  1. Gas-phase optical fiber photocatalytic reactors for indoor air application: a preliminary study on performance indicators

    NASA Astrophysics Data System (ADS)

    Palmiste, Ü.; Voll, H.

    2017-10-01

    The development of advanced air cleaning technologies aims to reduce building energy consumption by reduction of outdoor air flow rates while keeping the indoor air quality at an acceptable level by air cleaning. Photocatalytic oxidation is an emerging technology for gas-phase air cleaning that can be applied in a standalone unit or a subsystem of a building mechanical ventilation system. Quantitative information on photocatalytic reactor performance is required to evaluate the technical and economic viability of the advanced air cleaning by PCO technology as an energy conservation measure in a building air conditioning system. Photocatalytic reactors applying optical fibers as light guide or photocatalyst coating support have been reported as an approach to address the current light utilization problems and thus, improve the overall efficiency. The aim of the paper is to present a preliminary evaluation on continuous flow optical fiber photocatalytic reactors based on performance indicators commonly applied for air cleaners. Based on experimental data, monolith-type optical fiber reactor performance surpasses annular-type optical fiber reactors in single-pass removal efficiency, clean air delivery rate and operating cost efficiency.

  2. Clean Air Excellence Awards

    EPA Pesticide Factsheets

    These non-monetary awards honor sustainable efforts toward pollutant emissions reduction from innovators in clean air technology, community action and outreach, policy development, and transportation efficiency.

  3. Clean Air Excellence Award Recipients

    EPA Pesticide Factsheets

    Recipients are organized by award category within each year: Clean Air Technology, Community Action, Education/Outreach, Regulatory/Policy Innovations, Transportation Efficiency Innovations, Thomas W. Zosel individual, and Gregg Cooke Visionary Program.

  4. Air powder abrasive treatment as an implant surface cleaning method: a literature review.

    PubMed

    Tastepe, Ceylin S; van Waas, Rien; Liu, Yuelian; Wismeijer, Daniel

    2012-01-01

    To evaluate the air powder abrasive treatment as an implant surface cleaning method for peri-implantitis based on the existing literature. A PubMed search was conducted to find articles that reported on air powder abrasive treatment as an implant surface cleaning method for peri-implantitis. The studies evaluated cleaning efficiency and surface change as a result of the method. Furthermore, cell response toward the air powder abrasive-treated discs, reosseointegration, and clinical outcome after treatment is also reported. The PubMed search resulted in 27 articles meeting the inclusion criteria. In vitro cleaning efficiency of the method is reported to be high. The method resulted in minor surface changes on titanium specimens. Although the air powder abrasive-treated specimens showed sufficient levels of cell attachment and cell viability, the cell response decreased compared with sterile discs. Considerable reosseointegration between 39% and 46% and improved clinical parameters were reported after treatment when applied in combination with surgical treatment. The results of the treatment are influenced by the powder type used, the application time, and whether powder was applied surgically or nonsurgically. The in vivo data on air powder abrasive treatment as an implant surface cleaning method is not sufficient to draw definitive conclusions. However, in vitro results allow the clinician to consider the method as a promising option for implant surface cleaning in peri-implantitis treatment.

  5. ENVIRONMENTAL TECHNOLOGY VERIFICATION--GENERIC VERIFICATION PROTOCOL FOR BIOLOGICAL AND AEROSOL TESTING OF GENERAL VENTILATION AIR CLEANERS

    EPA Science Inventory

    Under EPA's Environmental Technology Verification Program, Research Triangle Institute (RTI) will operate the Air Pollution Control Technology Center to verify the filtration efficiency and bioaerosol inactivation efficiency of heating, ventilation and air conditioning air cleane...

  6. Performance of ultraviolet photocatalytic oxidation for indoor air cleaning applications.

    PubMed

    Hodgson, A T; Destaillats, H; Sullivan, D P; Fisk, W J

    2007-08-01

    Ultraviolet photocatalytic oxidation (UVPCO) systems for removal of volatile organic compounds (VOCs) from air are being considered for use in office buildings. Here, we report an experimental evaluation of a UVPCO device with tungsten oxide modified titanium dioxide (TiO2) as the photocatalyst. The device was challenged with complex VOC mixtures. One mixture contained 27 VOCs characteristic of office buildings and another comprised 10 VOCs emitted by cleaning products, in both cases at realistic concentrations (low ppb range). VOC conversion efficiencies varied widely, usually exceeded 20%, and were as high as approximately 80% at about 0.03 s residence time. Conversion efficiency generally diminished with increased airflow rate, and followed the order: alcohols and glycol ethers > aldehydes, ketones, and terpene hydrocarbons > aromatic and alkane hydrocarbons > halogenated aliphatic hydrocarbons. Conversion efficiencies correlated with the Henry's law constant more closely than with other physicochemical parameters. An empirical model based on the Henry's law constant and the gas-phase reaction rate with hydroxyl radical provided reasonable estimates of pseudo-first order photocatalytic reaction rates. Formaldehyde, acetaldehyde, acetone, formic acid and acetic acid were produced by the device due to incomplete mineralization of common VOCs. Formaldehyde outlet/inlet concentration ratios were in the range 1.9-7.2. Implementation of air cleaning technologies for both VOCs and particles in office buildings may improve indoor air quality, or enable indoor air quality levels to be maintained with reduced outdoor air supply and concomitant energy savings. One promising air cleaning technology is ultraviolet photocatalytic oxidation (UVPCO) air cleaning. For the prototype device evaluated here with realistic mixtures of VOCs, conversion efficiencies typically exceeded the minimum required to counteract predicted VOC concentration increases from a 50% reduction in ventilation. However, the device resulted in the net generation of formaldehyde and acetaldehyde from the partial oxidation of ubiquitous VOCs. Further development of the technology is needed to eliminate these hazardous air pollutants before such a UVPCO device can be deployed in buildings.

  7. Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems.

    PubMed

    Macintosh, David L; Myatt, Theodore A; Ludwig, Jerry F; Baker, Brian J; Suh, Helen H; Spengler, John D

    2008-11-01

    A novel method for determining whole house particle removal and clean air delivery rates attributable to central and portable ventilation/air cleaning systems is described. The method is used to characterize total and air-cleaner-specific particle removal rates during operation of four in-duct air cleaners and two portable air-cleaning devices in a fully instrumented test home. Operation of in-duct and portable air cleaners typically increased particle removal rates over the baseline rates determined in the absence of operating a central fan or an indoor air cleaner. Removal rates of 0.3- to 0.5-microm particles ranged from 1.5 hr(-1) during operation of an in-duct, 5-in. pleated media filter to 7.2 hr(-1) for an in-duct electrostatic air cleaner in comparison to a baseline rate of 0 hr(-1) when the air handler was operating without a filter. Removal rates for total particulate matter less than 2.5 microm in aerodynamic diameter (PM2.5) mass concentrations were 0.5 hr(-1) under baseline conditions, 0.5 hr(-1) during operation of three portable ionic air cleaners, 1 hr(-1) for an in-duct 1-in. media filter, 2.4 hr(-1) for a single high-efficiency particle arrestance (HEPA) portable air cleaner, 4.6 hr(-1) for an in-duct 5-in. media filter, 4.7 hr(-1) during operation of five portable HEPA filters, 6.1 hr(-1) for a conventional in-duct electronic air cleaner, and 7.5 hr(-1) for a high efficiency in-duct electrostatic air cleaner. Corresponding whole house clean air delivery rates for PM2.5 attributable to the air cleaner independent of losses within the central ventilation system ranged from 2 m3/min for the conventional media filter to 32 m3/min for the high efficiency in-duct electrostatic device. Except for the portable ionic air cleaner, the devices considered here increased particle removal indoors over baseline deposition rates.

  8. An innovative permanent total enclosure for blast cleaning and painting ships in drydock

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garland, C.; Lukey, M.

    1997-12-31

    This paper describes a new innovative Permanent Total Enclosure, or CAPE system, which encloses and captures emissions from blast cleaning and painting ship hulls in drydock. A description of the modular enclosure towers with unique seals is shown with several figures. The support barge with its environmental control equipment which includes a dust collector, VOC thermal oxidizer, dehumidifier, boiler, heating coils, air flow fans and, system controls is also described. Data measurements from the first two applications rate this system at 100 percent capture efficiency, 99 percent VOC destruction efficiency and 99.9 percent dust collection efficiency. Ships can be blastmore » cleaned and painted using noncompliant paints and meet all state and federal standards for air emissions.« less

  9. Evaluation of various activated carbons for air cleaning - Towards design of immune and sustainable buildings

    NASA Astrophysics Data System (ADS)

    Haghighat, Fariborz; Lee, Chang-Seo; Pant, Bhuvan; Bolourani, Golnoush; Lakdawala, Ness; Bastani, Arash

    There are increased demands for security, sustainability and indoor air quality in today's building design, construction, operation and maintenance. Installation of air cleaning systems can improve the indoor air quality by reducing the air pollution levels, and enhance the building security against sudden release of chemical and/or biological agents. At the same time, air cleaning techniques may reduce the building energy consumption by reducing the outdoor air supply rate, hence lowering the needs for conditioning of outdoor air. While the air filtration of particulate matter is well standardized, the standards against which the performance of air cleaning for gaseous contaminants is measured or classified are still under development. This study examined the performance of various granular activated carbons (GACs) for the removal of volatile organic compounds (VOCs) from mechanically ventilated buildings. Eight different GACs (three virgin and five impregnated) were tested against toluene using a dynamic test system. The virgin GACs showed better performance than impregnated ones, the percentage and the type of impregnation affected the removal efficiencies. Tests were also conducted with selected GACs against toluene, cyclohexane and ethyl acetate at relative humidity (RH) values of 30%, 50% and 70%. The effect of humidity was dependant on the VOC used. Both for toluene and cyclohexane, the removal efficiency decreased as RH increased. However, higher humidity showed a positive impact on the removal of ethyl acetate.

  10. Major factors affecting in situ biodegradation rates of jet-fuel during large-scale biosparging project in sedimentary bedrock.

    PubMed

    Machackova, Jirina; Wittlingerova, Zdena; Vlk, Kvetoslav; Zima, Jaroslav

    2012-01-01

    Biodegradation of petroleum hydrocarbons (TPH), mainly jet fuel, had taken place at the former Soviet Army air base in the Czech Republic. The remediation of large-scale petroleum contamination of soil and groundwater has provided valuable information about biosparging efficiency in the sandstone sedimentary bedrock. In 1997 petroleum contamination was found to be present in soil and groundwater across an area of 28 hectares, divided for the clean-up purpose into smaller clean-up fields (several hectares). The total estimated quantity of TPH released to the environment was about 7,000 metric tons. Biosparging was applied as an innovative clean-up technology at the site and was operated over a 10-year period (1997-2008). Importance of a variety of factors that affect bacterial activity in unsaturated and saturated zones was widely studied on the site and influence of natural and technological factors on clean-up efficiency in heavily contaminates areas of clean-up fields (initial contaminant mass 111-452 metric ton/ha) was evaluated. Long-term monitoring of the groundwater temperature has shown seasonal rises and falls of temperature which have caused a fluctuation in biodegradation activity during clean-up. By contrast, an overall rise of average groundwater temperature was observed in the clean-up fields, most probably as a result of the biological activity during the clean-up process. The significant rise of biodegradation rates, observed after air sparging intensification, and strong linear correlation between the air injection rates and biodegradation activities have shown that the air injection rate is the principal factor in biodegradation efficiency in heavily contaminated areas. It has a far more important role for achieving a biodegradation activity than the contamination content which appeared to have had only a slight effect after the removal of about 75% of initial contamination.

  11. Achieving 'excellent' indoor air quality in commercial offices equipped with air-handling unit--respirable suspended particulate.

    PubMed

    Lam, K S; Chan, F S; Fung, W Y; Lui, B S S; Lau, L W L

    2006-04-01

    A study was carried out to investigate the feasibility of achieving ultra low respirable suspended particulates (RSP) in commercial offices without major modification of existing ventilation systems by enhancing the particulates removal efficiency of existing central ventilation systems. Four types of filters which include pre-filters, cartridge filters, bag filters and high efficiency particulates air (HEPA) filters were tested in a commercial building in Causeway Bay. The results show that an RSP objective of <20 microg/m3 could be met by removing RSP from both the return air and outdoor air supply simultaneously. This level of performance is classed as 'excellent' by the Hong Kong Government, Environmental Protection Department. Filters with efficiency that exceed 80% placed both in the return air and outdoor air were sufficient to meet the objective. It is not necessary to install HEPA filters to achieve the 'excellent' class. The outdoor air filter has great influence on the steady state indoor RSP concentration while the effective cleaning rate is governed by the return air filter. Higher efficiency filters increased the static drop but the volume flow of the air fan was not affected significantly. The additional cost incurred was <5% of the existing operation cost. This paper reports a field study of RSP control for an indoor office environment. The results are directly applicable to building service engineering in the design of ventilation systems using air-handling units. Field observations indicated that indoor RSP in an office environment could be suppressed below 20 microg/m3 within 1 h by the simultaneous filtration of outdoor air and return air. Outdoor air filtration has a great influence on the steady state indoor concentration and return air filtration governs the cleaning rate. It is believed that the results of this study could be extended to the cleaning of other indoor pollutants such as volatile organic compounds.

  12. Introduction to Indoor Air Quality

    MedlinePlus

    ... as conditions caused by outdoor impacts (such as climate change). Many reports and studies indicate that the following ... Air Duct Cleaning Asthma Health, Energy Efficiency and Climate Change Flood Cleanup IAQ at Home Indoor airPLUS Mold ...

  13. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M.

    1991-12-31

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protectionmore » Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.« less

  14. The Clean Air Act Amendments of 1990: Hazardous Air Pollutant Requirements and the DOE Clean Coal Technology Program

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Moskowitz, P.D.; DePhillips, M.; Fthenakis, V.M.

    1991-01-01

    The purpose of the US Department of Energy -- Office of Fossil Energy (DOE FE) Clean Coal Technology Program (CCTP) is to provide the US energy marketplace with advanced, efficient, and environmentally sound coal-based technologies. The design, construction, and operation of Clean Coal Technology Demonstration Projects (CCTDP) will generate data needed to make informed, confident decisions on the commercial readiness of these technologies. These data also will provide information needed to ensure a proactive response by DOE and its industrial partners to the establishment of new regulations or a reactive response to existing regulations promulgated by the US Environmental Protectionmore » Agency (EPA). The objectives of this paper are to: (1) Present a preliminary examination of the potential implications of the Clean Air Act Amendments (CAAA) -- Title 3 Hazardous Air Pollutant requirements to the commercialization of CCTDP; and (2) help define options available to DOE and its industrial partners to respond to this newly enacted Legislation.« less

  15. Air pollution control systems in WtE units: An overview

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vehlow, J., E-mail: juergen.vehlow@partner.kit.edu

    Highlights: • The paper describes in brief terms the development of gas cleaning in waste incineration. • The main technologies for pollutant removal are described including their basic mechanisms. • Their respective efficiencies and their application are discussed. • A cautious outlook regarding future developments is made. - Abstract: All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removalmore » of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made.« less

  16. A comparative study on laser induced shock cleaning of radioactive contaminants in air and water

    NASA Astrophysics Data System (ADS)

    Kumar, Aniruddha; Prasad, Manisha; Bhatt, R. B.; Behere, P. G.; Biswas, D. J.

    2018-03-01

    Efficient removal of Uranium-di-oxide (UO2) particulates from stainless steel surface was effected by Nd-YAG laser induced plasma shock waves in air as well as in water environment. The propagation velocity of the generated shock wave was measured by employing the photo-acoustic probe deflection method. Monitoring of the alpha activity of the sample with a ZnS (Ag) scintillation detector before and after the laser exposure allowed the estimation of decontamination efficiency defined as the percentage removal of the initial activity. Experiments were carried out to study the effect of laser pulse energy, number of laser exposures, orientation of the sample, the separation between the substrate surface and the onset point of the shock wave on the de-contamination efficiency. The most optimised cleaning was found to occur when the laser beam impinged normally on the sample that was immersed in water and placed at a distance of ∼0.7 mm from the laser focal spot. Analysis of the cleaned surface by optical microscopes established that laser induced shock cleaning in no way altered the surface property. The shock force generated in both air and water has been estimated theoretically and has been found to exceed the Van der Waal's binding force for spherical contaminant particulate.

  17. US-China Clean Energy Research Center on Building Energy Efficiency: Materials that Improve the Cost-Effectiveness of Air Barrier Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hun, Diana E.

    The US–China Clean Energy Research Center (CERC) was launched in 2009 by US Energy Secretary Steven Chu, Chinese Minister of Science and Technology Wan Gang, and Chinese National Energy Agency Administrator Zhang Guobao. This 5-year collaboration emerged from the fact that the United States and China are the world’s largest energy producers, energy consumers, and greenhouse gas emitters, and that their joint effort could have significant positive repercussions worldwide. CERC’s main goal is to develop and deploy clean energy technologies that will help both countries meet energy and climate challenges. Three consortia were established to address the most pressing energy-relatedmore » research areas: Advanced Coal Technology, Clean Vehicles, and Building Energy Efficiency (BEE). The project discussed in this report was part of the CERC-BEE consortia; its objective was to lower energy use in buildings by developing and evaluating technologies that improve the cost-effectiveness of air barrier systems for building envelopes.« less

  18. Can commonly-used fan-driven air cleaning technologies improve indoor air quality? A literature review

    NASA Astrophysics Data System (ADS)

    Zhang, Yinping; Mo, Jinhan; Li, Yuguo; Sundell, Jan; Wargocki, Pawel; Zhang, Jensen; Little, John C.; Corsi, Richard; Deng, Qihong; Leung, Michael H. K.; Fang, Lei; Chen, Wenhao; Li, Jinguang; Sun, Yuexia

    2011-08-01

    Air cleaning techniques have been applied worldwide with the goal of improving indoor air quality. The effectiveness of applying these techniques varies widely, and pollutant removal efficiency is usually determined in controlled laboratory environments which may not be realized in practice. Some air cleaners are largely ineffective, and some produce harmful by-products. To summarize what is known regarding the effectiveness of fan-driven air cleaning technologies, a state-of-the-art review of the scientific literature was undertaken by a multidisciplinary panel of experts from Europe, North America, and Asia with expertise in air cleaning, aerosol science, medicine, chemistry and ventilation. The effects on health were not examined. Over 26,000 articles were identified in major literature databases; 400 were selected as being relevant based on their titles and abstracts by the first two authors, who further reduced the number of articles to 160 based on the full texts. These articles were reviewed by the panel using predefined inclusion criteria during their first meeting. Additions were also made by the panel. Of these, 133 articles were finally selected for detailed review. Each article was assessed independently by two members of the panel and then judged by the entire panel during a consensus meeting. During this process 59 articles were deemed conclusive and their results were used for final reporting at their second meeting. The conclusions are that: (1) None of the reviewed technologies was able to effectively remove all indoor pollutants and many were found to generate undesirable by-products during operation. (2) Particle filtration and sorption of gaseous pollutants were among the most effective air cleaning technologies, but there is insufficient information regarding long-term performance and proper maintenance. (3) The existing data make it difficult to extract information such as Clean Air Delivery Rate (CADR), which represents a common benchmark for comparing the performance of different air cleaning technologies. (4) To compare and select suitable indoor air cleaning devices, a labeling system accounting for characteristics such as CADR, energy consumption, volume, harmful by-products, and life span is necessary. For that purpose, a standard test room and condition should be built and studied. (5) Although there is evidence that some air cleaning technologies improve indoor air quality, further research is needed before any of them can be confidently recommended for use in indoor environments.

  19. Nonequilibrium gas absorption in rotating permeable media

    NASA Astrophysics Data System (ADS)

    Baev, V. K.; Bazhaikin, A. N.

    2016-08-01

    The absorption of ammonia, sulfur dioxide, and carbon dioxide by water and aqueous solutions in rotating permeable media, a cellular porous disk, and a set of spaced-apart thin disks has been considered. The efficiency of cleaning air to remove these impurities is determined, and their anomalously high solubility (higher than equilibrium value) has been discovered. The results demonstrate the feasibility of designing cheap efficient rotor-type absorbers to clean gases of harmful impurities.

  20. Brushless Cleaning of Solar Panels and Windows

    NASA Technical Reports Server (NTRS)

    Schneider, H. W.

    1982-01-01

    Machine proposed for cleaning solar panels and reflectors uses multiple vortexes of air, solvent, and water to remove dust and dirt. Uses no brushes that might abrade solar surfaces and thereby reduce efficiency. Machine can be readily automated and can be used on curved surfaces such as aparbolic reflectors as well as on flat ones. Cleaning fluids are recycled, so that large quantities of water and solvent are not needed.

  1. Estimation of Qualitative and Quantitative Parameters of Air Cleaning by a Pulsed Corona Discharge Using Multicomponent Standard Mixtures

    NASA Astrophysics Data System (ADS)

    Filatov, I. E.; Uvarin, V. V.; Kuznetsov, D. L.

    2018-05-01

    The efficiency of removal of volatile organic impurities in air by a pulsed corona discharge is investigated using model mixtures. Based on the method of competing reactions, an approach to estimating the qualitative and quantitative parameters of the employed electrophysical technique is proposed. The concept of the "toluene coefficient" characterizing the relative reactivity of a component as compared to toluene is introduced. It is proposed that the energy efficiency of the electrophysical method be estimated using the concept of diversified yield of the removal process. Such an approach makes it possible to substantially intensify the determination of energy parameters of removal of impurities and can also serve as a criterion for estimating the effectiveness of various methods in which a nonequilibrium plasma is used for air cleaning from volatile impurities.

  2. Clean Air Act in California: The Reclaim Program. Hearing before the Subcommittee on Health and the Environment of the Committee on Energy and Commerce, House of Representatives, One Hundred Third Congress, First Session, October 4, 1993

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1994-01-01

    These hearings investigate the RECLAIM program in Southern California which would use market forces to reduce the emissions from large polluters. The program applies only to nitrogen oxides and sulfur dioxide. Questions exist about whether the long-term goals are realistic; fairness both from the standpoint of the emissions allocation and for the potential for packing pollution into minority and lower-income communities; and whether or not RECLAIM meets the requirements of the Clean Air Act. Representatives of several interested parties from California (including S. Coast Metal Coalition; S. Cal. Edison; Ca. Air resources Board; S. Coast Air Quality Management District; S.more » Ca. Gas) testify along with Director of the Center for Energy Efficiency and Renewable technologies; Western States Petroleum Ass., regulatory Flexibility Group; Coalition for Clean Air.« less

  3. Report: Clean Air Act Facility Evaluations Are Conducted, but Inaccurate Data Hinder EPA Oversight and Public Awareness

    EPA Pesticide Factsheets

    Report #16-P-0164, May 3, 2016. Accurate enforcement databases and updated CMS plans promote effective and efficient EPA oversight of compliance programs, and help to protect the public from harmful air pollutants.

  4. Rules, Roles, and Responsibilities in Transportation Planning and Air Quality: One State's View

    DOT National Transportation Integrated Search

    1999-01-01

    The Clean Air Act Amendments (CAAA) of 1990 and the Intermodal Surface : Transportation Efficiency Act (ISTEA) of 1991 are a pivotal moment in : transportation planning in the United States. In 1997 the U.S. Environmental : Protection Agency revised ...

  5. Air pollution control systems in WtE units: an overview.

    PubMed

    Vehlow, J

    2015-03-01

    All WtE (waste-to-energy) plants, based on combustion or other thermal processes, need an efficient gas cleaning for compliance with legislative air emission standards. The development of gas cleaning technologies started along with environment protection regulations in the late 1960s. Modern APC (air pollution control) systems comprise multiple stages for the removal of fly ashes, inorganic and organic gases, heavy metals, and dioxins from the flue gas. The main technologies and devices used for abatement of the various pollutants are described and their basic principles, their peculiarities, and their application are discussed. Few systems for cleaning of synthesis gas from waste gasification plants are included. Examples of APC designs in full scale plants are shown and cautious prospects for the future development of APC systems are made. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Substantiation of basic scheme of grain cleaning machine for preparation of agricultural crops seeds

    NASA Astrophysics Data System (ADS)

    Giyevskiy, A. M.; Orobinsky, V. I.; Tarasenko, A. P.; Chernyshov, A. V.; Kurilov, D. O.

    2018-03-01

    The article presents data on the feasibility of the concept of a high-efficiency seed cleaner with the consistent use of the air flow in aspiration and the multi-tier placement of the sorting grids in grating mills. As a result of modeling, the directions for further improvement of air-screen seed cleaning machines have been identified: an increase in the proportion of sorting grids in the mills up to 70 ... 80% and an increase in the speed of the air flow in the channel of the pre-filter cleaning up to 8.0 m / s. Experiments have established the competence of using mathematical modeling of airflow in the pneumatic system with the use of a finite-volume method for solving hydrodynamic equations for substantiating the basic parameters of the pneumatic system.

  7. Maintaining flexible pavements : the long term pavement performance experiment SPS-3 5-year data analysis

    DOT National Transportation Integrated Search

    1997-02-01

    This report focuses on the Clean Air Act (CAAA) and the State Air Quality Implementation Plan (SIP) and the need for conformity with transportation measures and policies. The Intermodal Surface Transportation Efficiency Act (ISTEA) has reinforced Fed...

  8. Aerobiology in the operating room and its implications for working standards.

    PubMed

    Friberg, B; Friberg, S

    2005-01-01

    Two novel operating room (OR) ventilation concepts, i.e. the upward displacement or thermal convection system and the exponential ultra-clean laminar air flow (LAF) designed to function without extra walls, were evaluated from a bacteriological point of view. The thermal convection system (17 air changes/h) was compared with conventional ventilation (16 air changes/h) with an air inlet at the ceiling and evacuation at floor level. The exponential LAF was compared with the vertical ultra-clean LAF and the horizontal ultra-clean LAF, both with extra side walls. The comparison was made using strictly standardized simulated operations and, except for the horizontal LAF, it was performed in the same OR where the type of ventilation was changed. In the different areas important for surgical asepsis, the thermal system resulted in a twofold to threefold increase in bacterial air and surface counts compared to the conventional system (statistical significance = p < 0.05-0.0001). The bacteriological efficiency of the exponential LAF was equal to the horizontal and vertical LAF units with extra walls in the OR, and all three systems easily fulfilled the criteria for ultra-clean air, i.e. bacteria-carrying particles < 10/m3. In the areas important for surgical asepsis the turbulent ventilation systems yielded highly significant correlation between air and surface contamination (p < 0.02-0.0006). No such correlation existed in the LAF systems.

  9. Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus

    DOEpatents

    Jody, Bassam; Daniels, Edward; Libera, Joseph A.

    1999-01-01

    A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam.

  10. Efficient continuous dryer for flexible polyurethane foam and cleaning apparatus

    DOEpatents

    Jody, B.; Daniels, E.; Libera, J.A.

    1999-03-16

    A method of cleaning polyurethane foams where the material is transported through a wash station while alternately soaking the polyurethane foam in an organic solvent and squeezing solvent from the polyurethane foam a number of times. Then the polyurethane foam is sent through a rinse or solvent transfer station for reducing the concentration of solvent in the foam. The rinsed polyurethane foam is sent to a drying station wherein the foam is repeatedly squeezed while being exposed to hot air to remove wet air from the foam. 4 figs.

  11. Improved Prediction Models For PCC Pavement Performance-Related Specifications, Volume I: Final Report

    DOT National Transportation Integrated Search

    1992-01-01

    This brochure summarizes the provisions of the Intermodal Surface Transportation Efficiency Act of 1991 (ISTEA) that can best help State and local officials as they work toward the air quality goals of the Clean Air Act Amendments of 1990 (CAAA). Thi...

  12. HEPA Help

    ERIC Educational Resources Information Center

    Rathey, Allen

    2006-01-01

    Poor indoor air quality in school facilities can detract from the health and productivity of students, teachers and other employees. Asthma--often triggered or aggravated by dust--is the No. 1 cause of chronic absenteeism in schools. Using vacuum cleaners equipped with high-efficiency particulate air (HEPA) filters to clean education institutions…

  13. Boiler MACT Technical Assistance (Fact Sheet)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2012-03-01

    Fact sheet describing the changes to Environmental Protection Act process standards. The DOE will offer technical assistance to ensure that major sources burning coal and oil have information on cost-effective, clean energy strategies for compliance, and to promote cleaner, more efficient boiler burning to cut harmful pollution and reduce operational costs. The U.S. Environmental Protection Agency (EPA) is expected to finalize the reconsideration process for its Clean Air Act pollution standards National Emissions Standards for Hazardous Air Pollutants for Major Sources: Industrial, Commercial, and Institutional Boilers and Process Heaters (known as Boiler Maximum Achievable Control Technology (MACT)), in Spring 2012.more » This rule applies to large and small boilers in a wide range of industrial facilities and institutions. The U.S. Department of Energy (DOE) will offer technical assistance to ensure that major sources burning coal or oil have information on cost-effective clean energy strategies for compliance, including combined heat and power, and to promote cleaner, more efficient boilers to cut harmful pollution and reduce operational costs.« less

  14. Wavelet imaging cleaning method for atmospheric Cherenkov telescopes

    NASA Astrophysics Data System (ADS)

    Lessard, R. W.; Cayón, L.; Sembroski, G. H.; Gaidos, J. A.

    2002-07-01

    We present a new method of image cleaning for imaging atmospheric Cherenkov telescopes. The method is based on the utilization of wavelets to identify noise pixels in images of gamma-ray and hadronic induced air showers. This method selects more signal pixels with Cherenkov photons than traditional image processing techniques. In addition, the method is equally efficient at rejecting pixels with noise alone. The inclusion of more signal pixels in an image of an air shower allows for a more accurate reconstruction, especially at lower gamma-ray energies that produce low levels of light. We present the results of Monte Carlo simulations of gamma-ray and hadronic air showers which show improved angular resolution using this cleaning procedure. Data from the Whipple Observatory's 10-m telescope are utilized to show the efficacy of the method for extracting a gamma-ray signal from the background of hadronic generated images.

  15. Automated Array Assembly Task In-depth Study of Silicon Wafer Surface Texturizing

    NASA Technical Reports Server (NTRS)

    Jones, G. T.; Chitre, S.; Rhee, S. S.; Allison, K. L.

    1979-01-01

    A low cost wafer surface texturizing process was studied. An investigation of low cost cleaning operations to clean residual wax and organics from the surface of silicon wafers was made. The feasibility of replacing dry nitrogen with clean dry air for drying silicon wafers was examined. The two stage texturizing process was studied for the purpose of characterizing relevant parameters in large volume applications. The effect of gettering solar cells on photovoltaic energy conversion efficiency is described.

  16. Removal of biofilm from contact lens storage cases.

    PubMed

    Wu, Yvonne T; Zhu, Hua; Willcox, Mark; Stapleton, Fiona

    2010-12-01

    Lens case hygiene practices are important in maintaining safe contact lens wear. However, the effectiveness of various lens case cleaning practices have not been evaluated and compared. This in vitro study aimed to evaluate and compare the efficacy of cleaning practices that are most commonly carried out by lens wearers and recommended by practitioners. Pseudomonas aeruginosa 122, Serratia marcescens ATCC 13880, and Staphylococcus aureus ATCC 6538 were the challenge bacteria for biofilm formation on unused lens cases from two different manufacturers. After establishment of the biofilm, each lens case was subjected to one of the six cleaning regimens: "rinsed," "rubbed and rinsed," "air-dried," "soaked in a multipurpose contact lens solution," "tissue-wiped," and "lids recapped." The level of residual biofilm was quantified at the end of each cleaning regimen. The efficacy of each cleaning regimen was then compared. Mechanical rubbing and wiping of lens cases were the most effective cleaning regimen tested in reducing biofilm. Soaking lenses in disinfecting solution for 6 hours removed the majority of biofilm from lens cases. Rinsing lens cases alone provided only minimal efficacy in reducing biofilm. Air-drying or recapping the cases with the lid without any other additional cleaning methods were the least efficient at removing biofilm. Based on this study, digital rubbing and rinsing and/or wiping the lens cases with tissue is recommended. Air-drying or recapping the lens case lids after use without any additional cleaning methods should be discouraged with non-antimicrobial lens cases.

  17. [Reduction of livestock-associated methicillin-resistant staphylococcus aureus (LA-MRSA) in the exhaust air of two piggeries by a bio-trickling filter and a biological three-step air cleaning system].

    PubMed

    Clauss, Marcus; Schulz, Jochen; Stratmann-Selke, Janin; Decius, Maja; Hartung, Jörg

    2013-01-01

    "Livestock-associated" Methicillin-resistent Staphylococcus aureus (LA-MRSA) are frequently found in the air of piggeries, are emitted into the ambient air of the piggeries and may also drift into residential areas or surrounding animal husbandries.. In order to reduce emissions from animal houses such as odour, gases and dust different biological air cleaning systems are commercially available. In this study the retention efficiencies for the culturable LA-MRSA of a bio-trickling filter and a combined three step system, both installed at two different piggeries, were investigated. Raw gas concentrations for LA-MRSA of 2.1 x 10(2) cfu/m3 (biotrickling filter) and 3.9 x 10(2) cfu/m3 (three step system) were found. The clean gas concentrations were in each case approximately one power of ten lower. Both systems were able to reduce the number of investigated bacteria in the air of piggeries on average about 90%. The investigated systems can contribute to protect nearby residents. However, considerable fluctuations of the emissions can occur.

  18. Ceramic membrane defouling (cleaning) by air Nano Bubbles.

    PubMed

    Ghadimkhani, Aliasghar; Zhang, Wen; Marhaba, Taha

    2016-03-01

    Ceramic membranes are among the most promising technologies for membrane applications, owing to their excellent resistance to mechanical, chemical, and thermal stresses. However, membrane fouling is still an issue that hampers the applications at large scales. Air Nano Bubbles (NBs), due to high mass transfer efficiency, could potentially prevent fouling of ceramic membrane filtration processes. In this study, bench and pilot scale ceramic membrane filtration was performed with air NBs to resist fouling. To simulate fouling, humic acid, as an organic foulant, was applied to the membrane flat sheet surface. Complete membrane clogging was achieved in less than 6 h. Membrane defouling (cleaning) was performed by directly feeding of air NBs to the membrane cells. The surface of the ceramic membrane was superbly cleaned by air NBs, as revealed by atomic force microscope (AFM) images before and after the treatment. The permeate flux recovered to its initial level (e.g., 26.7 × 10(-9) m(3)/m(2)/s at applied pressure of 275.8 kPa), which indicated that NBs successfully unclogged the pores of the membrane. The integrated ceramic membrane and air NBs system holds potential as an innovative sustainable technology. Copyright © 2015 Elsevier Ltd. All rights reserved.

  19. An investigation of the leaf retention capacity, efficiency and mechanism for atmospheric particulate matter of five greening tree species in Beijing, China.

    PubMed

    Liu, Jinqiang; Cao, Zhiguo; Zou, Songyan; Liu, Huanhuan; Hai, Xiao; Wang, Shihua; Duan, Jie; Xi, Benye; Yan, Guangxuan; Zhang, Shaowei; Jia, Zhongkui

    2018-03-01

    Urban trees have the potential to reduce air pollution, but the retention capacity and efficiency of different tree species for atmospheric particulate matter (PM) accumulation and the underlying mechanism hasn't been well understood. To select tree species with high air purification abilities, the supplementing ultrasonic cleaning (UC) procedure was first introduced into the conventional leaf cleaning methods [single water cleaning (WC) or plus brush cleaning (BC)] for eluting the leaf-retained PM. Further updates to the methodology were applied to investigate the retention capacity, efficiency, and mechanism for PM of five typical greening tree species in Beijing, China. Meanwhile, the particle size distribution of PM on the leaves, the PM retention efficiencies of easily removable (ERP), difficult-to-remove (DRP) and totally removable (TRP) particles on the leaf (AE leaf ), and the individual tree scales were estimated. The experimental leaf samples were collected from trees with similar sizes 4 (SDR) and 14days (LDR) after rainfall. When the leaves were cleaned by WC+BC, there was, on average, 29%-46% of the PM remaining on the leaves of different species, which could be removed almost completely if UC was supplemented. From SDR to LDR, the mass of the leaf-retained PM increased greatly, and the particle size distribution changed markedly for all species except for Sophorajaponica. Pinus tabuliformis retains particles with the largest average diameter (34.2μm), followed by Ginkgo biloba (20.5μm), Sabina chinensis (16.4μm), Salix babylonica (16.0μm), and S. japonica (13.1μm). S. japonica and S. chinensis had the highest AE leaf to retain the TRP and ERP of both PM 1 and PM 1-2.5 , respectively. Conversely, S. babylonica and P. tabuliformis could retain both TRP and ERP of PM 2.5-5 and PM 5-10 , and PM >10 and TSP with the highest AE leaf , respectively. In conclusion, our results could be useful in selecting greening tree species with high air purification abilities. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. Environmental Technology Verification: Biological Inactivation Efficiency by HVAC In-Duct Ultraviolet Light Systems--American Ultraviolet Corporation, DC24-6-120 [EPA600etv08005

    EPA Science Inventory

    The Air Pollution Control Technology Verification Center (APCT Center) is operated by RTI International (RTI), in cooperation with EPA's National Risk Management Research Laboratory. The APCT Center conducts verifications of technologies that clean air in ventilation systems, inc...

  1. Summary of efficiency testing of standard and high-capacity high-efficiency particulate air filters subjected to simulated tornado depressurization and explosive shock waves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, P.R.; Gregory, W.S.

    1985-04-01

    Pressure transients in nuclear facility air cleaning systems can originate from natural phenomena such as tornadoes or from accident-induced explosive blast waves. This study was concerned with the effective efficiency of high-efficiency particulate air (HEPA) filters during pressure surges resulting from simulated tornado and explosion transients. The primary objective of the study was to examine filter efficiencies at pressure levels below the point of structural failure. Both standard and high-capacity 0.61-m by 0.61-m HEPA filters were evaluated, as were several 0.2-m by 0.2-m HEPA filters. For a particular manufacturer, the material release when subjected to tornado transients is the samemore » (per unit area) for both the 0.2-m by 0.2-m and the 0.61-m by 0.61-m filters. For tornado transients, the material release was on the order of micrograms per square meter. When subjecting clean HEPA filters to simulated tornado transients with aerosol entrained in the pressure pulse, all filters tested showed a degradation of filter efficiency. For explosive transients, the material release from preloaded high-capacity filters was as much as 340 g. When preloaded high-capacity filters were subjected to shock waves approximately 50% of the structural limit level, 1 to 2 mg of particulate was released.« less

  2. Ventilating Air-Conditioner

    NASA Technical Reports Server (NTRS)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  3. Impacts of household coal and biomass combustion on indoor and ambient air quality in China: Current status and implication.

    PubMed

    Li, Qing; Jiang, Jingkun; Wang, Shuxiao; Rumchev, Krassi; Mead-Hunter, Ryan; Morawska, Lidia; Hao, Jiming

    2017-01-15

    This review briefly introduces current status of indoor and ambient air pollution originating from household coal and biomass combustion in mainland China. Owing to low combustion efficiency, emissions of CO, PM 2.5 , black carbon (BC), and polycyclic aromatic hydrocarbons have significant adverse consequences for indoor and ambient air qualities, resulting in relative contributions of more than one-third in all anthropogenic emissions. Their contributions are higher in less economically developed regions, such as Guizhou (61% PM 2.5 , 80% BC), than that in more developed regions, such as Shanghai (4% PM 2.5 , 17% BC). Chimneys can reduce ~80% indoor PM 2.5 level when burning dirty solid fuels, such as plant materials. Due to spending more time near stoves, housewives suffer much more (~2 times) PM 2.5 than the adult men, especially in winter in northern China (~4 times). Improvement of stove combustion/thermal efficiencies and solid fuel quality are the two essential methods to reduce pollutant emissions. PM 2.5 and BC emission factors (EFs) have been identified to increase with volatile matter content in traditional stove combustion. EFs of dirty fuels are two orders higher than that of clean ones. Switching to clean ones, such as semi-coke briquette, was identified to be a feasible path for reducing >90% PM 2.5 and BC emissions. Otherwise, improvement of thermal and combustion efficiencies by using under-fire technology can reduce ~50% CO 2 , 87% NH 3 , and 80% PM 2.5 and BC emissions regardless of volatile matter content in solid fuel. However, there are still some knowledge gaps, such as, inventory for the temporal impact of household combustion on air quality, statistic data for deployed clean solid fuels and advanced stoves, and the effect of socioeconomic development. Additionally, further technology research for reducing air pollution emissions is urgently needed, especially low cost and clean stove when burning any type of solid fuel. Furthermore, emission-abatement oriented policy should base on sound scientific evidence to significantly reduce pollutant emissions. Copyright © 2016 Elsevier B.V. All rights reserved.

  4. The Energy Implications of Air-Side Fouling in Constant Air Volume HVAC Systems

    NASA Astrophysics Data System (ADS)

    Wilson, Eric J. H.

    2011-12-01

    This thesis examines the effect of air-side fouling on the energy consumption of constant air volume (CAV) heating, ventilating, and air conditioning (HVAC) systems in residential and small commercial buildings. There is a particular focus on evaluating the potential energy savings that may result from the remediation of such fouling from coils, filters, and other air system components. A computer model was constructed to simulate the behavior of a building and its duct system under various levels of fouling. The model was verified through laboratory and field testing and then used to run parametric simulations to examine the range of energy impacts for various climates and duct system characteristics. A sensitivity analysis was conducted to determine the impact of parameters like duct insulation, duct leakage, duct location, and duct design on savings potential. Duct system pressures, temperatures, and energy consumption for two houses were monitored for one month. The houses' duct systems, which were both in conditioned space, were given a full cleaning, and were then monitored for another month. The flow rates at the houses improved by 10% and 6%. The improvements were primarily due to installing a new filter, as both houses had only light coil fouling. The results indicate that there was negligible change in heating energy efficiency due to the system cleaning. The parametric simulation results are in agreement with the field experiment: for systems in all eight climates, with flowrates degraded by 20% or less, if ducts are located within the thermal zone, HVAC source energy savings from cleaning are negligible or even slightly negative. However, if ducts are outside the thermal zone, savings are in the 1 to 5% range. For systems with flowrates degraded by 40%, if ducts are within the thermal zone, savings from cleaning occurs only for air conditioning energy, up to 8% in climates like Miami, FL. If ducts are outside the thermal zone, savings occurs with both heating and cooling energy, and ranges from 7% in Los Angeles, CA to 13% in Fairbanks, AK. These results assume a leaky and uninsulated duct system. The potential for savings from cleaning decreases if duct insulation is in place or sealing has been performed. The potential for energy savings is directly related to the distribution system's thermal efficiency, with air conditioner performance also playing a minor role. Results for small commercial buildings with constant air volume HVAC systems and leaky and uninsulated duct systems span a wider range: from -12% in Miami, FL to 30% in Minneapolis, MN. However, for improved ducts or ducts in the conditioned space, small commercial HVAC source energy savings is always negative (down to -17%) for flowrates degradation in the 0--40% range. The sensitivity of these results to duct characteristics (location, leakage, and insulation) and the after-cleaning flowrate, as it varies from an ideal flowrate, was also evaluated. Energy savings can reach up to 80% for some scenarios where clean airflow is severely restricted down to 20% of ideal by poor duct layout or other obstructions not removable by cleaning. In addition, a simplified spreadsheet tool was developed for technicians to use in the field to estimate potential savings resulting from a system cleaning. Measuring the temperature rise across the furnace was found to give less uncertainty than measuring the pressure rise and assuming a fan curve. Despite the uncertainty, the tool can give a general idea of the range of savings possible under various conditions.

  5. Expert systems for crash data collection

    DOT National Transportation Integrated Search

    1995-08-01

    The Federal Highway Administration (FHWA) recognizes that many metropolitan areas are struggling with how to respond adequately to the 1990 Clean Air Act Amendments (CAAA) and the 1991 Intermodal Surface Transportation Efficiency Act (ISTEA), particu...

  6. Nuclear air cleaning: the need for a change in emphasis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carbaugh, E.H.

    1982-11-01

    The nuclear industry now has over 35 years of experience in nuclear air cleaning. This experience covers technology development, system design, operations, and maintenance. Much of the past experience has been directed towards technology development with particular emphasis on high efficiency particulate air (HEPA) filters. Implementation of this technology has lagged its development by a number of years. A recent study examines the cause and frequencies of HEPA filter changeouts and failures. These data lead to a conclusion that a shift in emphasis from technology development to the training of personnel and the designing and maintaining of such systems ismore » needed. Some highlights of the data and a discussion of topics which should be addressed in training will be presented.« less

  7. 75 FR 72956 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Clean Air Interstate Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-29

    ... ``biomass'' was added so that cogeneration units could exclude biomass energy input in efficiency... the cogeneration unit definition to exclude energy input from biomass. At 326 IAC 24-1-2 (8), 326 IAC... ``Biomass'' in Reference to ``Cogeneration Unit'' H. The State's Complete CAIR Regulations I. NO X Reduction...

  8. ‘GREENER’ SURFACTANTS FROM BIO-BASED WASTE AS EFFICIENT ALTERNATIVES TO NONYLPHENOL ETHOXYLATES

    EPA Science Inventory

    All bio-based surfactants synthesized over the course of the project will be tested for their ability to lower the surface tension at the air-water interface using a Du Nüoy ring tensiometer. The cleaning efficiency of the surfactants will be tested at the Toxics Use Reduc...

  9. The Oregon modeling improvement program : an overview

    DOT National Transportation Integrated Search

    2002-06-01

    In the early 1990s, the federal government was interested in integrating land use, transportation, economics and environmental issues. The Federal Intermodal Surface Transportation Efficiency Act (ISTEA) and the 1990 Clean Air Act Amendments (CAAA) w...

  10. Developing a Global Green Freight Action Plan

    EPA Pesticide Factsheets

    This Climate and Clean Air Coalition (CCAC) presentation gives an overview of the Global Green Freight Action Plan to improve the energy efficiency and environmental performance of freight operations worldwide along with developing an action plan.

  11. 77 FR 21098 - Notice of Meeting of the Environmental Financial Advisory Board (EFAB), and Transit-Oriented...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-09

    ... discussed include: clean air technology; tribal environmental programs; transit-oriented development; energy efficiency; green infrastructure; and drinking water pricing. The meeting is open to the public, however...

  12. Revealing driving factors of China's PM2.5 pollution

    NASA Astrophysics Data System (ADS)

    Zheng, Y.; Zhao, H.; Zhang, Q.; Geng, G.; Tong, D.; Peng, L.; He, K.

    2017-12-01

    China's rapid economic development and intensive energy consumption are deteriorating the air quality significantly. Understanding the key driving factors behind China's growing emissions of air pollutants and the accompanying PM2.5 pollution is critical for the development of China's clean air policies and also provides insight into how other emerging economies may develop a clear sky future. Here we reveal the socioeconomic drivers of the variations of China's PM2.5 concentrations during 2002-2012 by using an interdisciplinary framework that integrates an emission inventory model, an index decomposition analysis model, and a regional air quality model. The decomposition results demostrate that the improvements in emission efficiency and energy efficiency failed to offset the increased emissions of both primary PM2.5 and gaseous PM2.5 precursors (including SO2 NOx, and volatile organic compounds) triggered by the surging economic growth during 2002-2012. During the same time, the effects of energy structure, production structure and population growth were relatively less significant to all pollutants, which indicates the potential of large emission abatements through energy structure and production structure adjustment. Sensitivity simulations by the air quality model based on the provincial decomposition results also show that the economic growth have outpaced efficiency improvements in the increments of PM2.5 concentrations during the study years. As China continues to develop rapidly, future policies should promote further improvements in efficiency and accelerate the adjustments toward clean energy and production structures, which are critical for reducing China's emissions and alleviating the severe PM2.5 pollution.

  13. Better kitchens and toilets: both needed for better health.

    PubMed

    Ravindra, Khaiwal; Smith, Kirk R

    2018-05-01

    Both poor water, sanitation, hygiene (WaSH) and household air pollution (HAP) adversely affect the health of millions of people each year around the globe and specifically in developing countries. The objective of current work is to highlight the importance of HAP in parallel to WaSH for decision making to achieve better health specially in developing countries. There are examples, where developing countries are strengthening efforts to tackle the issue of poor water and sanitation such as 'Clean India Mission' was recently launched by the Government of India. However, there is lack of actions to address the issue related to HAP-to extend the coverage of clean fuel, efficient stoves and ventilated kitchens to the deprived population under the 'Clean India Mission'. Most of the rural household and urban slums in developing countries have only a single room, where people cook and sleep. This leads them to exposure to toxic HAP, which can be minimized by developing country specific indoor air quality guidelines and action framework. Hence, there should be policies to provide them not only the subsidy for clean fuel but also to build properly ventilated kitchens along with the promotion of clean toilets and water supplies. There is a need to strengthen global efforts, to jointly address the challenges associated with the risks related to WaSH and HAP in order to efficiently reduce the global burden of disease. Further, this will also help to timely attain the sustainable development goals for better health and environment.

  14. Ghana randomized air pollution and health study (GRAPHS): study protocol for a randomized controlled trial.

    PubMed

    Jack, Darby W; Asante, Kwaku Poku; Wylie, Blair J; Chillrud, Steve N; Whyatt, Robin M; Ae-Ngibise, Kenneth A; Quinn, Ashlinn K; Yawson, Abena Konadu; Boamah, Ellen Abrafi; Agyei, Oscar; Mujtaba, Mohammed; Kaali, Seyram; Kinney, Patrick; Owusu-Agyei, Seth

    2015-09-22

    Household air pollution exposure is a major health risk, but validated interventions remain elusive. The Ghana Randomized Air Pollution and Health Study (GRAPHS) is a cluster-randomized trial that evaluates the efficacy of clean fuels (liquefied petroleum gas, or LPG) and efficient biomass cookstoves in the Brong-Ahafo region of central Ghana. We recruit pregnant women into LPG, efficient cookstove, and control arms and track birth weight and physician-assessed severe pneumonia incidence in the first year of life. A woman is eligible to participate if she is in the first or second trimester of pregnancy and carrying a live singleton fetus, if she is the primary cook, and if she does not smoke. We hypothesize that babies born to intervention mothers will weigh more and will have fewer cases of physician-assessed severe pneumonia in the first year of life. Additionally, an extensive personal air pollution exposure monitoring effort opens the way for exposure-response analyses, which we will present alongside intention-to-treat analyses. Major funding was provided by the National Institute of Environmental Health Sciences, The Thrasher Research Fund, and the Global Alliance for Clean Cookstoves. Household air pollution exposure is a major health risk that requires well-tested interventions. GRAPHS will provide important new evidence on the efficacy of both efficient biomass cookstoves and LPG, and will thus help inform health and energy policies in developing countries. The trial was registered with clinicaltrials.gov on 13 April 2011 with the identifier NCT01335490 .

  15. Improved heat recovery and high-temperature clean-up for coal-gas fired combustion turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barthelemy, N.M.; Lynn, S.

    1991-07-01

    This study investigates the performance of an Improved Heat Recovery Method (IHRM) applied to a coal-gas fired power-generating system using a high-temperature clean-up. This heat recovery process has been described by Higdon and Lynn (1990). The IHRM is an integrated heat-recovery network that significantly increases the thermal efficiency of a gas turbine in the generation of electric power. Its main feature is to recover both low- and high-temperature heat reclaimed from various gas streams by means of evaporating heated water into combustion air in an air saturation unit. This unit is a packed column where compressed air flows countercurrently tomore » the heated water prior to being sent to the combustor, where it is mixed with coal-gas and burned. The high water content of the air stream thus obtained reduces the amount of excess air required to control the firing temperature of the combustor, which in turn lowers the total work of compression and results in a high thermal efficiency. Three designs of the IHRM were developed to accommodate three different gasifying process. The performances of those designs were evaluated and compared using computer simulations. The efficiencies obtained with the IHRM are substantially higher those yielded by other heat-recovery technologies using the same gasifying processes. The study also revealed that the IHRM compares advantageously to most advanced power-generation technologies currently available or tested commercially. 13 refs., 34 figs., 10 tabs.« less

  16. Influence of sonication conditions on the efficiency of ultrasonic cleaning with flowing micrometer-sized air bubbles.

    PubMed

    Tuziuti, Toru

    2016-03-01

    This paper describes the sizes of cleaned areas under different sonication conditions with the addition of flowing micrometer-sized air bubbles. The differences in the cleaned area of a glass plate pasted with silicon grease as a dirty material under different sonication conditions were investigated after tiny bubbles were blown on the dirty plate placed in an underwater sound field. The ultrasound was applied perpendicular to the bubble flow direction. The shape of the cleaned areas was nearly elliptical, so the lengths of the minor and major axes were measured. The length of the minor axis under sweep conditions (amplitude modulation), for which the average power was lower than that for continuous wave (CW) irradiation, was comparable to that for CW irradiation and was slightly larger than under bubble flow only. Not only the relatively high power for CW irradiation, but also the larger angular change of the bubble flow direction under sweep conditions contributed to the enlargement of the cleaned area in the direction of the minor axis. The combination of bubble flow and sonication under sweep or CW conditions produced a larger cleaned area compared with bubble flow only, although the increase was not higher than 20%. A rapid change from an air to water interface caused by the bubble flow and water jets caused by the collapse of bubbles due to violent pulsation is the main cleaning mechanism under a combination of ultrasound and bubble flow. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. 14 CFR 1260.34 - Clean air and water.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean air and water. 1260.34 Section 1260... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C. 1319...

  18. 14 CFR 1260.34 - Clean air and water.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 5 2013-01-01 2013-01-01 false Clean air and water. 1260.34 Section 1260... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C. 1319...

  19. 75 FR 11560 - Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-11

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water Act and Clean Air... for the Defendant's violations of the Clean Water Act, 33 U.S.C. 1251 et seq., and the Clean Air Act... including the installation of water effluent controls, the rerouting of air emissions through control...

  20. 75 FR 73026 - Approval and Promulgation of Air Quality Implementation Plans; Indiana; Clean Air Interstate Rule

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-29

    ... Promulgation of Air Quality Implementation Plans; Indiana; Clean Air Interstate Rule AGENCY: Environmental... State Implementation Plan (SIP) under the Clean Air Act (CAA). The State has submitted amendments to the Indiana Administrative Code (IAC), which supplement Indiana's Clean Air Interstate Rule (CAIR), for which...

  1. Cleaning a semipermeable membrane in a papermaking machine

    DOEpatents

    Beck, David A.

    2004-01-06

    A method of cleaning a semipermeable membrane, the semipermeable membrane being configured for carrying a fiber web, includes the steps of providing a cleaning fluid and applying the cleaning fluid on the semipermeable membrane. Further, an air press configured for carrying the semipermeable membrane therethrough is provided, and the air press has pressurized air therein. The semipermeable membrane is conveyed through the air press and is subjected to the pressurized air within the air press. The pressurized air thereby flushes the cleaning fluid through the semipermeable membrane.

  2. Replacing Gasoline : Alternative Fuels for Light-Duty Vehicles

    DOT National Transportation Integrated Search

    1990-09-01

    Among the several major issues that Congress addressed in the process of reauthorizing the Clean Air Act was the future role of alternative highway transportation fuels in reducing urban smog. As vehicular emissions control efficiencies rose past 90 ...

  3. 75 FR 42132 - Notice of Lodging of Consent Decree Pursuant to the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... particulate filters. The hydraulic launch assist refuse collection vehicle is designed to be more efficient by... economy. The diesel particulate filters are aimed to reduce particulate matter emissions as well as carbon...

  4. 75 FR 42131 - Notice of Lodging of Consent Decree Pursuant to the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... particulate filters. The hydraulic launch assist refuse collection vehicle is designed to be more efficient by... economy. The diesel particulate filters are aimed to reduce particulate matter emissions as well as carbon...

  5. Contracting out : benchmarking study : phase 1 : part 2 : external data collection

    DOT National Transportation Integrated Search

    2002-04-17

    The planning provisions of the Intermodal Surface Transportation Efficiency Act of 1991 (ISTEA) and the transportation provisions of the Clean Air Act Amendments of 1990 (CAAA) define the framework for the effective integration of transportation and ...

  6. Energy from Waste--clean, efficient, renewable: transitions in combustion efficiency and NOx control.

    PubMed

    Waldner, M H; Halter, R; Sigg, A; Brosch, B; Gehrmann, H J; Keunecke, M

    2013-02-01

    Traditionally EfW (Energy from Waste) plants apply a reciprocating grate to combust waste fuel. An integrated steam generator recovers the heat of combustion and converts it to steam for use in a steam turbine/generator set. This is followed by an array of flue gas cleaning technologies to meet regulatory limitations. Modern combustion applies a two-step method using primary air to fuel the combustion process on the grate. This generates a complex mixture of pyrolysis gases, combustion gases and unused combustion air. The post-combustion step in the first pass of the boiler above the grate is intended to "clean up" this mixture by oxidizing unburned gases with secondary air. This paper describes modifications to the combustion process to minimize exhaust gas volumes and the generation of noxious gases and thus improving the overall thermal efficiency of the EfW plant. The resulting process can be coupled with an innovative SNCR (Selective Non-Catalytic Reduction) technology to form a clean and efficient solid waste combustion system. Measurements immediately above the grate show that gas compositions along the grate vary from 10% CO, 5% H(2) and 0% O(2) to essentially unused "pure" air, in good agreement with results from a mathematical model. Introducing these diverse gas compositions to the post combustion process will overwhelm its ability to process all these gas fractions in an optimal manner. Inserting an intermediate step aimed at homogenizing the mixture above the grate has shown to significantly improve the quality of combustion, allowing for optimized process parameters. These measures also resulted in reduced formation of NO(x) (nitrogenous oxides) due to a lower oxygen level at which the combustion process was run (2.6 vol% O(2,)(wet) instead of 6.0 vol% O(2,)(wet)). This reduction establishes optimal conditions for the DyNOR™ (Dynamic NO(x) Reduction) NO(x) reduction process. This innovative SNCR technology is adapted to situations typically encountered in solid fuel combustion. DyNOR™ measures temperature in small furnace segments and delivers the reducing reagent to the exact location where it is most effective. The DyNOR™ distributor reacts precisely and dynamically to rapid changes in combustion conditions, resulting in very low NO(x) emissions from the stack. Copyright © 2012 Elsevier Ltd. All rights reserved.

  7. 14 CFR § 1260.34 - Clean air and water.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 5 2014-01-01 2014-01-01 false Clean air and water. § 1260.34 Section Â... AGREEMENTS General Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable... the Clean Air Act (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C. 1319...

  8. Optimization of PECVD Chamber Cleans Through Fundamental Studies of Electronegative Fluorinated Gas Discharges.

    NASA Astrophysics Data System (ADS)

    Langan, John

    1996-10-01

    The predominance of multi-level metalization schemes in advanced integrated circuit manufacturing has greatly increased the importance of plasma enhanced chemical vapor deposition (PECVD) and in turn in-situ plasma chamber cleaning. In order to maintain the highest throughput for these processes the clean step must be as short as possible. In addition, there is an increasing desire to minimize the fluorinated gas usage during the clean, while maximizing its efficiency, not only to achieve lower costs, but also because many of the gases used in this process are global warming compounds. We have studied the fundamental properties of discharges of NF_3, CF_4, and C_2F6 under conditions relevant to chamber cleaning in the GEC rf reference cell. Using electrical impedance analysis and optical emission spectroscopy we have determined that the electronegative nature of these discharges defines the optimal processing conditions by controlling the power coupling efficiency and mechanisms of power dissipation in the discharge. Examples will be presented where strategies identified by these studies have been used to optimize actual manufacturing chamber clean processes. (This work was performed in collaboration with Mark Sobolewski, National Institute of Standards and Technology, and Brian Felker, Air Products and Chemicals, Inc.)

  9. Potential Evaluation of Solar Heat Assisted Desiccant Hybrid Air Conditioning System

    NASA Astrophysics Data System (ADS)

    Tran, Thien Nha; Hamamoto, Yoshinori; Akisawa, Atsushi; Kashiwagi, Takao

    The solar thermal driven desiccant dehumidification-absorption cooling hybrid system has superior advantage in hot-humid climate regions. The reasonable air processing of desiccant hybrid air conditioning system and the utility of clean and free energy make the system environment friendly and energy efficient. The study investigates the performance of the desiccant dehumidification air conditioning systems with solar thermal assistant. The investigation is performed for three cases which are combinations of solar thermal and absorption cooling systems with different heat supply temperature levels. Two solar thermal systems are used in the study: the flat plate collector (FPC) and the vacuum tube with compound parabolic concentrator (CPC). The single-effect and high energy efficient double-, triple-effect LiBr-water absorption cooling cycles are considered for cooling systems. COP of desiccant hybrid air conditioning systems are determined. The evaluation of these systems is subsequently performed. The single effect absorption cooling cycle combined with the flat plate collector solar system is found to be the most energy efficient air conditioning system.

  10. 48 CFR 23.801 - Authorities.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Ozone-Depleting Substances 23.801 Authorities. (a) Title VI of the Clean Air Act... Environmental, Energy, and Transportation Management. (d) Executive Order 13514 of October 5, 2009, Federal...

  11. 48 CFR 23.801 - Authorities.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... PROGRAMS ENVIRONMENT, ENERGY AND WATER EFFICIENCY, RENEWABLE ENERGY TECHNOLOGIES, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Ozone-Depleting Substances 23.801 Authorities. (a) Title VI of the Clean Air Act... Environmental, Energy, and Transportation Management. (d) Executive Order 13514 of October 5, 2009, Federal...

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION TEST PROTOCOL, GENERAL VENTILATION FILTERS

    EPA Science Inventory

    The Environmental Technology Verification Test Protocol, General Ventilation Filters provides guidance for verification tests.

    Reference is made in the protocol to the ASHRAE 52.2P "Method of Testing General Ventilation Air-cleaning Devices for Removal Efficiency by P...

  13. 77 FR 44672 - Notice of Lodging of Consent Decree Under the Clean Water and Clean Air Acts

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-30

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Water and Clean Air Acts... a civil penalty of $1,750,000 to resolve its violations of the Clean Air Act and the Clean Water Act... of coke oven gas. Under the Clean Water Act, Plaintiffs allege that Shenango violated the effluent...

  14. AIR CLEANING FOR ACCEPTABLE INDOOR AIR QUALITY

    EPA Science Inventory

    The paper discusses air cleaning for acceptable indoor air quality. ir cleaning has performed an important role in heating, ventilation, and air-conditioning systems for many years. raditionally, general ventilation air-filtration equipment has been used to protect cooling coils ...

  15. 78 FR 17229 - Notice of Lodging of Proposed Consent Decree Amendment Under the Clean Air Act; the Clean Water...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-20

    ... Act; the Clean Water Act; the Resource Conservation and Recovery Act; the Missouri Air Conservation Law; the Missouri Clean Water Law and the Missouri Hazardous Waste Management Law On March 14, 2013..., the Missouri Air Conservation Law, the Clean Water Act, the Missouri Clean Water Law, the Resource...

  16. Highway Safety Information System guidebook for the Utah state data files. Volume 2 : single variable tabulations

    DOT National Transportation Integrated Search

    1996-07-01

    The increasingly sophisticated demands placed on transportation planning models by the 1990 Clean Air Act Amendments (CAAA), the 1991 Intermodal Surface Transportation Efficiency Act (ISTEA), and to a lesser extent some earlier legislation, have led ...

  17. Simulating Oil Spill Burns to Improve Clean Up and Protect Air Quality

    EPA Pesticide Factsheets

    EPA experts are joining the U.S. Department of Interior’s Bureau of Safety and Environmental Enforcement (BSEE) to investigate ways to improve oil burn procedures that can lead to more efficient burning and, thus, less emissions and residue.

  18. Evaluation of ionic air purifiers for reducing aerosol exposure in confined indoor spaces.

    PubMed

    Grinshpun, S A; Mainelis, G; Trunov, M; Adhikari, A; Reponen, T; Willeke, K

    2005-08-01

    Numerous techniques have been developed over the years for reducing aerosol exposure in indoor air environments. Among indoor air purifiers of different types, ionic emitters have gained increasing attention and are presently used for removing dust particles, aeroallergens and airborne microorganisms from indoor air. In this study, five ionic air purifiers (two wearable and three stationary) that produce unipolar air ions were evaluated with respect to their ability to reduce aerosol exposure in confined indoor spaces. The concentration decay of respirable particles of different properties was monitored in real time inside the breathing zone of a human manikin, which was placed in a relatively small (2.6 m3) walk-in chamber during the operation of an ionic air purifier in calm air and under mixing air condition. The particle removal efficiency as a function of particle size was determined using the data collected with a size-selective optical particle counter. The removal efficiency of the more powerful of the two wearable ionic purifiers reached about 50% after 15 min and almost 100% after 1.5 h of continuous operation in the chamber under calm air conditions. In the absence of external ventilation, air mixing, especially vigorous one (900 CFM), enhanced the air cleaning effect. Similar results were obtained when the manikin was placed inside a partial enclosure that simulated an aircraft seating configuration. All three stationary ionic air purifiers tested in this study were found capable of reducing the aerosol concentration in a confined indoor space. The most powerful stationary unit demonstrated an extremely high particle removal efficiency that increased sharply to almost 90% within 5-6 min, reaching about 100% within 10-12 min for all particle sizes (0.3-3 microm) tested in the chamber. For the units of the same emission rate, the data suggest that the ion polarity per se (negative vs. positive) does not affect the performance but the ion emission rate does. The effects of particle size (within the tested range) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria) as well as the effects of the manikin's body temperature and its breathing on the ionic purifier performance were either small or insignificant. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when used inside confined spaces with a relatively high surface-to-volume ratio. Ionic air purifiers have become increasingly popular for removing dust particles, aeroallergens and airborne microorganisms from indoor air in various settings. While the indoor air cleaning effect, resulting from unipolar and bipolar ion emission, has been tested by several investigators, there are still controversial claims (favorable and unfavorable) about the performance of commercially available ionic air purifiers. Among the five tested ionic air purifiers (two wearable and three stationary) producing unipolar air ions, the units with a higher ion emission rate provided higher particle removal efficiency. The ion polarity (negative vs. positive), the particle size (0.3-3 microm) and properties (NaCl, PSL, Pseudomonas fluorescens bacteria), as well as the body temperature and breathing did not considerable affected the ionization-driven particle removal. The data suggest that the unipolar ionic air purifiers are particularly efficient in reducing aerosol exposure in the breathing zone when they are used inside confined spaces with a relatively high surface-to-volume ratio (such as automobile cabins, aircraft seating areas, bathrooms, cellular offices, small residential rooms, and animal confinements). Based on our experiments, we proposed that purifiers with a very high ion emission rate be operated in an intermittent mode if used indoors for extended time periods. As the particles migrate to and deposit on indoor surfaces during the operation of ionic air purifiers, some excessive surface contamination may occur, which introduces the need of periodic cleaning these surfaces.

  19. Evaluation of two cleaning methods for the removal of asbestos fibers from carpet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kominsky, J.R.; Freyberg, R.W.; Chesson, J.

    The research study examined the effectiveness of dry vacuuming and wet cleaning for the removal of asbestos fibers from carpet, and evaluated the potential for fiber reentrainment during carpet cleaning activities. Routine carpet cleaning operations using high-efficiency particulate air (HEPA) filtered dry vacuum cleaners and HEPA-filtered hot-water extraction cleaners were simulated on carpet artificially contaminated with asbestos fibers. Overall, wet cleaning the carpet with a hot-water extraction cleaner reduced the level of asbestos contamination by approximately 70 percent. There was no significant evidence of either an increase or a decrease in the asbestos concentration after dry vacuuming. The level ofmore » asbestos contamination had no significant effect on the difference between the carpet asbestos concentrations before and after cleaning. Airborne asbestos concentrations were between two and four times greater during the carpet cleaning activities. The level of asbestos contamination in the carpet cleaning activities. The level of asbestos contamination in the carpet and the type of cleaning method used had no statistically significant effect on the difference between the airborne asbestos concentrations before and during cleaning.« less

  20. The Plain English Guide to the Clean Air Act

    EPA Pesticide Factsheets

    The Plain English Guide to the Clean Air Act provides a brief introduction to the 1990 Clean Air Act. This summary covers some of the important provisions of the 1990 Clean Air Act and may help you understand what is in the law and how it may affect you.

  1. 75 FR 42131 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act Notice is hereby... Defendants' violations of the Clean Air Act, 42 U.S.C. 7411 et seq., and the New Jersey Air Pollution Control... compliance with regulations promulgated pursuant to the Clean Air Act. The Department of Justice will receive...

  2. CLEAN-ROADS project: air quality considerations after the application of a novel MDSS on winter road maintenance activities

    NASA Astrophysics Data System (ADS)

    Pretto, Ilaria; Malloci, Elisa; Tonidandel, Gabriele; Benedetti, Guido; Di Napoli, Claudia; Piazza, Andrea; Apolloni, Roberto; Cavaliere, Roberto

    2016-04-01

    With this poster we present the environmental benefit on air quality derived by the application of the CLEAN-ROADS pilot project. The CLEAN-ROADS project addresses the problem of the environmental pollution caused by de-icing salts during winter road maintenance activities in the Province of Trento (Italy). A demonstrative Maintenance Decision Support System (MDSS) has been developed in order to improve the intervention procedures of the road management service. Specifically it aims to optimize the efficiency of how available resources (e.g., salt consumption) are currently used while guaranteeing the current level of road safety. The CLEAN-ROADS project has been tested and validated on a test area located in a valley bottom (Adige Valley), where the highest optimization margins are to be expected. The project supports current road maintenance practices, which has proved to be reliable and accurate, with a new scalable and energy-efficient road monitoring system. This system is based on a network of road weather stations (road weather information system, RWIS) installed on the test route. It is capable to collect real-time data about the road conditions and to perform short-term and now-cast road weather forecasts, which actively integrate weather data and bulletins covering the target area [1]. This poster presents the results obtained from a three-year monitoring activity with the aim to (1) determine the impact of de-icing salts on air quality and (2) quantify the improvements obtained by the application of the CLEAN-ROADS project on air quality. The Ambient Air Quality and Cleaner Air for Europe Directive (2008/50/EC) states that contributions to exceedances of particulate matter PM10 limit values that are attributable to road winter salting may be subtracted when assessing compliance with air quality limit values, once provided that reasonable measures have been taken to lower concentrations [2]. As the de-icing salts used in road maintenance are mainly based on sodium chloride, which releases Na+ and Cl-, the estimation of the contribution of road salting to PM10 concentration can be carried out considering only measured concentrations of Na+ and Cl-. However, the presence of these elements might not be due exclusively to salting activities. For this reason data collected during first winter campaign were analysed using the Positive Matrix Factorization (PMF) Model developed by United States Environmental Protection Agency (EPA) to identify the presence of Na+ and Cl- in emission profiles of other PM10 sources (e.g., biomass burning, traffic) [3]. Through this study new guidelines have been defined for the optimization of current road management operations, and their applicability to other area in the Province of Trento has been assessed for future purposes. [1] Pretto I. et al., SIRWEC 2014 conference proceedings, ID:0019 (2014) [2] Ambient Air Quality and Cleaner Air for Europe (CAFE) Directive (2008/50/EC) [3] http://www.epa.gov/air-research/positive-matrix-factorization-model-environmental-data-analyses

  3. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Clean Air-Water Pollution Control Acts. 1274... AGREEMENTS WITH COMMERCIAL FIRMS Other Provisions and Special Conditions § 1274.926 Clean Air-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative agreement or supplement...

  4. Cleaning and modification of intraorally contaminated titanium discs with calcium phosphate powder abrasive treatment.

    PubMed

    Tastepe, Ceylin S; Liu, Yuelian; Visscher, Corine M; Wismeijer, Daniel

    2013-11-01

    The aim of this study was to evaluate the cleaning efficiency on intraorally contaminated titanium discs by using calcium phosphate and air powder abrasive (APA) treatment. The modification of titanium surface (SLA) was evaluated and compared with the conventional air powder abrasive methods and phosphoric acid. This treatment modality might give new perspectives for peri-implant surface treatment. A total of 36 SLA surface titanium discs were kept in the human mouth for 48 h by 14 volunteers. The intraorally contaminated discs were stained with erythrosine dye to make the biofilm visible. Discs were randomly assigned to one of the six groups: APA without powder-only water and air (Control). APA with Hydroxylapatite (HA). APA with Hydroxylapatite and Calcium Phosphate (HA + TCP). APA with Titanium Dioxide (TiO2). APA with EMS Soft Subgingival powder (EMS). Phosphoric Acid. Light microscope photos were taken during the treatment. Following the cleaning, the residual biofilm, surface changes, and surface chemical content were evaluated using Scanning Electron Microscopy (SEM) and Energy Dispersive X-Ray Spectroscopy (EDS). A systematic random sampling protocol and a point counting method were applied for the quantitative evaluation of the remaining biofilm. Multiple comparisons within and between groups are performed by Kruskall Wallis test and if significant Mann-Whitney U-test as post hoc testing is applied. The significance level was P < 0.05. All methods with the exception of phosphoric acid could decrease the initial amount of biofilm significantly. Among all air powder abrasive treatments, the HA + TCP group showed the best results with 99% biofilm removal, followed by HA and EMS powders. The cleaning method caused minimal changes to the surface structure. With the exception of the control group, all air powder applications caused sharp edges around the grooves in the implant surface to be rounded. TiO2 powder caused less change than HA and HA + TCP. Phosphoric acid did not cause a visible surface change on the SEM photos. Powder particles remnants were observed on and impacted in the titanium surface. In the HA and HA + TCP group, a Ca content was observed varying between 2% and 5%. In the control group, saliva and biofilm-related elements were observed. Using the air powder abrasive method with calcium phosphate powders on contaminated titanium discs, an efficient implant cleaning and surface modification can be achieved. This method should be further improved as it has possible potential to be used as an implant surface treatment method for implants involved with peri-implantitis. © 2012 John Wiley & Sons A/S.

  5. Biosafety level 3 laboratory for autopsies of patients with severe acute respiratory syndrome: principles, practices, and prospects.

    PubMed

    Li, Ling; Gu, Jiang; Shi, Xicheng; Gong, Encong; Li, Xingwang; Shao, Hongquan; Shi, Xueying; Jiang, Huijun; Gao, Xiaoqiang; Cheng, Daiyun; Guo, Lizhu; Wang, Hao; Shi, Xiaohong; Wang, Peizhi; Zhang, Qianying; Shen, Bing

    2005-09-15

    During the outbreak of the emergent severe acute respiratory syndrome (SARS) infection, >30% of the approximately 8000 infected persons were health care workers. The highly infectious nature of SARS coronavirus (SARS-CoV) compelled our pathologists to consider biosafety issues in the autopsy room and for tissue processing procedures. A specially designed biosafety level 3 (BSL-3) autopsy laboratory was constructed and divided into a clean area, a semicontaminated area, a contaminated area, and 2 buffer zones. High-efficiency particulate air filters were placed in the air supply and exhaust systems. Laminar air flow was from the clean areas to the less clean areas. The negative pressures of the contaminated, semicontaminated, and clean areas were approximately -50 pa, -25 pa, and -5 pa, respectively. Personal protective equipment, including gas mask, impermeable protective clothing, and 3 layers of gloves worn during autopsies; the equipment was decontaminated before it was allowed to exit the facility. Strict BSL-3 practices were followed. When a given concentration of particulate sarin simulant was introduced into the contaminated area, it could not be detected in either the semicontaminated area or clean area, and particles >0.3 microm in size were not detected in the exhaust air. A total of 16 complete postmortem examinations for probable and suspected SARS were performed during a 2-month period. Of these, 7 reported confirmed cases of SARS. None of the 23 pathologists and technicians who participated in these autopsies was infected with SARS-CoV. Our experience suggests that BSL-3 laboratory operating principles should be among the special requirements for performing autopsies of contaminated bodies and that they can safeguard the clinicians and the environment involved in these procedures.

  6. 76 FR 61738 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-10-05

    ... United States and the Allegheny County Health Department for violations of the Clean Air Act, 42 U.S.C... and the Allegheny County Health Department allege that Eastman violated the Clean Air Act by failing... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act Notice is hereby...

  7. Air pollution : status of implementation and issues of the Clean Air Act Amendments of 1990 : report to the chairman, Subcommittee on Clean Air, Wetlands, Private Property, and Nuclear Safety, Committee on Environment and Public Works, U.S. Senate

    DOT National Transportation Integrated Search

    2000-04-01

    With reauthorization of the Clean Air Act impending, the General Accounting Office (GAO) was asked to provide information on the implementation of the first six titles of the 1990 Clean Air Act amendments. Specifically they were asked to (1) provide ...

  8. Air Cleaning Devices for HVAC Supply Systems in Schools. Technical Bulletin.

    ERIC Educational Resources Information Center

    Wheeler, Arthur E.

    Guidelines for maintaining indoor air quality in schools with HVAC air cleaning systems are provided in this document. Information is offered on the importance of air cleaning, sources of air contaminants and indoor pollutants, types of air cleaners and particulate filters used in central HVAC systems, vapor and gas removal, and performance…

  9. 40 CFR 63.53 - Application content for case-by-case MACT determinations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... identified emission point or group of affected emission points, an identification of control technology in... on the design, operation, size, estimated control efficiency and any other information deemed... CATEGORIES Requirements for Control Technology Determinations for Major Sources in Accordance With Clean Air...

  10. 40 CFR 63.53 - Application content for case-by-case MACT determinations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... identified emission point or group of affected emission points, an identification of control technology in... on the design, operation, size, estimated control efficiency and any other information deemed... CATEGORIES Requirements for Control Technology Determinations for Major Sources in Accordance With Clean Air...

  11. 40 CFR 63.53 - Application content for case-by-case MACT determinations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... identified emission point or group of affected emission points, an identification of control technology in... on the design, operation, size, estimated control efficiency and any other information deemed... CATEGORIES Requirements for Control Technology Determinations for Major Sources in Accordance With Clean Air...

  12. 40 CFR 63.53 - Application content for case-by-case MACT determinations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... identified emission point or group of affected emission points, an identification of control technology in... on the design, operation, size, estimated control efficiency and any other information deemed... CATEGORIES Requirements for Control Technology Determinations for Major Sources in Accordance With Clean Air...

  13. The Future of Aircraft Paint Removal Methods

    DTIC Science & Technology

    1989-09-01

    barium, cadmium, chromium, lead, mercury , selenium, and silver. We must develop small efficient blast furnaces to burn the media thus reducing the...permit the safe collection, consolidation, and detoxication of stripping waste. This may be as simple as a series of filters to clean the air from

  14. Clean Air Act Text

    EPA Pesticide Factsheets

    The Clean Air Act is the law that defines EPA's responsibilities for protecting and improving the nation's air quality and the stratospheric ozone layer. The last major change in the law, the Clean Air Act Amendments of 1990, enacted in 1990 by Congress.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ottney, T.C.

    Filtration systems that are incorrectly selected, installed and maintained can cause excessive particulates in occupied spaces. This article describes how to identify and correct problems. Particulate matter can be removed from ventilation air at several sites within a building. These sites include: on heat exchanger surfaces; inside ductwork, ceiling tiles and diffusers; and in the air filter. The cost associated with removing these unwanted contaminants is unavoidable. However, this removal cost varies depending on where the particulates have been deposited. Not all particulates that are generated by work-related activities are transported to the filter bank by return air currents beforemore » being deposited on other surfaces. Accordingly, walls still have to be repainted at varying intervals and carpeting vacuumed. Ceiling tiles will discolor at a rate that is influenced by their texture, the air outlet velocity, the amount of dirt in the ventilation air and how much contaminant is being generated in the room. It is estimated that 15% of ventilation air escapes the air filtration process. This leakage results in higher utility, janitorial and redecorating costs as well as contributing to employee absenteeism. When building management does not prevent it, air-conditioning coils and ductwork become an unintended part of the building's air filtration system. In time, this is much more expensive both in energy and cleaning costs than the steps available to keep them clean. Good particulate control can lower the total cost of building operation. However, a building operator may not have to upgrade to a higher efficiency filter to achieve higher system efficiency. Simply eliminating the source of leaks and better management of the existing filters may be all that is necessary.« less

  16. AIR POLLUTION AND RESPIRATORY DISEASE

    EPA Science Inventory

    Concern about polluted air in our urban and industrial areas began gathering momentum shortly after World War II. At that time it seemed obvious that clean air, like clean water, clean food, and a clean body, was a worth while goal in itself, requiring no further justification. B...

  17. 75 FR 10503 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-08

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act Notice is hereby... alleged violations of the Clean Air Act at the DEGs of Narrows, LLC facility in Narrows, Virginia. The complaint alleged that DEGs of Narrows, LLC violated the Clean Air Act, Sections 110, 112 and 502 of the CAA...

  18. Self-Cleaning Particulate Prefilter Media

    NASA Technical Reports Server (NTRS)

    Weber, Olivia; Lalwani, San-jiv; Sharma, Anjal

    2012-01-01

    A long-term space mission requires efficient air revitalization performance to sustain the crew. Prefilter and particulate air filter media are susceptible to rapid fouling that adversely affects their performance and can lead to catastrophic failure of the air revitalization system, which may result in mission failure. For a long-term voyage, it is impractical to carry replacement particulate prefilter and filter modules due to the usual limitations in size, volume, and weight. The only solution to this problem is to reagentlessly regenerate prefilter and filter media in place. A method was developed to modify the particulate prefilter media to allow them to regenerate reagentlessly, and in place, by the application of modest thermocycled transverse or reversed airflows. The innovation may allow NASA to close the breathing air loop more efficiently, thereby sustaining the vision for manned space exploration missions of the future. A novel, self-cleaning coatings technology was developed for air filter media surfaces that allows reagentless in-place regeneration of the surface. The technology grafts thermoresponsive and nonspecific adhesion minimizing polymer nanolayer brush coatings from the prefilter media. These polymer nanolayer brush architectures can be triggered to contract and expand to generate a "pushing-off" force by the simple application of modestly thermocycled (i.e. cycling from ambient cabin temperature to 40 C) air streams. The nonspecific adhesion-minimizing properties of the coatings do not allow the particulate foulants to adhere strongly to the filter media, and thermocycled air streams applied to the media allow easy detachment and in-place regeneration of the media with minimal impact in system downtime or astronaut involvement in overseeing the process.

  19. Experimental investigation of the formaldehyde removal mechanisms in a dynamic botanical filtration system for indoor air purification.

    PubMed

    Wang, Zhiqiang; Pei, Jingjing; Zhang, Jensen S

    2014-09-15

    Botanical filtration has been proved to be effective for indoor gas pollutant removal. To understand the roles of different transport, storage and removal mechanism by a dynamic botanical air filter, a series of experimental investigations were designed and conducted in this paper. Golden Pothos (Epipremnum aureum) plants was selected for test, and its original soil or activated/pebbles root bed was used in different test cases. It was found that flowing air through the root bed with microbes dynamically was essential to obtain meaningful formaldehyde removal efficiency. For static potted plant as normally place in rooms, the clean air delivery rate (CADR), which is often used to quantify the air cleaning ability of portable air cleaners, was only ∼ 5.1m(3)/h per m(2) bed, while when dynamically with air flow through the bed, the CADR increased to ∼ 233 m(3)/h per m(2) bed. The calculated CADR due to microbial activity is ∼ 108 m(3)/h per m(2) bed. Moisture in the root bed also played an important role, both for maintaining a favorable living condition for microbes and for absorbing water-soluble compounds such as formaldehyde. The role of the plant was to introduce and maintain a favorable microbe community which effectively degraded the volatile organic compounds adsorbed or absorbed by the root bed. The presence of the plant increased the removal efficiency by a factor of two based on the results from the bench-scale root bed experiments. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. 78 FR 44947 - Request for Nominations for 2014 Clean Air Excellence Awards Program

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-25

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9838-8] Request for Nominations for 2014 Clean Air Excellence... Air Excellence Awards. SUMMARY: This notice announces the competition for the 2014 Clean Air... that the EPA's Office of Air and Radiation (OAR) announces the opening of competition for the 2014...

  1. Measurement of sub-parts-per-billion levels of carbonyl compounds in marine air by a simple cartridge trapping procedure followed by liquid chromatography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Xianliang, Zhou; Mopper, K.

    1990-10-01

    Carbonyl compounds in clean marine air were trapped onto 2,4-dinitrophenylhydrazine- (DNPH-) coated cartridges, and their hydrazone derivatives were separated by HPLC and detected by UV absorbance. More than 20 carbonyl compounds were isolated from marine air with >92% collection efficiency. The technique employs a highly effective reagent purification procedure, which results in much lower blanks compared to previously reported trapping techniques for carbonyl compounds. Blanks were routinely <0.07 ppb for formaldehyde and acetone and <0.02 ppb for the others. Humidity and reactive gases have no detectable effect on collection efficiencies. Carbonyl-DNPH derivatives eluted from the cartridges are stable in acetonitrilemore » for at least 2 weeks, which facilitates field studies. Several previously undetected unknown carbonyl compounds were found in marine air by this technique. Typical results for open ocean and coastal marine air are shown.« less

  2. Predicting wood pellet stove ownership and acquisition in Albuquerque, NM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lansford, R.; Skaggs, R.; Owensby, F.

    1994-12-31

    Wood pellet stove (WPS) ownership and acquisition in Albuquerque, New Mexico was predicted using a model of qualitative choice. Using data obtained from a telephone survey, households were divided into four groups: current WPS owners, non-owners considering ownership, non-owners not considering ownership, and those who had not heard of WPS technology. Variables used to predict what category a household will be in include homeowners` socioeconomic and home-heating characteristics. Results indicate few WPS stoves are currently in use in Albuquerque. However, current WPS owners and those considering WPS acquisition tend to have higher incomes, more years of education, larger homes, andmore » use their fireplaces more frequently than average. Clean air regulations in Albuquerque will require changes in home woodburning. The WPS is an efficient and clean device; however, lack of knowledge of WPS technology, satisfaction with current heating systems, and limited awareness of the potential impact of clean air regulations indicate WPS usage in Albuquerque will remain limited.« less

  3. QFD analysis of RSRM aqueous cleaners

    NASA Technical Reports Server (NTRS)

    Marrs, Roy D.; Jones, Randy K.

    1995-01-01

    This paper presents a Quality Function Deployment (QFD) analysis of the final down-selected aqueous cleaners to be used on the Redesigned Solid Rocket Motor (RSRM) program. The new cleaner will replace solvent vapor degreasing. The RSRM Ozone Depleting Compound Elimination program is discontinuing the methyl chloroform vapor degreasing process and replacing it with a spray-in-air aqueous cleaning process. Previously, 15 cleaners were down-selected to two candidates by passing screening tests involving toxicity, flammability, cleaning efficiency, contaminant solubility, corrosion potential, cost, and bond strength. The two down-selected cleaners were further evaluated with more intensive testing and evaluated using QFD techniques to assess suitability for cleaning RSRM case and nozzle surfaces in preparation for adhesive bonding.

  4. California Clean Tech

    EPA Pesticide Factsheets

    The California Clean Air Technology Initiative is a partnership to develop clean air technologies for the San Joaquin Valley and South Coast Air Basins through collaborative projects in technology research, development, demonstration, and deployment.

  5. 14 CFR 1260.34 - Clean air and water.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Clean air and water. 1260.34 Section 1260.34... Provisions § 1260.34 Clean air and water. Clean Air and Water October 2000 (Applicable only if the award... (42 U.S.C. 1857c-8(c)(1) or the Federal Water Pollution Control Act (33 U.S.C. 1319(c)), and is listed...

  6. 75 FR 51807 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-23

    ... a Public Teleconference of the Clean Air Scientific Advisory Committee (CASAC) Ambient Air Methods... announcing a public teleconference on September 15, 2010, of the Clean Air Scientific Advisory Committee (CASAC) Ambient Air Monitoring & Methods Subcommittee (AAMMS or Subcommittee) to provide advice on EPA's...

  7. SITE PROGRAM APPLICATIONS ANALYSIS ASSESSMENT OF SUPERFUND APPLICATIONS FOR THE AMERICAN COMBUSTION INC. PYRETRON OXYGEN ENHANCED BURNER

    EPA Science Inventory

    Incineration is widely used to clean up Superfund sites. Modifications which improve the efficiency with which waste can be incinerated are therefore of interest to EPA. Oxygen/air burners are of interest because their installation on conventional incinerators can allow for signi...

  8. Working in a Vacuum

    ERIC Educational Resources Information Center

    Rathey, Allen

    2005-01-01

    In this article, the author discusses several myths about vacuum cleaners and offers tips on evaluating and purchasing this essential maintenance tool. These myths are: (1) Amps mean performance; (2) Everyone needs high-efficiency particulate air (HEPA): (3) Picking up a "bowling ball" shows cleaning power; (4) All vacuum bags are the same; (5)…

  9. In-Situ Air Sparaing: Engineering and Design

    DTIC Science & Technology

    2008-01-31

    Construction Materials. Although PVC casing is commonly used, flexible or rigid polyethylene pipe may be more efficient for certain excavation methods, such as...depth, etc.) Piping insulation/ heat tape installed Piping flushed/cleaned/pressure tested Subsurface as-built equipment...4-4 Figure 4-2 Pilot-Scale Piping and Instrumentation Diagram

  10. 78 FR 39533 - Power Sector Carbon Pollution Standards

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-01

    ..., issuing Clean Air Act standards limiting the greenhouse gas emissions of new cars and light trucks through... Department of Transportation, which, at the same time, established fuel efficiency standards for cars and... Sources: Electric Utility Generating Units,'' 77 Fed. Reg. 22392. In light of the information conveyed in...

  11. Test Report - CleanCook Model A1 Stove with Alcohol Fuel - Air Pollutant Emissions and Fuel Efficiency

    EPA Science Inventory

    Test results were obtained in accordance with ISO (International Organization for Standardization) IWA (International Workshop Agreement) 11:2012 that was unanimously affirmed by more than 90 stakeholders at the ISO International Workshop on Cookstoves on February 28-29, 2012 in ...

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS, AIRFLOW PRODUCTS AFP30

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the AFP30 air filter for dust and bioaerosol filtration manufactured by Airflow Products. The pressure drop across the filter was 62 Pa clean and 247 Pa dust loaded. The filtration effici...

  13. A commitment to coal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shea, Q.

    2006-07-15

    Quin Shea explores the need for power generated with coal and the advanced technologies that will generate that power more efficiently and cleanly in the future. The article considers the air and waste challenges of using coal, including progress toward reducing emissions of SO{sub 2}, NOx, and mercury; efforts to address CO{sub 2}, including voluntary programs like the Climate Challenge, Power Partners, and the Asia-Pacific Partnership on Clean Development and Climate; and the regulation and beneficial use of coal-combustion byproducts (e.g., fly ash, bottom ash, flue gas desulfurization materials, boiler slag). 17 refs.

  14. 40th Anniversary of the Clean Air Act

    EPA Pesticide Factsheets

    On September 14, 2010, EPA celebrated the 40th anniversary of the Clean Air Act with a conference to examine the successes and challenges of the Clean Air Act over the past four decades and explore the future of air quality, energy, and climate change.

  15. Clean Air Act Permitting in Nevada

    EPA Pesticide Factsheets

    Information on Clean Air Act permitting in Nevada in Nevada and EPA's oversight. Clean Air Act permitting in Nevada is the shared responsibility of one state and two local agencies, along with EPA Region 9.

  16. Chapter 4: Assessing the Air Pollution, Greenhouse Gas, Air Quality, and Health Benefits of Clean Energy Initiatives

    EPA Pesticide Factsheets

    Chapter 4 of Assessing the Multiple Benefits of Clean Energy helps state states understand the methods, models, opportunities, and issues associated with assessing the GHG, air pollution, air quality, and human health benefits of clean energy options.

  17. Proceedings of the 21st DOE/NRC Nuclear Air Cleaning Conference; Sessions 1--8

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    First, M.W.

    1991-02-01

    Separate abstracts have been prepared for the papers presented at the meeting on nuclear facility air cleaning technology in the following specific areas of interest: air cleaning technologies for the management and disposal of radioactive wastes; Canadian waste management program; radiological health effects models for nuclear power plant accident consequence analysis; filter testing; US standard codes on nuclear air and gas treatment; European community nuclear codes and standards; chemical processing off-gas cleaning; incineration and vitrification; adsorbents; nuclear codes and standards; mathematical modeling techniques; filter technology; safety; containment system venting; and nuclear air cleaning programs around the world. (MB)

  18. Benefits and Costs of the Clean Air Act

    EPA Pesticide Factsheets

    Congress added to the 1990 Clean Air Act Amendments a requirement under section 812 that EPA conduct periodic, scientifically reviewed studies to assess the benefits and the costs of the entire Clean Air Act.

  19. 78 FR 2260 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-10

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9769-3] Proposed Consent Decree, Clean Air Act Citizen Suit... public comment period. SUMMARY: On December 7, 2012, in accordance with section 113(g) of the Clean Air... promulgate emission standards for hazardous air pollutant emissions from brick and structural clay products...

  20. Pollution reduction technologies being applied to small coal-fired boiler systems in Poland

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Markussen, J.M.; Gyorke, D.F.

    1997-12-31

    To help in alleviating air pollution problems in Poland, various US environmental technologies are being installed in the city of Krakow to reduce emissions from short-stack coal- and coke-fired boilers. Introduction of low-cost, effective US pollution abatement and energy efficiency technologies is being completed through the US-Polish Krakow Clean Fossil Fuels and Energy Efficiency Program. Seven US firms are currently participating in the program; five projects are well under way and two are in the design phase. The technologies being applied in Krakow include modern district heating equipment and controls, coal preparation techniques, micronized coal combustion, automatic combustion controls, andmore » high-efficiency particulate control equipment. These technologies will be discussed along with pollutant reduction results obtained to date. Applications of these technologies are providing some efficient and economical answers to Krakow`s severe air pollution problems. Certainly, these technologies could be equally effective in many industrial cities throughout the world with similar air pollution concerns.« less

  1. Virtual impactor

    DOEpatents

    Yeh, Hsu-Chi; Chen, Bean T.; Cheng, Yung-Sung; Newton, George J.

    1988-08-30

    A virtual impactor having improved efficiency and low wall losses in which a core of clean air is inserted into the aerosol flow while aerosol flow is maintained adjacent inner wall surfaces of the focusing portion of the impactor. The flow rate of the core and the length of the throat of the impactor's collection probe, as well as the dimensional relationships of other components of the impactor adjacent the separation region of the impactor, are selected to optimize separation efficiency.

  2. A review of AirQ Models and their applications for forecasting the air pollution health outcomes.

    PubMed

    Oliveri Conti, Gea; Heibati, Behzad; Kloog, Itai; Fiore, Maria; Ferrante, Margherita

    2017-03-01

    Even though clean air is considered as a basic requirement for the maintenance of human health, air pollution continues to pose a significant health threat in developed and developing countries alike. Monitoring and modeling of classic and emerging pollutants is vital to our knowledge of health outcomes in exposed subjects and to our ability to predict them. The ability to anticipate and manage changes in atmospheric pollutant concentrations relies on an accurate representation of the chemical state of the atmosphere. The task of providing the best possible analysis of air pollution thus requires efficient computational tools enabling efficient integration of observational data into models. A number of air quality models have been developed and play an important role in air quality management. Even though a large number of air quality models have been discussed or applied, their heterogeneity makes it difficult to select one approach above the others. This paper provides a brief review on air quality models with respect to several aspects such as prediction of health effects.

  3. 40 CFR 144.31 - Application for a permit; authorization by permit.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Significant Deterioration (PSD) program under the Clean Air Act. (2) Name, mailing address, and location of... (PSD) program under the Clean Air Act. (v) Nonattainment program under the Clean Air Act. (vi) National...

  4. 40 CFR 144.31 - Application for a permit; authorization by permit.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Significant Deterioration (PSD) program under the Clean Air Act. (2) Name, mailing address, and location of... (PSD) program under the Clean Air Act. (v) Nonattainment program under the Clean Air Act. (vi) National...

  5. 40 CFR 144.31 - Application for a permit; authorization by permit.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Significant Deterioration (PSD) program under the Clean Air Act. (2) Name, mailing address, and location of... (PSD) program under the Clean Air Act. (v) Nonattainment program under the Clean Air Act. (vi) National...

  6. 40 CFR 144.31 - Application for a permit; authorization by permit.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Significant Deterioration (PSD) program under the Clean Air Act. (2) Name, mailing address, and location of... (PSD) program under the Clean Air Act. (v) Nonattainment program under the Clean Air Act. (vi) National...

  7. 75 FR 34673 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ... Halogenated Solvent Cleaning Machines: State of Rhode Island Department of Environmental Management AGENCY... machines in Rhode Island, except for continuous web cleaning machines. This approval would grant RI DEM the... Halogenated Solvent NESHAP for organic solvent cleaning machines and would make the Rhode Island Department of...

  8. Should You Have the Air Ducts in Your Home Cleaned?

    EPA Pesticide Factsheets

    2017-02-14

    Duct cleaning generally refers to the cleaning of various heating and cooling system components of forced air systems, including the supply and return air ducts and registers, grilles and diffusers, heat exchangers heating and cooling coils.

  9. Air pollution and chronic airway diseases: what should people know and do?

    PubMed

    Jiang, Xu-Qin; Mei, Xiao-Dong; Feng, Di

    2016-01-01

    The health effects of air pollution remain a public health concern worldwide. Exposure to air pollution has many substantial adverse effects on human health. Globally, seven million deaths were attributable to the joint effects of household and ambient air pollution. Subjects with chronic respiratory diseases such as chronic obstructive pulmonary disease (COPD) and asthma are especially vulnerable to the detrimental effects of air pollutants. Air pollution can induce the acute exacerbation of COPD and onset of asthma, increase the respiratory morbidity and mortality. The health effects of air pollution depend on the components and sources of pollutants, which varied with countries, seasons, and times. Combustion of solid fuels is a major source of air pollutants in developing countries. To reduce the detrimental effects of air pollution, people especially those with COPD or asthma should be aware of the air quality and take extra measures such as reducing the time outdoor and wearing masks when necessary. For reducing the air pollutants indoor, people should use clean fuels and improve the stoves so as to burn fuel more efficiently and vent emissions to the outside. Air cleaners that can improve the air quality efficiently are recommended.

  10. Air pollution and chronic airway diseases: what should people know and do?

    PubMed Central

    Jiang, Xu-Qin; Feng, Di

    2016-01-01

    The health effects of air pollution remain a public health concern worldwide. Exposure to air pollution has many substantial adverse effects on human health. Globally, seven million deaths were attributable to the joint effects of household and ambient air pollution. Subjects with chronic respiratory diseases such as chronic obstructive pulmonary disease (COPD) and asthma are especially vulnerable to the detrimental effects of air pollutants. Air pollution can induce the acute exacerbation of COPD and onset of asthma, increase the respiratory morbidity and mortality. The health effects of air pollution depend on the components and sources of pollutants, which varied with countries, seasons, and times. Combustion of solid fuels is a major source of air pollutants in developing countries. To reduce the detrimental effects of air pollution, people especially those with COPD or asthma should be aware of the air quality and take extra measures such as reducing the time outdoor and wearing masks when necessary. For reducing the air pollutants indoor, people should use clean fuels and improve the stoves so as to burn fuel more efficiently and vent emissions to the outside. Air cleaners that can improve the air quality efficiently are recommended. PMID:26904251

  11. 77 FR 14830 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-13

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act Notice is hereby... Clean Air Act, 42 U.S.C. 7413(b). Defendant processes aluminum scrap and dross to produce various secondary aluminum products, a process that results in emissions of regulated air pollutants, including...

  12. ENVIRONMENTAL TECHNOLOGY VERIFICATION, TEST REPORT OF CONTROL OF BIOAEROSOLS IN HVAC SYSTEMS, COLUMBUS INDUSTRIES SL-3 RING PANEL

    EPA Science Inventory

    The Environmental Technology Verification report discusses the technology and performance of the High Efficiency Mini Pleat air filter for dust and bioaerosol filtration manufactured by Columbus Industries. The pressure drop across the filter was 142 Pa clean and 283 Pa dust load...

  13. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Within...

  14. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  15. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  16. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  17. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  18. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Within...

  19. 40 CFR 60.3066 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3066 Section 60... Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3066 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste...

  20. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Within...

  1. Hydrophobic and porous cellulose nanofibrous screen for efficient particulate matter (PM2.5) blocking

    NASA Astrophysics Data System (ADS)

    Chen, Liping; Guo, Yi; Peng, Xinsheng

    2017-10-01

    Particulate matter (PM2.5) pollution in air seriously affects public health. However, both bulk thickness and the accumulation of PM particles typically lead to a quick decline in the air permeability and large pressure drops of the conventional air clean membranes. In this work, we choose cellulose nanofibers (CNFs, a low cost, biodegradable and sustainable material) to form a hydrophobic and porous CNF thin layer on a stainless steel screen (300 mesh with pore size of 48 µm) through a simple filtration-assisted gelation process and subsequent polydimethylsiloxane modification. The prepared hydrophobic CNFs/stainless steel screen demonstrates highly efficient PM2.5 blocking based on size-sieving effect, fast air permeability and long-term durability under natural ventilation conditions in the relative humidity range from 45% to 93%. This technique holds great potential for indoor PM2.5 blocking under natural ventilation conditions.

  2. Diesel Combustion and Emission Using High Boost and High Injection Pressure in a Single Cylinder Engine

    NASA Astrophysics Data System (ADS)

    Aoyagi, Yuzo; Kunishima, Eiji; Asaumi, Yasuo; Aihara, Yoshiaki; Odaka, Matsuo; Goto, Yuichi

    Heavy-duty diesel engines have adopted numerous technologies for clean emissions and low fuel consumption. Some are direct fuel injection combined with high injection pressure and adequate in-cylinder air motion, turbo-intercooler systems, and strong steel pistons. Using these technologies, diesel engines have achieved an extremely low CO2 emission as a prime mover. However, heavy-duty diesel engines with even lower NOx and PM emission levels are anticipated. This study achieved high-boost and lean diesel combustion using a single cylinder engine that provides good engine performance and clean exhaust emission. The experiment was done under conditions of intake air quantity up to five times that of a naturally aspirated (NA) engine and 200MPa injection pressure. The adopted pressure booster is an external supercharger that can control intake air temperature. In this engine, the maximum cylinder pressure was increased and new technologies were adopted, including a monotherm piston for endurance of Pmax =30MPa. Moreover, every engine part is newly designed. As the boost pressure increases, the rate of heat release resembles the injection rate and becomes sharper. The combustion and brake thermal efficiency are improved. This high boost and lean diesel combustion creates little smoke; ISCO and ISTHC without the ISNOx increase. It also yields good thermal efficiency.

  3. Control of asthma triggers in indoor air with air cleaners: a modeling analysis.

    PubMed

    Myatt, Theodore A; Minegishi, Taeko; Allen, Joseph G; Macintosh, David L

    2008-08-06

    Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30-55% lower cat allergen levels, 90-99% lower risk of respiratory infection through the inhalation route of exposure, 90-98% lower environmental tobacco smoke (ETS) levels, and 50-75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice.

  4. Control of asthma triggers in indoor air with air cleaners: a modeling analysis

    PubMed Central

    Myatt, Theodore A; Minegishi, Taeko; Allen, Joseph G; MacIntosh, David L

    2008-01-01

    Background Reducing exposure to environmental agents indoors shown to increase asthma symptoms or lead to asthma exacerbations is an important component of a strategy to manage asthma for individuals. Numerous investigations have demonstrated that portable air cleaning devices can reduce concentrations of asthma triggers in indoor air; however, their benefits for breathing problems have not always been reproducible. The potential exposure benefits of whole house high efficiency in-duct air cleaners for sensitive subpopulations have yet to be evaluated. Methods We used an indoor air quality modeling system (CONTAM) developed by NIST to examine peak and time-integrated concentrations of common asthma triggers present in indoor air over a year as a function of natural ventilation, portable air cleaners, and forced air ventilation equipped with conventional and high efficiency filtration systems. Emission rates for asthma triggers were based on experimental studies published in the scientific literature. Results Forced air systems with high efficiency filtration were found to provide the best control of asthma triggers: 30–55% lower cat allergen levels, 90–99% lower risk of respiratory infection through the inhalation route of exposure, 90–98% lower environmental tobacco smoke (ETS) levels, and 50–75% lower fungal spore levels than the other ventilation/filtration systems considered. These results indicate that the use of high efficiency in-duct air cleaners provide an effective means of controlling allergen levels not only in a single room, like a portable air cleaner, but the whole house. Conclusion These findings are useful for evaluating potential benefits of high efficiency in-duct filtration systems for controlling exposure to asthma triggers indoors and for the design of trials of environmental interventions intended to evaluate their utility in practice. PMID:18684328

  5. Cleaning products and air fresheners: exposure to primary and secondary air pollutants

    NASA Astrophysics Data System (ADS)

    Nazaroff, William W.; Weschler, Charles J.

    Building occupants, including cleaning personnel, are exposed to a wide variety of airborne chemicals when cleaning agents and air fresheners are used in buildings. Certain of these chemicals are listed by the state of California as toxic air contaminants (TACs) and a subset of these are regulated by the US federal government as hazardous air pollutants (HAPs). California's Proposition 65 list of species recognized as carcinogens or reproductive toxicants also includes constituents of certain cleaning products and air fresheners. In addition, many cleaning agents and air fresheners contain chemicals that can react with other air contaminants to yield potentially harmful secondary products. For example, terpenes can react rapidly with ozone in indoor air generating many secondary pollutants, including TACs such as formaldehyde. Furthermore, ozone-terpene reactions produce the hydroxyl radical, which reacts rapidly with organics, leading to the formation of other potentially toxic air pollutants. Indoor reactive chemistry involving the nitrate radical and cleaning-product constituents is also of concern, since it produces organic nitrates as well as some of the same oxidation products generated by ozone and hydroxyl radicals. Few studies have directly addressed the indoor concentrations of TACs that might result from primary emissions or secondary pollutant formation following the use of cleaning agents and air fresheners. In this paper, we combine direct empirical evidence with the basic principles of indoor pollutant behavior and with information from relevant studies, to analyze and critically assess air pollutant exposures resulting from the use of cleaning products and air fresheners. Attention is focused on compounds that are listed as HAPs, TACs or Proposition 65 carcinogens/reproductive toxicants and compounds that can readily react to generate secondary pollutants. The toxicity of many of these secondary pollutants has yet to be evaluated. The inhalation intake of airborne organic compounds from cleaning product use is estimated to be of the order of 10 mg d -1 person -1 in California. More than two dozen research articles present evidence of adverse health effects from inhalation exposure associated with cleaning or cleaning products. Exposure to primary and secondary pollutants depends on the complex interplay of many sets of factors and processes, including cleaning product composition, usage, building occupancy, emission dynamics, transport and mixing, building ventilation, sorptive interactions with building surfaces, and reactive chemistry. Current understanding is sufficient to describe the influence of these variables qualitatively in most cases and quantitatively in a few.

  6. A 14-year longitudinal study of the impact of clean indoor air legislation on state smoking prevalence, USA, 1997-2010.

    PubMed

    Becker, Craig M; Lee, Joseph G L; Hudson, Suzanne; Hoover, Jeanne; Civils, Donald

    2017-06-01

    While clean indoor air legislation at the state level is an evidence-based recommendation, only limited evidence exists regarding the impact of clean indoor air policies on state smoking prevalence. Using state smoking prevalence data from 1997 to 2010, a repeated measures observational analysis assessed the association between clean indoor air policies (i.e., workplace, restaurant, and bar) and state smoking prevalence while controlling for state cigarette taxes and year. The impacts from the number of previous years with any clean indoor air policy, the number of policies in effect during the current year, and the number of policies in effect the previous year were analyzed. Findings indicate a smoking prevalence predicted decrease of 0.13 percentage points (p=0.03) for each additional year one or more clean indoor air policies were in effect, a predicted decrease of 0.12 percentage points (p=0.09) for each policy in effect in the current year, and a predicted decrease of 0.22 percentage points (p=0.01) for each policy in effect in the previous year on the subsequent year. Clean indoor air policies show measurable associations with reductions in smoking prevalence within a year of implementation above and beyond taxes and time trends. Further efforts are needed to diffuse clean indoor air policies across states and provinces that have not yet adopted such policies. Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.

  7. Household air pollution, health, and climate change: cleaning the air

    NASA Astrophysics Data System (ADS)

    Goldemberg, Jose; Martinez-Gomez, Javier; Sagar, Ambuj; Smith, Kirk R.

    2018-03-01

    Air pollution from the use of solid household fuels is now recognized to be a major health risk in developing countries. Accordingly, there has been some shift in development thinking and investment from previous efforts, which has focused only on improving the efficiency of household fuel use, to those that focus on reducing exposure to the air pollution that leads to health impact. Unfortunately, however, this is occurring just as the climate agenda has come to dominate much of the discourse and action on international sustainable development. Thus, instead of optimizing approaches that centrally focus on the large health impact, the household energy agenda has been hampered by the constraints imposed by a narrow definition of sustainability—one primarily driven by the desire to mitigate greenhouse emissions by relying on renewable biomass fueling so-called improved cookstoves. In reality, however, solid biomass is extremely difficult to burn sufficiently cleanly in household stoves to reach health goals. In comparison to the international development community, however, some large countries, notably Brazil historically and more recently, India have substantially expanded the use of liquefied petroleum gas (LPG) in their household energy mix, using their own resources, having a major impact on their national energy picture. The net climate impact of such approaches compared to current biomass stoves is minimal or non-existent, and the social and health benefits are, in contrast, potentially great. LPG can be seen as a transition fuel for clean household energy, with induction stoves powered by renewables as the holy grail (an approach already being adopted by Ecuador as also discussed here). The enormous human and social benefits of clean energy, rather than climate concerns, should dominate the household energy access agenda today.

  8. [ESTIMATION OF THE EFFICIENCY OF THE TREATMENT OF SPLIT-SYSTEMS IN RESIDENTIAL AREAS IN ORDER TO REDUCE THE LEVEL OF THE PREVALENCE OF DISEASES OF THE RESPIRATORY SYSTEM].

    PubMed

    Rakhmanin Yu A; Shibanov, S E; Kozulya, S V

    2016-01-01

    The purpose of work: comparison of prevalence among residents, which use or fail to use to clean split systems. Collected information about morbidity rate in 235 cases people during 3 years. The usage of split-systems without their regular cleaning leads to the gain in the level of the prevalence of respiratory diseases by 172.7% if compared with persons, who have no air conditioning systems at home. Also, the average number of disability days increases by 218.1%) and average time of the duration of the disease increases by 71.9%. The annual treatment of split-systems and regular cleaning of filters allowed to reduce the number of diseases. In comparison with the group of people, who fail to clean air conditioning systems, the drop of morbidity rate by 56.6%, average number of disability days by 63.3% and average time of diseases by 30.9% was observed. Regular treatment of air conditioning systems cannot completely repay the morbidity rates to the level of the control group. In comparison with the people, who use no air conditioning systems, the owners of split-systems with regular treatment have lung diseases by 18.4% more often. The average number of disability days and the average time of diseases increased by 16.9% and 18.8%. These changes can be explained by the impact of unfavorable (cooling) microclimate. The impact of split-systems on the health of the population requires a comprehensive study and the subsequent development of normative documents regulating their safe use.

  9. The Benefits and Costs of the Clean Air Act, 1970 to 1990 (1997)

    EPA Pesticide Factsheets

    Final report to Congress prepared in response to Section 812 of the 1990 Clean Air Act Amendments addressing the question of how the overall health, welfare, ecological, and economic benefits of Clean Air Act Programs compare to the costs of these programs

  10. 77 FR 39737 - Notice of Lodging of Proposed Consent Decree With Dairyland Power Cooperative Under the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-05

    ... Cooperative Under the Clean Air Act Pursuant to 28 CFR 50.7, notice is hereby given that on June 28, 2012, a... Wisconsin. In this civil enforcement action under the federal Clean Air Act (``Act''), the United States... intended to protect air quality. The complaint alleges that Dairyland violated the Prevention of...

  11. 75 FR 4070 - Science Advisory Board Staff Office; Notification of a Public Meeting of the Air Quality Modeling...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-26

    ... Prospective Analysis of the benefits and costs of the Clean Air Act. DATES: The meeting date is Friday... support the Second Prospective Section 812 Benefit-Cost Analysis of the Clean Air Act. The Council was... studies to assess benefits and costs of the EPA's regulatory actions under the Clean Air Act. The Council...

  12. Control of cavitation using dissolved carbon dioxide for damage-free megasonic cleaning of wafers

    NASA Astrophysics Data System (ADS)

    Kumari, Sangita

    This dissertation describes the finding that dissolved carbon dioxide is a potent inhibitor of sonoluminescence and describes the implications of the finding in the development of improved megasonic cleaning formulations. Megasonic cleaning, or the removal of contaminants particles from wafer surfaces using sound-irradiated cleaning fluids, has been traditionally used in the semiconductor industry for cleaning of wafers. A critical challenge in the field is to achieve removal of small particles (22 nm to 200 nm) without causing damage to fine wafer features. The work described here addresses this challenge by identifying sonoluminescence and solution pH as two key factors affecting damage and cleaning efficiency, respectively and establishing novel means to control them using CO2(aq) release compounds in the presence of acids and bases. Sonoluminescence (SL) behavior of the major dissolved gases such as Ar, Air, N2, O2 and CO2 was determined using a newly designed Cavitation Threshold Cell (CT Cell). SL, which is the phenomenon of release of light in sound-irradiated liquids, is a sensitive indicator of cavitation, primarily transient cavitation. It was found that all the tested dissolved gases such as Ar, Air, N2 and O2, generated SL signal efficiently. However, dissolved CO2 was found to be completely incapable of generating SL signal. Based on this interesting result, gradual suppression of SL signal was demonstrated using CO2(aq). It was further demonstrated that CO2(aq) is not only incapable but is also a potent inhibitor of SL. The inhibitory role of CO2(aq) was established using a novel method of controlled in-situ release of CO 2 from NH4HCO3. ~130 ppm CO2(aq) was shown to be necessary and sufficient for complete suppression of SL generation in air saturated DI water. The method however required acidification of solution for significant release of CO2, making it unsuitable for the design of cleaning solutions at high pH. Analysis of the underlying ionic equilibria revealed that the loss of released CO2(aq) upon increase in pH can be compensated by moderate increase in added NH4HCO3. Using this method, simultaneous control of SL and solution pH was demonstrated in two systems, NH4HCO3/HCl and NH4OH/CO2, at two nominal pH values; 5.7 and 7.0. Damage studies were performed on wafer samples with line/space patterns donated by IMEC and FSI International bearing Si/metal/a-Si gate stacks of thickness ~36 nm and Si/Poly-Si gate stacks of thickness ~67 nm, respectively. A single wafer spin cleaning tool MegPieRTM was used for the generation of megasonic energy for inducing damage to the structures. It was demonstrated that CO2 dissolution in DI water suppresses damage to the gate stacks in a dose-dependent manner. Together, these studies establish a systematic and strong correlation between CO2(aq) concentration, SL suppression and damage suppression. Significant damage reduction (~50 % to ~90 %) was observed at [CO2(aq)] > ~300 ppm. It was also demonstrated that CO2(aq) suppresses damage under alkaline pH condition too. This demonstration was made possible by the successful design of two new cleaning systems NH4HCO3/NH4OH and CO2/NH 4OH that could generate CO2(aq) under alkaline conditions. Damage suppressing ability of the newly designed cleaning systems were compared to the standard cleaning system NH4OH at pH 8.2 and it was found that NH4HCO3/NH4OH and CO2/NH 4OH systems were 80 % more efficient in suppressing damage compared to the standard NH4OH cleaning system. Finally, megasonic cleaning studies were conducted in the same single wafer spin cleaning tool MegPieRTM, using SiO2 particles (size 185 nm) deposited on 200 mm oxide Si wafers, as the contaminant. It was found that the standard cleaning chemical, NH4OH, pH 8.2, was effective in achieving > 95 % particle removal for 2 min irradiation of megasonic energy at power densities > 0.7 W/cm2. Based on these results, a new system, NH4HCO3/NH4OH, was designed with an aim to release ~300 ppm CO2 at pH 8.2. It was demonstrated that newly designed system NH4HCO3/NH 4OH, allowed significant suppression of damage in comparison to NH 4OH while maintaining > 90 % cleaning efficiency that was comparable to NH4OH solution, at the same acoustic power densities. Taken together, these studies establish a potent and flexible means for the inhibition of SL generation over a wide pH range and acoustic power densities and demonstrate its use in suppression of wafer damage without compromising megasonic cleaning efficiency. (Abstract shortened by UMI.)

  13. Protection of the vehicle cab environment against bacteria, fungi and endotoxins in composting facilities.

    PubMed

    Schlosser, O; Huyard, A; Rybacki, D; Do Quang, Z

    2012-06-01

    Microbial quality of air inside vehicle cabs is a major occupational health risk management issue in composting facilities. Large differences and discrepancies in protection factors between vehicles and between biological agents have been reported. This study aimed at estimating the mean protection efficiency of the vehicle cab environment against bioaerosols with higher precision. In-cab measurement results were also analysed to ascertain whether or not these protection systems reduce workers' exposure to tolerable levels. Five front-end loaders, one mobile mixer and two agricultural tractors pulling windrow turners were investigated. Four vehicles were fitted with a pressurisation and high efficiency particulate air (HEPA) filtration system. The four others were only equipped with pleated paper filter without pressurisation. Bacteria, fungi and endotoxins were measured in 72 pairs of air samples, simultaneously collected inside the cab and on the outside of the cab with a CIP 10-M sampler. A front-end loader, purchased a few weeks previously, fitted with a pressurisation and high efficiency particulate air (HEPA) filtration system, and with a clean cab, exhibited a mean protection efficiency of between 99.47% CI 95% [98.58-99.97%] and 99.91% [99.78-99.98%] depending on the biological agent. It is likely that the lower protection efficiency demonstrated in other vehicles was caused by penetration through the only moderately efficient filters, by the absence of pressurisation, by leakage in the filter-sealing system, and by re-suspension of particles which accumulated in dirty cabs. Mean protection efficiency in regards to bacteria and endotoxins ranged between 92.64% [81.87-97.89%] and 98.61% [97.41-99.38%], and between 92.68% [88.11-96.08%] and 98.43% [97.44-99.22%], respectively. The mean protection efficiency was the lowest when confronted with fungal spores, from 59.76% [4.19-90.75%] to 94.71% [91.07-97.37%]. The probability that in-cab exposure to fungi exceeded the benchmark value for short-term respiratory effects suggests that front-end loaders and mobile mixers in composting facilities should be fitted with a pressurisation and HEPA filtration system, regardless of whether or not the facility is indoors or outdoors. Regarding the tractors, exposure inside the cabs was not significantly reduced. However, in this study, there was a less than 0.01% risk of exceeding the bench mark value associated with fungi related short-term respiratory effects during an 1-h per day windrow turning operation. Pressurisation and a HEPA filtration system can provide safe working conditions inside loaders and mobile mixer with regard to airborne bacteria, fungi and endotoxins in composting facilities. However, regular thorough cleaning of the vehicle cab, as well as overalls and shoes cleaning, and mitigation of leakage in the filter-sealing system are necessary to achieve high levels of protection efficiency. Copyright © 2012 Elsevier Ltd. All rights reserved.

  14. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  15. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  16. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  17. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  18. 40 CFR 60.3064 - What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerator that burns only wood waste, clean lumber, and yard waste and then restart it? 60.3064... Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3064 What must I do if I close my air curtain incinerator that burns only wood waste, clean lumber, and yard...

  19. Clean Air Markets

    EPA Pesticide Factsheets

    Clean Air Markets implements regulatory programs such as the Acid Rain Program and the Cross-State Air Pollution Rule to reduce air pollution from the power sector that contributes to human health and environmental issues.

  20. 77 FR 66978 - Proposed Consent Decree, Clean Air Act Citizen Suit

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-08

    ... ENVIRONMENTAL PROTECTION AGENCY [FRL-9750-5] Proposed Consent Decree, Clean Air Act Citizen Suit... public comment. SUMMARY: In accordance with section 113(g) of the Clean Air Act, as amended (``CAA... 5 Generating Plant, a power plant located in Milam County, Texas. Under the proposed consent decree...

  1. 76 FR 9610 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... pollution control technology; undertake periodic equipment testing; and to submit required reports. The... DEPARTMENT OF JUSTICE Notice of Proposed Consent Decree Under the Clean Air Act Notice is hereby... the Eastern District of California. The Consent Decree in this Clean Air Act enforcement action...

  2. Political factors affecting the enactment of state-level clean indoor air laws.

    PubMed

    Tung, Gregory Jackson; Vernick, Jon S; Stuart, Elizabeth A; Webster, Daniel W

    2014-06-01

    We examined the effects of key political institutional factors on the advancement of state-level clean indoor air laws. We performed an observational study of state-level clean indoor air law enactment among all 50 US states from 1993 to 2010 by using extended Cox hazard models to assess risk of enacting a relevant law. During the 18-year period from 1993 to 2010, 28 states passed a law covering workplaces, 33 states passed a law covering restaurants, 29 states passed a law covering bars, and 16 states passed a law covering gaming facilities. States with term limits had a 2.15 times greater hazard (95% confidence interval [CI] = 1.27, 3.65; P = .005) of enacting clean indoor air laws. The presence of state-level preemption of local clean indoor air laws was associated with a 3.26 times greater hazard (95% CI = 1.11, 9.53; P = .031) of state-level policy enactment. In the presence of preemption, increased legislative professionalism was strongly associated (hazard ratio = 3.28; 95% CI = 1.10, 9.75; P = .033) with clean indoor air law enactment. Political institutional factors do influence state-level clean indoor air law enactment and may be relevant to other public health policy areas.

  3. Wood dust particle and mass concentrations and filtration efficiency in sanding of wood materials.

    PubMed

    Welling, Irma; Lehtimäki, Matti; Rautio, Sari; Lähde, Tero; Enbom, Seppo; Hynynen, Pasi; Hämeri, Kaarle

    2009-02-01

    The importance of fine particles has become apparent as the knowledge of their effects on health has increased. Fine particle concentrations have been published for outside air, plasma arc cutting, welding, and grinding, but little data exists for the woodworking industry. Sanding was evaluated as the producer of the woodworking industry's finest particles, and was selected as the target study. The number of dust particles in different particle size classes and the mass concentrations were measured in the following environments: workplace air during sanding in plywood production and in the inlet and return air; in the dust emission chamber; and in filter testing. The numbers of fine particles were low, less than 10(4) particles/cm(3) (10(7) particles/L). They were much lower than typical number concentrations near 10(6) particles/cm(3) measured in plasma arc cutting, grinding, and welding. Ultrafine particles in the size class less than 100 nm were found during sanding of MDF (medium density fiberboard) sheets. When the cleaned air is returned to the working areas, the dust content in extraction systems must be monitored continuously. One way to monitor the dust content in the return air is to use an after-filter and measure pressure drop across the filter to indicate leaks in the air-cleaning system. The best after-filtration materials provided a clear increase in pressure drop across the filter in the loading of the filter. The best after-filtration materials proved to be quite effective also for fine particles. The best mass removal efficiencies for fine particles around 0.3 mum were over 80% for some filter materials loaded with sanding wood dust.

  4. 7 CFR 2.48 - Administrator, Rural Business-Cooperative Service.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Drinking Water Act, as amended (42 U.S.C. 300f et seq.); (iv) Clean Air Act, as amended (42 U.S.C. 7401 et... Innovation Center Demonstration program (note to 7 U.S.C. 1621). (30) Administer the Renewable Energy Systems and Energy Efficiency Improvements program (7 U.S.C. 8106). (30) Administer the renewable energy...

  5. 7 CFR 2.48 - Administrator, Rural Business-Cooperative Service.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Drinking Water Act, as amended (42 U.S.C. 300f et seq.); (iv) Clean Air Act, as amended (42 U.S.C. 7401 et... Innovation Center Demonstration program (note to 7 U.S.C. 1621). (30) Administer the Renewable Energy Systems and Energy Efficiency Improvements program (7 U.S.C. 8106). (30) Administer the renewable energy...

  6. 7 CFR 2.48 - Administrator, Rural Business-Cooperative Service.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Drinking Water Act, as amended (42 U.S.C. 300f et seq.); (iv) Clean Air Act, as amended (42 U.S.C. 7401 et... Innovation Center Demonstration program (note to 7 U.S.C. 1621). (30) Administer the Renewable Energy Systems and Energy Efficiency Improvements program (7 U.S.C. 8106). (30) Administer the renewable energy...

  7. 7 CFR 2.48 - Administrator, Rural Business-Cooperative Service.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... Drinking Water Act, as amended (42 U.S.C. 300f et seq.); (iv) Clean Air Act, as amended (42 U.S.C. 7401 et... Innovation Center Demonstration program (note to 7 U.S.C. 1621). (30) Administer the Renewable Energy Systems and Energy Efficiency Improvements program (7 U.S.C. 8106). (30) Administer the renewable energy...

  8. Airing 'clean air' in Clean India Mission.

    PubMed

    Banerjee, T; Kumar, M; Mall, R K; Singh, R S

    2017-03-01

    The submission explores the possibility of a policy revision for considering clean air quality in recently launched nationwide campaign, Clean India Mission (CIM). Despite of several efforts for improving availability of clean household energy and sanitation facilities, situation remain still depressing as almost half of global population lacks access to clean energy and proper sanitation. Globally, at least 2.5 billion people do not have access to basic sanitation facilities. There are also evidences of 7 million premature deaths by air pollution in year 2012. The situation is even more disastrous for India especially in rural areas. Although, India has reasonably progressed in developing sanitary facilities and disseminating clean fuel to its urban households, the situation in rural areas is still miserable and needs to be reviewed. Several policy interventions and campaigns were made to improve the scenario but outcomes were remarkably poor. Indian census revealed a mere 31% sanitation coverage (in 2011) compared to 22% in 2001 while 60% of population (700 million) still use solid biofuels and traditional cook stoves for household cooking. Further, last decade (2001-2011) witnessed the progress decelerating down with rural households without sanitation facilities increased by 8.3 million while minimum progress has been made in conversion of conventional to modern fuels. To revamp the sanitation coverage, an overambitious nationwide campaign CIM was initiated in 2014 and present submission explores the possibility of including 'clean air' considerations within it. The article draws evidence from literatures on scenarios of rural sanitation, energy practises, pollution induced mortality and climatic impacts of air pollution. This subsequently hypothesised with possible modification in available technologies, dissemination modes, financing and implementation for integration of CIM with 'clean air' so that access to both sanitation and clean household energy may be effectively addressed.

  9. The Clean Air Game.

    ERIC Educational Resources Information Center

    Avalone-King, Deborah

    2000-01-01

    Introduces the Clean Air game which teaches about air quality and its vital importance for life. Introduces students to air pollutants, health of people and environment, and possible actions individuals can take to prevent air pollution. Includes directions for the game. (YDS)

  10. Loading and unloading of freeze-dryers: airborne contamination risks for aseptically manufactured sterile drug products.

    PubMed

    Ljungqvist, Bengt; Reinmüller, Berit

    2007-01-01

    In pharmaceutical manufacturing, freeze-drying processes can be adversely affected by temperature differences relative to the surrounding air. Loading and unloading of freeze-dryers are performed either without or with temperature differences between the cleanroom and the chamber of the freeze-dryer. This operation can cause a flow of room air through the opening, creating a contamination risk, especially when manual handling of material is performed in this area. To minimize this risk, a high-efficiency particulate air (HEPA) filter unit should be installed above the opening to provide clean air and protect the opening. Here the theoretical relationships are discussed and design criteria are presented.

  11. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  12. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn...

  13. 40 CFR 60.2971 - What are the emission limitations for air curtain incinerators that burn only wood waste, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2971 Section 60... Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2971 What are the emission limitations for air curtain incinerators that burn...

  14. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  15. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  16. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  17. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  18. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  19. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  20. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste... incinerator that burns only wood waste, clean lumber, and yard waste? Yes, if your air curtain incinerator is...

  1. 1990 Clean Air Act Amendment Summary

    EPA Pesticide Factsheets

    In 1989, President George W. Bush proposed revisions to the Clean Air Act designed to curb acid rain, urban air pollution, and toxic air emissions. The proposal also called for establishing a national permits program.

  2. Virtual impactor

    DOEpatents

    Yeh, H.C.; Chen, B.T.; Cheng, Y.S.; Newton, G.J.

    1988-08-30

    A virtual impactor is described having improved efficiency and low wall losses in which a core of clean air is inserted into the aerosol flow while aerosol flow is maintained adjacent to the inner wall surfaces of the focusing portion of the impactor. The flow rate of the core and the length of the throat of the impactor's collection probe, as well as the dimensional relationships of other components of the impactor adjacent the separation region of the impactor, are selected to optimize separation efficiency. 4 figs.

  3. The impact of flood and post-flood cleaning on airborne microbiological and particle contamination in residential houses.

    PubMed

    He, Congrong; Salonen, Heidi; Ling, Xuan; Crilley, Leigh; Jayasundara, Nadeesha; Cheung, Hing Cho; Hargreaves, Megan; Huygens, Flavia; Knibbs, Luke D; Ayoko, Godwin A; Morawska, Lidia

    2014-08-01

    In January 2011, Brisbane, Australia, experienced a major river flooding event. We aimed to investigate its effects on air quality and assess the role of prompt cleaning activities in reducing the airborne exposure risk. A comprehensive, multi-parameter indoor and outdoor measurement campaign was conducted in 41 residential houses, 2 and 6 months after the flood. The median indoor air concentrations of supermicrometer particle number (PN), PM10, fungi and bacteria 2 months after the flood were comparable to those previously measured in Brisbane. These were 2.88 p cm(-3), 15 μg m(-3), 804 cf um(-3) and 177 cf um(-3) for flood-affected houses (AFH), and 2.74 p cm(-3), 15 μg m(-3), 547 cf um(-3) and 167 cf um(-3) for non-affected houses (NFH), respectively. The I/O (indoor/outdoor) ratios of these pollutants were 1.08, 1.38, 0.74 and 1.76 for AFH and 1.03, 1.32, 0.83 and 2.17 for NFH, respectively. The average of total elements (together with transition metals) in indoor dust was 2296 ± 1328 μg m(-2) for AFH and 1454 ± 678 μg m(-2) for NFH, respectively. In general, the differences between AFH and NFH were not statistically significant, implying the absence of a measureable effect on air quality from the flood. We postulate that this was due to the very swift and effective cleaning of the flooded houses by 60,000 volunteers. Among the various cleaning methods, the use of both detergent and bleach was the most efficient at controlling indoor bacteria. All cleaning methods were equally effective for indoor fungi. This study provides quantitative evidence of the significant impact of immediate post-flood cleaning on mitigating the effects of flooding on indoor bioaerosol contamination and other pollutants. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Phase I Recommendations by the Air Quality Management Work Group to the Clean Air Act Advisory Committee

    EPA Pesticide Factsheets

    Recommendations to the Clean Air Act Advisory Committee by Air Quality Management Work Group addressing the recommendations made by the National Research Council to improve the U.S. air quality management system.

  5. 1990 Clean Air Act Amendment Summary: Title III

    EPA Pesticide Factsheets

    This page provides an overview of the 1990 amendments to Title III of the Clean Air Act, which were enacted to curb acid rain, urban air pollution and toxic air emissions. The edits to this title deal with toxic air pollutants.

  6. Frequency and longitudinal trends of household care product use

    NASA Astrophysics Data System (ADS)

    Moran, Rebecca E.; Bennett, Deborah H.; Tancredi, Daniel J.; Wu, Xiangmei (May); Ritz, Beate; Hertz-Picciotto, Irva

    2012-08-01

    The use of household cleaning products and air fresheners exposes people to a variety of chemicals, including some that have been shown to be irritants, potential carcinogens and endocrine disrupting compounds. In addition, some react with ambient ozone infiltrating to the indoor environment to form potentially toxic secondary pollutants. Although realistic estimates of usage patterns are necessary for modeling potential exposures in risk assessments, few studies have documented cleaning habits and product usage to characterize how they vary between households and over time. In addition, understanding within-household temporal variability of use is important to assess the reliability of exposure questionnaires used in epidemiological surveys and improve the cost-efficiency of data collection. In the SUPERB (Study of Use of Products and Exposure-Related Behavior) study, frequencies of use of eight types of household cleaning products and air fresheners and the performance of different types of cleaning tasks are collected in three annual telephone and six quarterly web-based surveys. All-purpose and glass cleaners were the products most frequently used among all products surveyed. Use frequencies differed by demographic and other household characteristics for some products. Product usage was internally consistent, with over 75% of pairwise cross-sectional correlations between product types statistically significantly different from zero. In addition, each product type was correlated with at least one cleaning habit. Frequency of cleaning product use and performing cleaning tasks did not vary by season. An examination of intra-household variability showed moderately to highly consistent usage patterns over time, with lower temporal consistency observed among products used more frequently, such as all-purpose cleaners. Frequency of household care product usage was consistent enough that in epidemiologic studies, participants can be classified, for example, into three categories on the basis of a single assessment, with only minimal misclassification.

  7. 78 FR 15376 - Notice of Lodging of Proposed Consent Decree Amendment Under the Clean Air Act; the Clean Water...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-11

    ... Act; the Clean Water Act; the Resource Conservation and Recovery Act; the Emergency Planning and...'') for violations of the Clean Air Act, the Resource Conservation and Recovery Act, the Clean Water Act... Herculaneum Lead Smelter Facility 12-month rolling average limit for SO 2 emissions and the 12-month rolling...

  8. 76 FR 23876 - Clarifications to Indian Tribes' Clean Air Act Regulatory Requirements; Direct Final Amendments

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-29

    ... Clarifications to Indian Tribes' Clean Air Act Regulatory Requirements; Direct Final Amendments AGENCY... to amend certain Clean Air Act regulations pertaining to Indian tribes. This action changes the title... Subpart L, which includes provisions specific to implementation plans for tribes located in EPA Region IX...

  9. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... ensure a supply of clean, dry air. (3) Pressure gages. Each retort should be equipped with a pressure... should have adequate filter systems to ensure a supply of clean, dry air. (3) Pressure gages. (i) Each... controllers should have adequate filter systems to ensure a supply of clean, dry air. (3) Pressure gages. Each...

  10. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... have adequate filter systems to ensure a supply of clean, dry air. A steam controller activated by the... ensure a supply of clean, dry air. (5) Steam introduction. Steam shall be distributed in the bottom of... temperature controllers should have adequate filter systems to ensure a supply of clean, dry air. (5) Bleeders...

  11. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... have adequate filter systems to ensure a supply of clean, dry air. A steam controller activated by the... ensure a supply of clean, dry air. (5) Steam introduction. Steam shall be distributed in the bottom of... temperature controllers should have adequate filter systems to ensure a supply of clean, dry air. (5) Bleeders...

  12. 21 CFR 113.40 - Equipment and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... have adequate filter systems to ensure a supply of clean, dry air. A steam controller activated by the... ensure a supply of clean, dry air. (5) Steam introduction. Steam shall be distributed in the bottom of... temperature controllers should have adequate filter systems to ensure a supply of clean, dry air. (5) Bleeders...

  13. Effectiveness of HVAC duct cleaning procedures in improving indoor air quality.

    PubMed

    Ahmad, I; Tansel, B; Mitrani, J D

    2001-12-01

    Indoor air quality has become one of the most serious environmental concerns as an average person spends about 22 hr indoors on a daily basis. The study reported in this article, was conducted to determine the effectiveness of three commercial HVAC (Heating Ventilation Air Conditioning) duct cleaning processes in reducing the level of airborne particulate matter and viable bioaerosols. The three HVAC sanitation processes were: (1) Contact method (use of conventional vacuum cleaning of interior duct surfaces); (2) Air sweep method (use of compressed air to dislodging dirt and debris); (3) Rotary brush method (insertion of a rotary brush into the ductwork to agitate and dislodge the debris). Effectiveness of these sanitation processes was evaluated in terms of airborne particulate and viable bioaerosol concentrations in residential homes. Eight identical homes were selected in the same neighborhood. Two homes were cleaned using each procedure and two were used as controls. It was found that both particle count readings and bioaerosol concentrations were higher when cleaning was being performed than before or after cleaning, which suggests that dirt, debris and other pollutants may become airborne as a result of disturbances caused by the cleaning processes. Particle count readings at 0.3 micron size were found to have increased due to cigarette smoking. Particle counts at 1.0 micron size were reduced due to HVAC duct cleaning. Post-level bioaerosol concentrations, taken two days after cleaning, were found to be lower than the pre-level concentrations suggesting that the cleaning procedures were effective to some extent. Homes cleaned with the Air Sweep procedure showed the highest degree of reduction in bioaerosol concentration among the three procedures investigated.

  14. Air quality management in China: issues, challenges, and options.

    PubMed

    Wang, Shuxiao; Hao, Jiming

    2012-01-01

    This article analyzed the control progress and current status of air quality, identified the major air pollution issues and challenges in future, proposed the long-term air pollution control targets, and suggested the options for better air quality in China. With the continuing growth of economy in the next 10-15 years, China will face a more severe situation of energy consumption, electricity generation and vehicle population leading to increase in multiple pollutant emissions. Controlling regional air pollution especially fine particles and ozone, as well as lowering carbon emissions from fossil fuel consumption will be a big challenge for the country. To protect public health and the eco-system, the ambient air quality in all Chinese cities shall attain the national ambient air quality standards (NAAQS) and ambient air quality guideline values set by the World Health Organization (WHO). To achieve the air quality targets, the emissions of SO2, NOx, PM10, and volatile organic compounds (VOC) should decrease by 60%, 40%, 50%, and 40%, respectively, on the basis of that in 2005. A comprehensive control policy focusing on multiple pollutants and emission sources at both the local and regional levels was proposed to mitigate the regional air pollution issue in China. The options include development of clean energy resources, promotion of clean and efficient coal use, enhancement of vehicle pollution control, implementation of synchronous control of multiple pollutants including SO2, NOx, VOC, and PM emissions, joint prevention and control of regional air pollution, and application of climate friendly air pollution control measures.

  15. Effect of dry-cleaned clothes on tetrachloroethylene levels in indoor air, personal air, and breath for residents of several New Jersey homes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Thomas, K.W.; Pellizzari, E.D.; Perritt, R.L.

    1991-10-01

    Several volatile organic compounds, including tetrachloroethylene, have been found to be nearly ubiquitous in residential indoor environments during previous TEAM studies. Eleven homes in New Jersey were monitored over three or five days to examine the effect of bringing freshly dry-cleaned clothes into the home on indoor air levels and personal exposures to tetrachloroethylene. Indoor air, personal air, and breath concentrations were measured over multiple 12-hrs periods before and after dry-cleaned clothes were introduced into nine of the homes. No dry-cleaned clothes were introduced into the two remaining homes. Outdoor air tetrachloroethylene concentrations were measured at six of the elevenmore » homes. Indoor/outdoor concentration ratios and source strengths were calculated at the six homes with outdoor measurements. Elevated indoor air levels and human exposures to tetrachloroethylene were measured at seven of the nine homes with dry-cleaned clothes. Indoor air concentrations reached 300 micrograms/m3 in one home and elevated indoor levels persisted for at least 48 hrs in all seven homes. Indoor/outdoor tetrachloroethylene concentration ratios exceeded 100 for the four homes with both dry-cleaned clothes and outdoor measurements. Maximum source strengths ranged from 16 to 69 mg/hr in these homes and did not directly correspond to the number of dry-cleaned garments brought into the home. Breath levels of tetrachloroethylene increased two to six-fold for participants living in seven homes with increased indoor air levels. Indoor air, personal air, and breath tetrachloroethylene concentrations were significantly related (0.05 level) to the number of garments introduced divided by the home volume.« less

  16. Significant OH production under surface cleaning and air cleaning conditions: Impact on indoor air quality.

    PubMed

    Carslaw, N; Fletcher, L; Heard, D; Ingham, T; Walker, H

    2017-11-01

    We report measurements of hydroxyl (OH) and hydroperoxy (HO 2 ) radicals made by laser-induced fluorescence spectroscopy in a computer classroom (i) in the absence of indoor activities (ii) during desk cleaning with a limonene-containing cleaner (iii) during operation of a commercially available "air cleaning" device. In the unmanipulated environment, the one-minute averaged OH concentration remained close to or below the limit of detection (6.5×10 5  molecule cm -3 ), whilst that of HO 2 was 1.3×10 7  molecule cm -3 . These concentrations increased to ~4×10 6 and 4×10 8  molecule cm -3 , respectively during desk cleaning. During operation of the air cleaning device, OH and HO 2 concentrations reached ~2×10 7 and ~6×10 8  molecule cm -3 respectively. The potential of these OH concentrations to initiate chemical processing is explored using a detailed chemical model for indoor air (the INDCM). The model can reproduce the measured OH and HO 2 concentrations to within 50% and often within a few % and demonstrates that the resulting secondary chemistry varies with the cleaning activity. Whilst terpene reaction products dominate the product composition following surface cleaning, those from aromatics and other VOCs are much more important during the use of the air cleaning device. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 9 2014-07-01 2014-07-01 false Air-cleaning. 61.152 Section 61.152 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos § 61.152 Air...

  18. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 9 2012-07-01 2012-07-01 false Air-cleaning. 61.152 Section 61.152 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos § 61.152 Air...

  19. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 9 2013-07-01 2013-07-01 false Air-cleaning. 61.152 Section 61.152 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos § 61.152 Air...

  20. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 8 2010-07-01 2010-07-01 false Air-cleaning. 61.152 Section 61.152 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos § 61.152 Air...

  1. 40 CFR 61.152 - Air-cleaning.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 8 2011-07-01 2011-07-01 false Air-cleaning. 61.152 Section 61.152 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos § 61.152 Air...

  2. Environmental Assessment for the Replacement of a Vehicle Wash Rack, Travis Air Force Base, California

    DTIC Science & Technology

    2005-04-01

    meet state and U.S. Air Force (Air Force) environmental requirements for the use of cleaning products and washing systems; comply with Air Force and...and O/WSs • Use environmentally compliant cleaning products and wash systems • Be equipped with a credit card reader or similar device, to document... cleaning products and washing systems, including operating a covered O/WS within design capacity limits • Comply with Air Force and Department of

  3. Ambient air quality trends and driving factor analysis in Beijing, 1983-2007.

    PubMed

    Zhang, Ju; Ouyang, Zhiyun; Miao, Hong; Wang, Xiaoke

    2011-01-01

    The rapid development in Beijing, the capital of China, has resulted in serious air pollution problems. Meanwhile great efforts have been made to improve the air quality, especially since 1998. The variation in air quality under the interaction of pollution and control in this mega city has attracted much attention. We analyzed the changes in ambient air quality in Beijing since the 1980's using the Daniel trend test based on data from long-term monitoring stations. The results showed that different pollutants displayed three trends: a decreasing trend, an increasing trend and a flat trend. SO2, dustfall, B[a]P, NO2 and PM10 fit decreasing trend pattern, while NOx showed an increasing trend, and CO, ozone pollution, total suspended particulate (TSP), as well as Pb fit the flat trend. The cause of the general air pollution in Beijing has changed from being predominantly related to coal burning to mixed traffic exhaust and coal burning related pollution. Seasonally, the pollution level is typically higher during the heating season from November to the following March. The interaction between pollution sources change and implementation of air pollution control measures was the main driving factor that caused the variation in air quality. Changes of industrial structure and improved energy efficiency, the use of clean energy and preferred use of clean coal, reduction in pollution sources, and implementation of advanced environmental standards have all contributed to the reduction in air pollution, particularly since 1998.

  4. Clean Air Technology Center

    EPA Pesticide Factsheets

    The Clean Air Technology Center provides resources for emerging and existing air pollution prevention and control technologies and provides public access to data and information on their use, effectiveness and cost.

  5. 78 FR 1251 - Notice of Lodging of Proposed Consent Decree Under the Clean Air Act, the Clean Water Act and the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-08

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Proposed Consent Decree Under the Clean Air Act, the Clean Water Act and the Resource Conservation and Recovery Act On December 31, 2012, the Department of....C. 7401 et seq.; the Clean Water Act, 33 U.S.C. 1301 et seq.; and the Resource Conservation and...

  6. 1990 Clean Air Act Amendment Summary: Title I

    EPA Pesticide Factsheets

    This page provides an overview of the 1990 amendments to Title I of the Clean Air Act, which were enacted to curb acid rain, urban air pollution and toxic air emissions. The edits to this title deal with the national ambient air quality standards.

  7. Clean air through transportation : challenges in meeting national air quality standards

    DOT National Transportation Integrated Search

    1993-08-01

    This report, required by Section 108(f)(3) of the Clean Air Act, as amended in 1990, addresses the issues of motor vehicles and air quality. The report discusses the challenges faced in attempting to improve air quality through transportation program...

  8. Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System

    NASA Technical Reports Server (NTRS)

    Parrish, Lewis M.

    2009-01-01

    NASA Kennedy Space Center (KSC) recently entered into a nonexclusive license agreement with Applied Cryogenic Solutions (ACS), Inc. (Galveston, TX) to commercialize its Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System technology. This technology, developed by KSC, is a critical component of processes being developed and commercialized by ACS to replace current mechanical and chemical cleaning and descaling methods used by numerous industries. Pilot trials on heat exchanger tubing components have shown that the ACS technology provides for: Superior cleaning in a much shorter period of time. Lower energy and labor requirements for cleaning and de-scaling uper.ninih. Significant reductions in waste volumes by not using water, acidic or basic solutions, organic solvents, or nonvolatile solid abrasives as components in the cleaning process. Improved energy efficiency in post-cleaning heat exchanger operations. The ACS process consists of a spray head containing supersonic converging/diverging nozzles, a source of liquid gas; a novel, proprietary pumping system that permits pumping liquid nitrogen, liquid air, or supercritical carbon dioxide to pressures in the range of 20,000 to 60,000 psi; and various hoses, fittings, valves, and gauges. The size and number of nozzles can be varied so the system can be built in configurations ranging from small hand-held spray heads to large multinozzle cleaners. The system also can be used to verify if a part has been adequately cleaned.

  9. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et seq...

  10. ESTIMATES OF THE ATMOSPHERIC DEPOSITION OF SULFUR AND NITROGEN SPECIES: CLEAN AIR STATUS AND TRENDS NETWORK. 1990 THROUGH 2000

    EPA Science Inventory

    The Clean Air Status and Trends Network (CASTNet) was established by EPA in response to the requirements of the 1990 Clean Air Act Amendments. To satisfy these requirements CASTNet was designed to assess and report on geographic patterns and long-term, temporal trends in ambient ...

  11. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 5 2013-01-01 2013-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et seq...

  12. 14 CFR § 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 5 2014-01-01 2014-01-01 false Clean Air-Water Pollution Control Acts. Â...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et seq...

  13. 14 CFR 1274.926 - Clean Air-Water Pollution Control Acts.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 5 2012-01-01 2012-01-01 false Clean Air-Water Pollution Control Acts...-Water Pollution Control Acts. Clean Air-Water Pollution Control Acts July 2002 If this cooperative... 91-604) and section 308 of the Federal Water Pollution Control Act, as amended (33 U.S.C. 1251 et seq...

  14. Clean Air Technology Center Products

    EPA Pesticide Factsheets

    The Clean Air Technology Center provides resources for emerging and existing air pollution prevention and control technologies and provides public access to data and information on their use, effectiveness and cost.

  15. The successful of finite element to invent particle cleaning system by air jet in hard disk drive

    NASA Astrophysics Data System (ADS)

    Jai-Ngam, Nualpun; Tangchaichit, Kaitfa

    2018-02-01

    Hard Disk Drive manufacturing has faced very challenging with the increasing demand of high capacity drives for Cloud-based storage. Particle adhesion has also become increasingly important in HDD to gain more reliability of storage capacity. The ability to clean on surfaces is more complicated in removing such particles without damaging the surface. This research is aim to improve the particle cleaning in HSA by using finite element to develop the air flow model then invent the prototype of air cleaning system to remove particle from surface. Surface cleaning by air pressure can be applied as alternative for the removal of solid particulate contaminants that is adhering on a solid surface. These technical and economic challenges have driven the process development from traditional way that chemical solvent cleaning. The focus of this study is to develop alternative way from scrub, ultrasonic, mega sonic on surface cleaning principles to serve as a foundation for the development of new processes to meet current state-of-the-art process requirements and minimize the waste from chemical cleaning for environment safety.

  16. Ozone Generators That Are Sold as Air Cleaners

    MedlinePlus

    ... U.S. EPA, 1996a). Top of Page What Other Methods Can Be Used to Control Indoor Air Pollution? ... Air Cleaning: Remove pollutants through proven air cleaning methods. Of the three, the first approach — source control — ...

  17. Clean Air Act Requirements and History

    EPA Pesticide Factsheets

    In 1970 congress designed the Clean Air Act to combat a variety of air pollution problems, and to tackle emerging pollution threats such as public health, national welfare, toxic air pollutants, acid rain, protection of the ozone layer, and regional haze.

  18. 7 CFR 3560.4 - Compliance with other Federal requirements.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 1806, subpart B, or any successor regulation. (c) Clean Air Act and Water Pollution Control Act... the Clean Air Act; section 508 of the Clean Water Act, Executive Order 11738, and 40 CFR part 32. (d...

  19. Should You Have the Air Ducts in Your Home Cleaned?

    MedlinePlus

    ... clean and draining properly? Blower Are the blower blades clean and free of oil and debris? Is ... g., screws, rivets, mastic, etc.)? With the system running, is air leakage through access doors or covers ...

  20. 77 FR 32135 - Notice of Lodging of Consent Decree Under the Clean Air Act and the Emergency Planning and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-31

    ... flare gas recovery systems and improved flaring efficiency, and enhanced controls for leak detection and... the monitoring data to a publicly available Web site on a weekly basis. The Consent Decree also... Department of Justice Web site: http://www.usdoj.gov/enrd/Consent_Decrees.html . A copy of the Decree may...

  1. About the Clean Air Technology Center

    EPA Pesticide Factsheets

    The Clean Air Technology Center provides resources for emerging and existing air pollution prevention and control technologies and provides public access to data and information on their use, effectiveness and cost.

  2. 1990 Clean Air Act Amendment Summary: Title II

    EPA Pesticide Factsheets

    This page provides an overview of the 1990 amendments to Title II of the Clean Air Act, which were enacted to curb acid rain, urban air pollution and toxic air emissions. The edits to this title deal emissions from mobile sources.

  3. 1990 Clean Air Act Amendment Summary: Title IV

    EPA Pesticide Factsheets

    This page provides an overview of the 1990 amendments to Title IV of the Clean Air Act, which were enacted to curb acid rain, urban air pollution and toxic air emissions. The edits to this title deal with acid deposition control.

  4. 1990 Clean Air Act Amendment Summary: Title VII

    EPA Pesticide Factsheets

    This page provides an overview of the 1990 amendments to Title VII of the Clean Air Act, which were enacted to curb acid rain, urban air pollution and toxic air emissions. The edits to this title deal with enforcement provisions.

  5. Air Quality Criteria for Particulate Matter and Sulfur Oxides (Final Report, 1982)

    EPA Science Inventory

    Particulate matter and sulfur oxides are two of six major air pollutants regulated by National Ambient Air Quality Standards (NAAQS) under the U.S. Clean Air Act. As mandated by the Clean Air Act, the U.S. Environmental Protection Agency (EPA) must periodically review the scienti...

  6. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 29 Labor 7 2013-07-01 2013-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  7. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 29 Labor 7 2012-07-01 2012-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  8. 29 CFR 1917.154 - Compressed air.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 29 Labor 7 2014-07-01 2014-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  9. Portable air cleaners should be at the forefront of the public health response to landscape fire smoke.

    PubMed

    Barn, Prabjit K; Elliott, Catherine T; Allen, Ryan W; Kosatsky, Tom; Rideout, Karen; Henderson, Sarah B

    2016-11-25

    Landscape fires can produce large quantities of smoke that degrade air quality in both remote and urban communities. Smoke from these fires is a complex mixture of fine particulate matter and gases, exposure to which is associated with increased respiratory and cardiovascular morbidity and mortality. The public health response to short-lived smoke events typically advises people to remain indoors with windows and doors closed, but does not emphasize the use of portable air cleaners (PAC) to create private or public clean air shelters. High efficiency particulate air filters and electrostatic precipitators can lower indoor concentrations of fine particulate matter and improve respiratory and cardiovascular outcomes. We argue that PACs should be at the forefront of the public health response to landscape fire smoke events.

  10. Working to make the Clean Air Act and prescribed burning compatible

    Treesearch

    Trent Procter

    1995-01-01

    The Federal Clean Air Act of 1963 offers a challenge to the future of prescribed and natural fire programs in the United States. One aspect of maintaining healthy ecosystems for humans and natural resources is clean air. In addition, prescribed and natural fire programs are an important tool in maintaining healthy ecosystems, as well as satisfying the requirements of...

  11. 75 FR 48327 - Science Advisory Board Staff Office; Notification of a Public Meeting of the Advisory Council on...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-10

    ... Analysis of the benefits and costs of the Clean Air Act. DATES: The meeting will be held on Thursday... Second Section 812 Prospective Benefit-Cost Analysis of the Clean Air Act. The Council was established in... Clean Air Act Amendments (CAAA), EPA conducts periodic studies to assess benefits and costs of the EPA's...

  12. 75 FR 75463 - Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-03

    ... ENVIROMENTAL PROTECTION AGENCY [FRL-9234-9] Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper Company, Luke, MD AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of final action. SUMMARY: Pursuant to section 505(b)(2) of the Clean Air Act (CAA), the...

  13. 78 FR 38362 - Notice of Lodging of Proposed Modification to Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-26

    ... States v. American Sugar Refining, Inc. Civil Action No. JKB-12-1408. The Consent Decree in this Clean Air Act enforcement action against American Sugar Refining, Inc. (``ASR'') resolves allegations by the... 113(b) of the Clean Air Act, 42 U.S.C. 7413(b), for alleged environmental violations at ASR's sugar...

  14. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 4 2011-10-01 2011-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water Pollution...

  15. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water Pollution...

  16. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 45 Public Welfare 4 2014-10-01 2014-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water Pollution...

  17. Development of a software and hardware system for monitoring the air cleaning process using a cyclone-separator

    NASA Astrophysics Data System (ADS)

    Nicolaeva, B. K.; Borisov, A. P.; Zlochevskiy, V. L.

    2017-08-01

    The article is devoted to the development of a hardware-software complex for monitoring and controlling the process of air purification by means of a cyclone-separator. The hardware of this complex is the Arduino platform, to which are connected pressure sensors, air velocities, dustmeters, which allow monitoring of the main parameters of the cyclone-separator. Also, a frequency converter was developed to regulate the rotation speed of an asynchronous motor necessary to correct the flow rate, the control signals of which come with Arduino. The program part of the complex is written in the form of a web application in the programming language JavaScript and inserts into CSS and HTML for the user interface. This program allows you to receive data from sensors, build dependencies in real time and control the speed of rotation of an asynchronous electric drive. The conducted experiment shows that the cleaning efficiency is 95-99.9%, while the airflow at the cyclone inlet is 16-18 m/s, and at the exit 50-70 m/s.

  18. Air cleaning technologies: an evidence-based analysis.

    PubMed

    2005-01-01

    This health technology policy assessment will answer the following questions: When should in-room air cleaners be used?How effective are in-room air cleaners?Are in-room air cleaners that use combined HEPA and UVGI air cleaning technology more effective than those that use HEPA filtration alone?What is the Plasmacluster ion air purifier in the pandemic influenza preparation plan?The experience of severe acute respiratory syndrome (SARS) locally, nationally, and internationally underscored the importance of administrative, environmental, and personal protective infection control measures in health care facilities. In the aftermath of the SARS crisis, there was a need for a clearer understanding of Ontario's capacity to manage suspected or confirmed cases of airborne infectious diseases. In so doing, the Walker Commission thought that more attention should be paid to the potential use of new technologies such as in-room air cleaning units. It recommended that the Medical Advisory Secretariat of the Ontario Ministry of Health and Long-Term Care evaluate the appropriate use and effectiveness of such new technologies. Accordingly, the Ontario Health Technology Advisory Committee asked the Medical Advisory Secretariat to review the literature on the effectiveness and utility of in-room air cleaners that use high-efficiency particle air (HEPA) filters and ultraviolet germicidal irradiation (UVGI) air cleaning technology. Additionally, the Ontario Health Technology Advisory Committee prioritized a request from the ministry's Emergency Management Unit to investigate the possible role of the Plasmacluster ion air purifier manufactured by Sharp Electronics Corporation, in the pandemic influenza preparation plan. Airborne transmission of infectious diseases depends in part on the concentration of breathable infectious pathogens (germs) in room air. Infection control is achieved by a combination of administrative, engineering, and personal protection methods. Engineering methods that are usually carried out by the building's heating, ventilation, and air conditioning (HVAC) system function to prevent the spread of airborne infectious pathogens by diluting (dilution ventilation) and removing (exhaust ventilation) contaminated air from a room, controlling the direction of airflow and the air flow patterns in a building. However, general wear and tear over time may compromise the HVAC system's effectiveness to maintain adequate indoor air quality. Likewise, economic issues may curtail the completion of necessary renovations to increase its effectiveness. Therefore, when exposure to airborne infectious pathogens is a risk, the use of an in-room air cleaner to reduce the concentration of airborne pathogens and prevent the spread of airborne infectious diseases has been proposed as an alternative to renovating a HVAC system. Airborne transmission is the spread of infectious pathogens over large distances through the air. Infectious pathogens, which may include fungi, bacteria, and viruses, vary in size and can be dispersed into the air in drops of moisture after coughing or sneezing. Small drops of moisture carrying infectious pathogens are called droplet nuclei. Droplet nuclei are about 1 to 5μm in diameter. This small size in part allows them to remain suspended in the air for several hours and be carried by air currents over considerable distances. Large drops of moisture carrying infectious pathogens are called droplets. Droplets being larger than droplet nuclei, travel shorter distances (about 1 metre) before rapidly falling out of the air to the ground. Because droplet nuclei remain airborne for longer periods than do droplets, they are more amenable to engineering infection control methods than are droplets. Droplet nuclei are responsible for the airborne transmission of infectious diseases such as tuberculosis, chicken pox (varicella), measles (rubeola), and dessiminated herpes zoster, whereas close contact is required for the direct transmission of infectious diseases transmitted by droplets, such as influenza (the flu) and SARS. In-room air cleaners are supplied as portable or fixed devices. Fixed devices can be attached to either a wall or ceiling and are preferred over portable units because they have a greater degree of reliability (if installed properly) for achieving adequate room air mixing and airflow patterns, which are important for optimal effectiveness. Through a method of air recirculation, an in-room air cleaner can be used to increase room ventilation rates and if used to exhaust air out of the room it can create a negative-pressure room for airborne infection isolation (AII) when the building's HVAC system cannot do so. A negative-pressure room is one where clean air flows into the room but contaminated air does not flow out of it. Contaminated room air is pulled into the in-room air cleaner and cleaned by passing through a series of filters, which remove the airborne infectious pathogens. The cleaned air is either recirculated into the room or exhausted outside the building. By filtering contaminated room air and then recirculating the cleaned air into the room, an in-room air cleaner can improve the room's ventilation. By exhausting the filtered air to the outside the unit can create a negative-pressure room. There are many types of in-room air cleaners. They vary widely in the airflow rates through the unit, the type of air cleaning technology used, and the technical design. Crucial to maximizing the efficiency of any in-room air cleaner is its strategic placement and set-up within a room, which should be done in consultation with ventilation engineers, infection control experts, and/or industrial hygienists. A poorly positioned air cleaner may disrupt airflow patterns within the room and through the air cleaner, thereby compromising its air cleaning efficiency. The effectiveness of an in-room air cleaner to remove airborne pathogens from room air depends on several factors, including the airflow rate through the unit's filter and the airflow patterns in the room. Tested under a variety of conditions, in-room air cleaners, including portable or ceiling mounted units with either a HEPA or a non-HEPA filter, portable units with UVGI lights only, or ceiling mounted units with combined HEPA filtration and UVGI lights, have been estimated to be between 30% and 90%, 99% and 12% and 80% effective, respectively. However, and although their effectiveness is variable, the United States Centers for Disease Control and Prevention has acknowledged in-room air cleaners as alternative technology for increasing room ventilation when this cannot be achieved by the building's HVAC system with preference given to fixed recirculating systems over portable ones. Importantly, the use of an in-room air cleaner does not preclude either the need for health care workers and visitors to use personal protective equipment (N95 mask or equivalent) when entering AII rooms or health care facilities from meeting current regulatory requirements for airflow rates (ventilation rates) in buildings and airflow differentials for effective negative-pressure rooms. The Plasmacluster ion technology, developed in 2000, is an air purification technology. Its manufacturer, Sharp Electronics Corporation, says that it can disable airborne microorganisms through the generation of both positive and negative ions. (1) The functional unit is the hydroxyl, which is a molecule comprised of one oxygen molecule and one hydrogen atom. Plasmacluster ion air purifier uses a multilayer filter system composed of a prefilter, a carbon filter, an antibacterial filter, and a HEPA filter, combined with an ion generator to purify the air. The ion generator uses an alternating plasma discharge to split water molecules into positively and negatively charged ions. When these ions are emitted into the air, they are surrounded by water molecules and form cluster ions which are attracted to airborne particles. The cluster ion surrounds the airborne particle, and the positive and negative ions react to form hydroxyls. These hydroxyls steal the airborne particle's hydrogen atom, which creates a hole in the particle's outer protein membrane, thereby rendering it inactive. Because influenza is primarily acquired by large droplets and direct and indirect contact with an infectious person, any in-room air cleaner will have little benefit in controlling and preventing its spread. Therefore, there is no role for the Plasmacluster ion air purifier or any other in-room air cleaner in the control of the spread of influenza. Accordingly, for purposes of this review, the Medical Advisory Secretariat presents no further analysis of the Plasmacluster. The objective of the systematic review was to determine the effectiveness of in-room air cleaners with built in UVGI lights and HEPA filtration compared with those using HEPA filtration only. The Medical Advisory Secretariat searched the databases of MEDLINE, EMBASE, Cochrane Database of Systematic Reviews, INAHATA (International Network of Agencies for Health Technology Assessment), Biosis Previews, Bacteriology Abstracts, Web of Science, Dissertation Abstracts, and NIOSHTIC 2. A meta-analysis was conducted if adequate data was available from 2 or more studies and where statistical and clinical heterogeneity among studies was not an issue. Otherwise, a qualitative review was completed. The GRADE system was used to summarize the quality of the body of evidence comprised of 1 or more studies. There were no existing health technology assessments on air cleaning technology located during the literature review. The literature search yielded 59 citations of which none were retained. (ABSTRACT TRUNCATED)

  19. Accumulation-mode aerosol number concentrations in the Arctic during the ARCTAS aircraft campaign: Long-range transport of polluted and clean air from the Asian continent

    NASA Astrophysics Data System (ADS)

    Matsui, H.; Kondo, Y.; Moteki, N.; Takegawa, N.; Sahu, L. K.; Koike, M.; Zhao, Y.; Fuelberg, H. E.; Sessions, W. R.; Diskin, G.; Anderson, B. E.; Blake, D. R.; Wisthaler, A.; Cubison, M. J.; Jimenez, J. L.

    2011-10-01

    We evaluate the impact of transport from midlatitudes on aerosol number concentrations in the accumulation mode (light-scattering particles (LSP) with diameters >180 nm) in the Arctic during the Arctic Research of the Composition of the Troposphere from Aircraft and Satellites (ARCTAS) campaign. We focus on transport from the Asian continent. We find marked contrasts in the number concentration (NLSP), transport efficiency (TEN_LSP, the fraction transported from sources to the Arctic), size distribution, and the chemical composition of aerosols between air parcels from anthropogenic sources in East Asia (Asian AN) and biomass burning sources in Russia and Kazakhstan (Russian BB). Asian AN air had lower NLSP and TEN_LSP (25 cm-3 and 18% in spring and 6.2 cm-3 and 3.0% in summer) than Russian BB air (280 cm-3 and 97% in spring and 36 cm-3 and 7.6% in summer) due to more efficient wet scavenging during transport from East Asia. Russian BB in this spring is the most important source of accumulation-mode aerosols over the Arctic, and BB emissions are found to be the primary source of aerosols within all the data in spring during ARCTAS. On the other hand, the contribution of Asian AN transport had a negligible effect on the accumulation-mode aerosol number concentration in the Arctic during ARCTAS. Compared with background air, NLSP was 2.3-4.7 times greater for Russian BB air but 2.4-2.6 times less for Asian AN air in both spring and summer. This result shows that the transport of Asian AN air decreases aerosol number concentrations in the Arctic, despite the large emissions of aerosols in East Asia. The very low aerosol number concentrations in Asian AN air were caused by wet removal during vertical transport in association with warm conveyor belts (WCBs). Therefore, this cleansing effect will be prominent for air transported via WCBs from other midlatitude regions and seasons. The inflow of clean midlatitude air can potentially have an important impact on accumulation-mode aerosol number concentrations in the Arctic.

  20. The use of an air filtration system in podiatry clinics.

    PubMed

    McLarnon, Nichola; Burrow, Gordon; Maclaren, William; Aidoo, Kofi; Hepher, Mike

    2003-06-01

    A small-scale study was conducted to ascertain the efficiency and effectiveness of an air filtration system for use in podiatry/chiropody clinics (Electromedia Model 35F (A), Clean Air Ltd, Scotland, UK). Three clinics were identified, enabling comparison of data between podiatry clinics in the West of Scotland. The sampling was conducted using a portable Surface Air Sampler (Cherwell Laboratories, Bicester, UK). Samples were taken on two days at three different times before and after installation of the filtration units. The global results of the study indicate the filter has a statistically significant effect on microbial counts, with an average percentage decrease of 65%. This study is the first time, to the authors' knowledge, such a system has been tested within podiatric practice.

  1. PROTECTING ECOLOGICAL RESOURCES WITH THE CLEAN AIR ACT: THE ROLE OF SCIENCE

    EPA Science Inventory

    The Clean Air Act provides for establishing National Ambient Air Quality Standards (NAAQS) to protect public welfare (including crops, forests, ecosystems, and soils) from adverse effects of air pollutants, including tropospheric ozone. The formulation of policies is science-base...

  2. Clean Air Slots Amid Atmospheric Pollution

    NASA Technical Reports Server (NTRS)

    Hobbs, Peter V.

    2002-01-01

    Layering in the Earth's atmosphere is most commonly seen where parts of the atmosphere resist the incursion of air parcels from above and below - for example, when there is an increase in temperature with height over a particular altitude range. Pollutants tend to accumulate underneath the resulting stable layers. which is why visibility often increases markedly above certain altitudes. Here we describe the occurrence of an opposite effect, in which stable layers generate a layer of remarkably clean air (we refer to these layers as clean-air 'slots') sandwiched between layers of polluted air. We have observed clean-air slots in various locations around the world, but they are particularly well defined and prevalent in southern Africa during the dry season August-September). This is because at this time in this region, stable layers are common and pollution from biomass burning is widespread.

  3. SURVEY OF AIR AND GAS CLEANING OPERATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgenthaler, A.C.

    1959-09-01

    An informative summary of air and gas cleaning operations in the Chemicai Processing Department of the Hanfor Atomic Products Operation, Richland, Washington, is presented. Descriptlons of the fundamental components of cleaning systems, their applications, and cost information are included. (R.G.G.)

  4. Quantitative Guidance for Stove Usage and Performance to Achieve Health and Environmental Targets.

    PubMed

    Johnson, Michael A; Chiang, Ranyee A

    2015-08-01

    Displacing the use of polluting and inefficient cookstoves in developing countries is necessary to achieve the potential health and environmental benefits sought through clean cooking solutions. Yet little quantitative context has been provided on how much displacement of traditional technologies is needed to achieve targets for household air pollutant concentrations or fuel savings. This paper provides instructive guidance on the usage of cooking technologies required to achieve health and environmental improvements. We evaluated different scenarios of displacement of traditional stoves with use of higher performing technologies. The air quality and fuel consumption impacts were estimated for these scenarios using a single-zone box model of indoor air quality and ratios of thermal efficiency. Stove performance and usage should be considered together, as lower performing stoves can result in similar or greater benefits than a higher performing stove if the lower performing stove has considerably higher displacement of the baseline stove. Based on the indoor air quality model, there are multiple performance-usage scenarios for achieving modest indoor air quality improvements. To meet World Health Organization guidance levels, however, three-stone fire and basic charcoal stove usage must be nearly eliminated to achieve the particulate matter target (< 1-3 hr/week), and substantially limited to meet the carbon monoxide guideline (< 7-9 hr/week). Moderate health gains may be achieved with various performance-usage scenarios. The greatest benefits are estimated to be achieved by near-complete displacement of traditional stoves with clean technologies, emphasizing the need to shift in the long term to near exclusive use of clean fuels and stoves. The performance-usage scenarios are also provided as a tool to guide technology selection and prioritize behavior change opportunities to maximize impact.

  5. Localized removal of layers of metal, polymer, or biomaterial by ultrasound cavitation bubbles

    PubMed Central

    Fernandez Rivas, David; Verhaagen, Bram; Seddon, James R. T.; Zijlstra, Aaldert G.; Jiang, Lei-Meng; van der Sluis, Luc W. M.; Versluis, Michel; Lohse, Detlef; Gardeniers, Han J. G. E.

    2012-01-01

    We present an ultrasonic device with the ability to locally remove deposited layers from a glass slide in a controlled and rapid manner. The cleaning takes place as the result of cavitating bubbles near the deposited layers and not due to acoustic streaming. The bubbles are ejected from air-filled cavities micromachined in a silicon surface, which, when vibrated ultrasonically at a frequency of 200 kHz, generate a stream of bubbles that travel to the layer deposited on an opposing glass slide. Depending on the pressure amplitude, the bubble clouds ejected from the micropits attain different shapes as a result of complex bubble interaction forces, leading to distinct shapes of the cleaned areas. We have determined the removal rates for several inorganic and organic materials and obtained an improved efficiency in cleaning when compared to conventional cleaning equipment. We also provide values of the force the bubbles are able to exert on an atomic force microscope tip. PMID:23964308

  6. EPA evaluates air, water controls

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fairley, P.

    1996-06-05

    Water and air pollution controls make significant contribution to the economy`s health, according to two EPA reports. Clean water provides billions of dollars in benefits to US industries, says a recently released study; and the agency`s draft report on the benefits of air pollution identifiesmore » $$20 in medical costs avoided for every dollar spent on pollution controls. The Clean Water Industry Coalition (CWIC) says the water report reaffirms the need to {open_quotes}modernize{close_quotes} the Clean Water Act (CWA), but EPA administrator Carol Browner says a CWA {open_quotes}rollback{close_quotes} supported by CWIC and passed by House Republicans last May would have jeopardized industries that depend on clean water by weakening effluent standards. Browner denies that the benefits of clean water as identified by the EPA report would have protected water standards from the bill`s cost-benefit requirements. A draft EPA report on clean air leaked by the American Lung Association estimates that tailpipe and smokestack controls for air pollution saved 79,000 lives and resulted in 15 million fewer respiratory illnesses in 1990 alone. The report assesses the costs and benefits of the Clean Air Act from 1970 to 1990. The cost of federal, state, and local regulations were estimated at $$436 billion over the 20-year span, whereas direct benefits of reduced pollution totaled $6.8 trillion.« less

  7. Evaluation of Ultra-Violet Photocatalytic Oxidation (UVPCO) forIndoor Air Applications: Conversion of Volatile Organic Compounds at LowPart-per-Billion Concentrations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hodgson, Alfred T.; Sullivan, Douglas P.; Fisk, William J.

    2005-09-30

    Efficient removal of indoor generated airborne particles and volatile organic compounds (VOCs) in office buildings and other large buildings may allow for a reduction in outdoor air supply rates with concomitant energy savings while still maintaining acceptable indoor air quality in these buildings. Ultra-Violet Photocatalytic Oxidation (UVPCO) air cleaners have the potential to achieve the necessary reductions in indoor VOC concentrations at relatively low cost. In this study, laboratory experiments were conducted with a scaled, prototype UVPCO device designed for use in a duct system. The experimental UVPCO contained two 30 by 30-cm honeycomb monoliths coated with titanium dioxide andmore » 3% by weight tungsten oxide. The monoliths were irradiated with 12 UVC lamps arranged in four banks. The UVPCO was challenged with four mixtures of VOCs typical of mixtures encountered in indoor air. A synthetic office mixture contained 27 VOCs commonly measured in office buildings. A cleaning product mixture contained three cleaning products with high market shares. A building product mixture was created by combining sources including painted wallboard, composite wood products, carpet systems, and vinyl flooring. A fourth mixture contained formaldehyde and acetaldehyde. Steady-state concentrations were produced in a classroom laboratory or a 20-m{sup 3} environmental chamber. Air was drawn through the UVPCO, and single pass conversion efficiencies were measured from replicate air samples collected upstream and downstream of the reactor section. Concentrations of the mixtures were manipulated, with concentrations of individual VOCs mostly maintained below 10 ppb. Device flow rates were varied between 165 and 580 m{sup 3}/h. Production of formaldehyde, acetaldehyde, acetone, formic acid, and acetic acid as reaction products was investigated. Conversion efficiency data were generated for 48 individual VOCs or groups of closely related compounds. Alcohols and glycol ethers were the most reactive chemical classes with conversion efficiencies often near or above 70% at the low flow rate and near 40% at the high flow rate. Ketones and terpene hydrocarbons were somewhat less reactive. The relative VOC conversion rates are generally favorable for treatment of indoor air since many contemporary products used in buildings employ oxygenated solvents. A commercial UVPCO device likely would be installed in the supply air stream of a building and operated to treat both outdoor and recirculated air. Assuming a recirculation rate comparable to three times the normal outdoor air supply rate, simple mass-balance modeling suggests that a device with similar characteristics to the study unit has sufficient conversion efficiencies for most VOCs to compensate for a 50% reduction in outdoor air supply without substantially impacting indoor VOC concentrations. Formaldehyde, acetaldehyde, acetone, formic acid, and acetic acid were produced in these experiments as reaction byproducts. No other significant byproducts were observed. A coupled steady-state mass balance model is presented and applied to VOC data from a study of a single office building. For the operating assumptions described above, the model estimated a three-fold increase in indoor formaldehyde and acetaldehyde concentrations. The outcome of this limited assessment suggests that evaluation of the potential effects of the operation of a UVPCO device on indoor concentrations of these contaminants is warranted. Other suggested studies include determining VOC conversion efficiencies in actual buildings and evaluating changes in VOC conversion efficiency as monoliths age with long-term operation.« less

  8. Webinar: Clean Air in the Classroom: Improve Air Quality, Extend HVAC System Life with Preventive Maintenance

    EPA Pesticide Factsheets

    A page to register to view the May 17, 2018, webinar in the IAQ Knowledge-to-Action Professional Training Webinar Series: Clean Air in the Classroom: Improve Air Quality, Extend HVAC System Life with Preventive Maintenance

  9. 1990 Clean Air Act Amendment Summary: Title VI

    EPA Pesticide Factsheets

    This page provides an overview of the 1990 amendments to Title VI of the Clean Air Act, which were enacted to curb acid rain, urban air pollution and toxic air emissions. The edits to this title deal with stratospheric ozone and global climate protection.

  10. Design Principles for Covalent Organic Frameworks as Efficient Electrocatalysts in Clean Energy Conversion and Green Oxidizer Production.

    PubMed

    Lin, Chun-Yu; Zhang, Lipeng; Zhao, Zhenghang; Xia, Zhenhai

    2017-05-01

    Covalent organic frameworks (COFs), an emerging class of framework materials linked by covalent bonds, hold potential for various applications such as efficient electrocatalysts, photovoltaics, and sensors. To rationally design COF-based electrocatalysts for oxygen reduction and evolution reactions in fuel cells and metal-air batteries, activity descriptors, derived from orbital energy and bonding structures, are identified with the first-principle calculations for the COFs, which correlate COF structures with their catalytic activities. The calculations also predict that alkaline-earth metal-porphyrin COFs could catalyze the direct production of H 2 O 2 , a green oxidizer and an energy carrier. These predictions are supported by experimental data, and the design principles derived from the descriptors provide an approach for rational design of new electrocatalysts for both clean energy conversion and green oxidizer production. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. 78 FR 69709 - Notice of Extension to Public Comment Period for Consent Decree Under the Clean Air Act and the...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-20

    ... Clean Air Act and the Emergency Planning and Community Right- To Know Act'' On September 30, 2013, the... lawsuit filed under the Clean Air Act and the Emergency Planning & Community Right to Know Act, the United... would receive comments concerning the settlement for a period of thirty (30) days from the date of...

  12. 78 FR 45272 - Notice of Lodging of Proposed Third Amendment to Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-26

    ... Decree to provide the Lafarge Companies with an extension of time of until July 1, 2016 to complete... Clean Air Act On July 23, 2013, the Department of Justice lodged a proposed Third Amendment to the... certain violations of the federal Clean Air Act, 42 U.S.C. 7401 et seq. by Lafarge North America, Lafarge...

  13. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14820 How must I monitor opacity for air curtain incinerators that burn 100 percent...

  14. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste...

  15. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste...

  16. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14820 How must I monitor opacity for air curtain incinerators that burn 100 percent...

  17. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14820 How must I monitor opacity for air curtain incinerators that burn 100 percent...

  18. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... percent wood wastes, clean lumber and/or yard waste? (a) After the date the initial test for opacity is...

  19. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... percent wood wastes, clean lumber and/or yard waste? (a) After the date the initial test for opacity is...

  20. 76 FR 10895 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-28

    ... standards, research related to air quality, sources of air pollution, and the strategies to attain and... public health and the environment. EPA's Office of Air and Radiation requested the Ozone Review Panel... a Public Teleconference of the Clean Air Scientific Advisory Committee (CASAC); Ozone Review Panel...

  1. 75 FR 42130 - Notice of Lodging of Consent Decree Under the Clean Air Act; Clean Water Act; Resource...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-20

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act; Clean Water Act; Resource Conservation and Recovery Act; Safe Drinking Water Act; Toxic Substances Control Act; and the Reporting Requirements of the Emergency Planning and Community Right-To-Know Act and the Comprehensive Environmental Response, Compensation, and...

  2. Citizen Science Air Sensor Project with Clean Air Carolina and the Eastern Band of Cherokee Indians Fact Sheet

    EPA Pesticide Factsheets

    EPA scientists are partnering with Clean Air Carolina (CAC) in Charlotte, N.C., and the Eastern Band of Cherokee Indians (EBCI) in Cherokee, N.C., to conduct a citizen science air quality project in these regions.

  3. Air Quality Criteria for Lead (Final Report, 2006)

    EPA Science Inventory

    National Ambient Air Quality Standards (NAAQS) are promulgated by the United States Environmental Protection Agency (EPA) to meet requirements set forth in Sections 108 and 109 of the U.S. Clean Air Act. Those two Clean Air Act sections require the EPA Administrator (1) to list w...

  4. Residual tetrachloroethylene in dry-cleaned clothes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawauchi, T.; Nishiyama, K.

    1989-04-01

    A large amount of residual tetrachloroethylene (TCE), up to 13.6 mg/g, was found in dry-cleaned clothes. The amounts varied among dry-cleaning establishments as well as with the type of fiber. The causes of these variations are discussed. Air TCE concentrations in the closed environment of dry-cleaning outlets were elevated: the highest reading was 4.8 mg/m3. The expired air of outlet employees also showed an increased level of TCE (average, 36.9 micrograms/m3). Increased air contamination from TCE released from dry-cleaned clothes was also observed in the home of a consumer. To reduce environmental contamination from TCE released from any of thesemore » sources, the amount of residual TCE in dry-cleaned clothes should be minimized.« less

  5. Pre-Packaged Commercial PACE Financing Solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wallander, Michael

    The objective of this project was to demonstrate a more streamlined method for facilitating commercial property assessed clean energy (PACE) retrofits. The Recipient aimed to prove that energy efficiency performance of simple, pre-packaged technologies (e.g., lighting and heating, ventilation and air conditioning (HVAC)) can be accurately estimated without the need for a detailed energy audit. A successful project would inspire consumer confidence in undertaking cost-effective retrofits.

  6. Clean Air Act Vehicle and Engine Enforcement Case Resolutions

    EPA Pesticide Factsheets

    The Clean Air Act requires new engines and equipment sold or distributed in the United States to be certified to meet EPA-established emissions requirements to protect public health and the environment from air pollution.

  7. New Jersey: Clean Air Communities (A Former EPA CARE Project)

    EPA Pesticide Factsheets

    Clean Air Communities (CAC) is the recipient of a Level II CARE cooperative agreement to implement recommendations by the state’s Environmental Justice Task Force and the Air Toxics Pilot Project to reduce environmental risks.

  8. Forensic aspects of the aerotoxic syndrome.

    PubMed

    Abeyratne, Ruwantissa

    2002-01-01

    Three decades ago, cabin air quality was seemingly not an issue in commercial aviation and the incidence of disease through air borne vectors or toxic fumes was uncommon among passengers and crew. However, it is claimed that modern day jet airliners generally carry the threat of disease through the ventilator systems of these aircraft which are designed for optimum efficiency, leaving them exposed to lapses in the recycling of clean air and blocking fumes from engine exhausts of the jets from entering the inhabited parts of the aircraft. It has been claimed that aerotoxic fumes are most common in the cockpit, and that the technical crew are the most susceptible to the aerotoxic syndrome.

  9. 40 CFR Appendix A-1 to Part 50 - Reference Measurement Principle and Calibration Procedure for the Measurement of Sulfur Dioxide...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... SO2 from the sampling manifold to provide clean zero air at the output manifold for zero adjustment... Standard Reference Material (SRM). 4.1.6.2 Clean zero air, free of contaminants that could cause a... be sensitive to aromatic hydrocarbons and O2-to-N2 ratios, it is important that the clean zero air...

  10. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2974 Am I required to apply for and obtain a title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber...

  11. 40 CFR 60.2974 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2974 Am I required to apply for and obtain a title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber...

  12. Notification: Background Investigation Services EPA’s Efforts to Incorporate Environmental Justice Into Clean Air Act Inspections for Air Toxics

    EPA Pesticide Factsheets

    Project #OPE-FY14-0017, March 7, 2014. The OIG plans to begin the preliminary research phase of an evaluation of the EPA's efforts to incorporate environmental justice into Clean Air Act (CAA) inspections for air toxics.

  13. Evaluation of HEPA vacuum cleaning and dry steam cleaning in reducing levels of polycyclic aromatic hydrocarbons and house dust mite allergens in carpets

    PubMed Central

    Yu, Chang Ho; Yiin, Lih-Ming; Fan, Zhi-Hua (Tina); Rhoads, George G.

    2014-01-01

    Dry steam cleaning, which has gained recent attention as an effective method to reduce house dust mite (HDM) allergen concentration and loading in carpets, was evaluated in this study for its efficacy in lowering levels of polycyclic aromatic hydrocarbons (PAHs) as well as HDM allergens. Fifty urban homes with wail-to-wall carpets, mostly low-income and with known lead contamination, were studied in 2003 and 2004. Two carpet-cleaning interventions were compared: Repeated HEPA (High Efficiency Particulate Air filtered) vacuuming alone and repeated HEPA vacuuming supplemented with dry steam cleaning. Vacuum samples were collected to measure carpet loading of dust and contaminants immediately before and after cleaning. Paired comparisons were conducted to evaluate the effectiveness of the cleaning protocols in reducing the levels of PAHs and HDM allergens in carpets. The results indicated that both cleaning methods substantially reduced the loading of PAHs and HDM allergens as well as dust in carpets (p < 0.0001). The reductions in loading of dust (64.4%), PAHs (69.1%), and HDM allergens (85.5%), by dry steam cleaning plus repetitive HEPA vacuuming were larger than the reductions by regular HEPA vacuuming alone: dust (55.5%), PAHs (58.6%), and HDM allergens (80.8%), although the difference was statistically significant only for dust and PAHs. We conclude that intensive HEPA vacuum cleaning substantially reduced the loading of PAHs and HDM allergens in carpets in these urban homes and that dry steam cleaning added modestly to cleaning effectiveness. PMID:19137159

  14. Integrating biofiltration with SVE: A case study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lesley, M.P.; Rangan, C.R.

    1996-12-01

    A prototype integrated soil vacuum extraction/biofiltration system has been designed and installed at a gasoline contaminated LUST site in southern Delaware. The prototype system remediates contaminated moisture entrained in the air stream, employs automatic water level controls in the filters, and achieves maximum vapor extraction and VOC destruction efficiency with an optimum power input. In addition, the valving and piping layout allows the direction of air flow through the filters to be reversed at a given time interval, which minimizes biofouling, thereby increasing efficiency by minimizing the need for frequent cleaning. This integrated system achieves constant VOC destruction rates ofmore » 40 to 70% while maintaining optimal VOC removal rates from the subsurface. The modular design allows for easy mobilization, setup and demobilization at state-lead LUST sites throughout Delaware.« less

  15. Low excess air burners keep boiler and air cleaner while cutting fuel costs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Robinson, H.

    1981-11-01

    In the 1970s at the Humko Chemical Co., producers of fatty acids used in plastics, soaps, rubber products, and textiles, it was deemed necessary to modify existing boiler equipment to insure an adequate fuel supply and to increase efficienct. Existing equipment operated at an overall average efficiency of 77% and only 6% excess O/sub 2/ could be achieved with number 6 fuel oil and only 2.6% with natural gas. Cleaning the boilers and replacing existing burners with oil and gas firing units led to overall efficiency up to 84% with only 1% excess O/sub 2/. Even though fuel costs havemore » approximately tripled during the ensuing time, Humko's cost of producing steam has only doubled with the more efficienct equipment. (BLM)« less

  16. 78 FR 42802 - Notice of Lodging of Proposed Consent Decree Under the Clean Water Act, Clean Air Act, and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-17

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Proposed Consent Decree Under the Clean Water Act, Clean Air Act, and Resource Conservation and Recovery Act On July 11, 2013, the Department of Justice lodged a proposed consent decree with the United States District Court for the Western District of Arkansas in the lawsuit entitled United States v....

  17. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  18. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  19. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  20. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  1. 40 CFR 60.3067 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.3067 Section 60.3067... Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3067 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of...

  2. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to...

  3. 40 CFR 62.14820 - How must I monitor opacity for air curtain incinerators that burn 100 percent wood wastes, clean...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? 62.14820 Section... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or... wood wastes, clean lumber, and/or yard waste? (a) Use Method 9 of 40 CFR part 60, Appendix A to...

  4. Air Quality Criteria for Ozone and Related Photochemical ...

    EPA Pesticide Factsheets

    In February 2006, EPA released the final document, Air Quality Criteria for Ozone and Other Photochemical Oxidants. Tropospheric or surface-level ozone (O3) is one of six major air pollutants regulated by National Ambient Air Quality Standards (NAAQS) under the U.S. Clean Air Act. As mandated by the Clean Air Act, the U.S. Environmental Protection Agency (EPA) must periodically review the scientific bases (or criteria) for the various NAAQS by assessing newly available scientific information on a given criteria air pollutant. This document, Air Quality Criteria for Ozone and Other Photochemical Oxidants, is an updated revision of the 1996 Ozone Air Quality Criteria Document (O3 AQCD) that provided scientific bases for the current O3 NAAQS set in 1997. The Clean Air Act mandates periodic review of the National Ambient Air Quality Standards (NAAQS) for six common air pollutants, also referred to as criteria pollutants, including ozone.

  5. PHASE I PILOT AIR CONVEYANCE SYSTEM DESIGN, CLEANING, AND CHARACTERIZATION

    EPA Science Inventory

    The report gives results of a project to develop and refine surface and airborne contamination
    measurement techniques that can be used to evaluate air conveyance system (ACS) cleaning.
    (NOTE: ACS cleaning is advertized to homeowners as a service having a number of benefits...

  6. Section 609 of the Clean Air Act: MVAC

    EPA Pesticide Factsheets

    Fact sheet provides a general overview of EPA regulations under Section 609 of the Clean Air Act, which is focused on preventing the release of refrigerants during the servicing of motor vehicle air-conditioning systems and similar appliances.

  7. Optical remote measurement of toxic gases

    NASA Technical Reports Server (NTRS)

    Grant, W. B.; Kagann, R. H.; McClenny, W. A.

    1992-01-01

    Enactment of the Clean Air Act Amendments (CAAA) of 1990 has resulted in increased ambient air monitoring needs for industry, some of which may be met efficiently using open-path optical remote sensing techniques. These techniques include Fourier transform spectroscopy, differential optical absorption spectroscopy, laser long-path absorption, differential absorption lidar, and gas cell correlation spectroscopy. With this regulatory impetus, it is an opportune time to consider applying these technologies to the remote and/or path-averaged measurement and monitoring of toxic gases covered by the CAAA. This article reviews the optical remote sensing technology and literature for that application.

  8. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... solvent/air interface, the maximum volume of parts that can be cleaned at one time. In most cases, the cleaning capacity is equal to the volume (length times width times height) of the cleaning chamber. Cold... designed to be easily opened and closed without disturbing the vapor zone. Air disturbances include, but...

  9. Applicability Determination Letters for 40 C.F.R. Part 63 Subpart M, National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities

    EPA Pesticide Factsheets

    This pages contains two letters on the applicability of the National Perchloroethylene Air Emission Standards for Dry Cleaning Facilities (40 CFR 63, Subpart M). Both letters clarify what constitutes instillation of a dry cleaning machine.

  10. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  11. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  12. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  13. 40 CFR 63.461 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... the layer of air inside the solvent cleaning machine freeboard located above the solvent/air interface... speed from the initial loading of soiled or wet parts through the removal of the cleaned or dried parts... fresh unused solvent, recycled solvent, or used solvent that has been cleaned of soils (e.g., skimmed of...

  14. Results from Evaluation of Proposed ASME AG-1 Section FI Metal Media Filters - 13063

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilson, John A.; Giffin, Paxton K.; Parsons, Michael S.

    High efficiency particulate air (HEPA) filtration technology is commonly used in Department of Energy (DOE) facilities that require control of radioactive particulate matter (PM) emissions due to treatment or management of radioactive materials. Although HEPA technology typically makes use of glass fiber media, metal and ceramic media filters are also capable of filtering efficiencies beyond the required 99.97%. Sintered metal fiber filters are good candidates for use in DOE facilities due to their resistance to corrosive environments and resilience at high temperature and elevated levels of relative humidity. Their strength can protect them from high differential pressure or pressure spikesmore » and allow for back pulse cleaning, extending filter lifetime. Use of these filters has the potential to reduce the cost of filtration in DOE facilities due to life cycle cost savings. ASME AG-1 section FI has not been approved due to a lack of protocols and performance criteria for qualifying section FI filters. The Institute for Clean Energy Technology (ICET) with the aid of the FI project team has developed a Section FI test stand and test plan capable of assisting in the qualification ASME AG-1 section FI filters. Testing done at ICET using the FI test stand evaluates resistance to rated air flow, test aerosol penetration and resistance to heated air of the section FI filters. Data collected during this testing consists of temperature, relative humidity, differential pressure, flow rate, upstream particle concentration, and downstream particle concentration. (authors)« less

  15. Finding of No Significant Impact: Replacement of Chemical Cleaning Line Tinker Air Force Base Oklahoma City, Oklahoma

    DTIC Science & Technology

    2012-05-01

    indoor air quality from installation of a new, improved cleaning line ventilation system. Cultural Resources No adverse effect on cultural...EA) has been prepared to assess the potential effects on the human and natural environment of replacing the chemical cleaning line at Tinker Air...providing improved system monitors and controls, reducing the overall energy consumption of the system, and enabling the system to accommodate larger

  16. 3 CFR - State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 3 The President 1 2010-01-01 2010-01-01 false State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act Presidential Documents Other Presidential Documents Memorandum of January 26, 2009 State of California Request for Waiver Under 42 U.S.C. 7543(b), the Clean Air Act Memorandum for the Administrator of the Environmental...

  17. Method of and apparatus for preheating pressurized fluidized bed combustor and clean-up subsystem of a gas turbine power plant

    DOEpatents

    Cole, Rossa W.; Zoll, August H.

    1982-01-01

    In a gas turbine power plant having a pressurized fluidized bed combustor, gas turbine-air compressor subsystem and a gas clean-up subsystem interconnected for fluid flow therethrough, a pipe communicating the outlet of the compressor of the gas turbine-air compressor subsystem with the interior of the pressurized fluidized bed combustor and the gas clean-up subsystem to provide for flow of compressed air, heated by the heat of compression, therethrough. The pressurized fluidized bed combustor and gas clean-up subsystem are vented to atmosphere so that the heated compressed air flows therethrough and loses heat to the interior of those components before passing to the atmosphere.

  18. Determinants of Wood Dust Exposure in the Danish Furniture Industry—Results from Two Cross-Sectional Studies 6 Years Apart

    PubMed Central

    Schlünssen, Vivi; Jacobsen, Gitte; Erlandsen, Mogens; Mikkelsen, Anders B.; Schaumburg, Inger; Sigsgaard, Torben

    2008-01-01

    Objectives: This paper investigates determinants of wood dust exposure and trends in dust level in the furniture industry of Viborg County, Denmark, using data from two cross-sectional studies 6 years apart. Methods: During the winter 1997/1998, 54 factories were visited (hereafter study 1). In the winter 2003/2004, 27 factories were revisited, and personal dust measurements were repeated. In addition, 14 new factories were included (hereafter study 2). A total of 2303 woodworkers participated in study 1, and 2358 measurements from 1702 workers were available. From study 2, 1581 woodworkers participated and 1355 measurements from 1044 workers were available. Information on occupational variables describing potential determinants of exposures like work task, exhaust ventilation, enclosure and cleaning procedures were collected. A total of 2627 measurements and 1907 persons were included in the final mixed model in order to explore determinants of exposure and trends in dust level. Results: The overall inhalable wood dust concentration (geometric means (geometric standard deviation)) has decreased from 0.95 mg/m3 (2.05) in study 1 to 0.60 mg/m3 (1.63) in study 2, representing a 7% annual decrease in dust concentration, which was confirmed in the mixed model. From study 1 to study 2 there has been a change towards less manual work and more efficient cleaning methods, but on the contrary also more inadequate exhaust ventilation systems. The following determinants were found to ‘increase’ dust concentration: sanding; use of compressed air; use of full-automatic machines; manual work; cleaning of work pieces with compressed air; kitchen producing factories and small factories (<20 employees). The following determinants of exposure were found to ‘decrease’ dust concentration: manual assembling/packing; sanding with adequate exhaust ventilation; adequate exhaust ventilation; vacuum cleaning of machines and special cleaning staff. Conclusions: Despite a substantial drop in the dust concentration during the last 6 years in the furniture industry in Viborg County, further improvements are possible. There should be more focus on improved exhaust ventilation, professional cleaning methods and avoiding use of compressed air. PMID:18407937

  19. Determinants of wood dust exposure in the Danish furniture industry--results from two cross-sectional studies 6 years apart.

    PubMed

    Schlünssen, Vivi; Jacobsen, Gitte; Erlandsen, Mogens; Mikkelsen, Anders B; Schaumburg, Inger; Sigsgaard, Torben

    2008-06-01

    This paper investigates determinants of wood dust exposure and trends in dust level in the furniture industry of Viborg County, Denmark, using data from two cross-sectional studies 6 years apart. During the winter 1997/1998, 54 factories were visited (hereafter study 1). In the winter 2003/2004, 27 factories were revisited, and personal dust measurements were repeated. In addition, 14 new factories were included (hereafter study 2). A total of 2303 woodworkers participated in study 1, and 2358 measurements from 1702 workers were available. From study 2, 1581 woodworkers participated and 1355 measurements from 1044 workers were available. Information on occupational variables describing potential determinants of exposures like work task, exhaust ventilation, enclosure and cleaning procedures were collected. A total of 2627 measurements and 1907 persons were included in the final mixed model in order to explore determinants of exposure and trends in dust level. The overall inhalable wood dust concentration (geometric means (geometric standard deviation)) has decreased from 0.95 mg/m(3) (2.05) in study 1 to 0.60 mg/m(3) (1.63) in study 2, representing a 7% annual decrease in dust concentration, which was confirmed in the mixed model. From study 1 to study 2 there has been a change towards less manual work and more efficient cleaning methods, but on the contrary also more inadequate exhaust ventilation systems. The following determinants were found to 'increase' dust concentration: sanding; use of compressed air; use of full-automatic machines; manual work; cleaning of work pieces with compressed air; kitchen producing factories and small factories (<20 employees). The following determinants of exposure were found to 'decrease' dust concentration: manual assembling/packing; sanding with adequate exhaust ventilation; adequate exhaust ventilation; vacuum cleaning of machines and special cleaning staff. Despite a substantial drop in the dust concentration during the last 6 years in the furniture industry in Viborg County, further improvements are possible. There should be more focus on improved exhaust ventilation, professional cleaning methods and avoiding use of compressed air.

  20. 75 FR 31290 - Approval and Promulgation of State Implementation Plan Revisions; State of North Dakota; Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-03

    ... Interstate Transport of Pollution for the 1997 PM 2.5 and 8-Hour Ozone NAAQS: ``Significant Contribution to... Transport of Air Pollution'' addressing the requirements of Clean Air Act section 110(a)(2)(D)(i) for the... to as the Interstate Transport of Air Pollution SIP, address the requirements of Clean Air Act...

  1. [Analysis and research on cleaning points of HVAC systems in public places].

    PubMed

    Yang, Jiaolan; Han, Xu; Chen, Dongqing; Jin, Xin; Dai, Zizhu

    2010-03-01

    To analyze cleaning points of HVAC systems, and to provides scientific base for regulating the cleaning of HVAC systems. Based on the survey results on the cleaning situation of HVAC systems around China for the past three years, we analyzes the cleaning points of HVAC systems from various aspects, such as the major health risk factors of HVAC systems, the formulation strategy of the cleaning of HVAC systems, cleaning methods and acceptance points of the air ducts and the parts of HVAC systems, the onsite protection and individual protection, the waste treatment and the cleaning of the removed equipment, inspection of the cleaning results, video record, and the final acceptance of the cleaning. The analysis of the major health risk factors of HVAC systems and the formulation strategy of the cleaning of HVAC systems is given. The specific methods for cleaning the air ducts, machine units, air ports, coil pipes and the water cooling towers of HVAC systems, the acceptance points of HVAC systems and the requirements of the report on the final acceptance of the cleaning of HVAC systems are proposed. By the analysis of the points of the cleaning of HVAC systems and proposal of corresponding measures, this study provides the base for the scientific and regular launch of the cleaning of HVAC systems, a novel technology service, and lays a foundation for the revision of the existing cleaning regulations, which may generate technical and social benefits to some extent.

  2. 78 FR 70960 - Notice of Lodging of Consent Decree Under the Clean Air Act, Clean Water Act, and the Resource...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-27

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act, Clean Water Act, and the Resource Conservation and Recovery Act On November 20, 2013, the Department of Justice lodged a proposed consent decree with the United States District Court for the Central District of Illinois in the lawsuit entitled United States v....

  3. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  4. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  5. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  6. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  7. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  8. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... Only Wood Waste, Clean Lumber, and Yard Waste § 60.2972 How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  9. 40 CFR 60.3063 - When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... incinerator burns only wood waste, clean lumber, and yard waste? 60.3063 Section 60.3063 Protection of... Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3063 When must I comply if my air curtain incinerator burns only wood waste, clean lumber, and yard waste? Table 1 of this subpart specifies the final...

  10. Ozone Control Strategies | Ground-level Ozone | New ...

    EPA Pesticide Factsheets

    2017-09-05

    The Air Quality Planning Unit's primary goal is to protect your right to breathe clean air. Guided by the Clean Air Act, we work collaboratively with states, communities, and businesses to develop and implement strategies to reduce air pollution from a variety of sources that contribute to the ground-level ozone or smog problem.

  11. Notification: Background Investigation Services New Assignment Notification: EPA’s Efforts to Incorporate Environmental Justice Into Clean Air Act Inspections for Air Toxics

    EPA Pesticide Factsheets

    The purpose of this memorandum is to notify you that the EPA OIG plans to begin the preliminary research phase of an evaluation of the U.S. EPA's efforts to incorporate environmental justice into Clean Air Act inspections for air toxics.

  12. Source attribution and mitigation strategies for air pollution in Delhi

    NASA Astrophysics Data System (ADS)

    Kiesewetter, Gregor; Purohit, Pallav; Schoepp, Wolfgang; Liu, Jun; Amann, Markus; Bhanarkar, Anil

    2017-04-01

    Indian cities, and the megacity of Delhi in particular, have suffered from high air pollution for years. Recent observations show that ambient concentrations of fine particulate matter (PM2.5) in Delhi strongly exceed the Indian national ambient air quality standards as well as the World Health Organization's interim target levels. At the same time, India is experiencing strong urbanization, and both Delhi's emissions as well as the exposed population are growing. Therefore the question arises how PM2.5 concentrations will evolve in the future, and how they can be improved efficiently. In the past, typical responses of the Delhi government to high pollution episodes have been restrictions on motorized road traffic, on power plant operations and on construction activities. However, to design sustainable and efficient pollution mitigation measures, the contribution of different source sectors and spatial scales needs to be quantified. Here we combine the established emission calculation scheme of the Greenhouse Gas - Air Pollution Interactions and Synergies (GAINS) model with regional chemistry-transport model simulations (0.5° resolution) as well as local particle dispersion (2 × 2 km resolution) to arrive at a source attribution of ambient PM2.5 in Delhi. Calculated concentrations compare well to observations. We find that roughly 60% of total population-weighted PM2.5 originates from sources outside the national capital territory of Delhi itself. Consequently, mitigation strategies need to involve neighboring states and address the typical sources there. We discuss the likely evolution of ambient concentrations under different scenarios which assume either current emission control legislation, or application of a Clean Air Scenario foreseeing additional regulations in non-industrial sectors which are often overlooked, such as phase-out of solid fuel cookstoves, and road paving. Only in the case where the Clean Air Scenario is applied both in Delhi as well as in surrounding states, a strong reduction in ambient concentrations is envisaged which would bring PM2.5 levels close to the WHO interim targets.

  13. Effect of cleaning methods after reduced-pressure air abrasion on bonding to zirconia ceramic.

    PubMed

    Attia, Ahmed; Kern, Matthias

    2011-12-01

    To evaluate in vitro the influence of different cleaning methods after low-pressure air abrasion on the bond strength of a phosphate monomer-containing luting resin to zirconia ceramic. A total of 112 zirconia ceramic disks were divided into 7 groups (n = 16). In the test groups, disks were air abraded at low pressure (L) 0.05 MPa using 50-μm alumina particles. Prior to bonding, the disks were ultrasonically (U) cleaned either in isopropanol alcohol (AC), hydrofluoric acid (HF), demineralized water (DW), or tap water (TW), or they were used without ultrasonic cleaning. Disks air abraded at a high (H) pressure of 0.25 MPa and cleaned ultrasonically in isopropanol served as positive control; original (O) milled disks used without air abrasion served as the negative control group. Plexiglas tubes filled with composite resin were bonded with the adhesive luting resin Panavia 21 to the ceramic disks. Prior to testing tensile bond strength (TBS), each main group was further subdivided into 2 subgroups (n=8) which were stored in distilled water either at 37°C for 3 days or for 30 days with 7500 thermal cycles. Statistical analyses were conducted with two- and one-way analyses of variance (ANOVA) and Tukey's HSD test. Initial tensile bond strength (TBS) ranged from 32.6 to 42.8 MPa. After 30 days storage in water with thermocycling, TBS ranged from 21.9 to 36.3 MPa. Storage in water and thermocycling significantly decreased the TBS of test groups which were not air abraded (p = 0.05) or which were air abraded but cleaned in tap water (p = 0.002), but not the TBS of the other groups (p > 0.05). Also, the TBS of air-abraded groups were significantly higher than the TBS of the original milled (p < 0.01). Cleaning procedures did not significantly affect TBS either after 3 days or 30 days storage in water and thermocycling (p > 0.05). Air abrasion at 0.05 MPa and ultrasonic cleaning are important factors for improving bonding to zirconia ceramic.

  14. Self-Cleaning Boudouard Reactor for Full Oxygen Recovery from CO2 Project

    NASA Technical Reports Server (NTRS)

    Zeitlin, Nancy; Muscatello, Anthony

    2015-01-01

    Oxygen recovery from respiratory CO2 is an important aspect of human spaceflight. Methods exist to sequester the CO2, but production of oxygen needs further development. The current ISS Carbon Dioxide Reduction System (CRS) uses the Sabatier reaction to produce water (and ultimately breathing air). Oxygen recovery is limited to 50% because half of the hydrogen used in the Sabatier reactor is lost as methane, which is vented overboard. The Bosch reaction is the only real alternative to the Sabatier reaction, but in the last reaction in the cycle (Boudouard) the resulting carbon buildup will eventually foul the nickel or iron catalyst, reducing reactor life and increasing consumables. To minimize this fouling, find a use for this waste product, and increase efficiency, we propose testing various self-cleaning catalyst designs in an existing MSFC Boudouard reaction test bed and to determine which one is the most reliable in conversion and lack of fouling. Challenges include mechanical reliability of the cleaning method and maintaining high conversion efficiency with lower catalyst surface area. The above chemical reactions are well understood, but planned implementations are novel (TRL 2) and haven't been investigated at any level.

  15. 40 CFR 61.147 - Standard for fabricating.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... dust deposits on the clean side of bags. For air cleaning devices that cannot be inspected on a weekly... Section 61.147 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos...

  16. 40 CFR 61.147 - Standard for fabricating.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... dust deposits on the clean side of bags. For air cleaning devices that cannot be inspected on a weekly... Section 61.147 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) NATIONAL EMISSION STANDARDS FOR HAZARDOUS AIR POLLUTANTS National Emission Standard for Asbestos...

  17. Westinghouse to launch coal gasifier with combined cycle unit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stavsky, R.M.; Margaritis, P.J.

    1980-03-01

    Following an extensive test program with a prototype coal gasifier, Westinghouse Electric Corp. is now offering an integrated gasifier/combined-cycle unit as a feasible alternative for generating power from coal in an efficient, clean manner. The Westinghouse gasification process uses a single-stage pressurized fluidized-bed reactor, followed by heat recovery, gas cleaning, sulfur and amonia removal and recovery, and gas reheat. The system produces a fuel gas free of sulfur and other contaminants from crushed run-of-mine coals of varying reactivities and caking properties. The by-products include ammonia and sulfur and an agglomerated ash residue that serves as an acceptable landfill. Air formore » the gasifier is bled from the gas-turbine air compressor and further pressurized with a booster compressor. The hot exhaust gases from the gas turbine pass through a heat-recovery steam generator that produces sufficient steam to drive a turbine providing about 40% of the total electricity generated in the plant.« less

  18. Flue gas conditioning today

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Southam, B.J.; Coe, E.L. Jr.

    1995-12-01

    Many relatively small electrostatic precipitators (ESP`s) exist which collect fly ash at remarkably high efficiencies and have been tested consistently at correspondingly high migration velocities. But the majority of the world`s coal supplies produce ashes which are collected at much lower migration velocities for a given efficiency and therefore require correspondingly large specific collection areas to achieve acceptable results. Early trials of flue gas conditioning (FGC) showed benefits in maximizing ESP performance and minimizing expense which justified continued experimentation. Trials of several dozen ways of doing it wrong eventually developed a set of reliable rules for doing it right. Onemore » result is that the use of sulfur trioxide (SO{sub 3}) for adjustment of the resistivity of fly ash from low sulfur coal has been widely applied and has become an automatically accepted part of the option of burning low sulfur coal for compliance with the Clean Air Act of l990 in the U.S.A. Currently, over 100,000 MW of generating capacity is using FGC, and it is estimated that approximately 45,800 MW will utilize coal-switching with FGC for Clean Air Act emission compliance. Guarantees that this equipment will be available to operate at least 98 percent of the time it is called upon are routinely fulfilled.« less

  19. Technologies for Humans in Space with Terrestrial Application for Testing in :envihab

    NASA Astrophysics Data System (ADS)

    Belz, Stefan; Henn, Norbert

    Technologies for humans in space and for a sustainable resource management on Earth are faced to similar recycling challenges. The main differences between life support systems (LSS) in human spaceflight and Earth’s environment are the buffer capacities and enormous diversity of material and organisms in Earth. Thus, LSS in space as a small-scale set-up show quickly the problems of artificial cycle management. Such a cycle management becomes more and more important with increase on world’s population and enlargement of (mega-)cities, in order to provide clean air, clean water and no wasting the environment. There is a need of technologies on Earth and for crewed long-term missions in space focusing on efficient and clean electricity generation, as well as on air, water, food, and waste management at lowest power demand. Existing technologies shall be adapted, and new technologies shall be developed for enhancing quality of life on Earth. The poster demonstrates some significant activities in Germany in the field of air revitalization, biomass and food production by microalgae cultivation, biological water regeneration, synergetic use of fuel cells and electrolyzers, respectively hydrogen and oxygen, in life support and energy systems. These technologies make a strong contribution to higher cycle closures, especially combined in an overall system configuration. The facility of :envihab (Environment and Habitat) in Cologne/Germany enables a unique testbed for integrative experiments from component level to system level, in order to demonstrate and investigate compatibilities, required peripherals devices and diagnostic tools.

  20. Advanced air distribution: improving health and comfort while reducing energy use.

    PubMed

    Melikov, A K

    2016-02-01

    Indoor environment affects the health, comfort, and performance of building occupants. The energy used for heating, cooling, ventilating, and air conditioning of buildings is substantial. Ventilation based on total volume air distribution in spaces is not always an efficient way to provide high-quality indoor environments at the same time as low-energy consumption. Advanced air distribution, designed to supply clean air where, when, and as much as needed, makes it possible to efficiently achieve thermal comfort, control exposure to contaminants, provide high-quality air for breathing and minimizing the risk of airborne cross-infection while reducing energy use. This study justifies the need for improving the present air distribution design in occupied spaces, and in general the need for a paradigm shift from the design of collective environments to the design of individually controlled environments. The focus is on advanced air distribution in spaces, its guiding principles and its advantages and disadvantages. Examples of advanced air distribution solutions in spaces for different use, such as offices, hospital rooms, vehicle compartments, are presented. The potential of advanced air distribution, and individually controlled macro-environment in general, for achieving shared values, that is, improved health, comfort, and performance, energy saving, reduction of healthcare costs and improved well-being is demonstrated. Performance criteria are defined and further research in the field is outlined. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  1. Cleaning devices

    NASA Technical Reports Server (NTRS)

    Schneider, Horst W. (Inventor)

    1981-01-01

    Cleaning devices are described which include a vacuum cleaner nozzle with a sharp rim for directing incoming air down against the floor; a vacuum cleaner wherein electrostatically charged brushes that brush dirt off a floor, are electrically grounded to remove charges that could tend to hold dirt to the brushes; a vacuum cleaner head having slots that form a pair of counter-rotating vortices, and that includes an outlet that blows a stream of air at the floor region which lies between the vortices; a cleaning device that sweeps a group of brushes against the ground along a first direction, and then sweeps them along the same ground area but in a second direction angled from the first by an amount such as 90.degree., to sweep up particles lying in crevices extending along any direction; a device that gently cleans a surface to remove bacteria for analysis, including an inclined wall along which cleaning fluid flows onto the surface, a vacuum chamber for drawing in the cleaning fluid, and a dividing wall spaced slightly from the surface to separate the fluid source from the vacuum cleaner chamber; and a device for providing pulses of pressured air including a chamber to which pressured air is supplied, a ball that circulates around the chamber to repeatedly close an outlet, and an air source that directs air circumferentially to move the ball around the chamber.

  2. Enhanced xylene removal by photocatalytic oxidation using fiber-illuminated honeycomb reactor at ppb level.

    PubMed

    Wu, Yi-Ting; Yu, Yi-Hui; Nguyen, Van-Huy; Lu, Kung-Te; Wu, Jeffrey Chi-Sheng; Chang, Luh-Maan; Kuo, Chi-Wen

    2013-11-15

    The removal of volatile organic compounds (VOCs) at ppb level is one of the most critical challenges in clean rooms for the semiconductor industry. Photocatalytic oxidation is an innovative and promising technology for ppb-level VOCs degradation. We have designed a fiber-illuminated honeycomb reactor (FIHR) in which the removal efficiency of m-xylene is significantly enhanced to 96.5% as compared to 22.0% for UV irradiation only. The results indicate that photocatalysts not only play the role to substantially oxidize m-xylene, but also alter the chemical properties of xylene under UV illumination. Using the FIHR with Mn-TiO2 photocatalyst not only increased the m-xylene removal efficiency, but also increased the CO2 selectivity. Interestingly, Mn-TiO2 in FIHR also showed a very good reusability, 93% removal efficiency was still achieved in 72-h in reaction. Thus, the FIHR gave very high removal efficiency for xylene at ppb level under room temperature. The FIHR has great potential application in the clean room for the air purification system in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  3. KENNEDY SPACE CENTER, FLA. - A KSC employee uses a clean-air shower before entering a clean room. Streams of pressurized air directed at the occupant from nozzles in the chamber's ceiling and walls are designed to dislodge particulate matter from hair, clothing and shoes. The adhesive mat on the floor captures soil from shoe soles, as well as particles that fall on its surface. Particulate matter has the potential to contaminate the space flight hardware being stored or processed in the clean room. The shower is part of KSC's Foreign Object Debris (FOD) control program, an important safety initiative.

    NASA Image and Video Library

    2003-08-29

    KENNEDY SPACE CENTER, FLA. - A KSC employee uses a clean-air shower before entering a clean room. Streams of pressurized air directed at the occupant from nozzles in the chamber's ceiling and walls are designed to dislodge particulate matter from hair, clothing and shoes. The adhesive mat on the floor captures soil from shoe soles, as well as particles that fall on its surface. Particulate matter has the potential to contaminate the space flight hardware being stored or processed in the clean room. The shower is part of KSC's Foreign Object Debris (FOD) control program, an important safety initiative.

  4. Progress Cleaning the Air: Voluntary Partnership Program Accomplishments

    EPA Pesticide Factsheets

    EPA voluntary clean air partnership programs work in tandem with regulatory programs to protect public health and the environment. This page highlights accomplishments of selected partnership programs.

  5. 75 FR 10503 - Notice of Lodging of Consent Decree Under the Clean Air Act, the Clean Water Act, the Emergency...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-08

    ... Decree (``Decree'') in United States v. AES Thames, LLC, Civil Action No. 3:10cv281, was lodged with the... States against AES Thames, LLC under the Clean Air Act, 42 U.S.C. 7401-7671q, the Clean Water Act, 33 U.S... injunctive relief and recovery of civil penalties in connection with AES Thames, LLC's operation of a coal...

  6. Clean Air Act : historical information on EPA's process for reviewing California waiver requests and making waiver determinations

    DOT National Transportation Integrated Search

    2009-01-01

    Emissions from mobile sources, such as automobiles and trucks, contribute to air quality degradation and can threaten public health and the environment. Under the Clean Air Act, the Environmental Protection Agency (EPA) regulates these emissions. The...

  7. Clean Air Act : historical information on EPA's process for reviewing California waiver requests and making waiver determinations.

    DOT National Transportation Integrated Search

    2009-01-16

    Emissions from mobile sources, such as automobiles and trucks, contribute to air : quality degradation and can threaten public health and the environment. Under the : Clean Air Act, the Environmental Protection Agency (EPA) regulates these emissions....

  8. Clean Air Act : historical information on EPA's process for reviewing California waiver requests and making waiver determinations

    DOT National Transportation Integrated Search

    2009-01-16

    Emissions from mobile sources, such as automobiles and trucks, contribute to air quality degradation and can threaten public health and the environment. Under the Clean Air Act, the Environmental Protection Agency (EPA) regulates these emissions. The...

  9. Clean Air Markets - Compliance Query Wizard

    EPA Pesticide Factsheets

    The Compliance Query Wizard is part of a suite of Clean Air Markets-related tools that are accessible at http://ampd.epa.gov/ampd/. The Compliance module provides final compliance results. Using the Compliance Query Wizard, the user can find compliance information associated with specific programs, facilities, states or time frames. Quick Reports and Prepackaged Datasets are also available for data that are commonly requested. Final compliance results are available for all years since 1995 for the Acid Rain Program and for the various NOx trading programs EPA has operated since 1999.EPA's Clean Air Markets Division (CAMD) includes several market-based regulatory programs designed to improve air quality and ecosystems. The most well-known of these programs are EPA's Acid Rain Program and the NOx Programs, which reduce emissions of sulfur dioxide (SO2) and nitrogen oxides (NOx)-compounds that adversely affect air quality, the environment, and public health. CAMD also plays an integral role in the development and implementation of the Clean Air Interstate Rule (CAIR).

  10. Clean Air Markets - Allowances Query Wizard

    EPA Pesticide Factsheets

    The Allowances Query Wizard is part of a suite of Clean Air Markets-related tools that are accessible at http://camddataandmaps.epa.gov/gdm/index.cfm. The Allowances module allows the user to view allowance data associated with EPA's emissions trading programs. Allowance data can be specified and organized using the Allowance Query Wizard to find allowances information associated with specific accounts, companies, transactions, programs, facilities, representatives, allowance type, or by date. Quick Reports and Prepackaged Datasets are also available for data that are commonly requested.EPA's Clean Air Markets Division (CAMD) includes several market-based regulatory programs designed to improve air quality and ecosystems. The most well-known of these programs are EPA's Acid Rain Program and the NOx Programs, which reduce emissions of sulfur dioxide (SO2) and nitrogen oxides (NOx)-compounds that adversely affect air quality, the environment, and public health. CAMD also plays an integral role in the development and implementation of the Clean Air Interstate Rule (CAIR).

  11. Clean Air Markets - Quick Facts and Trends

    EPA Pesticide Factsheets

    The Quick Facts and Trends module is part of a suite of Clean Air Markets-related tools that are accessible at http://camddataandmaps.epa.gov/gdm/index.cfm. The Quick Facts and Trends module provides charts and graphs depicting national trends in emissions and heat input. The user can view, for example, data pertaining to the top annual and ozone season emitters of a selected pollutant, the number of units and facilities in a particular state, and trends in sulfur dioxide, nitrogen oxide and carbon dioxide emissions.EPA's Clean Air Markets Division (CAMD) includes several market-based regulatory programs designed to improve air quality and ecosystems. The most well-known of these programs are EPA's Acid Rain Program and the NOx Programs, which reduce emissions of sulfur dioxide (SO2) and nitrogen oxides (NOx)-compounds that adversely affect air quality, the environment, and public health. CAMD also plays an integral role in the development and implementation of the Clean Air Interstate Rule (CAIR).

  12. 77 FR 44544 - Approval and Promulgation of Air Quality Implementation Plans; Utah; Determination of Clean Data...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-30

    ... governments or preempt Tribal law. List of Subjects in 40 CFR Part 52 Environmental protection, Air pollution... Promulgation of Air Quality Implementation Plans; Utah; Determination of Clean Data for the 1987 PM 10 Standard... National Ambient Air Quality Standard (NAAQS) for particulate matter with an aerodynamic diameter of less...

  13. 78 FR 2333 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Asbestos...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-11

    ...] Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Asbestos Management...-Sw 2100: Management and Control of Asbestos Disposal Sites Not Operated after July 9, 1981,'' and the amended ``Env-A 1801-1807.01: Asbestos Management and Control,'' (amended Asbestos Management Rules) in...

  14. 78 FR 2362 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Asbestos...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-11

    ...] Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants: Asbestos Management... ``Env-Sw 2100: Management and Control of Asbestos Disposal Sites not Operated after July 9, 1981,'' and the amended ``Env-A 1801-1807.01: Asbestos Management and Control'' (amended Asbestos Management Rules...

  15. 75 FR 37794 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-30

    ... the Second Section 812 Prospective Benefit-Cost Study of the Clean Air Act. DATES: The AQMS will... particulate matter (PM 2.5 ) emissions and air quality changes for the Second Section 812 Benefit-Cost... Clean Air Act Amendments (CAAA), EPA conducts periodic studies to assess benefits and costs of programs...

  16. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  17. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  18. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  19. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  20. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2973 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  1. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  2. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  3. 75 FR 32857 - Approval and Promulgation of Air Quality Implementation Plans; Virginia; Revision to Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-10

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 52 [EPA-R03-OAR-2009-0599; FRL-9125-2] Approval and Promulgation of Air Quality Implementation Plans; Virginia; Revision to Clean Air Interstate Rule Sulfur Dioxide Trading Program Correction In final rule document 2010-5105 beginning on page 11738 in the issue...

  4. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  5. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  6. 40 CFR 60.3068 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3068 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  7. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2973 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  8. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Qualification Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.2973 What are the recordkeeping and reporting requirements for air curtain incinerators that burn only wood...

  9. 40 CFR 62.14825 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn 100...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... reporting requirements for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or... Commenced Construction On or Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood... for air curtain incinerators that burn 100 percent wood wastes, clean lumber, and/or yard waste? (a...

  10. Senate passes clean air bill

    NASA Astrophysics Data System (ADS)

    In an 89 to 11 vote the Senate passed a clean air bill aimed at reducing pollution by the turn of the century by imposing tougher controls on American industry. The bill is the first revision of the Clean Air Act of 1970 in 13 years and calls for new limits on auto pollution to clean up smog in most U.S. cities, decreasing by half emissions by power plants that cause acid rain to protect the ecology, and increasing technological controls on factories to protect against cancer-causing and toxic substances. The bill will add about $20 billion per year to the estimated $33 billion cost of complying with current pollution laws.

  11. Photocatalytic air purifiers for indoor air: European standard and pilot room experiments.

    PubMed

    Costarramone, N; Cantau, C; Desauziers, V; Pécheyran, C; Pigot, T; Lacombe, S

    2017-05-01

    At the European level (CEN/TC386), some efforts are currently devoted to new standards for comparing the efficiency of commercial photocatalytic material/devices in various application fields. Concerning prototype or commercial indoor photocatalytic air purifiers designed for volatile organic compounds (VOC) abatement, the methodology is based on a laboratory airtight chamber. The photocatalytic function is demonstrated by the mineralization of a mixture of five VOCs. Experimental data were obtained for four selected commercial devices and three commercial materials: drop of VOC concentration, but also identification of secondary species (with special attention to formaldehyde), mineralization rates, and Clean Air Delivery Rate (CADR). With two efficient air purifiers, these laboratory experiments were compared to the results in two experimental rooms (35-40 m 3 ) where air pollution was introduced through wooden floor and furniture. The systems' ageing was also studied. The safety of the commercial products was also assessed by the determination of nanoparticle release. Standardized tests are useful to rank photocatalytic air purifiers and passive materials and to discard inefficient ones. A good correlation between the standard experiments and the experimental room experiments was found, even if in the latter case, the concentration of lower weight VOCs drops less quickly than that of heavier VOCs.

  12. CPICOR{trademark}: Clean power from integrated coal-ore reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wintrell, R.; Miller, R.N.; Harbison, E.J.

    1997-12-31

    The US steel industry, in order to maintain its basic iron production, is thus moving to lower coke requirements and to the cokeless or direct production of iron. The US Department of Energy (DOE), in its Clean Coal Technology programs, has encouraged the move to new coal-based technology. The steel industry, in its search for alternative direct iron processes, has been limited to a single process, COREX{reg_sign}. The COREX{reg_sign} process, though offering commercial and environmental acceptance, produces a copious volume of offgas which must be effectively utilized to ensure an economical process. This volume, which normally exceeds the internal needsmore » of a single steel company, offers a highly acceptable fuel for power generation. The utility companies seeking to offset future natural gas cost increases are interested in this clean fuel. The COREX{reg_sign} smelting process, when integrated with a combined cycle power generation facility (CCPG) and a cryogenic air separation unit (ASU), is an outstanding example of a new generation of environmentally compatible and highly energy efficient Clean Coal Technologies. This combination of highly integrated electric power and hot metal coproduction, has been designated CPICOR{trademark}, Clean Power from Integrated Coal/Ore Reduction.« less

  13. Airborne exposures to monoethanolamine, glycol ethers, and benzyl alcohol during professional cleaning: a pilot study.

    PubMed

    Melchior Gerster, Fabian; Brenna Hopf, Nancy; Pierre Wild, Pascal; Vernez, David

    2014-08-01

    A growing body of epidemiologic evidence suggests an association between exposure to cleaning products and respiratory dysfunction. Due to the lack of quantitative assessments of respiratory exposures to airborne irritants and sensitizers among professional cleaners, the culpable substances have yet to be identified. Focusing on previously identified irritants, our aims were to determine (i) airborne concentrations of monoethanolamine (MEA), glycol ethers, and benzyl alcohol (BA) during different cleaning tasks performed by professional cleaning workers and assess their determinants; and (ii) air concentrations of formaldehyde, a known indoor air contaminant. Personal air samples were collected in 12 cleaning companies, and analyzed by conventional methods. Nearly all air concentrations [MEA (n = 68), glycol ethers (n = 79), BA (n = 15), and formaldehyde (n = 45)] were far below (<1/10) of the corresponding Swiss occupational exposure limits (OEL), except for ethylene glycol mono-n-butyl ether (EGBE). For butoxypropanol and BA, no OELs exist. Although only detected once, EGBE air concentrations (n = 4) were high (49.48-58.72mg m(-3)), and close to the Swiss OEL (49mg m(-3)). When substances were not noted as present in safety data sheets of cleaning products used but were measured, air concentrations showed no presence of MEA, while the glycol ethers were often present, and formaldehyde was universally detected. Exposure to MEA was affected by its amount used (P = 0.036), and spraying (P = 0.000) and exposure to butoxypropanol was affected by spraying (P = 0.007) and cross-ventilation (P = 0.000). Professional cleaners were found to be exposed to multiple airborne irritants at low concentrations, thus these substances should be considered in investigations of respiratory dysfunctions in the cleaning industry; especially in specialized cleaning tasks such as intensive floor cleaning. © The Author 2014. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  14. Clean Air Slots Amid Dense Atmospheric Pollution in Southern Africa

    NASA Technical Reports Server (NTRS)

    Hobbs, Peter V.

    2003-01-01

    During the flights of the University of Washington's Convair-580 in the Southern African Regional Science Initiative (SAFARI 2000) in southern Africa, a phenomenon was observed that has not been reported previously. This was the occurrence of thin layers of remarkably clean air, sandwiched between heavily polluted air, which persisted for many hours during the day. Photographs are shown of these clean air slots (CAS), and particle concentrations and light scattering coefficients in and around such slot are presented. An explanation is proposed for the propensity of CAS to form in southern Africa during the dry season.

  15. Three-Dimensional Array of TiN@Pt3Cu Nanowires as an Efficient Porous Electrode for the Lithium-Oxygen Battery.

    PubMed

    Luo, Wen-Bin; Pham, Thien Viet; Guo, Hai-Peng; Liu, Hua-Kun; Dou, Shi-Xue

    2017-02-28

    The nonaqueous lithium-oxygen battery is a promising candidate as a next-generation energy storage system because of its potentially high energy density (up to 2-3 kW kg -1 ), exceeding that of any other existing energy storage system for storing sustainable and clean energy to reduce greenhouse gas emissions and the consumption of nonrenewable fossil fuels. To achieve high round-trip efficiency and satisfactory cycling stability, the air electrode structure and the electrocatalysts play important roles. Here, a 3D array composed of one-dimensional TiN@Pt 3 Cu nanowires was synthesized and employed as a whole porous air electrode in a lithium-oxygen battery. The TiN nanowire was primarily used as an air electrode frame and catalyst support to provide a high electronic conductivity network because of the high-orientation one-dimensional crystalline structure. Meanwhile, deposited icosahedral Pt 3 Cu nanocrystals exhibit highly efficient catalytic activity owing to the abundant {111} active lattice facets and multiple twin boundaries. This porous air electrode comprises a one-dimensional TiN@Pt 3 Cu nanowire array that demonstrates excellent energy conversion efficiency and rate performance in full discharge and charge modes. The discharge capacity is up to 4600 mAh g -1 along with an 84% conversion efficiency at a current density of 0.2 mA cm -2 , and when the current density increased to 0.8 mA cm -2 , the discharge capacity is still greater than 3500 mAh g -1 together with a nearly 70% efficiency. This designed array is a promising bifunctional porous air electrode for lithium-oxygen batteries, forming a continuous conductive and high catalytic activity network to facilitate rapid gas and electrolyte diffusion and catalytic reaction throughout the whole energy conversion process.

  16. Tuberculosis Infection Control in Health-Care Facilities: Environmental Control and Personal Protection.

    PubMed

    Lee, Ji Yeon

    2016-10-01

    Transmission of tuberculosis (TB) is a recognized risk to patients and healthcare workers in healthcare settings. The literature review suggests that implementation of combination control measures reduces the risk of TB transmission. Guidelines suggest a three-level hierarchy of controls including administrative, environmental, and respiratory protection. Among environmental controls, installation of ventilation systems is a priority because ventilation reduces the number of infectious particles in the air. Natural ventilation is cost-effective but depends on climatic conditions. Supplemented intervention such as air-cleaning methods including high efficiency particulate air filtration and ultraviolet germicidal irradiation should be considered in areas where adequate ventilation is difficult to achieve. Personal protective equipment including particulate respirators provides additional benefit when administrative and environmental controls cannot assure protection.

  17. Clean Air. It's Up to You, Too.

    ERIC Educational Resources Information Center

    Environmental Protection Agency, Washington, DC.

    Opportunities for citizen participation in federal environmental decisions relative to air pollution and its control are assessed in this booklet. The Environmental Protection Agency (EPA), as the federal agency charged with enforcement of the Clean Air Act, offers guidelines for responsible citizen action. Designed for groups already organized…

  18. 40 CFR 91.603 - Applicability of part 91, subpart F.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... violations of the Clean Air Act and the regulations thereunder. (Authorized Company Representative.) (9.... 91.603 Section 91.603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... representative of the manufacturer: This report is submitted pursuant to Sections 213 and 208 of the Clean Air...

  19. 40 CFR 91.603 - Applicability of part 91, subpart F.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... violations of the Clean Air Act and the regulations thereunder. (Authorized Company Representative.) (9.... 91.603 Section 91.603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... representative of the manufacturer: This report is submitted pursuant to Sections 213 and 208 of the Clean Air...

  20. 40 CFR 91.603 - Applicability of part 91, subpart F.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... violations of the Clean Air Act and the regulations thereunder. (Authorized Company Representative.) (9.... 91.603 Section 91.603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR... representative of the manufacturer: This report is submitted pursuant to Sections 213 and 208 of the Clean Air...

  1. 40 CFR 91.603 - Applicability of part 91, subpart F.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... violations of the Clean Air Act and the regulations thereunder. (Authorized Company Representative.) (9....603 Section 91.603 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... representative of the manufacturer: This report is submitted pursuant to Sections 213 and 208 of the Clean Air...

  2. A centrifuge CO2 pellet cleaning system

    NASA Technical Reports Server (NTRS)

    Foster, C. A.; Fisher, P. W.; Nelson, W. D.; Schechter, D. E.

    1995-01-01

    An advanced turbine/CO2 pellet accelerator is being evaluated as a depaint technology at Oak Ridge National Laboratory (ORNL). The program, sponsored by Warner Robins Air Logistics Center (ALC), Robins Air Force Base, Georgia, has developed a robot-compatible apparatus that efficiently accelerates pellets of dry ice with a high-speed rotating wheel. In comparison to the more conventional compressed air 'sandblast' pellet accelerators, the turbine system can achieve higher pellet speeds, has precise speed control, and is more than ten times as efficient. A preliminary study of the apparatus as a depaint technology has been undertaken. Depaint rates of military epoxy/urethane paint systems on 2024 and 7075 aluminum panels as a function of pellet speed and throughput have been measured. In addition, methods of enhancing the strip rate by combining infra-red heat lamps with pellet blasting and by combining the use of environmentally benign solvents with the pellet blasting have also been studied. The design and operation of the apparatus will be discussed along with data obtained from the depaint studies.

  3. NASA Principal Center for Review of Clean Air Act Regulations

    NASA Technical Reports Server (NTRS)

    Clark-Ingram, Marceia; Munafo, Paul M. (Technical Monitor)

    2002-01-01

    The Clean Air Act (CAA) regulations have greatly impacted materials and processes utilized in the manufacture of aerospace hardware. Code JE/ NASA's Environmental Management Division at NASA Headquarters recognized the need for a formal, Agency-wide review process of CAA regulations. Marshall Space Flight Center (MSFC) was selected as the 'Principal Center for Review of Clean Air Act Regulations'. This presentation describes the centralized support provided by MSFC for the management and leadership of NASA's CAA regulation review process.

  4. Monitoring minimization of grade B environments based on risk assessment using three-dimensional airflow measurements and computer simulation.

    PubMed

    Katayama, Hirohito; Higo, Takashi; Tokunaga, Yuji; Katoh, Shigeo; Hiyama, Yukio; Morikawa, Kaoru

    2008-01-01

    A practical, risk-based monitoring approach using the combined data collected from actual experiments and computer simulations was developed for the qualification of an EU GMP Annex 1 Grade B, ISO Class 7 area. This approach can locate and minimize the representative number of sampling points used for microbial contamination risk assessment. We conducted a case study on an aseptic clean room, newly constructed and specifically designed for the use of a restricted access barrier system (RABS). Hotspots were located using three-dimensional airflow analysis based on a previously published empirical measurement method, the three-dimensional airflow analysis. Local mean age of air (LMAA) values were calculated based on computer simulations. Comparable results were found using actual measurements and simulations, demonstrating the potential usefulness of such tools in estimating contamination risks based on the airflow characteristics of a clean room. Intensive microbial monitoring and particle monitoring at the Grade B environmental qualification stage, as well as three-dimensional airflow analysis, were also conducted to reveal contamination hotspots. We found representative hotspots were located at perforated panels covering the air exhausts where the major piston airflows collect in the Grade B room, as well as at any locations within the room that were identified as having stagnant air. However, we also found that the floor surface air around the exit airway of the RABS EU GMP Annex 1 Grade A, ISO Class 5 area was always remarkably clean, possibly due to the immediate sweep of the piston airflow, which prevents dispersed human microbes from falling in a Stokes-type manner on settling plates placed on the floor around the Grade A exit airway. In addition, this airflow is expected to be clean with a significantly low LMAA. Based on these observed results, we propose a simplified daily monitoring program to monitor microbial contamination in Grade B environments. To locate hotspots we propose using a combination of computer simulation, actual airflow measurements, and intensive environmental monitoring at the qualification stage. Thereafter, instead of particle or microbial air monitoring, we recommend the use of microbial surface monitoring at the main air exhaust. These measures would be sufficient to assure the efficiency of the monitoring program, as well as to minimize the number of surface sampling points used in environments surrounding a RABS.

  5. 75 FR 22400 - Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Wheelabrator...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-04-28

    ... ENVIROMENTAL PROTECTION AGENCY [FRL-9142-6] Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Wheelabrator Baltimore, L.P., Baltimore City, MD AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of final action. SUMMARY: Pursuant to section 505(b)(2) of the Clean...

  6. Food-Growing, Air- And Water-Cleaning Module

    NASA Technical Reports Server (NTRS)

    Sauer, R. L.; Scheld, H. W.; Mafnuson, J. W.

    1988-01-01

    Apparatus produces fresh vegetables and removes pollutants from air. Hydroponic apparatus performs dual function of growing fresh vegetables and purifying air and water. Leafy vegetables rooted in granular growth medium grow in light of fluorescent lamps. Air flowing over leaves supplies carbon dioxide and receives fresh oxygen from them. Adaptable to production of food and cleaning of air and water in closed environments as in underwater research stations and submarines.

  7. Tooth Surface Comparison after Air Polishing and Rubber Cup: A Scanning Electron Microscopy Study.

    PubMed

    Camboni, Sara; Donnet, Marcel

    2016-03-01

    To demonstrate, using microscopic observations, the difference between two well-known oral prophylaxis techniques: polishing paste and air polishing. The observations were performed on human enamel. Enamel samples were obtained from plaque-rich human teeth extracted for orthodontic or clinical purposes. In order to allow a reliable comparison between different applications, each enamel sample was divided into two parts: one underwent air-polishing, whereas polishing paste was applied to the other. AIR-FLOW® Master was selected together with AIR-FLOW® PLUS for the prophylaxis powder application. For the polishing-paste application, several different pastes where used, including Cleanic®, CCS®, Proxyt®, and SuperPolish. A comparative test control was also used by cleaning the enamel with sodium hypochlorite (6%). The enamel treated with AIR-FLOW PLUS showed a similar surface when compared to the control enamel; however, there was complete cleaning down to the tooth microstructure. On the other hand, use of the polishing paste resulted in an enamel surface that appeared abraded and flattened. Moreover, some of the natural irregular enamel surfaces demonstrated some filling in with debris. AIR-FLOW PLUS powder was able to more deeply clean without creating any damage to the enamel, making it suitable for regular cleaning treatments. The polishing pastes were found to abrade the enamel surface, to flatten it, and deposit debris into the microcavities. Both methods having different mechanical effects can therefore be considered as complementary, in that some patients experience a sense of "roughness" following a cleaning. A clinical recommendation for this experience would be to use the air polish first to clean the enamel surface, and follow with a little polishing paste to smooth the surface, if required.

  8. Report: EPA Relying on Existing Clean Air Act Regulations to Reduce Atmospheric Deposition to the Chesapeake Bay and its Watershed

    EPA Pesticide Factsheets

    Report #2007-P-00009, February 28, 2007. EPA’s Chesapeake Bay Program Office is relying on anticipated nitrogen deposition reductions from Clean Air Act (CAA) regulations already issued by EPA, combined with other non-air sources' anticipated reductions.

  9. 76 FR 40728 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2011 Clean Air Excellence...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-11

    ... Childers, U.S. EPA at 202-564-1082 or 202- 564-1352 (Fax), mailing address: Office of Air and Radiation.../index.html or by contacting Mr. Pat Childers, U.S. EPA at 202-564-1082 or 202-564-1352 (Fax), mailing...

  10. 75 FR 35025 - Clean Air Act Advisory Committee (CAAAC); Request for Nominations for 2010 Clean Air Excellence...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-21

    ... 202-564-1082 or 202- 564-1352 (Fax), mailing address: Office of Air and Radiation (6102A), 1200.../caaac by clicking on Awards Program or by contacting Mr. Pat Childers, U.S. EPA at 202-564-1082 or 202...

  11. SENSITIVITY ANALYSIS OF THE MULTI-LAYER MODEL USED IN THE CLEAN AIR STATUS AND TRENDS NETWORK (CASTNET)

    EPA Science Inventory

    The U.S. Environmental Protection Agency (EPA) established the Clean Air Status and Trends Network (CASTNET) and its predecessor, the National Dry Deposition Network (NDDN), as national air quality and meteorological monitoring networks. The purpose of CASTNET is to track the pr...

  12. 76 FR 9609 - Notice of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-18

    ... the Environmental Protection Agency and the San Joaquin Valley Unified Air Pollution Control District... related to emissions of pollutants; install and operate required pollution control technology; undertake... DEPARTMENT OF JUSTICE Notice of Proposed Consent Decree Under the Clean Air Act Notice is hereby...

  13. 77 FR 54382 - Revisions of Five California Clean Air Act Title V Operating Permits Programs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-05

    ... Five California Clean Air Act Title V Operating Permits Programs AGENCY: Environmental Protection... Permits (Title V) programs of the Monterey Bay Unified Air Pollution Control District (MBUAPCD), San Luis... thresholds in EPA's Tailoring Rule, which have not been previously subject [[Page 54383

  14. 75 FR 9410 - Science Advisory Board Staff Office Notification of a Public Teleconference of the Air Quality...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-02

    ... advisory report on EPA's air quality modeling work for the Second Section 812 Prospective Benefit-Cost... Section 812 Benefit-Cost Analysis of the Clean Air Act. The Council was established in 1991 pursuant to... assess benefits and costs of the EPA's regulatory actions under the Clean Air Act. The Council has...

  15. RESULTS OF A PILOT FIELD STUDY TO EVALUATE THE EFFECTIVENESS OF CLEANING RESIDENTIAL HEATING AND AIR-CONDITIONING SYSTEMS AND THE IMPACT ON INDOOR AIR QUALITY AND SYSTEM PERFORMANCE

    EPA Science Inventory

    The report discusses and gives results of a pilot field study to evaluate the effectiveness of air duct cleaning (ADC) as a source removal technique in residential heating and air-conditioning (HAC) systems and its impact on airborne particle, fiber, and bioaerosol concentrations...

  16. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14815 What are the emission limitations for air curtain incinerators that burn 100...

  17. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Modification or Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only... requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Prior to...

  18. 40 CFR 60.2973 - What are the recordkeeping and reporting requirements for air curtain incinerators that burn only...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... reporting requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste... Modification or Reconstruction is Commenced on or After June 16, 2006 Air Curtain Incinerators That Burn Only... requirements for air curtain incinerators that burn only wood waste, clean lumber, and yard waste? (a) Prior to...

  19. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14815 What are the emission limitations for air curtain incinerators that burn 100...

  20. 40 CFR 62.14815 - What are the emission limitations for air curtain incinerators that burn 100 percent wood wastes...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... air curtain incinerators that burn 100 percent wood wastes, clean lumber and/or yard waste? 62.14815... Before November 30, 1999 Air Curtain Incinerators That Burn 100 Percent Wood Wastes, Clean Lumber And/or Yard Waste § 62.14815 What are the emission limitations for air curtain incinerators that burn 100...

  1. Core/Combustor Noise - Research Overview

    NASA Technical Reports Server (NTRS)

    Hultgren, Lennart S.

    2017-01-01

    Contributions from the combustor to the overall propulsion noise of civilian transport aircraft are starting to become important due to turbofan design trends and advances in mitigation of other noise sources. Future propulsion systems for ultra-efficient commercial air vehicles are projected to be of increasingly higher bypass ratio from larger fans combined with much smaller cores, with ultra-clean burning fuel-flexible combustors. Unless effective noise-reduction strategies are developed, combustor noise is likely to become a prominent contributor to overall airport community noise in the future. This presentation gives a brief overview of the NASA outlook on pertinent issues and far-term research needs as well as current and planned research in the core/combustor-noise area. The research described herein is aligned with the NASA Ultra-Efficient Commercial Transport strategic thrust and is supported by the NASA Advanced Air Vehicle Program, Advanced Air Transport Technology Project, under the Aircraft Noise Reduction Subproject. The overarching goal of the Advanced Air Transport Technology (AATT) Project is to explore and develop technologies and concepts to revolutionize the energy efficiency and environmental compatibility of fixed wing transport aircrafts. These technological solutions are critical in reducing the impact of aviation on the environment even as this industry and the corresponding global transportation system continue to grow.

  2. A mechanistic study of limonene oxidation products and pathways following cleaning activities

    NASA Astrophysics Data System (ADS)

    Carslaw, Nicola

    2013-12-01

    Indoor air pollution has caused increasing concern since the 1970s, when the advent of stricter energy efficiency measures lead to increased reports of building related symptoms. Cleaning activities have been linked to adverse health effects indoors, although it is unclear which of the components of cleaning products cause these reported health effects. This paper uses a detailed chemical model for indoor air chemistry, to identify the species formed at the highest concentrations following use of a limonene-based cleaning product. The explicit nature of the chemical mechanism also permits the key pathways to their formation to be identified. The results show that the key species in terms of gas-phase concentration are multi-functional carbonyl species including limonaldehyde, 4-acetyl-1-methyl-1-cyclohexene and other dicarbonyl species. The particle-phase was dominated by peroxide species. The predicted gas-phase concentrations for three limonene-oxidation products were compared to recently published human reference values, but found not to be high enough to cause concern for typical indoor conditions, or under high indoor ozone conditions. However, cleaning products contain a range of terpenes other than limonene, which could also produce some of the secondary products identified here, as well as more common species such as formaldehyde, glyoxal and hydrogen peroxide. A mechanistic pathway analysis shows that the secondary products formed through limonene oxidation indoors depend critically on the competition between ozone and hydroxyl radicals, such that indoor pollutant concentrations and composition could vary widely in different locations for a nominally similar residence and indoor activities. Future studies should focus on aiming to measure multi-functional carbonyl species indoors to help validate models, whilst human reference values are needed for many more relevant species indoors.

  3. Photochemical Modeling Applications

    EPA Pesticide Factsheets

    Provides access to modeling applications involving photochemical models, including modeling of ozone, particulate matter (PM), and mercury for national and regional EPA regulations such as the Clean Air Interstate Rule (CAIR) and the Clean Air Mercury Rule

  4. Alternative Fuels Data Center

    Science.gov Websites

    AirCheckTexas Drive a Clean Machine program, which provides vehicle replacement assistance for qualified requirements, and how to apply in specific areas, see the AirCheckTexas Drive a Clean Machine website

  5. Clean Air Markets - Part 75 Emissions Monitoring Policy Manual

    EPA Pesticide Factsheets

    Learn about monitoring mass sulfur dioxide and mass carbon dioxide emissions, nitrogen oxide emission rate, and heat input by units affected by the Acid Rain Program and the Clean Air Interstate Rule.

  6. A Multi-Year Study of Tobacco Control in Newspaper Editorials Using Community Characteristic Data and Content Analysis Findings.

    PubMed

    Stanfield, Kellie; Rodgers, Shelly

    2018-07-01

    We content analyzed 1,473 newspaper editorials for topic, tone, and slant, and connected the results to community characteristic data: clean indoor air ordinance status for cities, and official smoking rates for counties. The analysis occurred during a multi-year project aimed at prompting communities to adopt clean indoor air policies. The results showed that most editorials were about tobacco restrictions or ordinances, were neutral in tone, and provided factual information about tobacco control. More editorials were negatively slanted vs. positively slanted toward tobacco control. Most editorials with positive tones were published in newspapers in towns that already had clean indoor air policies. We concluded that editorials might hold increased weight in spurring change, as the percentage of smokers in a city is unrelated to the town enacting a clean indoor air ordinance.

  7. Near-infrared spectroscopy (NIRS) as a tool to monitor exhaust air from poultry operations.

    PubMed

    Druckenmüller, Katharina; Günther, Klaus; Elbers, Gereon

    2018-07-15

    Intensive poultry operation systems emit a considerable volume of inorganic and organic matter in the surrounding environment. Monitoring cleaning properties of exhaust air cleaning systems and to detect small but significant changes in emission characteristics during a fattening cycle is important for both emission and fattening process control. In the present study, we evaluated the potential of near-infrared spectroscopy (NIRS) combined with chemometric techniques as a monitoring tool of exhaust air from poultry operation systems. To generate a high-quality data set for evaluation, the exhaust air of two poultry houses was sampled by applying state-of-the-art filter sampling protocols. The two stables were identical except for one crucial difference, the presence or absence of an exhaust air cleaning system. In total, twenty-one exhaust air samples were collected at the two sites to monitor spectral differences caused by the cleaning device, and to follow changes in exhaust air characteristics during a fattening period. The total dust load was analyzed by gravimetric determination and included as a response variable in multivariate data analysis. The filter samples were directly measured with NIR spectroscopy. Principal component analysis (PCA), linear discriminant analysis (LDA), and factor analysis (FA) were effective in classifying the NIR exhaust air spectra according to fattening day and origin. The results indicate that the dust load and the composition of exhaust air (inorganic or organic matter) substantially influence the NIR spectral patterns. In conclusion, NIR spectroscopy as a tool is a promising and very rapid way to detect differences between exhaust air samples based on still not clearly defined circumstances triggered during a fattening period and the availability of an exhaust air cleaning system. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  8. Precision Cleaning of Oxygen Systems and Components

    NASA Technical Reports Server (NTRS)

    McLaughlin, Russell

    2009-01-01

    Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic hydrocarbon chains of lengths between fifteen and fifty. Contaminants were tested both individually and in combination. All combinations were done with equal weights of the constituent contaminants.

  9. Central venous catheter - dressing change

    MedlinePlus

    ... will need: Sterile gloves Cleaning solution A special sponge A special patch, called a Biopatch A clear ... around the catheter. Clean the skin with the sponge and cleaning solution. Air dry after cleaning. Place ...

  10. Evaluation of the ICET Test Stand to Assess the Performance of a Range of Ceramic Media Filter Elements in Support of ASME AG-1 Subsection FO

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schemmel, A.

    High Efficiency Particulate Air (HEPA) filters are defined as extended-medium, dry-type filters with: (1) a minimum particle removal efficiency of no less than 99.97 percent for 0.3 micrometer particles, (2) a maximum, clean resistance of 1.0 inch water column (in. WC) when operated at 1,000 cubic feet per minute (CFM), and (3) a rigid casing that extends the full depth of the medium. Specifically, ceramic media HEPA filters provide better performance at elevated temperatures, are moisture resistant and nonflammable, can perform their function if wetted and exposed to greater pressures, and can be cleaned and reused. This paper describes themore » modification and design of a large scale test stand which properly evaluates the filtration characteristics of a range of ceramic media filters challenged with a nuclear aerosol agent in order to develop Section FO of ASME AG-1.« less

  11. 40 CFR 60.2972 - How must I monitor opacity for air curtain incinerators that burn only wood waste, clean lumber...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... curtain incinerators that burn only wood waste, clean lumber, and yard waste? 60.2972 Section 60.2972... PERFORMANCE FOR NEW STATIONARY SOURCES Operator Training and Qualification Air Curtain Incinerators That Burn... incinerators that burn only wood waste, clean lumber, and yard waste? (a) Use Method 9 of appendix A of this...

  12. Relevance of the EU Structural Funds’ Allocation to the Needs of Combating Air Pollution in Poland. Analysis of the Operational Programmes of Regions Threatened With Critical Air Pollution from Distributed Energy Sources

    NASA Astrophysics Data System (ADS)

    Włodarski, Marcin; Martyniuk-Pęczek, Justyna

    2017-10-01

    Recent years, the European Environmental Agency, has been reporting air quality parameters in Poland, as the poorest among all the EU countries. Despite of adoption of the EU legislation on energy efficiency and energy performance of buildings, existing legal solutions occur insufficient in reducing air pollution in Polish regions. Lack of an effective schemes supporting complex thermal renovation of buildings, exchange of inefficient boilers, developing district heating based on clean and renewable fuels results in severe health problems and 40 000 of premature deaths related to air pollution. Availability of the EU structural funds may become a tremendous opportunity, especially for the residential sector, to conduct a massive scale modernization. Nevertheless, lack of a coordinated action involving all levels of governance may put the opportunity at risk. The article aims to answer the question on the readiness of the regional governments to effectively implement energy efficiency measures mitigating the problem of air pollution. Second objective is to analyse whether the Regional Operational Programmes allocating the ERDF funds to support specific development needs of the regions, have been constructed in a way that properly addresses the problems related to energy performance of residential buildings.

  13. Thermodynamic analysis of engineering solutions aimed at raising the efficiency of integrated gasification combined cycle

    NASA Astrophysics Data System (ADS)

    Gordeev, S. I.; Bogatova, T. F.; Ryzhkov, A. F.

    2017-11-01

    Raising the efficiency and environmental friendliness of electric power generation from coal is the aim of numerous research groups today. The traditional approach based on the steam power cycle has reached its efficiency limit, prompted by materials development and maneuverability performance. The rival approach based on the combined cycle is also drawing nearer to its efficiency limit. However, there is a reserve for efficiency increase of the integrated gasification combined cycle, which has the energy efficiency at the level of modern steam-turbine power units. The limit of increase in efficiency is the efficiency of NGCC. One of the main problems of the IGCC is higher costs of receiving and preparing fuel gas for GTU. It would be reasonable to decrease the necessary amount of fuel gas in the power unit to minimize the costs. The effect can be reached by raising of the heat value of fuel gas, its heat content and the heat content of cycle air. On the example of the process flowsheet of the IGCC with a power of 500 MW, running on Kuznetsk bituminous coal, by means of software Thermoflex, the influence of the developed technical solutions on the efficiency of the power plant is considered. It is received that rise in steam-air blast temperature to 900°C leads to an increase in conversion efficiency up to 84.2%. An increase in temperature levels of fuel gas clean-up to 900°C leads to an increase in the IGCC efficiency gross/net by 3.42%. Cycle air heating reduces the need for fuel gas by 40% and raises the IGCC efficiency gross/net by 0.85-1.22%. The offered solutions for IGCC allow to exceed net efficiency of analogous plants by 1.8-2.3%.

  14. Streamlining the SIP Process

    EPA Pesticide Factsheets

    EPA collaborated with the The National Association of Clean Air Agencies (NACAA/ECOs) SIP Reform Work Group to minimize federal and state burden in developing SIPs, but ensure the plans effectiveness in complying with the Clean Air Act.

  15. Proceedings of the fifteenth DOE nuclear air cleaning conference

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    First, M.W.

    1979-02-01

    Papers presented are grouped under the following topics: noble gas separation, damage control, aerosols, test methods, new air cleaning technology from Europe, open-end, and filtration. A separate abstract was prepared for each paper.

  16. Clean Air Markets - Monitoring Surface Water Chemistry

    EPA Pesticide Factsheets

    Learn about how EPA uses Long Term Monitoring (LTM) and Temporily Integrated Monitoring of Ecosystems (TIME) to track the effect of the Clean Air Act Amendments on acidity of surface waters in the eastern U.S.

  17. PRN 93-5: Labeling Requirements of the Clean Air Act

    EPA Pesticide Factsheets

    A regulation under the Clean Air Act requires a warning statement on products (including pesticide products) manufactured with or containing Class I ozone-depleting substances, including chlorofluorocarbons, methyl chloroform and carbon tetrachloride.

  18. MTU America Inc. Clean Air Act Settlement

    EPA Pesticide Factsheets

    The settlement resolves an enforcement action by EPA and the U.S. Department of Justice against MTU for Clean Air Act (CAA) violations involving MTU’s failure to comply with certain testing, certification and reporting.

  19. Final Report of the Advanced Coal Technology Work Group

    EPA Pesticide Factsheets

    The Advanced Coal Technology workgroup reported to the Clean Air Act Advisory Committee. This page includes the final report of the Advanced Coal Technology Work Group to the Clean Air Act Advisory Committee.

  20. 76 FR 21346 - Science Advisory Board Staff Office, Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-15

    ... a Public Teleconference of the Clean Air Scientific Advisory Committee (CASAC) Lead Review Panel... (CASAC) Lead Review Panel to provide consultative advice on EPA's draft Integrated Review Plan for the National Ambient Air Quality Standards for Lead (draft IRP). DATES: The public teleconference will be held...

  1. Impact of Clean Air Regulations on Nitrogen Fate and Transport in Neuse River Basin

    EPA Science Inventory

    We investigated impacts of Clean Air Act (CAA) nitrogen emissions regulations on the fate and transport of nitrogen for two watersheds in the Neuse River Basin. The Soil and Water Assessment Tool (SWAT) and the Community Multi-Scale Air Quality (CMAQ) models were used. Two scenar...

  2. 76 FR 10361 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... July 14, 2010 response of the CDPHE, Air Pollution Control Division to the October 8, 2009 Order by EPA... ENVIRONMENTAL PROTECTION AGENCY [FRL-9270-5] Clean Air Act Operating Permit Program; Petition for... issued by the Colorado Department of Public Health and Environment (CDPHE). Specifically, the...

  3. Smogbusters: Grassroots Action for Clean Air and Sustainable Transport in Australia

    ERIC Educational Resources Information Center

    Manners, Eric; Wake, David; Carlisle, Rachel

    2009-01-01

    Smogbusters was a national, community-based, government-funded community education program promoting clean air and sustainable transport in Australia from 1994 to 2002. Smogbusters aimed to improve air quality primarily by raising awareness about motor vehicle transport and its negative impacts on health, the environment and communities, and by…

  4. Clean Air Markets - Facility Attributes and Contacts Query Wizard

    EPA Pesticide Factsheets

    The Facility Attributes and Contacts Query Wizard is part of a suite of Clean Air Markets-related tools that are accessible at http://camddataandmaps.epa.gov/gdm/index.cfm. The Facility Attributes and Contact module gives the user access to current and historical facility, owner, and representative data using custom queries, via the Facility Attributes Query Wizard, or Quick Reports. In addition, data regarding EPA, State, and local agency staff are also available. The Query Wizard can be used to search for data about a facility or facilities by identifying characteristics such as associated programs, owners, representatives, locations, and unit characteristics, facility inventories, and classifications.EPA's Clean Air Markets Division (CAMD) includes several market-based regulatory programs designed to improve air quality and ecosystems. The most well-known of these programs are EPA's Acid Rain Program and the NOx Programs, which reduce emissions of sulfur dioxide (SO2) and nitrogen oxides (NOx)-compounds that adversely affect air quality, the environment, and public health. CAMD also plays an integral role in the development and implementation of the Clean Air Interstate Rule (CAIR).

  5. A first French assessment of population exposure to tetrachloroethylene from small dry-cleaning facilities.

    PubMed

    Chiappini, L; Delery, L; Leoz, E; Brouard, B; Fagault, Y

    2009-06-01

    Used as a solvent in the dry-cleaning industry, tetrachloroethylene (C(2)Cl(4)) can be a pollutant of residential indoor air, which can cause long-term harmful exposures because of its neurotoxicity and probable carcinogenicity. In France, dry-cleaning facilities are integrated in urban environments (shopping malls, residential buildings) and can contribute to C(2)Cl(4) exposure for customers and residents. This exploratory work presents the results from five studies carried out in one shopping mall and four residential buildings housing a dry-cleaning facility. These studies involved dry-cleaning machines fitted with a Carbon Adsorber and unfitted, with or without Air Exhaust System. Samples were collected in the cleaning facilities and in the apartments located above with passive samplers allowing measurement of time-integrated concentrations on a 7 days sampling period. It has obviously shown the degradation of indoor air quality in these environments and underlined the contributing role of the machine technology and ventilation system on the amount of released C(2)Cl(4) in the indoor air. To temper these results, it must be pointed out that some parameters (building insulation, amount of solvent used...) which would influence C(2)Cl(4) fugitive release have not been quantified and should be looked at in further studies. In France, dry-cleaning facilities are frequently integrated in urban environments (large shopping malls or residential buildings) and can significantly contribute to tetrachloroethylene (C(2)Cl(4)) population exposure. The amount of fugitive releases in these environments depends on several parameters such as the dry-cleaning machine technology (fitted or unfitted with a carbon adsorber) and the ventilation (air exhaust system). To reduce C(2)Cl(4) exposure in residential buildings and other indoor environments with on-site dry cleaners, carbon adsorber unequipped machine should be replaced by newer technology and dry cleaners should be equipped with mechanical air exhaust systems.

  6. Quantitative Guidance for Stove Usage and Performance to Achieve Health and Environmental Targets

    PubMed Central

    Chiang, Ranyee A.

    2015-01-01

    Background Displacing the use of polluting and inefficient cookstoves in developing countries is necessary to achieve the potential health and environmental benefits sought through clean cooking solutions. Yet little quantitative context has been provided on how much displacement of traditional technologies is needed to achieve targets for household air pollutant concentrations or fuel savings. Objectives This paper provides instructive guidance on the usage of cooking technologies required to achieve health and environmental improvements. Methods We evaluated different scenarios of displacement of traditional stoves with use of higher performing technologies. The air quality and fuel consumption impacts were estimated for these scenarios using a single-zone box model of indoor air quality and ratios of thermal efficiency. Results Stove performance and usage should be considered together, as lower performing stoves can result in similar or greater benefits than a higher performing stove if the lower performing stove has considerably higher displacement of the baseline stove. Based on the indoor air quality model, there are multiple performance–usage scenarios for achieving modest indoor air quality improvements. To meet World Health Organization guidance levels, however, three-stone fire and basic charcoal stove usage must be nearly eliminated to achieve the particulate matter target (< 1–3 hr/week), and substantially limited to meet the carbon monoxide guideline (< 7–9 hr/week). Conclusions Moderate health gains may be achieved with various performance–usage scenarios. The greatest benefits are estimated to be achieved by near-complete displacement of traditional stoves with clean technologies, emphasizing the need to shift in the long term to near exclusive use of clean fuels and stoves. The performance–usage scenarios are also provided as a tool to guide technology selection and prioritize behavior change opportunities to maximize impact. Citation Johnson MA, Chiang RA. 2015. Quantitative guidance for stove usage and performance to achieve health and environmental targets. Environ Health Perspect 123:820–826; http://dx.doi.org/10.1289/ehp.1408681 PMID:25816219

  7. Parametric Evaluation of an Innovative Ultra-Violet PhotocatalyticOxidation (UVPCO) Air Cleaning Technology for Indoor Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hodgson, Alfred T.; Sullivan, Douglas P.; Fisk, William J.

    2005-10-31

    An innovative Ultra-Violet Photocatalytic Oxidation (UVPCO) air cleaning technology employing a semitransparent catalyst coated on a semitransparent polymer substrate was evaluated to determine its effectiveness for treating mixtures of volatile organic compounds (VOCs) representative of indoor environments at low, indoor-relevant concentration levels. The experimental UVPCO contained four 30 by 30-cm honeycomb monoliths irradiated with nine UVA lamps arranged in three banks. A parametric evaluation of the effects of monolith thickness, air flow rate through the device, UV power, and reactant concentrations in inlet air was conducted for the purpose of suggesting design improvements. The UVPCO was challenged with three mixturesmore » of VOCs. A synthetic office mixture contained 27 VOCs commonly measured in office buildings. A building product mixture was created by combining sources including painted wallboard, composite wood products, carpet systems, and vinyl flooring. The third mixture contained formaldehyde and acetaldehyde. Steady state concentrations were produced in a classroom laboratory or a 20-m{sup 3} chamber. Air was drawn through the UVPCO, and single-pass conversion efficiencies were measured from replicate samples collected upstream and downstream of the reactor. Thirteen experiments were conducted in total. In this UVPCO employing a semitransparent monolith design, an increase in monolith thickness is expected to result in general increases in both reaction efficiencies and absolute reaction rates for VOCs oxidized by photocatalysis. The thickness of individual monolith panels was varied between 1.2 and 5 cm (5 to 20 cm total thickness) in experiments with the office mixture. VOC reaction efficiencies and rates increased with monolith thickness. However, the analysis of the relationship was confounded by high reaction efficiencies in all configurations for a number of compounds. These reaction efficiencies approached or exceeded 90% for alcohols, glycol ethers, and other individual compounds including d-limonene, 1,2,4-trimethylbenzene, and decamethylcyclopentasiloxane. This result implies a reaction efficiency of about 30% per irradiated monolith face, which is in agreement with the maximum efficiency for the system predicted with a simulation model. In these and other experiments, the performance of the system for highly reactive VOCs appeared to be limited by mass transport of reactants to the catalyst surface rather than by photocatalytic activity. Increasing the air flow rate through the UVPCO device decreases the residence time of the air in the monoliths and improves mass transfer to the catalyst surface. The effect of gas velocity was examined in four pairs of experiments in which the air flow rate was varied from approximately 175 m{sup 3}/h to either 300 or 600 m{sup 3}/h. Increased gas velocity caused a decrease in reaction efficiency for nearly all reactive VOCs. For all of the more reactive VOCs, the decrease in performance was less, and often substantially less, than predicted based solely on residence time, again likely due to mass transfer limitations at the low flow rate. The results demonstrate that the UVPCO is capable of achieving high conversion efficiencies for reactive VOCs at air flow rates above the base experimental rate of 175 m{sup 3}/h. The effect of UV power was examined in a series of experiments with the building product mixture in which the number of lamps was varied between nine and three. For the most reactive VOCs in the mixture, the effects of UV power were surprisingly small. Thus, even with only one lamp in each section, there appears to be sufficient photocatalytic activity to decompose most of the mass of reactive VOCs that reach the catalyst surface. For some less reactive VOCs, the trend of decreasing efficiency with decreasing UV intensity was in general agreement with simulation model predictions.« less

  8. A Pilot Study of the Effectiveness of Indoor Plants for Removal of Volatile Organic Compounds in Indoor Air in a Seven-Story Office Building

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Apte, Michael G.; Apte, Joshua S.

    2010-04-27

    The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rankmore » among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in the building. The plants used in the rooftop greenhouse and on the floors were made up of a number of species selected for the following functions: daytime metabolic carbon dioxide (CO{sub 2}) absorption, nighttime metabolic CO{sub 2} absorption, and volatile organic compound (VOC) and inorganic gas absorption/removal for air cleaning. The building contains a reported 910 indoor plants. Daytime metabolic species reported by the PBC include Areca Palm, Oxycardium, Rubber Plant, and Ficus alii totaling 188 plants (21%). The single nighttime metabolic species is the Sansevieria with a total of 28 plants (3%). The 'air cleaning' plant species reported by the PBC include the Money Plant, Aglaonema, Dracaena Warneckii, Bamboo Palm, and Raphis Palm with a total of 694 plants (76%). The plants in the greenhouse (Areca Palm, Rubber Plant, Ficus alii, Bamboo Palm, and Raphis Palm) numbering 161 (18%) of those in the building are grown hydroponically, with the room air blown by fan across the plant root zones. The plants on the building floors are grown in pots and are located on floors 1-6. We conducted a one-day monitoring session in the PBC on January 1, 2010. The date of the study was based on availability of the measurement equipment that the researchers had shipped from Lawrence Berkeley National Lab in the U.S.A. The study date was not optimal because a large proportion of the regular building occupants were not present being New Year's Day. An estimated 40 people were present in the building all day during January 1. This being said, the building systems were in normal operations, including the air handlers and other HVAC components. The study was focused primarily on measurements in the Greenhouse and 3rd and 5th floor environments as well as rooftop outdoors. Measurements included a set of volatile organic compounds (VOCs) and aldehydes, with a more limited set of observations of indoor and outdoor particulate and carbon dioxide concentrations. Continuous measurements of Temperature (T) and relative humidity (RH) were made selected indoor and outdoor locations.« less

  9. Properties and Fluxes of Primary Marine Aerosol Generated Via Detrainment of Turbulence-Modulated Bubble Plumes from Fresh North Atlantic Seawater

    NASA Astrophysics Data System (ADS)

    Keene, W. C.; Long, M. S.; Duplessis, P.; Kieber, D. J.; Maben, J. R.; Frossard, A. A.; Kinsey, J. D.; Beaupre, S. R.; Lu, X.; Chang, R.; Zhu, Y.; Bisgrove, J.

    2017-12-01

    During a September-October 2016 cruise of the R/V Endeavor in the western North Atlantic Ocean, primary marine aerosol (PMA) was produced in a high capacity generator during day and night via detrainment of bubbles from biologically productive and oligotrophic seawater. The turbulent mixing of clean air and seawater in a Venturi nozzle produced bubble plumes with tunable size distributions. Physicochemical characteristics of size-resolved PMA and seawater were measured. PMA number production efficiencies per unit air detrained (PEnum) increased with increasing detainment rate. For given conditions, PEnum values summed over size distributions were roughly ten times greater than those for frits whereas normalized size distributions were similar. Results show that bubble size distributions significantly modulated number production fluxes but not relative shapes of corresponding size distributions. In contrast, mass production efficiencies (PEmass) decreased with increasing air detrainment and were similar to those for frits, consistent with the hypothesis that bubble rafts on the seawater surface modulate emissions of larger jet droplets that dominate PMA mass production. Production efficiencies of organic matter were about three times greater than those for frits whereas organic enrichment factors integrated over size distributions were similar.

  10. Influences of Scavenging and Removal of Surfactants by Bubble Processing on Primary Marine Aerosol Production from North Atlantic Seawater

    NASA Astrophysics Data System (ADS)

    Duplessis, P.; Chang, R.; Frossard, A. A.; Keene, W. C.; Maben, J. R.; Long, M. S.; Beaupre, S. R.; Kieber, D. J.; Kinsey, J. D.; Zhu, Y.; Lu, X.; Bisgrove, J.

    2017-12-01

    Primary marine aerosol particles (PMA) are produced by bursting bubbles from breaking waves at the air-sea interface and significantly modulate atmospheric chemical transformations and cloud properties. Surfactants in bulk seawater rapidly (seconds) adsorb onto fresh bubble surfaces forming organic films that influence size, rise velocity, bursting behavior, and associated PMA emissions. During a cruise on the R/V Endeavor in September and October 2016, PMA production from biologically productive and oligotrophic seawater was investigated at four stations in the western North Atlantic Ocean. PMA were produced in a high-capacity generator via turbulent mixing of seawater and clean air in a Venturi nozzle. When the flow of fresh seawater through the generator was turned off, surfactant depletion via bubble processing resulted in greater PMA mass production efficiencies per unit air detrained but had no consistent influence on number production efficiencies. The greater (factor of 3) production efficiencies of organic matter associated with PMA generated with the Venturi relative to those generated with frits during previous campaigns contributed to a faster depletion of surfactants from the seawater reservoir and corresponding divergence in response.

  11. Investigation of aluminum surface cleaning using cavitating fluid flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ralys, Aurimas; Striška, Vytautas; Mokšin, Vadim

    This paper investigates efficiency of specially designed atomizer used to spray water and cavitate microbubbles in water flow. Surface cleaning system was used to clean machined (grinded) aluminum surface from abrasive particles. It is established that cleaning efficiency depends on diameter of the diffuser, water pressure and distance between nozzle and metal surface. It is obtained that the best cleaning efficiency (100%) is achieved at pressure 36 bar, when diameter of diffuser is 0.4 mm and distance between nozzle and surface is 1 mm. It is also established that satisfactory cleaning efficiency (80%) is achieved not only when atomizer ismore » placed closer to metal surface, but also at larger (120 mm) distances.« less

  12. Interactions between energy efficiency and emission trading under the 1990 Clean Air Act Amendments

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hillsman, E.L.; Alvic, D.R.

    1994-08-01

    The 1990 Clean Air Act Amendments affect electric utilities in numerous ways. The feature that probably has received the greatest attention is the provision to let utilities trade emissions of sulfur dioxide (SO{sub 2}), while at the same time requiring them to reduce S0{sub 2} emissions in 2000 by an aggregate 43%. The emission trading system was welcomed by many as a way of reducing the cost of reducing emissions, by providing greater flexibility than past approaches. This report examines some of the potential interactions between trading emissions and increasing end-use energy efficiency. The analysis focuses on emission trading inmore » the second phase of the trading program, which begins in 2000. The aggregate effects, calculated by an emission compliance and trading model, turn out to be rather small. Aggressive improvement of end-use efficiency by all utilities might reduce allowance prices by $22/ton (1990 dollars), which is small compared to the reduction that has occurred in the estimates of future allowance prices and when compared to the roughly $400/ton price we estimate as a base case. However, the changes in the allowance market that result are large enough to affect some compliance decisions. If utilities in only a few states improve end-use efficiency aggressively, their actions may not have a large effect on the price of an allowance, but they could alter the demand for allowances and thereby the compliance decisions of utilities in other states. The analysis shows how improving electricity end-use efficiency in some states can cause smaller emission reductions in other states, relative to what would have happened without the improvements. Such a result, while not surprising given the theory behind the emission trading system, is upsetting to people who view emissions, environmental protection, and energy efficiency in moral rather than strictly economic terms.« less

  13. PRN 93-4: Ban on Aerosol Products Containing CFCs and HCFCs under the Clean Air Act

    EPA Pesticide Factsheets

    This notice alerts pesticide registrants to a rule under the Clean Air Act banning distribution and sale of aerosol and pressurized products, including pesticide products, that contain chlorofluorocarbons (CFCs).

  14. Achieving Clean Air and Clean Water: The Report of the Blue Ribbon Panel on Oxygenates in Gasoline

    EPA Pesticide Factsheets

    The Blue Ribbon Panel's report consists of five issue summaries: water contamination; air quality benefits; prevention; treatment and remediation; fuel supply and cost; and comparing the fuel additives.

  15. Guidance on Streamlining the SIP Process

    EPA Pesticide Factsheets

    EPA collaborated with the The National Association of Clean Air Agencies (NACAA/ECOs) SIP Reform Work Group to minimize federal and state burden in developing SIPs, but ensure the plans effectiveness in complying with the Clean Air Act.

  16. Clean Air Act Section 112(r) Inspection Guidance Distribution Memorandum

    EPA Pesticide Factsheets

    This memorandum issues and makes immediately effective the document, Guidance for Conducting Risk Management Program Inspections under Clean Air Act Section 112(r), which supersedes the 1999 document on auditing risk management plans/programs.

  17. Performance Evaluation of Axial Flow AG-1 FC and Prototype FM (High Strength) HEPA Filters - 13123

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Giffin, Paxton K.; Parsons, Michael S.; Wilson, John A.

    High efficiency particulate air (HEPA) filters are routinely used in DOE nuclear containment activities. The Nuclear Air Cleaning Handbook (NACH) stipulates that air cleaning devices and equipment used in DOE nuclear applications must meet the American Society of Mechanical Engineers (ASME) Code on Nuclear Air and Gas Treatment (AG-1) standard. This testing activity evaluates two different axial flow HEPA filters, those from AG-1 Sections FC and FM. Section FM is under development and has not yet been added to AG-1 due to a lack of qualification data available for these filters. Section FC filters are axial flow units that utilizemore » a fibrous glass filtering medium. The section FM filters utilize a similar fibrous glass medium, but also have scrim backing. The scrim-backed filters have demonstrated the ability to endure pressure impulses capable of completely destroying FC filters. The testing activities presented herein will examine the total lifetime loading for both FC and FM filters under ambient conditions and at elevated conditions of temperature and relative humidity. Results will include loading curves, penetration curves, and testing condition parameters. These testing activities have been developed through collaborations with representatives from the National Nuclear Security Administration (NNSA), DOE Office of Environmental Management (DOE-EM), New Mexico State University, and Mississippi State University. (authors)« less

  18. 78 FR 52972 - Re-Publication of Notice of Lodging of Proposed Third Amendment to Consent Decree Under the Clean...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-27

    ... Decree Under the Clean Air Act On July 23, 2013, the Department of Justice lodged a proposed Third... Consent Decree resolving certain violations of the federal Clean Air Act, 42 U.S.C. 7401 et seq. by... Companies'') alleged by Plaintiff United States and Plaintiff-Intervenors the State of Alabama, the State of...

  19. The public health relevance of air pollution abatement.

    PubMed

    Künzli, N

    2002-07-01

    Assuming a causal relationship between current levels of air pollution and morbidity/mortality, it is crucial to estimate the public health relevance of the problem. The derivation of air pollution attributable cases faces inherent uncertainties and requires influential assumptions. Based on the results of the trinational impact assessment study of Austria, France, and Switzerland, where prudent estimates of the air pollution attributable cases (mortality, chronic bronchitis incidence, hospital admissions, acute bronchitis among children, restricted activity days, asthma attacks) have been made, influential uncertainties are quantified in this review. The public health impact of smoking, environmental tobacco smoke, and air pollution on the prevalence of chronic cough/phlegm are outlined. Despite all methodological caveats, impact assessment studies clearly suggest that public health largely benefits from better air quality. The studies are selective underestimates as they are strongly driven by mortality, but do not include full quantification of the impact on morbidity and their consequences on quality of life among the diseased and the caregivers. Air pollution abatement strategies are usually political in nature, targeting at polities, regulation and technology in mobile or stationary sources rather than at individuals. It is of note that key clean air strategies converge into abatement of climate change. In general, energy consumption is very closely related to both air pollution and greenhouse gases. The dominant causes of both problems are the excessive and inefficient combustion of fossil fuel. Thus, for many policy options, the benefit of air pollution abatement will go far beyond what prudent health-impact assessments may derive. From a climate change and air pollution perspective, improved energy efficiency and a strong and decisive departure from the "fossil fuel" combustion society is a science-based must. Health professionals must raise their voices in the political decision process to give strong support for clean air policies, both on a national and international level.

  20. Concentrations of selected contaminants in cabin air of airbus aircrafts.

    PubMed

    Dechow, M; Sohn, H; Steinhanses, J

    1997-07-01

    The concentrations of selected air quality parameters in aircraft cabins were investigated including particle numbers in cabin air compared to fresh air and recirculation air, the microbiological contamination and the concentration of volatile organic compounds (VOC). The Airbus types A310 of Swissair and A340 of Lufthansa were used for measurements. The particles were found to be mainly emitted by the passengers, especially by smokers. Depending on recirculation filter efficiency the recirculation air contained a lower or equal amount of particles compared to the fresh air, whereas the amount of bacteria exceeded reported concentrations within other indoor spaces. The detected species were mainly non-pathogenic, with droplet infection over short distances identified as the only health risk. The concentration of volatile organic compounds (VOC) were well below threshold values. Ethanol was identified as the compound with the highest amount in cabin air. Further organics were emitted by the passengers--as metabolic products or by smoking--and on ground as engine exhaust (bad airport air quality). Cleaning agents may be the source of further compounds.

  1. Relating health and climate impacts to grid-scale emissions using adjoint sensitivity modeling for the Climate and Clean Air Coalition

    NASA Astrophysics Data System (ADS)

    Henze, D. K.; Lacey, F.; Seltzer, M.; Vallack, H.; Kuylenstierna, J.; Bowman, K. W.; Anenberg, S.; Sasser, E.; Lee, C. J.; Martin, R.

    2013-12-01

    The Climate and Clean Air Coalition (CCAC) was initiated in 2012 to develop, understand and promote measures to reduce short lived climate forcers such as aerosol, ozone and methane. The Coalition now includes over 30 nations, and as a service to these nations is committed to providing a decision support toolkit that allows member nations to explore the benefits of a range of emissions mitigation measures in terms of the combined impacts on air quality and climate and so help in the development of their National Action Plans. Here we will present recent modeling work to support the development of the CCAC National Action Plans toolkit. Adjoint sensitivity analysis is presented as a means of efficiently relating air quality, climate and crop impacts back to changes in emissions from each species, sector and location at the grid-scale resolution of typical global air quality model applications. The GEOS-Chem adjoint model is used to estimate the damages per ton of emissions of PM2.5 related mortality, the impacts of ozone precursors on crops and ozone-related health effects, and the combined impacts of these species on regional surface temperature changes. We show how the benefits-per-emission vary spatially as a function of the surrounding environment, and how this impacts the overall benefit of sector-specific control strategies. We present initial findings for Bangladesh, as well as Mexico, Ghana and Colombia, some of the first countries to join the CCAC, and discuss general issues related to adjoint-based metrics for quantifying air quality and climate co-benefits.

  2. Children's exposure to indoor air in urban nurseries--Part II: Gaseous pollutants' assessment.

    PubMed

    Branco, P T B S; Nunes, R A O; Alvim-Ferraz, M C M; Martins, F G; Sousa, S I V

    2015-10-01

    This study, Part II of the larger study "Children's exposure to indoor air in urban nurseries", aimed to: (i) evaluate nursery schools' indoor concentrations of several air pollutants in class and lunch rooms; and (ii) analyse them according to guidelines and references. Indoor continuous measurements were performed, and outdoor concentrations were obtained to determine indoor/outdoor ratios. The influence of outdoor air seemed to be determinant on carbon monoxide (CO), nitrogen dioxide (NO2) and ozone (O3) indoor concentrations. The peak concentrations of formaldehyde and volatile organic compounds (VOC) registered (highest concentrations of 204 and 2320 µg m(-3) respectively), indicated the presence of specific indoor sources of these pollutants, namely materials emitting formaldehyde and products emitting VOC associated to cleaning and children's specific activities (like paints and glues). For formaldehyde, baseline constant concentrations along the day were also found in some of the studied rooms, which enhances the importance of detailing the study of children's short and long-term exposure to this indoor air pollutant. While CO, NO2 and O3 never exceeded the national and international reference values for IAQ and health protection, exceedances were found for formaldehyde and VOC. For this reason, a health risk assessment approach could be interesting for future research to assess children's health risks of exposure to formaldehyde and to VOC concentrations in nursery schools. Changing cleaning schedules and materials emitting formaldehyde, and more efficient ventilation while using products emitting VOC, with the correct amount and distribution of fresh air, would decrease children's exposure. Copyright © 2015 Elsevier Inc. All rights reserved.

  3. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  4. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  5. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  6. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  7. 40 CFR 60.3065 - What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... close my air curtain incinerator that burns only wood waste, clean lumber, and yard waste and not..., 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard Waste § 60.3065 What must I do if I plan to permanently close my air curtain incinerator that burns only wood...

  8. Peribronchiolar fibrosis in lungs of cats chronically exposed to diesel exhaust

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hyde, D.M.; Plopper, C.G.; Weir, A.J.

    This study reports the quantitative changes in the pulmonary proximal acinar region following chronic exposure to diesel exhaust and following an additional 6 months in clean air. Cats (13 months of age) from a minimum disease colony were exposed to clean air (eight cats for 27 months and nine cats for 33 months), diesel exhaust for 8 hours/day, 7 days/week (nine cats for 27 months), or diesel exhaust for 27 months followed by 6 months in clean air (10 cats). Morphologic and morphometric evaluation using light microscopy and scanning and transmission electron microscopy revealed two major exposure-related lesions in proximalmore » acinar regions of lungs of cats: peribronchiolar fibrosis associated with significant increases in lymphocytes, fibroblasts, and interstitial macrophages containing diesel particulate-like inclusions and bronchiolar epithelial metaplasia associated with the presence of ciliated and basal cells and alveolar macrophages containing diesel particulate-like inclusions. Peribronchiolar fibrosis was greater at the end of the 6 months in clean air following exposure, whereas the bronchiolar epithelial metaplasia was most severe at the end of exposure. Following an additional 6 months in clean air the epithelium more closely resembled the control epithelial cell population. The labeling index of terminal bronchiolar epithelium was significantly increased at the end of exposure but was not significantly different from controls or exposed cats following an additional 6 months in clean air. The ultrastructural appearance of epithelial cells remained relatively unchanged following diesel exhaust exposure with the exception of diesel particulate-like inclusions.« less

  9. 75 FR 8338 - EPA Science Advisory Board Staff Office Notification of a Meeting of the Ecological Effects...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-24

    ... the Second Section 812 Benefit-Cost Analysis of the Clean Air Act. The assessment of ecological... Analysis of the benefits and costs of the Clean Air Act. DATES: The EES augmented with additional experts... ecological effects of modeled air quality scenarios developed to support the Second Section 812 Benefit-Cost...

  10. 77 FR 39262 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-02

    ... Frozen Bakery Products, Inc. (collectively ``Cottage'') for violations of the federal Clean Air Act, 42 U... Joaquin Valley Unified Air Pollution Control District v. Cottage Bakery, Inc. and Ralcorp Frozen Bakery Products, Inc., case number 2:12-at-00895, was lodged with the United States District Court for the Eastern...

  11. 75 FR 30859 - Notice of Lodging of Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-02

    ... DEPARTMENT OF JUSTICE Notice of Lodging of Consent Decree Under the Clean Air Act Notice is hereby given that on May 24, 2010, a proposed Consent Decree in United States, and South Coast Air Quality Management District v. Lifoam Industries, LLC, Civil Action No. 10-CV-03825-AHM- FFM was lodged with the...

  12. 78 FR 68367 - Approval and Promulgation of Air Quality Implementation Plans; Ohio; Ohio NOX

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-14

    ... Clean Air Act, which allows for Ohio's Clean Air Interstate Rule (CAIR) NO X Ozone Season Trading Program rules to supersede Ohio's nitrogen oxides (NO X ) State Implementation Plan (SIP) Call Budget Trading Program rules, but leave other requirements of the NO X SIP Call in place for units not covered by...

  13. 77 FR 16509 - Proposed Approval of Revision of Five California Clean Air Act Title V Operating Permits Programs

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-21

    ... Approval of Revision of Five California Clean Air Act Title V Operating Permits Programs AGENCY... the Operating Permits (Title V) programs of the Monterey Bay Unified Air Pollution Control District... been previously subject to Title V for other reasons to obtain a Title V permit. See ``Prevention of...

  14. Synthetic Zeolites and Other Microporous Oxide Molecular Sieves

    NASA Astrophysics Data System (ADS)

    Sherman, John D.

    1999-03-01

    Use of synthetic zeolites and other microporous oxides since 1950 has improved insulated windows, automobile air-conditioning, refrigerators, air brakes on trucks, laundry detergents, etc. Their large internal pore volumes, molecular-size pores, regularity of crystal structures, and the diverse framework chemical compositions allow "tailoring" of structure and properties. Thus, highly active and selective catalysts as well as adsorbents and ion exchangers with high capacities and selectivities were developed. In the petroleum refining and petrochemical industries, zeolites have made possible cheaper and lead-free gasoline, higher performance and lower-cost synthetic fibers and plastics, and many improvements in process efficiency and quality and in performance. Zeolites also help protect the environment by improving energy efficiency, reducing automobile exhaust and other emissions, cleaning up hazardous wastes (including the Three Mile Island nuclear power plant and other radioactive wastes), and, as specially tailored desiccants, facilitating the substitution of new refrigerants for the ozone-depleting chlorofluorocarbons banned by the Montreal Protocol.

  15. ORD Clean Air Research Program Review and Response

    EPA Pesticide Factsheets

    The objective of this review was to evaluate the relevance, quality, performance, scientific and managerial leadership, and outcomes of the Program and provide guidance and recommendations as to the progress and directions of the Clean Air Research Program

  16. Notification: Evaluation of Enforcement Decree Compliance for Selected Clean Air Act Sources

    EPA Pesticide Factsheets

    Project #OPE-FY14-0016, May 22, 2014. The Office of Inspector General (OIG) plans to begin the preliminary research phase of an evaluation of enforcement decree compliance for selected Clean Air Act (CAA) sources.

  17. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... effect through the year 2020, as required by the Clean Air Act. If the area records a violation of the... that the maintenance plan will remain in effect through the year 2020, as required by the Clean Air Act...

  18. 40 CFR 52.1528 - Control strategy: Carbon monoxide.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... effect through the year 2020, as required by the Clean Air Act. If the area records a violation of the... that the maintenance plan will remain in effect through the year 2020, as required by the Clean Air Act...

  19. CARBON ADSORPTION FOR INDOOR AIR CLEANING

    EPA Science Inventory

    The paper discusses the use of carbon adsorption for indoor air cleaning, focusing on the removal of volatile organic compounds (VOCs) using granular activated carbon (GAC). It addresses GAC performance in two directions. Initially, it presents performance measurements for GAC at...

  20. PERFORMANCE TESTING OF AIR CLEANING PRODUCTS

    EPA Science Inventory

    The paper discuses the application of the Environmental Technology Verification (ETV) Program for products that clean ventilation air to the problem of protecting buildings from chemical and biological attack. This program is funded by the U.S. Environmental Protection Agency und...

  1. National Emission Standards for Hazardous Air Pollutants (NESHAP) Memorandum of Agreement (MOA) Between NASA Headquarters and MSFC (Marshall Space Flight Center) for NASA Principal Center for Review of Clean Air Regulations

    NASA Technical Reports Server (NTRS)

    Caruso, Salvadore V.; Clark-Ingram, Marceia A.

    2000-01-01

    This paper presents a memorandum of agreement on Clean Air Regulations. NASA headquarters (code JE and code M) has asked MSFC to serve as principle center for review of Clean Air Act (CAA) regulations. The purpose of the principle center is to provide centralized support to NASA headquarters for the management and leadership of NASA's CAA regulation review process and to identify the potential impact of proposed CAA reguations on NASA program hardware and supporting facilities. The materials and processes utilized in the manufacture of NASA's programmatic hardware contain HAPs (Hazardous Air Pollutants), VOCs (Volatile Organic Compounds), and ODC (Ozone Depleting Chemicals). This paper is presented in viewgraph form.

  2. Elimination of Acid Cleaning of High Temperature Salt Water Heat Exchangers: Redesigned Pre-Production Full-Scale Heat Pipe Bleed Air Cooler for Shipboard Evaluation

    DTIC Science & Technology

    2011-11-01

    Cleaning of High Temperature Salt Water Heat Exchangers ESTCP WP-200302 Subtitle: Redesigned Pre-production Full-Scale Heat Pipe Bleed Air Cooler For...FINAL 3. DATES COVERED (From - To) 1-Jan-2003 – 1-Oct-2009 4. TITLE AND SUBTITLE Elimination of Acid Cleaning of High Temperature Salt Water Heat...6-5 Figure 6- 6 HP-BAC Tube Sheet Being Immersed in Ultrasonic Cleaning Tank ..................................... 6-6 Figure 6- 7 Heat Pipe

  3. Analysis of S.1844, the Clear Skies Act of 2003; S. 843, the Clean Air Planning Act of 2003; and S. 366, the Clean Power Act of 2003

    EIA Publications

    2004-01-01

    Senator James M. Inhofe requested that the Energy Information Administration (EIA) undertake analysis of S.843, the Clean Air Planning Act of 2003, introduced by Senator Thomas Carper; S.366, the Clean Power Act of 2003, introduced by Senator James Jeffords; and S.1844, the Clear Skies Act of 2003, introduced by Senator James M. Inhofe. The EIA received this request on March 19, 2004. This Service Report responds to his request.

  4. Receiving and use of streams of monodisperse ice granules for cleaning and deactivation of surfaces

    NASA Astrophysics Data System (ADS)

    Boukharov, A.; Balashov, A.; Timohin, A.; Ivanov, A.; Holin, B.

    2017-11-01

    The most generally useful methods for cleaning and processing of surfaces are the sand-jets and shot blasting jets. Installations of this kind are used for cleaning of corrosion surfaces, the oil-dirt deposits, paint coatings. However the use of these installations follows to high investment and operational expenditure, larger risk of operators disease, the negative affect for a environment. These problems can be solved with the use of new cleaning method through application of mono-disperse (identical by the size and the form) ice granules of 300 - 1000 microns, accelerated by air stream in the nozzle device to the speed of 10 - 100 m/s. In view of the extreme complexity of the receiving such particles by means of cooling and the subsequent freezing of water drops are necessary additional experimental researches. For study of thermal processes of receiving mono-disperse ice granules the experimental installation was created and experiments on deactivation and cleaning of surfaces with pollution of various types are made. Experiments showed that by means of a stream of the accelerated ice granules it is rather successfully possible to delete oil-dirt deposits, outdated paint coats and rust. Besides, efficient deactivation of radioactive surfaces is possible. The coefficient deactivation of γ activity is highest.

  5. Ambient Air Quality Data Inventory

    EPA Pesticide Factsheets

    The Office of Air and Radiation's (OAR) Ambient Air Quality Data (Current) contains ambient air pollution data collected by EPA, other federal agencies, as well as state, local, and tribal air pollution control agencies. Its component data sets have been collected over the years from approximately 10,000 monitoring sites, of which approximately 5,000 are currently active. OAR's Office of Air Quality Planning and Standards (OAQPS) and other internal and external users, rely on this data to assess air quality, assist in Attainment/Non-Attainment designations, evaluate State Implementation Plans for Non-Attainment Areas, perform modeling for permit review analysis, and other air quality management functions. Air quality information is also used to prepare reports for Congress as mandated by the Clean Air Act. This data covers air quality data collected after 1980, when the Clean Air Act requirements for monitoring were significantly modified. Air quality data from the Agency's early years (1970s) remains available (see OAR PRIMARY DATA ASSET: Ambient Air Quality Data -- Historical), but because of technical and definitional differences the two data assets are not directly comparable. The Clean Air Act of 1970 provided initial authority for monitoring air quality for Conventional Air Pollutants (CAPs) for which EPA has promulgated National Ambient Air Quality Standards (NAAQS). Requirements for monitoring visibility-related parameters were added in 1977. Requiremen

  6. The Catalytic Effect of Electronegative Additives on Removal of Perchloroethylene Vapor from Air by Pulsed Corona Discharge

    NASA Astrophysics Data System (ADS)

    Filatov, I. E.; Uvarin, V. V.; Kuznetsov, D. L.

    2017-12-01

    It is established that electronegative additives (CCl4, freon-113) produce a catalytic effect on the conversion of volatile organic compounds (VOCs) under the action of atmospheric-pressure nonequilibrium plasma generated in pulsed corona discharge. At concentrations below 0.1%, these additives significantly decrease the discharge current, but the energy efficiency of the process of VOC removal from air increases. The catalytic effect of electronegative additives on the VOC conversion in air and nitrogen is quantitatively demonstrated in the case of perchloroethylene C2Cl4 (PCE) vapor removal. The addition of 0.085% CCl4 to air reduces the energy consumption for PCE removal at initial concentration of 0.09% by half (from 12 to 6 eV per molecule) at a 63% degree of cleaning. Mechanisms explaining the active inf luence of electronegative additives on the discharge current and the process of impurity removal are suggested.

  7. 76 FR 26768 - Notice of Lodging of a Consent Decree Under The Clean Water Act, The Clean Air Act, and The...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-09

    ... BP Exploration (Alaska) Inc. (``BPXA'')'s operation of oil pipelines on the North Slope of Alaska... Consent Decree in United States v. BP Exploration (Alaska) Inc., Civil Action No. 3:09-CV-00064-JWS was..., 1321, as amended by the Oil Pollution Act of 1990, 33 U.S.C. 2701 et seq.; the Clean Air Act (CAA), 42...

  8. Novel Laser Ablation Technology for Surface Decontamination

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, Chung H.

    2004-06-01

    Laser ablation for surface cleaning has been pursued for the removal of paint on airplanes. It has also been pursued for the cleaning of semiconductor surfaces. However, all these approaches have been pursued by laser ablation in air. For highly contaminated surface, laser ablation in air can easily cause secondary contamination. Thus it is not suitable to apply to achieve surface decontamination for DOE facilities since many of these facilities have radioactive contaminants on the surface. Any secondary contamination will be a grave concern. The objective of this project is to develop a novel technology for laser ablation in liquidmore » for surface decontamination. It aims to achieve more efficient surface decontamination without secondary contamination and to evaluate the economic feasibility for large scale surface decontamination with laser ablation in liquid. When laser ablation is pursued in the solution, all the desorbed contaminants will be confined in liquid. The contaminants can be precipitated and subsequently contained in a small volume for disposal. It can reduce the risk of the decontamination workers. It can also reduce the volume of contaminants dramatically.« less

  9. 75 FR 59973 - Approval and Promulgation of Air Quality Implementation Plans; Maryland; Control of Volatile...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-09-29

    ...; Cleaning of high precision optics; Stripping; Janitorial cleaning; cleaning of resin, coating, ink, and... laboratories; Cleaning operations in medical device or pharmaceutical manufacturing; and Cleaning operations related to performance or quality assurance testing of coatings, inks, or adhesives. COMAR 26.11.19.09-1...

  10. 48 CFR 2823.107 - Compliance responsibilities.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... SOCIOECONOMIC PROGRAMS ENVIRONMENT, CONSERVATION, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Pollution Control and Clean Air and Water 2823.107 Compliance responsibilities. If a contracting officer becomes aware of noncompliance with clean air, water or other affected media standards in facilities used in...

  11. 48 CFR 2823.107 - Compliance responsibilities.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Programs ENVIRONMENT, CONSERVATION, OCCUPATIONAL SAFETY, AND DRUG-FREE WORKPLACE Pollution Control and Clean Air and Water 2823.107 Compliance responsibilities. If a contracting officer becomes aware of noncompliance with clean air, water or other affected media standards in facilities used in performing nonexempt...

  12. 40 CFR 35.501 - Environmental programs covered by the subpart.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Program Act of 1992, 42 U.S.C. 4368b. (3) Clean Air Act. Air pollution control (section 105). (4) Clean... Substances Control Act. (i) Lead-based paint program (section 404(g)). (ii) Indoor radon grants (section 306...

  13. 40 CFR 35.501 - Environmental programs covered by the subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Program Act of 1992, 42 U.S.C. 4368b. (3) Clean Air Act. Air pollution control (section 105). (4) Clean... Substances Control Act. (i) Lead-based paint program (section 404(g)). (ii) Indoor radon grants (section 306...

  14. 76 FR 30604 - Approval of the Clean Air Act, Section 112(l), Authority for Hazardous Air Pollutants...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-26

    ... Maine Department of Environmental Protection's (``ME DEP'') request to implement and enforce the amended... Cleaning NESHAP''), as it applies to area sources. This approval would make the ME DEP's amended rule...

  15. Final Report to the Clean Air Act Advisory Committee, Title V Implementation Experience

    EPA Pesticide Factsheets

    In 2004, the Clean Air Act Advisory Committee established the Task Force on Title V Implementation Experience to report on stakeholder experience with implementation of the Title V operating permit program. This report details their recommendations.

  16. Agenda and Presentations from Circumpolar Workshop: Transport and Clean Air

    EPA Pesticide Factsheets

    EPA and its partners convened Transport and Clean Air, a Circumpolar Workshop held in December 2013. This seminar allowed leading experts to share best practices on reducing emissions of particulates and black carbon from diesel sources in the Arctic.

  17. Developing self-cleaning and air purifying transportation infrastructure components to minimize environmental impact of transportation.

    DOT National Transportation Integrated Search

    2013-10-01

    Creating transportation infrastructure, which can clean up itself and contaminated air surrounding it, can be a : groundbreaking approach in addressing environmental challenges of our time. This project has explored a possibility of : depositing coat...

  18. Summary of Waiver Requests Under Section 211(f) of the Clean Air Act

    EPA Pesticide Factsheets

    This document summarizes the waiver requests that EPA has received under Section 211(f) of the Clean Air Act, including docket numbers, federal register citations, and the actions that were taken by EPA for each request.

  19. GEOINFORMATION AND REGIONAL VULNERABILITY ASSESSMENT (REVA)

    EPA Science Inventory

    Since its inception in 1970, the United States Environmental Protection Agency (EPA) has monitored air, water, land and human health. Currently, EPA's mission is centered on a set five goals: Clean Air, Clean Water, Land Preservation, Healthy Communities, and Stewardship. As pa...

  20. Comprehensive assessment of toxic emissions from coal-fired power plants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1996-09-01

    The 1990 Clean Air Act Amendments (CAAA) have two primary goals: pollution prevention and a market-based least-cost approach to emission control. To address air quality issues as well as permitting and enforcement, the 1990 CAAA contain 11 sections or titles. The individual amendment titles are as follows: Title I - National Ambient Air Quality Standards Title II - Mobile Sources Title III - Hazardous Air Pollutants Title IV - Acid Deposition Control Title V - Permits Title VI - Stratospheric Ozone Protection Chemicals Title VII - Enforcement Title VIII - Miscellaneous Provisions Title IX - Clean Air Research Title Xmore » - Disadvantaged Business Concerns Title XI - Clean Air Employment Transition Assistance Titles I, III, IV, and V will change or have the potential to change how operators of coal-fired utility boilers control, monitor, and report emissions. For the purpose of this discussion, Title III is the primary focus.« less

  1. Austin Clean Cities: Implementing a voluntary alternative fuel program in an attainment area, or getting our act together and taking it on the road

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannemann, L.W.

    1995-12-31

    Austin is the only city in attainment that has chosen to join the Clean Cities program. A recent emissions inventory completed by the City`s Air Quality Program shows that the largest single contributor to Austin`s deteriorating air quality is on-road mobile sources. Implementing the Clean Cities Program is one proactive step they are taking to keep the air clean. Although Austin Clean Cities chose to be fuel neutral they have found that propane and natural gas are the natural choices for them to use. The author was asked to address the potential pitfalls in setting up a Clean Cities program,more » and 20/20 hindsight reveals that Austin had a few housekeeping chores to attend to before starting the real work. There are lots of little details necessary to get an organization like this up and running and then keeping it healthy. These details need to be identified and addressed upfront and before any real work can be done. The advantage is that one gets a network that is able to gather, evaluate and disseminate information, and one gets a clean city.« less

  2. Novel Hollow Fiber Air Filters for the Removal of Ultrafine Particles in PM2.5 with Repetitive Usage Capability.

    PubMed

    Li, Manqing; Feng, Yingnan; Wang, Kaiyu; Yong, Wai Fen; Yu, Liya; Chung, Tai-Shung

    2017-09-05

    Severe air pollution has become a global concern, and there is a pressing need to develop effective and efficient air filters for removing airborne particulate matters (PMs). In this work, a highly permeable poly(ether sulfone) (PES) based hollow fiber membrane was developed via a one-step dry-jet wet spinning. For the first time, a hollow fiber membrane was used in removing the ultrafine particles (PMs with aerodynamic equivalent diameters of less than 100 nm) in PM 2.5 . The novel air filter was designed to possess the synergistic advantages of porous filters and fibrous filters with a sievelike outer surface and a fibrouslike porous substrate. A filtration efficiency of higher than 99.995% could be easily achieved when the self-support hollow fiber was challenged with less than 300 nm particulates. Without losses of the structural advantages, we have demonstrated that the permeation properties of the hollow fiber membrane can be facilely tailored via manipulation of the dope and bore fluid formulations. Various cleaning strategies were explored to regenerate the membrane performance after fouling. Both water rinse and backwash showed effectiveness to restore the membrane permeance for repetitive usage.

  3. 75 FR 47627 - Notice of Lodging of Proposed Consent Decree With Hoosier Energy Rural Electric Cooperative, Inc...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-06

    ... Electric Cooperative, Inc. Under The Clean Air Act Pursuant to 28 CFR 50.7, notice is hereby given that on... the federal Clean Air Act (``Act''), the United States and the State of Indiana allege that Hoosier--an electric utility--failed to comply with certain requirements of the Act intended to protect air...

  4. The North Carolina Department of Environment and Natural Resources: clean land, water, and air for healthy people and communities.

    PubMed

    Riegel, Lisa Diaz; Wakild, Charles; Boothe, Laura; Hildebrandt, Heather J; Nicholson, Bruce

    2012-01-01

    The North Carolina Department of Environment and Natural Resources works with communities and other agencies to sustain clean air, water, and land. Sustainability efforts include protecting air quality through community design, community enhancement through brownfields revitalization, community development strategies to protect water resources, and the integration of natural resource conservation.

  5. 75 FR 63471 - Science Advisory Board Staff Office; Notification of a Public Teleconference of the Clean Air...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-10-15

    ... Monitoring and Methods Subcommittee (AAMMS) and a draft report from the CASAC Oxides of Nitrogen (NO X ) and Sulfur Oxides (SO X ) Secondary National Ambient Air Quality Standards (NAAQS) Review Panel. DATES: The... in 75 FR 54871-54872, the Clean Air Scientific Advisory Committee NO X and SO X Secondary National...

  6. Innovative Instrumentation and Analysis of the Temperature Measurement for High Temperature Gasification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seong W. Lee

    The project entitled, ''Innovative Instrumentation and Analysis of the Temperature Measurement for High Temperature Gasification'', was successfully completed by the Principal Investigator, Dr. S. Lee and his research team in the Center for Advanced Energy Systems and Environmental Control Technologies at Morgan State University. The major results and outcomes were presented in semi-annual progress reports and annual project review meetings/presentations. Specifically, the literature survey including the gasifier temperature measurement, the ultrasonic application in cleaning application, and spray coating process and the gasifier simulator (cold model) testing has been successfully conducted during the first year. The results show that four factorsmore » (blower voltage, ultrasonic application, injection time intervals, particle weight) were considered as significant factors that affect the temperature measurement. Then the gasifier simulator (hot model) design and the fabrication as well as the systematic tests on hot model were completed to test the significant factors on temperature measurement in the second year. The advanced Industrial analytic methods such as statistics-based experimental design, analysis of variance (ANOVA) and regression methods were applied in the hot model tests. The results show that operational parameters (i.e. air flow rate, water flow rate, fine dust particle amount, ammonia addition) presented significant impact on the temperature measurement inside the gasifier simulator. The experimental design and ANOVA are very efficient way to design and analyze the experiments. The results show that the air flow rate and fine dust particle amount are statistically significant to the temperature measurement. The regression model provided the functional relation between the temperature and these factors with substantial accuracy. In the last year of the project period, the ultrasonic and subsonic cleaning methods and coating materials were tested/applied on the thermocouple cleaning according to the proposed approach. Different frequency, application time and power of the ultrasonic/subsonic output were tested. The results show that the ultrasonic approach is one of the best methods to clean the thermocouple tips during the routine operation of the gasifier. In addition, the real time data acquisition system was also designed and applied in the experiments. This advanced instrumentation provided the efficient and accurate data acquisition for this project. In summary, the accomplishment of the project provided useful information of the ultrasonic cleaning method applied in thermocouple tip cleaning. The temperature measurement could be much improved both in accuracy and duration provided that the proposed approach is widely used in the gasification facilities.« less

  7. Notification: Review of Inspections and Evaluations of Clean Air Act Sources

    EPA Pesticide Factsheets

    Project #OPE-FY15-0015, March 12, 2015. The EPA OIG plans to begin preliminary research of the Office of Enforcement and Compliance Assurance (OECA) and selected EPA region's oversight of compliance assurance activities for major Clean Air Act sources.

  8. A summary : transportation programs and provisions of the Clean Air Act Amendments of 1990

    DOT National Transportation Integrated Search

    1992-01-01

    To achieve the goals of the Clean Air Act Amendments of 1990 (CAAA), State and local officials must first understand the requirements for transportation plans, programs, and projects. The Federal Highway Administration (FHWA) has prepared this brochu...

  9. Clean Air Act Amendments of 2010

    THOMAS, 111th Congress

    Sen. Carper, Thomas R. [D-DE

    2010-02-04

    Senate - 03/04/2010 Committee on Environment and Public Works Senate Subcommittee on Clean Air and Nuclear Safety. Hearings held. With printed Hearing: S.Hrg. 111-1228. (All Actions) Tracker: This bill has the status IntroducedHere are the steps for Status of Legislation:

  10. Halogenated Solvent Cleaning Compliance Assistance Memoranda for the National Emission Standards for Hazardous Air Pollutants (NESHAP)

    EPA Pesticide Factsheets

    This page contains three documents, one from 1997, one from 1999, and one from 2001, that provide further clarification on complying with the National Emission Standards for Hazardous Air Pollutants (NESHAP) for Halogenated Solvent Cleaning.

  11. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  12. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  13. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  14. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  15. 40 CFR 90.5 - Acronyms and abbreviations.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Materials CAA—Clean Air Act CAAA—Clean Air Act Amendments of 1990 CLD—chemiluminescent detector CO—Carbon... per kilowatt hour HC—hydrocarbons HCLD—heated chemiluminescent detector HFID—heated flame ionization detector ICI—independent Commercial Importer NDIR—non-dispersive infrared analyzer NIST—National Institute...

  16. Efficient and reusable polyamide-56 nanofiber/nets membrane with bimodal structures for air filtration.

    PubMed

    Liu, Bowen; Zhang, Shichao; Wang, Xueli; Yu, Jianyong; Ding, Bin

    2015-11-01

    Nanofibrous media that both possess high airborne particle interception efficiency and robust air permeability would have broad technological implications for areas ranging from individual protection and industrial security to environmental governance; however, creating such filtration media has proved extremely challenging. Here we report a strategy to construct the bio-based polyamide-56 nanofiber/nets (PA-56 NFN) membranes with bimodal structures for effective air filtration via one-step electrospinning/netting. The PA-56 membranes are composed of completely covered two-dimensional (2D) ultrathin (∼20 nm) nanonets which are optimized by facilely regulating the solution concentration, and the bonded scaffold fibers constructed cavity structures which are synchronously created by using the CH3COOH inspiration. With integrated properties of small aperture, high porosity, and bonded scaffold, the resulting PA-56 NFN membranes exhibit high filtration efficiency of 99.995%, low pressure drop of 111 Pa, combined with large dust holding capacity of 49 g/m(2) and dust-cleaning regeneration ability, for filtrating ultrafine airborne particles in the most safe manner involving sieving principle and surface filtration. The successful synthesis of PA-56 NFN medium would not only make it a promising candidate for air filtration, but also provide new insights into the design and development of nanonet-based bimodal structures for various applications. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Cleaning mechanism of particle contaminants on large aperture optical components by using air knife sweeping technology

    NASA Astrophysics Data System (ADS)

    Niu, Longfei; Liu, Hao; Miao, Xinxiang; Lv, Haibing; Yuan, Xiaodong; Zhou, Hai; Yao, Caizhen; Zhou, Guorui; Li, Qin

    2017-05-01

    The cleaning mechanism of optical surface particle contaminants in the light pneumatic tube was simulated based on the static equations and JKR model. Cleaning verification experiment based on air knife sweeping system and on-line monitoring system in high power laser facility was set up in order to verify the simulated results. Results showed that the removal ratio is significantly influenced by sweeping velocity and angle. The removal ratio can reach to 94.3% by using higher input pressure of the air knife, demonstrating that the air knife sweeping technology is useful for maintaining the surface cleanliness of optical elements, and thus guaranteeing the long-term stable running of the high power laser facility.

  18. Clean Air Markets - Where You Live (National and State Maps)

    EPA Pesticide Factsheets

    Where You Live accesses facility and unit attribute data as well as emissions data using a series of interactive national and state maps. This module allows the user to view data for regions of interest throughout the country using an intuitive interface, while also providing a national and statewide context for data specific to one or more facilities.EPA's Clean Air Markets Division (CAMD) includes several market-based regulatory programs designed to improve air quality and ecosystems. The most well-known of these programs are EPA's Acid Rain Program and the NOx Programs, which reduce emissions of sulfur dioxide (SO2) and nitrogen oxides (NOx)-compounds that adversely affect air quality, the environment, and public health. CAMD also plays an integral role in the development and implementation of the Clean Air Interstate Rule (CAIR).

  19. JSF/F-35 Pollution Prevention Activities

    DTIC Science & Technology

    2006-05-01

    Liquid Oxygen •Produces Oxygen-Rich Breathing Gas From Engine Bleed Air Using Molecular Sieve Technology •No Exotic Cleaning Solutions •Military No...Explosion from Bullets/Shrapnel •On-Board Inert Gas Generating System (OBIGGS) Replaced Halon 1301 •Filters out Oxygen from Ambient Air to Create...Supply System •Supply System Must Be Perfectly Clean •Best Cleaning Solutions Freon CFC-113 and HCFC-141b •On-Board Oxygen Generating System Replaced

  20. Performance analysis of a bio-gasification based combined cycle power plant employing indirectly heated humid air turbine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mukherjee, S., E-mail: sankha.deepp@gmail.com; Mondal, P., E-mail: mondal.pradip87@gmail.com; Ghosh, S., E-mail: sudipghosh.becollege@gmail.com

    Rapid depletion of fossil fuel has forced mankind to look into alternative fuel resources. In this context, biomass based power generation employing gas turbine appears to be a popular choice. Bio-gasification based combined cycle provides a feasible solution as far as grid-independent power generation is concerned for rural electrification projects. Indirectly heated gas turbine cycles are promising alternatives as they avoid downstream gas cleaning systems. Advanced thermodynamic cycles have become an interesting area of study to improve plant efficiency. Water injected system is one of the most attractive options in this field of applications. This paper presents a theoretical modelmore » of a biomass gasification based combined cycle that employs an indirectly heated humid air turbine (HAT) in the topping cycle. Maximum overall electrical efficiency is found to be around 41%. Gas turbine specific air consumption by mass is minimum when pressure ratio is 6. The study reveals that, incorporation of the humidification process helps to improve the overall performance of the plant.« less

  1. 40 CFR 423.11 - Specialized definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... air conditioning wastes are not included. (c) The term chemical metal cleaning waste means any wastewater resulting from the cleaning of any metal process equipment with chemical compounds, including, but... from cleaning [with or without chemical cleaning compounds] any metal process equipment including, but...

  2. First Clean Air Act Benefits and Costs Prospective Study - Press Release November 16, 1999

    EPA Pesticide Factsheets

    The economic value of the public health and environmental benefits that Americans enjoy from the Clean Air Act Amendments of 1990 exceed their costs by a margin of four to one, according to this EPA study released in 1999.

  3. RESULTS FROM THE MOUNTAIN ACID DEPOSITION PROGRAM

    EPA Science Inventory

    The Mountain Acid Deposition Program (MADPro) was initiated in 1993 as part of the research necessary to support the objectives of the Clean Air Status and Trends Network (CASTNet), which was created to address the. requirements of the Clean Air Act Amendments (CAAA). The main ob...

  4. Risk Management Programs under Clean Air Act Section 112(r): Guidance for Implementing Agencies

    EPA Pesticide Factsheets

    Accidental release prevention programs under section 112(r) of the Clean Air Act (CAA) are related to and build on activities under the Emergency Planning and Community Right-to-Know Act, and Occupational Safety and Health Administration standards.

  5. Sterilization of bacterial endospores by an atmospheric-pressure argon plasma jet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Uhm, Han S.; Lim, Jin P.; Li, Shou Z.

    2007-06-25

    Argon plasma jets penetrate deep into ambient air and create a path for oxygen radicals to sterilize microbes. A sterilization experiment with bacterial endospores indicates that an argon-oxygen plasma jet very effectively kills endospores of Bacillus atrophaeus (ATCC 9372), thereby demonstrating its capability to clean surfaces and its usefulness for reinstating contaminated equipment as free from toxic biological warfare agents. However, the spore-killing efficiency of the atmospheric-pressure argon-oxygen jet depends very sensitively on the oxygen concentration in the argon gas.

  6. Cracow clean fossil fuels and energy efficiency program. Progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    1998-10-01

    Since 1990 the US Department of Energy has been involved in a program aimed at reducing air pollution caused by small, coal-fired sources in Poland. The program focuses on the city of Cracow and is designed so that results will be applicable and extendable to the entire region. This report serves both as a review of the progress which has been made to date in achieving the program objectives and a summary of work still in progress.

  7. CRACOW CLEAN FOSSIL FUELS AND ENERGY EFFICIENCY PROGRAM. PROGRESS REPORT, OCTOBER 1998

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PIERCE,B.

    1998-10-01

    Since 1990 the US Department of Energy has been involved in a program aimed at reducing air pollution caused by small, coal-fired sources in Poland. The program focuses on the city of Cracow and is designed so that results will be applicable and extendable to the entire region. This report serves both as a review of the progress which has been made to date in achieving the program objectives and a summary of work still in progress.

  8. Use of a land-use-based emissions inventory in delineating clean-air zones

    Treesearch

    Victor S. Fahrer; Howard A. Peters

    1977-01-01

    Use of a land-use-based emissions inventory from which air-pollution estimates can be projected was studied. First the methodology used to establish a land-use-based emission inventory is described. Then this inventory is used as input in a simple model that delineates clean air and buffer zones. The model is applied to the town of Burlington, Massachusetts....

  9. 75 FR 32763 - Science Advisory Board Staff Office; Notification of a Public Meeting of the Clean Air Scientific...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-09

    ...The Environmental Protection Agency (EPA) Science Advisory Board (SAB) Staff Office announces a public meeting on July 26-27, 2010 of the Clean Air Scientific Advisory Particulate Matter Review Panel (Panel) to review EPA's forthcoming Policy Assessment for the Review of Particulate Matter National Ambient Air Quality Standards-- Second External Review Draft (June 2010).

  10. International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Drop Testing of Returned Units

    NASA Technical Reports Server (NTRS)

    Green, Robert D.; Agui, Juan H.; Vijayakumar, R.; Berger, Gordon M.; Perry, Jay L.

    2017-01-01

    The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

  11. Filter Efficiency and Pressure Testing of Returned ISS Bacterial Filter Elements (BFEs)

    NASA Technical Reports Server (NTRS)

    Green, Robert D.; Agui, Juan H.; Berger, Gordon M.; Vijayakumar, R.; Perry, Jay L.

    2017-01-01

    The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

  12. Air purification in industrial plants producing automotive rubber components in terms of energy efficiency

    NASA Astrophysics Data System (ADS)

    Grzebielec, Andrzej; Rusowicz, Artur; Szelągowski, Adam

    2017-04-01

    In automotive industry plants, which use injection molding machines for rubber processing, tar contaminates air to such an extent that air fails to enter standard heat recovery systems. Accumulated tar clogs ventilation heat recovery exchangers in just a few days. In the plant in which the research was conducted, tar contamination causes blockage of ventilation ducts. The effect of this phenomenon was that every half year channels had to be replaced with new ones, since the economic analysis has shown that cleaning them is not cost-efficient. Air temperature inside such plants is often, even in winter, higher than 30°C. The air, without any means of heat recovery, is discharged outside the buildings. The analyzed plant uses three types of media for production: hot water, cold water at 14°C (produced in a water chiller), and compressed air, generated in a unit with a rated power consumption of 180 kW. The aim of the study is to determine the energy efficiency improvement of this type of manufacturing plant. The main problem to solve is to provide an air purification process so that air can be used in heat recovery devices. The next problem to solve is to recover heat at such a temperature level that it would be possible to produce cold for technological purposes without air purification. Experimental studies have shown that air purification is feasible. By using one microjet head, a total of 75% of tar particles was removed from the air; by using 4 heads, a purification efficiency of 93% was obtained. This method of air purification causes air temperature to decrease from 35°C to 20°C, which significantly reduces the potential for heat recovery. The next step of the research was designing a cassette-plate heat exchanger to exchange heat without air purification. The economic analysis of such a solution revealed that replacing the heat exchanger with a new one even once a year was not cost-efficient. Another issue examined in the context of energy efficiency was the use of waste heat from the air compressor. Before any changes, the heat was picked up by a chilled water system. The idea was to use the heat for cold generation. Temperature of oil and air in the compressor exceeds 65°C, which makes it a perfect heat source for an adsorption refrigeration device. This solution reduced the cooling demand by 147 kW, thus reducing power consumption by 36.75 kW. This study shows that even in factories where air is heavily polluted with tar, there are huge potentials for energy recovery using existing technical solutions. It is important to note that problems of this kind should always be approached individually.

  13. The tropospheric distribution of formaldehyde

    NASA Astrophysics Data System (ADS)

    Lowe, D. C.; Schmidt, U.; Ehhalt, D. H.

    1981-12-01

    A measurement technique for determining the very low formaldehyde concentrations in clean air is described. The method is based on the standard derivation of formaldehyde with 2,4-dinitrophenylhydrazine. The derivative is separated, using high performance liquid chromatography, and detected at 254 nm with a conventional UV absorption detector. The sampling and analysis technique was used to measure tropospheric mixing ratios at various places in Europe and New Zealand as well as during a cruise in the North and South Atlantic. The results of the measurements show that formaldehyde mixing ratios in clean air are very low. In clean maritime air no significant difference in the formaldehyde mixing ratio between the hemispheres is observed.

  14. The Benefits and Costs of the Clean Air Act 1990 to 2010: EPA Report to Congress (1999)

    EPA Pesticide Factsheets

    The study is the second in a series of EPA cost/benefit Reports to Congress examining the effects of the Clean Air Act on the U.S. economy, public health, and the environment for the period 1990-2010.

  15. The Economics of Clean Air - Annual Report to the Congress of the United States (1972)

    EPA Pesticide Factsheets

    The fourth EPA report submitted under Section 312 of the Clean Air Act Amendments of 1970, which requires an annual report on the prospective costs and impacts of governmental and private efforts to carry out the provisions of the Act.

  16. 36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    36. FIFTH FLOOR BLDG. 27, "CLEAN ROOM" AIR FILTERS LOOKING SOUTH. - Fafnir Bearing Plant, Bounded on North side by Myrtle Street, on South side by Orange Street, on East side by Booth Street & on West side by Grove Street, New Britain, Hartford County, CT

  17. National Emission Standards for Hazardous Air Pollutants (NESHAP) for Source Categories: Perchloroethylene Dry Cleaning Facilities - 1993 Final Rule (58 FR 49354)

    EPA Pesticide Factsheets

    This document is a copy of the Federal Register publication of the September 22, 1993 Final Rule for the National Emission Standards for Hazardous Air Pollutants for Source Categories: Perchloroethylene Dry Cleaning Facilities.

  18. 77 FR 37038 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for CF&I...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-20

    ... title V of the Clean Air Act (Act) by WildEarth Guardians (Petitioner), to object to CDPHE's December 28.... EPA received a petition from WildEarth Guardians dated March 24, 2011, requesting that EPA object to...

  19. 78 FR 78384 - Notice of Filing of Proposed Consent Decree Under the Clean Air Act

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... the Clean Air Act, 42 U.S.C. 7412(r)(1), with respect to two of its titanium and zirconium processing... zirconium, or 2.4 million pounds, being stored at facilities in New Cumberland and Weirton, WV by December...

  20. Cleaning products and air fresheners: emissions and resulting concentrations of glycol ethers and terpenoids.

    PubMed

    Singer, B C; Destaillats, H; Hodgson, A T; Nazaroff, W W

    2006-06-01

    Experiments were conducted to quantify emissions and concentrations of glycol ethers and terpenoids from cleaning product and air freshener use in a 50-m3 room ventilated at approximately 0.5/h. Five cleaning products were applied full-strength (FS); three were additionally used in dilute solution. FS application of pine-oil cleaner (POC) yielded 1-h concentrations of 10-1300 microg/m3 for individual terpenoids, including alpha-terpinene (90-120), d-limonene (1000-1100), terpinolene (900-1300), and alpha-terpineol (260-700). One-hour concentrations of 2-butoxyethanol and/or d-limonene were 300-6000 microg/m3 after FS use of other products. During FS application including rinsing with sponge and wiping with towels, fractional emissions (mass volatilized/dispensed) of 2-butoxyethanol and d-limonene were 50-100% with towels retained, and approximately 25-50% when towels were removed after cleaning. Lower fractions (2-11%) resulted from dilute use. Fractional emissions of terpenes from FS use of POC were approximately 35-70% with towels retained, and 20-50% with towels removed. During floor cleaning with dilute solution of POC, 7-12% of dispensed terpenes were emitted. Terpene alcohols were emitted at lower fractions: 7-30% (FS, towels retained), 2-9% (FS, towels removed), and 2-5% (dilute). During air-freshener use, d-limonene, dihydromyrcenol, linalool, linalyl acetate, and beta-citronellol) were emitted at 35-180 mg/day over 3 days while air concentrations averaged 30-160 microg/m3. While effective cleaning can improve the healthfulness of indoor environments, this work shows that use of some consumer cleaning agents can yield high levels of volatile organic compounds, including glycol ethers--which are regulated toxic air contaminants--and terpenes that can react with ozone to form a variety of secondary pollutants including formaldehyde and ultrafine particles. Persons involved in cleaning, especially those who clean occupationally or often, might encounter excessive exposures to these pollutants owing to cleaning product emissions. Mitigation options include screening of product ingredients and increased ventilation during and after cleaning. Certain practices, such as the use of some products in dilute solution vs. full-strength and the prompt removal of cleaning supplies from occupied spaces, can reduce emissions and exposures to 2-butoxyethanol and other volatile constituents. Also, it may be prudent to limit use of products containing ozone-reactive constituents when indoor ozone concentrations are elevated either because of high ambient ozone levels or because of the indoor use of ozone-generating equipment.