cell anemia and malaria, the cell membrane becomes stiff affecting their circulation through microvessels. Here, we numerically simulate the hydrodynamic interaction between a pair of cell-like capsules in a free shear flow, using a front-tracking method. The membrane is modeled using various constitutive equations. By varying the stiffness of one capsule (C2) and keeping all other parameters constant, we find a significant effect on the deformation and trajectory of the other (C1) . Increasing the stiffness of C2 surprisingly increases the peak deformation of C1 while decreasing the cross-stream shift in its trajectory However, the relative trajectory between capsules remains the same. Effects of constitutive laws and difference in behaviors between capsules and drops are investigated explaining underlying physics. partial support from NSF.
Boar semen controlled delivery system: storage and in vitro spermatozoa release.
Torre, M L; Faustini, M; Norberti, R; Stacchezzini, S; Maggi, L; Maffeo, G; Conte, U; Vigo, D
2002-12-13
Swine spermatozoa were encapsulated in barium alginate and protamine-barium alginate membranes to lengthen their preservation time and to provide a means of controlling their release. Precocious acrosome reactions and secondary anomalies were measured as indices of semen quality. These characteristics were observed for two forms of encapsulated spermatozoa when stored at 18 and 38 degrees C for 24 h and for semen diluted in a classical extender at both temperatures. The results indicate that encapsulation enhances semen preservation, providing protection against membrane damage upon dilution. The effect is even more evident at the higher temperature (38 degrees C), where cell metabolism is higher. An in vitro release test of spermatozoa showed a massive cell delivery from barium alginate capsules within 6 h, and a slow release from protamine-barium alginate capsules. The properties of spermatozoa 24 h after release did not differ from the semen stored at the same temperature in capsules, indicating that the release process does not impair semen quality.
Popovski, N; Popovski, K; Nedelkovski, V
2016-01-01
Vaginal infections /VI/ represent some of the most common diseases by infection of FGS. The aim of this study is to analyze clinical and bacteriological efficacy of Polygynax in the treatment of vaginal infections and to take into account the correlation between the results of microbiological controls and reduction of clinical symptoms. The study included 100 patients, including 50 pregnant and non-pregnant 50 for a period of 3 months. All of them was diagnosed with vaginitis clinical examination, taken material from vagina for microbiological testing. The studied women was conducted targeted therapy Polygynax 12 capsules, in the form of vaginal capsules for 12 days, after which the sample control microbiology. Behind the subjective complaints of the patient and to reduce them as a result of treatment. The effective implementation of Polygynax 12 capsules is equally good as in non-pregnant and pregnant women. In a summary of the survey data to make relevant analyzes and conclusions from the results.
Design options for reducing the impact of the fill-tube in ICF implosion experiments on the NIF
NASA Astrophysics Data System (ADS)
Weber, Christopher R.; Berzak Hopkins, L. F.; Casey, D. T.; Clark, D. S.; Hammel, B. A.; Le Pape, S.; Macphee, A.; Milovich, J.; Pickworth, L. A.; Robey, H. F.; Smalyuk, V. A.; Stadermann, M.; Felker, S. J.; Nikroo, A.; Thomas, C. A.; Crippen, J.; Rice, N.
2017-10-01
Inertial Confinement Fusion (ICF) capsules on the National Ignition Facility (NIF) are filled with thermonuclear fuel through a fill-tube. When the capsule implodes, perturbations caused by the fill-tube allow ablator material to mix into the hot spot and reduce fusion performance. This talk will explore several design options that attempt to reduce this damaging effect. Reducing the diameter of the fill-tube and its entrance hole is the obvious course and has been tested in experiments. Simulations also show sensitivity to the amount of glue holding the fill-tube to the capsule and suggest that careful control of this feature can limit the amount of injected mass. Finally, an off-axis fill-tube reduces the initial squirt of material into the fuel and may be a way of further optimizing this engineering feature. Work performed under the auspices of the U.S. D.O.E. by Lawrence Livermore National Laboratory under Contract No. DE-AC52-07NA27344.
Yang, J-D; Kwon, O-H; Lee, J-W; Chung, H-Y; Cho, B-C; Park, H-Y; Kim, T-G
2013-01-01
Capsular contracture is one of the most severe complications that can occur in breast surgery following silicone implant insertion. The purpose of this study was to investigate the effect of montelukast and antiadhesion barrier solution (AABS) on reducing capsular formation and their possible synergism. This study was approved by the Animal Ethics Committee (Reference No. KNU 2012-33) and was conducted in accordance with the Kyungpook National University - Institutional Animal Care and Use Committee, Animal Ethics Committee. The experiments in this study were conducted in vivo in 4 groups of 24 rats. Following silicone implant insertion, the pocket was injected with different agents. Group I (control group) was given normal saline injections into the pocket and fed with pure water. Group II was given injections of AABS and fed with pure water. Group III was given injections of normal saline and the medication montelukast during the experimental period. Group IV was given injections of AABS and montelukast as postoperative medication. Peri-implant capsules were excised after 8 weeks and were evaluated for transparency, inflammatory cell content, capsule thickness, collagen pattern and TGF-β expression. The capsules in the experimental groups (i.e., groups II-IV) were significantly more transparent than those in group I (controls; p < 0.05, Student's t test). The mean capsule thickness of the experimental groups II (296 ± 14.76 μm), III (280 ± 14.77 μm) and IV (276 ± 39.28 μm) was smaller than that of the control group I (361 ± 35.43 μm). Compared to the control group, the histologic findings in the experimental groups suggested a decreased inflammatory response occurring in the peri-implant capsules as they exhibited minor vascularization and a reduced number of mast cells and macrophages. The collagen patterns in the experimental groups were of a lower density than in the control group with the former showing a loose, tidy collagen pattern. The amounts of TGF-β and collagen I were higher in the control group than in the experimental groups. Group IV (the synergic effect group) had a more pronounced effect on all the parameters examined than that in groups II and III with separate drug administration. Montelukast and AABS reduced the thickness, the inflammatory cell infiltrate and the myofibroblast content of the peri-implant capsules around silicone implants in this white rat model. They lowered the expression of the fibrotic mediator, TGF-β, and inhibited the peri-implant capsular fibrosis. Therefore, montelukast and AABS are effective in the reduction of silicone-induced peri-implant capsular formation.
Sándor, Gábor L; Kiss, Zoltán; Bocskai, Zoltán I; Kolev, Krasimir; Takács, Ágnes I; Juhász, Éva; Kránitz, Kinga; Tóth, Gábor; Gyenes, Andrea; Bojtár, Imre; Juhász, Tibor; Nagy, Zoltán Z
2015-03-01
To evaluate and compare the mechanical properties of anterior capsule opening performed with femtosecond laser capsulotomy at different energy settings in ex vivo porcine anterior lens capsule specimens. Twenty-five fresh porcine eyes per group were included in the study. Femtosecond laser capsulotomy was performed with three different pulse energy levels: 2 µJ (low energy group), 5 µJ (intermediate energy group), and 10 µJ (high energy group). The capsule openings were stretched with universal testing equipment until they ruptured. The morphologic profile of the cut capsule edges was evaluated using scanning electron microscopy. The high energy group had significantly lower rupture force (108 ± 14 mN) compared to the intermediate energy group (118 ± 10 mN) (P < .05) and low energy group (119 ± 11 mN) (P < .05), but the difference between the intermediate energy and low energy groups was not significant (P = .9479). The high energy group had significantly lower circumference stretching ratio (144% ± 3%) compared to the intermediate energy group (148% ± 3%) (P < .05) and low energy group (148% ± 3%) (P < .05), but the difference between the intermediate energy group and low energy group was not significant (P = .9985). Scanning electron microscopy images showed that the edge was only serrated with low and intermediate energy, but additional signs of collagen melting and denaturation were observed at high energy. Anterior capsule openings created at a high energy level were slightly weaker and less extensible than those created at low or intermediate levels, possibly due to the increased thermal effect of photo-disruption. Copyright 2015, SLACK Incorporated.
State diagram for adhesion dynamics of deformable capsules under shear flow.
Luo, Zheng Yuan; Bai, Bo Feng
2016-08-17
Due to the significance of understanding the underlying mechanisms of cell adhesion in biological processes and cell capture in biomedical applications, we numerically investigate the adhesion dynamics of deformable capsules under shear flow by using a three-dimensional computational fluid dynamic model. This model is based on the coupling of the front tracking-finite element method for elastic mechanics of the capsule membrane and the adhesion kinetics simulation for adhesive interactions between capsules and functionalized surfaces. Using this model, three distinct adhesion dynamic states are predicted, such as detachment, rolling and firm-adhesion. Specifically, the effects of capsule deformability quantified by the capillary number on the transitions of these three dynamic states are investigated by developing an adhesion dynamic state diagram for the first time. At low capillary numbers (e.g. Ca < 0.0075), whole-capsule deformation confers the capsule a flattened bottom in contact with the functionalized surface, which hence promotes the rolling-to-firm-adhesion transition. It is consistent with the observations from previous studies that cell deformation promotes the adhesion of cells lying in the rolling regime. However, it is surprising to find that, at relatively high capillary numbers (e.g. 0.0075 < Ca < 0.0175), the effect of capsule deformability on its adhesion dynamics is far more complex than just promoting adhesion. High deformability of capsules makes their bottom take a concave shape with no adhesion bond formation in the middle. The appearance of this specific capsule shape inhibits the transitions of both rolling-to-firm-adhesion and detachment-to-rolling, and it means that capsule deformation no longer promotes the capsule adhesion. Besides, it is interesting to note that, when the capillary number exceeds a critical value (e.g. Ca = 0.0175), the rolling state no longer appears, since capsules exhibit large deviation from the spherical shape.
Onset of Labor in Post-Term Pregnancy by Chamomile.
Gholami, Fereshte; Neisani Samani, Leila; Kashanian, Maryam; Naseri, Mohsen; Hosseini, Agha Fateme; Hashemi Nejad, Seyed Abbas
2016-11-01
Post-term pregnancy is an important factor in perinatal mortality and morbidity. Generally, to reduce perinatal mortality in pregnancy, the delivery is done before adverse perinatal morbidity occurs. To prevent prolonged pregnancy, labor is induced with chemical drugs and complementary therapies. Due to the side effects and contraindications of chemical medicine, the use of herbs has been investigated in the induction of labor in post-term pregnancy. This study was done to identify the effect of chamomile on inducing labor in women with post-term pregnancy of Shahid Akbarabadi hospital in Tehran in 2013. This double-blind clinical trial study was performed in Iran on 80 post-term pregnant women with a gestational age of 40 weeks or more, a single pregnancy, 18 - 35 years old, cephalic presentation, an estimated fetal weight of 2500 - 4000 grams, an absence of uterine contraction, a cervical Bishop score of less than 4, the safety of the membrane, and low-risk pregnancy; they were randomly assigned to one of two groups of 40 women. Each of the participants was given a bottle containing 42 capsules (500 mg each) and took 2 capsules every 8 hours. The data were collected through the questionnaire of demographic observational, and examinal characteristics. Descriptive statistics, independent samples t-test, and Fisher's exact test using SPSS (16/win) were used to determine and compare the effects of drugs on inducing labor in the groups. After a week of using the first dose, the results showed that in 92.5% of the chamomile group and 62.5% in the placebo group, delivery symptoms started after taking the oral capsules, and there were significant statistical differences between the two groups for the onset of labor (P = 0.003) There was a noticeable statistical difference between the two groups regarding the mean interval time to the onset of labor pain after taking the capsules (P = 0.000). In this study¸ chamomile stimulated labor in post-term pregnancy. With further studies, chamomile, which has no chemical side effects, can be suggested for stimulating labor in post-term pregnancy.
Onset of Labor in Post-Term Pregnancy by Chamomile
Gholami, Fereshte; Neisani Samani, Leila; Kashanian, Maryam; Naseri, Mohsen; Hosseini, Agha Fateme; Hashemi Nejad, Seyed Abbas
2016-01-01
Background Post-term pregnancy is an important factor in perinatal mortality and morbidity. Generally, to reduce perinatal mortality in pregnancy, the delivery is done before adverse perinatal morbidity occurs. To prevent prolonged pregnancy, labor is induced with chemical drugs and complementary therapies. Due to the side effects and contraindications of chemical medicine, the use of herbs has been investigated in the induction of labor in post-term pregnancy. Objectives This study was done to identify the effect of chamomile on inducing labor in women with post-term pregnancy of Shahid Akbarabadi hospital in Tehran in 2013. Patients and Methods This double-blind clinical trial study was performed in Iran on 80 post-term pregnant women with a gestational age of 40 weeks or more, a single pregnancy, 18 - 35 years old, cephalic presentation, an estimated fetal weight of 2500 - 4000 grams, an absence of uterine contraction, a cervical Bishop score of less than 4, the safety of the membrane, and low-risk pregnancy; they were randomly assigned to one of two groups of 40 women. Each of the participants was given a bottle containing 42 capsules (500 mg each) and took 2 capsules every 8 hours. The data were collected through the questionnaire of demographic observational, and examinal characteristics. Descriptive statistics, independent samples t-test, and Fisher’s exact test using SPSS (16/win) were used to determine and compare the effects of drugs on inducing labor in the groups. Results After a week of using the first dose, the results showed that in 92.5% of the chamomile group and 62.5% in the placebo group, delivery symptoms started after taking the oral capsules, and there were significant statistical differences between the two groups for the onset of labor (P = 0.003) There was a noticeable statistical difference between the two groups regarding the mean interval time to the onset of labor pain after taking the capsules (P = 0.000). Conclusions In this study¸ chamomile stimulated labor in post-term pregnancy. With further studies, chamomile, which has no chemical side effects, can be suggested for stimulating labor in post-term pregnancy. PMID:28210497
Zhou, Chunhua; Su, Linfei; Shang, Weiding; Rong, Zhihuan; Sun, Mengmeng; Zhang, Kai; Shi, Xiaowei; Wang, Qiao
2015-01-01
A rapid, sensitive, selective and periodic polarity-switching liquid chromatography-tandem mass spectrometry(LC-MS-MS) method was developed for the simultaneous determination of eight components in an important traditional Chinese medicinal capsule, Fufang Xueshuantong. LC analysis was carried out on a Kinetex 2.6 µm XB-C18 column by gradient elution. The detection was performed by multiple reaction monitoring (MRM) with a periodic polarity-switching electrospray ionization (ESI) source across five periods of switching between positive and negative mode. Periodic polarity-switching was used to acquire maximal responses and to simultaneously detect eight constituents in one analysis run lasting 8 min. All of the analytes showed good linearity (r > 0.9947) in the tested ranges. The average recoveries were in the range of 95.4-103.9% with relative standard deviations ≤6.3%, and the intra- and inter-day variations were ≤3.7%. The developed method was successfully employed to analyze three batches of Fufang Xueshuantong capsule samples. The results showed that the levels of notoginsenoside R1, ginsenoside Rb1 and salvianolic acid B were clearly different in different batches of Fufang Xueshuantong capsules. Furthermore, the new established periodic polarity-switching LC-MS-MS method was proven to be highly sensitive and effective in evaluating the quality of Fufang Xueshuantong capsules. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Aerodynamic Challenges for the Mars Science Laboratory Entry, Descent and Landing
NASA Technical Reports Server (NTRS)
Schoenenberger, Mark; Dyakonov, Artem; Buning, Pieter; Scallion, William; Norman, John Van
2009-01-01
An overview of several important aerodynamics challenges new to the Mars Science Laboratory (MSL) entry vehicle are presented. The MSL entry capsule is a 70 degree sphere cone-based on the original Mars Viking entry capsule. Due to payload and landing accuracy requirements, MSL will be flying at the highest lift-to-drag ratio of any capsule sent to Mars (L/D = 0.24). The capsule will also be flying a guided entry, performing bank maneuvers, a first for Mars entry. The system's mechanical design and increased performance requirements require an expansion of the MSL flight envelope beyond those of historical missions. In certain areas, the experience gained by Viking and other recent Mars missions can no longer be claimed as heritage information. New analysis and testing is re1quired to ensure the safe flight of the MSL entry vehicle. The challenge topics include: hypersonic gas chemistry and laminar-versus-turbulent flow effects on trim angle, a general risk assessment of flying at greater angles-of-attack than Viking, quantifying the aerodynamic interactions induced by a new reaction control system and a risk assessment of recontact of a series of masses jettisoned prior to parachute deploy. An overview of the analysis and tests being conducted to understand and reduce risk in each of these areas is presented. The need for proper modeling and implementation of uncertainties for use in trajectory simulation has resulted in a revision of prior models and additional analysis for the MSL entry vehicle. The six degree-of-freedom uncertainty model and new analysis to quantify roll torque dispersions are presented.
NASA Astrophysics Data System (ADS)
Lv, Zhong; Chen, Huisu
2014-10-01
Autonomous healing of cracks using pre-embedded capsules containing healing agent is becoming a promising approach to restore the strength of damaged structures. In addition to the material properties, the size and volume fraction of capsules influence crack healing in the matrix. Understanding the crack and capsule interaction is critical in the development and design of structures made of self-healing materials. Assuming that the pre-embedded capsules are randomly dispersed we theoretically model flat ellipsoidal crack interaction with capsules and determine the probability of a crack intersecting the pre-embedded capsules i.e. the self-healing probability. We also develop a probabilistic model of a crack simultaneously meeting with capsules and catalyst carriers in two-component self-healing system matrix. Using a risk-based healing approach, we determine the volume fraction and size of the pre-embedded capsules that are required to achieve a certain self-healing probability. To understand the effect of the shape of the capsules on self-healing we theoretically modeled crack interaction with spherical and cylindrical capsules. We compared the results of our theoretical model with Monte-Carlo simulations of crack interaction with capsules. The formulae presented in this paper will provide guidelines for engineers working with self-healing structures in material selection and sustenance.
Primate Ham - Fitted Suit - Couch - Mercury-Redstone (MR)-2 - Capsule #5
1961-01-23
S63-20801 (23 Jan. 1961) --- Primate chimpanzee ?Ham?, in his spacesuit, is fitted into the couch of the Mercury-Redstone 2 (MR-2) capsule #5 prior to its test flight which was conducted on Jan. 31, 1961. Photo credit: NASA
Experimental Investigation of Shock Initiation in Mixtures of Manganese and Sulfur
NASA Astrophysics Data System (ADS)
Jetté, F. X.; Goroshin, S.; Higgins, A. J.
2009-12-01
Equimolar mixtures of manganese powder and sulfur at different starting densities were tested in two different types of steel recovery capsules in order to study the shock initiation phenomenon in Self-Propagating High-Temperature Synthesis (SHS) mixtures. Two different sizes of Mn particles were used for these experiments, <10 μm and -325 mesh (<44 μm). This mixture was selected due to the large exothermic heat release of the manganese-sulfur reaction (214 kJ/mol), which causes the reaction to be self-sustaining once initiated. The test samples were placed in planar recovery capsules and a strong shock was delivered via the detonation of a charge of amine-sensitized nitromethane. Various shock strengths were achieved by placing different thicknesses of PMMA attenuator discs between the explosive charge and the capsule. The results confirmed that shock-induced reactions can be produced in highly non-porous mixtures. It was also found that shock interactions with the side walls of the recovery capsule can play a significant role in the initiation.
[Effect of Fuzheng Huayu capsules on survival rate of patients with liver cirrhosis].
Ge, X J; Zhao, C Q; Xu, L M
2017-11-20
Objective: To investigate the effect of Fuzheng Huayu capsules on the survival rate of patients with liver cirrhosis. Methods: A retrospective analysis was performed for the clinical data of the patients with various types of liver cirrhosis who were hospitalized in Shuguang Hospital Affiliated to Shanghai University of Traditional Chinese Medicine from January 1, 2006 to December 31, 2008. The data collected for these patients included their basic information, diagnosis and treatment, and results of laboratory examination. The Kaplan-Meier method was used to analyze the effect of Fuzheng Huayu capsules on the survival rate of patients with liver cancer. The starting point of observation was the first day of the patient's admission and the ending point of follow-up observation was the date of death or the end of follow-up April 1, 2014. The cut-off value was obtained if the patient did not experience any outcome event (death) at the end of follow-up. With reference to the outcome, the time when the outcome occurred, and the cut-off value, the life-table method was used to calculate survival rates and survival curves were plotted. The Kaplan-Meier product-limit method was used to calculate the arithmetic mean of survival time and median survival time, and the log-rank test was used to compare the survival data. Results: A total of 430 patients with liver cirrhosis were enrolled, among whom 191 died and 239 survived or were censored. The average constituent ratio of death was 55.6% and the average constituent ratio of survival was 44.4%. The life-table method showed that the half-, 1-, 2-, and 5-year survival rates were 70%, 64%, 58%, and 48%, respectively. The median survival time was 112.1 weeks for the patients who did not take Fuzheng Huayu capsules and 351.6 weeks for those who did, and there was a significant difference in survival rate between the two groups ( P = 0.000). Among 313 patients who had an etiology of hepatitis B, 164 did not take Fuzheng Huayu capsules and had a median survival time of 195.9 weeks and a 5-year survival rate of 44%, and 149 took Fuzheng Huayu capsules and had a median survival time of 336.9 weeks and a 5-year survival rate of 59%; there was a significant difference in survival rate between the two groups ( P = 0.038). Among 117 patients who did not have hepatitis B, 68 did not take Fuzheng Huayu capsules and had a median survival time of 78.1 weeks and a 5-year survival rate of 32%, and 49 took Fuzheng Huayu capsules and had a median survival time of 277.4 weeks and a 5-year survival rate of 53%; there was a significant difference in survival rate between the two groups ( P = 0.013). Among 92 patients with compensated liver cirrhosis, 47 did not take Fuzheng Huayu capsules and had a 5-year survival rate of 65%, and 45 took Fuzheng Huayu capsules and had a 5-year survival rate of 82%; both groups of patients had a median survival of 440 weeks; there was a significant difference in survival rate between the two groups ( P = 0.027). Among 338 patients with decompensated liver cirrhosis, 185 did not take Fuzheng Huayu capsules and had a median survival time of 60.3 weeks and a 5-year survival rate of 33%, and 153 took Fuzheng Huayu capsules and had a median survival time of 267.7 weeks and a 5-year survival rate of 51%; there was a significant difference in survival rate between the two groups ( P = 0.001). Conclusion: Fuzheng Huayu capsules can improve the prognosis of patients with liver cirrhosis and increase their survival rates and have good long-term efficacy.
Buttini, Francesca; Pasquali, Irene; Brambilla, Gaetano; Copelli, Diego; Alberi, Massimiliano Dagli; Balducci, Anna Giulia; Bettini, Ruggero; Sisti, Viviana
2016-03-01
The aim of this work was to evaluate the effect of two different dry powder inhalers, of the NGI induction port and Alberta throat and of the actual inspiratory profiles of asthmatic patients on in-vitro drug inhalation performances. The two devices considered were a reservoir multidose and a capsule-based inhaler. The formulation used to test the inhalers was a combination of formoterol fumarate and beclomethasone dipropionate. A breath simulator was used to mimic inhalatory patterns previously determined in vivo. A multivariate approach was adopted to estimate the significance of the effect of the investigated variables in the explored domain. Breath simulator was a useful tool to mimic in vitro the in vivo inspiratory profiles of asthmatic patients. The type of throat coupled with the impactor did not affect the aerodynamic distribution of the investigated formulation. However, the type of inhaler and inspiratory profiles affected the respirable dose of drugs. The multivariate statistical approach demonstrated that the multidose inhaler, released efficiently a high fine particle mass independently from the inspiratory profiles adopted. Differently, the single dose capsule inhaler, showed a significant decrease of fine particle mass of both drugs when the device was activated using the minimum inspiratory volume (592 mL).
Jaafarpour, Molouk; Hatefi, Masoud; Khajavikhan, Javaher
2015-01-01
Background and Aims Primary dysmenorrheal has a negative impact on women's quality of life. The purpose of this study was to compare the effect of Cinnamon and Ibuprofen for treatment of primary dysmenorrheal in a sample of Iranian female college students from Ilam University of Medical Sciences (western Iran). Materials and Methods In a randomized, double-blind trial, out of 114, control group received placebo (empty capsules contain starch, TDS, n= 38) a test group received Ibuprofen (capsule containing 400mg Ibuprofen, TDS, n=38), or another test group received Cinnamon (capsule containing 420 mg Cinnamon, TDS, n= 38) in 24 h. To determine severity of pain, we used the VAS scale. Pain intensity and duration of pain were monitored in the group during first 72 h of cycle. Results The mean pain severity score and mean duration of pain in Ibuprofen and Cinnamon were less than placebo group respectively (p< 0.001). Of 4 hours after the intervention there were no statistically significant differences between the Cinnamon and placebo group (p> 0.05). Of eight hours after the intervention, the mean pain severity in the cinnamon group was significantly lower than placebo group (p< 0.001). At various time intervals the mean pain severity in the Ibuprofen group were significantly less than Cinnamon and placebo groups (p< 0.001). Conclusion Cinnamon compared with placebo significantly reduced the severity and duration of pain during menstruation, but this effect was lower compared with Ibuprofen. Cinnamon can be regarded as a safe and effective treatment for primary dysmenorrhea. More researches are recommended to study the efficacy of Cinnamon on reducing menstrual bleeding. PMID:26023601
Gralnek, I M; Adler, S N; Yassin, K; Koslowsky, B; Metzger, Y; Eliakim, R
2008-04-01
Esophageal capsule endoscopy (ECE) provides an alternative, minimally invasive modality for evaluating the esophagus. This study evaluates the performance and test characteristics of a second-generation esophageal capsule endoscope, the PillCam ESO 2. Adults with known or suspected esophageal disease were included. Using the simplified ingestion procedure, each patient underwent capsule endoscopy with the PillCam ESO 2. Following ECE, esophagogastroduodenoscopy (EGD) was performed on the same day by an investigator who was blinded to the results of the ECE. In random order, capsule endoscopy videos were read and interpreted by the study investigator blinded to EGD results. 28 patients (19 men, 9 women; mean age 53.3 years) were included. In 82 % of the patients, at least 75 % of the Z line was visualized by the PillCam ESO 2. A per-lesion analysis demonstrated that the PillCam ESO 2 had definitive results in 30/43 lesions (69.8 %) and EGD in 29/43 (67.4 %), P value = 0.41. Compared with EGD for detecting suspected Barrett's esophagus and esophagitis, the PillCam ESO 2 had a sensitivity of 100 % and a specificity of 74 %, and a sensitivity of 80 % and a specificity of 87 %, respectively. The PillCam ESO 2 demonstrated 86 % agreement with EGD in describing the Z line (kappa statistic 0.68). The modified ingestion protocol provided excellent cleansing, with bubbles/saliva having no or only a minor effect on Z line images in 86 % of cases. The PillCam ESO 2 demonstrated excellent visualization of the Z line. Compared with standard EGD, the PillCam ESO 2 had good test characteristics with high rates of detection of suspected Barrett's esophagus and esophagitis. This study provides indirect validation of the simplified ingestion procedure. The PillCam ESO 2 acquires high quality esophageal images, performs safely, and should be able to replace the current PillCam ESO.
Infrared Observations of the Orion Capsule During EFT-1 Hypersonic Reentry
NASA Technical Reports Server (NTRS)
Horvath, Thomas J.; Rufer, Shann J.; Schuster, David M.; Mendeck, Gavin F.; Oliver, A. Brandon; Schwartz, Richard J.; Verstynen, Harry A.; Mercer, C. David; Tack, Steven; Ingram, Ben;
2016-01-01
High-resolution infrared observations of the Orion capsule during its atmospheric reentry on December 5, 2015 were made from a US Navy NP-3D. This aircraft, equipped with a long-range optical sensor system, tracked the capsule from Mach 10 to 7 from a distance of approximately 60 nmi. Global surface temperatures of the capsule's thermal heatshield were derived from near infrared intensity measurements. The global surface temperature measurements complemented onboard instrumentation and were invaluable to the interpretation of the in-depth thermocouple measurements which rely on inverse heat transfer methods and material response codes to infer the desired surface temperature from the sub-surface measurements. The full paper will address the motivations behind the NASA Engineering Safety Center sponsored observation and highlight premission planning processes with an emphasis on aircraft placement, optimal instrument configuration and sensor calibrations. Critical aspects of mission operations coordinated from the NASA Johnson Spaceflight Center and integration with the JSC Flight Test Management Office will be discussed. A summary of the imagery that was obtained and processed to global surface temperature will be presented. At the capsule's point of closest approach relative to the imaging system, the spatial resolution was estimated to be approximately 15-inches per pixel and was sufficient to identify localized temperature increases associated with compression pad support hardware on the heatshield. The full paper will discuss the synergy of the quantitative imagery derived temperature maps with in-situ thermocouple measurements. Comparison of limited onboard surface thermocouple data to the image derived surface temperature will be presented. The two complimentary measurements serve as an example of the effective leveraging of resources to advance the understanding of high Mach number environments associated with an ablated heatshield and provide unique data for the validation of design tools and numerical flight simulation techniques. Collaborative opportunities and technology investments in support of planned observations of NASA's next Orion flight test in 2018 will be explored in the full manuscript.
Reactions of dipolar bio-molecules in nano-capsules--example of folding-unfolding process.
Sanfeld, A; Sefiane, K; Steinchen, A
2011-11-14
The confinement of chemical reactions in nano-capsules can lead to a dramatic effect on the equilibrium constant of these latter. Indeed, capillary effects due to the curvature and surface energy of nano-capsules can alter in a noticeable way the evolution of reactions occurring within. Nano-encapsulation of bio-materials has attracted lately wide interest from the scientific community because of the great potential of its applications in biomedical areas and targeted therapies. The present paper focuses one's attention on alterations of conformation mechanisms due to extremely confining and interacting solvated dipolar macromolecules at their isoelectric point. As a specific example studied here, the folding-unfolding reaction of proteins (particularly RNase A and creatine kinase CK) is drastically changed when encapsulated in solid inorganic hollow nano-capsules. The effects demonstrated in this work can be extended to a wide variety of nano-encapsulation situations. The design and sizing of nano-capsules can even make use of the effects shown in the present study to achieve better and more effective encapsulation. Copyright © 2011 Elsevier B.V. All rights reserved.
Albumin/asparaginase capsules prepared by ultrasound to retain ammonia.
Tinoco, Ana; Ribeiro, Artur; Oliveira, César; Parpot, Pier; Gomes, Andreia; Cavaco-Paulo, Artur
2016-11-01
Asparaginase reduces the levels of asparagine in blood, which is an essential amino acid for the proliferation of lymphoblastic malign cells. Asparaginase converts asparagine into aspartic acid and ammonia. The accumulation of ammonia in the bloodstream leads to hyperammonemia, described as one of the most significant side effects of asparaginase therapy. Therefore, there is a need for asparaginase formulations with the potential to reduce hyperammonemia. We incorporated 2 % of therapeutic enzyme in albumin-based capsules. The presence of asparaginase in the interface of bovine serum albumin (BSA) capsules showed the ability to hydrolyze the asparagine and retain the forming ammonia at the surface of the capsules. The incorporation of Poloxamer 407 in the capsule formulation further increased the ratio aspartic acid/ammonia from 1.92 to 2.46 (and 1.10 from the free enzyme), decreasing the levels of free ammonia. This capacity to retain ammonia can be due to electrostatic interactions and retention of ammonia at the surface of the capsules. The developed BSA/asparaginase capsules did not cause significant cytotoxic effect on mouse leukemic macrophage cell line RAW 264.7. The new BSA/asparaginase capsules could potentially be used in the treatment of acute lymphoblastic leukemia preventing hyperammonemia associated with acute lymphoblastic leukemia (ALL) treatment with asparaginase.
El Massik, M A; Abdallah, O Y; Galal, S; Daabis, N A
2003-05-01
Seven semisolid fill bases were selected for the formulation of 24 capsule formulations, each containing 100 mg of phenytoin sodium. The fill materials were selected based on the water absorption capacity of their mixtures with phenytoin sodium. The fill matrices included lipophilic bases (castor oil, soya oil, and Gelucire (G) 33/01), amphiphilic bases (G 44/14 and Suppocire BP), and water-soluble bases (PEG 4000 and PEG 6000). The drug:base ratio was 1:2. Excipients such as lecithin, docusate sodium, and poloxamer 188 were added to some formulations. The dissolution rate study indicated that formulations containing lipophilic and amphiphilic bases showed the best release profiles. These are F4 (castor oil-1% docusate sodium); F10 (castor oil-3% poloxamer 188); F14 (G33/01-10% lecithin); F17 (G33/01-1% docusate sodium), and F20 (Suppocire BP). Further, the dissolution stability of the five formulations above was assessed by an accelerated stability study at 30 degrees C and 75% RH using standard Epanutin capsules for comparison. The study included the test and standard capsules either packed in the container of marketed Epanutin capsules (packed) or removed from their outer pack (unpacked). Release data indicated superior release rates of castor oil based formulations (F4 and F10) relative to standard capsules in both the unpacked and packed forms. For instance, the extent of drug release at 30 min after 1 month was 91% for F4 and F10 and 20% for standard capsules. Drug release from packed capsules after 6 months storage was 88% for both formulations F4 and F10 and 35% for standard capsules. In conclusion, the pharmaceutical quality of phenytoin sodium capsules can be improved by using a semisolid lipophilic matrix filled in hard gelatin capsules.
Kitagawa, Yuichi; Yasuki, Tsuyoshi; Hasegawa, Junji
2006-11-01
Many efforts have been made to understand the mechanism of whiplash injury. Recently, the cervical facet joint capsules have been focused on as a potential site of injury. An experimental approach has been taken to analyze the vertebral motion and to estimate joint capsule stretch that was thought to be a potential cause of pain. The purpose of this study is to analyze the kinematics of the cervical facet joint using a human FE model in order to better understand the injury mechanism. The Total Human Model for Safety (THUMS) was used to visually analyze the local and global kinematics of the spine. Soft tissues in the neck were newly modeled and introduced into THUMS for estimating the loading level in rear impacts. The model was first validated against human test data in the literature by comparing vertebrae motion as well as head and neck responses. Joint capsule strain was estimated from a maximum principal strain output from the elements representing the capsule tissues. A rear-end collision was then simulated using THUMS and a prototype seat model, assuming a delta-V of 25 km/h. The trajectory of the vertebrae was analyzed in a local coordinate system defined along the joint surface. Strain growth in the joint capsules was explained, as related to contact events between the occupant and the seat. A new seat concept was proposed to help lessen the loading level to the neck soft tissues. The foam material of the seat back was softened, the initial gap behind the head was reduced and the head restraint was stiffened for firm support. The lower seat back frame was also reinforced to withstand the impact severity at the given delta-V. Another rear impact simulation was conducted using the new seat concept model to examine the effectiveness of the new concept. The joint capsule strain was found to be relatively lower with the new seat concept. The study also discusses the influence of seat parameters to the vertebral motion and the resultant strain in the joint capsules. The meaning of the contact timing of the head to the head restraint was examined based on the results in terms of correlation with injury indicators such as NIC and the joint capsule strain.
Oxygen fugacity and piston cylinder capsule assemblies
NASA Astrophysics Data System (ADS)
Jakobsson, S.
2011-12-01
A double capsule assembly designed to control oxygen fugacity in piston cylinder experiments has been tested at 1200 °C and 10 kbar. The assembly consists of an outer Pt-capsule containing a solid buffer (Ni-NiO or Co-CoO plus H2O) and an inner AuPd-capsule containing the sample, H2O and a Pt-wire. To prevent direct contact with the buffer phases the AuPd-capsule is embedded in finely ground Al2O3 along with some coarser, fractured Al2O3 facilitating fluid inclusion formation. No water loss is observed in the sample even after 48 hrs but a slight increase in water content is observed in longer duration runs due to oxygen and hydrogen diffusion into the AuPd-capsule. Carbon from the furnace also diffuses through the outer Pt-capsule but reacts with H2O in the outer capsule to form CO2 and never reaches the inner capsule. Oxygen fugacity of runs in equilibrium with the Ni-NiO and Co-CoO buffers was measured by analyzing the Fe content of the Pt-wire in the sample1 and by analyzing Fe dissolved in the AuPd capsule2. The second method gives values that are in good agreement with established buffer whereas results from the first method are one half to one log units higher than the established values. References 1. E. Medard, C. A. McCammon, J. A. Barr, T. L. Grove, Am. Mineral. 93, 1838 (2008). 2. J. Barr, T. Grove, Contrib. Mineral. Petrol. 160, 631 (2010)
Shape memory alloy-based biopsy device for active locomotive intestinal capsule endoscope.
Le, Viet Ha; Hernando, Leon-Rodriguez; Lee, Cheong; Choi, Hyunchul; Jin, Zhen; Nguyen, Kim Tien; Go, Gwangjun; Ko, Seong-Young; Park, Jong-Oh; Park, Sukho
2015-03-01
Recently, capsule endoscopes have been used for diagnosis in digestive organs. However, because a capsule endoscope does not have a locomotive function, its use has been limited to small tubular digestive organs, such as small intestine and esophagus. To address this problem, researchers have begun studying an active locomotive intestine capsule endoscope as a medical instrument for the whole gastrointestinal tract. We have developed a capsule endoscope with a small permanent magnet that is actuated by an electromagnetic actuation system, allowing active and flexible movement in the patient's gut environment. In addition, researchers have noted the need for a biopsy function in capsule endoscope for the definitive diagnosis of digestive diseases. Therefore, this paper proposes a novel robotic biopsy device for active locomotive intestine capsule endoscope. The proposed biopsy device has a sharp blade connected with a shape memory alloy actuator. The biopsy device measuring 12 mm in diameter and 3 mm in length was integrated into our capsule endoscope prototype, where the device's sharp blade was activated and exposed by the shape memory alloy actuator. Then the electromagnetic actuation system generated a specific motion of the capsule endoscope to extract the tissue sample from the intestines. The final biopsy sample tissue had a volume of about 6 mm(3), which is a sufficient amount for a histological analysis. Consequently, we proposed the working principle of the biopsy device and conducted an in-vitro biopsy test to verify the feasibility of the biopsy device integrated into the capsule endoscope prototype using the electro-magnetic actuation system. © IMechE 2015.
Computer-Based Assessments. Information Capsule. Volume 0918
ERIC Educational Resources Information Center
Blazer, Christie
2010-01-01
This Information Capsule reviews research conducted on computer-based assessments. Advantages and disadvantages associated with computer-based testing programs are summarized and research on the comparability of computer-based and paper-and-pencil assessments is reviewed. Overall, studies suggest that for most students, there are few if any…
Boeing's Dart and Starliner Parachute System Test
2018-02-22
Boeing conducted the first in a series of reliability tests of its CST-100 Starliner flight drogue and main parachute system by releasing a long, dart-shaped test vehicle from a C-17 aircraft over Yuma, Arizona. Two more tests are planned using the dart module, as well as three similar reliability tests using a high fidelity capsule simulator designed to simulate the CST-100 Starliner capsule’s exact shape and mass. In both the dart and capsule simulator tests, the test spacecraft are released at various altitudes to test the parachute system at different deployment speeds, aerodynamic loads, and or weight demands. Data collected from each test is fed into computer models to more accurately predict parachute performance and to verify consistency from test to test.
Pedro, M R A; Madriaga, J R; Barba, C V C; Habito, R C F; Gana, A E; Deitchler, M; Mason, J B
2004-12-01
The prevalence of vitamin A deficiency (serum retinol [SR] < 20 microg/dl) in children from one to five years of age in the Philippines rose from 35.8% to 38% between 1993 and 1998, despite a twice-yearly universal vitamin A capsule distribution program. The Philippines 1998 National Nutrition Survey, with one-time SR measurements from 11,620 children from one to four years of age, collected over an eight-month period from one month to more than six months after distribution of vitamin A capsules, was an opportunity to examine the impact of the program on the children's vitamin A status, using post hoc analysis. Overall, a detectable impact of vitamin A capsules on SR was limited to groups with the highest prevalence of vitamin A deficiency and lasted up to four months after dose administration. In highly urban cities in Visayas, where very high prevalences of deficient SR (SR < 10 microg/dl) were found, the prevalence of deficient SR was reduced from 27% to 9% one to two months after distribution of vitamin A capsules, and to 16% at three to four months. In Mindanao, a statistically significant reduction from 38% to 32% was seen in the prevalence of deficient to low SR (SR < 20 microg/dl) one to four months after distribution of vitamin A capsules. There was no overall reduction in the prevalence of vitamin A deficiency or deficient and low SR (SR < 20 microg/dl) in Luzon, but a significant interaction with stunting was observed in Luzon non-highly urbanized cities. Two aspects are of concern. First, the magnitude of the effect of high-dose vitamin A capsules on SR, and hence on the extent of reduction in deficiency, is limited. Second, the effect does not persist for six months, which is the interval between doses. Thus there is no decrease in the prevalence of deficiency over time. With more frequent dosing (especially to those most deficient in SR), a progressive reduction in vitamin A deficiency could, however, be expected; this hypothesis could be tested. The policy implication arising from these results is that a shift in resources is warranted. In areas of low prevalence of vitamin A deficiency, distribution of vitamin A capsules should be targeted to stunted children. In areas of high prevalence, vitamin A capsules should be distributed to children one to five years old at least three times a year.
Lu, Hailin; Ren, Shanshan; Li, Xing; Guo, Junde; Dong, Guangneng; Li, Jianhui; Gao, Li
2018-08-01
Body fluid is normally the only lubricant after joint replacement surgery, but wear problems have occurred because body fluid has poor lubrication ability. However, traditional lubricant would be diluted by body fluids and then absorbed by the human body. Therefore, an injectable gel with the ability to slow-release lubricant was designed to replace the joint capsule. The proposed gel, poly(ethylene glycol)/chitosan/sodium glycerophosphate (PEG/CS/GP) composite gel was then tested. The tribology results showed that the PEG/CS/GP gel had excellent slow-release properties, especially under pressure, and the PEG played an important role in improving the gel's rheological and mechanical properties. Moreover, this study revealed that the release solution had a good lubrication effect because the PEG and GP could crosslink via the hydrogen bond effect.
Trépanier, C; Leung, T K; Tabrizian, M; Yahia, L H; Bienvenu, J G; Tanguay, J F; Piron, D L; Bilodeau, L
1999-01-01
Nickel-titanium (NiTi) offers many advantages for the fabrication of coronary stents: shape memory, superelasticity, and radiopacity. However, many authors highlighted the selective dissolution of Ni from the alloy during the corrosion process that could lead to potential toxicity. The improvement of the NiTi stent's corrosion resistance by different surface treatments (electropolishing, heat treatment, and nitric acid passivation) was reported in a previous article. In the present study a comparative biocompatibility evaluation of such stents was performed through in vitro and in vivo assays. A cell proliferation test was completed to evaluate the cytotoxicity of surface treated NiTi using human fibroblasts. Then a stent implantation was performed in rabbit paramuscular muscle to study the inflammatory response generated by the same implants. Cell proliferation tests generally indicated an in vitro biocompatibility of our samples similar to the control group. An in vivo implantation study demonstrated the gradual overall reduction with time of the fibrocellular capsule thickness surrounding the implants. After a 12-week implantation period, the fibrous capsules surrounding the different implants tended toward the same value of 0.07 mm, which suggested that all surface treatments produced a similar biological response. This low value of the fibrocellular capsule indicated that our NiTi surface treated implants were relatively inert.
Biointerfacing polymeric microcapsules for in vivo near-infrared light-triggered drug release
NASA Astrophysics Data System (ADS)
Shao, Jingxin; Xuan, Mingjun; Si, Tieyan; Dai, Luru; He, Qiang
2015-11-01
Seeking safe and effective water-soluble drug carriers is of great significance in nanomedicine. To achieve this goal, we present a novel drug delivery system based on biointerfacing hollow polymeric microcapsules for effectively encapsulating water-soluble antitumor drug and gold nanorod (GNR) functionalization for triggered release of therapeutic drugs on-demand using low power near-infrared (NIR) radiation. The surface of polymeric microcapsules is covered with fluidic lipid bilayers to decrease the permeability of the wall of polymeric capsules. The temperature increase upon NIR illumination deconstructs the structure of the lipid membrane and polyelectrolyte multilayers, which in turn results in the rapid release of encapsulated water-soluble drug. In vivo antitumor tests demonstrate that this microcapsule has the effective ability of inhibiting tumor growth and preventing metastases. Real time in vivo fluorescence imaging results confirm that capsules can be excreted gradually from the animal body which in turn demonstrates the biocompatibility and biodegradation of these biointerfacing GNR-microcapsules. This intelligent system provides a novel anticancer platform with the advantages of controlled release, biological friendliness and credible biosafety.Seeking safe and effective water-soluble drug carriers is of great significance in nanomedicine. To achieve this goal, we present a novel drug delivery system based on biointerfacing hollow polymeric microcapsules for effectively encapsulating water-soluble antitumor drug and gold nanorod (GNR) functionalization for triggered release of therapeutic drugs on-demand using low power near-infrared (NIR) radiation. The surface of polymeric microcapsules is covered with fluidic lipid bilayers to decrease the permeability of the wall of polymeric capsules. The temperature increase upon NIR illumination deconstructs the structure of the lipid membrane and polyelectrolyte multilayers, which in turn results in the rapid release of encapsulated water-soluble drug. In vivo antitumor tests demonstrate that this microcapsule has the effective ability of inhibiting tumor growth and preventing metastases. Real time in vivo fluorescence imaging results confirm that capsules can be excreted gradually from the animal body which in turn demonstrates the biocompatibility and biodegradation of these biointerfacing GNR-microcapsules. This intelligent system provides a novel anticancer platform with the advantages of controlled release, biological friendliness and credible biosafety. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06350g
Comparative analysis of EPA and DHA in fish oil nutritional capsules by GC-MS.
Yi, Tao; Li, Shuk-Man; Fan, Jia-Yi; Fan, Lan-Lan; Zhang, Zhi-Feng; Luo, Pei; Zhang, Xiao-Jun; Wang, Jian-Gang; Zhu, Lin; Zhao, Zhong-Zhen; Chen, Hu-Biao
2014-12-13
Fish oil is a popular nutritional product consumed in Hong Kong. Eicosapentaenoic acid (EPA) and docosahexaenoic acid (DHA) are the two main bioactive components responsible for the health benefits of fish oil. Market survey in Hong Kong demonstrated that various fish oil capsules with different origins and prices are sold simultaneously. However, these capsules are labelled with same ingredient levels, namely EPA 180 mg/g and DHA 120 mg/g. This situation makes the consumers very confused. To evaluate the quality of various fish oil capsules, a comparative analysis of the contents of EPA and DHA in fish oil is crucial. A gas chromatography-mass spectrometry (GC-MS) method was developed for identification and determination of EPA and DHA in fish oil capsules. A comprehensive validation of the developed method was conducted. Ten batches of fish oil capsules samples purchased from drugstores of Hong Kong were analyzed by using the developed method. The present method presented good sensitivity, precision and accuracy. The limits of detection (LOD) for EPA and DHA were 0.08 ng and 0.21 ng, respectively. The relative standard deviation (RSD) values of EPA and DHA for repeatability tests were both less than 1.05%; and the recovery for accuracy test of EPA and DHA were 100.50% and 103.83%, respectively. In ten fish oil samples, the contents of EPA ranged from 39.52 mg/g to 509.16 mg/g, and the contents of DHA ranged from 35.14 mg/g to 645.70 mg/g. The present method is suitable for the quantitative analysis of EPA and DHA in fish oil capsules. There is a significant variation in the contents of the quantified components in fish oil samples, and there is not a linear relationship between price and contents of EPA and DHA. Strict supervision of the labelling of the fish oil capsules is urgently needed.
NASA Astrophysics Data System (ADS)
Magelssen, G. R.; Bradley, P. A.; Tregillis, I. L.; Schmitt, M. J.; Dodd, E. S.; Wysocki, F. J.; Hsu, S. C.; Cobble, J.; Batha, S. H.; Defriend Obrey, K. A.
2010-11-01
Small capsule perturbations may impact our ability to achieve high yields on NIF. Diagnosing the hydrodynamic development and the effect of defects on burn will be difficult. Los Alamos is developing a program to better understand the hydrodynamics of defects and how they influence burn. Our first effort to study the effects of defects was on Omega. Both thin-shelled (exploding pusher) and thick-shelled capsules were shot and the results published [1]. In this work we add experimental shots done recently on Omega. These shots were to complete the study of how the width and depth of the defect affects DT yield. Our AMR code is used to predict the yield. Comparisons between capsule and experimental yields will be given. Experiments are also being designed for Polar direct drive. Our first experiments are being designed to understand the zero-order hydrodynamics with Polar direct drive. Capsules about a millimeter in radius are being designed with one to two dopants in the CH shell for radiograph and MMI usage. Also, to minimize the effect of mix on the radius versus time trajectory, some capsules will replace the DT with Xe.[0pt] [1] Magelssen G. R. et al., to be published in the 2009 IFSA proceedings.
Intestinal biomechanics simulator for robotic capsule endoscope validation.
Slawinski, Piotr R; Oleynikov, Dmitry; Terry, Benjamin S
2015-01-01
This work describes the development and validation of a novel device which simulates important forces experienced by Robotic Capsule Endoscopes (RCE) in vivo in the small intestine. The purpose of the device is to expedite and lower the cost of RCE development. Currently, there is no accurate in vitro test method nor apparatus to validate new RCE designs; therefore, RCEs are tested in vivo at a cost of ∼$1400 per swine test. The authors have developed an in vitro RCE testing device which generates two peristaltic waves to accurately simulate the two biomechanical actions of the human small intestine that are most relevant to RCE locomotion: traction force and contact force. The device was successfully calibrated to match human physiological ranges for traction force (4-40 gf), contact force (80-500 gf) and peristaltic wave propagation speed (0.08-2 cm s(-1)) for a common RCE capsule geometry of 3.5 cm length and 1.5 cm diameter.
Development and Testing of a Magnetically Actuated Capsule Endoscopy for Obesity Treatment
Do, Thanh Nho; Seah, Tian En Timothy; Yu, Ho Khek; Phee, Soo Jay
2016-01-01
Intra-gastric balloons (IGB) have become an efficient and less invasive method for obesity treatment. The use of traditional IGBs require complex insertion tools and flexible endoscopes to place and remove the balloon inside the patient’s stomach, which may cause discomfort and complications to the patient. This paper introduces a new ingestible weight-loss capsule with a magnetically remote-controlled inflatable and deflatable balloon. To inflate the balloon, biocompatible effervescent chemicals are used. As the source of the actuation is provided via external magnetic fields, the magnetic capsule size can be significantly reduced compared to current weight-loss capsules in the literature. In addition, there are no limitations on the power supply. To lose weight, the obese subject needs only to swallow the magnetic capsule with a glass of water. Once the magnetic capsule has reached the patient’s stomach, the balloon will be wirelessly inflated to occupy gastric space and give the feeling of satiety. The balloon can be wirelessly deflated at any time to allow the magnetic capsule to travel down the intestine and exit the body via normal peristalsis. The optimal ratio between the acid and base to provide the desired gas volume is experimentally evaluated and presented. A prototype capsule (9.6mm x 27mm) is developed and experimentally validated in ex-vivo experiments. The unique ease of delivery and expulsion of the proposed magnetic capsule is slated to make this development a good treatment option for people seeking to lose excess weight. PMID:26815309
Zhang, Quan Bing; Zhou, Yun; Zhong, Hua Zhang; Liu, Yi
2018-05-01
The aim of this study was to investigate the therapeutic effect of stretching combined with ultrashort wave on joint contracture and explore its possible mechanism. Thirty-two rabbits underwent unilateral immobilization of a knee joint at full extension to cause joint contracture. At 6 wks after immobilization, the rabbits were randomly divided into the following four groups: natural recovery group, stretching treatment group, ultrashort wave treatment group, and combined treatment group. For comparison, eight control group animals of corresponding age were also examined. The effect of stretching and ultrashort wave treatment on joint contracture was assessed by measuring the joint range of motion, evaluating the collagen deposition of joint capsule and assessing the mRNA and protein levels for transforming growth factor β1 in the joint capsule. The combined treatment group led to the best recovery of joint function. The combined treatment with stretching and ultrashort wave was more effective than stretching or ultrashort wave treatment alone against the synovial thickening of suprapatellar joint capsule, the collagen deposition of anterior joint capsule, and the elevated expression of transforming growth factor β1 in the joint capsule. Stretching combined with ultrashort wave treatment was effective in improving joint range of motion, reducing the biomechanical, histological, and molecular manifestations of joint capsule fibrosis in a rabbit model of extending joint contracture.
Giraldez, E. M.; Hoppe Jr., M. L.; Hoover, D. E.; ...
2016-07-07
Hydrodynamic instability growth and its effects on capsule implosion performance are being studied at the National Ignition Facility (NIF). Experimental results have shown that low-mode instabilities are the primary culprit for yield degradation. Ignition type capsules with machined 2D sinusoidal defects were used to measure low-mode hydrodynamic instability growth in the acceleration phase of the capsule implosion. The capsules were imploded using ignition-relevant laser pulses and the ablation-front modulation growth was measured using x-ray radiography. The experimentally measured growth was in good agreement with simulations.
Chen, Feng-Jing; Etzler, Frank M; Ubben, Johanna; Birch, Amy; Zhong, Li; Schwabe, Robert; Dudhedia, Mayur S
2010-01-01
The present study investigated the effect of lipophilic components on the compatibility of propylene glycol (PG)-containing lipid-based drug delivery system (LBDDS) formulations with hard gelatin capsules. The presence of a lipophilic active pharmaceutical ingredient (API) (log P approximately 6.1) and an additional lipophilic excipient (Capmul MCM) significantly affected the activity of PG in the fills and the equilibrium of PG between capsule shells and fills. These changes in activity and equilibrium of PG were furthermore correlated to the mechanical and thermal properties of the liquid-filled capsules and subsequently linked to the shelf-life of the capsules on stability with respect to capsule deformation. The present study also investigated the mechanism by which lipophilic component(s) might affect the activity of PG in the fill formulations and the equilibrium of PG between capsule shells and fills. The activities of PG in two series of "binary" mixtures with Capmul MCM and with Cremophor EL were measured, respectively. The mixtures of PG containing Capmul MCM were found to be more nearly ideal than those containing Cremophor EL. The observed negative deviation from Rauolt's law indicates that the excess free energies of mixing are less then zero indicating favorable interaction between PG and the other component. It is speculated that enhanced hydrogen bonding opportunities with Cremophor EL are responsible for the decreased excess free energy of mixing. Replacement of Cremophor EL with lipophilic API also reduces the hydrogen bonding opportunities for PG in the mixtures. This hypothesis may further explain the increased activity of PG in the fills and the shifted equilibrium of PG toward the capsule shells. Activity determination utilizing headspace gas chromatography (GC) using short 30 min incubation time seems to be a time-efficient approach for assessing capsule-fill compatibility. Direct measurements of PG migration and other physical properties of the capsules took much longer time (7 weeks) for ranking the predicted capsule deformation at 40 degrees C. Asides from the time savings, activity determination can be considered to be material sparing by offering capsule-fill compatibility assessment even without the need for preparing liquid-filled capsules once appropriate positive and negative references are established. With further optimization, this approach should enable high throughput screening of LBDDS for capsule-fill compatibility in liquid-filled capsule development.
The Impact of School Buildings on Learning. Information Capsule. Volume 1204
ERIC Educational Resources Information Center
Blazer, Christie
2012-01-01
This Information Capsule examines the impact of deteriorating school buildings on students and teachers. Research indicates that students attending schools that are in poor physical condition score lower on achievement tests than students in newer, functional buildings. Studies suggest that several specific factors contribute to lower levels of…
Effect of anterior capsule contraction on visual function after cataract surgery.
Hayashi, Ken; Hayashi, Hideyuki
2007-11-01
To examine the effect of contraction of the anterior capsule opening after cataract surgery on visual acuity and contrast sensitivity. Hayashi Eye Hospital, Fukuoka, Japan. Thirty-two eyes of 32 consecutive patients who showed marked contraction of the anterior capsule opening after implantation of an intraocular lens were recruited. The area of the anterior capsule opening was measured by Scheimpflug videophotography before and after neodymium:YAG (Nd:YAG) laser anterior capsulotomy and was correlated with visual acuity and contrast sensitivity. After Nd:YAG laser anterior capsulotomy, the mean area of the anterior capsule opening increased significantly from 8.2 mm(2) to 18.0 mm(2) (P<.0001). Contrast sensitivity at most visual angles also improved significantly after Nd:YAG anterior capsulotomy, although visual acuity did not. The area of the anterior capsule opening before anterior capsulotomy was correlated significantly with contrast sensitivity but not with visual acuity, whereas there was no correlation between the opening area after anterior capsulotomy and visual acuity or contrast sensitivity. Contraction of the anterior capsule opening after cataract surgery significantly diminished contrast sensitivity in proportion to the opening area but did not markedly worsen visual acuity. Neodymium:YAG laser anterior capsulotomy improved contrast sensitivity.
Nanocomposite capsules with directional, pulsed nanoparticle release.
Udoh, Christiana E; Cabral, João T; Garbin, Valeria
2017-12-01
The precise spatiotemporal delivery of nanoparticles from polymeric capsules is required for applications ranging from medicine to materials science. These capsules derive key performance aspects from their overall shape and dimensions, porosity, and internal microstructure. To this effect, microfluidics provide an exceptional platform for emulsification and subsequent capsule formation. However, facile and robust approaches for nanocomposite capsule fabrication, exhibiting triggered nanoparticle release, remain elusive because of the complex coupling of polymer-nanoparticle phase behavior, diffusion, phase inversion, and directional solidification. We investigate a model system of polyelectrolyte sodium poly(styrene sulfonate) and 22-nm colloidal silica and demonstrate a robust capsule morphology diagram, achieving a range of internal morphologies, including nucleated and bicontinuous microstructures, as well as isotropic and non-isotropic external shapes. Upon dissolution in water, we find that capsules formed with either neat polymers or neat nanoparticles dissolve rapidly and isotropically, whereas bicontinuous, hierarchical, composite capsules dissolve via directional pulses of nanoparticle clusters without disrupting the scaffold, with time scales tunable from seconds to hours. The versatility, facile assembly, and response of these nanocomposite capsules thus show great promise in precision delivery.
Gandelman, Kuan; Lamson, Michael; Salageanu, Joanne; Bramson, Candace; Matschke, Kyle; Malhotra, Bimal
2015-09-01
ALO-02 is being developed as an abuse-deterrent formulation of extended-release oxycodone hydrochloride with naltrexone hydrochloride sequestered in the core of pellets contained in capsules. The primary objective of this study was to assess the effects of administration of ALO-02 capsule whole under fed conditions or sprinkling the pellets from ALO-02 capsule on applesauce under fasting conditions on the pharmacokinetics (PK) of oxycodone, naltrexone and 6-ß-naltrexol compared with ALO-02 capsule administered whole under fasting conditions. The plasma naltrexone and 6-ß-naltrexol concentrations were used to assess the sequestration of naltrexone in the ALO-02 formulation. The secondary objective was to evaluate the safety and tolerability of single 40 mg doses of ALO-02 in healthy volunteers. This was an IRB-approved, open-label, single-dose, randomized, 3-period crossover study in 24 healthy adult volunteers, aged 18-55 years. Each subject was assigned to receive single 40 mg doses of ALO-02 administered whole (intact capsule) under fasting conditions, administered whole under fed conditions (high-fat breakfast ∼ 950 calories), or sprinkling the contents of the ALO-02 capsule (pellets) over applesauce and swallowing the dose without chewing under fasting conditions. Each treatment was separated by a 7-day washout interval. Plasma samples were analyzed just before dosing through 48 hours postdose for oxycodone, and through 120 hours postdose for naltrexone and its major metabolite, 6-ß-naltrexol. Pharmacokinetic parameters included maximum plasma concentration [Cmax ], area under the plasma concentration-time profile from time 0 to infinity [AUCinf ] and to the last quantifiable concentration [AUClast ], time to Cmax [Tmax ], and terminal half life [t1/2 ]. Adverse events, vital signs, and laboratory parameters were monitored for safety assessment. The t1/2 and Tmax values for oxycodone were similar for all 3 treatments. There was a lack of effect of food (whole capsule, fed vs. fasted) or of sprinkling on applesauce (pellets vs. whole capsule, fasted) on oxycodone bioavailability. The Test/Reference ratios of adjusted geometric means for oxycodone AUCinf , AUClast , and Cmax were 99.2%, 100%, and 107%, respectively, for the effect of food; and 101%, 101%, and 97.5%, respectively, for the effect of sprinkling on applesauce. The 90% confidence intervals contained entirely within the bioequivalence limits of 80% to 125% for each comparison. Naltrexone remained sequestered during each treatment, based on the sporadic and low measurable plasma concentrations of naltrexone and 6-ß-naltrexol. Single doses of ALO-02 40 mg were well tolerated, and adverse events were mild, with no apparent difference in frequency for all 3 treatments. Results indicate that ALO-02 can be administered without regard to food. Also, the contents of ALO-02 can be sprinkled over applesauce and consumed without chewing as an alternative treatment option by subjects with difficulty swallowing. Naltrexone remained sequestered in the ALO-02 formulation under all 3 treatments. © 2015, The American College of Clinical Pharmacology.
NASA Astrophysics Data System (ADS)
Zhang, Xuhui; Xia, Lei; Hao, Shaojun; Chen, Weiliang; Guo, Junyi; Ma, Zhenzhen; Wang, Huamin; Kong, Xuejun; Wang, Hongyu; Zhang, Zhengchen
2018-04-01
To observe the effect of intravenous bone pain Capsule on the ear of mice induced by xylene, swelling of rat models of cervical spondylosis. Weighing 18 ˜ 21g 50 mice, male, were randomly divided into for five groups, which were fed with service for bone pain static capsule suspension, Jingfukang granule suspension 0.5%CMC liquid and the same volume of. Respectively to the mice ear drop of xylene 0.05 ml, 4h after cervical dislocation, the mice were sacrificed and the cut two ear, rapid analytical balance weighing, and calculate the ear swelling degree and the other to take the weight of 200 - 60 250g male SD rats, were randomly divided into for 6 groups, 10 rats in each group, of which 5 groups made cervical spondylosis model. Results: with the blank group than bone pain static capsule group and Jingfukang granule group can significantly reduce mouse auricular dimethylbenzene swelling, significantly reduce ear swelling degree (P < 0.01); the successful establishment of the rat model of cervical spondylosis. With the model group ratio, large, medium and small dose of bone pain static capsule group, Jingfukang granule group (P < 0.01) angle of swash plate of rats increased significantly, the high and middle dose of bone pain static capsule group, Jingfukang granule group can significantly reduce the rat X-ray scores (P < 0.05). Bone pain static capsule can significantly reduce mouse auricular dimethylbenzene swelling. The bone pain capsule has a good effect on the rat model of cervical spondylosis.
Kim, Sena; Ahn, Moonsang; Piao, Yibo; Ha, Yooseok; Choi, Dae-Kyoung; Yi, Min-Hee; Shin, Nara; Kim, Dong Woon; Oh, Sang-Ha
2016-11-01
One of the most serious complications of breast surgery using implants is capsular contracture. Several preventive treatments have been introduced; however, the mechanism of capsule formation has not been resolved completely. The authors previously identified negative effects of botulinum toxin type A on capsule formation, expression of transforming growth factor (TGF)-β1, and differentiation of fibroblasts into myofibroblasts. Thus, the authors investigated how to prevent capsule formation by using botulinum toxin type A, particularly by means of TGF-β1 signaling, in human fibroblasts. In vitro, cultured human fibroblasts were treated with TGF-β1 and/or botulinum toxin type A. Expression of collagen, matrix metalloproteinase, and Smad was examined by Western blotting. The activation of matrix metalloproteinase was observed by gelatin zymography. In vivo, the effect of botulinum toxin type A on the phosphorylation of Smad2 in silicone-induced capsule formation was evaluated by immunocytochemistry. In vitro, the phosphorylation of Smad2 was inhibited by botulinum toxin type A treatment. The expression levels of collagen types 1 and 3 were inhibited by botulinum toxin type A treatment, whereas those of matrix metalloproteinase-2 and matrix metalloproteinase-9 were enhanced. Gelatin zymography experiments confirmed enhanced matrix metalloproteinase-2 activity in collagen degradation. In vivo, botulinum toxin type A treatment reduced capsule thickness and Smad2 phosphorylation in silicone-induced capsules. This study suggests that botulinum toxin type A plays an important role in the inhibition of capsule formation through the TGF-β/Smad signaling pathway. Therapeutic, V.
Protective Effect of Piper aduncum Capsule on DMBA-induced Breast Cancer in Rats.
Arroyo-Acevedo, J; Chávez-Asmat, R J; Anampa-Guzmán, A; Donaires, R; Ráez-Gonzáles, José
2015-01-01
The possible protective effect of Piper aduncum capsule on DMBA (dimethylbenz[α]anthracene)-induced breast cancer in rats was assessed by monitoring the tumor and lung metastases incidence and recording hematological and biochemical parameters and frequency of micronuclei. Mammary carcinogenesis was induced in 36 female Holtzman rats by providing a single subcutaneous injection of DMBA. Oral administration of P. aduncum capsule lowered adenocarcinoma and lymph node metastases incidence. Pulmonary metastasis was significantly lowered (P < 0.05). Hematological indicators showed that the triglyceride level was significantly lowered (P < 0.01) and high-density lipoprotein (HDL) level was significantly increased (P < 0.01). Also, P. aduncum capsule significantly lowered the C reactive protein (CRP) level (P < 0.01) and malondialdehyde level (P < 0.05). There was a significant decrease in the frequency of DMBA-induced micronucleated polychromatic erythrocyte (P < 0.01). Considering the antitumorigenic, hypolipidemic, anti-inflammatory, antioxidant, and antigenotoxic properties of P. aduncum capsule, we conclude that it has a protective effect on DMBA-induced breast cancer in rats.
Protective Effect of Piper aduncum Capsule on DMBA-induced Breast Cancer in Rats
Arroyo-Acevedo, J; Chávez-Asmat, RJ; Anampa-Guzmán, A; Donaires, R; Ráez-Gonzáles, José
2015-01-01
The possible protective effect of Piper aduncum capsule on DMBA (dimethylbenz[α]anthracene)-induced breast cancer in rats was assessed by monitoring the tumor and lung metastases incidence and recording hematological and biochemical parameters and frequency of micronuclei. Mammary carcinogenesis was induced in 36 female Holtzman rats by providing a single subcutaneous injection of DMBA. Oral administration of P. aduncum capsule lowered adenocarcinoma and lymph node metastases incidence. Pulmonary metastasis was significantly lowered (P < 0.05). Hematological indicators showed that the triglyceride level was significantly lowered (P < 0.01) and high-density lipoprotein (HDL) level was significantly increased (P < 0.01). Also, P. aduncum capsule significantly lowered the C reactive protein (CRP) level (P < 0.01) and malondialdehyde level (P < 0.05). There was a significant decrease in the frequency of DMBA-induced micronucleated polychromatic erythrocyte (P < 0.01). Considering the antitumorigenic, hypolipidemic, anti-inflammatory, antioxidant, and antigenotoxic properties of P. aduncum capsule, we conclude that it has a protective effect on DMBA-induced breast cancer in rats. PMID:26157333
Modeling microcapsules that communicate through nanoparticles to undergo self-propelled motion.
Usta, O Berk; Alexeev, Alexander; Zhu, Guangdong; Balazs, Anna C
2008-03-01
Using simulation and theory, we demonstrate how nanoparticles can be harnessed to regulate the interaction between two initially stationary microcapsules on a surface and promote the self-propelled motion of these capsules along the substrate. The first microcapsule, the "signaling" capsule, encases nanoparticles, which diffuse from the interior of this carrier and into the surrounding solution; the second capsule is the "target" capsule, which is initially devoid of particles. Nanoparticles released from the signaling capsule modify the underlying substrate and thereby initiate the motion of the target capsule. The latter motion activates hydrodynamic interactions, which trigger the signaling capsule to follow the target. The continued release of the nanoparticles sustains the motion of both capsules. In effect, the system constitutes a synthetic analogue of biological cell signaling and our findings can shed light on fundamental physical forces that control interactions between cells. Our findings can also yield guidelines for manipulating the interactions of synthetic microcapsules in microfluidic devices.
A locomotion mechanism with external magnetic guidance for active capsule endoscope.
Wang, Xiaona; Meng, Max Q H; Chen, Xijun
2010-01-01
Gastrointestinal (GI) disorder is one of the most common diseases in human body. The swallowable wireless capsule endoscopy has been proved to be a convenient, painless and effective way to examine the whole GI tract. However, lack of motion control makes the movement of the capsule substantially random, resulting in missing diagnosis. In this paper, a locomotion mechanism is developed for the next-generation active capsule endoscope. An internal actuator integrated on-board the capsule is designed to provide driving force and improve the dexterity. A small permanent magnet enclosed inside the capsule interacts with an external magnetic field to control the capsule's orientation and offer extra driving force. This mechanism avoids sophisticated and bulky control system and reduces power consumption inside the capsule. Ex-vivo experimental results showed that it can make a controllable movement inside the porcine large intestine. The mechanism also has the potential to be a platform for further development, such as devices of operations, spraying medicine, biopsy etc.
Electron microscopic examination of the anterior lens capsule in a case of Alport's syndrome.
Citirik, Mehmet; Batman, Cosar; Men, Gamze; Tuncel, Murvet; Zilelioglu, Orhan
2007-09-01
To report a case of Alport's syndrome and to present electronmicroscopic examination findings of the anterior lens capsule of this patient. A 21-year-old man was referred for low visual acuity and retinal pigment epithelial changes in the left eye. The patient and his relatives underwent detailed ophthalmological examination, including electrophysiological testing. The patient also underwent electronmicroscopic examination of the anterior lens capsule. His visual acuity was 6/18 OD and 6/15 OS. Anterior lenticonus and subcapsular opacities were observed in the left eye. Cataract extraction by phacoemulsification with intraocular lens implantation was performed for his poor visual performance. During the capsulorhexis, the remarkably thin and fragile anterior capsule was noted and removed. Ultrastructural analysis of the anterior lens capsule showed a thinner central zone compared with the periphery. The course of Alport's syndrome can be ameliorated by early diagnosis. Therefore, the ophthalmological examination of a patient with anterior lenticonus must be combined with a detailed medical evaluation. Ultrastructural analysis of the lens capsule can support the diagnosis of Alport's syndrome.
High-density carbon capsule experiments on the national ignition facility
Ross, J. S.; Ho, D.; Milovich, J.; ...
2015-02-25
Indirect-drive implosions with a high-density carbon (HDC) capsule were conducted on the National Ignition Facility (NIF) to test HDC properties as an ablator material for inertial confinement fusion. In this study, a series of five experiments were completed with 76-μm-thick HDC capsules using a four-shock laser pulse optimized for HDC. The pulse delivered a total energy of 1.3 MJ with a peak power of 360 TW. The experiment demonstrated good laser to target coupling (~90 %) and excellent nuclear performance. Lastly, a deuterium and tritium gas-filled HDC capsule implosion produced a neutron yield of 1.6×10 15 ± 3×10 13, amore » yield over simulated in one dimension of 70%.« less
How does dietary particle size affect carnivore gastrointestinal transit: A dog model.
De Cuyper, A; Hesta, M; Tibosch, S; Wanke, C; Clauss, M; Janssens, G P J
2018-04-01
The effect of dietary particle size on gastrointestinal transit in carnivores has not been studied and might offer more insight into their digestive physiology. This study evaluated the effect of two dietary particle sizes (fine = 7.8 mm vs. coarse = 13 mm) of chunked day-old chicks on transit parameters in dogs. Six beagle dogs were fed both dietary treatments in a crossover design of 7 days with transit testing on the fifth day. Transit parameters were assessed using two markers, that is a wireless motility capsule (IntelliCap ® ) and titanium oxide (TiO 2 ). Dietary particle size did not affect gastric emptying time (GRT), small bowel transit time (SBTT), colonic transit time (CTT) and total transit time (aTTT) of the capsule (p > .05). There was no effect of dietary particle size on TiO 2 mean retention time (MRT) (p > .05). The time of last TiO 2 excretion (MaxRT) differed (p = .013) between diets, being later for the coarse diet. Both MRT (R = 0.617, p = .032) and MaxRT (R = 0.814; p = .001) were positively correlated to aTTT. The ratio MRT/aTTT tended towards a difference between diets (p = .059) with the coarse diet exceeding fine diet values. Results show that the difference between capsule measurements and TiO 2 is larger for the fine than the coarse diet suggesting that the capsule becomes more accurate when dietary particle size approaches marker size. Dietary particle size might have affected transit parameters but differences are too small to claim major physiological consequences. © 2017 Blackwell Verlag GmbH.
Artist concept of Mercury program study of medical effects and technology
NASA Technical Reports Server (NTRS)
1964-01-01
Artist concept of Mercury program study of medical effects and technology development. Drawing depicts cut-away view of Mercury capsule orbiting the Earth, showing the astronaut and his capsule's hardware.
van den Hout, Wilbert B; Caljouw, Monique A A; Putter, Hein; Cools, Herman J M; Gussekloo, Jacobijn
2014-01-01
Objectives To investigate whether the preventive use of cranberry capsules in long-term care facility (LTCF) residents is cost-effective depending on urinary tract infection (UTI) risk. Design Economic evaluation with a randomized controlled trial. Setting Long-term care facilities. Participants LTCF residents (N = 928, 703 female, median age 84), stratified according to UTI risk. Measurements UTI incidence (clinically or strictly defined), survival, quality of life, quality-adjusted life years (QALYs), and costs. Results In the weeks after a clinical UTI, participants showed a significant but moderate deterioration in quality of life, survival, care dependency, and costs. In high-UTI-risk participants, cranberry costs were estimated at €439 per year (1.00 euro = 1.37 U.S. dollar), which is €3,800 per prevented clinically defined UTI (95% confidence interval = €1,300–infinity). Using the strict UTI definition, the use of cranberry increased costs without preventing UTIs. Taking cranberry capsules had a 22% probability of being cost-effective compared with placebo (at a willingness to pay of €40,000 per QALY). In low-UTI-risk participants, use of cranberry capsules was only 3% likely to be cost-effective. Conclusion In high-UTI-risk residents, taking cranberry capsules may be effective in preventing UTIs but is not likely to be cost-effective in the investigated dosage, frequency, and setting. In low-UTI-risk LTCF residents, taking cranberry capsules twice daily is neither effective nor cost-effective. PMID:25180379
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This volume contains the interim change notice for physical testing. Covered are: properties of solutions, slurries, and sludges; rheological measurement with cone/plate viscometer; % solids determination; particle size distribution by laser scanning; penetration resistance of radioactive waste; operation of differential scanning calorimeter, thermogravimetric analyzer, and high temperature DTA and DSC; sodium rod for sodium bonded fuel; filling SP-100 fuel capsules; sodium filling of BEATRIX-II type capsules; removal of alkali metals with ammonia; specific gravity of highly radioactive solutions; bulk density of radioactive granular solids; purification of Li by hot gettering/filtration; and Li filling of MOTA capsules.
Symptomatic retention of the Agile® patency capsule.
Egea Valenzuela, Juan; Estrella Díez, Esther; Alberca de Las Parras, Fernando
2017-06-01
The Agile® capsule has shown to be useful when evaluating the patency of the small bowel in patients prior to capsule endoscopy studies. It is a safe tool and a low rate of complications have been reported, highlighting symptomatic retention, although references in literature are scarce and it is only observed in 1.2% of the procedures. We present the case of a symptomatic retention of this device in a patient with previously known colonic Crohn's disease in who a small bowel study was indicated and was sent for prior patency test.
Gao, Hui; Goriacheva, Olga A; Tarakina, Nadezda V; Sukhorukov, Gleb B
2016-04-20
Microcapsules that can be efficiently loaded with small molecules and effectively released at the target area through the degradation of the capsule shells hold great potential for treating diseases. Traditional biodegradable polyelectrolyte (PE) capsules can be degraded by cells and eliminated from the body but fail to encapsulate drugs with small molecular weight. Here, we report a poly-l-arginine hydrochloride (PARG)/dextran sulfate sodium salt (DEXS)/silica (SiO2) composite capsule that can be destructed in cells and of which the in situ formed inorganic SiO2 enables loading of small model molecules, Rhodamine B (Rh-B). The composite capsules were fabricated based on the layer-by-layer (LbL) technique and the hydrolysis of tetraethoxysilane (TEOS). Capsules composed of nondegradable PEs and SiO2, polyllamine hydrochloride (PAH)/poly(sodium 4-styrenesulfonate) (PSS)/silica (the control sample), were prepared and briefly compared with the degradable composite capsules. An intracellular degradation study of both types of composite capsules revealed that PARG/DEXS/silica capsules were degraded into fragments and lead to the release of model molecules in a relatively short time (2 h), while the structure of PAH/PSS/silica capsules remained intact even after 3 days incubation with B50 cells. Such results indicated that the polymer components played a significant role in the degradability of the SiO2. Specifically, PAH/PSS scaffolds blocked the degradation of SiO2. For PARG/DEXS/silica capsules, we proposed the effects of both hydrolytic degradation of amorphous silica and enzymatic degradation of PARG/DEXS polymers as a cell degradation mechanism. All the results demonstrated a new type of functional composite microcapsule with low permeability, good biocompatibility, and biodegradability for potential medical applications.
Yao, Hsuan-Ming; Hsu, Ann; Gupta, Suneel; Modi, Nishit B.
2016-01-01
Objectives IPX066 is an oral, extended-release capsule formulation of carbidopa-levodopa (CD-LD) available in 4 strengths. The goals of this investigation were to assess the dose proportionality of IPX066 and to study the effects of a high-fat, high-calorie meal and of sprinkling the capsule contents on applesauce on the pharmacokinetics of IPX066 in healthy volunteers. Methods Three open-label studies were conducted. In the first study, subjects received 1 capsule of each IPX066 strength (23.75–95, 36.25–145, 48.75–195, and 61.25–245 mg of CD-LD). In the second study, subjects received 1 and 2 capsules of IPX066 245-mg LD under fasting conditions. In the third study, subjects received 2 capsules of IPX066 245-mg LD under 3 conditions: fasting; following a high-fat, high-calorie breakfast; and with the capsule contents sprinkled on applesauce under fasting conditions. Results Peak plasma concentrations (Cmax) and systemic exposure (AUCt, AUCinf) for LD and CD increased dose-proportionally over the range of the IPX066 capsule strengths. Comparison of 1 and 2 IPX066 245-mg LD capsules showed dose-proportional pharmacokinetics for Cmax and AUCt. Sprinkling the capsule contents on applesauce did not affect the pharmacokinetics. A high-fat, high-calorie meal delayed the initial increase in LD concentration by approximately 1 to 2 hours, reduced Cmax by 21%, and increased AUCinf by 13% compared with the fasted state. Conclusions IPX066 shows dose-proportional pharmacokinetics. Sprinkling the capsule contents on applesauce does not affect the pharmacokinetics; a high-fat, high-calorie meal delayed absorption by 1 to 2 hours, slightly reduced Cmax, and slightly increased extent of absorption. PMID:26626430
Yao, Hsuan-Ming; Hsu, Ann; Gupta, Suneel; Modi, Nishit B
2016-01-01
IPX066 is an oral, extended-release capsule formulation of carbidopa-levodopa (CD-LD) available in 4 strengths. The goals of this investigation were to assess the dose proportionality of IPX066 and to study the effects of a high-fat, high-calorie meal and of sprinkling the capsule contents on applesauce on the pharmacokinetics of IPX066 in healthy volunteers. Three open-label studies were conducted. In the first study, subjects received 1 capsule of each IPX066 strength (23.75-95, 36.25-145, 48.75-195, and 61.25-245 mg of CD-LD). In the second study, subjects received 1 and 2 capsules of IPX066 245-mg LD under fasting conditions. In the third study, subjects received 2 capsules of IPX066 245-mg LD under 3 conditions: fasting; following a high-fat, high-calorie breakfast; and with the capsule contents sprinkled on applesauce under fasting conditions. Peak plasma concentrations (Cmax) and systemic exposure (AUCt, AUCinf) for LD and CD increased dose-proportionally over the range of the IPX066 capsule strengths. Comparison of 1 and 2 IPX066 245-mg LD capsules showed dose-proportional pharmacokinetics for Cmax and AUCt. Sprinkling the capsule contents on applesauce did not affect the pharmacokinetics. A high-fat, high-calorie meal delayed the initial increase in LD concentration by approximately 1 to 2 hours, reduced Cmax by 21%, and increased AUCinf by 13% compared with the fasted state. IPX066 shows dose-proportional pharmacokinetics. Sprinkling the capsule contents on applesauce does not affect the pharmacokinetics; a high-fat, high-calorie meal delayed absorption by 1 to 2 hours, slightly reduced Cmax, and slightly increased extent of absorption.
Antiobesity effects of Undaria lipid capsules prepared with scallop phospholipids.
Okada, Tomoko; Mizuno, Yasuyuki; Sibayama, Shinichi; Hosokawa, Masashi; Miyashita, Kazuo
2011-01-01
Based on previous research findings, a capsule was developed containing n-3 polyunsaturated fatty acid rich scallop phospholipids (PLs) with an incorporation of brown seaweed (Undaria pinnatifida) lipids (ULs) containing fucoxanthin. The antiobesity effects of the capsules were evaluated with an animal model using 3-wk-old male KK-A(y) mice. Each group received different combinations of lipid (UL, PL, UL + PL, or UL + PL capsule) either incorporated into the diet or into drinking water. Animals were sacrificed after a 4-wk experimental feeding period, and adipose tissues and organs were dissected and weighed. Blood samples were obtained to determine plasma lipid profiles. Uncoupling protein 1 (UCP1) mRNA expression levels were determined by real-time polymerase chain reaction analysis, and UCP1 expression was determined by western blotting analysis. Treatment with either UL alone or UL + PL (capsule) through drinking water resulted in a significant reduction in body weight, compared to the control group. The total white adipose tissue weight of mice fed the UL + PL capsule in drinking water was significantly reduced. Both UCP1 and UCP1 mRNA expression in epididymal fat from mice fed the capsule were significantly higher than in the control group. These results suggest that incorporation of UL into scallop-derived PL by means of capsulation may lead to an additive increase in the antiobesity properties of these bioactive lipids.
[Study on nano-CaCO3 applicated in Xin Yue Shu Capsules preliminarily].
Jiang, Yan-Rong; Zhang, Zhen-Hai; Cui, Li; He, Jun-Jie; Hu, Shao-Ying; Jia, Xiao-Bin
2012-11-01
To investigate the characteristics of nano-CaCO3 applicated in Xin Yue Shu Capsules. Studied the effect of different dosages of aerosil or nano-CaCO3 on fluidity, bulk density, moisture absorption of Xin Yue Shu capsules spray drying powder. In vitro dissolution and ferulic acid stability of Xin Yue Shu capsules was observed. It significantly improved powder fluidity and bulk density of Xin Yue Shu spray drying powder when aerosil or nano-CaCO3 was added. But there was no significant effect on powder moisture absorption, ferulic acid in vitro dissolution and ferulic acid stability. The effect of Nano-CaCO3 on improving powder fluidity and bulk density applicated in the spray drying powder of traditional Chinese medicine deserves studying further.
In situ encapsulation of liquids by means of crystallization
NASA Astrophysics Data System (ADS)
Hartwig, Anne; Ulrich, Joachim
2017-07-01
The in situ encapsulation process is due to its few process steps an innovative and cost effective alternative to common encapsulation techniques. It combines the well-known processes of pastillation and crystallization. This concept is proven with case studies of three xylitol capsules which vary in composition and size. It could be shown that the knowledge concerning the solubility of the components is essential to determine the suitable production conditions. The application of seed crystals and the temperatures during the process have major effects on the capsules quality. A fast crystallization of the capsules results in an instable shell. However, with increasing layer thickness of the shell, the crushing force that needs to be applied to break the capsules is increasing as well. But the stability which is related to the capsules size is decreasing with increasing diameter, even though layer thickness and crushing force are increasing, too.
Rare and Severe Maxillofacial Injury Due to Tear Gas Capsules: Report of Three Cases.
Çorbacɩoğlu, Şeref Kerem; Güler, Sertaç; Er, Erhan; Seviner, Meltem; Aslan, Şahin; Aksel, Gökhan
2016-03-01
Tear gases are used by police or armed forces for control of riots or social events or by the general population for private self-defense. These agents are used widely throughout the world, but some harmful effects have reported. In addition, despite well-defined chemical side effects documented in the literature, data are insufficient regarding mechanical injury due to tear gas capsules. We report three cases of severe maxillofacial injury in patients who had these capsules fired from tear gas guns directly to their faces. The capsules penetrated the patients' faces, causing potentially fatal injuries. To our knowledge, reports of this kind of injury related to tear gas capsules are very rare in the literature. In conclusion, tear gas guns may be very dangerous in terms of human health and they may cause severe injuries, especially when they are not used according to strict guidelines. © 2015 American Academy of Forensic Sciences.
Efficacy of a capsule conjugate vaccine against inhalational anthrax in rabbits and monkeys.
Chabot, Donald J; Joyce, Joseph; Caulfield, Michael; Cook, James; Hepler, Robert; Wang, Su; Vietri, Nicholas J; Ruthel, Gordon; Shoop, Wesley; Pitt, Louise; Leffel, Elizabeth; Ribot, Wilson; Friedlander, Arthur M
2012-01-20
Bacillus anthracis, the causative agent of anthrax, is recognized as one of the most serious bioterrorism threats. The current human vaccines are based on the protective antigen component of the anthrax toxins. Concern about possible vaccine resistant strains and reliance on a single antigen has prompted the search for additional immunogens. Bacterial capsules, as surface-expressed virulence factors, are well-established components of several licensed vaccines. In a previous study we showed that an anthrax vaccine consisting of the B. anthracis poly-γ-D-glutamic acid capsule covalently conjugated to the outer membrane protein complex of Neisseria meningitidis serotype B protected mice against parenteral B. anthracis challenge. Here we tested this vaccine in rabbits and monkeys against an aerosol spore challenge. The vaccine induced anti-capsule antibody responses in both species, measured by ELISA and a macrophage opsono-adherence assay. While rabbits were not protected against a high aerosol challenge dose, significant protection was observed in monkeys receiving the capsule conjugate vaccine. The results confirm that the capsule is a protective immunogen against anthrax, being the first non-toxin antigen shown to be efficacious in monkeys and suggest that addition of capsule may broaden and enhance the protection afforded by protective antigen-based vaccines. Published by Elsevier Ltd.
Simulating Space Capsule Water Landing with Explicit Finite Element Method
NASA Technical Reports Server (NTRS)
Wang, John T.; Lyle, Karen H.
2007-01-01
A study of using an explicit nonlinear dynamic finite element code for simulating the water landing of a space capsule was performed. The finite element model contains Lagrangian shell elements for the space capsule and Eulerian solid elements for the water and air. An Arbitrary Lagrangian Eulerian (ALE) solver and a penalty coupling method were used for predicting the fluid and structure interaction forces. The space capsule was first assumed to be rigid, so the numerical results could be correlated with closed form solutions. The water and air meshes were continuously refined until the solution was converged. The converged maximum deceleration predicted is bounded by the classical von Karman and Wagner solutions and is considered to be an adequate solution. The refined water and air meshes were then used in the models for simulating the water landing of a capsule model that has a flexible bottom. For small pitch angle cases, the maximum deceleration from the flexible capsule model was found to be significantly greater than the maximum deceleration obtained from the corresponding rigid model. For large pitch angle cases, the difference between the maximum deceleration of the flexible model and that of its corresponding rigid model is smaller. Test data of Apollo space capsules with a flexible heat shield qualitatively support the findings presented in this paper.
NASA Astrophysics Data System (ADS)
Muhardina, V.; Ermaya, D.; Aisyah, Y.; Haryani, S.
2018-02-01
Probiotic capsule is an innovation in functional food sector. It is used to preserve the living cells of probiotic bacteria during processing and storage. In this research, the improvement of probiotic viability is studied by using two kinds of encapsulating biomaterials and different concentration of tofu waste flour. Extrusion is selected method for encapsulation process. The purpose of this study is to examine the quality of probiotic capsule by evaluating the lactic acid bacteria performance and its physical characteristic. The article provides the data of probiotic bacteria activity related to their living cells present in capsule, activity in fermentation media compare to uncapsulated bacteria, and panelists’ preferences of capsule’s physical properties. The data is analyzed statistically by using ANOVA. The result shows that variables in this study affect the number of bacteria, their metabolic activity in producing acid during fermentation, and physical appearance of the capsule. Combination of alginate and tofu waste flour allows the multiplication of bacteria to a high number, and forms elastic, yellow and cloudy capsule, while with carrageenan, it causes the growth of a few numbers of bacteria which affects to a moderate pH and produces elastic, creamy and transparent capsule.
Multiple internalization pathways of polyelectrolyte multilayer capsules into mammalian cells.
Kastl, Lena; Sasse, Daniel; Wulf, Verena; Hartmann, Raimo; Mircheski, Josif; Ranke, Christiane; Carregal-Romero, Susana; Martínez-López, José Antonio; Fernández-Chacón, Rafael; Parak, Wolfgang J; Elsasser, Hans-Peter; Rivera Gil, Pilar
2013-08-27
Polyelectrolyte multilayer (PEM) capsules are carrier vehicles with great potential for biomedical applications. With the future aim of designing biocompatible, effective therapeutic delivery systems (e.g., for cancer), the pathway of internalization (uptake and fate) of PEM capsules was investigated. In particular the following experiments were performed: (i) the study of capsule co-localization with established endocytic markers, (ii) switching-off endocytotic pathways with pharmaceutical/chemical inhibitors, and (iii) characterization and quantification of capsule uptake with confocal and electron microscopy. As result, capsules co-localized with lipid rafts and with phagolysosomes, but not with other endocytic vesicles. Chemical interference of endocytosis with chemical blockers indicated that PEM capsules enter the investigated cell lines through a mechanism slightly sensitive to electrostatic interactions, independent of clathrin and caveolae, and strongly dependent on cholesterol-rich domains and organelle acidification. Microscopic characterization of cells during capsule uptake showed the formation of phagocytic cups (vesicles) to engulf the capsules, an increased number of mitochondria, and a final localization in the perinuclear cytoplasma. Combining all these indicators we conclude that PEM capsule internalization in general occurs as a combination of different sequential mechanisms. Initially, an adsorptive mechanism due to strong electrostatic interactions governs the stabilization of the capsules at the cell surface. Membrane ruffling and filopodia extensions are responsible for capsule engulfing through the formation of a phagocytic cup. Co-localization with lipid raft domains activates the cell to initiate a lipid-raft-mediated macropinocytosis. Internalization vesicles are very acidic and co-localize only with phagolysosome markers, excluding caveolin-mediated pathways and indicating that upon phagocytosis the capsules are sorted to heterophagolysosomes.
Sundaramurthy, Anandhakumar; Sundramoorthy, Ashok K
2018-02-01
In recent years, the design of stimuli-responsive hollow polymeric capsules is of tremendous interest for the scientific community because of the broad application of these capsules in the biomedical field. The use of weak polyelectrolytes as layer components for capsule fabrication is especially interesting as it results in hollow capsules that show unique release characteristics under physiological conditions. In this work, a methodology to prepare sub-micron sized alginate doped calcium carbonate (CaCO 3 ) particles through controlled precipitation in the presence of alginate is reported. Hollow capsules obtained by Layer-by-Layer (LbL) assembly of poly(allylamine hydrochloride) (PAH) and poly(methacrylic acid) (PMA) are showing an interconnected alginate matrix in the interior of the capsules. Investigations showed that the presence of alginate matrix enhances the encapsulation of cationic molecules (e.g. doxorubicin hydrochloride) manifold by charge controlled attraction mechanism. Capsule permeability investigated by confocal laser scanning microscopy revealed that the transformation from an open state to closed state is accompanied by an intermediate state where capsules are neither open nor closed. Furthermore, time dependent study indicated that the encapsulation process is linear as a function of time. The cell viability experiments demonstrated excellent biocompatibility of hollow capsules with mouse embryonic fibroblast cells. Anticancer investigations showed that DOX loaded capsules have significant anti-proliferative characteristics against HeLa cells. Such capsules have high potential for use as drug carrier for cationic drugs in cancer therapy. Copyright © 2017 Elsevier B.V. All rights reserved.
Space capsule mounted in the Full Scale Wind Tunnel
1959-01-22
The Mercury space capsule undergoing tests in Full Scale Wind Tunnel, January 1959. Photograph published in Winds of Change, 75th Anniversary NASA publication, page 75, by James Schultz. Also Photograph published in Engineer in Charge: A History of the Langley Aeronautical Laboratory, 1917-1958, page 389, by James R. Hansen.
Release of Boilerplate Mercury Capsule Sequence
1958-12-16
Photographed on: 12 16 58. -- L58-1083a caption: Sequenced pictures showing events from release of boilerplate Mercury capsule from C-130 airplane to opening of recovery parachute, December 1958. Photograph published in A New Dimension Wallops Island Flight Test Range: The First Fifteen Years by Joseph Shortal. A NASA publication, page 644.
Sienkiewicz, Waldemar; Dudek, Agnieszka; Czaja, Krzysztof; Janeczek, Maciej; Chrószcz, Aleksander; Kaleczyc, Jerzy
2018-01-01
Objective To evaluate efficacy of denervation of the of the hip joint capsule (HJC), as a treatment of hip joint pain. Specifically, we tested the hypothesis that HJC denervation will significantly reduce the number of sensory neurons innervating the capsule. Study design Denervation of the HJC from a medial or lateral approach was followed by retrograde tracing of sensory neurons innervating the capsule. Animals Twenty adult male sheep (30–40 kg of body weight; Polish merino breed) were used in the study. Methods The hip joint was denervated from medial (n = 5) or lateral (n = 5) surgical approaches. Immediately after denervation, the retrograde neural tract tracer Fast Blue (FB) was injected into the HJC. An additional ten animals (n = 5 for medial and n = 5 for lateral approach) received the same treatment without HJC denervation to provide the appropriate controls. Results Results of the study revealed that the vast majority of retrogradely labelled sensory neurons innervating the HJC originate from fifth lumbar to second sacral dorsal root ganglia. Both the medial and the lateral denervations significantly reduced the number of sensory neurons innervating the HJC (39.2% and 69.0% reduction respectively). Conclusions These results show that denervation of the HJC is an effective surgical procedure for reduction of the sensory neuronal input to the HJC. Moreover, the lateral approach was found to be significantly more effective for reducing sensory innervation as compared to the medial one. PMID:29329303
Su, Andrew; Gandhy, Rita; Barlow, Carrolee; Triadafilopoulos, George
2016-01-01
Background The aetiology of constipation in Parkinson's disease remains poorly understood. Defaecatory dyssynergia, anal sphincter spasticity and slow transit constipation may, individually or collectively, play a role. Aims In this retrospective cohort analysis of patients with Parkinson's disease and chronic constipation, we determined the utility of high-resolution anorectal manometry, balloon expulsion and wireless motility capsule testing in defining the underlying aetiology for constipation. Methods In this retrospective cohort study, consecutive patients with Parkinson's disease and chronic constipation underwent clinical assessment, manometry with balloon expulsion and wireless motility capsule testing using standard protocols. Results We studied 66 patients fulfilling Rome IV criteria for functional constipation. Most patients (89%) had abnormal manometry, exhibiting various types of defaecatory dyssynergia (mostly types II and IV), abnormal balloon expulsion, diminished rectal sensation and, in some, lacking rectoanal inhibitory reflex. 62% exhibited colonic transit delay by wireless motility capsule study, while 57% had combined manometric and transit abnormalities, suggesting of overlap constipation. Symptoms of infrequent defaecation, straining and incomplete evacuation were not discriminatory. There was a relationship between constipation scores and colonic transit times (p=0.01); Parkinson's disease scores and duration were not correlated with either the manometric or transit findings. Faecal incontinence was seen in 26% of the patients. Conclusions Chronic constipation in patients with Parkinson's disease may reflect pelvic floor dyssynergia, slow transit constipation or both, and may be associated with faecal incontinence, suggesting both motor and autonomic dysfunction. Anorectal manometry and wireless motility capsule testing are useful in the assessment of these patients. PMID:27843572
Effect of bending on the dynamics and wrinkle formation for a capsule in shear flow
NASA Astrophysics Data System (ADS)
Salsac, Anne-Virginie; Dupont, Claire; Barthes-Biesel, Dominique; Vidrascu, Marina; Le Tallec, Patrick
2014-11-01
When microcapsules are subjected to an external flow, the droplets enclosed within a thin hyperelastic wall undergo large deformations, which often lead to buckling of the thin capsule wall. The objective is to study numerically an initially spherical capsule in shear flow and analyze the influence of the membrane bending rigidity on the capsule dynamics and wrinkle formation. The 3D fluid-structure interactions are modeled coupling a boundary integral method to solve for the internal and external Stokes flows with a thin shell finite element method to solve for the wall deformation. Hyperelastic constitutive laws are implemented to model the deformation of the capsule mid-surface and the generalized Hooke's law for the bending effects. We show that the capsule global motion and deformation are mainly governed by in-plane membrane tensions and are marginally influenced by the bending stiffness Ks. The bending stiffness, however, plays a role locally in regions of compressive tensions. The wrinkle wavelength depends on Ks following a power law, which provides an experimental technique to determine the value of Ks through inverse analysis.
Liu, Gang; Yan, Guozheng; Zhu, Bingquan; Lu, Li
2016-11-01
In recent years, wireless capsule endoscopy (WCE) has been a state-of-the-art tool to examine disorders of the human gastrointestinal tract painlessly. However, system miniaturization, enhancement of the image-data transfer rate and power consumption reduction for the capsule are still key challenges. In this paper, a video capsule endoscopy system with a low-power controlling and processing application-specific integrated circuit (ASIC) is designed and fabricated. In the design, these challenges are resolved by employing a microimage sensor, a novel radio frequency transmitter with an on-off keying modulation rate of 20 Mbps, and an ASIC structure that includes a clock management module, a power-efficient image compression module and a power management unit. An ASIC-based prototype capsule, which measures Φ11 mm × 25 mm, has been developed here. Test results show that the designed ASIC consumes much less power than most of the other WCE systems and that its total power consumption per frame is the least. The image compression module can realize high near-lossless compression rate (3.69) and high image quality (46.2 dB). The proposed system supports multi-spectral imaging, including white light imaging and autofluorescence imaging, at a maximum frame rate of 24 fps and with a resolution of 400 × 400. Tests and in vivo trials in pigs have proved the feasibility of the entire system, but further improvements in capsule control and compression performance inside the ASIC are needed in the future.
Li, Dongmei; Zheng, Ji; Wang, Mingyang; Feng, Lu; Liu, Yanyong; Yang, Nan; Zuo, Pingping
2016-06-20
Wuling powder (trade name: Wuling capsule), a traditional Chinese medicine (TCM), was extracted from mycelia of precious Xylaria Nigripes (Kl.) Sacc by modern fermentation technology, and has been claimed to be fully potent in improving the signs of insomnia and cognitive deficits. Moreover, Wuling capsule was effective in treating post-stroke and orther co-cormbid depression both in clinical and in basic research. In order to clarify the molecular mechanisms of the antidepressant effect of Wuling powder, we established learned helplessness (LH) depression animal model and focused on 18kDa translocator protein (TSPO) mediated-mitophagy pathway. Mice were exposed to the inescapable e-shock (IS) once a day for three consecutive days to establish the LH model. Then mice were orally administered Wuling powder for 2 weeks. For the behavioral assessment, Shuttle box test, novelty suppressed feeding test (NSF) and forced swimming test (FST) were performed. Following the behavioral assessment, we assessed the protein expression level that were related to TSPO-mediated mitophagy signaling pathway by Western blotting analysis. Finally, immunohistochemistry method was used to assess the neuroprotective effects of Wuling powder. Compared with mice that were subjected to inescapable e-shock, Wuling powder exhibited antidepressant effect in the multiple behavioral tests. In addition, Wuling powder altered the expression level of multiple proteins related to TSPO-mediated mitophagy signaling pathway. Our results suggested that Wuling powder exhibited an obvious antidepressant effect, which could be due to the improvement of TSPO-mediated mitophagy signaling pathway. Copyright © 2016. Published by Elsevier Ireland Ltd.
A Nonequilibrium Finite-Rate Carbon Ablation Model for Radiating Earth Re-entry Flows
2015-09-17
model was a short half-cylinder made of isomolded graphite and was tested in 8.6 km/ s Earth entry ow. The model surface was heated within a temperature...capsule [98, 49, 112]. For the Star- dust return capsule that had an Earth entry velocity of 12 km/ s , equilibrium surface recession was over predicted...was tested at 8.6 km/ s Earth entry ow monitored by ultraviolet (UV) spec- trometry. The experiments pre-heated the model to high temperatures to
SHERPA Electromechanical Test Bed
NASA Technical Reports Server (NTRS)
Wason, John D.
2005-01-01
SHERPA (Strap-on High-altitude Entry Reconnaissance and Precision Aeromaneuver system) is a concept for low-cost-high-accuracy Martian reentry guidance for small scout-class missions with a capsule diameter of approximately 1 meter. This system uses moving masses to change the center of gravity of the capsule in order to control the lift generated by the controlled imbalance. This project involved designing a small proof-of-concept demonstration system that can be used to test the concept through bench-top testing, hardware-in-the-loop testing, and eventually through a drop test from a helicopter. This project has focused on the Mechatronic design aspects of the system including the mechanical, electrical, computer, and low-level control of the concept demonstration system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Strozzi, David J.; Perkins, L. J.; Marinak, M. M.
The effects of an imposed, axial magnetic fieldmore » $$B_{z0}$$ on hydrodynamics and energetic electrons in inertial confinement fusion indirect-drive hohlraums are studied. We present simulations from the radiation-hydrodynamics code HYDRA of a low-adiabat ignition design for the National Ignition Facility, with and without $$B_{z0}=70~\\text{T}$$. The field’s main hydrodynamic effect is to significantly reduce electron thermal conduction perpendicular to the field. This results in hotter and less dense plasma on the equator between the capsule and hohlraum wall. The inner laser beams experience less inverse bremsstrahlung absorption before reaching the wall. The X-ray drive is thus stronger from the equator with the imposed field. We study superthermal, or ‘hot’, electron dynamics with the particle-in-cell code ZUMA, using plasma conditions from HYDRA. During the early-time laser picket, hot electrons based on two-plasmon decay in the laser entrance hole (Regan et al., Phys. Plasmas, vol. 17(2), 2010, 020703) are guided to the capsule by a 70 T field. Twelve times more energy deposits in the deuterium–tritium fuel. For plasma conditions early in peak laser power, we present mono-energetic test-case studies with ZUMA as well as sources based on inner-beam stimulated Raman scattering. Furthermore, the effect of the field on deuterium–tritium deposition depends strongly on the source location, namely whether hot electrons are generated on field lines that connect to the capsule.« less
[Application of microwave technology in extraction process of Guizhi Fuling capsule].
Wang, Zheng-kuan; Zhou, Mao; Liu, Yuan; Bi, Yu-an; Wang, Zhen-zhong; Xiao, Wei
2015-06-01
In this paper, optimization of the conditions of microwave technique in extraction process of Guizhi Fuling capsule in the condition of a pilot scale was carried out. First of all, through the single factor experiment investigation of various factors, the overall impact tendency and range of each factor were determined. Secondly, L9 (3(4)) orthogonal test optimization was used, and the contents of gallic acid in liquid, paeoniflorin, benzoic acid, cinnamic acid, benzoyl paeoniflorin, amygdalin of the liquid medicine were detected. The extraction rate and comprehensive evaluation were calculated with the extraction effect, as the judgment basis. Theoptimum extraction process of Guizhi Fuling capsule by microwave technology was as follows: the ratio of liquid to solid was 6: 1 added to drinking water, the microwave power was 6 kW, extraction time was 20 min for 3 times. The process of the three batch of amplification through verification, the results are stable, and compared with conventional water extraction has the advantages of energy saving, time saving, high efficiency advantages. The above results show the optimum extracting technology of high efficiency, stable and feasible.
Zhao, Yuanyang; Pan, Yongquan; Yang, Yifan; Batey, Robert; Wang, Jianwei; Li, Yuhao
2015-06-02
Jiangzhi Capsule is an Australian listed patented traditional Chinese medicine and has been used for management of lipid abnormalities over the past 10 years. To obtain a better understanding regarding Jiangzhi Capsule, the present study investigated the effects and underlying mechanisms of Jiangzhi Capsule on chronic fructose overconsumption-induced lipid abnormalities. Male rats were treated with liquid fructose in their drinking water over 14 weeks. Jiangzhi Capsule was co-administered (once daily, by oral gavage) during the last 7 weeks. Indexes of lipid and glucose homeostasis were determined enzymatically, by ELISA and/or histologically. Gene expression was analyzed by real-time PCR, Western blot and/or immunohistochemistry. Treatment with Jiangzhi Capsule (100 mg/kg) attenuated fructose-induced excessive triglyceride accumulation and Oil Red O-stained area in the liver. This effect was accompanied by amelioration of hyperinsulinemia. There was no significant difference in intakes of fructose and chow, and body weight between fructose control and fructose Jiangzhi Capsule-treated groups. Mechanistically, Jiangzhi Capsule downregulated fructose-stimulated hepatic overexpression of sterol regulatory element binding protein (SREBP)-1/1c at the mRNA and protein levels. Accordingly, the SREBP-1c downstream genes, acetyl-CoA carboxylase-1 and stearoyl-CoA desaturase-1, were also inhibited. In addition, acyl-coenzyme A:diacylglycerol acyltransferase (DGAT)-2 expression at the mRNA and protein levels in the liver was also inhibited after Jiangzhi Capsule treatment. In contrast, Jiangzhi Capsule affected neither carbohydrate response element binding protein, peroxisome proliferator-activated receptor (PPAR)-gamma and DGAT-1, nor PPAR-alpha and its target genes. These findings demonstrate the anti-steatotic action of Jiangzhi Capsule in fructose-fed rats, and modulation of hepatic SREBP-1c and DGAT-2 involved in hepatic de novo synthesis of fatty acids and triglyceride, respectively. Our findings provide an evidence-based and mechanistic understanding of Jiangzhi Capsule supporting its application for the prevention and/or treatment of fatty liver and its associated disorders in clinical practice.
Torrado, G; García-Arieta, A; de los Ríos, F; Menéndez, J C; Torrado, S
1999-03-01
Fourier transform infrared (FTIR) spectroscopy and antifoaming activity test have been employed for the quantitative analysis of dimethicone. Linearity, accuracy and precision are presented for both methods. These methods have been also used to compare different dimethicone-containing proprietary medicines. FTIR spectroscopy has shown to be adequate for quantitation of dimethicone in commercial tablets and capsules in order to comply with USP requirements. The antifoaming activity test is able to detect incompatibilities between dimethicone and other constituents. The presence of certain enzymes in some medicinal products increases the defoaming properties of these formulations.
Effects of glucosamine on proteoglycan loss by tendon, ligament and joint capsule explant cultures.
Ilic, M Z; Martinac, B; Samiric, T; Handley, C J
2008-12-01
To investigate the effect of glucosamine on the loss of newly synthesized radiolabeled large and small proteoglycans by bovine tendon, ligament and joint capsule. The kinetics of loss of (35)S-labeled large and small proteoglycans from explant cultures of tendon, ligament and joint capsule treated with 10mM glucosamine was investigated over a 10-day culture period. The kinetics of loss of (35)S-labeled small proteoglycans and the formation of free [(35)S]sulfate were determined for the last 10 days of a 15-day culture period. The proteoglycan core proteins were analyzed by gel electrophoresis followed by fluorography. The metabolism of tendon, ligament and joint capsule explants exposed to 10mM glucosamine was evaluated by incorporation of [(3)H]serine and [(35)S]sulfate into protein and glycosaminoglycans, respectively. Glucosamine at 10mM stimulated the loss of small proteoglycans from ligament explant cultures. This was due to the increased loss of both macromolecular and free [(35)S]sulfate to the medium indicating that glucosamine affected the release of small proteoglycans as well as their intracellular degradation. The degradation pattern of small proteoglycans in ligament was not affected by glucosamine. In contrast, glucosamine did not have an effect on the loss of large or small proteoglycans from tendon and joint capsule or large proteoglycans from ligament explant cultures. The metabolism of cells in tendon, ligament and joint capsule was not impaired by the presence of 10mM glucosamine. Glucosamine stimulated the loss of small proteoglycans from ligament but did not have an effect on small proteoglycan catabolism in joint capsule and tendon or large proteoglycan catabolism in ligament, tendon or synovial capsule. The consequences of glucosamine therapy at clinically relevant concentrations on proteoglycan catabolism in joint fibrous connective tissues need to be further assessed in an animal model.
Navekar, Roya; Rafraf, Maryam; Ghaffari, Aida; Asghari-Jafarabadi, Mohammad; Khoshbaten, Manouchehr
2017-01-01
Insulin and leptin resistance are important risk factors for non-alcoholic fatty liver disease (NAFLD). There is limited evidence regarding the effects of turmeric on NAFLD. The aim of this study was to investigate the effects of turmeric supplementation on glycemic status and serum leptin levels in patients with NAFLD. This double-blind randomized controlled clinical trial was conducted on 46 patients with NAFLD (21males and 25 females) aged 20-60 years old and body mass index (BMI) between 24.9 and 40 kg/m2. The turmeric group (n = 23) was given six turmeric capsules daily for 12 weeks. Each capsule contained 500 mg turmeric powder (6×500 mg). The placebo group (n = 23) was given six placebo capsules daily for the same period. Fasting blood samples, anthropometric measurements, and physical activity levels were collected at the baseline and at the end of the study. Daily dietary intakes also were obtained throughout the study. Data were analyzed by independent t test, paired t test and analysis of covariance. Turmeric consumption decreased serum levels of glucose, insulin, HOMA-IR and leptin (by 1.22, 17.69, 19.48 and 21.33% respectively, p < 0.05 for all) over 12 weeks compared with those variables in the placebo group. Changes in weight, BMI and liver enzymes were not significant compared to the placebo group. Turmeric supplementation improved glucose indexes and serum leptin levels and may be useful in the control of NAFLD complications.
Dimitrakopoulos, P; Kuriakose, S
2015-04-14
Determination of the elastic properties of the membrane of artificial capsules is essential for the better design of the various devices that are utilized in their engineering and biomedical applications. However this task is complicated owing to the combined effects of the shear and area-dilatation moduli on the capsule deformation. Based on computational investigation, we propose a new methodology to determine a membrane's shear modulus, independent of its area-dilatation modulus, by flowing strain-hardening capsules in a converging micro-capillary of comparable size under Stokes flow conditions, and comparing the experimental measurements of the capsule elongation overshooting with computational data. The capsule prestress, if any, can also be determined with the same methodology. The elongation overshooting is practically independent of the viscosity ratio for low and moderate viscosity ratios, and thus a wide range of capsule fluids can be employed. Our proposed experimental device can be readily produced via glass fabrication while owing to the continuous flow in the micro-capillary, the characterization of a large number of artificial capsules is possible.
Malakar, Jadupati; Datta, Prabir Kumar; Purakayastha, Saikat Das; Dey, Sanjay; Nayak, Amit Kumar
2014-03-01
The present study deals with the development and evaluations of stomach-specific floating capsules containing salbutamol sulfate-loaded oil-entrapped alginate-based beads. Salbutamol sulfate-loaded oil-entrapped beads were prepared and capsulated within hard gelatin capsules (size 1). The effects of HPMC K4M and potato starch weight masses on drug encapsulation efficiency (DEE) of beads and cumulative drug release at 10h (R10 h) from capsules was analyzed by 3(2) factorial design. The optimization results indicate increasing of DEE in the oil-entrapped beads and decreasing R10 h from capsules with increment of HPMC K4M and potato starch weight masses. The optimized formulation showed DEE of 70.02 ± 3.16% and R10 h of 56.96 ± 2.92%. These capsules showed floatation over 6h and sustained drug release over 10h in gastric pH (1.2). In vivo X-ray imaging study of optimized floating capsules in rabbits showed stomach-specific gastroretention over a prolonged period. Copyright © 2013 Elsevier B.V. All rights reserved.
Chen, Xiu-Min; Wu, Jia-Qi; Huang, Qing-Chun; Zhang, Jian-Yong; Pen, Jian-Hong; Huang, Zhi-Sheng; Chu, Yong-Liang; He, Xiao-Hong; Wang, Mao-Jie; Huang, Run-Yue
2018-06-01
Biqi capsule is a Traditional Chinese Medicine preparation for treating rheumatoid arthritis (RA), and clinical studies have indicatedthat its effect may be more beneficial than that of Western medicine. The present study aimed to estimate the efficacy and safety of Biqi capsule alone or combined with methotrexate (MTX) compared with MTX alone for treating RA by performing a meta-analysis of randomized controlled trials and controlled clinical trials. A systematic literature search of studies published until March 2017 was performed. References from relevant studies were screened to obtain additional articles. The results were independently evaluated for relevance, and full-text studies were assessed for eligibility. The risk of bias was assessed using the Cochrane collaboration tool for assessing risk of bias. Out of 558 citations that were initially retrieved, a total of 5 studies comprising 522 patients met the inclusion criteria. The risk of bias of these trials was generally unclear or high. Meta-analysis indicated that Biqi capsule had better effects on C-reactive protein [standardized mean difference (SMD), -7.05; 95% CI -(10.77-3.33)] and tender joint count [SMD, -3.02; 95% CI, -(3.81-2.22)] and fewer adverse effects (AEs) than MTX [relative risk (RR), 0.19; 95% CI, 0.08-0.43]. Biqi capsule plus MTX was superior to MTX in terms of the total effect (RR, 1.17; 95% CI, 1.06-1.28), rheumatoid factor [SMD, -12.54; 95% CI, -(16.87-8.20)], swollen joint count [SMD, -1.50; 95% CI, -(1.99-1.01)], score of joint swelling [SMD -2.07; 95% CI, -(2.76-1.38)], tender joint count [SMD, -2.16; 95% CI, -(2.86-1.47)] and score of joint tenderness [SMD, -4.69; 95% CI, -(5.92-3.47)]. There was no difference in AEs between Biqi capsule plus MTX and MTX (RR, 0.71; 95% CI, 0.34-1.50). In conclusion, the present study indicated that compared with MTX, Biqi capsule plus MTX appeared to have more benefits but that Biqi capsule alone was not better for RA patients than MTX. In the other words, Biqi capsule plus MTX is more effective and has fewer AEs compared to MTX. However, the trials selected in the present meta-analysis have various limitations, including the lack of blinding and the short duration of the treatment; therefore, the conclusions are not sufficiently definitive. More randomized controlled trials are necessary to evaluate the use of Biqi capsule for managing RA.
Wu, Xi-li; Sun, Wan-sen; Zhang, Wang-gang; Qiao, Cheng-lin; Wang, Zhu; Wang, Juan
2007-11-01
To explore the effect of Yishen capsule on the serum vascular endothelial growth factor (VEGF), the cell immunity and the theraphic. Serum VEGF and T cell subsets were studied in 30 normal subjects and 83 patients before and after treatment. Compare with normal subjects, CD3, CD4, CD4/CD8 were decreased, CD8 and serum VEGF were increased obviously (P <0. 05 or P <0. 01). After three months treatment with YiShen capsule, CD4/CD8 was increased, CD8 and serum VEGF were decreased significantly (P <0.05 or P <0.01). Yishen capsule can reduce the proteinuria, increase the function of immunity and improve the clinical symptom of patients with chronic glomerulonephritis, achieved the effects of allevating chronic glomerular sclerosis ultimately.
Keshavarz, Seyed Ali; Mostafavi, Seyed-Ali; Akhondzadeh, Shahin; Mohammadi, Mohammad Reza; Hosseini, Saeed; Eshraghian, Mohammad Reza; Chamari, Maryam
2018-06-01
We aimed to evaluate the effects of the omega-3 supplementation on body weight and depression among women with co-morbidity of depression and obesity seeking weight reduction compared with the placebo. Sixty five patients with co-morbidity of depression and overweight/obesity (BMI ≥ 25) signed the informed consent form and enrolled into this 12-week double-blind, placebo-controlled randomized clinical Trial. Subsequently, participants randomly assigned into one of the two groups receiving daily 6 capsules of omega-3 (each capsule containing 180 mg EPA, and 120 mg DHA) or 6 capsules of placebo (two with each meal). We performed body composition assessments and Beck depression inventory at the baseline, and weeks 2, 4, 8, and 12 after the start of the study. One month after stopping the capsules at the follow-up visit, weight was measured to compare weight relapse between the two groups. Forty five patients finished the study. No significant differences were seen between groups regarding demographic and clinical variables at baseline. Using repeated measures ANOVA, omega-3 significantly reduced depression compared with the placebo (P = 0.05). Mean ± SD weight reduction in omega-3 group 3.07 ± 3.4 kg and in the placebo group was 1.16 ± 2.7 kg and the difference between groups was significant using independent sample t-test (p = 0.049). Patients in the omega-3 group did not show significantly more side effects compared to the placebo but they were not successful in preventing weight regain one month after the end of the study. Based on our findings omega-3 capsule as a safe over-the-counter supplement might be helpful in reducing the signs of depression and also body weight in patients with co-morbidity of depression and obesity. Copyright © 2018 European Society for Clinical Nutrition and Metabolism. Published by Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Thoms, K. R.
1975-01-01
Fuel irradiation experiments were designed, built, and operated to test uranium mononitride (UN) fuel clad in tungsten-lined T-111 and uranium dioxide fuel clad in both tungsten-lined T-111 and tungsten-lined Nb-1% Zr. A total of nine fuel pins was irradiated at average cladding temperatures ranging from 931 to 1015 C. The UN experiments, capsules UN-4 and -5, operated for 10,480 and 10,037 hr, respectively, at an average linear heat generation rate of 10 kW/ft. The UO2 experiment, capsule UN-6, operated for 8333 hr at an average linear heat generation rate of approximately 5 kW/ft. Following irradiation, the nine fuel pins were removed from their capsules, externally examined, and sent to the NASA Plum Brook Facility for more detailed postirradiation examination. During visual examination, it was discovered that the cladding of the fuel pin containing dense UN in each of capsules UN-4 and -5 had failed, exposing the UN fuel to the NaK in which the pins were submerged and permitting the release of fission gas from the failed pins. A rough analysis of the fission gas seen in samples of the gas in the fuel pin region indicated fission gas release-to-birth rates from these fuel pins in the range of .00001.
What the Research Tells Us: Class Size Reduction. Information Capsule. Volume 1001
ERIC Educational Resources Information Center
Romanik, Dale
2010-01-01
This Information Capsule examines the background and history in addition to research findings pertaining to class size reduction (CSR). This Capsule concludes that although educational researchers have not definitively agreed upon the effectiveness of CSR, given its almost universal public appeal, there is little doubt it is here to stay in some…
Sanaati, Fateme; Najafi, Safa; Kashaninia, Zahra; Sadeghi, Masoud
2016-01-01
Chemotherapy-induced nausea and vomiting (CINV) places a significant burden on the patient. Herbal agents are the most commonly complementary therapies used among the public. This study was done to determine the effect of ginger and chamomile capsules on nausea and vomiting in cases undergoing chemotherapy for breast cancer (BC). In a randomized, double-blind and clinical trial study, 65 women with BC undergoing chemotherapy were referred to Breast Cancer Research Center, Tehran, Iran, between May 2013 to June 2014. Regimen for ginger group for 5 days before and 5 days after chemotherapy was: 2 times a day and 500 mg capsules of powdered ginger root in addition to a routine antiemetic regimen consisting of dexamethasone, metoclopramide and aprepitant (DMA) capsules. Chamomile group similarly was: 2 times a day and 500 mg capsules of Matricaria chamomilla extract in addition to a routine antiemetic regimen consisting of DMA capsules. Control group, routine antiemetic regimen consisting of DMA capsules. There were no significant differences between the ginger, chamomile and control groups regarding age. Drugs used for chemotherapy were identical and duration of disease was also matched (1-4 months). Ginger and chamomile were both significantly effective for reducing the frequency of vomiting, there being no significant difference between the ginger and chamomile groups. Moreover, unlike the chamomile, ginger significantly influenced the frequency of nausea. According to the findings of this study, it should be declared that taking ginger capsules (1 g/day) might relieve CINV safely. Nurses dealing directly with cancer patients should be responsible for providing educational programs for patients and their families about how to deal with their drug regimens and associated side effects.
Lorenz, Ralph D; Cabrol, Nathalie A
2018-05-01
A scale model of the proposed Titan Mare Explorer capsule was deployed at the Planetary Lake Lander field site at Laguna Negra, Chile. The tests served to calibrate models of wind-driven drift of the capsule and to understand its attitude motion in the wave field, as well as to identify dynamic and acoustic signatures of shoreline approach. This information enables formulation of onboard trigger criteria for near-shore science data acquisition. Key Words: Titan-Vehicle dynamics-Science autonomy-Lake. Astrobiology 18, 607-618.
Short article: Aspiration of capsule endoscopes: a comprehensive review of the existing literature.
Yung, Diana E; Plevris, John N; Koulaouzidis, Anastasios
2017-04-01
Capsule endoscopy (CE) has an excellent safety profile. Although retention is the most cited complication, capsule aspiration is less frequent and is often reported only as isolated cases. This study represents a systematic effort to compile and scrutinize the available data on capsule aspiration to provide comprehensive and conclusive information on this CE complication. A systematic literature search was performed in PubMed, Embase and Chinese National Knowledge Infrastructure. The search terms used were 'capsule endoscopy' AND 'aspiration' (both terms searched as keyword and MeSH). We included case reports and/or series on capsule aspiration, as well as observational cohort studies that reported capsule aspiration among their complications/outcomes. Thirty-four case reports with 37 cases of capsule aspiration were identified. A further four observational studies reported aspiration as part of a cohort of patients undergoing CE. 94.6% of aspirations occurred in elderly men. 87.1% had significant comorbidities. 59.5% had symptoms on aspiration, with cough reported most frequently. The most common location of aspiration was the right main bronchus. Half of the patients required intervention for capsule retrieval; bronchoscopy was the most common management, with good effect. There was a single fatality following capsule aspiration, not directly related to the procedure, and one case of aspiration pneumonia. Outcomes were good for all other patients. The estimated overall aspiration rate is 0.1%. Although very rare and generally safely managed, capsule aspiration should be anticipated in certain patient groups and capsule administration should be approached with necessary precautions.
NASA Astrophysics Data System (ADS)
Samuel, R.; Thacker, C. M.; Maricq, A. V.; Gale, B. K.
2014-09-01
We present a new fabrication protocol for fabricating pneumatically controlled microvalve arrays (consisting of 100 s of microvalves) in PDMS substrates. The protocol utilizes rapid and cost-effective fabrication of molds using laser cutting of adhesive vinyl tapes and replica molding of PDMS. Hence the protocol is fast, simple and avoids cleanroom use. The results show that effective doormat-style microvalves can be easily fabricated in arrays by manipulating the stiffness of the actuating membrane through varying the valve-chamber area/shape. Three frequently used valve-chamber shapes (circle, square and capsule) were tested and all showed advantages in different situations. Circular valve chambers were best for small valves, square valves were best for medium-sized valves, and the capsule valves were best for larger valves. An application of this protocol has been demonstrated in the fabrication of a microfluidic 32-well plate for high-throughput manipulation of C. elegans for biomedical research.
NASA Astrophysics Data System (ADS)
Simarmata, M.; Halim, B.; Ardinata, D.
2018-03-01
Primary dysmenorrhea is a gynecological disorder which most commonly occurs like a pain in the initial menstruation. One ofthe attempts to handle dysmenorrhea is by using anon-pharmacological method such as herbal therapy which uses red ginger. The research was at Akbid and Akper Harapan Mama, Deli Serdang Regency, with pre-experimental design and one group pretest-posttest. The samples were 32 female students as the respondents, taken by using non-probability or consecutive sampling technique. PGF2a content measurement by ELISA, theintensity of pain by Visual Analogue Scale and analyzed by using Wilcoxon test. PGF2α content before giving red ginger capsule supplement median was 156.50 pg/ml (min-max: 57-1037 pg/ml), after giving it was 101 (min-max: 22-785), pain intensity before giving it in the mean score of 2 was 15 respondents (47%), after giving it in the mean score of 0 was 14 respondents (44%). The result of statistic test on PGF2α content before and after giving it was p-value = 0.001, and pain intensity before and after giving it was p < 0.001 which indicated that there was asignificant decrease in PGF2α and pain intensity after giving it. Red ginger capsule supplement could decrease PGF2α content during primary dysmenorrhea.
2012-08-03
CAPE CANAVERAL, Fla. – Lockheed Martin's Jules Schneider, right, shows details of the preparation hardware used for the Orion capsule to Charles Bolden, NASA administrator, center. The Orion capsule will make an uncrewed flight test in 2014. The spacecraft is in the high bay at the Operations and Checkout Building at NASA's Kennedy Space Center in Florida. Photo credit: NASA/Kim Shifflett
Aerodynamics of electrically driven freight pipeline system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lundgren, T.S.; Zhao, Y.
2000-06-01
This paper examines the aerodynamic characteristics of a freight pipeline system in which freight capsules are individually propelled by electrical motors. The fundamental difference between this system and the more extensively studied pneumatic capsule pipeline is the different role played by aerodynamic forces. In a driven system the propelled capsules are resisted by aerodynamic forces and, in reaction, pump air through the tube. In contrast, in a pneumatically propelled system external blowers pump air through the tubes, and this provides the thrust for the capsules. An incompressible transient analysis is developed to study the aerodynamics of multiple capsules in amore » cross-linked two-bore pipeline. An aerodynamic friction coefficient is used as a cost parameter to compare the effects of capsule blockage and headway and to assess the merits of adits and vents. The authors conclude that optimum efficiency for off-design operation is obtained with long platoons of capsules in vented or adit connected tubes.« less
Albert, Jörg; Göbel, Christa-Maria; Lesske, Joachim; Lotterer, Erich; Nietsch, Hubert; Fleig, Wolfgang E
2004-04-01
Capsule endoscopy is a new imaging method for visualization of the entire small bowel. However, no standardized protocol for bowel preparation for capsule endoscopy has been evaluated. Capsule endoscopy was performed in 36 consecutive patients, all of whom fasted for 12 hours before ingestion of the capsule. Before capsule endoscopy, 18 patients received 80 mg simethicone and 18 had no supplemental medication for bowel preparation. Two observers, both experienced endoscopists, independently reviewed the examinations in a single-blinded and randomly assigned fashion. Mucosal visibility and intraluminal gas bubbles were assessed and graded by both observers. Bowel preparation with simethicone resulted in significantly better visibility because of fewer intraluminal bubbles (p<0.01). Interobserver agreement was excellent (r>/=0.8; k 0.78: 95% CI[0.57, 0.98] ). No adverse effect of simethicone was observed. Simethicone may be added to the routine preparation for capsule endoscopy to improve the visibility of small bowel mucosa.
SpaceX Dragon Air Circulation System
NASA Technical Reports Server (NTRS)
Hernandez, Brenda; Piatrovich, Siarhei; Prina, Mauro
2011-01-01
The Dragon capsule is a reusable vehicle being developed by Space Exploration Technologies (SpaceX) that will provide commercial cargo transportation to the International Space Station (ISS). Dragon is designed to be a habitable module while it is berthed to ISS. As such, the Dragon Environmental Control System (ECS) consists of pressure control and pressure equalization, air sampling, fire detection, illumination, and an air circulation system. The air circulation system prevents pockets of stagnant air in Dragon that can be hazardous to the ISS crew. In addition, through the inter-module duct, the air circulation system provides fresh air from ISS into Dragon. To utilize the maximum volume of Dragon for cargo packaging, the Dragon ECS air circulation system is designed around cargo rack optimization. At the same time, the air circulation system is designed to meet the National Aeronautics Space Administration (NASA) inter-module and intra-module ventilation requirements and acoustic requirements. A flight like configuration of the Dragon capsule including the air circulation system was recently assembled for testing to assess the design for inter-module and intra-module ventilation and acoustics. The testing included the Dragon capsule, and flight configuration in the pressure section with cargo racks, lockers, all of the air circulation components, and acoustic treatment. The air circulation test was also used to verify the Computational Fluid Dynamics (CFD) model of the Dragon capsule. The CFD model included the same Dragon internal geometry that was assembled for the test. This paper will describe the Dragon air circulation system design which has been verified by testing the system and with CFD analysis.
Zhang, Ziying; Du, Jun; Wei, Zhengying; Wang, Zhen; Li, Minghui
2018-02-01
Cellular adhesion plays a critical role in biological systems and biomedical applications. Cell deformation and biophysical properties of adhesion molecules are of significance for the adhesion behavior. In the present work, dynamic adhesion of a deformable capsule to a planar substrate, in a linear shear flow, is numerically simulated to investigate the combined influence of membrane deformability (quantified by the capillary number) and bond formation/dissociation rates on the adhesion behavior. The computational model is based on the immersed boundary-lattice Boltzmann method for the capsule-fluid interaction and a probabilistic adhesion model for the capsule-substrate interaction. Three distinct adhesion states, detachment, rolling adhesion and firm adhesion, are identified and presented in a state diagram as a function of capillary number and bond dissociation rate. The impact of bond formation rate on the state diagram is further investigated. Results show that the critical bond dissociation rate for the transition of rolling or firm adhesion to detachment is strongly related to the capsule deformability. At the rolling-adhesion state, smaller off rates are needed for larger capillary number to increase the rolling velocity and detach the capsule. In contrast, the critical off rate for firm-to-detach transition slightly increases with the capillary number. With smaller on rate, the effect of capsule deformability on the critical off rates is more pronounced and capsules with moderate deformability are prone to detach by the shear flow. Further increasing of on rate leads to large expansion of both rolling-adhesion and firm-adhesion regions. Even capsules with relatively large deformability can maintain stable rolling adhesion at certain off rate.
Bowtle, William; Kanyowa, Lionel; Mackenzie, Mark; Higgins, Paul
2011-06-01
The industrial take-up of liquid-fill hard capsule technology is limited in part by lack of published long-term physical and chemical stability data which demonstrate the robustness of the system. To assess the effects of extreme long-term storage on liquid-fill capsule product quality and integrity, with respect to both the capsules per se and a standard blister-pack type (foil-film blister). Fourteen sets of stored peroxidation-sensitive liquid-fill hard gelatin capsule product samples, originating ~20 years from the current study, were examined with respect to physical and selected chemical properties, together with microbiological evaluation. All sets retained physical integrity of capsules and blister-packs. Capsules were free of leaks, gelatin cross-linking, and microbiological growth. Eight samples met a limit (anisidine value, 20) commonly used as an index of peroxidation for lipid-based products with shelf lives of 2-3 years. Foil-film blister-packs using PVC or PVC-PVdC as the thermoforming film were well-suited packaging components for the liquid-fill capsule format. The study confirms the long-term physical robustness of the liquid-fill hard capsule format, together with its manufacturing and banding processes. It also indicates that various peroxidation-sensitive products using the capsule format may be maintained satisfactorily over very prolonged storage periods.
Biomimetic/Bioinspired Design of Enzyme@capsule Nano/Microsystems.
Shi, J; Jiang, Y; Zhang, S; Yang, D; Jiang, Z
2016-01-01
Enzyme@capsule nano/microsystems, which refer to the enzyme-immobilized capsules, have received tremendous interest owing to the combination of the high catalytic activities of encapsulated enzymes and the hierarchical structure of the capsule. The preparation of capsules and simultaneous encapsulation of enzymes is recognized as the core process for the rational design and construction of enzyme@capsule nano/microsystems. The strategy used has three major steps: (a) generation of the templates, (b) surface coating on the templates, and (c) removal of the templates, and it has been proven to be effective and versatile for the construction of enzyme@capsule nano/microsystems. Several conventional methods, including layer-by-layer assembly of polyelectrolytes, liquid crystalline templating method, etc., were used to design and construct enzyme@capsule nano/microsystems, but these have two major drawbacks. One is the low mechanical stability of the systems and the second is the harsh conditions used in the construction process. Learning from nature, several biomimetic/bioinspired methods such as biomineralization, biomimetic/bioinspired adhesion, and their combination have been exploited for the construction of enzyme@capsule nano/microsystems. In this chapter, we will present a general protocol for the construction of enzyme@capsule nano/microsystems using the latter approach. Some suggestions for improved design, construction, and characterization will also be presented with detailed procedures for specific examples. © 2016 Elsevier Inc. All rights reserved.
Design and landing dynamic analysis of reusable landing leg for a near-space manned capsule
NASA Astrophysics Data System (ADS)
Yue, Shuai; Nie, Hong; Zhang, Ming; Wei, Xiaohui; Gan, Shengyong
2018-06-01
To improve the landing performance of a near-space manned capsule under various landing conditions, a novel landing system is designed that employs double chamber and single chamber dampers in the primary and auxiliary struts, respectively. A dynamic model of the landing system is established, and the damper parameters are determined by employing the design method. A single-leg drop test with different initial pitch angles is then conducted to compare and validate the simulation model. Based on the validated simulation model, seven critical landing conditions regarding nine crucial landing responses are found by combining the radial basis function (RBF) surrogate model and adaptive simulated annealing (ASA) optimization method. Subsequently, the adaptability of the landing system under critical landing conditions is analyzed. The results show that the simulation effectively results match the test results, which validates the accuracy of the dynamic model. In addition, all of the crucial responses under their corresponding critical landing conditions satisfy the design specifications, demonstrating the feasibility of the landing system.
Pharmacokinetics of propafenone hydrochloride sustained-release capsules in male beagle dogs.
Pan, Liping; Qian, Yafang; Cheng, Minlu; Gu, Pan; He, Yanna; Xu, Xiaowen; Ding, Li
2015-01-01
This paper describes the development and validation of a liquid chromatography-mass spectrometric assay for propafenone and its application to a pharmacokinetic study of propafenone administered as a new propafenone hydrochloride sustained-release capsule (SR-test), as an instant-release tablet (IR-reference) and as the market leader sustained-release capsule (Rythmol, SR-reference) in male beagle dogs (n=8). In Study A comparing SR-test with IR-reference in a crossover design T max and t 1/2 of propafenone for SR-test were significantly higher than those for IR-reference while C max and AUC were lower demonstrating the sustained release properties of the new formulation. In Study B comparing SR-test with SR-reference the observed C max and AUC of propafenone for SR-test (124.5±140.0 ng/mL and 612.0±699.2 ng·h/mL, respectively) were higher than for SR-reference (78.52±72.92 ng/mL and 423.6±431.6 ng·h/mL, respectively) although the differences were not significant. Overall, the new formulation has as good if not better sustained release characteristics to the market leader formulation.
Controversies in colorectal cancer screening.
Pox, Christian P
2014-01-01
Colorectal cancer (CRC) is one of the most common cancers worldwide and a good candidate for screening programmes. However, there is controversy concerning which of the available screening tests should be used. There is general agreement that screening for CRC in the asymptomatic population should begin at the age of 50. Several different screening methods are available which can be separated into those that mainly detect cancers: faecal occult blood tests [guaiac (FOBT) and immunochemical (FIT)], genetic stool tests, blood tests and the M2-pyruvate kinase (M2-PK) test. Methods that detect cancers and polyps are colonoscopy, sigmoidoscopy, CT-colonography (CT-C) and colon capsule endoscopy. The only tests for which a reduction in CRC mortality compared to no screening have been proven in randomized trials are FOBT and sigmoidoscopy. Several trials suggest that FIT are superior to FOBT in terms of detection rates of cancers and advanced adenomas and possibly compliance. There is indirect evidence suggesting efficacy of colonoscopy as a screening test. The role of CT-C is controversial. There is data suggesting a good sensitivity for neoplasia >9 mm with a lower sensitivity for smaller neoplasia. However, radiation exposure is considered a major limitation in some countries. Unresolved questions include the lesion cut-off for referral to colonoscopy and work-up of extracolonic findings. For other methods, like genetic stool testing using newer markers, blood tests, capsule endoscopy and M2-PK, there is currently insufficient data on screening of the asymptomatic population. Key Messages: Colorectal screening is recommended and should be performed in the form of an organized programme. If detection of early-stage cancers is the aim of a screening programme, FIT seem to be superior to FOBT. If detection and removal of adenomas is the aim of a screening programme, endoscopic methods seem to be good alternatives. Sigmoidoscopy is easier to perform but will likely only have an effect on distal cancers. Colonoscopy is more invasive but enables inspection of the whole colon. The role of CT-C, capsule endoscopy, genetic stool tests, blood tests and M2-PK is currently unknown. © 2014 S. Karger AG, Basel.
Mesa, Luz Estella; Vasquez, Daniel; Lutgen, Pierre; Vélez, Iván Darío; Restrepo, Adriana María; Ortiz, Isabel; Robledo, Sara María
2017-01-01
Cutaneous leishmaniasis (CL) is a tropical disease that affects millions of individuals worldwide. The current drugs for CL may be effective but have serious side effects; hence, alternatives are urgently needed. Although plant-derived materials are used for the treatment of various diseases in 80% of the global population, the validation of these products is essential. Gelatin capsules containing dried Artemisia annua leaf powder were recently developed as a new herbal formulation (totum) for the oral treatment of malaria and other parasitic diseases. Here, we aimed to determine the usefulness of A. annua gel capsules in CL. The antileishmanial activity and cytotoxicity of A. annua L. capsules was determined via in vitro and in vivo studies. Moreover, a preliminary evaluation of its therapeutic potential as antileishmanial treatment in humans was conducted in 2 patients with uncomplicated CL. Artemisia annua capsules showed moderate in vitro activity in amastigotes of Leishmania (Viannia) panamensis; no cytotoxicity in U-937 macrophages or genotoxicity in human lymphocytes was observed. Five of 6 (83.3%) hamsters treated with A. annua capsules (500mg/kg/day) for 30 days were cured, and the 2 examined patients were cured 45 days after initiation of treatment with 30g of A. annua capsules, without any adverse reactions. Both patients remained disease-free 26 and 24 months after treatment completion. Capsules of A. annua L. represent an effective treatment for uncomplicated CL, although further randomized controlled trials are needed to validate its efficacy and safety.
Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth
2013-01-01
Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD < 1.5 µm, FPF<5µm/ED > 90%, and ED > 80%. PMID:23949304
Effect of sodium lauryl sulfate in dissolution media on dissolution of hard gelatin capsule shells.
Zhao, Fang; Malayev, Vyacheslav; Rao, Venkatramana; Hussain, Munir
2004-01-01
Sodium lauryl sulfate (SLS) is a commonly used surfactant in dissolution media for poorly water soluble drugs. However, it has occasionally been observed that SLS negatively impacts the dissolution of drug products formulated in gelatin capsules. This study investigated the effect of SLS on the dissolution of hard gelatin capsule shells. The USP paddle method was used with online UV monitoring at 214 nm (peptide bond). Empty size #0 capsule shells were held to the bottom of the dissolution vessel by magnetic three-prong sinkers. SLS significantly slowed down the dissolution of gelatin shells at pH < 5. Visually, the gelatin shells transformed into some less-soluble precipitate under these conditions. This precipitate was found to contain a higher sulfur content than the gelatin control sample by elemental analysis, indicating that SLS is part of the precipitate. Additionally, the slowdown of capsule shell dissolution was shown to be dependent on the SLS concentration and the ionic strength of the media. SLS interacts with gelatin to form a less-soluble precipitate at pH < 5. The use of SLS in dissolution media at acidic pH should be carefully evaluated for gelatin capsule products.
Araujo, Juliana Milani; de Araújo, Jackson Victor; Braga, Fabio Ribeiro; Carvalho, Rogério Oliva; Ferreira, Sebastião Rodrigo
2009-12-03
Nematophagous fungi are potential biological control agents of helminths. The in vitro ovicidal effect of four isolates of the nematophagous fungi Pochonia chlamydosporia (VC1 and VC4), Duddingtonia flagrans (AC001) and Monacrosporium thaumasium (NF34) was evaluated on egg capsules of Dipylidium caninum, a cestode parasite of dogs, cats and humans. One thousand egg capsules of D. caninum were plated on 2% water-agar with the grown isolates and control without fungus. The ovicidal activity of these fungi was evaluated 5, 10 and 15 days after incubation. Only P. chlamydosporia showed ovicidal activity (p<0.05) on D. caninum egg capsules, of 19.6% (VC1) and 20% (VC4) on the 5th day; 44.2% (VC1) and 31.5% (VC4) on the 10th day; and 49.2% (VC1) and 41.9% (VC4) on the 15th day. D. flagrans and M. thaumasium caused no morphological damage to egg capsules. The results demonstrated that P. chlamydosporia was in vitro effective against capsules and eggs of D. caninum, and can be considered as a potential biological control agent for this helminth.
WESF (173)Cs gamma ray sources
NASA Astrophysics Data System (ADS)
Kenna, B. T.
1984-10-01
The Waste Encapsulation and Storage Facility (WESP) at Hanford, Washington has been separating cesium from stored liquid defense waste since 1945. This is done to alleviate the heat generated by the decay of radioactive Cs137. The cesium is converted to CsCl, doubly encapsulated in 316l stainless steel, and placed in storage. The potential utility of these Cs137 capsules as gamma radiation sources was demonstrated. Registration of the capsule with the NRC as a sealed gamma source would facilitate the licensing of non-DOE irradiation facilities using this source. To grant this registration, the NRC requires characteristics of the capsule. It must also be demonstrated that the capsule will maintain its integrity under both normal circumstances and specified abnormal conditions. The required information is provided through collation of results of studies and tests done previously by other laboratories.
High performance capsule implosions on the OMEGA Laser facility with rugby hohlraumsa)
NASA Astrophysics Data System (ADS)
Robey, H. F.; Amendt, P.; Park, H.-S.; Town, R. P. J.; Milovich, J. L.; Döppner, T.; Hinkel, D. E.; Wallace, R.; Sorce, C.; Strozzi, D. J.; Philippe, F.; Casner, A.; Caillaud, T.; Landoas, O.; Liberatore, S.; Monteil, M.-C.; Séguin, F.; Rosenberg, M.; Li, C. K.; Petrasso, R.; Glebov, V.; Stoeckl, C.; Nikroo, A.; Giraldez, E.
2010-05-01
Rugby-shaped hohlraums have been proposed as a method for x-ray drive enhancement for indirectly driven capsule implosions. This concept has recently been tested in a series of shots on the OMEGA laser facility [T. R. Boehly, D. L. Brown, R. S. Craxton et al., Opt. Commun. 133, 495 (1997)]. In this paper, experimental results are presented comparing the performance of D2-filled capsules between standard cylindrical Au hohlraums and rugby-shaped hohlraums. The rugby hohlraums demonstrated 18% more x-ray drive energy as compared with the cylinders, and the high-performance design of these implosions (both cylinder and rugby) also provided ≈20× more deuterium (DD) neutrons than any previous indirectly driven campaign on OMEGA and ≈3× more than ever achieved on NOVA [E. M. Campbell, Laser Part. Beams 9, 209 (1991)] implosions driven with nearly twice the laser energy. This increase in performance enables, for the first time, a measurement of the neutron burn history and imaging of the neutron core shapes in an indirectly driven implosion. Previous DD neutron yields had been too low to register this key measurement of capsule performance and the effects of dynamic mix. A wealth of additional data on the fuel areal density from the suite of charged particle diagnostics was obtained on a subset of the shots that used D H3e rather than D2 fuel. Comparisons of the experimental results with numerical simulations are shown to be in very good agreement. The design techniques employed in this campaign, e.g., smaller laser entrance holes and hohlraum case-to-capsule ratios, provide added confidence in the pursuit of ignition on the National Ignition Facility [J. D. Lindl, P. Amendt, R. L. Berger et al., Phys. Plasmas 11, 339 (2004)].
High Performance Capsule Implosions on the Omega Laser Facility with Rugby Hohlraums
NASA Astrophysics Data System (ADS)
Robey, Harry F.
2009-11-01
Rugby-shaped hohlraums have been proposed as a method for x-ray drive enhancement for indirectly-driven capsule implosions [1]. This concept has recently been tested in a series of shots on the OMEGA laser facility at the Laboratory for Laser Energetics at the University of Rochester. In this talk, experimental results are presented comparing the performance of D2-filled capsules between standard cylindrical Au hohlraums and rugby-shaped hohlraums. Not only did the rugby hohlraums demonstrate 18% more x-ray drive energy as compared with the cylinders, but the high-performance design of these implosions (both cylinder and rugby) also provided 20X more DD neutrons than any previous indirectly-driven campaign on Omega (and 3X more than ever achieved on Nova implosions driven with nearly twice the laser energy). This increase in performance enables, for the first time, a measurement of the neutron burn history of an indirectly-driven implosion. Previous DD neutron yields had been too low to register this key measurement of capsule performance and the effects of dynamic mix. A wealth of additional data on the fuel areal density from the suite of charged particle diagnostics was obtained on a subset of the shots that used D^3He rather than D2 fuel. Comparisons of the experimental results with numerical simulations are shown to be in excellent agreement. The design techniques employed in this campaign, e.g., smaller NIF-like laser entrance holes and hohlraum case-to-capsule ratios, provide added confidence in the pursuit of ignition on the National Ignition Facility. [4pt] [1] P. Amendt, C. Cerjan, D. E. Hinkel, J. L. Milovich, H.-S. Park, and H. F. Robey, ``Rugby-like hohlraum experimental designs for demonstrating x-ray drive enhancement'', Phys. Plasmas 15, 012702 (2008).
Greater vertical spot spacing to improve femtosecond laser capsulotomy quality.
Schultz, Tim; Joachim, Stephanie C; Noristani, Rozina; Scott, Wendell; Dick, H Burkhard
2017-03-01
To evaluate the effect of adapted capsulotomy laser settings on the cutting quality in femtosecond laser-assisted cataract surgery. Ruhr-University Eye Clinic, Bochum, Germany. Prospective randomized case series. Eyes were treated with 1 of 2 laser settings. In Group 1, the regular standard settings were used (incisional depth 600 μm, pulse energy 4 μJ, horizontal spot spacing 5 μm, vertical spot spacing 10 μm, treatment time 1.2 seconds). In Group 2, vertical spot spacing was increased to 15 μm and the treatment time was 1.0 seconds. Light microscopy was used to evaluate the cut quality of the capsule edge. The size and number of tags (misplaced laser spots, which form a second cut of the capsule with high tear risk) were evaluated in a blinded manner. Groups were compared using the Mann-Whitney U test. The study comprised 100 eyes (50 eyes in each group). Cataract surgery was successfully completed in all eyes, and no anterior capsule tear occurred during the treatment. Histologically, significant fewer tags were observed with the new capsulotomy laser setting. The mean score for the number and size of free tags was significantly lower in this group than with the standard settings (P < .001). The new laser settings improved cut quality and reduced the number of tags. The modification has the potential to reduce the risk for radial capsule tears in femtosecond laser-assisted cataract surgery. With the new settings, no tags and no capsule tears were observed under the operating microscope in any eye. Copyright © 2017 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.
Video-based measurements for wireless capsule endoscope tracking
NASA Astrophysics Data System (ADS)
Spyrou, Evaggelos; Iakovidis, Dimitris K.
2014-01-01
The wireless capsule endoscope is a swallowable medical device equipped with a miniature camera enabling the visual examination of the gastrointestinal (GI) tract. It wirelessly transmits thousands of images to an external video recording system, while its location and orientation are being tracked approximately by external sensor arrays. In this paper we investigate a video-based approach to tracking the capsule endoscope without requiring any external equipment. The proposed method involves extraction of speeded up robust features from video frames, registration of consecutive frames based on the random sample consensus algorithm, and estimation of the displacement and rotation of interest points within these frames. The results obtained by the application of this method on wireless capsule endoscopy videos indicate its effectiveness and improved performance over the state of the art. The findings of this research pave the way for a cost-effective localization and travel distance measurement of capsule endoscopes in the GI tract, which could contribute in the planning of more accurate surgical interventions.
Hyperspectral techniques in analysis of oral dosage forms.
Hamilton, Sara J; Lowell, Amanda E; Lodder, Robert A
2002-10-01
Pharmaceutical oral dosage forms are used in this paper to test the sensitivity and spatial resolution of hyperspectral imaging instruments. The first experiment tested the hypothesis that a near-infrared (IR) tunable diode-based remote sensing system is capable of monitoring degradation of hard gelatin capsules at a relatively long distance (0.5 km). Spectra from the capsules were used to differentiate among capsules exposed to an atmosphere containing 150 ppb formaldehyde for 0, 2, 4, and 8 h. Robust median-based principal component regression with Bayesian inference was employed for outlier detection. The second experiment tested the hypothesis that near-IR imaging spectrometry of tablets permits the identification and composition of multiple individual tablets to be determined simultaneously. A near-IR camera was used to collect thousands of spectra simultaneously from a field of blister-packaged tablets. The number of tablets that a typical near-IR camera can currently analyze simultaneously was estimated to be approximately 1300. The bootstrap error-adjusted single-sample technique chemometric-imaging algorithm was used to draw probability-density contour plots that revealed tablet composition. The single-capsule analysis provides an indication of how far apart the sample and instrumentation can be and still maintain adequate signal-to-noise ratio (S/N), while the multiple-tablet imaging experiment gives an indication of how many samples can be analyzed simultaneously while maintaining an adequate S/N and pixel coverage on each sample.
Positron radiography of ignition-relevant ICF capsules
NASA Astrophysics Data System (ADS)
Williams, G. J.; Chen, Hui; Field, J. E.; Landen, O. L.; Strozzi, D. J.
2017-12-01
Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 × 1012 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2 g/cm2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. We evaluate the effects of magnetic fields near the capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-04
... discontinued from marketing for reasons other than safety or effectiveness. ANDAs that refer to ALOXI... Sale for Reasons of Safety or Effectiveness AGENCY: Food and Drug Administration, HHS. ACTION: Notice...)) Capsules, 0.5 milligram (mg) (base), were not withdrawn from sale for reasons of safety or effectiveness...
2012-08-03
CAPE CANAVERAL, Fla. – Lockheed Martin's Jules Schneider, right, shows the upper portion of the Orion capsule to Charles Bolden, NASA administrator, center, as NASA's Scott Wilson looks on. The Orion capsule will make an uncrewed flight test in 2014. The spacecraft is in the high bay at the Operations and Checkout Building at NASA's Kennedy Space Center in Florida. Photo credit: NASA/Kim Shifflett
2012-08-03
CAPE CANAVERAL, Fla. – Lockheed Martin's Jules Schneider, right, shows the upper portion of the Orion capsule to Charles Bolden, NASA administrator, center, as NASA's Scott Wilson looks on. The Orion capsule will make an uncrewed flight test in 2014. The spacecraft is in the high bay at the Operations and Checkout Building at NASA's Kennedy Space Center in Florida. Photo credit: NASA/Kim Shifflett
Aerodynamics for the Mars Phoenix Entry Capsule
NASA Technical Reports Server (NTRS)
Edquist, Karl T.; Desai, Prasun N.; Schoenenberger, Mark
2008-01-01
Pre-flight aerodynamics data for the Mars Phoenix entry capsule are presented. The aerodynamic coefficients were generated as a function of total angle-of-attack and either Knudsen number, velocity, or Mach number, depending on the flight regime. The database was constructed using continuum flowfield computations and data from the Mars Exploration Rover and Viking programs. Hypersonic and supersonic static coefficients were derived from Navier-Stokes solutions on a pre-flight design trajectory. High-altitude data (free-molecular and transitional regimes) and dynamic pitch damping characteristics were taken from Mars Exploration Rover analysis and testing. Transonic static coefficients from Viking wind tunnel tests were used for capsule aerodynamics under the parachute. Static instabilities were predicted at two points along the reference trajectory and were verified by reconstructed flight data. During the hypersonic instability, the capsule was predicted to trim at angles as high as 2.5 deg with an on-axis center-of-gravity. Trim angles were predicted for off-nominal pitching moment (4.2 deg peak) and a 5 mm off-axis center-ofgravity (4.8 deg peak). Finally, hypersonic static coefficient sensitivities to atmospheric density were predicted to be within uncertainty bounds.
A sealed capsule system for biological and liquid shock-recovery experiments.
Leighs, James A; Appleby-Thomas, Gareth J; Stennett, Chris; Hameed, Amer; Wilgeroth, James M; Hazell, Paul J
2012-11-01
This paper presents an experimental method designed to one-dimensionally shock load and subsequently recover liquid samples. Resultant loading profiles have been interrogated via hydrocode simulation as the nature of the target did not allow for direct application of the diagnostics typically employed in shock physics (e.g., manganin stress gauges or Heterodyne velocimeter (Het-V)). The target setup has been experimentally tested using aluminium flyer plates accelerated by a 50-mm bore single-stage gas-gun reaching projectile impact velocities of up to ~500 ms(-1) (corresponding to peak pressures of up to ca. 4 GPa being experienced by fluid samples). Recovered capsules survived well showing only minor signs of damage. Modelled gauge traces have been validated through the use of a (slightly modified) experiment in which a Het-V facing the rear of the inner capsule was employed. In these tests, good correlation between simulated and experimental traces was observed.
A sealed capsule system for biological and liquid shock-recovery experiments
NASA Astrophysics Data System (ADS)
Leighs, James A.; Appleby-Thomas, Gareth J.; Stennett, Chris; Hameed, Amer; Wilgeroth, James M.; Hazell, Paul J.
2012-11-01
This paper presents an experimental method designed to one-dimensionally shock load and subsequently recover liquid samples. Resultant loading profiles have been interrogated via hydrocode simulation as the nature of the target did not allow for direct application of the diagnostics typically employed in shock physics (e.g., manganin stress gauges or Heterodyne velocimeter (Het-V)). The target setup has been experimentally tested using aluminium flyer plates accelerated by a 50-mm bore single-stage gas-gun reaching projectile impact velocities of up to ˜500 ms-1 (corresponding to peak pressures of up to ca. 4 GPa being experienced by fluid samples). Recovered capsules survived well showing only minor signs of damage. Modelled gauge traces have been validated through the use of a (slightly modified) experiment in which a Het-V facing the rear of the inner capsule was employed. In these tests, good correlation between simulated and experimental traces was observed.
2012-04-29
CAPE CANAVERAL, Fla. - The SpaceX Falcon 9 rocket arrives at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians close the hatch of the Dragon capsule. The hatch was open for cargo to be stowed in the capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – The 227-foot-tall 69.2 meter) SpaceX Falcon 9 rocket arrives at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – The SpaceX Falcon 9 rocket stands at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – The SpaceX Falcon 9 rocket stands at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-05-17
CAPE CANAVERAL, Fla. – The SpaceX Falcon 9 rocket makes its way to the pad at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – Under the watchful eye of technicians, the SpaceX Falcon 9 rocket arrives at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-04-04
CAPE CANAVERAL, Fla. – In a processing hangar at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida, Space Exploration Technologies technicians prepare to close the hatch of the Dragon capsule. The hatch was open for cargo to be stowed in the capsule in preparation for its scheduled April 30 liftoff aboard a Falcon 9 rocket. Known as SpaceX, the launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services program, or COTS. During the flight, the capsule will conduct a series of checkout procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. The cargo includes food and provisions for the station’s Expedition crews, such as clothing, batteries, and computer equipment. Under COTS, NASA has partnered with two private companies to launch cargo safely to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – The SpaceX Falcon 9 rocket stands at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – The 227-foot-tall 69.2 meter) SpaceX Falcon 9 rocket stands at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – In this nose-on view, the SpaceX Falcon 9 rocket arrives at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
The Wireless Motility Capsule: a One-Stop Shop for the Evaluation of GI Motility Disorders.
Saad, Richard J
2016-03-01
The wireless motility and pH capsule (WMC) provides an office-based test to simultaneously assess both regional and whole gut transit. Ingestion of this non-digestible capsule capable of measuring temperature, pH, and the pressure of its immediate surroundings allows for the measurement of gastric, small bowel, and colonic transit times in an ambulatory setting. Approved by the US Food and Drug Administration for the evaluation of suspected conditions of delayed gastric emptying and the evaluation of colonic transit in chronic idiopathic constipation, WMC should be considered in suspected gastrointestinal motility disorders as it provides a single study capable of simultaneously assessing for regional, multiregional, or generalized motility disorders. Specific indications for testing with the WMC should include the evaluation of suspect cases of gastroparesis, small bowel dysmotility, and slow transit constipation, as well as symptom syndromes suggestive of a multiregional or generalized gastrointestinal transit delay.
The Anterolateral Capsule of the Knee Behaves Like a Sheet of Fibrous Tissue.
Guenther, Daniel; Rahnemai-Azar, Amir A; Bell, Kevin M; Irarrázaval, Sebastián; Fu, Freddie H; Musahl, Volker; Debski, Richard E
2017-03-01
The function of the anterolateral capsule of the knee has not been clearly defined. However, the contribution of this region of the capsule to knee stability in comparison with other anterolateral structures can be determined by the relative force that each structure carries during loading of the knee. Purpose/Hypothesis: The purpose of this study was to determine the forces in the anterolateral structures of the intact and anterior cruciate ligament (ACL)-deficient knee in response to an anterior tibial load and internal tibial torque. It was hypothesized that the anterolateral capsule would not function like a traditional ligament (ie, transmitting forces only along its longitudinal axis). Controlled laboratory study. Loads (134-N anterior tibial load and 7-N·m internal tibial torque) were applied continuously during flexion to 7 fresh-frozen cadaveric knees in the intact and ACL-deficient state using a robotic testing system. The lateral collateral ligament (LCL) and the anterolateral capsule were separated from the surrounding tissue and from each other. This was done by performing 3 vertical incisions: lateral to the LCL, medial to the LCL, and lateral to the Gerdy tubercle. Attachments of the LCL and anterolateral capsule were detached from the underlying tissue (ie, meniscus), leaving the insertions and origins intact. The force distribution in the anterolateral capsule, ACL, and LCL was then determined at 30°, 60°, and 90° of knee flexion using the principle of superposition. In the intact knee, the force in the ACL in response to an anterior tibial load was greater than that in the other structures ( P < .001). However, in response to an internal tibial torque, no significant differences were found between the ACL, LCL, and forces transmitted between each region of the anterolateral capsule after capsule separation. The anterolateral capsule experienced smaller forces (~50% less) compared with the other structures ( P = .048). For the ACL-deficient knee in response to an anterior tibial load, the force transmitted between each region of the anterolateral capsule was 434% greater than was the force in the anterolateral capsule ( P < .001) and 54% greater than the force in the LCL ( P = .036) at 30° of flexion. In response to an internal tibial torque at 30°, 60°, or 90° of knee flexion, no significant differences were found between the force transmitted between each region of the anterolateral capsule and the LCL. The force in the anterolateral capsule was significantly smaller than that in the other structures at all knee flexion angles for both loading conditions ( P = .004 for anterior tibial load and P = .04 for internal tibial torque). The anterolateral capsule carries negligible forces in the longitudinal direction, and the forces transmitted between regions of the capsule were similar to the forces carried by the other structures at the knee, suggesting that it does not function as a traditional ligament. Thus, the anterolateral capsule should be considered a sheet of tissue. Surgical repair techniques for the anterolateral capsule should restore the ability of the tissue to transmit forces between adjacent regions of the capsule rather than along its longitudinal axis.
Yu, Zong-Yang; Liu, Zhi-Zhen; Ouyang, Xue-Nong; Du, Jian; Dai, Xi-Hu; Chen, Xi; Zhao, Zhong-Quan; Wang, Wen-Wu; Li, Jie
2012-02-01
To examine the effect of a Chinese medicinal herbal formula (Feitai Capsule, ) on the quality of life (QOL) and progression-free survival (PFS) of patients with unresectable non-small cell lung cancer (NSCLC). Sixty-two patients were randomly divided into the treatment group (31 cases) and the control group (31 cases). For the treatment group, 4 capsules (1.2 g/capsule) of Feitai Capsule were administered 3 times a day after meals for 3 weeks; then no drug was administered for 1 week. This schedule was continued for at least 3 more cycles (12 weeks totally). If there were no obvious toxic reactions, the treatment was extended. The patients were evaluated at least once every 8 weeks until progressive disease (PD). For the control group, the regular follow-up and evaluation were performed at least once every 8 weeks until PD. Clinical symptoms, objective response, physical constitution and energy, QOL, and PFS were evaluated regularly. Analysis of variance (ANOVA), a non-parametric test, and analysis of covariance were used to compare clinical features, amelioration of clinical symptoms, physical constitution and energy, and QOL. Kaplan-Meier analysis was used to compare the two-group PFS. Sixty patients finished the final evaluation, with 30 patients in each group. Baseline characters between groups were not significantly different (P>0.05). The control group had a 36.7% improvement in clinical symptoms, while the treatment group had a 73.3% improvement. This difference was statistically significant (Z= -2.632, P=0.008). The control group had a 26.7% improvement in the Karnofsky performance status (KPS), while the treatment group had a 53.4% improvement. This was also significantly different (Z=-2.182, P=0.029). A comparative analysis indicated a positive correlation (r=0.917, P<0.001). Compared with the control group, QOL in the treatment group was significantly improved, except in the social/family condition and doctor-patient relationship indicators. The PFS of the treatment group and control group were 6.23 months and 4.67 months, respectively (P=0.048). Feitai Capsule, a Chinese medicinal herbal treatment could improve the QOL and extend the PFS of the unresectable NSCLC patients.
Near infrared-modulated propulsion of catalytic Janus polymer multilayer capsule motors.
Wu, Yingjie; Si, Tieyan; Lin, Xiankun; He, Qiang
2015-01-11
The use of a near-infrared (NIR) laser for reversible modulation of a bubble-driven Janus polymer capsule motor is demonstrated. This process was mediated through illumination of the metal face of the Janus capsule motor at the critical concentration of peroxide fuel. Such an effective control of the propulsion of chemically powered microengines holds a considerable promise for diverse applications.
Correia, Clara R; Santos, Tírcia C; Pirraco, Rogério P; Cerqueira, Mariana T; Marques, Alexandra P; Reis, Rui L; Mano, João F
2017-04-15
Capsules coated with polyelectrolytes and co-encapsulating adipose stem (ASCs) and endothelial (ECs) cells with surface modified microparticles are developed. Microparticles and cells are freely dispersed in a liquified core, responsible to maximize the diffusion of essential molecules and allowing the geometrical freedom for the autonomous three-dimensional (3D) organization of cells. While the membrane wraps all the instructive cargo elements within a single structure, the microparticles provide a solid 3D substrate for the encapsulated cells. Our hypothesis is that inside this isolated biomimetic 3D environment, ECs would lead ASCs to differentiate into the osteogenic lineage to ultimately generate a mineralized tissue in vivo. For that, capsules encapsulating only ASCs (MONO capsules) or co-cultured with ECs (CO capsules) are subcutaneously implanted in nude mice up to 6weeks. Capsules implanted immediately after production or after 21days of in vitro osteogenic stimulation are tested. The most valuable outcome of the present study is the mineralized tissue in CO capsules without in vitro pre-differentiation, with similar levels compared to the pre-stimulated capsules in vitro. We believe that the proposed bioencapsulation strategy is a potent self-regulated system, which might find great applicability in bone tissue engineering. The diffusion efficiency of essential molecules for cell survival is a main issue in cell encapsulation. Former studies reported the superior biological outcome of encapsulated cells within liquified systems. However, most cells used in TE are anchorage-dependent, requiring a solid substrate to perform main cellular processes. We hypothesized that liquified capsules encapsulating microparticles are a promising attempt. Inspired by the multiphenotypic cellular environment of bone, we combine the concept of liquified capsules with co-cultures of stem and endothelial cells. After implantation, results show that co-cultured capsules without in vitro stimulation were able to form a mineralized tissue in vivo. We believe that the present ready-to-use TE strategy requiring minimum in vitro manipulation will find great applicability in bone tissue engineering. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.
Reentry Capsule for Sample Return from Asteroids in the Planetary Exploration Missions
NASA Astrophysics Data System (ADS)
Inatani, Yoshifumi
2018-04-01
For carrying sample from the bodies of interplanetary space, a wide range of knowledge of reentry technology is needed. HAYABUSA(MUSES-C) was an asteroid explorer returned to the earth after the 7 years of voyage, and its capsule reenters into the Earth’s atmosphere, which was a good example of reentry technology implemented to the flight vehicle. It performed a safe reentry flight and recovery. For the design of the capsule, many considerations were made due to its higher entry velocity and higher aerodynamic heating than those of normal reentry from the low earth orbit. Taking into account the required functions throughout the orbital flight, reentry flight, and descent/recovery phase, the capsule was deigned, tested, manufactured and flight demonstrated finally. The paper presents the concept of the design and qualification approach of the small space capsule of the asteroid sample and return mission. And presented are how the reentry flight was performed and a brief overview of the post flight analysis primarily for these design validation purposes and for the better understanding of the flight results.
NASA Technical Reports Server (NTRS)
Mizukaki, Toshiharu; Borg, Stephen E.; Danehy, Paul M.; Murman, Scott M.
2014-01-01
This paper presents the results of visualization of separated flow around a generic entry capsule that resembles the Apollo Command Module (CM) and the Orion Multi-Purpose Crew Vehicle (MPCV). The model was tested at flow speeds up to Mach 0.4 at a single angle of attack of 28 degrees. For manned spacecraft using capsule-shaped vehicles, certain flight operations such as emergency abort maneuvers soon after launch and flight just prior to parachute deployment during the final stages of entry, the command module may fly at low Mach number. Under these flow conditions, the separated flow generated from the heat-shield surface on both windward and leeward sides of the capsule dominates the wake flow downstream of the capsule. In this paper, flow visualization of the separated flow was conducted using the background-oriented schlieren (BOS) method, which has the capability of visualizing significantly separated wake flows without the particle seeding required by other techniques. Experimental results herein show that BOS has detection capability of density changes on the order of 10(sup-5).
Cheow, Wean Sin; Kiew, Tie Yi; Hadinoto, Kunn
2014-03-15
Chitosan-coated alginate microcapsules containing high-density biofilm Lactobacillus rhamnosus have been previously shown to exhibit higher freeze drying- and thermal-tolerance than their planktonic counterparts. However, their cell release profile remains poor due to the capsules' susceptibility to the gastric environment. Herein the effects of adding locust bean (LB) and xanthan (XT) gums to alginate (AGN) capsules on the stress tolerance and cell release profiles in simulated gastrointestinal fluids are investigated. Compared to the AGN-only capsules, the AGN-LB capsules exhibit improved stress tolerance (i.e. ≈ 6x for freeze drying, 100x for thermotolerance, 10x for acid), whereas the AGN-XT capsules only improve the acid tolerance. Importantly, the AGN-LB capsules possess the optimal cell release profile with a majority of cells released in the simulated intestinal juice than in the gastric juice. The AGN-LB capsules' superiority is attributed to their stronger interaction with the chitosan coating and high swelling capacity, thus delaying their bulk dissolution. Copyright © 2014 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Hao, Lingyun; Gong, Xinglong; Xuan, Shouhu; Zhang, Hong; Gong, Xiuqing; Jiang, Wanquan; Chen, Zuyao
2006-10-01
SiO 2@CdSe core-shell particles were fabricated by controllable deposition CdSe nanoparticles on silica colloidal spheres. Step-wise coating process was tracked by the TEM and XRD measurements. In addition, SiO 2@CdSe/polypyrrole(PPy) multi-composite particles were synthesized based on the as-prepared SiO 2@CdSe particles by cationic polymerization. The direct electrochemistry of myoglobin (Mb) could be performed by immobilizing Mb on the surface of SiO 2@CdSe particles. Immobilized with Mb, SiO 2@CdSe/PPy-Mb also displayed good bioelectrochemical activity. It confirmed the good biocompatible property of the materials with protein. CdSe hollow capsules were further obtained as the removal of the cores of SiO 2@CdSe spheres. Hollow and porous character of CdSe sub-meter size capsules made them becoming hopeful candidates as drug carriers. Doxorubicin, a typical an antineoplastic drug, was introduced into the capsules. A good sustained drug release behavior of the loading capsules was discovered via performing a release test in the PBS buffer (pH 7.4) solution at 310 k. Furthermore, SiO 2@CdSe/PPy could be converted to various smart hollow capsules via selectively removal of their relevant components.
Comparative study of antibiotic-containing polymethylmetacrylate capsules and beads.
Borzsei, László; Mintál, Tibor; Horváth, Aranka; Koós, Zoltán; Kocsis, Béla; Nyárády, József
2006-01-01
This study aimed at making local antibiotic therapy wider in cases of chronic suppurations by administering antibiotics which previously could not be given in this way through the conventional polymethylmetacrylate (PMMA) carrier techniques. Capsules from this material were produced with a pressing machine designed and laid out by us. The characteristics of antibiotic penetration from this novel carrier were compared to those of PMMA beads. The time-dependent outflow of amikacin, clindamycin, pefloxacin, piperacillin + tazobactam, amoxicillin + clavulanic acid and cefotaxime was examined from the capsules and the beads with standard microbiological techniques using the Micrococcus luteus ATCC9341 test strain. The diameter of the inhibitory zones was measured after 24 h incubation at 37 degrees C and converted to mug/ml antibiotic concentrations. Our results revealed that all antibiotics showed longer-lasting and higher concentration outflow from the PMMA capsules than from the beads. Therefore, these capsules can provide a more promising new opportunity for specific local antimicrobial treatment in cases of chronic suppurative bone and soft tissue injuries. In these cases the polymerization has already been completed and the heat does not influence the structure of the antibiotics; therefore, it can be inserted into the capsules in powder or solution form. Copyright 2006 S. Karger AG, Basel.
Effect of small bowel preparation with simethicone on capsule endoscopy.
Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling
2009-01-01
Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed.
Effect of small bowel preparation with simethicone on capsule endoscopy*
Fang, You-hong; Chen, Chun-xiao; Zhang, Bing-ling
2009-01-01
Background: Capsule endoscopy is a novel non-invasive method for visualization of the entire small bowel. The diagnostic yield of capsule endoscopy depends on the quality of visualization of the small bowel mucosa and its complete passage through the small bowel. To date, there is no standardized protocol for bowel preparation before capsule endoscopy. The addition of simethicone in the bowel preparation for the purpose of reducing air bubbles in the intestinal lumen had only been studied by a few investigators. Methods: Sixty-four participants were randomly divided into two groups to receive a bowel preparation of polyethylene glycol (PEG) solution (Group 1) and both PEG solution and simethicone (Group 2). The PEG solution and simethicone were taken the night before and 20 min prior to capsule endoscopy, respectively. Frames taken in the small intestine were examined and scored for luminal bubbles by two professional capsule endoscopists. Gastric emptying time and small bowel transit time were also recorded. Results: Simethicone significantly reduced luminal bubbles both in the proximal and distal small intestines. The mean time proportions with slight bubbles in the proximal and distal intestines in Group 2 were 97.1% and 99.0%, respectively, compared with 67.2% (P<0.001) and 68.8% (P<0.001) in Group 1. Simethicone had no effect on mean gastric emptying time, 32.08 min in Group 2 compared with 30.88 min in Group 1 (P=0.868), but it did increase mean small intestinal transit time from 227.28 to 281.84 min (P=0.003). Conclusion: Bowel preparation with both PEG and simethicone significantly reduced bubbles in the intestinal lumen and improved the visualization of the small bowel by capsule endoscopy without any side effects observed. PMID:19198022
Development of three-layered rumen escapable capsules for cattle
SEYAMA, Tomohiro; HIRAYASU, Hirofumi; YAMAWAKI, Kenji; ADACHI, Takuhiko; SUGIMOTO, Takayuki; KASAI, Koji
2016-01-01
A new rumen escapable tool is presented for cattle in prospect of developing medical treatment or supplementing trace elements for disease prevention. This tool consists of a three-layered capsule that dissolves in the lower digestive tract, but not in the rumen. The capsule was manufactured by capsule-forming techniques through the use of liquid surface tension. This method does not involve high-temperature treatment, so the capsule can contain not only lipophilic substances but also hydrophilic or heat-sensitive substances. Furthermore, the capsule has a specific gravity of 1.3 and diameter of 6.0 mm, which were previously shown to be appropriate to avoid rumination. The objective of this study was to confirm the effectiveness of the capsule pertinent to rumen escaping. In order to validate rumen escape, capsules containing 30 g of water-soluble vitamin (thiamine hydrochloride) per head were administered to four lactating cows assigned in a crossover trial. In the group administered encapsulated thiamine hydrochloride, blood thiamine levels increased from 12.4 ± 1.03 ng/ml before administration to 54.8 ± 2.21 ng/ml at 6 hr following administration, whereas the level remained at 13.3 ± 2.05 ng/ml in the control group administered via aqueous solution. This indicates that the three-layered capsules passed through the rumen and dissolved in the lower digestive tract, thus functioning as a rumen escapable tool. PMID:27546371
Imposed magnetic field and hot electron propagation in inertial fusion hohlraums
Strozzi, David J.; Perkins, L. J.; Marinak, M. M.; ...
2015-12-02
The effects of an imposed, axial magnetic fieldmore » $$B_{z0}$$ on hydrodynamics and energetic electrons in inertial confinement fusion indirect-drive hohlraums are studied. We present simulations from the radiation-hydrodynamics code HYDRA of a low-adiabat ignition design for the National Ignition Facility, with and without $$B_{z0}=70~\\text{T}$$. The field’s main hydrodynamic effect is to significantly reduce electron thermal conduction perpendicular to the field. This results in hotter and less dense plasma on the equator between the capsule and hohlraum wall. The inner laser beams experience less inverse bremsstrahlung absorption before reaching the wall. The X-ray drive is thus stronger from the equator with the imposed field. We study superthermal, or ‘hot’, electron dynamics with the particle-in-cell code ZUMA, using plasma conditions from HYDRA. During the early-time laser picket, hot electrons based on two-plasmon decay in the laser entrance hole (Regan et al., Phys. Plasmas, vol. 17(2), 2010, 020703) are guided to the capsule by a 70 T field. Twelve times more energy deposits in the deuterium–tritium fuel. For plasma conditions early in peak laser power, we present mono-energetic test-case studies with ZUMA as well as sources based on inner-beam stimulated Raman scattering. Furthermore, the effect of the field on deuterium–tritium deposition depends strongly on the source location, namely whether hot electrons are generated on field lines that connect to the capsule.« less
Idiopathic autoimmune hemolytic anemia due to lecithin overdose: a case report
2009-01-01
Introduction Idiopathic Autoimmune Hemolytic Anemia is a potentially fatal condition which requires prompt and potent treatment. Diagnosis of idiopathic autoimmune hemolytic anemia requires both serologic evidence of autoantibody presence and hemolysis. Although most of the times it is considered idiopathic, several underlying causes have been identified, like autoimmune and connective tissue diseases, viral infections, drugs or hyper function of the immune system. To our knowledge, this is the first case in the international literature describing lecithin-induced autoimmune hemolytic anemia. Case Presentation This case report is to highlight a rare but dangerous adverse reaction to overdose of lecithin. A 38 year old white female from Greece, presented to our emergency room with progressive fatigue over a period of ten days and icteric discoloration of her skin and conjunctiva. The patient had been taking lecithin supplements (1200 mg, 3 capsules a day) over a period of ten days for weight loss. She reports that the last 3 days, prior to the examination, she took 5 capsules/day, so that the supplement would take effect more rapidly. Her past medical, social and family history showed no disturbance. Relatives of the patient were requested to submit any blood-tests taken over a period of 20 days prior to the onset of symptoms caused by Lecithin. All tests proved that all functions were within normal scale. Her physical examination revealed pallor and jaundice without palpable hepatosplenomegaly. Blood biochemistry tests showed total bilirubin 7.5 mg/dl, with indirect bilirubin 6.4 mg/dl and complete blood count showed hemoglobin 7.6 g/dl with blood levels 21.4%. Conclusion In every case of idiopathic autoimmune hemolytic anemia the administration of pharmaceutical substances should always be examined, except for the standard reasons that cause it. In this case the cause of hemolysis was attributed to the excessive intake of lecithin capsules for the loss of body weight. It is important that clinicians and immunologists are aware of this adverse effect. PMID:19178694
Effects of sibutramine alone and with alcohol on cognitive function in healthy volunteers
Wesnes, K A; Garratt, C; Wickens, M; Gudgeon, A; Oliver, S
2000-01-01
Aims To investigate the effects of sibutramine in combination with alcohol in a double-blind, randomised, placebo-controlled, four-way crossover study in 20 healthy volunteers. Methods On each study day each volunteer received either: sibutramine 20 mg+0.5 g kg−1 alcohol; sibutramine 20 mg+placebo alcohol; placebo capsules+0.5 g kg−1 alcohol; or placebo capsules+placebo alcohol. Alcohol was administered 2 h following ingestion of the study capsules. During each study day, assessments of cognitive performance were made prior to dosing, and at 3, 4.5, 6 and 10 h post dosing. Blood alcohol concentration was estimated using a breath alcometer immediately prior to each cognitive performance test session. Each study day was followed by a minimum 7 day washout period. Results Alcohol was found to produce statistically significant impairments in tests of attention (maximum impairment to speed of digit vigilance=49 ms) and episodic memory (maximum impairment to speed of word recognition=74 ms). Alcohol also increased body sway (maximum increase 17.4 units) and lowered self rated alertness (maximum decrease 13.6 mm). These effects were produced by an inferred blood alcohol level of 53.2 mg dl−1.Sibutramine was not found to potentiate any of the effects of alcohol. There was a small, yet statistically significant, interaction effect observed on the sensitivity index of the picture recognition task. In this test, the combined effects of sibutramine and alcohol were smaller than the impairments produced by alcohol alone. Sibutramine, when dosed alone, was associated with improved performance on several tasks. Sibutramine improved attention (mean speed of digit vigilance improved by 21 ms), picture recognition speed (improvement at 3=81) and motor control (tracking error at 3 h reduced by 1.58 mm). Also sibutramine improved postural stability (reducing body sway at 3 h by 14.2 units). Adverse events reported were unremarkable and consistent with the known pharmacology of sibutramine and alcohol. Conclusions There was little evidence of a clinically relevant interaction of sibutramine with the impairment of cognitive function produced by alcohol in healthy volunteers. The single statistically significant interaction indicated a reduction, rather than a worsening, of alcohol-induced impairment when sibutramine is taken concomitantly. Sibutramine when administered alone is associated with improved performance on several tasks. PMID:10671904
Composite Structures Materials Testing for the Orion Crew Vehicle Heat Shield
NASA Technical Reports Server (NTRS)
Khemani, Farah N.
2011-01-01
As research is being performed for the new heat shield for the Orion capsule, National Aeronautics and Space Administration (NASA) is developing the first composite heat shield. As an intern of the Structures Branch in the Engineering Directorate (ES 2), my main task was to set up a test plan to determine the material properties of the honeycomb that will be used on the Orion Crew Module heat shield to verify that the composite is suitable for the capsule. Before conducting composite shell tests, which are performed to simulate the crush performance of the heat shield on the capsule, it is necessary to determine the compression and shear properties of the composite used on the shell. During this internship, I was responsible for developing a test plan, designing parts for the test fixtures as well as getting them fabricated for the honeycomb shear and compression testing. This involved work in Pro/Engineer as well as coordinating with Fab Express, the Building 9 Composite Shop and the Structures Test Laboratory (STL). The research and work executed for this project will be used for composite sandwich panel testing in the future as well. As a part of the Structures Branch, my main focus was to research composite structures. This involves system engineering and integration (SE&I) integration, manufacturing, and preliminary testing. The procedures for these projects that were executed during this internship included design work, conducting tests and performing analysis.
Contraindications for video capsule endoscopy
Bandorski, Dirk; Kurniawan, Niehls; Baltes, Peter; Hoeltgen, Reinhard; Hecker, Matthias; Stunder, Dominik; Keuchel, Martin
2016-01-01
Video capsule endoscopy (VCE) has been applied in the last 15 years in an increasing field of applications. Although many contraindications have been put into perspective, some precautions still have to be considered. Known stenosis of the gastrointestinal tract is a clear contraindication for VCE unless surgery is already scheduled or at least has been considered as an optional treatment modality. In patients with a higher incidence of stenosis, as in an established diagnosis of Crohn’s disease, clinical signs of obstruction, prior radiation or surgical small bowel resection, a preceding test with the self-dissolving patency capsule can override this contraindication. Endoscopic placement of the capsule should be considered in patients with swallowing disorders to avoid aspiration. Esophageal or gastric motility disorders may require endoscopic capsule transport or application of prokinetics if the real-time viewer proofs delayed transit. In pregnant women, VCE should be restricted to urgent cases where diagnosis cannot be postponed after delivery, as data on safety are missing. There is theoretical and clinical evidence that patients with implanted cardiac devices such as a pacemaker, cardioverters or left heart assist devices, can safely undergo VCE in spite of still existing contraindication by manufacturers. Children from the age of 2 years have safely undergone VCE. Although video capsules are not proven safe with magnetic resonance imaging (MRI), first single cases of patients incidentally undergoing MRI with an incorporated capsule have been reported, showing susceptibility artifacts but no signs of clinical harm. PMID:28018097
Mercury Capsule Construction at the NASA Lewis Research Center
1959-08-21
A NASA mechanic secures the afterbody to a Mercury capsule in the hangar at the Lewis Research Center. The capsule was one of two built at Lewis for the “Big Joe” launches scheduled for September 1959. The initial phase of Project Mercury consisted of a series of unmanned launches using the Air Force’s Redstone and Atlas boosters and the Langley-designed Little Joe boosters. The first Atlas launch, referred to as “Big Joe”, was a single attempt early in Project Mercury to use a full-scale Atlas booster to simulate the reentry of a mock-up Mercury capsule without actually placing it in orbit. The overall design of Big Joe had been completed by December 1958, and soon thereafter project manager Aleck Bond assigned NASA Lewis the task of designing the electronic instrumentation and automatic stabilization system. Lewis also constructed the capsule’s lower section, which contained a pressurized area with the electronics and two nitrogen tanks for the retrorockets. Lewis technicians were responsible for assembling the entire capsule: the General Electric heatshield, NASA Langley afterbody and recovery canister, and Lewis electronics and control systems. On June 9, 1959, the capsule was loaded on an air force transport aircraft and flown to Cape Canaveral. A team of 45 test operations personnel from Lewis followed the capsule to Florida and spent the ensuing months preparing it for launch. The launch took place in the early morning hours of September 9, 1959.
Versatile Loading of Diverse Cargo into Functional Polymer Capsules.
Richardson, Joseph J; Maina, James W; Ejima, Hirotaka; Hu, Ming; Guo, Junling; Choy, Mei Y; Gunawan, Sylvia T; Lybaert, Lien; Hagemeyer, Christoph E; De Geest, Bruno G; Caruso, Frank
2015-02-01
Polymer microcapsules are of particular interest for applications including self-healing coatings, catalysis, bioreactions, sensing, and drug delivery. The primary way that polymer capsules can exhibit functionality relevant to these diverse fields is through the incorporation of functional cargo in the capsule cavity or wall. Diverse functional and therapeutic cargo can be loaded into polymer capsules with ease using polymer-stabilized calcium carbonate (CaCO 3 ) particles. A variety of examples are demonstrated, including 15 types of cargo, yielding a toolbox with effectively 500+ variations. This process uses no harsh reagents and can take less than 30 min to prepare, load, coat, and form the hollow capsules. For these reasons, it is expected that the technique will play a crucial role across scientific studies in numerous fields.
Positron radiography of ignition-relevant ICF capsules
Williams, G. J.; Chen, Hui; Field, J. E.; ...
2017-12-11
Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less
Positron radiography of ignition-relevant ICF capsules
DOE Office of Scientific and Technical Information (OSTI.GOV)
Williams, G. J.; Chen, Hui; Field, J. E.
Laser-generated positrons are evaluated as a probe source to radiograph in-flight ignition-relevant inertial confinement fusion capsules. Current ultraintense laser facilities are capable of producing 2 ×10 12 relativistic positrons in a narrow energy bandwidth and short time duration. Monte Carlo simulations suggest that the unique characteristics of such positrons allow for the reconstruction of both capsule shell radius and areal density between 0.002 and 2g/cm 2. The energy-downshifted positron spectrum and angular scattering of the source particles are sufficient to constrain the conditions of the capsule between preshot and stagnation. Here, we evaluate the effects of magnetic fields near themore » capsule surface using analytic estimates where it is shown that this diagnostic can tolerate line integrated field strengths of 100 T mm.« less
Yoshida, Takatsune; Kurimoto, Ippei; Yoshihara, Keiichi; Umejima, Hiroyuki; Ito, Naoki; Watanabe, Shunsuke; Sako, Kazuhiro; Kikuchi, Akihiko
2013-11-01
This study aimed to investigate in vivo absorption of tacrolimus formulated as a solid dispersion using Eudragit E®/HCl (E-SD). E-SD is an aminoalkyl methacrylate copolymer that can be dissolved under neutral pH conditions. E-SD was used alone as a solid dispersion carrier and/or was mixed with tacrolimus primarily dispersed with hydroxypropylmethylcellulose (HPMC). Tacrolimus was formulated with E-SD at several different ratios. Formulations with tacrolimus/E-SD ratio of 1/3 showed higher in vivo absorption, compared to tacrolimus dispersed in the excipients (primarily HPMC) found in commercially available tacrolimus capsules, using a rat in situ closed loop method. Good correlation was observed between in vitro drug solubility and in vivo drug absorption. In vitro solubility tests and rat oral absorption studies of tacrolimus/HPMC solid dispersion formulations were also conducted after mixing the HPMC dispersion with several ratios of E-SD. E-SD/tacrolimus/HPMC formulations yielded high in vitro drug solubility but comparatively low in vivo absorption. Dog oral absorption studies were conducted using capsules containing a formulation of tacrolimus/E-SD at a ratio of 1/5. The E-SD formulation-containing capsule showed higher in vivo drug absorption than tacrolimus dispersed in the standard HPMC capsule. These studies report enhancement of the in vivo absorption of a poorly water-soluble drug following dispersion with E-SD when compared to formulation in HPMC.
MERCURY-ATLAS (MA)-2 - LIFTOFF - CAPE
1961-02-21
S61-01226 (21 Feb. 1961) --- Launch of the unmanned Mercury-Atlas 2 (MA-2) vehicle for a suborbital test flight of the Mercury capsule. The upper part of Atlas is stengthened by an eight-inch wide stainless steel band. The capsule was recovered less than one hour after launch. The altitude was 108 miles. Speed was 13,000 mph. Recovered 1,425 miles downrange. Photo credit: NASA
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
2012-12-05
CAPE CANAVERAL, Fla. – Technicians prepare to fit a special fixture around an Orion capsule inside the high bay of the Operations & Checkout Building at NASA's Kennedy Space Center in Florida. The fixture is designed to enable precise pre-launch processing of the Orion spacecraft. An Orion capsule is being prepared to make a flight test in 2014 on a mission that will not carry any astronauts. Photo by Tim Jacobs
Andam, Cheryl P.; Harris, Simon R.; Cornick, Jennifer E.; Yang, Marie; Bricio-Moreno, Laura; Kamng’ona, Arox W.; French, Neil; Heyderman, Robert S.; Kadioglu, Aras; Everett, Dean B.; Bentley, Stephen D.
2016-01-01
ABSTRACT Streptococcus pneumoniae causes a high burden of invasive pneumococcal disease (IPD) globally, especially in children from resource-poor settings. Like many bacteria, the pneumococcus can import DNA from other strains or even species by transformation and homologous recombination, which has allowed the pneumococcus to evade clinical interventions such as antibiotics and pneumococcal conjugate vaccines (PCVs). Pneumococci are enclosed in a complex polysaccharide capsule that determines the serotype; the capsule varies in size and is associated with properties including carriage prevalence and virulence. We determined and quantified the association between capsule and recombination events using genomic data from a diverse collection of serotypes sampled in Malawi. We determined both the amount of variation introduced by recombination relative to mutation (the relative rate) and how many individual recombination events occur per isolate (the frequency). Using univariate analyses, we found an association between both recombination measures and multiple factors associated with the capsule, including duration and prevalence of carriage. Because many capsular factors are correlated, we used multivariate analysis to correct for collinearity. Capsule size and carriage duration remained positively associated with recombination, although with a reduced P value, and this effect may be mediated through some unassayed additional property associated with larger capsules. This work describes an important impact of serotype on recombination that has been previously overlooked. While the details of how this effect is achieved remain to be determined, it may have important consequences for the serotype-specific response to vaccines and other interventions. PMID:27677790
Geno, K. Aaron; Hauser, Jocelyn R.; Gupta, Kanupriya
2014-01-01
Streptococcus pneumoniae produces a protective capsular polysaccharide whose production must be modulated for bacterial survival within various host niches. Capsule production is affected in part by a phosphoregulatory system comprised of CpsB, CpsC, and CpsD. Here, we found that growth of serotype 2 strain D39 under conditions of increased oxygen availability resulted in decreased capsule levels concurrent with an ∼5-fold increase in Cps2B-mediated phosphatase activity. The change in Cps2B phosphatase activity did not result from alterations in the levels of either the cps2B transcript or the Cps2B protein. Recombinant Cps2B expressed in Escherichia coli similarly exhibited increased phosphatase activity under conditions of high-oxygen growth. S. pneumoniae D39 derivatives with defined deletion or point mutations in cps2B demonstrated reduced phosphatase activity with corresponding increases in levels of Cps2D tyrosine phosphorylation. There was, however, no correlation between these phenotypes and the level of capsule production. During growth under reduced-oxygen conditions, the Cps2B protein was essential for parental levels of capsule, but phosphatase activity alone could be eliminated without an effect on capsule. Under increased-oxygen conditions, deletion of cps2B did not affect capsule levels. These results indicate that neither Cps2B phosphatase activity nor Cps2D phosphorylation levels per se are determinants of capsule levels, whereas the Cps2B protein is important for capsule production during growth under conditions of reduced but not enhanced oxygen availability. Roles for factors outside the capsule locus, possible interactions between capsule regulatory proteins, and links to other cellular processes are also suggested by the results described in this study. PMID:24659769
DOE Office of Scientific and Technical Information (OSTI.GOV)
Saitoh, T.S.; Hoshi, Akira
1997-12-31
Melting and solidification of a phase change material (PCM) in a capsule is of practical importance in latent heat thermal energy storage (LHTES) systems which are considered to be very promising to reduce a peak demand of electricity in the summer season. Two melting modes are involved in melting in capsules. One is close-contact melting between the solid bulk and the capsule wall, and another is natural convection melting in the liquid region. In recent years, close-contact melting processes for a single enclosure have been solved using several numerical methods (e.g., Saitoh and Kato (1994)). However, there is no theoreticalmore » solution considering the inner wall temperature variation within cylindrical or spherical capsules. In this report close-contact melting heat transfer characteristics including melt flow in the liquid film under inner wall temperature distribution were analyzed and simple approximate equations are presented, which facilitates designing of the practical capsule bed LHTES systems. The effects of Stefan number and variable temperature profile etc. were clarified in detail. And the melting velocity of the solid bulk under various conditions was also studied theoretically. In addition, the effects of variable inner wall temperature on molten mass fraction were investigated.« less
Crack Extension and Possibility of Debonding in Encapsulation-Based Self-Healing Materials.
Li, Wenting; Jiang, Zhengwu; Yang, Zhenghong
2017-05-27
The breakage of capsules upon crack propagation is crucial for achieving crack healing in encapsulation-based self-healing materials. A mesomechanical model was developed in this study to simulate the process of crack propagation in a matrix and the potential of debonding. The model used the extended finite element method (XFEM) combined with a cohesive zone model (CZM) in a two-dimensional (2D) configuration. The configuration consisted of an infinite matrix with an embedded crack and a capsule nearby, all subjected to a uniaxial remote tensile load. A parametric study was performed to investigate the effect of geometry, elastic parameters and fracture properties on the fracture response of the system. The results indicated that the effect of the capsule wall on the fracture behavior of the matrix is insignificant for t c / R c ≤ 0.05. The matrix strength influenced the ultimate crack length, while the Young's modulus ratio E c / E m only affected the rate of crack propagation. The potential for capsule breakage or debonding was dependent on the comparative strength between capsule and interface (S c /S int ), provided the crack could reach the capsule. The critical value of S c ,cr /S int,cr was obtained using this model for materials design.
Panic and fear induced by deep brain stimulation.
Shapira, N A; Okun, M S; Wint, D; Foote, K D; Byars, J A; Bowers, D; Springer, U S; Lang, P J; Greenberg, B D; Haber, S N; Goodman, W K
2006-03-01
Mood, cognitive, and behavioural changes have been reported with deep brain stimulation (DBS) in the thalamus, globus pallidus interna, and anterior limb of the internal capsule/nucleus accumbens region. To investigate panic and fear resulting from DBS. Intraoperative DBS in the region of the right and then left anterior limb of the internal capsule and nucleus accumbens region was undertaken to treat a 52 year old man with treatment refractory obsessive-compulsive disorder (OCD). Mood, anxiety, OCD, alertness, heart rate, and subjective feelings were recorded during intraoperative test stimulation and at follow up programming sessions. DBS at the distal (0) contact (cathode 0-, anode 2+, pulse width 210 ms, rate 135 Hz, at 6 volts) elicited a panic attack (only seen at the (0) contact). The patient felt flushed, hot, fearful, and described himself as having a "panic attack." His heart rate increased from 53 to 111. The effect (present with either device) was witnessed immediately after turning the device on, and abruptly ceased in the off condition DBS of the anterior limb of the internal capsule and nucleus accumbens region caused severe "panic." This response may result from activation of limbic and autonomic networks.
On Suggestibility and Placebo: A Follow-Up Study.
Lifshitz, Michael; Sheiner, Eli O; Olson, Jay A; Thériault, Rémi; Raz, Amir
2017-04-01
Identifying what makes some people respond well to placebos remains a major challenge. Here, we attempt to replicate an earlier study in which we found a relationship between hypnotic suggestibility and subjective ratings of relaxation following the ingestion of a placebo sedative (Sheiner, Lifshitz, & Raz, 2016). To assess the reliability of this effect, we tested 34 participants using a similar design. Participants ingested a placebo capsule in one of two conditions: (1) relaxation, wherein we described the capsule as a herbal sedative, or (2) control, wherein we described the capsule as inert. To index placebo response, we collected measures of blood pressure and heart rate, as well as self-report ratings of relaxation and drowsiness. Despite using a similar experimental design as in our earlier study, we were unable to replicate the correlation between hypnotic suggestibility and placebo response. Furthermore, whereas in our former experiment we observed a change in subjective ratings of relaxation but no change in physiological measures, here we found that heart rate dropped in the relaxation condition while subjective ratings remained unchanged. Even within a consistent context of relaxation, therefore, our present results indicate that placebos may induce effects that are fickle, tenuous, and unreliable. Although we had low statistical power, our findings tentatively accord with the notion that placebo response likely involves a complex, multifaceted interaction between traits, expectancies, and contexts.
Isotretinoin Oil-Based Capsule Formulation Optimization
Tsai, Pi-Ju; Huang, Chi-Te; Lee, Chen-Chou; Li, Chi-Lin; Huang, Yaw-Bin; Tsai, Yi-Hung; Wu, Pao-Chu
2013-01-01
The purpose of this study was to develop and optimize an isotretinoin oil-based capsule with specific dissolution pattern. A three-factor-constrained mixture design was used to prepare the systemic model formulations. The independent factors were the components of oil-based capsule including beeswax (X 1), hydrogenated coconut oil (X 2), and soybean oil (X 3). The drug release percentages at 10, 30, 60, and 90 min were selected as responses. The effect of formulation factors including that on responses was inspected by using response surface methodology (RSM). Multiple-response optimization was performed to search for the appropriate formulation with specific release pattern. It was found that the interaction effect of these formulation factors (X 1 X 2, X 1 X 3, and X 2 X 3) showed more potential influence than that of the main factors (X 1, X 2, and X 3). An optimal predicted formulation with Y 10 min, Y 30 min, Y 60 min, and Y 90 min release values of 12.3%, 36.7%, 73.6%, and 92.7% at X 1, X 2, and X 3 of 5.75, 15.37, and 78.88, respectively, was developed. The new formulation was prepared and performed by the dissolution test. The similarity factor f 2 was 54.8, indicating that the dissolution pattern of the new optimized formulation showed equivalence to the predicted profile. PMID:24068886
Impacts of Implosion Asymmetry And Hot Spot Shape On Ignition Capsules
NASA Astrophysics Data System (ADS)
Cheng, Baolian; Kwan, Thomas J. T.; Wang, Yi-Ming; Yi, S. Austin; Batha, Steve
2017-10-01
Implosion symmetry plays a critical role in achieving high areal density and internal energy at stagnation during hot spot formation in ICF capsules. Asymmetry causes hot spot irregularity and stagnation de-synchronization that results in lower temperatures and areal densities of the hot fuel. These degradations significantly affect the alpha heating process in the DT fuel as well as on the thermonuclear performance of the capsules. In this work, we explore the physical factors determining the shape of the hot spot late in the implosion and the effects of shape on Î+/-particle transport. We extend our ignition theory [1-4] to include the hot spot shape and quantify the effects of the implosion asymmetry on both the ignition criterion and capsule performance. We validate our theory with the NIF existing experimental data Our theory shows that the ignition criterion becomes more restrictive with the deformation of the hot spot. Through comparison with the NIF data, we demonstrate that the shape effects on the capsules' performance become more explicit as the self-heating and yield of the capsules increases. The degradation of the thermonuclear burn by the hot spot shape for high yield shots to date can be as high as 20%. Our theory is in good agreement with the NIF data. This work was performed under the auspices of the U.S. Department of Energy by the Los Alamos National Laboratory under Contract No. W-7405-ENG-36.
A wireless narrowband imaging chip for capsule endoscope.
Lan-Rong Dung; Yin-Yi Wu
2010-12-01
This paper presents a dual-mode capsule gastrointestinal endoscope device. An endoscope combined with a narrowband image (NBI), has been shown to be a superior diagnostic tool for early stage tissue neoplasms detection. Nevertheless, a wireless capsule endoscope with the narrowband imaging technology has not been presented in the market up to now. The narrowband image acquisition and power dissipation reduction are the main challenges of NBI capsule endoscope. In this paper, we present the first narrowband imaging capsule endoscope that can assist clinical doctors to effectively diagnose early gastrointestinal cancers, profited from our dedicated dual-mode complementary metal-oxide semiconductor (CMOS) sensor. The dedicated dual-mode CMOS sensor can offer white-light and narrowband images. Implementation results show that the proposed 512 × 512 CMOS sensor consumes only 2 mA at a 3-V power supply. The average current of the NBI capsule with an 8-Mb/s RF transmitter is nearly 7 ~ 8 mA that can continuously work for 6 ~ 8 h with two 1.5-V 80-mAh button batteries while the frame rate is 2 fps. Experimental results on backside mucosa of a human tongue and pig's small intestine showed that the wireless NBI capsule endoscope can significantly improve the image quality, compared with a commercial-of-the-shelf capsule endoscope for gastrointestinal tract diagnosis.
Ghosh, Pranay; Vahedipour, Kaveh; Lin, Min; Vogel, Jens H; Haynes, Charles A; von Lieres, Eric
2013-01-01
The zonal rate model (ZRM) has previously been applied for analyzing the performance of axial flow membrane chromatography capsules by independently determining the impacts of flow and binding related non-idealities on measured breakthrough curves. In the present study, the ZRM is extended to radial flow configurations, which are commonly used at larger scales. The axial flow XT5 capsule and the radial flow XT140 capsule from Pall are rigorously analyzed under binding and non-binding conditions with bovine serum albumin (BSA) as test molecule. The binding data of this molecule is much better reproduced by the spreading model, which hypothesizes different binding orientations, than by the well-known Langmuir model. Moreover, a revised cleaning protocol with NaCl instead of NaOH and minimizing the storage time has been identified as most critical for quantitatively reproducing the measured breakthrough curves. The internal geometry of both capsules is visualized by magnetic resonance imaging (MRI). The flow in the external hold-up volumes of the XT140 capsule was found to be more homogeneous as in the previously studied XT5 capsule. An attempt for model-based scale-up was apparently impeded by irregular pleat structures in the used XT140 capsule, which might lead to local variations in the linear velocity through the membrane stack. However, the presented approach is universal and can be applied to different capsules. The ZRM is shown to potentially help save valuable material and time, as the experiments required for model calibration are much cheaper than the predicted large-scale experiment at binding conditions. Biotechnol. Bioeng. 2013; 110: 1129–1141. © 2012 Wiley Periodicals, Inc. PMID:23097218
Aero-thermo-dynamic analysis of a low ballistic coefficient deployable capsule in Earth re-entry
NASA Astrophysics Data System (ADS)
Zuppardi, G.; Savino, R.; Mongelluzzo, G.
2016-10-01
The paper deals with a microsatellite and the related deployable recovery capsule. The aero-brake is folded at launch and deployed in space and is able to perform a de-orbiting controlled re-entry. This kind of capsule, with a flexible, high temperature resistant fabric, thanks to its lightness and modulating capability, can be an alternative to the current ;conventional; recovery capsules. The present authors already analyzed the trajectory and the aerodynamic behavior of low ballistic coefficient capsules during Earth re-entry and Mars entry. In previous studies, aerodynamic longitudinal stability analysis and evaluation of thermal and aerodynamic loads for a possible suborbital re-entry demonstrator were carried out in both continuum and rarefied regimes. The present study is aimed at providing preliminary information about thermal and aerodynamic loads and longitudinal stability for a similar deployable capsule, as well as information about the electronic composition of the plasma sheet and its possible influence on radio communications at the altitudes where GPS black-out could occur. Since the computer tests were carried out at high altitudes, therefore in rarefied flow fields, use of Direct Simulation Monte Carlo codes was mandatory. The computations involved both global aerodynamic quantities (drag and longitudinal moment coefficients) and local aerodynamic quantities (heat flux and pressure distributions along the capsule surface). The results verified that the capsule at high altitude (150 km) is self-stabilizing; it is stable around the nominal attitude or at zero angle of attack and unstable around the reverse attitude or at 180° angle of attack. The analysis also pointed out the presence of extra statically stable equilibrium trim points.
Capsule endoscopy: Current practice and future directions
Hale, Melissa F; Sidhu, Reena; McAlindon, Mark E
2014-01-01
Capsule endoscopy (CE) has transformed investigation of the small bowel providing a non-invasive, well tolerated means of accurately visualising the distal duodenum, jejunum and ileum. Since the introduction of small bowel CE thirteen years ago a high volume of literature on indications, diagnostic yields and safety profile has been presented. Inclusion in national and international guidelines has placed small bowel capsule endoscopy at the forefront of investigation into suspected diseases of the small bowel. Most commonly, small bowel CE is used in patients with suspected bleeding or to identify evidence of active Crohn’s disease (CD) (in patients with or without a prior history of CD). Typically, CE is undertaken after upper and lower gastrointestinal flexible endoscopy has failed to identify a diagnosis. Small bowel radiology or a patency capsule test should be considered prior to CE in those at high risk of strictures (such as patients known to have CD or presenting with obstructive symptoms) to reduce the risk of capsule retention. CE also has a role in patients with coeliac disease, suspected small bowel tumours and other small bowel disorders. Since the advent of small bowel CE, dedicated oesophageal and colon capsule endoscopes have expanded the fields of application to include the investigation of upper and lower gastrointestinal disorders. Oesophageal CE may be used to diagnose oesophagitis, Barrett’s oesophagus and varices but reliability in identifying gastroduodenal pathology is unknown and it does not have biopsy capability. Colon CE provides an alternative to conventional colonoscopy for symptomatic patients, while a possible role in colorectal cancer screening is a fascinating prospect. Current research is already addressing the possibility of controlling capsule movement and developing capsules which allow tissue sampling and the administration of therapy. PMID:24976712
DOE Office of Scientific and Technical Information (OSTI.GOV)
Séguin, F. H.; Li, C. K.; DeCiantis, J. L.
Three orthogonal proton emission imaging cameras were used to study the 3D effects of low-mode drive asymmetries and target asymmetries on nuclear burn symmetry and yield in direct-drive, inertial-confinement-fusion experiments. The fusion yield decreased quickly as the burn region became asymmetric due to either drive or capsule asymmetry. Measurements and analytic scaling are used to predict how intentionally asymmetric capsule shells could improve performance by compensating for drive asymmetry when it cannot be avoided (such as with indirect drive or with polar direct drive).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Seguin, F. H.; Li, C. K.; DeCiantis, J. L.
Three orthogonal proton emission imaging cameras were used to study the 3D effects of low-mode drive asymmetries and target asymmetries on nuclear burn symmetry and yield in direct-drive, inertial-confinement-fusion experiments. The fusion yield decreased quickly as the burn region became asymmetric due to either drive or capsule asymmetry. Furthermore, measurements and analytic scaling are used to predict how intentionally asymmetric capsule shells could improve performance by compensating for drive asymmetry when it cannot be avoided (such as with indirect drive or with polar direct drive).
Seguin, F. H.; Li, C. K.; DeCiantis, J. L.; ...
2016-03-22
Three orthogonal proton emission imaging cameras were used to study the 3D effects of low-mode drive asymmetries and target asymmetries on nuclear burn symmetry and yield in direct-drive, inertial-confinement-fusion experiments. The fusion yield decreased quickly as the burn region became asymmetric due to either drive or capsule asymmetry. Furthermore, measurements and analytic scaling are used to predict how intentionally asymmetric capsule shells could improve performance by compensating for drive asymmetry when it cannot be avoided (such as with indirect drive or with polar direct drive).
A novel flexible microfluidic meshwork to reduce fibrosis in glaucoma surgery.
Amoozgar, Behzad; Wei, Xiaoling; Hui Lee, Jun; Bloomer, Michele; Zhao, Zhengtuo; Coh, Paul; He, Fei; Luan, Lan; Xie, Chong; Han, Ying
2017-01-01
Fibrosis and hence capsule formation around the glaucoma implants are the main reasons for glaucoma implant failure. To address these issues, we designed a microfluidic meshwork and tested its biocompatibility in a rabbit eye model. The amount of fibrosis elicited by the microfluidic meshwork was compared to the amount elicited by the plate of conventional glaucoma drainage device. Six eyes from 3 New Zealand albino rabbits were randomized to receive either the novel microfluidic meshwork or a plate of Ahmed glaucoma valve model PF7 (AGV PF7). The flexible microfluidic implant was made from negative photoresist SU-8 by using micro-fabrication techniques. The overall size of the meshwork was 7 mm × 7 mm with a grid period of 100 μm. Both implants were placed in the subtenon space at the supratemporal quadrant in a standard fashion. There was no communication between the implants and the anterior chamber via a tube. All animal eyes were examined for signs of infection and implant erosion on days 1, 3, 7, and 14 and then monthly. Exenterations were performed in which the entire orbital contents were removed at 3 months. Histology slides of the implant and the surrounding tissues were prepared and stained with hematoxylin-eosin. Thickness of the fibrous capsules beneath the implants were measured and compared with paired student's t-test between the two groups. The gross histological sections showed that nearly no capsule formed around the microfluidic meshwork in contrast to the thick capsule formed around the plate of AGV PF7. Thickness of the fibrotic capsules beneath the AGV PF7 plate from the 3 rabbit eyes was 90μm, 82μm, and 95 μm, respectively. The thickness at the bottom of fibrotic capsules around the new microfluidic implant were 1μm, 2μm, and 1μm, respectively. The difference in thickness of capsule between the two groups was significant (P = 0.002). No complications were noticed in the 6 eyes, and both implants were tolerated well by all rabbits. The microfluidic meshwork elicited minimal fibrosis and capsule formation after 3-months implantation in a rabbit model. This provides promising evidence to aid in future development of a new glaucoma drainage implant that will elicit minimal scar formation and provide better long-term surgical outcomes.
Feasibility of a colon capsule overnight procedure followed by colonoscopy.
Brechmann, T; Schmiegel, W; Klute, L; Rösch, T; Pox, C
2016-02-01
Due to limited acceptance of colonoscopy as diagnostic and screening test alternatives are warranted. Colon capsule endoscopy (CCE) has been shown to be a possible filter test, but because of logistical issues a second bowel preparation is usually required, if consecutive colonoscopy is needed. We therefore evaluated the feasibility of a single bowel preparation for both overnight CCE and (therapeutical) colonoscopy thereafter. Patients from two university hospitals referred to undergo colonoscopy were prospectively included in a dual centre feasibility study. A polyethylene glycol (PEG) based bowel preparation-schedule with ingestion of a colon capsule endoscopy (CCE) at 10pm and subsequent colonoscopy at about 12am on the next day was investigated. The first generation PillCam colon capsule was used with 4 different preparation protocols containing several prokinetics in different compositions (i. e. metoclopramide, erythromycin, sennosoides). The main endpoint was the proportion of patients who completed both CCE and colonoscopy; secondary endpoints were capsule transit times, amount of colon seen on CCE, bowel cleanliness, sensitivity and specifity of CCE and patients' acceptance. 50 patients between 18 and 75 years were included. The sequence of overnight colon capsule endoscopy and colonoscopy was successfully completed in all but one (one refused colonoscopy). The capsule was excreted during recording time in 86 % of examinations, visualization of the complete colon was possible in 60 %, but adequate colon preparation was achieved in only 45 % irrespective of the regimen used. The preparation regimen consisting of a PEG-solution, erythromycin as prokinetic drug followed by PEG-solution as boost showed the largest proportion of adequate preparations. Overall sensitivity and specificity of CCE for polyps of any size were 65 % and 76 %, respectively. 26 of 30 patients (86.7 %) returned the subjective assessment questionnaire. 23 patients (88 %) reported mild to no discomfort or embarrassment during CCE, whereas 15 patients (58 %) did during the preparation procedure. Drinking the purgative solution was the most inconvenient step in 84 % of cases, drinking the boosts during CCE the second inconvenient step (60 %). Overnight CCE-procedure followed by direct capsule-reading is feasible and safe and might avoid repetitive bowel preparation for subsequent colonoscopy. The bowel preparation needs to be improved. © Georg Thieme Verlag KG Stuttgart · New York.
A Passive Earth-Entry Capsule for Mars Sample Return
NASA Technical Reports Server (NTRS)
Mitcheltree, Robert A.; Kellas, Sotiris
1999-01-01
A combination of aerodynamic analysis and testing, aerothermodynamic analysis, structural analysis and testing, impact analysis and testing, thermal analysis, ground characterization tests, configuration packaging, and trajectory simulation are employed to determine the feasibility of an entirely passive Earth entry capsule for the Mars Sample Return mission. The design circumvents the potential failure modes of a parachute terminal descent system by replacing that system with passive energy absorbing material to cushion the Mars samples during ground impact. The suggested design utilizes a spherically blunted 45-degree half-angle cone forebody with an ablative heat shield. The primary structure is a hemispherical, composite sandwich enclosing carbon foam energy absorbing material. Though no demonstration test of the entire system is included, results of the tests and analysis presented indicate that the design is a viable option for the Mars Sample Return Mission.
Hosokawa, Akihiro; Kato, Yoshiteru
2012-03-01
The purpose of this study was to examine application of ultraviolet (UV) laser irradiation to printing soft gelatin capsules containing titanium dioxide (TiO(2)) in the shells and to study effect of UV laser power on the color strength of printing on the soft gelatin capsules. Size 6 Oval type soft gelatin capsules of which shells contained 0.685% TiO(2) and 0.005% ferric dioxide were used in this study. The capsules were irradiated pulsed UV laser at a wavelength 355 nm. The color strength of the printed capsules was determined by a spectrophotometer as total color difference (dE). The soft gelatin capsules which contained TiO(2) in the shells could be printed gray by the laser. Many black particles, which were associated with the printing, were formed at the colored parts of the shells. It was found that there were two inflection points in relationship between output laser energy of a pulse and dE. Below the lower point, the capsules were not printed. From the lower point to the upper point, the capsules were printed gray and total color difference of the printing increased linearly in proportion with the output laser energy. Beyond the upper point, total color difference showed saturation because of micro-bubbles formation at the laser irradiated spot. Soft gelatin capsules containing TiO(2) in the shells could be performed stable printing using the UV laser printing technique. Color strength of the printing could be controlled by regulating the laser energy between the two inflection points.
Bass, Lee M; Misiewicz, Lawrence
2012-11-01
Wireless capsule endoscopy (WCE) is an increasingly used procedure for visualization of the small intestine. One challenge in pediatric WCE is the placement of the capsule in a population unable to swallow it for a variety of reasons. Here we present a novel use of the real-time (RT) viewer in the endoscopic deployment of the capsule endoscope. We performed a retrospective chart review on all WCE completed at the Children's Memorial Hospital from February 2010 to May 2011. Following a diagnostic upper endoscopy, the RT viewer was attached to the capsule recorder and image was noted before insertion. The endoscope and AdvanCE capsule delivery device were slowly advanced into duodenum while maintaining visualization on the RT viewer. A total of 17 patients who underwent a WCE with endoscopic placement were identified. They ranged in ages from 2 to 19 years. Thirteen patients required endoscopic placement because of the inability to swallow the capsule, whereas 4 were placed during a scheduled procedure to take advantage of sedation and airway protection. All of the 17 patients had successful deployment of the capsule into the duodenal lumen. In each case, the endoscopist was able to confirm capsule location in duodenum during scope withdrawal. There was no evidence of iatrogenic trauma or bleeding in any patient. There were 5 incomplete studies, a completion rate consistent with that described in the literature. The use of the RT viewer for endoscopic deployment of WCE is an effective technique to improve visualization of capsule placement in the pediatric population.
NASA Technical Reports Server (NTRS)
Potvin, Jean; Ray, Eric
2017-01-01
We describe a new calculation of the opening shock factor C (sub k) characterizing the inflation performance of NASA's Orion spacecraft main and drogue parachutes opening under a reefing constraint (1st stage reefing), as currently tested in the Capsule Parachute Assembly System (CPAS) program. This calculation is based on an application of the Momentum-Impulse Theorem at low mass ratio (R (sub m) is less than 10 (sup -1)) and on an earlier analysis of the opening performance of drogues decelerating point masses and inflating along horizontal trajectories. Herein we extend the reach of the Theorem to include the effects of payload drag and gravitational impulse during near-vertical motion - both important pre-requisites for CPAS parachute analysis. The result is a family of C (sub k) versus R (sub m) curves which can be used for extrapolating beyond the drop-tested envelope. The paper proves this claim in the case of the CPAS Mains and Drogues opening while trailing either a Parachute Compartment Drop Test Vehicle or a Parachute Test Vehicle (an Orion capsule boiler plate). It is seen that in all cases the values of the opening shock factor can be extrapolated over a range in mass ratio that is at least twice that of the test drop data.
Design Options for the High-Foot Ignition Capsule Series on NIF
NASA Astrophysics Data System (ADS)
Dittrich, T. R.; Hurricane, O. A.; Berzak Hopkins, L. F.; Callahan, D. A.; Clark, D.; Doeppner, T.; Haan, S. W.; Hammel, B. A.; Harte, J. A.; Hinkel, D. E.; Ma, T.; Pak, A. E.; Park, H.-S.; Salmonson, J. D.; Weber, C. R.; Zimmerman, G. B.; Olson, R. E.; Kline, J. L.; Leeper, R. J.
2015-11-01
Several options exist for improving implosion performance in the High-Foot series of ignition capsules on NIF. One option is to modify the fill tube used to supply DT to the capsule. Simulations indicate that a gold-coated glass tube may reduce implosion hydro effects and allow fielding a larger diameter tube capable of supporting the capsule, eliminating the need for the nominal tent support. A second option adds a fourth shock to the implosion history. According to simulation, this extra shock improves fuel confinement and capsule performance. A third option studies the feasibility of holding the DT fuel in liquid form in a foam layer inside the shell. This ``wetted foam'' concept, advanced by Olson, has existed for several years and may allow some control over the convergence of the capsule during implosion. This work was performed under the auspices of the Department of Energy by Lawrence Livermore National Laboratory under contract DE-AC52-07NA27344.
Moghimipour, Eskandar; Rezaei, Mohsen; Kouchak, Maryam; Fatahiasl, Jafar; Angali, Kambiz Ahmadi; Ramezani, Zahra; Amini, Mohsen; Dorkoosh, Farid Abedin; Handali, Somayeh
2018-05-01
The aim of the present research was to evaluate the impact of coating layers on release profile from enteric coated dosage forms. Capsules were coated with Eudragit FS 30D using dipping method. The drug profile was evaluated in both phosphate buffer and Hank's solutions. Utilization X-ray imaging, gastrointestinal transmission of enteric coated capsules was traced in rats. According to the results, no release of the drug was found at pH 1.2, and the extent of release drug in pH 6.8 medium was decreased by adding the coating layers. The results indicated single-layer coated capsules in phosphate buffer were significantly higher than that in Hank's solution. However, no significant difference was observed from capsules with three coating layers in two different dissolution media. X-ray imaging showed that enteric coated capsules were intact in the stomach and in the small intestine, while disintegrated in the colon.
Kampen, Annette H; Tollersrud, Tore; Lund, Arve
2005-03-01
Isogenic variants of Staphylococcus aureus strain Reynolds expressing either no capsule or capsular polysaccharide (CP) type 5 (CP5) or type 8 (CP8) were used to assess the effect of CP on bacterial killing and the respiratory burst of bovine neutrophils. The effects of antisera specific for CP5 and CP8 were also evaluated. The killing of live bacteria by isolated neutrophils was quantified in a bactericidal assay, while the respiratory burst after stimulation with live bacteria in whole blood was measured by flow cytometry. The expression of a CP5 or CP8 capsule protected the bacteria from being killed by bovine neutrophils in vitro (P <0.001), and the capsule-expressing variants did not stimulate respiratory burst activity in calf whole blood. The addition of serotype-specific antisera increased the killing of the capsule-expressing bacteria and enhanced their stimulating effect in the respiratory burst assay (P <0.01). When the S. aureus variants were grown under conditions known not to promote capsule expression, there were no significant differences between them. The present study demonstrates that the expression of S. aureus CP5 or CP8 confers resistance to opsonophagocytic killing and prevents the bacteria from inducing respiratory burst of bovine neutrophils in vitro and that these effects can be reversed by the addition of serotype-specific antisera.
Nikolakakis, I; Aragon, O B; Malamataris, S
1998-07-01
The purpose of this study was to compare some indicators of capsule-filling performance, as measured by tapped density under different conditions, and elucidate possible quantitative relationships between variation of capsule fill-weight (%CV) and gravitational and inter-particle forces (attractive or frictional) derived from measurements of particle size, true density, low compression and tensile strength. Five common pharmaceutical diluents (lactose, maize starch, talc, Emcocel and Avicel) were investigated and two capsule-filling methods (pouring powder and dosator nozzle) were employed. It was found that for the pouring-type method the appropriateness of Hausner's ratio (HR), Carr's compressibility index (CC%) and Kawakita's constant (alpha) as indicators of capsule fill-weight variation decreases in the order alpha > CC% > HR; the appropriateness of these indicators also decreases with increasing cylinder size and with impact velocity during tapping. For the dosator-type method the appropriateness of the indicators decreases in the order HR > CC% > alpha, the opposite of that for the pouring-type method; the appropriateness of the indicators increases with decreasing cylinder size and impact velocity. The relationship between %CV and the ratio of inter-particle attractive to gravitational forces calculated from measurements of particle size and true density (Fvdw/Wp) was more significant for the pouring-type capsule-filling method. For the dosator-type method a significant relationship (1% level) was found between %CV and the product of Fvdw/Wp and a function expressing the increase, with packing density (p(f)), in the ratio of frictional to attractive inter-particle forces derived from compression (P) and tensile-strength (T) testing, d(log(P/T))/d(p(f)). The value of tapped density in predictions of capsule-filling performance is affected by the testing conditions in a manner depending on the filling method applied. For the pouring-type method predictions can be based on the ratio of attractive (inter-particle) to gravitational forces, whereas for the dosator-type method the contribution of frictional and attractive forces should, because of packing density change, also be taken into account.
2012-09-20
CAPE CANAVERAL, Fla. - Astronauts Mike Fossum and Cady Coleman look over a model capsule fit with rotor blades ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-09-20
CAPE CANAVERAL, Fla. - NASA's Johnson Space Center Aerospace Engineer Jeff Hagen attaches a rotor to the top of a model capsule ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
Laser welding of biological tissue: experimental studies in ophthalmology
NASA Astrophysics Data System (ADS)
Pini, Roberto; Rossi, Francesca; Menabuoni, Luca
2006-04-01
In this paper we present an original approach to laser welding of ocular media. Attention is focused on laser welding of the cornea and lens capsule. The process is based on the interaction of near infrared diode laser radiation (at 810 nm) with tissue that was previously stained with an Indocyanine Green solution in sterile water. The topical application of the chromophore makes possible a selective heating of the tissue, which results in a homogenous welding effect with low thermal damage to the surrounding tissue. Experimental tests were performed ex vivo on both capsule and cornea, and in vivo (rabbits) only on the cornea, in order to characterize the process as a whole. Spectrophotometric, biomechanical, and thermal measurements were carried out in order to study the laser-tissue interaction, while morphological, histological and auto-florescence microscopy analyses made during a follow-up study provided information on the healing process in welded rabbit corneas. The welding procedure was set up according to the type of tissue, with the staining procedure and irradiation conditions being optimized in each case. Our test indicated that: 1) laser welding of corneal wounds, which is a non contact technique performed at low continuous wave laser power (12 W/cm2), can be proposed as a support to or substitute for the standard suturing technique in cataract surgery and in penetrating keratoplasty (in corneal transplants); 2) laser welding of the lens capsule requires a "contact irradiating technique" in order to be efficiently performed, since the tissue is in underwater conditions, with single spot pulses of about 100 J/cm2 fluence and pulse duration around 100 ms. In the latter case, laser welding was proposed as a tool for assisting closure of the lens capsule after the lens refilling procedure (Phaco-ersatz), or for repairing capsular breaks induced by accidental traumas or produced intraoperatively.
Sun, Jian-Hui; Huo, Hai-Ru; Li, Xiao-Qin; Li, Hong-Mei; Qin, De-Huai; Wu, Chun
2018-04-01
Huanshao capsule is widely used in irregular menstruation and has achieved a good effect. Huanshao capsule can promote gonad development in mice, significantly improve the ovarian index in mice, increase estrogen level and reduce FSH level in rats, inhibit the pain response induced by oxytocin and estrogen, inhibit writhing reaction induced by acetic acid pain in mice. Due to the complexity of traditional Chinese medical formula, the pharmacological mechanism of the treatment on the irregular menstruation of the Huanshao capsule is unclear. In this study, the internet-based computation platform (www.tcmip.cn)was used to explore the molecular mechanism of Huanshao capsule on the menstrual. The aim of this study was to find the molecular mechanism of Huanshao capsule in treating menstrual. In the study of the molecular mechanism of Huanshao capsule in the treatment of menstrual by using the internet-based computation platform, Huanshao capsule maybe treat the menstrual by the pathway of endocrine system, GnRH signal transduction pathway, estrogen signal transduction pathway, oxytocin signaling pathway, thyroid hormone signaling pathway, VEGF signaling pathway, FCεRI signaling pathway and purine metabolism and nucleotide metabolism. The early pharmacological study confirmed Huanshao capsule could increase the serum estradiol level and decrease follicle stimulating hormone level and the traditional Chinese medicine pharmacology coincide with the prediction result of internet-based computation platform which roles as the pathway of GnRH signaling pathway and estrogen signal transduction pathway. Other pathway needs further experimental verification. Copyright© by the Chinese Pharmaceutical Association.
Effects of yogurt and applesauce on the oral bioavailability of nilotinib in healthy volunteers.
Yin, Ophelia Q P; Rudoltz, Marc; Galetic, Ivana; Filian, Jeiry; Krishna, Arun; Zhou, Wei; Custodio, Joseph; Golor, Georg; Schran, Horst
2011-11-01
Nilotinib, a potent orally bioavailable BCR-ABL tyrosine kinase inhibitor, is currently available as a hard gelatin capsule that must be swallowed whole. For patients who may have difficulty swallowing the intact capsule, an alternative mode of administration is desirable. The authors compared the bioavailability of nilotinib from the following administrations in 48 healthy subjects: (1) 400 mg nilotinib given as two 200-mg nilotinib intact capsules; (2) contents of two 200-mg nilotinib capsules, each capsule dispersed in 1 teaspoon of nonfat plain yogurt; and (3) contents of two 200-mg nilotinib capsules, each capsule dispersed in 1 teaspoon of applesauce. Nilotinib absorption was modestly increased following the administration of nilotinib dispersed in yogurt. The geometric mean ratios (90% confidence intervals) for nilotinib C(max), AUC(0-tlast), and AUC(0-inf) were 1.31 (1.22-1.41), 1.11 (1.05-1.16), and 1.08 (1.02-1.15), respectively. Administration of nilotinib dispersed in applesauce showed equivalent bioavailability compared with administration of nilotinib as intact capsules. The geometric mean ratios (90% confidence intervals) for nilotinib C(max), AUC(0-tlast), and AUC(0-inf) were 0.95 (0.88-1.02), 0.99 (0.94-1.04), and 0.97 (0.90-1.03), respectively. Each treatment was well tolerated in the study subjects. The data support a feasible alternative method of nilotinib administration; each capsule's contents may be dispersed in 1 teaspoon of applesauce and taken immediately.
Cable attachment for a radioactive brachytherapy source capsule
Gross, Ian G; Pierce, Larry A
2006-07-18
In cancer brachytherapy treatment, a small californium-252 neutron source capsule is attached to a guide cable using a modified crimping technique. The guide cable has a solid cylindrical end, and the attachment employs circumferential grooves micromachined in the solid cable end. The attachment was designed and tested, and hardware fabricated for use inside a radioactive hot cell. A welding step typically required in other cable attachments is avoided.
2012-07-24
CAPE CANAVERAL, Fla. – The instrument package and capsule built by Rocket University participants for a high-altitude balloon flight. The test flight was used to evaluate the stability of an instrumented capsule as it fell to Earth before its parachute opened. Rocket University is a program of courses, workshops, labs and projects offered to engineering and research pros of all stripes to keep their skills fresh and broaden their experiences. Photo credit: NASA/Jim Grossmann
2012-07-24
CAPE CANAVERAL, Fla. – Rocket University participants inspect a capsule that is being prepared for a high-altitude balloon flight. The test flight was used to evaluate the stability of an instrumented capsule as it fell to Earth before its parachute opened. Rocket University is a program of courses, workshops, labs and projects offered to engineering and research pros of all stripes to keep their skills fresh and broaden their experiences. Photo credit: NASA/Jim Grossmann
Paek, Laurence S; Giot, Jean-Philippe; Tétreault-Paquin, Jean-Olivier; St-Jacques, Samuel; Nelea, Monica; Danino, M Alain
2015-04-01
In the first stage of expander-to-implant breast reconstruction, postoperative expansion is classically initiated at 10 to 14 days (conventional approach). The authors hypothesized that it may be beneficial to wait 6 weeks postoperatively before initiating serial expansion (delayed approach). Clinical and ultrastructural periprosthetic capsule analysis is first required before determining whether a delayed approach ultimately improves capsular tissue adherence and expansion process predictability. Patients undergoing two-stage implant-based breast reconstruction were enrolled prospectively in this study. During expander-to-implant exchange, the clinical presence of "Velcro" effect, biofilm, and double capsule was noted. Periprosthetic capsule samples were also sent for scanning electron microscopic observation of three parameters: surface relief, cellularity, and biofilm. Samples were divided into four groups for data analysis (group 1, conventional/Biocell; group 2, delayed/Biocell; group 3, conventional/Siltex; and group 4, delayed/Siltex). Fifty-six breast reconstructions were included. Each group comprised between 13 and 15 breasts. In group 1, no cases exhibited the Velcro effect and there was a 53.8 percent incidence of both biofilm and double capsule. In group 2, all cases demonstrated the Velcro effect and there were no incidences of biofilm or double capsule. Group 3 and group 4 cases did not exhibit a Velcro effect or double-capsule formation; however, biofilm was present in up to 20.0 percent. All group 2 samples revealed more pronounced three-dimensional relief on scanning electron microscopy. Variations in expansion protocols can lead to observable modifications in periprosthetic capsular architecture. There may be real benefits to delaying expander inflation until 6 weeks postoperatively with Biocell expanders.
NASA Photographer Prepares to Film a Mercury Capsule
1959-06-21
National Aeronautics and Space Administration (NASA) photographer Arthur Laufman sets up a camera to film a Mercury capsule that was constructed by the Lewis Research Center staff. Lewis engineers and mechanics built two of the capsules for the upcoming Big Joe launches in September 1959. Big Joe was an attempt early in Project Mercury to use a full-scale Atlas booster to simulate the reentry of a mock-up Mercury capsule without actually placing it in orbit. The Photographic Branch, referred to as the Photo Lab, was part of the center’s Technical Reports Division. Originally the group performed normal and high-speed still image and motion picture photography. The photographers documented construction, performed publicity work, created images for reports, photographed data on manometer boards, and recorded test footage. Laufman joined the Photo Lab staff in 1948 and began producing full-length technical films as a tool to educate those outside of the agency on the research being conducted at Lewis. He worked with engineers to determine proper subjects for these films and develop a script. Laufman not only filmed tests, but also supporting footage of facilities, models, and staff members. He then edited the footage and added audio, visuals, and narration. The film masters were assigned standard identification numbers and add to the Photo Lab’s catalogue.
Ohta, Hidetoshi; Katsuki, Shinichi
2014-01-01
Ever since capsule endoscopy (CE) was introduced into clinical practice, we gastroenterologists have been dreaming of using this less invasive modality to explore the entire gastrointestinal (GI) tract. To realize this dream, we have developed a magnetic navigation system which includes real-time internet streaming of endoscopic video and some useful gadgets (position detection by means of magnetic impedance (MI) sensors and a modified capsule that is "weightless" in water). The design of the weightless capsule made it possible with 0.5T (Tesla) extracorporeal magnets to control the capsule beyond 20cm. A pair of MI sensors on the body surface could detect subtle magnetic flux generated by an intra-capsular magnet in the GI tract by utilizing the space diversity effect which eliminated the interference of terrestrial magnetism. Subjects underwent CE, during which they were free from confinement in the hospital, except for 1 hour when the capsule was manipulated in the stomach and colon. This study had a completion rate of 97.5%. The high completion rate indicates that our system (single capsule endoscopy-SCE) with further improvements could become a viable modality for screening of the entire GI tract.
Wang, X; Meng, M Q-H
2010-01-01
Use of the capsule endoscope (CE) in clinical examinations is limited by its passive movement resulting from the natural peristalsis of the gastrointestinal (GI) tract. Therefore, a locomotion mechanism is desirable for the next generation of capsule endoscope. Understanding the resistant properties of the small intestine is essential for designing a wireless magnetic actuation mechanism. In this paper, in vitro experiments were carried out to investigate the resistant force of the small intestine using 15 specially designed capsule prototypes and analysed the effect of the capsule dimension and moving speed. Segments of porcine small intestine were employed as a conservative model for the human intestine. When the capsules under experiment were moving at a speed of 0.5 mm/s, a resistant force of 20 to 100 mN were measured for the capsule diameter in the range of 8 to 13 mm. The force increased with moving speed. The intrinsic cause of the resistant force of the small intestine is discussed based on an analysis of the experimental data. It is believed that the viscoelastic properties of the tissue play an important role in the resistant characteristics of the small intestine.
Meredith, Alicea N; Harper, Bryan; Harper, Stacey L
2016-01-01
Encapsulation technology involves entrapping a chemical active ingredient (a.i.) inside a hollow polymeric shell and has been applied to commercial pesticide manufacturing for years to produce capsule suspension (CS) formulations with average particle sizes in the micron-scale. The few literature sources that investigate the environmental fate and toxicity to non-target organisms of encapsulated commercially available pesticide products with regard to capsule size report on average sizes between 20 and 50 μm. Here, we have identified a CS formulation with an average capsule size of approximately 2 μm with some capsules extending into the nanometer scale (~200 nm). Determining how carrier size influences toxicity is important to understanding if current pesticide risk assessments are sufficient to protect against products that incorporate encapsulation technology. Here, a commercial pyrethroid CS pesticide with lambda-cyhalothrin (λ-Cy) as the a.i. was separated into two suspensions, a fraction consisting of nano-sized capsules (~250 nm) and a fraction of micron-sized capsules (~2200 nm) in order to investigate the influence of capsule size on toxicity to embryonic zebrafish, Danio rerio. Toxicity was evaluated 24h after exposure to equivalent amounts of a.i. by the presence and severity of pyrethroid-specific tremors, 14 sublethal developmental impacts and mortality. Fish exposed to greater than 20 μg a.i. L(-1) technical λ-Cy or formulated product experienced curvature of the body axis, pericardial edema, craniofacial malformations, and mortality. Exposure to the unfractionated formulation, micro fraction, nano fraction and technical a.i. resulted in no significant differences in the occurrence of sublethal impacts or mortality; however, the technical a.i. exposure resulted in significantly less fish experiencing tremors and shorter tremors compared to any of the formulated product exposures. This suggests that the capsule size does not influence the toxic response of the entrapped λ-Cy, but the presence or absence of the capsules does. Testing across other encapsulated products is needed to determine if size does not have influence on toxicity regardless of encapsulation technology. Copyright © 2015 Elsevier Ltd. All rights reserved.
Yan, Lei; Wang, Xin-Ying; Wan, Na; Wu, Pei-Ling
2017-04-01
To compare the incidence of postoperative pain of chronic periapical periodontitis patients with root canal therapy between Han and Uygur, and the effect of ibuprofen in reducing endodontic flare-up after single-visit root canal therapy between Uyghur and Han patients with chronic apical periodontitis, in order to provide a basis for clinical administration. Two hundred and fifty Uyghur and 250 Han patients with chronic apical periodontitis in their incisor, canine and premolar were collected, and randomly divided into 2 groups: experimental group and control group. After single-visit root canal therapy, Uyghur patients in the experimental group (UEG) and Han patients in the experimental group (HEG) took ibuprofen capsules according to the drug instructions; while Uyghur patients in the control group (UCG) and Han patients in the control group(HCG) took placebo capsules. Both doctors and patient kept blind from the drug capsules and group of the patients. The incidence, degree of endodontic Flare-up at 6, 12, 24, 48, 72 hours and 1 week after root canal therapy were recorded and analyzed by χ 2 test using SPSS11.0 software package. During the experiment, the incidence of E flare-up in Uygur patients was higher than in Han patients; the incidence of E flare-up in different groups in orders from high to low was: UCG>HCG>UEG>HEG. Chi-square test showed that there were significant differences between the two groups. In view of time distribution, most of flare-up happened between 24~48 hours after root canal therapy with the highest degree in all 4 groups. Regardless of the incidence or degree of flare-up, HEG and HCG were significantly greater than UEG and UCG. Ibuprofen can reduce and prevent flare-up for both Uyghur and Han patients, but it has better effect on Han patients.
A Boilerplate Capsule Test Technique for the Orion Parachute Test Program
NASA Technical Reports Server (NTRS)
Moore, James W.; Fraire, Usbaldo, Jr.
2013-01-01
The test program developing parachutes for the Orion/MPCV includes drop tests of a Parachute Test Vehicle designed to emulate the wake of the Orion capsule. Delivery of this test vehicle to the initial velocity, altitude, and orientation required for the test is a difficult problem involving multiple engineering disciplines. The available delivery of aircraft options imposed constraints on the test vehicle development and concept of operations. This paper describes the development of this test technique. The engineering challenges include the extraction from an aircraft and separation of two aerodynamically unstable vehicles, one of which will be delivered to a specific orientation with reasonably small rates. The desired attitude is achieved by precisely targeting the separation point using on-board monitoring of the motion. The design of the test vehicle is described. The trajectory simulations and other analyses used to develop this technique and predict the behavior of the test article are reviewed in detail. The application of the technique on several successful drop tests is summarized.
Effects of preheat and mix on the fuel adiabat of an imploding capsule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, B.; Kwan, T. J. T.; Wang, Y. M.
We demonstrate the effect of preheat, hydrodynamic mix and vorticity on the adiabat of the deuterium-tritium (DT) fuel in fusion capsule experiments. We show that the adiabat of the DT fuel increases resulting from hydrodynamic mixing due to the phenomenon of entropy of mixture. An upper limit of mix, M clean=M DT ≥ 0:98 is found necessary to keep the DT fuel on a low adiabat. We demonstrate in this study that the use of a high adiabat for the DT fuel in theoretical analysis and with the aid of 1D code simulations could explain some aspects of 3D effectsmore » and mix in capsule implosion. Furthermore, we can infer from our physics model and the observed neutron images the adiabat of the DT fuel in the capsule and the amount of mix produced on the hot spot.« less
Effects of preheat and mix on the fuel adiabat of an imploding capsule
Cheng, B.; Kwan, T. J. T.; Wang, Y. M.; ...
2016-12-01
We demonstrate the effect of preheat, hydrodynamic mix and vorticity on the adiabat of the deuterium-tritium (DT) fuel in fusion capsule experiments. We show that the adiabat of the DT fuel increases resulting from hydrodynamic mixing due to the phenomenon of entropy of mixture. An upper limit of mix, M clean=M DT ≥ 0:98 is found necessary to keep the DT fuel on a low adiabat. We demonstrate in this study that the use of a high adiabat for the DT fuel in theoretical analysis and with the aid of 1D code simulations could explain some aspects of 3D effectsmore » and mix in capsule implosion. Furthermore, we can infer from our physics model and the observed neutron images the adiabat of the DT fuel in the capsule and the amount of mix produced on the hot spot.« less
Lucky, A W; McGuire, J; Nydorf, E; Halpert, G; Nuck, B A
1986-01-01
The hamster flank organ has served as a model to study androgen-dependent responses of the skin, but the quantitative response of hair follicles to androgenic stimulation has been neglected. We assayed the hair follicle response to testosterone (T) and compared it to the response of the sebaceous glands and of the dermal pigment in the Golden Syrian hamster flank organ. Because of biologic variation in male animals and uneven absorption of hormone from parenteral injections, we implanted silastic capsules 0.25, 0.5, 1, and 2 cm in length filled with crystalline T subcutaneously into female hamsters for 6 weeks. Hair follicle response to T was more sensitive than sebaceous gland or pigment. Diameters of hairs under the sebaceous gland increased significantly from control values of 27.7 +/- 1.0 micron to 38.0 +/- 1.6 micron at the lowest dose of T tested, the 0.25-cm capsule (p less than 0.001). There was an increase in the absolute number of hairs under the sebaceous gland as the flank organ enlarged, from 27.9 +/- 9.9 control to 55.3 +/- 5.8 with the 2-cm T capsule. There was no concomitant increase in hair density, 14.4 +/- 3.5 hairs/mm control vs 12.5 +/- 1.1 hairs/mm with the 2-cm capsule. Hair follicles lateral to the sebaceous gland did not show the same response to androgen stimulation. Sebaceous gland and pigmentation responded in a dose-dependent fashion, the maximum effect being achieved with a 1-cm T capsule. We conclude that T affects hair by specifically stimulating growth of individual hairs physically under the sebaceous gland. As the whole flank organ enlarges more hairs are recruited to become larger but no new follicles appear. These studies also confirm that there are different sensitivities to androgen within the various androgen-dependent components of the hamster flank organ, with increase in hair diameter being highly sensitive. This model should be useful for the specific and quantitative assessment of androgenic and antiandrogenic substances on hair growth and ultimately by useful for therapy of hirsutism.
An empirical study of the toxic capsule crisis in China: risk perceptions and behavioral responses.
Feng, Tianjun; Keller, L Robin; Wu, Ping; Xu, Yifan
2014-04-01
The outbreak of the toxic capsule crisis during April 2012 aroused widespread public concern about the risk of chromium-contaminated capsules and drug safety in China. In this article, we develop a conceptual model to investigate risk perceptions of the pharmaceutical drug capsules and behavioral responses to the toxic capsule crisis and the relationship between associated factors and these two variables. An online survey was conducted to test the model, including questions on the measures of perceived efficacy of the countermeasures, trust in the State FDA (Food and Drug Administration), trust in the pharmaceutical companies, trust in the pharmaceutical capsule producers, risk perception, concern, need for information, information seeking, and risk avoidance. In general, participants reported higher levels of risk perception, concern, and risk avoidance, and lower levels of trust in the three different stakeholders. The results from the structural equation modeling procedure suggest that perceived efficacy of the countermeasures is a predictor of each of the three trust variables; however, only trust in the State FDA has a dampening impact on risk perception. Both risk perception and information seeking are significant determinants of risk avoidance. Risk perception is also positively related to concern. Information seeking is positively related to both concern and need for information. The theoretical and policy implications are also discussed. © 2013 Society for Risk Analysis.
Al-Numani, Dina; Scarsi, Claudia; Ducharme, Murray P
2016-02-01
To assess the bioequivalence (BE) potential under fasting conditions between levothyroxine soft capsules and the European reference tablet formulation. Two studies were conducted to assess the BE potential as per European regulations. Study 1 was a two-way crossover BE study comparing a high strength of levothyroxine soft capsules versus levothyroxine tablets (200 μg), while study 2 was a three-way crossover dosage form proportionality study between low, medium, and high strengths of soft capsules. 70 healthy adult subjects participated in the two studies. Each treatment consisted of a 600-μg dose of levothyroxine sodium, administered under fasting conditions. Blood samples were collected for levothyroxine (T4) assay prior to dosing and up to 72 hours post dose. A washout of 35 days separated treatments in each study. Pharmacokinetics was assessed using noncompartmental methods. A total of 61 subjects completed the studies. Baseline-adjusted total T4 ratios (test/reference) and 90% confidence intervals (CIs) between soft capsules and tablets were within 80.00 - 125.00%. Comparison of the three strengths of soft capsules indicated pharmacokinetic equivalence between them (ratios and 90% CIs were contained within 80.00 - 125.00%). Overall, levothyroxine sodium was well tolerated with all products when given as single oral doses of 600 μg, except for 1 serious adverse event of secondary bacteremia reported in study 2, deemed not to be related to treatment. Levothyroxine soft capsules meet BE criteria in terms of systemic exposure when compared to a European reference tablet under fasting conditions in healthy volunteers.
On-the-fly detection of images with gastritis aspects in magnetically guided capsule endoscopy
NASA Astrophysics Data System (ADS)
Mewes, P. W.; Neumann, D.; Juloski, A. L.; Angelopoulou, E.; Hornegger, J.
2011-03-01
Capsule Endoscopy (CE) was introduced in 2000 and has since become an established diagnostic procedure for the small bowel, colon and esophagus. For the CE examination the patient swallows the capsule, which then travels through the gastrointestinal tract under the influence of the peristaltic movements. CE is not indicated for stomach examination, as the capsule movements can not be controlled from the outside and the entire surface of the stomach can not be reliably covered. Magnetically-guided capsule endoscopy (MGCE) was introduced in 2010. For the MGCE procedure the stomach is filled with water and the capsule is navigated from the outside using an external magnetic field. During the examination the operator can control the motion of the capsule in order to obtain a sufficient number of stomach-surface images with diagnostic value. The quality of the examination depends on the skill of the operator and his ability to detect aspects of interest in real time. We present a novel computer-assisted diagnostic-procedure (CADP) algorithm for indicating gastritis pathologies in the stomach during the examination. Our algorithm is based on pre-processing methods and feature vectors that are suitably chosen for the challenges of the MGCE imaging (suspended particles, bubbles, lighting). An image is classified using an ada-boost trained classifier. For the classifier training, a number of possible features were investigated. Statistical evaluation was conducted to identify relevant features with discriminative potential. The proposed algorithm was tested on 12 video sequences stemming from 6 volunteers. A mean detection rate of 91.17% was achieved during leave-one out cross-validation.
NASA Technical Reports Server (NTRS)
Davidian, Kenneth J.; Dieck, Ronald H.; Chuang, Isaac
1987-01-01
A preliminary uncertainty analysis was performed for the High Area Ratio Rocket Nozzle test program which took place at the altitude test capsule of the Rocket Engine Test Facility at the NASA Lewis Research Center. Results from the study establish the uncertainty of measured and calculated parameters required for the calculation of rocket engine specific impulse. A generalized description of the uncertainty methodology used is provided. Specific equations and a detailed description of the analysis is presented. Verification of the uncertainty analysis model was performed by comparison with results from the experimental program's data reduction code. Final results include an uncertainty for specific impulse of 1.30 percent. The largest contributors to this uncertainty were calibration errors from the test capsule pressure and thrust measurement devices.
NASA Technical Reports Server (NTRS)
Davidian, Kenneth J.; Dieck, Ronald H.; Chuang, Isaac
1987-01-01
A preliminary uncertainty analysis has been performed for the High Area Ratio Rocket Nozzle test program which took place at the altitude test capsule of the Rocket Engine Test Facility at the NASA Lewis Research Center. Results from the study establish the uncertainty of measured and calculated parameters required for the calculation of rocket engine specific impulse. A generalized description of the uncertainty methodology used is provided. Specific equations and a detailed description of the analysis are presented. Verification of the uncertainty analysis model was performed by comparison with results from the experimental program's data reduction code. Final results include an uncertainty for specific impulse of 1.30 percent. The largest contributors to this uncertainty were calibration errors from the test capsule pressure and thrust measurement devices.
Ermer, James; Corcoran, Mary; Lasseter, Kenneth
2016-01-01
Background: This open-label, crossover study examined lisdexamfetamine dimesylate (LDX) and d-amphetamine pharmacokinetics in healthy adults after administration of an intact LDX capsule or after the capsule was emptied into orange juice or yogurt and the contents consumed. Methods: Healthy adult volunteers (N = 30) were administered a 70-mg LDX capsule or the contents of a 70-mg capsule mixed with yogurt or orange juice using a 3-way crossover design. Blood samples were collected serially for up to 96 hours after dose. Pharmacokinetic endpoints included maximum plasma concentration (Cmax) and area under the plasma concentration versus time curve from zero to infinity (AUC0–∞) or to last assessment (AUClast). Relative LDX and d-amphetamine bioavailabilities from the contents of a 70-mg LDX capsule mixed with orange juice or yogurt were compared with those from the intact LDX capsule using bioequivalence-testing procedures. Results: Geometric least squares mean ratios (90% confidence intervals [CIs]) for d-amphetamine (active moiety) were within the prespecified bioequivalence range (0.80–1.25) when the contents of a 70-mg LDX capsule were mixed with orange juice [Cmax: 0.971 (0.945, 0.998); AUC0–∞: 0.986 (0.955, 1.019); AUClast: 0.970 (0.937, 1.004)] or yogurt [Cmax: 0.970 (0.944, 0.997); AUC0–∞: 0.945 (0.915, 0.976); AUClast: 0.944 (0.912, 0.977)]. Geometric least squares mean ratios (90% CIs) for LDX (inactive prodrug) were below the accepted range when the contents of a 70-mg LDX capsule were mixed with orange juice [Cmax: 0.641 (0.582, 0.707); AUC0–∞: 0.716 (0.647, 0.792); AUClast: 0.708 (0.655, 0.766)]; the lower 90% CI for Cmax [0.828 (0.752, 0.912)] was below the accepted range when the contents of a 70-mg LDX capsule were mixed with yogurt. Conclusions: Relative bioavailability of d-amphetamine (the active moiety) did not differ across administrations, which suggests that emptying an LDX capsule into orange juice or yogurt and consuming it is an alternative to intact capsules. PMID:27661399
Liquid-Solid Self-Lubricated Coatings
NASA Astrophysics Data System (ADS)
Armada, S.; Schmid, R.; Equey, S.; Fagoaga, I.; Espallargas, N.
2013-02-01
Self-lubricated coatings have been a major topic of interest in thermal spray in the last decades. Self-lubricated coatings obtained by thermal spray are exclusively based on solid lubricants (PTFE, h-BN, graphite, MoS2, etc.) embedded in the matrix. Production of thermal spray coatings containing liquid lubricants has not yet been achieved because of the complexity of keeping a liquid in a solid matrix during the spraying process. In the present article, the first liquid-solid self-lubricating thermal spray coatings are presented. The coatings are produced by inserting lubricant-filled capsules inside a polymeric matrix. The goal of the coating is to release lubricant to the system when needed. The first produced coatings consisted solely of capsules for confirming the feasibility of the process. For obtaining such a coating, the liquid-filled capsules were injected in the thermal spray flame without any other feedstock material. Once the concept and the idea were proven, a polymer was co-sprayed together with the capsules to obtain a coating containing the lubricant-filled capsules distributed in the solid polymeric matrix. The coatings and the self-lubricated properties have been investigated by means of optical microscopy, Scanning Electron Microscopy, and tribological tests.
Exploding a myth: the capsule dehiscence mechanism and the function of pseudostomata in Sphagnum.
Duckett, Jeffrey G; Pressel, Silvia; P'ng, Ken M Y; Renzaglia, Karen S
2009-01-01
The nineteenth century air-gun explanation for explosive spore discharge in Sphagnum has never been tested experimentally. Similarly, the function of the numerous stomata ubiquitous in the capsule walls has never been investigated. Both intact and pricked Sphagnum capsules, that were allowed to dry out, all dehisced over an 8-12 h period during which time the stomatal guard cells gradually collapsed and their potassium content, measured by X-ray microanalysis in a cryoscanning electron microscope, gradually increased. By contrast, guard cell potassium fell in water-stressed Arabidopsis. The pricking experiments demonstrate that the air-gun notion for explosive spore discharge in Sphagnum is inaccurate; differential shrinkage of the capsule walls causes popping off the rigid operculum. The absence of evidence for a potassium-regulating mechanism in the stomatal guard cells and their gradual collapse before spore discharge indicates that their sole role is facilitation of sporophyte desiccation that ultimately leads to capsule dehiscence. Our novel functional data on Sphagnum, when considered in relation to bryophyte phylogeny, suggest the possibility that stomata first appeared in land plants as structures that facilitated sporophyte drying out before spore discharge and only subsequently acquired their role in the regulation of gaseous exchange.
Vallée, Isabelle; Macé, Pauline; Forbes, Lorry; Scandrett, Brad; Durand, Benoit; Gajadhar, Alvin; Boireau, Pascal
2007-07-01
Routine diagnosis of animal trichinellosis for food safety and trade relies on a method of artificial digestion to free Trichinella muscle larvae from meat for subsequent identification by microscopy. As part of a quality control system, the French National Reference Laboratory (NRL) initiated ring trials to determine the sensitivity of the test performed in the 72 routine diagnostic laboratories in France. A method was devised to obtain calibrated meat samples containing known numbers of capsules with Trichinella spiralis muscle larvae. This method was based on an incomplete artificial digestion of Trichinella-infected mice carcasses to allow the collection of intact Trichinella capsules. Capsules were placed into a meatball of 100 +/- 2 g of pork and horsemeat to produce proficiency samples. Three categories of samples were prepared: small (3 to 5 capsules), medium (7 to 10), and large (12 to 15). The sensitivity was expressed as the percentage of muscle larvae recovered from each proficiency sample. Reproducibility was tested with ring trials organized between two NRLs (France and Canada), and a reference sensitivity of 84.9% was established. National ring trials were then organized in France, with the 72 routine diagnostic laboratories each receiving four proficiency samples per session. After five sessions, an improvement in the digest test sensitivity was observed. Results at the fifth session indicated sensitivities of 78.60% +/- 23.70%, 81.19% +/- 19.59%, and 80.52% +/- 14.71% muscle larvae for small, medium, and large samples, respectively. This study supports the use of proficiency samples to accurately evaluate the performance of routine diagnostic laboratories that conduct digestion tests for animal trichinellosis diagnosis.
Interplay Between Capsule Expression and Uracil Metabolism in Streptococcus pneumoniae D39
Carvalho, Sandra M.; Kloosterman, Tomas G.; Manzoor, Irfan; Caldas, José; Vinga, Susana; Martinussen, Jan; Saraiva, Lígia M.; Kuipers, Oscar P.; Neves, Ana R.
2018-01-01
Pyrimidine nucleotides play an important role in the biosynthesis of activated nucleotide sugars (NDP-sugars). NDP-sugars are the precursors of structural polysaccharides in bacteria, including capsule, which is a major virulence factor of the human pathogen S. pneumoniae. In this work, we identified a spontaneous non-reversible mutant of strain D39 that displayed a non-producing capsule phenotype. Whole-genome sequencing analysis of this mutant revealed several non-synonymous single base modifications, including in genes of the de novo synthesis of pyrimidines and in the −10 box of capsule operon promoter (Pcps). By directed mutagenesis we showed that the point mutation in Pcps was solely responsible for the drastic decrease in capsule expression. We also demonstrated that D39 subjected to uracil deprivation shows increased biomass and decreased Pcps activity and capsule amounts. Importantly, Pcps expression is further decreased by mutating the first gene of the de novo synthesis of pyrimidines, carA. In contrast, the absence of uracil from the culture medium showed no effect on the spontaneous mutant strain. Co-cultivation of the wild-type and the mutant strain indicated a competitive advantage of the spontaneous mutant (non-producing capsule) in medium devoid of uracil. We propose a model in that uracil may act as a signal for the production of different capsule amounts in S. pneumoniae. PMID:29599757
Interplay Between Capsule Expression and Uracil Metabolism in Streptococcus pneumoniae D39.
Carvalho, Sandra M; Kloosterman, Tomas G; Manzoor, Irfan; Caldas, José; Vinga, Susana; Martinussen, Jan; Saraiva, Lígia M; Kuipers, Oscar P; Neves, Ana R
2018-01-01
Pyrimidine nucleotides play an important role in the biosynthesis of activated nucleotide sugars (NDP-sugars). NDP-sugars are the precursors of structural polysaccharides in bacteria, including capsule, which is a major virulence factor of the human pathogen S. pneumoniae . In this work, we identified a spontaneous non-reversible mutant of strain D39 that displayed a non-producing capsule phenotype. Whole-genome sequencing analysis of this mutant revealed several non-synonymous single base modifications, including in genes of the de novo synthesis of pyrimidines and in the -10 box of capsule operon promoter (P cps ). By directed mutagenesis we showed that the point mutation in P cps was solely responsible for the drastic decrease in capsule expression. We also demonstrated that D39 subjected to uracil deprivation shows increased biomass and decreased P cps activity and capsule amounts. Importantly, P cps expression is further decreased by mutating the first gene of the de novo synthesis of pyrimidines, carA . In contrast, the absence of uracil from the culture medium showed no effect on the spontaneous mutant strain. Co-cultivation of the wild-type and the mutant strain indicated a competitive advantage of the spontaneous mutant (non-producing capsule) in medium devoid of uracil. We propose a model in that uracil may act as a signal for the production of different capsule amounts in S. pneumoniae .
2012-05-17
CAPE CANAVERAL, Fla. – Umbilical lines connect the strongback to the SpaceX Falcon 9 rocket which has just arrived on the pad at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-05-17
CAPE CANAVERAL, Fla. – A strongback lifts the SpaceX Falcon 9 rocket into a vertical position on the pad at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-05-17
CAPE CANAVERAL, Fla. – Preparations are under way to roll the SpaceX Falcon 9 rocket out of the processing facility to the pad at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-04-29
CAPE CANAVERAL, Fla. – Partially hidden behind a flame and exhaust deflector, the SpaceX Falcon 9 rocket stands at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex Photo credit: NASA/Jim Grossmann
2012-05-18
CAPE CANAVERAL, Fla. – A photographer sets up his remote camera at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. In the background, final preparations are under way to launch the SpaceX Falcon 9 rocket. Liftoff with the Dragon capsule on top is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Ken Thornsley
2012-05-17
CAPE CANAVERAL, Fla. – The SpaceX Falcon 9 rocket rolls between the lightning protection system towers surrounding the pad at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the SpaceX Dragon capsule aboard is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Jim Grossmann
2012-05-18
CAPE CANAVERAL, Fla. – A strongback provides connections to the SpaceX Falcon 9 rocket as final preparations for launch are completed at Space Launch Complex-40 on Cape Canaveral Air Force Station in Florida. Liftoff with the Dragon capsule on top is set for 4:55 a.m. EDT on May 19. The launch will be the company's second demonstration test flight for NASA's Commercial Orbital Transportation Services Program, or COTS. During the flight, the capsule will conduct a series of check-out procedures to test and prove its systems, including rendezvous and berthing with the International Space Station. If the capsule performs as planned, the cargo and experiments it is carrying will be transferred to the station. The cargo includes food, water and provisions for the station’s Expedition crews, such as clothing, batteries and computer equipment. Under COTS, NASA has partnered with two aerospace companies to deliver cargo to the station. For more information, visit http://www.nasa.gov/spacex. Photo credit: NASA/Ken Thornsley
Zhou, Teng; Han, Guoqiang; Li, Bing Nan; Lin, Zhizhe; Ciaccio, Edward J; Green, Peter H; Qin, Jing
2017-06-01
Celiac disease is one of the most common diseases in the world. Capsule endoscopy is an alternative way to visualize the entire small intestine without invasiveness to the patient. It is useful to characterize celiac disease, but hours are need to manually analyze the retrospective data of a single patient. Computer-aided quantitative analysis by a deep learning method helps in alleviating the workload during analysis of the retrospective videos. Capsule endoscopy clips from 6 celiac disease patients and 5 controls were preprocessed for training. The frames with a large field of opaque extraluminal fluid or air bubbles were removed automatically by using a pre-selection algorithm. Then the frames were cropped and the intensity was corrected prior to frame rotation in the proposed new method. The GoogLeNet is trained with these frames. Then, the clips of capsule endoscopy from 5 additional celiac disease patients and 5 additional control patients are used for testing. The trained GoogLeNet was able to distinguish the frames from capsule endoscopy clips of celiac disease patients vs controls. Quantitative measurement with evaluation of the confidence was developed to assess the severity level of pathology in the subjects. Relying on the evaluation confidence, the GoogLeNet achieved 100% sensitivity and specificity for the testing set. The t-test confirmed the evaluation confidence is significant to distinguish celiac disease patients from controls. Furthermore, it is found that the evaluation confidence may also relate to the severity level of small bowel mucosal lesions. A deep convolutional neural network was established for quantitative measurement of the existence and degree of pathology throughout the small intestine, which may improve computer-aided clinical techniques to assess mucosal atrophy and other etiologies in real-time with videocapsule endoscopy. Copyright © 2017 Elsevier Ltd. All rights reserved.
Development of a Smart Release Algorithm for Mid-Air Separation of Parachute Test Articles
NASA Technical Reports Server (NTRS)
Moore, James W.
2011-01-01
The Crew Exploration Vehicle Parachute Assembly System (CPAS) project is currently developing an autonomous method to separate a capsule-shaped parachute test vehicle from an air-drop platform for use in the test program to develop and validate the parachute system for the Orion spacecraft. The CPAS project seeks to perform air-drop tests of an Orion-like boilerplate capsule. Delivery of the boilerplate capsule to the test condition has proven to be a critical and complicated task. In the current concept, the boilerplate vehicle is extracted from an aircraft on top of a Type V pallet and then separated from the pallet in mid-air. The attitude of the vehicles at separation is critical to avoiding re-contact and successfully deploying the boilerplate into a heatshield-down orientation. Neither the pallet nor the boilerplate has an active control system. However, the attitude of the mated vehicle as a function of time is somewhat predictable. CPAS engineers have designed an avionics system to monitor the attitude of the mated vehicle as it is extracted from the aircraft and command a release when the desired conditions are met. The algorithm includes contingency capabilities designed to release the test vehicle before undesirable orientations occur. The algorithm was verified with simulation and ground testing. The pre-flight development and testing is discussed and limitations of ground testing are noted. The CPAS project performed a series of three drop tests as a proof-of-concept of the release technique. These tests helped to refine the attitude instrumentation and software algorithm to be used on future tests. The drop tests are described in detail and the evolution of the release system with each test is described.
2003-12-19
Orion Capsule and Launch Abort System (LAS) installed in the NASA Glenn 8x6 Supersonic Wind Tunnel for testing. This test is an Aero Acoustic test of the LAS. Pictured is the calibration of the model's angle of attack
2003-12-19
Orion Capsule and Launch Abort System (LAS) installed in the NASA Glenn 8x6 Supersonic Wind Tunnel for testing. This test is an Aero Acoustic test of the LAS. Pictured is the calibration of the model's angle of attack
Simulations of fill tube effects on the implosion of high-foot NIF ignition capsules
NASA Astrophysics Data System (ADS)
Dittrich, T. R.; Hurricane, O. A.; Berzak-Hopkins, L. F.; Callahan, D. A.; Casey, D. T.; Clark, D.; Dewald, E. L.; Doeppner, T.; Haan, S. W.; Hammel, B. A.; Harte, J. A.; Hinkel, D. E.; Kozioziemski, B. J.; Kritcher, A. L.; Ma, T.; Nikroo, A.; Pak, A. E.; Parham, T. G.; Park, H.-S.; Patel, P. K.; Remington, B. A.; Salmonson, J. D.; Springer, P. T.; Weber, C. R.; Zimmerman, G. B.; Kline, J. L.
2016-05-01
Encouraging results have been obtained using a strong first shock during the implosion of carbon-based ablator ignition capsules. These “high-foot” implosion results show that capsule performance deviates from 1D expectations as laser power and energy are increased. A possible cause of this deviation is the disruption of the hot spot by jets originating in the capsule fill tube. Nominally, a 10 μm outside diameter glass (SiO2) fill tube is used in these implosions. Simulations indicate that a thin coating of Au on this glass tube may lessen the hotspot disruption. These results and other mitigation strategies will be presented.
Unsteady Pressures on a Generic Capsule Shape
NASA Technical Reports Server (NTRS)
Burnside, Nathan; Ross, James C.
2015-01-01
While developing the aerodynamic database for the Orion spacecraft, the low-speed flight regime (transonic and below) proved to be the most difficult to predict and measure accurately. The flow over the capsule heat shield in descent flight was particularly troublesome for both computational and experimental efforts due to its unsteady nature and uncertainty about the boundary layer state. The data described here were acquired as part of a study to improve the understanding of the overall flow around a generic capsule. The unsteady pressure measurements acquired on a generic capsule shape are presented along with a discussion about the effects of various flight conditions and heat-shield surface roughness on the resulting pressure fluctuations.
Defect-induced mix experiment for NIF
NASA Astrophysics Data System (ADS)
Schmitt, M. J.; Bradley, P. A.; Cobble, J. A.; Hsu, S. C.; Krasheninnikova, N. S.; Kyrala, G. A.; Magelssen, G. R.; Murphy, T. J.; Obrey, K. A.; Tregillis, I. L.; Wysocki, F. J.; Finnegan, S. M.
2013-11-01
The Defect Induced Mix Experiment (DIME-II) will measure the implosion and mix characteristics of CH capsules filled with 5 atmospheres of DT by incorporating mid-Z dopant layers of Ge and Ga. This polar direct drive (PDD) experiment also will demonstrate the filling of a CH capsule at target chamber center using a fill tube. Diagnostics for these experiments include areal x-ray backlighting to obtain early time images of the implosion trajectory and a multiple-monochromatic imager (MMI) to collect spectrally-resolved images of the capsule dopant line emission near bangtime. The inclusion of two (or more) thin dopant layers at separate depths within the capsule shell facilitates spatial correlation of mix between the layers and the hot gas core on a single shot. The dopant layers are typically 2 μm thick and contain dopant concentrations of 1.5%. Three dimensional Hydra simulations have been performed to assess the effects of PDD asymmetry on capsule performance.
IRRADIATION-CAPSULE STUDY OF URANIUM MONOCARBIDE
DOE Office of Scientific and Technical Information (OSTI.GOV)
Price, R.B.; Stahl, D.; Stang, J.H.
1960-03-01
Small cylindrical specimens of enriched UC were irradiated to evaluate usefulness as a high-temperature fuel for stationary power reactors. Detailed thermal and nuclear analyses were made to arrive at an appropriate capsule design on the basis of target specimen center-line temperature ( approximately 1500 deg F), specimen surface temperature (1100 deg F), specimen composition (U--5 wt.% C), and acapsule o.d. of 1.125 in. Temperature data from thermocouples inside the capsule indicated that five of the six capsules irradiated operated at close to the design conditions. Irradiation periods for individual capsules were varied to give burnups ranging from 1,000 to 20,000more » Mwd/t of U. Preliminary evidence indicates that this range of burnups was achieved. By using temperature and heat-flux data from the actual irradiations to estimate effective in-pile specimen thermal conductivities, it was found that the conductivity did not appear to vary during the exposures. (auth)« less
Encapsulation system for the immunoisolation of living cells
NASA Technical Reports Server (NTRS)
Lacik, Igor (Inventor); Brissova, Marcela (Inventor); Wang, Taylor G. (Inventor); Anikumar, Amrutur V. (Inventor); Prokop, Ales (Inventor); Powers, Alvin C. (Inventor)
1999-01-01
The present invention is drawn to a composition of matter comprising high viscosity sodium alginate, cellulose sulfate and a multi-component polycation. Additionally, the present invention provides methods for making capsules, measuring capsule permeability to immunologically-relevant proteins and treating disease in an animal using encapsulated cells. Over one thousand combinations of polyanions and polycations were examined as polymer candidates suitable for encapsulation of living cells and thirty-three pairs were effective. The combination of sodium alginate, cellulose sulfate, poly(methylene-co-guanidine) hydrochloride, calcium chloride, and sodium chloride produced the most desirable results. Pancreatic islets encapsulated in this multicomponent capsule demonstrated glucose-stimulated insulin secretion in vitro and reversed diabetes without stimulating immune reaction in mice. The capsule formulation and system of the present invention allows independent adjustments of capsule size, wall thickness, mechanical strength and permeability, and offers distinct advantages for immunoisolating cells.
Qing, Shan; Gao, Lin; Zhang, Li; Jia, Jian-Ping; Liu, Xin-Min; Ji, Shao-Liang; Yang, Xiao-Hui
2013-11-01
By comprehensive review and analysis of post-marketing clinical research on the efficacy and safety,we concluded that Fufang Zaoren capsule has certain therapeutic effects for insomnia, although current clinical research design needs improving. The post-marketing clinical studies also showed that it causes several adverse reactions at the recommended doses, such as chills, fever, dizziness, nausea, shortness of breath, chest tightness and palpitations, whereas high doses of Fufang Zaoren capsule can cause delayed extrapyramidal symptoms. Health Canada government website also prompted the L-tetrahydropalmatine in Fufang Zaoren capsule caused liver damage in pregnant women. The authors summarized the risk points, factors and risk control in the clinical use of Fufang Zaoren capsule and also present their perspective on the research status, existing problems and corresponding countermeasures in the post-marketing clinical re-evaluation of traditional Chinese medicine.
NASA Technical Reports Server (NTRS)
Creagh, J. W. R.; Smith, J. R.
1973-01-01
Uranium carbide fueled, thermionic emitter configurations were encapsulated and irradiated. One capsule contained a specimen clad with fluoride derived chemically vapor deposited (CVD) tungsten. The other capsule used a duplex clad specimen consisting of chloride derived on floride derived CVD tungsten. Both fuel pins were 16 millimeters in diameter and contained a 45.7-millimeter length of fuel.
Díaz-Rodríguez, P; Rey-Rico, A; Madry, H; Landin, M; Cucchiarini, M
2015-12-30
Viral vectors are common tools in gene therapy to deliver foreign therapeutic sequences in a specific target population via their natural cellular entry mechanisms. Incorporating such vectors in implantable systems may provide strong alternatives to conventional gene transfer procedures. The goal of the present study was to generate different hydrogel structures based on alginate (AlgPH155) and poloxamer PF127 as new systems to encapsulate and release recombinant adeno-associated viral (rAAV) vectors. Inclusion of rAAV in such polymeric capsules revealed an influence of the hydrogel composition and crosslinking temperature upon the vector release profiles, with alginate (AlgPH155) structures showing the fastest release profiles early on while over time vector release was more effective from AlgPH155+PF127 [H] capsules crosslinked at a high temperature (50°C). Systems prepared at room temperature (AlgPH155+PF127 [C]) allowed instead to achieve a more controlled release profile. When tested for their ability to target human mesenchymal stem cells, the different systems led to high transduction efficiencies over time and to gene expression levels in the range of those achieved upon direct vector application, especially when using AlgPH155+PF127 [H]. No detrimental effects were reported on either cell viability or on the potential for chondrogenic differentiation. Inclusion of PF127 in the capsules was also capable of delaying undesirable hypertrophic cell differentiation. These findings are of promising value for the further development of viral vector controlled release strategies. Copyright © 2015 Elsevier B.V. All rights reserved.
Using HT and DT gamma rays to diagnose mix in Omega capsule implosions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Schmitt, M. J.; Herrmann, H. W.; Kim, Y. H.
Experimental evidence [1] indicates that shell material can be driven into the core of Omega capsule implosions on the same time scale as the initial convergent shock. It has been hypothesized that shock-generated temperatures at the fuel/shell interface in thin exploding pusher capsules diffusively drives shell material into the gas core between the time of shock passage and bang time. Here, we propose a method to temporally resolve and observe the evolution of shell material into the capsule core as a function of fuel/shell interface temperature (which can be varied by varying the capsule shell thickness). Our proposed method usesmore » a CD plastic capsule filled with 50/50 HT gas and diagnosed using gas Cherenkov detection (GCD) to temporally resolve both the HT "clean" and DT "mix" gamma ray burn histories. Simulations using Hydra [2] for an Omega CD-lined capsule with a sub-micron layer of the inside surface of the shell pre-mixed into a fraction of the gas region produce gamma reaction history profiles that are sensitive to the depth to which this material is mixed. Furthermore, we observe these differences as a function of capsule shell thickness is proposed to determine if interface mixing is consistent with thermal diffusion λ ii~T 2/Z 2ρ at the gas/shell interface. Finally, since hydrodynamic mixing from shell perturbations, such as the mounting stalk and glue, could complicate these types of capsule-averaged temporal measurements, simulations including their effects also have been performed showing minimal perturbation of the hot spot geometry.« less
Using HT and DT gamma rays to diagnose mix in Omega capsule implosions
Schmitt, M. J.; Herrmann, H. W.; Kim, Y. H.; ...
2016-05-26
Experimental evidence [1] indicates that shell material can be driven into the core of Omega capsule implosions on the same time scale as the initial convergent shock. It has been hypothesized that shock-generated temperatures at the fuel/shell interface in thin exploding pusher capsules diffusively drives shell material into the gas core between the time of shock passage and bang time. Here, we propose a method to temporally resolve and observe the evolution of shell material into the capsule core as a function of fuel/shell interface temperature (which can be varied by varying the capsule shell thickness). Our proposed method usesmore » a CD plastic capsule filled with 50/50 HT gas and diagnosed using gas Cherenkov detection (GCD) to temporally resolve both the HT "clean" and DT "mix" gamma ray burn histories. Simulations using Hydra [2] for an Omega CD-lined capsule with a sub-micron layer of the inside surface of the shell pre-mixed into a fraction of the gas region produce gamma reaction history profiles that are sensitive to the depth to which this material is mixed. Furthermore, we observe these differences as a function of capsule shell thickness is proposed to determine if interface mixing is consistent with thermal diffusion λ ii~T 2/Z 2ρ at the gas/shell interface. Finally, since hydrodynamic mixing from shell perturbations, such as the mounting stalk and glue, could complicate these types of capsule-averaged temporal measurements, simulations including their effects also have been performed showing minimal perturbation of the hot spot geometry.« less
Using HT and DT gamma rays to diagnose mix in Omega capsule implosions
NASA Astrophysics Data System (ADS)
Schmitt, M. J.; Herrmann, H. W.; Kim, Y. H.; McEvoy, A. M.; Zylstra, A.; Hammel, B. A.; Sepke, S. M.; Leatherland, A.; Gales, S.
2016-05-01
Experimental evidence [1] indicates that shell material can be driven into the core of Omega capsule implosions on the same time scale as the initial convergent shock. It has been hypothesized that shock-generated temperatures at the fuel/shell interface in thin exploding pusher capsules diffusively drives shell material into the gas core between the time of shock passage and bang time. We propose a method to temporally resolve and observe the evolution of shell material into the capsule core as a function of fuel/shell interface temperature (which can be varied by varying the capsule shell thickness). Our proposed method uses a CD plastic capsule filled with 50/50 HT gas and diagnosed using gas Cherenkov detection (GCD) to temporally resolve both the HT “clean” and DT “mix” gamma ray burn histories. Simulations using Hydra [2] for an Omega CD-lined capsule with a sub-micron layer of the inside surface of the shell pre-mixed into a fraction of the gas region produce gamma reaction history profiles that are sensitive to the depth to which this material is mixed. An experiment to observe these differences as a function of capsule shell thickness is proposed to determine if interface mixing is consistent with thermal diffusion λii∼T2/Z2ρ at the gas/shell interface. Since hydrodynamic mixing from shell perturbations, such as the mounting stalk and glue, could complicate these types of capsule-averaged temporal measurements, simulations including their effects also have been performed showing minimal perturbation of the hot spot geometry.
Deformation of an elastic capsule in a uniform electric field
NASA Astrophysics Data System (ADS)
Karyappa, Rahul B.; Deshmukh, Shivraj. D.; Thaokar, Rochish. M.
2014-12-01
The deformation of a thin elastic capsule subjected to a uniform electric field is investigated in the Stokes flow regime. The electrohydrodynamic flow is analyzed using a perfect conductor and a perfect dielectric model for the capsule and the fluid phase, respectively. A theoretical analysis is carried out using an asymptotic expansion in the electric capillary number (Ca) (a ratio of the electric stress to the elastic tension) in the small deformation limit using the finite deformation Hooke's law. The analysis is used to determine the elasticity of polysiloxane capsules suspended in oil, the deformation of which is obtained using videography. The boundary element method is implemented to seek numerical solutions to the hydrodynamic, elastic, and electrostatics equations. The finite deformation Hooke's law, the Mooney-Rivlin, and Skalak's model for elasticity are employed. The effect of electric capillary number, unstressed geometry, and the type of membrane material on the deformation of a capsule is presented in the high Ca number limit using numerical simulation. Capsules synthesized with higher monomer concentration displayed electric stress induced wrinkling process at high electric field strengths. Burst of a capsule is characterized by poration of the polymer membrane, which could be symmetric or asymmetric at the two poles, depending upon the value of the capillary number. The results should be useful in understanding the response of elastic capsules such as red blood cells and polymerized membranes, to an electric field, in applications such as electrodeformation and electroporation. It also provides a theoretical framework for a possible way of determining the elastic parameters of a capsule.
NASA Astrophysics Data System (ADS)
Seguin, F. H.; Rinderknecht, H. G.; Rosenberg, M.; Zylstra, A.; Frenje, J.; Li, C. K.; Petrasso, R.; Marshall, F. J.; Sangster, T. C.; Hoffman, N. M.; Amendt, P. A.; Bellei, C.; Le Pape, S.; Wilks, S. C.
2014-10-01
Fusion reactions in ICF implosions of D3He-filled capsules produce 14.7-MeV D3He protons and 3-MeV DD protons. Measurements of the spatial distributions of the D3He and DD reactions are studied with a penumbral imaging system that utilizes a CR-39-based imaging detector to simultaneously record separate penumbral images of the two types of protons. Measured burn profiles are useful for studying implosion physics and provide a critical test for benchmarking simulations. Recent implosions at OMEGA of CD capsules containing 3He gas fill and SiO2 capsules containing low-pressure D3He gas were expected to have hollow D3He burn profiles (in the 3He-filled capsule, due to fuel-shell mix), but penumbral imaging showed that the reactions were centrally peaked due to enhanced ion diffusion. The imaging technique is to be implemented soon on the NIF. This work was supported in part by NLUF, DOE, and LLE.
Mohammadi, Ali Akbar; Jazayeri, Shima; Khosravi-Darani, Kianoush; Solati, Zahra; Mohammadpour, Nakisa; Asemi, Zatollah; Adab, Zohre; Djalali, Mahmoud; Tehrani-Doost, Mehdi; Hosseini, Mostafa; Eghtesadi, Shahryar
2016-11-01
The aim of this study was to determine effects of probiotic yogurt and multispecies probiotic capsule supplementation on mental health and hypothalamic-pituitary-adrenal axis in petrochemical workers. The present randomized double-blind, placebo-controlled trial was conducted on 70 petrochemical workers. Subjects were randomly divided into three groups to receive 100 g/day probiotic yogurt + one placebo capsule (n = 25) or one probiotic capsule daily + 100 g/day conventional yogurt (n = 25) or 100 g/day conventional yogurt + one placebo capsule (n = 20) for 6 weeks. Mental health parameters including general health questionnaire (GHQ) and depression anxiety and stress scale (DASS) scores were measured. Fasting blood samples were obtained at the beginning and 6 weeks after the intervention to quantify hypothalamic-pituitary-adrenal axis. After 6 weeks of intervention, a significant improvement of GHQ was observed in the probiotic yogurt (18.0 ± 1.5 vs. 13.5 ± 1.9, P = 0.007) and in the probiotic capsule group (16.9 ± 1.8 vs. 9.8 ± 1.9, P = 0.001), as well as a significant improvement in DASS scores in the probiotic yogurt (23.3 ± 3.7 vs. 13.0 ± 3.7, P = 0.02) and the probiotic capsule group (18.9 ± 3.2 vs. 9.4 ± 4.0, P = 0.006). However, there was no significant improvement in the conventional yogurt group (P = 0.05 for GHQ and P = 0.08 for DASS). The consumption of probiotic yogurt or a multispecies probiotic capsule had beneficial effects on mental health parameters in petrochemical workers.
Astesana, Diego M; Zimmermann, Jorge A; Frizzo, Laureano S; Zbrun, María V; Blajman, Jesica E; Berisvil, Ayelén P; Romero-Scharpen, Analía; Signorini, Marcelo L; Rosmini, Marcelo R; Soto, Lorena P
2018-03-17
The aim of this study was to evaluate different production methodologies of probiotic macrocapsules with high bacterial densities destined to lactating calves. Three types of capsules containing Lactobacillus casei DSPV318T and Lactobacillus plantarum DSPV354T were prepared from an overnight culture in whey medium: (1) mixing the culture with calcium alginate and then, reincubating the capsules in whey (RC); (2) concentrating the biomass by centrifugation and mixing the pellet with calcium alginate (CC) at different concentrations with respect to the initial culture (5X and 12.5X); (3) CC with cryoprotectants: whey permeate (Per) and glycerol (Gly). Chitosan coating was evaluated. Capsules were freeze-dried and viability was assessed before freezing, after freeze-drying and every two weeks for 84 days of storage at room temperature, 4°C and -20°C. CC showed higher cell densities than RC. Storage temperature affected viability: greater viability at lower temperature. Moreover, the effect of temperature was influenced by other factors, such as capsule coating, culture neutralization and cryoprotectants. Coating improved viability at room temperature; however no effect was observed at 4°C. Culture neutralization allowed greater survival during storage. Cryoprotectants improved viability during freezing, but they also generated a positive or negative effect depending on storage temperature. The best results were: at refrigeration Gly12.5X exhibited counts above 10 9 CFU/capsule until day 70 and Per12.5X until day 56 of storage and at -20°C Gly12.5X showed counts above 10 9 CFU/capsule until the end of the study (84 days). A 10 9 CFU capsule is the daily dose per calf which would facilitate the administration of this probiotic inoculum to field animals. Copyright © 2017 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.
Zhou, Quan; Tao, Jing; Song, Huamei; Chen, Aihua; Yang, Huaijie; Zuo, Manzhen; Li, Hairong
2016-12-01
Kuntai capsule has been widely used for the treatment of menopausal syndrome in China for long time. We conducted this review to assess efficacy and safety of Kuntai capsule for the treatment of menopausal syndrome. We searched studies in PubMed, ClinicalTrials, the Cochrane Library, China National Knowledge Infrastructure Database(CNKI), China Science and Technology Journal Database (VIP), Wan fang Database and Chinese Biomedical Literature Database(CBM) until November 20, 2014. Randomized trials on Kuntai capsule for menopausal syndrome, compared with placebo or hormone replacement therapy (HRT) were included. Two reviewers independently retrieved the randomized controlled trials (RCTs) and extracted the information. The Cochrane risk of bias method was used to assess the quality of the included studies, and a Meta-analysis was conducted with Review Manager 5.2 software. A total of 17 RCTs (1455 participants) were included. The studies were of low methodological quality. Meta-analysis indicated that there was no statistical difference in the Kupperman index (KI) [WMD=0.51, 95% CI (-0.04, 1.06)], the effective rate of KI [OR=1.21, 95% CI (0.72, 2.04)], E2 level [WMD=-15.18, 95% CI (-33.93, 3.56)], and FSH level [WMD=-3.46, 95% CI (-7.2, 0.28)] after treatment between Kuntai versus HRT group (P>0.05). However, Compared with HRT, Kuntai capsule could significantly reduce the total incidence of adverse events [OR=0.28, 95% CI (0.17, 0.45)]. Kuntai capsule may be effective for treating menopausal syndrome and lower risk of side effects. The studies we analyzed were of low methodological quality. Therefore, more strictly designed large-scale randomized clinical trials are needed to evaluate the efficacy of Kuntai capsule in menopausal syndrome. Copyright © 2016 Elsevier Ltd. All rights reserved.
Germain, M; Paquereau, L; Winterhalter, M; Hochepied, J-F; Fournier, D
2007-03-01
Uses of enzymes for therapeutic purpose or for biosensing require a well-controlled nanoenvironnement to avoid degradation by proteolytic agents, pH variations or dilution effects. A solution is encapsulation under undenaturating conditions into a nanometer sized and stable capsule. The nanometer scall decreases recognition by the reticulo-endothelial system recognition and subsequent immune reaction. Liposomes are the method of choice since they allow protein encapsulation under mild conditions. However they lack in stability. In contrast, other type of capsules exhibit strong stability but with conditions required for formation that are incompatible with enzyme integrity. Here we combine different capsule formation techniques and use liposomes as templates for further stabilization. Here we demonstrate two types of multicomposite capsules. The first type is to coat the liposome surface with polyelectrolytes followed by secondary covalent crosslinking of the polyelectrolytes multilayer. In the second type of capsules we used silica to build an inorganic shell around liposome. Both techniques allow the formation of detergent stable nanocapsules which exhibits properties protective against acetylcholinesterase protein degradation, an enzyme of much interest for pesticide detection.
Fukatsu, Takema; Hosokawa, Takahiro
2002-01-01
The Japanese common plataspid stinkbug, Megacopta punctatissima, deposits small brown particles, or symbiont capsules, on the underside of the egg mass for the purpose of transmission of symbiotic bacteria to the offspring. We investigated the microbiological aspects of the bacteria contained in the capsule, such as microbial diversity, phylogenetic placement, localization in vivo, and fitness effects on the host insect. Restriction fragment length polymorphism analysis of 16S ribosomal DNA clones revealed that a single bacterial species dominates the microbiota in the capsule. The bacterium was not detected in the eggs but in the capsules, which unequivocally demonstrated that the bacterium is transmitted to the offspring of the insect orally rather than transovarially, through probing of the capsule content. Molecular phylogenetic analysis showed that the bacterium belongs to the γ-subdivision of the Proteobacteria. In adult insects the bacterium was localized in the posterior section of the midgut. Deprivation of the bacterium from the nymphs resulted in retarded development, arrested growth, abnormal body coloration, and other symptoms, suggesting that the bacterium is essential for normal development and growth of the host insect. PMID:11772649
Degradation of oxalate in rats implanted with immobilized oxalate oxidase.
Raghavan, K G; Tarachand, U
1986-01-20
Accumulation of oxalate leads to hyperoxaluria and calcium oxalate nephrolithiasis in man. Since oxalate is a metabolic end product in mammals, the feasibility of its enzymic degradation has been tested in vivo in rats by administering exogenous oxalate oxidase. Oxalate oxidase, isolated from banana fruit peels, in its native form was found to be non-active at the physiological pH of the recipient animal. However, its functional viability in the recipient animal was ensured by its prior binding with ethylenemaleic anhydride, thus shifting its pH activity curve towards the alkaline range. Rats implanted with dialysis membrane capsules containing such immobilized oxalate oxidase in their peritoneal cavities effectively metabolized intraperitoneally injected [14C]oxalate as well as its precursor [14C]glyoxalate. The implantation of capsules containing coentrapped multienzyme preparations of oxalate oxidase, catalase and peroxidase led to a further degradation of administered [14C]oxalate in rats.
Suspension Flame Spray Construction of Polyimide-Copper Layers for Marine Antifouling Applications
NASA Astrophysics Data System (ADS)
Liu, Yi; Xu, Xiaomin; Suo, Xinkun; Gong, Yongfeng; Li, Hua
2018-01-01
Individual capsule-like polyimide splats have been fabricated by suspension flame spray, and the polyimide splat exhibits hollow structure with an inner pore and a tiny hole on its top surface. Enwrapping of 200-1000-nm copper particles inside the splats is accomplished during the deposition for constrained release of copper for antifouling performances. Antifouling testing of the coatings by 24-h exposure to Escherichia coli-containing artificial seawater shows that the Cu-doped splat already prohibits effectively attachment of the bacteria. The prohibited adhesion of bacteria obviously impedes formation and further development of bacterial biofilm. This capsulated splat with releasing and loading of copper biocides results in dual-functional structures bearing both release-killing and contact-killing mechanisms. The suspension flame spray route and the encapsulated structure of the polyimide-Cu coatings would open a new window for designing and constructing marine antifouling layers for long-term applications.
2012-09-20
CAPE CANAVERAL, Fla. - NASA's Johnson Space Center Aerospace Engineer Jeff Hagen, left, and engineering intern Emmanuel Nyangweso attach rotors to the top of a model capsule ahead of tests inside the Vehicle Assembly Building at NASA's Kennedy Space Center in Florida. The design would give a capsule the stability and control of a helicopter, but would not be powered. Instead, the wind passing over the rotors as the capsule descends would make the blades turn, a process called auto-rotation. The intent is to give real spacecraft a soft landing with enough control that they could touch down anywhere in the world, whether it be a runway or parking lot. In other words, wherever a helicopter could land, a spacecraft could land, too. Photo credit: NASA/Kim Shiflett
2012-07-02
CAPE CANAVERAL, Fla. – U.S. Senator Bill Nelson, center, talks to the media in Kennedy Space Center's Operations and Checkout Building high bay following an event marking the arrival in Florida of NASA's first space-bound Orion capsule, behind him. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. The capsule was shipped to Kennedy from NASA's Michoud Assembly Facility in New Orleans where the crew module pressure vessel was built. The Orion production team will prepare the module for flight at Kennedy by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
2012-07-02
CAPE CANAVERAL, Fla. – Dan Dumbacher, NASA deputy associate administrator for Exploration Systems Development, addresses the audience assembled in Kennedy Space Center's Operations and Checkout Building high bay for an event marking the arrival of NASA's first space-bound Orion capsule in Florida. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. The capsule was shipped to Kennedy from NASA's Michoud Assembly Facility in New Orleans where the crew module pressure vessel was built. The Orion production team will prepare the module for flight at Kennedy by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
2012-07-02
CAPE CANAVERAL, Fla. – NASA astronaut Ricky Arnold addresses the audience assembled in Kennedy Space Center's Operations and Checkout Building high bay for an event marking the arrival of NASA's first space-bound Orion capsule in Florida. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. The capsule was shipped to Kennedy from NASA's Michoud Assembly Facility in New Orleans where the crew module pressure vessel was built. The Orion production team will prepare the module for flight at Kennedy by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett
2012-07-02
CAPE CANAVERAL, Fla. – NASA Kennedy Space Center Director Robert Cabana addresses the audience assembled in Kennedy's Operations and Checkout Building high bay for an event marking the arrival of NASA's first space-bound Orion capsule in Florida. Slated for Exploration Flight Test-1, an uncrewed mission planned for 2014, the capsule will travel farther into space than any human spacecraft has gone in more than 40 years. The capsule was shipped to Kennedy from NASA's Michoud Assembly Facility in New Orleans where the crew module pressure vessel was built. The Orion production team will prepare the module for flight at Kennedy by installing heat-shielding thermal protection systems, avionics and other subsystems. For more information, visit http://www.nasa.gov/orion. Photo credit: NASA/Kim Shiflett