Sample records for elasticity difference strapped

  1. Effect of a novel insole on the subtalar joint of patients with medial compartment osteoarthritis of the knee.

    PubMed

    Toda, Y; Segal, N; Kato, A; Yamamoto, S; Irie, M

    2001-12-01

    To assess the efficacy of a lateral wedge insole with elastic strapping of the subtalar joint for conservative treatment of osteoarthritis (OA) of the knee. The efficacy of a novel insole with elastic subtalar strapping and a traditional shoe insert wedge insole was compared. Ninety female outpatients with OA of the knee were treated with wedge insoles for 8 weeks. Randomization was performed according to birth date. Standing radiographs with unilateral insole use were used to analyze the femorotibial and talar tilt angles for each patient with and without their respective insole. Visual analog scale (VAS) score for subjective knee pain at the final assessment was compared with that at baseline in both groups. Participants wearing the elastically strapped insole (n = 46) had significantly decreased femorotibial angle (p < 0.0001) and talar tilt angle (p = 0.005) and significantly improved VAS pain score (p = 0.045) in comparison with baseline assessments. These significant differences were not found in the group with the inserted insole (n = 44). The novel strapped insole leads to valgus angulation of the talus, resulting in correction of the femorotibial angle in patients with knee OA with varus deformity, and may have a therapeutic effect similar to that of high tibial osteotomy.

  2. Two-Arm Flexible Thermal Strap

    NASA Technical Reports Server (NTRS)

    Urquiza, Eugenio; Vasquez, Cristal; Rodriquez, Jose I.; Leland, Robert S.; VanGorp, Byron E.

    2011-01-01

    Airborne and space infrared cameras require highly flexible direct cooling of mechanically-sensitive focal planes. A thermal electric cooler is often used together with a thermal strap as a means to transport the thermal energy removed from the infrared detector. While effective, traditional thermal straps are only truly flexible in one direction. In this scenario, a cooling solution must be highly conductive, lightweight, able to operate within a vacuum, and highly flexible in all axes to accommodate adjustment of the focal plane while transmitting minimal force. A two-armed thermal strap using three end pieces and a twisted section offers enhanced elastic movement, significantly beyond the motion permitted by existing thermal straps. This design innovation allows for large elastic displacements in two planes and moderate elasticity in the third plane. By contrast, a more conventional strap of the same conductance offers less flexibility and asymmetrical elasticity. The two-arm configuration reduces the bending moment of inertia for a given conductance by creating the same cross-sectional area for thermal conduction, but with only half the thickness. This reduction in the thickness has a significant effect on the flexibility since there is a cubic relationship between the thickness and the rigidity or bending moment of inertia. The novelty of the technology lies in the mechanical design and manufacturing of the thermal strap. The enhanced flexibility will facilitate cooling of mechanically sensitive components (example: optical focal planes). This development is a significant contribution to the thermal cooling of optics. It is known to be especially important in the thermal control of optical focal planes due to their highly sensitive alignment requirements and mechanical sensitivity; however, many other applications exist including the cooling of gimbal-mounted components.

  3. A six-month followup of a randomized trial comparing the efficacy of a lateral-wedge insole with subtalar strapping and an in-shoe lateral-wedge insole in patients with varus deformity osteoarthritis of the knee.

    PubMed

    Toda, Yoshitaka; Tsukimura, Noriko

    2004-10-01

    To assess the effect of a lateral-wedge insole with elastic strapping of the subtalar joint on the femorotibial angle in patients with varus deformity of the knee. The efficacy of a wedged insole with subtalar straps and that of a traditional wedged insole shoe insert were compared. Sixty-six female outpatients with knee osteoarthritis (OA) were randomized (according to birth date) to be treated with either the strapped or the traditional inserted insole. Standing radiographs with unilateral insole use were used to analyze the femorotibial angles for each patient. In both groups, the baseline and 6-month visual analog scale (VAS) scores for subjective knee pain and the Lequesne index scores for knee OA were compared. The 61 patients who completed the 6-month study were evaluated. At baseline, there was no significant difference in the femorotibial angle (P = 0.66) and the VAS score (P = 0.75) between the 2 groups. At the 6-month assessment, the 29 subjects wearing the subtalar-strapped insole demonstrated a significantly decreased femorotibial angle (P < 0.0001) and significantly improved VAS scores (P = 0.001) and Lequesne index scores (P = 0.033) compared with their baseline assessments. These significant differences were not observed in the 32 subjects assigned to the traditional shoe-inserted wedged insole. These results suggest that an insole with a subtalar strap maintained the valgus correction of the femorotibial angle in patients with varus knee OA for 6 months, indicating longer-term clinical improvement with the strapped insert compared with the traditional insert. Copyright 2004 American College of Rheumatology

  4. How kelp produce blade shapes suited to different flow regimes: A new wrinkle.

    PubMed

    Koehl, M A R; Silk, W K; Liang, H; Mahadevan, L

    2008-12-01

    Many species of macroalgae have flat, strap-like blades in habitats exposed to rapidly flowing water, but have wide, ruffled "undulate" blades at protected sites. We used the giant bull kelp, Nereocystis luetkeana, to investigate how these ecomorphological differences are produced. The undulate blades of N. luetkeana from sites with low flow remain spread out and flutter erratically in moving water, thereby not only enhancing interception of light, but also increasing drag. In contrast, strap-like blades of kelp from habitats with rapid flow collapse into streamlined bundles and flutter at low amplitude in flowing water, thus reducing both drag and interception of light. Transplant experiments in the field revealed that shape of the blade in N. luetkeana is a plastic trait. Laboratory experiments in which growing blades from different sites were subjected to tensile forces that mimicked the hydrodynamic drag experienced by blades in different flow regimes showed that change in shape is induced by mechanical stress. During growth experiments in the field and laboratory, we mapped the spatial distribution of growth in both undulate and strap-like blades to determine how these different morphologies were produced. The highest growth rates occur near the proximal ends of N. luetkeana blades of both morphologies, but the rates of transverse growth of narrow, strap-like blades are lower than those of wide, undulate blades. If rates of longitudinal growth at the edges of a blade exceed the rate of longitudinal growth along the midline of the blade, ruffles along the edges of the blade are produced by elastic buckling. In contrast, flat blades are produced when rates of longitudinal growth are similar across the width of a blade. Because ruffles are the result of elastic buckling, a compliant undulate N. luetkeana blade can easily be pushed into different configurations (e.g., the wavelengths of the ruffles along the edges of the blade can change, and the whole blade can twist into left- and right-handed helicoidal shapes), which may enhance movements of the blade in flowing water that reduce self-shading and increase mass exchange along blade surfaces.

  5. Method for computing energy release rate using the elastic work factor approach

    NASA Astrophysics Data System (ADS)

    Rhee, K. Y.; Ernst, H. A.

    1992-01-01

    The elastic work factor eta(el) concept was applied to composite structures for the calculation of total energy release rate by using a single specimen. Cracked lap shear specimens with four different unidirectional fiber orientation were used to examine the dependence of eta(el) on the material properties. Also, three different thickness ratios (lap/strap) were used to determine how geometric conditions affect eta(el). The eta(el) values were calculated in two different ways: compliance method and crack closure method. The results show that the two methods produce comparable eta(el) values and, while eta(el) is affected significantly by geometric conditions, it is reasonably independent of material properties for the given geometry. The results also showed that the elastic work factor can be used to calculate total energy release rate using a single specimen.

  6. Bra strap orientations and designs to minimise bra strap discomfort and pressure during sport and exercise in women with large breasts.

    PubMed

    Coltman, Celeste E; McGhee, Deirdre E; Steele, Julie R

    2015-01-01

    Bra straps are a primary source of discomfort during sport and exercise, particularly for women with large breasts. This study aimed to investigate the effects of altering bra strap orientation and design on bra strap comfort, pressure and breast support in women with large breasts. This is a descriptive laboratory study. Bra strap discomfort (visual analogue scale, 0 to 10), pressure (custom-designed 10 mm 2 calibrated pressure sensor, 0.5 to 24 kPa range, 50 Hz, S2011, Novel GmbH, Munich, Germany, placed under the right bra strap at the crest of each participant's shoulder), preference ranking and vertical breast displacement (VBD; Optotrak Certus® motion capture system, 200 Hz, Northern Digital, Ontario, Canada) data during dynamic treadmill running and static upright standing (pressure only) were collected for 23 active women with large breasts (D+ cup size) while they wore an encapsulation sports bra with six different bra strap conditions (two bra strap orientations: vertical and cross-back; three bra strap designs: standard width, wide and gel). Bra strap discomfort was significantly less ( p  ≤ 0.001) in the vertical compared to the cross-back strap orientation, which was the most preferred orientation despite no significant difference in strap pressure. The wide strap design had the lowest discomfort scores, significantly lower strap pressure compared to the standard width and gel strap designs ( p  < 0.001), and was equally the most preferred design with the gel straps. There was no significant difference in VBD among the six strap conditions. Bra straps that are vertically orientated and wide (approximately 4.5 cm in width) are preferable for women with large breasts during sport and exercise to minimise bra strap pressure and discomfort. The addition of gel pads under bra straps may also decrease discomfort and prevent straps slipping off the shoulders, although this notion warrants further investigation.

  7. The Effects of Bag Style on Muscle Activity of the Trapezius, Erector Spinae and Latissimus Dorsi During Walking in Female University Students

    PubMed Central

    Hardie, Rebecca; Haskew, Rachel; Harris, Joel; Hughes, Gerwyn

    2015-01-01

    Back pain is common in adolescents which has been associated with carrying a bag. However, there is little research examining the effects of bag style in female adolescents. The aim of the study was to investigate the effects of different bag conditions on muscle activity of the trapezius, erector spinae and latissimus dorsi muscles in female university students during walking. Twelve female university students walked on a treadmill for 5 minutes at 1.1 m/s during five conditions; control, 1 strapped rucksack, 2 strapped rucksack, ipsilateral shoulder strap and contralateral shoulder strap, each containing 10% bodyweight. Electromyography for the trapezius, erector spinae and latissimus dorsi was recorded for the last 30 s of each condition. Two-way ANOVA and paired t-tests were used to identify differences between right and left muscles and between bag conditions. Results showed that muscle activity of the left trapezius was significantly higher than the right trapezius during the 1 strap rucksack condition. For the left trapezius, the 2 strapped rucksack and the control condition had significantly lower muscle activity compared to the 1 strapped rucksack and the ipsilateral shoulder strap. For the left erector spinae muscle, there was significantly greater muscle activity when wearing the contralateral shoulder strap compared to the control. For the right erector spinae, significantly lower muscle activity was observed when wearing the 2 strapped rucksack compared to the ipsilateral shoulder strap and contralateral shoulder strap. There were no significant differences in muscle activity of the latissimus dorsi muscles between any of the bag conditions. These findings suggest that a two strapped rucksack should be used when carrying loads to reduce spinal muscle activity which may, in turn, reduce reports of back pain in female adolescents. PMID:25964808

  8. STRAP regulates c-Jun ubiquitin-mediated proteolysis and cellular proliferation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reiner, Jennifer; Ye, Fei; Kashikar, Nilesh D.

    2011-04-08

    Highlights: {yields} STRAP is specifically correlated with c-Jun expression and activation in fibroblasts. {yields} STRAP inhibits c-Jun ubiquitylation in vivo and prolongs the half-life of c-Jun. {yields} STRAP expression increases expression of the AP-1 target gene, cyclin D1, and promotes cell autonomous growth. -- Abstract: STRAP is a ubiquitous WD40 protein that has been implicated in tumorigenesis. Previous studies suggest that STRAP imparts oncogenic characteristics to cells by promoting ERK and pRb phosphorylation. While these findings suggest that STRAP can activate mitogenic signaling pathways, the effects of STRAP on other MAPK pathways have not been investigated. Herein, we report thatmore » STRAP regulates the expression of the c-Jun proto-oncogene in mouse embryonic fibroblasts. Loss of STRAP expression results in reduced phospho-c-Jun and total c-Jun but does not significantly reduce the level of two other early response genes, c-Myc and c-Fos. STRAP knockout also decreases expression of the AP-1 target gene, cyclin D1, which is accompanied by a reduction in cell growth. No significant differences in JNK activity or basal c-Jun mRNA levels were observed between wild type and STRAP null fibroblasts. However, proteasomal inhibition markedly increases c-Jun expression in STRAP knockout MEFs and STRAP over-expression decreases the ubiquitylation of c-Jun in 293T cells. Loss of STRAP accelerates c-Jun turnover in fibroblasts and ectopic over-expression of STRAP in STRAP null fibroblasts increases c-Jun expression. Collectively, our findings indicate that STRAP regulates c-Jun stability by decreasing the ubiquitylation and proteosomal degradation of c-Jun.« less

  9. Elastic S-matrices in (1 + 1) dimensions and Toda field theories

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Christe, P.; Mussardo, G.

    Particular deformations of 2-D conformal field theory lead to integrable massive quantum field theories. These can be characterized by the relative scattering data. This paper proposes a general scheme for classifying the elastic nondegenerate S-matrix in (1 + 1) dimensions starting from the possible boot-strap processes and the spins of the conserved currents. Their identification with the S-matrix coming from the Toda field theory is analyzed. The authors discuss both cases of Toda field theory constructed with the simply-laced Dynkin diagrams and the nonsimply-laced ones. The authors present the results of the perturbative analysis and their geometrical interpretations.

  10. A comparison of 2 circuit exercise training techniques for eliciting matched metabolic responses in persons with paraplegia.

    PubMed

    Nash, Mark S; Jacobs, Patrick L; Woods, Jeffrey M; Clark, James E; Pray, Tanya A; Pumarejo, Alex E

    2002-02-01

    To test whether acute metabolic (VO(2)), chronotropic (heart rate), and perceptual (rating of perceived exertion; RPE) responses to exercise by persons with paraplegia differ when the exercise is on a multistation isoinertial exercise system (MultiGym) or on a customized system of Thera-Band resistance bands (ElasticGym). Within-subjects comparison of 2 treatments. Academic medical center. Sixteen men and 1 woman with complete paraplegia (T4-L1), as defined by the American Spinal Injury Association. A circuit resistance training (CRT) program for persons with paraplegia was adapted to both a MultiGym and a customized ElasticGym. Exercises used for training and testing used 6 resistance maneuvers at 50% of the 1-repetition maximum (1-RM), with interposed rapid arm spinning. Subjects were habituated to both conditions for 2 weeks before testing on randomized nonconsecutive days. VO(2) (L/min) was measured by portable spirometry, heart rate (beats/min) by a chest strap monitor, and RPE by the Borg Scale of Perceived Exertion (6-20). No significant effects of test condition on average VO(2) or heart rate were observed, with differences between conditions reflecting only .08L/min and 6.4 beats/min, respectively. Average RPE was significantly higher in testing under the ElasticGym condition (P < .05). CRT on a customized ElasticGym system elicited acute metabolic and chronotropic responses that did not differ from responses to exercise on a MultiGym, though RPE was greater with the ElasticGym. Copyright 2002 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation

  11. Using an Elastic Band Device After a Severe Obstetric Pubic Symphyseal Separation: Clinical and Imaging Evaluation.

    PubMed

    Lasbleiz, Jeremy; Sevestre, François-Xavier; Moquet, Pierre-Yves

    2017-09-01

    Severe separation of the pubic symphysis is a rare delivery complication. Facing this pathology, we decided to study a new elastic band device. To evaluate the elastic band device, clinical (pain-rated) and imaging (magnetic resonance imaging and radiography) evaluations with and without the device were performed. The elastic band device is a European Conformity-certified medical device, which is made of neoprene straps, that reduces the mobility of the pelvis and the use of the internal rotator muscles. Once the elastic band device was in place, on postpartum day 1, radiography showed a decrease of the pubic width from 41 to 12 mm. Furthermore, pain decreased from 10 of 10 to 2 of 10 in 2 days, allowing the patient to ambulate and avoid surgery. After 1 month, the pubic width (6 mm) and anatomy were recovered but minor pain was still present with hip rotatory movements. The elastic band device was worn 24 hours a day from postpartum days 1-90 and 12 hours a day from postpartum days 90 to 150; afterward, the patient returned to normal life without the elastic band device. Use of an elastic band device was associated with a reduction of the pubic width and pain associated after obstetric pubic symphysis separation.

  12. Sport socks do not enhance calf muscle pump function but inelastic wraps do.

    PubMed

    Partsch, H; Mosti, G

    2014-12-01

    Aim of the study was to measure the effect of elastic and inelastic compression on calf muscle pump function in healthy male athletes. This was an experimental study which included 21 healthy male athletes. The ejection fraction (EF) of the venous calf pump was measured comparing the effects of a variety of compression materials: 1) sport compression stockings; 2) light zinc paste bandages; 3) sport compression stockings with additional Velcro® wraps over the calf. The influence of sport stocking and wraps on the venous calibre at the largest calf circumference in the lying and standing position was investigated using MRI. Inelastic compression exerting a median pressure in the standing position of 37.5 mmHg (zinc paste) and 48 mmHg (loosely applied straps over a sport stocking) achieved a significant increase of EF up to 100%. Sport stockings alone with a standing pressure of 19-24 mmHg did not show a significant change of EF. MRI demonstrated some venous narrowing in the lying but not in the standing position. By wrapping inelastic straps over the stocking an emptying of the veins in the lying and a considerable narrowing in the standing position could be observed. Venous calf pump function in athletes is not influenced by elastic sport stockings, but inelastic wraps either alone or applied over sport stockings lead to a significant enhancement.

  13. Heterogeneous neuromuscular activation within human rectus femoris muscle during pedaling.

    PubMed

    Watanabe, Kohei; Kouzaki, Motoki; Moritani, Toshio

    2015-09-01

    We investigated the effect of workload and the use of pedal straps on the spatial distribution of neuromuscular activation within the rectus femoris (RF) muscle during pedaling movements. Eleven healthy men performed submaximal pedaling exercises on an electrically braked ergometer at different workloads and with or without pedal straps. During these tasks, surface electromyograms (SEMGs) were recorded from the RF using 36 electrode pairs, and central locus activation (CLA) was calculated along the longitudinal line of the muscle. CLA moved markedly, indicating changes in spatial distribution of SEMG within the muscle, during a crank cycle under all conditions (P < 0.05). There were significant differences in CLA among different workloads and between those with and without pedal straps (P < 0.05). These results suggest that neuromuscular activation within the RF is regulated regionally by changes in workload and the use of pedal straps during pedaling. © 2014 Wiley Periodicals, Inc.

  14. Inferring bread doneness with air-pulse/ultrasonic ranging measurements of the loaf elastic response

    NASA Astrophysics Data System (ADS)

    Faeth, Loren Elbert

    This research marks the discovery of a method by which bread doneness may be determined based on the elastic properties of the loaf as it bakes. The purpose of the study was to determine if changes in bread characteristics could be determined by non-contact methods during baking, as the basis for improved control of the baking process. Current control of the baking process is based on temperature and dwell time, which are determined by experience to produce a produce which is approximately ``done.'' There is no direct measurement of the property of interest, doneness. An ultrasonic measurement system was developed to measure the response of the loaf to an external stimulus. ``Doneness,'' as reflected in the internal elastic consistency of the bakery product, is assessed in less than 1/2 second, and requires no closer approach to the moving bakery product than about 2 inches. The system is designed to be compatible with strapped bread pans in a standard traveling-tray commercial oven.

  15. Effects of Crossed Brassiere Straps on Pain, Range of Motion, and Electromyographic Activity of Scapular Upward Rotators in Women With Scapular Downward Rotation Syndrome.

    PubMed

    Kang, Min-Hyeok; Choi, Ji-Young; Oh, Jae-seop

    2015-12-01

    Scapular downward rotation syndrome manifests as an abnormally downward-rotated scapula at rest or with arm motion and typically results in neck and shoulder pain. The brassiere strap has been suggested as a possible contributing factor to scapula downward rotation and pain in the upper trapezius because of increased downward rotational force on the lateral aspect of the scapula. No study, however, has examined the influences of a modified brassiere strap on pain in and the function of the scapular muscles. To examine the effects of crossed brassiere straps on the pressure pain threshold (PPT) of the upper trapezius, neck rotation range of motion (ROM), and electromyographic activity of the scapular upward rotators in females with scapular downward rotation syndrome. Cross-over design. Laboratory. In total, 15 female subjects with scapular downward rotation syndrome were recruited at hospitals and a local university. All participants performed neck rotation and humeral elevation under 2 different conditions: parallel and crossed brassiere straps. The PPT of the upper trapezius was measured using an analog algometer, whereas neck rotation ROM was quantified with a 3-dimensional ultrasonic motion analysis system. The electromyographic activities of the upper trapezius, serratus anterior, and lower trapezius during humeral elevation were assessed with a surface electromyography system. Outcome measures were assessed under parallel and crossed brassiere strap conditions, and differences in outcomes between the conditions were analyzed using a paired t-test. The PPT and neck rotation ROM were increased when the subject was wearing the brassiere with crossed versus parallel straps (P < .001). Greater electromyographic activities of the serratus anterior, lower trapezius, and lesser upper trapezius muscles during humeral elevation were found under the crossed strap condition than the parallel strap condition (P < .05). These findings provide useful information for clinicians when designing management programs to decrease pain and improve biomechanical function for females with scapular downward rotation syndrome. Copyright © 2015 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  16. Study and design of the ion cyclotron resonance heating system for the stellarator Wendelstein 7-X

    NASA Astrophysics Data System (ADS)

    Ongena, J.; Messiaen, A.; Van Eester, D.; Schweer, B.; Dumortier, P.; Durodie, F.; Kazakov, Ye. O.; Louche, F.; Vervier, M.; Koch, R.; Krivska, A.; Lyssoivan, A.; Van Schoor, M.; Wauters, T.; Borsuk, V.; Neubauer, O.; Schmitz, O.; Offermans, G.; Altenburg, Y.; Baylard, C.; Birus, D.; Bozhenkov, S.; Hartmann, D. A.; Kallmeyer, J. P.; Renard, S.; Wolf, R. C.; Fülöp, T.

    2014-06-01

    The current status of the mechanical and electromagnetic design for the ICRF antenna system for W7-X is presented. Two antenna plugins are discussed: one consisting of a pair of straps with pre-matching to cover the first frequency band, 25-38 MHz, and a second one consisting of two short strap triplets to cover a frequency band around 76 MHz. This paper focusses on the two strap antenna for the lower frequency band. Power coupling of the antenna to a reference plasma profile is studied with the help of the codes TOPICA and Microwave Studio that deliver the scattering matrix needed for the optimization of the geometric parameters of the straps and antenna box. Radiation power spectra for different phasings of the two straps are obtained using the code ANTITER II and different heating scenario are discussed. The potential for heating, fast particle generation, and current drive is discussed. The problem of RF coupling through the plasma edge and of edge power deposition is summarized. Important elements of the complete ion cyclotron resonance heating system are discussed: a resonator circuit with tap feed to limit the maximum voltage in the system, and a decoupler to counterbalance the large mutual coupling between the 2 straps. The mechanical design highlights the challenges encountered with this antenna: adaptation to a large variety of plasma configurations, the limited space within the port to accommodate the necessary matching components and the watercooling needed for long pulse operation.

  17. A crucial role for the phosphorylation of STRAP at Ser188 by MPK38 in STRAP-dependent cell death through ASK1, TGF-β, p53, and PI3K/PDK1 signaling pathways

    PubMed Central

    Seong, Hyun-A; Manoharan, Ravi; Ha, Hyunjung

    2014-01-01

    Serine-threonine kinase receptor-associated protein (STRAP) is a TGF-β receptor-interacting protein that participates in the regulation of cell proliferation and cell death in response to various stresses. Here, we demonstrate that STRAP phosphorylation plays an important role in determining the pro- or anti-apoptotic function of STRAP. Murine protein serine/threonine kinase 38 (MPK38) phosphorylates STRAP at Ser188 via direct interaction. Complex formation between STRAP and MPK38 is mediated by Cys152 and Cys270 of STRAP and Cys339 and Cys377 of MPK38, suggesting the redox dependency of this interaction. MPK38-mediated STRAP Ser188 phosphorylation contributes to the pro-apoptotic function of STRAP by modulating key steps in STRAP-dependent ASK1, TGF-β, p53, and PI3K/PDK1 signaling pathways. Moreover, knockdown of endogenous MPK38 using an inducible MPK38 shRNA system and in vivo activation of MPK38 by treatment of HEK293 and STRAP-null MEF cells with 1-chloro-2,4-dinitrobenzene (DNCB), a specific inhibitor of Trx reductase, provide evidence that STRAP Ser188 phosphorylation plays a key role in STRAP-dependent cell death. Adenoviral delivery of MPK38 in mice also demonstrates that STRAP Ser188 phosphorylation in the liver is tightly associated with cell death and proliferation through ASK1, TGF-β, p53, and PI3K/PDK1 pathways, resulting in apoptotic cell death. PMID:25485581

  18. A crucial role for the phosphorylation of STRAP at Ser(188) by MPK38 in STRAP-dependent cell death through ASK1, TGF-β, p53, and PI3K/PDK1 signaling pathways.

    PubMed

    Seong, Hyun-A; Manoharan, Ravi; Ha, Hyunjung

    2014-01-01

    Serine-threonine kinase receptor-associated protein (STRAP) is a TGF-β receptor-interacting protein that participates in the regulation of cell proliferation and cell death in response to various stresses. Here, we demonstrate that STRAP phosphorylation plays an important role in determining the pro- or anti-apoptotic function of STRAP. Murine protein serine/threonine kinase 38 (MPK38) phosphorylates STRAP at Ser(188) via direct interaction. Complex formation between STRAP and MPK38 is mediated by Cys(152) and Cys(270) of STRAP and Cys(339) and Cys(377) of MPK38, suggesting the redox dependency of this interaction. MPK38-mediated STRAP Ser(188) phosphorylation contributes to the pro-apoptotic function of STRAP by modulating key steps in STRAP-dependent ASK1, TGF-β, p53, and PI3K/PDK1 signaling pathways. Moreover, knockdown of endogenous MPK38 using an inducible MPK38 shRNA system and in vivo activation of MPK38 by treatment of HEK293 and STRAP-null MEF cells with 1-chloro-2,4-dinitrobenzene (DNCB), a specific inhibitor of Trx reductase, provide evidence that STRAP Ser(188) phosphorylation plays a key role in STRAP-dependent cell death. Adenoviral delivery of MPK38 in mice also demonstrates that STRAP Ser(188) phosphorylation in the liver is tightly associated with cell death and proliferation through ASK1, TGF-β, p53, and PI3K/PDK1 pathways, resulting in apoptotic cell death.

  19. Umbilical hernia: Influence of adhesive strapping on outcome.

    PubMed

    Hayashida, Makoto; Shimozono, Takashi; Meiri, Satoru; Kurogi, Jun; Yamashita, Naoto; Ifuku, Toshinobu; Yamamura, Yoshiko; Tanaka, Etsuko; Ishii, Shigeki; Shimonodan, Hidemi; Mihara, Yuka; Kono, Keiichiro; Nakatani, Keigo; Nishiguchi, Toshihiro

    2017-12-01

    Adhesive strapping for umbilical hernia has been re-evaluated as a promising treatment. We evaluated the influence of adhesive strapping on the outcome of umbilical hernia. We retrospectively evaluated patients with umbilical hernia referred to the present institution from April 2011 to December 2015. Patients who were treated with adhesive strapping were compared with an observation alone group. The adhesive strapping group was also subdivided into two groups: the cure group and the treatment failure group. A total of 212 patients with umbilical hernia were referred to the present institution. Eighty-nine patients were treated with adhesive strapping, while 27 had observation only. The cure rate in the adhesive strapping group was significantly higher than that in the observation group. The duration of treatment of the adhesive strapping group was significantly shorter than that of the observation group. In the adhesive strapping group, the patients in the cure group were treated significantly earlier than those in the treatment failure group (P < 0.001). Furthermore, even in cases of umbilical hernia non-closure, surgical repair was easier after adhesive strapping. Adhesive strapping represents a promising treatment for umbilical hernia. To achieve the best results, adhesive strapping should be initiated as early as possible. © 2017 Japan Pediatric Society.

  20. 78 FR 9309 - Airworthiness Directives; MD Helicopters, Inc., Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-08

    ... date, creating a component record card for each T-T strap, and revising the airworthiness limitations..., marking each T-T strap with the expiration date, creating a component record card for each T-T strap, and... date; creating a component record card for each affected T-T strap; replacing T-T straps that have been...

  1. A Newly Designed Tennis Elbow Orthosis With a Traditional Tennis Elbow Strap in Patients With Lateral Epicondylitis

    PubMed Central

    Saremi, Hossein; Chamani, Vahid; Vahab-Kashani, Reza

    2016-01-01

    Background Lateral epicondylitis is a common cause of pain and upper limb dysfunction. The use of counterforce straps for treatment of lateral epicondylitis is widespread. This kind of orthosis can be modified to have a greater effect on relieving pain by reducing tension on the origin of the extensor pronator muscles. Objectives To determine the immediate effects of a newly designed orthosis on pain and grip strength in patients with lateral epicondylitis. Materials and Methods Twelve participants (six men and six women) were recruited (mean age = 41 ± 6.7 years) and evaluated for pain and grip strength in three sessions. A 48-hour break was taken between each session. The first session was without any orthosis, the second session was with the new modified tennis elbow orthosis, and the third session was with a conventional tennis elbow strap. Results Both counterforce straps were effective. However, significantly more improvement was observed in pain and grip strength after using the newly modified orthosis (P < 0.05). Conclusions The newly designed strap reduces pain more effectively and improves grip strength by causing greater localized pressure on two regions with different force applications (two component vectors versus one). PMID:28180116

  2. KISS for STRAP: user extensions for a protein alignment editor.

    PubMed

    Gille, Christoph; Lorenzen, Stephan; Michalsky, Elke; Frömmel, Cornelius

    2003-12-12

    The Structural Alignment Program STRAP is a comfortable comprehensive editor and analyzing tool for protein alignments. A wide range of functions related to protein sequences and protein structures are accessible with an intuitive graphical interface. Recent features include mapping of mutations and polymorphisms onto structures and production of high quality figures for publication. Here we address the general problem of multi-purpose program packages to keep up with the rapid development of bioinformatical methods and the demand for specific program functions. STRAP was remade implementing a novel design which aims at Keeping Interfaces in STRAP Simple (KISS). KISS renders STRAP extendable to bio-scientists as well as to bio-informaticians. Scientists with basic computer skills are capable of implementing statistical methods or embedding existing bioinformatical tools in STRAP themselves. For bio-informaticians STRAP may serve as an environment for rapid prototyping and testing of complex algorithms such as automatic alignment algorithms or phylogenetic methods. Further, STRAP can be applied as an interactive web applet to present data related to a particular protein family and as a teaching tool. JAVA-1.4 or higher. http://www.charite.de/bioinf/strap/

  3. Negative Rotation Cinch Strap.

    DTIC Science & Technology

    This project discloses an improved unitary parachute torso harness, having a single fastening means, wherein an auxillary tightening strap is...attached to the groin straps of said harness. Said auxillary straps are used to prevent torso rotation or harness slippage and to prevent harness elongation

  4. Identification of a subunit of NADH-dehydrogenase as a p49/STRAP-binding protein.

    PubMed

    Zhang, Xiaomin; Azhar, Gohar; Helms, Scott; Zhong, Ying; Wei, Jeanne Y

    2008-01-29

    The p49/STRAP (or SRFBP1) protein was recently identified in our laboratory as a cofactor of serum response factor that contributes to the regulation of SRF target genes in the heart. In the present study, we report that NDUFAB1, a nuclear encoded subunit of NADH dehydrogenase, represented the majority of the cDNA clones that interacted with p49/STRAP in multiple screenings using the yeast two-hybrid system. The p49/STRAP and NDUFAB1 proteins interacted and co-localized with each other in the cell. The p49/STRAP protein contains four classic nuclear localization sequence motifs, and it was observed to be present predominantly in the nucleus. Overexpression of p49/STRAP altered the intracellular level of NAD, and reduced the NAD/NADH ratio. Overexpression of p49/STRAP also induced the deacetylation of serum response factor. These data suggest that p49/STRAP plays a role in the regulation of intracellular processes such as cardiac cellular metabolism, gene expression, and possibly aging.

  5. Effect of backpack shoulder straps length on cervical posture and upper trapezius pressure pain threshold

    PubMed Central

    Abdelraouf, Osama Ragaa; Hamada, Hamada Ahmed; Selim, Ali; Shendy, Wael; Zakaria, Hoda

    2016-01-01

    [Purpose] This study was performed to investigate the effect of the length of backpack shoulder straps on upper trapezius muscle pain threshold and craniovertebral angle. [Subjects and Methods] There were 25 participants, with ages from 15 to 23 years old. Upper trapezius pain threshold and craniovertebral angle were measured for all subjects without the backpack then re-measured after walking on a treadmill for 15 min under 2 conditions: 1) wearing a backpack with short straps; and 2) wearing a backpack with long straps. [Results] there was a significant reduction in upper trapezius pain threshold and craniovertebral angle while carrying a backpack with long shoulder straps, compared to use of a backpack with short shoulder straps or no backpack. [Conclusion] A backpack with short straps is less harmful than a backpack with long straps. This result should be considered in ergonomic design of backpacks to reduce the incidence of various physiological and biomechanical disorders. PMID:27799665

  6. Turbine blade vibration dampening

    DOEpatents

    Cornelius, C.C.; Pytanowski, G.P.; Vendituoli, J.S.

    1997-07-08

    The present turbine wheel assembly increases component life and turbine engine longevity. The combination of the strap and the opening combined with the preestablished area of the outer surface of the opening and the preestablished area of the outer circumferential surface of the strap and the friction between the strap and the opening increases the life and longevity of the turbine wheel assembly. Furthermore, the mass ``M`` or combined mass ``CM`` of the strap or straps and the centrifugal force assist in controlling vibrations and damping characteristics. 5 figs.

  7. Turbine blade vibration dampening

    DOEpatents

    Cornelius, Charles C.; Pytanowski, Gregory P.; Vendituoli, Jonathan S.

    1997-07-08

    The present turbine wheel assembly increases component life and turbine engine longevity. The combination of the strap and the opening combined with the preestablished area of the outer surface of the opening and the preestablished area of the outer circumferential surface of the strap and the friction between the strap and the opening increases the life and longevity of the turbine wheel assembly. Furthermore, the mass "M" or combined mass "CM" of the strap or straps and the centrifugal force assist in controlling vibrations and damping characteristics.

  8. Scattering from thin dielectric straps surrounding a perfectly conducting structure

    NASA Technical Reports Server (NTRS)

    Al-Hekail, Zeyad; Gupta, Inder J.

    1989-01-01

    A method to calculate the electromagnetic scattered fields from a dielectric strap wrapped around convex, conducting structure is presented. A moment method technique is used to find the current excited within the strap by the incident plane wave. Then, Uniform Geometrical Theory of Diffraction (UTD) is used to compute the fields scattered by the strap. Reasonable agreement was obtained between the computed and the measured results. The results found in this study are useful in evaluating straps as a target support structure for scattering measurements.

  9. Thermal conductance characterization of a pressed copper rope strap between 0.13 K and 10 K

    DOE PAGES

    Dhuley, R. C.; Ruschman, M.; Link, J. T.; ...

    2017-07-05

    Mechanically pressing the ends of a copper braid in solid copper is an effective way of constructing solderless conductive straps for cryogenic applications. In this paper we present thermal conductance data of such a copper strap measured using the two-heater one-thermometer method. The measurements span a wide temperature range of 0.13–10 K applicable to a variety of cryogenic systems employing liquid helium, pulse tube coolers, adiabatic demagnetization refrigerators, and others. Above ≈1.5 K, the braid thermal conductivity dominates the strap conductance resulting in a near-linear dependence with temperature. The variation with temperature below ≈1.5 K is near-quadratic indicating dominance ofmore » the pressed contact conductance at the strap ends. In conclusion, electron-beam welding the braid to the strap ends is shown to be a promising solution for improving sub-Kelvin thermal conductance of the strap.« less

  10. Thermal conductance characterization of a pressed copper rope strap between 0.13 K and 10 K

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dhuley, R. C.; Ruschman, M.; Link, J. T.

    Mechanically pressing the ends of a copper braid in solid copper is an effective way of constructing solderless conductive straps for cryogenic applications. In this paper we present thermal conductance data of such a copper strap measured using the two-heater one-thermometer method. The measurements span a wide temperature range of 0.13–10 K applicable to a variety of cryogenic systems employing liquid helium, pulse tube coolers, adiabatic demagnetization refrigerators, and others. Above ≈1.5 K, the braid thermal conductivity dominates the strap conductance resulting in a near-linear dependence with temperature. The variation with temperature below ≈1.5 K is near-quadratic indicating dominance ofmore » the pressed contact conductance at the strap ends. In conclusion, electron-beam welding the braid to the strap ends is shown to be a promising solution for improving sub-Kelvin thermal conductance of the strap.« less

  11. 78 FR 27020 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-09

    ... circumferential tear strap, the ``Z'' stiffeners at the dome cap, and existing repairs [retained actions from AD... Inspection Under the Tear Strap This paragraph restates the one-time inspection under the tear strap required... under the outer circumferential tear strap, or do a one-time HFEC inspection for cracks from the forward...

  12. Identification of a subunit of NADH-dehydrogenase as a p49/STRAP-binding protein

    PubMed Central

    Zhang, Xiaomin; Azhar, Gohar; Helms, Scott; Zhong, Ying; Wei, Jeanne Y

    2008-01-01

    Background The p49/STRAP (or SRFBP1) protein was recently identified in our laboratory as a cofactor of serum response factor that contributes to the regulation of SRF target genes in the heart. Results In the present study, we report that NDUFAB1, a nuclear encoded subunit of NADH dehydrogenase, represented the majority of the cDNA clones that interacted with p49/STRAP in multiple screenings using the yeast two-hybrid system. The p49/STRAP and NDUFAB1 proteins interacted and co-localized with each other in the cell. The p49/STRAP protein contains four classic nuclear localization sequence motifs, and it was observed to be present predominantly in the nucleus. Overexpression of p49/STRAP altered the intracellular level of NAD, and reduced the NAD/NADH ratio. Overexpression of p49/STRAP also induced the deacetylation of serum response factor. Conclusion These data suggest that p49/STRAP plays a role in the regulation of intracellular processes such as cardiac cellular metabolism, gene expression, and possibly aging. PMID:18230186

  13. ICRH antenna S-matrix measurements and plasma coupling characterisation at JET

    NASA Astrophysics Data System (ADS)

    Monakhov, I.; Jacquet, P.; Blackman, T.; Bobkov, V.; Dumortier, P.; Helou, W.; Lerche, E.; Kirov, K.; Milanesio, D.; Maggiora, R.; Noble, C.; Contributors, JET

    2018-04-01

    The paper is dedicated to the characterisation of multi-strap ICRH antenna coupling to plasma. Relevance of traditional concept of coupling resistance to antennas with mutually coupled straps is revised and the importance of antenna port excitation consistency for application of the concept is highlighted. A method of antenna S-matrix measurement in presence of plasma is discussed allowing deeper insight into the problem of antenna-plasma coupling. The method is based entirely on the RF plant hardware and control facilities available at JET and it involves application of variable phasing between the antenna straps during the RF plant operations at  >100 kW. Unlike traditional techniques relying on low-power (~10 mW) network analysers, the applied antenna voltage amplitudes are relevant to practical conditions of ICRH operations; crucially, they are high enough to minimise possible effects of antenna loading non-linearity due to the RF sheath effects and other phenomena which could affect low-power measurements. The method has been successfully applied at JET to conventional 4-port ICRH antennas energised at frequencies of 33 MHz, 42 MHz and 51 MHz during L-mode plasma discharges while different gas injection modules (GIMs) were used to maintain comparable plasma densities during the pulses. The S-matrix assessment and its subsequent processing yielding ‘global’ antenna coupling resistances in conditions of equalised port maximum voltages allowed consistent description of antenna coupling to plasma at different strap phasing, operational frequencies and applied GIMs. Comprehensive experimental characterisation of mutually coupled antenna straps in presence of plasma also provided a unique opportunity for in-depth verification of TOPICA computer simulations.

  14. Reappraisal of adhesive strapping as treatment for infantile umbilical hernia.

    PubMed

    Yanagisawa, Satohiko; Kato, Mototoshi; Oshio, Takehito; Morikawa, Yasuhide

    2016-05-01

    Most umbilical hernias spontaneously close by 3-5 years of age; therefore, surgical repair is considered only in children whose hernias have not closed by this point. At present, adhesive strapping is not the preferred treatment for umbilical hernias because of the lack of supporting evidence regarding its efficacy, and its association with skin complications. This aim of this study was to examine umbilical hernia closure on ultrasonography, and reassess the merits of adhesive strapping. Between January 2013 and December 2014, 89 infants underwent adhesive strapping for umbilical hernia. The strapping was changed once a week. The diameter of the hernia orifice was measured on ultrasonography every 2 weeks until closure. The closure speed (CS) of the hernia orifice was compared between the infants treated with adhesive strapping and those undergoing observation alone. The association between CS and birthweight, gestational age, diameter of the hernia orifice, and timing of treatment (before 12 weeks of age vs between 12 and 26 weeks of age) was also analyzed. Closure was achieved after 2-13 weeks of strapping in 81 infants (91%), and the likelihood of closure was not affected by the diameter of the hernia orifice, gestational age, or the timing of treatment. The mean CS of the infants treated with adhesive strapping was significantly faster than that of the infants undergoing observation alone (2.59 vs 0.37 mm/week, P < 0.05). Adhesive strapping was discontinued in five of the 89 infants (5.6%) due to severe skin complications. Adhesive strapping promoted early spontaneous umbilical hernia closure compared with observation alone, regardless of the diameter of the hernia orifice. Adhesive strapping is an effective alternative to surgery and observation. © 2015 Japan Pediatric Society.

  15. 21 CFR 868.5560 - Gas mask head strap.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas mask head strap. 868.5560 Section 868.5560...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5560 Gas mask head strap. (a) Identification. A gas mask head strap is a device used to hold an anesthetic gas mask in position on a patient's...

  16. 77 FR 66757 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-07

    ... tear straps and in the skin locations common to the tear straps. Additionally, we received a report of... cracking in the lap joint fastener row between tear straps of the crown lap and do a detailed inspection of...-53A1255, Revision 2, dated August 7, 2012. (j) Optional Inspections for Tear Strap Locations Only As an...

  17. 77 FR 42459 - Airworthiness Directives; MD Helicopters, Inc. (MDHI) Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-19

    ... the retirement life of certain T-T straps, marking each T-T strap with the expiration date, creating a... strap with an expiration date; creating a component record card for each affected T-T strap; replacing T...-101, P/N 900R3442009-103, or P/N 900R6442009-103 (installed on MDHI Model MD900 helicopters); Creating...

  18. Heterobimetallic porphyrin complexes displaying triple dynamics: coupled metal motions controlled by constitutional evolution.

    PubMed

    Le Gac, Stéphane; Fusaro, Luca; Roisnel, Thierry; Boitrel, Bernard

    2014-05-07

    A bis-strap porphyrin ligand (1), with an overhanging carboxylic acid group on each side of the macrocycle, has been investigated toward the formation of dynamic libraries of bimetallic complexes with Hg(II), Cd(II), and Pb(II). Highly heteroselective metalation processes occurred in the presence of Pb(II), with Hg(II) or Cd(II) bound out-of-plane to the N-core and "PbOAc" bound to a carboxylate group of a strap on the opposite side. The resulting complexes, 1(Hg)·PbOAc and 1(Cd)·PbOAc, display three levels of dynamics. The first is strap-level (interactional dynamics), where the PbOAc moiety swings between the left and right side of the strap owing to a second sphere of coordination with lateral amide functions. The second is ligand-level (motional dynamics), where 1(Hg)·PbOAc and 1(Cd)·PbOAc exist as two degenerate states in equilibrium controlled by a chemical effector (AcO(-)). The process corresponds to a double translocation of the metal ions according to an intramolecular migration of Hg(II) or Cd(II) through the N-core, oscillating between the two equivalent overhanging carbonyl groups, coupled to an intermolecular pathway for PbOAc exchanging between the two equivalent overhanging carboxylate groups (N-core(up) ⇆ N-core(down) coupled to strap(down) ⇆ strap(up), i.e., coupled motion #1 in the abstract graphic). The third is library-level (constitutional dynamics), where a dynamic constitutional evolution of the system was achieved by the successive addition of two chemical effectors (DMAP and then AcO(-)). It allowed shifting equilibrium forward and backward between 1(Hg)·PbOAc and the corresponding homobimetallic complexes 1(Hg2)·DMAP and 1(Pb)·PbOAc. The latter displays a different ligand-level dynamics, in the form of an intraligand coupled migration of the Pb(II) ions (N-core(up) ⇆ strap(up) coupled to strap(down) ⇆ N-core(down), i.e., coupled motion #2 in the abstract graphic). In addition, the neutral "bridged" complexes 1HgPb and 1CdPb, with the metal ions on opposite sides both bound to the N-core and to a carboxylate of a strap, were structurally characterized. These results establish an unprecedented approach in supramolecular coordination chemistry, by considering the reversible interaction of a metal ion with the porphyrin N-core as a new source of self-organization processes. This work should provide new inspirations for the design of innovative adaptative materials and devices.

  19. The immediate effect of patellar tendon strap on weight-bearing asymmetry during squatting in patients with unilateral knee osteoarthritis: A pilot study.

    PubMed

    Demirbüken, İlkşan; Özyürek, Seher; Angın, Salih

    2016-12-01

    Knee osteoarthritis has commonly been associated with a symptom of pain resulting in an inter-limb weight-bearing asymmetry during functional tasks. Patellar tendon strap is one of the non-pharmacologic interventions to alleviate knee pain. To investigate the immediate effect of a patellar tendon strap on weight-bearing asymmetry during squatting in people with unilateral knee osteoarthritis. Cross-sectional study. Ten patients with unilateral knee osteoarthritis and 10 healthy subjects were included in the study. Weight-bearing asymmetry of patients was assessed using a weight-bearing squat test during squatting at 30° and 60° both with and without patellar tendon strap. Pain intensity was assessed during squatting in unstrapped and strapped conditions with Visual Analog Scale. The decrease in weight-bearing asymmetry values immediately after wearing patellar tendon strap during 30° (p = 0.006) and 60° (p = 0.011) of squatting tests was significantly higher in knee osteoarthritis patients than in healthy subjects. Reported pain intensity was similar in unstrapped and strapped conditions (p = 0.066). The results of this study showed improved inter-limb weight-bearing symmetry during squatting. Further research with larger sample sizes investigating the effect of patellar tendon strap on weight-bearing asymmetry during functional activities in people with knee osteoarthritis is warranted. Patellar tendon straps (easily fit and cheap unlike knee braces) had more improvements in inter-limb weight-bearing symmetry during squatting in people with knee osteoarthritis compared to healthy subjects. This study is a new insight for future studies to investigate clinical benefits of wearing patellar tendon straps in this population. © The International Society for Prosthetics and Orthotics 2015.

  20. Tourniquet pressures: strap width and tensioning system widths.

    PubMed

    Wall, Piper L; Coughlin, Ohmar; Rometti, Mary; Birkholz, Sarah; Gildemaster, Yvonne; Grulke, Lisa; Sahr, Sheryl; Buising, Charisse M

    2014-01-01

    Pressure distribution over tourniquet width is a determinant of pressure needed for arterial occlusion. Different width tensioning systems could result in arterial occlusion pressure differences among nonelastic strap designs of equal width. Ratcheting Medical Tourniquets (RMTs; m2 inc., http://www.ratcheting buckles.com) with a 1.9 cm-wide (Tactical RMT) or 2.3 cm-wide (Mass Casualty RMT) ladder were directly compared (16 recipients, 16 thighs and 16 upper arms for each tourniquetx2). Then, RMTs were retrospectively compared with the windlass Combat Application Tourniquet (C-A-T ["CAT"], http://combattourniquet.com) with a 2.5 cm-wide internal tensioning strap. Pressure was measured with an air-filled No. 1 neonatal blood pressure cuff under each 3.8 cm-wide tourniquet. RMT circumferential pressure distribution was not uniform. Tactical RMT pressures were not higher, and there were no differences between the RMTs in the effectiveness, ease of use ("97% easy"), or discomfort. However, a difference did occur regarding tooth skipping of the pawl during ratchet advancement: it occurred in 1 of 64 Tactical RMT applications versus 27 of 64 Mass Casualty RMT applications. CAT and RMT occlusion pressures were frequently over 300 mmHg. RMT arm occlusion pressures (175-397 mmHg), however, were lower than RMT thigh occlusion pressures (197-562 mmHg). RMT effectiveness was better with 99% reached occlusion and 1% lost occlusion over 1 minute versus the CAT with 95% reached occlusion and 28% lost occlusion over 1 minute. RMT muscle tension changes (up to 232 mmHg) and pressure losses over 1 minute (24±11 mmHg arm under strap to 40±12 mmHg thigh under ladder) suggest more occlusion losses may have occurred if tourniquet duration was extended. The narrower tensioning system Tactical RMT has better performance characteristics than the Mass Casualty RMT. The 3.8 cm-wide RMTs have some pressure and effectiveness similarities and differences compared with the CAT. Clinically significant pressure changes occur under nonelastic strap tourniquets with muscle tension changes and over time periods as short as 1 minute. An examination of pressure and occlusion changes beyond 1 minute would be of interest. 2014.

  1. Electromyographic activity of strap and cricothyroid muscles in pitch change.

    PubMed

    Roubeau, B; Chevrie-Muller, C; Lacau Saint Guily, J

    1997-05-01

    The EMG activity of the cricothyroid muscle (CT) and the three extrinsic laryngeal muscles (thyohyoid, TH; sternothyroid, ST, and sternohyoid, SH) were recorded throughout the voice range of one female and one male subject, both untrained singers. The voice range was examined using rising and falling glissandos (production of a sustained sound with progressive and continuous variation of fundamental frequency). Muscle activity was observed at various pitches during the glissandos. The strap muscle activity during the production of glissandos appears to be synergistic. At the lowest frequency, the CT is inactive but strap muscles (TH, ST, SH) are active. As frequency increases, strap muscle activity decreases while the CT controls frequency in the middle of the range. At higher frequencies the strap muscles once again become active. This activity might depend on the vocal vibratory mechanism involved. The role of the strap muscles at high pitches is a widely debated point but it seems that in some way they control the phenomena relevant to the rising pitch. The phasic-type strap muscle activity contrasts with the tonic-type activity of the CT. The CT closely controls the frequency, while the straps are not directly linked to the pitch but rather to the evolution of the frequency of voice production (speaking voice, singing voice, held notes, glissandos, trillo, vibrato, etc.).

  2. C-STrap Sample Preparation Method--In-Situ Cysteinyl Peptide Capture for Bottom-Up Proteomics Analysis in the STrap Format.

    PubMed

    Zougman, Alexandre; Banks, Rosamonde E

    2015-01-01

    Recently we introduced the concept of Suspension Trapping (STrap) for bottom-up proteomics sample processing that is based upon SDS-mediated protein extraction, swift detergent removal and rapid reactor-type protein digestion in a quartz depth filter trap. As the depth filter surface is made of silica, it is readily modifiable with various functional groups using the silane coupling chemistries. Thus, during the digest, peptides possessing specific features could be targeted for enrichment by the functionalized depth filter material while non-targeted peptides could be collected as an unbound distinct fraction after the digest. In the example presented here the quartz depth filter surface is functionalized with the pyridyldithiol group therefore enabling reversible in-situ capture of the cysteine-containing peptides generated during the STrap-based digest. The described C-STrap method retains all advantages of the original STrap methodology and provides robust foundation for the conception of the targeted in-situ peptide fractionation in the STrap format for bottom-up proteomics. The presented data support the method's use in qualitative and semi-quantitative proteomics experiments.

  3. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kung, C C; Brunkhorst, C; Greenough, N

    Experimental results have shown that the high harmonic fast wave (HHFW) at 30 MHz can provide substantial plasma heating and current drive for the NSTX spherical tokamak operation. However, the present antenna strap design rarely achieves the design goal of delivering the full transmitter capability of 6 MW to the plasma. In order to deliver more power to the plasma, a new antenna strap design and the associated coaxial line feeds are being constructed. This new antenna strap design features two feedthroughs to replace the old single feed-through design. In the design process, CST Microwave Studio has been used tomore » simulate the entire new antenna strap structure including the enclosure and the Faraday shield. In this paper, the antenna strap model and the simulation results will be discussed in detail. The test results from the new antenna straps with their associated resonant loops will be presented as well.« less

  4. Surge current and electron swarm tunnel tests of thermal blanket and ground strap materials

    NASA Technical Reports Server (NTRS)

    Hoffmaster, D. K.; Inouye, G. T.; Sellen, J. M., Jr.

    1977-01-01

    The results are described of a series of current conduction tests with a thermal control blanket to which grounding straps have been attached. The material and the ground strap attachment procedure are described. The current conduction tests consisted of a surge current examination of the ground strap and a dilute flow, energetic electron deposition and transport through the bulk of the insulating film of this thermal blanket material. Both of these test procedures were used previously with thermal control blanket materials.

  5. Thermal Strap And Cushion For Thermoelectric Cooler

    NASA Technical Reports Server (NTRS)

    Jones, Jack A.; Petrick, S. Walter; Bard, Steven

    1991-01-01

    Inexpensive cushioning strap proposed for use as thermal contact between thermoelectric cooler and device to be cooled, such as laser diode, infrared detector, or charge-coupled device for imaging. Provides high thermal conductance while minimizing thermal and mechanical stresses on thermoelectric cooler. Used as alternative to flexible thermal strap made of silver.

  6. 77 FR 57990 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-19

    ...'' chord of the bulkhead, the web located under the outer circumferential tear strap, the ``Z'' stiffeners..., dated December 16, 2011. (m) New Requirements: One-Time Inspection Under the Tear Strap Except as... the outer circumferential tear strap, or do a one-time HFEC inspection for cracks from the forward...

  7. EFFECTIVENESS OF NYLON DRAG STRAPS FOR BRAKING MONORAIL SLEDS.

    DTIC Science & Technology

    Velocity versus coast distance measurements on two monorail rocket sleds were conducted on the Holloman track to obtain numerical information on the...sleds and the drag straps. The straps as described are shown to increase the effective drag area of the monorail sleds used by approximately one square

  8. 49 CFR 393.104 - What standards must cargo securement devices and systems meet in order to satisfy the...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... working load limit. (c) Vehicle structures and anchor points. Vehicle structures, floors, walls, decks... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1 2 Standard Specification for Strapping, Flat Steel and...

  9. 49 CFR 393.104 - What standards must cargo securement devices and systems meet in order to satisfy the...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... working load limit. (c) Vehicle structures and anchor points. Vehicle structures, floors, walls, decks... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1,2 Standard Specification for Strapping, Flat Steel and...

  10. 49 CFR 393.104 - What standards must cargo securement devices and systems meet in order to satisfy the...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... working load limit. (c) Vehicle structures and anchor points. Vehicle structures, floors, walls, decks... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1 2 Standard Specification for Strapping, Flat Steel and...

  11. Automated Design of Restraint Layer of an Inflatable Vessel

    NASA Technical Reports Server (NTRS)

    Spexarth, Gary

    2007-01-01

    A Mathcad computer program largely automates the design and analysis of the restraint layer (the primary load-bearing layer) of an inflatable vessel that consists of one or more sections having cylindrical, toroidal, and/or spherical shape(s). A restraint layer typically comprises webbing in the form of multiple straps. The design task includes choosing indexing locations along the straps, computing the load at every location in each strap, computing the resulting stretch at each location, and computing the amount of undersizing required of each strap so that, once the vessel is inflated and the straps thus stretched, the vessel can be expected to assume the desired shape. Prior to the development of this program, the design task was performed by use of a difficult-to-use spreadsheet program that required manual addition of rows and columns depending on the numbers of strap rows and columns of a given design. In contrast, this program is completely parametric and includes logic that automatically adds or deletes rows and columns as needed. With minimal input from the user, this program automatically computes indexing locations, strap lengths, undersizing requirements, and all design data required to produce detailed drawings and assembly procedures. It also generates textual comments that help the user understand the calculations.

  12. A 2-year follow-up of a study to compare the efficacy of lateral wedged insoles with subtalar strapping and in-shoe lateral wedged insoles in patients with varus deformity osteoarthritis of the knee.

    PubMed

    Toda, Y; Tsukimura, N

    2006-03-01

    This study was conducted in order to assess the effect of wearing a lateral wedged insole with a subtalar strap for 2 years in patients with osteoarthritis varus deformity of the knee (knee OA). The setting was an outpatient clinic. The efficacies of the strapped insole and a traditional shoe insert wedged insole (the inserted insole), as a positive control, were compared at the baseline and after 2 years of treatment. Randomization was performed according to birth date. The 61 female outpatients with knee OA who completed a prior 6-month study were asked to wear their respective insoles continuously as treatment during the course of the 2-year study. The femorotibial angle (FTA) was assessed by standing radiographs obtained while the subjects were barefoot and the Lequesne index of the knee OA at 2 years was compared with those at baseline in each insole group. There were 61 patients in the original study, but 13 patients (21.3%) did not want to wear the insole continuously and five (8.2%) withdrew for other reasons. The 42 patients who completed the 2-year study were evaluated. At the 2-year assessment, participants wearing the subtalar strapped insole (n=21) demonstrated significantly decreased FTA (P=0.015), and significantly improved Lequesne index (P=0.031) in comparison with their baseline assessments. These significant differences were not found in the group with the traditional shoe inserted wedged insole (n=21). Only those participants using the subtalar strapped insole demonstrated significant change in the FTA in comparison with the baseline assessments. If the insole with a subtalar strap maintains FTA for more than 2 years, it may restrict the progression of degenerative articular cartilage lesions of knee OA.

  13. Effect of patellar strap and sports tape on pain in patellar tendinopathy: A randomized controlled trial.

    PubMed

    de Vries, A; Zwerver, J; Diercks, R; Tak, I; van Berkel, S; van Cingel, R; van der Worp, H; van den Akker-Scheek, I

    2016-10-01

    Numerous athletes with patellar tendinopathy (PT) use a patellar strap or sports tape during sports. This study's aim was to investigate the short-term effect of these orthoses on patellar tendon pain. Participants performed the single-leg decline squat, vertical jump test, and triple-hop test under four different conditions (patellar strap, sports tape, placebo, and control). Subsequently, participants practiced sports as usual for 2 weeks; during 1 week, they were assigned to one of the four conditions. Pain was measured with the visual analog scale (VAS). In total, 97 athletes with PT [61% male, age 27.0 (SD8.1), VISA-P 58.5 (SD12.7)] were analyzed. On the single-leg decline squat, the VAS pain score reduced significantly in the patellar strap (14 mm, P = 0.04) and the sports tape condition (13 mm, P = 0.04), compared with control, but not placebo. A significant decrease in VAS pain during sports was found in the sports tape (7 mm, P = 0.04) and placebo group (6 mm, P = 0.04). The VAS pain score two hours after sports decreased significantly in the patellar strap, sports tape and placebo group (8-mm, P < 0.001, 10 mm, P = 0.001 and 7 mm, P = 0.03, respectively). This study's findings indicate that an orthosis (including placebo tape) during sports can reduce pain in PT patients in the short term. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. 49 CFR 393.104 - What standards must cargo securement devices and systems meet in order to satisfy the...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1,2 Standard Specification for Strapping, Flat Steel and... Association of Chain Manufacturers' Welded Steel Chain Specifications, dated September 28, 2005. 4 (3) Webbing...

  15. 49 CFR 393.104 - What standards must cargo securement devices and systems meet in order to satisfy the...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... tiedown assemblies. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing... . . . Must conform to . . . (1) Steel strapping 1,2 Standard Specification for Strapping, Flat Steel and... Association of Chain Manufacturers' Welded Steel Chain Specifications, dated September 28, 2005. 4 (3) Webbing...

  16. 78 FR 1772 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-09

    ...'' chord of the bulkhead, inspection cycle. the web located under the outer circumferential tear strap, the..., 2011. (m) Retained One-Time Inspection Under the Tear Strap This paragraph restates the one-time inspection under the tear strap required by paragraph (m) of AD 2012-18-13, Amendment 39-17190 (77 FR 57990...

  17. 77 FR 38547 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-28

    ... tear strap, in the web near the dome cap, and in the ``Z'' stiffeners near the dome cap. Cracks have... of the web located under the outer circumferential tear strap, or a one-time HFEC inspection to... tear strap. A detailed inspection from the aft side of the bulkhead for oil-canning, and related...

  18. System and method of designing a load bearing layer of an inflatable vessel

    NASA Technical Reports Server (NTRS)

    Spexarth, Gary R. (Inventor)

    2007-01-01

    A computer-implemented method is provided for designing a restraint layer of an inflatable vessel. The restraint layer is inflatable from an initial uninflated configuration to an inflated configuration and is constructed from a plurality of interfacing longitudinal straps and hoop straps. The method involves providing computer processing means (e.g., to receive user inputs, perform calculations, and output results) and utilizing this computer processing means to implement a plurality of subsequent design steps. The computer processing means is utilized to input the load requirements of the inflated restraint layer and to specify an inflated configuration of the restraint layer. This includes specifying a desired design gap between pairs of adjacent longitudinal or hoop straps, whereby the adjacent straps interface with a plurality of transversely extending hoop or longitudinal straps at a plurality of intersections. Furthermore, an initial uninflated configuration of the restraint layer that is inflatable to achieve the specified inflated configuration is determined. This includes calculating a manufacturing gap between pairs of adjacent longitudinal or hoop straps that correspond to the specified desired gap in the inflated configuration of the restraint layer.

  19. 76 FR 59590 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-27

    ... web lap and tear strap splices of the aft pressure bulkhead at STA 1582 due to fatigue. We are... radial web lap and tear strap splices of the aft pressure bulkhead at station (STA) 1582 due to fatigue... prompted by reports of multiple site damage cracks in the radial web lap and tear strap splices of the aft...

  20. 24 CFR 3285.402 - Ground anchor installations.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... least equivalent to that provided by a coating of zinc on steel of not less than 0.30 oz./ft.2 of... recognized testing protocol. (2) Tie-down straps. A 11/4 inch x 0.035 inch or larger steel strapping conforming to ASTM D 3953—97, Standard Specification for Strapping, Flat Steel and Seals (incorporated by...

  1. Explosive Spot Joining of Metals

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J. (Inventor); Perry, Ronnie B. (Inventor)

    1997-01-01

    The invention is an apparatus and method for wire splicing using an explosive joining process. The apparatus consists of a prebend, U-shaped strap of metal that slides over prepositioned wires. A standoff means separates the wires from the strap before joining. An adhesive means holds two ribbon explosives in position centered over the U-shaped strap. A detonating means connects to the ribbon explosives. The process involves spreading strands of each wire to be joined into a flat plane. The process then requires alternating each strand in alignment to form a mesh-like arrangement with an overlapped area. The strap slides over the strands of the wires. and the standoff means is positioned between the two surfaces. The detonating means then initiates the ribbon explosives that drive the strap to accomplish a high velocity. angular collision between the mating surfaces. This collision creates surface melts and collision bonding resulting in electron-sharing linkups.

  2. Permanent wire splicing by an explosive joining process

    NASA Technical Reports Server (NTRS)

    Bement, Laurence J. (Inventor); Kushnick, Anne C. (Inventor)

    1991-01-01

    The invention is an apparatus and method for wire splicing using an explosive joining process. The apparatus consists of a prebent, U-shaped strap of metal that slides over prepositioned wires. A standoff means separates the wires from the strap before joining. An adhesive means holds two ribbon explosives in position centered over the U-shaped strap. A detonating means connects to the ribbon explosives. The process involves spreading strands of each wire to be joined into a flat plane. The process then requires alternating each strand in alignment to form a mesh-like arrangement with an overlapped area. The strap slides over the strands of the wires, and the standoff means is positioned between the two surfaces. The detonating means then initiates the ribbon explosives that drive the strap to accomplish a high velocity, angular collision between the mating surfaces. This collision creates surface melts and collision bonding results in electron sharing linkups.

  3. Safety harness

    DOEpatents

    Gunter, Larry W.

    1993-01-01

    A safety harness to be worn by a worker, especially a worker wearing a plastic suit thereunder for protection in a radioactive or chemically hostile environment, which safety harness comprises a torso surrounding portion with at least one horizontal strap for adjustably securing the harness about the torso, two vertical shoulder straps with rings just forward of the of the peak of the shoulders for attaching a life-line and a pair of adjustable leg supporting straps releasibly attachable to the torso surrounding portion. In the event of a fall, the weight of the worker, when his fall is broken and he is suspended from the rings with his body angled slightly back and chest up, will be borne by the portion of the leg straps behind his buttocks rather than between his legs. Furthermore, the supporting straps do not restrict the air supplied through hoses into his suit when so suspended.

  4. Sequential modelling of ICRF wave near RF fields and asymptotic RF sheaths description for AUG ICRF antennas

    NASA Astrophysics Data System (ADS)

    Jacquot, Jonathan; Tierens, Wouter; Zhang, Wei; Bobkov, Volodymyr; Colas, Laurent; Noterdaeme, Jean-Marie

    2017-10-01

    A sequence of simulations is performed with RAPLICASOL and SSWICH to compare two AUG ICRF antennas. RAPLICASOL outputs have been used as input to SSWICH-SW for the AUG ICRF antennas. Using parallel electric field maps and the scattering matrix produced by RAPLICASOL, SSWICH-SW, reduced to its asymptotic part, is able to produce a 2D radial/poloidal map of the DC plasma potential accounting for the antenna input settings (total power, power balance, phasing). Two models of antennas are compared: 2-strap antenna vs 3-strap antenna. The 2D DC potential structures are correlated to structures of the parallel electric field map for different phasing and power balance. The overall DC plasma potential on the 3-strap antenna is lower due to better global RF currents compensation. Spatial proximity between regions of high RF electric field and regions where high DC plasma potentials are observed is an important factor for sheath rectification.

  5. 77 FR 26663 - Airworthiness Directives; The Boeing Company Model 767-200, -300, -300F, and -400ER Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-07

    ... removing corrosion from fail-safe straps. We have received Boeing Service Bulletin 767-53A0100, Revision 3.... That AD currently requires inspections to detect cracking or corrosion of the fail-safe straps between... cracks in 51 fail-safe straps on 41 airplanes; we have also received a report of a crack found in the ``T...

  6. Acceptability and functionality of the "Kettle Strap": An attempt to decrease kettle related burns in children.

    PubMed

    Makhubalo, Obakeng; Schulman, Dorothy; Rode, Heinz; Cox, Sharon

    2018-05-15

    Extensive hot water burns (HWB) are common at Red Cross War Memorial Children's Hospital (RCWMCH). The majority are caused by kettle scalds. These burn injuries usually affect toddlers living in poor socio-economic circumstances. The majority of these injuries are preventable. This trial aims to demonstrate the acceptability and functionality of the Kettle Strap as a kettle safety device. The feedback will be used for a public awareness program marketed by the Child Accident Prevention Foundation of Southern Africa and ChildSafe as part of their mandate to reduce kettle related thermal injuries. 50 caregivers of children at RCWMCH were given a Kettle Strap for use in their homes, 25 with kettle related burns (Group I) and 25 who had no history of burns (Group II). All participants were instructed on Kettle Strap installation and use. Telephonic interviews on the acceptability and functionality of the strap occurred 1 month and 1 year later. The average age in Groups I and II was 25 and 22 months respectively. In Group I, the average burn surface area was 15%. Nineteen (76%) of the accidents occurred in the kitchen. Eighteen (72%) received immediate first aid. Twelve (48%) in Group I and 15 (60%) in Group II lived in formal housing. The majority of caregivers (90%) indicated that installation was quick and easy and thought that the Kettle Strap would prevent kettle burns. At 1 month follow-up, all the participants in Group I indicated that they would continue using the apparatus and felt greater protection compared to 84% of Group II. Only 40% indicated that use of the Kettle Strap raised awareness of other possible household dangers. Thirty participants were available telephonically after 1 year, 22 of these were still using the device, others had moved or lost their homes to fire. All participants had informed neighbors about the Kettle Strap and burn safety. The participants were prepared to pay ZAR 44 for the complete apparatus. The Kettle Strap is an acceptable, affordable device to improve kettle safety in the home. Copyright © 2018 Elsevier Ltd and ISBI. All rights reserved.

  7. Using Shoulder Straps Decreases Heart Rate Variability and Salivary Cortisol Concentration in Swedish Ambulance Personnel.

    PubMed

    Karlsson, Kåre J; Niemelä, Patrik H; Jonsson, Anders R; Törnhage, Carl-Johan A

    2016-03-01

    Previous research has shown that paramedics are exposed to risks in the form of injuries to the musculoskeletal system. In addition, there are studies showing that they are also at increased risk of cardiovascular disease, cancer, and psychiatric diseases, which can partly be explained by their constant exposure to stress. The aim of this study is to evaluate whether the use of shoulder straps decreases physical effort in the form of decreased heart rate and cortisol concentration. A stretcher with a dummy was carried by 20 participants for 400 m on two occasions, one with and one without the shoulder straps. Heart rate was monitored continuously and cortisol samples were taken at intervals of 0 minutes, 15 minutes, 30 minutes, 45 minutes, and 60 minutes. Each participant was her or his own control. A significant decrease in heart rate and cortisol concentration was seen when shoulder straps were used. The median values for men (with shoulder straps) at 0 minutes was 78 bpm/21.1 nmol/L (heart rate/cortisol concentration), at 15 minutes was 85 bpm/16.9 nmol/L, and at 60 minutes was 76 bpm/15.7 nmol/L; for men without shoulder straps, these values were 78 bpm/21.9 nmol/L, 93 bpm/21.9 nmol/L, and 73 bpm/20.5 nmol/L. For women, the values were 85 bpm/23.3 nmol/L, 92 bpm/20.8 nmol/L, and 70 bpm/18.4 nmol/L and 84 bpm/32.4 nmol/L, 100 bpm/32.5 nmol/L, and 75 bpm/25.2 nmol/L, respectively. The use of shoulder straps decreases measurable physical stress and should therefore be implemented when heavy equipment or a stretcher needs to be carried. An easy way to ensure that staff use these or similar lifting aids is to provide them with personalized, well-adapted shoulder straps. Another better option would be to routinely sewn these straps into the staff's personal alarm jackets so they are always in place and ready to be used.

  8. Cyclic debonding of adhesively bonded composites

    NASA Technical Reports Server (NTRS)

    Mall, S.; Johnson, W. S.; Everett, R. A., Jr.

    1982-01-01

    The fatigue behavior of a simple composite to composite bonded joint was analyzed. The cracked lap shear specimen subjected to constant amplitude cyclic loading was studied. Two specimen geometries were tested for each bonded system: (1) a strap adherend of 16 plies bonded to a lap adherend of 8 plies; and (2) a strap adherend of 8 plies bonded to a lap adherend of 16 plies. In all specimens the fatigue failure was in the form of cyclic debonding with some 0 deg fiber pull off from the strap adherend. The debond always grew in the region of adhesive that had the highest mode (peel) loading and that region was close to the adhesive strap interface.

  9. Effects of Angle Variations in Suspension Push-up Exercise.

    PubMed

    Gulmez, Irfan

    2017-04-01

    Gulmez, I. Effects of angle variations in suspension push-up exercise. J Strength Cond Res 31(4): 1017-1023, 2017-This study aimed to determine and compare the amount of loads on the TRX Suspension Trainer (TRX) straps and ground reaction forces at 4 different angles during TRX push-ups. Twenty-eight male (mean age, 24.1 ± 2.9 years; height, 179.4 ± 8.0 m; weight, 78.8 ± 9.8 kg) physical education and sports university students participated in this study. The subjects were tested at TRX angles (0, 15, 30, 45°) during the TRX push-ups. Force data were recorded by a force platform and load cells integrated into the TRX straps. The results show that as the TRX angle was reduced, the load applied to the TRX straps increased and simultaneously the load measured by the force platform decreased. This was true for both the elbow joint changing from flexion to extension and vice versa. When the TRX angle was set at 0° and subjects' elbows were at extension during TRX push-up, 50.4% of the subjects' body weight, and when the elbows were at flexion, 75.3% of the body weight was registered by the sensors on the TRX straps. The results of this study can be used in the calculation of the training load and volume (resistance training programming) during TRX push-up exercises at varying angles.

  10. Ultra-Flexible Thermal Bus for Use in the Astro-H Adiabatic Demagnetization Refrigerator

    NASA Technical Reports Server (NTRS)

    Kimball, Mark O.; Shirron, Peter J.

    2015-01-01

    The adiabatic demagnetization refrigerator (ADR) developed for the Astro-H Soft-X-ray Spectrometer (SXS) is a multi-stage solid-state cooler. It is capable of holding the SXS detector array at 0.050 K for greater than 24 hours with a recycle time of less than one hour. This quick recycle time relies upon high-conductivity thermal straps to couple the individual stages to a pair of heat switches without imposing a lateral load on the paramagnetic salt pills. To accomplish this we construct thermal straps using a technique of diffusion bonding together the ends of high-purity copper straps leaving the length between as individual foils. A thermal bus created this way has a thermal conductivity comparable to a solid strap of the equivalent thickness but with much-increased flexibility. The technique for selecting the base material, machining, cleaning, forming into final shape, and finally bonding together individual foils will be discussed along with examples of complete straps in various geometries.

  11. International Space Station (ISS)

    NASA Image and Video Library

    2001-03-01

    In this Space Shuttle STS-102 mission image, the Payload Equipment Restraint System H-Strap is shown at the left side of the U.S. Laboratory hatch and behind Astronaut James D. Weatherbee, mission specialist. PERS is an integrated modular system of components designed to assist the crew of the International Space Station (ISS) in restraining and carrying necessary payload equipment and tools in a microgravity environment. The Operations Development Group, Flight Projects Directorate at the Marshall Space Flight Center (MSFC), while providing operation support to the ISS Materials Science Research Facility (MSRF), recognized the need for an on-orbit restraint system to facilitate control of lose objects, payloads, and tools. The PERS is the offspring of that need and it helps the ISS crew manage tools and rack components that would otherwise float away in the near-zero gravity environment aboard the Space Station. The system combines Kevlar straps, mesh pockets, Velcro and a variety of cornecting devices into a portable, adjustable system. The system includes the Single Strap, the H-Strap, the Belly Pack, the Laptop Restraint Belt, and the Tool Page Case. The Single Strap and the H-Strap were flown on this mission. The PERS concept was developed by industrial design students at Auburn University and the MSFC Flight Projects Directorate.

  12. Exertional dyspnea associated with chest wall strapping is reduced when external dead space substitutes for part of the exercise stimulus to ventilation.

    PubMed

    Garske, Luke A; Lal, Ravin; Stewart, Ian B; Morris, Norman R; Cross, Troy J; Adams, Lewis

    2017-05-01

    Chest wall strapping has been used to assess mechanisms of dyspnea with restrictive lung disease. This study examined the hypothesis that dyspnea with restriction depends principally on the degree of reflex ventilatory stimulation. We compared dyspnea at the same (iso)ventilation when added dead space provided a component of the ventilatory stimulus during exercise. Eleven healthy men undertook a randomized controlled crossover trial that compared four constant work exercise conditions: 1 ) control (CTRL): unrestricted breathing at 90% gas exchange threshold (GET); 2 ) CTRL+dead space (DS): unrestricted breathing with 0.6-l dead space, at isoventilation to CTRL due to reduced exercise intensity; 3 ) CWS: chest wall strapping at 90% GET; and 4 ) CWS+DS: chest strapping with 0.6-l dead space, at isoventilation to CWS with reduced exercise intensity. Chest strapping reduced forced vital capacity by 30.4 ± 2.2% (mean ± SE). Dyspnea at isoventilation was unchanged with CTRL+DS compared with CTRL (1.93 ± 0.49 and 2.17 ± 0.43, 0-10 numeric rating scale, respectively; P = 0.244). Dyspnea was lower with CWS+DS compared with CWS (3.40 ± 0.52 and 4.51 ± 0.53, respectively; P = 0.003). Perceived leg fatigue was reduced with CTRL+DS compared with CTRL (2.36 ± 0.48 and 2.86 ± 0.59, respectively; P = 0.049) and lower with CWS+DS compared with CWS (1.86 ± 0.30 and 4.00 ± 0.79, respectively; P = 0.006). With unrestricted breathing, dead space did not change dyspnea at isoventilation, suggesting that dyspnea does not depend on the mode of reflex ventilatory stimulation in healthy individuals. With chest strapping, dead space presented a less potent stimulus to dyspnea, raising the possibility that leg muscle work contributes to dyspnea perception independent of the ventilatory stimulus. NEW & NOTEWORTHY Chest wall strapping was applied to healthy humans to simulate restrictive lung disease. With chest wall strapping, dyspnea was reduced when dead space substituted for part of a constant exercise stimulus to ventilation. Dyspnea associated with chest wall strapping depended on the contribution of leg muscle work to ventilatory stimulation. Chest wall strapping might not be a clinically relevant model to determine whether an alternative reflex ventilatory stimulus mimics the intensity of exertional dyspnea. Copyright © 2017 the American Physiological Society.

  13. Does the Powers™ strap influence the lower limb biomechanics during running?

    PubMed

    Greuel, Henrike; Herrington, Lee; Liu, Anmin; Jones, Richard K

    2017-09-01

    Previous research has reported a prevalence of running related injuries in 25.9% to 72% of all runners. A greater hip internal rotation and adduction during the stance phase in running has been associated with many running related injuries, such as patellofemoral pain. Researchers in the USA designed a treatment device 'the Powers™ strap' to facilitate an external rotation of the femur and to thereby control abnormal hip and knee motion during leisure and sport activities. However, to date no literature exists to demonstrate whether the Powers™ strap is able to reduce hip internal rotation during running. 22 healthy participants, 11 males and 11 females (age: 27.45±4.43 years, height: 1.73±0.06m, mass: 66.77±9.24kg) were asked to run on a 22m track under two conditions: without and with the Powers™ strap. Three-dimensional motion analysis was conducted using ten Qualisys OQUS 7 cameras (Qualisys AB, Sweden) and force data was captured with three AMTI force plates (BP600900, Advanced Mechanical Technology, Inc.USA). Paired sample t-tests were performed at the 95% confidence interval on all lower limb kinematic and kinetic data. The Powers™ strap significantly reduced hip and knee internal rotation throughout the stance phase of running. These results showed that the Powers™ strap has the potential to influence hip motion during running related activities, in doing so this might be beneficial for patients with lower limb injuries. Future research should investigate the influence of the Powers™ strap in subjects who suffer from running related injuries, such as patellofemoral pain. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Website malfunction: a case report highlighting the danger of using electrical insulating tape for buddy strapping

    PubMed Central

    Devitt, Brian Meldan; Baker, Joseph F; Fitzgerald, Eilis; McCarthy, Conor

    2010-01-01

    A case of injury to the third web space of the right hand of a rugby player, as a result of buddy strapping with electrical insulating tape of the little and ring finger, is presented. A deep laceration of the web space and distal palmar fascia resulted, necessitating wound exploration and repair. This case highlights the danger of using electrical insulating tape as a means to buddy strap fingers. PMID:22736733

  15. Damage Tolerance Testing of a NASA TransHab Derivative Woven Inflatable Module

    NASA Technical Reports Server (NTRS)

    Edgecombe, John; delaFuente, Horacio; Valle, Gerard

    2009-01-01

    Current options for Lunar habitat architecture include inflatable habitats and airlocks. Inflatable structures can have mass and volume advantages over conventional structures. However, inflatable structures carry different inherent risks and are at a lower Technical Readiness Level (TRL) than more conventional metallic structures. One of the risks associated with inflatable structures is in understanding the tolerance to induced damage. The Damage Tolerance Test (DTT) is designed to study the structural integrity of an expandable structure. TransHab (Figure 1) was an experimental inflatable module developed at the NASA/Johnson Space Center in the 1990 s. The TransHab design was originally envisioned for use in Mars Transits but was also studied as a potential habitat for the International Space Station (ISS). The design of the TransHab module was based on a woven design using an Aramid fabric. Testing of this design demonstrated a high level of predictability and repeatability with analytical predictions of stresses and deflections. Based on JSC s experience with the design and analysis of woven inflatable structures, the Damage Tolerance Test article was designed and fabricated using a woven design. The DTT article was inflated to 45 psig, representing 25% of the ultimate burst pressure, and one of the one-inch wide longitudinal structural members was severed by initiating a Linear Shaped Charge (LSC). Strain gage measurements, at the interface between the expandable elements (straps) and the nonexpandable metallic elements for pre-selected longitudinal straps, were taken throughout pressurization of the module and strap separation. Strain gage measurements show no change in longitudinal strap loading at the bulkhead interface after strap separation indicating loads in the restraint layer were re-distributed local to the damaged area due to the effects of friction under high internal pressure loading. The test completed all primary objectives with better than expected results. This paper will discuss space inflatable structures, damage tolerance analysis, test results, and applicability to the Lunar architecture.

  16. Process for producing elements from a fused bath using a metal strap and ceramic electrode body nonconsumable electrode assembly

    DOEpatents

    Byrne, Stephen C.

    1984-01-01

    A nonconsumable electrode assembly suitable for use in the production of metal by electrolytic reduction of a metal compound dissolved in a molten salt, the assembly comprising a ceramic electrode body and a metal subassembly of a metal conductor rod and at least one metal strap affixed to an end of the rod with opposing portions extending radially outwardly from the rod axis and having the ends of the strap attached to the electrode body.

  17. 29 CFR 1926.959 - Lineman's body belts, safety straps, and lanyards.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.959 Lineman's body belts, safety straps, and lanyards. (a) General...

  18. 29 CFR 1926.959 - Lineman's body belts, safety straps, and lanyards.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.959 Lineman's body belts, safety straps, and lanyards. (a) General...

  19. 29 CFR 1926.959 - Lineman's body belts, safety straps, and lanyards.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.959 Lineman's body belts, safety straps, and lanyards. (a) General...

  20. 29 CFR 1926.959 - Lineman's body belts, safety straps, and lanyards.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR CONSTRUCTION Power Transmission and Distribution § 1926.959 Lineman's body belts, safety straps, and lanyards. (a) General...

  1. 49 CFR 236.532 - Strap iron inductor; use restricted.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.532 Strap iron...

  2. 49 CFR 236.532 - Strap iron inductor; use restricted.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., INSPECTION, MAINTENANCE, AND REPAIR OF SIGNAL AND TRAIN CONTROL SYSTEMS, DEVICES, AND APPLIANCES Automatic Train Stop, Train Control and Cab Signal Systems Rules and Instructions; Roadway § 236.532 Strap iron...

  3. FemCap with removal strap: ease of removal, safety and acceptability.

    PubMed

    Mauck, Christine K; Weiner, Debra H; Creinin, Mitchell D; Archer, David F; Schwartz, Jill L; Pymar, Helen C; Ballagh, Susan A; Henry, Deborah M; Callahan, Marianne M

    2006-01-01

    FemCap is a silicone-rubber barrier contraceptive approved for marketing in the United States. To address reported problems with removal and dislodgment, the device's developer added a strap to the device and increased the height of the brim. This trial assessed whether the new design reduced removal difficulties and had any effects on dislodgment, genital pain/discomfort, safety, and acceptability. Women used the strapped device for 8 weeks with follow-up visits at 2 and 8 weeks. Outcome measures were obtained through diary cards, questionnaires, and naked eye examination. Data from these 120 women were compared with data from 419 women who used the unstrapped FemCap in a previous contraceptive effectiveness study. The strapped device was not significantly easier for users to remove than the unstrapped device. Similar odds of dislodgment and cervical/vaginal irritation were seen with the two devices. Both female and male participants were significantly more likely to report pain/discomfort with use of the strapped device. Female users of the strapped device were significantly more likely to say they disliked their device. In six weeks, two pregnancies were observed, but pregnancy was not an endpoint in the study and no conclusions should be drawn regarding pregnancy rates. The modifications to the FemCap did not significantly improve the ease of device removal and appears to have resulted in significantly more female and male partner pain/discomfort and decreased acceptability, compared with the unstrapped device.

  4. Bipedicled strap muscle transposition for vocal fold deficit after laser cordectomy in early glottic cancer patients.

    PubMed

    Su, Chih-Ying; Chuang, Hui-Ching; Tsai, Shang-Shyue; Chiu, Jeng-Fen

    2005-03-01

    In treating early glottic carcinomas, the outcomes of endoscopic laser cordectomy have been proven to be valuable in local control, survival, and vocal function preservation. In some extended cases, however, laser cordectomy may leave patients with poor vocal function because of vocal fold deficit. This work assesses the vocal outcome of medialization laryngoplasty with bipedicled strap muscle transposition for vocal fold deficit resulting from laser cordectomy in early glottic cancer patients. A prospective clinical series. Thirteen early glottic cancer patients who had vocal fold deficit caused by previous laser cordectomy underwent medialization laryngoplasty with bipedicled strap muscle transposition. The thyroid lamina on the cordectomy side was paramedially separated. The inner perichondrium was circumspectly raised from the overlying thyroid cartilage. After separating the thyrohyoid and cricothyroid membranes, the lamina was retracted laterally. A bipedicled strap muscle flap was then transposed into the area between the lamina and the paraglottic soft tissue. The thyroid cartilages were carefully sutured back in position. All patients received pre- and postoperative voice assessments comprising laryngostroboscopy and vocal function studies. Vocal enhancement was present in 92% (12/13) of patients after medialization laryngoplasty with strap muscle transposition. The glottal closure and maximal phonation time were noticeably improved by surgery. No dyspnea or other significant complications were observed in any patients. The outcomes show that bipedicled strap muscle transposition is a prosthesis-free, safe, and valuable laryngoplastic technique for correcting glottal incompetence caused by endoscopic laser cordectomy in early glottic cancer patients.

  5. Analysis of the phase control of the ITER ICRH antenna array. Influence on the load resilience and radiated power spectrum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Messiaen, A., E-mail: a.messiaen@fz-juelich.de; Ongena, J.; Vervier, M.

    2015-12-10

    The paper analyses how the phasing of the ITER ICRH 24 strap array evolves from the power sources up to the strap currents of the antenna. The study of the phasing control and coherence through the feeding circuits with prematching and automatic matching and decoupling network is made by modeling starting from the TOPICA matrix of the antenna array for a low coupling plasma profile and for current drive phasing (worst case for mutual coupling effects). The main results of the analysis are: (i) the strap current amplitude is well controlled by the antinode V{sub max} amplitude of the feedingmore » lines, (ii) the best toroidal phasing control is done by the adjustment of the mean phase of V{sub max} of each poloidal straps column, (iii) with well adjusted system the largest strap current phasing error is ±20°, (iv) the effect on load resilience remains well below the maximum affordable VSWR of the generators, (v) the effect on the radiated power spectrum versus k{sub //} computed by means of the coupling code ANTITER II remains small for the considered cases.« less

  6. Hammer toe repair

    MedlinePlus

    ... causing: Pain Irritation Sores Problems finding shoes that fit Skin infections Surgery may not be advised if: Treatment with paddings and strapping works You can still straighten your toe Changing to different shoe types can alleviate symptoms

  7. Process for producing elements from a fused bath using a metal strap and ceramic electrode body nonconsumable electrode assembly

    DOEpatents

    Byrne, S.C.

    1984-07-03

    A nonconsumable electrode assembly is described suitable for use in the production of metal by electrolytic reduction of a metal compound dissolved in a molten salt, the assembly comprising a ceramic electrode body and a metal subassembly of a metal conductor rod and at least one metal strap affixed to an end of the rod with opposing portions extending radially outwardly from the rod axis and having the ends of the strap attached to the electrode body. 7 figs.

  8. A NEW CLINICAL MUSCLE FUNCTION TEST FOR ASSESSMENT OF HIP EXTERNAL ROTATION STRENGTH: AUGUSTSSON STRENGTH TEST.

    PubMed

    Augustsson, Jesper

    2016-08-01

    Dynamic clinical tests of hip strength applicable on patients, non-athletes and athletes alike, are lacking. The aim of this study was therefore to develop and evaluate the reliability of a dynamic muscle function test of hip external rotation strength, using a novel device. A second aim was to determine if gender differences exist in absolute and relative hip strength using the new test. Fifty-three healthy sport science students (34 women and 19 men) were tested for hip external rotation strength using a device that consisted of a strap connected in series with an elastic resistance band loop, and a measuring tape connected in parallel with the elastic resistance band. The test was carried out with the subject side lying, positioned in 45 ° of hip flexion and the knees flexed to 90 ° with the device firmly fastened proximally across the knees. The subject then exerted maximal concentric hip external rotation force against the device thereby extending the elastic resistance band. The displacement achieved by the subject was documented by the tape measure and the corresponding force production was calculated. Both right and left hip strength was measured. Fifteen of the subjects were tested on repeated occasions to evaluate test-retest reliability. No significant test-retest differences were observed. Intra-class correlation coefficients ranged 0.93-0.94 and coefficients of variation 2.76-4.60%. In absolute values, men were significantly stronger in hip external rotation than women (right side 13.2 vs 11.0 kg, p = 0.001, left side 13.2 vs 11.5 kg, p = 0.002). There were no significant differences in hip external rotation strength normalized for body weight (BW) between men and women (right side 0.17 kg/BW vs 0.17 kg/BW, p = 0.675, left side 0.17 kg/BW vs 0.18 kg/BW, p = 0.156). The new muscle function test showed high reliability and thus could be useful for measuring dynamic hip external rotation strength in patients, non-athletes and athletes. The test is practical and easy to perform in any setting and could therefore provide additional information to the common clinical hip examination, in the rehabilitation or research setting, as well as when conducting on-the-field testing in sports. 3.

  9. Venous Ulcers

    PubMed Central

    Caprini, J.A.; Partsch, H.; Simman, R.

    2013-01-01

    Venous leg ulcers are the most frequent form of wounds seen in patients. This article presents an overview on some practical aspects concerning diagnosis, differential diagnosis and treatment. Duplex ultrasound investigations are essential to ascertain the diagnosis of the underlying venous pathology and to treat venous refluxes. Differential diagnosis includes mainly other vascular lesions (arterial, microcirculatory causes), hematologic and metabolic diseases, trauma, infection, malignancies. Patients with superficial venous incompetence may benefit from endovenous or surgical reflux abolition diagnosed by Duplex ultrasound. The most important basic component of the management is compression therapy, for which we prefer materials with low elasticity applied with high initial pressure (short-stretch bandages and Velcro-strap devices). Local treatment should be simple, absorbing and not sticky dressings keeping adequate moisture balance after debridement of necrotic tissue and biofilms are preferred. After the ulcer is healed compression therapy should be continued in order to prevent recurrence. PMID:26236636

  10. Design, modeling and testing of a one-way energy harvesting backpack

    NASA Astrophysics Data System (ADS)

    Mi, Jia; Xu, Lin; Zhu, Ziheng; Liu, Mingyi; Zuo, Lei

    2018-04-01

    During trips and outdoor adventures, there are a lot of electric equipment and thus power supply for those devices is critical. At the same time, the burden on shoulders from heavy baggage is substantial. This paper presents a one-way energy harvesting backpack with ball-screw mechanism to generate electricity with high efficiency and reliability, while relieves the burden on shoulders. The one-way energy harvesting method only harvests negative work from human body and potentially reduce metabolic cost while carrying backpack. Simulations show that 4.5W of electrical energy can be obtained from human walking. Bench test results indicate this system can obtain an average power of 7.3 W with excitation of 2Hz and 25mm direct drive. Treadmill test to verify the performance of burden relieve on shoulders indicates this one-way design combing with elastic support strap can reduce the force on shoulders, which reduce fatigue in human.

  11. Nasal CPAP and preterm bradycardia: cause or cure.

    PubMed

    MacLaren, Andrew Torrance; Peters, Colin; MacDonald, Peter D

    2014-05-23

    Nasal continuous positive airway pressure (nCPAP) is widely used for the treatment of respiratory distress syndrome and apnoea of prematurity. Complications related to fixation devices have been well documented. We report a clinically well preterm baby suffering intermittent, profound episodes of bradycardia without any prior associated apnoea or desaturation. We believe these episodes were due to the oculocardiac reflex related to orbital compression from the continuous positive airway pressure (CPAP) fixation straps. Bradycardia was replicated by gentle ocular compression and the episodes resolved after repositioning the CPAP straps. Vagal overstimulation has previously been reported in preterm babies but we believe this to be the first case in which pressure from CPAP strapping has been reported to trigger bradycardia. However, we suspect that similar cases could easily go unrecognised. Careful positioning of CPAP securing straps may prevent accidental vagal overstimulation contributing to episodic bradycardia. 2014 BMJ Publishing Group Ltd.

  12. Non-invasive quantification of lower limb mechanical alignment in flexion

    PubMed Central

    Deakin, Angela; Fogg, Quentin A.; Picard, Frederic

    2014-01-01

    Objective Non-invasive navigation techniques have recently been developed to determine mechanical femorotibial alignment (MFTA) in extension. The primary aim of this study was to evaluate the precision and accuracy of an image-free navigation system with new software designed to provide multiple kinematic measurements of the knee. The secondary aim was to test two types of strap material used to attach optical trackers to the lower limb. Methods Seventy-two registrations were carried out on 6 intact embalmed cadaveric specimens (mean age: 77.8 ± 12 years). A validated fabric strap, bone screws and novel rubber strap were used to secure the passive tracker baseplate for four full experiments with each knee. The MFTA angle was measured under the conditions of no applied stress, valgus stress, and varus stress. These measurements were carried out at full extension and at 30°, 40°, 50° and 60° of flexion. Intraclass correlation coefficients, repeatability coefficients, and limits of agreement (LOA) were used to convey precision and agreement in measuring MFTA with respect to each of the independent variables, i.e., degree of flexion, applied coronal stress, and method of tracker fixation. Based on the current literature, a repeatability coefficient and LOA of ≤3° were deemed acceptable. Results The mean fixed flexion for the 6 specimens was 12.8° (range: 6–20°). The mean repeatability coefficient measuring MFTA in extension with screws or fabric strapping of the baseplate was ≤2°, compared to 2.3° using rubber strapping. When flexing the knee, MFTA measurements taken using screws or fabric straps remained precise (repeatability coefficient ≤3°) throughout the tested range of flexion (12.8–60°); however, using rubber straps, the repeatability coefficient was >3° beyond 50° flexion. In general, applying a varus/valgus stress while measuring MFTA decreased precision beyond 40° flexion. Using fabric strapping, excellent repeatability (coefficient ≤2°) was observed until 40° flexion; however, beyond 50° flexion, the repeatability coefficient was >3°. As was the case with precision, agreement between the invasive and non-invasive systems was satisfactory in extension and worsened with flexion. Mean limits of agreement between the invasive and non-invasive system using fabric strapping to assess MFTA were 3° (range: 2.3–3.8°) with no stress applied and 3.9° (range: 2.8–5.2°) with varus and valgus stress. Using rubber strapping, the corresponding values were 4.4° (range: 2.8–8.5°) with no stress applied, 5.5° (range: 3.3–9.0°) with varus stress, and 5.6° (range: 3.3–11.9°) with valgus stress. Discussion Acceptable precision and accuracy may be possible when measuring knee kinematics in early flexion using a non-invasive system; however, we do not believe passive trackers should be mounted with rubber strapping such as was used in this study. Flexing the knee appears to decrease the precision and accuracy of the system. The functions of this new software using image-free navigation technology have many potential clinical applications, including assessment of bony and soft tissue deformity, pre-operative planning, and post-operative evaluation, as well as in further pure research comparing kinematics of the normal and pathological knee. PMID:24856249

  13. 77 FR 28240 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-14

    ... multiple site damage cracks in the radial web lap and tear strap splices of the aft pressure bulkhead at... multiple site damage cracks in the radial web lap and tear strap splices of the aft pressure bulkhead at...

  14. Systems tunnel linear shaped charge lightning strike

    NASA Technical Reports Server (NTRS)

    Cook, M.

    1989-01-01

    Simulated lightning strike testing of the systems tunnel linear shaped charge (LSC) was performed at the Thiokol Lightning Test Complex in Wendover, Utah, on 23 Jun. 1989. The test article consisted of a 160-in. section of the LSC enclosed within a section of the systems tunnel. The systems tunnel was bonded to a section of a solid rocket motor case. All test article components were full scale. The systems tunnel cover of the test article was subjected to three discharges (each discharge was over a different grounding strap) from the high-current generator. The LSC did not detonate. All three grounding straps debonded and violently struck the LSC through the openings in the systems tunnel floor plates. The LSC copper surface was discolored around the areas of grounding strap impact, and arcing occurred at the LSC clamps and LSC ends. This test verified that the present flight configuration of the redesigned solid rocket motor systems tunnel, when subjected to simulated lightning strikes with peak current levels within 71 percent of the worst-case lightning strike condition of NSTS-07636, is adequate to prevent LSC ignition. It is therefore recommended that the design remain unchanged.

  15. Tensile properties of a morphologically split supraspinatus tendon.

    PubMed

    Matsuhashi, Tomoya; Hooke, Alexander W; Zhao, Kristin D; Goto, Akira; Sperling, John W; Steinmann, Scott P; An, Kai-Nan

    2014-07-01

    The supraspinatus tendon consists morphologically of two sub-regions, anterior and posterior. The anterior sub-region is thick and tubular while the posterior is thin and strap-like. The purpose of this study was to compare the structural and mechanical properties of the anterior and posterior sub-regions of the supraspinatus tendon. The supraspinatus tendons from seven human cadaveric shoulders were morphologically divided into the anterior and posterior sub-regions. Length, width, and thickness were measured. A servo-hydraulic testing machine (MTS Systems Corporation, Minneapolis, MN) was used for tensile testing. The maximal load at failure, modulus of elasticity and ultimate tendon stress were calculated. Repeated measures were used for statistical comparisons. The mean anterior tendon cross-sectional area was 47.3 mm(2) and the posterior was 32.1 mm(2) . Failure occurred most often at the insertion site: anterior (5/7) and posterior (6/7). All parameters of the anterior sub-region were significantly greater than those of the posterior sub-region. The moduli of elasticity at the insertion site were 592.4 MPa in the anterior sub-region and 217.7 MPa in the posterior (P = 0.01). The ultimate failure loads were 779.2 N in the anterior sub-region and 335.6 N in the posterior (P = 0.003). The ultimate stresses were 22.1 MPa in the anterior sub-region and 11.6 MPa in the posterior (P = 0.008). We recognized that the anterior and posterior sub-regions of the SSP tendon have significantly different mechanical properties. In a future study, we need to evaluate how best to repair an SSP tendon considering these region-specific properties. Copyright © 2013 Wiley Periodicals, Inc.

  16. 76 FR 51459 - Office of Commercial Space Transportation (AST); Notice of Availability of the Finding of No...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-18

    ... five solid-propellant strap-on rocket motors to the Atlas V launch vehicle and larger solid- propellant strap-on rocket motors on the Delta IV vehicle. The FAA participated as a cooperating agency in...

  17. 29 CFR 1918.84 - Bulling cargo.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) SAFETY AND HEALTH REGULATIONS FOR LONGSHORING Handling Cargo § 1918.84 Bulling cargo. (a) Bulling cargo... from padeyes, straps, or beam clamps. Snatch blocks or straps shall not be made fast to batten cleats...

  18. 24 CFR 3285.402 - Ground anchor installations.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Anchorage Against Wind § 3285... conforming to ASTM D 3953—97, Standard Specification for Strapping, Flat Steel and Seals (incorporated by... in ASTM D 3953-97, Standard Specification for Strapping, Flat Steel and Seals (incorporated by...

  19. 24 CFR 3285.402 - Ground anchor installations.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... HOUSING AND URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Anchorage Against Wind § 3285... conforming to ASTM D 3953—97, Standard Specification for Strapping, Flat Steel and Seals (incorporated by... in ASTM D 3953-97, Standard Specification for Strapping, Flat Steel and Seals (incorporated by...

  20. Method and apparatus for animal positioning in imaging systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hadjioannou, Arion-Xenofon; Stout, David B.; Silverman, Robert W.

    An apparatus for imaging an animal includes a first mounting surface, a bed sized to support the animal and releasably secured to or integral with the first mounting surface. The apparatus also includes a plurality of straps, each having a first end in a fixed position relative to the bed and a second end for tightening around a limb of the animal. A method for in-vivo imaging of an animal includes providing an animal that has limbs, providing a first mounting surface, and providing a bed removably secured to or integral with the mounting surface and sized to support themore » animal as well as being coupled to a plurality of straps. The method also includes placing the animal on the bed between the plurality of straps and tightening at least two of the plurality of straps around at least two of the limbs such that the animal is substantially secured in place relative to the bed.« less

  1. First results of the Piton de la Fournaise STRAP 2015 experiment: multidisciplinary tracking of a volcanic gas and aerosol plume

    NASA Astrophysics Data System (ADS)

    Tulet, Pierre; Di Muro, Andréa; Colomb, Aurélie; Denjean, Cyrielle; Duflot, Valentin; Arellano, Santiago; Foucart, Brice; Brioude, Jérome; Sellegri, Karine; Peltier, Aline; Aiuppa, Alessandro; Barthe, Christelle; Bhugwant, Chatrapatty; Bielli, Soline; Boissier, Patrice; Boudoire, Guillaume; Bourrianne, Thierry; Brunet, Christophe; Burnet, Fréderic; Cammas, Jean-Pierre; Gabarrot, Franck; Galle, Bo; Giudice, Gaetano; Guadagno, Christian; Jeamblu, Fréderic; Kowalski, Philippe; Leclair de Bellevue, Jimmy; Marquestaut, Nicolas; Mékies, Dominique; Metzger, Jean-Marc; Pianezze, Joris; Portafaix, Thierry; Sciare, Jean; Tournigand, Arnaud; Villeneuve, Nicolas

    2017-04-01

    The STRAP (Synergie Transdisciplinaire pour Répondre aux Aléas liés aux Panaches volcaniques) campaign was conducted over the entire year of 2015 to investigate the volcanic plumes of Piton de La Fournaise (La Réunion, France). For the first time, measurements at the local (near the vent) and at the regional scales were conducted around the island. The STRAP 2015 campaign has become possible thanks to strong cross-disciplinary collaboration between volcanologists and meteorologists. The main observations during four eruptive periods (85 days) are summarised. They include the estimates of SO2, CO2 and H2O emissions, the altitude of the plume at the vent and over different areas of La Réunion Island, the evolution of the SO2 concentration, the aerosol size distribution and the aerosol extinction profile. A climatology of the volcanic plume dispersion is also reported. Simulations and measurements show that the plumes formed by weak eruptions have a stronger interaction with the surface of the island. Strong SO2 mixing ratio and particle concentrations above 1000 ppb and 50 000 cm-3 respectively are frequently measured over a distance of 20 km from Piton de la Fournaise. The measured aerosol size distribution shows the predominance of small particles in the volcanic plume. Several cases of strong nucleation of sulfuric acid have been observed within the plume and at the distal site of the Maïdo observatory. The STRAP 2015 campaign provides a unique set of multi-disciplinary data that can now be used by modellers to improve the numerical parameterisations of the physical and chemical evolution of the volcanic plumes.

  2. Plastic debris straps on threatened blue shark Prionace glauca.

    PubMed

    Colmenero, Ana I; Barría, Claudio; Broglio, Elisabetta; García-Barcelona, Salvador

    2017-02-15

    Juveniles of blue shark Prionace glauca caught in pelagic longlines targeting tuna and swordfish in the Atlantic Ocean and the Mediterranean Sea were found entangled with plastic straps around their gill region. The plastic debris were identified as strapping bands and caused several degrees of injuries on the dorsal musculature and pectoral fins. They were also obstructing the gill slits probably causing breathing issues. These records were uploaded in the web site seawatchers.org, and highlight the potential of citizen science in revealing the occurrence of such problems which could help to measure the effects of plastic debris on marine life. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. 77 FR 59728 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-01

    ... correct installation of certain bonding straps, and applicable corrective actions. This new AD adds... the potential of ignition sources inside fuel tanks in the event of a severe lightning strike, which... installation of certain bonding straps, and applicable corrective actions. That NPRM also proposed to add...

  4. 76 FR 51459 - Office of Commercial Space Transportation (AST); Notice of Availability of the Record of Decision...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-18

    ... impacts of up to five solid-propellant strap-on rocket motors (SRMs) on the Atlas V medium lift vehicle... Proposed Action in the 2000 SEIS, up to five solid- propellant strap-on rocket motors (SRMs) would be added...

  5. 24 CFR 3285.606 - Ductwork connections.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Ductwork and Plumbing and Fuel Supply... type duct, the straps must be at least 1/2″ wider than the spacing of the metal spirals encasing the duct. The ducts must be installed such that the straps cannot slip between any two spirals and arranged...

  6. 46 CFR 160.060-3 - Materials-standard vests.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) EQUIPMENT, CONSTRUCTION, AND MATERIALS..., Adult and Child § 160.060-3 Materials—standard vests. (a) General. All components used in the... body strap loops. The tie tapes and body strap loops for both adult and child sizes must be 3/4-inch...

  7. 49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening... acceleration in a lateral direction. (2) Working Load limit. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to...

  8. 49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening... acceleration in a lateral direction. (2) Working Load limit. Tiedown assemblies (including chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to...

  9. 24 CFR 3285.606 - Ductwork connections.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Ductwork and Plumbing and Fuel Supply... type duct, the straps must be at least 1/2″ wider than the spacing of the metal spirals encasing the duct. The ducts must be installed such that the straps cannot slip between any two spirals and arranged...

  10. 77 FR 50414 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-21

    ... the drain mast bolts, an inspection to determine the location of the bonding strap, a measurement of... determine the location of the bonding strap, a measurement of the washers under the drain mast bolts, and... measurement. hour = $340. We estimate the following costs to do certain necessary conditional actions that...

  11. 49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening..., steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to... contained within the structure of the vehicle. Securement systems must provide a downward force equivalent...

  12. 49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening..., steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to... contained within the structure of the vehicle. Securement systems must provide a downward force equivalent...

  13. 49 CFR 393.102 - What are the minimum performance criteria for cargo securement devices and systems?

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... chains, wire rope, steel strapping, synthetic webbing, and cordage) and other attachment or fastening..., steel strapping, synthetic webbing, and cordage) and other attachment or fastening devices used to... contained within the structure of the vehicle. Securement systems must provide a downward force equivalent...

  14. 78 FR 60807 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-02

    ... frequency eddy current (HFEC) inspection of the bear strap; External detailed and HFEC inspections of the... 737-53A1329, dated June 4, 2013, specifies contacting the manufacturer for inspection instructions... an internal detailed inspection of the skin assembly and bear strap, an internal high frequency eddy...

  15. Deceleration-Limiting Roadway Barrier

    NASA Technical Reports Server (NTRS)

    Schneider, William C. (Inventor); Locke, P. James (Inventor)

    2006-01-01

    Roadway barrier system and method are disclosed for decelerating a moving vehicle in a controlled manner and for retaining the decelerated vehicle. A net or mesh of the roadway barrier system receives and captures the moving vehicle. The net or mesh is secured to anchors by energy absorbing straps. The energy absorbing straps deploy under a tensional load to decelerate the moving vehicle, the straps providing a controlled resistance to the tensional load over a predefined displacement or stroke to bring the moving vehicle to rest. Additional features include a sacrificial panel or sheet in front of the net that holds up the net or mesh while deflecting vehicles that collide only tangentially with the roadway barrier system.

  16. 29 CFR 1915.151 - Scope, application and definitions.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... deceleration devices. Body belt means a strap with means for both securing it about the waist and attaching it to a lanyard, lifeline, or deceleration device. Body harness means straps which may be secured about.... Connector means a device which is used to couple (connect) parts of a personal fall arrest system or parts...

  17. 29 CFR 1915.151 - Scope, application and definitions.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... deceleration devices. Body belt means a strap with means for both securing it about the waist and attaching it to a lanyard, lifeline, or deceleration device. Body harness means straps which may be secured about.... Connector means a device which is used to couple (connect) parts of a personal fall arrest system or parts...

  18. 29 CFR 1915.151 - Scope, application and definitions.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... deceleration devices. Body belt means a strap with means for both securing it about the waist and attaching it to a lanyard, lifeline, or deceleration device. Body harness means straps which may be secured about.... Connector means a device which is used to couple (connect) parts of a personal fall arrest system or parts...

  19. Electromyographic Control of a Hands-Free Electrolarynx Using Neck Strap Muscles

    ERIC Educational Resources Information Center

    Kubert, Heather L.; Stepp, Cara E.; Zeitels, Steven M.; Gooey, John E.; Walsh, Michael J.; Prakash, S. R.; Hillman, Robert E.; Heaton, James T.

    2009-01-01

    Three individuals with total laryngectomy were studied for their ability to control a hands-free electrolarynx (EL) using neck surface electromyography (EMG) for on/off and pitch modulation. The laryngectomy surgery of participants was modified to preserve neck strap musculature for EMG-based EL control (EMG-EL), with muscles on one side…

  20. 50 CFR 660.130 - Trawl fishery-management measures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... transfer cables, lifting or splitting straps (chokers), but must be: over riblines and restraining straps... footrope, or small footrope) is on board, either simultaneously or successively, at any time during a... of 40°10′ N. lat. with any type of small footrope gear onboard the vessel at any time during the...

  1. 46 CFR 160.048-3 - Materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... fabrics shall comply with the requirements of Federal Specification CCC-C-426 for Type I, Class 3 material... not less than 0.008 inch in thickness meeting the requirements of Federal Specification L-P-375 for Type I or II, Class 1, film. (f) Grab straps. The grab straps shall be of materials permitted for the...

  2. Non-invasive method and apparatus for measuring pressure within a pliable vessel

    NASA Technical Reports Server (NTRS)

    Shimizu, M. (Inventor)

    1983-01-01

    A non-invasive method and apparatus is disclosed for measuring pressure within a pliable vessel such as a blood vessel. The blood vessel is clamped by means of a clamping structure having a first portion housing a pressure sensor and a second portion extending over the remote side of the blood vessel for pressing the blood vessel into engagement with the pressure sensing device. The pressure sensing device includes a flat deflectable diaphragm portion arranged to engage a portion of the blood vessel flattened against the diaphragm by means of the clamp structure. In one embodiment, the clamp structure includes first and second semicylindrical members held together by retaining rings. In a second embodiment the clamp structure is of one piece construction having a solid semicylindrical portion and a hollow semicylindrical portion with a longitudinal slot in the follow semicylindrical portion through which a slip the blood vessel. In a third embodiment, an elastic strap is employed for clamping the blood vessel against the pressure sensing device.

  3. A tethering system for direct measurement of cardiovascular function in the caged baboon

    NASA Technical Reports Server (NTRS)

    Byrd, L. D.

    1979-01-01

    A device suitable for the continuous measurement of physiological activity in large, conscious monkeys has permitted the direct recording of systemic arterial blood pressure and heart rate in caged baboons. The device comprises a lightweight fiberglass backpack, retained in place on the baboon by a thoracic elastic band and shoulder straps, and a flexible stainless steel tether connecting the pack to an electrocannular slip-ring in the top center of the baboon's cage. A chronically indwelling arterial catheter inserted retrograde into the abdominal aorta via the internal iliac artery and connected to a small pressure transducer on the pack provides direct measurement of blood pressure and heart rate. Body fluids can be sampled or drugs administered via an indwelling catheter in the inferior vena cava. Electrical and fluid connections between the fiberglass pack and recording and infusion equipment located outside the cage pass through the flexible tether and remain protected from the subject. The reliability of the tethering system has been demonstrated in physiological, pharmacological, and behavioral experiments with baboons.

  4. Design of an Electronic Chest-Band

    NASA Astrophysics Data System (ADS)

    Atakan, R.; Acikgoz Tufan, H.; Baskan, H.; Eryuruk, S. H.; Akalin, N.; Kose, H.; Li, Y.; Kursun Bahadir, S.; Kalaoglu, F.

    2017-10-01

    In this study, an electronic chest strap prototype was designed for measuring fitness level, performance optimization, mobility and fall detection. Knitting technology is used for production by using highly elastic nylon yarn. In order to evaluate comfort performance of the garment, yarn strength and elongation, air permeability, moisture management and FAST tests (Fabric Assurance Fabric Testing) were carried out, respectively. After testing of textile part of the chest band, IMU sensors were integrated onto the garment by means of conductive yarns. Electrical conductivity of the circuit was also assessed at the end. Results indicated that the weight and the thickness of the product are relatively high for sports uses and it has a negative impact on comfort properties. However, it is highly stretchable and moisture management properties are still in acceptable values. From the perspective of possible application areas, developed smart chest band in this research could be used in sports facilities as well as health care applications for elderly and disabled people.

  5. The attachment of collagenous ligament to stereom in primary spines of the sea-urchin, Eucidaris tribuloides.

    PubMed

    Smith, D S; Del Castillo, J; Morales, M; Luke, B

    1990-01-01

    The similar proximal and distal attachments to the stereom of primary spine ligament in the echinoid Eucidaris tribuloides are described, from thin sections and SEM studies on frozen and fractured spine articulations and ligaments from decalcified material. The orthogonal structure of the general stereom is modified on the attachment zones where bundles of collagen cylinders enter approximately hexagonally arranged channels. Straps of collagen extend in parallel series between adjacent bundles via regularly placed ports and collagen loops rather than non-striated 'tendons' pass over skeletal trabeculae. The regular pattern of collagen straps is most evident on the proximal and distal attachment zones. Mechanical features of the non-adhesive mode of attachment are considered, together with similarities and differences between insertion of muscle cells and mutable collagenous tissue (ligament) in echinoderms.

  6. The physical demands of Olympic yacht racing.

    PubMed

    Mackie, H; Sanders, R; Legg, S

    1999-12-01

    The primary purpose of this study was to quantify the up wards forces of the feet on the hiking strap and the forces in the mainsheet of four Olympic classes of racing dinghies (Europe, Laser. Finn and 470) during realistic on-water sailing in varying wind conditions. The secondary aim of the study was to measure the joint angles adopted by the sailors and boat heel angles. The tertiary aim was to identify events and sailing conditions associated with large or patterned force production. Forces in the hiking strap and mainsheet of four classes of Olympic sailing dinghies were measured on eleven New Zealand sailors during simulated on-water racing in a range of wind conditions. Up-wind hiking strap forces reached an average of 73-87% of predicted maximal voluntary contraction (pred MVC), with peak forces exceeding 100% pred MVC. Mainsheet forces reached 25-35% pred MVC, with peak forces reaching 40-50% pred MVC. Off-wind hiking strap and mainsheet forces were considerably lower than up-wind forces. Ankle and hip joint angles increased and knee joint angles decreased with increasing wind speed during up-wind sailing. Large forces occurred in the hiking strap and mainsheet when boats reached the tops of wave during up-wind sailing in high wind speeds and when a gust of wind hit the boat. During off-wind sailing large forces were observed in the mainsheet when surfing down waves. It is recommended that the intensities and joint angles found in this study be used as a basis for the development of class specific off-water physical conditioning programmes.

  7. 76 FR 52593 - Airworthiness Directives; Eurocopter Canada Ltd. Model BO 105 LS A-3 Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-23

    ... fatigue failure of a TT strap, loss of a blade, and subsequent loss of control of the helicopter. DATES... failure of a TT strap, loss of a blade, and subsequent loss of control of the helicopter. Since issuing... ASB also describes and contains a graph for determining the revised life limit, and provides various...

  8. 76 FR 10288 - Airworthiness Directives; The Boeing Company Model 767-200, -300, -300F, and -400ER Series Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-24

    ... and corrosion to an area within five inches of the fail-safe strap. Revision 2 of this service.... The existing AD currently requires inspections to detect cracking or corrosion of the fail-safe straps... corrective actions. Since we issued that AD, we have received additional reports of cracks in 51 fail-safe...

  9. Real-time strap pressure sensor system for powered exoskeletons.

    PubMed

    Tamez-Duque, Jesús; Cobian-Ugalde, Rebeca; Kilicarslan, Atilla; Venkatakrishnan, Anusha; Soto, Rogelio; Contreras-Vidal, Jose Luis

    2015-02-16

    Assistive and rehabilitative powered exoskeletons for spinal cord injury (SCI) and stroke subjects have recently reached the clinic. Proper tension and joint alignment are critical to ensuring safety. Challenges still exist in adjustment and fitting, with most current systems depending on personnel experience for appropriate individual fastening. Paraplegia and tetraplegia patients using these devices have impaired sensation and cannot signal if straps are uncomfortable or painful. Excessive pressure and blood-flow restriction can lead to skin ulcers, necrotic tissue and infections. Tension must be just enough to prevent slipping and maintain posture. Research in pressure dynamics is extensive for wheelchairs and mattresses, but little research has been done on exoskeleton straps. We present a system to monitor pressure exerted by physical human-machine interfaces and provide data about levels of skin/body pressure in fastening straps. The system consists of sensing arrays, signal processing hardware with wireless transmission, and an interactive GUI. For validation, a lower-body powered exoskeleton carrying the full weight of users was used. Experimental trials were conducted with one SCI and one able-bodied subject. The system can help prevent skin injuries related to excessive pressure in mobility-impaired patients using powered exoskeletons, supporting functionality, independence and better overall quality of life.

  10. A new B-dot probe-based diagnostic for amplitude, polarization, and wavenumber measurements of ion cyclotron range-of frequency fields on ASDEX Upgrade

    NASA Astrophysics Data System (ADS)

    Ochoukov, R.; Bobkov, V.; Faugel, H.; Fünfgelder, H.; Noterdaeme, J.-M.

    2015-11-01

    A new B-dot probe-based diagnostic has been installed on an ASDEX Upgrade tokamak to characterize ion cyclotron range-of frequency (ICRF) wave generation and interaction with magnetized plasma. The diagnostic consists of a field-aligned array of B-dot probes, oriented to measure fast and slow ICRF wave fields and their field-aligned wavenumber (k//) spectrum on the low field side of ASDEX Upgrade. A thorough description of the diagnostic and the supporting electronics is provided. In order to compare the measured dominant wavenumber of the local ICRF fields with the expected spectrum of the launched ICRF waves, in-air near-field measurements were performed on the newly installed 3-strap ICRF antenna to reconstruct the dominant launched toroidal wavenumbers (ktor). Measurements during a strap current phasing scan in tokamak discharges reveal an upshift in k// as strap phasing is moved away from the dipole configuration. This result is the opposite of the ktor trend expected from in-air near-field measurements; however, the near-field based reconstruction routine does not account for the effect of induced radiofrequency (RF) currents in the passive antenna structures. The measured exponential increase in the local ICRF wave field amplitude is in agreement with the upshifted k//, as strap phasing moves away from the dipole configuration. An examination of discharges heated with two ICRF antennas simultaneously reveals the existence of beat waves at 1 kHz, as expected from the difference of the two antennas' operating frequencies. Beats are observed on both the fast and the slow wave probes suggesting that the two waves are coupled outside the active antennas. Although the new diagnostic shows consistent trends between the amplitude and the phase measurements in response to changes applied by the ICRF antennas, the disagreement with the in-air near-field measurements remains. An electromagnetic model is currently under development to address this issue.

  11. A new B-dot probe-based diagnostic for amplitude, polarization, and wavenumber measurements of ion cyclotron range-of frequency fields on ASDEX Upgrade.

    PubMed

    Ochoukov, R; Bobkov, V; Faugel, H; Fünfgelder, H; Noterdaeme, J-M

    2015-11-01

    A new B-dot probe-based diagnostic has been installed on an ASDEX Upgrade tokamak to characterize ion cyclotron range-of frequency (ICRF) wave generation and interaction with magnetized plasma. The diagnostic consists of a field-aligned array of B-dot probes, oriented to measure fast and slow ICRF wave fields and their field-aligned wavenumber (k(//)) spectrum on the low field side of ASDEX Upgrade. A thorough description of the diagnostic and the supporting electronics is provided. In order to compare the measured dominant wavenumber of the local ICRF fields with the expected spectrum of the launched ICRF waves, in-air near-field measurements were performed on the newly installed 3-strap ICRF antenna to reconstruct the dominant launched toroidal wavenumbers (k(tor)). Measurements during a strap current phasing scan in tokamak discharges reveal an upshift in k(//) as strap phasing is moved away from the dipole configuration. This result is the opposite of the k(tor) trend expected from in-air near-field measurements; however, the near-field based reconstruction routine does not account for the effect of induced radiofrequency (RF) currents in the passive antenna structures. The measured exponential increase in the local ICRF wave field amplitude is in agreement with the upshifted k(//), as strap phasing moves away from the dipole configuration. An examination of discharges heated with two ICRF antennas simultaneously reveals the existence of beat waves at 1 kHz, as expected from the difference of the two antennas' operating frequencies. Beats are observed on both the fast and the slow wave probes suggesting that the two waves are coupled outside the active antennas. Although the new diagnostic shows consistent trends between the amplitude and the phase measurements in response to changes applied by the ICRF antennas, the disagreement with the in-air near-field measurements remains. An electromagnetic model is currently under development to address this issue.

  12. Electromyographic analysis of traditional and nontraditional abdominal exercises: implications for rehabilitation and training.

    PubMed

    Escamilla, Rafael F; Babb, Eric; DeWitt, Ryan; Jew, Patrick; Kelleher, Patrick; Burnham, Toni; Busch, Juliann; D'Anna, Kristen; Mowbray, Ryan; Imamura, Rodney T

    2006-05-01

    Performing nontraditional abdominal exercises with devices such as abdominal straps, the Power Wheel, and the Ab Revolutionizer has been suggested as a way to activate abdominal and extraneous (nonabdominal) musculature as effectively as more traditional abdominal exercises, such as the crunch and bent-knee sit-up. The purpose of this study was to test the effectiveness of traditional and nontraditional abdominal exercises in activating abdominal and extraneous musculature. Twenty-one men and women who were healthy and between 23 and 43 years of age were recruited for this study. Surface electromyography (EMG) was used to assess muscle activity from the upper and lower rectus abdominis, external and internal oblique, rectus femoris, latissimus dorsi, and lumbar paraspinal muscles while each exercise was performed. The EMG data were normalized to maximum voluntary muscle contractions. Differences in muscle activity were assessed by a 1-way, repeated-measures analysis of variance. Upper and lower rectus abdominis, internal oblique, and latissimus dorsi muscle EMG activity were highest for the Power Wheel (pike, knee-up, and roll-out), hanging knee-up with straps, and reverse crunch inclined 30 degrees. External oblique muscle EMG activity was highest for the Power Wheel (pike, knee-up, and roll-out) and hanging knee-up with straps. Rectus femoris muscle EMG activity was highest for the Power Wheel (pike and knee-up), reverse crunch inclined 30 degrees, and bent-knee sit-up. Lumbar paraspinal muscle EMG activity was low and similar among exercises. The Power Wheel (pike, knee-up, and roll-out), hanging knee-up with straps, and reverse crunch inclined 30 degrees not only were the most effective exercises in activating abdominal musculature but also were the most effective in activating extraneous musculature. The relatively high rectus femoris muscle activity obtained with the Power Wheel (pike and knee-up), reverse crunch inclined 30 degrees, and bent-knee sit-up may be problematic for some people with low back problems.

  13. Oklahoma Higher Education: Challenging the Conventional Wisdom

    ERIC Educational Resources Information Center

    Denhart, Matthew; Matgouranis, Christopher

    2011-01-01

    A major headline in recent years has been that cash-strapped state governments are cutting back support for many services, including public higher education. Oklahoma is no different. Indeed, in the most recent state budget crafted by Oklahoma policymakers, Oklahoma's public colleges and universities received a 5.8 percent cut in state…

  14. Ankle taping: support given by different materials.

    PubMed Central

    Capasso, G; Maffulli, N; Testa, V

    1989-01-01

    Three different adhesive and two non-adhesive tapes were used by three operators to assess the compressive action exerted on the ankle at the moment of strapping, during different phases of gait, and after some days of treatment in ten volunteers. Only the adhesive tapes were still able to prevent swelling after five days. They should be used if a prolonged compressive action is required. Images Figure 1 PMID:2517042

  15. Glass/Epoxy Door Panel for Automobiles

    NASA Technical Reports Server (NTRS)

    Bauer, J. L. JR.

    1985-01-01

    Lightweight panel cost-effective. Integrally-molded intrusion strap key feature of composite outer door panel. Strap replaces bulky and heavy steel instrusion beam of conventional door. Standard steel inner panel used for demonstration purposes. Door redesigned to exploit advantages of composite outer panel thinner. Outer panel for automobilie door, made of glass/epoxy composite material, lighter than conventional steel door panel, meets same strength requirements, and less expensive.

  16. Software Tool for Researching Annotations of Proteins (STRAP): Open-Source Protein Annotation Software with Data Visualization

    PubMed Central

    Bhatia, Vivek N.; Perlman, David H.; Costello, Catherine E.; McComb, Mark E.

    2009-01-01

    In order that biological meaning may be derived and testable hypotheses may be built from proteomics experiments, assignments of proteins identified by mass spectrometry or other techniques must be supplemented with additional notation, such as information on known protein functions, protein-protein interactions, or biological pathway associations. Collecting, organizing, and interpreting this data often requires the input of experts in the biological field of study, in addition to the time-consuming search for and compilation of information from online protein databases. Furthermore, visualizing this bulk of information can be challenging due to the limited availability of easy-to-use and freely available tools for this process. In response to these constraints, we have undertaken the design of software to automate annotation and visualization of proteomics data in order to accelerate the pace of research. Here we present the Software Tool for Researching Annotations of Proteins (STRAP) – a user-friendly, open-source C# application. STRAP automatically obtains gene ontology (GO) terms associated with proteins in a proteomics results ID list using the freely accessible UniProtKB and EBI GOA databases. Summarized in an easy-to-navigate tabular format, STRAP includes meta-information on the protein in addition to complimentary GO terminology. Additionally, this information can be edited by the user so that in-house expertise on particular proteins may be integrated into the larger dataset. STRAP provides a sortable tabular view for all terms, as well as graphical representations of GO-term association data in pie (biological process, cellular component and molecular function) and bar charts (cross comparison of sample sets) to aid in the interpretation of large datasets and differential analyses experiments. Furthermore, proteins of interest may be exported as a unique FASTA-formatted file to allow for customizable re-searching of mass spectrometry data, and gene names corresponding to the proteins in the lists may be encoded in the Gaggle microformat for further characterization, including pathway analysis. STRAP, a tutorial, and the C# source code are freely available from http://cpctools.sourceforge.net. PMID:19839595

  17. Padded self-adhesive strap immobilization following newborn bladder exstrophy closure: the Utah straps.

    PubMed

    Wallis, M Chad; Oottamasathien, Siam; Wicher, Chris; Hadley, David; Snow, Brent W; Cartwright, Patrick C

    2013-12-01

    Several methods have been described for immobilization of the pelvis following bladder exstrophy closure, which can be challenging to manage. We hypothesized that immobilization can be significantly simplified using a modified mermaid wrap with padded Velcro® straps around the thigh and lower leg. We retrospectively reviewed all patients who underwent bladder exstrophy closure in the newborn period at our institution from 1990 through 2010. Patients with cloacal exstrophy and those who underwent delayed closure due to other medical conditions were excluded. We collected data on closure technique, length of stay and complications of the primary closure as outcomes. A total of 20 boys and 7 girls underwent closure of classic bladder exstrophy. Followup ranged from 2 to 22 years. Seven boys underwent complete primary repair and 13 underwent staged repair. All patients had the legs stabilized with a modified wrap technique using 2 lengths of Velcro straps lined with self-adhering open cell foam pads for 3 weeks. Complications of exstrophy closure included bladder dehiscence in 1 patient (4%) and incisional hernia in 2 (7%). Following complete primary repair urethrocutaneous fistula developed in 2 patients and urethral stricture in 2. Average length of stay for patients without significant prematurity was 15 days. Padded Velcro strap immobilization simplifies postoperative care, provides secure fixation, decreases length of stay, and enables parents to hold and bond with the child shortly after repair. We advocate this simplified technique, which can be applied with a rate of complications that is comparable to other procedures. Copyright © 2013 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  18. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abushakra, Bass

    The aging tests conducted so far showed that duct tape tends to degrade in its performance as the joint it is applied to requires a geometrical description of a higher number of space dimensions (1-D, 2-D, 3-D). One-dimensional joints are the easiest to seal with duct tape, and thus the least to experience failure. Two-dimensional joints, such as the flexible duct core-to-collar joints tested in this study, are less likely to fail than three-dimensional collar-to-plenum joints, as the shrinkage could have a positive effect in tightening the joint. Three-dimensional joints are the toughest to seal and the most likely tomore » experience failure. The 2-D flexible duct core-to-collar joints passed the six-month period of the aging test in terms of leakage, but with the exception of the foil-butyl tape, showed degradation in terms hardening, brittleness, partial peeling, shrinkage, wrinkling, delamination of the tape layers, flaking, cracking, bubbling, oozing and discoloration. The baking test results showed that the failure in the duct tape joints could be attributed to the type of combination of the duct tape and the material it is applied to, as the duct tape behaves differently with different substrates. Overall, the foil-butyl tape (Tape 4) had the best results, while the film tape (Tape 3) showed the most deterioration. The conventional duct tapes tested (Tape 1 and Tape 2) were between these two extremes, with Tape 2 performing better than Tape 1. Lastly, we found that plastic straps became discolored and brittle during the tests, and a couple of straps broke completely. Therefore, we recommend that clamping the duct-taped flexible core-to-collar joints should be done with metallic adjustable straps.« less

  19. The Feasibility of Instituting a Department Head Screen in the Naval Special Warfare Community.

    DTIC Science & Technology

    1985-12-01

    community, and through use of the Structured Accession Planning System for Officers (STRAP-O) model, projects the community from 1985 to 1991 both with and...Placement Officer. It looks at the current state of the NSW community, and through use of the Structured Accession Planning System for Officers (STRAP-0...ACCESSION PLANNING SYSTEM FOR OFFICERS----------------------------------------19 Ill. NAVAL SPECIAL WARFARE COMMUNITY RESPONSE TO PROPOSAL

  20. Using Bonding Enamel-Coated Steel Fixtures to Produce More Durable Brick/Masonry Structures

    DTIC Science & Technology

    2010-02-01

    Initial tests with enameled metal straps cracked all the test cylinders and straps would not pull out BUILDING STRONG® New Strong Durable Ties...BUILDING STRONG® Using Bonding Enamel -Coated Steel Fixtures to Produce More Durable Brick/Masonry Structures Principal Investigator: Steven C...COVERED 00-00-2010 to 00-00-2010 4. TITLE AND SUBTITLE Using Bonding Enamel -Coated Steel Fixtures to Produce More Durable Brick/Masonry

  1. Banning the Strap: The End of Corporal Punishment in Canadian Schools

    ERIC Educational Resources Information Center

    Axelrod, Paul

    2011-01-01

    The long historical debate over the physical discipline and punishment of children arose from different perspectives on appropriate forms of child rearing and pedagogy. At one end of the spectrum were adults and educators who believed that social order, good behaviour, and moral development required the regular use of disciplinary instruments such…

  2. Real-Time Strap Pressure Sensor System for Powered Exoskeletons

    PubMed Central

    Tamez-Duque, Jesús; Cobian-Ugalde, Rebeca; Kilicarslan, Atilla; Venkatakrishnan, Anusha; Soto, Rogelio; Contreras-Vidal, Jose Luis

    2015-01-01

    Assistive and rehabilitative powered exoskeletons for spinal cord injury (SCI) and stroke subjects have recently reached the clinic. Proper tension and joint alignment are critical to ensuring safety. Challenges still exist in adjustment and fitting, with most current systems depending on personnel experience for appropriate individual fastening. Paraplegia and tetraplegia patients using these devices have impaired sensation and cannot signal if straps are uncomfortable or painful. Excessive pressure and blood-flow restriction can lead to skin ulcers, necrotic tissue and infections. Tension must be just enough to prevent slipping and maintain posture. Research in pressure dynamics is extensive for wheelchairs and mattresses, but little research has been done on exoskeleton straps. We present a system to monitor pressure exerted by physical human-machine interfaces and provide data about levels of skin/body pressure in fastening straps. The system consists of sensing arrays, signal processing hardware with wireless transmission, and an interactive GUI. For validation, a lower-body powered exoskeleton carrying the full weight of users was used. Experimental trials were conducted with one SCI and one able-bodied subject. The system can help prevent skin injuries related to excessive pressure in mobility-impaired patients using powered exoskeletons, supporting functionality, independence and better overall quality of life. PMID:25690551

  3. High-harmonic fast magnetosonic wave coupling, propagation, and heating in a spherical torus plasma

    NASA Astrophysics Data System (ADS)

    Menard, J.; Majeski, R.; Kaita, R.; Ono, M.; Munsat, T.; Stutman, D.; Finkenthal, M.

    1999-05-01

    A novel rotatable two-strap antenna has been installed in the current drive experiment upgrade (CDX-U) [T. Jones, Ph.D. thesis, Princeton University (1995)] in order to investigate high-harmonic fast wave coupling, propagation, and electron heating as a function of strap angle and strap phasing in a spherical torus plasma. Radio-frequency-driven sheath effects are found to fit antenna loading trends at very low power and become negligible above a few kilowatts. At sufficiently high power, the measured coupling efficiency as a function of strap angle is found to agree favorably with cold plasma wave theory. Far-forward microwave scattering from wave-induced density fluctuations in the plasma core tracks the predicted fast wave loading as the antenna is rotated. Signs of electron heating during rf power injection have been observed in CDX-U with central Thomson scattering, impurity ion spectroscopy, and Langmuir probes. While these initial results appear promising, damping of the fast wave on thermal ions at high ion-cyclotron-harmonic number may compete with electron damping at sufficiently high ion β—possibly resulting in a significantly reduced current drive efficiency and production of a fast ion population. Preliminary results from ray-tracing calculations which include these ion damping effects are presented.

  4. Thermally-Activated, Delayed Fluorescence in O,B,O- and N,B,O-Strapped Boron Dipyrromethene Derivatives.

    PubMed

    Stachelek, Patrycja; Alsimaree, Abdulrahman A; Alnoman, Rua B; Harriman, Anthony; Knight, Julian G

    2017-03-16

    A small series of boron dipyrromethene (BODIPY) dyes has been synthesized whereby the boron atom is constrained in a five-membered ring formed from either o-dihydroxypyridine or o-aminophenol. In the latter case, the amino group has been converted into the corresponding amide derivative so as to curtail the possibility for light-induced charge transfer from strap to BODIPY. These compounds are weakly emissive in fluid solution but cleavage of the strap, by treatment with a photoacid generator, restores strong fluorescence. Surprisingly, the same compounds remain weakly fluorescent in a rigid glass at 80 K where light-induced charge transfer is most unlikely. In fluid solution, the fluorescence quantum yield increases with increasing temperature due to a thermally activated step but does not correlate with the thermodynamics for intramolecular charge transfer. It is proposed that the strap causes rupture of the potential energy surface for the excited state, creating traps that provide new routes by which the wave packet can return to the ground state. Access to the trap from the excited state is reversible, leading to the delayed emission. Analysis of the temperature dependent emission intensities allows estimation of the kinetic parameters associated with entering and leaving the trap.

  5. Role of the Windlass in Improvised Tourniquet Use on a Manikin Hemorrhage Model

    DTIC Science & Technology

    2015-01-01

    windlass to better understand the role of the windlass in tightening the tourniquet strap. Methods: An experiment was designed to test the...longer bystanders, these responders gave first aid by wrapping and tightening a shirt around a limb, and these makeshift tourniquets reportedly helped...improvising tourniquets is to twist a strap with a windlass to gain mechanical advantage in tightening . However, to our knowledge, no one in Boston

  6. Lightning tests and analyses of tunnel bond straps and shielded cables on the Space Shuttle solid rocket booster

    NASA Technical Reports Server (NTRS)

    Druen, William M.

    1993-01-01

    The purposes of the tests and analyses described in this report are as follows: (1) determine the lightning current survivability of five alternative changed designs of the bond straps which electrically bond the solid rocket booster (SRB) systems tunnel to the solid rocket motor (SRM) case; (2) determine the amount of reduction in induced voltages on operational flight (OF) tunnel cables obtained by a modified design of tunnel bond straps (both tunnel cover-to-cover and cover-to-motor case); (3) determine the contribution of coupling to the OF tunnel cables by ground electrical and instrumentation (GEI) cables which enter the systems tunnel from unshielded areas on the surfaces of the motor case; and (4) develop a model (based on test data) and calculate the voltage levels at electronic 'black boxes' connected to the OF cables that run in the systems tunnel.

  7. The Compensation Question: Are Public School Teachers Underpaid? Analysis and Opinion

    ERIC Educational Resources Information Center

    Mishel, Lawrence

    2012-01-01

    Over the past few years, as cash-strapped states and school districts have faced tough budget decisions, spending on teacher compensation has come under the microscope. The underlying question is whether teachers are fairly paid, underpaid, or overpaid. In this forum, two pairs of respected economists offer very different answers. Andrew Biggs of…

  8. Aeromechanical stability of helicopters with a bearingless main rotor. Part 1: Equations of motion

    NASA Technical Reports Server (NTRS)

    Hodges, D. H.

    1978-01-01

    Equations of motion for a coupled rotor-body system were derived for the purpose of studying air and ground resonance characteristics of helicopters that have bearingless main rotors. For the fuselage, only four rigid body degrees of freedom are considered; longitudinal and lateral translations, pitch, and roll. The rotor is assumed to consist of three or more rigid blades. Each blade is joined to the hub by means of a flexible beam segment (flexbeam or strap). Pitch change is accomplished by twisting the flexbeam with the pitch-control system, the characteristics of which are variable. Thus, the analysis is capable of implicitly treating aeroelastic couplings generated by the flexbeam elastic deflections, the pitch-control system, and the angular offsets of the blade and flexbeam. The linearized equations are written in the nonrotating system retaining only the cyclic rotor modes; thus, they comprise a system of homogeneous ordinary differential equations with constant coefficients. All contributions to the linearized perturbation equations from inertia, gravity, quasi-steady aerodynamics, and the flexbeam equilibrium deflections are retained exactly.

  9. Follow-on cable coupling lightning test. Volume 2: Appendixes A, B, C, and D

    NASA Technical Reports Server (NTRS)

    1990-01-01

    The following information from the follow-on cable coupling lightning test of the Space Shuttle Booster is presented: (1) resistance measurements (cover-to-cover and cover-to-floor plate); (2) resistance measurements (external bond strap-to-case); (3) resistance measurements (internal bond strap-to-case) and; (4) follow-on cable coupling lightning test data plots. The bulk of the document comprises the follow-on cable coupling lightning test data plots.

  10. New system speeds bundling of split firewood

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    1979-01-01

    A firewood compacting and strapping machine is manufactured by Carolson Stapler and Shippers Supply, Omaha, and FMC Industrial Packaging Division, Philadelphia. A hydraulic compactor applies 20,000 lbs of compressive force to each bundle of split logs, reducing each package to a diameter of about 12 inches. A polypropylene band is applied and heat sealed around each bundle. Bundles are stacked on end, twenty-four to a pallet, and the entire load is banded with one horizontal strap.

  11. The Role of Lug Preheating, Melt Pool Temperature, and Lug Entrance Delay on the Cast-on-Strap Joining Process

    NASA Astrophysics Data System (ADS)

    Pahlavan, Sohrab; Nikpour, Saman; Mirjalili, Mostafa; Alagheband, Ali; Azimi, Mohammadyousef; Taji, Iman

    2017-07-01

    This work deals with effective parameters in the cast-on-strap (COS) process during which grid lugs of a lead-acid battery are joined together by a strap. The effects of lug preheating, melt pool temperature, and lug entrance delay on the quality of joints and casting defects were investigated. Lug preheating was found to propitiously reduce joint internal voids because of flux elimination. Its adverse effect on lowering lug wettability, however, made it unfavorable under the experimental conditions. The melt pool temperature also showed a two-sided effect depending on the process conditions. Raising the temperature increases the strap melt fluidity, which improves the joint contact area; however, it has a negative effect on lug wettability by flux evaporation. Besides, higher temperatures cause more lug back-melting and, hence, lower relative contact lengths. Therefore, an intermediate temperature of 683 K (410 °C) was found to make the most proper condition. Moreover, the case at which the lugs enter the mold coincident with its filling by the melt rendered the best joint quality. In this condition, the melt flows through the interlug spaces, which helps the voids to escape, resulting in the better joint interface. As the conclusion, the lug entrance time has the most effective role on joint quality, considering that lug preheating does not show any improving effect.

  12. A new B-dot probe-based diagnostic for amplitude, polarization, and wavenumber measurements of ion cyclotron range-of frequency fields on ASDEX Upgrade

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ochoukov, R.; Bobkov, V.; Faugel, H.

    2015-11-15

    A new B-dot probe-based diagnostic has been installed on an ASDEX Upgrade tokamak to characterize ion cyclotron range-of frequency (ICRF) wave generation and interaction with magnetized plasma. The diagnostic consists of a field-aligned array of B-dot probes, oriented to measure fast and slow ICRF wave fields and their field-aligned wavenumber (k{sub //}) spectrum on the low field side of ASDEX Upgrade. A thorough description of the diagnostic and the supporting electronics is provided. In order to compare the measured dominant wavenumber of the local ICRF fields with the expected spectrum of the launched ICRF waves, in-air near-field measurements were performedmore » on the newly installed 3-strap ICRF antenna to reconstruct the dominant launched toroidal wavenumbers (k{sub tor}). Measurements during a strap current phasing scan in tokamak discharges reveal an upshift in k{sub //} as strap phasing is moved away from the dipole configuration. This result is the opposite of the k{sub tor} trend expected from in-air near-field measurements; however, the near-field based reconstruction routine does not account for the effect of induced radiofrequency (RF) currents in the passive antenna structures. The measured exponential increase in the local ICRF wave field amplitude is in agreement with the upshifted k{sub //}, as strap phasing moves away from the dipole configuration. An examination of discharges heated with two ICRF antennas simultaneously reveals the existence of beat waves at 1 kHz, as expected from the difference of the two antennas’ operating frequencies. Beats are observed on both the fast and the slow wave probes suggesting that the two waves are coupled outside the active antennas. Although the new diagnostic shows consistent trends between the amplitude and the phase measurements in response to changes applied by the ICRF antennas, the disagreement with the in-air near-field measurements remains. An electromagnetic model is currently under development to address this issue.« less

  13. Follow-on cable coupling lightning test, volume 1

    NASA Technical Reports Server (NTRS)

    Danforth, Richard

    1990-01-01

    A redesigned solid rocket motor test article was subjected to simulated lightning strikes. This test was performed to evaluate the effects of lightning strike to the redesigned motor and Space Transportation System. The purpose of the test was to evaluate the performance of systems tunnel design changes when subjected to the lightning discharges. The goal of the design changes was to reduce lightning induced coupling to cables within the systems tunnel. The test article was subjected to several different amounts and kinds of discharges. Changes in coupling levels detected during the tests are recorded. The dominant mode of coupling appears to be caused by the diffusion of the magnetic fields through the system tunnel covers. The results from bond strap integrity testing showed that 16 of 18 bond straps survived. Design change evaluations showed that coupling reduction ranged from 0 to 36 decibels for each type of cable. The type of cable has less effect on coupling than does strike location and strike levels. Recommendations for design changes are made.

  14. Astronaut Joseph Kerwin strapped into sleep restraint in crew quarters

    NASA Image and Video Library

    1973-06-01

    Scientist-Astronaut Joseph P. Kerwin, Skylab 2 science pilot, is photographed strapped into the sleep restraint in the crew quarters of the Orbital Workshop of the Skylab 1 and 2 space station cluster in Earth orbit. Kerwin is wearing the special cap which contains biomedical instrumentation for the M133 Sleep Monitoring Experiment. The purpose of the M133 experiment is to evaluate quantity and quality of sleep during prolonged space flight by the analysis of electroencephalographic (EEG) and electrooculographic (EOG) activity.

  15. Lexan Linear Shaped Charge Holder with Magnets and Backing Plate

    NASA Technical Reports Server (NTRS)

    Maples, Matthew W.; Dutton, Maureen L.; Hacker, Scott C.; Dean, Richard J.; Kidd, Nicholas; Long, Chris; Hicks, Robert C.

    2013-01-01

    A method was developed for cutting a fabric structural member in an inflatable module, without damaging the internal structure of the module, using linear shaped charge. Lexan and magnets are used in a charge holder to precisely position the linear shaped charge over the desired cut area. Two types of charge holders have been designed, each with its own backing plate. One holder cuts fabric straps in the vertical configuration, and the other charge holder cuts fabric straps in the horizontal configuration.

  16. Inelastic behavior of cold-formed braced walls under monotonic and cyclic loading

    NASA Astrophysics Data System (ADS)

    Gerami, Mohsen; Lotfi, Mohsen; Nejat, Roya

    2015-06-01

    The ever-increasing need for housing generated the search for new and innovative building methods to increase speed and efficiency and enhance quality. One method is the use of light thin steel profiles as load-bearing elements having different solutions for interior and exterior cladding. Due to the increase in CFS construction in low-rise residential structures in the modern construction industry, there is an increased demand for performance inelastic analysis of CFS walls. In this study, the nonlinear behavior of cold-formed steel frames with various bracing arrangements including cross, chevron and k-shape straps was evaluated under cyclic and monotonic loading and using nonlinear finite element analysis methods. In total, 68 frames with different bracing arrangements and different ratios of dimensions were studied. Also, seismic parameters including resistance reduction factor, ductility and force reduction factor due to ductility were evaluated for all samples. On the other hand, the seismic response modification factor was calculated for these systems. It was concluded that the highest response modification factor would be obtained for walls with bilateral cross bracing systems with a value of 3.14. In all samples, on increasing the distance of straps from each other, shear strength increased and shear strength of the wall with bilateral bracing system was 60 % greater than that with lateral bracing system.

  17. Liking and wanting of drug and nondrug rewards in active cocaine users: the STRAP-R questionnaire

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Goldstein, R.Z.; Goldstein, R.Z.; Woicik, P.A..

    Few studies have examined the subjective value attributed to drug rewards specifically as it compares with the value attributed to primary non-drug rewards in addicted individuals. The objective of this study is to assess liking and wanting of expected drug rewards as compared to food and sex while respondents report about three different situations (current, and hypothetical in general, and under drug influence). In all, 20 cocaine-addicted individuals (mean abstinence = 2 days) and 20 healthy control subjects were administered the STRAP-R (Sensitivity To Reinforcement of Addictive and other Primary Rewards) questionnaire after receiving an oral dose of the dopaminemore » agonist methylphenidate (20 mg) or placebo. The reinforcers relative value changed within the addicted sample when reporting about the under drug influence situation (drug > food; otherwise, drug < food). This change was highest in the addicted individuals with the youngest age of cocaine use onset. Moreover, drug wanting exceeded drug liking in the addicted subjects when reporting about this situation during methylphenidate. Thus, cocaine-addicted individuals assign the highest subjective valence to drug rewards but only when recalling cue-related situations. When recalling this situation, they also report higher drug wanting than hedonic liking, a motivational shift that was only significant during methylphenidate. Together, these valence shifts may underlie compulsive stimulant abuse upon pharmacological or behavioural cue exposure in addicted individuals. Additional studies are required to assess the reliability of the STRAP-R in larger samples and to examine its validity in measuring the subjective value attributed to experienced reinforcers or in predicting behaviour.« less

  18. Structural health monitoring of Lindquist bridge

    NASA Astrophysics Data System (ADS)

    Sargent, D. D.; Murison, E. R.; Bakht, B.; Mufti, A. A.

    2007-04-01

    Many forestry bridges in Canada are typically single-lane, single span structures with two steel plate girders and a deck comprising of precast reinforced concrete panels. The concept of arching in deck slabs was utilized in the steel-free precast panels used in the Lindquist Bridge in British Columbia, Canada. The panels were completely devoid of tensile reinforcement and transverse confinement to the panels was provided by external steel straps. After the bridge was constructed in 1998, electrical strain gauges were installed on the girders and straps. Static and dynamic load tests were performed. The cracks on the top and bottom of the deck were mapped in 1999 and 2003. In 2006, a load test and crack mapping were performed on the bridge. The strain readings in the straps were compared with the data obtained 8 years prior. After analysis of the strain gauge readings, conclusions were drawn on the performance of the bridge. The cracks were formed to accommodate arching action and it was concluded that the bridge is still performing as it was designed.

  19. Flexible piezoelectric energy harvesting from jaw movements

    NASA Astrophysics Data System (ADS)

    Delnavaz, Aidin; Voix, Jérémie

    2014-10-01

    Piezoelectric fiber composites (PFC) represent an interesting subset of smart materials that can function as sensor, actuator and energy converter. Despite their excellent potential for energy harvesting, very few PFC mechanisms have been developed to capture the human body power and convert it into an electric current to power wearable electronic devices. This paper provides a proof of concept for a head-mounted device with a PFC chin strap capable of harvesting energy from jaw movements. An electromechanical model based on the bond graph method is developed to predict the power output of the energy harvesting system. The optimum resistance value of the load and the best stretch ratio in the strap are also determined. A prototype was developed and tested and its performances were compared to the analytical model predictions. The proposed piezoelectric strap mechanism can be added to all types of head-mounted devices to power small-scale electronic devices such as hearing aids, electronic hearing protectors and communication earpieces.

  20. Thermo-electric modular structure and method of making same

    DOEpatents

    Freedman, N.S.; Horsting, C.W.; Lawrence, W.F.; Carrona, J.J.

    1974-01-29

    A method is presented for making a thermoelectric module wtth the aid of an insulating wafer having opposite metallized surfaces, a pair of similar equalizing sheets of metal, a hot-junction strap of metal, a thermoelectric element having hot- and cold-junction surfaces, and a radiator sheet of metal. The method comprises the following steps: brazing said equalizer sheets to said opposite metallized surfaces, respectively, of said insulating wafer with pure copper in a non-oxidizing ambient; brazing one surface of said hot-junction strap to one of the surfaces of said equalizing sheet with a nickel-gold alloy in a non- oxidizing ambient; and diffusion bonding said hot-junction surface of said thermoelectric element to the other surface of said hot-junction strap and said radiator sheet to said cold-junction surface of said thermoelectric element, said diffusion bonding being carried out in a non-oxidizing ambient, under compressive loading, at a temperature of about 550 deg C., and for about one-half hour. (Official Gazette)

  1. Effect of toe extension on EMG of triceps surae muscles during isometric dorsiflexion.

    PubMed

    Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh

    2016-12-01

    The protocol for estimating force of contraction by triceps surae (TS) muscles requires the immobilization of the ankle during dorsiflexion and plantar flexion. However, large variability in the results has been observed. To identify the cause of this variability, experiments were conducted where ankle dorsiflexion force and electromyogram (EMG) of the TS were recorded under two conditions: (i) toes were strapped and (ii) toes were unstrapped, with all other conditions such as immobilization of the ankle remaining unchanged. The root mean square (RMS) of the EMG and the force were analyzed and one-tail Student's t-test was performed for significance between the two conditions. The RMS of the EMG from TS muscles was found to be significantly higher (~55%) during dorsiflexion with toes unstrapped compared with when the toes were strapped. The torque corresponding to dorsiflexion was also higher with toes unstrapped. Our study has shown that it is important to strap the toes when measuring the torque at the ankle and EMG of the TS muscles.

  2. Improvement of isometric dorsiflexion protocol for assessment of tibialis anterior muscle strength.

    PubMed

    Siddiqi, Ariba; Arjunan, Sridhar P; Kumar, Dinesh

    2015-01-01

    It is important to accurately estimate the electromyogram (EMG)/force relationship of triceps surae (TS) muscle for detecting strength deficit of tibalis anterior (TA) muscle. In literature, the protocol for recording EMG and force of dorsiflexion have been described, and the necessity for immobilizing the ankle has been explained. However, there is a significant variability of the results among researchers even though they report the fixation of the ankle. We have determined that toe extension can cause significant variation in the dorsiflexion force and EMG of TS and this can occur despite following the current guidelines which require immobilizing the ankle. The results also show that there was a large increase in the variability of the force and the RMS of EMG of TS when the toes were not strapped compared with when they were strapped. Thus, with the current guidelines, where there are no instructions regarding the necessity of strapping the toes, the EMG/force relationship of TS could be incorrect and give an inaccurate assessment of the dorsiflexor TA strength. In summary, •Current methodology to estimate the dorsiflexor TA strength with respect to the TS activity, emphasizing on ankle immobilization is insufficient to prevent large variability in the measurements.•Toe extension during dorsiflexion was found to be one source of variability in estimating the TA strength.•It is recommended that guidelines for recording force and EMG from TA and TS muscles should require the strapping of the toes along with the need for immobilizing the ankle.

  3. Direct measurement of fast transients by using boot-strapped waveform averaging

    NASA Astrophysics Data System (ADS)

    Olsson, Mattias; Edman, Fredrik; Karki, Khadga Jung

    2018-03-01

    An approximation to coherent sampling, also known as boot-strapped waveform averaging, is presented. The method uses digital cavities to determine the condition for coherent sampling. It can be used to increase the effective sampling rate of a repetitive signal and the signal to noise ratio simultaneously. The method is demonstrated by using it to directly measure the fluorescence lifetime from Rhodamine 6G by digitizing the signal from a fast avalanche photodiode. The obtained lifetime of 4.0 ns is in agreement with the known values.

  4. Analyzing bean extracts using time-dependent SDS trapping to quantify the kinetic stability of phaseolin proteins.

    PubMed

    Thibeault, Jane; Church, Jennifer; Ortiz-Perez, Brian; Addo, Samuel; Hill, Shakeema; Khalil, Areeg; Young, Malaney; Xia, Ke; Colón, Wilfredo

    2017-09-30

    In common beans and lima bean, the storage protein phaseolin is difficult to degrade and SDS-resistant, a sign of kinetic stability. Kinetically stable proteins (KSPs) are characterized by having a high-energy barrier between the native and denatured states that results in very slow unfolding. Such proteins are resistant to proteolytic degradation and detergents, such as SDS. Here the method SDS-Trapping of Proteins (S-TraP) is applied directly on bean extracts to quantify the kinetic stability of phaseolin in lima bean and several common beans, including black bean, navy bean, and small red bean. The bean extracts were incubated in SDS at various temperatures (60-75 °C) for different time periods, followed by SDS-PAGE analysis at room temperature, and subsequent band quantification to determine the kinetics of phaseolin unfolding. Eyring plot analysis showed that the phaseolin from each bean has high kinetic stability, with an SDS-trapping (i.e. unfolding) half-life ranging from about 20-100 years at 24 °C and 2-7 years at 37 °C. The remarkably high kinetic stability of these phaseolin proteins is consistent with the low digestibility of common beans and lima bean, as well as their relatively high germination temperatures. From a practical perspective, this work exemplifies that S-TraP is a useful and cost-effective method for quantifying the kinetic stability of proteins in biological extracts or lysates. Depending on the protein to be studied and its abundance, S-TraP may be performed directly on the extract without need for protein purification. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Improvement of isometric dorsiflexion protocol for assessment of tibialis anterior muscle strength☆

    PubMed Central

    Siddiqi, Ariba; Arjunan, Sridhar P.; Kumar, Dinesh

    2015-01-01

    It is important to accurately estimate the electromyogram (EMG)/force relationship of triceps surae (TS) muscle for detecting strength deficit of tibalis anterior (TA) muscle. In literature, the protocol for recording EMG and force of dorsiflexion have been described, and the necessity for immobilizing the ankle has been explained. However, there is a significant variability of the results among researchers even though they report the fixation of the ankle. We have determined that toe extension can cause significant variation in the dorsiflexion force and EMG of TS and this can occur despite following the current guidelines which require immobilizing the ankle. The results also show that there was a large increase in the variability of the force and the RMS of EMG of TS when the toes were not strapped compared with when they were strapped. Thus, with the current guidelines, where there are no instructions regarding the necessity of strapping the toes, the EMG/force relationship of TS could be incorrect and give an inaccurate assessment of the dorsiflexor TA strength. In summary, • Current methodology to estimate the dorsiflexor TA strength with respect to the TS activity, emphasizing on ankle immobilization is insufficient to prevent large variability in the measurements. • Toe extension during dorsiflexion was found to be one source of variability in estimating the TA strength. • It is recommended that guidelines for recording force and EMG from TA and TS muscles should require the strapping of the toes along with the need for immobilizing the ankle. PMID:26150978

  6. Battery thermal management unit

    NASA Astrophysics Data System (ADS)

    Sanders, Nicholas A.

    1989-03-01

    A battery warming device has been designed which uses waste heat from an operating internal combustion engine to warm a battery. A portion of the waste heat is stored in the sensible and latent heat of a phase change type material for use in maintaining the battery temperature after the engine is shut off. The basic design of the device consists of a Phase Change Material (PCM) reservoir and a simple heat exchanger connected to the engineer's cooling system. Two types of units were built, tested and field trialed. A strap-on type which was strapped to the side of an automotive battery and was intended for the automotive after-market and a tray type on which a battery or batteries sat. This unit was intended for the heavy duty truck market. It was determined that both types of units increased the average cranking power of the batteries they were applied to. Although there were several design problems with the units such as the need for an automatic thermostatically controlled bypass valve, the overall feeling is that there is a market opportunity for both the strap-on and tray type battery warming units.

  7. Upgrades to the NSTX HHFW antenna

    NASA Astrophysics Data System (ADS)

    Ellis, R.; Brunkhorst, C.; Hosea, J.

    2014-02-01

    The High Harmonic Fast Wave (HHFW) antenna for the National Spherical Torus Experiment (NSTX) at PPPL will be upgraded as part of the NSTX upgrade project. Higher magnetic fields and plasma current result in disruption forces on the current straps that can be up to four times the original design values. The current straps on the HHFW antenna are presently fed by coaxial feedthroughs with rigid center conductors. The additional forces on the current straps require a compliant section in the center conductor in order to minimize the forces on the feedthrough. The design of this compliant section has been an integrated effort involving electrostatic calculations in parallel with mechanical and thermal analyses, in order to arrive at a design that is optimized for mechanical, thermal and electrical considerations. The voltage standoff obtained from this design will be verified when a prototype antenna is evaluated on our RF test stand. This paper describes the design of the compliant section of the center conductor, mechanical, thermal and electrostatic calculations, and plans for full implementation of the upgrade on NSTX.

  8. ATTITUDE OF CLEFT CARE SPECIALISTS IN AFRICA TOWARDS PRESURGICAL ORTHOPAEDICS.

    PubMed

    Adeyemi, A T; Bankole, O O

    2012-12-01

    To determine the attitude of cleft care specialists working in Africa towards pre-surgical orthopaedics. A cross sectional study. Pan-African conference on cleft lip and palate in Nigeria. Sixty cleft care specialists working in Africa. The general attitude towards pre-surgicalorthopaedics was positive. Majority of the specialists employ pre-surgical orthopaedics before surgical repair. Fifty four (91%) of the specialists use plaster strapping for cases of bilateral cleft, five (8.3%) use nasoalveolar molding and one (2%) use feeding plate. Half of the specialists (50%) felt that pre-surgical orthopaedics is to be managed by orthodontists alone. There were significant difference in attitude towards pre-surgical orthopaedics between providers (p < 0.05). Orthodontists had a strong positive attitude towards pre-surgical orthopaedics than other specialists. Younger specialists had a more positive attitude towards pre-surgical orthopaedics than older specialists. Cleft care specialists in Africa have a positive attitude towards pre-surgical orthopaedics. Majority of them use plaster strapping technique. Younger specialists have a more favorable attitude towards pre-surgical orthopaedics than older specialists.

  9. Quantifying the human-robot interaction forces between a lower limb exoskeleton and healthy users.

    PubMed

    Rathore, Ashish; Wilcox, Matthew; Ramirez, Dafne Zuleima Morgado; Loureiro, Rui; Carlson, Tom

    2016-08-01

    To counter the many disadvantages of prolonged wheelchair use, patients with spinal cord injuries (SCI) are beginning to turn towards robotic exoskeletons. However, we are currently unaware of the magnitude and distribution of forces acting between the user and the exoskeleton. This is a critical issue, as SCI patients have an increased susceptibility to skin lesions and pressure ulcer development. Therefore, we developed a real-time force measuring apparatus, which was placed at the physical human-robot interface (pHRI) of a lower limb robotic exoskeleton. Experiments captured the dynamics of these interaction forces whilst the participants performed a range of typical stepping actions. Our results indicate that peak forces occurred at the anterior aspect of both the left and right legs, areas that are particularly prone to pressure ulcer development. A significant difference was also found between the average force experienced at the anterior and posterior sensors of the right thigh during the swing phase for different movement primitives. These results call for the integration of instrumented straps as standard in lower limb exoskeletons. They also highlight the potential of such straps to be used as an alternative/complementary interface for the high-level control of lower limb exoskeletons in some patient groups.

  10. A Distance Detector with a Strip Magnetic MOSFET and Readout Circuit.

    PubMed

    Sung, Guo-Ming; Lin, Wen-Sheng; Wang, Hsing-Kuang

    2017-01-10

    This paper presents a distance detector composed of two separated metal-oxide semiconductor field-effect transistors (MOSFETs), a differential polysilicon cross-shaped Hall plate (CSHP), and a readout circuit. The distance detector was fabricated using 0.18 μm 1P6M Complementary Metal-Oxide Semiconductor (CMOS) technology to sense the magnetic induction perpendicular to the chip surface. The differential polysilicon CSHP enabled the magnetic device to not only increase the magnetosensitivity but also eliminate the offset voltage generated because of device mismatch and Lorentz force. Two MOSFETs generated two drain currents with a quadratic function of the differential Hall voltages at CSHP. A readout circuit-composed of a current-to-voltage converter, a low-pass filter, and a difference amplifier-was designed to amplify the current difference between two drains of MOSFETs. Measurements revealed that the electrostatic discharge (ESD) could be eliminated from the distance sensor by grounding it to earth; however, the sensor could be desensitized by ESD in the absence of grounding. The magnetic influence can be ignored if the magnetic body (human) stays far from the magnetic sensor, and the measuring system is grounded to earth by using the ESD wrist strap (Strap E-GND). Both 'no grounding' and 'grounding to power supply' conditions were unsuitable for measuring the induced Hall voltage.

  11. Residual Strength Prediction of Fuselage Structures with Multiple Site Damage

    NASA Technical Reports Server (NTRS)

    Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.

    1999-01-01

    This paper summarizes recent results on simulating full-scale pressure tests of wide body, lap-jointed fuselage panels with multiple site damage (MSD). The crack tip opening angle (CTOA) fracture criterion and the FRANC3D/STAGS software program were used to analyze stable crack growth under conditions of general yielding. The link-up of multiple cracks and residual strength of damaged structures were predicted. Elastic-plastic finite element analysis based on the von Mises yield criterion and incremental flow theory with small strain assumption was used. A global-local modeling procedure was employed in the numerical analyses. Stress distributions from the numerical simulations are compared with strain gage measurements. Analysis results show that accurate representation of the load transfer through the rivets is crucial for the model to predict the stress distribution accurately. Predicted crack growth and residual strength are compared with test data. Observed and predicted results both indicate that the occurrence of small MSD cracks substantially reduces the residual strength. Modeling fatigue closure is essential to capture the fracture behavior during the early stable crack growth. Breakage of a tear strap can have a major influence on residual strength prediction.

  12. Design of a developmental dual fail operational redundant strapped down inertial measurement unit

    NASA Technical Reports Server (NTRS)

    Morrell, F. R.; Russell, J. G.

    1980-01-01

    An experimental redundant strap-down inertial measurement unit (RSDIMU) is being developed at NASA-Langley as a link to satisfy safety and reliability considerations in the integrated avionics concept. The unit consists of four two-degrees-of-freedom (TDOF) tuned-rotor gyros, and four TDOF pendulous accelerometers in a skewed and separable semi-octahedron array. The system will be used to examine failure detection and isolation techniques, redundancy management rules, and optimal threshold levels for various flight configurations. The major characteristics of the RSDIMU hardware and software design, and its use as a research tool are described.

  13. Human Tolerance to Rapidly Applied Accelerations: A Summary of the Literature

    NASA Technical Reports Server (NTRS)

    Eiband, A. Martin

    1959-01-01

    The literature is surveyed to determine human tolerance to rapidly applied accelerations. Pertinent human and animal experiments applicable to space flight and to crash impact forces are analyzed and discussed. These data are compared and presented on the basis of a trapezoidal pulse. The effects of body restraint and of acceleration direction, onset rate, and plateau duration on the maximum tolerable and survivable rapidly applied accelerations are shown. Results of the survey indicate that adequate torso and extremity restraint is the primary variable in tolerance to rapidly applied accelerations. The harness, or restraint system, must be arranged to transmit the major portion of the accelerating force directly to the pelvic structure and not via the vertebral column. When the conditions of adequate restraint have been met, then the other variables, direction, magnitude, and onset rate of rapidly applied accelerations, govern maximum tolerance and injury limits. The results also indicate that adequately stressed aft-faced passenger seats offer maximum complete body support with minimum objectionable harnessing. Such a seat, whether designed for 20-, 30-, or 40-G dynamic loading, would include lap strap, chest (axillary) strap, and winged-back seat to increase headward and lateral G protection, full-height integral head rest, arm rests (load-bearing) with recessed hand-holds and provisions to prevent arms from slipping either laterally or beyond the seat back, and leg support to keep the legs from being wedged under the seat. For crew members and others whose duties require forward-facing seats, maximum complete body support requires lap, shoulder, and thigh straps, lap-belt tie-down strap, and full-height seat back with integral head support.

  14. Regional differences in hyoid muscle activity and length-dynamics during mammalian head-shaking

    PubMed Central

    Wentzel, Sarah E.; Konow, Nicolai; German, Rebecca Z.

    2010-01-01

    The sternohyoid (SH) and geniohyoid (GH) are antagonist strap-muscles that are active during a number of different behaviors, including sucking, intraoral transport, swallowing, breathing, and extension/flexion of the neck. Because these muscles have served different functions through the evolutionary history of vertebrates, it is quite likely they will have complex patterns of electrical activity and muscle fiber contraction. Different regions of the sternohyoid exhibit different contraction and activity patterns during a swallow. We examined the dynamics of the sternohyoid and geniohyoid muscles during an unrestrained, and vigorous head-shake behavior in an animal model of human head, neck and hyolingual movement. A gentle touch to infant pig ears elicited a head shake of several head revolutions. Using sonomicrometry and intramuscular EMG we measured regional (within) muscle strain and activity in SH and GH. We found that EMG was consistent across three regions (anterior, belly and posterior) of each muscle. Changes in muscle length however, were more complex. In the SH, mid-belly length-change occurred out of phase with the anterior and posterior end-regions, but with a zero-lag timing; the anterior region shortened prior to the posterior. In the GH, the anterior region shortened prior to, and out of phase with the mid-belly and posterior regions. Head-shaking is a relatively simple reflex behavior, yet the underlying patterns of muscle length-dynamics and EMG activity are not. The regional complexity in SH and GH, similar to regionalization of SH during swallowing, suggests that these ‘simple hyoid strap muscles’ are more complex than textbooks often suggest. PMID:21370479

  15. The Delta launch vehicle Model 2914 series

    NASA Technical Reports Server (NTRS)

    Gunn, C. R.

    1973-01-01

    Description of a new, medium-class Delta launch-vehicle configuration, the three-stage Model 2914. The first stage of this vehicle is composed of a liquid-propellant core which is thrust-augmented with up to nine strap-on solid-propellant motors. The second stage, recently uprated with a strap-down inertial guidance system, is now being modified to adapt the liquid-propellant descent engine from the Apollo Lunar Excursion Module. The third stage is a spin-stabilized solid-propellant motor. The Model 2914 is capable of injecting 2040 kg into low earth orbit, 705 kg into geosynchronous transfer orbit, or 455 kg into an escape trajectory.

  16. Axial crack propagation and arrest in pressurized fuselage

    NASA Technical Reports Server (NTRS)

    Kosai, M.; Shimamoto, A.; Yu, C.-T.; Walker, S. I.; Kobayashi, A. S.; Tan, P.

    1994-01-01

    The crack arrest capability of a tear strap in a pressurized precracked fuselage was studied through instrumented axial rupture tests of small scale models of an idealized fuselage. Upon pressurization, rapid crack propagation initiated at an axial through crack along the stringer and immediately kinked due to the mixed modes 1 and 2 state caused by the one-sided opening of the crack flap. The diagonally running crack further turned at the tear straps. Dynamic finite element analysis of the rupturing cylinder showed that the crack kinked and also ran straight in the presence of a mixed mode state according to a modified two-parameter crack kinking criterion.

  17. Thermal resilient multiple jaw braze fixture

    DOEpatents

    Ney, Robert; Perrone, Alex J.

    1995-07-11

    A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle.

  18. ICRF operation with improved antennas in ASDEX Upgrade with W wall

    NASA Astrophysics Data System (ADS)

    Bobkov, V.; Balden, M.; Bilato, R.; Braun, F.; Dux, R.; Herrmann, A.; Faugel, H.; Fünfgelder, H.; Giannone, L.; Kallenbach, A.; Maier, H.; Müller, H. W.; Neu, R.; Noterdaeme, J.-M.; Pütterich, Th.; Rohde, V.; Tsujii, N.; Zeus, F.; Zohm, H.; the ASDEX Upgrade Team

    2013-09-01

    Experiments with boron-coated side limiters of two antennas operated together in 2012 showed that the side limiters are responsible for more than half of the increased W content in the plasma. Together with the contribution from the other limiter tiles, not replaced in 2012, the limiters account for at least two thirds of the W content. A modified test two-strap ion cyclotron range of frequency (ICRF) antennas in ASDEX Upgrade with broad limiters and narrow straps has shown an improved operation with full W wall in 2011/2012 campaigns with up to a 40% lower rise of W concentration allowing more stable operation at low deuterium gas injection rate. Limiter spectroscopy measurements indicate up to a 40% reduction of the rise of the W sputtering yield during ICRF power, measured under the assumption of negligible influence of geometry variations and reflections on the measurements. The boron limiters on two antennas together with the improved broad-limiter antenna allowed a successful ICRF operation in 2012. As a part of long-term strategy of antenna design development, two three-strap antennas with phase and power balance control for reduction of E‖ are planned for installation in the future.

  19. Use of a forensic technique to identify blood contamination of emergency department and ambulance trauma equipment.

    PubMed

    Lee, J B; Levy, M; Walker, A

    2006-01-01

    Using a Kastle-Meyer (KM) technique, the following equipment from the emergency departments of six UK hospitals (four trusts) and three regional ambulance services was tested for blood contamination: extrication ("spinal") boards, cervical collars, straps, box splints, head blocks, and headboards. Only equipment ready for patient use was tested. Over half of trauma equipment (57%) tested positive for blood, including 15% of equipment that was visibly stained with blood. There have been no recorded cases of infection from contaminated trauma equipment but our study has identified the potential risk. Disposable covers for boards, disposable straps, and disposable radiolucent head blocks which are currently available provide a solution but have resource implications.

  20. Multi-Axis Test Facility Orientation

    NASA Image and Video Library

    1960-03-01

    Seven Astronauts and William North undergo Multi Axis Space Test Inertia Facility (MASTIF) orientation: This film contains footage Gus Grissom leaving "Astro-Penthouse" and beginning tests, pilot Joe Algranti explaining the MASTIF to Scott Carpenter, Walter Schirra testing the controls and being strapped in, Deke Slayton climbing into the rig, and John Glenn preparing for test and being briefed by Algranti. Also seen are Alan Shepherd talking with Algranti and James Useller prior to climbing into rig and beginning test, Gordon Cooper being strapped in and beginning his test, Cooper and Algranti briefing to William North prior to his test. North was a test pilot on the NASA committee which selected the Mercury 7 astronauts.

  1. Thermal resilient multiple jaw braze fixture

    DOEpatents

    Ney, R.; Perrone, A.J.

    1995-07-11

    A braze fixture has side walls forming a cavity with an opening to receive a stack of parts to be brazed. Sidewalls of the housing have a plurality of bearing receiving openings into which bearing rods or jaws are inserted to align the stacked elements of the workpiece. The housing can also have view ports to allow a visual check of the alignment. Straps or wires around the fixture are selected to have thermal characteristics similar to the thermal characteristics of the workpiece undergoing brazing. The straps or wires make physical contact with the bearing rods thereby causing bearing rods to maintain the workpiece in proper alignment throughout the entire brazing cycle. 9 figs.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bucholtz, A.; Bluth, R.; Pfaff, B.

    Measurements of solar and infrared irradiance by instruments rigidly mounted to an aircraft have historically been plagued by the introduction of offsets and fluctuations into the data that are solely due to the pitch and roll movements of the aircraft. Two STabilized RAdiometer Platforms (STRAPs) were developed for the U.S. Navy in the early to mid-2000s to address this problem. The development was a collaborative effort between the Naval Research Laboratory (NRL), the Naval Postgraduate School Center for Interdisciplinary Remotely Piloted Aircraft Studies (CIRPAS), and the U.S. Department of Energy (DOE) Sandia National Laboratories. The STRAPs were designed and builtmore » by L-3 Communications Sonoma EO (formerly the small business Sonoma Design Group).« less

  3. Urine cup for collection of urine from cows.

    PubMed

    Fellner, V; Weiss, M F; Belo, A T; Belyea, R L; Martz, F A; Orma, A H

    1988-08-01

    A urine cup for continuous and complete collection of urine from cows was constructed from Plastisol, cotton webb strapping, Velcro Brand touch fasteners [corrected], snap-fasteners, denim patches, weather stripping, and vacuum hose. The urine cup was made from Plastisol using a heated lead mold. It was large enough to enclose a 9 cm x 6 cm area around the vulva of a cow and was attached by strapping and Velcro Brand touch fasteners [corrected] to patches glued to the rump. Urine cups were used repeatedly and provided for long-term collection of urine from cows, eliminating the need for indwelling catheters. Applications include long-term nutrient balance, radioisotope, and metabolism studies.

  4. Use of a Novel Abdominal Aortic and Junctional Tourniquet to Reduce or Eliminate Flow in the Brachial and Popliteal Arteries in Human Subjects.

    PubMed

    Lyon, Matthew; Johnson, Daniel; Gordon, Richard

    2015-01-01

    Penetrating injuries of the proximal large arteries are a common cause of death on the battlefield due to rapid exsanguination. Applying an effective tourniquet to stop bleeding at the axillary and proximal femoral arteries (junctional sites) is difficult. Prior studies have shown that the Abdominal Aortic and Junctional Tourniquet (AAJT) effectively reduced blood flow in the common femoral artery with application of the device around the lower abdomen. Our objective was to determine the effectiveness of the AAJT to stop blood flow in the proximal femoral artery (PFA), and the axillary artery (AA). This was a prospective observational trial using human volunteers. The AAJT consists of a wedge-shaped bladder and integrated strap. The bladder has an integrated manometer, which is used to measure the pressure in the bladder. For the AA, the AAJT was placed over the axillary junction at the anterior axillary line with the strap placed across the contralateral shoulder. For the PFA, the AAJT bladder was placed over the right groin with the strap positioned across both femoral trochanters. Spectral Doppler measurements were taken of the PFA and AA at baseline and as the bladder was inflated. Collected data included pressure of the AAJT.

  5. Cardiorespiratory effects of inelastic chest wall restriction.

    PubMed

    Miller, Jordan D; Beck, Kenneth C; Joyner, Michael J; Brice, A Glenn; Johnson, Bruce D

    2002-06-01

    We examined the effects of chest wall restriction (CWR) on cardiorespiratory function at rest and during exercise in healthy subjects in an attempt to approximate the cardiorespiratory interactions observed in clinical conditions that result in restrictive lung and/or chest wall changes and a reduced intrathoracic space. Canvas straps were applied around the thorax and abdomen so that vital capacity was reduced by >35%. Data were acquired at rest and during cycle ergometry at 25 and 45% of peak workloads. CWR elicited significant increases in the flow-resistive work performed on the lung (160%) and the gastric pressure-time integral (>400%) at the higher workload, but it resulted in a decrease in the elastic work performed on the lung (56%) compared with control conditions. With CWR, heart rate increased and stroke volume (SV) fell, resulting in >10% fall in cardiac output at rest and during exercise at matched workloads (P < 0.05). Blood pressure and catecholamines were significantly elevated during CWR exercise conditions (P < 0.05). We conclude that CWR significantly impairs SV during exercise and that a compensatory increase in heart rate does not prevent a significant reduction in cardiac output. O(2) consumption appears to be maintained via increased extraction and a redistribution of blood flow via sympathetic activation.

  6. Crack Growth Simulation and Residual Strength Prediction in Airplane Fuselages

    NASA Technical Reports Server (NTRS)

    Chen, Chuin-Shan; Wawrzynek, Paul A.; Ingraffea, Anthony R.

    1999-01-01

    The objectives were to create a capability to simulate curvilinear crack growth and ductile tearing in aircraft fuselages subjected to widespread fatigue damage and to validate with tests. Analysis methodology and software program (FRANC3D/STAGS) developed herein allows engineers to maintain aging aircraft economically, while insuring continuous airworthiness, and to design more damage-tolerant aircraft for the next generation. Simulations of crack growth in fuselages were described. The crack tip opening angle (CTOA) fracture criterion, obtained from laboratory tests, was used to predict fracture behavior of fuselage panel tests. Geometrically nonlinear, elastic-plastic, thin shell finite element crack growth analyses were conducted. Comparisons of stress distributions, multiple stable crack growth history, and residual strength between measured and predicted results were made to assess the validity of the methodology. Incorporation of residual plastic deformations and tear strap failure was essential for accurate residual strength predictions. Issue related to predicting crack trajectory in fuselages were also discussed. A directional criterion, including T-stress and fracture toughness orthotropy, was developed. Curvilinear crack growth was simulated in coupon and fuselage panel tests. Both T-stress and fracture toughness orthotropy were essential to predict the observed crack paths. Flapping of fuselages were predicted. Measured and predicted results agreed reasonable well.

  7. Prediction of Launch Vehicle Ignition Overpressure and Liftoff Acoustics

    NASA Technical Reports Server (NTRS)

    Casiano, Matthew

    2009-01-01

    The LAIOP (Launch Vehicle Ignition Overpressure and Liftoff Acoustic Environments) program predicts the external pressure environment generated during liftoff for a large variety of rocket types. These environments include ignition overpressure, produced by the rapid acceleration of exhaust gases during rocket-engine start transient, and launch acoustics, produced by turbulence in the rocket plume. The ignition overpressure predictions are time-based, and the launch acoustic predictions are frequency-based. Additionally, the software can predict ignition overpressure mitigation, using water-spray injection into the rocket exhaust stream, for a limited number of configurations. The framework developed for these predictions is extensive, though some options require additional relevant data and development time. Once these options are enabled, the already extensively capable code will be further enhanced. The rockets, or launch vehicles, can either be elliptically or cylindrically shaped, and up to eight strap-on structures (boosters or tanks) are allowed. Up to four engines are allowed for the core launch vehicle, which can be of two different types. Also, two different sizes of strap-on structures can be used, and two different types of booster engines are allowed. Both tabular and graphical presentations of the predicted environments at the selected locations can be reviewed by the user. The output includes summaries of rocket-engine operation, ignition overpressure time histories, and one-third octave sound pressure spectra of the predicted launch acoustics. Also, documentation is available to the user to help him or her understand the various aspects of the graphical user interface and the required input parameters.

  8. Around Marshall

    NASA Image and Video Library

    1976-08-18

    A metal strap became tangled over one of the folded solar array panels when Skylab lost its micro meteoroid shield during its launch. Cutters like the ones used to free the solar array were used to cut the ribbon opening to the public a new full-scale Skylab cluster exhibit at the Alabama Space and Rocket Center in Huntsville, Alabama. Wielding the cutters are (left to right): Alabama Senator James B. Allen; Marshall Space Flight Center director, Dr. William R. Lucas, Huntsville Mayor, Joe Davis; Madison County Commission Chairman, James Record (standing behind Mayor Davis); and chairman of the Alabama Space Science Exhibit Commission, Jack Giles. Astronauts Conrad and Kerwin used the same type of tool in Earth orbit to cut the aluminum strap which jammed the Skylab solar array.

  9. Bipyrrole-Strapped Calix[4]pyrroles: Strong Anion Receptors That Extract the Sulfate Anion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Sung Kuk; Lee, Juhoon; Williams, Neil J

    Cage-type calix[4]pyrroles 2 and 3 bearing two additional pyrrole groups on the strap have been synthesized. Compared with the parent calix[4]pyrrole (1), they were found to exhibit remarkably enhanced affinities for anions, including the sulfate anion (TBA+ salts), in organic media (CD2Cl2). This increase is ascribed to participation of the bipyrrole units in anion binding. Receptors 2 and 3 extract the hydrophilic sulfate anion (as the methyltrialkyl(C8-10)ammonium (A336+) salt)) from aqueous media into a chloroform phase with significantly improved efficiency (>10-fold relative to calix[4]pyrrole 1). These two receptors also solubilize into chloroform the otherwise insoluble sulfate salt, (TMA)2SO4 (tetramethylammonium sulfate).

  10. Inorganic spark chamber frame and method of making the same

    NASA Technical Reports Server (NTRS)

    Heslin, T. M. (Inventor)

    1982-01-01

    A spark chamber frame, manufactured using only inorganic materials is described. The spark chamber frame includes a plurality of beams formed from inorganic material, such as ceramic or glass, and are connected together at ends with inorganic bonding material having substantially the same thermal expansion as the beam material. A plurality of wires formed from an inorganic composition are positioned between opposed beams so that the wires are uniformly spaced and form a grid. A plurality of hold down straps are formed of inorganic material such as ceramic or glass having substantially the same chemical and thermal properties as the beam material. Hold down straps overlie wires extending over the beams and are bonded thereto with inorganic bonding material.

  11. Use of a forensic technique to identify blood contamination of emergency department and ambulance trauma equipment

    PubMed Central

    Lee, J B; Levy, M; Walker, A

    2006-01-01

    Using a Kastle‐Meyer (KM) technique, the following equipment from the emergency departments of six UK hospitals (four trusts) and three regional ambulance services was tested for blood contamination: extrication (“spinal”) boards, cervical collars, straps, box splints, head blocks, and headboards. Only equipment ready for patient use was tested. Over half of trauma equipment (57%) tested positive for blood, including 15% of equipment that was visibly stained with blood. There have been no recorded cases of infection from contaminated trauma equipment but our study has identified the potential risk. Disposable covers for boards, disposable straps, and disposable radiolucent head blocks which are currently available provide a solution but have resource implications PMID:16373813

  12. Pyrrole- and Naphthobipyrrole-Strapped Calix[4]pyrroles as Azide Anion Receptors.

    PubMed

    Kim, Seung Hyeon; Lee, Juhoon; Vargas-Zúñiga, Gabriela I; Lynch, Vincent M; Hay, Benjamin P; Sessler, Jonathan L; Kim, Sung Kuk

    2018-03-02

    The binding interactions between the azide anion (N 3 - ) and the strapped calix[4]pyrroles 2 and 3 bearing auxiliary hydrogen bonding donors on the bridging moieties, as well as of normal calix[4]pyrrole 1, were investigated via 1 H NMR spectroscopic and isothermal titration calorimetry analyses. The resulting data revealed that receptors 2 and 3 have significantly higher affinities for the azide anion in organic media as compared with the unfunctionalized calix[4]pyrrole 1 and other azide receptors reported to date. Single crystal X-ray diffraction analyses and calculations using density functional theory revealed that receptor 2 binds CsN 3 in two distinct structural forms. As judged from the metric parameters, in the resulting complexes one limiting azide anion resonance contributor is favored over the other, with the specifics depending on the binding mode. In contrast to what is seen for 2, receptor 3 forms a CsN 3 complex in 20% CD 3 OD in CDCl 3 , wherein the azide anion is bound only vertically to the NH protons of the calix[4]pyrrole and the cesium cation is complexed within the cone shaped-calix[4]pyrrole bowl. The bound cesium cation is also in close proximity to a naphthobipyrrole subunit present in a different molecule, forming an apparent cation-π complex.

  13. Effect of sports bra type and gait speed on breast discomfort, bra discomfort and perceived breast movement in Chinese women.

    PubMed

    Chen, Xiaona; Gho, Sheridan A; Wang, Jianping; Steele, Julie R

    2016-01-01

    This study investigated the effect of sports bra type (encapsulation versus compression) and gait speed on perceptions of breast discomfort, bra discomfort and breast movement reported by Chinese women. Visual analogue scales were used to evaluate breast discomfort, bra component discomfort and perceived breast movement of 21 Chinese participants when they wore an encapsulation or a compression sports bra, while static and while exercising at three different gait speeds. Participants perceived less breast discomfort and breast movement when wearing a compression bra compared to an encapsulation bra at a high gait speed, suggesting that compression bras are likely to provide the most effective support for Chinese women. However, significantly higher bra discomfort was perceived in the compression bra compared to the encapsulation bra when static and at the lower gait speed, implying that ways to modify the design of sports bras, particularly the straps, should be investigated to provide adequate and comfortable breast support. The compression sports bra provided more comfortable support than the encapsulation sports bra for these Chinese women when running on a treadmill. However, these women perceived higher bra discomfort when wearing the compression bra when stationary. Further research is needed to modify the design of sports bras, particularly the straps, to provide adequate and comfortable breast support.

  14. Dissociation between wanting and liking for alcohol and caffeine: A test of the Incentive Sensitisation Theory.

    PubMed

    Arulkadacham, Lilani J; Richardson, Ben; Staiger, Petra K; Kambouropoulos, Nicolas; O'Donnell, Renée L; Ling, Mathew

    2017-07-01

    Limited human studies have directly tested the dissociation between wanting and liking with human substance users, a core tenet of the Incentive Sensitisation Theory (IST). The aim of this study is to test the dissociation between wanting and liking in humans across two commonly used licit substances, alcohol and caffeine. The STRAP-R (Sensitivity To Reinforcement of Addictive and other Primary Rewards) questionnaire was administered to 285 alcohol users (mean age=33.30, SD= 8.83) and 134 coffee users (mean age=33.05, SD=8.10) ranging in their levels of substance use to assess wanting and liking. Findings showed that in high risk alcohol users wanting may drive alcohol consumption more so than liking, compared with low risk alcohol users. However, wanting and liking did not significantly dissociate as alcohol consumption increased. These findings partially support IST. Additionally, IST was not supported in coffee users. It is possible that caffeine functions differently at the neurological level compared with alcohol, perhaps explaining the lack of dissociation emerging in coffee users as caffeine use increased. Nevertheless, the current study makes several contributions to IST research. Future studies should focus on utilising the STRAP-R with a clinically dependent sample to test the dissociation between wanting and liking.

  15. RF current distribution and topology of RF sheath potentials in front of ICRF antennae

    NASA Astrophysics Data System (ADS)

    Colas, L.; Heuraux, S.; Brémond, S.; Bosia, G.

    2005-08-01

    The 2D (radial/poloidal) spatial topology of RF-induced convective cells developing radially in front of ion cyclotron range of frequency (ICRF) antennae is investigated, in relation to the spatial distribution of RF currents over the metallic structure of the antenna. This is done via a Green's function, determined from the ICRF wave coupling equations, and well-suited to open field lines extending toroidally far away on both sides of the antenna. Using such formalism, combined with a full-wave calculation using the 3D antenna code ICANT (Pécoul S. et al 2000 Comput. Phys. Commun. 146 166-87), two classes of convective cells are analysed. The first one appears in front of phased arrays of straps, and depending on the strap phasing, its topology is interpreted using the poloidal profiles of either the RF current or the RF voltage of the strip line theory. The other class of convective cells is specific to antenna box corners and is evidenced for the first time. Based on such analysis, general design rules are worked out in order to reduce the RF-sheath potentials, which generalize those proposed in the earlier literature, and concrete antenna design options are tested numerically. The merits of aligning all strap centres on the same (tilted) flux tube, and of reducing the antenna box toroidal conductivity in its lower and upper parts, are discussed.

  16. Integrated fiber optic structural health sensors for inflatable space habitats

    NASA Astrophysics Data System (ADS)

    Ohanian, Osgar John; Garg, Naman; Castellucci, Matthew A.

    2017-04-01

    Inflatable space habitats offer many advantages for future space missions; however, the long term integrity of these flexible structures is a major concern in harsh space environments. Structural Health Monitoring (SHM) of these structures is essential to ensure safe operation, provide early warnings of damage, and measure structural changes over long periods of time. To address this problem, the authors have integrated distributed fiber optic strain sensors to measure loading and to identify the occurrence and location of damage in the straps and webbing used in the structural restraint layer. The fiber optic sensors employed use Rayleigh backscatter combined with optical frequency domain reflectometry to enable measurement of strain every 0.65 mm (0.026 inches) along the sensor. The Kevlar woven straps that were tested exhibited large permanent deformation during initial cycling and continued to exhibit hysteresis thereafter, but there was a consistent linear relationship between the sensor's measurement and the actual strain applied. Damage was intentionally applied to a tensioned strap, and the distributed strain measurement clearly identified a change in the strain profile centered on the location of the damage. This change in structural health was identified at a loading that was less than half of the ultimate loading that caused a structural failure. This sensing technique will be used to enable integrated SHM sensors to detect loading and damage in future inflatable space habitat structures.

  17. Breast reduction

    MedlinePlus

    ... may be moved higher to reposition them for cosmetic reasons. In the most common procedure: The surgeon ... numbness or tingling in your arms or hands. Cosmetic problems, such as persistent bra-strap groove, scar- ...

  18. Single-stage-to-orbit performance enhancement from take-off thrust augmentation

    NASA Astrophysics Data System (ADS)

    Galati, Terence; Elkins, Travis

    1997-01-01

    Thrust augmentation offers the Single Stage to Orbit (SSTO) space launch vehicle improved payload capability while reducing vehicle weight and cost. Optimization of vehicle configuration and flight profile are studied. Using a 612,000 kg Gross Lift Off Weight (GLOW) SSTO with three Castor® strap-on motors, payloads in excess of 18,000 kg to Low Earth Orbit (LEO) are achievable. Emphasis is placed on finding vehicle optimums in the 9,000 kg payload range to capture over 80% of commercial payloads. Strap-on boosters allow a small SSTO vehicle to fly with a mass fraction of only 0.88 and LOX/H2 engines operating at 445 sec vacuum specific impulse. Payload sensitivity due to variations of mass fraction, Isp and pitch rate are quantified.

  19. Preventing Proximal Adjacent Level Kyphosis With Strap Stabilization.

    PubMed

    Zaghloul, Khaled M; Matoian, Brett J; Denardin, Nicholas B; Patel, Vikas V

    2016-07-01

    A substantial proportion of patients develop proximal junctional kyphosis following spinal surgery. To combat this postoperative change, several techniques have focused on maintaining the structural integrity of adjacent spinal levels and adapting the proximal end of the fusion construct to accommodate the increased mechanical stressors produced by long spinal fusion. The use of Mersilene tape (Ethicon, Somerville, New Jersey) for spine and orthopedic surgery is well documented, although considerably less is known about its use for preventing proximal junctional kyphosis. This article describes a proposed technique using Mersilene tape to provide a check-rein strap stabilization at the proximal end of fusion constructs. Initial data suggest that use of this technique may prevent formation of proximal junctional kyphosis. [Orthopedics. 2016; 39(4):e794-e799.]. Copyright 2016, SLACK Incorporated.

  20. 50 CFR 300.109 - Gear disposal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... articles and substances include, but are not limited to, fishing gear, net scraps, bale straps, plastic bags, oil drums, petroleum containers, oil, toxic chemicals or any manmade items retrieved in a...

  1. 50 CFR 300.109 - Gear disposal.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... articles and substances include, but are not limited to, fishing gear, net scraps, bale straps, plastic bags, oil drums, petroleum containers, oil, toxic chemicals or any manmade items retrieved in a...

  2. The feasibility of laryngoscope-guided tracheal intubation in microgravity during parabolic flight: a comparison of two techniques.

    PubMed

    Groemer, Gernot E; Brimacombe, Joseph; Haas, Thorsten; de Negueruela, Cristina; Soucek, Alexander; Thomsen, Michael; Keller, Christian

    2005-11-01

    We determined the feasibility of laryngoscope-guided tracheal intubation (LG-TI) in microgravity obtained during parabolic flight and tested the hypothesis that LG-TI is similarly successful in the free-floating condition, with the patient's head gripped between the anesthesiologist's knees, as in the restrained condition, with the torso strapped to the surface. Three personnel with no experience in airway management or microgravity participated in the study. LG-TI of a sophisticated full-size manikin was attempted on seven occasions in each condition by each investigator after ground-based training. The parabolic flights, which took place in an Airbus 300 over the Atlantic Ocean, provided 23 s of microgravity. During this time, the investigator opened a box with airway equipment, performed LG-TI, and attached and held onto a self-inflating bag. The efficacy of ventilation was assessed during level flight by squeezing the bag and noting whether the manikin sensors indicated a tidal volume > or =300 mL. There were no differences in ventilation success (41% versus 33%) or time to successful insertion (both 18 s) between the free-floating and the restrained conditions. More than 90% of failures were caused by the inability to insert the tracheal tube within 23 s. There were no differences in performance among investigators. We conclude that LG-TI is feasible in microgravity obtained during parabolic flight, but the success rate is infrequent because of severe time restrictions. There were no differences in success rate between the free-floating condition, with the head gripped between the knees, and the restrained condition, with the torso strapped to the surface.

  3. The Pineal Gland

    ERIC Educational Resources Information Center

    Kimbrough, T. Daniel; Llewellyn, Gerald C.

    1973-01-01

    Describes a surgical technique for performing pinealectomics, applicable to classroom and laboratory studies, by using a head-holding device for small animals and a flat dissecting tray outfitted with holding straps for larger animals. (CC)

  4. 50 CFR 600.510 - Gear avoidance and disposal.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... any marine resource, including marine mammals and birds, except in cases of emergency involving the..., fishing gear, net scraps, bale straps, plastic bags, oil drums, petroleum containers, oil, toxic chemicals...

  5. Sweat collection capsule

    NASA Technical Reports Server (NTRS)

    Delaplaine, R. W.; Greenleaf, J. E.

    1979-01-01

    Capsule, with filter paper insert, is used to collect sweat for rate monitoring, chromatographic analysis, or active sweat gland location within specified area. Construction of capsule allows change of inserts while device remains strapped in place.

  6. Fluticasone Oral Inhalation

    MedlinePlus

    ... the inhaler is at room temperature. Remove the cap from the mouthpiece. The strap on the side of the cap will stay attached to the actuator to keep the cap from getting lost. Check the mouthpiece for dirt ...

  7. Ergonomic Strategies for Using a Purse

    MedlinePlus

    ... a Heavy Purse • Heavy purses worn over one shoulder cause uneven weight distribution across the back muscles and may restrict blood flow at the shoulder. • Heavy purses and shoulder straps without padding place ...

  8. Bulkhead insert for an internal combustion engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maki, Clifford E.; Chottiner, Jeffrey Eliot; Williams, Rick L.

    An engine includes a cylinder block defining at least one main bearing bulkhead adjacent to a cylinder, and a crankshaft rotatably housed within the block by a main bearing. A bulkhead insert has a cap portion, and an insert portion provided within the bulkhead. The insert portion has having first and second end regions connected by first and second straps. Each strap having a flanged beam cross section. The first and second ends of the insert portion are configured to connect a main bearing cap column to a cylinder head column. Each of the first and second end regions definemore » at least one protrusion having a surface substantially normal to engine combustion and reactive loads. The cap portion is configured to mate with the first end region at the main bearing cap column and support the main bearing.« less

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abercrombie, Robert Knox; Richardson, Gregory David; Scudiere, Matthew Bligh

    A pad is disclosed for use in a weighing system for weighing a load. The pad includes a weighing platform, load cells, and foot members. Improvements to the pad reduce or substantially eliminate rotation of one or more of the corner foot members. A flexible foot strap disposed between the corner foot members reduces rotation of the respective foot members about vertical axes through the corner foot members and couples the corner foot members such that rotation of one corner foot member results in substantially the same amount of rotation of the other corner foot member. In a strapless variantmore » one or more fasteners prevents substantially all rotation of a foot member. In a diagonal variant, a foot strap extends between a corner foot member and the weighing platform to reduce rotation of the foot member about a vertical axis through the corner foot member.« less

  10. Spine immobilization apparatus

    NASA Technical Reports Server (NTRS)

    Lambson, K. H.; Vykukal, H. C. (Inventor)

    1981-01-01

    The apparatus makes use of a normally flat, flexible bladder filled with beads or micro-balloons that form a rigid mass when the pressure within the bladder is decreased below ambient through the use of a suction pump so that the bladder can be conformed to the torso of the victim and provide the desired restraint. The bladder is strapped to the victim prior to being rigidified by an arrangement of straps which avoid the stomach area. The bladder is adapted to be secured to a rigid support, i.e., a rescue chair, so as to enable removal of a victim after the bladder has been made rigid. A double sealing connector is used to connect the bladder to the suction pump and a control valve is employed to vary the pressure within the bladder so as to soften and harden the bladder as desired.

  11. Ankle-Dorsiflexion Range of Motion After Ankle Self-Stretching Using a Strap

    PubMed Central

    Jeon, In-cheol; Kwon, Oh-yun; Yi, Chung-Hwi; Cynn, Heon-Seock; Hwang, Ui-jae

    2015-01-01

    Context  A variety of ankle self-stretching exercises have been recommended to improve ankle-dorsiflexion range of motion (DFROM) in individuals with limited ankle dorsiflexion. A strap can be applied to stabilize the talus and facilitate anterior glide of the distal tibia at the talocrural joint during ankle self-stretching exercises. Novel ankle self-stretching using a strap (SSS) may be a useful method of improving ankle DFROM. Objective  To compare the effects of 2 ankle-stretching techniques (static stretching versus SSS) on ankle DFROM. Design  Randomized controlled clinical trial. Setting  University research laboratory. Patients or Other Participants  Thirty-two participants with limited active dorsiflexion (<20°) while sitting (14 women and 18 men) were recruited. Main Outcome Measure(s)  The participants performed 2 ankle self-stretching techniques (static stretching and SSS) for 3 weeks. Active DFROM (ADFROM), passive DFROM (PDFROM), and the lunge angle were measured. An independent t test was used to compare the improvements in these values before and after the 2 stretching interventions. The level of statistical significance was set at α = .05. Results  Active DFROM and PDFROM were greater in both stretching groups after the 3-week interventions. However, ADFROM, PDFROM, and the lunge angle were greater in the SSS group than in the static-stretching group (P < .05). Conclusions  Ankle SSS is recommended to improve ADFROM, PDFROM, and the lunge angle in individuals with limited DFROM. PMID:26633750

  12. Parabolic trough solar collector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Eaton, J.H.

    1985-01-15

    A parabolic trough solar collector using reflective flexible materials is disclosed. A parabolic cylinder mirror is formed by stretching a flexible reflecting material between two parabolic end formers. The formers are held in place by a spreader bar. The resulting mirror is made to track the sun, focusing the sun's rays on a receiver tube. The ends of the reflective material are attached by glue or other suitable means to attachment straps. The flexible mirror is then attached to the formers. The attachment straps are mounted in brackets and tensioned by tightening associated nuts on the ends of the attachmentmore » straps. This serves both to stretch the flexible material orthogonal to the receiver tube and to hold the flexible material on the formers. The flexible mirror is stretched in the direction of the receiver tube by adjusting tensioning nuts. If materials with matching coefficients of expansion for temperature and humidity have been chosen, for example, aluminum foil for the flexible mirror and aluminum for the spreader bar, the mirror will stay in adjustment through temperature and humidity excursions. With dissimilar materials, e.g., aluminized mylar or other polymeric material and steel, spacers can be replaced with springs to maintain proper adjustment. The spreader bar cross section is chosen to be in the optic shadow of the receiver tube when tracking and not to intercept rays of the sun that would otherwise reach the receiver tube. This invention can also be used to make non-parabolic mirrors for other apparatus and applications.« less

  13. Rigid removable cover for dorsal wound protection and tube fixation in pigs.

    PubMed

    Stynes, G D; Kiroff, G K; Morrison, W A; Edwards, G A; Page, R S; Kirkland, M A

    2016-04-01

    To report the design and benefits of a rigid polyethylene cover 'shell' for the protection of dorsal torso wounds and tube fixation in pigs. Open C-shaped polyethylene shells were designed to protect wounds and dressings on the dorsum of pigs used in research into negative pressure dressing-assisted wound healing. The shells were designed to resist trauma and contamination, to be comfortable and expansible, and to facilitate tube fixation and management. Strap fixation was optimised during experimentation. Efficacy was assessed by direct observation of dressing and wound protection, tube integrity and by macroscopic and microscopic assessments of wound healing. The shells effectively protected the wounds against blunt and sharp trauma, were simple to remove and reapply, were well tolerated and allowed for growth of the pigs. Circumferential neck straps attached by lateral straps to the shells proved critical. There was no wound infection or inflammation underlying the shells. Porting tubing via mid-dorsal holes in the shells and affixing the tubing just cranial to these holes prevented tube damage and traction, permitted tube management from outside the cages and allowed the pigs to move freely without becoming entangled. These shells effectively protected dorsal skin wounds and dressings, prevented tube damage and facilitated tube management in pigs. Similar systems may be useful for other production animals for wound management and for tube management with negative pressure wound healing, drain tubes or the delivery of nutrition, fluids or medications. © 2016 Australian Veterinary Association.

  14. Elastic Constants of Ni-Mn-Ga Magnetic Shape Memory Alloys

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stipcich, M.; Manosa, L.; Planes, A.

    2004-01-01

    We have measured the adiabatic second order elastic constants of two Ni-Mn-Ga magnetic shape memory crystals with different martensitic transition temperatures, using ultrasonic methods. The temperature dependence of the elastic constants has been followed across the ferromagnetic transition and down to the martensitic transition temperature. Within experimental errors no noticeable change in any of the elastic constants has been observed at the Curie point. The temperature dependence of the shear elastic constant C' has been found to be very different for the two alloys. Such a different behavior is in agreement with recent theoretical predictions for systems undergoing multi-stage structuralmore » transitions.« less

  15. Nanoscale elasticity mappings of micro-constituents of abalone shell by band excitation-contact resonance force microscopy

    NASA Astrophysics Data System (ADS)

    Li, Tao; Zeng, Kaiyang

    2014-01-01

    The macroscopic mechanical properties of the abalone shell have been studied extensively in the literature, but the in situ nanoscale elasticity of various micro-constituents in the shell have not been characterized and reported yet. In this study, the nanoscale elasticity mappings including different micro-constituents in abalone shell were observed by using the Contact Resonance Force Microscopy (CR-FM) technique. CR-FM is one of the advanced scanning probe microscopy techniques that is able to quantify the local elastic moduli of various materials in a non-destructive manner. Instead of an average value, an elasticity mapping that reveals the nanoscale variations of elastic moduli with location can be extracted and correlated with the topography of the structure. Therefore in this study, by adopting the CR-FM technique that is incorporated with the band excitation technique, the elasticity variations of the abalone shell caused by different micro-constituents and crystal orientations are reported, and the elasticity values of the aragonite and calcite nanograins are quantified.The macroscopic mechanical properties of the abalone shell have been studied extensively in the literature, but the in situ nanoscale elasticity of various micro-constituents in the shell have not been characterized and reported yet. In this study, the nanoscale elasticity mappings including different micro-constituents in abalone shell were observed by using the Contact Resonance Force Microscopy (CR-FM) technique. CR-FM is one of the advanced scanning probe microscopy techniques that is able to quantify the local elastic moduli of various materials in a non-destructive manner. Instead of an average value, an elasticity mapping that reveals the nanoscale variations of elastic moduli with location can be extracted and correlated with the topography of the structure. Therefore in this study, by adopting the CR-FM technique that is incorporated with the band excitation technique, the elasticity variations of the abalone shell caused by different micro-constituents and crystal orientations are reported, and the elasticity values of the aragonite and calcite nanograins are quantified. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr05292c

  16. CYTOTOXICITY OF INTERMAXILLARY ORTHODONTIC ELASTICS OF DIFFERENT COLORS: AN IN VITRO STUDY

    PubMed Central

    dos Santos, Rogério Lacerda; Pithon, Matheus Melo; Mendes, Gabriella da Silva; Romanos, Maria Teresa Villela; Ruellas, Antônio Carlos de Oliveira

    2009-01-01

    Objectives: Natural latex does not fall into the category of materials known to be entirely inoffensive. The purpose of this in vitro study was to test the hypothesis that there is no difference in the cytotoxicity between elastics of different colors and those from different manufacturers. Material and Methods: Different latex intraoral elastics of different colors (5/16 = 7.9 mm, mean load) were compared. The sample was divided into 7 groups of 24 elastics each: Group T (TP Orthodontics, natural latex elastics, control); Groups U1, U2, U3, U4, U5 and U6 (Uniden, natural latex elastics and colored elastics, namely, green, pink, yellow, red and purple, respectively). Cytotoxicity assays were performed by using cell culture medium containing epithelioid-type cells (Hep-2 line) derived from human laryngeal carcinoma. The cytotoxicity was evaluated by using the "dye-uptake" test, which was employed at two different moments (0 and 24 h). Data were compared by analysis of variance (ANOVA) and Tukey's test (p<0.05). Results: There was statistically significant difference (p<0.05) between Group T and all other groups (U1, U2, U3, U4, U5 and U6) at 0 and 24 h. No statistically significant difference (p<0.05) was found between Groups U1 and U5, U1 and U6, U2 and U3, U2 and U4, U2 and U5, U2 and U6, U3 and U4, U3 and U5, U3 and U6, U4 and U5, U4 and U6, and U5 and U6 at 0 and 24 h. Conclusions: The TP Orthodontics elastics promoted less cell lysis compared to the Uniden elastics regardless of their color. PMID:19668992

  17. Review of U.S. EPA Office of Research and Development's Research Programs

    EPA Pesticide Factsheets

    A review report of the Office of Research and Development’s (ORD) Strategic Research Action Plans (StRAPs) and the cross-cutting program Roadmaps for Environmental Justice and Global Climate Change.

  18. 77 FR 58354 - Foreign-Trade Zone 265-Conroe, TX; Notification of Proposed Production Activity, Bauer...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-20

    ..., packing crates, decals, textile straps, mirrors, insulation, articles of steel (shapes, angles, bars, rods...-conditioner components, heat exchangers, filters, fire extinguishers, hydraulic jacks/hoists, parts of boring...

  19. 46 CFR 154.514 - Piping: Electrical bonding.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... and Process Piping Systems § 154.514 Piping: Electrical bonding. (a) Cargo tanks or piping that are... strap attached by welding or bolting. (2) Two or more bolts that give metal to metal contact between the...

  20. Cooling vest

    NASA Technical Reports Server (NTRS)

    Kosmo, J.; Kane, J.; Coverdale, J.

    1977-01-01

    Inexpensive vest of heat-sealable urethane material, when strapped to person's body, presents significant uncomplicated cooling system for environments where heavy accumulation of metabolic heat exists. Garment is applicable to occupations where physical exertion is required under heavy protective clothing.

  1. Wave propagation of carbon nanotubes embedded in an elastic medium

    NASA Astrophysics Data System (ADS)

    Natsuki, Toshiaki; Hayashi, Takuya; Endo, Morinobu

    2005-02-01

    This paper presents analytical models of wave propagation in single- and double-walled carbon nanotubes, as well as nanotubes embedded in an elastic matrix. The nanotube structures are treated within the multilayer thin shell approximation with the elastic properties taken to be those of the graphene sheet. The double-walled nanotubes are coupled together through the van der Waals force between the inner and outer nanotubes. For carbon nanotubes embedded in an elastic matrix, the surrounding elastic medium can be described by a Winkler model. Tube wave propagation of both symmetrical and asymmetrical modes can be analyzed based on the present elastic continuum model. It is found that the asymmetrical wave behavior of single- and double-walled nanotubes is significantly different. The behavior is also different from that in the surrounding elastic medium.

  2. Comparative research of redundant strap down inertial navigation system based on different configuration schemes

    NASA Astrophysics Data System (ADS)

    Yu, Yuting; Cheng, Ming

    2018-05-01

    Aiming at various configuration scheme and inertial measurement units of Strapdown Inertial Navigation System, selected tetrahedron skew configuration and coaxial orthogonal configuration by nine low cost IMU to build system. Calculation and simulation the performance index, reliability and fault diagnosis ability of the navigation system. Analysis shows that the reliability and reconfiguration scheme of skew configuration is superior to the orthogonal configuration scheme, while the performance index and fault diagnosis ability of the system are similar. The work in this paper provides a strong reference for the selection of engineering applications.

  3. Budget Constraints Affect Male Rats’ Choices between Differently Priced Commodities

    PubMed Central

    Kalenscher, Tobias

    2015-01-01

    Demand theory can be applied to analyse how a human or animal consumer changes her selection of commodities within a certain budget in response to changes in price of those commodities. This change in consumption assessed over a range of prices is defined as demand elasticity. Previously, income-compensated and income-uncompensated price changes have been investigated using human and animal consumers, as demand theory predicts different elasticities for both conditions. However, in these studies, demand elasticity was only evaluated over the entirety of choices made from a budget. As compensating budgets changes the number of attainable commodities relative to uncompensated conditions, and thus the number of choices, it remained unclear whether budget compensation has a trivial effect on demand elasticity by simply sampling from a different total number of choices or has a direct effect on consumers’ sequential choice structure. If the budget context independently changes choices between commodities over and above price effects, this should become apparent when demand elasticity is assessed over choice sets of any reasonable size that are matched in choice opportunities between budget conditions. To gain more detailed insight in the sequential choice dynamics underlying differences in demand elasticity between budget conditions, we trained N=8 rat consumers to spend a daily budget by making a number of nosepokes to obtain two liquid commodities under different price regimes, in sessions with and without budget compensation. We confirmed that demand elasticity for both commodities differed between compensated and uncompensated budget conditions, also when the number of choices considered was matched, and showed that these elasticity differences emerge early in the sessions. These differences in demand elasticity were driven by a higher choice rate and an increased reselection bias for the preferred commodity in compensated compared to uncompensated budget conditions, suggesting a budget context effect on relative valuation. PMID:26053764

  4. Budget Constraints Affect Male Rats' Choices between Differently Priced Commodities.

    PubMed

    van Wingerden, Marijn; Marx, Christine; Kalenscher, Tobias

    2015-01-01

    Demand theory can be applied to analyse how a human or animal consumer changes her selection of commodities within a certain budget in response to changes in price of those commodities. This change in consumption assessed over a range of prices is defined as demand elasticity. Previously, income-compensated and income-uncompensated price changes have been investigated using human and animal consumers, as demand theory predicts different elasticities for both conditions. However, in these studies, demand elasticity was only evaluated over the entirety of choices made from a budget. As compensating budgets changes the number of attainable commodities relative to uncompensated conditions, and thus the number of choices, it remained unclear whether budget compensation has a trivial effect on demand elasticity by simply sampling from a different total number of choices or has a direct effect on consumers' sequential choice structure. If the budget context independently changes choices between commodities over and above price effects, this should become apparent when demand elasticity is assessed over choice sets of any reasonable size that are matched in choice opportunities between budget conditions. To gain more detailed insight in the sequential choice dynamics underlying differences in demand elasticity between budget conditions, we trained N=8 rat consumers to spend a daily budget by making a number of nosepokes to obtain two liquid commodities under different price regimes, in sessions with and without budget compensation. We confirmed that demand elasticity for both commodities differed between compensated and uncompensated budget conditions, also when the number of choices considered was matched, and showed that these elasticity differences emerge early in the sessions. These differences in demand elasticity were driven by a higher choice rate and an increased reselection bias for the preferred commodity in compensated compared to uncompensated budget conditions, suggesting a budget context effect on relative valuation.

  5. Pulsatile blood flow in elastic artery with model aneurysm

    NASA Astrophysics Data System (ADS)

    Nikolov, N.; Radev, St.; Tabakova, S.

    2017-11-01

    The mathematical modeling and numerical simulations are expected to play an important role to predict the genesis of different cardiovascular diseases, such as the formation and rupture of aneurysms. In the present work, the numerical solutions of the oscillatory blood flow are constructed for an elastic artery with a model aneurysm by use of the software ANSYS. It is observed that the artery elastic strain behaves in a different way: stably or unstably depending on the different combinations between the flow parameter (outlet pressure) and the elastic modulus of the artery wall.

  6. What Happens in the Emergency Room?

    MedlinePlus

    ... all of this information is recorded in the computer and saved. injection: a shot IV: intravenous catheter, which is a thin plastic tube inserted into your vein to give you medicine papoose: a soft board with Velcro straps that ...

  7. Review of U.S. EPA Office of Research and Development's Research Programs - 2017

    EPA Pesticide Factsheets

    A review report of the Office of Research and Development’s (ORD) Strategic Research Action Plans (StRAPs) and the cross-cutting program Roadmaps for Environmental Justice and Global Climate Change.

  8. 78 FR 33052 - Foreign-Trade Zone (FTZ) 267-Fargo, North Dakota; Notification of Proposed Production Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-03

    ... sales, CNH would be able to choose the duty rates during customs entry procedures that apply to...; ground straps; latches; plates; pumps; valves; fans; bushings; ballast assemblies; heaters; speakers...

  9. 33 CFR 183.532 - Clips, straps, and hose clamps.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... (CONTINUED) BOATING SAFETY BOATS AND ASSOCIATED EQUIPMENT Fuel Systems Equipment Standards § 183.532 Clips... under § 183.590, a hose clamp installed on a fuel line system requiring metallic fuel lines or “USCG...

  10. Astronaut Alan Bean participates in lunar surface simulation

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Astronaut Alan L. Bean, lunar module pilot of the Apollo 12 lunar landing mission, participates in lunar surface simulation training in bldg 29 at the Manned Spacecraft Center. Bean is strapped to a one-sixth gravity simulator.

  11. Robotic Firefighting Technologies

    DTIC Science & Technology

    2010-12-01

    designed to strap to the firefighter’s waist line; the ergonomic fit provides comfort to the operator during use of the Fire Defender UFV. Robotic...5 3.2. Technical Design Approach .................................................................................................7...3.2.1. System Design Modification................................................................................................7 3.3. System

  12. Strapped Calix[4]pyrroles Bearing an 1,3-Indanedione at a β-Pyrrolic Position: Chemodosimeters for the Cyanide Anion

    PubMed Central

    Kim, Sook-Hee; Hong, Seong-Jin; Yoo, Jaeduk; Kim, Sung Kuk; Sessler, Janathan L.; Lee, Chang-Hee

    2014-01-01

    A strapped calix[4]pyrrole bearing an 1,3-indanedione group at a β-pyrrolic position has been synthesized and studied as a ratiometric cyanide selective chemosensor. A concentration-dependent bleaching of the initial yellow color was observed upon addition of the cyanide anion. The bleaching, which was observed exclusively with the cyanide anion, occurred even in the presence of other anions. Spectroscopic studies provides support for a mechanistic interpretation wherein the cyanide anion forms a complex with the receptor (K = 2.78 × 104 M-1) through a fast equilibrium, which is followed by slow nucleophilic addition to the β-position of the 1,3-indanedione group. A minimum inhibitory effect from other anions was observed, a feature that could be beneficial in the selective sensing of the cyanide anion. PMID:19639968

  13. Vibration isolation and pressure compensation apparatus for sensitive instrumentation

    NASA Technical Reports Server (NTRS)

    Averill, R. D. (Inventor)

    1983-01-01

    A system for attenuating the inherent vibration associated with a mechanical refrigeration unit employed to cryogenically cool sensitive instruments used in measuring chemical constituents of the atmosphere is described. A modular system including an instrument housing and a reaction bracket with a refrigerator unit floated there between comprise the instrumentation system. A pair of evacuated bellows that "float' refrigerator unit and provide pressure compensation at all levels of pressure from seal level to the vacuum of space. Vibration isolators and when needed provide additional vibration damping for the refrigerator unit. A flexible thermal strap (20 K) serves to provide essentially vibration free thermal contact between cold tip of the refrigerator unit and the instrument component mounted on the IDL mount. Another flexible strap (77 K) serves to provide vibration free thermal contact between the TDL mount thermal shroud and a thermal shroud disposed about the thermal shaft.

  14. Finite element analysis for the evaluation of protective functions of helmets against ballistic impact.

    PubMed

    Lee, H P; Gong, S W

    2010-10-01

    The ballistic impact of a human head model protected by a Personnel Armor System Ground Troops Kevlar® helmet is analysed using the finite element method. The emphasis is to examine the effect of the interior cushioning system as a shock absorber in mitigating ballistic impact to the head. The simulations of the frontal and side impacts of the full metal jacket (FMJ) and fragment-simulating projectile (FSP) were carried out using LS-DYNA. It was found that the Kevlar® helmet with its interior nylon and leather strap was able to defeat both the FMJ and FSP without the projectiles penetrating the helmet. However, the head injuries caused by the FMJ impact can be fatal due to the high stiffness of the interior strap. The bulge section at the side of the Kevlar® helmet had more room for deformation that resulted in less serious head injuries.

  15. Liquid-assisted tunable metasurface for simultaneous manipulation of surface elastic and acoustic waves

    NASA Astrophysics Data System (ADS)

    Yuan, Si-Min; Ma, Tian-Xue; Chen, A.-Li; Wang, Yue-Sheng

    2018-03-01

    A tunable and multi-functional one-dimensional metasurface, which is formed by engraving periodic semi-ellipse grooves on the surface of an aluminum half-space, is proposed in this paper. One characteristic of the metasurface is the manipulation of multi-physical fields, i.e. it could be utilized to manipulate surface elastic and acoustic waves simultaneously. The dispersion curves of the elastic and acoustic waves can be effectively tuned by adding liquids into the grooves. Based on the tunability different applications can be realized by adding different volumes of different liquids into the grooves. As an example, simultaneous rainbow trapping of the surface elastic and acoustic waves is demonstrated in the metasurface. Moreover, a resonant cavity where the elastic and acoustic waves are highly confined is reported. The proposed metasurface paves the way to the design of multi-functional devices for simultaneous control of elastic and acoustic waves.

  16. Consumer brand choice: individual and group analyses of demand elasticity.

    PubMed

    Oliveira-Castro, Jorge M; Foxall, Gordon R; Schrezenmaier, Teresa C

    2006-03-01

    Following the behavior-analytic tradition of analyzing individual behavior, the present research investigated demand elasticity of individual consumers purchasing supermarket products, and compared individual and group analyses of elasticity. Panel data from 80 UK consumers purchasing 9 product categories (i.e., baked beans, biscuits, breakfast cereals, butter, cheese, fruit juice, instant coffee, margarine and tea) during a 16-week period were used. Elasticity coefficients were calculated for individual consumers with data from all or only 1 product category (intra-consumer elasticities), and for each product category using all data points from all consumers (overall product elasticity) or 1 average data point per consumer (interconsumer elasticity). In addition to this, split-sample elasticity coefficients were obtained for each individual with data from all product categories purchased during weeks 1 to 8 and 9 to 16. The results suggest that: 1) demand elasticity coefficients calculated for individual consumers purchasing supermarket food products are compatible with predictions from economic theory and behavioral economics; 2) overall product elasticities, typically employed in marketing and econometric research, include effects of interconsumer and intraconsumer elasticities; 3) when comparing demand elasticities of different product categories, group and individual analyses yield similar trends; and 4) individual differences in demand elasticity are relatively consistent across time, but do not seem to be consistent across products. These results demonstrate the theoretical, methodological, and managerial relevance of investigating the behavior of individual consumers.

  17. Consumer Brand Choice: Individual and Group Analyses of Demand Elasticity

    PubMed Central

    Oliveira-Castro, Jorge M; Foxall, Gordon R; Schrezenmaier, Teresa C

    2006-01-01

    Following the behavior-analytic tradition of analyzing individual behavior, the present research investigated demand elasticity of individual consumers purchasing supermarket products, and compared individual and group analyses of elasticity. Panel data from 80 UK consumers purchasing 9 product categories (i.e., baked beans, biscuits, breakfast cereals, butter, cheese, fruit juice, instant coffee, margarine and tea) during a 16-week period were used. Elasticity coefficients were calculated for individual consumers with data from all or only 1 product category (intra-consumer elasticities), and for each product category using all data points from all consumers (overall product elasticity) or 1 average data point per consumer (interconsumer elasticity). In addition to this, split-sample elasticity coefficients were obtained for each individual with data from all product categories purchased during weeks 1 to 8 and 9 to 16. The results suggest that: 1) demand elasticity coefficients calculated for individual consumers purchasing supermarket food products are compatible with predictions from economic theory and behavioral economics; 2) overall product elasticities, typically employed in marketing and econometric research, include effects of interconsumer and intraconsumer elasticities; 3) when comparing demand elasticities of different product categories, group and individual analyses yield similar trends; and 4) individual differences in demand elasticity are relatively consistent across time, but do not seem to be consistent across products. These results demonstrate the theoretical, methodological, and managerial relevance of investigating the behavior of individual consumers. PMID:16673823

  18. Restraint harness performance during flight maneuvers: a parametric study.

    PubMed

    Du, Cheng-Fei; Liu, Xiao-Yu; Wang, Li-Zhen; Liu, Song-Yang; Fan, Yu-Bo

    2015-05-01

    Modern super agile fighter aircraft are capable of producing an increasing multiaxial acceleration environment which can adversely affect the pilot. An evaluation of the performance of the restraint system during flight maneuvers will benefit restraint designs and, thus, the safety of pilots. A finite element model of a mannequin with PCU-15/P harness restraint was used in this study to investigate how the factors, such as strap material stiffness, friction, and belt tension, affect the performance of restraint systems during impact along the -Gx, -Gy, and -Gz directions. The corresponding maximum displacement of the mannequin's torso was computed. The mannequin moved beyond 74 mm sideways. The change in friction coefficient (FC) from 0.1 to 0.4 decreased the displacement of the lower torso by less than 6.7%. The displacement of the torso decreased as the stiffness of the strap or tension increased. Displacement decreased by 9.3%, 6.0%, and 2.7% for the lower torso under the Gx impact, as the tightening force increased from 20 N to 80 N gradually. However, this changed slightly when the stiffness arrived at 1 E or the tension increased to 60 N. PCU-15/P harness has the poorest performance during side impact and friction plays an unimportant role in affecting its performance. The stiffness of the webbing used in the PCU-15/P harness is sufficiently high. The lap belt has more effect on limiting the movement of the pilot than the shoulder straps, and a tension of 60 N during the adjustment may be enough for conventional flight maneuvers.

  19. EPA Response to Review of Office of Research and Development's Research Programs

    EPA Pesticide Factsheets

    EPA's response to the review report of the Office of Research and Development’s (ORD) Strategic Research Action Plans (StRAPs) and the cross-cutting program Roadmaps for Environmental Justice and Global Climate Change.

  20. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... part of the lazy line attachment system (i.e., any mechanism, such as elephant ears or choker straps... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  1. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... part of the lazy line attachment system (i.e., any mechanism, such as elephant ears or choker straps... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  2. 46 CFR 160.010-4 - General requirements for buoyant apparatus.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... light twine. (h) Each peripheral body type buoyant apparatus without a net or platform on the inside... pigmented in a dark color. A typical method of securing lifelines and pendants to straps of webbing is shown...

  3. 46 CFR 160.010-4 - General requirements for buoyant apparatus.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... light twine. (h) Each peripheral body type buoyant apparatus without a net or platform on the inside... pigmented in a dark color. A typical method of securing lifelines and pendants to straps of webbing is shown...

  4. 46 CFR 160.010-4 - General requirements for buoyant apparatus.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... light twine. (h) Each peripheral body type buoyant apparatus without a net or platform on the inside... pigmented in a dark color. A typical method of securing lifelines and pendants to straps of webbing is shown...

  5. Prosthetic Hand Lifts Heavy Loads

    NASA Technical Reports Server (NTRS)

    Carden, James R.; Norton, William; Belcher, Jewell G.; Vest, Thomas W.

    1991-01-01

    Prosthetic hand designed to enable amputee to lift diverse heavy objects like rocks and logs. Has simple serrated end effector with no moving parts. Prosthesis held on forearm by system of flexible straps. Features include ruggedness, simplicity, and relatively low cost.

  6. Control of elasticity in cast elastomeric shock/vibration isolators

    NASA Technical Reports Server (NTRS)

    Owens, L.; Bright, C.

    1974-01-01

    Elasticity is determined by isolators physical dimensions and by type of elastomer used. Once elastomer is selected and cast between two concentric tubes of device, isolator elasticity will remain fixed. Isolators having same dimensions can be built to different elasticity requirements using same elastomer.

  7. ShearWave™ elastography for evaluation of the elasticity of Hashimoto's thyroiditis.

    PubMed

    Liu, Haifang; Zhu, Yuping; Jiao, Jie; Yuan, Jia; Pu, Tianning; Yong, Qiang

    2018-04-13

    The aim of this study was to assess the elasticity of Hashimoto's thyroiditis in the different processes via supersonic ShearWave™ Elastography (SWE™). Quantitative information is delivered as Young's modulus value expressed in kilo-Pascal (kPa). 30 healthy female and 30 healthy male individuals aging at 40±20 y had undergone conventional ultrasonography and SWE to determine the influence of gender on elasticity of thyroid. Also 60 female and 60 male patients (mean age, 40±20 y) with Hashimoto's thyroiditis in different processes underwent conventional ultrasonography and SWE to determine the elasticity of thyroid in Hashimoto's thyroiditis. Furthermore, the relationship between elasticity values and thyroid peroxidase antibody (TPOAB) in the patients was investigated. We found significant impact of gender on elasticity values of healthy thyroids. Our study showed that increased elasticity values with statistical significance in hyperthyroidism stage, normal thyroid function stage and hypothyroidism were shown. Low degree relationship between elasticity values and TPOAB was found in 60 male patients. However, there was no such correlation in female patients.

  8. Differences in price elasticities of demand for health insurance: a systematic review.

    PubMed

    Pendzialek, Jonas B; Simic, Dusan; Stock, Stephanie

    2016-01-01

    Many health insurance systems apply managed competition principles to control costs and quality of health care. Besides other factors, managed competition relies on a sufficient price-elastic demand. This paper presents a systematic review of empirical studies on price elasticity of demand for health insurance. The objective was to identify the differing international ranges of price elasticity and to find socio-economic as well as setting-oriented factors that influence price elasticity. Relevant literature for the topic was identified through a two-step identification process including a systematic search in appropriate databases and further searches within the references of the results. A total of 45 studies from countries such as the USA, Germany, the Netherlands, and Switzerland were found. Clear differences in price elasticity by countries were identified. While empirical studies showed a range between -0.2 and -1.0 for optional primary health insurance in the US, higher price elasticities between -0.6 and -4.2 for Germany and around -2 for Switzerland were calculated for mandatory primary health insurance. Dutch studies found price elasticities below -0.5. In consideration of all relevant studies, age and poorer health status were identified to decrease price elasticity. Other socio-economic factors had an unclear impact or too limited evidence. Premium level, range of premiums, homogeneity of benefits/coverage and degree of forced decision were found to have a major influence on price elasticity in their settings. Further influence was found from supplementary insurance and premium-dependent employer contribution.

  9. Multiple roles for elastic fibers in the skin.

    PubMed

    Starcher, Barry; Aycock, Ronnie L; Hill, Charles H

    2005-04-01

    Dermal elastic fibers are believed to have a primary role in providing elastic stretch and recoil to the skin. Here we compare the structural arrangement of dermal elastic fibers of chick skin and different animal species. Most elastic fibers in chick skin are derived from cells that line the feather follicle and/or smooth muscle that connects the pterial and apterial muscle bundles to feather follicles. Elastic fibers in the dermis of animals with single, primary hair follicles are derived from cells lining the hair follicle or from the ends of the pili muscle, which anchors the muscle to the matrix or to the hair follicle. Each follicle is interconnected with elastic fibers. Follicles of animals with primary and secondary (wool) hair follicles are also interconnected by elastic fibers, yet only the elastic fibers derived from the primary follicle are connected to each primary follicle. Only the primary hair follicles are connected to the pili muscle. Human skin, but not the skin of other primates, is significantly different from other animals with respect to elastic fiber organization and probably cell of origin. The data suggest that the primary role for elastic fibers in animals, with the possible exception of humans, is movement and/or placement of feathers or hair.

  10. Non-invasive evaluation of liver stiffness after splenectomy in rabbits with CCl4-induced liver fibrosis.

    PubMed

    Wang, Ming-Jun; Ling, Wen-Wu; Wang, Hong; Meng, Ling-Wei; Cai, He; Peng, Bing

    2016-12-14

    To investigate the diagnostic performance of liver stiffness measurement (LSM) by elastography point quantification (ElastPQ) in animal models and determine the longitudinal changes in liver stiffness by ElastPQ after splenectomy at different stages of fibrosis. Liver stiffness was measured in sixty-eight rabbits with CCl 4 -induced liver fibrosis at different stages and eight healthy control rabbits by ElastPQ. Liver biopsies and blood samples were obtained at scheduled time points to assess liver function and degree of fibrosis. Thirty-one rabbits with complete data that underwent splenectomy at different stages of liver fibrosis were then included for dynamic monitoring of changes in liver stiffness by ElastPQ and liver function according to blood tests. LSM by ElastPQ was significantly correlated with histologic fibrosis stage ( r = 0.85, P < 0.001). The optimal cutoff values by ElastPQ were 11.27, 14.89, and 18.21 kPa for predicting minimal fibrosis, moderate fibrosis, and cirrhosis, respectively. Longitudinal monitoring of the changes in liver stiffness by ElastPQ showed that early splenectomy (especially F1) may delay liver fibrosis progression. ElastPQ is an available, convenient, objective and non-invasive technique for assessing liver stiffness in rabbits with CCl 4 -induced liver fibrosis. In addition, liver stiffness measurements using ElastPQ can dynamically monitor the changes in liver stiffness in rabbit models, and in patients, after splenectomy.

  11. Perception of Elasticity in the Kinetic Illusory Object with Phase Differences in Inducer Motion

    PubMed Central

    Masuda, Tomohiro; Sato, Kazuki; Murakoshi, Takuma; Utsumi, Ken; Kimura, Atsushi; Shirai, Nobu; Kanazawa, So; Yamaguchi, Masami K.; Wada, Yuji

    2013-01-01

    Background It is known that subjective contours are perceived even when a figure involves motion. However, whether this includes the perception of rigidity or deformation of an illusory surface remains unknown. In particular, since most visual stimuli used in previous studies were generated in order to induce illusory rigid objects, the potential perception of material properties such as rigidity or elasticity in these illusory surfaces has not been examined. Here, we elucidate whether the magnitude of phase difference in oscillation influences the visual impressions of an object's elasticity (Experiment 1) and identify whether such elasticity perceptions are accompanied by the shape of the subjective contours, which can be assumed to be strongly correlated with the perception of rigidity (Experiment 2). Methodology/Principal Findings In Experiment 1, the phase differences in the oscillating motion of inducers were controlled to investigate whether they influenced the visual impression of an illusory object's elasticity. The results demonstrated that the impression of the elasticity of an illusory surface with subjective contours was systematically flipped with the degree of phase difference. In Experiment 2, we examined whether the subjective contours of a perceived object appeared linear or curved using multi-dimensional scaling analysis. The results indicated that the contours of a moving illusory object were perceived as more curved than linear in all phase-difference conditions. Conclusions/Significance These findings suggest that the phase difference in an object's motion is a significant factor in the material perception of motion-related elasticity. PMID:24205281

  12. Chimpanzee Ham after sucessful MR-2 flight

    NASA Technical Reports Server (NTRS)

    1963-01-01

    Closeup view of the chimpanzee 'Ham', the live test subject for Mercury-Redstone 2 test flight being fed an apple. This photo was taken after his successful recovery from the Atlantic. Note he is still strapped into his special flight couch.

  13. 10. FIRST FLOOR, ENTRY HALL, LOOKING SOUTHWEST TOWARDS FRONT ENTRY ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    10. FIRST FLOOR, ENTRY HALL, LOOKING SOUTHWEST TOWARDS FRONT ENTRY WITH DOOR PARTIALLY CLOSED TO SHOWS ITS RAISED PANEL CONSTRUCTION AND STRAP HINGES - Open Gate Farm, House, Ridge Road, 1 mile East of Elephant Road, Perkasie, Bucks County, PA

  14. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... attachment system (i.e., any mechanism, such as elephant ears or choker straps, used to attach the lazy line... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  15. 50 CFR Appendix D to Part 622 - Specifications for Certified BRDs

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... attachment system (i.e., any mechanism, such as elephant ears or choker straps, used to attach the lazy line... is installed, no part of the lazy line attachment system (i.e., any mechanism, such as elephant ears...

  16. 77 FR 18099 - Special Conditions: Dassault Aviation, Model Falcon 7X Airplanes; Seats With Inflatable Shoulder...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-27

    ... rely on electronic sensors for signaling and a stored gas canister for inflation. These same devices... shoulder strap will not release hazardous quantities of gas or particulate matter into the cabin. 11. The...

  17. 48 CFR 652.242-72 - Shipping Instructions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... dimensions of lumber for struts, frame members, and single diagonal braces Up to 45 kg 19.05 × 57.15mm 46 to... (b) Each box shall be lined with waterproof paper and shall be bound with 19.05mm″ steel straps...

  18. 48 CFR 652.242-72 - Shipping Instructions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... dimensions of lumber for struts, frame members, and single diagonal braces Up to 45 kg 19.05 × 57.15mm 46 to... (b) Each box shall be lined with waterproof paper and shall be bound with 19.05mm″ steel straps...

  19. DETAIL OF CORNERSTONE, WHICH STATES "J.J. DANIELS, BUILDER 1861." NOTE ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    DETAIL OF CORNERSTONE, WHICH STATES "J.J. DANIELS, BUILDER 1861." NOTE ALSO IRON STRAP AT EAST CORNER OF ABUTMENT. - Jackson Covered Bridge, Spanning Sugar Creek, CR 775N (Changed from Spanning Sugar Creek), Bloomingdale, Parke County, IN

  20. View south, wharf B, timber framing, detail of cross bracing, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    View south, wharf B, timber framing, detail of cross bracing, recent galvanized straps, bolts and washers - U.S. Coast Guard Sandy Hook Station, Western Docking Structure, West of intersection of Canfield Road & Hartshorne Drive, Highlands, Monmouth County, NJ

  1. Experimental determination of third-order elastic constants of diamond.

    PubMed

    Lang, J M; Gupta, Y M

    2011-03-25

    To determine the nonlinear elastic response of diamond, single crystals were shock compressed along the [100], [110], and [111] orientations to 120 GPa peak elastic stresses. Particle velocity histories and elastic wave velocities were measured by using laser interferometry. The measured elastic wave profiles were used, in combination with published acoustic measurements, to determine the complete set of third-order elastic constants. These constants represent the first experimental determination, and several differ significantly from those calculated by using theoretical models.

  2. Influence of neural monitoring during thyroid surgery on nerve integrity and postoperative vocal function.

    PubMed

    Engelsman, A F; Warhurst, S; Fraser, S; Novakovic, D; Sidhu, S B

    2018-06-01

    Integrity of the recurrent laryngeal nerve (RLN) and the external branch of the superior laryngeal nerve (EBSLN) can be checked by intraoperative nerve monitoring (IONM) after visualization. The aim of this study was to determine the prevalence and nature of voice dysfunction following thyroid surgery with routine IONM. Thyroidectomies were performed with routine division of strap muscles and nerve monitoring to confirm integrity of the RLN and EBSLN following dissection. Patients were assessed for vocal function before surgery and at 1 and 3 months after operation. Assessment included use of the Voice Handicap Index (VHI) 10, maximum phonation time, fundamental frequency, pitch range, harmonic to noise ratio, cepstral peak prominence and smoothed cepstral peak prominence. A total of 172 nerves at risk were analysed in 102 consecutive patients undergoing elective thyroid surgery. In 23·3 per cent of EBSLNs and 0·6 per cent of RLNs nerve identification required the assistance of IONM in addition to visualization. Nerve integrity was confirmed during surgery for 98·8 per cent of EBSLNs and 98·3 per cent of RLNs. There were no differences between preoperative and postoperative VHI-10 scores. Acoustic voice assessment showed small changes in maximum phonation time at 1 and 3 months after surgery. Where there is routine division of strap muscles, thyroidectomy using nerve monitoring confirmation of RLN and EBSLN function following dissection results in no clinically significant voice change.

  3. Are There Long-Run Effects of the Minimum Wage?

    PubMed Central

    Sorkin, Isaac

    2014-01-01

    An empirical consensus suggests that there are small employment effects of minimum wage increases. This paper argues that these are short-run elasticities. Long-run elasticities, which may differ from short-run elasticities, are policy relevant. This paper develops a dynamic industry equilibrium model of labor demand. The model makes two points. First, long-run regressions have been misinterpreted because even if the short- and long-run employment elasticities differ, standard methods would not detect a difference using US variation. Second, the model offers a reconciliation of the small estimated short-run employment effects with the commonly found pass-through of minimum wage increases to product prices. PMID:25937790

  4. Are There Long-Run Effects of the Minimum Wage?

    PubMed

    Sorkin, Isaac

    2015-04-01

    An empirical consensus suggests that there are small employment effects of minimum wage increases. This paper argues that these are short-run elasticities. Long-run elasticities, which may differ from short-run elasticities, are policy relevant. This paper develops a dynamic industry equilibrium model of labor demand. The model makes two points. First, long-run regressions have been misinterpreted because even if the short- and long-run employment elasticities differ, standard methods would not detect a difference using US variation. Second, the model offers a reconciliation of the small estimated short-run employment effects with the commonly found pass-through of minimum wage increases to product prices.

  5. Evaluation of force degradation characteristics of orthodontic latex elastics in vitro and in vivo.

    PubMed

    Wang, Tong; Zhou, Gang; Tan, Xianfeng; Dong, Yaojun

    2007-07-01

    To evaluate the characteristics of force degradation of latex elastics in clinical applications and in vitro studies. Samples of 3/16-inch latex elastics were investigated, and 12 students between the ages of 12 and 15 years were selected for the intermaxillary and intramaxillary tractions. The elastics in the control groups were set in artificial saliva and dry room conditions and were stretched 20 mm. The repeated-measure two-way analysis of variance and nonlinear regression analysis were used to identify statistical significance. Overall, there were statistically significant differences between the different methods and observation intervals. At 24- and 48-hour time intervals, the force decreased during in vivo testing and in artificial saliva (P < .001), whereas there were no significant differences in dry room conditions (P > .05). In intermaxillary traction the percentage of initial force remaining after 48 hours was 61%. In intramaxillary traction and in artificial saliva the percentage of initial force remaining was 71%, and in room conditions 86% of initial force remained. Force degradation of latex elastics was different according to their environmental conditions. There was significantly more force degradation in intermaxillary traction than in intramaxillary traction. The dry room condition caused the least force loss. There were some differences among groups in the different times to start wearing elastics in intermaxillary traction but no significant differences in intramaxillary traction.

  6. Determination of Spearman Correlation Coefficient (r) to Evaluate the Linear Association of Dermal Collagen and Elastic Fibers in the Perspectives of Skin Injury.

    PubMed

    Kumar, Naveen; Kumar, Pramod; Badagabettu, Satheesha Nayak; Lewis, Melissa Glenda; Adiga, Murali; Padur, Ashwini Aithal

    2018-01-01

    Difference in scar formation at different sites, in different directions at the same site, but with changes in the elasticity of skin with age, sex, and race or in some pathological conditions, is well known to clinicians. The inappropriate collagen syntheses and delayed or lack of epithelialization are known to induce scar formation with negligible elasticity at the site of damage. Changes in the elasticity of scars may be due to an unequal distribution of dermal collagen (C) and elastic (E) fibers. Spearman correlation coefficients ( r ) of collagen and elastic fibers in horizontal (H) and in vertical (V) directions (variables CV, CH, EV, and EH) were measured from the respective quantitative fraction data in 320 skin samples from 32 human cadavers collected at five selected sites over extremities. Spearman's correlation analysis revealed the statistically significant ( p < 0.01) strong positive correlation between C H and C V in all the areas, that is, shoulder joint area ( r = 0.66), wrist ( r = 0.75), forearm ( r = 0.75), and thigh ( r = 0.80), except at the ankle ( r = 0.26, p = 0.14) region. Similarly, positive correlation between E H and E V has been observed at the forearm ( r = 0.65, moderate) and thigh ( r = 0.42, low) regions. However, a significant moderate negative correlation was observed between C V and E V at the forearm ( r = -0.51) and between C H and E H at the thigh region ( r = -0.65). Significant differences of correlations of collagen and elastic fibers in different directions from different areas of extremities were noted. This may be one of the possible anatomical reasons of scar behavior in different areas and different directions of the same area.

  7. Using Response Surface Methods to Correlate the Modal Test of an Inflatable Test Article

    NASA Technical Reports Server (NTRS)

    Gupta, Anju

    2013-01-01

    This paper presents a practical application of response surface methods (RSM) to correlate a finite element model of a structural modal test. The test article is a quasi-cylindrical inflatable structure which primarily consists of a fabric weave, with an internal bladder and metallic bulkheads on either end. To mitigate model size, the fabric weave was simplified by representing it with shell elements. The task at hand is to represent the material behavior of the weave. The success of the model correlation is measured by comparing the four major modal frequencies of the analysis model to the four major modal frequencies of the test article. Given that only individual strap material properties were provided and material properties of the overall weave were not available, defining the material properties of the finite element model became very complex. First it was necessary to determine which material properties (modulus of elasticity in the hoop and longitudinal directions, shear modulus, Poisson's ratio, etc.) affected the modal frequencies. Then a Latin Hypercube of the parameter space was created to form an efficiently distributed finite case set. Each case was then analyzed with the results input into RSM. In the resulting response surface it was possible to see how each material parameter affected the modal frequencies of the analysis model. If the modal frequencies of the analysis model and its corresponding parameters match the test with acceptable accuracy, it can be said that the model correlation is successful.

  8. Elastic fibre organization in the intervertebral discs of the bovine tail

    PubMed Central

    Yu, Jing; Peter, C; Roberts, Sally; Urban, Jill PG

    2002-01-01

    Elastic fibres have been revealed by both elastin immunostaining and conventional histological orcein-staining in the intervertebral discs of the bovine tail. These fibres are distributed in all regions of the disc but their organization varies from region to region. In the centre of the nucleus, long (>150 μm) elastic fibres are orientated radially. In the transitional region between nucleus and annulus, the orientation of the elastic fibres changes, producing a criss-cross pattern. In the annulus itself, elastic fibres appear densely distributed in the region between the lamellae and also in ‘bridges’ across the lamellae, particularly in the adult. Elastic fibres are apparent within the lamellae, orientated parallel to the collagen fibres of each lamella, particularly in the young (12-day-old) discs. In the region between the disc and the cartilaginous endplate, elastic fibres appear to anchor into the plate and terminate there. The results of this study suggest that elastic fibres contribute to the mechanical functioning of the intervertebral disc. The varying organization of the elastic fibres in the different regions of the disc is likely to relate to the different regional loading patterns PMID:12489758

  9. Measuring mandibular motions

    NASA Technical Reports Server (NTRS)

    Dimeff, J.; Rositano, S.; Taylor, R. C.

    1977-01-01

    Mandibular motion along three axes is measured by three motion transducers on floating yoke that rests against mandible. System includes electronics to provide variety of outputs for data display and processing. Head frame is strapped to test subject's skull to provide fixed point of reference for transducers.

  10. 76 FR 57103 - Office of Commercial Space Transportation (AST); Notice of Availability of the Supplemental...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-15

    ..., consisting of a two-stage Castor 120 solid-propellant rocket motor with the addition of up to six Castor IVA or Castor IVXL rocket motors strapped to the first stage. The 1995 EA analyzed the potential...

  11. Non-invasive evaluation of liver stiffness after splenectomy in rabbits with CCl4-induced liver fibrosis

    PubMed Central

    Wang, Ming-Jun; Ling, Wen-Wu; Wang, Hong; Meng, Ling-Wei; Cai, He; Peng, Bing

    2016-01-01

    AIM To investigate the diagnostic performance of liver stiffness measurement (LSM) by elastography point quantification (ElastPQ) in animal models and determine the longitudinal changes in liver stiffness by ElastPQ after splenectomy at different stages of fibrosis. METHODS Liver stiffness was measured in sixty-eight rabbits with CCl4-induced liver fibrosis at different stages and eight healthy control rabbits by ElastPQ. Liver biopsies and blood samples were obtained at scheduled time points to assess liver function and degree of fibrosis. Thirty-one rabbits with complete data that underwent splenectomy at different stages of liver fibrosis were then included for dynamic monitoring of changes in liver stiffness by ElastPQ and liver function according to blood tests. RESULTS LSM by ElastPQ was significantly correlated with histologic fibrosis stage (r = 0.85, P < 0.001). The optimal cutoff values by ElastPQ were 11.27, 14.89, and 18.21 kPa for predicting minimal fibrosis, moderate fibrosis, and cirrhosis, respectively. Longitudinal monitoring of the changes in liver stiffness by ElastPQ showed that early splenectomy (especially F1) may delay liver fibrosis progression. CONCLUSION ElastPQ is an available, convenient, objective and non-invasive technique for assessing liver stiffness in rabbits with CCl4-induced liver fibrosis. In addition, liver stiffness measurements using ElastPQ can dynamically monitor the changes in liver stiffness in rabbit models, and in patients, after splenectomy. PMID:28028365

  12. WE-E-9A-01: Ultrasound Elasticity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Emelianov, S; Hall, T; Bouchard, R

    2014-06-15

    Principles and techniques of ultrasound-based elasticity imaging will be presented, including quasistatic strain imaging, shear wave elasticity imaging, and their implementations in available systems. Deeper exploration of quasistatic methods, including elastic relaxation, and their applications, advantages, artifacts and limitations will be discussed. Transient elastography based on progressive and standing shear waves will be explained in more depth, along with applications, advantages, artifacts and limitations, as will measurement of complex elastic moduli. Comparisons will be made between ultrasound radiation force techniques, MR elastography, and the simple A mode plus mechanical plunger technique. Progress in efforts, such as that by the Quantitativemore » Imaging Biomarkers Alliance, to reduce the differences in the elastic modulus reported by different commercial systems will be explained. Dr. Hall is on an Advisory Board for Siemens Ultrasound and has a research collaboration with them, including joint funding by R01CA140271 for nonlinear elasticity imaging. Learning Objectives: Be reminded of the long history of palpation of tissue elasticity for critical medical diagnosis and the relatively recent advances to be able to image tissue strain in response to an applied force. Understand the differences between shear wave speed elasticity measurement and imaging and understand the factors affecting measurement and image frame repletion rates. Understand shear wave propagation effects that can affect measurements, such as essentially lack of propagation in fluids and boundary effects, so important in thin layers. Know characteristics of available elasticity imaging phantoms, their uses and limitations. Understand thermal and cavitational limitations affecting radiation force-based shear wave imaging. Have learning and references adequate to for you to use in teaching elasticity imaging to residents and technologists. Be able to explain how elasticity measurement and imaging can contribute to diagnosis of breast and prostate cancer, staging of liver fibrosis, age estimation of deep veinous fhrombosis, confirmation of thermal lesions in the liver after RF ablation.« less

  13. Extrapolation of bulk rock elastic moduli of different rock types to high pressure conditions and comparison with texture-derived elastic moduli

    NASA Astrophysics Data System (ADS)

    Ullemeyer, Klaus; Lokajíček, Tomás; Vasin, Roman N.; Keppler, Ruth; Behrmann, Jan H.

    2018-02-01

    In this study elastic moduli of three different rock types of simple (calcite marble) and more complex (amphibolite, micaschist) mineralogical compositions were determined by modeling of elastic moduli using texture (crystallographic preferred orientation; CPO) data, experimental investigation and extrapolation. 3D models were calculated using single crystal elastic moduli, and CPO measured using time-of-flight neutron diffraction at the SKAT diffractometer in Dubna (Russia) and subsequently analyzed using Rietveld Texture Analysis. To define extrinsic factors influencing elastic behaviour, P-wave and S-wave velocity anisotropies were experimentally determined at 200, 400 and 600 MPa confining pressure. Functions describing variations of the elastic moduli with confining pressure were then used to predict elastic properties at 1000 MPa, revealing anisotropies in a supposedly crack-free medium. In the calcite marble elastic anisotropy is dominated by the CPO. Velocities continuously increase, while anisotropies decrease from measured, over extrapolated to CPO derived data. Differences in velocity patterns with sample orientation suggest that the foliation forms an important mechanical anisotropy. The amphibolite sample shows similar magnitudes of extrapolated and CPO derived velocities, however the pattern of CPO derived velocity is closer to that measured at 200 MPa. Anisotropy decreases from the extrapolated to the CPO derived data. In the micaschist, velocities are higher and anisotropies are lower in the extrapolated data, in comparison to the data from measurements at lower pressures. Generally our results show that predictions for the elastic behavior of rocks at great depths are possible based on experimental data and those computed from CPO. The elastic properties of the lower crust can, thus, be characterized with an improved degree of confidence using extrapolations. Anisotropically distributed spherical micro-pores are likely to be preserved, affecting seismic velocity distributions. Compositional variations in the polyphase rock samples do not significantly change the velocity patterns, allowing the use of RTA-derived volume percentages for the modeling of elastic moduli.

  14. Preclinical evaluation of the effect of the combined use of the Ethicon Securestrap® Open Absorbable Strap Fixation Device and Ethicon Physiomesh™ Open Flexible Composite Mesh Device on surgeon stress during ventral hernia repair

    PubMed Central

    Sutton, Nadia; MacDonald, Melinda H; Lombard, John; Ilie, Bodgan; Hinoul, Piet; Granger, Douglas A

    2018-01-01

    Aim To evaluate whether performing ventral hernia repairs using the Ethicon Physiomesh™ Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap® Open Absorbable Strap Fixation Device reduces surgical time and surgeon stress levels, compared with traditional surgical repair methods. Methods To repair a simulated ventral incisional hernia, two surgeries were performed by eight experienced surgeons using a live porcine model. One procedure involved traditional suture methods and a flat mesh, and the other procedure involved a mechanical fixation device and a skirted flexible composite mesh. A Surgery Task Load Index questionnaire was administered before and after the procedure to establish the surgeons’ perceived stress levels, and saliva samples were collected before, during, and after the surgical procedures to assess the biologically expressed stress (cortisol and salivary alpha amylase) levels. Results For mechanical fixation using the Ethicon Physiomesh Open Flexible Composite Mesh Device in conjunction with the Ethicon Securestrap Open Absorbable Strap Fixation Device, surgeons reported a 46.2% reduction in perceived workload stress. There was also a lower physiological reactivity to the intraoperative experience and the total surgical procedure time was reduced by 60.3%. Conclusions This study provides preliminary findings suggesting that the combined use of a mechanical fixation device and a skirted flexible composite mesh in an open intraperitoneal onlay mesh repair has the potential to reduce surgeon stress. Additional studies are needed to determine whether a reduction in stress is observed in a clinical setting and, if so, confirm that this results in improved clinical outcomes. PMID:29296101

  15. Quality of harness fit for normal and low birthweight infants observed among newborns in infant car seats.

    PubMed

    Brown, Julie; Sinn, John Kam Hung; Chua, Aileen; Clarke, Elizabeth Clare

    2017-04-01

    Child restraint fit is important for crash protection. For newborns, standards universally require a rear-facing restraint and some upper limit on size, but historically there has been no specification of a lower design limit and there is concern over whether low birthweight infants (LBW) are adequately restrained. The aim of this study was to determine the quality of harness fit for newborns of low and normal weight in a range of modern child restraints. A convenience sample of infants (1.657-4.455 kg) were recruited from the postnatal ward and special care nursery <1 week from discharge. Infants (n=84) were assessed for harness fit in rear-facing-only restraints, convertible rear/forward restraints and a subset were assessed in a restraint specifically designed to accommodate LBW infants. Measures of harness fit were based on shoulder strap, crotch strap and buckle positioning. Less than 20% of infants achieved good harness fit, regardless of whether they were categorised as low (<2.5 kg) or normal weight. Rear-facing-only restraints were less likely to provide good fit than convertible restraints, in all measures of fit other than shoulder strap width. The proportions of infants achieving good fit were greater in the restraint designed for LBW infants than other restraint types. Poor accommodation continues to be a problem for LBW infants but is rectified in specifically designed restraints. Better specification of harness configuration for all rearward-facing restraints may be required to ensure adequate accommodation of normal birthweight infants. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. High Voltage Test-Stand Research Done on ICRF Antenna Elements of the High-Harmonic Fast-Wave System of NSTX

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Perkins, R. J.; Ahn, J.W.; Bortolon, A.

    The twelve-strap high-harmonic fast-wave (HHFW) antenna on NSTX has exhibited a high-voltage standoff around 25 kV during previous experimental campaigns; this standoff needs to be improved for increased power coupling. During the recent NSTX-U upgrade period, a test-stand was set up with two antenna straps along with Faraday screens for testing purposes. Using a diagnostic suite consisting of a fast camera, a residual gas analyzer, a pressure gage, high-voltage probes, and an infrared camera, several interesting discoveries were made, leading to possible improvements of the antenna RF voltage operation level. First, arcing was observed outside the Faraday shields towards themore » low-voltage ("grounded") end of the straps (faraday shield box ends); this arcing was successfully eliminated by installing an additional grounding point between the Faraday shield box and the vessel wall. Second, considerable outgassing was observed during the RF pulse and the amount of outgassing was found to decrease with increasing RF power, possibly indicative of multipacting. Finally, infrared camera measurements of heating on the Faraday shield assembly suggest that the return currents on the Faraday shield box are highly localized at the box sides and possibly account for the pressure increase observed. Computations of these RF currents using Microwave Studio show qualitative agreement with the heated regions. New grounding points between the antenna box and the vessel have been implemented in NSTX-U, where future tests will be done to determine if the high-voltage standoff has improved. Further antenna improvements will be sought through future experiments on the test stand.« less

  17. Arthroscopic Talar Dome Access Using a Standard Versus Wire-Based Traction Method for Ankle Joint Distraction.

    PubMed

    Barg, Alexej; Saltzman, Charles L; Beals, Timothy C; Bachus, Kent N; Blankenhorn, Brad D; Nickisch, Florian

    2016-07-01

    To evaluate the accessibility of the talar dome through anterior and posterior portals for ankle arthroscopy with the standard noninvasive distraction versus wire-based longitudinal distraction using a tensioned wire placed transversely through the calcaneal tuberosity. Seven matched pairs of thigh-to-foot specimens underwent ankle arthroscopy with 1 of 2 methods of distraction: a standard noninvasive strapping technique or a calcaneal tuberosity wire-based technique. The order of the arthroscopic approach and use of a distraction method was randomly determined. The areas accessed from both 2-portal anterior and 2-portal posterior approaches were determined by using a molded translucent grid. The mean talar surface accessible by anterior ankle arthroscopy was comparable with noninvasive versus calcaneal wire distraction with 57.8% ± 17.2% (range, 32.9% to 75.7%) versus 61.5% ± 15.2% (range, 38.5% to 79.1%) of the talar dome, respectively (P = .590). The use of calcaneal wire distraction significantly improved posterior talar dome accessibility compared with noninvasive distraction, with 56.4% ± 20.0% (range, 14.4% to 78.0%) versus 39.8% ± 14.9% (range, 20.0% to 57.6%) of the talar dome, respectively (P = .031). Under the conditions studied, our cadaveric model showed equivalent talar dome access with 2-portal anterior arthroscopy of calcaneal wire-based distraction versus noninvasive strap distraction, but improved access for 2-portal posterior arthroscopy with calcaneal wire-based distraction versus noninvasive strap distraction. The posterior 40% of the talar dome is difficult to access via anterior ankle arthroscopy. Posterior calcaneal tuberosity wire-based longitudinal distraction improved arthroscopic access to the centro-posterior talar dome with a posterior arthroscopic approach. Published by Elsevier Inc.

  18. Conical Refraction of Elastic Waves by Anisotropic Metamaterials and Application for Parallel Translation of Elastic Waves.

    PubMed

    Ahn, Young Kwan; Lee, Hyung Jin; Kim, Yoon Young

    2017-08-30

    Conical refraction, which is quite well-known in electromagnetic waves, has not been explored well in elastic waves due to the lack of proper natural elastic media. Here, we propose and design a unique anisotropic elastic metamaterial slab that realizes conical refraction for horizontally incident longitudinal or transverse waves; the single-mode wave is split into two oblique coupled longitudinal-shear waves. As an interesting application, we carried out an experiment of parallel translation of an incident elastic wave system through the anisotropic metamaterial slab. The parallel translation can be useful for ultrasonic non-destructive testing of a system hidden by obstacles. While the parallel translation resembles light refraction through a parallel plate without angle deviation between entry and exit beams, this wave behavior cannot be achieved without the engineered metamaterial because an elastic wave incident upon a dissimilar medium is always split at different refraction angles into two different modes, longitudinal and shear.

  19. Elastic and microplastic properties of titanium in different structural states

    NASA Astrophysics Data System (ADS)

    Kardashev, B. K.; Betekhtin, V. I.; Kadomtsev, A. G.; Narykova, M. V.; Kolobov, Yu. R.

    2017-09-01

    The behavior of elastic (Young's modulus) and microplastic properties of titanium depending on the initial structure and subsequent severe plastic deformation that transforms the material (concerning the grain size) into the submicrocrystalline structural state has been studied. It has been shown that, to a great extent, different initial structures of the metal predetermine its elastic properties after deformation.

  20. Seat belt and shoulder strap use among urban travelers : interim report.

    DOT National Transportation Integrated Search

    1974-01-01

    Because of the need to establish a data baseline for belt usage without mandatory legislation, a survey of selected areas of the state of Virginia was conducted during January 1974 to determine lap and shoulder belt use by urban travelers. Observer-d...

  1. Astronaut Alan Bean participates in lunar surface simulation

    NASA Image and Video Library

    1969-10-29

    S69-56059 (24 Oct. 1969) --- Astronaut Alan L. Bean, lunar module pilot of the Apollo 12 lunar landing mission, participates in lunar surface simulation training in Building 29 at the Manned Spacecraft Center (MSC). Bean is strapped to a one-sixth gravity simulator.

  2. Automated patient monitoring system

    NASA Technical Reports Server (NTRS)

    Bedard, R. E.; Buxton, R. L.; Dawson, W. S.

    1968-01-01

    Radio-linked patient monitoring system collects several channels of physiological data from as many as 64 hospital patients and transmits the data in digital form to a central control station. The system consists of a central control station and battery-operated patient units comprising small strap-on electronics packages.

  3. Williams makes adjustment to strap in the SM during Expedition 13

    NASA Image and Video Library

    2006-04-18

    ISS013-E-08023 (18 April 2006) --- Astronaut Jeffrey N. Williams, Expedition 13 NASA space station science officer and flight engineer, prepares to exercise on the Treadmill Vibration Isolation System (TVIS) in the Zvezda Service Module of the International Space Station.

  4. STRAP PTM: Software Tool for Rapid Annotation and Differential Comparison of Protein Post-Translational Modifications.

    PubMed

    Spencer, Jean L; Bhatia, Vivek N; Whelan, Stephen A; Costello, Catherine E; McComb, Mark E

    2013-12-01

    The identification of protein post-translational modifications (PTMs) is an increasingly important component of proteomics and biomarker discovery, but very few tools exist for performing fast and easy characterization of global PTM changes and differential comparison of PTMs across groups of data obtained from liquid chromatography-tandem mass spectrometry experiments. STRAP PTM (Software Tool for Rapid Annotation of Proteins: Post-Translational Modification edition) is a program that was developed to facilitate the characterization of PTMs using spectral counting and a novel scoring algorithm to accelerate the identification of differential PTMs from complex data sets. The software facilitates multi-sample comparison by collating, scoring, and ranking PTMs and by summarizing data visually. The freely available software (beta release) installs on a PC and processes data in protXML format obtained from files parsed through the Trans-Proteomic Pipeline. The easy-to-use interface allows examination of results at protein, peptide, and PTM levels, and the overall design offers tremendous flexibility that provides proteomics insight beyond simple assignment and counting.

  5. A physical model of sensorimotor interactions during locomotion

    NASA Astrophysics Data System (ADS)

    Klein, Theresa J.; Lewis, M. Anthony

    2012-08-01

    In this paper, we describe the development of a bipedal robot that models the neuromuscular architecture of human walking. The body is based on principles derived from human muscular architecture, using muscles on straps to mimic agonist/antagonist muscle action as well as bifunctional muscles. Load sensors in the straps model Golgi tendon organs. The neural architecture is a central pattern generator (CPG) composed of a half-center oscillator combined with phase-modulated reflexes that is simulated using a spiking neural network. We show that the interaction between the reflex system, body dynamics and CPG results in a walking cycle that is entrained to the dynamics of the system. We also show that the CPG helped stabilize the gait against perturbations relative to a purely reflexive system, and compared the joint trajectories to human walking data. This robot represents a complete physical, or ‘neurorobotic’, model of the system, demonstrating the usefulness of this type of robotics research for investigating the neurophysiological processes underlying walking in humans and animals.

  6. Integrated Technology Rotor/Flight Research Rotor (ITR/FRR) concept definition study

    NASA Technical Reports Server (NTRS)

    Hughes, C. W.

    1983-01-01

    Studies were conducted by Hughes Helicopters, Inc. (HHI) for the Applied Technology Laboratory and Aeromechanics Laboratory, U.S. Army Research and Technology Laboratories (AVRADCOM) and the Ames Research Center, National Aeronautics and Space Administration (NASA). Results of predesign studies of advanced main rotor hubs, including bearingless designs, are presented in this report. In addition, the Government's rotor design goals and specifications were reviewed and evaluated. Hub concepts were designed and qualitatively evaluated in order to select the two most promising concepts for further development. Various flexure designs, control systems, and pitchcase designs were investigated during the initial phases of this study. The two designs selected for additional development were designated the V-strap and flat-strap cruciform hubs. These hubs were designed for a four bladed rotor and were sized for 18,400 pounds gross weight with the same diameter (62 feet) and solidity (23 inch chord) as the existing rotor on the Rotor Systems Research Aircraft (RSRA).

  7. HIGH FREQUENCY POWER TRANSMISSION LINE FOR CYCLOTRONS AND THE LIKE

    DOEpatents

    Armstrong, W.J.

    1954-04-20

    High-frequency power transmission systems, particularly a stacked capacitance alternating power current transmission line wherein maximum utilization of the effective conductios skin of the line conductors is achieved while enabling a low impedance to be obtained are reported. The transmission line consists of a number of flat metal strips with interleaved dielectric strips. The metal dielectric strips are coiled spirally with the axis of the spiral extending along the length of the strips, and the alternating metal strips at the output end have outwardly extending aligned lugs which are directly strapped together and connected to the respective terminals on the load. At the input end of the transmission line, similarly, the alternate metal strips are directly strapped together and connected to an altereating current source. With the arrangement described each metal strip conducts on both sides, so that the metal strips are designed to have a thickness corresponding to twice the depth of the "skin effect" conducting lamina of each conductor at the source frequency.

  8. Prediction study of structural, elastic and electronic properties of FeMP (M = Ti, Zr, Hf) compounds

    NASA Astrophysics Data System (ADS)

    Tanto, A.; Chihi, T.; Ghebouli, M. A.; Reffas, M.; Fatmi, M.; Ghebouli, B.

    2018-06-01

    First principles calculations are applied in the study of FeMP (M = Ti, Zr, Hf) compounds. We investigate the structural, elastic, mechanical and electronic properties by combining first-principles calculations with the CASTEP approach. For ideal polycrystalline FeMP (M = Ti, Zr, Hf) the shear modulus, Young's modulus, Poisson's ratio, elastic anisotropy indexes, Pugh's criterion, elastic wave velocities and Debye temperature are also calculated from the single crystal elastic constants. The shear anisotropic factors and anisotropy are obtained from the single crystal elastic constants. The Debye temperature is calculated from the average elastic wave velocity obtained from shear and bulk modulus as well as the integration of elastic wave velocities in different directions of the single crystal.

  9. Biomechanical implications of cortical elastic properties of the macaque mandible.

    PubMed

    Dechow, Paul C; Panagiotopoulou, Olga; Gharpure, Poorva

    2017-10-01

    Knowledge of the variation in the elastic properties of mandibular cortical bone is essential for modeling bone function. Our aim was to characterize the elastic properties of rhesus macaque mandibular cortical bone and compare these to the elastic properties from mandibles of dentate humans and baboons. Thirty cylindrical samples were harvested from each of six adult female rhesus monkey mandibles. Assuming orthotropy, axes of maximum stiffness in the plane of the cortical plate were derived from ultrasound velocity measurements. Further velocity measurements with longitudinal and transverse ultrasonic transducers along with measurements of bone density were used to compute three-dimensional cortical elastic properties using equations based on Hooke's law. Results showed regional variations in the elastic properties of macaque mandibular cortical bone that have both similarities and differences with that of humans and baboons. So far, the biological and structural basis of these differences is poorly understood. Copyright © 2017 Elsevier GmbH. All rights reserved.

  10. Toughening Mechanisms in Ultrahigh-Strength Steels

    DTIC Science & Technology

    1993-12-01

    coherent M2C carbide pre- cipitate with a transformation strain with three unequal eigenstrains in an elastically anisotropic AF1410 steel. The...a coherent ellipsoidal M2C carbide precipitate which has different elastic con- stants from the matrix. The eigenstrain method was used to... eigenstrain method. Here, "inhomogeneous*’ means that the elastic constants inside the precipitate are different from those of the ma- trix, and

  11. The Effect of Annealing on the Elastic Modulus of Orthodontic Wires

    NASA Astrophysics Data System (ADS)

    Higginbottom, Kyle

    Introduction: Nickel Titanium orthodontic wires are currently used in orthodontic treatment due to their heat activated properties and their delivery of constant force. The objective of this study was to determine the effect of annealing on the elastic modulus of Nickel Titanium, Stainless Steel and Beta-titanium (TMA) wires. Different points along the wire were tested in order to determine how far from the annealed ends the elastic modulus of the wires was affected. Methods: Eighty (80) orthodontic wires consisting of 4 equal groups (SS/TMA/Classic NitinolRTM/Super Elastic NitinolRTM) were used as the specimens for this study. All wires were measured and marked at 5mm measurements, and cut into 33.00mm sections. The wires were heated with a butane torch until the first 13.00mm of the wires were red hot. Load deflection tests using an InstronRTM universal testing machine were run at 5mm distances from the end of the wire that had been annealed. The change in elastic modulus was then determined. Results: There was a significant difference (F = 533.001, p = 0.0005) in the change in elastic modulus for the four distances. There was also a significant difference (F = 57.571, p = 0.0005) in the change in elastic modulus for the four wire types. There was a significant interaction (F = 19.601, p = 0.005) between wire type and distance, however this interaction negated the differences between the wires. Conclusion: 1) There are significant differences in the changes in elastic modulus between the areas of the wires within the annealed section and those areas 5mm and 10mm away from the annealed section. The change in elastic modulus within the annealed section was significantly greater at 8 mm than it was at 13mm, and this was significantly greater than 18mm and 23mm (5mm and 10mm beyond the annealed section). However, there was no statistical difference in the change in elastic modulus between 5mm and 10mm away from the annealed section (18mm and 23mm respectively). 2) Regardless of the wire type, no clinically important effects were seen 5mm and 10mm beyond the annealed portion.

  12. The magnitude of tissue cooling during cryotherapy with varied types of compression.

    PubMed

    Tomchuk, David; Rubley, Mack D; Holcomb, William R; Guadagnoli, Mark; Tarno, Jason M

    2010-01-01

    Certified athletic trainers can choose different types of external compression (none, Flex-i-Wrap, and elastic wrap) when applying an ice bag to the body. However, which type facilitates the greatest magnitude of tissue cooling is unclear. To compare the effects of 2 common types of external compression on the magnitude of surface and intramuscular cooling during an ice-bag treatment. Randomized controlled trial. University research laboratory. Fourteen college students (10 women, 4 men; age = 22.4 +/- 1.8 years, height = 169.1 +/- 8.2 cm, mass = 73.3 +/- 18.5 kg, skinfold = 13.14 +/- 1.61 mm) with previous cryotherapy experience and a posterior lower leg skinfold equal to or less than 15 mm. On 3 different days separated by 24 to 48 hours, an ice bag was applied to the posterior lower leg surface of each participant for 30 minutes with no compression, with elastic wrap, or with Flex-i-Wrap. Posterior lower leg surface and intramuscular (2 cm) temperatures were recorded for 95 minutes. At 15 minutes, the elastic wrap produced greater surface temperature reduction than no compression (P = .03); this difference remained throughout the protocol (P range, .03 to .04). At 30 minutes, surface temperatures were 14.95 degrees C, 11.55 degrees C, and 9.49 degrees C when an ice bag was applied with no external compression, Flex-i-Wrap, and elastic wrap, respectively. Surface temperatures between Flex-i-Wrap and elastic wrap and between Flex-i-Wrap and no compression were never different. At 10 minutes, Flex-i-Wrap (P = .006) and elastic wrap (P < .001) produced greater intramuscular temperature reduction than no compression produced; these differences remained throughout the protocol. At 10 minutes, no compression, Flex-i-Wrap, and elastic wrap decreased intramuscular temperature by 1.34 degrees C, 2.46 degrees C, and 2.73 degrees C, respectively. At 25 minutes, elastic wrap (8.03 degrees C) produced greater temperature reduction than Flex-i-Wrap (6.65 degrees C) (P = .03) or no compression (4.63 degrees C) (P < .001 ). These differences remained throughout ice application and until 50 minutes after ice-bag removal. During an ice-bag application, external compression with elastic wrap was more effective than Flex-i-Wrap at reducing intramuscular tissue temperature. Elastic wraps should be used for acute injury care.

  13. Influence of different surfactants on the physicochemical properties of elastic liposomes.

    PubMed

    Barbosa, R M; Severino, P; Preté, P S C; Santana, M H A

    2017-05-01

    Elastic liposomes are capable to improve drug transport through the skin by acting as penetration enhancers due to the high fluidity and elasticity of the liposome membranes. Therefore, elastic liposomes were prepared and characterized to facilitate the transdermal transport of bioactive molecules. Liposomes consisted of dimyristoylphosphatidylcholine (DMPC) as the structural component, with different surfactants derived from lauric acid as elastic components: C 12 E 5 (polyoxyethylene-5-lauryl ether), PEG4L (polyethyleneglycol-4-lauryl ester), PEG4DL (polyethylene glycol-4-dilauryl ester), PEG8L (polyethylene glycol-8-lauryl ester) and PEG8DL (polyethylene glycol-8-dilauryl ester). The elastic liposomes were characterized in terms of their phospholipid content, mean diameter, size distribution, elasticity and stability during storage, as well as their ability to incorporate surfactant and permeate through 50 nm pore size membranes. The results showed that the phospholipid phase transition temperature, the fluidity of the lipid bilayer resulting from incorporation of the surfactant and the preservation of particle integrity were factors determining the performance of the elastic liposomes in permeating through nanoporous membranes. The best results were obtained using DMPC combined with the surfactants PEG8L or PEG8DL. The findings demonstrate the potential of using elastic liposomes for transdermal administration of drugs.

  14. Development and evaluation of gas-pressurized elastic sleeves for extravehicular activity.

    PubMed

    Tanaka, Kunihiko; Tohnan, Momoka; Abe, Chikara; Iwata, Chihiro; Yamagata, Kenji; Tanaka, Masao; Tanaka, Nobuyuki; Morita, Hironobu

    2010-07-01

    In space, mobility of the current extravehicular activity space suit is limited due to the pressure differential between the inside and outside of the suit. We have previously demonstrated that an elastic glove increased mobility when compared with a non-elastic glove such as that found in the current suit. Extending this work, we hypothesized that an elastic sleeve would also have more mobility compared to a non-elastic sleeve, but a partially elastic sleeve, consisting of elastic joints sewn to non-elastic parts in low mobility areas, might generate similar mobility to a wholly elastic sleeve. The right arms of 10 volunteers were studied with wholly elastic, partially elastic, and non-elastic sleeves in a chamber pressure of -220 mmHg. Range of motion (ROM) of the wrist and electromyography (EMG) of the flexor carpi radialis muscle and the biceps brachii muscle during wrist and elbow flexion were measured. ROM of the wrist was similar among all the sleeves. However, EMG amplitudes during wrist flexion with both elastic sleeves were significantly smaller than that with the non-elastic sleeve. EMG amplitudes during 90 degrees of elbow flexion were also significantly smaller in both elastic sleeves. However, no significant difference in EMG amplitudes was observed between the two elastic sleeves (0.53 +/- 0.06, 0.56 +/- 0.07, 1.14 +/- 0.10 V for wholly elastic, partially elastic, and non-elastic sleeves, respectively). The mobility of elastic sleeves is better than that of a non-elastic sleeve. Elasticity over the joints is important; however the elasticity of the other parts does not appear to affect mobility.

  15. Application of gradient elasticity to benchmark problems of beam vibrations

    NASA Astrophysics Data System (ADS)

    Kateb, K. M.; Almitani, K. H.; Alnefaie, K. A.; Abu-Hamdeh, N. H.; Papadopoulos, P.; Askes, H.; Aifantis, E. C.

    2016-04-01

    The gradient approach, specifically gradient elasticity theory, is adopted to revisit certain typical configurations on mechanical vibrations. New results on size effects and scale-dependent behavior not captured by classical elasticity are derived, aiming at illustrating the usefulness of this approach to applications in advanced technologies. In particular, elastic prismatic straight beams in bending are discussed using two different governing equations: the gradient elasticity bending moment equation (fourth order) and the gradient elasticity deflection equation (sixth order). Different boundary/support conditions are examined. One problem considers the free vibrations of a cantilever beam loaded by an end force. A second problem is concerned with a simply supported beam disturbed by a concentrated force in the middle of the beam. Both problems are solved analytically. Exact free vibration frequencies and mode shapes are derived and presented. The difference between the gradient elasticity solution and its classical counterpart is revealed. The size ratio c/L (c denotes internal length and L is the length of the beam) induces significant effects on vibration frequencies. For both beam configurations, it turns out that as the ratio c/L increases, the vibration frequencies decrease, a fact which implies lower beam stiffness. Numerical examples show this behavior explicitly and recover the classical vibration behavior for vanishing size ratio c/L.

  16. Film thickness for different regimes of fluid-film lubrication

    NASA Technical Reports Server (NTRS)

    Hamrock, B. J.

    1980-01-01

    Film thickness equations are provided for four fluid-film lubrication regimes found in elliptical contacts. These regimes are isoviscous-rigid; viscous-rigid; elastohydrodynamic lubrication of low-elastic-modulus materials (soft EHL), or isoviscous-elastic; and elastohydrodynamic lubrication of high-elastic-modulus materials (hard EHL), or viscous-elastic. The influence or lack of influence of elastic and viscous effects is the factor that distinguishes these regimes. The results are presented as a map of the lubrication regimes, with film thickness contours on a log-log grid of the viscosity and elasticity for three values of the ellipticity parameter.

  17. Shear Elasticity and Shear Viscosity Imaging in Soft Tissue

    NASA Astrophysics Data System (ADS)

    Yang, Yiqun

    In this thesis, a new approach is introduced that provides estimates of shear elasticity and shear viscosity using time-domain measurements of shear waves in viscoelastic media. Simulations of shear wave particle displacements induced by an acoustic radiation force are accelerated significantly by a GPU. The acoustic radiation force is first calculated using the fast near field method (FNM) and the angular spectrum approach (ASA). The shear waves induced by the acoustic radiation force are then simulated in elastic and viscoelastic media using Green's functions. A parallel algorithm is developed to perform these calculations on a GPU, where the shear wave particle displacements at different observation points are calculated in parallel. The resulting speed increase enables rapid evaluation of shear waves at discrete points, in 2D planes, and for push beams with different spatial samplings and for different values of the f-number (f/#). The results of these simulations show that push beams with smaller f/# require a higher spatial sampling rate. The significant amount of acceleration achieved by this approach suggests that shear wave simulations with the Green's function approach are ideally suited for high-performance GPUs. Shear wave elasticity imaging determines the mechanical parameters of soft tissue by analyzing measured shear waves induced by an acoustic radiation force. To estimate the shear elasticity value, the widely used time-of-flight method calculates the correlation between shear wave particle velocities at adjacent lateral observation points. Although this method provides accurate estimates of the shear elasticity in purely elastic media, our experience suggests that the time-of-flight (TOF) method consistently overestimates the shear elasticity values in viscoelastic media because the combined effects of diffraction, attenuation, and dispersion are not considered. To address this problem, we have developed an approach that directly accounts for all of these effects when estimating the shear elasticity. This new approach simulates shear wave particle velocities using a Green's function-based approach for the Voigt model, where the shear elasticity and viscosity values are estimated using an optimization-based approach that compares measured shear wave particle velocities with simulated shear wave particle velocities in the time-domain. The results are evaluated on a point-by-point basis to generate images. There is good agreement between the simulated and measured shear wave particle velocities, where the new approach yields much better images of the shear elasticity and shear viscosity than the TOF method. The new estimation approach is accelerated with an approximate viscoelastic Green's function model that is evaluated with shear wave data obtained from in vivo human livers. Instead of calculating shear waves with combinations of different shear elasticities and shear viscosities, shear waves are calculated with different shear elasticities on the GPU and then convolved with a viscous loss model, which accelerates the calculation dramatically. The shear elasticity and shear viscosity values are then estimated using an optimization-based approach by minimizing the difference between measured and simulated shear wave particle velocities. Shear elasticity and shear viscosity images are generated at every spatial point in a two-dimensional (2D) field-of-view (FOV). The new approach is applied to measured shear wave data obtained from in vivo human livers, and the results show that this new approach successfully generates shear elasticity and shear viscosity images from this data. The results also indicate that the shear elasticity values estimated with this approach are significantly smaller than the values estimated with the conventional TOF method and that the new approach demonstrates more consistent values for these estimates compared with the TOF method. This experience suggests that the new method is an effective approach for estimating the shear elasticity and the shear viscosity in liver and in other soft tissue.

  18. Elastic properties of external cortical bone in the craniofacial skeleton of the rhesus monkey.

    PubMed

    Wang, Qian; Dechow, Paul C

    2006-11-01

    Knowledge of elastic properties and of their variation in the cortical bone of the craniofacial skeleton is indispensable for creating accurate finite-element models to explore the biomechanics and adaptation of the skull in primates. In this study, we measured elastic properties of the external cortex of the rhesus monkey craniofacial skeleton, using an ultrasonic technique. Twenty-eight cylindrical cortical specimens were removed from each of six craniofacial skeletons of adult Macaca mulatta. Thickness, density, and a set of longitudinal and transverse ultrasonic velocities were measured on each specimen to allow calculation of the elastic properties in three dimensions, according to equations derived from Newton's second law and Hooke's law. The axes of maximum stiffness were determined by fitting longitudinal velocities measured along the perimeter of each cortical specimen to a sinusoidal function. Results showed significant differences in elastic properties between different functional areas of the rhesus cranium, and that many sites have a consistent orientation of maximum stiffness among specimens. Overall, the cortical bones of the rhesus monkey skull can be modeled as orthotropic in many regions, and as transversely isotropic in some regions, e.g., the supraorbital region. There are differences from human crania, suggesting that structural differences in skeletal form relate to differences in cortical material properties across species. These differences also suggest that we require more comparative data on elastic properties in primate craniofacial skeletons to explore effectively the functional significance of these differences, especially when these differences are elucidated through modeling approaches, such as finite-element modeling. (c) 2006 Wiley-Liss, Inc.

  19. An experimental study of the elastic theory for granular flows

    NASA Astrophysics Data System (ADS)

    Guo, Tongtong; Campbell, Charles S.

    2016-08-01

    This paper reports annular shear cell measurements granular flows with an eye towards experimentally confirming the flow regimes laid out in the elastic theory of granular flow. Tests were carried out on four different kinds of plastic spherical particles under both constant volume flows and constant applied stress flows. In particular, observations were made of the new regime in that model, the elastic-inertial regime, and the predicted transitions between the elastic-inertial and both the elastic-quasistatic and pure inertial regimes.

  20. The Compensation Question

    ERIC Educational Resources Information Center

    Richwine, Jason; Biggs, Andrew; Mishel, Lawrence; Roy, Joydeep

    2012-01-01

    Over the past few years, as cash-strapped states and school districts have faced tough budget decisions, spending on teacher compensation has come under the microscope. The underlying question is whether, when you take everything into account, today's teachers are fairly paid, underpaid, or overpaid. In this forum, two pairs of respected…

  1. Tiedown Bracket

    NASA Technical Reports Server (NTRS)

    Mashburn, D.; Wald, J. E.; Helmsin, F. K.

    1982-01-01

    Tiedown bracket secured to concrete slab with lag anchor and lag bolt. A trailer or other heavy equipment can be anchored by tethering it to strapping bolt. When bracket is no longer needed, it can be removed, leaving behind only lag anchor. Bracket is easily installed and removed without damage to concrete slab.

  2. 10 Reasons to Flip

    ERIC Educational Resources Information Center

    Fulton, Kathleen P.

    2012-01-01

    A small school in southern Minnesota, strapped for funds and needing new math books and a fresh curriculum, flipped its classrooms and raised achievement and student engagement. The math teachers led and implemented the changes. Upon reflection, they found 10 good reasons educators should consider flipping their classroom. Among the most…

  3. 78 FR 37785 - Foreign-Trade Zone (FTZ) 196-Fort Worth, Texas; Notification of Proposed Production Activity...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-24

    ... carrying cases, wrist straps, screws, power supplies, nickel/ cadmium batteries, lithium/ion batteries, other batteries, antenna assemblies, audio flex assemblies, bridge flex assemblies, interplex assembly... components and materials sourced from abroad include: labels, battery adhesives, decals, Kevlar protective...

  4. 77 FR 26993 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-08

    ... high frequency eddy current (HFEC) inspections for cracking in holes common to the splice strap and... tasks required by this paragraph: Before further flight, do a high frequency eddy current (HFEC... approval must specifically refer to this AD. (h) Detailed and High Frequency Eddy Current Inspections...

  5. Determining the elastic properties of aptamer-ricin single molecule multiple pathway interactions

    NASA Astrophysics Data System (ADS)

    Wang, Bin; Park, Bosoon; Kwon, Yongkuk; Xu, Bingqian

    2014-05-01

    We report on the elastic properties of ricin and anti-ricin aptamer interactions, which showed three stable binding conformations, each of which has its special elastic properties. These different unbinding pathways were investigated by the dynamic force spectroscopy. A series-spring model combining the worm-like-chain model and Hook's law was used to estimate the apparent spring constants of the aptamer and linker molecule polyethylene glycol. The aptamer in its three different unbinding pathways showed different apparent spring constants. The two reaction barriers in the unbinding pathways also influence the apparent spring constant of the aptamer. This special elastic behavior of aptamer was used to distinguish its three unbinding pathways under different loading rates. This method also offered a way to distinguish and discard the non-specific interactions in single molecule experiments.

  6. Comparison of Static and Dynamic Elastic Modules of Different Strength Concretes

    NASA Astrophysics Data System (ADS)

    Uyanık, Osman; Sabbaǧ, Nevbahar

    2016-04-01

    In this study, the static and dynamic elastic (Young) modules of concrete with different strength was intended to compare. For this purpose 150mm dimensions 9 for each design cubic samples prepared and they were subjected to water cure during 28 days. After Seismic Ultrasonic P and S wave travel time measurements of samples, P and S wave velocities and taking advantage of elasticity theory the dynamic elastic modules were calculated. Concrete strength was obtained from the uniaxial compression tests in order to calculate the static elastic modules of the samples. The static elastic modulus is calculated by using the empirical relationships used in international standards. The obtained static and dynamic elastic modules have been associated. A curve was obtained from this association result that approximately similar to the stress-strain curve of obtaining at failure criterion of the sample. This study was supported with OYP05277-DR-14 Project No. by SDU and State Hydraulic Works 13th Regional/2012-01 Project No. Keywords: Concrete Strength, P and S wave Velocities, Static, Dynamic, Young Modules

  7. Morphological and biochemical studies of the elastic fibres in the craniomandibular joint articular disc of the tight-skin mouse.

    PubMed

    O'dell, N L; Burlison, S K; Starcher, B C; Pennington, C B

    1996-05-01

    The tight-skin (TSK) mouse is characterized by the hyperplasia of loose connective tissues, and of excessive growth of cartilage and of bones including the mandible. Since the fibroelastic connective tissues of the craniomandibular joint (CMJ) are essential to the functions of this joint, the present histological study compared the presence and general distribution of elastic fibres in CMJ discal tissues of TSK and normal mice. The excised CMJs were processed for light microscopy. The tissues were fixed, demineralized, embedded in paraffin, sectioned and then stained with resorcin-fuchsin to demonstrate elastic fibres. There were no obvious histological differences in either the amount or the distribution of elastic fibres in the discs from the two groups. In both groups, elastic fibres were found in the disc and in many of the attachments of the disc to the mandible and squamosal bone. In addition to the morphological preparations, articular discs and samples of lung tissue were excised from other mice and subjected to a radioimmunoassay for desmosine in order to estimate the amounts of elastin in these tissues; the amount of elastin was significantly reduced in the TSK lung, but the amounts of elastin in the TSK and normal CMJ discal tissues were not significantly different statistically. These morphological and histochemical results suggest that the distribution and quantity of elastic fibres in the TSK mouse disc are not significantly different from those in the normal mouse articular disc. Moreover, these data may be interpreted to either suggest a differential effect on the elastic fibres in different TSK tissues, or to support the suggestion that abnormal degradation of elastic fibres may not be characteristic of the TSK mouse.

  8. Endothelial, cardiac muscle and skeletal muscle exhibit different viscous and elastic properties as determined by atomic force microscopy

    NASA Technical Reports Server (NTRS)

    Mathur, A. B.; Collinsworth, A. M.; Reichert, W. M.; Kraus, W. E.; Truskey, G. A.

    2001-01-01

    This study evaluated the hypothesis that, due to functional and structural differences, the apparent elastic modulus and viscous behavior of cardiac and skeletal muscle and vascular endothelium would differ. To accurately determine the elastic modulus, the contribution of probe velocity, indentation depth, and the assumed shape of the probe were examined. Hysteresis was observed at high indentation velocities arising from viscous effects. Irreversible deformation was not observed for endothelial cells and hysteresis was negligible below 1 microm/s. For skeletal muscle and cardiac muscle cells, hysteresis was negligible below 0.25 microm/s. Viscous dissipation for endothelial and cardiac muscle cells was higher than for skeletal muscle cells. The calculated elastic modulus was most sensitive to the assumed probe geometry for the first 60 nm of indentation for the three cell types. Modeling the probe as a blunt cone-spherical cap resulted in variation in elastic modulus with indentation depth that was less than that calculated by treating the probe as a conical tip. Substrate contributions were negligible since the elastic modulus reached a steady value for indentations above 60 nm and the probe never indented more than 10% of the cell thickness. Cardiac cells were the stiffest (100.3+/-10.7 kPa), the skeletal muscle cells were intermediate (24.7+/-3.5 kPa), and the endothelial cells were the softest with a range of elastic moduli (1.4+/-0.1 to 6.8+/-0.4 kPa) depending on the location of the cell surface tested. Cardiac and skeletal muscle exhibited nonlinear elastic behavior. These passive mechanical properties are generally consistent with the function of these different cell types.

  9. Quantitative estimation of muscle shear elastic modulus of the upper trapezius with supersonic shear imaging during arm positioning.

    PubMed

    Leong, Hio-Teng; Ng, Gabriel Yin-Fat; Leung, Vivian Yee-Fong; Fu, Siu Ngor

    2013-01-01

    Pain and tenderness of the upper trapezius are the major complaints among people with chronic neck and shoulder disorders. Hyper-activation and increased muscle tension of the upper trapezius during arm elevation will cause imbalance of the scapular muscle force and contribute to neck and shoulder disorders. Assessing the elasticity of the upper trapezius in different arm positions is therefore important for identifying people at risk so as to give preventive programmes or for monitoring the effectiveness of the intervention programmes for these disorders. This study aimed to establish the reliability of supersonic shear imaging (SSI) in quantifying upper trapezius elasticity/shear elastic modulus and its ability to measure the modulation of muscle elasticity during arm elevation. Twenty-eight healthy adults (15 males, 13 females; mean age = 29.6 years) were recruited to participate in the study. In each participant, the shear elastic modulus of the upper trapezius while the arm was at rest and at 30° abduction was measured by two operators and twice by operator 1 with a time interval between the measurements. The results showed excellent within- and between-session intra-operator (ICC = 0.87-0.97) and inter-observer (ICC = 0.78-0.83) reliability for the upper trapezius elasticity with the arm at rest and at 30° abduction. An increase of 55.23% of shear elastic modulus from resting to 30° abduction was observed. Our findings demonstrate the possibilities for using SSI to quantify muscle elasticity and its potential role in delineating the modulation of upper trapezius elasticity, which is essential for future studies to compare the differences in shear elastic modulus between normal elasticity and that of individuals with neck and shoulder disorders.

  10. Quantitative Estimation of Muscle Shear Elastic Modulus of the Upper Trapezius with Supersonic Shear Imaging during Arm Positioning

    PubMed Central

    Leong, Hio-Teng; Ng, Gabriel Yin-fat; Leung, Vivian Yee-fong; Fu, Siu Ngor

    2013-01-01

    Pain and tenderness of the upper trapezius are the major complaints among people with chronic neck and shoulder disorders. Hyper-activation and increased muscle tension of the upper trapezius during arm elevation will cause imbalance of the scapular muscle force and contribute to neck and shoulder disorders. Assessing the elasticity of the upper trapezius in different arm positions is therefore important for identifying people at risk so as to give preventive programmes or for monitoring the effectiveness of the intervention programmes for these disorders. This study aimed to establish the reliability of supersonic shear imaging (SSI) in quantifying upper trapezius elasticity/shear elastic modulus and its ability to measure the modulation of muscle elasticity during arm elevation. Twenty-eight healthy adults (15 males, 13 females; mean age = 29.6 years) were recruited to participate in the study. In each participant, the shear elastic modulus of the upper trapezius while the arm was at rest and at 30° abduction was measured by two operators and twice by operator 1 with a time interval between the measurements. The results showed excellent within- and between-session intra-operator (ICC = 0.87–0.97) and inter-observer (ICC = 0.78–0.83) reliability for the upper trapezius elasticity with the arm at rest and at 30° abduction. An increase of 55.23% of shear elastic modulus from resting to 30° abduction was observed. Our findings demonstrate the possibilities for using SSI to quantify muscle elasticity and its potential role in delineating the modulation of upper trapezius elasticity, which is essential for future studies to compare the differences in shear elastic modulus between normal elasticity and that of individuals with neck and shoulder disorders. PMID:23825641

  11. The effect of antiphase boundaries on the elastic properties of Ni-Mn-Ga austenite and premartensite

    NASA Astrophysics Data System (ADS)

    Seiner, Hanuš; Sedlák, Petr; Bodnárová, Lucie; Drahokoupil, Jan; Kopecký, Vít; Kopeček, Jaromír; Landa, Michal; Heczko, Oleg

    2013-10-01

    The evolution of elastic properties with temperature and magnetic field was studied in two differently heat-treated single crystals of the Ni-Mn-Ga magnetic shape memory alloy using resonant ultrasound spectroscopy. Quenching and slow furnace cooling were used to obtain different densities of antiphase boundaries. We found that the crystals exhibited pronounced differences in the c‧ elastic coefficient and related shear damping in high-temperature ferromagnetic phases (austenite and premartensite). The difference can be ascribed to the formation of fine magnetic domain patterns and pinning of the magnetic domain walls on antiphase boundaries in the material with a high density of antiphase boundaries due to quenching. The fine domain pattern arising from mutual interactions between antiphase boundaries and ferromagnetic domain walls effectively reduces the magnetocrystalline anisotropy and amplifies the contribution of magnetostriction to the elastic response of the material. As a result, the anomalous elastic softening prior to martensite transformation is significantly enhanced in the quenched sample. Thus, for any comparison of experimental data and theoretical calculations the microstructural changes induced by specific heat treatment must be taken into account.

  12. The effect of antiphase boundaries on the elastic properties of Ni-Mn-Ga austenite and premartensite.

    PubMed

    Seiner, Hanuš; Sedlák, Petr; Bodnárová, Lucie; Drahokoupil, Jan; Kopecký, Vít; Kopeček, Jaromír; Landa, Michal; Heczko, Oleg

    2013-10-23

    The evolution of elastic properties with temperature and magnetic field was studied in two differently heat-treated single crystals of the Ni-Mn-Ga magnetic shape memory alloy using resonant ultrasound spectroscopy. Quenching and slow furnace cooling were used to obtain different densities of antiphase boundaries. We found that the crystals exhibited pronounced differences in the c' elastic coefficient and related shear damping in high-temperature ferromagnetic phases (austenite and premartensite). The difference can be ascribed to the formation of fine magnetic domain patterns and pinning of the magnetic domain walls on antiphase boundaries in the material with a high density of antiphase boundaries due to quenching. The fine domain pattern arising from mutual interactions between antiphase boundaries and ferromagnetic domain walls effectively reduces the magnetocrystalline anisotropy and amplifies the contribution of magnetostriction to the elastic response of the material. As a result, the anomalous elastic softening prior to martensite transformation is significantly enhanced in the quenched sample. Thus, for any comparison of experimental data and theoretical calculations the microstructural changes induced by specific heat treatment must be taken into account.

  13. Use of SkinFibrometer® to measure skin elasticity and its correlation with Cutometer® and DUB® Skinscanner.

    PubMed

    Kim, M A; Kim, E J; Lee, H K

    2018-02-06

    Skin elasticity is an important indicator of skin aging. The aim of this study was to demonstrate that the SkinFibrometer ® is appropriate for measuring skin biomechanical properties, and to correlate it with elasticity parameters measured using the Cutometer ® and with dermis structural properties measured using DUB ® Skinscanner. Twenty-one individuals participated in this study. The skin of the cheek, around the eye, and the volar forearm were evaluated. To analyze correlations of elasticity parameters, the induration value against the indenter pressure of SkinFibrometer ® and R, Q parameters of Cutometer ® were compared. Dermal echogenicity using DUB ® Skinscanner was compared with the induration value of SkinFibrometer ® . The younger age group showed more firm and elastic skin properties compared to the older age group, and the elasticity values of the volar forearm were significantly higher than those of the cheek and around the eye region. Even though the measuring principle is different, both SkinFibrometer ® and Cutometer ® demonstrated the same trends of skin elasticity differences according to age and anatomical regions. There were significant correlations between the induration value of SkinFibrometer ® , representing skin firmness, and R0, Q0 and R2, R5, R7, Q1, Q2 of Cutometer ® , which represent skin firmness and resilience, respectively (P < .01). In addition, dermal echogenicity positively correlated with skin firmness determined by SkinFibrometer ® (P < .01). We identified correlations between skin elasticity parameters evaluated by two different methods of suction and indentation, and demonstrated that the SkinFibrometer ® is an objective, non-invasive evaluation tool for skin stiffness and elasticity. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Tour A (Wind) Turbine - #RoundIsAShape (U.S. Department of Energy) GoPro

    ScienceCinema

    Edelman, Simon

    2018-06-12

    Get an exclusive and entertaining look inside of a wind turbine. Simon and Andy strap GoPro's to their heads and guide you as they travel 270 feet up to the top of a turbine at the National Wind Technology Center in Golden, CO.

  15. Strapping in and Bailing out: Navy and Air Force Joint Acquisition of Aircraft

    DTIC Science & Technology

    2002-06-01

    Secretary of the Air Force and the Secretary of Defense were not pleased with the attempted shenanigans . With the rarely invoked contractor review...December 14, 1990. Tarascio, Colonel John R., Director of Budget & Appropriations Liaison, Assistant Secretary of the Air Force ( Financial Management

  16. 29 CFR 1926.951 - Tools and protective equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... falling objects, electric shock, or burns. (b) Personal climbing equipment. (1) Body belts with straps or...) Be equipped with three-wire cord having the ground wire permanently connected to the tool frame and... “Double Insulated”; or (iii) Be connected to the power supply by means of an isolating transformer, or...

  17. 78 FR 9793 - Airworthiness Directives; Bell Helicopter Textron Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-12

    ...-numbered main rotor hub inboard strap fittings (fittings). This AD requires magnetic particle inspecting..., data, or views. We also invite comments relating to the economic, environmental, energy, or federalism..., perform a magnetic particle inspection (MPI) of each fitting for a crack. If an MPI was already performed...

  18. Tracheal invasion by Thyroid nodule in Thyroidectomy

    DTIC Science & Technology

    2017-10-20

    through the first tracheal ring. The tracheal defect was fixed with a strap muscle flap and surgery concluded uneventfully. Following deep extubation, an...air leak at the surgical site was noted. The patient was reintubated, the incision was re-opened and the tracheal flap was revised to prevent tracheal leaking.

  19. Profit and Loss in School-Business Partnerships

    ERIC Educational Resources Information Center

    Hann, Leslie Werstein

    2008-01-01

    From national initiatives that aim to broadly reform education to local efforts to pair children with tutors, corporations are increasingly involved with schools. The idea of business-school relationships is not new. However, the confluence of several powerful currents--corporate advocacy on education policy, cash-strapped public schools,…

  20. 77 FR 7011 - Safety Standard for Infant Swings

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-10

    ... JPMA as compliant with the ASTM voluntary infant swing standard. C. Infant Swings and the ASTM... positioned in the swing seat. c. Description of Proposed Changes The shoulder strap requirement is intended... swing fails the test. c. Description of Proposed Changes The proposed rule would make two changes to the...

  1. 5. Photograph of a photograph in possession of Rock Island ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Photograph of a photograph in possession of Rock Island Arsenal Historical Office. EAST AND NORTH ELEVATIONS BEFORE REMOVAL OF STRAP-HINGE DOOR. DATED NOVEMBER 21, 1944. - Rock Island Arsenal, Building No. 139, Second Street between Ramsey Street & South Avenue, Rock Island, Rock Island County, IL

  2. 5. Photograph of a photograph in possession of Rock Island ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    5. Photograph of a photograph in possession of Rock Island Arsenal Historical Office. WEST AND SOUTH ELEVATIONS BEFORE REPLACEMENT OF STRAP-HINGE DOOR. DATED NOVEMBER 1, 1944. - Rock Island Arsenal, Building No. 140, Second Street between Ramsey Street & South Avenue, Rock Island, Rock Island County, IL

  3. 77 FR 60889 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-05

    ... repetitive inspections for cracks and a chemical spot test in the area of station (STA) 908, and related... FR 32918). That NPRM proposed to require repetitive inspections for cracks and a chemical spot test... inspection, repetitive inspections, and chemical spot test requirements, by replacing the butt strap with a...

  4. Seat belt and shoulder strap use among urban travelers : a comparison of survey results from 1974, 1975, and 1976.

    DOT National Transportation Integrated Search

    1977-01-01

    During nine days in late January 1974, four major metropolitan areas of the state of Virginia were surveyed in an effort to determine seat belt use by urban travelers. Observer-data collectors were stationed at selected signalized intersections. Moto...

  5. Seat belt and shoulder strap use among urban travelers : results of the summer 1977 survey : a report.

    DOT National Transportation Integrated Search

    1978-01-01

    During nine days in June 1977, four major metropolitan areas of the state of Virginia were surveyed to determine seat belt use by summer urban travelers. Observer-data collectors were stationed at selected signalized intersections. Motorists in the l...

  6. Seat belt and shoulder strap use among urban travelers : a comparison of results from 1974 and 1975 surveys : a report.

    DOT National Transportation Integrated Search

    1976-01-01

    During nine consecutive days in late January 1974, four major metropolitan areas of the state of Virginia were surveyed in an effort to determine seat belt use by urban travelers. Observer data collectors were stationed at selected signalized interse...

  7. 46 CFR 164.019-7 - Non-standard components; acceptance criteria and procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...) Inner Envelope Fabric; (iv) Closure (including zippers) or Adjustment Hardware; (v) Body Strap; (vi... in detail and including the unique style, part, or model number, the identification data required by the applicable subpart of this part, and any other manufacturer's identifying data. No two components...

  8. 46 CFR 164.019-7 - Non-standard components; acceptance criteria and procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...) Inner Envelope Fabric; (iv) Closure (including zippers) or Adjustment Hardware; (v) Body Strap; (vi... in detail and including the unique style, part, or model number, the identification data required by the applicable subpart of this part, and any other manufacturer's identifying data. No two components...

  9. 46 CFR 164.019-7 - Non-standard components; acceptance criteria and procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ...) Inner Envelope Fabric; (iv) Closure (including zippers) or Adjustment Hardware; (v) Body Strap; (vi... in detail and including the unique style, part, or model number, the identification data required by the applicable subpart of this part, and any other manufacturer's identifying data. No two components...

  10. Therapeutic hand-exercising device with cycling pressure value

    NASA Technical Reports Server (NTRS)

    Barthlome, D. E.

    1974-01-01

    Device exercises hands of persons whose fingers are generally straight and need to be flexed inward toward palms of hands. Device is extremely simple in design, which reduces costs, and fits all hand sizes. Patient can instantly free hand from device by pulling flap free from wrist of straps.

  11. Seven Red Herrings: The Opposition to Closure of Aging Urban Schools.

    ERIC Educational Resources Information Center

    McLean, Russ

    2003-01-01

    Considers how the closure and consolidation of schools are seen by cash-strapped boards of education as means to save money. Addresses the same "seven red herrings" or arguments that are repeated loudly and angrily to officials as they go through the process of public consultation. (SG)

  12. 14 CFR 27.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... occupant properly uses the seats, safety belts, and shoulder harnesses provided in the design; and (2) The... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact, although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  13. 14 CFR 27.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... occupant properly uses the seats, safety belts, and shoulder harnesses provided in the design; and (2) The... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact, although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  14. 14 CFR 29.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... the seats, safety belts, and shoulder harnesses provided in the design; and (2) The occupant is... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  15. 14 CFR 27.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... occupant properly uses the seats, safety belts, and shoulder harnesses provided in the design; and (2) The... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact, although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  16. 14 CFR 27.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... occupant properly uses the seats, safety belts, and shoulder harnesses provided in the design; and (2) The... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact, although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  17. 14 CFR 29.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... the seats, safety belts, and shoulder harnesses provided in the design; and (2) The occupant is... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  18. 14 CFR 29.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... the seats, safety belts, and shoulder harnesses provided in the design; and (2) The occupant is... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  19. 14 CFR 29.562 - Emergency landing dynamic conditions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... the seats, safety belts, and shoulder harnesses provided in the design; and (2) The occupant is... would cause the greatest load on the shoulder harness), the rotorcraft's lateral axis is contained in a... intact although the structure may have exceeded its limit load. (3) The ATD's shoulder harness strap or...

  20. Cash-Strapped Canadian Universities Seek New Ways To Bring in Money.

    ERIC Educational Resources Information Center

    Lewington, Jennifer

    1997-01-01

    Struggling to manage under reduced public financial support, many of Canada's universities are turning to entrepreneurial projects to provide supplemental income. In addition to conventional means such as real estate development, investment, and marketing, some are shifting ancillary services (conference facilities, residences, food services,…

  1. Young, Black, Mathematically Gifted, and Stereotyped

    ERIC Educational Resources Information Center

    McGee, Ebony

    2013-01-01

    In this paper, I describe the academic dilemma experienced by Tamara (pseudonym), a mathematically high-achieving high school sophomore. Raised in an economically strapped neighborhood, Tamara had the opportunity to attend a prestigious private high school, tuition free. Confronted by being viewed as an affirmative action student Tamara uses this…

  2. 49 CFR 393.7 - Matter incorporated by reference.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., Society of Automotive Engineers (SAE) J581, July 2004, incorporation by reference approved for § 393.24(b... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications...

  3. 49 CFR 393.7 - Matter incorporated by reference.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ..., Society of Automotive Engineers (SAE) J581, July 2004, incorporation by reference approved for § 393.24(b... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications...

  4. 49 CFR 393.7 - Matter incorporated by reference.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ..., Society of Automotive Engineers (SAE) J581, July 2004, incorporation by reference approved for § 393.24(b... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications...

  5. Stunning Swarms: An Airpower Alternative to Collateral Damage

    DTIC Science & Technology

    2010-04-01

    approach. A recent example is the Russian rescue of over 700 hostages from Chechen rebels in 2002. 31 Strapped into suicide vests, the rebels took 800...fentanils (or fentanyls ), and could be modified (e.g., with ethyl groups) to produce a less powerful compound that is more tailored to human use

  6. Loss of Veterans Doesn't Hurt Scores

    ERIC Educational Resources Information Center

    Sparks, Sarah D.

    2013-01-01

    Boosting early retirement in cash-strapped districts does not hurt students' math and reading scores, according to new studies released at the American Economic Association meeting, but pension-incentive programs may cost schools some of their most effective teachers. Separate studies of teachers in California, Illinois, and North Carolina paint a…

  7. Pilot Fullerton dons ejection escape suit (EES) on middeck

    NASA Image and Video Library

    1982-03-30

    STS003-23-165 (22-30 March 1982) --- Astronaut Gordon Fullerton, STS-3 pilot, dons ejection escape suit (EES) (high altitude pressure garment) life preserver unit (LPU) on forward port side of middeck above potable water tank. Fullerton also adjusts lapbelt fitting and helmet holddown strap. Photo credit: NASA

  8. 21 CFR 886.1500 - Headband mirror.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... DEVICES OPHTHALMIC DEVICES Diagnostic Devices § 886.1500 Headband mirror. (a) Identification. A headband mirror is a device intended to be strapped to the head of the user to reflect light for use in examination of the eye. (b) Classification. Class I (general controls). The device is exempt from the...

  9. Investing in High School

    ERIC Educational Resources Information Center

    Green, Daniel G.

    2012-01-01

    Strapped for cash, a Massachusetts high school creates its own venture capital fund to incentivize teachers to create programs that improve student learning. The result has been higher test scores and higher job satisfaction. One important program is credited with helping close the achievement gap at the school, while others have helped ambitious…

  10. 50 CFR 660.130 - Trawl fishery-management measures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... “skirt”) may encircle the net under transfer cables, lifting or splitting straps (chokers), but must be... board, either simultaneously or successively, at any time during a cumulative limit period, then the... of small footrope gear onboard the vessel at any time during the cumulative limit period, the most...

  11. 50 CFR 660.130 - Trawl fishery-management measures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... “skirt”) may encircle the net under transfer cables, lifting or splitting straps (chokers), but must be... board, either simultaneously or successively, at any time during a cumulative limit period, then the... of small footrope gear onboard the vessel at any time during the cumulative limit period, the most...

  12. A Full Plate for Schools.

    ERIC Educational Resources Information Center

    Marlowe, John

    2002-01-01

    As of summer 2001, at least 12 states are deep-sixing junk foods in schools. Schools face an uphill battle on nutrition education. Commercials promoting junk food seem ubiquitous, and children are spending too many inactive hours watching television. Major challenges include the open-campus lunch period and cash-strapped schools using profits from…

  13. Thermoelastic Damping in FGM Nano-Electromechanical System in Axial Vibration Based on Eringen Nonlocal Theory

    NASA Astrophysics Data System (ADS)

    Rahimi, Z.; Rashahmadi, S.

    2017-11-01

    The thermo-elastic damping is a dominant source of internal damping in micro-electromechanical systems (MEMS) and nano-electromechanical systems (NEMS). The internal damping cannot neither be controlled nor minimized unless either mechanical or geometrical properties are changed. Therefore, a novel FGMNEM system with a controllable thermo-elastic damping of axial vibration based on Eringen nonlocal theory is considered. The effects of different parameter like the gradient index, nonlocal parameter, length of nanobeam and ambient temperature on the thermo-elastic damping quality factor are presented. It is shown that the thermo-elastic damping can be controlled by changing different parameter.

  14. Quasi-periodic oscillations in superfluid, relativistic magnetars with nuclear pasta phases

    NASA Astrophysics Data System (ADS)

    Passamonti, Andrea; Pons, José A.

    2016-12-01

    We study the torsional magneto-elastic oscillations of relativistic superfluid magnetars and explore the effects of a phase transition in the crust-core interface (nuclear pasta) which results in a weaker elastic response. Exploring various models with different extension of nuclear pasta phases, we find that the differences in the oscillation spectrum present in purely elastic modes (weak magnetic field) are smeared out with increasing strength of the magnetic field. For magnetar conditions, the main characteristic and features of models without nuclear pasta are preserved. We find, in general, two classes of magneto-elastic oscillations which exhibit a different oscillation pattern. For Bp < 4 × 1014 G, the spectrum is characterized by the turning points and edges of the continuum which are mostly confined into the star's core, and have no constant phase. Increasing the magnetic field, we find, in addition, several magneto-elastic oscillations which reach the surface and have an angular structure similar to crustal modes. These global magneto-elastic oscillations show a constant phase and become dominant when Bp > 5 × 1014 G. We do not find any evidence of fundamental pure crustal modes in the low-frequency range (below 200 Hz) for Bp ≥ 1014 G.

  15. Revisit of the relationship between the elastic properties and sound velocities at high pressures

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Chenju; Yan, Xiaozhen; Institute of Atomic and Molecular Sciences, Sichuan University, Chengdu 610065

    2014-09-14

    The second-order elastic constants and stress-strain coefficients are defined, respectively, as the second derivatives of the total energy and the first derivative of the stress with respect to strain. Since the Lagrangian and infinitesimal strain are commonly used in the two definitions above, the second-order elastic constants and stress-strain coefficients are separated into two categories, respectively. In general, any of the four physical quantities is employed to characterize the elastic properties of materials without differentiation. Nevertheless, differences may exist among them at non-zero pressures, especially high pressures. Having explored the confusing issue systemically in the present work, we find thatmore » the four quantities are indeed different from each other at high pressures and these differences depend on the initial stress applied on materials. Moreover, the various relations between the four quantities depicting elastic properties of materials and high-pressure sound velocities are also derived from the elastic wave equations. As examples, we calculated the high-pressure sound velocities of cubic tantalum and hexagonal rhenium using these nexus. The excellent agreement of our results with available experimental data suggests the general applicability of the relations.« less

  16. Hydrodynamic and elastic interactions of sedimenting flexible fibers

    NASA Astrophysics Data System (ADS)

    Ekiel-Jezewska, Maria L.; Bukowicki, Marek

    2017-11-01

    Dynamics of flexible micro and nano filaments in fluids is intensively investigated in many laboratories, with a perspective of numerous applications in biology, medicine or modern technology. In the literature, different theoretical models of elastic interactions between flexible fiber segments are applied. The task of this work is to examine the impact of a chosen elastic model on the dynamics of fibers settling in a viscous fluid under low Reynolds number. To this goal, we construct two trumbbells, each made of three beads connected by springs and with a bending resistance, and we describe hydrodynamic interactions of the beads in terms of the Rotne-Prager mobility tensors. Using the harmonic bending potential, and coupling it to the spring potential by the Young's modulus, we find simple benchmark solutions: stable stationary configurations of a single elastic trumbbell and a fast horizontal attraction of two elastic trumbbells towards a periodic long-lasting orbit. We show that for sufficiently large bending angles, other models of bending interactions can lead to qualitatively and quantitatively different spurious effects. We also demonstrate examples of essential differences between the dynamics of elastic dumbbells and trumbbells. This work was supported in part by Narodowe Centrum Nauki under Grant No. 2014/15/B/ST8/04359.

  17. Efficient Thermally Conductive Strap Design for Cryogenic Propellant Tank Supports and Plumbing

    NASA Technical Reports Server (NTRS)

    Elchert, J. P.; Christie, R.; Kashani, A.; Opalach, C.

    2012-01-01

    After evaluating NASA space architecture goals, the Office of Chief Technologist identified the need for developing enabling technology for long term loiters in space with cryogenic fluids. One such technology is structural heat interception. In this prototype, heat interception at the tank support strut was accomplished using a thermally conductive link to the broad area cooled shield. The design methodology for both locating the heat intercept and predicting the reduction in boil-off heat leak is discussed in detail. Results from the chosen design are presented. It was found that contact resistance resulting from different mechanical attachment techniques played a significant role in the form and functionality of a successful design.

  18. Efficient Thermally Conductive Strap Design for Cryogenic Propellant Tank Supports and Plumbing

    NASA Technical Reports Server (NTRS)

    Elchert, J. P.; Christie, R.; Gebby, P.; Kashani, A.

    2012-01-01

    After evalu1ating NASA space architecture goals, the Office of Chief Technologist identified the need for developing enabling technology for long term loiters in space with cryogenic fluids. One such technology is structural heat interception. In this prototype, heat interception at the tank support strut was accomplished using a thermally conductive link to the broad area cooled shield. The design methodology for both locating the heat intercept and predicting the reduction in boil-off heat leak is discussed in detail. Results from the chosen design are presented. It was found that contact resistance resulting from different mechanical attachment techniques played a significant role in the form and functionality of a successful design.

  19. Speech Research

    NASA Astrophysics Data System (ADS)

    Several articles addressing topics in speech research are presented. The topics include: exploring the functional significance of physiological tremor: A biospectroscopic approach; differences between experienced and inexperienced listeners to deaf speech; a language-oriented view of reading and its disabilities; Phonetic factors in letter detection; categorical perception; Short-term recall by deaf signers of American sign language; a common basis for auditory sensory storage in perception and immediate memory; phonological awareness and verbal short-term memory; initiation versus execution time during manual and oral counting by stutterers; trading relations in the perception of speech by five-year-old children; the role of the strap muscles in pitch lowering; phonetic validation of distinctive features; consonants and syllable boundaires; and vowel information in postvocalic frictions.

  20. In search of a corrected prescription drug elasticity estimate: a meta-regression approach.

    PubMed

    Gemmill, Marin C; Costa-Font, Joan; McGuire, Alistair

    2007-06-01

    An understanding of the relationship between cost sharing and drug consumption depends on consistent and unbiased price elasticity estimates. However, there is wide heterogeneity among studies, which constrains the applicability of elasticity estimates for empirical purposes and policy simulation. This paper attempts to provide a corrected measure of the drug price elasticity by employing meta-regression analysis (MRA). The results indicate that the elasticity estimates are significantly different from zero, and the corrected elasticity is -0.209 when the results are made robust to heteroskedasticity and clustering of observations. Elasticity values are higher when the study was published in an economic journal, when the study employed a greater number of observations, and when the study used aggregate data. Elasticity estimates are lower when the institutional setting was a tax-based health insurance system.

  1. Elasticity of human embryonic stem cells as determined by atomic force microscopy.

    PubMed

    Kiss, Robert; Bock, Henry; Pells, Steve; Canetta, Elisabetta; Adya, Ashok K; Moore, Andrew J; De Sousa, Paul; Willoughby, Nicholas A

    2011-10-01

    The expansive growth and differentiation potential of human embryonic stem cells (hESCs) make them a promising source of cells for regenerative medicine. However, this promise is off set by the propensity for spontaneous or uncontrolled differentiation to result in heterogeneous cell populations. Cell elasticity has recently been shown to characterize particular cell phenotypes, with undifferentiated and differentiated cells sometimes showing significant differences in their elasticities. In this study, we determined the Young's modulus of hESCs by atomic force microscopy using a pyramidal tip. Using this method we are able to take point measurements of elasticity at multiple locations on a single cell, allowing local variations due to cell structure to be identified. We found considerable differences in the elasticity of the analyzed hESCs, reflected by a broad range of Young's modulus (0.05-10 kPa). This surprisingly high variation suggests that elasticity could serve as the basis of a simple and efficient large scale purification/separation technique to discriminate subpopulations of hESCs.

  2. Association Between Scalp Laxity, Elasticity, and Glidability and Donor Strip Scar Width in Hair Transplantation and a New Elasticity Measuring Method.

    PubMed

    Park, Jae Hyun

    2017-04-01

    Hair transplantation requires precise evaluation of donor site laxity, elasticity, and glidability. The purpose of this study was to examine the relationship between donor strip scar width and preoperative laxity, elasticity, and glidability. Preoperative measurements of scalp laxity, elasticity, and glidability and of donor site scar width 10 months postoperatively were evaluated in 88 patients who underwent hair transplantation with strip harvesting. Elasticity was measured by firmly pressing the scalp with the fingertips of one hand at 2 points to restrict dermis movement while stretching the skin with the other hand. Glidability was calculated as laxity minus elasticity. Scar width positively correlated with laxity (p < .01) and elasticity (p < .05) but had no relationship with glidability. There was a significant difference between patients in the upper 30th percentile of elasticity (≥10 mm) versus others (<10 mm) in scar width. Scalp laxity, elasticity, and glidability are of great clinical importance in hair transplantation. The authors' novel method of measuring elasticity will assist surgeons in predicting donor site scar width.

  3. The ultra-structural organization of the elastic network in the intra- and inter-lamellar matrix of the intervertebral disc.

    PubMed

    Tavakoli, J; Elliott, D M; Costi, J J

    2017-08-01

    The inter-lamellar matrix (ILM)-located between adjacent lamellae of the annulus fibrosus-consists of a complex structure of elastic fibers, while elastic fibers of the intra-lamellar region are aligned predominantly parallel to the collagen fibers. The organization of elastic fibers under low magnification, in both inter- and intra-lamellar regions, was studied by light microscopic analysis of histologically prepared samples; however, little is known about their ultrastructure. An ultrastructural visualization of elastic fibers in the inter-lamellar matrix is crucial for describing their contribution to structural integrity, as well as mechanical properties of the annulus fibrosus. The aims of this study were twofold: first, to present an ultrastructural analysis of the elastic fiber network in the ILM and intra-lamellar region, including cross section (CS) and in-plane (IP) lamellae, of the AF using Scanning Electron Microscopy (SEM) and second, to -compare the elastic fiber orientation between the ILM and intra-lamellar region. Four samples (lumbar sheep discs) from adjacent sections (30μm thickness) of anterior annulus were partially digested by a developed NaOH-sonication method for visualization of elastic fibers by SEM. Elastic fiber orientation and distribution were quantified relative to the tangential to circumferential reference axis. Visualization of the ILM under high magnification revealed a dense network of elastic fibers that has not been previously described. Within the ILM, elastic fibers form a complex network, consisting of different size and shape fibers, which differed to those located in the intra-lamellar region. For both regions, the majority of fibers were oriented near 0° with respect to tangential to circumferential (TCD) direction and two minor symmetrical orientations of approximately±45°. Statistically, the orientation of elastic fibers between the ILM and intra-lamellar region was not different (p=0.171). The present study used extracellular matrix partial digestion to address significant gaps in understanding of disc microstructure and will contribute to multidisciplinary ultrastructure-function studies. Visualization of the intra-lamellar matrix under high magnification revealed a dense network of elastic fibers that has not been previously described. The present study used extracellular matrix partial digestion to address significant gaps in understanding of disc microstructure and will contribute to multidisciplinary ultrastructure-function studies. Copyright © 2017 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  4. Nano-Bio-Mechanics of Neuroblastoma Cells Using AFM

    NASA Astrophysics Data System (ADS)

    Bastatas, Lyndon; Matthews, James; Kang, Min; Park, Soyeun

    2011-10-01

    We have conducted an in vitro study to determine the elastic moduli of neurobalstoma cell lines using atomic force microscopy. Using a panel of cell lines established from neuroblastoma patients at different stages of disease progress and treatment, we have investigated the differences in elastic moduli during a course of cancer progression and chemotherapy. The cells were grown on the hard substrates that are chemically functionalized to enhance adhesion. We have performed the AFM indentation experiments with different applied forces from the AFM probe. For the purpose of the comparison between cell lines, the indentations were performed only on cell centers. The obtained force-distance curves were analyzed using the Hertz model in order to extract the elastic moduli. We have found that the elastic moduli of human neuroblastoma cells significantly varied during the disease progression. We postulate that the observed difference might be affected by the treatment and chemotherapy.

  5. Adaptive elastic metasurfaces for wave front manipulation

    NASA Astrophysics Data System (ADS)

    Li, Shilong; Xu, Jiawen; Tang, Jiong

    2018-04-01

    In this research, by combining the concept of elastic metasurfaces with piezoelectric transducer with shunted circuitry, we investigate the designs of elastic metasurfaces, consisting of an array of piezoelectric transducers shunted with negative capacitance, which is capable of modulating wave fronts adaptively. In order to construct different adaptive elastic metasurfaces, different phase profiles along the interface can be framed through properly adjusting the negative capacitance values. Flat planar lenses for focusing transmitted A0 Lamb waves are achieved, and possess the flexibility of changing focal locations through electromechanical tunings. Additionally, nonparaxial self-bending beams with arbitrary trajectories and source illusion devices can also be accomplished owing to the free manipulation of phase shifts. With their versatility and tunability, the adaptive elastic metasurfaces could pave new avenues to a wide variety of potential applications, such as nondestructive testing, ultrasound imaging, and caustic engineering.

  6. Synergic effect of salivary pH baselines and low pH intakes on the force relaxation of orthodontic latex elastics.

    PubMed

    Ajami, Shabnam; Farjood, Amin; Zare, Mahbubeh

    2017-01-01

    Latex elastics are still in common use due to their low cost and high flexibility to improve sagittal discrepancies or interdigitation of teeth. Mechanical properties of elastics are influenced by several environmental factors such as pH changes. This study evaluated similar latex elastics to define the influence of synergic effect of intermittent low pH and various baselines pH of saliva. Four groups of latex elastics (3-M Unitek, 3/16 inch) were tested ( n = 15 in each group). Two groups of elastics were immersed in two tanks of artificial saliva with different pH levels of 7 and 5, and two groups were immersed in two tanks of artificial saliva with intermittent drop of pH to 4. The force was measured when the elastics were stretched to 25 mm. These measurements were taken in 0, 4, 8, 12, 24, 36, and 48 h for each group. Repeated measures analysis of variance (RMANOVA) and post-hoc Tukey's test were used to assess the findings. The level of significance was 0.05%. The interaction between pH and time analyzed with RMANOVA showed no significant differences ( P > 0.05) except in 36 h ( P = 0.014). The Tukey's analysis showed that each comparison between any two groups did not indicate significant differences ( P > 0.05) except between Groups 1 and 3 and between Groups 2 and 3 ( P < 0.05). No significant correlation was seen between fluctuation of pH and force degradation in latex elastic band except in 36 h.

  7. Comparison of formation of visco-elastic masses and their properties between zeins and kafirins.

    PubMed

    Taylor, Janet; Anyango, Joseph O; Muhiwa, Peter J; Oguntoyinbo, Segun I; Taylor, John R N

    2018-04-15

    Zeins of differing sub-class composition much more readily formed visco-elastic masses in water or acetic acid solutions than equivalent kafirin preparations. Visco-elastic masses could be formed from both zein and kafirin preparations by coacervation from glacial acetic acid. Dissolving the prolamins in glacial acetic acid apparently enabled protonation and complete solvation. Stress-relaxation analysis of coacervated zein and kafirin visco-elastic masses showed they were initially soft. With storage, they became much firmer. Zein masses exhibited predominantly viscous flow properties, whereas kafirin masses were more elastic. The γ-sub-class is apparently necessary for the retention of visco-elastic mass softness with kafirin and zein, and for elastic recovery of kafirin. Generally, regardless of water or acetic acid treatment, all the zein preparations had similar FTIR spectra, with greater α-helical conformation, than the kafirin preparations which were also similar to each other. Kafirin visco-elastic masses have a much higher elastic character than zein masses. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Accidental death due to complete autoerotic asphyxia associated with transvestic fetishism and anal self-stimulation - case report.

    PubMed

    Atanasijević, Tatjana; Jovanović, Aleksandar A; Nikolić, Slobodan; Popović, Vesna; Jasović-Gasić, Miroslava

    2009-06-01

    A case is reported of a 36-year-old male, found dead in his locked room, lying on a bed, dressed in his mother's clothes, with a plastic bag over his head, hands tied and with a barrel wooden cork in his rectum. Two pornographic magazines were found on a chair near the bed, so that the deceased could see them well. Asphyxia was controlled with a complex apparatus which consisted of two elastic luggage rack straps, the first surrounding his waist, perineum, and buttocks, and the second the back of his body, and neck. According to the psychological autopsy based on a structured interview (SCID-I, SCID-II) with his father, the deceased was single, unemployed and with a part college education. He had grown up in a poor family with a reserved father and dominant mother, and was indicative of fulfilling DSM-IV diagnostic criteria for alcohol dependence, paraphilia involving hypoxyphilia with transvestic fetishism and anal masturbation and a borderline personality disorder. There was no evidence of previous psychiatric treatment. The Circumstances subscale of Beck's Suicidal Intent Scale (SIS-CS) pointed at the lack of final acts (thoughts or plans) in anticipation of death, and absence of a suicide note or overt communication of suicidal intent before death. Integration of the crime scene data with those of the forensic medicine and psychological autopsy enabled identification of the event as an accidental death, caused by neck strangulation, suffocation by a plastic bag, and vagal stimulation due to a foreign body in the rectum.

  9. 49 CFR 571.225 - Standard No. 225; Child restraint anchorage systems.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... N of preload prior to the test. The strap is fitted at one end with a high strength steel tether... systems to ensure their proper location and strength for the effective securing of child restraints, to... manufactured on or after September 1, 1999, shall comply with the configuration, location, marking and strength...

  10. Commander Brand stows trash in jettison bag on middeck

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Commander Brand disposes of empty food containers and dry trash in jettison bag and stows bag in middeck volume under MA73C control panel. Side hatch is visible behind Brand. Brand is wearing constant wear garment with communications kit assembly headset interface unit (HIU) and note pad strapped to his thighs.

  11. 29 CFR 1926.450 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... means a single-point adjustable suspension scaffold consisting of a seat or sling designed to support... means a design of straps which may be secured about the employee in a manner to distribute the fall... a series of interconnected braced scaffold members or supporting structures erected to form a...

  12. 29 CFR 1926.450 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... means a single-point adjustable suspension scaffold consisting of a seat or sling designed to support... means a design of straps which may be secured about the employee in a manner to distribute the fall... a series of interconnected braced scaffold members or supporting structures erected to form a...

  13. 29 CFR 1926.450 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... means a single-point adjustable suspension scaffold consisting of a seat or sling designed to support... means a design of straps which may be secured about the employee in a manner to distribute the fall... a series of interconnected braced scaffold members or supporting structures erected to form a...

  14. 29 CFR 1926.450 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... means a single-point adjustable suspension scaffold consisting of a seat or sling designed to support... means a design of straps which may be secured about the employee in a manner to distribute the fall... a series of interconnected braced scaffold members or supporting structures erected to form a...

  15. Debt and Graduation from American Universities

    ERIC Educational Resources Information Center

    Dwyer, Rachel E.; McCloud, Laura; Hodson, Randy

    2012-01-01

    The goal of "college-for-all" in the United States has been pursued in an environment of rising tuition, stagnant grant aid and already strapped family budgets with the gap filled by college loans. College students are thus facing increasing levels of debt as they seek to develop their human capital and improve their career options. Debt…

  16. 49 CFR 173.156 - Exceptions for limited quantity and ORM.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ..., carts, boxes or similar overpacks; (ii) Offered for transportation or transported by: (A) Rail; (B... transported to a disposal facility from one offeror. (2) The 30 kg (66 pounds) gross weight limitation does... a fiberboard box which is banded and secured to a wooden pallet by metal, fabric, or plastic straps...

  17. 29 CFR Appendix B to Subpart I to... - Non-mandatory Compliance Guidelines for Hazard Assessment and Personal Protective Equipment...

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... work operations. In some cases a chin strap may be necessary to keep the helmet on an employee's head..., grinding machining, masonry work, woodworking, sawing, drilling, chiseling, powered fastening, riveting...

  18. 29 CFR Appendix B to Subpart I of... - Non-mandatory Compliance Guidelines for Hazard Assessment and Personal Protective Equipment...

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... work operations. In some cases a chin strap may be necessary to keep the helmet on an employee's head..., grinding machining, masonry work, woodworking, sawing, drilling, chiseling, powered fastening, riveting...

  19. 29 CFR Appendix B to Subpart I to... - Non-mandatory Compliance Guidelines for Hazard Assessment and Personal Protective Equipment...

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... work operations. In some cases a chin strap may be necessary to keep the helmet on an employee's head..., grinding machining, masonry work, woodworking, sawing, drilling, chiseling, powered fastening, riveting...

  20. 29 CFR Appendix B to Subpart I of... - Non-mandatory Compliance Guidelines for Hazard Assessment and Personal Protective Equipment...

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR... work operations. In some cases a chin strap may be necessary to keep the helmet on an employee's head..., grinding machining, masonry work, woodworking, sawing, drilling, chiseling, powered fastening, riveting...

  1. 75 FR 32251 - Airworthiness Directives; PILATUS Aircraft Ltd. Model PC-7 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-08

    ... contains regulatory documents #0;having general applicability and legal effect, most of which are keyed #0... right lower longerons between fuselage frames 1 and 1A. The possibility of corrosion is increased... corrosion at the bonding strap connections on the left and right lower longerons between fuselage frames 1...

  2. Faculty Governance and Special-Interest Centers

    ERIC Educational Resources Information Center

    Burgan, Mary

    2009-01-01

    In the past decade or so, the practice of faculty governance has become increasingly vexed by the proliferation of special-interest research and teaching centers sponsored by outside benefactors who expect to be involved in the content and management of programs they pay for. University administrations, strapped for resources and hungry for fame,…

  3. Parents, Are You Aware of the Commercial Activity in Your School? You Should Be.

    ERIC Educational Resources Information Center

    Molnar, Alex

    2003-01-01

    Explains that financially strapped and resource-poor schools often accept corporate-sponsored educational materials and ads, especially when they come with free computers or other resources, discussing how corporations use schools to boost brand loyalty; how commercialism undermines the health of students (e.g., soda machines in schools, which…

  4. 75 FR 12150 - Airworthiness Directives; PILATUS Aircraft Ltd. Model PC-7 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-15

    ... the left and right lower longerons between fuselage frames 1 and 1A. The possibility of corrosion is... methods: Federal eRulemaking Portal: Go to http://www.regulations.gov . Follow the instructions for... at the bonding strap connections on the left and right lower longerons between fuselage frames 1 and...

  5. 78 FR 14469 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-06

    ... inspections to find cracking of the web, strap, inner chords, inner chord angle of the forward edge frame of the number 5 main entry door cutouts, the frame segment between stringers 16 and 31, and repair if... Portal: Go to http://www.regulations.gov . Follow the instructions for submitting comments. Fax: 202-493...

  6. 49 CFR 393.7 - Matter incorporated by reference.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications... Association, WSTDA-T1, 1998, incorporation by reference approved for § 393.104(e). (21) Wire Rope Users Manual...

  7. 49 CFR 393.7 - Matter incorporated by reference.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... Specification for Strapping, Flat Steel and Seals, American Society for Testing and Materials (ASTM), D3953-97, February 1998, incorporation by reference approved for § 393.104(e). (19) Welded Steel Chain Specifications... Association, WSTDA-T1, 1998, incorporation by reference approved for § 393.104(e). (21) Wire Rope Users Manual...

  8. Underwater Cycle Ergometry: Power Requirements With and Without Diver Thermal Dress

    DTIC Science & Technology

    2009-01-01

    waterproofed Collins Pedal Mate ergometers that are no longer available. A pedal shaft drives the shaft of a hysteresis brake (HB210, Magtrol; Buffalo, NY...NEDU, regular bicycle pedals with toe straps/ over canvas shoes were used in Buffalo (personal 13 communication). The foot cups used at NEDU are

  9. Underwater Cycle Ergometry: Power Requirements With and Without Diver Thermal Dress

    DTIC Science & Technology

    2009-01-01

    cycle ergometers were built at NEDU as successors to the waterproofed Collins Pedal Mate ergometers that are no longer available. A pedal shaft drives...8217 feet to the pedals. In contrast to the large foot cups and neoprene booties used at NEDU, regular bicycle pedals with toe straps2 over canvas shoes

  10. Paradoxes in science: a new view of rarity.

    Treesearch

    Sally. Duncan

    2001-01-01

    the "survey and manage" requirement of the Northwest Forest Plan is a challenge for land managers strapped for time and funds to implement it and for environmentalists concerned about its implementation. Its single species management approach raises some interesting questions.What makes these species rare to begin with? And why have they survived? On...

  11. 29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...

  12. 29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...

  13. 29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...

  14. 29 CFR 1910.155 - Scope, application and definitions applicable to this subpart.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... moisture absorption (caking) as well as to provide proper flow capabilities. Dry chemical does not include... require formal classroom instruction. (15) Enclosed structure means a structure with a roof or ceiling and... a rigid shell, energy absorption system, and chin strap intended to be worn to provide protection...

  15. 14 CFR Appendix - Special Federal Aviation Regulation No. 109

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... absorbing protective padding (foam or equivalent) such as Ensolite. (6) Shoulder Strap Loads. Where upper... must have a means to signal to the flightcrew, at the flightdeck, that the door is in the open position... that any such door is in the open configuration for takeoff and landing. (c) Each door between any...

  16. 14 CFR Appendix - Special Federal Aviation Regulation No. 109

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... absorbing protective padding (foam or equivalent) such as Ensolite. (6) Shoulder Strap Loads. Where upper... must have a means to signal to the flightcrew, at the flightdeck, that the door is in the open position... that any such door is in the open configuration for takeoff and landing. (c) Each door between any...

  17. 14 CFR Appendix - Special Federal Aviation Regulation No. 109

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... absorbing protective padding (foam or equivalent) such as Ensolite. (6) Shoulder Strap Loads. Where upper... must have a means to signal to the flightcrew, at the flightdeck, that the door is in the open position... that any such door is in the open configuration for takeoff and landing. (c) Each door between any...

  18. 14 CFR Appendix - Special Federal Aviation Regulation No. 109

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... absorbing protective padding (foam or equivalent) such as Ensolite. (6) Shoulder Strap Loads. Where upper... must have a means to signal to the flightcrew, at the flightdeck, that the door is in the open position... that any such door is in the open configuration for takeoff and landing. (c) Each door between any...

  19. 75 FR 507 - Dorel Juvenile Group; Denial of Appeal of Decision on Inconsequential Noncompliance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-01-05

    ... assembly uses two belt slides that act as a manual adjuster, the tether strap is not exposed to abrasion in... does not have the same spectral characteristics as sunlight and delivers excessive relative photon... addressed these two DJG petitions for determination of inconsequential noncompliance. In its denial of the...

  20. A Case Study: Introducing a New Benefit Plan on Campus

    ERIC Educational Resources Information Center

    Gustin, Karen; Bursic, Paul

    2004-01-01

    Many higher education institutions are strapped by benefit compensation costs for medical and pharmaceutical insurance, and there are few budget dollars left over for other health benefits, such as dental and eye care. Cornell University faced this dilemma and found voluntary dental and eye care plans to be an excellent solution. This article…

  1. Bulk densities of materials from selected pine-site hardwoods

    Treesearch

    Clyde Vidrine; George E. Woodson

    1982-01-01

    Bulk densities of hardwood materials from low and high density species were determined for green and air-dry conditions. Materials consisted of whole-tree chips, bark-free chips, bark as collected from three types of debarkers (ring, rosser head, and drum debarkers) sawdust, planer shavings, flakes, logging residues, baled branchwood, steel-strapped firewood, and...

  2. Parent, Community Groups Pressed to Fill K-12 Budget Gaps

    ERIC Educational Resources Information Center

    Fleming, Nora

    2012-01-01

    The author reports on how cash-strapped school districts turn to outside groups for help in paying for staff and academic essentials, prompting frustration from some. In states and school districts still struggling to recover from recession-induced funding cuts, parent and community groups are feeling the pressure to raise money for instructional…

  3. Technicians assist STS-47 MS Jemison prior to JSC bailout training

    NASA Technical Reports Server (NTRS)

    1992-01-01

    STS-47 Endeavour, Orbiter Vehicle (OV) 105, Mission Specialist (MS) Mae C. Jemison, assisted by technicians, adjusts a strap on her launch and entry suit (LES) prior to launch emergency egress (bailout) exercises in JSC's Mockup and Integration Laboratory Bldg 9A. Jemison is making her first flight in space.

  4. Stratospheric Ozone Reactive Chemicals Generated by Space Launches Worldwide.

    DTIC Science & Technology

    1994-11-01

    I ODCs). Their carbon - chlorine bond is severed in the stratosphere by solar photolysis or reaction. Once the carbon-chlorine bond is broken, the...include the Russian Proton and Energia , and the Chinese Long March series. Roughly half (seven per year) of the Ariane 4 launches use two solid strap-ons

  5. External Peltier Cooler For Low-Noise Amplifier

    NASA Technical Reports Server (NTRS)

    Soper, Terry A.

    1990-01-01

    Inexpensive Peltier-effect cooling module made of few commercially available parts used to reduce thermal noise in microwave amplifier. Retrofitted to almost any microwave low-noise amplifier or receiver preamplifier used in communication, telemetry, or radar. Includes copper or aluminum cold plate held tightly against unit to be cooled by strap-type worm-gear clamps.

  6. 29 CFR 1926.1437 - Floating cranes/derricks and land cranes/derricks on barges.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    .... (1) An anti two-block device is required only when hoisting personnel or hoisting over an occupied... secured. (iv) The vessel/flotation device is watertight based on the condition of the chain lockers..., strapping the crane/derrick to the vessel/flotation device with chains, or other methods of physical...

  7. 29 CFR 1926.1437 - Floating cranes/derricks and land cranes/derricks on barges.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    .... (1) An anti two-block device is required only when hoisting personnel or hoisting over an occupied... secured. (iv) The vessel/flotation device is watertight based on the condition of the chain lockers..., strapping the crane/derrick to the vessel/flotation device with chains, or other methods of physical...

  8. 29 CFR 1926.1437 - Floating cranes/derricks and land cranes/derricks on barges.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    .... (1) An anti two-block device is required only when hoisting personnel or hoisting over an occupied... secured. (iv) The vessel/flotation device is watertight based on the condition of the chain lockers..., strapping the crane/derrick to the vessel/flotation device with chains, or other methods of physical...

  9. 29 CFR 1926.1437 - Floating cranes/derricks and land cranes/derricks on barges.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    .... (1) An anti two-block device is required only when hoisting personnel or hoisting over an occupied... secured. (iv) The vessel/flotation device is watertight based on the condition of the chain lockers..., strapping the crane/derrick to the vessel/flotation device with chains, or other methods of physical...

  10. Numerical Analysis in Fracture Mechanics.

    DTIC Science & Technology

    1983-01-20

    pressuriza- tion has also been solved [66] by the HEMP code. The advantage of such supercode, however, lies in its ability to analyze elastic- plastic ...analyzing the elasto-dynamic and elastic- plastic dynamic states In fracturing 2- and 3-D prob’ems. The use of a super finite difference code to study...the finite difference elastic- plastic result of Jacobs in 1950 [2J which was followed by others In the 1960’s [3 - 5). Swedlow et al [6], on the other a

  11. Bioimpedance-Based Wearable Measurement Instrumentation for Studying the Autonomic Nerve System Response to Stressful Working Conditions

    NASA Astrophysics Data System (ADS)

    Ferreira, J.; Álvarez, L.; Buendía, R.; Ayllón, D.; Llerena, C.; Gil-Pita, R.; Seoane, F.

    2013-04-01

    The assessment of mental stress on workers under hard and stressful conditions is critical to identify which workers are not ready to undertake a mission that might put in risk their own life and the life of others. The ATREC project aims to enable Real Time Assessment of Mental Stress of the Spanish Armed Forces during military activities. Integrating sensors with garments and using wearable measurement devices, the following physiological measurements were recorded: heart and respiration rate, skin galvanic response as well as peripheral temperature. The measuring garments are the following: a sensorized glove, an upper-arm strap and a repositionable textrode chest strap system with 6 textrodes. The implemented textile-enabled instrumentation contains: one skin galvanometer, two temperature sensors, for skin and environmental, and an Impedance Cardiographer/Pneumographer containing a 1 channel ECG amplifier to record cardiogenic biopotentials. The implemented wearable systems operated accordingly to the specifications and are ready to be used for the mental stress experiments that will be executed in the coming phases of the project in healthy volunteers.

  12. Modal Test of Six-Meter Hypersonic Inflatable Aerodynamic Decelerator

    NASA Technical Reports Server (NTRS)

    Abraham, Nijo; Buehrle, Ralph; Templeton, Justin; Lindell, Mike; Hancock, Sean M.

    2014-01-01

    A modal test was performed on the six-meter Hypersonic Inflatable Aerodynamic Decelerator (HIAD) test article to gain a firm understanding of the dynamic characteristics of the unloaded structure within the low frequency range. The tests involved various configurations of the HIAD to understand the influence of the tri-torus, the varying pressure within the toroids and the influence of straps. The primary test was conducted utilizing an eletrodynamic shaker and the results were verified using a step relaxation technique. The analysis results show an increase in the structure's stiffness with respect to increasing pressure. The results also show the rise of coupled modes with the tri-torus configurations. During the testing activity, the attached straps exhibited a behavior that is similar to that described as fuzzy structures in the literature. Therefore extensive tests were also performed by utilizing foam to mitigate these effects as well as understand the modal parameters of these fuzzy sub structures. Results are being utilized to update the finite element model of the six-meter HIAD and to gain a better understanding of the modeling of complex inflatable structures.

  13. Aircraft system aft telescope cavity configuration study for Stratospheric Observatory for Infrared Astronomy (SOFIA), phase 2

    NASA Technical Reports Server (NTRS)

    1994-01-01

    The SOFIA Aircraft System (AS) Phase 1 Study was a broad-based study which addressed itself to satisfying technical and programmatic requirements by drawing from existing technology and applying cost-efficient commercial approaches to the aircraft modification. In this SOFIA AS Phase 2 Study, five critical areas of the aircraft were selected for more detailed investigation: forward pressure bulkhead, aft bulkhead, 'free' shell to bulkhead interface, shell cut-out to bulkhead interface, and flooring. The in-depth investigation of these areas upon a finite element model (FEM), with a fine grid model in areas of particular interest, is discussed. The FEM code used is called 'STRAP' and was developed by the engineering firm, Rasmussen and Associates. STRAP is NASTRAN compatible to within 1%. The loads applied to the model were approximated from known 747 envelope conditions. The areas of investigation, and a section through the fuselage is shown. The thrust of this investigation was to develop the design concepts conceived under phase 1 to the point where detailed design could be undertaken with a high level of confidence.

  14. Testing of a Miniature Loop Heat Pipe Using a Thermal Electrical Cooler for Temperature Control

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Jeong, Soeng-II; Butler, Dan

    2004-01-01

    This paper describes the design and testing of a miniature LHP having a 7 mm O.D. evaporator with an integral CC. The vapor line and liquid line are made of 1.6mm stainless steel tubing. The evaporator and the CC are connected on the outer surface by a copper strap and a thermoelectric (TEC) is installed on the strap. The TEC is used to control the CC temperature by applying an electrical current for heating or cooling. Tests performed in ambient included start-up, power cycle, sink temperature cycle, and CC temperature control using TEC. The LHP demonstrated very robust operation in all tests where the heat load varied between 0.5W and 1OOW, and the sink temperature varied between 243K and 293K. The heat leak from the evaporator to the CC was extremely small. The TEC was able to control the CC temperature within +/-0.3K under all test conditions, and the required control heater power was less than 1W.

  15. SPF/DB primary structure for supersonic aircraft (T-38 horizontal stabilizer)

    NASA Technical Reports Server (NTRS)

    Delmundo, A. R.; Mcquilkin, F. T.; Rivas, R. R.

    1981-01-01

    The structural integrity and potential cost savings of superplastic forming/diffusion bonding (SPF/DB) titanium structure for future Supersonic Cruise Research (SCR) and military aircraft primary structure applications was demonstrated. Using the horizontal stabilizer of the T-38 aircraft as a baseline, the structure was redesigned to the existing criteria and loads, using SPF/DB titanium technology. The general concept of using a full-depth sandwich structure which is attached to a steel spindle, was retained. Trade studies demonstrated that the optimum design should employ double-truss, sinewave core in the deepest section of the surface, making a transition to single-truss core in the thinner areas at the leading and trailing edges and at the tip. At the extreme thin edges of the surface, the single-truss core was changed to dot core to provide for gas passages during the SPF/DB process. The selected SPF/DB horizontal stabilizer design consisted of a one-piece SPF/DB sinewave truss core panel, a trunnion fitting, and reinforcing straps. The fitting and the straps were mechanically fastened to the SPF/DB panel.

  16. Development and Testing of an Innovative Two-Arm Focal-Plane Thermal Strap (TAFTS)

    NASA Technical Reports Server (NTRS)

    Urquiza, E.; Vasquez, C.; Rodriguez, J.; Van Gorp, B.

    2011-01-01

    Maintaining temperature stability in optical focal planes comes with the intrinsic challenge of creating a pathway that is both extremely flexible mechanically and highly conductive thermally. The task is further complicated because science-caliber optical focal planes are extremely delicate, yet their mechanical resiliency is rarely tested and documented. The mechanical engineer tasked with the thermo-mechanical design must then create a highly conductive thermal link that minimizes the tensile and shear stresses transmitted to the focal plane without design parameters on an acceptable stiffness. This paper will describe the development and testing of the thermal link developed for the Portable Remote Imaging Spectrometer (PRISM) instrument. It will provide experimentally determined mechanical stiffness plots in the three axes of interest. Analytical and experimental thermal conductance results for the two-arm focal-plane thermal strap (TAFTS), from cryogenic to room temperatures, are also presented. The paper also briefly describes some elements of the fabrication process followed in developing a novel design solution, which provides high conductance and symmetrical mechanical loading, while providing enhanced flexibility in all three degrees of freedom.

  17. New Padded Harness for Self-Acquisition of Resting 12-Lead ECGs

    NASA Technical Reports Server (NTRS)

    Schlegel, T. T.; Rood, A. T.

    2011-01-01

    We have developed a dry-electrode harness that permits easy, rapid, and unsupervised self-acquisition of resting 12-lead ECGs without the use of any disposables. Various other advantageous features of the harness include: 1) padded or inflatable cushions at the lateral sides of the torso that function to press the left arm (LA) and right arm (RA) dry electrodes mounted on cushions against sideward (as shown in the Figure below) or downward-rested arms of the subject; 2) sufficient distal placement of the arm electrodes with good abutment and without the need for adhesives, straps, bands, bracelets, or gloves on the arms; 3) padding over the sternum to avoid "tenting" in the V1 through V3 (and V3R, when present) electrode positions; 4) easy-to-don, one-piece design with an adjustable single point of connection and an adjustable shoulder strap; and 5) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar lead placements.

  18. Length and elasticity of side reins affect rein tension at trot.

    PubMed

    Clayton, Hilary M; Larson, Britt; Kaiser, LeeAnn J; Lavagnino, Michael

    2011-06-01

    This study investigated the horse's contribution to tension in the reins. The experimental hypotheses were that tension in side reins (1) increases biphasically in each trot stride, (2) changes inversely with rein length, and (3) changes with elasticity of the reins. Eight riding horses trotted in hand at consistent speed in a straight line wearing a bit and bridle and three types of side reins (inelastic, stiff elastic, compliant elastic) were evaluated in random order at long, neutral, and short lengths. Strain gauge transducers (240 Hz) measured minimal, maximal and mean rein tension, rate of loading and impulse. The effects of rein type and length were evaluated using ANOVA with Bonferroni post hoc tests. Rein tension oscillated in a regular pattern with a peak during each diagonal stance phase. Within each rein type, minimal, maximal and mean tensions were higher with shorter reins. At neutral or short lengths, minimal tension increased and maximal tension decreased with elasticity of the reins. Short, inelastic reins had the highest maximal tension and rate of loading. Since the tension variables respond differently to rein elasticity at different lengths, it is recommended that a set of variables representing different aspects of rein tension should be reported. Copyright © 2010 Elsevier Ltd. All rights reserved.

  19. Measurement of gastrocnemius muscle elasticity by shear wave elastography: association with passive ankle joint stiffness and sex differences.

    PubMed

    Chino, Kentaro; Takahashi, Hideyuki

    2016-04-01

    Passive joint stiffness is an important quantitative measure of flexibility, but is affected by muscle volume and all of the anatomical structures located within and over the joint. Shear wave elastography can assess muscle elasticity independent of the influences of muscle volume and the other nearby anatomical structures. We determined how muscle elasticity, as measured using shear wave elastography, is associated with passive joint stiffness and patient sex. Twenty-six healthy men (24.4 ± 5.9 years) and 26 healthy women (25.2 ± 4.8 years) participated in this study. The passive ankle joint stiffness and tissue elasticity of the medial gastrocnemius (MG) were quantified with the ankle in 30° plantar flexion (PF), a neutral anatomical position (NE), and 20° dorsiflexion (DF). No significant difference in passive joint stiffness by sex was observed with the ankle in PF, but significantly greater passive ankle joint stiffness in men than in women was observed in NE and DF. The MG elasticity was not significantly associated with joint stiffness in PF or NE, but it was significantly associated with joint stiffness in DF. There were no significant differences in MG elasticity by sex at any ankle position. Muscle elasticity, measured independent of the confounding effects of muscle volume and the other nearby anatomical structures, is associated with passive joint stiffness in the joint position where the muscle is sufficiently lengthened, but does not vary by sex in any joint position tested.

  20. Gender-related difference in arterial elastance during exercise in patients with hypertension.

    PubMed

    Park, Sungha; Ha, Jong-Won; Shim, Chi Young; Choi, Eui-Young; Kim, Jin-Mi; Ahn, Jeong-Ah; Lee, Se-Wha; Rim, Se-Joong; Chung, Namsik

    2008-04-01

    Exercise intolerance and heart failure with preserved ejection fraction are common in females. Recently, arterial stiffness has been suggested to be a significant contributor in the development of heart failure. How gender difference affects arterial stiffening and its response to exercise is not well known. We hypothesized that arterial elastance index during exercise would be more abnormal in females with hypertension than males. Arterial elastance index was estimated as arterial end systolic pressure/stroke volume controlled for body surface area and was measured at rest and during graded supine bicycle exercise (25 watts, 3-minute increments) in 298 patients with hypertension (149 males; 149 females; mean age, 59). The subjects were divided into 2 groups by gender. Exercise duration was significantly shorter in females compared to males (692+/-222 versus 483+/-128 seconds, P<0.001). Although arterial elastance index at baseline was significantly higher in males, the magnitude of increase was steeper in females with the magnitude of change at 75 W of exercise being significantly higher in females compared to males (0.69+/-0.83 versus 0.43+/-0.69, P=0.018). Arterial elastance index at each stage of exercise up to 75 W was independently associated with decreased exercise duration. In conclusion, despite lower arterial elastance index at rest, the increase during exercise was steeper in women with hypertension, suggesting a gender-related difference in dynamic arterial stiffness. The arterial elastance index during exercise was significantly associated with exercise duration in patients with hypertension.

  1. Peculiarities of evolutions of elastic-plastic shock compression waves in different materials

    NASA Astrophysics Data System (ADS)

    Kanel, G. I.; Savinykh, A. S.; Garkushin, G. V.; Razorenov, S. V.; Ashitkov, S. I.; Zaretsky, E. B.

    2016-11-01

    In the paper, we discuss such unexpected features in the wave evolution in solids as strongly nonlinear uniaxial elastic compression in a picosecond time range, a departure from self-similar development of the wave process which is accompanied with apparent sub-sonic wave propagation, changes of shape of elastic precursor wave as a result of variations in the material structure and the temperature, unexpected peculiarities of reflection of elastic-plastic waves from free surface.

  2. Effects of ablation depth and repair time on the corneal elastic modulus after laser in situ keratomileusis.

    PubMed

    Wang, Xiaojun; Li, Xiaona; Chen, Weiyi; He, Rui; Gao, Zhipeng; Feng, Pengfei

    2017-01-17

    The biomechanical properties of the cornea should be taken into account in the refractive procedure in order to perform refractive surgery more accurately. The effects of the ablation depth and repair time on the elastic modulus of the rabbit cornea after laser in situ keratomileusis (LASIK) are still unclear. In this study, LASIK was performed on New Zealand rabbits with different ablation depth (only typical LASIK flaps were created; residual stroma bed was 50 or 30% of the whole cornea thickness respectively). The animals without any treatment were served as normal controls. The corneal thickness was measured by ultrasonic pachymetry before animals were humanly killed after 7 or 28 days post-operatively. The corneal elastic modulus was measured by uniaxial tensile testing. A mathematical procedure considering the actual geometrics of the cornea was created to analyze the corneal elastic modulus. There were no obvious differences among all groups in the elastic modulus on after 7 days post-operatively. However, after 28th days post-operatively, there was a significant increase in the elastic modulus with 50 and 30% residual stroma bed; only the elastic modulus of the cornea with 30% residual stroma bed was significantly higher than that of 7 days. Changes in elastic modulus after LASIK suggest that this biomechanical effect may correlate with the ablation depth and repair time.

  3. Quantitative elasticity measurement of urinary bladder wall using laser-induced surface acoustic waves.

    PubMed

    Li, Chunhui; Guan, Guangying; Zhang, Fan; Song, Shaozhen; Wang, Ruikang K; Huang, Zhihong; Nabi, Ghulam

    2014-12-01

    The maintenance of urinary bladder elasticity is essential to its functions, including the storage and voiding phases of the micturition cycle. The bladder stiffness can be changed by various pathophysiological conditions. Quantitative measurement of bladder elasticity is an essential step toward understanding various urinary bladder disease processes and improving patient care. As a nondestructive, and noncontact method, laser-induced surface acoustic waves (SAWs) can accurately characterize the elastic properties of different layers of organs such as the urinary bladder. This initial investigation evaluates the feasibility of a noncontact, all-optical method of generating and measuring the elasticity of the urinary bladder. Quantitative elasticity measurements of ex vivo porcine urinary bladder were made using the laser-induced SAW technique. A pulsed laser was used to excite SAWs that propagated on the bladder wall surface. A dedicated phase-sensitive optical coherence tomography (PhS-OCT) system remotely recorded the SAWs, from which the elasticity properties of different layers of the bladder were estimated. During the experiments, series of measurements were performed under five precisely controlled bladder volumes using water to estimate changes in the elasticity in relation to various urinary bladder contents. The results, validated by optical coherence elastography, show that the laser-induced SAW technique combined with PhS-OCT can be a feasible method of quantitative estimation of biomechanical properties.

  4. Acoustic Radiation Force-Induced Creep-Recovery (ARFICR): A Noninvasive Method to Characterize Tissue Viscoelasticity.

    PubMed

    Amador Carrascal, Carolina; Chen, Shigao; Urban, Matthew W; Greenleaf, James F

    2018-01-01

    Ultrasound shear wave elastography is a promising noninvasive, low cost, and clinically viable tool for liver fibrosis staging. Current shear wave imaging technologies on clinical ultrasound scanners ignore shear wave dispersion and use a single group velocity measured over the shear wave bandwidth to estimate tissue elasticity. The center frequency and bandwidth of shear waves induced by acoustic radiation force depend on the ultrasound push beam (push duration, -number, etc.) and the viscoelasticity of the medium, and therefore are different across scanners from different vendors. As a result, scanners from different vendors may give different tissue elasticity measurements within the same patient. Various methods have been proposed to evaluate shear wave dispersion to better estimate tissue viscoelasticity. A rheological model such as the Kelvin-Voigt model is typically fitted to the shear wave dispersion to solve for the elasticity and viscosity of tissue. However, these rheological models impose strong assumptions about frequency dependence of elasticity and viscosity. Here, we propose a new method called Acoustic Radiation Force Induced Creep-Recovery (ARFICR) capable of quantifying rheological model-independent measurements of elasticity and viscosity for more robust tissue health assessment. In ARFICR, the creep-recovery time signal at the focus of the push beam is used to calculate the relative elasticity and viscosity (scaled by an unknown constant) over a wide frequency range. Shear waves generated during the ARFICR measurement are also detected and used to calculate the shear wave velocity at its center frequency, which is then used to calibrate the relative elasticity and viscosity to absolute elasticity and viscosity. In this paper, finite-element method simulations and experiments in tissue mimicking phantoms are used to validate and characterize the extent of viscoelastic quantification of ARFICR. The results suggest that ARFICR can measure tissue viscoelasticity reliably. Moreover, the results showed the strong frequency dependence of viscoelastic parameters in tissue mimicking phantoms and healthy liver.

  5. A finite difference scheme for the equilibrium equations of elastic bodies

    NASA Technical Reports Server (NTRS)

    Phillips, T. N.; Rose, M. E.

    1984-01-01

    A compact difference scheme is described for treating the first-order system of partial differential equations which describe the equilibrium equations of an elastic body. An algebraic simplification enables the solution to be obtained by standard direct or iterative techniques.

  6. Synergic effect of salivary pH baselines and low pH intakes on the force relaxation of orthodontic latex elastics

    PubMed Central

    Ajami, Shabnam; Farjood, Amin; Zare, Mahbubeh

    2017-01-01

    Background: Latex elastics are still in common use due to their low cost and high flexibility to improve sagittal discrepancies or interdigitation of teeth. Mechanical properties of elastics are influenced by several environmental factors such as pH changes. This study evaluated similar latex elastics to define the influence of synergic effect of intermittent low pH and various baselines pH of saliva. Materials and Methods: Four groups of latex elastics (3-M Unitek, 3/16 inch) were tested (n = 15 in each group). Two groups of elastics were immersed in two tanks of artificial saliva with different pH levels of 7 and 5, and two groups were immersed in two tanks of artificial saliva with intermittent drop of pH to 4. The force was measured when the elastics were stretched to 25 mm. These measurements were taken in 0, 4, 8, 12, 24, 36, and 48 h for each group. Repeated measures analysis of variance (RMANOVA) and post-hoc Tukey's test were used to assess the findings. The level of significance was 0.05%. Results: The interaction between pH and time analyzed with RMANOVA showed no significant differences (P > 0.05) except in 36 h (P = 0.014). The Tukey's analysis showed that each comparison between any two groups did not indicate significant differences (P > 0.05) except between Groups 1 and 3 and between Groups 2 and 3 (P < 0.05). Conclusion: No significant correlation was seen between fluctuation of pH and force degradation in latex elastic band except in 36 h. PMID:28348621

  7. Elastic moduli of a smectic membrane: a rod-level scaling analysis

    NASA Astrophysics Data System (ADS)

    Wensink, H. H.; Morales Anda, L.

    2018-02-01

    Chiral rodlike colloids exposed to strong depletion attraction may self-assemble into chiral membranes whose twisted director field differs from that of a 3D bulk chiral nematic. We formulate a simple microscopic variational theory to determine the elastic moduli of rods assembled into a bidimensional smectic membrane. The approach is based on a simple Onsager-Straley theory for a non-uniform director field that we apply to describe rod twist within the membrane. A microscopic approach enables a detailed estimate of the individual Frank elastic moduli (splay, twist and bend) as well as the twist penetration depth of the smectic membrane in relation to the rod density and shape. We find that the elastic moduli are distinctly different from those of a bulk nematic fluid, with the splay elasticity being much stronger and the curvature elasticity much weaker than for rods assembled in a three-dimensional nematic fluid. We argue that the use of the simplistic one-constant approximation in which all moduli are assumed to be of equal magnitude is not appropriate for modelling the structure-property relation of smectic membranes.

  8. Elastic Properties of Chimpanzee Craniofacial Cortical Bone

    PubMed Central

    Gharpure, Poorva; Kontogiorgos, Elias D.; Opperman, Lynne A.; Ross, Callum F.; Strait, David S.; Smith, Amanda; Pryor, Leslie C.; Wang, Qian; Dechow, Paul C.

    2017-01-01

    Relatively few assessments of cranial biomechanics formally take into account variation in the material properties of cranial cortical bone. Our aim was to characterize the elastic properties of chimpanzee craniofacial cortical bone and compare these to the elastic properties of dentate human craniofacial cortical bone. From seven cranial regions, 27 cylindrical samples were harvested from each of five chimpanzee crania. Assuming orthotropy, axes of maximum stiffness in the plane of the cortical plate were derived using modified equations of Hooke’s law in a Mathcad program. Consistent orientations among individuals were observed in the zygomatic arch and alveolus. The density of cortical bone showed significant regional variation (P<0.001). The elastic moduli demonstrated significant differences between sites, and a distinct pattern where E3 >E2 > E1. Shear moduli were significantly different among regions (P<0.001). The pattern by which chimpanzee cranial cortical bone varies in elastic properties resembled that seen in humans, perhaps suggesting that the elastic properties of craniofacial bone in fossil hominins can be estimated with at least some degree of confidence. PMID:27870344

  9. Elastic-Mathematical Theory of Cells and Mitochondria in Swelling Process

    PubMed Central

    Mela, M. J.

    1968-01-01

    The elastic behavior of the cell wall as a function of the temperature has been studied with particular attention being given to the swelling of egg cells of Strongylocentrotus purpuratus and Crassostrea virginica in different sea water concentrations at different temperatures. It was found that the modulus of elasticity is a nonlinear function of temperature. At about 12-13°C the modulus of elasticity (E) is constant, independent of the stress (σ) and strain (εν) which exist at the cell wall; the membranous material follows Hooke's law, and E ≈ 3 × 107 dyn/cm2 for S. purpuratus and C. virginica. When the temperature is higher or lower than 12-13°C, the modulus of elasticity increases, and the membranous material does not follow Hooke's law, but is almost directly proportional to the stresses existing at the cell wall. On increasing the stress, the function Eσ = E(σ) approaches saturation. The corresponding stress-strain diagrams, σ = σ(εν), and the graphs, Eσ = E(σ) and Eσ = E(t) are given. The cyto-elastic phenomena at the membrane are discussed. PMID:5689191

  10. Elastic and viscoelastic effects in rubber/air acoustic band gap structures: A theoretical and experimental study

    NASA Astrophysics Data System (ADS)

    Merheb, B.; Deymier, P. A.; Jain, M.; Aloshyna-Lesuffleur, M.; Mohanty, S.; Berker, A.; Greger, R. W.

    2008-09-01

    The transmission of acoustic waves through centimeter-scale elastic and viscoelastic two-dimensional silicone rubber/air phononic crystal structures is investigated theoretically and experimentally. We introduce a finite difference time domain method for two-dimensional elastic and viscoelastic composite structures. Elastic fluid-solid phononic crystals composed of a two-dimensional array of cylindrical air inclusions in a solid rubber matrix, as well as an array of rubber cylinders in an air matrix, are shown to behave similarly to fluid-fluid composite structures. These systems exhibit very wide band gaps in their transmission spectra that extend to frequencies in the audible range of the spectrum. This effect is associated with the very low value of the transverse speed of sound in rubber compared to that of the longitudinal polarization. The difference in transmission between elastic and viscoelastic rubber/air crystals results from attenuation of transmission over a very wide frequency range, leaving only narrow passing bands at very low frequencies. These phononic crystals demonstrate the practical design of elastic or viscoelastic solid rubber/air acoustic band gap sound barriers with small dimensions.

  11. NDE evidence for the damage arrestment performance of PRSEUS composite cube during high-pressure load test

    NASA Astrophysics Data System (ADS)

    Johnston, Patrick H.; Parker, F. Raymond

    2014-02-01

    As an approach to light-weight, cost-effective and manufacturable structures required to enable the hybrid wing body aircraft, The Boeing Company, Inc. and NASA have developed the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. A PRSEUS pressure cube was developed as a risk reduction test article to examine a new integral cap joint concept as part of a building block approach for technology development of the PRSEUS concept. The overall specimen strength exceeded the 18.4 psi load requirement as testing resulted in the cube reaching a final pressure load of around 48 psi prior to catastrophic failure. The cube pressure test verified that the joints and structure were capable of sustaining the required loads, and represented the first testing of joined PRSEUS structure. This paper will address the damage arrestment performance of the stitched PRSEUS structure. Following catastrophic failure of the cube, ultrasonic pulse-echo inspection found that the localized damage, surrounding a barely-visible impact damage site, did not change noticeably between just after impact and catastrophic failure of the cube, and did not play a role in the catastrophic failure event. Ultrasonic inspection of the remaining intact cube panels presented three basic types of indications: delaminations between laminae parallel to the face sheets, lying between face sheet and tear strap layers, or between tear strap and flange layers; delaminations above the noodles of stringers, frames or integral caps, lying within face sheet or tear strap layers; and delaminations between the laminae in the inner fillets of the integral caps, where pulloff stresses were expected to be highest. Delaminations of all three types were predominantly contained by the first row of stitches encountered. For the small fraction of delaminations extending beyond the first row of stitches, all were contained by the second stitch row.

  12. NDE Evidence for the Damage Arrestment Performance of PRSEUS Composite Cube During High-Pressure Load Test

    NASA Technical Reports Server (NTRS)

    Johnston, Patrick H.; Parker, F. Raymond

    2013-01-01

    As an approach to light-weight, cost-effective and manufacturable structures required to enable the hybrid wing body aircraft, The Boeing Company, Inc. and NASA have developed the Pultruded Rod Stitched Efficient Unitized Structure (PRSEUS) concept. A PRSEUS pressure cube was developed as a risk reduction test article to examine a new integral cap joint concept as part of a building block approach for technology development of the PRSEUS concept. The overall specimen strength exceeded the 18.4 psi load requirement as testing resulted in the cube reaching a final pressure load of around 48 psi prior to catastrophic failure. The cube pressure test verified that the joints and structure were capable of sustaining the required loads, and represented the first testing of joined PRSEUS structure. This paper will address the damage arrestment performance of the stitched PRSEUS structure. Following catastrophic failure of the cube, ultrasonic pulse-echo inspection found that the localized damage, surrounding a barely-visible impact damage site, did not change noticeably between just after impact and catastrophic failure of the cube, and did not play a role in the catastrophic failure event. Ultrasonic inspection of the remaining intact cube panels presented three basic types of indications: delaminations between laminae parallel to the face sheets, lying between face sheet and tear strap layers, or between tear strap and flange layers; delaminations above the noodles of stringers, frames or integral caps, lying within face sheet or tear strap layers; and delaminations between the laminae in the inner fillets of the integral caps, where pulloff stresses were expected to be highest. Delaminations of all three types were predominantly contained by the first row of stitches encountered. For the small fraction of delaminations extending beyond the first row of stitches, all were contained by the second stitch row.

  13. Geometric charges in theories of elasticity and plasticity

    NASA Astrophysics Data System (ADS)

    Moshe, Michael

    The mechanics of many natural systems is governed by localized sources of stresses. Examples include ''plastic events'' that occur in amorphous solids under external stress, defects formation in crystalline material, and force-dipoles applied by cells adhered to an elastic substrate. Recent developments in a geometric formulation of elasticity theory paved the way for a unifying mathematical description of such singular sources of stress, as ''elastic charges''. In this talk I will review basic results in this emerging field, focusing on the geometry and mechanics of elastic charges in two-dimensional solid bodies. I will demonstrate the applicability of this new approach in three different problems: failure of an amorphous solid under load, mechanics of Kirigami, and wrinkle patterns in geometrically-incompatible elastic sheets.

  14. Muscle activity during knee-extension strengthening exercise performed with elastic tubing and isotonic resistance.

    PubMed

    Jakobsen, Markus Due; Sundstrup, Emil; Andersen, Christoffer H; Bandholm, Thomas; Thorborg, Kristian; Zebis, Mette K; Andersen, Lars L

    2012-12-01

    While elastic resistance training, targeting the upper body is effective for strength training, the effect of elastic resistance training on lower body muscle activity remains questionable. The purpose of this study was to evaluate the EMG-angle relationship of the quadriceps muscle during 10-RM knee-extensions performed with elastic tubing and an isotonic strength training machine. 7 women and 9 men aged 28-67 years (mean age 44 and 41 years, respectively) participated. Electromyographic (EMG) activity was recorded in 10 muscles during the concentric and eccentric contraction phase of a knee extension exercise performed with elastic tubing and in training machine and normalized to maximal voluntary isometric contraction (MVC) EMG (nEMG). Knee joint angle was measured during the exercises using electronic inclinometers (range of motion 0-90°). When comparing the machine and elastic resistance exercises there were no significant differences in peak EMG of the rectus femoris (RF), vastus lateralis (VL), vastus medialis (VM) during the concentric contraction phase. However, during the eccentric phase, peak EMG was significantly higher (p<0.01) in RF and VM when performing knee extensions using the training machine. In VL and VM the EMG-angle pattern was different between the two training modalities (significant angle by exercise interaction). When using elastic resistance, the EMG-angle pattern peaked towards full knee extension (0°), whereas angle at peak EMG occurred closer to knee flexion position (90°) during the machine exercise. Perceived loading (Borg CR10) was similar during knee extensions performed with elastic tubing (5.7±0.6) compared with knee extensions performed in training machine (5.9±0.5). Knee extensions performed with elastic tubing induces similar high (>70% nEMG) quadriceps muscle activity during the concentric contraction phase, but slightly lower during the eccentric contraction phase, as knee extensions performed using an isotonic training machine. During the concentric contraction phase the two different conditions displayed reciprocal EMG-angle patterns during the range of motion. 5.

  15. Halo vest instrumentation

    NASA Astrophysics Data System (ADS)

    Huston, Dryver R.; Krag, Martin

    1996-05-01

    The halo vest is a head and neck immobilization system that is often used on patients that are recovering from cervical trauma or surgery. The halo vest system consists of a rigid halo that is firmly attached to the skull, an upright support structure for stabilization and immobilization, and a torso-enveloping vest. The main purpose of this study was to measure the forces that are carried by the halo-vest structure as the subject undergoes various activities of daily living and external loading for different vest designs. A tethered strain gage load cell based instrumentation system was used to take these load measurements on ten different subjects. Three different halo-vest systems were evaluated. The primary difference between the vests was the amount of torso coverage and the use of shoulder straps. The loads were measured, analyzed and used to compare the vests and to create a model of halo-vest-neck mechanics. Future applications of this technology to standalone data logging, pin-load measuring and biofeedback applications are discussed.

  16. Correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise.

    PubMed

    Yoon, Jung-Gyu

    2018-01-01

    [Purpose] The purpose of this study was to examine correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise. [Subjects and Methods] The subjects of this study were 24 healthy men. C90 area, C90 angle, trace length, sway average velocity for body sway index were measured using a force plate by BT4. The collected data were analyzed using Kendall's coefficient of concordance. [Results] All of body sway index on measuring follow up 24 hours after removing tape were significantly decreased than before and right after plyometric exercise. No significant correlations were found between body sway index and different expansibility of the elastic tape. [Conclusion] It appears that different expansibility of the elastic tape does not affect the ability to body sway index. Carry over effect of taping was verified on measuring follow up 24 hours after removing tape through the decreasing body sway index.

  17. C-Phycocyanin Hydration Water Dynamics in the Presence of Trehalose: An Incoherent Elastic Neutron Scattering Study at Different Energy Resolutions

    PubMed Central

    Gabel, Frank; Bellissent-Funel, Marie-Claire

    2007-01-01

    We present a study of C-phycocyanin hydration water dynamics in the presence of trehalose by incoherent elastic neutron scattering. By combining data from two backscattering spectrometers with a 10-fold difference in energy resolution we extract a scattering law S(Q,ω) from the Q-dependence of the elastic intensities without sampling the quasielastic range. The hydration water is described by two dynamically different populations—one diffusing inside a sphere and the other diffusing quasifreely—with a population ratio that depends on temperature. The scattering law derived describes the experimental data from both instruments excellently over a large temperature range (235–320 K). The effective diffusion coefficient extracted is reduced by a factor of 10–15 with respect to bulk water at corresponding temperatures. Our approach demonstrates the benefits and the efficiency of using different energy resolutions in incoherent elastic neutron scattering over a large angular range for the study of biological macromolecules and hydration water. PMID:17350998

  18. Finite element investigation of temperature dependence of elastic properties of carbon nanotube reinforced polypropylene

    NASA Astrophysics Data System (ADS)

    Ahmadi, Masoud; Ansari, Reza; Rouhi, Saeed

    2017-11-01

    This paper aims to investigate the elastic modulus of the polypropylene matrix reinforced by carbon nanotubes at different temperatures. To this end, the finite element approach is employed. The nanotubes with different volume fractions and aspect ratios (the ratio of length to diameter) are embedded in the polymer matrix. Besides, random and regular algorithms are utilized to disperse carbon nanotubes in the matrix. It is seen that as the pure polypropylene, the elastic modulus of carbon nanotube reinforced polypropylene decreases by increasing the temperature. It is also observed that when the carbon nanotubes are dispersed parallelly and the load is applied along the nanotube directions, the largest improvement in the elastic modulus of the nanotube/polypropylene nanocomposites is obtained.

  19. Atomic force microscopy studies on cellular elastic and viscoelastic properties.

    PubMed

    Li, Mi; Liu, Lianqing; Xi, Ning; Wang, Yuechao

    2018-01-01

    In this work, a method based on atomic force microscopy (AFM) approach-reside-retract experiments was established to simultaneously quantify the elastic and viscoelastic properties of single cells. First, the elastic and viscoelastic properties of normal breast cells and cancerous breast cells were measured, showing significant differences in Young's modulus and relaxation times between normal and cancerous breast cells. Remarkable differences in cellular topography between normal and cancerous breast cells were also revealed by AFM imaging. Next, the elastic and viscoelasitc properties of three other types of cell lines and primary normal B lymphocytes were measured; results demonstrated the potential of cellular viscoelastic properties in complementing cellular Young's modulus for discerning different states of cells. This research provides a novel way to quantify the mechanical properties of cells by AFM, which allows investigation of the biomechanical behaviors of single cells from multiple aspects.

  20. First-principles investigations on structural, elastic, electronic properties and Debye temperature of orthorhombic Ni3Ta under pressure

    NASA Astrophysics Data System (ADS)

    Li, Pan; Zhang, Jianxin; Ma, Shiyu; Jin, Huixin; Zhang, Youjian; Zhang, Wenyang

    2018-06-01

    The structural, elastic, electronic properties and Debye temperature of Ni3Ta under different pressures are investigated using the first-principles method based on density functional theory. Our calculated equilibrium lattice parameters at 0 GPa well agree with the experimental and previous theoretical results. The calculated negative formation enthalpies and elastic constants both indicate that Ni3Ta is stable under different pressures. The bulk modulus B, shear modulus G, Young's modulus E and Poisson's ratio ν are calculated by the Voigt-Reuss-Hill method. The bigger ratio of B/G indicates Ni3Ta is ductile and the pressure can improve the ductility of Ni3Ta. In addition, the results of density of states and the charge density difference show that the stability of Ni3Ta is improved by the increasing pressure. The Debye temperature ΘD calculated from elastic modulus increases along with the pressure.

  1. Bulk microstructure and local elastic properties of carbon nanocomposites studied by impulse acoustic microscopy technique

    NASA Astrophysics Data System (ADS)

    Levin, V.; Petronyuk, Yu.; Morokov, E.; Chernozatonskii, L.; Kuzhir, P.; Fierro, V.; Celzard, A.; Bellucci, S.; Bistarelli, S.; Mastrucci, M.; Tabacchioni, I.

    2016-05-01

    Bulk microstructure and elastic properties of epoxy-nanocarbon nanocomposites for diverse types and different content of carbon nanofiller has been studied by using impulse acoustic microscopy technique. It has been shown occurrence of various types of mesoscopic structure formed by nanoparticles inside the bulk of nanocomposite materials, including nanoparticle conglomerates and nanoparticle aerogel systems. In spite of the bulk microstructure, nanocarbon composites demonstrate elastic uniformity and negligible influence of nanofiller on elastic properties of carbon nanocomposite materials.

  2. A comparison between different finite elements for elastic and aero-elastic analyses.

    PubMed

    Mahran, Mohamed; ELsabbagh, Adel; Negm, Hani

    2017-11-01

    In the present paper, a comparison between five different shell finite elements, including the Linear Triangular Element, Linear Quadrilateral Element, Linear Quadrilateral Element based on deformation modes, 8-node Quadrilateral Element, and 9-Node Quadrilateral Element was presented. The shape functions and the element equations related to each element were presented through a detailed mathematical formulation. Additionally, the Jacobian matrix for the second order derivatives was simplified and used to derive each element's strain-displacement matrix in bending. The elements were compared using carefully selected elastic and aero-elastic bench mark problems, regarding the number of elements needed to reach convergence, the resulting accuracy, and the needed computation time. The best suitable element for elastic free vibration analysis was found to be the Linear Quadrilateral Element with deformation-based shape functions, whereas the most suitable element for stress analysis was the 8-Node Quadrilateral Element, and the most suitable element for aero-elastic analysis was the 9-Node Quadrilateral Element. Although the linear triangular element was the last choice for modal and stress analyses, it establishes more accurate results in aero-elastic analyses, however, with much longer computation time. Additionally, the nine-node quadrilateral element was found to be the best choice for laminated composite plates analysis.

  3. Elastic-mathematical theory of cells and mitochondria in swelling process. II. Effect of temperature upon modulus of elasticity of membranous material of egg cells of sea urchin, Strongylocentrotus purpuratus, and of oyster, Crassostrea virginica.

    PubMed

    Mela, M J

    1968-01-01

    The elastic behavior of the cell wall as a function of the temperature has been studied with particular attention being given to the swelling of egg cells of Strongylocentrotus purpuratus and Crassostrea virginica in different sea water concentrations at different temperatures. It was found that the modulus of elasticity is a nonlinear function of temperature. At about 12-13 degrees C the modulus of elasticity (E) is constant, independent of the stress (sigma) and strain (epsilon(nu)) which exist at the cell wall; the membranous material follows Hooke's law, and E approximately 3 x 10(7) dyn/cm(2) for S. purpuratus and C. virginica. When the temperature is higher or lower than 12-13 degrees C, the modulus of elasticity increases, and the membranous material does not follow Hooke's law, but is almost directly proportional to the stresses existing at the cell wall. On increasing the stress, the function E(sigma) = E(sigma) approaches saturation. The corresponding stress-strain diagrams, sigma = sigma(epsilon(nu)), and the graphs, E(sigma) = E(sigma) and E(sigma) = E(t) are given. The cyto-elastic phenomena at the membrane are discussed.

  4. Metal nanoplates: Smaller is weaker due to failure by elastic instability

    NASA Astrophysics Data System (ADS)

    Ho, Duc Tam; Kwon, Soon-Yong; Park, Harold S.; Kim, Sung Youb

    2017-11-01

    Under mechanical loading, crystalline solids deform elastically, and subsequently yield and fail via plastic deformation. Thus crystalline materials experience two mechanical regimes: elasticity and plasticity. Here, we provide numerical and theoretical evidence to show that metal nanoplates exhibit an intermediate mechanical regime that occurs between elasticity and plasticity, which we call the elastic instability regime. The elastic instability regime begins with a decrease in stress, during which the nanoplates fail via global, and not local, deformation mechanisms that are distinctly different from traditional dislocation-mediated plasticity. Because the nanoplates fail via elastic instability, the governing strength criterion is the ideal strength, rather than the yield strength, and as a result, we observe a unique "smaller is weaker" trend. We develop a simple surface-stress-based analytic model to predict the ideal strength of the metal nanoplates, which accurately reproduces the smaller is weaker behavior observed in the atomistic simulations.

  5. Elastic-plastic finite-element analyses of thermally cycled double-edge wedge specimens

    NASA Technical Reports Server (NTRS)

    Kaufman, A.; Hunt, L. E.

    1982-01-01

    Elastic-plastic stress-strain analyses were performed for double-edge wedge specimens subjected to thermal cycling in fluidized beds at 316 and 1088 C. Four cases involving different nickel-base alloys (IN 100, Mar M-200, NASA TAZ-8A, and Rene 80) were analyzed by using the MARC nonlinear, finite element computer program. Elastic solutions from MARC showed good agreement with previously reported solutions obtained by using the NASTRAN and ISO3DQ computer programs. Equivalent total strain ranges at the critical locations calculated by elastic analyses agreed within 3 percent with those calculated from elastic-plastic analyses. The elastic analyses always resulted in compressive mean stresses at the critical locations. However, elastic-plastic analyses showed tensile mean stresses for two of the four alloys and an increase in the compressive mean stress for the highest plastic strain case.

  6. Flow units perspective on elastic recovery under sharp contact loading in metallic glasses

    NASA Astrophysics Data System (ADS)

    Shahzad, K.; Gulzar, A.; Wang, W. H.

    2016-12-01

    The obscure nature of glass physics has led to develop various correlations between different parameters and properties of metallic glasses. Despite these correlations, the clear picture of plastic deformation is still lacking. We have measured elastic recovery in metallic glasses by indentation, and found the elastic recovery correlate with different properties and parameters of metallic glasses. All these observations can be quite well explained with flow unit model which could provide clearer picture on the plastic deformations and nature of the metallic glasses.

  7. Force degradation of orthodontic latex elastics: An in-vivo study.

    PubMed

    Qodcieh, Sadeq M Adel; Al-Khateeb, Susan N; Jaradat, Ziad W; Abu Alhaija, Elham S J

    2017-03-01

    Our objectives were to assess the force degradation of orthodontic latex elastics over 48 hours in vivo and to study the relationship between the amount of mouth opening and the degree of force decay. Fifty-two orthodontic patients wearing fixed appliances using Class II elastics were asked to wear premeasured-force 3/16-in heavy and medium intermaxillary elastics. The force amounts were measured and compared at different time intervals. Fifty percent of the force was lost after 3.9 hours for the medium elastics and after 4.9 hours for the heavy elastics. A continuous significant force drop in all elastics was seen at all time intervals (P <0.05, P <0.001). There was greater force loss in the heavy elastics compared with the medium elastics in vivo at all time intervals (P <0.001); the rates of force loss, however, were similar. Fifty percent of force degradation occurred in the first 4 to 5 hours. Because of breakage and for oral hygiene purposes, orthodontic elastics should be changed daily; otherwise, elastics can be used for 48 hours. Force decay of the elastics was correlated to the lateral distance between the maxillary canine and the mandibular first molar in occlusion. Copyright © 2016 American Association of Orthodontists. Published by Elsevier Inc. All rights reserved.

  8. Hybrid Vehicles

    DTIC Science & Technology

    2008-12-08

    chassis) by a ground strap, wire, welded connection or other suitable low-resistance mechanical connection. Case ground connectors routed from other...environment of a hybrid electric vehicle. Alternative temperature measuring transducers, e.g., thermistors , should be considered when thermocouples are...A 3. Is the ground connection to the chassis or frame mechanically secured by one of the following methods? a. Secured to a spot- welded

  9. AGARD (Advisory Group for Aerospace Research & Development) Index of Publications, 1980-1982.

    DTIC Science & Technology

    1984-01-01

    anthropometric dummy. The shoulder rotation mechanism with good crashworthy features which car be strap of the seat belt was pulled various distances up to...nr orgo ". g~aion Systems criteria for noodling goalies of Roof-time sIMUlation An) roitspensabre trot oon’us,.r * lr-, r’ihr.--r~ ;r rpriscr

  10. A Higher Education--A Polemic (For a Change)

    ERIC Educational Resources Information Center

    Peters, Lloyd

    2015-01-01

    The BBC Radio 4 comedy-drama "A Higher Education" was written in 1999 to present a satire of a dysfunctional and cash-strapped university (Northfield) led by the egotistical and amoral Head of Drama, Don Crookfield (played by Rik Mayall). For those of us passionately engaged in the provision of higher education today, the satire also…

  11. Biomechanical Assessment of Rucksack Shoulder Strap Attachment Location: Effect on Load Distribution to the Torso

    DTIC Science & Technology

    2001-05-01

    varied vertical heights and horizontal positions. Optotrak position markers indicated by white diamonds). The position and mass of the payload (25 kg...shoulders and 45 N (+/- 2) at the waist and recorded for all configurations. An Optotrak 3-D motion tracking system, accuracy +/- 0.1 mm, was used to

  12. Steam-bending properties of southern pine

    Treesearch

    Truett J. Lemoine; Peter Koch

    1971-01-01

    Southern pine wood can be successfully steam-bent if the bending jig incorporates a flexible metal bending strap together with a mechanism to apply a uniform end compression load during the bending operation. With clear, 1/2- and 1-inch-thick southern pine at 17-percent moisture content, highest bending rating where obtained with fast-grown, vertical-grain, low-density...

  13. 78 FR 60804 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-02

    ... detailed and eddy current inspections to detect cracking of the frame web around the cutout for the doorstop intercostal strap at the aft side of the station (STA) 291.5 frame at stringer 16R, and corrective... various locations of the STA 277 to STA 291.5 frames and intercostals, including webs, chords, clips, and...

  14. 16 CFR 1203.15 - Positional stability test (roll-off resistance).

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... any slack. (3) Suspend the dynamic impact system from the helmet by positioning the flexible strap... positions. (3) Dynamic impact apparatus. A dynamic impact apparatus shall be used to apply a shock load to a helmet secured to the test headform. The dynamic impact apparatus shall allow a 4-kg (8.8-lb) drop weight...

  15. 29 CFR 1926.959 - Lineman's body belts, safety straps, and lanyards.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... tool pockets. On shifting D belts, this measurement for pocket tabs shall be taken when the D ring section is centered. (3) A maximum of four (4) tool loops shall be so situated on the body belt that four... of tool loops, and any other attachments. (4) Suitable copper, steel, or equivalent liners shall be...

  16. 46 CFR 160.049-4 - Construction and workmanship.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... or less in each layer, cemented together with an all-purpose vinyl adhesive such as or equivalent to U.S. Rubber No. M-6256 or Minnesota Mining No. EC-870 and No. EC-1070; (ii) Three layers or less that may be cemented; and (iii) Staggered butts and seams of adjacent layers. (d) Grab Straps. Grab...

  17. Early Rockets

    NASA Image and Video Library

    2004-04-15

    Less interested in the scientific fundamentals of rocketry, many writers of popular literature and science fiction discovered one of the most vital elements in the formula for space travel, a fertile imagination. Under the impression that the sun "draws up" dewdrops, Cyrano de Bergerac suggested fancifully that one might fly by trapping dew in bottles, strapping the bottles to oneself, and standing in sunlight.

  18. 49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 2 2013-10-01 2013-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...

  19. 49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 2 2014-10-01 2014-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...

  20. 49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...

  1. 49 CFR 176.74 - On deck stowage of break-bulk hazardous materials.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 2 2012-10-01 2012-10-01 false On deck stowage of break-bulk hazardous materials... CARRIAGE BY VESSEL General Handling and Stowage § 176.74 On deck stowage of break-bulk hazardous materials... and proper lashing by use of wire rope, strapping or other means, including shoring and bracing, or...

  2. Cristoforetti in Crew quarters

    NASA Image and Video Library

    2014-12-06

    iss042e023422 (12/6/14) --- Expedition 42 Flight Engineer Samantha Cristoforetti of the European Space Agency (ESA) on 6 December 2014 is seen inside of a sleeping bag in her personal crew quarters on the International Space Station. Astronauts will strap the bag to the wall to prevent from free floating and potentially bumping into equipment while sleeping.

  3. Kadenyuk sleeps strapped to the middeck wall

    NASA Image and Video Library

    1997-11-28

    STS087-323-030 (19 November – 5 December 1997) --- Ukrainian payload specialist Leonid K. Kadenyuk blocks out the world and much more as he sleeps on the mid-deck of the Earth-orbiting Space Shuttle Columbia. Kadenyuk joined five NASA astronauts for 16 days aboard Columbia in support of the United States Microgravity Payload (USMP) mission.

  4. Cost Issues Unresolved in Chicago

    ERIC Educational Resources Information Center

    Sawchuk, Stephen

    2012-01-01

    Chicago teachers voted last week to suspend a 7-day-old strike, sending some 350,000 students back to the classroom and paving the way for the teaching force to vote on a tentative contract. But for many in the Windy City, the contract has raised another potentially tall hurdle: how the cash-strapped district will manage to pay for it. District…

  5. OER and the Common Core

    ERIC Educational Resources Information Center

    Waters, John K.

    2013-01-01

    If anyone had thought to recognize a K-12 educational buzzword of the year for 2012, it would surely have been "open educational resources" (OER). Ed tech media has fairly hummed with the topic, largely with exciting predictions: OER would give cash-strapped K-12 educators access to high-quality tools and content for their classrooms at little or…

  6. Opportunity through Education: Two Proposals. Policy Brief Number 181

    ERIC Educational Resources Information Center

    Whitehurst, Grover J.

    2011-01-01

    The new normal for local, state and federal governments is fiscal austerity. Although President Obama supported education during his State of the Union address and in his budget proposal to Congress, cash-strapped localities and states--which foot most of the bill for educating America's children--may have to balance their budgets with cuts to…

  7. State Colleges Seeking More Out-of-State, International Students amid Fiscal Crunch

    ERIC Educational Resources Information Center

    Hu, Helen

    2011-01-01

    Faced with budget cuts, some cash-strapped state universities are stepping up their recruitment of higher paying out-of-state undergraduates, a move that critics say is unfair to the states' residents and could affect in-state minority applicants. The University of California system and the University of Washington in Seattle have openly declared…

  8. Astronaut Story Musgrave during final stages of exercise in the WETF

    NASA Technical Reports Server (NTRS)

    1982-01-01

    Astronaut Story Musgrave, STS-6 mission specialist, checks a sequence list on his spacesuit during the final stages of suit-donning exercise in the weightless environment test facility (WETF). He is wearing the full extravehicular mobility unit (EMU), including helmet and gloves and is strapped in to the platform for movement into the water.

  9. Strapping Wings on a Caterpillar and Calling It a Butterfly: When Systemic Change Is Not Systemic

    ERIC Educational Resources Information Center

    Duffy, Francis M.

    2008-01-01

    This article challenges misperceptions about the definition of systemic change in school districts. While many contemporary change efforts are described as "systemic," in fact, they are not. The author also argues that a special instance of systemic change known as systemic transformational change is required to transform entire school…

  10. Taxing health benefits: snake oil ... or smart health policy?

    PubMed

    Kirkland, L; Havighurst, C C

    1993-01-01

    Limiting the tax-free treatment of employer-paid health benefits is a cornerstone of managed competition, the health reform approach favored by the Clinton Administration. Organized labor argues that the idea is a double-whammy for wage-strapped workers, while a leading academic calls it a good solution to one of the nation's worst public policies.

  11. Teacher Layoffs: Rethinking "Last-Hired, First-Fired" Policies

    ERIC Educational Resources Information Center

    National Council on Teacher Quality, 2010

    2010-01-01

    In the past year, cash-strapped districts have been handing out pink slips by the hundreds, and some, by the thousands. The Bureau of Labor Statistics estimates that nearly 60,000 teachers were laid off in 2009. State budget gaps and deficit projections, with federal stimulus funding already spent, suggest more of the same for 2010. Some observers…

  12. Cyrano de Bergerac

    NASA Technical Reports Server (NTRS)

    2004-01-01

    Less interested in the scientific fundamentals of rocketry, many writers of popular literature and science fiction discovered one of the most vital elements in the formula for space travel, a fertile imagination. Under the impression that the sun 'draws up' dewdrops, Cyrano de Bergerac suggested fancifully that one might fly by trapping dew in bottles, strapping the bottles to oneself, and standing in sunlight.

  13. 49 CFR 571.225 - Standard No. 225; Child restraint anchorage systems.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., lock the seat belt retractor, and tighten the tether belt strap to remove all slack. A rearward force... remove any slack or tension. (c) Apply the force— (1) Initially, in a forward direction in a vertical... rearward extensions of the SFAD is adjusted to remove any slack or tension. Apply a preload force of 500 N...

  14. Cell Elasticity Determines Macrophage Function

    PubMed Central

    Patel, Naimish R.; Bole, Medhavi; Chen, Cheng; Hardin, Charles C.; Kho, Alvin T.; Mih, Justin; Deng, Linhong; Butler, James; Tschumperlin, Daniel; Fredberg, Jeffrey J.; Krishnan, Ramaswamy; Koziel, Henry

    2012-01-01

    Macrophages serve to maintain organ homeostasis in response to challenges from injury, inflammation, malignancy, particulate exposure, or infection. Until now, receptor ligation has been understood as being the central mechanism that regulates macrophage function. Using macrophages of different origins and species, we report that macrophage elasticity is a major determinant of innate macrophage function. Macrophage elasticity is modulated not only by classical biologic activators such as LPS and IFN-γ, but to an equal extent by substrate rigidity and substrate stretch. Macrophage elasticity is dependent upon actin polymerization and small rhoGTPase activation, but functional effects of elasticity are not predicted by examination of gene expression profiles alone. Taken together, these data demonstrate an unanticipated role for cell elasticity as a common pathway by which mechanical and biologic factors determine macrophage function. PMID:23028423

  15. Detachment of affinity-captured bioparticles by elastic deformation of a macroporous hydrogel

    PubMed Central

    Dainiak, Maria B.; Kumar, Ashok; Galaev, Igor Yu.; Mattiasson, Bo

    2006-01-01

    Adsorption of bioparticles to affinity surfaces involves polyvalent interactions, complicating greatly the recovery of the adsorbed material. A unique system for the efficient binding and release of different cells and particles is described. Affinity-bound bioparticles and synthetic particles are detached from the macroporous hydrogel matrix, a so-called cryogel, when the cryogel undergoes elastic deformation. The particle detachment upon elastic deformation is believed to be due to breaking of many of the multipoint attachments between the particles and the affinity matrix and the change in the distance between affinity ligands when the matrix is deformed. However, no release of affinity-bound protein occurred upon elastic deformation. The phenomenon of particle detachment upon elastic deformation is believed to be of a generic nature, because it was demonstrated for a variety of bioparticles of different sizes and for synthetic particles, for different ligand–receptor pairs (IgG–protein A, sugar–ConA, metal ion–chelating ligand), and when the deformation was caused by either external forces (mechanical deformation) or internal forces (the shrinkage of thermosensitive, macroporous hydrogel upon an increase in temperature). The elasticity of cryogel monoliths ensures high recovery of captured cells under mild conditions, with highly retained viability. This property, along with their continuous porous structure makes cryogel monoliths very attractive for applications in affinity cell separation. PMID:16418282

  16. Propagation of ultrasonic Love waves in nonhomogeneous elastic functionally graded materials.

    PubMed

    Kiełczyński, P; Szalewski, M; Balcerzak, A; Wieja, K

    2016-02-01

    This paper presents a theoretical study of the propagation behavior of ultrasonic Love waves in nonhomogeneous functionally graded elastic materials, which is a vital problem in the mechanics of solids. The elastic properties (shear modulus) of a semi-infinite elastic half-space vary monotonically with the depth (distance from the surface of the material). The Direct Sturm-Liouville Problem that describes the propagation of Love waves in nonhomogeneous elastic functionally graded materials is formulated and solved by using two methods: i.e., (1) Finite Difference Method, and (2) Haskell-Thompson Transfer Matrix Method. The dispersion curves of phase and group velocity of surface Love waves in inhomogeneous elastic graded materials are evaluated. The integral formula for the group velocity of Love waves in nonhomogeneous elastic graded materials has been established. The effect of elastic non-homogeneities on the dispersion curves of Love waves is discussed. Two Love wave waveguide structures are analyzed: (1) a nonhomogeneous elastic surface layer deposited on a homogeneous elastic substrate, and (2) a semi-infinite nonhomogeneous elastic half-space. Obtained in this work, the phase and group velocity dispersion curves of Love waves propagating in the considered nonhomogeneous elastic waveguides have not previously been reported in the scientific literature. The results of this paper may give a deeper insight into the nature of Love waves propagation in elastic nonhomogeneous functionally graded materials, and can provide theoretical guidance for the design and optimization of Love wave based devices. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. A design concept of parallel elasticity extracted from biological muscles for engineered actuators.

    PubMed

    Chen, Jie; Jin, Hongzhe; Iida, Fumiya; Zhao, Jie

    2016-08-23

    Series elastic actuation that takes inspiration from biological muscle-tendon units has been extensively studied and used to address the challenges (e.g. energy efficiency, robustness) existing in purely stiff robots. However, there also exists another form of passive property in biological actuation, parallel elasticity within muscles themselves, and our knowledge of it is limited: for example, there is still no general design strategy for the elasticity profile. When we look at nature, on the other hand, there seems a universal agreement in biological systems: experimental evidence has suggested that a concave-upward elasticity behaviour is exhibited within the muscles of animals. Seeking to draw possible design clues for elasticity in parallel with actuators, we use a simplified joint model to investigate the mechanisms behind this biologically universal preference of muscles. Actuation of the model is identified from general biological joints and further reduced with a specific focus on muscle elasticity aspects, for the sake of easy implementation. By examining various elasticity scenarios, one without elasticity and three with elasticity of different profiles, we find that parallel elasticity generally exerts contradictory influences on energy efficiency and disturbance rejection, due to the mechanical impedance shift thus caused. The trade-off analysis between them also reveals that concave parallel elasticity is able to achieve a more advantageous balance than linear and convex ones. It is expected that the results could contribute to our further understanding of muscle elasticity and provide a theoretical guideline on how to properly design parallel elasticity behaviours for engineering systems such as artificial actuators and robotic joints.

  18. Ab initio elastic tensor of cubic Ti0.5Al0.5N alloys: Dependence of elastic constants on size and shape of the supercell model and their convergence

    NASA Astrophysics Data System (ADS)

    Tasnádi, Ferenc; Odén, M.; Abrikosov, Igor A.

    2012-04-01

    In this study we discuss the performance of the special quasirandom structure (SQS) method in predicting the elastic properties of B1 (rocksalt) Ti0.5Al0.5N alloy. We use a symmetry-based projection technique, which gives the closest cubic approximate of the elastic tensor and allows us to align the SQSs of different shapes and sizes for a comparison in modeling elastic tensors. We show that the derived closest cubic approximate of the elastic tensor converges faster with respect to SQS size than the elastic tensor itself. That establishes a less demanding computational strategy to achieve convergence for the elastic constants. We determine the cubic elastic constants (Cij) and Zener's type elastic anisotropy (A) of Ti0.5Al0.5N. Optimal supercells, which capture accurately both the configurational disorder and cubic symmetry of elastic tensor, result in C11=447 GPa, C12=158 GPa, and C44=203 GPa with 3% of error and A=1.40 with 6% of error. In addition, we establish the general importance of selecting proper SQS with symmetry arguments to reliably model elasticity of alloys. We suggest the calculation of nine elastic tensor elements: C11, C22, C33, C12, C13, C23, C44, C55, and C66, to analyze the performance of SQSs and predict elastic constants of cubic alloys. The described methodology is general enough to be extended for alloys with other symmetry at arbitrary composition.

  19. Long-term xeno-free culture of human pluripotent stem cells on hydrogels with optimal elasticity.

    PubMed

    Higuchi, Akon; Kao, Shih-Hsuan; Ling, Qing-Dong; Chen, Yen-Ming; Li, Hsing-Fen; Alarfaj, Abdullah A; Munusamy, Murugan A; Murugan, Kadarkarai; Chang, Shih-Chang; Lee, Hsin-Chung; Hsu, Shih-Tien; Kumar, S Suresh; Umezawa, Akihiro

    2015-12-14

    The tentative clinical application of human pluripotent stem cells (hPSCs), such as human embryonic stem cells and human induced pluripotent stem cells, is restricted by the possibility of xenogenic contamination resulting from the use of mouse embryonic fibroblasts (MEFs) as a feeder layer. Therefore, we investigated hPSC cultures on biomaterials with different elasticities that were grafted with different nanosegments. We prepared dishes coated with polyvinylalcohol-co-itaconic acid hydrogels grafted with an oligopeptide derived from vitronectin (KGGPQVTRGDVFTMP) with elasticities ranging from 10.3 to 30.4 kPa storage moduli by controlling the crosslinking time. The hPSCs cultured on the stiffest substrates (30.4 kPa) tended to differentiate after five days of culture, whereas the hPSCs cultured on the optimal elastic substrates (25 kPa) maintained their pluripotency for over 20 passages under xeno-free conditions. These results indicate that cell culture matrices with optimal elasticity can maintain the pluripotency of hPSCs in culture.

  20. Supplementing biomechanical modeling with EMG analysis

    NASA Technical Reports Server (NTRS)

    Lewandowski, Beth; Jagodnik, Kathleen; Crentsil, Lawton; Humphreys, Bradley; Funk, Justin; Gallo, Christopher; Thompson, William; DeWitt, John; Perusek, Gail

    2016-01-01

    It is well established that astronauts experience musculoskeletal deconditioning when exposed to microgravity environments for long periods of time. Spaceflight exercise is used to counteract these effects, and the Advanced Resistive Exercise Device (ARED) on the International Space Station (ISS) has been effective in minimizing musculoskeletal losses. However, the exercise devices of the new exploration vehicles will have requirements of limited mass, power and volume. Because of these limitations, there is a concern that the exercise devices will not be as effective as ARED in maintaining astronaut performance. Therefore, biomechanical modeling is being performed to provide insight on whether the small Multi-Purpose Crew Vehicle (MPCV) device, which utilizes a single-strap design, will provide sufficient physiological loading to maintain musculoskeletal performance. Electromyography (EMG) data are used to supplement the biomechanical model results and to explore differences in muscle activation patterns during exercises using different loading configurations.

  1. Dose and elasticity of demand for self-administered cocaine in rats.

    PubMed

    Kearns, David N; Silberberg, Alan

    2016-04-01

    The present experiment tested whether the elasticity of demand for self-administered cocaine in rats is dose-dependent. Subjects lever pressed for three different doses of intravenous cocaine - 0.11, 0.33, and 1.0 mg/kg/infusion - on a demand procedure where the number of lever presses required per infusion increased within a session. The main finding was that demand for the 0.11 mg/kg dose was more elastic than it was for the two larger doses. There was no difference in demand elasticity between the 0.33 and 1.0 mg/kg doses. These results parallel findings previously reported in monkeys. The present study also demonstrated that a within-session procedure can be used to generate reliable demand curves.

  2. CAD-FEA modeling and analysis of different full crown monolithic restorations.

    PubMed

    Dal Piva, Amanda Maria de Oliveira; Tribst, João Paulo Mendes; Borges, Alexandre Luiz Souto; Souza, Rodrigo Othávio de Assunção E; Bottino, Marco Antonio

    2018-06-19

    To investigate the influence of different materials for monolithic full posterior crowns using 3D-Finite Element Analysis (FEA). Twelve (12) 3D models of adhesively-restored teeth with different crowns according to the material and its elastic modulus were analysed: Acrylic resin, Polyetheretherketone, Composite resin, Hybrid ceramic, pressable and machinable Zirconia reinforced lithium silicate, Feldspathic, Lithium disilicate, Gold alloy, Cobalt-Chromium alloy (Co-Cr), Zirconia tetragonal partially stabilized with yttria, and Alumina. All materials were assumed to behave elastically throughout the entire deformation. Results in restoration and cementing line were obtained using maximum principal stress. In addition, maximum shear stress criteria was used for the cementing line. Restorative materials with higher elastic modulus present higher stress concentration inside the crown, mainly tensile stress on an intaglio surface. On the other hand, materials with lower elastic modulus allow stress passage for cement, increasing shear stress on this layer. Stiffer materials promote higher stress peak values. Materials with higher elastic modulus such as Co-Cr, zirconia and alumina enable higher tensile stress concentration on the crown intaglio surface and higher shear stress on the cement layer, facilitating crown debonding. Copyright © 2018 The Academy of Dental Materials. Published by Elsevier Inc. All rights reserved.

  3. Torsion of a Cosserat elastic bar with square cross section: theory and experiment

    NASA Astrophysics Data System (ADS)

    Drugan, W. J.; Lakes, R. S.

    2018-04-01

    An approximate analytical solution for the displacement and microrotation vector fields is derived for pure torsion of a prismatic bar with square cross section comprised of homogeneous, isotropic linear Cosserat elastic material. This is accomplished by analytical simplification coupled with use of the principle of minimum potential energy together with polynomial representations for the desired field components. Explicit approximate expressions are derived for cross section warp and for applied torque versus angle of twist of the bar. These show that torsional rigidity exceeds the classical elasticity value, the difference being larger for slender bars, and that cross section warp is less than the classical amount. Experimental measurements on two sets of 3D printed square cross section polymeric bars, each set having a different microstructure and four different cross section sizes, revealed size effects not captured by classical elasticity but consistent with the present analysis for physically sensible values of the Cosserat moduli. The warp can allow inference of Cosserat elastic constants independently of any sensitivity the material may have to dilatation gradients; warp also facilitates inference of Cosserat constants that are difficult to obtain via size effects.

  4. Comparison of four different techniques to evaluate the elastic properties of phantom in elastography: is there a gold standard?

    NASA Astrophysics Data System (ADS)

    Oudry, Jennifer; Lynch, Ted; Vappou, Jonathan; Sandrin, Laurent; Miette, Véronique

    2014-10-01

    Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young’s modulus over the range of normal and cirrhotic liver stiffnesses. The Young’s modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.

  5. Comparison of four different techniques to evaluate the elastic properties of phantom in elastography: is there a gold standard?

    PubMed

    Oudry, Jennifer; Lynch, Ted; Vappou, Jonathan; Sandrin, Laurent; Miette, Véronique

    2014-10-07

    Elastographic techniques used in addition to imaging techniques (ultrasound, resonance magnetic or optical) provide new clinical information on the pathological state of soft tissues. However, system-dependent variation in elastographic measurements may limit the clinical utility of these measurements by introducing uncertainty into the measurement. This work is aimed at showing differences in the evaluation of the elastic properties of phantoms performed by four different techniques: quasi-static compression, dynamic mechanical analysis, vibration-controlled transient elastography and hyper-frequency viscoelastic spectroscopy. Four Zerdine® gel materials were tested and formulated to yield a Young's modulus over the range of normal and cirrhotic liver stiffnesses. The Young's modulus and the shear wave speed obtained with each technique were compared. Results suggest a bias in elastic property measurement which varies with systems and highlight the difficulty in finding a reference method to determine and assess the elastic properties of tissue-mimicking materials. Additional studies are needed to determine the source of this variation, and control for them so that accurate, reproducible reference standards can be made for the absolute measurement of soft tissue elasticity.

  6. Biomechanically based simulation of brain deformations for intraoperative image correction: coupling of elastic and fluid models

    NASA Astrophysics Data System (ADS)

    Hagemann, Alexander; Rohr, Karl; Stiehl, H. Siegfried

    2000-06-01

    In order to improve the accuracy of image-guided neurosurgery, different biomechanical models have been developed to correct preoperative images w.r.t. intraoperative changes like brain shift or tumor resection. All existing biomechanical models simulate different anatomical structures by using either appropriate boundary conditions or by spatially varying material parameter values, while assuming the same physical model for all anatomical structures. In general, this leads to physically implausible results, especially in the case of adjacent elastic and fluid structures. Therefore, we propose a new approach which allows to couple different physical models. In our case, we simulate rigid, elastic, and fluid regions by using the appropriate physical description for each material, namely either the Navier equation or the Stokes equation. To solve the resulting differential equations, we derive a linear matrix system for each region by applying the finite element method (FEM). Thereafter, the linear matrix systems are linked together, ending up with one overall linear matrix system. Our approach has been tested using synthetic as well as tomographic images. It turns out from experiments, that the integrated treatment of rigid, elastic, and fluid regions significantly improves the prediction results in comparison to a pure linear elastic model.

  7. Local interaction simulation approach to modelling nonclassical, nonlinear elastic behavior in solids.

    PubMed

    Scalerandi, Marco; Agostini, Valentina; Delsanto, Pier Paolo; Van Den Abeele, Koen; Johnson, Paul A

    2003-06-01

    Recent studies show that a broad category of materials share "nonclassical" nonlinear elastic behavior much different from "classical" (Landau-type) nonlinearity. Manifestations of "nonclassical" nonlinearity include stress-strain hysteresis and discrete memory in quasistatic experiments, and specific dependencies of the harmonic amplitudes with respect to the drive amplitude in dynamic wave experiments, which are remarkably different from those predicted by the classical theory. These materials have in common soft "bond" elements, where the elastic nonlinearity originates, contained in hard matter (e.g., a rock sample). The bond system normally comprises a small fraction of the total material volume, and can be localized (e.g., a crack in a solid) or distributed, as in a rock. In this paper a model is presented in which the soft elements are treated as hysteretic or reversible elastic units connected in a one-dimensional lattice to elastic elements (grains), which make up the hard matrix. Calculations are performed in the framework of the local interaction simulation approach (LISA). Experimental observations are well predicted by the model, which is now ready both for basic investigations about the physical origins of nonlinear elasticity and for applications to material damage diagnostics.

  8. Elastic cartilage reconstruction by transplantation of cultured hyaline cartilage-derived chondrocytes.

    PubMed

    Mizuno, M; Takebe, T; Kobayashi, S; Kimura, S; Masutani, M; Lee, S; Jo, Y H; Lee, J I; Taniguchi, H

    2014-05-01

    Current surgical intervention of craniofacial defects caused by injuries or abnormalities uses reconstructive materials, such as autologous cartilage grafts. Transplantation of autologous tissues, however, places a significant invasiveness on patients, and many efforts have been made for establishing an alternative graft. Recently, we and others have shown the potential use of reconstructed elastic cartilage from ear-derived chondrocytes or progenitors with the unique elastic properties. Here, we examined the differentiation potential of canine joint cartilage-derived chondrocytes into elastic cartilage for expanding the cell sources, such as hyaline cartilage. Articular chondrocytes are isolated from canine joint, cultivated, and compared regarding characteristic differences with auricular chondrocytes, including proliferation rates, gene expression, extracellular matrix production, and cartilage reconstruction capability after transplantation. Canine articular chondrocytes proliferated less robustly than auricular chondrocytes, but there was no significant difference in the amount of sulfated glycosaminoglycan produced from redifferentiated chondrocytes. Furthermore, in vitro expanded and redifferentiated articular chondrocytes have been shown to reconstruct elastic cartilage on transplantation that has histologic characteristics distinct from hyaline cartilage. Taken together, cultured hyaline cartilage-derived chondrocytes are a possible cell source for elastic cartilage reconstruction. Crown Copyright © 2014. Published by Elsevier Inc. All rights reserved.

  9. Elastic Properties of Chimpanzee Craniofacial Cortical Bone.

    PubMed

    Gharpure, Poorva; Kontogiorgos, Elias D; Opperman, Lynne A; Ross, Callum F; Strait, David S; Smith, Amanda; Pryor, Leslie C; Wang, Qian; Dechow, Paul C

    2016-12-01

    Relatively few assessments of cranial biomechanics formally take into account variation in the material properties of cranial cortical bone. Our aim was to characterize the elastic properties of chimpanzee craniofacial cortical bone and compare these to the elastic properties of dentate human craniofacial cortical bone. From seven cranial regions, 27 cylindrical samples were harvested from each of five chimpanzee crania. Assuming orthotropy, axes of maximum stiffness in the plane of the cortical plate were derived using modified equations of Hooke's law in a Mathcad program. Consistent orientations among individuals were observed in the zygomatic arch and alveolus. The density of cortical bone showed significant regional variation (P < 0.001). The elastic moduli demonstrated significant differences between sites, and a distinct pattern where E 3  > E 2  > E 1 . Shear moduli were significantly different among regions (P < 0.001). The pattern by which chimpanzee cranial cortical bone varies in elastic properties resembled that seen in humans, perhaps suggesting that the elastic properties of craniofacial bone in fossil hominins can be estimated with at least some degree of confidence. Anat Rec, 299:1718-1733, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  10. A general one-dimension nonlinear magneto-elastic coupled constitutive model for magnetostrictive materials

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhang, Da-Guang; Li, Meng-Han; Zhou, Hao-Miao, E-mail: zhouhm@cjlu.edu.cn

    2015-10-15

    For magnetostrictive rods under combined axial pre-stress and magnetic field, a general one-dimension nonlinear magneto-elastic coupled constitutive model was built in this paper. First, the elastic Gibbs free energy was expanded into polynomial, and the relationship between stress and strain and the relationship between magnetization and magnetic field with the polynomial form were obtained with the help of thermodynamic relations. Then according to microscopic magneto-elastic coupling mechanism and some physical facts of magnetostrictive materials, a nonlinear magneto-elastic constitutive with concise form was obtained when the relations of nonlinear strain and magnetization in the polynomial constitutive were instead with transcendental functions.more » The comparisons between the prediction and the experimental data of different magnetostrictive materials, such as Terfenol-D, Metglas and Ni showed that the predicted magnetostrictive strain and magnetization curves were consistent with experimental results under different pre-stresses whether in the region of low and moderate field or high field. Moreover, the model can fully reflect the nonlinear magneto-mechanical coupling characteristics between magnetic, magnetostriction and elasticity, and it can effectively predict the changes of material parameters with pre-stress and bias field, which is useful in practical applications.« less

  11. METABOLIC SYNDROME AND ARTERIAL ELASTICITY IN YOUTH

    PubMed Central

    Gardner, Andrew W.; Parker, Donald E.; Krishnan, Sowmya; Chalmers, Laura J.

    2012-01-01

    Objective To compare arterial elasticity in children, adolescents, and young adults with and without metabolic syndrome (MetS), and to assess which MetS components, demographic measures, and body composition measures are associated with arterial elasticity. Materials/Methods Two-hundred six subjects (107 females and 99 males) between the ages of 10 and 20 years were recruited by local newspaper advertisements, university email advertisements, and informational flyers. Subjects were assessed on MetS components, demographic measures, body composition measures, and arterial elasticity via radial tonometry. Forty-five subjects (22%) had MetS, as defined by the International Diabetes Federation, and 161 subjects (78%) did not. Results The primary novel finding was that group differences were not observed for large artery elasticity index (LAEI) (MetS = 16.1±4.4 (ml × mmHg−1) × 10 (mean±SD), control = 15.4±4.9, (ml × mmHg−1) × 10, p=0.349), and small artery elasticity index (SAEI) (MetS = 9.2±2.7 (ml × mmHg−1) × 100, control = 8.4±2.9, (ml × mmHg−1) × 100, p=0.063). In the MetS group, fat free mass was positively associated with arterial elasticity, and was the strongest multivariate predictor of LAEI (partial R2=0.41) and SAEI (partial R2=0.41). Conclusions Youth with MetS did not exhibit differences in LAEI and SAEI compared to controls. Furthermore, fat free mass of youth with MetS was positively associated with arterial elasticity, and was the strongest predictor of both LAEI and SAEI. The clinical implication is that exercise intervention designed to increase fat free mass might increase arterial elasticity in youth, particularly in youth with MetS. PMID:23142161

  12. Core Muscle Activity, Exercise Preference, and Perceived Exertion during Core Exercise with Elastic Resistance versus Machine.

    PubMed

    Vinstrup, Jonas; Sundstrup, Emil; Brandt, Mikkel; Jakobsen, Markus D; Calatayud, Joaquin; Andersen, Lars L

    2015-01-01

    Objectives. To investigate core muscle activity, exercise preferences, and perceived exertion during two selected core exercises performed with elastic resistance versus a conventional training machine. Methods. 17 untrained men aged 26-67 years participated in surface electromyography (EMG) measurements of five core muscles during torso-twists performed from left to right with elastic resistance and in the machine, respectively. The order of the exercises was randomized and each exercise consisted of 3 repetitions performed at a 10 RM load. EMG amplitude was normalized (nEMG) to maximum voluntary isometric contraction (MVC). Results. A higher right erector spinae activity in the elastic exercise compared with the machine exercise (50% [95% CI 36-64] versus 32% [95% CI 18-46] nEMG) was found. By contrast, the machine exercise, compared with the elastic exercise, showed higher left external oblique activity (77% [95% CI 64-90] versus 54% [95% CI 40-67] nEMG). For the rectus abdominis, right external oblique, and left erector spinae muscles there were no significant differences. Furthermore, 76% preferred the torso-twist with elastic resistance over the machine exercise. Perceived exertion (Borg CR10) was not significantly different between machine (5.8 [95% CI 4.88-6.72]) and elastic exercise (5.7 [95% CI 4.81-6.59]). Conclusion. Torso-twists using elastic resistance showed higher activity of the erector spinae, whereas torso-twist in the machine resulted in higher activity of the external oblique. For the remaining core muscles the two training modalities induced similar muscular activation. In spite of similar perceived exertion the majority of the participants preferred the exercise using elastic resistance.

  13. Elastic behavior of brain simulants in comparison to porcine brain at different loading velocities.

    PubMed

    Falland-Cheung, Lisa; Scholze, Mario; Hammer, Niels; Waddell, J Neil; Tong, Darryl C; Brunton, Paul A

    2018-01-01

    Blunt force impacts to the head and the resulting internal force transmission to the brain and other cranial tissue are difficult to measure. To model blunt force impact scenarios, the compressive properties resembling tissue elasticity are of importance. Therefore, this study investigated and compared the elastic behavior of gelatin, alginate, agar/glycerol and agar/glycerol/water simulant materials to that of porcine brain in a fresh and unfixed condition. Specimens, 10 × 10 × 10mm 3 , were fabricated and tested at 22°C, apart from gelatin which was conditioned to 4°C prior to testing. For comparison, fresh porcine brains were sourced and prepared to the same dimensions as the simulants. Specimens underwent compression tests at crosshead displacement rates of 2.5, 10 and 16mms -1 (equivalent to strain rates of 0.25, 1 and 1.6s -1 ), obtaining apparent elastic moduli values at different strain rate intervals (0-0.2, 0.2-0.4 and 0.4-0.5). The results of this study indicate that overall all simulant materials had an apparent elastic moduli similar in magnitude across all strain ranges compared to brain, even though comparatively higher, especially the apparent elastic moduli values of alginate. In conclusion, while agar/glycerol/water and agar/glycerol had similar apparent elastic moduli in magnitude and the closest apparent elastic moduli in the initial strain range (E 1 ), gelatin showed the most similar values to fresh porcine brain at the transitional (E 2 ) and higher strain range (E 3 ). The simulant materials and the fresh porcine brain exhibited strain rate dependent behavior, with increasing elastic moduli upon increasing loading velocities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Third-order elastic constants of diamond determined from experimental data

    DOE PAGES

    Winey, J. M.; Hmiel, A.; Gupta, Y. M.

    2016-06-01

    The pressure derivatives of the second-order elastic constants (SOECs) of diamond were determined by analyzing previous sound velocity measurements under hydrostatic stress [McSkimin and Andreatch, J. Appl. Phys. 43, 294 (1972)]. Furthermore, our analysis corrects an error in the previously reported results.We present a complete and corrected set of third-order elastic constants (TOECs) using the corrected pressure derivatives, together with published data for the nonlinear elastic response of shock compressed diamond [Lang and Gupta, Phys. Rev. Lett. 106, 125502 (2011)] and it differs significantly from TOECs published previously.

  15. Stress fields and energy of disclination-type defects in zones of localized elastic distortions

    NASA Astrophysics Data System (ADS)

    Sukhanov, Ivan I.; Tyumentsev, Alexander N.; Ditenberg, Ivan A.

    2016-11-01

    This paper studies theoretically the elastically deformed state and analyzes deformation mechanisms in nanocrystals in the zones of localized elastic distortions and related disclination-type defects, such as dipole, quadrupole and multipole of partial disclinations. Significant differences in the energies of quadrupole and multipole configurations in comparison with nanodipole are revealed. The mechanism of deformation localization in the field of elastic distortions is proposed, which is a quasi-periodic sequence of formation and relaxation of various disclination ensembles with a periodic change in the energy of the defect.

  16. Tendon elasticity and muscle function.

    PubMed

    Alexander, R McNeill

    2002-12-01

    Vertebrate animals exploit the elastic properties of their tendons in several different ways. Firstly, metabolic energy can be saved in locomotion if tendons stretch and then recoil, storing and returning elastic strain energy, as the animal loses and regains kinetic energy. Leg tendons save energy in this way when birds and mammals run, and an aponeurosis in the back is also important in galloping mammals. Tendons may have similar energy-saving roles in other modes of locomotion, for example in cetacean swimming. Secondly, tendons can recoil elastically much faster than muscles can shorten, enabling animals to jump further than they otherwise could. Thirdly, tendon elasticity affects the control of muscles, enhancing force control at the expense of position control.

  17. Damage of the Interface Between an Orthodontic Bracket and Enamel - the Effect of Some Elastic Properties of the Adhesive Material

    NASA Astrophysics Data System (ADS)

    Durgesh, B. H.; Alkheraif, A. A.; Al Sharawy, M.; Varrela, J.; Vallittu, P. K.

    2016-01-01

    The aim of this study was to investigate the magnitude of debonding stress of an orthodontic bracket bonded to the enamel with resin systems having different elastic properties. For the same purpose, sixty human premolars were randomly divided into four groups according to the adhesive system used for bonding brackets: G Fix flowable resin (GFI) with Everstick NET (ESN), GFI, G Aenial Universal Flow (GAU) with ESN, and GAU. The brackets were stressed in the occlusogingival direction on a universal testing machine. The values of debonding load and displacement were determined at the point of debonding. The elastic modulus of the tested materials was determined using nanoindentation. An analysis of variance showed a significant difference in the loads required to debond the bracket among the groups tested. The GAU group had the highest elastic modulus, followed by the GFI and ESN groups. ARI (Adhesive Remnant Index) scores demonstrated more remnants of the adhesive material on the bracket surface with adhesives having a higher elastic modulus. Taking into consideration results of the present in-vitro study, it can be concluded that the incorporation of a glass-fiber-reinforced composite resin (FRC) with a low elastic modulus between the orthodontic bracket and enamel increases the debonding force and strain more than with adhesive systems having a higher elastic modulus.

  18. Correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise

    PubMed Central

    Yoon, Jung-Gyu

    2018-01-01

    [Purpose] The purpose of this study was to examine correlations between measurement time and different expansibility of the elastic tape on the rectus femoris and body sway index with plyometric exercise. [Subjects and Methods] The subjects of this study were 24 healthy men. C90 area, C90 angle, trace length, sway average velocity for body sway index were measured using a force plate by BT4. The collected data were analyzed using Kendall’s coefficient of concordance. [Results] All of body sway index on measuring follow up 24 hours after removing tape were significantly decreased than before and right after plyometric exercise. No significant correlations were found between body sway index and different expansibility of the elastic tape. [Conclusion] It appears that different expansibility of the elastic tape does not affect the ability to body sway index. Carry over effect of taping was verified on measuring follow up 24 hours after removing tape through the decreasing body sway index. PMID:29410564

  19. The Effects of 24 weeks of Resistance Training with Simultaneous Elastic and Free Weight Loading on Muscular Performance of Novice Lifters.

    PubMed

    Shoepe, Todd C; Ramirez, David A; Rovetti, Robert J; Kohler, David R; Almstedt, Hawley C

    2011-09-01

    The purpose of this investigation was to assess the effectiveness of variable resistance as provided through elastic plus free weight techniques in college aged males and females. Twenty novice lifters were randomly assigned to a traditional free weight only (6 males and 5 females) or elastic band plus free weight group (5 males and 5 females) and 9 more normally active controls (5 males and 4 females), were recruited to maintain normal activity for the duration of the study. No differences existed between control, free weight and elastic band at baseline for age, body height, body mass, body mass index, and body fat percentage. One-repetition maximums were performed for squat and bench press while both strength and power were assessed using isokinetic dynamometry. Elastic groups and free-weight groups completed 24 weeks of whole body, periodized, high intensity resistance (65-95% of one-repetition maximum) training three times/week. Training programs were identical except that the elastic group trained the barbell squat, bench press and stiff-legged deadlift with 20-35% of their total prescribed training loads coming from band resistance (assessed at the top of the range of motion) with the remainder from free weight resistance. A mixed-model analysis revealed that peak torque, average power and one-repetition maximums for squat were significantly greater after training for the elastic group compared to the control (p<0.05). In addition, the free weight group also showed significantly greater improvements over the control in peak torque and one-repetition maximums for squat and bench press. No significant differences were observed between the elastic band and free weight groups. Combined variable elastic band plus free weight exercises are effective at increasing strength and power similar to free-weights alone in novice college aged males and females. However, due to complexity in set-up and load assignment elastic adoption by novice lifters in an unsupervised situation is not advised.

  20. Dose-dependent collagen cross-linking of rabbit scleral tissue by blue light and riboflavin treatment probed by dynamic shear rheology.

    PubMed

    Schuldt, Carsten; Karl, Anett; Körber, Nicole; Koch, Christian; Liu, Qing; Fritsch, Anatol W; Reichenbach, Andreas; Wiedemann, Peter; Käs, Josef A; Francke, Mike; Iseli, Hans Peter

    2015-08-01

    To determine the visco-elastic properties of isolated rabbit scleral tissue and dose-dependent biomechanical and morphological changes after collagen cross-linking by riboflavin/blue light treatment. Scleral patches from 87 adult albino rabbit eyes were examined by dynamic shear rheology. Scleral patches were treated by riboflavin and different intensities of blue light (450 nm), and the impact on the visco-elastic properties was determined by various rheological test regimes. The relative elastic modulus was calculated from non-treated and corresponding treated scleral patches, and treatments with different blue light intensities were compared. Shear rheology enables us to study the material properties of scleral tissue within physiological relevant parameters. Cross-linking treatment increased the viscous as well as the elastic modulus and changed the ratio of the elastic versus viscous proportion in scleral tissue. Constant riboflavin application combined with different blue light intensities from 12 mW/cm(2) up to 100 mW/cm(2) increased the relative elastic modulus of scleral tissue by factors up to 1.8. Further enhancement of the applied light intensity caused a decline of the relative elastic modulus. This might be due to destructive changes of the collagen bundle structure at larger light intensities, as observed by histological examination. Collagen cross-linking by riboflavin/blue light application increases the biomechanical stiffness of the sclera in a dose-dependent manner up to certain light intensities. Therefore, this treatment might be a suitable therapeutic approach to stabilize the biomechanical properties of scleral tissue in cases of pathological eye expansion. © 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.

Top