Sample records for elbow joint angles

  1. Kinematic functions for the 7 DOF robotics research arm

    NASA Technical Reports Server (NTRS)

    Kreutz, K.; Long, M.; Seraji, Homayoun

    1989-01-01

    The Robotics Research Model K-1207 manipulator is a redundant 7R serial link arm with offsets at all joints. To uniquely determine joint angles for a given end-effector configuration, the redundancy is parameterized by a scalar variable which corresponds to the angle between the manipulator elbow plane and the vertical plane. The forward kinematic mappings from joint-space to end-effector configuration and elbow angle, and the augmented Jacobian matrix which gives end-effector and elbow angle rates as a function of joint rates, are also derived.

  2. Elbow joint angle and elbow movement velocity estimation using NARX-multiple layer perceptron neural network model with surface EMG time domain parameters.

    PubMed

    Raj, Retheep; Sivanandan, K S

    2017-01-01

    Estimation of elbow dynamics has been the object of numerous investigations. In this work a solution is proposed for estimating elbow movement velocity and elbow joint angle from Surface Electromyography (SEMG) signals. Here the Surface Electromyography signals are acquired from the biceps brachii muscle of human hand. Two time-domain parameters, Integrated EMG (IEMG) and Zero Crossing (ZC), are extracted from the Surface Electromyography signal. The relationship between the time domain parameters, IEMG and ZC with elbow angular displacement and elbow angular velocity during extension and flexion of the elbow are studied. A multiple input-multiple output model is derived for identifying the kinematics of elbow. A Nonlinear Auto Regressive with eXogenous inputs (NARX) structure based multiple layer perceptron neural network (MLPNN) model is proposed for the estimation of elbow joint angle and elbow angular velocity. The proposed NARX MLPNN model is trained using Levenberg-marquardt based algorithm. The proposed model is estimating the elbow joint angle and elbow movement angular velocity with appreciable accuracy. The model is validated using regression coefficient value (R). The average regression coefficient value (R) obtained for elbow angular displacement prediction is 0.9641 and for the elbow anglular velocity prediction is 0.9347. The Nonlinear Auto Regressive with eXogenous inputs (NARX) structure based multiple layer perceptron neural networks (MLPNN) model can be used for the estimation of angular displacement and movement angular velocity of the elbow with good accuracy.

  3. Flexor bias of joint position in humans during spaceflight

    NASA Technical Reports Server (NTRS)

    McCall, G. E.; Goulet, C.; Boorman, G. I.; Roy, R. R.; Edgerton, V. R.

    2003-01-01

    The ability to estimate ankle and elbow joint position was tested before, during, and after a 17-day spaceflight. Subjects estimated targeted joint angles during isovelocity (IsoV) joint movements with agonist muscle groups either active or relaxed. These movements included elbow extension (EE) and elbow flexion (EF), and plantarflexion (PF) and dorsiflexion (DF) of the ankle. Subjects also estimated these joint positions while moving the dynamometer at their chosen (variable) velocity (VarV) during EE and PF. For IsoV tests, no differences were observed between active and passive movements for either the ankle or elbow. Compared with those of pre-flight test days, estimates of targeted elbow joint angles were approximately 5 degrees to 15 degrees more flexed in-flight, and returned toward the pre-flight values during recovery. The spaceflight effects for the ankle were inconsistent and less prevalent than those for the elbow. The VarV PF test condition for the 120 degrees target angle at the ankle exhibited approximately 5 degrees to 7 degrees more DF target angle estimates in-flight compared with those pre- or post-flight. In contrast, during IsoV PF there was a tendency for ankle estimates to be approximately 2 degrees to 3 degrees more PF after 2-3 days exposure to spaceflight. These data indicate that during spaceflight the perception of elbow extension is greater than actuality, and are consistent with the interpretation that microgravity induced a flexor bias in the estimation of the actual elbow joint position. Moreover, these effects in joint proprioception during spaceflight were observed in individual isolated single-joint movements during tasks in which vestibular function in maintaining posture were minimal.

  4. Flexor bias of joint position in humans during spaceflight.

    PubMed

    McCall, G E; Goulet, C; Boorman, G I; Roy, R R; Edgerton, V R

    2003-09-01

    The ability to estimate ankle and elbow joint position was tested before, during, and after a 17-day spaceflight. Subjects estimated targeted joint angles during isovelocity (IsoV) joint movements with agonist muscle groups either active or relaxed. These movements included elbow extension (EE) and elbow flexion (EF), and plantarflexion (PF) and dorsiflexion (DF) of the ankle. Subjects also estimated these joint positions while moving the dynamometer at their chosen (variable) velocity (VarV) during EE and PF. For IsoV tests, no differences were observed between active and passive movements for either the ankle or elbow. Compared with those of pre-flight test days, estimates of targeted elbow joint angles were approximately 5 degrees to 15 degrees more flexed in-flight, and returned toward the pre-flight values during recovery. The spaceflight effects for the ankle were inconsistent and less prevalent than those for the elbow. The VarV PF test condition for the 120 degrees target angle at the ankle exhibited approximately 5 degrees to 7 degrees more DF target angle estimates in-flight compared with those pre- or post-flight. In contrast, during IsoV PF there was a tendency for ankle estimates to be approximately 2 degrees to 3 degrees more PF after 2-3 days exposure to spaceflight. These data indicate that during spaceflight the perception of elbow extension is greater than actuality, and are consistent with the interpretation that microgravity induced a flexor bias in the estimation of the actual elbow joint position. Moreover, these effects in joint proprioception during spaceflight were observed in individual isolated single-joint movements during tasks in which vestibular function in maintaining posture were minimal.

  5. Feasibility study of using a Microsoft Kinect for virtual coaching of wheelchair transfer techniques.

    PubMed

    Hwang, Seonhong; Tsai, Chung-Ying; Koontz, Alicia M

    2017-05-24

    The purpose of this study was to test the concurrent validity and test-retest reliability of the Kinect skeleton tracking algorithm for measurement of trunk, shoulder, and elbow joint angle measurement during a wheelchair transfer task. Eight wheelchair users were recruited for this study. Joint positions were recorded simultaneously by the Kinect and Vicon motion capture systems while subjects transferred from their wheelchairs to a level bench. Shoulder, elbow, and trunk angles recorded with the Kinect system followed a similar trajectory as the angles recorded with the Vicon system with correlation coefficients that are larger than 0.71 on both sides (leading arm and trailing arm). The root mean square errors (RMSEs) ranged from 5.18 to 22.46 for the shoulder, elbow, and trunk angles. The 95% limits of agreement (LOA) for the discrepancy between the two systems exceeded the clinical significant level of 5°. For the trunk, shoulder, and elbow angles, the Kinect had very good relative reliability for the measurement of sagittal, frontal and horizontal trunk angles, as indicated by the high intraclass correlation coefficient (ICC) values (>0.90). Small standard error of the measure (SEM) values, indicating good absolute reliability, were observed for all joints except for the leading arm's shoulder joint. Relatively large minimal detectable changes (MDCs) were observed in all joint angles. The Kinect motion tracking has promising performance levels for some upper limb joints. However, more accurate measurement of the joint angles may be required. Therefore, understanding the limitations in precision and accuracy of Kinect is imperative before utilization of Kinect.

  6. Where is your arm? Variations in proprioception across space and tasks.

    PubMed

    Fuentes, Christina T; Bastian, Amy J

    2010-01-01

    The sense of limb position is crucial for movement control and environmental interactions. Our understanding of this fundamental proprioceptive process, however, is limited. For example, little is known about the accuracy of arm proprioception: Does it vary with changes in arm configuration, since some peripheral receptors are engaged only when joints move toward extreme angles? Are these variations consistent across different tasks? Does proprioceptive ability change depending on what we try to localize (e.g., fingertip position vs. elbow angle)? We used a robot exoskeleton to study proprioception in 14 arm configurations across three tasks, asking healthy subjects to 1) match a pointer to elbow angles after passive movements, 2) match a pointer to fingertip positions after passive movements, and 3) actively match their elbow angle to a pointer. Across all three tasks, subjects overestimated more extreme joint positions; this may be due to peripheral sensory signals biasing estimates as a safety mechanism to prevent injury. We also found that elbow angle estimates were more precise when used to judge fingertip position versus directly reported, suggesting that the brain has better access to limb endpoint position than joint angles. Finally, precision of elbow angle estimates improved in active versus passive movements, corroborating work showing that efference copies of motor commands and alpha-gamma motor neuron coactivation contribute to proprioceptive estimates. In sum, we have uncovered fundamental aspects of normal proprioceptive processing, demonstrating not only predictable biases that are dependent on joint configuration and independent of task but also improved precision when integrating information across joints.

  7. Effect of window length on performance of the elbow-joint angle prediction based on electromyography

    NASA Astrophysics Data System (ADS)

    Triwiyanto; Wahyunggoro, Oyas; Adi Nugroho, Hanung; Herianto

    2017-05-01

    The high performance of the elbow joint angle prediction is essential on the development of the devices based on electromyography (EMG) control. The performance of the prediction depends on the feature of extraction parameters such as window length. In this paper, we evaluated the effect of the window length on the performance of the elbow-joint angle prediction. The prediction algorithm consists of zero-crossing feature extraction and second order of Butterworth low pass filter. The feature was used to extract the EMG signal by varying window length. The EMG signal was collected from the biceps muscle while the elbow was moved in the flexion and extension motion. The subject performed the elbow motion by holding a 1-kg load and moved the elbow in different periods (12 seconds, 8 seconds and 6 seconds). The results indicated that the window length affected the performance of the prediction. The 250 window lengths yielded the best performance of the prediction algorithm of (mean±SD) root mean square error = 5.68%±1.53% and Person’s correlation = 0.99±0.0059.

  8. Accuracy of visual estimates of joint angle and angular velocity using criterion movements.

    PubMed

    Morrison, Craig S; Knudson, Duane; Clayburn, Colby; Haywood, Philip

    2005-06-01

    A descriptive study to document undergraduate physical education majors' (22.8 +/- 2.4 yr. old) estimates of sagittal plane elbow angle and angular velocity of elbow flexion visually was performed. 42 subjects rated videotape replays of 30 movements organized into three speeds of movement and two criterion elbow angles. Video images of the movements were analyzed with Peak Motus to measure actual values of elbow angles and peak angular velocity. Of the subjects 85.7% had speed ratings significantly correlated with true peak elbow angular velocity in all three angular velocity conditions. Few (16.7%) subjects' ratings of elbow angle correlated significantly with actual angles. Analysis of the subjects with good ratings showed the accuracy of visual ratings was significantly related to speed, with decreasing accuracy for slower speeds of movement. The use of criterion movements did not improve the small percentage of novice observers who could accurately estimate body angles during movement.

  9. The effects of grip width on sticking region in bench press.

    PubMed

    Gomo, Olav; Van Den Tillaar, Roland

    2016-01-01

    The aim of this study was to examine the occurrence of the sticking region by examining how three different grip widths affect the sticking region in powerlifters' bench press performance. It was hypothesised that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width, indicating a poor mechanical region for vertical force production at these joint angles. Twelve male experienced powerlifters (age 27.7 ± 8.8 years, mass 91.9 ± 15.4 kg) were tested in one repetition maximum (1-RM) bench press with a narrow, medium and wide grip. Joint kinematics, timing, bar position and velocity were measured with a 3D motion capture system. All participants showed a clear sticking region with all three grip widths, but this sticking region was not found to occur at the same joint angles in all three grip widths, thereby rejecting the hypothesis that the sticking region would occur at the same joint angle of the elbow and shoulder independent of grip width. It is suggested that, due to the differences in moment arm of the barbell about the elbow joint in the sticking region, there still might be a poor mechanical region for total force production that is joint angle-specific.

  10. Quantification of shoulder and elbow passive moments in the sagittal plane as a function of adjacent angle fixations.

    PubMed

    Kodek, Timotej; Munih, Marko

    2003-01-01

    The goal of this study was an assessment of the shoulder and elbow joint passive moments in the sagittal plane for six healthy individuals. Either the shoulder or elbow joints were moved at a constant speed, very slowly throughout a large portion of their range by means of an industrial robot. During the whole process the arm was held fully passively, while the end point force data and the shoulder, elbow and wrist angle data were collected. The presented method unequivocally reveals a large passive moment adjacent angle dependency in the central angular range, where most everyday actions are performed. It is expected to prove useful in the future work when examining subjects with neuromuscular disorders. Their passive moments may show a fully different pattern than the ones obtained in this study.

  11. Quantitative evaluation of toothbrush and arm-joint motion during tooth brushing.

    PubMed

    Inada, Emi; Saitoh, Issei; Yu, Yong; Tomiyama, Daisuke; Murakami, Daisuke; Takemoto, Yoshihiko; Morizono, Ken; Iwasaki, Tomonori; Iwase, Yoko; Yamasaki, Youichi

    2015-07-01

    It is very difficult for dental professionals to objectively assess tooth brushing skill of patients, because an obvious index to assess the brushing motion of patients has not been established. The purpose of this study was to quantitatively evaluate toothbrush and arm-joint motion during tooth brushing. Tooth brushing motion, performed by dental hygienists for 15 s, was captured using a motion-capture system that continuously calculates the three-dimensional coordinates of object's motion relative to the floor. The dental hygienists performed the tooth brushing on the buccal and palatal sides of their right and left upper molars. The frequencies and power spectra of toothbrush motion and joint angles of the shoulder, elbow, and wrist were calculated and analyzed statistically. The frequency of toothbrush motion was higher on the left side (both buccal and palatal areas) than on the right side. There were no significant differences among joint angle frequencies within each brushing area. The inter- and intra-individual variations of the power spectrum of the elbow flexion angle when brushing were smaller than for any of the other angles. This study quantitatively confirmed that dental hygienists have individual distinctive rhythms during tooth brushing. All arm joints moved synchronously during brushing, and tooth brushing motion was controlled by coordinated movement of the joints. The elbow generated an individual's frequency through a stabilizing movement. The shoulder and wrist control the hand motion, and the elbow generates the cyclic rhythm during tooth brushing.

  12. A hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements

    NASA Astrophysics Data System (ADS)

    Kawase, Toshihiro; Sakurada, Takeshi; Koike, Yasuharu; Kansaku, Kenji

    2017-02-01

    Objective. Brain-machine interface (BMI) technologies have succeeded in controlling robotic exoskeletons, enabling some paralyzed people to control their own arms and hands. We have developed an exoskeleton asynchronously controlled by EEG signals. In this study, to enable real-time control of the exoskeleton for paresis, we developed a hybrid system with EEG and EMG signals, and the EMG signals were used to estimate its joint angles. Approach. Eleven able-bodied subjects and two patients with upper cervical spinal cord injuries (SCIs) performed hand and arm movements, and the angles of the metacarpophalangeal (MP) joint of the index finger, wrist, and elbow were estimated from EMG signals using a formula that we derived to calculate joint angles from EMG signals, based on a musculoskeletal model. The formula was exploited to control the elbow of the exoskeleton after automatic adjustments. Four able-bodied subjects and a patient with upper cervical SCI wore an exoskeleton controlled using EMG signals and were required to perform hand and arm movements to carry and release a ball. Main results. Estimated angles of the MP joints of index fingers, wrists, and elbows were correlated well with the measured angles in 11 able-bodied subjects (correlation coefficients were 0.81  ±  0.09, 0.85  ±  0.09, and 0.76  ±  0.13, respectively) and the patients (e.g. 0.91  ±  0.01 in the elbow of a patient). Four able-bodied subjects successfully positioned their arms to adequate angles by extending their elbows and a joint of the exoskeleton, with root-mean-square errors  <6°. An upper cervical SCI patient, empowered by the exoskeleton, successfully carried a ball to a goal in all 10 trials. Significance. A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.

  13. A hybrid BMI-based exoskeleton for paresis: EMG control for assisting arm movements.

    PubMed

    Kawase, Toshihiro; Sakurada, Takeshi; Koike, Yasuharu; Kansaku, Kenji

    2017-02-01

    Brain-machine interface (BMI) technologies have succeeded in controlling robotic exoskeletons, enabling some paralyzed people to control their own arms and hands. We have developed an exoskeleton asynchronously controlled by EEG signals. In this study, to enable real-time control of the exoskeleton for paresis, we developed a hybrid system with EEG and EMG signals, and the EMG signals were used to estimate its joint angles. Eleven able-bodied subjects and two patients with upper cervical spinal cord injuries (SCIs) performed hand and arm movements, and the angles of the metacarpophalangeal (MP) joint of the index finger, wrist, and elbow were estimated from EMG signals using a formula that we derived to calculate joint angles from EMG signals, based on a musculoskeletal model. The formula was exploited to control the elbow of the exoskeleton after automatic adjustments. Four able-bodied subjects and a patient with upper cervical SCI wore an exoskeleton controlled using EMG signals and were required to perform hand and arm movements to carry and release a ball. Estimated angles of the MP joints of index fingers, wrists, and elbows were correlated well with the measured angles in 11 able-bodied subjects (correlation coefficients were 0.81  ±  0.09, 0.85  ±  0.09, and 0.76  ±  0.13, respectively) and the patients (e.g. 0.91  ±  0.01 in the elbow of a patient). Four able-bodied subjects successfully positioned their arms to adequate angles by extending their elbows and a joint of the exoskeleton, with root-mean-square errors  <6°. An upper cervical SCI patient, empowered by the exoskeleton, successfully carried a ball to a goal in all 10 trials. A BMI-based exoskeleton for paralyzed arms and hands using real-time control was realized by designing a new method to estimate joint angles based on EMG signals, and these may be useful for practical rehabilitation and the support of daily actions.

  14. Comparison of neuromuscular abnormalities between upper and lower extremities in hemiparetic stroke.

    PubMed

    Mirbagheri, M M; AliBiglou, L; Thajchayapong, M; Lilaonitkul, T; Rymer, W Z

    2006-01-01

    We studied the neuromuscular mechanical properties of the elbow and ankle joints in chronic, hemiparetic stroke patients and healthy subjects. System identification techniques were used to characterize the mechanical abnormalities of these joints and to identify the contribution of intrinsic and reflex stiffness to these abnormalities. Modulation of intrinsic and reflex stiffness with the joint angle was studied by applying PRBS perturbations to the joint at different joint angles. The experiments were performed for both spastic (stroke) and contralateral (control) sides of stroke patients and one side of healthy (normal) subjects. We found reflex stiffness gain (GR) was significantly larger in the stroke than the control side for both elbow and ankle joints. GR was also strongly position dependent in both joints. However, the modulation of GR with position was slightly different in two joints. GR was also larger in the control than the normal joints but the differences were significant only for the ankle joint. Intrinsic stiffness gain (K) was also significantly larger in the stroke than the control joint at elbow extended positions and at ankle dorsiflexed positions. Modulation of K with the ankle angle was similar for stroke, control and normal groups. In contrast, the position dependency of the elbow was different. K was larger in the control than normal ankle whereas it was lower in the control than normal elbow. However, the differences were not significant for any joint. The findings demonstrate that both reflex and intrinsic stiffness gain increase abnormally in both upper and lower extremities. However, the major contribution of intrinsic and reflex stiffness to the abnormalities is at the end of ROM and at the middle ROM, respectively. The results also demonstrate that the neuromuscular properties of the contralateral limb are not normal suggesting that it may not be used as a suitable control at least for the ankle study.

  15. Changes in pennation with joint angle and muscle torque: in vivo measurements in human brachialis muscle.

    PubMed Central

    Herbert, R D; Gandevia, S C

    1995-01-01

    1. Estimates of pennation in human muscles are usually obtained from cadavers. In this study, pennation of human brachialis was measured in vivo using sonography. Effects of static and dynamic changes in elbow angle and torque were investigated. 2. Pennation was measured in eight subjects using an 80 mm, 5 MHz, linear-array ultrasound transducer to generate sagittal images of the brachialis during maximal and submaximal isometric contractions at various elbow angles. It was shown that estimates of pennation were reproducible, representative of measurements made throughout the belly of the muscle and not distorted by compression of the muscle with the transducer or rotation of the muscle out of the plane of the transducer. 3. Mean resting pennation was 9.0 +/- 2.0 deg (S.D., range 6.5-12.9 deg). When the muscle was relaxed there was no effect of elbow angle on pennation. However, during a maximal isometric contraction (MVC), with the elbow flexed to 90 deg, pennation increased non-linearly with elbow torque to between 22 and 30 deg (mean 24.7 +/- 2.4 deg). The effect of increasing torque was small when the elbow was fully extended. The relationship between elbow angle, elbow torque and brachialis pennation suggests that the relaxed brachialis muscle is slack over much of its physiological range of lengths. 4. There was no hysteresis in the relationship between torque and pennation during slow isometric contractions (0.2 MVC s-1), and the relationship between elbow angle and pennation was similar during slow shortening and lengthening contractions. 5. Two consequences follow from these findings. Firstly, intramuscular mechanics are complex and simple planar models of muscles underestimate the increases in pennation which occur during muscle contraction. Second, spindle afferents from relaxed muscles may not encode joint angle over the full range of movement. Images Figure 2 PMID:7602542

  16. Biomechanical influence of pin placement and elbow angle on joint distraction and hinge alignment for an arthrodiatasis elbow-pin-fixator construct.

    PubMed

    Lee, Wei-Shiun; Linz, Shang-Chih; Shih, Kao-Shang; Chao, Ching-Kong; Chen, Yeung-Jen; Fan, Chang-Yuan

    2012-10-01

    Stiffness and contracture of the periarticular tissues are common complications of a post-traumatic elbow. Arthrodiatasis is a surgical technique that uses an external fixator for initial immobilization and subsequent distraction. The two prerequisites for an ideal arthrodiatasis are concentric distraction (avoiding bony contact) and hinge alignment (reducing internal stress). This study used the finite element (FE) method to clarify the relationship between these two prerequisites and the initial conditions (pin placement, elbow angle, and distraction mode). A total of 12 variations of the initial conditions were symmetrically arranged to evaluate their biomechanical influence on concentric distraction and hinge alignment. The humeroulnar surface was hypothesized to be ideally distracted orthogonal to the line joining the tips of the olecranon and the coronoid. The eccentric separation of the humeroulnar surfaces is a response to the non-orthogonality of the distracting force and joining line. Pin placement significantly affects the effective moment arm of the fixing pins to distract the bridged elbow. Both elbow angle and distraction mode directly alter the direction of the distracting force at the elbow center. In general, the hinges misalignment occurs in a direction opposite to the distraction-activated site. After joint distraction, the elastic deflection of the fixing pins inevitably makes both elbow and fixator hinges to misalign. This indicates that both joint distraction and hinge alignment are the interactive mechanisms. The humeroulnar separation is more concentric in the situation of the 120 degrees humeral distraction by using stiffer pins with convergent placement. Even so, the eccentric displacement of the elbow hinge is a crucial consideration in the initial placement of the guiding pin to compensate for hinge misalignment.

  17. Development and evaluation of a musculoskeletal model of the elbow joint complex

    NASA Technical Reports Server (NTRS)

    Gonzalez, Roger V.; Hutchins, E. L.; Barr, Ronald E.; Abraham, Lawrence D.

    1993-01-01

    This paper describes the development and evaluation of a musculoskeletal model that represents human elbow flexion-extension and forearm pronation-supination. The length, velocity, and moment arm for each of the eight musculotendon actuators were based on skeletal anatomy and position. Musculotendon parameters were determined for each actuator and verified by comparing analytical torque-angle curves with experimental joint torque data. The parameters and skeletal geometry were also utilized in the musculoskeletal model for the analysis of ballistic elbow joint complex movements. The key objective was to develop a computational model, guided by parameterized optimal control, to investigate the relationship among patterns of muscle excitation, individual muscle forces, and movement kinematics. The model was verified using experimental kinematic, torque, and electromyographic data from volunteer subjects performing ballistic elbow joint complex movements.

  18. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    PubMed

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  19. Muscle contributions to elbow joint rotational stiffness in preparation for sudden external arm perturbations.

    PubMed

    Holmes, Michael W R; Keir, Peter J

    2014-04-01

    Understanding joint stiffness and stability is beneficial for assessing injury risk. The purpose of this study was to examine joint rotational stiffness for individual muscles contributing to elbow joint stability. Fifteen male participants maintained combinations of three body orientations (standing, supine, sitting) and three hand preloads (no load, solid tube, fluid filled tube) while a device imposed a sudden elbow extension. Elbow angle and activity from nine muscles were inputs to a biomechanical model to determine relative contributions to elbow joint rotational stiffness, reported as percent of total stiffness. A body orientation by preload interaction was evident for most muscles (P<.001). Brachioradialis had the largest change in contribution while standing (no load, 18.5%; solid, 23.8%; fluid, 26.3%). Across trials, the greatest contributions were brachialis (30.4±1.9%) and brachioradialis (21.7±2.2%). Contributions from the forearm muscles and triceps were 5.5±0.6% and 9.2±1.9%, respectively. Contributions increased at time points closer to the perturbation (baseline to anticipatory), indicating increased neuromuscular response to resist rotation. This study quantified muscle contributions that resist elbow perturbations, found that forearm muscles contribute marginally and showed that orientation and preload should be considered when evaluating elbow joint stiffness and safety.

  20. Joint kinematics of surgeons during lumbar pedicle screw placement.

    PubMed

    Park, Jeong-Yoon; Kim, Kyung-Hyun; Kuh, Sung-Uk; Chin, Dong-Kyu; Kim, Keun-Su; Cho, Yong-Eun

    2016-12-01

    A surgical robot for spine surgery has recently been developed. The objective is to assess the joint kinematics of the surgeon during spine surgery. We enrolled 18 spine surgeons, who each performed pedicle screw placement, and used an optoelectronic motion analysis system. Using three-dimensional (3D) motion images, distance changes in five joints and angle changes in six joints were calculated during surgery. Distance fluctuations increased gradually from the proximal to the distal joint. Angle fluctuations were largest at the distal point but did not gradually increase, and the elbow showed the second largest fluctuation. Changes along the X axis were larger than those of the Y and Z axes. The distances gradually increased from proximal portions of the body to the hand. In angle changes, the elbow was most dynamic during pedicle screw placement. The surgeons' whole joints carry out a harmonic role during lumbar pedicle screw placement. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  1. A method to determine the orientation of the upper arm about its longitudinal axis during dynamic motions.

    PubMed

    Gordon, Brian J; Dapena, Jesús

    2013-01-04

    Inaccuracy in determining the orientation of the upper arm about its longitudinal axis (twist orientation) has been a pervasive problem in sport biomechanics research. The purpose of this study was to develop a method to improve the calculation of the upper arm twist orientation in dynamic sports activities. The twist orientation of the upper arm is defined by the orientation of its mediolateral axis. The basis for the new method is that at any angle in the flexion/extension range of an individual's elbow, it is possible to define a true mediolateral axis and also a surrogate mediolateral axis perpendicular to the plane containing the shoulder, elbow and wrist joints. The difference between the twist orientations indicated by these two versions of the mediolateral axis will vary from one elbow angle to another, but if the elbow joint deforms equally in different activities, for any given subject the difference should be constant at any given value of the elbow angle. Application of the new method required individuals to execute sedate elbow extension trials prior to the dynamic trials. Three-dimensional motion analysis of the sedate extension trials allowed quantification of the difference between the true and surrogate mediolateral axes for all angles in the entire flexion/extension range of an individual's elbow. This made it possible to calculate in any dynamic trial the twist orientation defined by the true mediolateral axis from the twist orientation defined by the surrogate mediolateral axis. The method was tested on a wooden model of the arm. Copyright © 2012 Elsevier Ltd. All rights reserved.

  2. In vivo determination of the direction of rotation and moment-angle relationship of individual elbow muscles.

    PubMed

    Zhang, L; Butler, J; Nishida, T; Nuber, G; Huang, H; Rymer, W Z

    1998-10-01

    The direction of rotation (DOR) of individual elbow muscles, defined as the direction in which a muscle rotates the forearm relative to the upper arm in three-dimensional space, was studied in vivo as a function of elbow flexion and forearm rotation. Electrical stimulation was used to activate an individual muscle selectively, and the resultant flexion-extension, supination-pronation, and varus-valgus moments were used to determine the DOR. Furthermore, multi-axis moment-angle relationships of individual muscles were determined by stimulating the muscle at a constant submaximal level across different joint positions, which was assumed to result in a constant level of muscle activation. The muscles generate significant moments about axes other than flexion-extension, which is potentially important for actively controlling joint movement and maintaining stability about all axes. Both the muscle DOR and the multi axis moments vary with the joint position systematically. Variations of the DOR and moment-angle relationship across muscle twitches of different amplitudes in a subject were small, while there were considerable variations between subjects.

  3. Topsy-turvy locomotion: biomechanical specializations of the elbow in suspended quadrupeds reflect inverted gravitational constraints

    PubMed Central

    Fujiwara, Shin-ichi; Endo, Hideki; Hutchinson, John R

    2011-01-01

    Some tetrapods hang upside down from tree branches when moving horizontally. The ability to walk in quadrupedal suspension has been acquired independently in at least 14 mammalian lineages. During the stance (supportive) phase of quadrupedal suspension, the elbow joint flexor muscles (not the extensors as in upright vertebrates moving overground) are expected to contract to maintain the flexed limb posture. Therefore muscular control in inverted, suspended quadrupeds may require changes of muscle control, and even morphologies, to conditions opposite to those in upright animals. However, the relationships between musculoskeletal morphologies and elbow joint postures during the stance phase in suspended quadrupeds have not been investigated. Our analysis comparing postures and skeletal morphologies in Choloepus (Pilosa), Pteropus (Chiroptera), Nycticebus (Primates) and Cynocephalus (Dermoptera) revealed that the elbow joints of these animals were kept at flexed angles of 70–100 ° during the stance phase of quadrupedal suspension. At these joint angles the moment arms of the elbow joint flexors were roughly maximized, optimizing that component of antigravity support. Our additional measurements from various mammalian species show that suspended quadrupeds have relatively small extensor/flexor ratios in both muscle masses and maximum moment arms. Thus, in contrast to the pattern in normal terrestrial quadrupeds, suspended quadrupeds emphasize flexor over extensor muscles for body support. This condition has evolved independently multiple times, attendant with a loss or reduction of the ability to move in normal upright postures. PMID:21477151

  4. Effect of muscle length on strength and dexterity after stroke.

    PubMed

    Ada, L; Canning, C; Dwyer, T

    2000-02-01

    The effect of muscle length on strength and dexterity after stroke was investigated. The aim was to determine if poor function at a particular muscle length could be attributed solely to differential weakness at this joint angle or whether an additional problem of differential dexterity exists. This descriptive research study measured elbow flexor and extensor strength as well as dexterity at three elbow joint angles: 30 degrees , 60 degrees and 90 degrees flexion. Dexterity was measured independently of strength. Fifteen (seven female, eight male) chronic stroke patients (mean age 67 years) who could actively flex and extend their affected elbow participated. Ten neurologically normal control subjects (mean age 67 years) acted as controls. Strength was measured as peak elbow flexor and extensor torque at three angles; and dexterity was measured as coherence for slow and fast tracking also at three angles. Dexterity was not affected by muscle length but strength was and this finding was the same for both stroke and controls. While the magnitude of the torque-angle curves was not significantly different between stroke and controls, the shape of torque-angle curves was altered after stroke so that both the elbow flexors (p < 0.05) and extensors (p < 0.05) tested weaker in the testing position where they were shortest. Since there was no differential loss of dexterity, it appears that differential loss of strength, especially in the shortened range, may explain the clinical observation of poorer function at one muscle length than another after stroke. Specific training to strengthen the muscles in these ranges is therefore of clinical importance for rehabilitation.

  5. Isometric torque-angle relationship and movement-related activity of human elbow flexors: implications for the equilibrium-point hypothesis.

    PubMed

    Hasan, Z; Enoka, R M

    1985-01-01

    Since the moment arms for the elbow-flexor muscles are longest at intermediate positions of the elbow and shorter at the extremes of the range of motion, it was expected that the elbow torque would also show a peak at an intermediate angle provided the activity of the flexor muscles remained constant. We measured the isometric elbow torque at different elbow angles while the subject attempted to keep constant the electromyographic activity (EMG) of the brachioradialis muscle. The torque-angle relationship thus obtained exhibited a peak, as expected, but the shape of the relationship varied widely among subjects. This was due in part to differences in the variation of the biceps brachii EMG with elbow angle among the different subjects. The implications of these observations for the equilibrium-point hypothesis of movement were investigated as follows. The subject performed elbow movements in the presence of an external torque (which tended to extend the elbow joint) provided by a weight-and-pulley arrangement. We found in the case of flexion movements that invariably there was a transient increase in flexor EMG, as would seem necessary for initiating the movement. However, the steady-state EMG after the movement could be greater or less than the pre-movement EMG. Specifically, the least flexor EMG was required for equilibrium in the intermediate range of elbow angles, compared to the extremes of the range of motion. The EMG-angle relationship, however, varied with the muscle and the subject. The observation that the directions of change in the transient and the steady-state EMG are independent of each other militates against the generality of the equilibrium-point hypothesis. However, a form of the hypothesis which includes the effects of the stretch reflex is not contradicted by this observation.

  6. Stability test of the silicon Fiber Bragg Grating embroidered on textile for joint angle measurement

    NASA Astrophysics Data System (ADS)

    Apiwattanadej, Thanit; Chun, Byung Jae; Lee, Hyub; Li, King Ho Holden; Kim, Young-Jin

    2017-06-01

    Recently, Fiber Bragg Grating (FBG) sensors are being used for motion tracking applications. However, the sensitivity, linearity and stability of the systems have not been fully studied. Herein, an embroidered optical Fiber Bragg Grating (FBG) on a stretchable supportive textile for elbow movement measurement was developed. The sensing principle of this system is based on the alteration of Bragg wavelength due to strain from the elbow movements. The relationship between elbow movements and reflected Bragg wavelength was found to be linear. The dynamic range of FBG sensor on elbow support is between 0 and 120 degree. Finally, the stability of the FBG sensor on the supportive textile was tested during the exercise and the cleaning process with water. The sensitivity of FBG sensors for joint angle measurement and the effect of the movement and cleaning process to signals from FBG sensors after using in the real activity will be the basis knowledge for design and actual implementation of future optical fiber based wearable devices.

  7. Elbow and knee joint for hard space suits

    NASA Technical Reports Server (NTRS)

    Vykukal, H. C.

    1986-01-01

    An elbow or knee joint for a hard space suit or similar usage is formed of three serially connected rigid sections which have truncated spherical configurations. The ends of each section form solid geometric angles, and the sections are interconnected by hermetically sealed ball bearings. The outer two sections are fixed together for rotation in a direction opposite to rotation of the center section. A preferred means to make the outer sections track each other in rotation comprises a rotatable continuous bead chain which engages sockets circumferentially spaced on the facing sides of the outer races of the bearings. The joint has a single pivot point and the bearing axes are always contained in a single plane for any articulation of the joint. Thus flexure of the joint simulates the coplanar flexure of the knee or elbow and is not susceptible to lockup.

  8. Neuromuscular properties of different spastic human joints vary systematically.

    PubMed

    Mirbagheri, M M; Settle, K

    2010-01-01

    We quantified the mechanical abnormalities of the spastic wrist in chronic stroke survivors, and determined whether these findings were representative of those recorded at the elbow and ankle joints. System identification techniques were used to characterize the mechanical abnormalities of these joints and to identify the contribution of intrinsic and reflex stiffness to these abnormalities. Modulation of intrinsic and reflex stiffness with the joint angle was studied by applying PRBS perturbations to the joints at different joint angles over the range of motion. Age-matched healthy subjects were used as control.

  9. Elbow joint position sense after neuromuscular training with handheld vibration.

    PubMed

    Tripp, Brady L; Faust, Donald; Jacobs, Patrick

    2009-01-01

    Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Crossover study. University athletic training research laboratory. Thirty-one healthy, college-aged volunteers (16 men, 15 women, age = 23 + or - 3 years, height = 173 + or - 8 cm, mass = 76 + or - 14 kg). We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90 degrees ) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P < or = .005), whereas 5-Hz vibration did not affect accuracy (F(1,61) = 2.625, P = .100) but did decrease variability (F(1,61) = 7.250, P = .009). The control condition and 0-Hz training protocol had no effect on accuracy or variability (P > or = .200). Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury.

  10. Reliability and validity of the Microsoft Kinect for assessment of manual wheelchair propulsion.

    PubMed

    Milgrom, Rachel; Foreman, Matthew; Standeven, John; Engsberg, Jack R; Morgan, Kerri A

    2016-01-01

    Concurrent validity and test-retest reliability of the Microsoft Kinect in quantification of manual wheelchair propulsion were examined. Data were collected from five manual wheelchair users on a roller system. Three Kinect sensors were used to assess test-retest reliability with a still pose. Three systems were used to assess concurrent validity of the Kinect to measure propulsion kinematics (joint angles, push loop characteristics): Kinect, Motion Analysis, and Dartfish ProSuite (Dartfish joint angles were limited to shoulder and elbow flexion). Intraclass correlation coefficients revealed good reliability (0.87-0.99) between five of the six joint angles (neck flexion, shoulder flexion, shoulder abduction, elbow flexion, wrist flexion). ICCs suggested good concurrent validity for elbow flexion between the Kinect and Dartfish and between the Kinect and Motion Analysis. Good concurrent validity was revealed for maximum height, hand-axle relationship, and maximum area (0.92-0.95) between the Kinect and Dartfish and maximum height and hand-axle relationship (0.89-0.96) between the Kinect and Motion Analysis. Analysis of variance revealed significant differences (p < 0.05) in maximum length between Dartfish (mean 58.76 cm) and the Kinect (40.16 cm). Results pose promising research and clinical implications for propulsion assessment and overuse injury prevention with the application of current findings to future technology.

  11. Simultaneous and Continuous Estimation of Shoulder and Elbow Kinematics from Surface EMG Signals

    PubMed Central

    Zhang, Qin; Liu, Runfeng; Chen, Wenbin; Xiong, Caihua

    2017-01-01

    In this paper, we present a simultaneous and continuous kinematics estimation method for multiple DoFs across shoulder and elbow joint. Although simultaneous and continuous kinematics estimation from surface electromyography (EMG) is a feasible way to achieve natural and intuitive human-machine interaction, few works investigated multi-DoF estimation across the significant joints of upper limb, shoulder and elbow joints. This paper evaluates the feasibility to estimate 4-DoF kinematics at shoulder and elbow during coordinated arm movements. Considering the potential applications of this method in exoskeleton, prosthetics and other arm rehabilitation techniques, the estimation performance is presented with different muscle activity decomposition and learning strategies. Principle component analysis (PCA) and independent component analysis (ICA) are respectively employed for EMG mode decomposition with artificial neural network (ANN) for learning the electromechanical association. Four joint angles across shoulder and elbow are simultaneously and continuously estimated from EMG in four coordinated arm movements. By using ICA (PCA) and single ANN, the average estimation accuracy 91.12% (90.23%) is obtained in 70-s intra-cross validation and 87.00% (86.30%) is obtained in 2-min inter-cross validation. This result suggests it is feasible and effective to use ICA (PCA) with single ANN for multi-joint kinematics estimation in variant application conditions. PMID:28611573

  12. Changes in head and neck position have a greater effect on elbow joint position sense in people with whiplash-associated disorders.

    PubMed

    Knox, Joanna Joy; Beilstein, Darren Jay; Charles, Scott Darren; Aarseth, Geir Arne; Rayar, Shivanthi; Treleaven, Julia; Hodges, Paul William

    2006-01-01

    It has been shown that perception of elbow joint position is affected by changes in head and neck position. Further, people with whiplash-associated disorders (WAD) present with deficits in upper limb coordination and movement. This study is aimed to determine whether the effect of changes in head position on elbow joint position error (JPE) is more pronounced in people with WAD, and to determine whether this is related to the participant's pain and anxiety levels. Nine people with chronic and disabling WAD and 11 healthy people participated in this experiment. The ability to reproduce a position at the elbow joint was assessed after changes in the position of the head and neck to 30 degrees , and with the head in the midline. Pain was monitored in WAD participants. Absolute elbow JPE with the head in neutral was not different between WAD and control participants (P=0.5). Changes in the head and neck position increased absolute elbow JPE in the WAD group (P<0.05), but did not affect elbow JPE in the control group (P=0.4). There was a connection between pain during testing and the effect of changes in head position on elbow JPE (P<0.05). Elbow JPE is affected by movement of the head and neck, with smaller angles of neck rotation in people with WAD than in healthy individuals. This observation may explain deficits in upper limb coordination in people with WAD, which may be due to the presence of pain or reduced range of motion in this population.

  13. Articular Contact Area and Pressure in Posteromedial Rotatory Instability of the Elbow.

    PubMed

    Bellato, Enrico; Fitzsimmons, James S; Kim, Youngbok; Bachman, Daniel R; Berglund, Lawrence J; Hooke, Alexander W; O'Driscoll, Shawn W

    2018-03-21

    Joint incongruity in posteromedial rotatory instability (PMRI) has been theorized to determine early articular degenerative changes. Our hypothesis was that the articular contact area and contact pressure differ significantly between an intact elbow and an elbow affected by PMRI. Seven cadaveric elbows were tested under gravity varus stress using a custom-made machine designed to simulate muscle loads and allow passive elbow flexion (0° to 90°). The mean contact area and contact pressure data were collected and processed using the Tekscan sensor and software. After testing the intact specimen (intact elbow), a PMRI injury was simulated (PMRI elbow) and the specimen was tested again. The PMRI elbows were characterized by initial joint subluxation and significantly elevated articular contact pressure. Both worsened, corresponding with a reduction in contact area, as the elbow was flexed from 0° until the joint subluxation and incongruity spontaneously reduced (at a mean [and standard error] of 60° ± 5° of flexion), at which point the mean contact pressure decreased from 870 ± 50 kPa (pre-reduction) to 440 ± 40 kPa (post-reduction) (p < 0.001) and the mean contact area increased from 80 ± 8 mm to 150 ± 58 mm (p < 0.001). This reduction of the subluxation was also followed by a shift of the contact area from the coronoid fracture edge toward the lower portion of the coronoid. At the flexion angle at which the PMRI elbows reduced, both the contact area and the contact pressure of the intact elbows differed significantly from those of the PMRI elbows, both before and after the elbow reduction (p < 0.001). The reduction in contact area and increased contact pressures due to joint subluxation and incongruity could explain the progressive arthritis seen in some elbows affected by PMRI. This biomechanical study suggests that the early degenerative changes associated with PMRI reported in the literature could be subsequent to joint incongruity and an increase in contact pressure between the coronoid fracture surface and the trochlea.

  14. Design and characterization of a wearable macrobending fiber optic sensor for human joint angle determination

    NASA Astrophysics Data System (ADS)

    Silva, Ana S.; Catarino, André; Correia, Miguel V.; Frazão, Orlando

    2013-12-01

    The work presented here describes the development and characterization of intensity fiber optic sensor integrated in a specifically designed piece of garment to measure elbow flexion. The sensing head is based on macrobending incorporated in the garment, and the increase of curvature number was studied in order to investigate which scheme provided a good result in terms of sensitivity and repeatability. Results showed the configuration that assured a higher sensitivity (0.644 dBm/deg) and better repeatability was the one with four loops. Ultimately, this sensor can be used for rehabilitation purposes to monitor human joint angles, namely, elbow flexion on stroke survivors while performing the reach functional task, which is the most common upper-limb human gesture.

  15. Kinematic analysis of upper extremity movement during drinking in hemiplegic subjects.

    PubMed

    Kim, Kyung; Song, Won-Kyung; Lee, Jeongsu; Lee, Hwi-Young; Park, Dae Sung; Ko, Byung-Woo; Kim, Jongbae

    2014-03-01

    It is necessary to analyze the kinematic properties of a paralyzed extremity to quantitatively determine the degree of impairment of hemiplegic people during functional activities of daily living (ADL) such as a drinking task. This study aimed to identify the kinematic differences between 16 hemiplegic and 32 able-bodied participants in relation to the task phases when drinking with a cup and the kinematic strategy used during motion with respect to the gravity direction. The subjects performed a drinking task that was divided into five phases according to Murphy's phase definition: reaching, forward transport, drinking, backward transport, and returning. We found that the groups differed in terms of the movement times and the joint angles and angular velocities of the shoulder, elbow, and wrist joints. Compared to the control group, the hemiplegic participants had a larger shoulder abduction angle of at most 17.1° during all the phases, a larger shoulder flexion angle of 7.6° during the reaching phase, and a smaller shoulder flexion angle of 6.4° during the backward transporting phase. Because of these shoulder joint patterns, a smaller elbow pronation peak angle of at most 13.1° and a larger wrist extension peak angle of 12.0° were found in the motions of the hemiplegic participants, as compensation to complete the drinking task. The movement in the gravity direction during the backward transporting phase resulted in a 15.9% larger peak angular velocity for elbow extension in the hemiplegic participants compared to that of the control group. These quantitative kinematic patterns help provide an understanding of the movements of an affected extremity and can be useful in designing rehabilitation robots to assist hemiplegic people with ADL. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Movement-related and steady-state electromyographic activity of human elbow flexors in slow transition movements between two equilibrium states.

    PubMed

    Tal'nov, A N; Cherkassky, V L; Kostyukov, A I

    1997-08-01

    The electromyograms were recorded in healthy human subjects by surface electrodes from the mm. biceps brachii (caput longum et. brevis), brachioradialis, and triceps brachii (caput longum) during slow transition movements in elbow joint against a weak extending torque. The test movements (flexion transitions between two steady-states) were fulfilled under visual control through combining on a monitor screen a signal from a joint angle sensor with a corresponding command generated by a computer. Movement velocities ranged between 5 and 80 degrees/s, subjects were asked to move forearm without activation of elbow extensors. Surface electromyograms were full-wave rectified, filtered and averaged within sets of 10 identical tests. Amplitudes of dynamic and steady-state components of the electromyograms were determined in dependence on a final value of joint angle, slow and fast movements were compared. An exponential-like increase of dynamic component was observed in electromyograms recorded from m. biceps brachii, the component had been increased with movement velocity and with load increment. In many experiments a statistically significant decrease of static component could be noticed within middle range of joint angles (40-60 degrees) followed by a well expressed increment for larger movements. This pattern of the static component in electromyograms could vary in different experiments even in the same subjects. A steady discharge in m. brachioradialis at ramp phase has usually been recorded only under a notable load. Variable and quite often unpredictable character of the static components of the electromyograms recorded from elbow flexors in the transition movements makes it difficult to use the equilibrium point hypothesis to describe the central processes of movement. It has been assumed that during active muscle shortening the dynamic components in arriving efferent activity should play a predominant role. A simple scheme could be proposed for transition to a steady-state after shortening. Decrease of the efferent inflow can evoke internal lengthening of the contractile elements in muscle and, as a result, hysteresis increase in the muscle contraction efficiency. Effectiveness in maintenance of the steady position seems to also be enhanced due to muscle thixotropy and friction processes in the joint. Hysteresis after-effects in elbow flexors were demonstrated as a difference in steady-state levels of electromyograms with oppositely directed approaches to the same joint position.

  17. Rubber Hand Illusion Affects Joint Angle Perception

    PubMed Central

    Butz, Martin V.; Kutter, Esther F.; Lorenz, Corinna

    2014-01-01

    The Rubber Hand Illusion (RHI) is a well-established experimental paradigm. It has been shown that the RHI can affect hand location estimates, arm and hand motion towards goals, the subjective visual appearance of the own hand, and the feeling of body ownership. Several studies also indicate that the peri-hand space is partially remapped around the rubber hand. Nonetheless, the question remains if and to what extent the RHI can affect the perception of other body parts. In this study we ask if the RHI can alter the perception of the elbow joint. Participants had to adjust an angular representation on a screen according to their proprioceptive perception of their own elbow joint angle. The results show that the RHI does indeed alter the elbow joint estimation, increasing the agreement with the position and orientation of the artificial hand. Thus, the results show that the brain does not only adjust the perception of the hand in body-relative space, but it also modifies the perception of other body parts. In conclusion, we propose that the brain continuously strives to maintain a consistent internal body image and that this image can be influenced by the available sensory information sources, which are mediated and mapped onto each other by means of a postural, kinematic body model. PMID:24671172

  18. Investigating locomotion of dairy cows by use of high speed cinematography.

    PubMed

    Herlin, A H; Drevemo, S

    1997-05-01

    The longterm influence of management systems on the locomotion of 17 dairy cows was investigated by high speed cinematography (100 frames/s) and kinematic analysis. Angular patterns and hoof trajectories of the left fore- and hindlimbs are presented and statistics made of occurring minimum and maximum angles. At the recording, 3 cows had been kept in tie-stalls (TI) and 6 cows in cubicles (CI) for a consecutive time of about 2.5 years while 8 cows had been kept on grass for about 3 months. Four of the grazing cows had earlier been kept in cubicles (CG) and 4 in tie-stalls (TG) during earlier off grazing seasons together with TI and CI cows. The CI cows had a smaller maximum angle of the elbow joint compared to TI, TG and CG cows. The hock joint angle of the CI cows was less flexed during the stance phase than in TI and CG cows while the minimum angle during the swing phase was greater in the TI and CI cows compared to TG and CG cows. Pastured cows (TG and CG) had a less pronounced flexion of the fetlock joint angle during the stance compared to cows kept indoors (TI and CI). The results suggest that slatted floor and lack of exercise during summer grazing may affect locomotion. This is indicated by restrictions in the movements of the elbow and hock joints and in less fetlock joint flexion at full support.

  19. Inverse Kinematics for Upper Limb Compound Movement Estimation in Exoskeleton-Assisted Rehabilitation.

    PubMed

    Cortés, Camilo; de Los Reyes-Guzmán, Ana; Scorza, Davide; Bertelsen, Álvaro; Carrasco, Eduardo; Gil-Agudo, Ángel; Ruiz-Salguero, Oscar; Flórez, Julián

    2016-01-01

    Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury). The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement. The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton. This approximation is rough since their kinematic structures differ. Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup. Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains. EIKPE has been tested with single DOF movements of the wrist and elbow joints. This paper presents the assessment of EIKPE with elbow-shoulder compound movements (i.e., object prehension). Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage). The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compound movement execution, especially for the shoulder joint angles. This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types.

  20. Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

    PubMed Central

    Merad, Manelle; de Montalivet, Étienne; Touillet, Amélie; Martinet, Noël; Roby-Brami, Agnès; Jarrassé, Nathanaël

    2018-01-01

    Most transhumeral amputees report that their prosthetic device lacks functionality, citing the control strategy as a major limitation. Indeed, they are required to control several degrees of freedom with muscle groups primarily used for elbow actuation. As a result, most of them choose to have a one-degree-of-freedom myoelectric hand for grasping objects, a myoelectric wrist for pronation/supination, and a body-powered elbow. Unlike healthy upper limb movements, the prosthetic elbow joint angle, adjusted prior to the motion, is not involved in the overall upper limb movements, causing the rest of the body to compensate for the lack of mobility of the prosthesis. A promising solution to improve upper limb prosthesis control exploits the residual limb mobility: like in healthy movements, shoulder and prosthetic elbow motions are coupled using inter-joint coordination models. The present study aims to test this approach. A transhumeral amputated individual used a prosthesis with a residual limb motion-driven elbow to point at targets. The prosthetic elbow motion was derived from IMU-based shoulder measurements and a generic model of inter-joint coordinations built from healthy individuals data. For comparison, the participant also performed the task while the prosthetic elbow was implemented with his own myoelectric control strategy. The results show that although the transhumeral amputated participant achieved the pointing task with a better precision when the elbow was myoelectrically-controlled, he had to develop large compensatory trunk movements. Automatic elbow control reduced trunk displacements, and enabled a more natural body behavior with synchronous shoulder and elbow motions. However, due to socket impairments, the residual limb amplitudes were not as large as those of healthy shoulder movements. Therefore, this work also investigates if a control strategy whereby prosthetic joints are automatized according to healthy individuals' coordination models can lead to an intuitive and natural prosthetic control. PMID:29456499

  1. Elbow Joint Position Sense After Neuromuscular Training With Handheld Vibration

    PubMed Central

    Tripp, Brady L.; Faust, Donald; Jacobs, Patrick

    2009-01-01

    Abstract Context: Clinicians use neuromuscular control exercises to enhance joint position sense (JPS); however, because standardizing such exercises is difficult, validations of their use are limited. Objective: To evaluate the acute effects of a neuromuscular training exercise with a handheld vibrating dumbbell on elbow JPS acuity. Design: Crossover study. Setting: University athletic training research laboratory. Patients or Other Participants: Thirty-one healthy, college-aged volunteers (16 men, 15 women, age  =  23 ± 3 years, height  =  173 ± 8 cm, mass  =  76 ± 14 kg). Intervention(s): We measured and trained elbow JPS using an electromagnetic tracking device that provided auditory and visual biofeedback. For JPS testing, participants held a dumbbell and actively identified the target elbow flexion angle (90°) using the software-generated biofeedback, followed by 3 repositioning trials without feedback. Each neuromuscular training protocol included 3 exercises during which participants held a 2.55-kg dumbbell vibrating at 15, 5, or 0 Hz and used software-generated biofeedback to locate and maintain the target elbow flexion angle for 15 seconds. Main Outcome Measure(s): We calculated absolute (accuracy) and variable (variability) errors using the differences between target and reproduced angles. Results: Training protocols using 15-Hz vibration enhanced accuracy and decreased variability of elbow JPS (P ≤ .005), whereas 5-Hz vibration did not affect accuracy (F1,61  =  2.625, P  =  .100) but did decrease variability (F1,61  =  7.250, P  =  .009). The control condition and 0-Hz training protocol had no effect on accuracy or variability (P ≥ .200). Conclusions: Our results suggest these neuromuscular control exercises, which included low-magnitude, low-frequency handheld vibration, may enhance elbow JPS. Future researchers should examine vibration of various durations and frequencies, should include injured participants and functional multijoint and multiplanar measures, and should examine long-term effects of training protocols on JPS and injury. PMID:19911088

  2. Control of speed during the double poling technique performed by elite cross-country skiers.

    PubMed

    Lindinger, Stefan Josef; Stöggl, Thomas; Müller, Erich; Holmberg, Hans-Christer

    2009-01-01

    Double poling (DP) as a main technique in cross-country skiing has developed substantially over the last 15 yr. The purpose of the present study was to analyze the question, "How do modern elite skiers control DP speed?" Twelve male elite cross-country skiers roller skied using DP at 9, 15, 21, and 27 km.h(-1) and maximum velocity (V(max)). Cycle characteristics, pole and plantar forces, and elbow, hip, and knee joint angles were analyzed. Both poling frequency and cycle length increased up to 27 km.h (-1)(P < 0.05), with a further increase in poling frequency at V(max) (P < 0.05). Peak pole force, rate of force development, and rearfoot plantar force increased with submaximal velocities (V(sm)), whereas poling time and time-to-peak pole force gradually shortened (P < 0.05). Changes in elbow joint kinematics during the poling phase were characterized by a decreased angle minimum and an increased flexion and extension ranges of motion as well as angular velocities across V(sm) (P < 0.05), with no further changes at V(max). Hip and knee joint kinematics adapted across V(sm) by 1) decreasing angles at pole plant and angle minima during the poling phase, 2) increasing the ranges of motion and angular velocities during the flexion phases occurring around pole plant, and 3) increasing extension ranges of motion and angular velocities during the recovery phase (all P values <0.05), with no further changes at V(max). Elite skiers control DP speed by increasing both poling frequency and cycle length; the latter is achieved by increased pole force despite reduced poling time. Adaptation to higher speeds was assisted by an increased range of motion, smaller angle minima, and higher angular velocities in the elbow, the hip, and the knee joints.

  3. Sex differences in kinematic adaptations to muscle fatigue induced by repetitive upper limb movements.

    PubMed

    Bouffard, Jason; Yang, Chen; Begon, Mickael; Côté, Julie

    2018-04-19

    Muscle fatigue induced by repetitive movements contributes to the development of musculoskeletal disorders. Men and women respond differently to muscle fatigue during isometric single-joint efforts, but sex differences during dynamic multi-joint tasks have not been clearly identified. Moreover, most studies comparing men and women during fatigue development assessed endurance time. However, none evaluated sex differences in kinematic adaptations to fatigue during multi-joint dynamic tasks. The objective of the study was to compare how men and women adapt their upper body kinematics during a fatiguing repetitive pointing task. Forty men and 41 women performed repetitive pointing movements (one per second) between two targets while maintaining their elbow elevated at shoulder height. The task ended when participants rated a perceived level of fatigue of 8/10. Trunk, humerothoracic, and elbow angles were compared between the first and last 30 s of the experiment and between men and women. Linear positions of the index finger (distance from the target) and the elbow (arm elevation) as well as movement timing were documented as task performance measures. Men (7.4 ± 3.2 min) and women (8.3 ± 4.5 min) performed the repetitive pointing task for a similar duration. For both sex groups, trunk range of motion increased with fatigue while shoulder's and elbow's decreased. Moreover, participants modified their trunk posture to compensate for the decreased humerothoracic elevation. Movements at all joints also became more variable with fatigue. However, of the 24 joint angle variables assessed, only two Sex × Fatigue interactions were observed. Although average humerothoracic elevation angle decreased in both subgroups, this decrease was greater in men (standardized response mean [SRM] - 1.63) than in women (SRM - 1.44). Moreover, the movement-to-movement variability of humerothoracic elevation angle increased only in women (SRM 0.42). Despite many similarities between men's and women's response to fatigue induced by repetitive pointing movements, some sex differences were observed. Those subtle differences may indicate that men's shoulder muscles were more fatigued than women's despite a similar level of perceived exertion. They may also indicate that men and women do not adapt the exact same way to a similar fatigue.

  4. Cerebellar ataxia: abnormal control of interaction torques across multiple joints.

    PubMed

    Bastian, A J; Martin, T A; Keating, J G; Thach, W T

    1996-07-01

    1. We studied seven subjects with cerebellar lesions and seven control subjects as they made reaching movements in the sagittal plane to a target directly in front of them. Reaches were made under three different conditions: 1) "slow-accurate," 2) "fast-accurate," and 3) "fast as possible." All subjects were videotaped moving in a sagittal plane with markers on the index finger, wrist, elbow, and shoulder. Marker positions were digitized and then used to calculate joint angles. For each of the shoulder, elbow and wrist joints, inverse dynamics equations based on a three-segment limb model were used to estimate the net torque (sum of components) and each of the component torques. The component torques consisted of the torque due to gravity, the dynamic interaction torques induced passively by the movement of the adjacent joint, and the torque produced by the muscles and passive tissue elements (sometimes called "residual" torque). 2. A kinematic analysis of the movement trajectory and the change in joint angles showed that the reaches of subjects with cerebellar lesions were abnormal compared with reaches of control subjects. In both the slow-accurate and fast-accurate conditions the cerebellar subjects made abnormally curved wrist paths; the curvature was greater in the slow-accurate condition. During the slow-accurate condition, cerebellar subjects showed target undershoot and tended to move one joint at a time (decomposition). During the fast-accurate reaches, the cerebellar subjects showed target overshoot. Additionally, in the fast-accurate condition, cerebellar subjects moved the joints at abnormal rates relative to one another, but the movements were less decomposed. Only three subjects were tested in the fast as possible condition; this condition was analyzed only to determine maximal reaching speeds of subjects with cerebellar lesions. Cerebellar subjects moved more slowly than controls in all three conditions. 3. A kinetic analysis of torques generated at each joint during the slow-accurate reaches and the fast-accurate reaches revealed that subjects with cerebellar lesions produced very different torque profiles compared with control subjects. In the slow-accurate condition, the cerebellar subjects produced abnormal elbow muscle torques that prevented the normal elbow extension early in the reach. In the fast-accurate condition, the cerebellar subjects produced inappropriate levels of shoulder muscle torque and also produced elbow muscle torques that did not very appropriately with the dynamic interaction torques that occurred at the elbow. Lack of appropriate muscle torque resulted in excessive contributions of the dynamic interaction torque during the fast-accurate reaches. 4. The inability to produce muscle torques that predict, accommodate, and compensate for the dynamic interaction torques appears to be an important cause of the classic kinematic deficits shown by cerebellar subjects during attempted reaching. These kinematic deficits include incoordination of the shoulder and the elbow joints, a curved trajectory, and overshoot. In the fast-accurate condition, cerebellar subjects often made inappropriate muscle torques relative to the dynamic interaction torques. Because of this, interaction torques often determined the pattern of incoordination of the elbow and shoulder that produced the curved trajectory and target overshoot. In the slow-accurate condition, we reason that the cerebellar subjects may use a decomposition strategy so as to simplify the movement and not have to control both joints simultaneously. From these results, we suggest that a major role of the cerebellum is in generating muscle torques at a joint that will predict the interaction torques being generated by other moving joints and compensate for them as they occur.

  5. Subject-specific computer simulation model for determining elbow loading in one-handed tennis backhand groundstrokes.

    PubMed

    King, Mark A; Glynn, Jonathan A; Mitchell, Sean R

    2011-11-01

    A subject-specific angle-driven computer model of a tennis player, combined with a forward dynamics, equipment-specific computer model of tennis ball-racket impacts, was developed to determine the effect of ball-racket impacts on loading at the elbow for one-handed backhand groundstrokes. Matching subject-specific computer simulations of a typical topspin/slice one-handed backhand groundstroke performed by an elite tennis player were done with root mean square differences between performance and matching simulations of < 0.5 degrees over a 50 ms period starting from ball impact. Simulation results suggest that for similar ball-racket impact conditions, the difference in elbow loading for a topspin and slice one-handed backhand groundstroke is relatively small. In this study, the relatively small differences in elbow loading may be due to comparable angle-time histories at the wrist and elbow joints with the major kinematic differences occurring at the shoulder. Using a subject-specific angle-driven computer model combined with a forward dynamics, equipment-specific computer model of tennis ball-racket impacts allows peak internal loading, net impulse, and shock due to ball-racket impact to be calculated which would not otherwise be possible without impractical invasive techniques. This study provides a basis for further investigation of the factors that may increase elbow loading during tennis strokes.

  6. Inverse Kinematics for Upper Limb Compound Movement Estimation in Exoskeleton-Assisted Rehabilitation

    PubMed Central

    Cortés, Camilo; de los Reyes-Guzmán, Ana; Scorza, Davide; Bertelsen, Álvaro; Carrasco, Eduardo; Gil-Agudo, Ángel; Ruiz-Salguero, Oscar; Flórez, Julián

    2016-01-01

    Robot-Assisted Rehabilitation (RAR) is relevant for treating patients affected by nervous system injuries (e.g., stroke and spinal cord injury). The accurate estimation of the joint angles of the patient limbs in RAR is critical to assess the patient improvement. The economical prevalent method to estimate the patient posture in Exoskeleton-based RAR is to approximate the limb joint angles with the ones of the Exoskeleton. This approximation is rough since their kinematic structures differ. Motion capture systems (MOCAPs) can improve the estimations, at the expenses of a considerable overload of the therapy setup. Alternatively, the Extended Inverse Kinematics Posture Estimation (EIKPE) computational method models the limb and Exoskeleton as differing parallel kinematic chains. EIKPE has been tested with single DOF movements of the wrist and elbow joints. This paper presents the assessment of EIKPE with elbow-shoulder compound movements (i.e., object prehension). Ground-truth for estimation assessment is obtained from an optical MOCAP (not intended for the treatment stage). The assessment shows EIKPE rendering a good numerical approximation of the actual posture during the compound movement execution, especially for the shoulder joint angles. This work opens the horizon for clinical studies with patient groups, Exoskeleton models, and movements types. PMID:27403420

  7. Musculoskeletal loading during the round-off in female gymnastics: the effect of hand position.

    PubMed

    Farana, Roman; Jandacka, Daniel; Uchytil, Jaroslav; Zahradnik, David; Irwin, Gareth

    2014-06-01

    Chronic elbow injuries from tumbling in female gymnastics present a serious problem for performers. This research examined how the biomechanical characteristics of impact loading and elbow kinematics and kinetics change as a function of technique selection. Seven international-level female gymnasts performed 10 trials of the round-off from a hurdle step to flic-flac with 'parallel' and 'T-shape' hand positions. Synchronized kinematic (3D-automated motion analysis system; 247 Hz) and kinetic (two force plates; 1,235 Hz) data were collected for each trial. Wilcoxon non-parametric test and effect-size statistics determined differences between the hand positions examined in this study. Significant differences (p < 0.05) and large effect sizes (ES > 0.8) were observed for peak vertical ground reaction force (GRF), anterior-posterior GRF, resultant GRF, loading rates of these forces and elbow joint angles, and internal moments of force in sagittal, transverse, and frontal planes. In conclusion, the T-shape hand position reduces vertical, anterior-posterior, and resultant contact forces and has a decreased loading rate indicating a safer technique for the round-off. Significant differences observed in joint elbow moments highlighted that the T-shape position may prevent overloading of the joint complex and consequently reduce the potential for elbow injury.

  8. Reconstructing for joint angles on the shoulder and elbow from non-invasive electroencephalographic signals through electromyography

    PubMed Central

    Choi, Kyuwan

    2013-01-01

    In this study, first the cortical activities over 2240 vertexes on the brain were estimated from 64 channels electroencephalography (EEG) signals using the Hierarchical Bayesian estimation while 5 subjects did continuous arm reaching movements. From the estimated cortical activities, a sparse linear regression method selected only useful features in reconstructing the electromyography (EMG) signals and estimated the EMG signals of 9 arm muscles. Then, a modular artificial neural network was used to estimate four joint angles from the estimated EMG signals of 9 muscles: one for movement control and the other for posture control. The estimated joint angles using this method have the correlation coefficient (CC) of 0.807 (±0.10) and the normalized root-mean-square error (nRMSE) of 0.176 (±0.29) with the actual joint angles. PMID:24167469

  9. Upper Limb Posture Estimation in Robotic and Virtual Reality-Based Rehabilitation

    PubMed Central

    Cortés, Camilo; Ardanza, Aitor; Molina-Rueda, F.; Cuesta-Gómez, A.; Ruiz, Oscar E.

    2014-01-01

    New motor rehabilitation therapies include virtual reality (VR) and robotic technologies. In limb rehabilitation, limb posture is required to (1) provide a limb realistic representation in VR games and (2) assess the patient improvement. When exoskeleton devices are used in the therapy, the measurements of their joint angles cannot be directly used to represent the posture of the patient limb, since the human and exoskeleton kinematic models differ. In response to this shortcoming, we propose a method to estimate the posture of the human limb attached to the exoskeleton. We use the exoskeleton joint angles measurements and the constraints of the exoskeleton on the limb to estimate the human limb joints angles. This paper presents (a) the mathematical formulation and solution to the problem, (b) the implementation of the proposed solution on a commercial exoskeleton system for the upper limb rehabilitation, (c) its integration into a rehabilitation VR game platform, and (d) the quantitative assessment of the method during elbow and wrist analytic training. Results show that this method properly estimates the limb posture to (i) animate avatars that represent the patient in VR games and (ii) obtain kinematic data for the patient assessment during elbow and wrist analytic rehabilitation. PMID:25110698

  10. Elbow joint variability for different hand positions of the round off in gymnastics.

    PubMed

    Farana, Roman; Irwin, Gareth; Jandacka, Daniel; Uchytil, Jaroslav; Mullineaux, David R

    2015-02-01

    The aim of the present study was to conduct within-gymnast analyses of biological movement variability in impact forces, elbow joint kinematics and kinetics of expert gymnasts in the execution of the round-off with different hand positions. Six international level female gymnasts performed 10 trials of the round-off from a hurdle step to a back-handspring using two hand potions: parallel and T-shape. Two force plates were used to determine ground reaction forces. Eight infrared cameras were employed to collect the kinematic data automatically. Within gymnast variability was calculated using biological coefficient of variation (BCV) discretely for ground reaction force, kinematic and kinetic measures. Variability of the continuous data was quantified using coefficient of multiple correlations (CMC). Group BCV and CMC were calculated and T-test with effect size statistics determined differences between the variability of the two techniques examined in this study. The major observation was a higher level of biological variability in the elbow joint abduction angle and adduction moment of force in the T-shaped hand position. This finding may lead to a reduced repetitive abduction stress and thus protect the elbow joint from overload. Knowledge of the differences in biological variability can inform clinicians and practitioners with effective skill selection. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. The Effects of Elbow Bracing on Medial Elbow Joint Space Gapping Associated With Repetitive Throwing in High School Baseball Players

    PubMed Central

    Hattori, Hiroshi; Akasaka, Kiyokazu; Otsudo, Takahiro; Takei, Keiichi; Yamamoto, Mitsuru

    2017-01-01

    Background: Throwing athletes risk medial elbow injury from extreme valgus stress generated across the medial elbow during throwing. Braces have been developed to protect the elbow joint; however, no previous study has investigated the effects of elbow bracing on medial elbow joint space gapping associated with repetitive throwing. Hypothesis/Purpose: The purpose of this study was to investigate the effects of elbow bracing on medial elbow joint space gapping during repetitive throwing. Our hypothesis was that an elbow brace may reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. Study Design: Controlled laboratory study. Methods: Twenty-five high school baseball players participated in this study. Each subject pitched 100 times under 2 conditions: control (without elbow brace) and elbow brace. The ulnohumeral joint space was measured ultrasonically before pitching and after every block of 20 pitches. Measurement of the ulnohumeral joint space was carried out using ultrasound with the forearm hanging by the side. Two-way repeated-measures analysis of variance and post hoc tests were used to compare ulnohumeral joint space with repeated pitching and between the elbow brace and control conditions. Results: In the control condition, ulnohumeral joint space after 60 pitches was significantly greater than that before pitching (P < .01). In contrast, in the elbow brace condition, ulnohumeral joint space was not significantly different after repeated pitching. When comparing these 2 conditions, ulnohumeral joint space in the control condition was significantly greater than that in the elbow brace condition after 60 pitches (P < .01). Conclusion: An elbow brace has the effect of preventing medial elbow joint space gapping with repeated throwing when determined ultrasonically by measuring the ulnohumeral joint space under gravity load. Clinical Relevance: An elbow brace worn during baseball pitching practice may help reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. PMID:28451622

  12. The Effects of Elbow Bracing on Medial Elbow Joint Space Gapping Associated With Repetitive Throwing in High School Baseball Players.

    PubMed

    Hattori, Hiroshi; Akasaka, Kiyokazu; Otsudo, Takahiro; Takei, Keiichi; Yamamoto, Mitsuru

    2017-04-01

    Throwing athletes risk medial elbow injury from extreme valgus stress generated across the medial elbow during throwing. Braces have been developed to protect the elbow joint; however, no previous study has investigated the effects of elbow bracing on medial elbow joint space gapping associated with repetitive throwing. The purpose of this study was to investigate the effects of elbow bracing on medial elbow joint space gapping during repetitive throwing. Our hypothesis was that an elbow brace may reduce mechanical stress on the elbow by reducing medial elbow joint space gapping. Controlled laboratory study. Twenty-five high school baseball players participated in this study. Each subject pitched 100 times under 2 conditions: control (without elbow brace) and elbow brace. The ulnohumeral joint space was measured ultrasonically before pitching and after every block of 20 pitches. Measurement of the ulnohumeral joint space was carried out using ultrasound with the forearm hanging by the side. Two-way repeated-measures analysis of variance and post hoc tests were used to compare ulnohumeral joint space with repeated pitching and between the elbow brace and control conditions. In the control condition, ulnohumeral joint space after 60 pitches was significantly greater than that before pitching ( P < .01). In contrast, in the elbow brace condition, ulnohumeral joint space was not significantly different after repeated pitching. When comparing these 2 conditions, ulnohumeral joint space in the control condition was significantly greater than that in the elbow brace condition after 60 pitches ( P < .01). An elbow brace has the effect of preventing medial elbow joint space gapping with repeated throwing when determined ultrasonically by measuring the ulnohumeral joint space under gravity load. An elbow brace worn during baseball pitching practice may help reduce mechanical stress on the elbow by reducing medial elbow joint space gapping.

  13. Ulnar Rotation Osteotomy for Congenital Radial Head Dislocation.

    PubMed

    Liu, Ruiyu; Miao, Wusheng; Mu, Mingchao; Wu, Ge; Qu, Jining; Wu, Yongtao

    2015-09-01

    To evaluate an ulnar rotation osteotomy for congenital anterior dislocation of the radial head. Nine patients (5 boys and 4 girls aged 6 to 13 years) with congenital anterior dislocation of the radial head were treated with ulnar rotation osteotomy. Magnetic resonance imaging of the elbow showed the proximal radioulnar joint on the anterior-lateral side of the ulna rather than on the lateral side in patients with congenital anterior dislocation of the radial head. On the basis of this finding, we performed an osteotomy on the ulna and laterally rotated the proximal radioulnar joint achieving radial head reduction and restoring the anatomical relationship between the radial head and the capitellum. Clinical and radiographical evaluation of the elbow was performed before surgery and at postoperative follow-up. All patients were followed for 13 to 45 months after surgery. Elbow radiography showed that the radiocapitellar joint was reduced in all patients at the last follow-up visit and that the carrying angle was decreased relative to that in the preoperative condition. Elbow stability and the range of elbow flexion motion were improved at the last follow-up. We did not observe ulnar osteotomy site nonunion or elbow osteoarthritis in these patients. Furthermore, radial head dislocation did not recur. At early follow-up, ulnar rotation osteotomy was a safe and effective method for the treatment of congenital anterior dislocation of the radial head. Therapeutic IV. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  14. The Posterior Bundle's Effect on Posteromedial Elbow Instability After a Transverse Coronoid Fracture: A Biomechanical Study.

    PubMed

    Shukla, Dave R; Golan, Elan; Weiser, Mitch C; Nasser, Philip; Choueka, Jack; Hausman, Michael

    2018-04-01

    There has been increased interest in the role of the posterior bundle of the medial collateral ligament (pMUCL) in the elbow, particularly its effects on posteromedial rotatory stability. The ligament's effect in the context of an unfixable coronoid fracture has not been the focus of any study. The purposes of this biomechanical study were to evaluate the stabilizing effect of the pMUCL with a transverse coronoid fracture and to assess the effect of graft reconstruction of the ligament. We simulated a varus and internal rotatory subluxation in 7 cadaveric elbows at 30°, 60°, and 90° elbow flexion. The amount of ulnar rotation and medial ulnohumeral joint gapping were assessed in the intact elbow after we created a transverse coronoid injury, after we divided the pMUCL, and finally, after we performed a graft reconstruction of the pMUCL. At all angles tested, some stability was lost after cutting the pMUCL once the coronoid had been injured, because mean proximal ulnohumeral joint gapping increased afterward by 2.1, 2.2, and 1.3 mm at 90°, 60°, and 30°, respectively. Ulnar internal rotation significantly increased after pMUCL transection at 90°. At 60° and 30° elbow flexion, ulnar rotation increased after resection of the coronoid but not after pMUCL resection. An uninjured pMUCL stabilizes against varus internal rotatory instability in the setting of a transverse coronoid fracture at higher flexion angles. Further research is needed to optimize graft reconstruction of the pMUCL. The pMUCL is an important secondary stabilizer against posteromedial instability in the coronoid-deficient elbow. In the setting of an unfixable coronoid fracture, the surgeon should examine for posteromedial instability and consider addressing the pMUCL surgically. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Resting Orientations of Dinosaur Scapulae and Forelimbs: A Numerical Analysis, with Implications for Reconstructions and Museum Mounts.

    PubMed

    Senter, Phil; Robins, James H

    2015-01-01

    The inclination of the scapular blade and the resting pose of the forelimb in dinosaurs differ among reconstructions and among skeletal mounts. For most dinosaurian taxa, no attempt has previously been made to quantify the correct resting positions of these elements. Here, we used data from skeletons preserved in articulation to quantify the resting orientations of the scapula and forelimb in dinosaurs. Specimens were included in the study only if they were preserved lying on their sides; for each specimen the angle between forelimb bones at a given joint was included in the analysis only if the joint was preserved in articulation. Using correlation analyses of the angles between the long axis of the sacrum, the first dorsal centrum, and the scapular blade in theropods and Eoraptor, we found that vertebral hyperextension does not influence scapular orientation in saurischians. Among examined taxa, the long axis of the scapular blade was found to be most horizontal in bipedal saurischians, most vertical in basal ornithopods, and intermediate in hadrosauroids. We found that in bipedal dinosaurs other than theropods with semilunate carpals, the resting orientation of the elbow is close to a right angle and the resting orientation of the wrist is such that the hand exhibits only slight ulnar deviation from the antebrachium. In theropods with semilunate carpals the elbow and wrist are more flexed at rest, with the elbow at a strongly acute angle and with the wrist approximately at a right angle. The results of our study have important implications for correct orientations of bones in reconstructions and skeletal mounts. Here, we provide recommendations on bone orientations based on our results.

  16. Effects of Angle Variations in Suspension Push-up Exercise.

    PubMed

    Gulmez, Irfan

    2017-04-01

    Gulmez, I. Effects of angle variations in suspension push-up exercise. J Strength Cond Res 31(4): 1017-1023, 2017-This study aimed to determine and compare the amount of loads on the TRX Suspension Trainer (TRX) straps and ground reaction forces at 4 different angles during TRX push-ups. Twenty-eight male (mean age, 24.1 ± 2.9 years; height, 179.4 ± 8.0 m; weight, 78.8 ± 9.8 kg) physical education and sports university students participated in this study. The subjects were tested at TRX angles (0, 15, 30, 45°) during the TRX push-ups. Force data were recorded by a force platform and load cells integrated into the TRX straps. The results show that as the TRX angle was reduced, the load applied to the TRX straps increased and simultaneously the load measured by the force platform decreased. This was true for both the elbow joint changing from flexion to extension and vice versa. When the TRX angle was set at 0° and subjects' elbows were at extension during TRX push-up, 50.4% of the subjects' body weight, and when the elbows were at flexion, 75.3% of the body weight was registered by the sensors on the TRX straps. The results of this study can be used in the calculation of the training load and volume (resistance training programming) during TRX push-up exercises at varying angles.

  17. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  18. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  19. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  20. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  1. 21 CFR 888.3170 - Elbow joint radial (hemi-elbow) polymer prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Elbow joint radial (hemi-elbow) polymer prosthesis. 888.3170 Section 888.3170 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... (hemi-elbow) polymer prosthesis. (a) Identification. An elbow joint radial (hemi-elbow) polymer...

  2. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  3. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  4. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  5. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Elbow joint metal/polymer semi-constrained... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal/polymer semi-constrained cemented prosthesis is a device intended to be implanted to replace an elbow...

  6. Influence of Joint Angle on EMG-Torque Model During Constant-Posture, Torque-Varying Contractions.

    PubMed

    Liu, Pu; Liu, Lukai; Clancy, Edward A

    2015-11-01

    Relating the electromyogram (EMG) to joint torque is useful in various application areas, including prosthesis control, ergonomics and clinical biomechanics. Limited study has related EMG to torque across varied joint angles, particularly when subjects performed force-varying contractions or when optimized modeling methods were utilized. We related the biceps-triceps surface EMG of 22 subjects to elbow torque at six joint angles (spanning 60° to 135°) during constant-posture, torque-varying contractions. Three nonlinear EMG σ -torque models, advanced EMG amplitude (EMG σ ) estimation processors (i.e., whitened, multiple-channel) and the duration of data used to train models were investigated. When EMG-torque models were formed separately for each of the six distinct joint angles, a minimum "gold standard" error of 4.01±1.2% MVC(F90) resulted (i.e., error relative to maximum voluntary contraction at 90° flexion). This model structure, however, did not directly facilitate interpolation across angles. The best model which did so achieved a statistically equivalent error of 4.06±1.2% MVC(F90). Results demonstrated that advanced EMG σ processors lead to improved joint torque estimation as do longer model training durations.

  7. A quantitative evaluation of the high elbow technique in front crawl.

    PubMed

    Suito, Hiroshi; Nunome, Hiroyuki; Ikegami, Yasuo

    2017-07-01

    Many coaches often instruct swimmers to keep the elbow in a high position (high elbow position) during early phase of the underwater stroke motion (pull phase) in front crawl, however, the high elbow position has never been quantitatively evaluated. The aims of this study were (1) to quantitatively evaluate the "high elbow" position, (2) to clarify the relationship between the high elbow position and required upper limb configuration and (3) to examine the efficacy of high elbow position on the resultant swimming velocity. Sixteen highly skilled and 6 novice male swimmers performed 25 m front crawl with maximal effort and their 3-dimensional arm stroke motion was captured at 60 Hz. An attempt was made to develop a new index to evaluate the high elbow position (I he : high elbow index) using 3-dimensional coordinates of the shoulder, elbow and wrist joints. I he of skilled swimmers moderately correlated with the average shoulder internal rotation angle (r = -0.652, P < 0.01) and swimming velocity (r = -0.683, P < 0.01) during the pull phase. These results indicate that I he is a useful index for evaluating high elbow arm stroke technique during the pull phase in front crawl.

  8. A Pilot Study of Individual Muscle Force Prediction during Elbow Flexion and Extension in the Neurorehabilitation Field

    PubMed Central

    Hou, Jiateng; Sun, Yingfei; Sun, Lixin; Pan, Bingyu; Huang, Zhipei; Wu, Jiankang; Zhang, Zhiqiang

    2016-01-01

    This paper proposes a neuromusculoskeletal (NMS) model to predict individual muscle force during elbow flexion and extension. Four male subjects were asked to do voluntary elbow flexion and extension. An inertial sensor and surface electromyography (sEMG) sensors were attached to subject's forearm. Joint angle calculated by fusion of acceleration and angular rate using an extended Kalman filter (EKF) and muscle activations obtained from the sEMG signals were taken as the inputs of the proposed NMS model to determine individual muscle force. The result shows that our NMS model can predict individual muscle force accurately, with the ability to reflect subject-specific joint dynamics and neural control solutions. Our method incorporates sEMG and motion data, making it possible to get a deeper understanding of neurological, physiological, and anatomical characteristics of human dynamic movement. We demonstrate the potential of the proposed NMS model for evaluating the function of upper limb movements in the field of neurorehabilitation. PMID:27916853

  9. Clinic research on the treatment for humeral shaft fracture with minimal invasive plate osteosynthesis: a retrospective study of 128 cases.

    PubMed

    Chen, H; Hu, X; Yang, G; Xiang, M

    2017-04-01

    Minimal invasive plate osteosynthesis (MIPO) is one of the most important techniques in the treatment for humeral shaft fractures. This study was performed to evaluate the efficacy of MIPO technique for the treatment for humeral shaft fractures. We retrospectively evaluated 128 cases with humeral shaft fractures that were treated with MIPO technique from March 2005 to August 2008. All the patients were followed up by routine radiological imaging and clinical examinations. Constant-Murley score and HSS elbow joint score were used to evaluate the treatment outcome. The average duration of the surgery was 60 min (range 40-95 min) without blood transfusion. All fractures healed without infection. All cases recovered carrying angle except four cases with 10°-15° cubitus varus. After the average follow-up of 23 (13-38) months, satisfactory function was achieved according to Constant-Murley score and HSS elbow joint score. Constant-Murley score was 80 on average (range 68-91). According to HSS elbow joint score, there were 123 cases of excellent clinical outcome and five cases of effective outcome. It seems to be a safe and effective method for managing humeral shaft fractures with MIPO technique.

  10. 21 CFR 888.3160 - Elbow joint metal/polymer semi-constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Elbow joint metal/polymer semi-constrained cemented prosthesis. 888.3160 Section 888.3160 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF... Elbow joint metal/polymer semi-constrained cemented prosthesis. (a) Identification. An elbow joint metal...

  11. [A new kinematics method of determing elbow rotation axis and evaluation of its feasibility].

    PubMed

    Han, W; Song, J; Wang, G Z; Ding, H; Li, G S; Gong, M Q; Jiang, X Y; Wang, M Y

    2016-04-18

    To study a new positioning method of elbow external fixation rotation axis, and to evaluate its feasibility. Four normal adult volunteers and six Sawbone elbow models were brought into this experiment. The kinematic data of five elbow flexion were collected respectively by optical positioning system. The rotation axes of the elbow joints were fitted by the least square method. The kinematic data and fitting results were visually displayed. According to the fitting results, the average moving planes and rotation axes were calculated. Thus, the rotation axes of new kinematic methods were obtained. By using standard clinical methods, the entrance and exit points of rotation axes of six Sawbone elbow models were located under X-ray. And The kirschner wires were placed as the representatives of rotation axes using traditional positioning methods. Then, the entrance point deviation, the exit point deviation and the angle deviation of two kinds of located rotation axes were compared. As to the four volunteers, the indicators represented circular degree and coplanarity of elbow flexion movement trajectory of each volunteer were both about 1 mm. All the distance deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 3 mm. All the angle deviations of the moving axes to the average moving rotation axes of the five volunteers were less than 5°. As to the six Sawbone models, the average entrance point deviations, the average exit point deviations and the average angle deviations of two different rotation axes determined by two kinds of located methods were respectively 1.697 2 mm, 1.838 3 mm and 1.321 7°. All the deviations were very small. They were all in an acceptable range of clinical practice. The values that represent circular degree and coplanarity of volunteer's elbow single curvature movement trajectory are very small. The result shows that the elbow single curvature movement can be regarded as the approximate fixed axis movement. The new method can replace the traditional method in accuracy. It can make up the deficiency of the traditional fixed axis method.

  12. Kinematic equations for control of the redundant eight-degree-of-freedom advanced research manipulator 2

    NASA Technical Reports Server (NTRS)

    Williams, Robert L., II

    1992-01-01

    The forward position and velocity kinematics for the redundant eight-degree-of-freedom Advanced Research Manipulator 2 (ARM2) are presented. Inverse position and velocity kinematic solutions are also presented. The approach in this paper is to specify two of the unknowns and solve for the remaining six unknowns. Two unknowns can be specified with two restrictions. First, the elbow joint angle and rate cannot be specified because they are known from the end-effector position and velocity. Second, one unknown must be specified from the four-jointed wrist, and the second from joints that translate the wrist, elbow joint excluded. There are eight solutions to the inverse position problem. The inverse velocity solution is unique, assuming the Jacobian matrix is not singular. A discussion of singularities is based on specifying two joint rates and analyzing the reduced Jacobian matrix. When this matrix is singular, the generalized inverse may be used as an alternate solution. Computer simulations were developed to verify the equations. Examples demonstrate agreement between forward and inverse solutions.

  13. Position sense at the human elbow joint measured by arm matching or pointing.

    PubMed

    Tsay, Anthony; Allen, Trevor J; Proske, Uwe

    2016-10-01

    Position sense at the human elbow joint has traditionally been measured in blindfolded subjects using a forearm matching task. Here we compare position errors in a matching task with errors generated when the subject uses a pointer to indicate the position of a hidden arm. Evidence from muscle vibration during forearm matching supports a role for muscle spindles in position sense. We have recently shown using vibration, as well as muscle conditioning, which takes advantage of muscle's thixotropic property, that position errors generated in a forearm pointing task were not consistent with a role by muscle spindles. In the present study we have used a form of muscle conditioning, where elbow muscles are co-contracted at the test angle, to further explore differences in position sense measured by matching and pointing. For fourteen subjects, in a matching task where the reference arm had elbow flexor and extensor muscles contracted at the test angle and the indicator arm had its flexors conditioned at 90°, matching errors lay in the direction of flexion by 6.2°. After the same conditioning of the reference arm and extension conditioning of the indicator at 0°, matching errors lay in the direction of extension (5.7°). These errors were consistent with predictions based on a role by muscle spindles in determining forearm matching outcomes. In the pointing task subjects moved a pointer to align it with the perceived position of the hidden arm. After conditioning of the reference arm as before, pointing errors all lay in a more extended direction than the actual position of the arm by 2.9°-7.3°, a distribution not consistent with a role by muscle spindles. We propose that in pointing muscle spindles do not play the major role in signalling limb position that they do in matching, but that other sources of sensory input should be given consideration, including afferents from skin and joint.

  14. Measurements of normal joint angles by goniometry in calves.

    PubMed

    Sengöz Şirin, O; Timuçin Celik, M; Ozmen, A; Avki, S

    2014-01-01

    The aim of this study was to establish normal reference values of the forelimb and hindlimb joint angles in normal Holstein calves. Thirty clinically normal Holstein calves that were free of any detectable musculoskeletal abnormalities were included in the study. A standard transparent plastic goniometer was used to measure maximum flexion, maximum extension, and range-of-motion of the shoulder, elbow, carpal, hip, stifle, and tarsal joints. The goniometric measurements were done on awake calves that were positioned in lateral recumbency. The goniometric values were measured and recorded by two independent investigators. As a result of the study it was concluded that goniometric values obtained from awake calves in lateral recumbency were found to be highly consistent and accurate between investigators (p <0.05). The data of this study acquired objective and useful information on the normal forelimb and hindlimb joint angles in normal Holstein calves. Further studies can be done to predict detailed goniometric values from different diseases and compare them.

  15. Influence of Passive Muscle Tension on Electromechanical Delay in Humans

    PubMed Central

    Lacourpaille, Lilian; Hug, François; Nordez, Antoine

    2013-01-01

    Background Electromechanical delay is the time lag between onsets of muscle activation and muscle force production and reflects both electro-chemical processes and mechanical processes. The aims of the present study were two-fold: to experimentally determine the slack length of each head of the biceps brachii using elastography and to determine the influence of the length of biceps brachii on electromechanical delay and its electro-chemical/mechanical processes using very high frame rate ultrasound. Methods/Results First, 12 participants performed two passive stretches to evaluate the change in passive tension for each head of the biceps brachii. Then, they underwent two electrically evoked contractions from 120 to 20° of elbow flexion (0°: full extension), with the echographic probe maintained over the muscle belly and the myotendinous junction of biceps brachii. The slack length was found to occur at 95.5 ± 6.3° and 95.3 ± 8.2° of the elbow joint angle for the long and short heads of the biceps brachii, respectively. The electromechanical delay was significantly longer at 120° (16.9 ± 3.1 ms; p<0.001), 110° (15.0 ± 3.1 ms; p<0.001) and 100° (12.7 ± 2.5 ms; p = 0.01) of elbow joint angle compared to 90° (11.1 ± 1.7 ms). However, the delay between the onset of electrical stimulation and the onset of both muscle fascicles (3.9 ± 0.2 ms) and myotendinous junction (3.7 ± 0.3 ms) motion was not significantly affected by the joint angle (p>0.95). Conclusion In contrast to previous observations on gastrocnemius medialis, the onset of muscle motion and the onset of myotendinous junction motion occurred simultaneously regardless of the length of the biceps brachii. That suggests that the between-muscles differences reported in the literature cannot be explained by different muscle passive tension but instead may be attributable to muscle architectural differences. PMID:23308153

  16. Long-latency reflexes of elbow and shoulder muscles suggest reciprocal excitation of flexors, reciprocal excitation of extensors, and reciprocal inhibition between flexors and extensors

    PubMed Central

    Meriggi, Jenna; Parikh, Nidhi; Saad, Kenneth

    2016-01-01

    Postural corrections of the upper limb are required in tasks ranging from handling an umbrella in the changing wind to securing a wriggling baby. One complication in this process is the mechanical interaction between the different segments of the arm where torque applied at one joint induces motion at multiple joints. Previous studies have shown the long-latency reflexes of shoulder muscles (50–100 ms after a limb perturbation) account for these mechanical interactions by integrating information about motion of both the shoulder and elbow. It is less clear whether long-latency reflexes of elbow muscles exhibit a similar capability and what is the relation between the responses of shoulder and elbow muscles. The present study utilized joint-based loads tailored to the subjects' arm dynamics to induce well-controlled displacements of their shoulder and elbow. Our results demonstrate that the long-latency reflexes of shoulder and elbow muscles integrate motion from both joints: the shoulder and elbow flexors respond to extension at both joints, whereas the shoulder and elbow extensors respond to flexion at both joints. This general pattern accounts for the inherent flexion-extension coupling of the two joints arising from the arm's intersegmental dynamics and is consistent with spindle-based reciprocal excitation of shoulder and elbow flexors, reciprocal excitation of shoulder and elbow extensors, and across-joint inhibition between the flexors and extensors. PMID:26864766

  17. The effect of repetitive baseball pitching on medial elbow joint space gapping associated with 2 elbow valgus stressors in high school baseball players.

    PubMed

    Hattori, Hiroshi; Akasaka, Kiyokazu; Otsudo, Takahiro; Hall, Toby; Amemiya, Katsuya; Mori, Yoshihisa

    2018-04-01

    To prevent elbow injury in baseball players, various methods have been used to measure medial elbow joint stability with valgus stress. However, no studies have investigated higher levels of elbow valgus stress. This study investigated medial elbow joint space gapping measured ultrasonically resulting from a 30 N valgus stress vs. gravitational valgus stress after a repetitive throwing task. The study included 25 high school baseball players. Each subject pitched 100 times. The ulnohumeral joint space was measured ultrasonographically, before pitching and after each successive block of 20 pitches, with gravity stress or 30 N valgus stress. Two-way repeated measures analysis of variance and Pearson correlation coefficient analysis were used. The 30 N valgus stress produced significantly greater ulnohumeral joint space gapping than gravity stress before pitching and at each successive 20-pitch block (P < .01). For the 2 stress methods, ulnohumeral joint space gapping increased significantly from baseline after 60 pitches (P < .01). Strong significant correlations were found between the 2 methods for measurement of medial elbow joint space gapping (r = 0.727-0.859, P < .01). Gravity stress and 30 N valgus stress may produce different effects with respect to medial elbow joint space gapping before pitching; however, 30 N valgus stress appears to induce greater mechanical stress, which may be preferable when assessing joint instability but also has the potential to be more aggressive. The present results may indicate that constraining factors to medial elbow joint valgus stress matched typical viscoelastic properties of cyclic creep. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  18. A primer for physical examination of the elbow.

    PubMed

    Zouzias, Ioannis C; Byram, Ian R; Shillingford, Jamal N; Levine, William N

    2012-02-01

    The elbow is a complex joint consisting of 3 separate but important articulations: the ulnohumeral, radiohumeral, and proximal radioulnar joints. The elbow assists in positioning the hand in space through 2 important motions, flexion-extension and pronation-supination. Although the elbow is not a weightbearing joint, it is subjected to significant loads, especially in overhead and throwing athletes. An accurate knowledge of the anatomy and physiology of the elbow joint is critical for conducting a focused physical examination and arriving at an accurate diagnosis. The goal of this article is to review general and focused physical examination of the elbow in a systematic manner based on medial, lateral, anterior, and posterior aspects.

  19. Configuration control of seven-degree-of-freedom arms

    NASA Technical Reports Server (NTRS)

    Seraji, Homayoun (Inventor); Long, Mark K. (Inventor); Lee, Thomas S. (Inventor)

    1992-01-01

    A seven degree of freedom robot arm with a six degree of freedom end effector is controlled by a processor employing a 6 by 7 Jacobian matrix for defining location and orientation of the end effector in terms of the rotation angles of the joints, a 1 (or more) by 7 Jacobian matrix for defining 1 (or more) user specified kinematic functions constraining location or movement of selected portions of the arm in terms of the joint angles, the processor combining the two Jacobian matrices to produce an augmented 7 (or more) by 7 Jacobian matrix, the processor effecting control by computing in accordance with forward kinematics from the augmented 7 by 7 Jacobian matrix and from the seven joint angles of the arm a set of seven desired joint angles for transmittal to the joint servo loops of the arm. One of the kinematic functions constraints the orientation of the elbow plane of the arm. Another one of the kinematic functions minimizes a sum of gravitational torques on the joints. Still another kinematic function constrains the location of the arm to perform collision avoidance. Generically, one kinematic function minimizes a sum of selected mechanical parameters of at least some of the joints associated with weighting coefficients which may be changed during arm movement. The mechanical parameters may be velocity errors or gravity torques associated with individual joints.

  20. Configuration control of seven degree of freedom arms

    NASA Technical Reports Server (NTRS)

    Seraji, Homayoun (Inventor)

    1995-01-01

    A seven-degree-of-freedom robot arm with a six-degree-of-freedom end effector is controlled by a processor employing a 6-by-7 Jacobian matrix for defining location and orientation of the end effector in terms of the rotation angles of the joints, a 1 (or more)-by-7 Jacobian matrix for defining 1 (or more) user-specified kinematic functions constraining location or movement of selected portions of the arm in terms of the joint angles, the processor combining the two Jacobian matrices to produce an augmented 7 (or more)-by-7 Jacobian matrix, the processor effecting control by computing in accordance with forward kinematics from the augmented 7-by-7 Jacobian matrix and from the seven joint angles of the arm a set of seven desired joint angles for transmittal to the joint servo loops of the arms. One of the kinematic functions constrains the orientation of the elbow plane of the arm. Another one of the kinematic functions minimizing a sum of gravitational torques on the joints. Still another one of the kinematic functions constrains the location of the arm to perform collision avoidance. Generically, one of the kinematic functions minimizes a sum of selected mechanical parameters of at least some of the joints associated with weighting coefficients which may be changed during arm movement. The mechanical parameters may be velocity errors or position errors or gravity torques associated with individual joints.

  1. Medial Elbow Joint Space Increases With Valgus Stress and Decreases When Cued to Perform A Maximal Grip Contraction.

    PubMed

    Pexa, Brett S; Ryan, Eric D; Myers, Joseph B

    2018-04-01

    Previous research indicates that the amount of valgus torque placed on the elbow joint during overhead throwing is higher than the medial ulnar collateral ligament (UCL) can tolerate. Wrist and finger flexor muscle activity is hypothesized to make up for this difference, and in vitro studies that simulated activity of upper extremity musculature, specifically the flexor digitorum superficialis and flexor carpi ulnaris, support this hypothesis. To assess the medial elbow joint space at rest, under valgus stress, and under valgus stress with finger and forearm flexor contraction by use of ultrasonography in vivo. Controlled laboratory study. Participants were 22 healthy males with no history of elbow dislocation or UCL injury (age, 21.25 ± 1.58 years; height, 1.80 ± 0.08 m; weight, 79.43 ± 18.50 kg). Medial elbow joint space was measured by use of ultrasonography during 3 separate conditions: at rest (unloaded), under valgus load (loaded), and with a maximal grip contraction under a valgus load (loaded-contracted) in both limbs. Participants lay supine with their arm abducted 90° and elbow flexed 30° with the forearm in full supination. A handgrip dynamometer was placed in the participants' hand to grip against during the contracted condition. Images were reduced in ImageJ to assess medial elbow joint space. A 2-way (condition × limb) repeated-measures analysis of variance and Cohen's d effect sizes were used to assess changes in medial elbow joint space. Post hoc testing was performed with a Bonferroni adjustment to assess changes within limb and condition. The medial elbow joint space was significantly larger in the loaded condition (4.91 ± 1.16 mm) compared with the unloaded condition (4.26 ± 1.23 mm, P < .001, d = 0.712) and the loaded-contracted condition (3.88 ± 0.94 mm, P < .001, d = 1.149). No significant change was found between the unloaded and loaded-contracted conditions ( P = .137). Medial elbow joint space increases under a valgus load and then decreases when a maximal grip contraction is performed. This indicates that wrist and finger flexor muscle contraction may assist in limiting medial elbow joint space, a result similar to findings of previous research in vitro. Muscle activation of the upper extremity limits the medial elbow joint space, suggesting that injury prevention programs for throwing athletes should incorporate exercises for the elbow, wrist, and hand to limit excessive medial elbow joint space gapping during activities that create high valgus load.

  2. Compensating for intersegmental dynamics across the shoulder, elbow, and wrist joints during feedforward and feedback control.

    PubMed

    Maeda, Rodrigo S; Cluff, Tyler; Gribble, Paul L; Pruszynski, J Andrew

    2017-10-01

    Moving the arm is complicated by mechanical interactions that arise between limb segments. Such intersegmental dynamics cause torques applied at one joint to produce movement at multiple joints, and in turn, the only way to create single joint movement is by applying torques at multiple joints. We investigated whether the nervous system accounts for intersegmental limb dynamics across the shoulder, elbow, and wrist joints during self-initiated planar reaching and when countering external mechanical perturbations. Our first experiment tested whether the timing and amplitude of shoulder muscle activity account for interaction torques produced during single-joint elbow movements from different elbow initial orientations and over a range of movement speeds. We found that shoulder muscle activity reliably preceded movement onset and elbow agonist activity, and was scaled to compensate for the magnitude of interaction torques arising because of forearm rotation. Our second experiment tested whether elbow muscles compensate for interaction torques introduced by single-joint wrist movements. We found that elbow muscle activity preceded movement onset and wrist agonist muscle activity, and thus the nervous system predicted interaction torques arising because of hand rotation. Our third and fourth experiments tested whether shoulder muscles compensate for interaction torques introduced by different hand orientations during self-initiated elbow movements and to counter mechanical perturbations that caused pure elbow motion. We found that the nervous system predicted the amplitude and direction of interaction torques, appropriately scaling the amplitude of shoulder muscle activity during self-initiated elbow movements and rapid feedback control. Taken together, our results demonstrate that the nervous system robustly accounts for intersegmental dynamics and that the process is similar across the proximal to distal musculature of the arm as well as between feedforward (i.e., self-initiated) and feedback (i.e., reflexive) control. NEW & NOTEWORTHY Intersegmental dynamics complicate the mapping between applied joint torques and the resulting joint motions. We provide evidence that the nervous system robustly predicts these intersegmental limb dynamics across the shoulder, elbow, and wrist joints during reaching and when countering external perturbations. Copyright © 2017 the American Physiological Society.

  3. Kinematics of the six-degree-of-freedom force-reflecting Kraft Master

    NASA Technical Reports Server (NTRS)

    Williams, Robert L., II

    1991-01-01

    Presented here are kinematic equations for a six degree of freedom force-reflecting hand controller. The forward kinematics solution is developed and shown in simplified form. The Jacobian matrix, which uses terms from the forward kinematics solution, is derived. Both of these kinematic solutions require joint angle inputs. A calibration method is presented to determine the hand controller joint angles given the respective potentiometer readings. The kinematic relationship describing the mechanical coupling between the hand and controller shoulder and elbow joints is given. These kinematic equations may be used in an algorithm to control the hand controller as a telerobotic system component. The purpose of the hand controller is two-fold: operator commands to the telerobotic system are entered using the hand controller, and contact forces and moments from the task are reflected to the operator via the hand controller.

  4. sEMG feature evaluation for identification of elbow angle resolution in graded arm movement.

    PubMed

    Castro, Maria Claudia F; Colombini, Esther L; Aquino, Plinio T; Arjunan, Sridhar P; Kumar, Dinesh K

    2014-11-25

    Automatic and accurate identification of elbow angle from surface electromyogram (sEMG) is essential for myoelectric controlled upper limb exoskeleton systems. This requires appropriate selection of sEMG features, and identifying the limitations of such a system.This study has demonstrated that it is possible to identify three discrete positions of the elbow; full extension, right angle, and mid-way point, with window size of only 200 milliseconds. It was seen that while most features were suitable for this purpose, Power Spectral Density Averages (PSD-Av) performed best. The system correctly classified the sEMG against the elbow angle for 100% cases when only two discrete positions (full extension and elbow at right angle) were considered, while correct classification was 89% when there were three discrete positions. However, sEMG was unable to accurately determine the elbow position when five discrete angles were considered. It was also observed that there was no difference for extension or flexion phases.

  5. Characteristics of upper limb muscular strength in male wheelchair tennis players

    PubMed Central

    Moon, Hyo-Bin; Park, Seung-Jae; Kim, Al-Chan; Jang, Jee-Hun

    2013-01-01

    The purpose of this study was to identify the characteristics of muscular strength in upper limb and to present the preliminary information for development of sports injury prevention program and exercise rehabilitation program in wheelchair tennis players. Participants were 12 male wheelchair tennis players. Muscular strength was measured in shoulder and elbow joints with isokinetic dynamometer. Ipsilateral (IR) and bilateral (BR) balance ratio were calculated with isokinetic strength at 60°/sec. As a result, extension strength (ES) was significantly higher than flexion strength (FS) (P< 0.001), and IR in both sides and BR in ES were maintained within normal range whereas BR in FS was lower than normal range in shoulder joint. In elbow joint FS was significantly higher than ES (P< 0.05), and IR and BR were lower than normal range. Consequently, the different tendency in IR between shoulder and elbow joints and lower IR and BR in elbow joints could be the characteristics in male wheelchair tennis players. It is suggested that flexor strengthening program in nondominant shoulder joint, extensor strengthening program in both elbow joint, and flexor strengthening program in non-dominant elbow joint should be introduced for male wheelchair tennis players. PMID:24278887

  6. In vivo axial humero-ulnar rotation in normal and dysplastic canine elbow joints.

    PubMed

    Rohwedder, Thomas; Fischer, Martin; Böttcher, Peter

    2018-04-01

    To prospectively compare relative axial (internal-external) humero-ulnar rotation in normal and dysplastic canine elbow joints. Six normal elbows (five dogs) and seven joints (six dogs) with coronoid disease were examined. After implantation of 0.8 mm tantalum beads into humerus and ulna, biplanar x-ray movies of the implanted elbows were taken while dogs were walking on a treadmill. Based on the 2D bead coordinates of the synchronized x-ray movies virtual 3D humero-ulnar animations were calculated. Based on these, relative internal-external humero-ulnar rotation was measured over the first third of stance phase and expressed as maximal rotational amplitude. Amplitudes from three consecutive steps were averaged and groupwise compared using an unpaired t-test. In normal elbow joints mean axial relative humero-ulnar rotation was 2.9° (SD 1.1). Dysplastic joints showed a significantly greater rotational amplitude (5.3°, SD 2.0; p = 0.0229, 95% confidence interval 0.4-4.4). Dysplastic elbow joints show greater relative internal-external humero-ulnar rotation compared to normal elbows, which might reflect rotational joint instability. Increased relative internal-external humero-ulnar rotation might alter physiological joint contact and pressure patterns. Future studies are needed to verify if this plays a role in the pathogenesis of medial coronoid disease. Schattauer GmbH.

  7. Analysis of elbow muscle strength parameters in Brazilian jiu-jitsu practitioners.

    PubMed

    Follmer, Bruno; Dellagrana, Rodolfo André; de Lima, Luis Antonio Pereira; Herzog, Walter; Diefenthaeler, Fernando

    2017-12-01

    Upper-body dynamic and isometric maximum strength are essential components for success in Brazilian jiu-jitsu (BJJ). This study was aimed at analysing strength parameters in the elbow flexor and extensor muscles of BJJ practitioners. Participants (n = 28) performed maximum isometric contractions of elbow flexors and extensors to determine peak torque (PT), rate of force development (RFD), and the torque-angle (T-A) relationship at elbow angles of 45°, 60°, 75°, 90°, 105°, and 120°. Additionally, concentric and eccentric PTs were measured at 1.04 rad·s -1 . Student t-test and ANOVA were performed using α = 0.05. Elbow flexors were stronger isometrically (P < 0.001, ES = 1.23) but weaker concentrically (P < 0.05, ES = 0.54) than extensor muscles, possibly because of the extensive grip disputes and pushing of opponents in BJJ. The T-A relationship had an inverted "U"-shape. Torque differences across elbow angles were moderate (ES = 0.62) for the extensor and large (ES = 0.92) for the flexor muscles. Isometric torque was greatest for elbow angles of 105° and 75° and smallest for 45° and 120° for extensor and flexor muscles, respectively. Elbow flexors had a greater RFD than extensors, regardless of elbow angle. The present study provides comprehensive results for elbow muscle strength in BJJ practitioners.

  8. Improper trunk rotation sequence is associated with increased maximal shoulder external rotation angle and shoulder joint force in high school baseball pitchers.

    PubMed

    Oyama, Sakiko; Yu, Bing; Blackburn, J Troy; Padua, Darin A; Li, Li; Myers, Joseph B

    2014-09-01

    In a properly coordinated throwing motion, peak pelvic rotation velocity is reached before peak upper torso rotation velocity, so that angular momentum can be transferred effectively from the proximal (pelvis) to distal (upper torso) segment. However, the effects of trunk rotation sequence on pitching biomechanics and performance have not been investigated. The aim of this study was to investigate the effects of trunk rotation sequence on ball speed and on upper extremity biomechanics that are linked to injuries in high school baseball pitchers. The hypothesis was that pitchers with improper trunk rotation sequence would demonstrate lower ball velocity and greater stress to the joint. Descriptive laboratory study. Three-dimensional pitching kinematics data were captured from 72 high school pitchers. Subjects were considered to have proper or improper trunk rotation sequences when the peak pelvic rotation velocity was reached either before or after the peak upper torso rotation velocity beyond the margin of error (±3.7% of the time from stride-foot contact to ball release). Maximal shoulder external rotation angle, elbow extension angle at ball release, peak shoulder proximal force, shoulder internal rotation moment, and elbow varus moment were compared between groups using independent t tests (α < 0.05). Pitchers with improper trunk rotation sequences (n = 33) demonstrated greater maximal shoulder external rotation angle (mean difference, 7.2° ± 2.9°, P = .016) and greater shoulder proximal force (mean difference, 9.2% ± 3.9% body weight, P = .021) compared with those with proper trunk rotation sequences (n = 22). No other variables differed significantly different between groups. High school baseball pitchers who demonstrated improper trunk rotation sequences demonstrated greater maximal shoulder external rotation angle and shoulder proximal force compared with pitchers with proper trunk rotation sequences. Improper sequencing of the trunk and torso alter upper extremity joint loading in ways that may influence injury risk. As such, exercises that reinforce the use of a proper trunk rotation sequence during the pitching motion may reduce the stress placed on the structures around the shoulder joint and lead to the prevention of injuries. © 2014 The Author(s).

  9. In vivo three-dimensional elbow biomechanics during forearm rotation.

    PubMed

    Omori, Shinsuke; Miyake, Junichi; Oka, Kunihiro; Tanaka, Hiroyuki; Yoshikawa, Hideki; Murase, Tsuyoshi

    2016-01-01

    It is unclear how elbow kinematics changes during forearm rotation. This study investigated in vivo 3-dimensional elbow kinematics during forearm rotation. We studied 12 normal elbows using in vivo 3-dimensional computed tomography data in maximum forearm supination, neutral, and maximum pronation with the elbows in extension. We measured the motion of the radius and ulna relative to the humerus using a markerless bone registration technique and the contact area of the radiocapitellar joint, proximal radioulnar joint, and ulnohumeral joint using a proximity mapping method. When the forearm rotated from the supinated position to the pronated position, the radius showed significant varus rotation, internal rotation, and extension relative to the humerus. The center of the radial head significantly translated anteriorly, proximally, and laterally. The ulna significantly rotated in valgus, and the deepest point on the sagittal ridge of the trochlear notch translated medially with forearm pronation. The contact area of the radiocapitellar joint was largest in pronation. The contact area of the proximal radioulnar joint was largest in supination. The contact area of the ulnohumeral joint showed no significant change during forearm rotation. In pronation, because of the proximal migration of the radial head, the radiocapitellar joint was most congruent compared with other positions. The proximal radioulnar joint was most congruent in supination. The ulnohumeral joint congruency was not affected by forearm rotation. This study provides useful information for understanding 3-dimensional elbow motion and joint osseous stability related to forearm rotation. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  10. Physical risk factors identification based on body sensor network combined to videotaping.

    PubMed

    Vignais, Nicolas; Bernard, Fabien; Touvenot, Gérard; Sagot, Jean-Claude

    2017-11-01

    The aim of this study was to perform an ergonomic analysis of a material handling task by combining a subtask video analysis and a RULA computation, implemented continuously through a motion capture system combining inertial sensors and electrogoniometers. Five workers participated to the experiment. Seven inertial measurement units, placed on the worker's upper body (pelvis, thorax, head, arms, forearms), were implemented through a biomechanical model of the upper body to continuously provide trunk, neck, shoulder and elbow joint angles. Wrist joint angles were derived from electrogoniometers synchronized with the inertial measurement system. Worker's activity was simultaneously recorded using video. During post-processing, joint angles were used as inputs to a computationally implemented ergonomic evaluation based on the RULA method. Consequently a RULA score was calculated at each time step to characterize the risk of exposure of the upper body (right and left sides). Local risk scores were also computed to identify the anatomical origin of the exposure. Moreover, the video-recorded work activity was time-studied in order to classify and quantify all subtasks involved into the task. Results showed that mean RULA scores were at high risk for all participants (6 and 6.2 for right and left sides respectively). A temporal analysis demonstrated that workers spent most part of the work time at a RULA score of 7 (right: 49.19 ± 35.27%; left: 55.5 ± 29.69%). Mean local scores revealed that most exposed joints during the task were elbows, lower arms, wrists and hands. Elbows and lower arms were indeed at a high level of risk during the total time of a work cycle (100% for right and left sides). Wrist and hands were also exposed to a risky level for much of the period of work (right: 82.13 ± 7.46%; left: 77.85 ± 12.46%). Concerning the subtask analysis, subtasks called 'snow thrower', 'opening the vacuum sealer', 'cleaning' and 'storing' have been identified as the most awkward for right and left sides given mean RULA scores and percentages of time spent at risky levels. Results analysis permitted to suggest ergonomic recommendations for the redesign of the workstation. Contributions of the proposed innovative system dedicated to physical ergonomic assessment are further discussed. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Revision ulnar collateral ligament reconstruction using a suspension button fixation technique.

    PubMed

    Lee, Gregory H; Limpisvasti, Orr; Park, Maxwell C; McGarry, Michelle H; Yocum, Lewis A; Lee, Thay Q

    2010-03-01

    Revision ulnar collateral ligament reconstruction remains a challenging problem. The objective of this study was to biomechanically evaluate an ulnar collateral ligament reconstruction technique using a suspension button fixation technique that can be used even in the case of ulnar cortical bone loss. An ulnar suspension fixation technique for ulnar collateral ligament reconstruction can restore elbow kinematics and demonstrate failure strength comparable to that of currently available techniques. Controlled laboratory study. Nine pairs of cadaveric elbows were dissected free of soft tissue and potted. After simulating ulnar cortical bone loss, ulnar collateral ligament reconstruction was performed in 1 elbow of each pair using palmaris longus autograft and a 30-mm RetroButton suspended from the far (lateralmost) ulnar cortex. A docking technique was used for humeral fixation of the graft. Elbow valgus angle was quantified using a Microscribe 3DLX digitizer at multiple elbow flexion angles. Valgus angle was measured with the ulnar collateral ligament intact, transected, and reconstructed. In addition, load-to-failure testing was performed in 1 elbow of each pair. Release of the ulnar collateral ligament caused a significant increase in valgus angle at each flexion angle tested (P < .002). Reconstructed elbows demonstrated no significant differences in valgus angle from the intact elbow at all flexion angles tested. Load-to-failure tests showed that reconstructed elbows had an ultimate torque (10.3 + or - 5.7 N x m) significantly less than intact elbows (26.4 + or - 10.6 N x m) (P = .001). Ulnar collateral ligament reconstruction using a suspension button fixation technique reliably restored elbow kinematics to the intact state. Load-to-failure testing demonstrated comparable fixation strength to several historic controls of primary reconstruction techniques despite the simulated ulnar cortical bone loss. Ulnar collateral ligament reconstruction using a suspension button fixation technique can be considered in the case of ulnar cortical bone loss in a primary or revision setting.

  12. 21 CFR 888.3180 - Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis. 888.3180 Section 888.3180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3180...

  13. 21 CFR 888.3180 - Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis. 888.3180 Section 888.3180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3180...

  14. 21 CFR 888.3180 - Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis. 888.3180 Section 888.3180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3180...

  15. 21 CFR 888.3180 - Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis. 888.3180 Section 888.3180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3180...

  16. 21 CFR 888.3180 - Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Elbow joint humeral (hemi-elbow) metallic uncemented prosthesis. 888.3180 Section 888.3180 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ORTHOPEDIC DEVICES Prosthetic Devices § 888.3180...

  17. Preliminary research of a novel center-driven robot for upper extremity rehabilitation.

    PubMed

    Cao, Wujing; Zhang, Fei; Yu, Hongliu; Hu, Bingshan; Meng, Qiaoling

    2018-01-19

    Loss of upper limb function often appears after stroke. Robot-assisted systems are becoming increasingly common in upper extremity rehabilitation. Rehabilitation robot provides intensive motor therapy, which can be performed in a repetitive, accurate and controllable manner. This study aims to propose a novel center-driven robot for upper extremity rehabilitation. A new power transmission mechanism is designed to transfer the power to elbow and shoulder joints from three motors located on the base. The forward and inverse kinematics equations of the center-driven robot (CENTROBOT) are deduced separately. The theoretical values of the scope of joint movements are obtained with the Denavit-Hartenberg parameters method. A prototype of the CENTROBOT is developed and tested. The elbow flexion/extension, shoulder flexion/extension and shoulder adduction/abduction can be realized of the center-driven robot. The angles value of joints are in conformity with the theoretical value. The CENTROBOT reduces the overall size of the robot arm, the influence of motor noise, radiation and other adverse factors by setting all motors on the base. It can satisfy the requirements of power and movement transmission of the robot arm.

  18. Elbow joint fatigue and bench-press training.

    PubMed

    Huang, Yen-Po; Chou, You-Li; Chen, Feng-Chun; Wang, Rong-Tyai; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2014-01-01

    Bench-press exercises are among the most common form of training exercise for the upper extremity because they yield a notable improvement in both muscle strength and muscle endurance. The literature contains various investigations into the effects of different bench-press positions on the degree of muscle activation. However, the effects of fatigue on the muscular performance and kinetics of the elbow joint are not understood fully. To investigate the effects of fatigue on the kinetics and myodynamic performance of the elbow joint in bench-press training. Controlled laboratory study. Motion research laboratory. A total of 18 physically healthy male students (age = 19.6 ± 0.8 years, height = 168.7 ± 5.5 cm, mass = 69.6 ± 8.6 kg) participated in the investigation. All participants were right-hand dominant, and none had a history of upper extremity injuries or disorders. Participants performed bench-press training until fatigued. Maximal possible number of repetitions, cycle time, myodynamic decline rate, elbow-joint force, and elbow-joint moment. We observed a difference in cycle time in the initial (2.1 ± 0.42 seconds) and fatigue (2.58 ± 0.46 seconds) stages of the bench-press exercise (P = .04). As the participants fatigued, we observed an increase in the medial-lateral force (P = .03) and internal-external moment (P ≤ .04) acting on the elbow joint. Moreover, a reduction in the elbow muscle strength was observed in the elbow extension-flexion (P ≤ .003) and forearm supination-pronation (P ≤ .001) conditions. The results suggest that performing bench-press exercises to the point of fatigue increases elbow-joint loading and may further increase the risk of injury. Therefore, when clinicians design bench-press exercise regimens for general athletic training, muscle strengthening, or physical rehabilitation, they should control carefully the maximal number of repetitions.

  19. Quantitative assessment of four men using above-elbow prosthetic control.

    PubMed

    Popat, R A; Krebs, D E; Mansfield, J; Russell, D; Clancy, E; Gill-Body, K M; Hogan, N

    1993-07-01

    We studied the relationship between kinematically unconstrained activities of daily living (ADL) tasks and a kinematically constrained task in above-elbow (AE) amputee subjects using myoelectrically controlled prostheses. Four men, 24 to 49 years old, with unilateral AE amputation wore a prosthesis interfaced to a programmable controller to emulate two different elbow control schemes, conventional velocity and a new "natural" controller. Subjects were timed during three ADL tasks--cutting meat, donning socks, and rolling dough--with both controllers. The prosthesis emulator was then connected to a crank device with a handle, and the subjects turned the crank from bottom to top positions in a vertical plane using each controller. Synergistic shoulder-elbow joint coordination required for crank turning was quantified as the maximum slope of the change in elbow torque versus the change in crank-angle. Performance between the two controllers differed significantly for the crank test but not for ADL tasks. One subject did not complete all crank turning tests. Positive canonical correlation of 0.77 was found between time and crank domain measures. We conclude that biomechanical assessments should be integrated with time-based clinical tests to comprehensively evaluate performance of AE amputee subjects with a myoelectric device.

  20. Upper extremity interaction with a helicopter side airbag: injury criteria for dynamic hyperextension of the female elbow joint.

    PubMed

    Duma, Stefan M; Hansen, Gail A; Kennedy, Eric A; Rath, Amber L; McNally, Craig; Kemper, Andrew R; Smith, Eric P; Brolinson, P Gunnar; Stitzel, Joel D; Davis, Martin B; Bass, Cameron R; Brozoski, Frederick T; McEntire, B Joseph; Alem, Nabih M; Crowley, John S

    2004-11-01

    This paper describes a three part analysis to characterize the interaction between the female upper extremity and a helicopter cockpit side airbag system and to develop dynamic hyperextension injury criteria for the female elbow joint. Part I involved a series of 10 experiments with an original Army Black Hawk helicopter side airbag. A 5(th) percentile female Hybrid III instrumented upper extremity was used to demonstrate side airbag upper extremity loading. Two out of the 10 tests resulted in high elbow bending moments of 128 Nm and 144 Nm. Part II included dynamic hyperextension tests on 24 female cadaver elbow joints. The energy source was a drop tower utilizing a three-point bending configuration to apply elbow bending moments matching the previously conducted side airbag tests. Post-test necropsy showed that 16 of the 24 elbow joint tests resulted in injuries. Injury severity ranged from minor cartilage damage to more moderate joint dislocations and severe transverse fractures of the distal humerus. Peak elbow bending moments ranged from 42.4 Nm to 146.3 Nm. Peak bending moment proved to be a significant indicator of any elbow injury (p = 0.02) as well as elbow joint dislocation (p = 0.01). Logistic regression analyses were used to develop single and multiple variate injury risk functions. Using peak moment data for the entire test population, a 50% risk of obtaining any elbow injury was found at 56 Nm while a 50% risk of sustaining an elbow joint dislocation was found at 93 Nm for the female population. These results indicate that the peak elbow bending moments achieved in Part I are associated with a greater than 90% risk for elbow injury. Subsequently, the airbag was re-designed in an effort to mitigate this as well as the other upper extremity injury risks. Part III assessed the redesigned side airbag module to ensure injury risks had been reduced prior to implementing the new system. To facilitate this, 12 redesigned side airbag deployments were conducted using the same procedures as Part I. Results indicate that the re-designed side airbag has effectively mitigated elbow injury risks induced by the original side airbag design. It is anticipated that this study will provide researchers with additional injury criteria for assessing upper extremity injury risk caused by both military and automotive side airbag deployments.

  1. Estimation of distal arm joint angles from EMG and shoulder orientation for transhumeral prostheses.

    PubMed

    Akhtar, Aadeel; Aghasadeghi, Navid; Hargrove, Levi; Bretl, Timothy

    2017-08-01

    In this paper, we quantify the extent to which shoulder orientation, upper-arm electromyography (EMG), and forearm EMG are predictors of distal arm joint angles during reaching in eight subjects without disability as well as three subjects with a unilateral transhumeral amputation and targeted reinnervation. Prior studies have shown that shoulder orientation and upper-arm EMG, taken separately, are predictors of both elbow flexion/extension and forearm pronation/supination. We show that, for eight subjects without disability, shoulder orientation and upper-arm EMG together are a significantly better predictor of both elbow flexion/extension during unilateral (R 2 =0.72) and mirrored bilateral (R 2 =0.72) reaches and of forearm pronation/supination during unilateral (R 2 =0.77) and mirrored bilateral (R 2 =0.70) reaches. We also show that adding forearm EMG further improves the prediction of forearm pronation/supination during unilateral (R 2 =0.82) and mirrored bilateral (R 2 =0.75) reaches. In principle, these results provide the basis for choosing inputs for control of transhumeral prostheses, both by subjects with targeted motor reinnervation (when forearm EMG is available) and by subjects without target motor reinnervation (when forearm EMG is not available). In particular, we confirm that shoulder orientation and upper-arm EMG together best predict elbow flexion/extension (R 2 =0.72) for three subjects with unilateral transhumeral amputations and targeted motor reinnervation. However, shoulder orientation alone best predicts forearm pronation/supination (R 2 =0.88) for these subjects, a contradictory result that merits further study. Copyright © 2017 Elsevier Ltd. All rights reserved.

  2. Mechanical interaction between neighboring muscles in human upper limb: Evidence for epimuscular myofascial force transmission in humans.

    PubMed

    Yoshitake, Yasuhide; Uchida, Daiki; Hirata, Kosuke; Mayfield, Dean L; Kanehisa, Hiroaki

    2018-06-06

    To confirm the existence of epimuscular myofascial force transmission in humans, this study examined if manipulating joint angle to stretch the muscle can alter the shear modulus of a resting adjacent muscle, and whether there are regional differences in this response. The biceps brachii (BB: manipulated muscle) and the brachialis (BRA: resting adjacent muscle) were deemed suitable for this study because they are neighboring, yet have independent tendons that insert onto different bones. In order to manipulate the muscle length of BB only, the forearm was passively set at supination, neutral, and pronation positions. For thirteen healthy young adult men, the shear modulus of BB and BRA was measured with shear-wave elastography at proximal and distal muscle regions for each forearm position and with the elbow joint angle at either 100° or 160°. At both muscle regions and both elbow positions, BB shear modulus increased as the forearm was rotated from a supinated to pronated position. Conversely, BRA shear modulus decreased as function of forearm position. The effect of forearm position on shear modulus was most pronounced in the distal muscle region when the elbow was at 160°. The observed alteration of shear modulus of the resting adjacent muscle indicates that epimuscular myofascial force transmission is present in the human upper limb. Consistent with this assertion, we found that the effect of muscle length on shear modulus in both muscles was region-dependent. Our results also suggest that epimuscular myofascial force transmission may be facilitated at stretched muscle lengths. Copyright © 2018 Elsevier Ltd. All rights reserved.

  3. Anterior and posterior bands of the anterior bundle in the elbow ulnar collateral ligament: ultrasound anatomy.

    PubMed

    Yoshida, Masahito; Goto, Hideyuki; Takenaga, Tetsuya; Tsuchiya, Atsushi; Sugimoto, Katsumasa; Musahl, Volker; Fu, Freddie; Otsuka, Takanobu

    2017-10-01

    The anterior oblique bundle (AOL) of the ulnar collateral ligament (UCL) is composed of anterior and posterior bands. This study evaluated the anatomy of the anterior and posterior bands in the AOL of the UCL for their separate visualization with ultrasound (US). We dissected 18 cadaveric elbow joints and recorded the direction of each band from the lateral view to determine the proper position for the US transducer. To determine the proper inclination of the transducer, we measured the inclinations of each band at the proximal and distal insertions from the transverse view. A paired t test was used for comparisons between both bands. Values of P < .05 were considered statistically significant. The mean angles of the directions in the anterior and posterior bands were 10° ± 4° and 24° ± 9°, respectively. At the medial epicondyle, the mean inclination angles of both bands were 61° ± 5° and 67° ± 5°, respectively. At the sublime tubercle, the mean inclination angles of both bands were 14° ± 7° and 44° ± 9°, respectively. The inclination angles at the proximal ulna and the directions in both bands were significantly different (P < .001). This study shows that the directions of both bands and inclination angles of the bony attachments in both bands can assist with correct placement of the US transducer and allow for separate visualization of each band. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Monitoring Human Performance During Suited Operations: A Technology Feasibility Study Using EMU Gloves

    NASA Technical Reports Server (NTRS)

    Bekdash, Omar; Norcross, Jason; McFarland, Shane

    2015-01-01

    Mobility tracking of human subjects while conducting suited operations still remains focused on the external movement of the suit and little is known about the human movement within it. For this study, accelerometers and bend sensitive resistors were integrated into a custom carrier glove to quantify range of motion and dexterity from within the pressurized glove environment as a first stage feasibility study of sensor hardware, integration, and reporting capabilities. Sensors were also placed on the exterior of the pressurized glove to determine if it was possible to compare a glove joint angle to the anatomical joint angle of the subject during tasks. Quantifying human movement within the suit was feasible, with accelerometers clearly detecting movements in the wrist and reporting expected joint angles at maximum flexion or extension postures with repeatability of plus or minus 5 degrees between trials. Bend sensors placed on the proximal interphalangeal and distal interphalangeal joints performed less well. It was not possible to accurately determine the actual joint angle using these bend sensors, but these sensors could be used to determine when the joint was flexed to its maximum and provide a general range of mobility needed to complete a task. Further work includes additional testing with accelerometers and the possible inclusion of hardware such as magnetometers or gyroscopes to more precisely locate the joint in 3D space. We hope to eventually expand beyond the hand and glove and develop a more comprehensive suit sensor suite to characterize motion across more joints (knee, elbow, shoulder, etc.) and fully monitor the human body operating within the suit environment.

  5. Distinct Inter-Joint Coordination during Fast Alternate Keystrokes in Pianists with Superior Skill.

    PubMed

    Furuya, Shinichi; Goda, Tatsushi; Katayose, Haruhiro; Miwa, Hiroyoshi; Nagata, Noriko

    2011-01-01

    Musical performance requires motor skills to coordinate the movements of multiple joints in the hand and arm over a wide range of tempi. However, it is unclear whether the coordination of movement across joints would differ for musicians with different skill levels and how inter-joint coordination would vary in relation to music tempo. The present study addresses these issues by examining the kinematics and muscular activity of the hand and arm movements of professional and amateur pianists who strike two keys alternately with the thumb and little finger at various tempi. The professionals produced a smaller flexion velocity at the thumb and little finger and greater elbow pronation and supination velocity than did the amateurs. The experts also showed smaller extension angles at the metacarpo-phalangeal joint of the index and middle fingers, which were not being used to strike the keys. Furthermore, muscular activity in the extrinsic finger muscles was smaller for the experts than for the amateurs. These findings indicate that pianists with superior skill reduce the finger muscle load during keystrokes by taking advantage of differences in proximal joint motion and hand postural configuration. With an increase in tempo, the experts showed larger and smaller increases in elbow velocity and finger muscle co-activation, respectively, compared to the amateurs, highlighting skill level-dependent differences in movement strategies for tempo adjustment. Finally, when striking as fast as possible, individual differences in the striking tempo among players were explained by their elbow velocities but not by their digit velocities. These findings suggest that pianists who are capable of faster keystrokes benefit more from proximal joint motion than do pianists who are not capable of faster keystrokes. The distinct movement strategy for tempo adjustment in pianists with superior skill would therefore ensure a wider range of musical expression.

  6. Distinct Inter-Joint Coordination during Fast Alternate Keystrokes in Pianists with Superior Skill

    PubMed Central

    Furuya, Shinichi; Goda, Tatsushi; Katayose, Haruhiro; Miwa, Hiroyoshi; Nagata, Noriko

    2011-01-01

    Musical performance requires motor skills to coordinate the movements of multiple joints in the hand and arm over a wide range of tempi. However, it is unclear whether the coordination of movement across joints would differ for musicians with different skill levels and how inter-joint coordination would vary in relation to music tempo. The present study addresses these issues by examining the kinematics and muscular activity of the hand and arm movements of professional and amateur pianists who strike two keys alternately with the thumb and little finger at various tempi. The professionals produced a smaller flexion velocity at the thumb and little finger and greater elbow pronation and supination velocity than did the amateurs. The experts also showed smaller extension angles at the metacarpo-phalangeal joint of the index and middle fingers, which were not being used to strike the keys. Furthermore, muscular activity in the extrinsic finger muscles was smaller for the experts than for the amateurs. These findings indicate that pianists with superior skill reduce the finger muscle load during keystrokes by taking advantage of differences in proximal joint motion and hand postural configuration. With an increase in tempo, the experts showed larger and smaller increases in elbow velocity and finger muscle co-activation, respectively, compared to the amateurs, highlighting skill level-dependent differences in movement strategies for tempo adjustment. Finally, when striking as fast as possible, individual differences in the striking tempo among players were explained by their elbow velocities but not by their digit velocities. These findings suggest that pianists who are capable of faster keystrokes benefit more from proximal joint motion than do pianists who are not capable of faster keystrokes. The distinct movement strategy for tempo adjustment in pianists with superior skill would therefore ensure a wider range of musical expression. PMID:21660290

  7. Biomechanical effects of mobile computer location in a vehicle cab.

    PubMed

    Saginus, Kyle A; Marklin, Richard W; Seeley, Patricia; Simoneau, Guy G; Freier, Stephen

    2011-10-01

    The objective of this research is to determine the best location to place a conventional mobile computer supported by a commercially available mount in a light truck cab. U.S. and Canadian electric utility companies are in the process of integrating mobile computers into their fleet vehicle cabs. There are no publications on the effect of mobile computer location in a vehicle cab on biomechanical loading, performance, and subjective assessment. The authors tested four locations of mobile computers in a light truck cab in a laboratory study to determine how location affected muscle activity of the lower back and shoulders; joint angles of the shoulders, elbows, and wrist; user performance; and subjective assessment. A total of 22 participants were tested in this study. Placing the mobile computer closer to the steering wheel reduced low back and shoulder muscle activity. Joint angles of the shoulders, elbows, and wrists were also closer to neutral angle. Biomechanical modeling revealed substantially less spinal compression and trunk muscle force. In general, there were no practical differences in performance between the locations. Subjective assessment indicated that users preferred the mobile computer to be as close as possible to the steering wheel. Locating the mobile computer close to the steering wheel reduces risk of injuries, such as low back pain and shoulder tendonitis. Results from the study can guide electric utility companies in the installation of mobile computers into vehicle cabs. Results may also be generalized to other industries that use trucklike vehicles, such as construction.

  8. A Prospective Study of Injuries and Injury Risk Factors Among Army Wheel Vehicle Mechanics

    DTIC Science & Technology

    2006-08-01

    metacarpalphalangeal joint and 110* at the proximal interphalangeal joint of the third finger . While keeping the forearm on the padded table surface...ground, then return to the starting point with elbows fully extended. For sit-up, the Soldier bent his knees at a 90’ angle, interlocked his fingers ...Wrist 5 5.4 Hand 2 2.2 Finger 3 3.3 Upper Back 1 1.1 Lower Back Lower Back 16 17.4 Pelvic Area 1 1.1 Anterior Thigh 1 1.1 Knee 17 18.5 Lower Body Calf 1

  9. Functional joint regeneration is achieved using reintegration mechanism in Xenopus laevis

    PubMed Central

    Yamada, Shigehito

    2016-01-01

    Abstract A functional joint requires integration of multiple tissues: the apposing skeletal elements should form an interlocking structure, and muscles should insert into skeletal tissues via tendons across the joint. Whereas newts can regenerate functional joints after amputation, Xenopus laevis regenerates a cartilaginous rod without joints, a “spike.” Previously we reported that the reintegration mechanism between the remaining and regenerated tissues has a significant effect on regenerating joint morphogenesis during elbow joint regeneration in newt. Based on this insight into the importance of reintegration, we amputated frogs’ limbs at the elbow joint and found that frogs could regenerate a functional elbow joint between the remaining tissues and regenerated spike. During regeneration, the regenerating cartilage was partially connected to the remaining articular cartilage to reform the interlocking structure of the elbow joint at the proximal end of the spike. Furthermore, the muscles of the remaining part inserted into the regenerated spike cartilage via tendons. This study might open up an avenue for analyzing molecular and cellular mechanisms of joint regeneration using Xenopus. PMID:27499877

  10. Elbow Joint Fatigue and Bench-Press Training

    PubMed Central

    Huang, Yen-Po; Chou, You-Li; Chen, Feng-Chun; Wang, Rong-Tyai; Huang, Ming-Jer; Chou, Paul Pei-Hsi

    2014-01-01

    Context: Bench-press exercises are among the most common form of training exercise for the upper extremity because they yield a notable improvement in both muscle strength and muscle endurance. The literature contains various investigations into the effects of different bench-press positions on the degree of muscle activation. However, the effects of fatigue on the muscular performance and kinetics of the elbow joint are not understood fully. Objective: To investigate the effects of fatigue on the kinetics and myodynamic performance of the elbow joint in bench-press training. Design: Controlled laboratory study. Setting: Motion research laboratory. Patients or Other Participants: A total of 18 physically healthy male students (age = 19.6 ± 0.8 years, height = 168.7 ± 5.5 cm, mass = 69.6 ± 8.6 kg) participated in the investigation. All participants were right-hand dominant, and none had a history of upper extremity injuries or disorders. Intervention(s): Participants performed bench-press training until fatigued. Main Outcome Measure(s): Maximal possible number of repetitions, cycle time, myodynamic decline rate, elbow-joint force, and elbow-joint moment. Results: We observed a difference in cycle time in the initial (2.1 ± 0.42 seconds) and fatigue (2.58 ± 0.46 seconds) stages of the bench-press exercise (P = .04). As the participants fatigued, we observed an increase in the medial-lateral force (P = .03) and internal-external moment (P ≤ .04) acting on the elbow joint. Moreover, a reduction in the elbow muscle strength was observed in the elbow extension-flexion (P ≤ .003) and forearm supination-pronation (P ≤ .001) conditions. Conclusions: The results suggest that performing bench-press exercises to the point of fatigue increases elbow-joint loading and may further increase the risk of injury. Therefore, when clinicians design bench-press exercise regimens for general athletic training, muscle strengthening, or physical rehabilitation, they should control carefully the maximal number of repetitions. PMID:24533529

  11. Kinematic analysis of the thoracic limb of healthy dogs during descending stair and ramp exercises.

    PubMed

    Kopec, Nadia L; Williams, Jane M; Tabor, Gillian F

    2018-01-01

    OBJECTIVE To compare the kinematics of the thoracic limb of healthy dogs during descent of stairs and a ramp with those during a trot across a flat surface (control). ANIMALS 8 privately owned dogs. PROCEDURES For each dog, the left thoracic limb was instrumented with 5 anatomic markers to facilitate collection of 2-D kinematic data during each of 3 exercises (descending stairs, descending a ramp, and trotting over a flat surface). The stair exercise consisted of 4 steps with a 35° slope. For the ramp exercise, a solid plank was placed over the steps to create a ramp with a 35° slope. For the flat exercise, dogs were trotted across a flat surface for 2 m. Mean peak extension, peak flexion, and range of movement (ROM) of the shoulder, elbow, and carpal joints were compared among the 3 exercises. RESULTS Mean ROM for the shoulder and elbow joints during the stair exercise were significantly greater than during the flat exercise. Mean peak extension of the elbow joint during the flat exercise was significantly greater than that during both the stair and ramp exercises. Mean peak flexion of the elbow joint during the stair exercise was significantly greater than that during the flat exercise. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that descending stairs may be beneficial for increasing the ROM of the shoulder and elbow joints of dogs. Descending stair exercises may increase elbow joint flexion, whereas flat exercises may be better for targeting elbow joint extension.

  12. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint.

    PubMed

    Vedrine, Bertrand

    2017-04-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation.

  13. Use of an elastic transarticular external fixator construct for immobilization of the elbow joint

    PubMed Central

    Vedrine, Bertrand

    2017-01-01

    Transarticular external skeletal fixation usually involves rigid bars that result in a stable but stiff joint. This study describes the technique and the outcome of an elastic transarticular external fixator (ETEF) applied to the elbow joint. Four cases of elbow luxation with collateral ligament injuries were managed with closed reduction and application of an ETEF to maintain the reduction. A triceps tendon avulsion was surgically managed before applying an ETEF. The clinical outcome was considered excellent in 2 cats, good in 2 dogs (1 elbow luxation and the avulsion of the triceps tendon), and poor in 1 dog presented for elbow luxation and a permanent neurological defect. The procedure was rapid, easy to perform, and inexpensive. All animals except the one with a neurological defect had an early return to weight bearing. This method maintains extension of the joint while permitting its motion thereby promoting rehabilitation. PMID:28373726

  14. Limb position sense, proprioceptive drift and muscle thixotropy at the human elbow joint

    PubMed Central

    Tsay, A; Savage, G; Allen, T J; Proske, U

    2014-01-01

    These experiments on the human forearm are based on the hypothesis that drift in the perceived position of a limb over time can be explained by receptor adaptation. Limb position sense was measured in 39 blindfolded subjects using a forearm-matching task. A property of muscle, its thixotropy, a contraction history-dependent passive stiffness, was exploited to place muscle receptors of elbow muscles in a defined state. After the arm had been held flexed and elbow flexors contracted, we observed time-dependent changes in the perceived position of the reference arm by an average of 2.8° in the direction of elbow flexion over 30 s (Experiment 1). The direction of the drift reversed after the arm had been extended and elbow extensors contracted, with a mean shift of 3.5° over 30 s in the direction of elbow extension (Experiment 2). The time-dependent changes could be abolished by conditioning elbow flexors and extensors in the reference arm at the test angle, although this led to large position errors during matching (±10°), depending on how the indicator arm had been conditioned (Experiments 3 and 4). When slack was introduced in the elbow muscles of both arms, by shortening muscles after the conditioning contraction, matching errors became small and there was no drift in position sense (Experiments 5 and 6). These experiments argue for a receptor-based mechanism for proprioceptive drift and suggest that to align the two forearms, the brain monitors the difference between the afferent signals from the two arms. PMID:24665096

  15. Phenotypic disparity of the elbow joint in domestic dogs and wild carnivores.

    PubMed

    Figueirido, Borja

    2018-05-16

    In this article, I use geometric morphometrics in 2D from a sample of 366 elbow joints to quantify phenotypic disparity in domestic dog breeds, in wild canids, and across the order Carnivora. The elbow joint is a well-established morphological indicator of forearm motion and, by extension, of functional adaptations towards locomotor or predatory behavior in living carnivores. The study of the elbow joint in domestic dogs allows the exploration of potential convergences between (i) pursuit predators and fast-running dogs, and (ii) ambush predators and fighting breeds. The results indicate that elbow shape disparity among domestic dogs exceeds that in wolves; it is comparable to the disparity of wild Caninae, but is significantly lower than the one observed throughout Canidae and Carnivora. Moreover, fast-running and fighting breeds are not convergent in elbow joint shape with extreme pursuit and ambush wild carnivores, respectively. The role of artificial selection and developmental constraints in shaping limb phenotypic disparity through the extremely fast evolution of the domestic dog is discussed in the light of this new evidence. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  16. Prevalence and inheritance of and selection for elbow arthrosis in Bernese mountain dogs and Rottweilers in Sweden and benefit: cost analysis of a screening and control program.

    PubMed

    Swenson, L; Audell, L; Hedhammar, A

    1997-01-15

    To determine the prevalence and charges over time in the prevalence of elbow arthrosis in Bernese Mountain Dogs and Rottweilers, to ascertain whether prevalence or severity of elbow arthrosis was associated with sex of the dogs, age at the time of elbow joint examination, or ancestral background, to determine the effects of selective breeding, and to conduct an economic evaluation of the elbow arthrosis program operated by the Swedish Kennel Club. Analysis of radiographic evaluations of elbow joint conformity. 4,515 dogs from 2 breeds registered by the Swedish Kennel Club. All radiographs were scrutinized by a single radiologist (LA), and elbow joint conformation was classified as normal or arthrotic, with the degree of arthrosis classified as 1, 2, or 3. Decreasing prevalence of elbow arthrosis corresponding to selection of breeding stock and high heritabilities was found. Sex differences were documented in both breeds, but with contradictory directions. This was interpreted as breed differences in the distribution of genes related to elbow arthrosis. Economic analyses showed that costs of screening and registration of elbow joints was less than the value of dogs estimated to have been saved from moderate and severe elbow arthrosis in both breeds. Documented effects of age suggest that all dogs should be screened at the same age, rather than screening a few dogs at an older, more revealing age. In screening and control programs based on an open registry with access to family records, decreasing prevalence of elbow arthrosis can be expected, and related to selection of breeding stock.

  17. Three-dimensional kinematic analysis of upper and lower limb motion during gait of post-stroke patients

    PubMed Central

    Carmo, A.A.; Kleiner, A.F.R.; Lobo da Costa, P.H.; Barros, R.M.L.

    2012-01-01

    The aim of this study was to analyze the alterations of arm and leg movements of patients during stroke gait. Joint angles of upper and lower limbs and spatiotemporal variables were evaluated in two groups: hemiparetic group (HG, 14 hemiparetic men, 53 ± 10 years) and control group (CG, 7 able-bodied men, 50 ± 4 years). The statistical analysis was based on the following comparisons (P ≤ 0.05): 1) right versus left sides of CG; 2) affected (AF) versus unaffected (UF) sides of HG; 3) CG versus both the affected and unaffected sides of HG, and 4) an intracycle comparison of the kinematic continuous angular variables between HG and CG. This study showed that the affected upper limb motion in stroke gait was characterized by a decreased range of motion of the glenohumeral (HG: 6.3 ± 4.5, CG: 20.1 ± 8.2) and elbow joints (AF: 8.4 ± 4.4, UF: 15.6 ± 7.6) on the sagittal plane and elbow joint flexion throughout the cycle (AF: 68.2 ± 0.4, CG: 46.8 ± 2.7). The glenohumeral joint presented a higher abduction angle (AF: 14.2 ± 1.6, CG: 11.5 ± 4.0) and a lower external rotation throughout the cycle (AF: 4.6 ± 1.2, CG: 22.0 ± 3.0). The lower limbs showed typical alterations of the stroke gait patterns. Thus, the changes in upper and lower limb motion of stroke gait were identified. The description of upper limb motion in stroke gait is new and complements gait analysis. PMID:22473324

  18. Open arthrolysis for elbow stiffness increases carrying angle but has no impact on functional recovery.

    PubMed

    Fan, Dapeng; Wang, Wei; Hildebrand, Kevin A; Fan, Cun-Yi

    2016-09-09

    With the exception of normal anatomic changes in the medial collateral ligament and radial head, other factors related to carrying angle changes have not been systematically studied. We reviewed patients who underwent open arthrolysis of the elbow, and evaluated if open arthrolysis could change carrying angle. We then identified factors associated with carrying angle changes. Fifty patients with a minimum of 24 months of follow-up after open arthrolysis were evaluated retrospectively. Preoperative and postoperative carrying angles were compared. The carrying angles of 36 elbows in 36 patients were unchanged after surgery (Group A), while the carrying angles of 14 elbows in 14 patients increased postoperatively (Group B). In Group A, mean postoperative extension and flexion were 7° (range 0-24°) and 125° (range 10-135°) respectively, while mean postoperative pronation and supination were 60° (range 50-80°) and 65° (range 30-85°), respectively. In Group B, mean postoperative extension and flexion were 25° (range 0-40°) and 128° (range 60-138°), while mean postoperative pronation and supination were 65° (range 45-85°) and 60° (range 45-75°), respectively. No significant difference in range of motion and Mayo Elbow Performance Score was observed between the two groups. During open arthrolysis, humeral trochlea debridement and techniques for improving forearm rotation could increase carrying angle. However, this had no impact on elbow functional recovery.

  19. Evaluating Suit Fit Using Performance Degradation

    NASA Technical Reports Server (NTRS)

    Margerum, Sarah E.; Cowley, Matthew; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar

    2012-01-01

    The Mark III planetary technology demonstrator space suit can be tailored to an individual by swapping the modular components of the suit, such as the arms, legs, and gloves, as well as adding or removing sizing inserts in key areas. A method was sought to identify the transition from an ideal suit fit to a bad fit and how to quantify this breakdown using a metric of mobility-based human performance data. To this end, the degradation of the range of motion of the elbow and wrist of the suit as a function of suit sizing modifications was investigated to attempt to improve suit fit. The sizing range tested spanned optimal and poor fit and was adjusted incrementally in order to compare each joint angle across five different sizing configurations. Suited range of motion data were collected using a motion capture system for nine isolated and functional tasks utilizing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm by itself. Findings indicated that no single joint drives the performance of the arm as a function of suit size; instead it is based on the interaction of multiple joints along a limb. To determine a size adjustment range where an individual can operate the suit at an acceptable level, a performance detriment limit was set. This user-selected limit reveals the task-dependent tolerance of the suit fit around optimal size. For example, the isolated joint motion indicated that the suit can deviate from optimal by as little as -0.6 in to -2.6 in before experiencing a 10% performance drop in the wrist or elbow joint. The study identified a preliminary method to quantify the impact of size on performance and developed a new way to gauge tolerances around optimal size.

  20. A Textile-Based Wearable Sensing Device Designed for Monitoring the Flexion Angle of Elbow and Knee Movements

    PubMed Central

    Shyr, Tien-Wei; Shie, Jing-Wen; Jiang, Chang-Han; Li, Jung-Jen

    2014-01-01

    In this work a wearable gesture sensing device consisting of a textile strain sensor, using elastic conductive webbing, was designed for monitoring the flexion angle of elbow and knee movements. The elastic conductive webbing shows a linear response of resistance to the flexion angle. The wearable gesture sensing device was calibrated and then the flexion angle-resistance equation was established using an assembled gesture sensing apparatus with a variable resistor and a protractor. The proposed device successfully monitored the flexion angle during elbow and knee movements. PMID:24577526

  1. Proximal and distal muscle fatigue differentially affect movement coordination

    PubMed Central

    Cowley, Jeffrey C.

    2017-01-01

    Muscle fatigue can cause people to change their movement patterns and these changes could contribute to acute or overuse injuries. However, these effects depend on which muscles are fatigued. The purpose of this study was to determine the differential effects of proximal and distal upper extremity muscle fatigue on repetitive movements. Fourteen subjects completed a repetitive ratcheting task before and after a fatigue protocol on separate days. The fatigue protocol either fatigued the proximal (shoulder flexor) or distal (finger flexor) muscles. Pre/Post changes in trunk, shoulder, elbow, and wrist kinematics were compared to determine how proximal and distal fatigue affected multi-joint movement patterns and variability. Proximal fatigue caused a significant increase (7°, p < 0.005) in trunk lean and velocity, reduced humeral elevation (11°, p < 0.005), and increased elbow flexion (4°, p < 0.01). In contrast, distal fatigue caused small but significant changes in trunk angles (2°, p < 0.05), increased velocity of wrench movement relative to the hand (17°/s, p < 0.001), and earlier wrist extension (4%, p < 0.005). Movement variability increased at proximal joints but not distal joints after both fatigue protocols (p < 0.05). Varying movements at proximal joints may help people adapt to fatigue at either proximal or distal joints. The identified differences between proximal and distal muscle fatigue adaptations could facilitate risk assessment of occupational tasks. PMID:28235005

  2. In-Vivo Measurement of Muscle Tension: Dynamic Properties of the MC Sensor during Isometric Muscle Contraction

    PubMed Central

    Đorđević, Srđan; Tomažič, Sašo; Narici, Marco; Pišot, Rado; Meglič, Andrej

    2014-01-01

    Skeletal muscle is the largest tissue structure in our body and plays an essential role for producing motion through integrated action with bones, tendons, ligaments and joints, for stabilizing body position, for generation of heat through cell respiration and for blood glucose disposal. A key function of skeletal muscle is force generation. Non-invasive and selective measurement of muscle contraction force in the field and in clinical settings has always been challenging. The aim of our work has been to develop a sensor that can overcome these difficulties and therefore enable measurement of muscle force during different contraction conditions. In this study, we tested the mechanical properties of a “Muscle Contraction” (MC) sensor during isometric muscle contraction in different length/tension conditions. The MC sensor is attached so that it indents the skin overlying a muscle group and detects varying degrees of tension during muscular contraction. We compared MC sensor readings over the biceps brachii (BB) muscle to dynamometric measurements of force of elbow flexion, together with recordings of surface EMG signal of BB during isometric contractions at 15° and 90° of elbow flexion. Statistical correlation between MC signal and force was very high at 15° (r = 0.976) and 90° (r = 0.966) across the complete time domain. Normalized SD or σN = σ/max(FMC) was used as a measure of linearity of MC signal and elbow flexion force in dynamic conditions. The average was 8.24% for an elbow angle of 90° and 10.01% for an elbow of angle 15°, which indicates high linearity and good dynamic properties of MC sensor signal when compared to elbow flexion force. The next step of testing MC sensor potential will be to measure tension of muscle-tendon complex in conditions when length and tension change simultaneously during human motion. PMID:25256114

  3. In-vivo measurement of muscle tension: dynamic properties of the MC sensor during isometric muscle contraction.

    PubMed

    Đorđević, Srđan; Tomažič, Sašo; Narici, Marco; Pišot, Rado; Meglič, Andrej

    2014-09-25

    Skeletal muscle is the largest tissue structure in our body and plays an essential role for producing motion through integrated action with bones, tendons, ligaments and joints, for stabilizing body position, for generation of heat through cell respiration and for blood glucose disposal. A key function of skeletal muscle is force generation. Non-invasive and selective measurement of muscle contraction force in the field and in clinical settings has always been challenging. The aim of our work has been to develop a sensor that can overcome these difficulties and therefore enable measurement of muscle force during different contraction conditions. In this study, we tested the mechanical properties of a "Muscle Contraction" (MC) sensor during isometric muscle contraction in different length/tension conditions. The MC sensor is attached so that it indents the skin overlying a muscle group and detects varying degrees of tension during muscular contraction. We compared MC sensor readings over the biceps brachii (BB) muscle to dynamometric measurements of force of elbow flexion, together with recordings of surface EMG signal of BB during isometric contractions at 15° and 90° of elbow flexion. Statistical correlation between MC signal and force was very high at 15° (r = 0.976) and 90° (r = 0.966) across the complete time domain. Normalized SD or σN = σ/max(FMC) was used as a measure of linearity of MC signal and elbow flexion force in dynamic conditions. The average was 8.24% for an elbow angle of 90° and 10.01% for an elbow of angle 15°, which indicates high linearity and good dynamic properties of MC sensor signal when compared to elbow flexion force. The next step of testing MC sensor potential will be to measure tension of muscle-tendon complex in conditions when length and tension change simultaneously during human motion.

  4. Effect of single dose radiation therapy on weight-bearing lameness in dogs with elbow osteoarthritis.

    PubMed

    Kapatkin, Amy S; Nordquist, Barbro; Garcia, Tanya C; Griffin, Maureen A; Theon, Alain; Kim, Sun; Hayashi, Kei

    2016-07-19

    To determine if a single low dose of radiation therapy in dogs with osteoarthritis of the elbow joint was associated with a detectable improvement in their lameness and pain as documented by force platform gait analysis. In this cohort longitudinal observational study, five Labrador Retrievers with lameness due to elbow osteoarthritis that was unresponsive to medical treatment were removed from all non-steroidal anti-inflammatory and analgesic medications. A single treatment of radiation therapy delivering 10 Gray was performed on the affected elbow joint(s). Force platform gait analysis was used to assess the ground reaction forces of a limb affected with elbow osteoarthritis both before and after radiation therapy. Significant differences occurred in the weight-bearing on an affected limb with elbow osteoarthritis after radiation therapy at weeks six and 14. Change due to treatment was particularly apparent in dogs with unilateral elbow osteoarthritis. Administering a single low dose of radiation therapy may have a short-term benefit in dogs with elbow osteoarthritis, which is similar to the evidence supporting the use of radiation therapy in horses with orthopaedic disease.

  5. New Design of a Soft Robotics Wearable Elbow Exoskeleton Based on Shape Memory Alloy Wire Actuators

    PubMed Central

    Cano, Enrique; Moreno, Luis; Blanco, Dolores

    2017-01-01

    The elbow joint is a complex articulation composed of the humeroulnar and humeroradial joints (for flexion-extension movement) and the proximal radioulnar articulation (for pronation-supination movement). During the flexion-extension movement of the elbow joint, the rotation center changes and this articulation cannot be truly represented as a simple hinge joint. The main goal of this project is to design and assemble a medical rehabilitation exoskeleton for the elbow with one degree of freedom for flexion-extension, using the rotation center for proper patient elbow joint articulation. Compared with the current solutions, which align the exoskeleton axis with the elbow axis, this offers an ergonomic physical human-robot interface with a comfortable interaction. The exoskeleton is actuated with shape memory alloy wire-based actuators having minimum rigid parts, for guiding the actuators. Thanks to this unusual actuation system, the proposed exoskeleton is lightweight and has low noise in operation with a simple design 3D-printed structure. Using this exoskeleton, these advantages will improve the medical rehabilitation process of patients that suffered stroke and will influence how their lifestyle will change to recover from these diseases and improve their ability with activities of daily living, thanks to brain plasticity. The exoskeleton can also be used to evaluate the real status of a patient, with stroke and even spinal cord injury, thanks to an elbow movement analysis. PMID:29104424

  6. New Design of a Soft Robotics Wearable Elbow Exoskeleton Based on Shape Memory Alloy Wire Actuators.

    PubMed

    Copaci, Dorin; Cano, Enrique; Moreno, Luis; Blanco, Dolores

    2017-01-01

    The elbow joint is a complex articulation composed of the humeroulnar and humeroradial joints (for flexion-extension movement) and the proximal radioulnar articulation (for pronation-supination movement). During the flexion-extension movement of the elbow joint, the rotation center changes and this articulation cannot be truly represented as a simple hinge joint. The main goal of this project is to design and assemble a medical rehabilitation exoskeleton for the elbow with one degree of freedom for flexion-extension, using the rotation center for proper patient elbow joint articulation. Compared with the current solutions, which align the exoskeleton axis with the elbow axis, this offers an ergonomic physical human-robot interface with a comfortable interaction. The exoskeleton is actuated with shape memory alloy wire-based actuators having minimum rigid parts, for guiding the actuators. Thanks to this unusual actuation system, the proposed exoskeleton is lightweight and has low noise in operation with a simple design 3D-printed structure. Using this exoskeleton, these advantages will improve the medical rehabilitation process of patients that suffered stroke and will influence how their lifestyle will change to recover from these diseases and improve their ability with activities of daily living, thanks to brain plasticity. The exoskeleton can also be used to evaluate the real status of a patient, with stroke and even spinal cord injury, thanks to an elbow movement analysis.

  7. Evaluating Suit Fit Using Performance Degradation

    NASA Technical Reports Server (NTRS)

    Margerum, Sarah E.; Cowley, Matthew; Harvill, Lauren; Benson, Elizabeth; Rajulu, Sudhakar

    2011-01-01

    The Mark III suit has multiple sizes of suit components (arm, leg, and gloves) as well as sizing inserts to tailor the fit of the suit to an individual. This study sought to determine a way to identify the point an ideal suit fit transforms into a bad fit and how to quantify this breakdown using mobility-based physical performance data. This study examined the changes in human physical performance via degradation of the elbow and wrist range of motion of the planetary suit prototype (Mark III) with respect to changes in sizing and as well as how to apply that knowledge to suit sizing options and improvements in suit fit. The methods implemented in this study focused on changes in elbow and wrist mobility due to incremental suit sizing modifications. This incremental sizing was within a range that included both optimum and poor fit. Suited range of motion data was collected using a motion analysis system for nine isolated and functional tasks encompassing the elbow and wrist joints. A total of four subjects were tested with motions involving both arms simultaneously as well as the right arm only. The results were then compared across sizing configurations. The results of this study indicate that range of motion may be used as a viable parameter to quantify at what stage suit sizing causes a detriment in performance; however the human performance decrement appeared to be based on the interaction of multiple joints along a limb, not a single joint angle. The study was able to identify a preliminary method to quantify the impact of size on performance and to develop a means to gauge tolerances around optimal size. More work is needed to improve the assessment of optimal fit and to compensate for multiple joint interactions.

  8. Prescribing joint co-ordinates during model preparation to improve inverse kinematic estimates of elbow joint angles.

    PubMed

    Wells, D J M; Alderson, J A; Dunne, J; Elliott, B C; Donnelly, C J

    2017-01-25

    To appropriately use inverse kinematic (IK) modelling for the assessment of human motion, a musculoskeletal model must be prepared 1) to match participant segment lengths (scaling) and 2) to align the model׳s virtual markers positions with known, experimentally derived kinematic marker positions (marker registration). The purpose of this study was to investigate whether prescribing joint co-ordinates during the marker registration process (within the modelling framework OpenSim) will improve IK derived elbow kinematics during an overhead sporting task. To test this, the upper limb kinematics of eight cricket bowlers were recorded during two testing sessions, with a different tester each session. The bowling trials were IK modelled twice: once with an upper limb musculoskeletal model prepared with prescribed participant specific co-ordinates during marker registration - MR PC - and once with the same model prepared without prescribed co-ordinates - MR; and by an established direct kinematic (DK) upper limb model. Whilst both skeletal model preparations had strong inter-tester repeatability (MR: Statistical Parametric Mapping (SPM1D)=0% different; MR PC : SPM1D=0% different), when compared with DK model elbow FE waveform estimates, IK estimates using the MR PC model (RMSD=5.2±2.0°, SPM1D=68% different) were in closer agreement than the estimates from the MR model (RMSD=44.5±18.5°, SPM1D=100% different). Results show that prescribing participant specific joint co-ordinates during the marker registration phase of model preparation increases the accuracy and repeatability of IK solutions when modelling overhead sporting tasks in OpenSim. Copyright © 2016 Elsevier Ltd. All rights reserved.

  9. Mathematical modelling as a tool to assessment of loads in volleyball player's shoulder joint during spike.

    PubMed

    Jurkojć, Jacek; Michnik, Robert; Czapla, Krzysztof

    2017-06-01

    This article deals with kinematic and kinetic conditions in volleyball attack and identifies loads in the shoulder joint. Joint angles and velocities of individual segments of upper limb were measured with the use of the motion capture system XSENS. Muscle forces and loads in skeletal system were calculated by means of mathematical model elaborated in AnyBody system. Spikes performed by players in the best and worst way were compared with each other. The relationships were found between reactions in shoulder joint and flexion/extension, abduction/adduction and rotation angles in the same joint and flexion/extension in the elbow joint. Reactions in shoulder joint varied from 591 N to 2001 N (in relation to body weight [BW] 83-328%). The analysis proved that hand velocity at the moment of the ball hit (which varied between 6.8 and 13.3 m s -1 ) influences on the value of reaction in joints, but positions of individual segments relative to each other are also crucial. It was also proved in objective way, that position of the upper limb during spike can be more or less harmful assuming that bigger reaction increases possibility of injury, what can be an indication for trainers and physiotherapists how to improve injury prevention.

  10. Intra-articular kinematics of the upper limb joints: a six degrees of freedom study of coupled motions.

    PubMed

    Cattrysse, Erik; Baeyens, Jean-Pierre; Van Roy, Peter; Van de Wiele, Olivier; Roosens, Tom; Clarys, Jan-Pieter

    In sport, leisure and certain occupational activities, joint lesions of the upper limb are very common. To understand their aetiology in order to prevent and treat these pathologies on a scientific basis, a comprehensive knowledge of the involved stress and kinematics is imperative. For many years intra-articular joint kinematics have been described hypothetically in terms of the convex-concave principle. This principle, however, has not been validated. The in vitro research on the acromioclavicular, glenohumeral and elbow joints was performed using an electromagnetic tracking device (Flock of Birds). By recalculating the positions of the trackers to an embedded coordinate system on the joint surface, the intra-articular joint movements can be analysed. Therefore, the bony configurations and articular surface features were registered with a 3D drawing stylus (Microscribe). Thirteen acromioclavicular joints, six glenohumeral joints and seven elbows were studied. The coupled intra-articular movements were analysed using the Euler angles and finite helical axis approaches. The results of the acromioclavicular joint analysis indicate that during movements in the scapular plane a superior rotation of the clavicle was coupled with an inferior translation and vice versa, whilst during movements in the plane perpendicular to the scapular plane the anterior rotation was coupled with an anterior translation and vice versa. In the glenohumeral joint, the abduction-elevation was coupled with an external rotation. In the humero-ulnar joint, the extension was coupled with an external rotation and varus movement. This intra-articular behaviour was in contradiction to currently accepted convex-concave concepts in arthrokinematics and manual therapy. The results may have major implications for manual therapy and orthopaedic medical practice.

  11. Analysis of elbow-joints misalignment in upper-limb exoskeleton.

    PubMed

    Malosio, Matteo; Pedrocchi, Nicola; Vicentini, Federico; Tosatti, Lorenzo Molinari

    2011-01-01

    This paper presents advantages of introducing elbow-joints misalignments in an exoskeleton for upper limb rehabilitation. Typical exoskeletons are characterized by axes of the device as much as possible aligned to the rotational axes of human articulations. This approach leads to advantages in terms of movements and torques decoupling, but can lead to limitations nearby the elbow singular configuration. A proper elbow axes misalignment between the exoskeleton and the human can improve the quality of collaborative rehabilitation therapies, in which a correct torque transmission from human articulations to mechanical joints of the device is required to react to torques generated by the patient. © 2011 IEEE

  12. A musculoskeletal model of the elbow joint complex

    NASA Technical Reports Server (NTRS)

    Gonzalez, Roger V.; Barr, Ronald E.; Abraham, Lawrence D.

    1993-01-01

    This paper describes a musculoskeletal model that represents human elbow flexion-extension and forearm pronation-supination. Musculotendon parameters and the skeletal geometry were determined for the musculoskeletal model in the analysis of ballistic elbow joint complex movements. The key objective was to develop a computational model, guided by optimal control, to investigate the relationship among patterns of muscle excitation, individual muscle forces, and movement kinematics. The model was verified using experimental kinematic, torque, and electromyographic data from volunteer subjects performing both isometric and ballistic elbow joint complex movements. In general, the model predicted kinematic and muscle excitation patterns similar to what was experimentally measured.

  13. Elbow kinematics during sit-to-stand and stand-to-sit movements.

    PubMed

    Packer, T L; Wyss, U P; Costigan, P A

    1993-11-01

    The sit-to-stand and stand-to-sit movements of 10 healthy women (mean age 52.4 years) were subjected to a descriptive analysis that yielded a definition of phases, determination of the peak angles reached, maximum angular velocity during each movement, and the sequencing of key events. While subjects showed little intrasubject variability, intersubject variability was evident. Subjects differed in the joint angles and angular velocity recorded, but the sequence of flexion/extension and rotation events were unchanged. Changes in direction of flexion/extension and rotation tended to occur very close in time, if not at the same time. Copyright © 1993. Published by Elsevier Ltd.

  14. Upper limb joint motion of two different user groups during manual wheelchair propulsion

    NASA Astrophysics Data System (ADS)

    Hwang, Seonhong; Kim, Seunghyeon; Son, Jongsang; Lee, Jinbok; Kim, Youngho

    2013-02-01

    Manual wheelchair users have a high risk of injury to the upper extremities. Recent studies have focused on kinematic and kinetic analyses of manual wheelchair propulsion in order to understand the physical demands on wheelchair users. The purpose of this study was to investigate upper limb joint motion by using a motion capture system and a dynamometer with two different groups of wheelchair users propelling their wheelchairs at different speeds under different load conditions. The variations in the contact time, release time, and linear velocity of the experienced group were all larger than they were in the novice group. The propulsion angles of the experienced users were larger than those of the novices under all conditions. The variances in the propulsion force (both radial and tangential) of the experienced users were larger than those of the novices. The shoulder joint moment had the largest variance with the conditions, followed by the wrist joint moment and the elbow joint moment. The variance of the maximum shoulder joint moment was over four times the variance of the maximum wrist joint moment and eight times the maximum elbow joint moment. The maximum joint moments increased significantly as the speed and load increased in both groups. Quick and significant manipulation ability based on environmental changes is considered an important factor in efficient propulsion. This efficiency was confirmed from the propulsion power results. Sophisticated strategies for efficient manual wheelchair propulsion could be understood by observation of the physical responses of each upper limb joint to changes in load and speed. We expect that the findings of this study will be utilized for designing a rehabilitation program to reduce injuries.

  15. Arm-eye coordination test to objectively quantify motor performance and muscles activation in persons after stroke undergoing robot-aided rehabilitation training: a pilot study.

    PubMed

    Song, Rong; Tong, Kai-Yu; Hu, Xiaoling; Li, Le; Sun, Rui

    2013-09-01

    This study designed an arm-eye coordination test to investigate the effectiveness of the robot-aided rehabilitation for persons after stroke. Six chronic poststroke subjects were recruited to attend a 20-session robot-aided rehabilitation training of elbow joint. Before and after the training program, subjects were asked to perform voluntary movements of elbow flection and extension by following sinusoidal trajectories at different velocities with visual feedback on their joint positions. The elbow angle and the electromyographic signal of biceps and triceps as well as clinical scores were evaluated together with the parameters. Performance was objectively quantified by root mean square error (RMSE), root mean square jerk (RMSJ), range of motion (ROM), and co-contraction index (CI). After 20 sessions, RMSE and ROM improved significantly in both the affected and the unaffected side based on two-way ANOVA (P < 0.05). There was significant lower RMSJ in the affected side at higher velocities (P < 0.05). There was significant negative correlation between average RMSE with different tracking velocities and Fugl-Meyer shoulder-elbow score (P < 0.05). There was also significant negative correlation between average RMSE and average ROM (P < 0.05), and moderate nonsignificant negative correlation with RMSJ, and CI. The characterization of velocity-dependent deficiencies, monitoring of training-induced improvement, and the correlation between quantitative parameters and clinical scales could enable the exploration of effects of different types of treatment and design progress-based training method to accelerate the processes of recovery.

  16. The Movement- and Load-Dependent Differences in the EMG Patterns of the Human Arm Muscles during Two-Joint Movements (A Preliminary Study)

    PubMed Central

    Tomiak, Tomasz; Abramovych, Tetiana I.; Gorkovenko, Andriy V.; Vereshchaka, Inna V.; Mishchenko, Viktor S.; Dornowski, Marcin; Kostyukov, Alexander I.

    2016-01-01

    Slow circular movements of the hand with a fixed wrist joint that were produced in a horizontal plane under visual guidance during conditions of action of the elastic load directed tangentially to the movement trajectory were studied. The positional dependencies of the averaged surface EMGs in the muscles of the elbow and shoulder joints were compared for four possible combinations in the directions of load and movements. The EMG intensities were largely correlated with the waves of the force moment computed for a corresponding joint in the framework of a simple geometrical model of the system: arm - experimental setup. At the same time, in some cases the averaged EMGs exit from the segments of the trajectory restricted by the force moment singular points (FMSPs), in which the moments exhibited altered signs. The EMG activities display clear differences for the eccentric and concentric zones of contraction that are separated by the joint angle singular points (JASPs), which present extreme at the joint angle traces. We assumed that the modeled patterns of FMSPs and JASPs may be applied for an analysis of the synergic interaction between the motor commands arriving at different muscles in arbitrary two-joint movements. PMID:27375496

  17. [Imaging of the elbow joint with focus MRI. Part 2: muscles, nerves and synovial membranes].

    PubMed

    Rehm, J; Zeifang, F; Weber, M-A

    2014-03-01

    This review article discusses the magnetic resonance imaging (MRI) features and pathological changes of muscles, nerves and the synovial lining of the elbow joint. Typical imaging findings are illustrated and discussed. In addition, the cross-sectional anatomy and anatomical variants, such as accessory muscles and plicae are discussed. Injuries of the muscles surrounding the elbow joint, as well as chronic irritation are particularly common in athletes. Morphological changes in MRI, for example tennis or golfer's elbow are typical and often groundbreaking. By adapting the examination sequences, imaging planes and slices, complete and incomplete tendon ruptures can be reliably diagnosed. Although the clinical and electrophysiological examinations form the basis for the diagnosis of peripheral neuropathies, MRI provides useful additional information about the precise localization due to its high resolution and good soft tissue contrast and helps to rule out differential diagnoses. Synovial diseases, such as inflammatory arthritis, proliferative diseases and also impinging plicae must be considered in the MRI diagnostics of the elbow joint.

  18. Determinants of shoulder and elbow flexion range: results from the San Antonio Longitudinal Study of Aging.

    PubMed

    Escalante, A; Lichtenstein, M J; Hazuda, H P

    1999-08-01

    To gain a knowledge of factors associated with impaired upper extremity range of motion (ROM) in order to understand pathways that lead to disability. Shoulder and elbow flexion range was measured in a cohort of 695 community-dwelling subjects aged 65 to 74 years. Associations between subjects' shoulder and elbow flexion ranges and their demographic and anthropometric characteristics, as well as the presence of diabetes mellitus or self-reported physician-diagnosed arthritis, were examined using multivariate regression models. The relationship between shoulder or elbow flexion range and subjects' functional reach was examined to explore the functional significance of ROM in these joints. The flexion range for the 4 joints studied was at least 120 degrees in nearly all subjects (> or = 99% of the subjects for each of the 4 joints). Multivariate models revealed significant associations between male sex, Mexican American ethnic background, the use of oral hypoglycemic drugs or insulin to treat diabetes mellitus, and a lower shoulder flexion range. A lower elbow flexion range was associated with male sex, increasing body mass index, and the use of oral hypoglycemic drugs or insulin. A higher shoulder or elbow flexion range was associated with a lower likelihood of having a short functional reach. The great majority of community-dwelling elderly have a flexion range of shoulder and elbow joints that can be considered functional. Diabetes mellitus and obesity are two potentially treatable factors associated with reduced flexion range of these two functionally important joints.

  19. Elbow Angle during a Simulated Task Requiring Fine Psychomotor Control.

    ERIC Educational Resources Information Center

    Colangelo, Gary A.; And Others

    1991-01-01

    This study examined elbow angle during a fine motor task (threading a needle), in the context of positions used in preclinical training exercises and assumed by practitioners performing dental procedures. The 101 subjects tended to choose an obtuse angle (mean of 125 degrees) and to vary this angle only slightly in repeated trials. (DB)

  20. Comparative study of phrenic and intercostal nerve transfers for elbow flexion after global brachial plexus injury.

    PubMed

    Liu, Yuzhou; Lao, Jie; Zhao, Xin

    2015-04-01

    Global brachial plexus injuries (BPIs) are devastating events frequently resulting in severe functional impairment. The widely used nerve transfer sources for elbow flexion in patients with global BPIs include intercostal and phrenic nerves. The aim of this study was to compare phrenic and intercostal nerve transfers for elbow flexion after global BPI. A retrospective review of 33 patients treated with phrenic and intercostal nerve transfer for elbow flexion in posttraumatic global root avulsion BPI was carried out. In the phrenic nerve transfer group, the phrenic nerve was transferred to the anterolateral bundle of the anterior division of the upper trunk (23 patients); in the intercostal nerve transfer group, three intercostal nerves were coapted to the anterolateral bundles of the musculocutaneous nerve. The British Medical Research Council (MRC) grading system, angle of elbow flexion, and electromyography (EMG) were used to evaluate the recovery of elbow flexion at least 3 years postoperatively. The efficiency of motor function in the phrenic nerve transfer group was 83%, while it was 70% in the intercostal nerve transfer group. The two groups were not statistically different in terms of the MRC grade (p=0.646) and EMG results (p=0.646). The outstanding rates of angle of elbow flexion were 48% and 40% in the phrenic and intercostal nerve transfer groups, respectively. There was no significant difference of outstanding rates in the angle of elbow flexion between the two groups. Phrenic nerve transfer had a higher proportion of good prognosis for elbow flexion than intercostal nerve transfer, but the effective and outstanding rate had no significant difference for biceps reinnervation between the two groups according to MRC grading, angle of elbow flexion, and EMG. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Risk factors for cartilage damage and osteoarthritis of the elbow joint: case-control study and systematic literature review.

    PubMed

    Spahn, Gunter; Lipfert, Jens Uwe; Maurer, Constance; Hartmann, Bernd; Schiele, Rainer; Klemm, Holm-Torsten; Grifka, Joachim; Hofmann, Gunther O

    2017-04-01

    This case-control study compares patients with healthy elbows to a group of symptomatic patients with cartilage damage/osteoarthritis. The control group (n = 126) was recruited during routine medical examinations of patients (general medical offices). Included in the case group were a total of 92 patients who were undergoing arthroscopy as a result of chronic elbow discomfort. All patients were questioned with regard to occupational stress and athletic stress. A significantly increased risk of cartilage damage/osteoarthritis was found with subjectively perceived increased stress in occupational settings: OR = 3.8 (95% CI 2.1-6.7); p < 0.001; for the individual stresses of the elbow joint in occupational settings, the following severities in effects were found: Exposure to heavy work OR = 3.9 (95% CI 2.2-6.8); Force OR = 3.7 (95% CI 2.1-6.5); Vibration OR = 4.6 (95% CI 2.5-8.5); Repetition OR = 9.2 (95% CI 3.6-23.3); p < 0.001. Elbow-stressing sport types represent a potential risk factor for the development of cartilage damage/osteoarthritis of the elbow joint: OR = 2.5 (95% CI 1.3-4.7); p = 0.003. Cartilage damage/radiographic osteoarthritis of the elbow joint are rare with respect to the overall prevalence of osteoarthritis. In the large number of patients with cartilage damage/radiographic osteoarthritis of the elbow joint, occupational or athletic stress factors and injuries sustained, in addition to other causes (rheumatism, gout), can prove as possible causes of these as secondary to symptomatic forms of osteoarthritis.

  2. The effects of rear-wheel camber on the kinematics of upper extremity during wheelchair propulsion

    PubMed Central

    2012-01-01

    Background The rear-wheel camber, defined as the inclination of the rear wheels, is usually used in wheelchair sports, but it is becoming increasingly employed in daily propulsion. Although the rear-wheel camber can increase stability, it alters physiological performance during propulsion. The purpose of the study is to investigate the effects of rear-wheel cambers on temporal-spatial parameters, joint angles, and propulsion patterns. Methods Twelve inexperienced subjects (22.3±1.6 yr) participated in the study. None had musculoskeletal disorders in their upper extremities. An eight-camera motion capture system was used to collect the three-dimensional trajectory data of markers attached to the wheelchair-user system during propulsion. All participants propelled the same wheelchair, which had an instrumented wheel with cambers of 0°, 9°, and 15°, respectively, at an average velocity of 1 m/s. Results The results show that the rear-wheel camber significantly affects the average acceleration, maximum end angle, trunk movement, elbow joint movement, wrist joint movement, and propulsion pattern. The effects are especially significant between 0° and 15°. For a 15° camber, the average acceleration and joint peak angles significantly increased (p < 0.01). A single loop pattern (SLOP) was adopted by most of the subjects. Conclusions The rear-wheel camber affects propulsion patterns and joint range of motion. When choosing a wheelchair with camber adjustment, the increase of joint movements and the base of support should be taken into consideration. PMID:23173938

  3. The effects of rear-wheel camber on the kinematics of upper extremity during wheelchair propulsion.

    PubMed

    Tsai, Chung-Ying; Lin, Chien-Ju; Huang, Yueh-Chu; Lin, Po-Chou; Su, Fong-Chin

    2012-11-22

    The rear-wheel camber, defined as the inclination of the rear wheels, is usually used in wheelchair sports, but it is becoming increasingly employed in daily propulsion. Although the rear-wheel camber can increase stability, it alters physiological performance during propulsion. The purpose of the study is to investigate the effects of rear-wheel cambers on temporal-spatial parameters, joint angles, and propulsion patterns. Twelve inexperienced subjects (22.3±1.6 yr) participated in the study. None had musculoskeletal disorders in their upper extremities. An eight-camera motion capture system was used to collect the three-dimensional trajectory data of markers attached to the wheelchair-user system during propulsion. All participants propelled the same wheelchair, which had an instrumented wheel with cambers of 0°, 9°, and 15°, respectively, at an average velocity of 1 m/s. The results show that the rear-wheel camber significantly affects the average acceleration, maximum end angle, trunk movement, elbow joint movement, wrist joint movement, and propulsion pattern. The effects are especially significant between 0° and 15°. For a 15° camber, the average acceleration and joint peak angles significantly increased (p < 0.01). A single loop pattern (SLOP) was adopted by most of the subjects. The rear-wheel camber affects propulsion patterns and joint range of motion. When choosing a wheelchair with camber adjustment, the increase of joint movements and the base of support should be taken into consideration.

  4. The morphologic change of the ulnar collateral ligament of elbow in high school baseball pitchers, with and without symptoms, by sonography.

    PubMed

    Tajika, Tsuyoshi; Yamamoto, Atsushi; Oya, Noboru; Ichinose, Tsuyoshi; Shimoyama, Daisuke; Sasaki, Tsuyoshi; Shitara, Hitoshi; Kitagawa, Takanori; Saito, Kenichi; Osawa, Takashi; Takagishi, Kenji

    2016-08-01

    Few reports in the literature relate morphologic changes of the ulnar collateral ligament (UCL) to prior elbow symptoms. This study used ultrasonography (US) to assess the ulnohumeral joint space width, with and without stress, and elucidate morphologic changes of the UCL of the elbow in high school pitchers with and without a history of elbow symptoms. Each of 122 high school baseball pitchers who underwent US of the medial aspect of both elbows completed a self-administered questionnaire related to the self-satisfaction score (0-100) for pitching performance and throwing-related elbow joint pain sustained during the prior 3 years. We conducted gravity stress US elbow examination with 30° of flexion with and without valgus stress. Comparisons of the UCL thickness and ulnohumeral joint space width, with and without valgus stress, were made among the 122 high school pitchers with and without a history of elbow symptoms. Pitchers with an elbow symptom history exhibited a greater difference between the UCL thickness on the throwing side than those with no elbow symptom history (P = .0013). A negative significant association was found between UCL thickness on the pitching side and the self-evaluation score for pitching performance (r = -0.20, P = .04). US assessment demonstrated that the UCL in the dominant side with elbow symptom history was thicker than that with no elbow symptom history. The UCL thickness might reflect the prior pitching condition of high school baseball pitchers. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  5. The influence of bar diameter on neuromuscular strength and activation: inferences from an isometric unilateral bench press.

    PubMed

    Fioranelli, Douglas; Lee, C Matthew

    2008-05-01

    The purpose of this study was to examine the influence of two different bar diameters on neuromuscular activation and strength. The bar diameters used reflected a standard Olympic bar (28 mm (1.1 inch); THIN) and a larger fat bar (51 mm [2 inch]; THICK). Eighteen healthy men (age 25.0 +/- 1 years) were assessed for their maximal voluntary contraction (MVC) during a unilateral isometric bench press exercise with the 2 bar types at 2 different joint angles (angle 1 and angle 2; elbow joint at approximately 45 and 90 degrees , respectively). Additionally, on a separate day, subjects performed three 10-second isometric repetitions at an intensity of 80% MVC using the 2 different bars at angle 1 and angle 2. Electromyographic recordings were collected in the pectoralis major and the muscles of the forearm flexor region at a sampling rate of 1000 Hz during the second day of testing. Analysis of variance was used to examine differences in MVC between bars and also examine between bar differences in electromyographic activity for each muscle group at each joint angle. A significance level of 0.05 was used for all tests. MVC was not different between bar types, although there was a main effect of joint angle on MVC such that it was greater at angle 2. There was a main effect of bar at both angles for the forearm muscles and at angle 1 for the pectoralis such that electromyographic activity was greater with THIN. Our data do not support the hypothesis that bar diameter influences performance during an isometric bench press exercise. However, higher electromyographic activity with THIN suggests greater neuromuscular activation with a standard Olympic bar as opposed to a larger diameter "fat" bar. Although our data do not support the use of a fat bar for increasing neuromuscular activation, these findings should be confirmed in other resistance training exercises.

  6. a Numerical Comparison of Langrange and Kane's Methods of AN Arm Segment

    NASA Astrophysics Data System (ADS)

    Rambely, Azmin Sham; Halim, Norhafiza Ab.; Ahmad, Rokiah Rozita

    A 2-D model of a two-link kinematic chain is developed using two dynamics equations of motion, namely Kane's and Lagrange Methods. The dynamics equations are reduced to first order differential equation and solved using modified Euler and fourth order Runge Kutta to approximate the shoulder and elbow joint angles during a smash performance in badminton. Results showed that Runge-Kutta produced a better and exact approximation than that of modified Euler and both dynamic equations produced better absolute errors.

  7. Isometric elbow extensors strength in supine- and prone-lying positions.

    PubMed

    Abdelzaher, Ibrahim E; Ababneh, Anas F; Alzyoud, Jehad M

    2013-01-01

    The purpose of this study was to compare isometric strength of elbow extensors measured in supine- and prone-lying positions at elbow flexion angles of 45 and 90 degrees. Twenty-two male subjects under single-blind procedures participated in the study. Each subject participated in both supine-lying and prone-lying measuring protocols. Calibrated cable tensiometer was used to measure isometric strength of the right elbow extensors and a biofeedback electromyography was used to assure no substitution movements from shoulder girdle muscles. The mean values of isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees were 11.1  ±  4.2 kg and 13.1  ±  4.6 kg, while those measured from prone-lying position were 9.9  ±  3.6 kg and 12  ±  4.2 kg, respectively. There is statistical significant difference between the isometric strength of elbow extensors measured from supine-lying position at elbow flexion angles of 45 and 90 degrees compared to that measured from prone-lying position (p  <  0.05). The results suggest that in manual muscle testing starting position can affect the isometric strength of elbow extensors since supine-lying starting position is better than prone-lying starting position.

  8. [Efficacies of arthroscopic debridement and olecranon fossa plasty in the treatment of osteoarthritis and posterior elbow impingement].

    PubMed

    Liu, Yu-jie; Wang, Jun-liang; Li, Hai-feng; Qi, Wei; Wang, Ning

    2012-07-17

    To evaluate the efficacies of arthroscopic debridement and removal of osteophyma for olecroanon and olecranon fossa plasty for posterior impingement of elbow joint. Between 1999 and 2008, a total of 21 cases were diagnosed with osteoarthritis and posterior elbow impingement. There were 15 males and 6 females. And there were 16 right and 15 left cases. They included volleyball players (n = 7), tennis players (n = 7), golf enthusiasts (n = 4) and fencers (n = 3). The average duration of onset-operation was 3.5 years (range: 2.5 - 8). Arthroscopic exploration revealed synovial hyperplasia hypertrophy, cartilage degeneration and olecranon fossa hyperplasia with deformed olecranon fossa. Debridement and plasty were performed. Loose bodies were removed from elbow joint in 6 patients. Partial resection of posterior olecranon tip was performed and osteophytes or fibrous tissue removed in this area. Dynamic observation showed no posterior elbow impingement. Postoperative follow-up was conducted in 19 cases and 2 cases became lost to follow-up. The average follow-up period was 25.3 months (range: 18 - 42). All patients were evaluated preoperatively and postoperatively with the Hospital for Special Surgery Elbow Assessment Scale. The outcomes were excellent (n = 12), good (n = 7) and fair (n = 2). Postoperative patients elbow swelling and pain relieve, sports and life function returns to normal, elbow flexion and rotating mobility obviously improved. With the elbow radiological films to measure the range of motion, the average range of motion was 90.5° preoperatively and improved to 130° postoperatively. There was significant improvement in all cases. Posterior elbow impingement is caused by hyperextension trauma and elbow overuse during specific sporting activities. Arthroscopic debridement and olecroanon or olecranon fossa plasty demonstrates excellent results for posterior impingement of elbow joint.

  9. Biomechanics of forearm rotation: force and efficiency of pronator teres.

    PubMed

    Ibáñez-Gimeno, Pere; Galtés, Ignasi; Jordana, Xavier; Malgosa, Assumpció; Manyosa, Joan

    2014-01-01

    Biomechanical models are useful to assess the effect of muscular forces on bone structure. Using skeletal remains, we analyze pronator teres rotational efficiency and its force components throughout the entire flexion-extension and pronation-supination ranges by means of a new biomechanical model and 3D imaging techniques, and we explore the relationship between these parameters and skeletal structure. The results show that maximal efficiency is the highest in full elbow flexion and is close to forearm neutral position for each elbow angle. The vertical component of pronator teres force is the highest among all components and is greater in pronation and elbow extension. The radial component becomes negative in pronation and reaches lower values as the elbow flexes. Both components could enhance radial curvature, especially in pronation. The model also enables to calculate efficiency and force components simulating changes in osteometric parameters. An increase of radial curvature improves efficiency and displaces the position where the radial component becomes negative towards the end of pronation. A more proximal location of pronator teres radial enthesis and a larger humeral medial epicondyle increase efficiency and displace the position where this component becomes negative towards forearm neutral position, which enhances radial curvature. Efficiency is also affected by medial epicondylar orientation and carrying angle. Moreover, reaching an object and bringing it close to the face in a close-to-neutral position improve efficiency and entail an equilibrium between the forces affecting the elbow joint stability. When the upper-limb skeleton is used in positions of low efficiency, implying unbalanced force components, it undergoes plastic changes, which improve these parameters. These findings are useful for studies on ergonomics and orthopaedics, and the model could also be applied to fossil primates in order to infer their locomotor form. Moreover, activity patterns in human ancient populations could be deduced from parameters reported here.

  10. Biomechanics principle of elbow joint for transhumeral prostheses: comparison of normal hand, body-powered, myoelectric & air splint prostheses.

    PubMed

    Abd Razak, Nasrul Anuar; Abu Osman, Noor Azuan; Gholizadeh, Hossein; Ali, Sadeeq

    2014-09-10

    Understanding of kinematics force applied at the elbow is important in many fields, including biomechanics, biomedical engineering and rehabilitation. This paper provides a comparison of a mathematical model of elbow joint using three different types of prosthetics for transhumeral user, and characterizes the forces required to overcome the passive mechanical of the prosthetics at the residual limb. The study modeled the elbow as a universal joint with intersecting axes of x-axis and y-axis in a plain of upper arm and lower arm. The equations of force applied, torque, weight and length of different type of prosthetics and the anthropometry of prosthetics hand are discussed in this study. The study also compares the force, torque and pressure while using all three types of prosthetics with the normal hand. The result was measured from the elbow kinematics of seven amputees, using three different types of prosthetics. The F-Scan sensor used in the study is to determine the pressure applied at the residual limb while wearing different type of prostheses. These technological advances in assessment the biomechanics of an elbow joint for three different type of prosthetics with the normal hand bring the new information for the amputees and prosthetist to choose the most suitable device to be worn daily.

  11. Evaluation of a computational model to predict elbow range of motion

    PubMed Central

    Nishiwaki, Masao; Johnson, James A.; King, Graham J. W.; Athwal, George S.

    2014-01-01

    Computer models capable of predicting elbow flexion and extension range of motion (ROM) limits would be useful for assisting surgeons in improving the outcomes of surgical treatment of patients with elbow contractures. A simple and robust computer-based model was developed that predicts elbow joint ROM using bone geometries calculated from computed tomography image data. The model assumes a hinge-like flexion-extension axis, and that elbow passive ROM limits can be based on terminal bony impingement. The model was validated against experimental results with a cadaveric specimen, and was able to predict the flexion and extension limits of the intact joint to 0° and 3°, respectively. The model was also able to predict the flexion and extension limits to 1° and 2°, respectively, when simulated osteophytes were inserted into the joint. Future studies based on this approach will be used for the prediction of elbow flexion-extension ROM in patients with primary osteoarthritis to help identify motion-limiting hypertrophic osteophytes, and will eventually permit real-time computer-assisted navigated excisions. PMID:24841799

  12. Dynamic Analysis of the Abnormal Isometric Strength Movement Pattern between Shoulder and Elbow Joint in Patients with Hemiplegia.

    PubMed

    Liu, Yali; Hong, Yuezhen; Ji, Linhong

    2018-01-01

    Patients with hemiplegia usually have weak muscle selectivity and usually perform strength at a secondary joint (secondary strength) during performing a strength at one joint (primary strength). The abnormal strength pattern between shoulder and elbow joint has been analyzed by the maximum value while the performing process with strength changing from 0 to maximum then to 0 was a dynamic process. The objective of this study was to develop a method to dynamically analyze the strength changing process. Ten patients were asked to perform four group asks (maximum and 50% maximum voluntary strength in shoulder abduction, shoulder adduction, elbow flexion, and elbow extension). Strength and activities from seven muscles were measured. The changes of secondary strength had significant correlation with those of primary strength in all tasks ( R > 0.76, p < 0.01). The antagonistic muscles were moderately influenced by the primary strength ( R > 0.4, p < 0.01). Deltoid muscles, biceps brachii, triceps brachii, and brachioradialis had significant influences on the abnormal strength pattern (all p < 0.01). The dynamic method was proved to be efficient to analyze the different influences of muscles on the abnormal strength pattern. The muscles, deltoid muscles, biceps brachii, triceps brachii, and brachioradialis, much influenced the stereotyped movement pattern between shoulder and elbow joint.

  13. Assessment and prediction of inter-joint upper limb movement correlations based on kinematic analysis and statistical regression

    NASA Astrophysics Data System (ADS)

    Toth-Tascau, Mirela; Balanean, Flavia; Krepelka, Mircea

    2013-10-01

    Musculoskeletal impairment of the upper limb can cause difficulties in performing basic daily activities. Three dimensional motion analyses can provide valuable data of arm movement in order to precisely determine arm movement and inter-joint coordination. The purpose of this study was to develop a method to evaluate the degree of impairment based on the influence of shoulder movements in the amplitude of elbow flexion and extension based on the assumption that a lack of motion of the elbow joint will be compensated by an increased shoulder activity. In order to develop and validate a statistical model, one healthy young volunteer has been involved in the study. The activity of choice simulated blowing the nose, starting from a slight flexion of the elbow and raising the hand until the middle finger touches the tip of the nose and return to the start position. Inter-joint coordination between the elbow and shoulder movements showed significant correlation. Statistical regression was used to fit an equation model describing the influence of shoulder movements on the elbow mobility. The study provides a brief description of the kinematic analysis protocol and statistical models that may be useful in describing the relation between inter-joint movements of daily activities.

  14. Dynamic Analysis of the Abnormal Isometric Strength Movement Pattern between Shoulder and Elbow Joint in Patients with Hemiplegia

    PubMed Central

    2018-01-01

    Patients with hemiplegia usually have weak muscle selectivity and usually perform strength at a secondary joint (secondary strength) during performing a strength at one joint (primary strength). The abnormal strength pattern between shoulder and elbow joint has been analyzed by the maximum value while the performing process with strength changing from 0 to maximum then to 0 was a dynamic process. The objective of this study was to develop a method to dynamically analyze the strength changing process. Ten patients were asked to perform four group asks (maximum and 50% maximum voluntary strength in shoulder abduction, shoulder adduction, elbow flexion, and elbow extension). Strength and activities from seven muscles were measured. The changes of secondary strength had significant correlation with those of primary strength in all tasks (R > 0.76, p < 0.01). The antagonistic muscles were moderately influenced by the primary strength (R > 0.4, p < 0.01). Deltoid muscles, biceps brachii, triceps brachii, and brachioradialis had significant influences on the abnormal strength pattern (all p < 0.01). The dynamic method was proved to be efficient to analyze the different influences of muscles on the abnormal strength pattern. The muscles, deltoid muscles, biceps brachii, triceps brachii, and brachioradialis, much influenced the stereotyped movement pattern between shoulder and elbow joint. PMID:29610654

  15. Biomechanics of the elbow joint in tennis players and relation to pathology

    PubMed Central

    Eygendaal, Denise; Rahussen, F T G; Diercks, R L

    2007-01-01

    Elbow injuries constitute a sizeable percentage of tennis injuries. A basic understanding of biomechanics of tennis and analysis of the forces, loads and motions of the elbow during tennis will improve the understanding of the pathophysiology of these injuries. All different strokes in tennis have a different repetitive biomechanical nature that can result in tennis‐related injuries. In this article, a biomechanically‐based evaluation of tennis strokes is presented. This overview includes all tennis‐related pathologies of the elbow joint, whereby the possible relation of biomechanics to pathology is analysed, followed by treatment recommendations. PMID:17638843

  16. Biomechanics of the elbow joint in tennis players and relation to pathology.

    PubMed

    Eygendaal, Denise; Rahussen, F Th G; Diercks, R L

    2007-11-01

    Elbow injuries constitute a sizeable percentage of tennis injuries. A basic understanding of biomechanics of tennis and analysis of the forces, loads and motions of the elbow during tennis will improve the understanding of the pathophysiology of these injuries. All different strokes in tennis have a different repetitive biomechanical nature that can result in tennis-related injuries. In this article, a biomechanically-based evaluation of tennis strokes is presented. This overview includes all tennis-related pathologies of the elbow joint, whereby the possible relation of biomechanics to pathology is analysed, followed by treatment recommendations.

  17. Influence of Input Hardware and Work Surface Angle on Upper Limb Posture in a Hybrid Computer Workstation.

    PubMed

    Kingston, David C; Riddell, Maureen F; McKinnon, Colin D; Gallagher, Kaitlin M; Callaghan, Jack P

    2016-02-01

    We evaluated the effect of work surface angle and input hardware on upper-limb posture when using a hybrid computer workstation. Offices use sit-stand and/or tablet workstations to increase worker mobility. These workstations may have negative effects on upper-limb joints by increasing time spent in non-neutral postures, but a hybrid standing workstation may improve working postures. Fourteen participants completed office tasks in four workstation configurations: a horizontal or sloped 15° working surface with computer or tablet hardware. Three-dimensional right upper-limb postures were recorded during three tasks: reading, form filling, and writing e-mails. Amplitude probability distribution functions determined the median and range of upper-limb postures. The sloped-surface tablet workstation decreased wrist ulnar deviation by 5° when compared to the horizontal-surface computer when reading. When using computer input devices (keyboard and mouse), the shoulder, elbow, and wrist were closest to neutral joint postures when working on a horizontal work surface. The elbow was 23° and 15° more extended, whereas the wrist was 6° less ulnar deviated, when reading compared to typing forms or e-mails. We recommend that the horizontal-surface computer configuration be used for typing and the sloped-surface tablet configuration be used for intermittent reading tasks in this hybrid workstation. Offices with mobile employees could use this workstation for alternating their upper-extremity postures; however, other aspects of the device need further investigation. © 2015, Human Factors and Ergonomics Society.

  18. Revisiting the anatomy and biomechanics of the anconeus muscle and its role in elbow stability.

    PubMed

    Pereira, Barry P

    2013-07-01

    Recent studies have designated the anconeus muscle as an option for use as a pedicled flap for covering soft tissue defects about the elbow, with reported minimal risk of morbidity. This has raised the question as to the importance of the anconeus muscle and as to whether this is truly an accessory muscle that can be sacrificed, or whether the anconeus muscle significantly contributes to elbow and forearm stability? This study revisits the anatomy and biomechanics of the anconeus muscle and aims to investigate the neuromuscular compartments of the anconeus muscle and to determine the changes in the muscle length, fibre length and moment arm over a range of elbow flexion angles for each compartment. An anatomical study on 8 human cadavers (51-77 years of age) was done and a 2-dimensional kinematic elbow model developed to determine changes in the muscle length and moment arm of the muscle related to changes in elbow flexion angles. The muscle was modelled with two possible lines of action, one along the posterior and another on the anterior edge of the muscle as they had different muscle fibre lengths (posterior: average of 32 mm, anterior: average of 20 mm). The anterior edge also had an aponeurosis which was 70% of its length. From 0 to 120° elbow flexion, the length of the posterior and anterior edges increased with a maximum change recorded at 90° elbow flexion (31.7±1.0 mm and 65.3±1.4 mm, respectively). The moment arm is 14-mm at 0° flexion, but between the posterior and anterior edges it decreases at different rates with increasing elbow flexion angle. Beyond 80°, the anterior edge behaves as an elbow flexor, while the posterior edge remains an elbow extensor. The study demonstrates that the anconeus muscle has two neuromuscular compartments each with distinct intramuscular innervations and muscle fibre lengths. The posterior and deep aspect of the muscle functions as an elbow extensor decreasing in influence with increasing elbow flexion angle. The anterior superficial aspect which is adjacent and parallel to the lateral collateral ligaments, would most likely work in unison to provide constraint to the posterolateral stability of the elbow. Copyright © 2012. Published by Elsevier GmbH.

  19. Rehabilitation of the Overhead Athlete’s Elbow

    PubMed Central

    Wilk, Kevin E.; Macrina, Leonard C.; Cain, E. Lyle; Dugas, Jeffrey R.; Andrews, James R.

    2012-01-01

    The activities required during overhead sports, particularly during baseball pitching, produce large forces at the elbow joint. Injuries to the elbow joint frequently occur in the overhead athlete because of the large amount of forces observed during the act of throwing, playing tennis, or playing golf. Injuries may result because of repetitive overuse, leading to tissue failure. Rehabilitation following injury or surgery to the throwing elbow is vital to fully restore normal function and return the athlete to competition as quickly and safely as possible. Rehabilitation of the elbow, whether following injury or postsurgical, must follow a progressive and sequential order, building on the previous phase, to ensure that healing tissues are not compromised. Emphasis is placed on restoring full motion, muscular strength, and neuromuscular control while gradually applying loads to healing tissue. In addition, when one is creating a rehabilitation plan for athletes, it is imperative to treat the entire upper extremity, core, and legs to create and dissipate the forces generated at each joint. PMID:23016113

  20. The Effects of a Functional Elbow Brace on Medial Joint Stability: A Case Study

    PubMed Central

    Pincivero, Danny M.; Rijke, Arie M.; Heinrichs, Kristinn; Perrin, David H.

    1994-01-01

    Medical elbow ligament sprains in athletics can be traumatic and disabling. In this case report, we outline the effect of a prototype functional elbow brace on joint stability in a female collegiate javelin thrower with an ulnar collateral ligament sprain. A valgus force to both elbows was applied using graded stress radiography (Telos GA-II/E stress device) at 0, 5, 10, and 15 kiloPascals (kPa) of pressure. The increase in gap width between the coronoid process and the medial epicondyle was measured from anteroposterior radiographs to determine medial displacement. The brace resulted in less displacement in both injured and noninjured ulnar collateral ligament; injured ulnar collateral ligament demonstrated greater displacement regardless of condition. The brace restored medial stability to the elbow joint by 49%, 38%, and 35% at 5, 10, and 15 kPa of pressure, respectively. The application of the brace may be useful in athletes with ulnar collateral ligament injuries. ImagesFig 1Fig 2 PMID:16558285

  1. Upper limb joint kinetic analysis during tennis serve: Assessment of competitive level on efficiency and injury risks.

    PubMed

    Martin, C; Bideau, B; Ropars, M; Delamarche, P; Kulpa, R

    2014-08-01

    The aim of this work was to compare the joint kinetics and stroke production efficiency for the shoulder, elbow, and wrist during the serve between professionals and advanced tennis players and to discuss their potential relationship with given overuse injuries. Eleven professional and seven advanced tennis players were studied with an optoelectronic motion analysis system while performing serves. Normalized peak kinetic values of the shoulder, elbow, and wrist joints were calculated using inverse dynamics. To measure serve efficiency, all normalized peak kinetic values were divided by ball velocity. t-tests were used to determine significant differences between the resultant joint kinetics and efficiency values in both groups (advanced vs professional). Shoulder inferior force, shoulder anterior force, shoulder horizontal abduction torque, and elbow medial force were significantly higher in advanced players. Professional players were more efficient than advanced players, as they maximize ball velocity with lower joint kinetics. Since advanced players are subjected to higher joint kinetics, the results suggest that they appeared more susceptible to high risk of shoulder and elbow injuries than professionals, especially during the cocking and deceleration phases of the serve. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  2. FE analysis of SMA-based bio-inspired bone-joint system

    NASA Astrophysics Data System (ADS)

    Yang, S.; Seelecke, S.

    2009-10-01

    This paper presents the finite element (FE) analysis of a bio-inspired bone-joint system. Motivated by the BATMAV project, which aims at the development of a micro-air-vehicle platform that implements bat-like flapping flight capabilities, we study the actuation of a typical elbow joint, using shape memory alloy (SMA) in a dual manner. Micro-scale martensitic SMA wires are used as 'metal muscles' to actuate a system of humerus, elbow joint and radius, in concert with austenitic wires, which operate as flexible joints due to their superelastic character. For the FE analysis, the humerus and radius are modeled as standard elastic beams, while the elbow joint and muscle wires use the Achenbach-Muller-Seelecke SMA model as beams and cable elements, respectively. The particular focus of the paper is on the implementation of the above SMA model in COMSOL.

  3. Effects of flexor-pronator muscle loading on valgus stability of the elbow with an intact, stretched, and resected medial ulnar collateral ligament.

    PubMed

    Udall, John H; Fitzpatrick, Michael J; McGarry, Michelle H; Leba, Thu-Ba; Lee, Thay Q

    2009-01-01

    The medial ulnar collateral ligament (MUCL) is an important passive stabilizer to the valgus stresses that athletes experience during overhead throwing motion. However, the role of the flexor-pronator muscles as active stabilizers to valgus stress is not well defined in the literature. The objectives of this study were to quantify the relative contribution of the individual flexor-pronator muscles to valgus stability of the elbow and how this relationship was affected by ligament status. A custom elbow testing system and Microscribe 3DLX were used for biomechanical testing. Flexor-pronator muscles were loaded to simulate contraction, and the valgus angle of the elbow was measured in eight cadaveric specimens at 30 degrees , 60 degrees , and 90 degrees of elbow flexion with 3 different valgus torques applied to the forearm. Loads based on muscle cross-sectional area were applied to the flexor carpi ulnaris (FCU), flexor digitorum superficialis (FDS), and pronator teres (PT). The effect of each muscle was evaluated by unloading the individual muscle while the other 2 remained loaded, resulting in 5 loading conditions: no muscles loaded, all muscles loaded, unloaded FCU, unloaded FDS, and unloaded PT. Valgus angle was measured for 3 MUCL ligament conditions: intact, stretched, and cut. The effect of muscle loading on valgus angle was similar for each ligament condition. Loading the flexor-pronator muscles significantly decreased valgus angle of the elbow in all testing conditions (P < .01). Unloading the FDS significantly increased valgus angle compared to all muscles loaded in all testing conditions (P < .016). Unloading the FCU and PT significantly increased valgus angle in less than half of the testing conditions. The FDS, PT, and FCU are all active stabilizers of the elbow to valgus stress. The FDS is the biggest contributor amongst the flexor-pronator muscles.

  4. A Biomechanical Comparison of the Long Snap in Football Between High School and University Football Players.

    PubMed

    Chizewski, Michael G; Alexander, Marion J L

    2015-08-01

    Limited previous research was located that examined the technique of the long snap in football. The purpose of the study was to compare the joint movements, joint velocities, and body positions used to perform fast and accurate long snaps in high school (HS) and university (UNI) athletes. Ten HS and 10 UNI subjects were recruited for filming, each performing 10 snaps at a target with the fastest and most accurate trial being selected for subject analysis. Eighty-three variables were measured using Dartfish Team Pro 4.5.2 video analysis software, with statistical analysis performed using Microsoft Excel and SPSS 16.0. Several significant comparisons to long snapping technique between groups were noted during analysis; however, the body position and movement variables at release showed the greatest number of significant differences. The UNI athletes demonstrated significantly higher release velocity and left elbow extension velocity, with significantly lower release height and release angle than the HS group. Total snap time (release time + total flight time) was determined to have the strongest correlation to release velocity for the HS group (r = -0.915) and UNI group (r = -0.918). The study suggests HS long snappers may benefit from less elbow flexion and more knee flexion in the backswing (set position) to increase release velocity. University long snappers may benefit from increased left elbow extension range of motion during force production and decreased shoulder flexion at critical instant to increase long snap release velocity.

  5. An upper-limb power-assist exoskeleton using proportional myoelectric control.

    PubMed

    Tang, Zhichuan; Zhang, Kejun; Sun, Shouqian; Gao, Zenggui; Zhang, Lekai; Yang, Zhongliang

    2014-04-10

    We developed an upper-limb power-assist exoskeleton actuated by pneumatic muscles. The exoskeleton included two metal links: a nylon joint, four size-adjustable carbon fiber bracers, a potentiometer and two pneumatic muscles. The proportional myoelectric control method was proposed to control the exoskeleton according to the user's motion intention in real time. With the feature extraction procedure and the classification (back-propagation neural network), an electromyogram (EMG)-angle model was constructed to be used for pattern recognition. Six healthy subjects performed elbow flexion-extension movements under four experimental conditions: (1) holding a 1-kg load, wearing the exoskeleton, but with no actuation and for different periods (2-s, 4-s and 8-s periods); (2) holding a 1-kg load, without wearing the exoskeleton, for a fixed period; (3) holding a 1-kg load, wearing the exoskeleton, but with no actuation, for a fixed period; (4) holding a 1-kg load, wearing the exoskeleton under proportional myoelectric control, for a fixed period. The EMG signals of the biceps brachii, the brachioradialis, the triceps brachii and the anconeus and the angle of the elbow were collected. The control scheme's reliability and power-assist effectiveness were evaluated in the experiments. The results indicated that the exoskeleton could be controlled by the user's motion intention in real time and that it was useful for augmenting arm performance with neurological signal control, which could be applied to assist in elbow rehabilitation after neurological injury.

  6. MR imaging of patients with lateral epicondylitis of the elbow: is the common extensor tendon an isolated lesion?

    PubMed

    Qi, Liang; Zhu, Zheng-Feng; Li, Feng; Wang, Ren-Fa

    2013-01-01

    To investigate whether an injury of the common extensor tendon (CET) is associated with other abnormalities in the elbow joint and find the potential relationships between these imaging features by using a high-resolution magnetic resonance imaging (MRI). Twenty-three patients were examined with 3.0 T MR. Two reviewers were recruited for MR images evaluation. Image features were recorded in terms of (1) the injury degree of CET; (2) associated injuries in the elbow joint. Spearman's rank correlation analysis was performed to analyze the relationships between the injury degree of CET and associated abnormalities of the elbow joint, correlations were considered significant at p<0.05. Total 24 elbows in 23 patients were included. Various degrees of injuries were found in total 24 CETs (10 mild, 7 moderate and 7 severe). Associated abnormalities were detected in accompaniments of the elbow joints including ligaments, tendons, saccussynovialis and muscles. A significantly positive correlation (r = 0.877,p<0.01) was found in injuries of CET and lateral ulnar collateral ligament (LUCL). Injury of the CET is not an isolated lesion for lateral picondylitis, which is mostly accompanied with other abnormalities, of which the LUCL injury is the most commonly seen in lateral epicondylitis, and there is a positive correlation between the injury degree in CET and LUCL.

  7. Dry Arthroscopy of the Elbow.

    PubMed

    Phadnis, Joideep; Bain, Gregory

    2015-08-01

    Dry arthroscopy is attractive because it affords an unsurpassed clarity of view and minimizes swelling. The elbow is a challenging joint to assess arthroscopically; however, dry arthroscopy has some particular benefits in the elbow. The primary benefit is the quality of the tissue definition, but dry arthroscopy also increases the working time for surgery by reducing swelling and results in less postoperative discomfort for the patient. With dry arthroscopy, all joint surfaces are covered in synovial fluid, which reflects light, to provide a clearer image of the joint surfaces and depth of field. The air-fluid interface provides an uninterrupted appreciation of the synovial recesses and tissue perfusion. This article describes the technique and indications for dry elbow arthroscopy, which will allow other surgeons to reap the benefits of dry arthroscopy without the need for special equipment or changes in their basic technique.

  8. Dry Arthroscopy of the Elbow

    PubMed Central

    Phadnis, Joideep; Bain, Gregory

    2015-01-01

    Dry arthroscopy is attractive because it affords an unsurpassed clarity of view and minimizes swelling. The elbow is a challenging joint to assess arthroscopically; however, dry arthroscopy has some particular benefits in the elbow. The primary benefit is the quality of the tissue definition, but dry arthroscopy also increases the working time for surgery by reducing swelling and results in less postoperative discomfort for the patient. With dry arthroscopy, all joint surfaces are covered in synovial fluid, which reflects light, to provide a clearer image of the joint surfaces and depth of field. The air-fluid interface provides an uninterrupted appreciation of the synovial recesses and tissue perfusion. This article describes the technique and indications for dry elbow arthroscopy, which will allow other surgeons to reap the benefits of dry arthroscopy without the need for special equipment or changes in their basic technique. PMID:26759772

  9. Treatment of elbow osteomyelitis with an interposition arthroplasty using a rectus abdominis free flap.

    PubMed

    Jaiswal, Rohit; Busse, Brittany; Allen, Robert; Sahar, David

    2015-05-01

    Osteomyelitis of the elbow may be a complex clinical problem. Treatment goals include the eradication of infection and preservation of maximal joint function. Bony debridement may be necessary in addition to elbow joint arthroplasty. The use of synthetic material or allograft as the arthroplasty material may be contraindicated in the setting of infection. The use of free muscle transfer as an arthroplasty medium has not been well described. A 22-year-old paraplegic man developed recurrent osteomyelitis of the right elbow, necessitating extensive bony debridement by the orthopedic surgery team. Reconstruction arthroplasty was performed using a free rectus abdominis muscle flap as the arthroplasty material to serve as a source of biologically active, well-vascularized arthroplasty medium in the presence of ongoing infection. A successful free muscle flap arthroplasty was performed. External fixation and physical therapy were implemented postoperatively. The patient had resolution of osteomyelitis and excellent functional use of the elbow for activities of daily living and wheelchair motion. Elbow arthroplasty in the setting of active infection may be accomplished by means of free tissue muscle transfer. Elimination of infection and acceptable joint function may be possible with this form of reconstruction.

  10. Pronation-Supination Motion Is Altered in a Rat Model of Post-Traumatic Elbow Contracture.

    PubMed

    Dunham, Chelsey L; Castile, Ryan M; Chamberlain, Aaron M; Galatz, Leesa M; Lake, Spencer P

    2017-07-01

    The elbow joint is highly susceptible to joint contracture, and treating elbow contracture is a challenging clinical problem. Previously, we established an animal model to study elbow contracture that exhibited features similar to the human condition including persistent decreased range of motion (ROM) in flexion-extension and increased capsule thickness/adhesions. The objective of this study was to mechanically quantify pronation-supination in different injury models to determine if significant differences compared to control or contralateral persist long-term in our animal elbow contracture model. After surgically inducing soft tissue damage in the elbow, Injury I (anterior capsulotomy) and Injury II (anterior capsulotomy with lateral collateral ligament transection), limbs were immobilized for 6 weeks (immobilization (IM)). Animals were evaluated after the IM period or following an additional 6 weeks of free mobilization (FM). Total ROM for pronation-supination was significantly decreased compared to the uninjured contralateral limb for both IM and FM, although not different from control limbs. Specifically, for both IM and FM, total ROM for Injury I and Injury II was significantly decreased by ∼20% compared to contralateral. Correlations of measurements from flexion-extension and pronation-supination divulged that FM did not affect these motions in the same way, demonstrating that joint motions need to be studied/treated separately. Overall, injured limbs exhibited persistent motion loss in pronation-supination when comparing side-to-side differences, similar to human post-traumatic joint contracture. Future work will use this animal model to study how elbow periarticular soft tissues contribute to contracture.

  11. Effects of simulated lightning on composite and metallic joints

    NASA Technical Reports Server (NTRS)

    Howell, W. E.; Plumer, J. A.

    1982-01-01

    The effects of simulated lightning strikes and currents on aircraft bonded joints and access/inspection panels were investigated. Both metallic and composite specimens were tested. Tests on metal fuel feed through elbows in graphite/epoxy structures were evaluated. Sparking threshold and residual strength of single lap bonded joints and sparking threshold of access/inspection panels and metal fuel feed through elbows are reported.

  12. Development Requirements for Spacesuit Elbow Joint

    NASA Technical Reports Server (NTRS)

    Peters, Benjamin

    2017-01-01

    Functional Requirements for spacesuit elbow joint:1) The system is a conformal, single-axis spacesuit pressurized joint that encloses the elbow joint of the suited user and uses a defined interface to connect to the suit systems on either side of the joint.2) The system shall be designed to bear the loads incurred from the internal pressure of the system, as well as the expected loads induced by the user while enabling the user move the joint through the required range of motion. The joint torque of the system experienced by the user shall remain at or below the required specification for the entire range of motion.3) The design shall be constructed, at a minimum, as a two-layer system. The internal, air-tight layer shall be referred to as the bladder, and the layer on the unpressurized side of the bladder shall be referred to as the restraint. The design of the system may include additional features or layers, such as axial webbing, to meet the overall requirements of the design.

  13. Intra-Articular Entrapment of the Medial Epicondyle following a Traumatic Fracture Dislocation of the Elbow in an Adult

    PubMed Central

    Hassan, Youssef G.; Joukhadar, Nabih I.

    2018-01-01

    Medial epicondyle entrapment after an acute fracture dislocation of the elbow is a common finding in the pediatric population, but a rare finding in adults. We present a case of an adult patient diagnosed with a traumatic fracture dislocation of the elbow joint with intra-articular entrapment of the medial epicondyle. After initial evaluation, closed reduction was done. Stability testing after reduction showed an unstable joint; thus, open reduction and internal fixation was decided. PMID:29666736

  14. Characterization of posture and comfort in laptop users in non-desk settings.

    PubMed

    Gold, J E; Driban, J B; Yingling, V R; Komaroff, E

    2012-03-01

    Laptop computers may be used in a variety of postures not coupled to the office workstation. Using passive motion analysis, this study examined mean joint angles during a short typing/editing task in college students (n=20), in up to seven positions. Comfort was assessed after task execution through a body map. For three required postures, joint angles in a prone posture were different than those while seated at a couch with feet either on floor or on ottoman. Specifically, the prone posture was characterized by comparatively non-neutral shoulders, elbows and wrists, and pronounced neck extension. Significantly greater intensity and more regions of discomfort were marked for the prone posture than for the seated postures. It is recommended that the prone posture only be assumed briefly during laptop use. Exposure to laptops outside of the office setting should be assessed in future epidemiologic studies of musculoskeletal complaints and computer use. Copyright © 2011 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  15. Neuromuscular interfacing: establishing an EMG-driven model for the human elbow joint.

    PubMed

    Pau, James W L; Xie, Shane S Q; Pullan, Andrew J

    2012-09-01

    Assistive devices aim to mitigate the effects of physical disability by aiding users to move their limbs or by rehabilitating through therapy. These devices are commonly embodied by robotic or exoskeletal systems that are still in development and use the electromyographic (EMG) signal to determine user intent. Not much focus has been placed on developing a neuromuscular interface (NI) that solely relies on the EMG signal, and does not require modifications to the end user's state to enhance the signal (such as adding weights). This paper presents the development of a flexible, physiological model for the elbow joint that is leading toward the implementation of an NI, which predicts joint motion from EMG signals for both able-bodied and less-abled users. The approach uses musculotendon models to determine muscle contraction forces, a proposed musculoskeletal model to determine total joint torque, and a kinematic model to determine joint rotational kinematics. After a sensitivity analysis and tuning using genetic algorithms, subject trials yielded an average root-mean-square error of 6.53° and 22.4° for a single cycle and random cycles of movement of the elbow joint, respectively. This helps us to validate the elbow model and paves the way toward the development of an NI.

  16. ELBOW AND WRIST INJURIES IN SPORTS

    PubMed Central

    Marmor, Leonard; Bechtol, Charles O.

    1960-01-01

    Any disabling injury of the elbow or wrist should be studied roentgenographically for evidence of fracture which may not be otherwise evident but which may cause permanent disability unless the joint is immobilized for healing. “Tennis elbow” may be treated with physical therapy and analgesic injection but may require splinting or tendon stripping. Elbow sprain can occur in the growing epiphysis but is rare in adults. A jarring fall on the hand may cause fracture or dislocation at the elbow. Full extension of the joint should be restored gradually by active exercise rather than passive or forcible stretching. Fracture at the head of the radius may cause joint hemorrhage with severe pain which can be relieved by aspiration. A displacing fracture at the head of the radius requires removal of the head to prevent arthritic changes. Myositis ossificans contraindicates operation until after it has cleared. Healing of wrist fractures may be facilitated by exercise of the shoulder and elbow while the wrist is still in a cast. Fractures of the navicular bone are difficult to detect even roentgenographically and splinting may have to be done on clinical evidence alone. PMID:14421374

  17. Relationship between Joint Position Sense, Force Sense, and Muscle Strength and the Impact of Gymnastic Training on Proprioception

    PubMed Central

    Kochanowicz, Andrzej

    2018-01-01

    The aims of this study were (1) to assess the relationship between joint position (JPS) and force sense (FS) and muscle strength (MS) and (2) to evaluate the impact of long-term gymnastic training on particular proprioception aspects and their correlations. 17 elite adult gymnasts and 24 untrained, matched controls performed an active reproduction (AR) and passive reproduction (PR) task and a force reproduction (FR) task at the elbow joint. Intergroup differences and the relationship between JPS, FS, and MS were evaluated. While there was no difference in AR or PR between groups, absolute error in the control group was higher during the PR task (7.15 ± 2.72°) than during the AR task (3.1 ± 1.93°). Mean relative error in the control group was 61% higher in the elbow extensors than in the elbow flexors during 50% FR, while the gymnast group had similar results in both reciprocal muscles. There was no linear correlation between JPS and FS in either group; however, FR was negatively correlated with antagonist MS. In conclusion, this study found no evidence for a relationship between the accuracy of FS and JPS at the elbow joint. Long-term gymnastic training improves the JPS and FS of the elbow extensors. PMID:29670901

  18. Prosthetic elbow joint

    NASA Technical Reports Server (NTRS)

    Weddendorf, Bruce C. (Inventor)

    1994-01-01

    An artificial, manually positionable elbow joint for use in an upper extremity, above-elbow, prosthetic is described. The prosthesis provides a locking feature that is easily controlled by the wearer. The instant elbow joint is very strong and durable enough to withstand the repeated heavy loadings encountered by a wearer who works in an industrial, construction, farming, or similar environment. The elbow joint of the present invention comprises a turntable, a frame, a forearm, and a locking assembly. The frame generally includes a housing for the locking assembly and two protruding ears. The forearm includes an elongated beam having a cup-shaped cylindrical member at one end and a locking wheel having a plurality of holes along a circular arc on its other end with a central bore for pivotal attachment to the protruding ears of the frame. The locking assembly includes a collar having a central opening with a plurality of internal grooves, a plurality of internal cam members each having a chamfered surface at one end and a V-shaped slot at its other end; an elongated locking pin having a crown wheel with cam surfaces and locking lugs secured thereto; two coiled compression springs; and a flexible filament attached to one end of the elongated locking pin and extending from the locking assembly for extending and retracting the locking pin into the holes in the locking wheel to permit selective adjustment of the forearm relative to the frame. In use, the turntable is affixed to the upper arm part of the prosthetic in the conventional manner, and the cup-shaped cylindrical member on one end of the forearm is affixed to the forearm piece of the prosthetic in the conventional manner. The elbow joint is easily adjusted and locked between maximum flex and extended positions.

  19. Series elastic actuation of an elbow rehabilitation exoskeleton with axis misalignment adaptation.

    PubMed

    Wu, Kuan-Yi; Su, Yin-Yu; Yu, Ying-Lung; Lin, Kuei-You; Lan, Chao-Chieh

    2017-07-01

    Powered exoskeletons can facilitate rehabilitation of patients with upper limb disabilities. Designs using rotary motors usually result in bulky exoskeletons to reduce the problem of moving inertia. This paper presents a new linearly actuated elbow exoskeleton that consists of a slider crank mechanism and a linear motor. The linear motor is placed beside the upper arm and closer to shoulder joint. Thus better inertia properties can be achieved while lightweight and compactness are maintained. A passive joint is introduced to compensate for the exoskeleton-elbow misalignment and intersubject size variation. A linear series elastic actuator (SEA) is proposed to obtain accurate force and impedance control at the exoskeleton-elbow interface. Bidirectional actuation between exoskeleton and forearm is verified, which is required for various rehabilitation processes. We expect this exoskeleton can provide a means of robot-aided elbow rehabilitation.

  20. Mechanically Evoked Torque and Electromyographic Responses During Passive Elbow Extension in Upper Limb Tension Test Position

    DTIC Science & Technology

    2001-10-25

    axis during passive elbow extension. A padded shoulder block was placed superior to the subject’s acromioclavicular joint to stabilize the shoulder...girdle position. A pressure sensor was used between the padded shoulder block and the acromioclavicular joint to monitor and standardize the pressure

  1. The ergonomics of laparoscopic surgery: a quantitative study of the time and motion of laparoscopic surgeons in live surgical environments.

    PubMed

    Aitchison, Lucy Ping; Cui, Cathy Kexin; Arnold, Amy; Nesbitt-Hawes, Erin; Abbott, Jason

    2016-11-01

    Laparoscopic surgery presents multiple ergonomic difficulties for the surgeon, requiring awkward body postures and prolonged static muscle loading that increases risk of musculoskeletal strain and injury. This prospective study quantitatively measures the biomechanical movements of surgeons during laparoscopic procedures to determine at-risk movements from prolonged static muscle loading and repetitive motions that may lead to injury. A total of 150 video recordings of 18 surgeons, standing at the patient's left, were captured from three fixed camera positions during live gynecological laparoscopic surgery. Postoperative processing quantified surgeon movements at the neck, shoulders and elbows using computer software to measure extreme joint angles and time spent within defined joint angle ranges. Surgeons spent a median of 98 % (range 77-100 %) of surgical time with their neck rotated at 21° (range 0°-52°). The non-dominant arm was subjected to more extreme positions for significantly longer periods of time compared to the dominant, with shoulder flexion at 45°-90° for 35 vs. 0 % (p < 0.001) and elbow flexion at >120° for 31 vs. 0 % (p < 0.001) of total surgical time. Procedures involving power morcellation required significantly greater number of instrument insertion/removals-119 (range 56-182) compared with 12 (range 2-122) when morcellation was not used (p < 0.001). Shorter surgeons maintained significantly greater degrees of neck rotation when viewing the monitor (p < 0.003) and surgeons with shorter arm lengths spent longer in extreme positions with their non-dominant shoulder at >90° (p = 0.04) and elbow at >120° (p < 0.001) compared with taller surgeons. No significant correlations were found between BMI or surgical experience and more extreme joint positions. Four primary areas have been identified where surgeons are consistently demonstrating movements that increase their risk of harm: (1) extended periods of neck rotation; (2) asymmetrical loading between the dominant and non-dominant shoulders; (3) power morcellation and frequent insertions/removals of laparoscopic instruments resulting in repetitions of the most extreme shoulder positions and (4) a negative correlation between height and percentage time spent in more extreme positions.

  2. Visualization of 3D elbow kinematics using reconstructed bony surfaces

    NASA Astrophysics Data System (ADS)

    Lalone, Emily A.; McDonald, Colin P.; Ferreira, Louis M.; Peters, Terry M.; King, Graham J. W.; Johnson, James A.

    2010-02-01

    An approach for direct visualization of continuous three-dimensional elbow kinematics using reconstructed surfaces has been developed. Simulation of valgus motion was achieved in five cadaveric specimens using an upper arm simulator. Direct visualization of the motion of the ulna and humerus at the ulnohumeral joint was obtained using a contact based registration technique. Employing fiducial markers, the rendered humerus and ulna were positioned according to the simulated motion. The specific aim of this study was to investigate the effect of radial head arthroplasty on restoring elbow joint stability after radial head excision. The position of the ulna and humerus was visualized for the intact elbow and following radial head excision and replacement. Visualization of the registered humerus/ulna indicated an increase in valgus angulation of the ulna with respect to the humerus after radial head excision. This increase in valgus angulation was restored to that of an elbow with a native radial head following radial head arthroplasty. These findings were consistent with previous studies investigating elbow joint stability following radial head excision and arthroplasty. The current technique was able to visualize a change in ulnar position in a single DoF. Using this approach, the coupled motion of ulna undergoing motion in all 6 degrees-of-freedom can also be visualized.

  3. Assessment of medial coronoid disease in 180 canine lame elbow joints: a sensitivity and specificity comparison of radiographic, computed tomographic and arthroscopic findings.

    PubMed

    Villamonte-Chevalier, A; van Bree, H; Broeckx, Bjg; Dingemanse, W; Soler, M; Van Ryssen, B; Gielen, I

    2015-09-25

    Diagnostic imaging is essential to assess the lame patient; lesions of the elbow joint have traditionally been evaluated radiographically, however computed tomography (CT) has been suggested as a useful technique to diagnose various elbow pathologies. The primary objective of this study was to determine the sensitivity and specificity of CT to assess medial coronoid disease (MCD), using arthroscopy as gold standard. The secondary objective was to ascertain the radiographic sensitivity and specificity for MCD compared with CT. For this study 180 elbow joints were assessed, of which 141 had been examined with radiography, CT and arthroscopy; and 39 joints, had radiographic and CT assessment. Sensitivity and specificity were calculated for CT and radiographic findings using available statistical software. Sensitivity and specificity of CT using arthroscopy as gold standard resulted in high values for sensitivity (100 %) and specificity (93 %) for the assessment of MCD. For the radiographic evaluation, a sensitivity of 98 % and specificity of 64 - 69 % using CT as the technique of reference, were found. These results suggest that in case of doubt during radiographic assessment, CT could be used as a non-invasive technique to assess the presence of MCD. Based on the high sensitivity and specificity obtained in this study it has been considered that CT, rather than arthroscopy, is the preferred noninvasive technique to assess MCD lesions of the canine elbow joint.

  4. Phase-dependence of elbow muscle coactivation in front crawl swimming.

    PubMed

    Lauer, Jessy; Figueiredo, Pedro; Vilas-Boas, João Paulo; Fernandes, Ricardo J; Rouard, Annie Hélène

    2013-08-01

    Propulsion in swimming is achieved by complex sculling movements with elbow quasi-fixed on the antero-posterior axis to transmit forces from the hand and the forearm to the body. The purpose of this study was to investigate how elbow muscle coactivation was influenced by the front crawl stroke phases. Ten international level male swimmers performed a 200-m front crawl race-pace bout. Sagittal views were digitized frame by frame to determine the stroke phases (aquatic elbow flexion and extension, aerial elbow flexion and extension). Surface electromyograms (EMG) of the right biceps brachii and triceps brachii were recorded and processed using the integrated EMG to calculate a coactivation index (CI) for each phase. A significant effect of the phases on the CI was revealed with highest levels of coactivation during the aquatic elbow flexion and the aerial elbow extension. Swimmers stabilize the elbow joint to overcome drag during the aquatic phase, and act as a brake at the end of the recovery to replace the arm for the next stroke. The CI can provide insight into the magnitude of mechanical constraints supported by a given joint, in particular during a complex movement. Copyright © 2013 Elsevier Ltd. All rights reserved.

  5. Physical Risk Factors for a Medial Elbow Injury in Junior Baseball Players: A Prospective Cohort Study of 353 Players.

    PubMed

    Sakata, Jun; Nakamura, Emi; Suzukawa, Makoto; Akaike, Atsushi; Shimizu, Kuniaki

    2017-01-01

    The physical risk factors for a medial elbow injury in junior baseball players are unknown. To identify the risk factors for an initial medial elbow injury in junior baseball players. Case-control study; Level of evidence, 3. Junior baseball players (aged 6-12 years) without a history of elbow pain underwent a clinical assessment, ultrasonography, and physical function measurements before the baseball season started. Bilateral passive range of motion (ROM) of elbow extension and flexion, external rotation (ER) and internal rotation (IR) of the shoulder, and ER and IR of the hip were measured. IR and ER strength of the shoulder and scapular muscles were measured on both sides. The thoracic kyphosis angle was measured with participants in a relaxed standing position. Before these examinations, every participant completed a questionnaire regarding his or her age, sex, total years of baseball played, position in baseball, number of balls thrown, and episodes of pain during throwing. After the initial test session, each participant was followed up for 12 months to assess for the occurrence of a new injury. Multiple regression analysis was used to identify the risk factors for a medial elbow injury. Seventy-eight players (22.1%) sustained a medial elbow injury. Age ≥9 years (odds ratio [OR], 2.708; 95% CI, 1.224-5.990), pitcher position (OR, 2.620; 95% CI, 1.389-4.941), >100 throws per day (OR, 1.936; 95% CI, 1.072-3.497), thoracic kyphosis angle ≥30° (OR, 2.501; 95% CI, 1.381-4.531), and elbow extension deficit ≥5° (OR, 1.973; 95% CI, 1.022-3.809) were significantly associated with a medial elbow injury. The incidence of an initial medial elbow injury was 22.1%. Age, number of throws per day, thoracic kyphosis angle, and elbow extension deficit are newly discovered risk factors related to physical function. Improvement of the posture and early detection of a silent elbow extension deficit may prevent a medial elbow injury.

  6. Analysis of the 5 iron golf swing when hitting for maximum distance.

    PubMed

    Healy, Aoife; Moran, Kieran A; Dickson, Jane; Hurley, Cillian; Smeaton, Alan F; O'Connor, Noel E; Kelly, Philip; Haahr, Mads; Chockalingam, Nachiappan

    2011-07-01

    Most previous research on golf swing mechanics has focused on the driver club. The aim of this study was to identify the kinematic factors that contribute to greater hitting distance when using the 5 iron club. Three-dimensional marker coordinate data were collected (250 Hz) to calculate joint kinematics at eight key swing events, while a swing analyser measured club swing and ball launch characteristics. Thirty male participants were assigned to one of two groups, based on their ball launch speed (high: 52.9 ± 2.1 m · s(-1); low: 39.9 ± 5.2 m · s(-1)). Statistical analyses were used to identify variables that differed significantly between the two groups. Results showed significant differences were evident between the two groups for club face impact point and a number of joint angles and angular velocities, with greater shoulder flexion and less left shoulder internal rotation in the backswing, greater extension angular velocity in both shoulders at early downswing, greater left shoulder adduction angular velocity at ball contact, greater hip joint movement and X Factor angle during the downswing, and greater left elbow extension early in the downswing appearing to contribute to greater hitting distance with the 5 iron club.

  7. Immediate Biomechanical Implications of Transfer Component Skills Training on Independent Wheelchair Transfers.

    PubMed

    Tsai, Chung-Ying; Boninger, Michael L; Hastings, Jennifer; Cooper, Rory A; Rice, Laura; Koontz, Alicia M

    2016-10-01

    To evaluate the immediate effects of transfer training based on the Transfer Assessment Instrument (TAI) on the upper limb biomechanics during transfers. Pre-post intervention. Biomechanics laboratory. Full-time manual wheelchair users (N=24) performed 5 transfers to a level height bench, while their natural transfer skills were scored using the TAI, and their biomechanical data were recorded. Participants with 2 or more component skill deficits were invited to return to receive personalized transfer training. TAI part 1 summary scores and biomechanical variables calculated at the shoulder, elbow, and wrist joints were compared before and immediately after transfer training. Sixteen of the 24 manual wheelchair users met the criteria for training, and 11 manual wheelchair users came back for the revisit. Their TAI part 1 summary scores improved from 6.31±.98 to 9.92±.25. They had significantly smaller elbow range of motion, shoulder resultant moment, and rates of rise of elbow and wrist resultant forces on their trailing side during transfers after training (P<.05). On the leading side, shoulder maximum internal rotation and elevation angles, and shoulder resultant moments and rates of rise of shoulder resultant force and moment decreased after training (P<.04). The TAI-based training showed short-term beneficial biomechanical effects on wheelchair users' upper limbs, such as better shoulder positioning and lower joint loadings. If the skills are practiced longer-term, they may help protect the upper limbs from developing pain and injuries. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  8. Physical examination of the athlete's elbow.

    PubMed

    Hsu, Stephanie H; Moen, Todd C; Levine, William N; Ahmad, Christopher S

    2012-03-01

    Elbow injury is encountered less frequently than are other joint conditions. The bony architecture, muscle, ligament, and nerve anatomy are complex, and the forces leading to injury in the athlete's elbow are unique. Appreciating the pathomechanics leading to injury and a detailed knowledge of elbow anatomy are the foundation for conducting a directed history and physical examination that achieves an accurate diagnosis. Recent advances in physical examination have improved our ability to accurately diagnose and treat athletic elbow disorders. This article reviews general and focused physical examination maneuvers of the elbow in a systematic anatomic fashion.

  9. Torso and Bowing Arm Three-Dimensional Joint Kinematics of Elite Cellists: Clinical and Pedagogical Implications for Practice.

    PubMed

    Hopper, Luke; Chan, Cliffton; Wijsman, Suzanne; Ackland, Timothy; Visentin, Peter; Alderson, Jacqueline

    2017-06-01

    Elite cello playing requires complex and refined motor control. Cellists are prone to right shoulder and thoracolumbar injuries. Research informing injury management of cellists and cello pedagogy is limited. The aims of this study were to quantify the torso, right shoulder, and elbow joint movement used by elite cellists while performing a fundamental playing task, a C major scale, under two volume conditions. An eight degrees of freedom upper limb biomechanical model was applied to 3D motion capture data of the torso, upper arm, and forearm for 31 cellists with a mean experience of 19.4 yrs (SD 9.1). Two-factor ANOVA compared the joint positions between the four cello strings and two volume conditions. Significant (p<0.05) effects were found for either the string and/or volume conditions across all torso, shoulder, and elbow joint degrees of freedom. The torso was consistently positioned in left rotation from 5.0° (SD 5.6) at the beginning of the scale, increasing to 16.3° (5.5) at its apogee. The greatest mean shoulder flexion, internal rotation, and abduction joint angles were observed when playing at the tip of the bow on the top string (A): 107.2° (11.6), 59.1° (7.1), and -76.9° (15.7), respectively, during loud playing. Elite cellists use specific movement patterns to achieve string crossings and volume regulation during fundamental playing tasks. Implications of the static left-rotated torso posture and high degrees of combined shoulder flexion and internal rotation can be used to inform clinical and pedagogical practices.

  10. Management of tennis elbow by Agnikarma.

    PubMed

    Mahanta, Vyasadeva; Dudhamal, Tukaram S; Gupta, Sanjay Kumar

    2013-01-01

    Tennis elbow is a painful condition and causes restricted movement of forearm which requires treatment for long period. Till date only symptomatic treatments are available like use of anti-inflammatory analgesic drugs, steroids injection, physiotherapy, exercise etc. But none of these provide satisfactory result. Long term use of anti-inflammatory, analgesic drugs and steroids injection is also not free from the adverse effects. Usually, 'wait-and-see policy' of treatment guideline is recommended in most of medical texts. According to Ayurveda, snayugata vata can be correlated with the condition of tennis elbow. Sushruta has advised Agnikarma for disorders of snayu (ligaments and tendons), asthi (bone), siddhi (joints) etc. Hence, in this study a case of tennis elbow (snayugata vata) was treated by Agnikarma, along with administration of powder of Ashwagandha and Navajivana Rasa orally, for a period of 03 weeks. This combination therapy provided considerable relief in pain and movement of the elbow joint.

  11. Risk of nerve injury during arthroscopy portal placement in the elbow joint: A cadaveric study

    PubMed Central

    Chaware, Prashant N; Santoshi, John A; Pakhare, Abhijit P; Rathinam, Bertha A D

    2016-01-01

    Background: Elbow arthroscopy has become a routine procedure now. However, placing portals is fraught with dangers of injuring the neurovascular structures around elbow. There are not enough data documenting the same amongst the Indians. We aimed to determine the relative distances of nerves around the elbow to the arthroscopy portals and risk of injury in different positions of the elbow. Materials and Methods: Six standard elbow arthroscopy portals were established in 12 cadaveric upper limbs after joint distension. Then using standard dissection techniques all the nerves around the elbow were exposed, and their distances from relevant portals were measured using digital vernier caliper in 90° elbow flexion and 0° extension. Descriptive statistical analysis was used for describing distance of the nerves from relevant portal. Wilcoxon-signed rank test and Friedman's test were used for comparison. Results: There was no major nerve injury at all the portals studied in both positions of the elbow. The total incidence of cutaneous nerve injury was 8.3% (12/144); medial cutaneous nerve of forearm 10/48 and posterior cutaneous nerve of forearm 2/24. No significant changes were observed in the distance of a nerve to an individual portal at 90° flexion or 0° extension position of the elbow. Conclusion: This study demonstrates the risk of injury to different nerves at the standard portals of elbow arthroscopy. In practice, the actual incidence of nerve injury may still be lower. We conclude that elbow arthroscopy is a safe procedure when all precautions as described are duly followed. PMID:26952128

  12. Experience of Soviet Medicine in a Great Patriotic War, 1941-1945. Volume 16, Section 4.

    DTIC Science & Technology

    1980-10-22

    Rotor function in the elbow, wrist joint and in the fingers/pins. In spite of energetic treatment by physiotherapy and therapeutic gymnastics , remained...the radiocarpal and elbow joint is removed by therapeutic gymnastics . It is discharged after 84 days (4/11 1943) with a good anatomical and functional...military service, it returned home into Moscow. on the arrival into nosco knee joint did not fold. Injured person itself dealt by gymnastics and in a

  13. Corticomotor excitability of arm muscles modulates according to static position and orientation of the upper limb.

    PubMed

    Mogk, Jeremy P M; Rogers, Lynn M; Murray, Wendy M; Perreault, Eric J; Stinear, James W

    2014-10-01

    We investigated how multi-joint changes in static upper limb posture impact the corticomotor excitability of the posterior deltoid (PD) and biceps brachii (BIC), and evaluated whether postural variations in excitability related directly to changes in target muscle length. The amplitude of individual motor evoked potentials (MEPs) was evaluated in each of thirteen different static postures. Four functional postures were investigated that varied in shoulder and elbow angle, while the forearm was positioned in each of three orientations. Posture-related changes in muscle lengths were assessed using a biomechanical arm model. Additionally, M-waves were evoked in the BIC in each of three forearm orientations to assess the impact of posture on recorded signal characteristics. BIC-MEP amplitudes were altered by shoulder and elbow posture, and demonstrated robust changes according to forearm orientation. Observed changes in BIC-MEP amplitudes exceeded those of the M-waves. PD-MEP amplitudes changed predominantly with shoulder posture, but were not completely independent of influence from forearm orientation. Results provide evidence that overall corticomotor excitability can be modulated according to multi-joint upper limb posture. The ability to alter motor pathway excitability using static limb posture suggests the importance of posture selection during rehabilitation aimed at retraining individual muscle recruitment and/or overall coordination patterns. Published by Elsevier Ireland Ltd.

  14. Quantification and visualization of coordination during non-cyclic upper extremity motion.

    PubMed

    Fineman, Richard A; Stirling, Leia A

    2017-10-03

    There are many design challenges in creating at-home tele-monitoring systems that enable quantification and visualization of complex biomechanical behavior. One such challenge is robustly quantifying joint coordination in a way that is intuitive and supports clinical decision-making. This work defines a new measure of coordination called the relative coordination metric (RCM) and its accompanying normalization schemes. RCM enables quantification of coordination during non-constrained discrete motions. Here RCM is applied to a grasping task. Fifteen healthy participants performed a reach, grasp, transport, and release task with a cup and a pen. The measured joint angles were then time-normalized and the RCM time-series were calculated between the shoulder-elbow, shoulder-wrist, and elbow-wrist. RCM was normalized using four differing criteria: the selected joint degree of freedom, angular velocity, angular magnitude, and range of motion. Percent time spent in specified RCM ranges was used asa composite metric and was evaluated for each trial. RCM was found to vary based on: (1) chosen normalization scheme, (2) the stage within the task, (3) the object grasped, and (4) the trajectory of the motion. The RCM addresses some of the limitations of current measures of coordination because it is applicable to discrete motions, does not rely on cyclic repetition, and uses velocity-based measures. Future work will explore clinically relevant differences in the RCM as it is expanded to evaluate different tasks and patient populations. Copyright © 2017. Published by Elsevier Ltd.

  15. [Endoprostheses in geriatric traumatology].

    PubMed

    Buecking, B; Eschbach, D; Bliemel, C; Knobe, M; Aigner, R; Ruchholtz, S

    2017-01-01

    Geriatric traumatology is increasing in importance due to the demographic transition. In cases of fractures close to large joints it is questionable whether primary joint replacement is advantageous compared to joint-preserving internal fixation. The aim of this study was to describe the importance of prosthetic joint replacement in the treatment of geriatric patients suffering from frequent periarticular fractures in comparison to osteosynthetic joint reconstruction and conservative methods. A selective search of the literature was carried out to identify studies and recommendations concerned with primary arthroplasty of fractures in the region of the various joints (hip, shoulder, elbow and knee). The importance of primary arthroplasty in geriatric traumatology differs greatly between the various joints. Implantation of a prosthesis has now become the gold standard for displaced fractures of the femoral neck. In addition, reverse shoulder arthroplasty has become an established alternative option to osteosynthesis in the treatment of complex proximal humeral fractures. Due to a lack of large studies definitive recommendations cannot yet be given for fractures around the elbow and the knee. Nowadays, joint replacement for these fractures is recommended only if reconstruction of the joint surface is not possible. The importance of primary joint replacement for geriatric fractures will probably increase in the future. Further studies with larger patient numbers must be conducted to achieve more confidence in decision making between joint replacement and internal fixation especially for shoulder, elbow and knee joints.

  16. Factors Related to Increased Ulnar Collateral Ligament Thickness on Stress Sonography of the Elbow in Asymptomatic Youth and Adolescent Baseball Pitchers.

    PubMed

    Atanda, Alfred; Averill, Lauren W; Wallace, Maegen; Niiler, Tim A; Nazarian, Levon N; Ciccotti, Michael G

    2016-12-01

    Stress ultrasound (SUS) of the elbow has demonstrated changes in the anterior band of the ulnar collateral ligament (UCL) in professional and high school-aged pitchers. However, there have been no large reports correlating pitching history data with SUS changes in youth and adolescent baseball pitchers. Changes of the UCL on SUS will correlate with pitching volume in youth and adolescent baseball pitchers. Cross-sectional study; Level of evidence, 3. SUS of the elbow was performed in both elbows of 102 youth and adolescent baseball pitchers. UCL thickness and the width of the ulnohumeral joint, at rest and with 150 N of valgus stress, were measured using a standardized, instrumented device. Demographic data, arm measurements, and a pitching history questionnaire were recorded as well. The pitchers were separated into 2 groups based on age: group 1 (12-14 years) and group 2 (15-18 years). SUS findings of the dominant elbows were compared between the 2 groups. Correlation analysis and linear regression were used to identify relationships between SUS findings and pitching history data. In all pitchers, the mean UCL thickness was 4.40 mm in the dominant elbow and 4.11 mm in the nondominant elbow (P =.03). There was no significant difference between elbows in any joint space characteristics. A comparison of group 1 versus group 2 demonstrated significant differences in UCL thickness (4.13 vs 4.96 mm; P < .001), resting joint space width (6.56 vs 4.04 mm; P < .001), and stressed joint space width (7.68 vs 4.07 mm; P < .001). There was no difference in the change in joint space width between the 2 groups (1.11 vs 0.76 mm; P = .05). The UCL was significantly thicker in pitchers who threw more than 67 pitches per appearance (4.69 vs 4.14 mm), who pitched more than 5 innings per appearance (4.76 vs 4.11 mm), and who had more than 5.5 years of pitching experience (4.71 vs 4.07 mm; P < .001). Linear regression demonstrated that age, weight, and pitches per appearance (R 2 = 0.114, 0.370, and 0.326, respectively) significantly correlated with UCL thickness. These findings suggest that UCL thickness increases as pitchers get older and heavier and as they increase their pitch volumes. © 2016 The Author(s).

  17. Elbow Pain

    MedlinePlus

    ... tear damage than are many other joints. Seek emergency care if you have: An obvious deformity in ... http://www.mayoclinic.org/symptoms/elbow-pain/basics/definition/SYM-20050874 . Mayo Clinic Footer Legal Conditions and ...

  18. Comparison of dominant hand range of motion among throwing types in baseball pitchers.

    PubMed

    Wang, Lin-Hwa; Kuo, Li-Chieh; Shih, Sheng-Wen; Lo, Kuo-Cheng; Su, Fong-Chin

    2013-08-01

    Previous research on baseball pitchers' wrists, elbows, and should joints contributes to our understanding of pitchers' control over delicate joint motion and ball release. However, limited research on forearm, wrist, and hand joints prevents full comprehension of the throwing mechanism. The present descriptive laboratory study quantifies angular performances of hand and wrist joints while pitching breaking balls, including fastballs, curveballs and sliders, among pitchers with different skill levels. Nineteen baseball pitchers performed required pitching tasks (10 from university and 9 from high school). A three-dimensional motion analysis system collected pitching motion data. The range of joint motion in the wrist and proximal interphalangeal (PIP) and metacarpophalangeal (MP) joints of the index and middle fingers were compared among fastballs, curveballs and sliders. Thirteen reflective markers were placed on selected anatomic landmarks of the wrist, middle and index fingers of the hand. Wrist flexion angle in the pitching acceleration phase was larger in fastballs (20.58±4.07°) and sliders (22.48±5.45°) than in curveballs (9.08±3.03°) (p = .001). The flexion angle of the PIP joint was significantly larger in curveballs (38.5±3.8°) than in fastballs (30.3±4.8°) and sliders (30.2±4.5°) (p=.004) of the middle finger. Abduction angle of MP joint on the middle finger was significantly larger in curveballs (15.4 ±3.6°) than in fastballs (8.9±1.2°) and sliders (6.9±2.9°) (p=.001) of the middle finger, and the abduction angle of index finger was significantly larger in sliders (13.5±15.0°) than in fastballs (7.2 ±2.8°) (p=.007). Hand and wrist motion and grip types affect the relative position between fingers and ball, which produces different types of baseball pitches. A larger extension angle of the wrist joint and the coordination of middle and index fingers are crucial when pitching a fastball. Abduction and flexion movement on the MP joint of the middle finger are important for a curveball. MP joint abduction and flexion movement of the index finger produce sliders. Understanding the control mechanism in a throwing hand can help improve training protocols in either injury prevention or performance improvement for baseball pitchers. Copyright © 2013 Elsevier B.V. All rights reserved.

  19. [APPLICATION OF COMPRESSION MINI-SCREWS IN TREATMENT OF PATIENTS WITH INJURY OF ELBOW JOINT BONES].

    PubMed

    Neverov, V A; Egorov, K S

    2015-01-01

    A case report presents the experience of application of compression pileateless mini-screws (Gerbert's screws) in treatment of intra-articular fractures, which formed the elbow joint (44 cases). There were performed 32 operations concerning fracture of head of radius, 10 operations on the occasion of fractures of distal section of the humerus and 2 operations on the coronoid process. Long-term treatment results were followed-up in 31 patients during more than 6 months. On basis of analysis of treatment results the authors made a conclusion that the application of mini-screws in case of bone fractures, which formed the elbow joint, allowed realization of stable osteosynthesis after anatomic reposition of articular surfaces, obtaining good anatomical and functional result and shortened the terms of patient's treatment.

  20. Reliability and precision of stress sonography of the ulnar collateral ligament.

    PubMed

    Bica, David; Armen, Joseph; Kulas, Anthony S; Youngs, Kevin; Womack, Zachary

    2015-03-01

    Musculoskeletal sonography has emerged as an additional diagnostic tool that can be used to assess medial elbow pain and laxity in overhead throwers. It provides a dynamic, rapid, and noninvasive modality in the evaluation of ligamentous structural integrity. Many studies have demonstrated the utility of dynamic sonography for medial elbow and ulnar collateral ligament (UCL) integrity. However, evaluating the reliabilityand precision of these measurements is critical if sonography is ultimately used as a clinical diagnostic tool. The purpose of this study was to evaluate the reliability and precision of stress sonography applied to the medial elbow. We conducted a cross-sectional study during the 2011 baseball off-season. Eighteen National Collegiate Athletic Association Division I pitchers were enrolled, and 36 elbows were studied. Using sonography, the medial elbow was assessed, and measurements of the UCL length and ulnohumeral joint gapping were performed twice under two conditions (unloaded and loaded) and bilaterally. Intraclass correlation coefficients (0.72-0.94) and standard errors of measurements (0.3-0.9 mm) for UCL length and ulnohumeral joint gapping were good to excellent. Mean differences between unloaded and loaded conditions for the dominant arms were 1.3 mm (gapping; P < .001) and 1.4 mm (UCL length; P < .001). Medial elbow stress sonography is a reliable and precise method for detecting changes in ulnohumeral joint gapping and UCL lengthening. Ultimately, this method may provide clinicians valuable information regarding the medial elbow's response to valgus loading and may help guide treatment options. © 2015 by the American Institute of Ultrasound in Medicine.

  1. Prevalence and co-occurrence of hip dysplasia and elbow dysplasia in Dutch pure-bred dogs.

    PubMed

    Lavrijsen, I C M; Heuven, H C M; Meij, B P; Theyse, L F H; Nap, R C; Leegwater, P A J; Hazewinkel, H A W

    2014-05-01

    Hip as well as elbow dysplasia (HD, ED) are developmental disorders leading to malformation of their respective joints. For a long time both disorders have been scored and targeted for improvement using selective breeding in several Dutch dog populations. In this paper all scores for both HD and ED, given to pure bred dogs in the Netherlands from 2002 to 2010, were analyzed. Heritabilities and correlations between HD and ED were calculated for the 4 most frequently scored breeds. Heritabilities ranged from 0.0 to 0.37 for HD related traits (FCI-score, osteoarthritis, congruity, shape and laxity (Norberg angle); FCI: Fédération Cynologique Internationale) and from 0.0 to 0.39 for ED related traits (IEWG score, osteoarthritis, sclerosis and indentation; IEWG: International Elbow Working Group). HD related traits showed high genetic and residual correlations among each other but were only to a minor extent correlated with ED related traits, which also showed high correlations among each other. Genetic correlations were higher than residual correlations. Phenotypic and genetic trends since 2001 for the four most scored breeds were slightly positive but decreasing over time, indicating that selection over the past decade has not been effective. Copyright © 2014. Published by Elsevier B.V.

  2. Influence of different shoulder-elbow configurations on steering precision and steering velocity in automotive context.

    PubMed

    Schmidt, Susanne; Seiberl, Wolfgang; Schwirtz, Ansgar

    2015-01-01

    Ergonomic design requirements are needed to develop optimum vehicle interfaces for the driver. The majority of the current specifications consider only anthropometric conditions and subjective evaluations of comfort. This paper examines specific biomechanical aspects to improve the current ergonomic requirements. Therefore, a research which involved 40 subjects was carried out to obtain more knowledge in the field of steering movement while driving a car. Five different shoulder-elbow joint configurations were analyzed using a driving simulator to find optimum posture for driving in respect of steering precision and steering velocity. Therefore, a 20 s precision test and a test to assess maximum steering velocity over a range of 90° steering motion have been conducted. The results show that driving precision, as well as maximum steering velocity, are significantly increased in mid-positions (elbow angles of 95° and 120°) compared to more flexed (70°) or extended (145° and 160°) postures. We conclude that driver safety can be enhanced by implementing these data in the automotive design process because faster and highly precise steering can be important during evasive actions and in accident situations. In addition, subjective comfort rating, analyzed with questionnaires, confirmed experimental results. Copyright © 2014 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  3. A target field design of open multi-purpose RF coil for musculoskeletal MR imaging at 3T.

    PubMed

    Gao, Fei; Zhang, Rui; Zhou, Diange; Wang, Xiaoying; Huang, Kefu; Zhang, Jue

    2016-10-01

    Musculoskeletal MR imaging under multi-angle situations plays an increasingly important role in assessing joint and muscle tissues system. However, there are still limitations due to the closed structures of most conventional RF coils. In this study, a time-harmonic target-field method was employed to design open multi-purpose coil (OMC) for multi-angle musculoskeletal MR imaging. The phantom imaging results suggested that the proposed OMC could achieve homogeneously distributed magnetic field and high signal-to-noise ratio (SNR) of 239.04±0.83 in the region of interest (ROI). The maximum temperature in the heating hazard test was 16°C lower than the standard regulation, which indicated the security of the designed OMC. Furthermore, to demonstrate the effectiveness of the proposed OMC for musculoskeletal MR imaging, especially for multi-angle imaging, a healthy volunteer was examined for MR imaging of elbow, ankle and knee using OMC. The in vivo imaging results showed that the proposed OMC is effective for MR imaging of musculoskeletal tissues at different body parts, with satisfied B1 field homogeneity and SNR. Moreover, the open structure of the OMC could provide a large joint movement region. The proposed open multi-purpose coil is feasible for musculoskeletal MR imaging, and potentially, it is more suitable for the evaluation of musculoskeletal tissues under multi-angle conditions. Copyright © 2016. Published by Elsevier Inc.

  4. The role of total elbow arthroplasty in traumatology.

    PubMed

    Mansat, P; Bonnevialle, N; Rongières, M; Bonnevialle, P

    2014-10-01

    Fractures of the distal humerus account for 5% of osteoporotic fractures in subjects older than 60 years. A history of osteoporosis, co-morbidities, and joint comminution make their management difficult. The therapeutic options are limited to functional treatments, osteosynthesis, or either partial or total arthroplasty. Functional treatment of distal humerus fractures in the elderly subject provide inconsistent results, often with persistence of pain with a stiff or unstable elbow. Osteosynthesis remains the reference treatment for these fractures, following the principle of stable and rigid osteosynthesis allowing early mobilization. However, joint comminution and a history of osteoporosis occasionally make it impossible to meet this objective, with a considerable rate of complications and surgical revisions. Total elbow arthroplasty remains an alternative to osteosynthesis with very satisfactory immediate results restoring a painless, stable, and functional elbow. These results seem reproducible and sustainable over time. The complication rate is not uncommon with an approximately 10% surgical revision rate. Elbow hemiarthroplasty remains to be validated in this indication. V. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  5. Use of commercially available foam pipe insulation as a protective device for wounds over the elbow joint area in five dogs.

    PubMed

    Pavletic, Michael M

    2011-11-01

    4 large-breed dogs were referred because of nonhealing skin wounds involving the elbow joint area of several weeks to months in duration. One additional large-breed dog was evaluated because of a draining abscess with overlying skin necrosis. Previous attempts at closing each wound over the elbow joint area had been unsuccessful. At the time of hospital admission, open wounds had variable degrees of bacterial contamination and infection. Open wounds over the elbow joint area were closed by use of bipedicle advancement flaps or direct suture apposition of opposing sides of the wound. Lengths of pipe insulation were applied to the forelimb in a fashion to prevent contact pressure to the olecranon for a prolonged period (4 to 13 weeks) after surgery. All wounds healed completely. Release incisions (donor areas) healed by second intention within 3 weeks after surgery. One dog developed periostitis of the olecranon, which responded to antimicrobial administration. A second dog developed a skin bacterial infection below the surgical area that was markedly resistant to antimicrobials. The layered application of commercially available foam pipe insulation provided a simple and economical protective device after closure of problematic skin wounds involving the elbow joint area. Prolonged protection of the olecranon area helped to assure healing was complete and skin coverage was sufficiently stable to reduce the risk of reinjury after removal of the device. Each patient was able to use the involved forelimb during the treatment period. Paired bipedicle advancement flaps (release incisions) were particularly useful for closing small to moderate defects overlying the olecranon in which simple apposition was not feasible.

  6. Exposures of the elbow.

    PubMed

    Axelrod, Terry S

    2014-11-01

    This article describes the basic bony, ligamentous, and neurologic anatomy of the structures about the elbow. The surgical exposures of the elbow joint are described, providing details of the various posterior, lateral, and medial approaches to the articular segments. Clinical applications describing the potential benefits of each surgical exposure are provided as examples. Copyright © 2014 Elsevier Inc. All rights reserved.

  7. Relative ratios of collagen composition of periarticular tissue of joints of the upper limb.

    PubMed

    Cheah, A; Harris, A; Le, W; Huang, Y; Yao, J

    2017-07-01

    We investigated the relative ratios of collagen composition of periarticular tissue of the elbow, wrist, metacarpophalangeal, proximal and distal interphalangeal joints. Periarticulat tissue, which we defined as the ligaments, palmar plate and capsule, was harvested from ten fresh-frozen cadaveric upper limbs, yielding 50 samples. The mean paired differences (95% confidence interval) of the relative ratios of collagen between the five different joints were estimated using mRNA expression of collagen in the periarticular tissue. We found that the relative collagen composition of the elbow was not significantly different to that of the proximal interphalangeal joint, nor between the proximal interphalangeal joint and distal interphalangeal joint, whereas the differences in collagen composition between all the other paired comparisons of the joints had confidence intervals that did not include zero.

  8. The posterior transtriceps approach for elbow arthrography: a forgotten technique?

    PubMed

    Lohman, M; Borrero, C; Casagranda, B; Rafiee, B; Towers, J

    2009-05-01

    To evaluate the technical feasibility of performing elbow MR arthrography via a posterior approach through the triceps. The images of 19 patients with elbow MR arthrography via a posterior transtriceps approach were retrospectively studied. The injections were performed by four musculoskeletal radiologists, using fluoroscopic guidance and a 22- or 25-gauge needle. The fluoroscopic and subsequent MR images were reviewed by two musculoskeletal radiologists and evaluated for adequacy of joint capsular distention, degree and location of contrast leakage, and presence of gas bubbles. The injection was diagnostic in all 19 patients, with a sufficient amount of contrast agent seen in the elbow joint. No significant contrast leakage occurred in 12 patients who received injections of 8 cc or less of contrast agent, but moderate contrast leakage occurred in 6/7 patients who received injections of greater than 8 cc. Contrast leakage generally occurred within the triceps myotendinous junction. No gas bubbles were identified in the injected joints. Patients often present for MR arthrography of the elbow with medial or lateral elbow pain. Contrast leakage during a radiocapitellar approach may complicate evaluation of the lateral collateral ligament or the common extensor tendon origin. Transtriceps MR arthrography offers an alternative to the more commonly used radiocapitellar approach. With injected volumes not exceeding 8 cc, the risk of significant contrast leakage is small. An advantage of the transtriceps injection is that contrast leakage through the posterior needle tract does not interfere with evaluation of the lateral structures.

  9. Translational control of a graphically simulated robot arm by kinematic rate equations that overcome elbow joint singularity

    NASA Technical Reports Server (NTRS)

    Barker, L. K.; Houck, J. A.; Carzoo, S. W.

    1984-01-01

    An operator commands a robot hand to move in a certain direction relative to its own axis system by specifying a velocity in that direction. This velocity command is then resolved into individual joint rotational velocities in the robot arm to effect the motion. However, the usual resolved-rate equations become singular when the robot arm is straightened. To overcome this elbow joint singularity, equations were developed which allow continued translational control of the robot hand even though the robot arm is (or is nearly) fully extended. A feature of the equations near full arm extension is that an operator simply extends and retracts the robot arm to reverse the direction of the elbow bend (difficult maneuver for the usual resolved-rate equations). Results show successful movement of a graphically simulated robot arm.

  10. An explorative, cross-sectional study into abnormal muscular coupling during reach in chronic stroke patients

    PubMed Central

    2010-01-01

    Background In many stroke patients arm function is limited, which can be related to an abnormal coupling between shoulder and elbow joints. The extent to which this can be translated to activities of daily life (ADL), in terms of muscle activation during ADL-like movements, is rather unknown. Therefore, the present study examined the occurrence of abnormal coupling on functional, ADL-like reaching movements of chronic stroke patients by comparison with healthy persons. Methods Upward multi-joint reaching movements (20 repetitions at a self-selected speed to resemble ADL) were compared in two conditions: once facilitated by arm weight compensation and once resisted to provoke a potential abnormal coupling. Changes in movement performance (joint angles) and muscle activation (amplitude of activity and co-activation) between conditions were compared between healthy persons and stroke patients using a repeated measures ANOVA. Results The present study showed slight changes in joint excursion and muscle activation of stroke patients due to shoulder elevation resistance during functional reach. Remarkably, in healthy persons similar changes were observed. Even the results of a sub-group of the more impaired stroke patients did not point to an abnormal coupling between shoulder elevation and elbow flexion during functional reach. Conclusions The present findings suggest that in mildly and moderately affected chronic stroke patients ADL-like arm movements are not substantially affected by abnormal synergistic coupling. In this case, it is implied that other major contributors to limitations in functional use of the arm should be identified and targeted individually in rehabilitation, to improve use of the arm in activities of daily living. PMID:20233402

  11. The effect of seat position on manual wheelchair propulsion biomechanics: a quasi-static model-based approach.

    PubMed

    Richter, W M

    2001-12-01

    The position of the seat relative to the rear wheels is generally adjusted to modify the rearward stability of the wheelchair. Recent studies have shown that seat position also has an effect on propulsion biomechanics and suggest that seat position can be optimized. A quasi-static wheelchair propulsion model was developed to investigate the mechanism by which seat position affects propulsion biomechanics. Inputs to the model include the length of the user's arm segments, the position of the user's shoulder, the size of handrim used and the force profile on the handrim. Outputs from the model include joint kinematics, joint torques, push angle, and push frequency. Handrim force profile was determined by averaging the force profile of five wheelchair users. Force profiles were measured using the SMARTWheel. The effect of seat position on push angle was found to be directly affected by the length of the position vector from the hub of the wheel to the shoulder and indirectly affected by the angular orientation of the vector. Decreasing hub to shoulder length was found to increase push angle, decrease push frequency, decrease shoulder torque and increase elbow extension torque. It is suggested that future research investigating the role of seat position on propulsion biomechanics include both the kinematics and kinetics of the upper extremity.

  12. The role of arthroscopy in chronic elbow instability.

    PubMed

    Goodwin, David; Dynin, Maria; Macdonnell, J Ryan; Kessler, Michael W

    2013-12-01

    Elbow arthroscopy has had an emerging role in the management of many disorders of the elbow. In patients with chronic elbow instability, several arthroscopic techniques have been described in the diagnosis and management of posterolateral rotatory instability and valgus instability. We performed a systematic review investigating the role of arthroscopy in posterolateral rotatory instability and valgus instability in the elbow using the PubMed and CINAHL (Cumulative Index to Nursing and Allied Health Literature) databases, and the Cochrane Database of Systematic Reviews, consisting of articles from peer-reviewed journals published in the English language after January 1, 1991. Search criteria initially identified 249 articles. Twenty-five articles met criteria for inclusion. This included 17 review articles, 4 cadaveric studies, 3 retrospective studies, and 1 prospective study. Two of the retrospective studies compared arthroscopic and open techniques. Articles included in this systematic review concluded that arthroscopy is an accurate adjunct to physical examination and imaging in the diagnosis of chronic elbow instability and affords an exceptional view of the joint with the ability to address intra-articular pathologic conditions. Arthroscopic surgical techniques have shown equivalent clinical outcomes in a comparison of arthroscopic and open techniques. Elbow arthroscopy is a valuable tool in the diagnosis and management of chronic elbow instability. Patients treated arthroscopically benefit from additional diagnostic techniques, improved visualization of the elbow joint, the ability to address coexisting intra-articular pathologic conditions, and minimal soft tissue injury with no clinical consequences in outcomes. With such significant advantages, the use of elbow arthroscopy is likely to expand in the management of chronic elbow instability. Level IV, systematic review. Copyright © 2013 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  13. Surgical robot for single-incision laparoscopic surgery.

    PubMed

    Choi, Hyundo; Kwak, Ho-Seong; Lim, Yo-An; Kim, Hyung-Joo

    2014-09-01

    This paper introduces a novel surgical robot for single-incision laparoscopic surgeries. The robot system includes the cone-type remote center-of-motion (RCM) mechanism and two articulated instruments having a flexible linkage-driven elbow. The RCM mechanism, which has two revolute joints and one prismatic joint, is designed to maintain a stationary point at the apex of the cone shape. By placing the stationary point on the incision area, the mechanism allows a surgical instrument to explore the abdominal area through a small incision point. The instruments have six articulated joints, including an elbow pitch joint, which make the triangulation position for the surgery possible inside of the abdominal area. The presented elbow pitch structure is similar to the slider-crank mechanism but the connecting rod is composed of a flexible leaf spring for high payload and small looseness error. We verified the payload of the robot is more than 10 N and described preliminary experiments on peg transfer and suture motion by using the proposed surgical robot.

  14. The articulo-cardiac sympathetic reflex in spinalized, anesthetized rats.

    PubMed

    Nakayama, Tomohiro; Suzuki, Atsuko; Ito, Ryuzo

    2006-04-01

    Somatic afferent regulation of heart rate by noxious knee joint stimulation has been proven in anesthetized cats to be a reflex response whose reflex center is in the brain and whose efferent arc is a cardiac sympathetic nerve. In the present study we examined whether articular stimulation could influence heart rate by this efferent sympathetic pathway in spinalized rats. In central nervous system (CNS)-intact rats, noxious articular movement of either the knee or elbow joint resulted in an increase in cardiac sympathetic nerve activity and heart rate. However, although in acutely spinalized rats a noxious movement of the elbow joint resulted in a significant increase in cardiac sympathetic nerve activity and heart rate, a noxious movement of the knee joint had no such effect and resulted in only a marginal increase in heart rate. Because this marginal increase was abolished by adrenalectomy suggests that it was due to the release of adrenal catecholamines. In conclusion, the spinal cord appears to be capable of mediating, by way of cardiac sympathetic nerves, the propriospinally induced reflex increase in heart rate that follows noxious stimulation of the elbow joint, but not the knee joint.

  15. Hinged external fixation of the elbow.

    PubMed

    Chen, Neal C; Julka, Abhishek

    2010-08-01

    Hinged external fixation of the elbow provides the advantages of static fixation with the benefits of continued motion through the joint. Indications for the use of this method of fixation include traumatic instability, distraction interposition arthroplasty, instability after contracture release, and instability after excision of heterotopic ossification. Orthopedic surgeons should be familiar with hinged fixators and their application when faced with an unstable ulnohumeral joint. 2010 Elsevier Inc. All rights reserved.

  16. Incidence of elbow injuries in adolescent baseball players: screening by a low field magnetic resonance imaging system specialized for small joints.

    PubMed

    Okamoto, Yoshikazu; Maehara, Kiyoshi; Kanahori, Tetsuya; Hiyama, Takashi; Kawamura, Takashi; Minami, Manabu

    2016-04-01

    The aim of this preliminary study was to examine the capability of screening for elbow injuries induced by baseball using a low field small joint MRI system. Sixty-two players in the 4th-6th elementary school grades, with ages ranging from 9 to 12 years, participated in this study. Screening for elbow injuries was performed using a low-magnetic-field (0.2-T) magnetic resonance imaging (MRI) system designed for examinations of small joints of the extremities. Gradient-echo coronal, sagittal, and short-tau inversion recovery (STIR) coronal images of the dominant arm used for pitching were obtained to identify medial collateral ligament (MCL) injuries with or without avulsion fracture and osteochondritis dissecans. All 62 examinations were performed successfully, with 26 players (41.9 %) showing positive findings, all being confined to the MCL. No child showed bone damage. All criteria in the MRI evaluation of injuries showed high agreement rates and kappa values between two radiologists. Screening for early detection of elbow injuries in junior Japanese baseball players can be successfully performed using a low-field MRI system specialized for small joints. The percentage of MCL injury without avulsion fracture was unexpectedly high (41.9 %).

  17. Elbow arthroscopy.

    PubMed

    Dodson, Christopher C; Nho, Shane J; Williams, Riley J; Altchek, David W

    2008-10-01

    Arthroscopy of the elbow was originally considered to be an unsafe procedure because of the small size of the elbow joint capsule and its proximity to several crucial neurovascular structures. Over the past decade, however, the procedure has become safer and more effective. These improvements can be attributed to a better understanding of elbow anatomy and of the disorders about the elbow as well as to advances in arthroscopic equipment and surgical technique. The most common indications for elbow arthroscopy include removal of loose bodies, synovectomy, débridement and/or excision of osteophytes, capsular release, and the assessment and treatment of osteochondritis dissecans. More recent advances have expanded the indications of elbow arthroscopy to include fracture management (eg, radial head fractures) and the treatment of lateral epicondylitis.

  18. A systematic, multimodality approach to emergency elbow imaging.

    PubMed

    Singer, Adam D; Hanna, Tarek; Jose, Jean; Datir, Abhijit

    2016-01-01

    The elbow is a complex synovial hinge joint that is frequently involved in both athletic and nonathletic injuries. A thorough understanding of the normal anatomy and various injury patterns is essential when utilizing diagnostic imaging to identify damaged structures and to assist in surgical planning. In this review, the elbow anatomy will be scrutinized in a systematic approach. This will be followed by a comprehensive presentation of elbow injuries that are commonly seen in the emergency department accompanied by multimodality imaging findings. A short discussion regarding pitfalls in elbow imaging is also included. Copyright © 2015 Elsevier Inc. All rights reserved.

  19. The Bare Area of the Proximal Ulna: An Anatomic Study With Relevance to Chevron Osteotomy.

    PubMed

    Ao, Rongguang; Zhang, Xu; Li, Dejian; Chen, Fancheng; Zhou, Jianhua; Yu, Baoqing

    2017-06-01

    A chevron osteotomy of the ulna is widely used to obtain intra-articular access to the elbow in the treatment of type C distal humerus fractures. The trochlear notch of the proximal ulna is divided into 2 articular parts by the "bare area." Ideally, the olecranon osteotomy should be centered on the bare area to minimize damage to the joint cartilage. The goals of this study were to describe the anatomy of the bare area and design an ideal chevron-shaped osteotomy. We dissected 38 cadaver elbows and measured the width of the bare area, the distance between the tip of the triceps insertion and the area on the olecranon cortex corresponding to the bare area. We then designed a chevron osteotomy to stay within the bare area and measured the distance from the tip of the triceps insertion to the osteotomy apex as well as the angle of the osteotomy plane and the angle of the chevron cuts. The bare area existed in all 38 cadavers. The mean longitudinal and transverse widths were 4.0 mm (range, 1.0-8.6 mm) and 19.0 mm (range, 16.9-23.8 mm), respectively. The mean distance between the tip of the triceps insertion and the area on the olecranon cortex corresponding to the bare area was 19.0 mm (range, 16.0-23.0 mm). The mean transverse and longitudinal widths of the cortical notch were 3.0 mm (range, 1.6-4.5 mm) and 8.0 mm (range, 6.5-14.8 mm), respectively. The mean distance between the tip of the triceps insertion and the osteotomy apex was 22.0 mm (range, 18.0-24.0 mm) and the mean angle between the osteotomy surface and the vertical plane corresponding to the tangent plane was 20° (range, 10° to 25°). The mean angle of the V shape was 140° (range, 130° to 150°). Using the narrowest edge lacking cartilage (lateral or medial side) as a point of reference to locate the bare area, the designed chevron osteotomy entered the joint in the bare area in most specimens and decreased associated damage to the joint cartilage. This study describes the anatomy of the bare area and the design of the ideal chevron-shaped osteotomy to treat type C distal humerus fractures. Copyright © 2017 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  20. Infectious Arthritis

    MedlinePlus

    Most kinds of arthritis cause pain and swelling in your joints. Joints are places where two bones meet, such as your elbow or knee. Infectious arthritis is an infection in the joint. The infection ...

  1. Medial elbow pain

    PubMed Central

    Barco, Raul; Antuña, Samuel A.

    2017-01-01

    Medial elbow pain is uncommon when compared with lateral elbow pain. Medial epicondylitis is an uncommon diagnosis and can be confused with other sources of pain. Overhead throwers and workers lifting heavy objects are at increased risk of medial elbow pain. Differential diagnosis includes ulnar nerve disorders, cervical radiculopathy, injured ulnar collateral ligament, altered distal triceps anatomy or joint disorders. Children with medial elbow pain have to be assessed for ‘Little League elbow’ and fractures of the medial epicondyle following a traumatic event. This paper is primarily focused on the differential diagnosis of medial elbow pain with basic recommendations on treatment strategies. Cite this article: EFORT Open Rev 2017;2:362-371. DOI: 10.1302/2058-5241.2.160006 PMID:28932488

  2. Phase-II Clinical Validation of a Powered Exoskeleton for the Treatment of Elbow Spasticity

    PubMed Central

    Crea, Simona; Cempini, Marco; Mazzoleni, Stefano; Carrozza, Maria Chiara; Posteraro, Federico; Vitiello, Nicola

    2017-01-01

    Introduction: Spasticity is a typical motor disorder in patients affected by stroke. Typically post-stroke rehabilitation consists of repetition of mobilization exercises on impaired limbs, aimed to reduce muscle hypertonia and mitigate spastic reflexes. It is currently strongly debated if the treatment's effectiveness improves with the timeliness of its adoption; in particular, starting intensive rehabilitation as close as possible to the stroke event may counteract the growth and postpone the onset of spasticity. In this paper we present a phase-II clinical validation of a robotic exoskeleton in treating subacute post-stroke patients. Methods: Seventeen post-stroke patients participated in 10 daily rehabilitation sessions using the NEUROExos Elbow Module exoskeleton, each one lasting 45 min: the exercises consisted of isokinetic passive mobilization of the elbow, with torque threshold to detect excessive user's resistance to the movement. We investigated the safety by reporting possible adverse events, such as mechanical, electrical or software failures of the device or injuries or pain experienced by the patient. As regards the efficacy, the Modified Ashworth Scale, was identified as primary outcome measure and the NEEM metrics describing elbow joint resistance to passive extension (i.e., maximum extension torque and zero-torque angle) as secondary outcomes. Results: During the entire duration of the treatments no failures or adverse events for the patients were reported. No statistically significant differences were found in the Modified Ashworth Scale scores, between pre-treatment and post-treatment and between post-treatment and follow-up sessions, indicating the absence of spasticity increase throughout (14 days) and after (3–4 months follow-up) the treatment. Exoskeleton metrics confirmed the absence of significant difference in between pre- and post-treatment data, whereas intra-session data highlighted significant differences in the secondary outcomes, toward a decrease of the subject's joint resistance. Conclusions: The results show that our robotic exoskeleton can be safely used for prolonged sessions in post-stroke and suggest that intensive early rehabilitation treatment may prevent the occurrence of spasticity at a later stage. Moreover, the NEEM metrics were found to be reliable compared to the Modified Ashworth Scale and sensitive to revealing intra-session changes of elbow resistance to passive extension, in agreement with clinical evidences. PMID:28553200

  3. Phase-II Clinical Validation of a Powered Exoskeleton for the Treatment of Elbow Spasticity.

    PubMed

    Crea, Simona; Cempini, Marco; Mazzoleni, Stefano; Carrozza, Maria Chiara; Posteraro, Federico; Vitiello, Nicola

    2017-01-01

    Introduction: Spasticity is a typical motor disorder in patients affected by stroke. Typically post-stroke rehabilitation consists of repetition of mobilization exercises on impaired limbs, aimed to reduce muscle hypertonia and mitigate spastic reflexes. It is currently strongly debated if the treatment's effectiveness improves with the timeliness of its adoption; in particular, starting intensive rehabilitation as close as possible to the stroke event may counteract the growth and postpone the onset of spasticity. In this paper we present a phase-II clinical validation of a robotic exoskeleton in treating subacute post-stroke patients. Methods: Seventeen post-stroke patients participated in 10 daily rehabilitation sessions using the NEUROExos Elbow Module exoskeleton, each one lasting 45 min: the exercises consisted of isokinetic passive mobilization of the elbow, with torque threshold to detect excessive user's resistance to the movement. We investigated the safety by reporting possible adverse events, such as mechanical, electrical or software failures of the device or injuries or pain experienced by the patient. As regards the efficacy , the Modified Ashworth Scale, was identified as primary outcome measure and the NEEM metrics describing elbow joint resistance to passive extension (i.e., maximum extension torque and zero-torque angle) as secondary outcomes. Results: During the entire duration of the treatments no failures or adverse events for the patients were reported. No statistically significant differences were found in the Modified Ashworth Scale scores, between pre-treatment and post-treatment and between post-treatment and follow-up sessions, indicating the absence of spasticity increase throughout (14 days) and after (3-4 months follow-up) the treatment. Exoskeleton metrics confirmed the absence of significant difference in between pre- and post-treatment data, whereas intra-session data highlighted significant differences in the secondary outcomes, toward a decrease of the subject's joint resistance. Conclusions: The results show that our robotic exoskeleton can be safely used for prolonged sessions in post-stroke and suggest that intensive early rehabilitation treatment may prevent the occurrence of spasticity at a later stage. Moreover, the NEEM metrics were found to be reliable compared to the Modified Ashworth Scale and sensitive to revealing intra-session changes of elbow resistance to passive extension, in agreement with clinical evidences.

  4. EFFICACY OF TENNIS ELBOW (EPICONDYLITIS HUMERI RADIALIS) TREATMENT IN CBR “PRAXIS”

    PubMed Central

    Pecar, Džemal; Avdić, Dijana

    2009-01-01

    Tennis elbow (Epicondylitis humeri radialis) is the most frequent reason that patients with elbow pain report to a physician. The exact cause of elbow pain is still unclear. However, it is certainly causally connected with connective intersection between forearm muscle and bone in the elbow region. In this paper, we analyzed patients that, over the period of 15 years, reported to “Praxis” clinic for elbow pain treatment (Epicondylitis humeri radialis). Of the total number of 228 patients, 126 were male, 101 female while one patient was younger than 14. Initial analysis established that average overall health condition grade was 2,87 at the onset of treatment. Following the treatment completion that grade was 4,48. Of the total number of 223 patients who were treated by combined method of manipulation and local corticosteroid instillation, eight patients received physical therapy as well. Thus, surgical treatment was not necessary in any patient. The patients’ treatment included: Application of manipulative methods in order to reestablish mobility in the “blocked” radio-humeral and the upper radio-ulnar joints. Local instillation of corticosteroid depot in order to control inflammation (enthesitis) and thus, eliminate pain and establish physiological conditions for functioning of joint and local structures. Unlike conservative method which includes initial immobilization due to irritation and inflammation development prevention with concomitant analgesic and antirheumatic therapy, initial application of manipulation with reinstatement of joint mobility instead of immobilization with subsequent instillation of steroid preparations achieves functional restitution and fast reinstatement of full working ability, as a rule. PMID:19284391

  5. Efficacy of tennis elbow (epicondylitis humeri radialis) treatment in CBR "Praxis".

    PubMed

    Pecar, Dzemal; Avdić, Dijana

    2009-02-01

    Tennis elbow (Epicondylitis humeri radialis) is the most frequent reason that patients with elbow pain report to a physician. The exact cause of elbow pain is still unclear. However, it is certainly causally connected with connective intersection between forearm muscle and bone in the elbow region. In this paper, we analyzed patients that, over the period of 15 years, reported to "Praxis" clinic for elbow pain treatment (Epicondylitis humeri radialis). Of the total number of 228 patients, 126 were male, 101 female while one patient was younger than 14. Initial analysis established that average overall health condition grade was 2,87 at the onset of treatment. Following the treatment completion that grade was 4,48. Of the total number of 223 patients who were treated by combined method of manipulation and local corticosteroid instillation, eight patients received physical therapy as well. Thus, surgical treatment was not necessary in any patient. The patients' treatment included: 1. Application of manipulative methods in order to reestablish mobility in the "blocked" radio-humeral and the upper radio-ulnar joints. 2. Local instillation of corticosteroid depot in order to control inflammation (enthesitis) and thus, eliminate pain and establish physiological conditions for functioning of joint and local structures. Unlike conservative method which includes initial immobilization due to irritation and inflammation development prevention with concomitant analgesic and antirheumatic therapy, initial application of manipulation with reinstatement of joint mobility instead of immobilization with subsequent instillation of steroid preparations achieves functional restitution and fast reinstatement of full working ability, as a rule.

  6. Evaluation of a collagenase generated osteoarthritis biomarker in the synovial fluid from elbow joints of dogs with medial coronoid disease and unaffected dogs.

    PubMed

    Prink, Adam; Hayashi, Kei; Kim, Sun-Young; Kim, James; Kapatkin, Amy

    2010-01-01

    To evaluate whether synovial fluid concentrations of an osteoarthritis biomarker in dysplastic canine elbows with medial coronoid disease (MCD) are elevated compared with unaffected elbows and to determine if these concentrations correlate to the degree of articular cartilage damage. Cross sectional clinical study. Dogs (n=19; 35 elbows) with MCD and dogs (8; 16 elbows) with unaffected elbows. Concentrations of a collagenase-generated cleavage neoepitope of type II collagen (Col2-3/4C(long mono), or C2C) in joint fluid from elbows were analyzed and compared between dogs with MCD and unaffected dogs. Correlation of C2C concentration with subjective grading of articular cartilage surface damage was also evaluated. Mean (+/-SD) C2C concentration from MCD dogs was significantly higher (112.3+/-24.8 ng/mL) than in unaffected dogs (76.1+/-16.9 ng/mL; P<.05). There was a moderate correlation between cartilage damage grade and increasing C2C concentrations (P<.05, r=0.62) C2C concentrations are elevated in the synovial fluid of dogs with MCD compared with unaffected elbows, and a moderate, significant correlation was identified between these concentrations and subjective grading of articular cartilage damage. This preliminary data suggest that C2C concentrations in synovial fluid may have potential as a biomarker for diagnosis of articular cartilage damage associated with MCD and as a means of objectively determining the degree of articular cartilage damage.

  7. Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation

    PubMed Central

    Koh, Tze Hui; Cheng, Nicholas; Yap, Hong Kai; Yeow, Chen-Hua

    2017-01-01

    The provision of continuous passive, and intent-based assisted movements for neuromuscular training can be incorporated into a robotic elbow sleeve. The objective of this study is to propose the design and test the functionality of a soft robotic elbow sleeve in assisting flexion and extension of the elbow, both passively and using intent-based motion reinforcement. First, the elbow sleeve was developed, using elastomeric and fabric-based pneumatic actuators, which are soft and lightweight, in order to address issues of non-portability and poor alignment with joints that conventional robotic rehabilitation devices are faced with. Second, the control system was developed to allow for: (i) continuous passive actuation, in which the actuators will be activated in cycles, alternating between flexion and extension; and (ii) an intent-based actuation, in which user intent is detected by surface electromyography (sEMG) sensors attached to the biceps and triceps, and passed through a logic sequence to allow for flexion or extension of the elbow. Using this setup, the elbow sleeve was tested on six healthy subjects to assess the functionality of the device, in terms of the range of motion afforded by the device while in the continuous passive actuation. The results showed that the elbow sleeve is capable of achieving approximately 50% of the full range of motion of the elbow joint among all subjects. Next, further experiments were conducted to test the efficacy of the intent-based actuation on these healthy subjects. The results showed that all subjects were capable of achieving electromyography (EMG) control of the elbow sleeve. These preliminary results show that the elbow sleeve is capable of carrying out continuous passive and intent-based assisted movements. Further investigation of the clinical implementation of the elbow sleeve for the neuromuscular training of neurologically-impaired persons, such as stroke survivors, is needed. PMID:29118693

  8. Ulnohumeral chondral and ligamentous overload: biomechanical correlation for posteromedial chondromalacia of the elbow in throwing athletes.

    PubMed

    Osbahr, Daryl C; Dines, Joshua S; Breazeale, Nathan M; Deng, Xiang-Hua; Altchek, David W

    2010-12-01

    Previous studies have documented increased posteromedial contact forces with the elbow at lower flexion angles associated with valgus extension overload; however, the authors believe that posteromedial elbow impingement in association with valgus laxity is a complex pathological process that may occur throughout the entire throwing motion in the form of ulnohumeral chondral and ligamentous overload. Valgus laxity with the elbow at 90° of flexion may lead to chondromalacia secondary to a subtle shift in the contact point between the tip of the olecranon and the distal humeral trochlea. Controlled laboratory study. Six fresh human cadaveric elbows were dissected and subjected to a static valgus load. Pressure-sensitive Fuji film measured the contact pressure, contact area, and shift in contact area across the posteromedial elbow before and after sectioning the anterior bundle of the ulnar collateral ligament. The contact pressure between the tip of the olecranon process and the medial crista of the posterior humeral trochlea significantly increased, from an average of 0.27 ± 0.06 kg/cm² to 0.40 ± 0.08 kg/cm². The contact area also significantly decreased, from an average of 30.34 ± 9.17 mm² to 24.59 ± 6.44 mm², and shifted medially on the medial humeral crista, which corresponds to the position of the posteromedial chondral lesions that was observed in throwing athletes in the authors' clinical practice. While simulating the early acceleration phase of the throwing motion with the elbow in 90° of flexion, the results illustrate that abnormal contact may occur as a result of valgus laxity through increased contact pressures across the posteromedial elbow between the medial tip of the olecranon and medial crista of the humeral trochlea. In addition, congruency of the ulnohumeral joint changed, as there was a statistically significant medial shift of the olecranon on the posterior humeral trochlea with the elbow at 90° of flexion after sectioning the anterior bundle of the ulnar collateral ligament. In the throwing athlete who continues the repetitive, throwing motion despite valgus laxity from ulnar collateral ligament insufficiency, the authors believe that these results provide a plausible mechanism for injury throughout the entire throwing motion secondary to ulnohumeral chondral and ligamentous overload. As throwing athletes may produce a tremendous amount of force and subsequent chondromalacia within the posteromedial aspect of the elbow, the findings of this study illustrate the importance of prompt clinical recognition of ulnar collateral ligament insufficiency.

  9. Coactivation of the elbow antagonist muscles is not affected by the speed of movement in isokinetic exercise.

    PubMed

    Bazzucchi, Ilenia; Sbriccoli, Paola; Marzattinocci, Giulia; Felici, Francesco

    2006-02-01

    Since muscle coactivation increases the stiffness and stability of a joint, greater coactivation is likely during faster than slower movements. Very few studies, though, have been conducted to verify this hypothesis. Moreover, a large number of studies have examined coactivation of muscles surrounding the knee joint whereas there are few reports on the elbow joint. The aim of this study was therefore to compare the antagonist activation of the elbow flexors and extensors during isokinetic concentric exercises and to investigate the influence of angular velocity on their activation. Twelve men participated in the study. The surface electromyographic signals (sEMG) were recorded from the biceps brachii (BB) and triceps brachii (TB) muscles during three maximal voluntary isometric contractions (MVC) of elbow flexors and extensors and a set of three maximal elbow flexions and extensions each at 15 degrees, 30 degrees , 60 degrees, 120 degrees, 180 degrees, and 240 degrees.s(-1). Normalized root mean square (RMS) of sEMG was calculated during the isokinetic phase of movement as an index of sEMG amplitude. During elbow flexion, the antagonist activation of BB averaged 16.2% lower than TB, and this difference was statistically significant at all angular velocities. The normalized RMS values ranged from 26.0% +/- 19.0 at MVC to 37.8% +/- 13.9 at 240 degrees.s(-1) for antagonist TB activation, and from 5.7% +/- 5.2 at MVC to 18.9% +/- 8.6 at 240 degrees.s(-1) for antagonist BB activation. No influence of angular velocity on agonist and antagonist activity was found. Moreover, flexion and extension torques were both strongly affected by the amount of antagonist activation. The functional specialization of the two muscle groups could be responsible for the different levels of antagonist activation. The frequent use of BB, which is not assisted by gravity during daily activities, could lead to reduced coactivation due to a better functioning of the control system based upon reciprocal innervation. These findings may have significant implications in the design of rehabilitation programs directed to the elbow joint.

  10. Treatment of post-traumatic elbow deformities in children with the Ilizarov distraction osteogenesis technique.

    PubMed

    Özkan, Cenk; Deveci, Mehmet Ali; Tekin, Mustafa; Biçer, Ömer Sunkar; Gökçe, Kadir; Gülşen, Mahir

    2017-01-01

    The present study assessed functional and radiographic outcomes of distraction osteogenesis treatment of post-traumatic elbow deformities in children. Eight children were treated between 2008 and 2013 for post-traumatic elbow deformities using distraction osteogenesis. Mean age at time of operation was 10.9 years. Six patients had varus and 2 had valgus deformity. Magnitude of correction, fixator index, complications, carrying angle, and elbow range of motion were assessed. Functional results were graded according to protocol of Bellemore et al. Mean follow-up was 43 months. Mean preoperative varus deformity in 6 patients was 29.2° and valgus deformity in 2 patients was 28.5°. Preoperative flexion and extension of elbow were 123.8° and -10.6°, respectively. Mean carrying angle was 9° valgus at last follow-up. Mean flexion and extension were 134.4° and -6.0°, respectively. Change in carrying angle was statistically significant (p = 0.002). There were 2 grade 1 pin tract infections and 1 diaphyseal fracture of humerus. Functional outcome was rated excellent in 7 patients and good in 1 patient. Ilizarov distraction osteogenesis is a valuable alternative in treatment of elbow deformities in children. The surgical technique is simple and correction is adjustable. Gradual correction prevents possible neurovascular complications and minimally invasive surgery produces less scarring. Compliance of patient and family is key factor in the success of the outcome. Level IV, therapeutic study. Copyright © 2016 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  11. Wearable Inertial Sensors Allow for Quantitative Assessment of Shoulder and Elbow Kinematics in a Cadaveric Knee Arthroscopy Model.

    PubMed

    Rose, Michael; Curtze, Carolin; O'Sullivan, Joseph; El-Gohary, Mahmoud; Crawford, Dennis; Friess, Darin; Brady, Jacqueline M

    2017-12-01

    To develop a model using wearable inertial sensors to assess the performance of orthopaedic residents while performing a diagnostic knee arthroscopy. Fourteen subjects performed a diagnostic arthroscopy on a cadaveric right knee. Participants were divided into novices (5 postgraduate year 3 residents), intermediates (5 postgraduate year 4 residents), and experts (4 faculty) based on experience. Arm movement data were collected by inertial measurement units (Opal sensors) by securing 2 sensors to each upper extremity (dorsal forearm and lateral arm) and 2 sensors to the trunk (sternum and lumbar spine). Kinematics of the elbow and shoulder joints were calculated from the inertial data by biomechanical modeling based on a sequence of links connected by joints. Range of motion required to complete the procedure was calculated for each group. Histograms were used to compare the distribution of joint positions for an expert, intermediate, and novice. For both the right and left upper extremities, skill level corresponded well with shoulder abduction-adduction and elbow prono-supination. Novices required on average 17.2° more motion in the right shoulder abduction-adduction plane than experts to complete the diagnostic arthroscopy (P = .03). For right elbow prono-supination (probe hand), novices required on average 23.7° more motion than experts to complete the procedure (P = .03). Histogram data showed novices had markedly more variability in shoulder abduction-adduction and elbow prono-supination compared with the other groups. Our data show wearable inertial sensors can measure joint kinematics during diagnostic knee arthroscopy. Range-of-motion data in the shoulder and elbow correlated inversely with arthroscopic experience. Motion pattern-based analysis shows promise as a metric of resident skill acquisition and development in arthroscopy. Wearable inertial sensors show promise as metrics of arthroscopic skill acquisition among residents. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  12. The correlation between proprioception and handwriting legibility in children

    PubMed Central

    Hong, So Young; Jung, Nam-Hae; Kim, Kyeong Mi

    2016-01-01

    [Purpose] This study investigated the association between proprioception, including joint position sense and kinetic sense, and handwriting legibility in healthy children. [Subjects and Methods] Assessment of joint position sense, kinetic sense, and handwriting legibility was conducted for 19 healthy children. Joint position sense was assessed by asking the children to flex their right elbow between 30° to 110° while blindfolded. The range of elbow movement was analyzed with Compact Measuring System 10 for 3D motion Analysis. Kinetic sense was assessed using the Sensory Integration and Praxis Test. The children were directed to write 30 words from the Korean alphabet, and the legibility of their handwriting was scored for form, alignment, space, size, and shape. To analyze the data, descriptive statistics and Spearman correlation analysis were conducted using IBM SPSS Statistics 20.0. [Results] There was significant negative correlation between handwriting legibility and Kinetic sense. A significant correlation between handwriting legibility and Joint position sense was not found. [Conclusion] This study showed that a higher Kinetic sense was associated with better legibility of handwriting. Further work is needed to determine the association of handwriting legibility and speed with Joint position sense of the elbow, wrist, and fingers. PMID:27821948

  13. Ipsilateral fracture dislocation of the shoulder and elbow: A case report and literature review

    PubMed Central

    Behr, Ian; Blint, Andy; Trenhaile, Scott

    2013-01-01

    Ipsilateral dislocation of the shoulder and elbow is an uncommon injury. A literature review identified nine previously described cases. We are reporting a unique case of ipsilateral posterior shoulder dislocation and anterior elbow dislocation along with concomitant intra-articular fractures of both joints. This is the first report describing this combination of injuries. Successful treatment generally occurs with closed reduction of ipsilateral shoulder and elbow dislocations, usually reducing the elbow first. When combined with a fracture at one or both locations, closed reduction of the dislocations in conjunction with appropriate fracture management can result in a positive functional outcome. PMID:26403884

  14. Effect of hammer mass on upper extremity joint moments.

    PubMed

    Balendra, Nilanthy; Langenderfer, Joseph E

    2017-04-01

    This study used an OpenSim inverse-dynamics musculoskeletal model scaled to subject-specific anthropometrics to calculate three-dimensional intersegmental moments at the shoulder, elbow and wrist while 10 subjects used 1 and 2 lb hammers to drive nails. Motion data were collected via an optoelectronic system and the interaction of the hammer with nails was recorded with a force plate. The larger hammer caused substantial increases (50-150%) in moments, although increases differed by joint, anatomical component, and significance of the effect. Moment increases were greater in cocking and strike/follow-through phases as opposed to swinging and may indicate greater potential for injury. Compared to shoulder, absolute increases in peak moments were smaller for elbow and wrist, but there was a trend toward larger relative increases for distal joints. Shoulder rotation, elbow varus-valgus and pronation-supination, and wrist radial-ulnar deviation and rotation demonstrated large relative moment increases. Trial and phase durations were greater for the larger hammer. Changes in moments and timing indicate greater loads on musculoskeletal tissues for an extended period with the larger hammer. Additionally, greater variability in timing with the larger hammer, particularly for cocking phase, suggests differences in control of the motion. Increased relative moments for distal joints may be particularly important for understanding disorders of the elbow and wrist associated with hammer use. Copyright © 2016 Elsevier Ltd. All rights reserved.

  15. The effect of glenosphere diameter in reverse shoulder arthroplasty on muscle force, joint load, and range of motion.

    PubMed

    Langohr, G Daniel G; Giles, Joshua W; Athwal, George S; Johnson, James A

    2015-06-01

    Little is known about the effects of glenosphere diameter on shoulder joint loads. The purpose of this biomechanical study was to investigate the effects of glenosphere diameter on joint load, load angle, and total deltoid force required for active abduction and range of motion in internal/external rotation and abduction. A custom, instrumented reverse shoulder arthroplasty implant system capable of measuring joint load and varying glenosphere diameter (38 and 42 mm) and glenoid offset (neutral and lateral) was implanted in 6 cadaveric shoulders to provide at least 80% power for all variables. A shoulder motion simulator was used to produce active glenohumeral and scapulothoracic motion. All implant configurations were tested with active and passive motion with joint kinematics, loads, and moments recorded. At neutral and lateralized glenosphere positions, increasing diameter significantly increased joint load (+12 ± 21 N and +6 ± 9 N; P < .01) and deltoid load required for active abduction (+9 ± 22 N and +11 ± 15 N; P < .02), whereas joint load angle was unaffected (P > .8). Passive internal rotation was reduced with increased diameter at both neutral and lateralized glenosphere positions (-6° ± 6° and -12° ± 6°; P < .002); however, external rotation was not affected (P > .05). At neutral glenosphere position, increasing diameter increased the maximum angles of both adduction (+1° ± 1°; P = .03) and abduction (+8° ± 9°; P < .05). Lateralization also increased abduction range of motion compared with neutral (P < .01). Although increasing glenosphere diameter significantly increased joint load and deltoid force, the clinical impact of these changes is presently unclear. Internal rotation, however, was reduced, which contradicts previous bone modeling studies, which we postulate is due to increased posterior capsular tension as it is forced to wrap around a larger 42 mm implant assembly. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  16. From reaching to reach-to-grasp: the arm posture difference and its implications on human motion control strategy.

    PubMed

    Li, Zhi; Milutinović, Dejan; Rosen, Jacob

    2017-05-01

    Reach-to-grasp arm postures differ from those in pure reaching because they are affected by grasp position/orientation, rather than simple transport to a position during a reaching motion. This paper investigates this difference via an analysis of experimental  data collected on reaching and reach-to-grasp motions. A seven-degree-of-freedom (DOFs) kinematic arm model with the swivel angle is used for the motion analysis. Compared to a widely used anatomical arm model, this model distinguishes clearly the four grasping-relevant DOFs (GR-DOFs) that are affected by positions and orientations of the objects to be grasped. These four GR-DOFs include the swivel angle that measures the elbow rotation about the shoulder-wrist axis, and three wrist joint angles. For each GR-DOF, we quantify position vs orientation task-relevance bias that measures how much the DOF is affected by the grasping position vs orientation. The swivel angle and forearm supination have similar bias, and the analysis of their motion suggests two hypotheses regarding the synergistic coordination of the macro- and micro-structures of the human arm (1) DOFs with similar task-relevance are synergistically coordinated; and (2) such synergy breaks when a task-relevant DOF is close to its joint limit without necessarily reaching the limit. This study provides a motion analysis method to reduce the control complexity for reach-to-grasp tasks, and suggests using dynamic coupling to coordinate the hand and arm of upper-limb exoskeletons.

  17. Reconstruction of the elbow and forearm for Ewing sarcoma of ulna: A new biological technique

    PubMed Central

    Puri, Ajay; Gulia, Ashish; Byregowda, Suman; Ramanujan, Vishnu

    2016-01-01

    Primary bone tumors around the elbow represent <1% of all the skeletal tumors. Surgery with or without adjuvant therapy (radiotherapy, chemotherapy) is the treatment of choice for malignant tumors. Reconstruction of the elbow and forearm in malignant tumors is challenging as it involves a complex interplay between multiple joints which need to be stabilized for the optimal functional outcome. We describe a new technique for the reconstruction of the elbow after resection of a proximal ulna tumor with articular radio-ulnar synostosis with the creation of a single bone forearm. We attempted to achieve a mobile elbow and stable wrist joint with the radio-ulnar union at the proximal articular surface of the ulna resulting in a single bone forearm. The procedure involves an oblique osteotomy preserving the olecranon process (after taking adequate margins based on oncological principles) and its articular cartilage along with the attachment of the triceps tendon. Then the radial head was partially denuded of its cartilage using a burr, leaving cartilage only on the volar side, and then fused to the remnant olecranon. Osteosynthesis was done using compression screw and tension band wiring. The advantages of this procedure are that the mobility at wrist and elbow are retained, it requires minimal hardware and allows for primary closure of the wound. PMID:27186061

  18. Elbow joint adductor moment arm as an indicator of forelimb posture in extinct quadrupedal tetrapods

    PubMed Central

    Fujiwara, Shin-ichi; Hutchinson, John R.

    2012-01-01

    Forelimb posture has been a controversial aspect of reconstructing locomotor behaviour in extinct quadrupedal tetrapods. This is partly owing to the qualitative and subjective nature of typical methods, which focus on bony articulations that are often ambiguous and unvalidated postural indicators. Here we outline a new, quantitatively based forelimb posture index that is applicable to a majority of extant tetrapods. By determining the degree of elbow joint adduction/abduction mobility in several tetrapods, the carpal flexor muscles were determined to also play a role as elbow adductors. Such adduction may play a major role during the stance phase in sprawling postures. This role is different from those of upright/sagittal and sloth-like creeping postures, which, respectively, depend more on elbow extensors and flexors. Our measurements of elbow muscle moment arms in 318 extant tetrapod skeletons (Lissamphibia, Synapsida and Reptilia: 33 major clades and 263 genera) revealed that sprawling, sagittal and creeping tetrapods, respectively, emphasize elbow adductor, extensor and flexor muscles. Furthermore, scansorial and non-scansorial taxa, respectively, emphasize flexors and extensors. Thus, forelimb postures of extinct tetrapods can be qualitatively classified based on our quantitative index. Using this method, we find that Triceratops (Ceratopsidae), Anhanguera (Pterosauria) and desmostylian mammals are categorized as upright/sagittally locomoting taxa. PMID:22357261

  19. Using the American alligator and a repeated-measures design to place constraints on in vivo shoulder joint range of motion in dinosaurs and other fossil archosaurs.

    PubMed

    Hutson, Joel D; Hutson, Kelda N

    2013-01-15

    Using the extant phylogenetic bracket of dinosaurs (crocodylians and birds), recent work has reported that elbow joint range of motion (ROM) studies of fossil dinosaur forearms may be providing conservative underestimates of fully fleshed in vivo ROM. As humeral ROM occupies a more central role in forelimb movements, the placement of quantitative constraints on shoulder joint ROM could improve fossil reconstructions. Here, we investigated whether soft tissues affect the more mobile shoulder joint in the same manner in which they affect elbow joint ROM in an extant archosaur. This test involved separately and repeatedly measuring humeral ROM in Alligator mississippiensis as soft tissues were dissected away in stages to bare bone. Our data show that the ROMs of humeral flexion and extension, as well as abduction and adduction, both show a statistically significant increase as flesh is removed, but then decrease when the bones must be physically articulated and moved until they separate from one another and/or visible joint surfaces. A similar ROM pattern is inferred for humeral pronation and supination. All final skeletonized ROMs were less than initial fully fleshed ROMs. These results are consistent with previously reported elbow joint ROM patterns from the extant phylogenetic bracket of dinosaurs. Thus, studies that avoid separation of complementary articular surfaces may be providing fossil shoulder joint ROMs that underestimate in vivo ROM in dinosaurs, as well as other fossil archosaurs.

  20. The use of joint mobilization to improve clinical outcomes in hand therapy: a systematic review of the literature.

    PubMed

    Heiser, Rick; O'Brien, Virginia H; Schwartz, Deborah A

    2013-01-01

    Systematic review. Joint mobilizations are used as an intervention for improving range of motion, decreasing pain and ultimately improving function in patients with a wide variety of upper extremity diagnoses. However, there are only a limited number of studies describing this treatment for conditions affecting the elbow, wrist, and hand. Furthermore, it is unclear as to the most effective joint mobilization technique utilized and the most beneficial functional outcomes gained. Examine the current evidence describing joint mobilizations for treatment of conditions of the elbow, wrist and hand, and offer informative practical clinical guidance. Twenty-two studies dated between 1980 and 2011 were included in the systematic review for analysis. The current evidence provides moderate support for the inclusion of joint mobilizations in the treatment of lateral epicondylalgia (LE). In particular, mobilization with movement as described by Mulligan is supported with evidence from nine randomized clinical trials as an effective technique for the treatment of pain. Other described techniques include those known as Kaltenborn, Cyriax physical therapy, and Maitland, but the evidence for these techniques is limited. There is also limited evidence for the joint mobilizations in the treatment of wrist and hand conditions. The current literature offers limited support for joint mobilizations of the wrist and hand, and moderate support for joint mobilizations of the elbow for LE. There is moderate support for mobilization with movement. . Copyright © 2013 Hanley & Belfus. Published by Elsevier Inc. All rights reserved.

  1. Complex mammary carcinoma with metastases to lymph nodes, subcutaneous tissue, and multiple joints in a dog.

    PubMed

    McCourt, Maggie R; Dieterly, Alexandra M; Mackey, Paige E; Lyon, Shane D; Rizzi, Theresa E; Ritchey, Jerry W

    2018-05-07

    An 8-year-old, intact female, mixed-breed dog presented to the Oklahoma State University Boren Veterinary Medical Teaching Hospital for evaluation of progressive lameness and joint effusion of multiple joints. Physical examination revealed joint effusion of the elbow, hock, and stifle joints bilaterally, enlarged left axillary and right popliteal lymph nodes, a subcutaneous mass over the left elbow, and a subcutaneous mass involving the left second and third mammary glands. Cytologic examination of the mammary mass, enlarged lymph nodes, and joint fluid from most affected joints revealed a monomorphic population of loosely cohesive neoplastic epithelial cells. The patient was humanely euthanized, and subsequent necropsy with histopathologic examination revealed a complex mammary carcinoma with metastases to enlarged lymph nodes, subcutaneous tissue over the left elbow, and the synovium of multiple joints. Immunohistochemical stains were performed and showed diffusely positive pan cytokeratin, CK8/18, and CK19 staining in the neoplastic luminal epithelial cells of the mammary carcinoma, synovium, and lymph nodes, and showed diffusely positive vimentin staining of the myoepithelial cells. Myoepithelial calponin positivity was diffuse in the mammary mass and lymph nodes but minimal in the synovium. Only the mammary mass showed p63 positivity. Metastatic mammary neoplasia is relatively common in dogs; however, metastasis to the synovium has only been reported once previously in the literature. This is the first case utilizing immunohistochemistry for confirmation and characterization of metastases. © 2018 American Society for Veterinary Clinical Pathology.

  2. Effects of electromyography-driven robot-aided hand training with neuromuscular electrical stimulation on hand control performance after chronic stroke.

    PubMed

    Rong, Wei; Tong, Kai Yu; Hu, Xiao Ling; Ho, Sze Kit

    2015-03-01

    An electromyography-driven robot system integrated with neuromuscular electrical stimulation (NMES) was developed to investigate its effectiveness on post-stroke rehabilitation. The performance of this system in assisting finger flexion/extension with different assistance combinations was evaluated in five stroke subjects. Then, a pilot study with 20-sessions training was conducted to evaluate the training's effectiveness. The results showed that combined assistance from the NMES-robot could improve finger movement accuracy, encourage muscle activation of the finger muscles and suppress excessive muscular activities in the elbow joint. When assistances from both NMES and the robot were 50% of their maximum assistances, finger-tracking performance had the best results, with the lowest root mean square error, greater range of motion, higher voluntary muscle activations of the finger joints and lower muscle co-contraction in the finger and elbow joints. Upper limb function improved after the 20-session training, indicated by the increased clinical scores of Fugl-Meyer Assessment, Action Research Arm Test and Wolf Motor Function Test. Muscle co-contraction was reduced in the finger and elbow joints reflected by the Modified Ashworth Scale. The findings demonstrated that an electromyography-driven NMES-robot used for chronic stroke improved hand function and tracking performance. Further research is warranted to validate the method on a larger scale. Implications for Rehabilitation The hand robotics and neuromuscular electrical stimulation (NMES) techniques are still separate systems in current post-stroke hand rehabilitation. This is the first study to investigate the combined effects of the NMES and robot on hand rehabilitation. The finger tracking performance was improved with the combined assistance from the EMG-driven NMES-robot hand system. The assistance from the robot could improve the finger movement accuracy and the assistance from the NMES could reduce the muscle co-contraction on finger and elbow joints. The upper limb functions were improved on chronic stroke patients after the pilot study of 20-session hand training with the combined assistance from the EMG-driven NMES-robot. The muscle spasticity on finger and elbow joints was reduced after the training.

  3. Long-term genetic selection reduced prevalence of hip and elbow dysplasia in 60 dog breeds

    PubMed Central

    Keller, G. G.; Famula, T. R.

    2017-01-01

    Canine hip dysplasia (CHD) and elbow dysplasia (ED) impact the health and welfare of all dogs. The first formally organized assessment scheme to improve canine health centered on reducing the prevalence of these orthopedic disorders. Phenotypic screening of joint conformation remains the currently available strategy for breeders to make selection decisions. The present study evaluated the efficacy of employing phenotypic selection on breed improvement of hips and elbows using the Orthopedic Foundation for Animals complete database spanning the 1970–2015 time period. Sixty breeds having more than 1000 unique hip evaluations and 500 elbow evaluations (1,056,852 and 275,129 hip and elbow records, respectively) were interrogated to derive phenotypic improvement, sex and age at time of assessment effects, correlation between the two joints, heritability estimates, estimated breeding values (EBV), and effectiveness of maternal/paternal selection. The data demonstrated that there has been overall improvement in hip and elbow conformation with a reduction in EBV for disease liability, although the breeds differed in the magnitude of the response to selection. Heritabilities also differed substantially across the breeds as did the correlation of the joints; in the absence of a universal association of these differences with breed size, popularity, or participation in screening, it appears that the breeds themselves vary in genetic control. There was subtle, though again breed specific, impact of sex and older ages on CHD and ED. There was greater paternal impact on a reduction of CHD. In the absence of direct genetic tests for either of these two diseases, phenotypic selection has proven to be effective. Furthermore, the data underscore that selection schemes must be breed specific and that it is likely the genetic profiles will be unique across the breeds for these two conditions. Despite the advances achieved with phenotypic selection, incorporation of EBVs into selection schemes should accelerate advances in hip and elbow improvement. PMID:28234985

  4. Long-term genetic selection reduced prevalence of hip and elbow dysplasia in 60 dog breeds.

    PubMed

    Oberbauer, A M; Keller, G G; Famula, T R

    2017-01-01

    Canine hip dysplasia (CHD) and elbow dysplasia (ED) impact the health and welfare of all dogs. The first formally organized assessment scheme to improve canine health centered on reducing the prevalence of these orthopedic disorders. Phenotypic screening of joint conformation remains the currently available strategy for breeders to make selection decisions. The present study evaluated the efficacy of employing phenotypic selection on breed improvement of hips and elbows using the Orthopedic Foundation for Animals complete database spanning the 1970-2015 time period. Sixty breeds having more than 1000 unique hip evaluations and 500 elbow evaluations (1,056,852 and 275,129 hip and elbow records, respectively) were interrogated to derive phenotypic improvement, sex and age at time of assessment effects, correlation between the two joints, heritability estimates, estimated breeding values (EBV), and effectiveness of maternal/paternal selection. The data demonstrated that there has been overall improvement in hip and elbow conformation with a reduction in EBV for disease liability, although the breeds differed in the magnitude of the response to selection. Heritabilities also differed substantially across the breeds as did the correlation of the joints; in the absence of a universal association of these differences with breed size, popularity, or participation in screening, it appears that the breeds themselves vary in genetic control. There was subtle, though again breed specific, impact of sex and older ages on CHD and ED. There was greater paternal impact on a reduction of CHD. In the absence of direct genetic tests for either of these two diseases, phenotypic selection has proven to be effective. Furthermore, the data underscore that selection schemes must be breed specific and that it is likely the genetic profiles will be unique across the breeds for these two conditions. Despite the advances achieved with phenotypic selection, incorporation of EBVs into selection schemes should accelerate advances in hip and elbow improvement.

  5. Snapping plicae associated with radiocapitellar chondromalacia.

    PubMed

    Antuna, S A; O'Driscoll, S W

    2001-05-01

    Painful snapping of the elbow joint is usually attributed to intra-articular loose bodies, instability, or medial dislocation of the triceps muscle over the medial epicondyle. We report our experience with 14 patients who were treated arthroscopically for snapping elbow that was found to be caused by hypertrophic synovial folds associated with radiocapitellar chondromalacia. Case series. The records of 14 patients who were treated arthroscopically for painful snapping elbows caused by intra-articular plicae were reviewed. There were 6 women and 8 men with an average age of 36 years (range, 27 to 48 years). Nine patients had had some type of trauma to the joint. Four patients had been previously diagnosed with lateral epicondylitis and 5 with intra-articular loose bodies. The average time from initial onset of symptoms to treatment was 13 months (range, 8 to 36 months). Average follow-up was 24 months (range, 6 to 66 months). All patients complained of painful snapping in the posterolateral or anterolateral aspect of the elbow. The snapping occurred between 90 degrees and 110 degrees of flexion with the forearm in pronation. In 7 patients, the snapping was reproducible by passively flexing the pronated elbow, which we refer to as the flexion-pronation test. At the time of arthroscopic surgery, all patients had a thickened synovial plica that would snap back and forward over the radial head, usually associated with a chondromalacic area on the radial head. Twelve patients had complete relief of their snapping after surgery. One patient in whom there was associated posterolateral rotatory elbow instability did not improve. One patient became asymptomatic for 4 years but then had recurrence of her symptoms, which persisted despite 2 subsequent arthroscopies. The presence of synovial plicae in the radiocapitellar joint must be considered in the differential diagnosis of painful snapping elbow. Arthroscopy confirms the diagnosis and allows excision of the plica.

  6. Virtual three-dimensional blackboard: three-dimensional finger tracking with a single camera

    NASA Astrophysics Data System (ADS)

    Wu, Andrew; Hassan-Shafique, Khurram; Shah, Mubarak; da Vitoria Lobo, N.

    2004-01-01

    We present a method for three-dimensional (3D) tracking of a human finger from a monocular sequence of images. To recover the third dimension from the two-dimensional images, we use the fact that the motion of the human arm is highly constrained owing to the dependencies between elbow and forearm and the physical constraints on joint angles. We use these anthropometric constraints to derive a 3D trajectory of a gesticulating arm. The system is fully automated and does not require human intervention. The system presented can be used as a visualization tool, as a user-input interface, or as part of some gesture-analysis system in which 3D information is important.

  7. Smartphone and Universal Goniometer for Measurement of Elbow Joint Motions: A Comparative Study

    PubMed Central

    Behnoush, Behnam; Tavakoli, Nasim; Bazmi, Elham; Nateghi Fard, Fariborz; Pourgharib Shahi, Mohammad Hossein; Okazi, Arash; Mokhtari, Tahmineh

    2016-01-01

    Background Universal goniometer (UG) is commonly used as a standard method to evaluate range of motion (ROM) as part of joint motions. It has some restrictions, such as involvement of both hands of the physician, leads to instability of hands and error. Nowadays smartphones usage has been increasing due to its easy application. Objectives The study was designed to compare the smartphone inclinometer-based app and UG in evaluation of ROM of elbow. Materials and Methods The maximum ROM of elbow in position of flexion and pronation and supination of forearm were examined in 60 healthy volunteers with UG and smartphone. Data were analyzed using SPSS (ver. 16) software and appropriate statistical tests were applied, such as paired t-test, ICC and Bland Altman curves. Results The results of this study showed high reliability and validity of smartphone in regarding UG with ICC > 0.95. The highest reliability for both methods was in elbow supination and the lowest was in the elbow flexion (0.84). Conclusions Smartphones due to ease of access and usage for the physician and the patient, may be good alternatives for UG. PMID:27625754

  8. Laser radiation in tennis elbow treatment: a new minimally invasive alternative

    NASA Astrophysics Data System (ADS)

    Paganini, Stefan; Thal, Dietmar R.; Werkmann, Klaus

    1998-01-01

    The epicondylitis humeri radialis (EHR) (tennis elbow), is a common disease in elbow joint pain syndromes. We treated patients with chronic pain for at least one year and no improvement with conservative or operative therapies with a new minimal invasive method, the EHR-Laser radiation (EHR- LR). With this method periepicondylar coagulations were applied to the trigger points of the patients. For this the previously established technique of facet joint coagulation with the Nd:Yag-laser was modified. In a follow-up study of between 6 weeks and 2 years all patients reported either a significant pain reduction or were symptom free. EHR-LR is a new method situated between conservative and surgical treatments for minimal invasive therapy of EHR. Several therapeutic rationales were discussed for the resulting pain reduction.

  9. Reconstruction of shifting elbow joint compliant characteristics during fast and slow movements.

    PubMed

    Latash, M L; Gottlieb, G L

    1991-01-01

    The purpose of this study was to experimentally investigate the applicability of the equilibrium-point hypothesis to the dynamics of single-joint movements. Subjects were trained to perform relatively slow (movement time 600-1000 ms) or fast (movement time 200-300 ms) single-joint elbow flexion movements against a constant extending torque bias. They were instructed to reproduce the same time pattern of central motor command for a series of movements when the external torque could slowly and unpredictably increase, decrease, or remain constant. For fast movements, the total muscle torque was calculated as a sum of external and inertial components. Analysis of the data allowed reconstruction of the elbow joint compliant characteristics at different times during execution of the learned motor command. "Virtual" trajectories of the movements, representing time-varying changes in a central control parameter, were reconstructed and compared with the "actual" trajectories. For slow movements, the actual trajectories lagged behind the virtual ones. There were no consistent changes in the joint stiffness during slow movements. Similar analysis of experiments without voluntary movements demonstrated a lack of changes in the central parameters, supporting the assumption that the subjects were able to keep the same central motor command in spite of externally imposed unexpected torque perturbations. For the fast movements, the virtual trajectories were N-shaped, and the joint stiffness demonstrated a considerable increase near the middle of the movement. These findings contradict an hypothesis of monotonic joint compliant characteristic translation at a nearly constant rate during such movements.

  10. Reconstruction of equilibrium trajectories and joint stiffness patterns during single-joint voluntary movements under different instructions.

    PubMed

    Latash, M L

    1994-01-01

    A method for reconstructing joint compliant characteristics during voluntary movements was applied to the analysis of oscillatory and unidirectional elbow flexion movements. In different series, the subjects were given one of the following instructions: (1) do not intervene voluntarily; (2) keep the trajectory; (3) in cases of perturbations, return back to the starting position as quickly as possible (only during unidirectional movements). Under the instruction 'keep trajectory', the apparent joint stiffness increased by 50% to 250%. During oscillatory movements, this was accompanied by a decrease in the maximal difference between the actual and equilibrium joint trajectories and, in several cases, led to a change in the phase relation between the two trajectories. The coefficients of correlation between joint torque and angle were very high (commonly, over 0.9) under the 'do not intervene' instruction. They dropped to about 0.6 under the 'keep trajectory' and to about 0.3 under the 'return back' instructions. Under these two instructions, the low values of the coefficients of correlation did not allow reconstruction of segments of equilibrium trajectories and joint stiffness values in all the subjects. The results provide further support for the lambda-version of the equilibrium-point hypothesis and for using the instruction 'do not intervene voluntarily' to obtain reproducible time patterns of the central motor command.

  11. Independent control of joint stiffness in the framework of the equilibrium-point hypothesis.

    PubMed

    Latash, M L

    1992-01-01

    In the framework of the equilibrium-point hypothesis, virtual trajectories and joint stiffness patterns have been reconstructed during two motor tasks practiced against a constant bias torque. One task required a voluntary increase in joint stiffness while preserving the original joint position. The other task involved fast elbow flexions over 36 degrees. Joint stiffness gradually subsided after the termination of fast movements. In both tasks, the external torque could slowly and unexpectedly change. The subjects were required not to change their motor commands if the torque changed, i.e. "to do the same no matter what the motor did". In both tasks, changes in joint stiffness were accompanied by unchanged virtual trajectories that were also independent of the absolute value of the bias torque. By contrast, the intercept of the joint compliant characteristic with the angle axis, r(t)-function, has demonstrated a clear dependence upon both the level of coactivation and external load. We assume that a template virtual trajectory is generated at a certain level of the motor hierarchy and is later scaled taking into account some commonly changing dynamic factors of the movement execution, for example, external load. The scaling leads to the generation of commands to the segmental structures that can be expressed, according to the equilibrium-point hypothesis, as changes in the thresholds of the tonic stretch reflex for corresponding muscles.

  12. In vivo and 3-dimensional functional anatomy of the anterior bundle of the medial collateral ligament of the elbow.

    PubMed

    Miyake, Junichi; Moritomo, Hisao; Masatomi, Takashi; Kataoka, Toshiyuki; Murase, Tsuyoshi; Yoshikawa, Hideki; Sugamoto, Kazuomi

    2012-08-01

    Although the anterior bundle of the medial collateral ligament (AMCL) is a critical stabilizer of the elbow joint, little information exists on in vivo and 3-dimensional functional anatomy of the AMCL. The purposes of this study were to investigate in vivo changes in the length of the AMCL during elbow flexion and to clarify the 3-dimensional functional anatomy of the AMCL. We created 3-dimensional models of the AMCL and bones from computed tomography data of 4 healthy elbows in 5 different elbow positions. The AMCL was subdivided into 9 ligaments. We calculated changes in lengths of ligaments during flexion and related ligament origins to the axis of rotation of the elbow joint. There were 4 uniquely configured isometric ligaments, where their origins aligned broadly along the course of the axis of rotation in the coronal plane. The medially originating ligaments inserted on the posterior portion of the tubercle of the coronoid process, whereas the laterally originating ligaments inserted on its anterior portion. There were 5 non-isometric ligaments, 3 of which had origins proximal to the axis and became taut only in extension and the other 2 having origins distal to the axis and becoming taut only in flexion. Isometric ligaments within the AMCL do not originate from a narrow area; rather, they originate from a broader area that extends more medially in the coronal plane than previously thought, which explains how the AMCL reconciles isometricity and robustness. The proximal and distal ligaments act as checkreins that work only at the limits of elbow motion. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  13. Simultaneous bilateral elbow dislocation with bilateral medial epicondyle fractures in a 13-year-old female gymnast with hyperlaxity

    PubMed Central

    Bauer, Stefan; Dunne, Ben; Whitewood, Colin

    2012-01-01

    Bilateral simultaneous elbow dislocations are extremely rare and have only been described in 12 cases. In the paediatric population unilateral elbow dislocations are rare with 3–6% of all elbow injuries and there are only few studies describing this injury exclusively in children. There is only one case report of a paediatric patient who sustained a simultaneous bilateral elbow dislocation with medial epicondyle fractures. We present a second paediatric case of simultaneous bilateral elbow dislocation with associated displaced bilateral medial epicondyle fractures in a gymnast with joint hyperlaxity (3 of 5 Wynne-Davies criteria) treated with closed reduction and short-term immobilisation (3 weeks). The patient returned to full trampoline gymnastics between 4 and 5 months postinjury and made an uneventful recovery. PMID:23234820

  14. Consequences of impact on arm (elbow and shoulder joints) caused by ball hitting, theoretical analysis

    NASA Astrophysics Data System (ADS)

    Negrea, Adina; Busuioceanu, Ioana Iuliana

    2018-02-01

    Present paper estimates the mechanics of the impact of a ball and a hand-arm, during the sports training using a classical model for the hand-arm system, avoiding the contribution of the coefficient of restitution. The results of this investigation are focused on the equations needed to find out theimpact reactions in elbow and shoulder joints, for different anthropometric data. Also, the computing of the position of mass centers and the moments of inertia for each constitutive part of hand-arm system is made.

  15. Hybrid external fixation in high-energy elbow fractures: a modular system with a promising future.

    PubMed

    Lerner, A; Stahl, S; Stein, H

    2000-12-01

    Severe, high-energy, periarticular elbow injuries producing a "floating joint" are a major surgical challenge. Their reconstruction and rehabilitation are not well documented. Therefore, the following reports our experience with treating such injuries caused by war wounds. Seven adults with compound open peri- and intra-articular elbow fractures were treated in hybrid ring tubular fixation frames. After debridement, bone stabilization, and neurovascular reconstructions, early controlled daily movements were started in the affected joint. These seven patients had together seven humeral, five radial, and six ulnar fractures. All fractures united at a median time of 180 days. No deep infection developed. The functional end results assessed by the Khalfayan functional score were excellent in two, good in one, and fair in four of these severely mangled upper extremities. None was amputated. The Mangled Extremity Severity Score has been shown to be unable to provide a reliable assessment for severe high-energy limb injuries surgically managed with the modular hybrid thin wire tubular external fixation system. This hybrid system is a very useful addition to the surgical armamentarium of orthopedic trauma surgeons. It both allows complex surgical reconstructions and reduces the incidence of deep infections in these heavily contaminated injuries. The hybrid circular (thin wire) external fixation system is very modular and may provide secure skeletal stabilization even in cases of severely comminuted juxta-articular fractures on both sides of the elbow joint (floating elbow) with severe damage to soft tissues. This fixation system allows individual fixation of forearm bone fractures, thus allowing the preservation of pronation-supination movements.

  16. Coronal plane radiographic evaluation of the single TightRope technique in the treatment of acute acromioclavicular joint injury.

    PubMed

    Yi, Young; Kim, Jeong Woo

    2015-10-01

    This study aimed to demonstrate the technical aspects of the single TightRope (Arthrex, Naples, FL, USA) procedure for acute acromioclavicular-coracoclavicular joint dislocation, identify the predictive factors influencing its outcome, and assess and validate the significance of specific radiologic parameters. We reviewed true anteroposterior shoulder radiographs of 62 consecutive patients who had undergone surgical reconstruction using TightRope for an acute acromioclavicular-coracoclavicular injury. All patients were followed up for at least 12 months between October 2009 and March 2012 and were divided into dissociated or nondissociated groups according to their surgical outcome. We measured the clavicle tunnel anteroposterior angle, distal clavicular tunnel placement, and tunnel-to-medial coracoid ratio, and compared the parameters in each group after a satisfactory intraclass correlation coefficient reliability test result. The angles of patients in the dissociated group were more acute compared with the angles of those in the nondissociated group, which were perpendicular, as verified statistically using the paired t test. The difference in the distal clavicular tunnel placement and tunnel-to-medial coracoid ratio between the groups was not significant. Therefore, tunnel placement is not influenced by coracoclavicular dissociation. The clavicle tunnel anteroposterior angle can be used as a predictor of surgical outcome in coracoclavicular augmentation surgery. The surgeon should strive to place a perpendicular hole from the clavicle to the coracoid process for the TightRope fixation to enable a successful reconstruction of the acute acromioclavicular-coracoclavicular injury. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  17. Does Excision of Heterotopic Ossification of the Elbow Result in Satisfactory Patient-Rated Outcomes?

    PubMed

    Sandeep, K N; Suresh, G; Gopisankar, B; Abhishek, N; Sujiv, A

    2017-03-01

    Treatment of heterotopic ossification (HO) of the elbow is challenging and fraught with complications. Patients who sustain direct trauma to the elbow joint, the central nervous system, and thermal burns are at increased risk for development of HO. There is a paucity of studies and reports on patient's self-evaluation after the excision of the heterotopic ossification. This retrospective study assessed outcomes after excision of heterotopic ossification around the elbow in a cohort of ten patients operated from 2012 to 2015. The outcome assessment was done by the Mayo Elbow Performance index (MEPI) and the American Shoulder and Elbow Surgeons-Elbow score (ASES-E scores). The mean follow-up was 18.11 months after the operation. The Mayo Elbow Performance Score was excellent in two elbows, good in six and fair in two. The mean gain in flexion-extension arc after excision of HO was 80 degrees. All of the patients had residual flexion deformity postoperatively. Eight of the nine patients were able to do activities requiring flexion at final follow-up. Excision of HO around the elbow is associated with satisfactory patient-rated outcomes in spite of failure to regain full range of motion.

  18. Assessment of posture and joint movements of the upper limbs of patients after mastectomy and lymphadenectomy

    PubMed Central

    Haddad, Cinira Assad Simão; Saad, Marcelo; Perez, Maria del Carmen Janeiro; Miranda, Fausto

    2013-01-01

    ABSTRACT Objective: To evaluate alterations in posture and range of motion of the upper limbs in women after mastectomy and lymphadenectomy, submitted to radiotherapy as adjuvant treatment. Methods: Two groups were evaluated: 16 post-mastectomy women with lymphedema of the upper limb and 14 post-mastectomy women without lymphedema. Patients were submitted to analysis made by software, one for posture and the other to measure ranges of movement of the shoulder, elbow, and wrists. The results obtained were compared between the right and left sides, and operated and non-operated sides, and then were submitted to statistical tests. Results: Both groups presented with anteriorization of the trunk. The women with lymphedema had head rotation to the right, protrusion of the left shoulder, and trunk inclination angle smaller on the operated side, besides bilateral elevation of the scapula when compared to the group with no lymphedema. Changes in range of motion were also smaller on the operated side in terms of flexion, abduction, and external rotation of the shoulder for all women, and for those with lymphedema, elbow extension and wrist flexion had a smaller range of motion. Conclusion: Women submitted to mastectomy presented with asymmetries and modifications in posture, and lymphedema seemed to worsen this condition. Additionally, they had deficits in range of motion in the shoulders on the operated side. Women with lymphedema also showed deficits in the elbows and wrist. PMID:24488379

  19. The responses of muscle spindles to small, slow movements in passive muscle and during fusimotor activity.

    PubMed

    Wise, A K; Gregory, J E; Proske, U

    1999-03-06

    We have previously shown that movement detection thresholds at the human elbow joint were less than a degree of joint rotation in the passive limb but were higher if they were measured while subjects co-contracted elbow muscles [A.K. Wise, J.E. Gregory, U. Proske, J. Physiol., 508 (1998) 325-330]. Here we report observations on the responses of muscle spindles of the soleus muscle of the anaesthetised cat to determine their ability to signal small length changes in the passive muscle and during a contraction, under conditions resembling those of the human experiments. After appropriate conditioning of the muscle to control for history effects, primary endings of muscle spindles showed thresholds to ramp stretch at 20 micrometers s-1 of between less than 5 micrometers and 15 micrometers, which translates to 0.05 degrees -0.15 degrees of human elbow joint rotation. Thresholds were much higher following conditioning to introduce slack in the muscle. Since during a voluntary contraction there is likely to be alpha:gamma co-activation, responses of spindles were also recorded during slow stretches (100 micrometers at 20 micrometers s-1) during static fusimotor stimulation, dynamic fusimotor stimulation, combined fusimotor stimulation and fusimotor plus skeletomotor stimulation. Invariably, responses to passive stretch were larger than during motor stimulation. It is concluded that spindles are sensitive enough to signal fractions of a degree of elbow joint rotation and that the rise in threshold observed during a voluntary contraction may be accounted for by the actions of fusimotor and skeletomotor axons on spindle stretch responses. Copyright 1999 Elsevier Science B.V.

  20. Radiosynovectomy in haemophilic synovitis of elbows and ankles: Is the effectiveness of yttrium-90 and rhenium-186 different?

    PubMed

    Rodriguez-Merchan, E C; De La Corte-Rodriguez, H

    2016-04-01

    Radiosynovectomy (RS) reduces the number of haemarthroses and the synovial size in chronic haemophilic synovitis. The purpose of this study was to quantitatively compare the effectiveness of two types of RS (yttrium-90 vs. rhenium-186) in terms of the objective improvement of haemarthroses and synovial size. Seventy RSs were performed in 70 joints (44 elbows, 26 ankles) of 70 haemophiliacs diagnosed with chronic synovitis. Yttrium-90 was used in 21 joints and rhenium-186 was used in 49 joints. The mean patient age was 20.61 years. RS resulted in significant improvement in the three variables studied (six months before RS vs. six months after RS), namely in the number of episodes of haemarthrosis (67.8% improvement); the size of the synovium as measured by means of a clinical scale (43.8% improvement) and imaging techniques in millimetres (26.7% improvement). We did not find significant statistical differences between yttrium-90 and rhenium-186 regarding their efficacy. No correlation was found between the results and other variables: age, joint (ankle or elbow), presence or absence of radiological involvement, type of haemophilia (A or B), grade of haemophilia (mild, moderate or severe), previous haematological treatment (on demand or prophylaxis), and the presence or absence of inhibitor Yttrium-90 RS and rhenium-186 RS were equally effective in reducing the number of haemarthroses and the size of the synovium in ankles and elbows in the short-term (6 months). No correlation was found between the results and other patients' characteristics. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Improved orthopedic arm joint

    NASA Technical Reports Server (NTRS)

    Dane, D. H.

    1971-01-01

    Joint permits smooth and easy movement of disabled arm and is smaller, lighter and less expensive than previous models. Device is interchangeable and may be used on either arm at the shoulder or at the elbow.

  2. Disruption of spatial organization and interjoint coordination in Parkinson's disease, progressive supranuclear palsy, and multiple system atrophy.

    PubMed

    Leiguarda, R; Merello, M; Balej, J; Starkstein, S; Nogues, M; Marsden, C D

    2000-07-01

    Patients with basal ganglia diseases may exhibit ideomotor apraxia. To define the nature of the impairment of the action production system, we studied a repetitive gesture of slicing bread by three-dimensional computergraphic analysis in eight nondemented patients with Parkinson's disease in the "on" state, five with progressive supranuclear palsy and four with multiple system atrophy. Two patients with Parkinson's disease and two with progressive supranuclear palsy showed ideomotor apraxia for transitive movements on standard testing. A Selspott II system was used for kinematic analysis of wrist trajectories and angular motions of the shoulder and elbow joints. Patients with Parkinson's disease, progressive supranuclear palsy, and even some with multiple system atrophy exhibited kinematic deficits in the spatial precision of movement and velocity-curvature relationships; in addition, they failed to maintain proper angle/angle relationships and to apportion their relative joint amplitudes normally. Spatial disruption of wrist trajectories was more severe in patients with ideomotor apraxia. We posit that the basal ganglia are part of the parallel parieto-frontal circuits devoted to sensorimotor integration for object-oriented behavior. The severity and characteristics of spatial abnormalities of a transitive movement would therefore depend on the location and distribution of the pathologic process within these circuits.

  3. Developing a multi-joint upper limb exoskeleton robot for diagnosis, therapy, and outcome evaluation in neurorehabilitation.

    PubMed

    Ren, Yupeng; Kang, Sang Hoon; Park, Hyung-Soon; Wu, Yi-Ning; Zhang, Li-Qun

    2013-05-01

    Arm impairments in patients post stroke involve the shoulder, elbow and wrist simultaneously. It is not very clear how patients develop spasticity and reduced range of motion (ROM) at the multiple joints and the abnormal couplings among the multiple joints and the multiple degrees-of-freedom (DOF) during passive movement. It is also not clear how they lose independent control of individual joints/DOFs and coordination among the joints/DOFs during voluntary movement. An upper limb exoskeleton robot, the IntelliArm, which can control the shoulder, elbow, and wrist, was developed, aiming to support clinicians and patients with the following integrated capabilities: 1) quantitative, objective, and comprehensive multi-joint neuromechanical pre-evaluation capabilities aiding multi-joint/DOF diagnosis for individual patients; 2) strenuous and safe passive stretching of hypertonic/deformed arm for loosening up muscles/joints based on the robot-aided diagnosis; 3) (assistive/resistive) active reaching training after passive stretching for regaining/improving motor control ability; and 4) quantitative, objective, and comprehensive neuromechanical outcome evaluation at the level of individual joints/DOFs, multiple joints, and whole arm. Feasibility of the integrated capabilities was demonstrated through experiments with stroke survivors and healthy subjects.

  4. Influence of smartphone use styles on typing performance and biomechanical exposure.

    PubMed

    Ko, Ping-Hsin; Hwang, Yaw-Huei; Liang, Huey-Wen

    2016-06-01

    Twenty-seven subjects completed 2-min typing tasks using four typing styles: right-hand holding/typing (S-thumb) and two-hand typing at three heights (B-low, B-mid and B-high). The styles had significant effects on typing performance, neck and elbow flexion and muscle activities of the right trapezius and several muscles of the right upper limb (p < 0.0001 by repeated-measure analysis of variance). The subjects typed the fewest words (error-adjusted characters per minute: 78) with the S-thumb style. S-thumb style resulted in similar flexion angles of the neck, elbow and wrist, but significantly increased muscle activities in all tested muscles compared with the B-mid style. Holding the phone high or low reduced the flexion angles of the neck and right elbow compared with the B-mid style, but the former styles increased the muscle activity of the right trapezius. Right-hand holding/typing was not a preferable posture due to high muscle activities and slow typing speed. Practitioner Summary: Right-hand holding/typing was not favoured, due to increased muscle activities and slower typing speed. Holding the phone high or low reduced the flexion angles of the neck and right elbow, but the former styles increased the muscle activity of the right trapezius compared with holding the phone at chest level.

  5. Female Age-Related Differences in Biomechanics and Muscle Activity During Descents on the Outstretched Arms.

    PubMed

    Lattimer, Lauren J; Lanovaz, Joel L; Farthing, Jonathan P; Madill, Stéphanie; Kim, Soo; Robinovitch, Stephen; Arnold, Cathy

    2017-07-01

    The purposes of this study were to examine female age differences in: (1) upper extremity (UE) and trunk muscle activity, elbow joint moment, loading force, and UE energy absorption during a controlled forward body descent; and (2) UE muscle strength. Twenty young (mean 24.8 ± 3.4 years) and 20 older (68.4 ± 5.7 years) women were assessed via dynamometry for isometric, concentric, and eccentric UE strength and performed forward descents on force plates at three body lean angles (60°, 45°, and 30° from horizontal). Significant differences (p < .05) were found for muscle strength, biomechanics, and muscle activity. Concentric UE strength averaged 15% lower in older women. At 30° body lean, older women absorbed less energy. Older women had greater biceps brachii activation and less external oblique activation at all body lean angles. Age differences in muscle strength, activation, and energy absorption may contribute to fall-related injury risk.

  6. The effect of ball impact location on racket and forearm joint angle changes for one-handed tennis backhand groundstrokes.

    PubMed

    King, Mark; Hau, Agnes; Blenkinsop, Glen

    2017-07-01

    Recreational tennis players tend to have higher incidence of tennis elbow, and this has been hypothesised to be related to one-handed backhand technique and off-centre ball impacts on the racket face. This study aimed to investigate for a range of participants the effect of off-longitudinal axis and off-lateral axis ball-racket impact locations on racket and forearm joint angle changes immediately following impact in one-handed tennis backhand groundstrokes. Three-dimensional racket and wrist angular kinematic data were recorded for 14 university tennis players each performing 30 "flat" one-handed backhand groundstrokes. Off-longitudinal axis ball-racket impact locations explained over 70% of the variation in racket rotation about the longitudinal axis and wrist flexion/extension angles during the 30 ms immediately following impact. Off-lateral axis ball-racket impact locations had a less clear cut influence on racket and forearm rotations. Specifically off-longitudinal impacts below the longitudinal axis forced the wrist into flexion for all participants with there being between 11° and 32° of forced wrist flexion for an off-longitudinal axis impact that was 1 ball diameter away from the midline. This study has confirmed that off-longitudinal impacts below the longitudinal axis contribute to forced wrist flexion and eccentric stretch of the wrist extensors and there can be large differences in the amount of forced wrist flexion from individual to individual and between strokes with different impact locations.

  7. Prediction of elbow joint contact mechanics in the multibody framework.

    PubMed

    Rahman, Munsur; Cil, Akin; Stylianou, Antonis P

    2016-03-01

    Computational multibody musculoskeletal models of the elbow joint that are capable of simultaneous and accurate predictions of muscle and ligament forces, along with cartilage contact mechanics can be immensely useful in clinical practice. As a step towards producing a musculoskeletal model that includes the interaction between cartilage and muscle loading, the goal of this study was to develop subject-specific multibody models of the elbow joint with discretized humerus cartilage representation interacting with the radius and ulna cartilages through deformable contacts. The contact parameters for the compliant contact law were derived using simplified elastic foundation contact theory. The models were then validated by placing the model in a virtual mechanical tester for flexion-extension motion similar to a cadaver experiment, and the resulting kinematics were compared. Two cadaveric upper limbs were used in this study. The humeral heads were subjected to axial motion in a mechanical tester and the resulting kinematics from three bones were recorded for model validation. The maximum RMS error between the predicted and measured kinematics during the complete testing cycle was 2.7 mm medial-lateral translation and 9.7° varus-valgus rotation of radius relative to humerus (for elbow 2). After model validation, a lateral ulnar collateral ligament (LUCL) deficient condition was simulated and, contact pressures and kinematics were compared to the intact elbow model. A noticeable difference in kinematics, contact area, and contact pressure were observed for LUCL deficient condition. LUCL deficiency induced higher internal rotations for both the radius and ulna during flexion and an associated medial shift of the articular contact area. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  8. (Un)importance of physical therapy in treatment of displaced supracondylar humerus fractures in children.

    PubMed

    Ducic, Sinisa; Bumbasirevic, Marko; Radlovic, Vladimir; Bukumiric, Zoran; Bukva, Bojan; Abramovic, Dusan

    2015-09-01

    Elbow joint stiffness is a common complication following supracondylar humerus fractures. In prospective study, dynamics of establishing a full range of motion in the elbow joint following the treatment of supracondylar humerus fractures were assessed, together with the effects of physical therapy on improvement in the range of motion. Two groups of patients were observed. Physical therapy was administered to the first group, comprised of 25 patients. The second group, comprised of 28 patients, underwent no physical therapy. In the first few months following treatment, the range of motion was significantly greater in the patients who had undergone physical therapy, but after 12 months, the range of motion was almost equal in the two groups. This study has shown that it takes about 12 months to establish a full range of motion after the injury, and that it is not necessary to apply physical therapy in patients with elbow fractures.

  9. KAPS (kinematic assessment of passive stretch): a tool to assess elbow flexor and extensor spasticity after stroke using a robotic exoskeleton.

    PubMed

    Centen, Andrew; Lowrey, Catherine R; Scott, Stephen H; Yeh, Ting-Ting; Mochizuki, George

    2017-06-19

    Spasticity is a common sequela of stroke. Traditional assessment methods include relatively coarse scales that may not capture all characteristics of elevated muscle tone. Thus, the aim of this study was to develop a tool to quantitatively assess post-stroke spasticity in the upper extremity. Ninety-six healthy individuals and 46 individuals with stroke participated in this study. The kinematic assessment of passive stretch (KAPS) protocol consisted of passive elbow stretch in flexion and extension across an 80° range in 5 movement durations. Seven parameters were identified and assessed to characterize spasticity (peak velocity, final angle, creep (or release), between-arm peak velocity difference, between-arm final angle, between-arm creep, and between-arm catch angle). The fastest movement duration (600 ms) was most effective at identifying impairment in each parameter associated with spasticity. A decrease in peak velocity during passive stretch between the affected and unaffected limb was most effective at identifying individuals as impaired. Spasticity was also associated with a decreased passive range (final angle) and a classic 'catch and release' as seen through between-arm catch and creep metrics. The KAPS protocol and robotic technology can provide a sensitive and quantitative assessment of post-stroke elbow spasticity not currently attainable through traditional measures.

  10. Active upper limb prosthesis based on natural movement trajectories.

    PubMed

    Ramírez-García, Alfredo; Leija, Lorenzo; Muñoz, Roberto

    2010-03-01

    The motion of the current prostheses is sequential and does not allow natural movements. In this work, complex natural motion patterns from a healthy upper limb were characterized in order to be emulated for a trans-humeral prosthesis with three degrees of freedom at the elbow. Firstly, it was necessary to define the prosthesis workspace, which means to establish a relationship using an artificial neural network (ANN), between the arm-forearm (3-D) angles allowed by the prosthesis, and its actuators length. The 3-D angles were measured between the forearm and each axis of the reference system attached at the elbow. Secondly, five activities of daily living (ADLs) were analyzed by means of the elbow flexion (EF), the forearm prono-supination (FPS) and the 3-D angles, from healthy subjects, by using a video-based motion analysis system. The 3-D angles were fed to the prosthesis model (ANN) in order to analyze which ADLs could be emulated by the prosthesis. As a result, a prosthesis kinematics approximation was obtained. In conclusion, in spite of the innovative mechanical configuration of the actuators, it was possible to carry out only three of the five ADLs considered. Future work will include improvement of the mechanical configuration of the prosthesis to have greater range of motion.

  11. Surrogate: A Body-Dexterous Mobile Manipulation Robot with a Tracked Base

    NASA Technical Reports Server (NTRS)

    Hebert, Paul (Inventor); Borders, James W. (Inventor); Hudson, Nicolas H. (Inventor); Kennedy, Brett A. (Inventor); Ma, Jeremy C. (Inventor); Bergh, Charles F. (Inventor)

    2018-01-01

    Robotics platforms in accordance with various embodiments of the invention can be utilized to implement highly dexterous robots capable of whole body motion. Robotics platforms in accordance with one embodiment of the invention include: a memory containing a whole body motion application; a spine, where the spine has seven degrees of freedom and comprises a spine actuator and three spine elbow joints that each include two spine joint actuators; at least one limb, where the at least one limb comprises a limb actuator and three limb elbow joints that each include two limb joint actuators; a tracked base; a connecting structure that connects the at least one limb to the spine; a second connecting structure that connects the spine to the tracked base; wherein the processor is configured by the whole body motion application to move the at least one limb and the spine to perform whole body motion.

  12. A clinically oriented comprehensive pictorial review of canine elbow anatomy.

    PubMed

    Constantinescu, Gheorghe M; Constantinescu, Ileana A

    2009-02-01

    The clinically oriented canine elbow anatomy in its complexity earned a high importance in surgery especially after multiple imaging modalities have been used in the benefit of diagnosis and treatment of canine elbow disorders. The bony, joint, and muscular structures, the arteries, the veins and the nerves supplying the elbow are described and illustrated in textbooks and atlases in the context of the comparative anatomy. Nevertheless, there is no publication focused on all of these structures described together from the skin to the bones in a systematic and topographic order, nor through cross and/or sagittal and coronal sections. The figures used in this article are original and drawn after dissection, cross, sagittal, and coronal sections of the elbow structures. The sections are correlated to the multiple imaging modalities shown in the next article.

  13. Failure Behavior of Elbows with Local Wall Thinning

    NASA Astrophysics Data System (ADS)

    Lee, Sung-Ho; Lee, Jeong-Keun; Park, Jai-Hak

    Wall thinning defect due to corrosion is one of major aging phenomena in carbon steel pipes in most plant industries, and it results in reducing load carrying capacity of the piping components. A failure test system was set up for real scale elbows containing various simulated wall thinning defects, and monotonic in-plane bending tests were performed under internal pressure to find out the failure behavior of them. The failure behavior of wall-thinned elbows was characterized by the circumferential angle of thinned region and the loading conditions to the piping system.

  14. Operative treatment of lateral humeral condyle fractures in children.

    PubMed

    Wirmer, Johannes; Kruppa, Christian; Fitze, Guido

    2012-08-01

    The operative treatment of lateral humeral condyle fractures in children remains controversial. The result of incorrectly treated fractures may lead to complications such as pseudoarthrosis and severe deformity, with considerable functional and cosmetic restrictions. The aim of this study was to determine whether operative treatment of lateral humeral condyle fractures in children using Screw-wires (Orthofix GmbH, Ottobrunn, Germany) has any advantage over treatment with Kirschner wires ("K-wires") (aap-Implantate AG, Berlin, Germany). These results were then compared with operative treatment using lag-screw osteosynthesis. We treated surgically 76 cases of fracture of the lateral humeral condyle in children at the Department of Pediatric Surgery in Dresden between 1989 to 2002 and 2004 to 2008, from which 42 were available for follow-up examination. Within this group, there were seven children that were followed-up twice (in 1996 to 2002). Of these, 21 patients were treated with Screw-wires, and another 21 had K-wires inserted. The results were evaluated according to the Dhillon criteria. Only seven patients (17%) had a fair result in the overall grading according to the Dhillon criteria, four after K-wire and three after Screw-wire osteosyntheses. The remaining patients scored good to excellent results. There were no pseudoarthroses. Six patients (14%) had a varisation in the carrying angle between 10 and 16 degrees (three each procedure), and 15 patients (36%) had no difference in the carrying angle at all. Of these 15 patients, 10 were treated with Screw-wire osteosynthesis. Only one patient (2.4%) had a deficit of more than 10 degrees in elbow joint flexion, while only two (4.8%, one each procedure) had a deficit of more than 10 degrees in elbow joint extension, compared with the uninjured arm. Our results demonstrate that the employment of Screw-wire osteosynthesis is superior to the use of K-wires concerning the carrying angle while scoring alike on the other criteria. Compared with the use of lag screws, both treatments (K-wire and Screw-wire osteosyntheses) bear less risk of nonvascular necrosis or small metaphyseal fragment rupture, by comparable results in the overall outcome. Regarding the long-term development of healed fractures, changes in the carrying angle and the range of motion are of a small degree. Considering the results of this study, we recommend the use of Screw-wire osteosynthesis in the operative treatment of lateral humeral condyle fractures in children. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Relationship Between the Range of Motion and Isometric Strength of Elbow and Shoulder Joints and Ball Velocity in Women Team Handball Players.

    PubMed

    Schwesig, René; Hermassi, Souhail; Wagner, Herbert; Fischer, David; Fieseler, Georg; Molitor, Thomas; Delank, Karl-Stefan

    2016-12-01

    Schwesig, R, Hermassi, S, Wagner, H, Fischer, D, Fieseler, G, Molitor, T, and Delank, K-S. Relationship between the range of motion and isometric strength of elbow and shoulder joints and ball velocity in women team handball players. J Strength Cond Res 30(12): 3428-3435, 2016-The aims of this study were to investigate relationships between isometric strength and range of motion (ROM) of shoulder and elbow joints and compare 2 different team handball throwing techniques in women team handball. Twenty highly experienced women team handball players (age: 20.7 ± 2.9 years; body mass: 68.4 ± 6.0 kg; and height: 1.74 ± 0.06 m) participated in this study. The isometric strength (hand-held dynamometer) and ROM (goniometer) of shoulder and elbow joints were measured at the beginning of the preseasonal training. After clinical examination, the subjects performed 3 standing throws with run-up (10 m) and 3 jump throws over a hurdle (0.20 m). The mean ball velocity was calculated from 3 attempts and measured using a radar gun. The results showed that the ball velocity of the standing throw with run-up (vST) was significantly higher than that of the jump throw (vJT) (25.5 ± 1.56 vs. 23.2 ± 1.31 m·s; p < 0.001). Therefore, significant playing position effects (p = 0.021) were only found for ST. Goalkeepers (n = 2) had the lowest (22.6 ± 0.04 m·s) and backcourt players (n = 9), the highest (26.1 ± 1.36 m·s) vST. The retroversion strength in the shoulder was the only parameter with relevant correlations to both throws (vST: r = 0.52, and vJT: r = 0.43). Other relevant relationships to vJT were found for adduction strength shoulder (r = 0.55) and ROM flexion elbow (r = -0.54). The vST was only correlated to the glenohumeral internal rotation deficit. As a consequence, strength is more important than the ROM, and in addition to this, the shoulder, compared with the elbow, has a greater influence on the vST in highly experienced women team handball players.

  16. Plasticity in cortical motor upper-limb representation following stroke and rehabilitation: two longitudinal multi-joint FMRI case-studies.

    PubMed

    Stark, A; Meiner, Z; Lefkovitz, R; Levin, N

    2012-04-01

    Motor dysfunction and recovery following stroke and rehabilitation are associated with primary motor cortex plasticity. To better track these effects we studied two patients with sub-acute sub-cortical stroke causing hemiparesis, who underwent an effective behavioral treatment termed Constraint Induced Movement Therapy (CIMT). The therapy involves 2 weeks of intensive motor training of the hemiparetic limb coupled with immobilization of the unaffected limb. The study included a longitudinal series of clinical evaluations and fMRI scans, before and after the treatment. The fMRI task included wrist, elbow, or ankle movements. Activity in the M1 upper-limb region of control subjects was stable, strictly contralateral, and similar in amplitude for elbow and wrist movements. These findings reflect the well-known contralateral motor control and support the idea of overlapping representations of adjacent joints in M1. In both patients, pre-CIMT activation patterns in M1 were tested twice and did not change significantly, were contralateral, and included elbow-wrist differences. Following CIMT, the clinical condition of both patients improved and three fMRI-explored prototypes were found: First, cluster position remained constant; Second, ipsilateral activity appeared in the unaffected hemispheres during hemiparetic movements; Third, patient-specific elbow-wrist inter and intra hemispheric differences were modified. All effects were long-lasting. We suggest that overlapping representations of adjacent joints contributed to the cortical plasticity observed following CIMT. Our findings should be confirmed by studying larger groups of homogeneous patients. Nevertheless, this study introduces multi-joint imaging studies and shows that it is both possible and valuable to carry it out in stroke patients.

  17. Motor impairments related to brain injury timing in early hemiparesis. Part II: abnormal upper extremity joint torque synergies.

    PubMed

    Sukal-Moulton, Theresa; Krosschell, Kristin J; Gaebler-Spira, Deborah J; Dewald, Julius P A

    2014-01-01

    Extensive neuromotor development occurs early in human life, and the timing of brain injury may affect the resulting motor impairment. In Part I of this series, it was demonstrated that the distribution of weakness in the upper extremity depended on the timing of brain injury in individuals with childhood-onset hemiparesis. The goal of this study was to characterize how timing of brain injury affects joint torque synergies, or losses of independent joint control. Twenty-four individuals with hemiparesis were divided into 3 groups based on the timing of their injury: before birth (PRE-natal, n = 8), around the time of birth (PERI-natal, n = 8), and after 6 months of age (POST-natal, n = 8). Individuals with hemiparesis and 8 typically developing peers participated in maximal isometric shoulder, elbow, wrist, and finger torque generation tasks while their efforts were recorded by a multiple degree-of-freedom load cell. Motor output in 4 joints of the upper extremity was concurrently measured during 8 primary torque generation tasks to quantify joint torque synergies. There were a number of significant coupling patterns identified in individuals with hemiparesis that differed from the typically developing group. POST-natal differences were most noted in the coupling of shoulder abductors with elbow, wrist, and finger flexors, while the PRE-natal group demonstrated significant distal joint coupling with elbow flexion. The torque synergies measured provide indirect evidence for the use of bulbospinal pathways in the POST-natal group, while those with earlier injury may use relatively preserved ipsilateral corticospinal motor pathways.

  18. Effect of Anconeus Muscle Blocking on Elbow Kinematics: Electromyographic, Inertial Sensors and Finite Element Study.

    PubMed

    Miguel-Andres, Israel; Alonso-Rasgado, Teresa; Walmsley, Alan; Watts, Adam C

    2017-03-01

    The specific contribution of the anconeus muscle to elbow function is still uncertain. This study aimed to investigate the effect on elbow kinematics and kinetics of blocking anconeus using lidocaine. Ten healthy volunteers performed experimental trials involving flexion-extension and supination-pronation movements in horizontal and sagittal planes. Inertial sensors and surface electromyography were used to record elbow kinematics and kinetics and electrical activity from the anconeus, biceps and triceps brachii before and after blocking anconeus. Moreover, a finite element model of the elbow was created to further investigate the contribution of anconeus to elbow kinematics. The electrical activity results from the trials before blocking clearly indicated that activity of anconeus was increased during extension, suggesting that it behaves as an extensor. However, blocking anconeus had no effect on the elbow kinematics and kinetics, including the angular velocity, net torque and power of the joint. The electrical activity of the biceps and triceps brachii did not alter significantly following anconeus blocking. These results suggest that anconeus is a weak extensor, and the relative small contribution of anconeus to extension before blocking was compensated by triceps brachii. The finite element results indicated that anconeus does not contribute significantly to elbow kinematics.

  19. Effects of the racket polar moment of inertia on dominant upper limb joint moments during tennis serve.

    PubMed

    Rogowski, Isabelle; Creveaux, Thomas; Chèze, Laurence; Macé, Pierre; Dumas, Raphaël

    2014-01-01

    This study examined the effect of the polar moment of inertia of a tennis racket on upper limb loading in the serve. Eight amateur competition tennis players performed two sets of 10 serves using two rackets identical in mass, position of center of mass and moments of inertia other than the polar moment of inertia (0.00152 vs 0.00197 kg.m2). An eight-camera motion analysis system collected the 3D trajectories of 16 markers, located on the thorax, upper limbs and racket, from which shoulder, elbow and wrist net joint moments and powers were computed using inverse dynamics. During the cocking phase, increased racket polar moment of inertia was associated with significant increases in the peak shoulder extension and abduction moments, as well the peak elbow extension, valgus and supination moments. During the forward swing phase, peak wrist extension and radial deviation moments significantly increased with polar moment of inertia. During the follow-through phase, the peak shoulder adduction, elbow pronation and wrist external rotation moments displayed a significant inverse relationship with polar moment of inertia. During the forward swing, the magnitudes of negative joint power at the elbow and wrist were significantly larger when players served using the racket with a higher polar moment of inertia. Although a larger polar of inertia allows players to better tolerate off-center impacts, it also appears to place additional loads on the upper extremity when serving and may therefore increase injury risk in tennis players.

  20. The Sequence of Hip and Selected Upper-Extremity Joint Movements During the Golf Drive.

    ERIC Educational Resources Information Center

    Hunter, Charles L.

    This study analyzed wrist, elbow, and hip actions of golfers who were accurately driving a golf ball a maximum distance. Electrogoniometry and cinematography were used to measure wrist, forearm, elbow, and hip actions during the downswing of 10 low-handicap golfers who were attempting to drive a minimum of 225 yards within a 50-yard corridor.…

  1. On hydrodynamics of drag and lift of the human arm.

    PubMed

    Gardano, Paola; Dabnichki, Peter

    2006-01-01

    The work presents results on drag and lift measurement conducted in a low speed wind tunnel on a replica of the entire human arm. The selected model positions were identical to those during purely rotational front crawl stroke in quasi-static conditions. A computational fluid dynamics model using Fluent showed close correspondence with the experimental results and confirmed the suitability of low speed wind tunnel for the drag and lift measurement in quasi-static conditions. The obtained profiles of the hydrodynamic forces were similar to the dynamic data presented in an earlier study suggesting that shape drag is a major contributing factor in propulsive force generation. The aim of this study was to underline the importance of the entire arm analysis, the elbow angle and a newly defined angle of attack representing the angle of shoulder rotation. It was found that both the maximum value of the drag force at 160 degrees elbow flexion angle and the momentum generated by it exceed the respective magnitudes for the fully extended arm. The latter is underlined by a prolonged plateau of near maximum drag that was obtained at shoulder angle range of 50-140 degrees suggesting that optimal arm configuration in terms of propulsive force generation requires elbow flexion. Furthermore it was found that drag trend is not consistent with the widely assumed and used sinus wave profile. A gap in the existing experimental research was filled as for the first time the entire arm lift and drag was measured across the entire stroke range.

  2. Effects of free-range and confined housing on joint health in a herd of fattening pigs.

    PubMed

    Etterlin, Pernille Engelsen; Ytrehus, Bjørnar; Lundeheim, Nils; Heldmer, Eva; Österberg, Julia; Ekman, Stina

    2014-09-11

    Free-range housing, in which pigs have access to both indoor and outdoor areas, is mandatory in organic pig production in Europe, but little is known about the effects of this housing on joint health in pigs. A high level of joint condemnations at slaughter has been reported in organic free-range pigs in Sweden, compared with pigs raised in conventional confined housing. We hypothesised that biomechanical forces imposed on the joints of pigs that range freely promote the development of osteochondrosis and lead to joint condemnation. We compared the prevalence of osteochondrosis and other joint lesions (e.g. arthritis, traumatic) in the elbow and hock joints of 91 crossbred Hampshire (Yorkshire × Landrace) fattening pigs that were housed in a free-range indoor/outdoor system with that in 45 pigs housed in confined indoor pens. A larger proportion of free-range than confined pigs had osteochondrosis in the elbow joints (69 vs. 50%, p < 0.05), and a higher proportion of these joints in free-range pigs showed moderate or severe lesions (33 vs. 16%, p < 0.05). The free-range pigs also showed a higher prevalence of osteochondrosis in the hock joints (83 vs. 62%, p < 0.05) and a larger proportion of these joints had moderate or severe lesions (69 vs. 33%, p < 0.001). At slaughter, 4.2% of the free-range pigs had condemned joints, all of which showed severe osteochondrosis, while no joints of confined pigs were condemned. In this experiment the prevalence of osteochondrosis in the elbow and the hock was higher, and lesions were more severe, in free-range than in confined pigs, suggesting that free-range housing increases the risk of acquiring osteochondrosis. Increased biomechanical stress to vulnerable joint structures may be the mechanism behind this effect, however more studies are needed to verify these results. This study suggests that modification of housing, and breeding for joints that are more adapted to free-range movement may be needed in free-range pig production. Severe osteochondrosis is a cause of joint condemnation, but the condemnation rate at slaughter underestimates the actual frequency of joint lesions and hence is a poor assessment of joint health.

  3. Treatment of partial ulnar collateral ligament tears in the elbow with platelet-rich plasma.

    PubMed

    Podesta, Luga; Crow, Scott A; Volkmer, Dustin; Bert, Timothy; Yocum, Lewis A

    2013-07-01

    Studies have demonstrated the potential of platelet-rich plasma (PRP) to heal damaged tissue. To date, there are no published reports of clinical outcomes of partial ulnar collateral ligament (UCL) tears of the elbow treated with PRP. Platelet-rich plasma will promote the healing of partial UCL tears and allow a return to play. Case series; Level of evidence, 4. Thirty-four athletes with a partial-thickness UCL tear confirmed on magnetic resonance imaging were prospectively followed. All patients had failed at least 2 months of nonoperative treatment and an attempt to return to play. Baseline questionnaires, including the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow (KJOC) and Disabilities of the Arm, Shoulder and Hand (DASH) measures, were completed by each patient before injection. Baseline ultrasound measurement of the humeral-ulnar joint space was assessed with 10 lb of valgus stress on the elbow. Each patient received a single type 1A PRP injection at the UCL under ultrasound guidance. The same treating physician at a single institution performed all injections with the same PRP preparation used. Patients completed a course of guided physical therapy and were allowed to return to play based on their symptoms and physical examination findings. Outcome scores, including KJOC and DASH scores, were collected after return to play and were compared with baseline scores. Ultrasound measurements were collected at final follow-up and compared with preinjection values. At an average follow-up of 70 weeks (range, 11-117 weeks), 30 of 34 athletes (88%) had returned to the same level of play without any complaints. The average time to return to play was 12 weeks (range, 10-15 weeks). The average KJOC score improved from 46 to 93 (P < .0001). The average DASH score improved from 21 to 1 (P < .0001). The sports module of the DASH questionnaire improved from 69 to 3 (P < .0001). Medial elbow joint space opening with valgus stress decreased from 28 to 20 mm at final follow-up (P < .0001). The difference in medial elbow joint space opening (stressed vs nonstressed) decreased from 7 to 2.5 mm at final follow-up (P < .0001). One player had persistent UCL insufficiency and underwent ligament reconstruction at 31 weeks after injection. The results of this study indicate that PRP is an effective option to successfully treat partial UCL tears of the elbow in athletes.

  4. The effect of implant design of linked total elbow arthroplasty on stability and stress: a finite element analysis.

    PubMed

    Willing, Ryan; King, Graham J W; Johnson, James A

    2014-01-01

    Several linked total elbow arthroplasty designs exist, which function similar to a loose hinge joint. Constraint behaviour is an important design consideration, as it affects joint stability, or how much secondary [e.g. varus-valgus (VV)] motion is permitted. Implant durability is also a concern, as bearing failures have been reported. This finite element analysis investigates the constraint characteristics and ultra high molecular weight polyethylene bearing stresses of three linked elbow design concepts [cylindrical (CY), hourglass (HG) and concave cylinder (CC)]. The bearing of the CY design was subjected to elevated Von Mises stresses (2.1-5.4 times higher than the HG and CC designs) due to edge loading. The HG design maintained low stresses, but was unable to provide consistent VV stability. The CC design also maintained low stresses while providing consistent VV stability. These results suggest that CC designs may provide better stability characteristics and durability in vivo, compared to the other two designs.

  5. Distal Tibia Allograft Glenoid Reconstruction in Recurrent Anterior Shoulder Instability: Clinical and Radiographic Outcomes.

    PubMed

    Provencher, Matthew T; Frank, Rachel M; Golijanin, Petar; Gross, Daniel; Cole, Brian J; Verma, Nikhil N; Romeo, Anthony A

    2017-05-01

    To assess the clinical and radiographic outcomes of patients with recurrent anterior shoulder instability treated with fresh distal tibia allograft (DTA) glenoid reconstruction. Consecutive patients with a minimum 15% anterior glenoid bone loss associated with recurrent anterior instability who underwent stabilization with DTA glenoid reconstruction were retrospectively reviewed. Patients were evaluated with the American Shoulder and Elbow Society score, Western Ontario shoulder instability index, and single numerical assessment evaluation score at a minimum 2 years after surgery. All patients also underwent postoperative imaging evaluation with computed tomography where graft incorporation and allograft angle were measured. Statistical analysis was performed with paired t-tests, with P < .05 considered significant. A total of 27 patients (100% male) with an average age of 31 ± 5 years and an average follow-up of 45 months (range, 30-66) were included. There were significant improvements in preoperative to postoperative American Shoulder and Elbow Society score (63-91, P < .01), Western Ontario shoulder instability index (46% to 11% of normal, P < .01), and single numerical assessment evaluation score (50-90.5, P < .01) outcomes. Analysis of computed tomography data at an average 1.4 years postoperatively (available for 25 patients) showed an allograft healing rate of 89% (range, 80% to 100%), average allograft angle of 14.9° (range, 6.6° to 29.3°), and average allograft lysis of 3% (range, 0% to 25%). Grafts with lesser allograft angles (<15°) were better opposed to the anterior glenoid, showing superior healing and graft incorporation. There were no cases of recurrent instability. At an average follow-up of 45 months, fresh DTA reconstruction for recurrent anterior shoulder instability results in a clinically stable joint with excellent clinical outcomes and minimal graft resorption. Optimal allograft placement resulted in superior bony incorporation with the native glenoid. Level IV, therapeutic case series. Copyright © 2016 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  6. Complete 3D kinematics of upper extremity functional tasks.

    PubMed

    van Andel, Carolien J; Wolterbeek, Nienke; Doorenbosch, Caroline A M; Veeger, DirkJan H E J; Harlaar, Jaap

    2008-01-01

    Upper extremity (UX) movement analysis by means of 3D kinematics has the potential to become an important clinical evaluation method. However, no standardized protocol for clinical application has yet been developed, that includes the whole upper limb. Standardization problems include the lack of a single representative function, the wide range of motion of joints and the complexity of the anatomical structures. A useful protocol would focus on the functional status of the arm and particularly the orientation of the hand. The aim of this work was to develop a standardized measurement method for unconstrained movement analysis of the UX that includes hand orientation, for a set of functional tasks for the UX and obtain normative values. Ten healthy subjects performed four representative activities of daily living (ADL). In addition, six standard active range of motion (ROM) tasks were executed. Joint angles of the wrist, elbow, shoulder and scapula were analyzed throughout each ADL task and minimum/maximum angles were determined from the ROM tasks. Characteristic trajectories were found for the ADL tasks, standard deviations were generally small and ROM results were consistent with the literature. The results of this study could form the normative basis for the development of a 'UX analysis report' equivalent to the 'gait analysis report' and would allow for future comparisons with pediatric and/or pathologic movement patterns.

  7. Medical diagnosis of cubital tunnel syndrome ameliorated with thrust manipulation of the elbow and carpals

    PubMed Central

    Kearns, Gary; Wang, Sharon

    2012-01-01

    This case report describes the effectiveness of thrust manipulation to the elbow and carpals in the management of a patient referred with a medical diagnosis of cubital tunnel syndrome (CuTS). The patient was a 45-year-old woman with a 6-week history of right medial elbow pain, ulnar wrist pain, and intermittent paresthesia in the ulnar nerve distribution. Upon initial assessment, she presented with a positive elbow flexion test and upper limb neurodynamic test with ulnar nerve bias. A biomechanical assessment of the elbow and carpals revealed a loss of lateral glide of the humerus on the ulna and a loss of palmar glide of the triquetral on the hamate. After the patient received two thrust manipulations of the elbow and one thrust manipulation of the carpals over the course of four sessions, her pain and paresthesia were resolved. This case demonstrates that the use of thrust manipulation to the elbow and carpals may be an effective approach in the management of insidious onset CuTS. This patient was successfully treated with thrust manipulation when joint dysfunction of the elbow and wrist were appropriately identified. This case report may shed light on the examination and management of insidious onset CuTS. PMID:23633888

  8. Biomechanical comparison of graft fixation at 30° and 90° of elbow flexion for ulnar collateral ligament reconstruction by the docking technique.

    PubMed

    Cohen, Steven B; Woods, Daniel P; Siegler, Sorin; Dodson, Christopher C; Namani, Ramya; Ciccotti, Michael G

    2015-02-01

    Ulnar collateral ligament (UCL) injuries have been successfully treated by the docking reconstruction. Although fixation of the graft has been suggested at 30° of elbow flexion, no quantitative biomechanical data exist to provide guidelines for the optimal elbow flexion angle for graft fixation. Testing was conducted on 10 matched pairs of cadaver elbows with use of a loading system and optoelectric tracking device. After biomechanical data on the native UCL were obtained, reconstruction by the docking technique was performed with use of palmaris longus autograft with one elbow fixated at 30° and the contralateral elbow at 90° of elbow flexion. Biomechanical testing was undertaken on these specimens. The load to failure of the native UCL (mean, 20.1 N-m) was significantly higher (P = .004) than that of the reconstructed UCL (mean, 4.6 N-m). There was no statistically significant difference in load to failure of the UCL reconstructions fixated at 30° of elbow flexion (average, 4.86 N-m) compared with those at 90° (average, 4.35 N-m). Elbows reconstructed at 30° and 90° of elbow flexion produced similar kinematic coupling and valgus laxity characteristics compared with each other and with the intact UCL. Although not statistically significant, the reconstructions fixated at 30° more closely resembled the biomechanical characteristics of the intact elbow than did reconstructions fixated at 90°. No statistically significant difference was found in comparing the docking technique of UCL reconstruction with graft fixation at 30° vs. 90° of elbow flexion. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  9. Impingement of Droplets in 60 Deg Elbows with Potential Flow

    NASA Technical Reports Server (NTRS)

    Hacker, Paul T.; Saper, Paul G.; Kadow, Charles F.

    1956-01-01

    Trajectories were determined for water droplets or other aerosol particles in air flowing through 600 elbows especially designed for two-dimensional potential motion. The elbows were established by selecting as walls of each elbow two streamlines of a flow field produced by a complex potential function that establishes a two-dimensional flow around. a 600 bend. An unlimited number of elbows with slightly different shapes can be established by selecting different pairs of streamlines as walls. Some of these have a pocket on the outside wall. The elbows produced by the complex potential function are suitable for use in aircraft air-inlet ducts and have the following characteristics: (1) The resultant velocity at any point inside the elbow is always greater than zero but never exceeds the velocity at the entrance. (2) The air flow field at the entrance and exit is almost uniform and rectilinear. (3) The elbows are symmetrical with respect to the bisector of the angle of bend. These elbows should have lower pressure losses than bends of constant cross-sectional area. The droplet impingement data derived from the trajectories are presented along with equations so that collection efficiency, area, rate, and distribution of droplet impingement can be determined for any elbow defined by any pair of streamlines within a portion of the flow field established by the complex potential function. Coordinates for some typical streamlines of the flow field and velocity components for several points along these streamlines are presented in tabular form. A comparison of the 600 elbow with previous calculations for a comparable 90 elbow indicated that the impingement characteristics of the two elbows were very similar.

  10. Effects of the Racket Polar Moment of Inertia on Dominant Upper Limb Joint Moments during Tennis Serve

    PubMed Central

    Rogowski, Isabelle; Creveaux, Thomas; Chèze, Laurence; Macé, Pierre; Dumas, Raphaël

    2014-01-01

    This study examined the effect of the polar moment of inertia of a tennis racket on upper limb loading in the serve. Eight amateur competition tennis players performed two sets of 10 serves using two rackets identical in mass, position of center of mass and moments of inertia other than the polar moment of inertia (0.00152 vs 0.00197 kg.m2). An eight-camera motion analysis system collected the 3D trajectories of 16 markers, located on the thorax, upper limbs and racket, from which shoulder, elbow and wrist net joint moments and powers were computed using inverse dynamics. During the cocking phase, increased racket polar moment of inertia was associated with significant increases in the peak shoulder extension and abduction moments, as well the peak elbow extension, valgus and supination moments. During the forward swing phase, peak wrist extension and radial deviation moments significantly increased with polar moment of inertia. During the follow-through phase, the peak shoulder adduction, elbow pronation and wrist external rotation moments displayed a significant inverse relationship with polar moment of inertia. During the forward swing, the magnitudes of negative joint power at the elbow and wrist were significantly larger when players served using the racket with a higher polar moment of inertia. Although a larger polar of inertia allows players to better tolerate off-center impacts, it also appears to place additional loads on the upper extremity when serving and may therefore increase injury risk in tennis players. PMID:25117871

  11. Early rheumatoid disease. II. Patterns of joint involvement.

    PubMed Central

    Fleming, A; Benn, R T; Corbett, M; Wood, P H

    1976-01-01

    Data from the first research clinic visit (Fleming and others, 1976) have been subjected to factor analysis to identify early patterns of joint involvement. Nine patterns emerged. Two patterns, if present early, were found to have prognostic significance. An eventually more severe disease was associated with a pattern of large joint involvement (shoulder, elbow, wrist, knee) and a pattern based on metatarsophalangeal joints I and III. PMID:970995

  12. Osteochondrosis dissecans of the elbow.

    PubMed

    Van Sonhoven, F; Geusens, E; Nijs, S

    2009-01-01

    This case shows a typical presentation of an osteochondrosis dissecans lesion on the capitellum, with associated intra-articular loose bodie(s), diagnosed on plain film. Osteochondrosis dissecans (OCD) is a rather common entity. Mostly the knee joint is involved. Only 5% of OCD lesions occur in the elbow joint. Possible causes of osteochondrosis dissecans include (repetitive) trauma (e.g. in throwing sports or gymnastics), ischemia, ossification defects, and genetic factors. Conventional radiography mostly has a low sensitivity to detect OCD lesions, and is often normal in early stages. CT is more sensitive to detect intra-articular loose bodies. MRI detects very early stages of OCD and radiographically occult lesions that may not be evident on CT.

  13. Subcutaneous pedicle propeller flap: An old technique revisited and modified!

    PubMed Central

    Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash

    2016-01-01

    Background: Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. Methodology: This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Results: Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. Conclusion: The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap. PMID:27833285

  14. Subcutaneous pedicle propeller flap: An old technique revisited and modified!

    PubMed

    Karki, Durga; Mehta, Nikhil; Narayan, Ravi Prakash

    2016-01-01

    Post-burn axillary and elbow scar contracture is a challenging problem to the reconstructive surgeon owing to the wide range of abduction and extension that should be achieved, respectively, while treating either of the joint. The aim of this paper is to highlight the use of subcutaneous pedicle propeller flap for the management of post-burn axillary and elbow contractures. This is a prospective case study of axillary and elbow contractures managed at a tertiary care hospital using propeller flap based on subcutaneous pedicle from 2009 to 2014. Surgical treatment comprised of subcutaneous-based pedicle propeller flap from the normal tissue within the contracture based on central axis pedicle. The flap was rotated axially to break the contracture. The technique further encompassed a modification, a Zig-Zag incision of the flap, which was seen to prevent hypertrophy along the incision line. There was a mean period of 12 months of follow-up. Thirty-eight patients consisting of 22 males and 16 females were included in this study among which 23 patients had Type II axillary contractures and 15 had moderate flexion contractures at elbow joint. The post-operative abduction achieved at shoulder joint had a mean of 168° whereas extension achieved at elbow had a mean of 175°. The functional and aesthetic results were satisfactory. The choice of surgical procedure for reconstruction of post-burn upper extremity contractures should be made according to the pattern of scar contracture and the state of surrounding skin. The choice of subcutaneous pedicle propeller flap should be emphasised because of the superior functional results of flap as well as ease to learn it. Moreover, the modification of propeller flap described achieves better results in terms of scar healing. There is an inter-positioning of healthy skin in between the graft, so it prevents scar band formation all around the flap.

  15. Computing muscle, ligament, and osseous contributions to the elbow varus moment during baseball pitching

    PubMed Central

    Buffi, James H.; Werner, Katie; Kepple, Tom; Murray, Wendy M.

    2014-01-01

    Baseball pitching imposes a dangerous valgus load on the elbow that puts the joint at severe risk for injury. The goal of this study was to develop a musculoskeletal modeling approach to enable evaluation of muscle-tendon contributions to mitigating elbow injury risk in pitching. We implemented a forward dynamic simulation framework that used a scaled biomechanical model to reproduce a pitching motion recorded from a high school pitcher. The medial elbow muscles generated substantial, protective, varus elbow moments in our simulations. For our subject, the triceps generated large varus moments at the time of peak valgus loading; varus moments generated by the flexor digitorum superficialis were larger, but occurred later in the motion. Increasing muscle-tendon force output, either by augmenting parameters associated with strength and power or by increasing activation levels, decreased the load on the ulnar collateral ligament. Published methods have not previously quantified the biomechanics of elbow muscles during pitching. This simulation study represents a critical advancement in the study of baseball pitching and highlights the utility of simulation techniques in the study of this difficult problem. PMID:25281409

  16. Pennation angle dependency in skeletal muscle tissue doppler strain in dynamic contractions.

    PubMed

    Lindberg, Frida; Öhberg, Fredrik; Granåsen, Gabriel; Brodin, Lars-Åke; Grönlund, Christer

    2011-07-01

    Tissue velocity imaging (TVI) is a Doppler based ultrasound technique that can be used to study regional deformation in skeletal muscle tissue. The aim of this study was to develop a biomechanical model to describe the TVI strain's dependency on the pennation angle. We demonstrate its impact as the subsequent strain measurement error using dynamic elbow contractions from the medial and the lateral part of biceps brachii at two different loadings; 5% and 25% of maximum voluntary contraction (MVC). The estimated pennation angles were on average about 4° in extended position and increased to a maximal of 13° in flexed elbow position. The corresponding relative angular error spread from around 7% up to around 40%. To accurately apply TVI on skeletal muscles, the error due to angle changes should be compensated for. As a suggestion, this could be done according to the presented model. Copyright © 2011 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  17. Comparison of joint space and end point space robotic training modalities for rehabilitation of interjoint coordination in individuals with moderate to severe impairment from chronic stroke.

    PubMed

    Brokaw, Elizabeth B; Holley, Rahsaan J; Lum, Peter S

    2013-09-01

    We have developed a novel robotic modality called Time Independent Functional Training (TIFT) that provides focused retraining of interjoint coordination after stroke. TIFT was implemented on the ARMin III exoskeleton and provides joint space walls that resist movement patterns that are inconsistent with the targeted interjoint coordination pattern. In a single test session, ten moderate to severely impaired individuals with chronic stroke practiced synchronous shoulder abduction and elbow extension in TIFT and also in a comparison mode commonly used in robotic therapy called end point tunnel training (EPTT). In EPTT, error is limited by forces applied to the hand that are normal to the targeted end point trajectory. The completion percentage of the movements was comparable between modes, but the coordination patterns used by subjects differed between modes. In TIFT, subjects performed the targeted pattern of synchronous shoulder abduction and elbow extension, while in EPTT, movements were completed with compensatory strategies that incorporated the flexor synergy (shoulder abduction with elbow flexion) or the extensor synergy (shoulder adduction with elbow extension). There were immediate effects on free movements, with TIFT resulting in larger improvements in interjoint coordination than EPTT. TIFT's ability to elicit normal coordination patterns merits further investigation into the effects of longer duration training.

  18. Correlation of Shoulder and Elbow Kinetics With Ball Velocity in Collegiate Baseball Pitchers.

    PubMed

    Post, Eric G; Laudner, Kevin G; McLoda, Todd A; Wong, Regan; Meister, Keith

    2015-06-01

    Throwing a baseball is a dynamic and violent act that places large magnitudes of stress on the shoulder and elbow. Specific injuries at the elbow and glenohumeral joints have been linked to several kinetic variables throughout the throwing motion. However, very little research has directly examined the relationship between these kinetic variables and ball velocity. To examine the correlation of peak ball velocity with elbow-valgus torque, shoulder external-rotation torque, and shoulder-distraction force in a group of collegiate baseball pitchers. Cross-sectional study. Motion-analysis laboratory. Sixty-seven asymptomatic National Collegiate Athletic Association Division I baseball pitchers (age = 19.5 ± 1.2 years, height = 186.2 ± 5.7 cm, mass = 86.7 ± 7.0 kg; 48 right handed, 19 left handed). We measured peak ball velocity using a radar gun and shoulder and elbow kinetics of the throwing arm using 8 electronically synchronized, high-speed digital cameras. We placed 26 reflective markers on anatomical landmarks of each participant to track 3-dimensional coordinate data. The average data from the 3 highest-velocity fastballs thrown for strikes were used for data analysis. We calculated a Pearson correlation coefficient to determine the associations between ball velocity and peak elbow-valgus torque, shoulder-distraction force, and shoulder external-rotation torque (P < .05). A weak positive correlation was found between ball velocity and shoulder-distraction force (r = 0.257; 95% confidence interval [CI] = 0.02, 0.47; r(2) = 0.066; P = .018). However, no significant correlations were noted between ball velocity and elbow-valgus torque (r = 0.199; 95% CI = -0.043, 0.419; r(2) = 0.040; P = .053) or shoulder external-rotation torque (r = 0.097; 95% CI = -0.147, 0.329; r(2) = 0.009; P = .217). Although a weak positive correlation was present between ball velocity and shoulder-distraction force, no significant association was seen between ball velocity and elbow-valgus torque or shoulder external-rotation torque. Therefore, other factors, such as improper pitching mechanics, may contribute more to increases in joint kinetics than peak ball velocity.

  19. Correlation of Shoulder and Elbow Kinetics With Ball Velocity in Collegiate Baseball Pitchers

    PubMed Central

    Post, Eric G.; Laudner, Kevin G.; McLoda, Todd A.; Wong, Regan; Meister, Keith

    2015-01-01

    Context Throwing a baseball is a dynamic and violent act that places large magnitudes of stress on the shoulder and elbow. Specific injuries at the elbow and glenohumeral joints have been linked to several kinetic variables throughout the throwing motion. However, very little research has directly examined the relationship between these kinetic variables and ball velocity. Objective To examine the correlation of peak ball velocity with elbow-valgus torque, shoulder external-rotation torque, and shoulder-distraction force in a group of collegiate baseball pitchers. Design Cross-sectional study. Setting Motion-analysis laboratory. Patients or Other Participants Sixty-seven asymptomatic National Collegiate Athletic Association Division I baseball pitchers (age = 19.5 ± 1.2 years, height = 186.2 ± 5.7 cm, mass = 86.7 ± 7.0 kg; 48 right handed, 19 left handed). Main Outcome Measure(s) We measured peak ball velocity using a radar gun and shoulder and elbow kinetics of the throwing arm using 8 electronically synchronized, high-speed digital cameras. We placed 26 reflective markers on anatomical landmarks of each participant to track 3-dimensional coordinate data. The average data from the 3 highest-velocity fastballs thrown for strikes were used for data analysis. We calculated a Pearson correlation coefficient to determine the associations between ball velocity and peak elbow-valgus torque, shoulder-distraction force, and shoulder external-rotation torque (P < .05). Results A weak positive correlation was found between ball velocity and shoulder-distraction force (r = 0.257; 95% confidence interval [CI] = 0.02, 0.47; r2 = 0.066; P = .018). However, no significant correlations were noted between ball velocity and elbow-valgus torque (r = 0.199; 95% CI = −0.043, 0.419; r2 = 0.040; P = .053) or shoulder external-rotation torque (r = 0.097; 95% CI = −0.147, 0.329; r2 = 0.009; P = .217). Conclusions Although a weak positive correlation was present between ball velocity and shoulder-distraction force, no significant association was seen between ball velocity and elbow-valgus torque or shoulder external-rotation torque. Therefore, other factors, such as improper pitching mechanics, may contribute more to increases in joint kinetics than peak ball velocity. PMID:25756790

  20. Voluntary control of arm movement in athetotic patients

    PubMed Central

    Neilson, Peter D.

    1974-01-01

    Visual tracking tests have been employed to provide a quantitative description of voluntary control of arm movement in a group of patients suffering from athetoid cerebral palsy. Voluntary control was impaired in all patients in a characteristic manner. Maximum velocity and acceleration of arm movement were reduced to about 30-50% of their values in normal subjects and the time lag of the response to a visual stimulus was two or three times greater than in normals. Tracking transmission characteristics indicated a degree of underdamping which was not presnet in normal or spastic patients. This underdamping could be responsible for a low frequency (0·3-0·6 Hz) transient oscillation in elbow-angle movements associated with sudden voluntary movement. The maximum frequency at which patients could produce a coherent tracking response was only 50% of that in normal subjects and the relationship between the electromyogram and muscle contraction indicated that the mechanical load on the biceps muscle was abnormal, possibly due to increased stiffness of joint movement caused by involuntary activity in agonist and antagonist muscles acting across the joint. Images PMID:4362243

  1. Close-wedge osteotomy for bony locking stiffness of the elbow in Gorham disease patients: a case report.

    PubMed

    Wang, Hsien-Chung; Lin, Gau-Tyan

    2004-05-01

    Gorham disease is a so-called massive idiopathic osteolysis or vanishing bone disorder. Massive osteolysis remains an enigmatic condition that involves various skeletal locations and is caused by endothelial proliferation. The diagnosis is difficult and is established via the association of clinical, radiologic and histologic pictures. Treatment modalities yield variable results. We report a case of vanishing bone in the elbow joint and carpal bones following trauma. This 13-year-old boy complained of severe restricted motion and deformity of the right elbow. We managed the problem using arthroplasty with close-wedge osteotomy on the lateral condyle of the humerus.

  2. Biomechanics of youth windmill softball pitching.

    PubMed

    Werner, Sherry L; Guido, John A; McNeice, Ryan P; Richardson, Jasper L; Delude, Neil A; Stewart, Gregory W

    2005-04-01

    Limited research attention has been paid to the potentially harmful windmill softball pitch. No information is available regarding lower extremity kinetics in softball pitching. The stresses on the throwing arm of youth windmill pitchers are clinically significant and similar to those found for college softball pitchers. Descriptive laboratory study. Three-dimensional, high-speed (240-Hz) video and stride foot force plate (1200 Hz) data were collected on fastballs from 53 youth softball pitchers. Kinematic parameters related to pitching mechanics and resultant kinetics on the throwing-arm elbow and shoulder joints were calculated. Kinetic parameters were compared to those reported for baseball pitchers. Elbow and shoulder joint loads were similar to those found for baseball pitchers and college softball pitchers. Shoulder distraction stress averaged 94% body weight for the youth pitchers. Stride foot ground reaction force patterns were not similar to those reported for baseball pitchers. Vertical and braking force components under the stride foot were in excess of body weight. Excessive distraction stress and joint torques at the throwing-arm elbow and shoulder are similar to those found in baseball pitchers, which suggests that windmill softball pitchers are at risk for overuse injuries. Normative information regarding upper and lower extremity kinematics and kinetics for 12- to 19-year-old softball pitchers has been established.

  3. Differences in Muscle Activation and Kinematics Between Cable-Based and Selectorized Weight Training.

    PubMed

    Signorile, Joseph F; Rendos, Nicole K; Heredia Vargas, Hector H; Alipio, Taislaine C; Regis, Rebecca C; Eltoukhy, Moataz M; Nargund, Renu S; Romero, Matthew A

    2017-02-01

    Signorile, JF, Rendos, NK, Heredia Vargas, HH, Alipio, TC, Regis, RC, Eltoukhy, MM, Nargund, RS, and Romero, MA. Differences in muscle activation and kinematics between cable-based and selectorized weight training. J Strength Cond Res 31(2): 313-322, 2017-Cable resistance training machines are showing resurgent popularity and allow greater number of degrees of freedom than typical selectorized equipment. Given that specific kinetic chains are used during distinct activities of daily living (ADL), cable machines may provide more effective interventions for some ADL, whereas others may be best addressed using selectorized equipment. This study examined differences in activity levels (root mean square of the EMG [rmsEMG]) of 6 major muscles (pectoralis major, PM; anterior deltoid, AD; biceps brachii, BB; rectus abdominis, RA; external obliques, EO; and triceps brachii, TB) and kinematics of multiple joints between a cable and standard selectorized machines during the biceps curl, the chest press, and the overhead press performed at 1.5 seconds per contractile stage. Fifteen individuals (9 men, 6 women; mean age ± SD, 24.33 ± 4.88 years) participated. Machine order was randomized. Significant differences favoring cable training were seen for PM and AD during biceps curl; BB, AD, and EO for chest press; and BB and EO during overhead press (p ≤ 0.05). Greater starting and ending angles were seen for the elbow and shoulder joints during selectorized biceps curl, whereas hip and knee starting and ending angles were greater for cable machine during chest and overhead presses (p < 0.0001). Greater range of motion (ROM) favoring the cable machine was also evident (p < 0.0001). These results indicate that utilization patterns of selected muscles, joint angles, and ROMs can be varied because of machine application even when similar exercises are used, and therefore, these machines can be used selectively in training programs requiring specific motor or biomechanical patterns.

  4. Anatomy of the collateral ligaments of the feline elbow joint: functional implications.

    PubMed

    Engelke, E; Pfarrer, C; Waibl, H

    2011-04-01

    Cats show a higher capability to supinate their forearms than dogs. This suggests a special arrangement of the collateral ligaments of the feline elbow joint. Therefore, the course of the ligaments was examined in 13 adult cats. The size of the ligaments was measured, and effects of passive joint movements were studied. Ligaments of five additional cats were examined histologically. The lateral collateral ligament (LCL) had a superficial and deep part, both originating from the humerus. The free humeral portion of the LCL was short and contained fibrous cartilage. Fibre bundles of the deep part inserted into the annular ligament, while the remaining deep fibres and the superficial part inserted with a long antebrachial portion on the radius. The medial collateral ligament (MCL) originated from the humeral epicondyle and divided into cranial and caudal parts. The caudal part inserted medioproximally on the ulna, while the cranial part attached primarily with a long thin part to the caudal aspect of the radius. During supination, the MCL loosened thus allowing medial widening of the joint space, up to 2 mm. A specific feature of the feline elbow is the long thin part of the MCL. Its course through a special furrow distal to the medial coronoid causes the tightening of the feline MCL during pronation. Apart from that, the feline collateral ligaments combine the features of both human and canine cubital anatomy. This explains the range of supination in cats, which is intermediate between humans and dogs. © 2010 Blackwell Verlag GmbH.

  5. Arthroscopic management of the painful total elbow arthroplasty.

    PubMed

    Phadnis, Joideep; Bain, Gregory I

    2016-01-01

    Failure of total elbow arthroplasty is more common than after other major joint arthroplasties and is often a result of aseptic loosening, peri-prosthetic infection, fracture and instability. Infection can be a devastating complication, yet there are no established guidelines for the pre-operative diagnosis of total elbow peri-prosthetic infection. This is because pre-operative clinical, radiographic and biochemical tests are often unreliable. Using three case examples, a standardized protocol for the clinical and arthroscopic assessment of the painful total elbow arthroplasty is described. This is used to provide a mechanical and microbiological diagnosis of the patient's pain. There have been no complications resulting from the use of this technique in the three patients described, nor in any other patient to date. The staged protocol described in the present study, utilizing arthroscopic assessment, has refined the approach to the painful total elbow arthroplasty because it directly influences the definitive surgical management of the patient. It is recommended that other surgeons follow the principles outlined in the present study when faced with this challenging problem.

  6. Evaluation of a subject-specific, torque-driven computer simulation model of one-handed tennis backhand groundstrokes.

    PubMed

    Kentel, Behzat B; King, Mark A; Mitchell, Sean R

    2011-11-01

    A torque-driven, subject-specific 3-D computer simulation model of the impact phase of one-handed tennis backhand strokes was evaluated by comparing performance and simulation results. Backhand strokes of an elite subject were recorded on an artificial tennis court. Over the 50-ms period after impact, good agreement was found with an overall RMS difference of 3.3° between matching simulation and performance in terms of joint and racket angles. Consistent with previous experimental research, the evaluation process showed that grip tightness and ball impact location are important factors that affect postimpact racket and arm kinematics. Associated with these factors, the model can be used for a better understanding of the eccentric contraction of the wrist extensors during one-handed backhand ground strokes, a hypothesized mechanism of tennis elbow.

  7. Heads, Shoulders, Elbows, Knees, and Toes: Modular Gdf5 Enhancers Control Different Joints in the Vertebrate Skeleton

    PubMed Central

    Schoor, Michael; Mortlock, Doug P.; Reddi, A. Hari; Kingsley, David M.

    2016-01-01

    Synovial joints are crucial for support and locomotion in vertebrates, and are the frequent site of serious skeletal defects and degenerative diseases in humans. Growth and differentiation factor 5 (Gdf5) is one of the earliest markers of joint formation, is required for normal joint development in both mice and humans, and has been genetically linked to risk of common osteoarthritis in Eurasian populations. Here, we systematically survey the mouse Gdf5 gene for regulatory elements controlling expression in synovial joints. We identify separate regions of the locus that control expression in axial tissues, in proximal versus distal joints in the limbs, and in remarkably specific sub-sets of composite joints like the elbow. Predicted transcription factor binding sites within Gdf5 regulatory enhancers are required for expression in particular joints. The multiple enhancers that control Gdf5 expression in different joints are distributed over a hundred kilobases of DNA, including regions both upstream and downstream of Gdf5 coding exons. Functional rescue tests in mice confirm that the large flanking regions are required to restore normal joint formation and patterning. Orthologs of these enhancers are located throughout the large genomic region previously associated with common osteoarthritis risk in humans. The large array of modular enhancers for Gdf5 provide a new foundation for studying the spatial specificity of joint patterning in vertebrates, as well as new candidates for regulatory regions that may also influence osteoarthritis risk in human populations. PMID:27902701

  8. Prevalence of joint-related pain in the extremities and spine in five groups of top athletes.

    PubMed

    Jonasson, Pall; Halldin, Klas; Karlsson, Jon; Thoreson, Olof; Hvannberg, Jonas; Swärd, Leif; Baranto, Adad

    2011-09-01

    Joint-related pain conditions from the spine and extremities are common among top athletes. The frequency of back pain has, however, been studied in more detail, and the frequency of low-back pain in top athletes in different high-load sports has been reported to be as high as 85%. Sport-related pain from different joints in the extremities is, however, infrequently reported on in the literature. Seventy-five male athletes, i.e. divers, weight-lifters, wrestlers, orienteers and ice-hockey players and 12 non-athletes (control group) were included in the study. A specific self-assessed pain-oriented questionnaire related to the cervical, thoracic and lumbar spine, as well as the various joints, i.e. shoulders, elbows, wrists, hips, knees and ankles, was filled out by the athletes and the non-athletes. The overall frequency of pain reported by the athletes during the last week/last year was as follows; cervical spine 35/55%; thoracic spine 22/33%; lumbar spine 50/68%; shoulder 10/21%; elbow 7/7%; wrist 7/8%; hip 15/23%; knee 22/44%; and ankle 11/25%. The corresponding values for non-athletes were cervical spine 9/36%; thoracic spine 17/33%; lumbar spine 36/50%; shoulder 0/9%; elbow 9/0%; wrist 0/0%; hip 9/16%; knee 10/9%; and ankle 0/0%. A higher percentage of athletes reported pain in almost all joint regions, but there were no statistically significant differences (n.s.), with the exception of the knees (P = 0.05). Over the last year, athletes reporting the highest pain frequency in the lumbar spine were ice-hockey players and, in the cervical spine, wrestlers and ice-hockey players. The highest levels of knee pain were found among wrestlers and ice-hockey players, whereas the highest levels for wrist pain were found among divers, hip pain among weight-lifters, orienteers and divers and ankle pain among orienteers. For the thoracic spine, shoulder and elbow regions, only minor differences were found. There was no statistically significant difference in prevalence of pain in the neck, spine and joints between top athletes in different sports or between athletes and non-athletes. However, pain in one spinal region was correlated to reported pain in other regions of the spine. Moreover, pain in the spine was also correlated to pain in the shoulders, hips and knees.

  9. Proprioceptive coordination of movement sequences: role of velocity and position information.

    PubMed

    Cordo, P; Carlton, L; Bevan, L; Carlton, M; Kerr, G K

    1994-05-01

    1. Recent studies have shown that the CNS uses proprioceptive information to coordinate multijoint movement sequences; proprioceptive input related to the kinematics of one joint rotation in a movement sequence can be used to trigger a subsequent joint rotation. In this paper we adopt a broad definition of "proprioception," which includes all somatosensory information related to joint posture and kinematics. This paper addresses how the CNS uses proprioceptive information related to the velocity and position of joints to coordinate multijoint movement sequences. 2. Normal human subjects sat at an experimental apparatus and performed a movement sequence with the right arm without visual feedback. The apparatus passively rotated the right elbow horizontally in the extension direction with either a constant velocity trajectory or an unpredictable velocity trajectory. The subjects' task was to open briskly the right hand when the elbow passed through a prescribed target position, similar to backhand throwing in the horizontal plane. The randomization of elbow velocities and the absence of visual information was used to discourage subjects from using any information other than proprioceptive input to perform the task. 3. Our results indicate that the CNS is able to extract the necessary kinematic information from proprioceptive input to trigger the hand opening at the correct elbow position. We estimated the minimal sensory conduction and processing delay to be 150 ms, and on the basis of this estimate, we predicted the expected performance with different degrees of reduced proprioceptive information. These predictions were compared with the subjects' actual performances, revealing that the CNS was using proprioceptive input related to joint velocity in this motor task. To determine whether position information was also being used, we examined the subjects' performances with unpredictable velocity trajectories. The results from experiments with unpredictable velocity trajectories indicate that the CNS extracts proprioceptive information related to both the velocity and the angular position of the joint to trigger the hand movement in this movement sequence. 4. To determine the generality of proprioceptive triggering in movement sequences, we estimated the minimal movement duration with which proprioceptive information can be used as well as the amount of learning required to use proprioceptive input to perform the task. The temporal limits for proprioceptive processing in this movement task were established by determining the minimal movement time during which the task could be performed.(ABSTRACT TRUNCATED AT 400 WORDS)

  10. High temperature lined conduits, elbows and tees

    DOEpatents

    De Feo, Angelo; Drewniany, Edward

    1982-01-01

    A high temperature lined conduit comprising, a liner, a flexible insulating refractory blanket around and in contact with the liner, a pipe member around the blanket and spaced therefrom, and castable rigid refractory material between the pipe member and the blanket. Anchors are connected to the inside diameter of the pipe and extend into the castable material. The liner includes male and female slip joint ends for permitting thermal expansion of the liner with respect to the castable material and the pipe member. Elbows and tees of the lined conduit comprise an elbow liner wrapped with insulating refractory blanket material around which is disposed a spaced elbow pipe member with castable refractory material between the blanket material and the elbow pipe member. A reinforcing band is connected to the elbow liner at an intermediate location thereon from which extend a plurality of hollow tubes or pins which extend into the castable material to anchor the lined elbow and permit thermal expansion. A method of fabricating the high temperature lined conduit, elbows and tees is also disclosed which utilizes a polyethylene layer over the refractory blanket after it has been compressed to maintain the refractory blanket in a compressed condition until the castable material is in place. Hot gases are then directed through the interior of the liner for evaporating the polyethylene and setting the castable material which permits the compressed blanket to come into close contact with the castable material.

  11. Elbow instability: Are we able to classify it? Review of the literature and proposal of an all-inclusive classification system.

    PubMed

    Marinelli, A; Guerra, E; Rotini, R

    2016-12-01

    In the recent years, considerable improvements have come in biomechanical knowledge about the role of elbow stabilizers. In particular, the complex interactions among the different stabilizers when injured at the same time have been better understood. Anyway, uncertainties about both nomenclature and classification still exist in the definition of the different patterns of instability. The authors examine the literature of the last 130 years about elbow instability classification, analyzing the intuitions and the value of each of them. However, because of the lack of a satisfactory classification, in 2015 a working group has been created inside SICSeG (Italian Society of Shoulder and Elbow Surgery) with the aim of defining an exhaustive classification as simple, complete and reproducible as possible. A new all-inclusive elbow instability classification is proposed. This classification considers two main parameters: timing (acute and chronic forms) and involved stabilizers (simple and complex forms), and four secondary parameters: etiology (traumatic, rheumatic, congenital…), the involved joint (radius and ulna as a single unit articulating with the humerus or the proximal radio-ulnar joint), the degree of displacement (dislocation or subluxation) and the mechanism of instability or dislocation (PLRI, PMRI, direct axial loading, pure varus or valgus stress). This classification is at the same time complete enough to include all the instability patterns and practical enough to be effectively used in the clinical practice. This classification can help in defining a shared language, can improve our understanding of the disorder, reduce misunderstanding of diagnosis and improve comparison among different case series.

  12. Exploration of Hand Grasp Patterns Elicitable Through Non-Invasive Proximal Nerve Stimulation.

    PubMed

    Shin, Henry; Watkins, Zach; Hu, Xiaogang

    2017-11-29

    Various neurological conditions, such as stroke or spinal cord injury, result in an impaired control of the hand. One method of restoring this impairment is through functional electrical stimulation (FES). However, traditional FES techniques often lead to quick fatigue and unnatural ballistic movements. In this study, we sought to explore the capabilities of a non-invasive proximal nerve stimulation technique in eliciting various hand grasp patterns. The ulnar and median nerves proximal to the elbow joint were activated transcutanously using a programmable stimulator, and the resultant finger flexion joint angles were recorded using a motion capture system. The individual finger motions averaged across the three joints were analyzed using a cluster analysis, in order to classify the different hand grasp patterns. With low current intensity (<5 mA and 100 µs pulse width) stimulation, our results show that all of our subjects demonstrated a variety of consistent hand grasp patterns including single finger movement and coordinated multi-finger movements. This study provides initial evidence on the feasibility of a proximal nerve stimulation technique in controlling a variety of finger movements and grasp patterns. Our approach could also be developed into a rehabilitative/assistive tool that can result in flexible movements of the fingers.

  13. Impact of hospitalization in an intensive care unit on range of motion of critically ill patients: a pilot study

    PubMed Central

    Nepomuceno, Balbino Rivail Ventura; Martinez, Bruno Prata; Gomes Neto, Mansueto

    2014-01-01

    Objective To evaluate the joint range of motion of critically ill patients during hospitalization in the intensive care unit. Methods This work was a prospective longitudinal study conducted in a critical care unit of a public hospital in the city of Salvador (BA) from September to November 2010. The main variable evaluated was the passive joint range of motion. A goniometer was used to measure the elbows, knees and ankles at the time of admission and at discharge. All patients admitted in the period were included other than patients with length of stay <72 hours and patients with reduced joint range of motion on admission. Results The sample consisted of 22 subjects with a mean age of 53.5±17.6 years, duration of stay in the intensive care unit of 13.0±6.0 days and time on mechanical ventilation of 12.0±6.3 days. The APACHE II score was 28.5±7.3, and the majority of patients had functional independence at admission with a prior Barthel index of 88.8±19. The losses of joint range of motion were 11.1±2.1°, 11.0±2.2°, 8.4±1.7°, 9.2±1.6°, 5.8±0.9° and 5.1±1.0°, for the right and left elbows, knees and ankles, respectively (p<0.001). Conclusion There was a tendency towards decreased range of motion of large joints such as the ankle, knee and elbow during hospitalization in the intensive care unit. PMID:24770691

  14. A Neuromuscular Electrical Stimulation (NMES) and robot hybrid system for multi-joint coordinated upper limb rehabilitation after stroke.

    PubMed

    Rong, Wei; Li, Waiming; Pang, Mankit; Hu, Junyan; Wei, Xijun; Yang, Bibo; Wai, Honwah; Zheng, Xiaoxiang; Hu, Xiaoling

    2017-04-26

    It is a challenge to reduce the muscular discoordination in the paretic upper limb after stroke in the traditional rehabilitation programs. In this study, a neuromuscular electrical stimulation (NMES) and robot hybrid system was developed for multi-joint coordinated upper limb physical training. The system could assist the elbow, wrist and fingers to conduct arm reaching out, hand opening/grasping and arm withdrawing by tracking an indicative moving cursor on the screen of a computer, with the support from the joint motors and electrical stimulations on target muscles, under the voluntary intention control by electromyography (EMG). Subjects with chronic stroke (n = 11) were recruited for the investigation on the assistive capability of the NMES-robot and the evaluation of the rehabilitation effectiveness through a 20-session device assisted upper limb training. In the evaluation, the movement accuracy measured by the root mean squared error (RMSE) during the tracking was significantly improved with the support from both the robot and NMES, in comparison with those without the assistance from the system (P < 0.05). The intra-joint and inter-joint muscular co-contractions measured by EMG were significantly released when the NMES was applied to the agonist muscles in the different phases of the limb motion (P < 0.05). After the physical training, significant improvements (P < 0.05) were captured by the clinical scores, i.e., Modified Ashworth Score (MAS, the elbow and the wrist), Fugl-Meyer Assessment (FMA), Action Research Arm Test (ARAT), and Wolf Motor Function Test (WMFT). The EMG-driven NMES-robotic system could improve the muscular coordination at the elbow, wrist and fingers. ClinicalTrials.gov. NCT02117089 ; date of registration: April 10, 2014.

  15. The ulnar collateral ligament of the human elbow joint. Anatomy, function and biomechanics.

    PubMed Central

    Fuss, F K

    1991-01-01

    The posterior portion of the ulnar collateral ligament, which arises from the posterior surface of the medial epicondyle, is taut in maximal flexion. The anterior portion, which takes its origin from the anterior and inferior surfaces of the epicondyle, contains three functional fibre bundles. One of these is taut in maximal extension, another in intermediate positions between middle position and full flexion while the third bundle is always taut and serves as a guiding bundle. Movements of the elbow joint are checked by the ligaments well before the bony processes forming the jaws of the trochlear notch lock into the corresponding fossae on the humerus. Images Fig. 1 Fig. 2 Fig. 3 Fig. 4 PMID:2050566

  16. Population Coding of Forelimb Joint Kinematics by Peripheral Afferents in Monkeys

    PubMed Central

    Umeda, Tatsuya; Seki, Kazuhiko; Sato, Masa-aki; Nishimura, Yukio; Kawato, Mitsuo; Isa, Tadashi

    2012-01-01

    Various peripheral receptors provide information concerning position and movement to the central nervous system to achieve complex and dexterous movements of forelimbs in primates. The response properties of single afferent receptors to movements at a single joint have been examined in detail, but the population coding of peripheral afferents remains poorly defined. In this study, we obtained multichannel recordings from dorsal root ganglion (DRG) neurons in cervical segments of monkeys. We applied the sparse linear regression (SLiR) algorithm to the recordings, which selects useful input signals to reconstruct movement kinematics. Multichannel recordings of peripheral afferents were performed by inserting multi-electrode arrays into the DRGs of lower cervical segments in two anesthetized monkeys. A total of 112 and 92 units were responsive to the passive joint movements or the skin stimulation with a painting brush in Monkey 1 and Monkey 2, respectively. Using the SLiR algorithm, we reconstructed the temporal changes of joint angle, angular velocity, and acceleration at the elbow, wrist, and finger joints from temporal firing patterns of the DRG neurons. By automatically selecting a subset of recorded units, the SLiR achieved superior generalization performance compared with a regularized linear regression algorithm. The SLiR selected not only putative muscle units that were responsive to only the passive movements, but also a number of putative cutaneous units responsive to the skin stimulation. These results suggested that an ensemble of peripheral primary afferents that contains both putative muscle and cutaneous units encode forelimb joint kinematics of non-human primates. PMID:23112841

  17. ANALYSIS OF THE PATTERN AND MECHANISM OF ELBOW INJURIES RELATED TO ARMBAR-TYPE ARMLOCKS IN JIU-JITSU FIGHTERS.

    PubMed

    Almeida, Thiago Bernardo Carvalho DE; Dobashi, Eiffel Tsuyoshi; Nishimi, Alexandre Yukio; Almeida, Eduardo Bernardo DE; Pascarelli, Luciano; Rodrigues, Luciano Miller Reis

    2017-01-01

    The objective of this study was to analyze elbow injuries and their probable mechanism in Jiu-Jitsu fighters resulting from the armbar-type armlock. We evaluated 5 high-performance Jiu-Jitsu fighters from the Gracie Elite gym who were injured during a tournament. All were healthy males with a mean age of 28.8 years. The right arm was involved in three patients (60%). The athletes were followed for approximately 4.6 months, and pain was present in all cases. Clinical examination of the elbow was performed immediately after the injury and when magnetic resonance imaging (MRI) was performed. The radiography showed no changes. Clinical examination detected specific tender points on the medial and anterior topography of the elbows, but no ligamentous instability of the elbow was seen during dynamic testing. The main MRI findings were injury to the common flexor tendon and the ulnar collateral ligament, bone contusion of the distal humerus and olecranon, and joint effusion. The main pattern of injury indicated by the MRI in the athletes was injury to the medial elbow complex. The primary mechanism that determined the injury was most likely elbow hyperextension applied with the forearm in neutral position of forearm. Level of Evidence IV, Case Series.

  18. ANALYSIS OF THE PATTERN AND MECHANISM OF ELBOW INJURIES RELATED TO ARMBAR-TYPE ARMLOCKS IN JIU-JITSU FIGHTERS

    PubMed Central

    ALMEIDA, THIAGO BERNARDO CARVALHO DE; DOBASHI, EIFFEL TSUYOSHI; NISHIMI, ALEXANDRE YUKIO; ALMEIDA, EDUARDO BERNARDO DE; PASCARELLI, LUCIANO; RODRIGUES, LUCIANO MILLER REIS

    2017-01-01

    ABSTRACT Objective: The objective of this study was to analyze elbow injuries and their probable mechanism in Jiu-Jitsu fighters resulting from the armbar-type armlock. Methods: We evaluated 5 high-performance Jiu-Jitsu fighters from the Gracie Elite gym who were injured during a tournament. All were healthy males with a mean age of 28.8 years. The right arm was involved in three patients (60%). The athletes were followed for approximately 4.6 months, and pain was present in all cases. Clinical examination of the elbow was performed immediately after the injury and when magnetic resonance imaging (MRI) was performed. The radiography showed no changes. Clinical examination detected specific tender points on the medial and anterior topography of the elbows, but no ligamentous instability of the elbow was seen during dynamic testing. Results: The main MRI findings were injury to the common flexor tendon and the ulnar collateral ligament, bone contusion of the distal humerus and olecranon, and joint effusion. Conclusion: The main pattern of injury indicated by the MRI in the athletes was injury to the medial elbow complex. The primary mechanism that determined the injury was most likely elbow hyperextension applied with the forearm in neutral position of forearm. Level of Evidence IV, Case Series. PMID:29081707

  19. Triple management of cubitus valgus deformity complicating neglected nonunion of fractures of lateral humeral condyle in children: a case series.

    PubMed

    Abed, Yasser; Nour, Khaled; Kandil, Yasser Roshdy; El-Negery, Abed

    2018-02-01

    Long standing nonunion of the lateral humeral condyle (LHC) usually results in elbow pain and instability with progressive cubitus valgus and tardy ulnar neuritis. Surgical treatment of long standing nonunion is still a controversial issue due to the reported complications, such as stiffness, loss of elbow motion, and avascular necrosis of the LHC fragment. In this study, we reported the outcomes of treatment of cubitus valgus deformity in long standing nonunion of the LHC in children treated with combined triple management (fixation of the nonunion site, dome corrective osteotomy, and anterior transposition of ulnar nerve) through a modified para-triceptal approach. We evaluated ten patients with cubitus valgus deformity more than 20 degrees after neglected nonunion of the lateral humeral condyle more than 24 months. Only childern with post-operative follow up more than 24 months were included in this study. All patients were evaluated clinically, radio logically, and by pre- and post-operative functional evaluation using Mayo elbow performance score. For evaluation of ulnar nerve affection, the Akahori's system was used. There were six females and four males with the average age of 7.7 years at operation. The left elbow was affected in six patients and the right elbow was affected in four patients. The average time between fracture of the LHC and operation was 40.3 months with average post-operative follow up of 44.3 months. The average carrying angle of the healthy side was 5.5 degrees and pre-operative carrying angle of the affected side was 33.5 degrees. The average post-operative carrying angle of the affected side was 6.1 degrees. The improvement of the carrying angle at the last follow up was found statistically significant (p < 0.05). All six patients that had pre-operative various degrees of ulnar nerve affection had completely improved at last follow up. The osteotomy site united in an average time of 43 days, whereas the LHC nonunion site united in an average time of 77.2 days. The osteotomy site united in significantly less time than the LHC non-union site (p < 0.05). The correlation between time since injury and time of union of LHC non-union site was significant (p < 0.05). Post-operative elbow range of motion was not changed in five patients, slightly decreased in four patients, and increased in one patient. Three patients had an average 6.7 degrees (range; 5-10) loss of the last degrees of flexion. One patient developed extension lag of 10 degrees. The mean elbow range of motion (ROM) pre-operatively was 139 ± 4.6 degrees while the mean post-operative ROM was 138 ± 5.3 degrees. The difference was found to be statistically insignificant (p > 0.05). The mean pre-operative Mayo elbow performance score was poor 55 ± 9.7, four patients had fair score, and six had poor score. The mean post-operative Mayo elbow performance score was excellent 92.5 ± 10, six patients had excellent score, and four had good score. The improvement of the Mayo score at the last follow up was found to be statistically significant (p < 0.05). No intra-operative complications were recorded during any of the procedures and no patient developed a wound or pin track infection post-operatively. At the last follow up, none of the patients had developed avascular necrosis of the LHC. Preservation of the blood supply of the nonunited fragment is the key to successful management. This combined technique successfully addresses different aspects of the problem simultaneously and provides a durable solution without deterioration of the results over time. The para-triceptal approach provided excellent exposure of both sides of the elbow with minimal disruption of the triceps muscle.

  20. Exposure of the Distal Humerus Using a Triceps Hemi-peel Approach

    DTIC Science & Technology

    2014-05-14

    kin and Deshmukh .17 A posterior midline incision is made over the elbow, and the skin and subcutaneous tissue are reflected medially and laterally...approach, as described by Deakin and Deshmukh ,17 reflects the triceps insertion in a lateral to medial direction and releas- es the anconeus insertion to...semiconstrained total elbow arthro- plasty. J Bone Joint Surg Am. 2000; 82:1379- 1386. 17. Deakin DE, Deshmukh SC. The triceps-flex- or carpi ulnaris (TRIFCU

  1. Effective utilization of gravity during arm downswing in keystrokes by expert pianists.

    PubMed

    Furuya, S; Osu, R; Kinoshita, H

    2009-12-01

    The present study investigated a skill-level-dependent interaction between gravity and muscular force when striking piano keys. Kinetic analysis of the arm during the downswing motion performed by expert and novice piano players was made using an inverse dynamic technique. The corresponding activities of the elbow agonist and antagonist muscles were simultaneously recorded using electromyography (EMG). Muscular torque at the elbow joint was computed while excluding the effects of gravitational and motion-dependent interaction torques. During descending the forearm to strike the keys, the experts kept the activation of the triceps (movement agonist) muscle close to the resting level, and decreased anti-gravity activity of the biceps muscle across all loudness levels. This suggested that elbow extension torque was produced by gravity without the contribution of agonist muscular work. For the novices, on the other hand, a distinct activity in the triceps muscle appeared during the middle of the downswing, and its amount and duration were increased with increasing loudness. Therefore, for the novices, agonist muscular force was the predominant contributor to the acceleration of elbow extension during the downswing. We concluded that a balance shift from muscular force dependency to gravity dependency for the generation of a target joint torque occurs with long-term piano training. This shift would support the notion of non-muscular force utilization for improving physiological efficiency of limb movement with respect to the effective use of gravity.

  2. Long term changes of the throwing arm of former elite javelin throwers.

    PubMed

    Schmitt, H; Hansmann, H J; Brocai, D R; Loew, M

    2001-05-01

    The aim of this study was to determine long term changes in shoulder and elbow joints of former elite javelin throwers. Twenty-one elite javelin throwers were examined at an average of 19 years after the end of their high performance phase. Mean age at examination was 50 years. Functional assessment of both shoulders was determined by the Constant-score. The shoulder of the throwing arm was examined by magnetic resonance imaging. Both elbow joints were examined clinically and radiographically. Five athletes complained about transient shoulder pain in their throwing arm affecting activities of daily living, fourteen athletes had a deficit of internal rotation of at least ten degrees. Constant-scores of throwing arms were six points lower than those of non-throwing arms (P < 0.05). Complete ruptures and partial tears of the rotator cuff were frequent. Three athletes complained about transient elbow pain in their throwing arm affecting activities of daily living; ten athletes had a deficit of extension of more than five degrees. All dominant elbows had advanced arthrotic alterations (osteophytes, sclerosis) compared to the non-dominant side. Athletes who trained with weights of more than 3 kg had a significantly higher risk of degenerative changes than athletes who did not (P < 0.01). We therefore recommend to avoid throwing training with weights of more than 3 kg.

  3. Manual of Structural Kinesiology. Eighth Edition.

    ERIC Educational Resources Information Center

    Thompson, Clem W.

    This manual is intended for use in college-level courses in structural kinesiology; mechanical kinesiology is introduced only briefly. The first chapter introduces the bases for structural kinesiology. Subsequent chapters are organized according to the areas of the body to be studied (e.g., the shoulder girdle, the shoulder joint, the elbow joint,…

  4. [Coordination patterns assessed by a continuous measure of joints coupling during upper limb repetitive movements].

    PubMed

    Draicchio, F; Silvetti, A; Ranavolo, A; Iavicoli, S

    2008-01-01

    We analyzed the coordination patterns between elbow, shoulder and trunk in a motor task consisting of reaching out, picking up a cylinder, and transporting it back by using the Dynamical Systems Theory and calculating the continuous relative phase (CRP), a continuous measure of the coupling between two interacting joints. We used an optoelectronic motion analysis system consisting of eight infra-red ray cameras to detect the movements of nine skin-mounted markers. We calculated the root square of the adjusted coefficient of determination, the coefficient of multiple correlation (CMC), in order to investigate the repeatability of the joints coordination. The data confirm that the CNS establishes both synergic (i.e. coupling between shoulder and trunk on the frontal plane) and hierarchical (i.e. coupling between elbow-shoulder-trunk on the horizontal plane) relationships among the available degrees of freedom to overcome the complexity due to motor redundancy. The present study describes a method to investigate the organization of the kinematic degrees of freedom during upper limb multi-joint motor tasks that can be useful to assess upper limb repetitive movements.

  5. A New Approach for Human Forearm Motion Assist by Actuated Artificial Joint-An Inner Skeleton Robot

    NASA Astrophysics Data System (ADS)

    Kundu, Subrata Kumar; Kiguchi, Kazuo; Teramoto, Kenbu

    In order to help the physical activities of the elderly or physically disabled persons, we propose a new concept of a power-assist inner skeleton robot (i.e., actuated artificial joint) that is supposed to assist the human daily life motion from inside of the human body. This paper presents an implantable 2 degree of freedom (DOF) inner skeleton robot that is designed to assist human elbow flexion-extension motion and forearm supination-pronation motion for daily life activities. We have developed a prototype of the inner skeleton robot that is supposed to assist the motion from inside of the body and act as an actuated artificial joint. The proposed system is controlled based on the activation patterns of the electromyogram (EMG) signals of the user's muscles by applying fuzzy-neuro control method. A joint actuator with angular position sensor is designed for the inner skeleton robot and a T-Mechanism is proposed to keep the bone arrangement similar to the normal human articulation after the elbow arthroplasty. The effectiveness of the proposed system has been evaluated by experiment.

  6. Kinetics of throwing arm joints and the trunk motion during an overarm distance throw by skilled Japanese elementary school boys.

    PubMed

    Kobayashi, Yasuto; Ae, Michiyoshi; Miyazaki, Akiyo; Fujii, Norihisa; Iiboshi, Akira; Nakatani, Hideki

    2016-09-01

    The purpose of this study was to investigate joint kinetics of the throwing arms and role of trunk motion in skilled elementary school boys during an overarm distance throw. Throwing motions of 42 boys from second, fourth, and sixth grade were videotaped with three high-speed cameras operating at 300 fps. Seven skilled boys from each grade were selected on the basis of throwing distance for three-dimensional kinetic analysis. Joint forces, torques, and torque powers of the throwing arm joints were calculated from reconstructed three-dimensional coordinate data smoothed at cut-off frequencies of 10.5-15 Hz and by the inverse dynamics method. Throwing distance and ball velocity significantly increased with school grade. The angular velocity of elbow extension before ball release increased with school grade, although no significant increase between the grades was observed in peak extension torque of elbow joint. The joint torque power of shoulder internal/external rotation tended to increase with school grade. When teaching the overarm throw, elementary school teachers should observe large backward twisting of trunk during the striding phase and should keep in mind that young children, such as second graders (age 8 years), will be unable to effectively utilise shoulder external/internal rotation during the throwing phase.

  7. Morphological integration in the forelimb of musteloid carnivorans

    PubMed Central

    Fabre, Anne-Claire; Goswami, Anjali; Peigné, Stéphane; Cornette, Raphaël

    2014-01-01

    The forelimb forms a functional unit that allows a variety of behaviours and needs to be mobile, yet at the same time stable. Both mobility and stability are controlled, amongst others, at the level of the elbow joint. This joint is composed of the humero-ulnar articulation, mainly involved during parasagittal movements; and the radio-ulnar articulation, mainly allowing rotation. In contrast, the humero-radial articulation allows both movements of flexion–extension and rotation. Here, we study the morphological integration between each bone of the forelimb at the level of the entire arm, as well as at the elbow joint, in musteloid carnivorans. To do so, we quantitatively test shape co-variation using surface 3D geometric morphometric data. Our results show that morphological integration is stronger for bones that form functional units. Different results are obtained depending on the level of investigation: for the entire arm, results show a greater degree of shape co-variation between long bones of the lower arm than between the humerus and either bone of the lower arm. Thus, at this level the functional unit of the lower arm is comprised of the radius and ulna, permitting rotational movements of the lower arm. At the level of the elbow, results display a stronger shape co-variation between bones allowing flexion and stability (humerus and ulna) than between bones allowing mobility (ulna and radius and humerus and radius). Thus, the critical functional unit appears to be the articulation between the humerus and ulna providing the stability of the joint. PMID:24836555

  8. Effect of knee joint icing on knee extension strength and knee pain early after total knee arthroplasty: a randomized cross-over study.

    PubMed

    Holm, Bente; Husted, Henrik; Kehlet, Henrik; Bandholm, Thomas

    2012-08-01

    To investigate the acute effect of knee joint icing on knee extension strength and knee pain in patients shortly after total knee arthroplasty. A prospective, single-blinded, randomized, cross-over study. A fast-track orthopaedic arthroplasty unit at a university hospital. Twenty patients (mean age 66 years; 10 women) scheduled for primary unilateral total knee arthroplasty. The patients were treated on two days (day 7 and day 10) postoperatively. On one day they received 30 minutes of knee icing (active treatment) and on the other day they received 30 minutes of elbow icing (control treatment). The order of treatments was randomized. Maximal knee extension strength (primary outcome), knee pain at rest and knee pain during the maximal knee extensions were measured 2-5 minutes before and 2-5 minutes after both treatments by an assessor blinded for active or control treatment. The change in knee extension strength associated with knee icing was not significantly different from that of elbow icing (knee icing change (mean (1 SD)) -0.01 (0.07) Nm/kg, elbow icing change -0.02 (0.07) Nm/kg, P = 0.493). Likewise, the changes in knee pain at rest (P = 0.475), or knee pain during the knee extension strength measurements (P = 0.422) were not different between treatments. In contrast to observations in experimental knee effusion models and inflamed knee joints, knee joint icing for 30 minutes shortly after total knee arthroplasty had no acute effect on knee extension strength or knee pain.

  9. Development of a Cadaveric Model for Arthrocentesis.

    PubMed

    MacIver, Melissa A; Johnson, Matthew

    2015-01-01

    This article reports the development of a novel cadaveric model for future use in teaching arthrocentesis. In the clinical setting, animal safety is essential and practice is thus limited. Objectives of the study were to develop and compare a model to an unmodified cadaver by injecting one of two types of fluids to increase yield. The two fluids injected, mineral oil (MO) and hypertonic saline (HS), were compared to determine any difference on yield. Lastly, aspiration immediately after (T1) or three hours after (T2) injection were compared to determine any effect on diagnostic yield. Joints used included the stifle, elbow, and carpus in eight medium dog cadavers. Arthrocentesis was performed before injection (control) and yield measured. Test joints were injected with MO or HS and yield measured after range of motion (T1) and three hours post injection to simulate lab preparation (T2). Both models had statistically significantly higher yield compared with the unmodified cadaver in all joints at T1 and T2 (p<.05) with the exception of HST2 carpus. T2 aspiration had a statistically significant lower yield when compared to T1HS carpus, T1HS elbow, and T1MO carpus. Overall, irrespective of fluid volume or type, percent yield was lower in T2 compared to T1. No statistically significant difference was seen between HS and MO in most joints with the exception of MOT1 stifle and HST2 elbow. Within the time frame assessed, both models were acceptable. However, HS arthrocentesis models proved appropriate for student trial due to the difficult aspirations with MO.

  10. Spasticity Measurement Based on Tonic Stretch Reflex Threshold in Children with Cerebral Palsy Using the PediAnklebot.

    PubMed

    Germanotta, Marco; Taborri, Juri; Rossi, Stefano; Frascarelli, Flaminia; Palermo, Eduardo; Cappa, Paolo; Castelli, Enrico; Petrarca, Maurizio

    2017-01-01

    Nowadays, objective measures are becoming prominent in spasticity assessment, to overcome limitations of clinical scales. Among others, Tonic Stretch Reflex Threshold (TSRT) showed promising results. Previous studies demonstrated the validity and reliability of TSRT in spasticity assessment at elbow and ankle joints in adults. Purposes of the present study were to assess: (i) the feasibility of measuring TSRT to evaluate spasticity at the ankle joint in children with Cerebral Palsy (CP), and (ii) the correlation between objective measures and clinical scores. A mechatronic device, the pediAnklebot, was used to impose 50 passive stretches to the ankle of 10 children with CP and 3 healthy children, to elicit muscles response at 5 different velocities. Surface electromyography, angles, and angular velocities were recorded to compute dynamic stretch reflex threshold; TSRT was computed with a linear regression through angles and angular velocities. TSRTs for the most affected side of children with CP resulted into the biomechanical range (95.7 ± 12.9° and 86.7 ± 17.4° for Medial and Lateral Gastrocnemius, and 75.9 ± 12.5° for Tibialis Anterior). In three patients, the stretch reflex was not elicited in the less affected side. TSRTs were outside the biomechanical range in healthy children. However, no correlation was found between clinical scores and TSRT values. Here, we demonstrated the capability of TSRT to discriminate between spastic and non-spastic muscles, while no significant outcomes were found for the dorsiflexor muscle.

  11. Compromised encoding of proprioceptively determined joint angles in older adults: the role of working memory and attentional load.

    PubMed

    Goble, Daniel J; Mousigian, Marianne A; Brown, Susan H

    2012-01-01

    Perceiving the positions and movements of one's body segments (i.e., proprioception) is critical for movement control. However, this ability declines with older age as has been demonstrated by joint angle matching paradigms in the absence of vision. The aim of the present study was to explore the extent to which reduced working memory and attentional load influence older adult proprioceptive matching performance. Older adults with relatively HIGH versus LOW working memory ability as determined by backward digit span and healthy younger adults, performed memory-based elbow position matching with and without attentional load (i.e., counting by 3 s) during target position encoding. Even without attentional load, older adults with LOW digit spans (i.e., 4 digits or less) had larger matching errors than younger adults. Further, LOW older adults made significantly greater errors when attentional loads were present during proprioceptive target encoding as compared to both younger and older adults with HIGH digit span scores (i.e., 5 digits or greater). These results extend previous position matching results that suggested greater errors in older adults were due to degraded input signals from peripheral mechanoreceptors. Specifically, the present work highlights the role cognitive factors play in the assessment of older adult proprioceptive acuity using memory-based matching paradigms. Older adults with LOW working memory appear prone to compromised proprioceptive encoding, especially when secondary cognitive tasks must be concurrently executed. This may ultimately result in poorer performance on various activities of daily living.

  12. Minimum 2-year outcomes and return to sport following resection arthroplasty for the treatment of sternoclavicular osteoarthritis.

    PubMed

    Katthagen, J Christoph; Tahal, Dimitri S; Menge, Travis J; Horan, Marilee P; Millett, Peter J

    2017-02-01

    The aim of this study was to assess the effect of open resection arthroplasty for osteoarthritis of the sternoclavicular (SC) joint on pain levels, functional outcomes, and return to sport. Patients from a single surgeon's practice who underwent open resection arthroplasty (maximum 10-mm resection) for SC osteoarthritis or prearthritic changes between November 2006 and November 2013 were retrospectively reviewed. This was an outcomes study with prospectively collected data. Preoperative and postoperative American Shoulder and Elbow Surgeons score, Quick Disabilities of the Arm, Shoulder, and Hand score, Single Assessment Numeric Evaluation score, several pain scores, and level of sport intensity were assessed. Seventeen SC joints in 16 patients (9 female, 7 male) met inclusion criteria. Mean age at time of surgery way 41.1 years (range, 12-66 years). One patient refused participation in the study. Three SC joint resections (17.7%) required SC joint revision surgery. Minimum 2-year outcomes data were available for 11 of the remaining 13 SC joints (84.6%). The mean time to follow-up was 3.3 years (range, 2.0-8.8 years). Pain at its worst (P = .026), pain at competition (P = .041), the Quick Disabilities of the Arm, Shoulder, and Hand score (P = .034), and the ability to sleep on the affected shoulder (P = .038) showed significant improvement postoperatively. The average postoperative American Shoulder and Elbow Surgeons score was 83.3. The level of sports participation (P = .042) as well as strength and endurance when participating in sport (P = .039) significantly increased postoperatively. Resection arthroplasty of the medial end of the clavicle in patients with osteoarthritis of the SC joint without instability results in pain reduction, functional improvement, and a high rate of return to sport at midterm follow-up. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. Upper limb joint muscle/tendon injury and anthropometric adaptations in French competitive tennis players.

    PubMed

    Rogowski, Isabelle; Creveaux, Thomas; Genevois, Cyril; Klouche, Shahnaz; Rahme, Michel; Hardy, Philippe

    2016-01-01

    The purpose of this study was to examine the relationship between the upper limb anthropometric dimensions and a history of dominant upper limb injury in tennis players. Dominant and non-dominant wrist, forearm, elbow and arm circumferences, along with a history of dominant upper limb injuries, were assessed in 147 male and female players, assigned to four groups based on location of injury: wrist (n = 9), elbow (n = 25), shoulder (n = 14) and healthy players (n = 99). From anthropometric dimensions, bilateral differences in circumferences and in proportions were calculated. The wrist group presented a significant bilateral difference in arm circumference, and asymmetrical bilateral proportions between wrist and forearm, as well as between elbow and arm, compared to the healthy group (6.6 ± 3.1% vs. 4.9 ± 4.0%, P < 0.01; -3.6 ± 3.0% vs. -0.9 ± 2.9%, P < 0.05; and -2.2 ± 2.2% vs. 0.1 ± 3.4%, P < 0.05, respectively). The elbow group displayed asymmetrical bilateral proportions between forearm and arm compared to the healthy group (-0.4 ± 4.3% vs. 1.5 ± 4.0%, P < 0.01). The shoulder group showed significant bilateral difference in elbow circumference, and asymmetrical bilateral proportions between forearm and elbow when compared to the healthy group (5.8 ± 4.7% vs. 3.1 ± 4.8%, P < 0.05 and -1.7 ± 4.5% vs. 1.4 ± 4.3%, P < 0.01, respectively). These findings suggest that players with a history of injury at the upper limb joint present altered dominant upper limb proportions in comparison with the non-dominant side, and such asymmetrical proportions would appear to be specific to the location of injury. Further studies are needed to confirm the link between location of tennis injury and asymmetry in upper limb proportions using high-tech measurements in symptomatic tennis players.

  14. Assessment of medial elbow laxity by gravity stress radiography: comparison of valgus stress radiography with gravity and a Telos stress device.

    PubMed

    Harada, Mikio; Takahara, Masatoshi; Maruyama, Masahiro; Nemoto, Tadanobu; Koseki, Kazuhiko; Kato, Yoshihiro

    2014-04-01

    Valgus instability was reported to be higher with the elbow in 60° of flexion, rather than in 30° of flexion, although there are no studies using valgus stress radiography by gravity (gravity radiography) with the elbow in 60° of flexion. Fifty-seven patients with medial elbow pain participated. For both elbows, valgus stress radiography by use of a Telos device (Telos radiography) and gravity radiography, with the elbow in 60° of flexion, were performed for the assessment of medial elbow laxity. In both radiographs, the medial elbow joint space (MJS) on the affected side was compared with that on the opposite side, and the increase in the MJS on the affected side was assessed. For the Telos radiographs, the mean MJS was 4.7 mm on the affected side and 4.0 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.7 mm. For the gravity radiographs, the mean MJS was 5.0 mm on the affected side and 4.2 mm on the opposite side, with the mean increase in the MJS on the affected side being 0.8 mm. There were significant correlations between the Telos and gravity radiographs in the MJS on the affected side, the MJS on the opposite side, and the increase in the MJS on the affected side (respectively, P < .0001). There was also a high level of intraobserver and interobserver reliability for the assessment of the gravity radiographs. Gravity radiography is useful for assessment of medial elbow laxity, similar to Telos radiography. Copyright © 2014 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  15. Effect of elbow and forearm position on contact pressure between the extensor origin and the lateral side of the capitellum.

    PubMed

    Tanaka, Yoshitaka; Aoki, Mitsuhiro; Izumi, Tomoki; Wada, Takuro; Fujimiya, Mineko; Yamashita, Toshihiko

    2011-01-01

    Bone-to-tendon contact in the origin of the common extensor tendons is considered to be one of the causes of lateral epicondylitis. Some factors, including elbow and forearm position, varus stress to the elbow, or contraction of the wrist extensor tendons, are considered to affect this bone-to-tendon contact. However, no studies have evaluated the effect of the elbow and forearm position on bone-tendon interface. The purpose of this study is to evaluate the effect of the position of the elbow and forearm on the contact pressure of the tendinous origin of the common wrist and finger extensors. We used 8 fresh cadaveric upper extremities. Contact pressure between the origin of the common extensor tendons and the lateral side of the capitellum was measured with a pressure sensor and was compared among various conditions, including elbow flexion angle (0°, 30°, 60°, and 90°), forearm rotation position (neutral and 81.5° pronation position), and varus stress load of the elbow (none, gravity on the forearm, and gravity on the forearm +1.96 Nm). Contact pressure was also measured during tension force of the extensor carpi radialis longus, extensor carpi radialis brevis, and extensor digitorum communis by 0, 9.8, and 19.6 N. Contact pressure was significantly increased with the elbow extension position, forearm pronation position, and varus stress to the elbow under tension of the extensor carpi radialis longus or extensor carpi radialis brevis. This study provides data about the amount of contact pressure between bone and tendon at the origin of the common extensor tendons in the elbow. This information may lead to a better understanding of, and better treatment for, lateral epicondylitis. Copyright © 2011. Published by Elsevier Inc.

  16. Elbow reconstruction with a pedicled thoracodorsal artery perforator flap after excision of an upper-extremity giant hairy nevus.

    PubMed

    Oksüz, Sinan; Ulkür, Ersin; Tuncer, Serhan; Sever, Celalettin; Karagöz, Hüseyin

    2013-04-01

    The complexity of managing large soft-tissue defects at the elbow region by conventional techniques arises from the difficulty of providing sufficient tissue with adequate elasticity and durability. Reconstruction options that allow early mobilisation and avoid the risk of functional loss should be considered to achieve defect closure at the elbow region. A 21-year-old man presented with a congenital giant hairy nevus on his left upper extremity. The nevus was excised and the resulting raw surface after the excision was covered with a split-thickness skin graft except for the elbow region. The elbow was covered in one stage with an ipsilateral 24 cm long pedicled thoracodorsal artery perforator (TDAP) flap. The follow-up examination 3 years after total reconstruction demonstrated durable elbow support provided by the TDAP flap. The patient revealed no complaint considering pain or sensitivity even when exposed to mechanical stress. Split-thickness skin grafting of the large superficial defects is almost always possible; however, impairment of the function on joint areas due to gradual contraction and skin graft propensity to ulcers under mechanical stresses can be devastating. The elbow is a weight-bearing area of the body. Elbow defects require durable and thin soft-tissue coverage and the tissue cover must possess excellent elastic properties to re-establish elbow mobility. The TDAP flap is an ideal choice for elbow soft-tissue defects. The longest pedicle length reported for the TDAP flap is 23 cm. In our case, the pedicle length was 24 cm and it was possible to transfer this flap to the elbow on its pedicle. A pedicled TDAP skin flap so as to provide elbow coverage in one stage is a useful choice to retain in one's armamentarium. Copyright © 2012 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  17. The "moving valgus stress test" for medial collateral ligament tears of the elbow.

    PubMed

    O'Driscoll, Shawn W M; Lawton, Richard L; Smith, Adam M

    2005-02-01

    The diagnosis of a painful partial tear of the medial collateral ligament in overhead-throwing athletes is challenging, even for experienced elbow surgeons and despite the use of sophisticated imaging techniques. The "moving valgus stress test" is an accurate physical examination technique for diagnosis of medial collateral ligament attenuation in the elbow. Cohort study (diagnosis); Level of evidence, 2. Twenty-one patients underwent surgical intervention for medial elbow pain due to medial collateral ligament insufficiency or other abnormality of chronic valgus overload, and they were assessed preoperatively with an examination called the moving valgus stress test. To perform the moving valgus stress test, the examiner applies and maintains a constant moderate valgus torque to the fully flexed elbow and then quickly extends the elbow. The test is positive if the medial elbow pain is reproduced at the medial collateral ligament and is at maximum between 120 degrees and 70 degrees. The moving valgus stress test was highly sensitive (100%, 17 of 17 patients) and specific (75%, 3 of 4 patients) when compared to assessment of the medial collateral ligament by surgical exploration or arthroscopic valgus stress testing. The mean shear range (ie, the arc within which pain was produced with the moving valgus stress test) was 120 degrees to 70 degrees. The mean angle at which pain was at a maximum was 90 degrees of elbow flexion. The moving valgus stress test is an accurate physical examination technique that, when performed and interpreted correctly, is highly sensitive for medial elbow pain arising from the medial collateral ligament.

  18. [Viscosity determination of synovial fluids from the canine hip and elbow joint as well as the human knee joint].

    PubMed

    Helms, Gabriele; Rittmann, Pia; Wefstaedt, Patrick; Windhagen, Henning; Pressel, Thomas; Behrens, Bernd-Arno; Nolte, Ingo

    2008-01-01

    The development of pathological changes in both human and canine hip joints is mainly caused by a lack of synovial fluid lubrication. This results in an increased joint abrasion. Even after implantation of joint prosthesis, inadequate lubrication can lead to abrasion in the tribological pair. This can finally result in aseptic loosening of the prosthesis. In spite of the enormous number of studies that have been performed on human, only little knowledge about the tribological properties of the joints in dogs is available in the literature. For this reason the viscosities of synovial fluid, derived from physiological and pathologically changed canine elbow joints were measured. The viscosities were determined by the use of a cone-plate viscometer at different temperatures and shear rates. The obtained values were compared with the viscosity values of pathologically changed synovial fluids from human knee joints as well as with pathological samples from the canine hip joint. The results show that the viscosity values vary within a series of measurements and are inversely proportional to the temperature of the sample and the shear rate. The differences between the average viscosities of canine and human synovial fluids taken from pathologically changed joints are below 4% (22.5 s(-1) at theta1 = 25 degrees C). The findings of this study are being implemented in a FE-Model for the computation of actual forces in the hip joint during different movements. This would represent a contribution to an improved prosthetic treatment of canine and human hips.

  19. A New Technique for Compensating Joint Limits in a Robot Manipulator

    NASA Technical Reports Server (NTRS)

    Litt, Jonathan; Hickman, Andre; Guo, Ten-Huei

    1996-01-01

    A new robust, optimal, adaptive technique for compensating rate and position limits in the joints of a six degree-of-freedom elbow manipulator is presented. In this new algorithm, the unmet demand as a result of actuator saturation is redistributed among the remaining unsaturated joints. The scheme is used to compensate for inadequate path planning, problems such as joint limiting, joint freezing, or even obstacle avoidance, where a desired position and orientation are not attainable due to an unrealizable joint command. Once a joint encounters a limit, supplemental commands are sent to other joints to best track, according to a selected criterion, the desired trajectory.

  20. Arthroscopic management of the painful total elbow arthroplasty

    PubMed Central

    Bain, Gregory I

    2015-01-01

    Background Failure of total elbow arthroplasty is more common than after other major joint arthroplasties and is often a result of aseptic loosening, peri-prosthetic infection, fracture and instability. Infection can be a devastating complication, yet there are no established guidelines for the pre-operative diagnosis of total elbow peri-prosthetic infection. This is because pre-operative clinical, radiographic and biochemical tests are often unreliable. Methods Using three case examples, a standardized protocol for the clinical and arthroscopic assessment of the painful total elbow arthroplasty is described. This is used to provide a mechanical and microbiological diagnosis of the patient’s pain. Results There have been no complications resulting from the use of this technique in the three patients described, nor in any other patient to date. Conclusions The staged protocol described in the present study, utilizing arthroscopic assessment, has refined the approach to the painful total elbow arthroplasty because it directly influences the definitive surgical management of the patient. It is recommended that other surgeons follow the principles outlined in the present study when faced with this challenging problem. PMID:27583000

  1. Augmented effects of EMG biofeedback interfaced with virtual reality on neuromuscular control and movement coordination during reaching in children with cerebral palsy.

    PubMed

    Yoo, Ji Won; Lee, Dong Ryul; Cha, Young Joo; You, Sung Hyun

    2017-01-01

    The purpose of the present study was to compare therapeutic effects of an electromyography (EMG) biofeedback augmented by virtual reality (VR) and EMG biofeedback alone on the triceps and biceps (T:B) muscle activity imbalance and elbow joint movement coordination during a reaching motor taskOBJECTIVE: To compare therapeutic effects of an electromyography (EMG) biofeedback augmented by virtual reality (VR) and EMG biofeedback alone on the triceps and biceps muscle activity imbalance and elbow joint movement coordination during a reaching motor task in normal children and children with spastic cerebral palsy (CP). 18 children with spastic CP (2 females; mean±standard deviation = 9.5 ± 1.96 years) and 8 normal children (3 females; mean ± standard deviation = 9.75 ± 2.55 years) were recruited from a local community center. All children with CP first underwent one intensive session of EMG feedback (30 minutes), followed by one session of the EMG-VR feedback (30 minutes) after a 1-week washout period. Clinical tests included elbow extension range of motion (ROM), biceps muscle strength, and box and block test. EMG triceps and biceps (T:B) muscle activity imbalance and reaching movement acceleration coordination were concurrently determined by EMG and 3-axis accelerometer measurements respectively. Independent t-test and one-way repeated analysis of variance (ANOVA) were performed at p < 0.05. The one-way repeated ANOVA was revealed to be significantly effective in elbow extension ROM (p = 0.01), biceps muscle strength (p = 0.01), and box and block test (p = 0.03). The one-way repeated ANOVA also revealed to be significantly effective in the peak triceps muscle activity (p = 0.01). However, one-way repeated ANOVA produced no statistical significance in the composite 3-dimensional movement acceleration coordination data (p = 0.12). The present study is a first clinical trial that demonstrated the superior benefits of the EMG biofeedback when augmented by virtual reality exercise games in children with spastic CP. The augmented EMG and VR feedback produced better neuromuscular balance control in the elbow joint than the EMG biofeedback alone.

  2. Dislocation: First Aid

    MedlinePlus

    ... or a collision during contact or high-speed sports. Dislocation usually involves the body's larger joints. In adults, the most common site of the injury is the shoulder. In children, it's the elbow. ...

  3. [The elbow joint - a diagnostic challenge : anatomy, biomechanics, and pathology].

    PubMed

    Schueller-Weidekamm, C; Kainberger, F

    2008-12-01

    The elbow is one of the most commonly injured joints in sports activities. In particular, weight lifters, golfers, tennis players, and pitchers are affected. Injuries in sports involving overhead throwing are commonly based on the pathophysiologic model of valgus extension overload syndrome. The injuries are commonly complex and demand a good knowledge of the symptoms, the exact anatomy, and the biomechanics to arrive at a precise radiologic diagnosis. The characteristic patterns of injury that occur in specific sports activities are related to a combination of increased varus or valgus and extension or flexion overload that results in tensile forces and/or compression and shear stress. Acute symptoms are frequently based on chronic degeneration of the tendons and ligamentous structures due to repetitive microtrauma from overuse syndrome.

  4. Tennis players show a lower coactivation of the elbow antagonist muscles during isokinetic exercises.

    PubMed

    Bazzucchi, Ilenia; Riccio, Maria Elena; Felici, Francesco

    2008-10-01

    Previous studies have suggested that muscle coactivation could be reduced by a recurrent activity (training, daily activities). If this was correct, skilled athletes should show a specific muscle activation pattern with a low level of coactivation of muscles which are typically involved in their discipline. In particular, the aim of this study was to verify the hypothesis that the amount of antagonist activation of biceps brachii (BB) and triceps brachii (TB) is different between tennis players and non-players individuals during maximal isokinetic contractions. Ten young healthy men and eight male tennis players participated in the study. The surface electromyographic signals (sEMG) were recorded from the BB and TB muscles during three maximal voluntary isometric contractions (MVC) of elbow flexors and extensors and a set of three maximal elbow flexions and extensions at 15 degrees , 30 degrees , 60 degrees , 120 degrees , 180 degrees and 240 degrees /s. Normalized root mean square (RMS) of sEMG was calculated as an index of sEMG amplitude. Antagonist activation (%RMSmax) of TB was significantly lower in tennis players (from 14.0+/-7.9% at MVC to 16.3+/-8.9% at 240 degrees /s) with respect to non-players (from 27.7+/-19.7% at MVC to 38.7+/-17.6% at 240 degrees /s) at all angular velocities. Contrary to non-players, tennis players did not show any difference in antagonist activation between BB and TB muscles. Tennis players, with a constant practice in controlling forces around the elbow joint, learn how to reduce coactivation of muscles involved in the control of this joint. This has been shown by the lower antagonist muscular activity of triceps brachii muscle during isokinetic elbow flexion found in tennis players with respect to non-players.

  5. Effectiveness of the Saline Load Test in Diagnosis of Traumatic Elbow Arthrotomies

    DTIC Science & Technology

    2011-11-01

    load test for the knee, using 80 knees in patients undergoing elective knee arthroscopy . A fixed volume of 60 mL of saline was injected while observing... Arthroscopy . 1990;6:100–103. 10. Voit GA, Irvine G, Beals RK. Saline load test for penetration of periarticular lacerations. J Bone Joint Surg Br. 1996;78:732...318. 12. Plancher KD, Shariff KB. Basics of elbow arthroscopy : setup, portals, and technique. Tech Orthop. 2006;21:239–249. 13. Marvel JE, Marsh HO

  6. Acupuncture for lateral epicondylitis (tennis elbow): study protocol for a randomized, practitioner-assessor blinded, controlled pilot clinical trial.

    PubMed

    Shin, Kyung-Min; Kim, Joo-Hee; Lee, Seunghoon; Shin, Mi-Suk; Kim, Tae-Hun; Park, Hyo-Ju; Lee, Min-Hee; Hong, Kwon-Eui; Lee, Seungdeok; Choi, Sun-Mi

    2013-06-14

    Lateral epicondylitis is the most frequent cause of pain around the elbow joint. It causes pain in the region of the elbow joint and results in dysfunction of the elbow and deterioration of the quality of life. The purpose of this study is to compare the effects of ipsilateral acupuncture, contralateral acupuncture and sham acupuncture on lateral epicondylitis. Forty-five subjects with lateral epicondylitis will be randomized into three groups: the ipsilateral acupuncture group, contralateral acupuncture group and the sham acupuncture group. The inclusion criteria will be as follows: (1) age between 19 and 65 years with pain due to one-sided lateral epicondylitis that persisted for at least four weeks, (2) with tenderness on pressure limited to regions around the elbow joint, (3) complaining of pain during resistive extension of the middle finger or the wrist, (4) with average pain of NRS 4 or higher during the last one week at a screening visit and (5) voluntarily agree to this study and sign a written consent. Acupuncture treatment will be given 10 times in total for 4 weeks to all groups. Follow up observations will be conducted after the completion of the treatment, 8 weeks and 12 weeks after the random assignment. Ipsilateral acupuncture group and contralateral acupuncture group will receive acupuncture on LI4, TE5, LI10, LI11, LU5, LI12 and two Ashi points. The sham acupuncture group will receive treatment on acupuncture points not related to the lateral epicondylitis using a non-invasive method. The needles will be maintained for 20 minutes. The primary outcome will be differences in the visual analogue scale (VAS) for elbow pain between the groups. The secondary outcome will be differences in patient-rated tennis elbow evaluation (PRTEE), pain-free/maximum grip strength (Dynamometer), pressure pain threshold, clinically relevant improvement, patient global assessment, and the EQ-5D. The data will be analyzed with the paired t-test and ANCOVA (P <0.05). The results of this study will allow evaluation of contralateral acupuncture from two aspects. First, if the contralateral acupuncture shows the effects similar to ipsilateral acupuncture, this will establish clinical basis for contralateral acupuncture. Second, if the effects of contralateral acupuncture are not comparable to the effects of ipsilateral acupuncture, but are shown to be similar to the effects of the sham acupuncture, we can establish the basis for using the same acupoints of the unaffected side as a control in acupuncture clinical studies. This trial has been registered with the 'Clinical Research Information Service (CRIS)', Republic of Korea: KCT0000628.

  7. Acupuncture for lateral epicondylitis (tennis elbow): study protocol for a randomized, practitioner-assessor blinded, controlled pilot clinical trial

    PubMed Central

    2013-01-01

    Background Lateral epicondylitis is the most frequent cause of pain around the elbow joint. It causes pain in the region of the elbow joint and results in dysfunction of the elbow and deterioration of the quality of life. The purpose of this study is to compare the effects of ipsilateral acupuncture, contralateral acupuncture and sham acupuncture on lateral epicondylitis. Methods/design Forty-five subjects with lateral epicondylitis will be randomized into three groups: the ipsilateral acupuncture group, contralateral acupuncture group and the sham acupuncture group. The inclusion criteria will be as follows: (1) age between 19 and 65 years with pain due to one-sided lateral epicondylitis that persisted for at least four weeks, (2) with tenderness on pressure limited to regions around the elbow joint, (3) complaining of pain during resistive extension of the middle finger or the wrist, (4) with average pain of NRS 4 or higher during the last one week at a screening visit and (5) voluntarily agree to this study and sign a written consent. Acupuncture treatment will be given 10 times in total for 4 weeks to all groups. Follow up observations will be conducted after the completion of the treatment, 8 weeks and 12 weeks after the random assignment. Ipsilateral acupuncture group and contralateral acupuncture group will receive acupuncture on LI4, TE5, LI10, LI11, LU5, LI12 and two Ashi points. The sham acupuncture group will receive treatment on acupuncture points not related to the lateral epicondylitis using a non-invasive method. The needles will be maintained for 20 minutes. The primary outcome will be differences in the visual analogue scale (VAS) for elbow pain between the groups. The secondary outcome will be differences in patient-rated tennis elbow evaluation (PRTEE), pain-free/maximum grip strength (Dynamometer), pressure pain threshold, clinically relevant improvement, patient global assessment, and the EQ-5D. The data will be analyzed with the paired t-test and ANCOVA (P <0.05). Discussion The results of this study will allow evaluation of contralateral acupuncture from two aspects. First, if the contralateral acupuncture shows the effects similar to ipsilateral acupuncture, this will establish clinical basis for contralateral acupuncture. Second, if the effects of contralateral acupuncture are not comparable to the effects of ipsilateral acupuncture, but are shown to be similar to the effects of the sham acupuncture, we can establish the basis for using the same acupoints of the unaffected side as a control in acupuncture clinical studies. Trial registration This trial has been registered with the ‘Clinical Research Information Service (CRIS)’, Republic of Korea: KCT0000628. PMID:23768129

  8. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  9. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  10. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  11. 38 CFR 4.45 - The joints.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... movement (due to muscle injury, disease or injury of peripheral nerves, divided or lengthened tendons, etc... the purpose of rating disability from arthritis, the shoulder, elbow, wrist, hip, knee, and ankle are...

  12. Obturator externus abscess in a 9-year-old child: A case report and literature review.

    PubMed

    de Bodman, Charlotte; Ceroni, Dimitri; Dufour, Justine; Crisinel, Pierre-Alex; Bregou-Bourgeois, Aline; Zambelli, Pierre-Yves

    2017-03-01

    Obturator pyomyositis is a rare condition in children. Diagnosis is often delayed because of its rarity, and the vagaries of its presentation cause it to be easily be missed. Physicians should therefore familiarize themselves with this condition and consider it as a possible differential diagnosis in patients presenting with an acutely painful hip. Inflammatory syndrome is also frequent among sufferers and the MRI is a very sensitive diagnostic tool for obturator pyomyositis. Additionally, joint fluid aspirations and blood cultures are also useful in identifying the pathogen. The appropriate antibiotic therapy provides a rapid regression of symptoms during the early stage of pyomyositis. In cases of MRI-confirmed abscess, surgical treatment is indicated. Our report focuses on a case of obturator pyomyositis in a 9-year-old boy. The child was febrile for 5 days and could only manage to walk a few steps. His hip range of motion was restricted in all directions. In addition, the patient had presented pain and swelling of his right elbow for a day, with a restriction of motion in the joint. There was a clear inflammatory syndrome. A diagnosis of hip and elbow septic arthritis was suspected, and the child underwent joint aspiration of the both cited joints. The aspiration of the elbow returned pus. Conversely, no effusion was found in the hip aspiration. The administration of empiric intravenous antibiotherapy was started. An MRI revealed an osteomyelitis of the ischio-pubic area associated with a subperiosteal abscess. Subsequently, 3 days after elbow arthrotomy, a surgical treatment was performed on the patient's right hip in order to evacuate the subperiosteal abscess and muscular collection because of the persistence of the patient's symptoms and inflammatory syndrome despite susceptible intravenous antibiotics. Postsurgery the patient showed steady improvement. Such cases demonstrate how diagnosis can be difficult because pelvic pyomyositis is often mistaken for more common pathologies such as septic arthritis, osteomyelitis, or appendicitis. This may delay the diagnosis or refer misdiagnosis. We discuss this rare infection in light of the literature with particular reference to its incidence, clinical features, bacteriological etiology, biological, and radiological presentation, and above all, its treatment.

  13. Functional Mobility Testing: A Novel Method to Create Suit Design Requirements

    NASA Technical Reports Server (NTRS)

    England, Scott A.; Benson, Elizabeth A.; Rajulu, Sudhakar L.

    2008-01-01

    This study was performed to aide in the creation of design requirements for the next generation of space suits that more accurately describe the level of mobility necessary for a suited crewmember through the use of an innovative methodology utilizing functional mobility. A novel method was utilized involving the collection of kinematic data while 20 subjects (10 male, 10 female) performed pertinent functional tasks that will be required of a suited crewmember during various phases of a lunar mission. These tasks were selected based on relevance and criticality from a larger list of tasks that may be carried out by the crew. Kinematic data was processed through Vicon BodyBuilder software to calculate joint angles for the ankle, knee, hip, torso, shoulder, elbow, and wrist. Maximum functional mobility was consistently lower than maximum isolated mobility. This study suggests that conventional methods for establishing design requirements for human-systems interfaces based on maximal isolated joint capabilities may overestimate the required mobility. Additionally, this method provides a valuable means of evaluating systems created from these requirements by comparing the mobility available in a new spacesuit, or the mobility required to use a new piece of hardware, to this newly established database of functional mobility.

  14. Sequences of upper and lower extremity motions in javelin throwing.

    PubMed

    Liu, Hui; Leigh, Steve; Yu, Bing

    2010-11-01

    Javelin throwing is technically demanding. Sequences of upper and lower extremity motions are important for javelin throwing performance. The purpose of this study was to determine the general sequences of upper and lower extremity motions of elite male and female javelin throwers. Three-dimensional kinematic data were collected for 32 female and 30 male elite javelin throwers during competitions. Shoulder, elbow, wrist, hip, knee, ankle, lower trunk, and upper trunk joint and segment angles were reduced for the best trial of each participant. Beginning times of 6 upper extremity and 10 lower extremity joint and segment angular motions were identified. Sequences of the upper and lower extremity motions were determined through statistical analyses. Upper and lower extremity motions of the male and female elite javelin throwers followed specific sequences (P ≤ 0.050). Upper extremity motions of the male and female elite javelin throwers did not follow a proximal-to-distal sequence as suggested in the literature. Male and female elite javelin throwers apparently employed different sequences for upper and lower extremity motions (P < 0.001). Further studies are needed to determine the effects of sequences of upper and lower extremity motions on javelin throwing performance.

  15. Rehabilitation of neglected Monteggia fracture: Dislocations in children.

    PubMed

    Yıldırım, Azad; Nas, Kemal

    2017-11-06

    There are limited studies related to the rehabilitation of neglected Monteggia fracture-dislocations. This study reports the results of the rehabilitation of neglected Monteggia fractures and dislocations and the best treatment options available. Thirteen children were rehabilitated between 2009 and 2012. A retrospective chart review was conducted to record the following: age, gender, anatomic region of fractures, time delay from symptom onset to fracture, Bado classification, Mayo Elbow Performance Index (MEPI) which includes pain, range of motion and daily life comfort, surgeries, length of hospitalization, location and pattern of fracture, length of follow-up and complications. The study group included thirteen children and adolescents; eleven males and two females with a mean age of 8.5 (range 2-15) years. According to the Bado classification, 11 patients had type 1, one had type 3 and one had type 4 fracture-dislocations. For Mayo Elbow Performance Index (MEPI) scales, patients that were less than ten years old had greater mean scores. Two patients had superficial infection, one had subluxation, one had osteoarthritis, one had delayed bone union and two had rigidity at the elbow. The goals of elbow rehabilitation following Neglected Monteggia cases include restoring function by restoring motion and muscle performance; influencing scar remodeling and preventing joint contracture; and restoring or maintaining joint stability. Patients aged younger than 10 years and intervals of less than one-year, between trauma and diagnosis, as well as early and effective rehabilitation were found as important parameters regarding favorable outcomes.

  16. Intra-articular injection with triamcinolone hexacetonide in patients with rheumatoid arthritis: prospective assessment of goniometry and joint inflammation parameters.

    PubMed

    Furtado, Rita Nely Vilar; Machado, Flávia Soares; Luz, Karine Rodrigues da; Santos, Marla Francisca Dos; Konai, Monique Sayuri; Lopes, Roberta Vilela; Natour, Jamil

    To evaluate local joint variables after intra-articular injection with triamcinolone hexacetonide in rheumatoid arthritis patients. We blindly and prospectively (baseline, 1, 4, 12 and 24 weeks) evaluated metacarpophalangeal, wrist, elbow, shoulder, knee and ankle joints after triamcinolone hexacetonide intra-articular injection by the following outcome measures: visual analogue scale 0-10cm (VAS) for rest pain (VASR); VAS for movement pain (VASM); VAS for joint swelling (VASSw); flexion (FlexG) and extension (ExtG). 289 patients (635 joints) were studied. VASSw (p<0.001) and VASR (0.001

  17. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    PubMed

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  18. Body position reproducibility and joint alignment stability criticality on a muscular strength research device

    NASA Astrophysics Data System (ADS)

    Nunez, F.; Romero, A.; Clua, J.; Mas, J.; Tomas, A.; Catalan, A.; Castellsaguer, J.

    2005-08-01

    MARES (Muscle Atrophy Research and Exercise System) is a computerized ergometer for neuromuscular research to be flown and installed onboard the International Space Station in 2007. Validity of data acquired depends on controlling and reducing all significant error sources. One of them is the misalignment of the joint rotation axis with respect to the motor axis.The error induced on the measurements is proportional to the misalignment between both axis. Therefore, the restraint system's performance is critical [1]. MARES HRS (Human Restraint System) assures alignment within an acceptable range while performing the exercise (results: elbow movement:13.94mm+/-5.45, Knee movement: 22.36mm+/- 6.06 ) and reproducibility of human positioning (results: elbow movement: 2.82mm+/-1.56, Knee movement 7.45mm+/-4.8 ). These results allow limiting measurement errors induced by misalignment.

  19. [Intra-articular injections of triamcinolone hexacetonide in rheumatoid arthritis: short and long-term improvement predictors].

    PubMed

    Furtado, Rita Nely Vilar; Machado, Flavia Soares; Luz, Karine Rodrigues da; Santos, Marla Francisca dos; Konai, Monique Sayuri; Lopes, Roberta Vilela; Natour, Jamil

    2015-01-01

    Identify good response predictors to intra-articular injection (IAI) with triamcinolone hexacetonide (TH). This study was carried out in rheumatoid arthritis (RA) patients (American College of Rheumatology criteria) submitted to IAI (mono, pauci or polyarticular injection). A "blinded" observer prospectively evaluated joints at one week (T1), four weeks (T4), twelve weeks (T12) and 24 weeks (T24) after IAI. Outcome measurements included Visual Analogue Scale (0-10 cm) at rest, in movement and for swollen joints. Clinical, demographic and variables related to injection at baseline were analyzed according to IAI response. We studied 289 patients with RA (635 joints) with a mean age of 48.7 years (±10.68), 48.5% of them Caucasians, VAS for global pain=6.52 (±1.73). Under univariate analysis, the variables relating the best responses following IAI (improvement > 70%) were: "elbow and metacarpophalangeal (MCP) IAI, and functional class II". Under multivariate analysis, "males" and "non-whites" were the predictors with the best response to IAI at T4, while "elbow and MCP IAI", "polyarticular injection", "use of methotrexate" and "higher total dose of TH" obtained the best response at T24. Several predictors of good response to IAI in patients with RA were identified. The best-response predictors for TH IAI of long term were "apply elbow and MCP IAI" and "apply polyarticular injection". Copyright © 2014 Elsevier Editora Ltda. All rights reserved.

  20. Fracture through a geode in the proximal ulna.

    PubMed

    Wordsworth, B P; Mowat, A G; Watson, N A

    1984-05-01

    Chronic joint pain in rheumatoid arthritis may mask that from other causes. Stress fractures, particularly in osteoporotic lower limb bones of such patients, are well described but can still cause diagnostic difficulty. These difficulties were highlighted by a case in which an unusual fracture occurred through a geode in the proximal ulna mimicking an exacerbation of synovitis in the elbow joint.

  1. Weight compensation characteristics of Armeo®Spring exoskeleton: implications for clinical practice and research.

    PubMed

    Perry, Bonnie E; Evans, Emily K; Stokic, Dobrivoje S

    2017-02-17

    Armeo®Spring exoskeleton is widely used for upper extremity rehabilitation; however, weight compensation provided by the device appears insufficiently characterized to fully utilize it in clinical and research settings. Weight compensation was quantified by measuring static force in the sagittal plane with a load cell attached to the elbow joint of Armeo®Spring. All upper spring settings were examined in 5° increments at the minimum, maximum, and two intermediate upper and lower module length settings, while keeping the lower spring at minimum. The same measurements were made for minimum upper spring setting and maximum lower spring setting at minimum and maximum module lengths. Weight compensation was plotted against upper module angles, and slope was analyzed for each condition. The Armeo®Spring design prompted defining the slack angle and exoskeleton balance angle, which, depending on spring and length settings, divide the operating range into different unloading and loading regions. Higher spring tensions and shorter module lengths provided greater unloading (≤6.32 kg of support). Weight compensation slope decreased faster with shorter length settings (minimum length = -0.082 ± 0.002 kg/°; maximum length = -0.046 ± 0.001 kg/°) independent of spring settings. Understanding the impact of different settings on the Armeo®Spring weight compensation should help define best clinical practice and improve fidelity of research.

  2. Effect of a commercially available fish-based dog food enriched with nutraceuticals on hip and elbow dysplasia in growing Labrador retrievers.

    PubMed

    Manfredi, Sabrina; Di Ianni, Francesco; Di Girolamo, Nicola; Canello, Sergio; Gnudi, Giacomo; Guidetti, Gianandrea; Miduri, Francesca; Fabbi, Martina; Daga, Eleonora; Parmigiani, Enrico; Centenaro, Sara; Volta, Antonella

    2018-04-01

    The aim of this study was to evaluate the prevalence of hip and elbow dysplasia in a group of growing Labrador retrievers fed a fish-based diet enriched with nutraceuticals with chondroprotective properties. The puppies ranged from 3 to 12 mo of age and were divided into 2 groups, each fed a different diet. The control diet consisted of a high quality, chicken-based dog food, while the test diet was a fish-based dog food, enriched with nutraceuticals. Hip and elbow joints were radiographed and scored at 6 and 12 mo of age. Overall, 42 dogs completed the study. At 12 mo of age, no differences were found between the groups in the prevalence of hip and elbow dysplasia, although dogs fed the fish-based food enriched with nutraceuticals had a less severe grade of osteoarthritis at 12 mo. It was concluded that the fish-based diet with nutraceuticals did have beneficial effects on the development of severe osteoarthritis.

  3. Advanced servo manipulator

    DOEpatents

    Holt, W.E.; Kuban, D.P.; Martin, H.L.

    1988-10-25

    An advanced servo manipulator has modular parts. Modular motor members drive individual input gears to control shoulder roll, shoulder pitch, elbow pitch, wrist yaw, wrist pitch, wrist roll, and tong spacing. The modules include a support member, a shoulder module for controlling shoulder roll, and a sleeve module attached to the shoulder module in fixed relation thereto. The shoulder roll sleeve module has an inner cylindrical member rotatable relative to the outer cylindrical member, and upon which a gear pod assembly is mounted. A plurality of shafts are driven by the gears, which are in turn driven by individual motor modules to transmit rotary power to control elbow pitch as well as to provide four different rotary shafts across the bendable elbow joint to supply rotary motive power to a wrist member and tong member. 41 figs.

  4. Advanced servo manipulator

    DOEpatents

    Holt, William E.; Kuban, Daniel P.; Martin, H. Lee

    1988-01-01

    An advanced servo manipulator has modular parts. Modular motor members drive individual input gears to control shoulder roll, shoulder pitch, elbow pitch, wrist yaw, wrist pitch, wrist roll, and tong spacing. The modules include a support member, a shoulder module for controlling shoulder roll, and a sleeve module attached to the shoulder module in fixed relation thereto. The shoulder roll sleeve module has an inner cylindrical member rotatable relative to the outer cylindrical member, and upon which a gear pod assembly is mounted. A plurality of shafts are driven by the gears, which are in turn driven by individual motor modules to transmit rotary power to control elbow pitch as well as to provide four different rotary shafts across the bendable elbow joint to supply rotary motive power to a wrist member and tong member.

  5. Comparison of shock transmission and forearm electromyography between experienced and recreational tennis players during backhand strokes.

    PubMed

    Wei, Shun-Hwa; Chiang, Jinn-Yen; Shiang, Tzyy-Yuang; Chang, Hsiao-Yun

    2006-03-01

    To test the hypothesis that recreational tennis players transmit more shock impact from the racket to the elbow joint than experienced tennis players during the backhand stroke. Also, to test whether recreational tennis players used higher electromyographic (EMG) activities in common wrist extensor and flexor around epicondylar region at follow-through phase. A repeated-measure, cross-sectional study. National College of Physical Education and Sports at Taipei, Taiwan. Twenty-four male tennis players with no abnormal forearm musculoskeletal injury participated in the study. According to performance level, subjects were categorized into 2 groups: experienced and recreational. Impact transmission and wrist extensor-flexor EMG for backhand acceleration, impact, and follow-through phases were recorded for each player. An independent t test with a significance level of 0.05 was used to examine mean differences of shock impact and EMG between the 2 test groups. One-way ANOVA associated with Tukey multiple comparisons was used to identify differences among different impact locations and EMG phases. Experienced athletes reduced the racket impact to the elbow joint by 89.2%, but recreational players reduced it by only 61.8%. The largest EMG differences were found in the follow-through phase (P<0.05). Experienced athletes showed that their extensor and flexor EMGs were at submaximal level for follow-through phase, whereas recreational players maintained their flexor and extensor EMGs at either supramaximal or maximal level. Our results support the hypothesis that recreational players transmit more shock impact from the racket to the elbow joint and use larger wrist flexor and extensor EMG activities at follow-through phase of the backhand stroke. Follow-through control is proposed as a critical factor for reduction of shock transmission. Clinicians or trainers should instruct beginners to quickly release their grip tightness after ball-to-racket impact to reduce shock impact transmission to the wrist and elbow.

  6. Intra-articular injuries of the elbow: pitfalls of diagnosis and treatment.

    PubMed Central

    Fowles, J. V.; Rizkallah, R.

    1976-01-01

    Poor results in treating fractures and dislocations about the elbow may be avoided if the surgeon is aware of the possible injuries, examines good radiographs of both elbows, and treats the injury promptly and appropriately. A displaced fracture of the lateral or medial condyle of the humerus should be suspected if there is a flake fracture of the adjoining metaphysis; open reduction and internal fixation give better results than closed reduction. A shear fracture of the capitulum humeri can only be seen on a lateral radiograph; excision of the fragment, followed by mobilization, is sufficient for a good functional result. Dislocation of the elbow in a child may avulse the medial epicondyle, which sometimes lodges in the joint; it is essential to recognize this and remove the fragment without delay to avoid early degenerative arthritis. An apparently isolated fracture of the ulna should alert the surgeon to the possibility of a dislocation of the radial head; the dislocation and the fracture must be reduced and stabilized to conserve elbow function. Images FIG. 1 FIG. 2 FIG. 3 FIG. 4 FIG. 5 FIG. 6 FIG. 7 FIG. 8 PMID:943224

  7. Examination of and intervention for a patient with chronic lateral elbow pain with signs of nerve entrapment.

    PubMed

    Ekstrom, Richard A; Holden, Kari

    2002-11-01

    Lateral elbow pain has several causes, which can make diagnosis difficult. The purpose of this case report is to describe the examination of and the intervention for a patient with chronic lateral elbow pain who had signs of nerve entrapment. The patient was a 43-year-old woman who had right lateral elbow pain for about 4 months, which she attributed to extensive keyboard work on a computer. She had a reduction in joint passive range of motion during "neural tension testing," an examination procedure to detect nerve entrapment. This sign, in combination with other findings, suggested that the patient had a mild entrapment of the deep radial nerve (radial tunnel syndrome). The patient was treated 14 times over a 10-week period with "neural mobilization techniques," which are designed to free nerves for movement; ultrasound; strengthening exercises; and stretching. The patient had minimal symptoms at discharge, was pain-free, and had resumed all activities at a 4-month follow-up visit. Neural tension testing may be a useful examination procedure and mobilization may be useful for intervention for patients who have lateral elbow pain.

  8. A martial arts exploration of elbow anatomy: Ikkyo (Aikido's first teaching).

    PubMed

    Seitz, F C; Olson, G D; Stenzel, T E

    1991-12-01

    The Martial Art of Aikido, based on several effective anatomical principles, is used to subdue a training partner. One of these methods is Ikkyo (First Teaching). According to Saotome, the original intent of Ikkyo was to "break the elbow joint" of an enemy. Nowadays the intent is to secure or pin a training partner to the mat. This investigation focused on examining Ikkyo with the purpose of describing the nerves, bones, and muscles involved in receiving this technique. Particular focus was placed on the locations and sources of the reported pain.

  9. Effects of inactivation of the anterior interpositus nucleus on the kinematic and dynamic control of multijoint movement.

    PubMed

    Cooper, S E; Martin, J H; Ghez, C

    2000-10-01

    We previously showed that inactivating the anterior interpositus nucleus in cats disrupts prehension; paw paths, normally straight and accurate, become curved, hypometric, and more variable. In the present study, we determined the joint kinematic and dynamic origins of this impairment. Animals were restrained in a hammock and trained to reach and grasp a cube of meat from a narrow food well at varied heights; movements were monitored using the MacReflex analysis system. The anterior interpositus nucleus was inactivated by microinjection of the GABA agonist muscimol (0.25-0.5 microgram in 0.5 microliter saline). For each joint, we computed the torque due to gravity, inertial resistance (termed self torque), interjoint interactions (termed interaction torque), and the combined effects of active muscle contraction and passive soft tissue stretch (termed generalized muscle torque). Inactivation produced significant reductions in the amplitude, velocity, and acceleration of elbow flexion. However, these movements continued to scale normally with target height. Shoulder extension was reduced by inactivation but wrist angular displacement and velocity were not. Inactivation also produced changes in the temporal coordination between elbow, shoulder, and wrist kinematics. Dynamic analysis showed that elbow flexion both before and during inactivation was produced by the combined action of muscle and interaction torque, but that the timing depended on muscle torque. Elbow interaction and muscle torques were scaled to target height both before and during inactivation. Inactivation produced significant reductions in elbow flexor interaction and muscle torques. The duration of elbow flexor muscle torque was prolonged to compensate for the reduction in flexor interaction torque. Shoulder extension was produced by extensor interaction and muscle torques both before and during inactivation. Inactivation produced a reduction in shoulder extension, primarily by reduced interaction torque, but without compensation. Wrist plantarflexion, which occurred during elbow flexion, was driven by plantarflexor interaction and gravitational torques both before and during inactivation. Muscle torque acted in the opposite direction with a phase lead to restrain the plantarflexor interaction torque. During inactivation, there was a reduction in plantarflexor interaction torque and a loss of the phase lead of the muscle torque. Our findings implicate the C1/C3 anterior interpositus zone of the cerebellum in the anticipatory control of intersegmental dynamics during reaching, which zone is required for coordinating the motions of the shoulder and wrist with those of the elbow. In contrast, this cerebellar zone does not play a role in scaling the movement to match a target.

  10. Phenotypic hip and elbow dysplasia trends in Rottweilers and Labrador retrievers in South Africa (2007-2015): Are we making progress?

    PubMed

    Kirberger, Robert M

    2017-11-22

    Canine hip and elbow dysplasia are major orthopaedic problems prevalent the world over, and South Africa is no exception. Hip and elbow dysplasia phenotypic status is certified by a number of different radiographic schemes in the world. South Africa uses the Fédération Cynologique Internationale system to certify hips, and the International Elbow Working Group scheme to certify elbows. One way of reducing these often crippling conditions is by selective breeding using only dogs with no or marginal dysplastic joints. In South Africa, only seven breeds, including the Rottweiler, have breeding restrictions for hip dysplasia. There are no such restrictions for elbow dysplasia. This study assessed the prevalence of hip and elbow dysplasia over a 9-year-period in the Rottweiler and the Labrador retriever in South Africa as evaluated by official national scrutineers. Records from 1148 Rottweilers and 909 Labrador retrievers were obtained and were graded as normal or dysplastic, and numerical values were also evaluated. Data were compared between the two breeds, males and females as well as over time and were compared with similar data of the Orthopaedic Foundation for Animals in the United States. The prevalence values for hip dysplasia in Rottweilers and Labrador retrievers were 22% and 31%, respectively, whereas for elbow dysplasia the values were 39% and 19%, respectively. In Labrador retrievers, this incidence was much higher than in the American population. Rottweiler hip and elbow dysplasia numerical scores significantly improved over time, whereas in Labrador retrievers, only hip dysplasia showed a minor but significant improvement. This study proved that prescribing minimum breeding requirements, as in the Rottweiler in this study, significantly improved the breeding stock, suggesting that minimum hip and elbow breeding requirements should be initiated for all breeds at risk of these often crippling conditions.

  11. Prevention of Posttraumatic Contractures with Ketotifen (PERK)

    DTIC Science & Technology

    2017-10-01

    opportunity to design a Phase III RCT on the use of ketotifen in post -traumatic joint contractures. The goal is to design and develop the infrastructure to...Research (CIHR) for the Phase III RCT. 2. KEYWORDS Post -traumatic contractures, elbow fractures, randomized clinical trial, multicenter, ketotifen...application to use ketotifen in post -traumatic joint contracture prevention was submitted to the Division of Pulmonary, Allergy, and Rheumatology

  12. Directionally compliant legs influence the intrinsic pitch behaviour of a trotting quadruped

    PubMed Central

    Lee, David V; Meek, Sanford G

    2005-01-01

    Limb design is well conserved among quadrupeds, notably, the knees point forward (i.e. cranial inclination of femora) and the elbows point back (i.e. caudal inclination of humeri). This study was undertaken to examine the effects of joint orientation on individual leg forces and centre of mass dynamics. Steady-speed trotting was simulated in two quadrupedal models. Model I had the knee and elbow orientation of a quadruped and model II had a reversed leg configuration in which knees point back and elbows point forward. The model's legs showed directional compliance determined by the orientation of the knee/elbow. In both models, forward pointing knees/elbows produced a propulsive force bias, while rearward pointing knees/elbows produced a braking force bias. Hence, model I showed the same pattern of hind-leg propulsion and fore-leg braking observed in trotting animals. Simulations revealed minimal pitch oscillations during steady-speed trotting of model I, but substantially greater and more irregular pitch oscillations of model II. The reduced pitch oscillation of model I was a result of fore-leg and hind-leg forces that reduced pitching moments during early and late stance, respectively. This passive mechanism for reducing pitch oscillations was an emergent property of directionally compliant legs with the fore–hind configuration of model I. Such intrinsic stability resulting from mechanical design can simplify control tasks and lead to more robust running machines. PMID:15817430

  13. Validation of a photography-based goniometry method for measuring joint range of motion.

    PubMed

    Blonna, Davide; Zarkadas, Peter C; Fitzsimmons, James S; O'Driscoll, Shawn W

    2012-01-01

    A critical component of evaluating the outcomes after surgery to restore lost elbow motion is the range of motion (ROM) of the elbow. This study examined if digital photography-based goniometry is as accurate and reliable as clinical goniometry for measuring elbow ROM. Instrument validity and reliability for photography-based goniometry were evaluated for a consecutive series of 50 elbow contractures by 4 observers with different levels of elbow experience. Goniometric ROM measurements were taken with the elbows in full extension and full flexion directly in the clinic (once) and from digital photographs (twice in a blinded random manner). Instrument validity for photography-based goniometry was extremely high (intraclass correlation coefficient: extension = 0.98, flexion = 0.96). For extension and flexion measurements by the expert surgeon, systematic error was negligible (0° and 1°, respectively). Limits of agreement were 7° (95% confidence interval [CI], 5° to 9°) and -7° (95% CI, -5° to -9°) for extension and 8° (95% CI, 6° to 10°) and -7° (95% CI, -5° to -9°) for flexion. Interobserver reliability for photography-based goniometry was better than that for clinical goniometry. The least experienced observer's photographic goniometry measurements were closer to the reference measurements than the clinical goniometry measurements. Photography-based goniometry is accurate and reliable for measuring elbow ROM. The photography-based method relied less on observer expertise than clinical goniometry. This validates an objective measure of patient outcome without requiring doctor-patient contact at a tertiary care center, where most contracture surgeries are done. Copyright © 2012 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  14. Experimental and numerical investigation of centrifugal pumps with asymmetric inflow conditions

    NASA Astrophysics Data System (ADS)

    Mittag, Sten; Gabi, Martin

    2015-11-01

    Most of the times pumps operate off best point states. Reasons are changes of operating conditions, modifications, pollution and wearout or erosion. As consequences non-rotational symmetric flows, transient operational conditions, increased risk of cavitation, decrease of efficiency and unpredictable wearout can appear. Especially construction components of centrifugal pumps, in particular intake elbows, contribute to this matter. Intake elbows causes additional losses and secondary flows, hence non-rotational velocity distributions as intake profile to the centrifugal pump. As a result the impeller vanes experience permanent changes of the intake flow angle and with it transient flow conditions in the blade channels. This paper presents the first results of a project, experimentally and numerically investigating the consequences of non-rotational inflow to leading edge flow conditions of a centrifugal pump. Therefore two pumpintake- elbow systems are compared, by only altering the intake elbow geometry: a common single bended 90° elbow and a numerically optimized elbow (improved regarding rotational symmetric inflow conditions and friction coefficient). The experiments are carried out, using time resolved stereoscopic PIV on a full acrylic pump with refractions index matched (RIM) working fluid. This allows transient investigations of the flow field simultaneously for all blade leading edges. Additional CFD results are validated and used to further support the investigation i.e. for comparing an analog pump system with ideal inflow conditions.

  15. Tendinitis

    MedlinePlus

    ... of a tendon. Tendinitis usually happens after repeated injury to an area such as the wrist or ankle. It causes pain and soreness around a joint. Some common forms of tendinitis are named after the sports that increase their risk. They include tennis elbow, ...

  16. Peak velocity of elbow joint during hair combing activity for normal subject

    NASA Astrophysics Data System (ADS)

    Che-Nan, Hasyatun; Rambely, Azmin Sham

    2018-04-01

    Study of upper limb movements is very important for clinical assessment and diagnosis purposes. Thus it requires the analysis of motion. Therefore this study intend to investigate peak velocity of elbow joint during hair-combing activity. Twenty healthy subjects with three trials and age range 20 - 59 years old (n = 60) performed a complete cycle of hand reaching, forward transport, combing, back transport and returning the hand to its initial position. This activity was analyzed using Vicon motion-analysis system, which consisted of three infra-red and high speed cameras. Mean total movement times was recorded at 5.2s for the whole phases. Peak velocities during reaching and forward transport were found to be decreasing in value for the healthy subject. This obtained results provide information on kinematic analysis especially on movement times and peak velocities for clinical, assessment and diagnosis purposes.

  17. Development of an Upper Limb Power Assist System Using Pneumatic Actuators for Farming Lift-up Motion

    NASA Astrophysics Data System (ADS)

    Yagi, Eiichi; Harada, Daisuke; Kobayashi, Masaaki

    A power assist system has lately attracted considerable attention to lifting-up an object without low back pain. We have been developing power assist systems with pneumatic actuators for the elbow and shoulder to farming support of lifting-up a bag of rice weighing 30kg. This paper describes the mechanism and control method of this power assist system. The pneumatic rotary actuator supports shoulder motion, and the air cylinder supports elbow motion. In this control method, the surface electromyogram(EMG) signals are used as input information of the controller. The joint support torques of human are calculated based on the antigravity term of necessary joint torques, which are estimated on the dynamics of a human approximated link model. The experimental results show the effectiveness of the proposed mechanism and control method of the power assist system.

  18. Evaluation of the reliability and validity of the Persian version of Patient-Rated Elbow Evaluation questionnaire.

    PubMed

    Farazdaghi, Mohammad Reza; Mansoori, Ali; Vosoughi, Omid; Kordi Yoosefinejad, Amin

    2017-05-01

    Elbow joint pathologies are highly prevalent in Persian-speaking countries. A reliable low-cost method like an appropriate questionnaire is mandatory for the early diagnosis of elbow joint disorders. Among designed questionnaires, Patient-Rated Elbow Evaluation (PREE) is an accepted commonly used scale evaluating pain and dysfunction of the patients. The aims of the study were to cross-culturally adapt and also to identify the psychometric properties of the Persian PREE. The original version of the PREE was translated and cross-culturally adapted to Persian according to the guidelines by Beaton et al. Seventy-three patients and thirty-nine healthy people were enrolled in the study. Test-retest reliability and internal consistency were evaluated using ICC, Cronbach's alpha, and item-total correlation, respectively. Construct validity was investigated using Disability of Arm, Shoulder, and Hand (DASH) questionnaire and physical component scale of SF-36 (PCS). To determine a cutoff point for discriminating patients from non-patients, receiver operating characteristic curve was plotted. The Persian PREE displayed high internal consistency (Cronbach's alpha = 0.91) and had acceptable ICC values in the subscales and total score (ICC > 0.90). A positive moderate correlation with DASH (r = 0.66, P < 0.001) and a negative moderate correlation with PCS of SF-36 (r = -0.44, P < 0.001) were observed. The cutoff point equal to 13.16 was determined for Persian PREE. The Persian PREE exhibited promising validity and reliability. The findings supported its applicability in clinical situations that were consistent with the original version.

  19. Upper limb kinetic analysis of three sitting pivot wheelchair transfer techniques.

    PubMed

    Koontz, Alicia M; Kankipati, Padmaja; Lin, Yen-Sheng; Cooper, Rory A; Boninger, Michael L

    2011-11-01

    The objective of this study was to investigate differences in shoulder, elbow and hand kinetics while performing three different SPTs that varied in terms of hand and trunk positioning. Fourteen unimpaired individuals (8 male and 6 female) performed three variations of sitting pivot transfers in a random order from a wheelchair to a level tub bench. Two transfers involved a forward flexed trunk (head-hips technique) and the third with the trunk remaining upright. The two transfers involving a head hips technique were performed with two different leading hand initial positions. Motion analysis equipment recorded upper body movements and force sensors recorded hand reaction forces. Shoulder and elbow joint and hand kinetics were computed for the lift phase of the transfer. Transferring using either of the head hips techniques compared to the trunk upright style of transferring resulted in reduced superior forces at the shoulder (P<0.002), elbow (P<0.004) and hand (P<0.013). There was a significant increase in the medial forces in the leading elbow (P=0.049) for both head hip transfers and the trailing hand for the head hip technique with the arm further away from the body (P<0.028). The head hip techniques resulted in higher shoulder external rotation, flexion and extension moments compared to the trunk upright technique (P<0.021). Varying the hand placement and trunk positioning during transfers changes the load distribution across all upper limb joints. The results of this study may be useful for determining a technique that helps preserve upper limb function overtime. Published by Elsevier Ltd.

  20. Uncontrolled Manifold Reference Feedback Control of Multi-Joint Robot Arms

    PubMed Central

    Togo, Shunta; Kagawa, Takahiro; Uno, Yoji

    2016-01-01

    The brain must coordinate with redundant bodies to perform motion tasks. The aim of the present study is to propose a novel control model that predicts the characteristics of human joint coordination at a behavioral level. To evaluate the joint coordination, an uncontrolled manifold (UCM) analysis that focuses on the trial-to-trial variance of joints has been proposed. The UCM is a nonlinear manifold associated with redundant kinematics. In this study, we directly applied the notion of the UCM to our proposed control model called the “UCM reference feedback control.” To simplify the problem, the present study considered how the redundant joints were controlled to regulate a given target hand position. We considered a conventional method that pre-determined a unique target joint trajectory by inverse kinematics or any other optimization method. In contrast, our proposed control method generates a UCM as a control target at each time step. The target UCM is a subspace of joint angles whose variability does not affect the hand position. The joint combination in the target UCM is then selected so as to minimize the cost function, which consisted of the joint torque and torque change. To examine whether the proposed method could reproduce human-like joint coordination, we conducted simulation and measurement experiments. In the simulation experiments, a three-link arm with a shoulder, elbow, and wrist regulates a one-dimensional target of a hand through proposed method. In the measurement experiments, subjects performed a one-dimensional target-tracking task. The kinematics, dynamics, and joint coordination were quantitatively compared with the simulation data of the proposed method. As a result, the UCM reference feedback control could quantitatively reproduce the difference of the mean value for the end hand position between the initial postures, the peaks of the bell-shape tangential hand velocity, the sum of the squared torque, the mean value for the torque change, the variance components, and the index of synergy as well as the human subjects. We concluded that UCM reference feedback control can reproduce human-like joint coordination. The inference for motor control of the human central nervous system based on the proposed method was discussed. PMID:27462215

  1. The Relationship of Throwing Arm Mechanics and Elbow Varus Torque: Within-Subject Variation for Professional Baseball Pitchers Across 82,000 Throws.

    PubMed

    Camp, Christopher L; Tubbs, Travis G; Fleisig, Glenn S; Dines, Joshua S; Dines, David M; Altchek, David W; Dowling, Brittany

    2017-11-01

    Likely due to the high level of strain exerted across the elbow during the throwing motion, elbow injuries are on the rise in baseball. To identify at-risk athletes and guide postinjury return-to-throw programs, a better understanding of the variables that influence elbow varus torque is desired. To describe the within-subject relationship between elbow varus torque and arm slot and arm rotation in professional baseball pitchers. Descriptive laboratory study. A total of 81 professional pitchers performed 82,000 throws while wearing a motusBASEBALL sensor and sleeve. These throws represented a combination of throw types, such as warm-up/catch, structured long-toss, bullpen throwing from a mound, and live game activity. Variables recorded for each throw included arm slot (angle of the forearm relative to the ground at ball release), arm speed (maximal rotational velocity of the forearm), arm rotation (maximal external rotation of the throwing arm relative to the ground), and elbow varus torque. Linear mixed-effects models and likelihood ratio tests were used to estimate the relationship between elbow varus torque and arm slot, arm speed, and arm rotation within individual pitchers. All 3 metrics-arm slot (χ 2 = 428, P < .001), arm speed (χ 2 = 57,683, P < .001), and arm rotation (χ 2 = 1392, P < .001)-were found to have a significant relationship with elbow varus torque. Within individual athletes, a 1-N.m increase in elbow varus torque was associated with a 13° decrease in arm slot, a 116 deg/s increase in arm speed, and an 8° increase in arm rotation. Elbow varus torque increased significantly as pitchers increased their arm rotation during the arm cocking phase, increased the rotational velocity of their arm during the arm acceleration phase of throwing, and decreased arm slot at ball release. Thus, shoulder flexibility, arm speed, and elbow varus torque (and likely injury risk) are interrelated and should be considered collectively when treating pitchers. It is well established that elbow varus torque is related to ulnar collateral ligament injuries in overhead throwers. This study describes the relationship of arm slot, arm speed, and arm rotation to elbow varus torque in an attempt to identify modifiable risk factors for injury.

  2. Wheelchair propulsion kinematics in beginners and expert users: influence of wheelchair settings.

    PubMed

    Gorce, P; Louis, N

    2012-01-01

    Biomechanical studies have linked the handrim wheelchair propulsion with a prevalence of upper limb musculoskeletal disorders. The purpose of this study was to examine the influence of the wheelchair settings on upper limb kinematics during wheelchair propulsion. Recordings were made under various wheelchair configuration conditions to understand the effect of wheelchair settings on kinematics parameters such shoulder, elbow and wrist angles. Ten experts and ten beginners' subjects propelled an experimental wheelchair on a roller ergometer system at a comfortable speed. Twelve wheelchair configurations were tested. Kinematics were recorded for each configuration. Based on the hand position relatively to the handrim, the main kinematic parameters of wheelchair propulsion were investigated on the whole propulsion cycle and a key event such as handrim contact and release. Compared to the beginner subjects, all the experts' subjects generally present higher joint amplitude and propulsion speeds. Seat height and antero-posterior axle position influence usage of the hand-rim, timing parameters and configurations of upper limb joints. Results seem to confirm that low and backward seat position allow a greater efficiency. Nevertheless, according that proximity of joint limit is a well known factor of musculoskeletal disorders, our results let us think that too low and backward seat position, increasing joints positions and amplitudes, could increase the risk of upper limb injuries in relation with manual wheelchair propulsion. Kinematic differences highlight that future studies on wheelchair propulsion should only be done with impaired experienced subjects. Furthermore, this study provides indications on how wheelchair settings can be used for upper limb injury prevention. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Upper-limb kinematic reconstruction during stroke robot-aided therapy.

    PubMed

    Papaleo, E; Zollo, L; Garcia-Aracil, N; Badesa, F J; Morales, R; Mazzoleni, S; Sterzi, S; Guglielmelli, E

    2015-09-01

    The paper proposes a novel method for an accurate and unobtrusive reconstruction of the upper-limb kinematics of stroke patients during robot-aided rehabilitation tasks with end-effector machines. The method is based on a robust analytic procedure for inverse kinematics that simply uses, in addition to hand pose data provided by the robot, upper arm acceleration measurements for computing a constraint on elbow position; it is exploited for task space augmentation. The proposed method can enable in-depth comprehension of planning strategy of stroke patients in the joint space and, consequently, allow developing therapies tailored for their residual motor capabilities. The experimental validation has a twofold purpose: (1) a comparative analysis with an optoelectronic motion capturing system is used to assess the method capability to reconstruct joint motion; (2) the application of the method to healthy and stroke subjects during circle-drawing tasks with InMotion2 robot is used to evaluate its efficacy in discriminating stroke from healthy behavior. The experimental results have shown that arm angles are reconstructed with a RMSE of 8.3 × 10(-3) rad. Moreover, the comparison between healthy and stroke subjects has revealed different features in the joint space in terms of mean values and standard deviations, which also allow assessing inter- and intra-subject variability. The findings of this study contribute to the investigation of motor performance in the joint space and Cartesian space of stroke patients undergoing robot-aided therapy, thus allowing: (1) evaluating the outcomes of the therapeutic approach, (2) re-planning the robotic treatment based on patient needs, and (3) understanding pathology-related motor strategies.

  4. Preseason Perceived Physical Capability and Previous Injury.

    PubMed

    Sciascia, Aaron; Haegele, Lauren E; Lucas, Jean; Uhl, Timothy L

    2015-09-01

    Patient opinion about the ability to perform athletic maneuvers is important after injury; however, prospective assessment of self-perceived physical capability for athletes before the beginning of a season is lacking. To perform a descriptive analysis of knee, shoulder, and elbow self-perceived measures of physical capability specific to athletics and to compare the measures between athletes with and without a history of injury. Cross-sectional study. Preparticipation physical examinations. A total of 738 collegiate athletes (486 men, 251 women; age = 19 ± 1 years) were administered questionnaires after receiving medical clearance to participate in their sports. Of those athletes, 350 reported a history of injury. Athletes self-reported a history of knee, shoulder, or elbow injury. Perceived physical capability of the 3 joints was evaluated using the Knee Injury and Osteoarthritis Outcome Score Sport and Recreation Function and Knee-Related Quality of Life subscales and the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow Score. We conducted nonparametric analysis to determine if scores differed between athletes with and without a history of injury. Median values for the Knee Injury and Osteoarthritis Outcome Score Sports and Recreation Function and Knee-Related Quality of Life subscales and the Kerlan-Jobe Orthopaedic Clinic Shoulder and Elbow Score for all athletes were 100. Median values for perceived physical capability of athletes with a history of injury were 3 to 12 points lower for each questionnaire before the start of the season (P < .001). Our study provided descriptive values for individual perceived knee, shoulder, and elbow physical capability of collegiate athletes participating in 19 sports. Athletes who did not report previous injuries perceived their physical capabilities to be nearly perfect, which could set the goal for these athletes to return to participation after injury. Athletes reporting previous injuries perceived less physical capability before the competitive season. Self-assessment of joint-specific capability may supplement preseason physical examinations, identifying particular athletes needing further monitoring or care during a season.

  5. Velocity associated characteristics of force production in college weight lifters.

    PubMed

    Kanehisa, H; Fukunaga, T

    1999-04-01

    To determine velocity specific isokinetic forces and cross sectional areas of reciprocal muscle groups in Olympic weight lifters. The cross sectional area of the flexor or extensor muscles of the elbow or knee joint was determined by a B-mode ultrasonic apparatus in 34 college weight lifters and 31 untrained male subjects matched for age. Maximum voluntary force produced in the flexion and extension of the elbow and knee joints was measured on an isokinetic dynamometer at 60, 180, and 300 degrees/s. The average cross sectional area was 31-65% higher, and the force was 19-62% higher in weight lifters than in the untrained subjects. The ratio of force to cross sectional area was the same in both groups. The weight lifters showed a lower velocity associated decline in force than untrained subjects in the elbow and knee flexors but not in the extensors. These results indicate that for muscle contractions with velocities between 60 degrees/s and 300 degrees/s the difference in isokinetic force between weight lifters and untrained subjects can be primarily attributed to the difference in the muscle cross sectional area. However, the lower velocity associated decline in force implies that weight lifters may have a higher force per cross sectional area than untrained subjects at velocities above 300 degrees/s.

  6. Capitellar Erosion after Radial Head Arthroplasty: A Comparative Biomechanical Study of Operated Radial Head Fractures on Cadaveric Specimens.

    PubMed

    Chytas, I D; Antonopoulos, C; Cheva, A; Givissis, P

    2018-03-23

    We asked whether either open reduction and internal fixation (ORIF) or radial head arthroplasty (RHA), common techniques used for the confrontation of displaced or comminuted radial head fractures, are correlated with cartilage wear of the capitulum. We hypothesized that neither ORIF nor RHA are correlated with capitellar cartilage wear. On 5 cadaveric elbow specimens, osteotomies were employed to simulate radial head comminuted fractures followed with ORIF by Herbert screws. Radial heads were also excised from other 5 cadaveric elbow specimens and were replaced by metallic monopolar implants. Finally 2 elbows were not operated and used as a control group. Custom-made rotary machines, working unstoppably, generated 700.000 pronation and supination forearm movements at an 110° arc of motion. The elbow joints were examined with pre- and postoperative Magnetic Resonance Imaging (MRI) scans and the articular surfaces of the capitula were resected and sent for histopathology study. In the 2 cadaveric elbows of the control group and the 4 elbows treated with ORIF no cartilage damage was found. The fifth one displayed cartilage fissures which were classified according to International Cartilage Repair Society (ICRS) grading system as grade I cartilage damage. On the contrary, all 5 elbows treated with RHA sustained complete cartilage loss, exposure of the subchondral bone and were classified as ICRS grade IV cartilage damage. Our study suggests that metallic monopolar RHA after a displaced or comminuted radial head fracture carries a high risk of rapidly evolving cartilage loss of the capitulum. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  7. Control of multi-joint arm movements for the manipulation of touch in keystroke by expert pianists

    PubMed Central

    2010-01-01

    Background Production of a variety of finger-key touches in the piano is essential for expressive musical performance. However, it remains unknown how expert pianists control multi-joint finger and arm movements for manipulating the touch. The present study investigated differences in kinematics and kinetics of the upper-limb movements while expert pianists were depressing a key with two different touches: pressed and struck. The former starts key-depression with the finger-tip contacting the key, whereas the latter involves preparatory arm-lift before striking the key. To determine the effect of individual muscular torque (MUS) as well as non-muscular torques on joint acceleration, we performed a series of inverse and forward dynamics computations. Results The pressed touch showed smaller elbow extension velocity, and larger shoulder and finger flexion velocities during key-depression compared with the struck touch. The former touch also showed smaller elbow extension acceleration directly attributed to the shoulder MUS. In contrast, the shoulder flexion acceleration induced by elbow and wrist MUS was greater for the pressed touch than the struck touch. Towards the goal of producing the target finger-key contact dynamics, the pressed and struck touches effectively took advantage of the distal-to-proximal and proximal-to-distal inter-segmental dynamics, respectively. Furthermore, a psychoacoustic experiment confirmed that a tone elicited by the pressed touch was perceived softer than that by the struck touch. Conclusion The present findings suggest that manipulation of tone timbre depends on control of inter-segmental dynamics in piano keystroke. PMID:20630085

  8. The biomechanical evaluation of a novel 3-strand docking technique for ulnar collateral ligament reconstruction in the elbow.

    PubMed

    Williams, Phillip N; McGarry, Michelle H; Ihn, Hansel; Schulz, Brian M; Limpisvasti, Orr; ElAttrache, Neal S; Lee, Thay Q

    2018-05-07

    The original 2-strand docking technique for elbow ulnar collateral ligament reconstruction has recently been modified to use a 3-strand graft. To date, no biomechanical study has compared the 2 techniques. We hypothesized that the 3-strand docking technique would restore valgus laxity to its native state, with comparable load-to-failure characteristics to the 2-strand docking technique. Sixteen fresh cadaveric elbows were matched to the corresponding contralateral side from the same individual to create 8 matched pairs and were then randomized to undergo ulnar collateral ligament reconstruction using either the 2- or 3-strand technique. Valgus laxity and rotation measurements were quantified using a MicroScribe 3DLX digitizer at various flexion angles for the native state, transected state, and 1 of the 2 tested reconstructed ligaments. Each reconstruction was then tested to failure. Valgus laxity for the intact state at elbow flexion angles of 30°, 60°, 90°, and 120° was 7° ± 2°, 7° ± 2°, 6° ± 1°, and 5° ± 2°, respectively. These values were similar to those of both reconstruction techniques. On load-to-failure testing, there was no significant difference in any parameter recorded. Yield torques for the 3- and 2-strand reconstructions were 13.4 ± 4.80 N/m and 11.8 ± 4.76 N/m, respectively (P = .486). The ultimate torques were 15.7 ± 6.10 N/m and 14.4 ± 5.58 N/m for the 3- and 2-strand techniques, respectively (P = .582). The 3-strand docking technique was able to restore valgus laxity to the native state, with similar load-to-failure characteristics to the 2-strand docking technique. Copyright © 2018 Journal of Shoulder and Elbow Surgery Board of Trustees. All rights reserved.

  9. Biomechanical loading on the upper extremity increases from single key tapping to directional tapping.

    PubMed

    Qin, Jin; Trudeau, Matthieu; Katz, Jeffrey N; Buchholz, Bryan; Dennerlein, Jack T

    2011-08-01

    Musculoskeletal disorders associated with computer use span the joints of the upper extremity. Computing typically involves tapping in multiple directions. Thus, we sought to describe the loading on the finger, wrist, elbow and shoulder joints in terms of kinematic and kinetic difference across single key switch tapping to directional tapping on multiple keys. An experiment with repeated measures design was conducted. Six subjects tapped with their right index finger on a stand-alone number keypad placed horizontally in three conditions: (1) on single key switch (the number key 5); (2) left and right on number key 4 and 6; (3) top and bottom on number key 8 and 2. A force-torque transducer underneath the keypad measured the fingertip force. An active-marker infrared motion analysis system measured the kinematics of the fingertip, hand, forearm, upper arm and torso. Joint moments for the metacarpophalangeal, wrist, elbow, and shoulder joints were estimated using inverse dynamics. Tapping in the top-bottom orientation introduced the largest biomechanical loading on the upper extremity especially for the proximal joint, followed by tapping in the left-right orientation, and the lowest loading was observed during single key switch tapping. Directional tapping on average increased the fingertip force, joint excursion, and peak-to-peak joint torque by 45%, 190% and 55%, respectively. Identifying the biomechanical loading patterns associated with these fundamental movements of keying improves the understanding of the risks of upper extremity musculoskeletal disorders for computer keyboard users. Copyright © 2010 Elsevier Ltd. All rights reserved.

  10. 38 CFR 4.71 - Measurement of ankylosis and joint motion.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ...) Shoulder rotation—arm abducted to 90°, elbow flexed to 90° with the position of the forearm reflecting the midpoint 0° between internal and external rotation of the shoulder; and (b) supination and pronation—the...

  11. 38 CFR 4.71 - Measurement of ankylosis and joint motion.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) Shoulder rotation—arm abducted to 90°, elbow flexed to 90° with the position of the forearm reflecting the midpoint 0° between internal and external rotation of the shoulder; and (b) supination and pronation—the...

  12. 38 CFR 4.71 - Measurement of ankylosis and joint motion.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) Shoulder rotation—arm abducted to 90°, elbow flexed to 90° with the position of the forearm reflecting the midpoint 0° between internal and external rotation of the shoulder; and (b) supination and pronation—the...

  13. 38 CFR 4.71 - Measurement of ankylosis and joint motion.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) Shoulder rotation—arm abducted to 90°, elbow flexed to 90° with the position of the forearm reflecting the midpoint 0° between internal and external rotation of the shoulder; and (b) supination and pronation—the...

  14. 38 CFR 4.71 - Measurement of ankylosis and joint motion.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) Shoulder rotation—arm abducted to 90°, elbow flexed to 90° with the position of the forearm reflecting the midpoint 0° between internal and external rotation of the shoulder; and (b) supination and pronation—the...

  15. The 1990-1991 project summaries

    NASA Technical Reports Server (NTRS)

    1991-01-01

    Georgia Tech's School of Textile & Fiber Engineering and School of Mechanical Engineering participated in four cooperative design efforts this year. One group designed a thermal shield for a lunar telescope. The second group designed a selenotextile habitat shielding structure. The third group designed a pneumatically assisted elbow joint for the NASA zero-prebreathe suit (ZPS). The final group designed an electromechanical system to power an astronaut's finger joints. Summaries of these projects are presented.

  16. The 1990-1991 project summaries

    NASA Astrophysics Data System (ADS)

    Georgia Tech's School of Textile & Fiber Engineering and School of Mechanical Engineering participated in four cooperative design efforts this year. One group designed a thermal shield for a lunar telescope. The second group designed a selenotextile habitat shielding structure. The third group designed a pneumatically assisted elbow joint for the NASA zero-prebreathe suit (ZPS). The final group designed an electromechanical system to power an astronaut's finger joints. Summaries of these projects are presented.

  17. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments.

    PubMed

    Pasternak, Braulio; Sousa Neto, Manoel Damião de; Dionísio, Valdeci Carlos; Pécora, Jesus Djalma; Silva, Ricardo Gariba

    2012-02-01

    This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques.

  18. Analysis of kinematic, kinetic and electromyographic patterns during root canal preparation with rotary and manual instruments

    PubMed Central

    PASTERNAK-JÚNIOR, Braulio; de SOUSA NETO, Manoel Damião; DIONÍSIO, Valdeci Carlos; PÉCORA, Jesus Djalma; SILVA, Ricardo Gariba

    2012-01-01

    Objective This study assessed the muscular activity during root canal preparation through kinematics, kinetics, and electromyography (EMG). Material and Methods The operators prepared one canal with RaCe rotary instruments and another with Flexo-files. The kinematics of the major joints was reconstructed using an optoelectronic system and electromyographic responses of the flexor carpi radialis, extensor carpi radialis, brachioradialis, biceps brachii, triceps brachii, middle deltoid, and upper trapezius were recorded. The joint torques of the shoulder, elbow and wrist were calculated using inverse dynamics. In the kinematic analysis, angular movements of the wrist and elbow were classified as low risk factors for work-related musculoskeletal disorders. With respect to the shoulder, the classification was medium-risk. Results There was no significant difference revealed by the kinetic reports. The EMG results showed that for the middle deltoid and upper trapezius the rotary instrumentation elicited higher values. The flexor carpi radialis and extensor carpi radialis, as well as the brachioradialis showed a higher value with the manual method. Conclusion The muscular recruitment for accomplishment of articular movements for root canal preparation with either the rotary or manual techniques is distinct. Nevertheless, the rotary instrument presented less difficulty in the generation of the joint torque in each articulation, thus, presenting a greater uniformity of joint torques. PMID:22437679

  19. “In vitro” Implantation Technique Based on 3D Printed Prosthetic Prototypes

    NASA Astrophysics Data System (ADS)

    Tarnita, D.; Boborelu, C.; Geonea, I.; Malciu, R.; Grigorie, L.; Tarnita, D. N.

    2018-06-01

    In this paper, Rapid Prototyping ZCorp 310 system, based on high-performance composite powder and on resin-high strength infiltration system and three-dimensional printing as a manufacturing method are used to obtain physical prototypes of orthopaedic implants and prototypes of complex functional prosthetic systems directly from the 3D CAD data. These prototypes are useful for in vitro experimental tests and measurements to optimize and obtain final physical prototypes. Using a new elbow prosthesis model prototype obtained by 3D printing, the surgical technique of implantation is established. Surgical implantation was performed on male corpse elbow joint.

  20. [Pulley for strengthening a muscle replacement operation across two joints in brachial plexus lesion: description of the surgical technique].

    PubMed

    Berger, A; Schaller, E; Becker, M H

    1994-01-01

    The reconstruction of lost muscle functions in cases of brachial plexus lesion is possible even in those cases where primary nerve reconstruction was not performed or unsuccessful. If there are only few motor nerves available, we prefer free latissimus dorsi transplantation or pedicled latissimus dorsi transposition for replacement of biceps and finger flexors. The combination of elbow flexion and finger flexion becomes possible when the transposed motor is passed around a suitable pulley in the elbow region like the flexor carpi ulnaris or carpi radialis.

  1. [External stability of the elbow after surgical treatment of epicondylitis. Presentation of a case].

    PubMed

    Llop-Corbacho, A; Romero-Ruiz, J; Denia-Alarcón, N

    2014-01-01

    Elbow instability is a difficult to diagnose condition in certain cases, and could lead to some problems that limit daily functioning, such as joint blocks, bumps, projections, muscle weakness, and persistent pain. A case is presented of a patient with a clinical picture of epicondylitis, with a previous history of a fall on the affected arm. As there was no improvement after performing conventional non-aggressive treatment, surgery was performed on the affected tendon. The outcome of this was persistent pain and clinical instability of the elbow that ended up requiring surgery to reconstruct the ligament over the external complex. In follow-up 6 months after the operation, the clinical instability had disappeared, but there was still external discomfort and a 30° extension deficit. When faced with a picture of epicondylitis with a previous injury that does not respond to conventional therapies, it is important to take into account the possibility of an underlying elbow instability, ruling this out with a correct physical examination and, where necessary, with the appropriate complementary tests. Copyright © 2013 SECOT. Published by Elsevier Espana. All rights reserved.

  2. Throwing velocity and kinematics in elite male water polo players.

    PubMed

    Melchiorri, G; Padua, E; Padulo, J; D'Ottavio, S; Campagna, S; Bonifazi, M

    2011-12-01

    Fifty-three members of the Italian Men Water Polo Team were filmed using two synchronized cameras, while they were shooting a goal. Considering the differences in body mass, height, training strategies and the technical-tactical features of the players, the aims of this study were to employ video-analysis techniques in order to investigate selected kinematic parameters in water polo throwing, and to provide comprehensive quantitative information on the throwing movement in relation to the different team player positions. Video analysis was used to estimate the elbow angle at release, the shoulder angle at follow through, the back and head height at ball release, trunk rotation angle and ball velocity at release. Ball release velocities ranged from 21.0 to 29.8 m/s (average value 25.3±1.4 m/s), for field players. Goal keepers show the lowest team values (average 21.7±0.3 m/s). Similar to previous study results, ball release was typically reached just prior to the elbow approaching full extension (151.6±3.6°), and the follow through shoulder angle was 143±5.9°. No significant statistical difference was recorded between injured and non-injured athletes. No positive association was demonstrated between physical characteristics (body mass and height) and ball velocity.

  3. Products resulting from cleavage of the interglobular domain of aggrecan in samples of synovial fluid collected from dogs with early- and late-stage osteoarthritis.

    PubMed

    Innes, John F; Little, Chris B; Hughes, Clare E; Caterson, Bruce

    2005-10-01

    To investigate interglobular domain (IGD) cleavage of aggrecan in dogs with naturally developing osteoarthritis (OA). Samples of synovial fluid (SF) obtained from 3 cubital (elbow) joints and 3 stifle joints of 4 clinically normal dogs, 24 elbow joints of 12 dogs with early-stage OA, 8 stifle joints of 5 dogs with early-stage OA, and 10 stifle joints of 9 dogs with late-stage OA. Fractions of SF were assayed for total glycosaminoglycan (GAG) content and also subjected to Western blot analysis by use of monoclonal antibodies against neoepitopes generated by cleavage of the IGD of the aggrecan protein core by matrix metalloproteinase (MMP; BC-14) and aggrecanase (BC-3). Total GAG content of SF from joints of clinically normal dogs did not differ from that of dogs with early-stage OA. The GAG content of SF from joints of dogs with late-stage OA was significantly lower, compared with GAG content for other SF samples. Aggrecanase-generated fragments were detected in SF from all groups but not in all samples. Matrix metalloproteinase-generated fragments were not detected in any SF samples. In early-stage OA, high-molecular-weight aggrecanase-generated aggrecan catabolites were evident. GAG content of SF obtained from dogs with late-stage OA is significantly decreased, suggesting proteoglycan depletion of cartilage. Aggrecanases, but not MMPs, are the major proteolytic enzymes responsible for IGD cleavage of aggrecan in canine joints. Analyses of SF samples to detect aggrecanase-generated catabolites may provide an early biomarker for discriminating early- and late-stage OA in dogs.

  4. Deficits in glenohumeral passive range of motion increase risk of elbow injury in professional baseball pitchers: a prospective study.

    PubMed

    Wilk, Kevin E; Macrina, Leonard C; Fleisig, Glenn S; Aune, Kyle T; Porterfield, Ron A; Harker, Paul; Evans, Timothy J; Andrews, James R

    2014-09-01

    Injuries to the elbow joint in baseball pitchers appear common. There appears to be a correlation between shoulder range of motion and elbow injuries. To prospectively determine whether decreased ROM of the throwing shoulder is correlated with the onset of elbow injuries in professional baseball pitchers. Cohort study; Level of evidence, 2. For 8 consecutive years (2005-2012), passive range of motion of both the throwing and nonthrowing shoulders of all major and minor league pitchers within a single professional baseball organization were measured by using a bubble goniometer during spring training. In total, 505 examinations were conducted on 296 pitchers. Glenohumeral external rotation and internal rotation were assessed in the supine position with the arm at 90° of abduction and in the plane of the scapula. The scapula was stabilized per methods previously established. Total rotation was defined as the sum of external rotation and internal rotation. Passive shoulder flexion was assessed with the subject supine and the scapula stabilized per methods previously established. Elbow injuries and days missed because of elbow injuries were assessed and recorded by the medical staff of the team. Throwing and nonthrowing shoulder measurements were compared by using Student t tests; 1-tailed Fisher exact tests were performed to identify significant associations between shoulder motion and elbow injury. Nominal logistic regression was performed to determine the odds of elbow injury. Significant differences were noted during side-to-side comparisons within subjects. There were 49 elbow injuries and 8 surgeries in 38 players, accounting for a total of 2551 days missed. Neither glenohumeral internal rotation deficit nor external rotation insufficiency was correlated with elbow injuries. Pitchers with deficits of >5° in total rotation in their throwing shoulders had a 2.6 times greater risk for injury. Pitchers with deficit of ≥5° in flexion of the throwing shoulder had a 2.8 times greater risk for injury. Bilateral differences in shoulder total rotation and flexion had a significant effect on the risk for elbow injuries in pitchers. Clinicians need to be aware of these findings and plan preventive programs that address these issues in hopes of reducing elbow injuries. © 2014 The Author(s).

  5. Cable compliance

    NASA Technical Reports Server (NTRS)

    Kerley, J.; Eklund, W.; Burkhardt, R.; Rossoni, P.

    1992-01-01

    The object of the investigation was to solve mechanical problems using cable-in-bending and cable-in-torsion. These problems included robotic contacts, targets, and controls using cable compliance. Studies continued in the use of cable compliance for the handicapped and the elderly. These included work stations, walkers, prosthetic knee joints, elbow joints, and wrist joints. More than half of these objects were met, and models were made and studies completed on most of the others. It was concluded that the many different and versatile solutions obtained only opened the door to many future challenges.

  6. EFFECT OF INTENSE FUNCTIONAL TASK TRAINING UPON TEMPORAL STRUCTURE OF VARIABILITY OF UPPER EXTREMITY POST STROKE

    PubMed Central

    Sethi, Amit; Davis, Sandra; McGuirk, Theresa; Patterson, Tara S.; Richards, Lorie G.

    2012-01-01

    Study Design Quasi-experimental design Introduction Although the effectiveness of constraint induced movement therapy (CIMT) in upper extremity (UE) rehabilitation post stroke is well known, the efficacy of CIMT to enhance the temporal structure of variability in upper extremity movement is not known. Purpose The purpose of this study was to investigate whether CIMT could enhance temporal structure of variability in upper extremity movement in individuals with chronic stroke. Methods Six participants with chronic stroke underwent CIMT for 4 hours/day for 2 weeks. Participants performed three trials of functional reach-to-grasp before and after CIMT. Temporal structure of variability was determined by calculating approximate entropy (ApEn) in shoulder, elbow and wrist flexion/extension joint angles. Results ApEn increased post CIMT, however, statistical significance was not achieved (p > 0.0167). Conclusion Future studies with larger sample size are warranted to investigate the effect of CIMT upon temporal structure of variability in UE movement. PMID:23084461

  7. The relationship between consistency of propulsive cycles and maximum angular velocity during wheelchair racing.

    PubMed

    Wang, Yong Tai; Vrongistinos, Konstantinos Dino; Xu, Dali

    2008-08-01

    The purposes of this study were to examine the consistency of wheelchair athletes' upper-limb kinematics in consecutive propulsive cycles and to investigate the relationship between the maximum angular velocities of the upper arm and forearm and the consistency of the upper-limb kinematical pattern. Eleven elite international wheelchair racers propelled their own chairs on a roller while performing maximum speeds during wheelchair propulsion. A Qualisys motion analysis system was used to film the wheelchair propulsive cycles. Six reflective markers placed on the right shoulder, elbow, wrist joints, metacarpal, wheel axis, and wheel were automatically digitized. The deviations in cycle time, upper-arm and forearm angles, and angular velocities among these propulsive cycles were analyzed. The results demonstrated that in the consecutive cycles of wheelchair propulsion the increased maximum angular velocity may lead to increased variability in the upper-limb angular kinematics. It is speculated that this increased variability may be important for the distribution of load on different upper-extremity muscles to avoid the fatigue during wheelchair racing.

  8. Modular multimorphic kinematic arm structure and pitch and yaw joint for same

    DOEpatents

    Martin, H. Lee; Williams, Daniel M.; Holt, W. Eugene

    1989-01-01

    A multimorphic kinematic manipulator arm is provided with seven degrees of freedom and modular kinematic redundancy through identical pitch/yaw, shoulder, elbow and wrist joints and a wrist roll device at the wrist joint, which further provides to the manipulator arm an obstacle avoidance capability. The modular pitch/yaw joints are traction drive devices which provide backlash free operation with smooth torque transmission and enhanced rigidity. A dual input drive arrangement is provided for each joint resulting in a reduction of the load required to be assumed by each drive and providing selective pitch and yaw motions by control of the relative rotational directions of the input drive.

  9. Modular multimorphic kinematic arm structure and pitch and yaw joint for same

    DOEpatents

    Martin, H.L.; Williams, D.M.; Holt, W.E.

    1987-04-21

    A multimorphic kinematic manipulator arm is provided with seven degrees of freedom and modular kinematic redundancy through identical pitch/yaw, shoulder, elbow and wrist joints and a wrist roll device at the wrist joint, which further provides to the manipulator arm an obstacle avoidance capability. The modular pitch/yaw joints are traction drive devices which provide backlash free operation with smooth torque transmission and enhanced rigidity. A dual input drive arrangement is provided for each joint resulting in a reduction of the load required to be assumed by each drive means and providing selective pitch and yaw motions by control of the relative rotational directions of the input drive means. 12 figs.

  10. Sonographic measurements of the ulnar nerve at the elbow with different degrees of elbow flexion.

    PubMed

    Patel, Prutha; Norbury, John W; Fang, Xiangming

    2014-05-01

    To determine whether there were differences in the cross-sectional area (CSA) and the flattening ratio of the normative ulnar nerve as it passes between the medial epicondyle and the olecranon at 30° of elbow flexion versus 90° of elbow flexion. Bilateral upper extremities of normal healthy adult volunteers were evaluated with ultrasound. The CSA and the flattening ratio of the ulnar nerve at the elbow as it passes between the medial epicondyle and the olecranon were measured, with the elbow flexed at 30° and at 90°, by 2 operators with varying ultrasound scanning experience by using ellipse and direct tracing methods. The results from the 2 different angles of elbow flexion were compared for each individual operator. Finally, intraclass correlations for absolute agreement and consistency between the 2 raters were calculated. An outpatient clinic room at a regional rehabilitation center. Twenty-five normal healthy adult volunteers. The mean CSA and the mean flattening ratio of the ulnar nerve at 30° of elbow flexion and at 90° of elbow flexion. First, for the ellipse method, the mean CSA of the ulnar nerve at 90° (9.93 mm(2)) was slightly larger than at 30° (9.77 mm(2)) for rater 1. However, for rater 2, the mean CSA of the ulnar nerve at 90° (6.80 mm(2)) was slightly smaller than at 30° (7.08 mm(2)). This was found to be statistically insignificant when using a matched pairs t test and the Wilcoxon signed-rank test, with a significance level of .05. Similarly, the difference between the right side and the left side was not statistically significant. The intraclass correlations for absolute agreement between the 2 raters were not very high due to different measurement locations, but the intraclass correlations for consistency were high. Second, for the direct tracing method, the mean CSA at 90° (7.26 mm(2)) was slightly lower than at 30° (7.48 mm(2)). This was found to be statistically nonsignificant when using the matched pairs t test and the Wilcoxon signed-rank test with a significance level of .05. There was no significant difference in the average flattening ratio between the 2 angles for the left arm (0.54 at 30° vs 0.56 at 90°; P = .619 for the matched pairs t test and .274 for the Wilcoxon signed-rank test). However, for the right arm, the flattening ratio at 90° was significantly higher than that at 30° (0.58 at 90° vs 0.50 at 30°; P = .007 for both the matched pairs t test and the Wilcoxon signed-rank test). The mean CSA of the ulnar nerve at the elbow at 30° was not significantly different than at 90°. However, the average flattening ratio at 90° was found to be significantly higher than at 30° for the right arm. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  11. PREFERED SURGICAL TECHNIQUE USED BY ORTHOPEDISTS IN ACUTE ACROMIOCLAVICULAR DISLOCATION

    PubMed Central

    NISHIMI, ALEXANDRE YUKIO; ARBEX, DEMETRIO SIMÃO; MARTINS, DIOGO LUCAS CAMPOS; GUSMÃO, CARLOS VINICIUS BUARQUE DE; BONGIOVANNI, ROBERTO RANGEL; PASCARELLI, LUCIANO

    2016-01-01

    ABSTRACT Objective: To determine whether training on shoulder and elbow surgery influences the orthopedist surgeons' preferred technique to address acute acromioclavicular joint dislocation (ACD). Methods: A survey was conducted with shoulder and elbow specialists and general orthopedists on their preferred technique to address acute ACD. Results: Thirty specialists and forty-five general orthopedists joined the study. Most specialists preferred the endobutton technique, while most general orthopedists preferred the modified Phemister procedure for coracoclavicular ligament repair using anchors. We found no difference between specialists and general orthopedists in the number of tunnels used to repair the coracoclavicular ligament; preferred method for wire insertion through the clavicular tunnels; buried versus unburied Kirschner wire insertion for acromioclavicular temporary fixation; and time for its removal; and regarding the suture thread used for deltotrapezoidal fascia closure. Conclusion: Training on shoulder and elbow surgery influences the surgeons' preferred technique to address acute ACD. Level of Evidence V, Expert Opinion. PMID:28149190

  12. On the Efficacy of Isolating Shoulder and Elbow Movements with a Soft, Portable, and Wearable Robotic Device

    NASA Technical Reports Server (NTRS)

    Kadivar, Zahra; Beck, Christopher E.; Rovekamp, Roger N.; O'Malley, Marcia K.; Joyce, Charles A.

    2016-01-01

    Treatment intensity has a profound effect on motor recovery following neurological injury. The use of robotics has potential to automate these labor-intensive therapy procedures that are typically performed by physical therapists. Further, the use of wearable robotics offers an aspect of portability that may allow for rehabilitation outside the clinic. The authors have developed a soft, portable, lightweight upper extremity wearable robotic device to provide motor rehabilitation of patients with affected upper limbs due to traumatic brain injury (TBI). A key feature of the device demonstrated in this paper is the isolation of shoulder and elbow movements necessary for effective rehabilitation interventions. Herein is presented a feasibility study with one subject and demonstration of the device's ability to provide safe, comfortable, and controlled upper extremity movements. Moreover, it is shown that by decoupling shoulder and elbow motions, desired isolated joint actuation can be achieved.

  13. Long-term functional results and isokinetic strength evaluation after arthroscopic tenotomy of the long head of biceps tendon

    PubMed Central

    The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T.; Halliday, Michael J. C.; Ackland, Timothy R.

    2014-01-01

    Introduction: The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Materials and Methods: Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Results: Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI −1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Discussion: Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Level of Evidence IV: Case series without comparison group. PMID:25258498

  14. Long-term functional results and isokinetic strength evaluation after arthroscopic tenotomy of the long head of biceps tendon.

    PubMed

    The, Bertram; Brutty, Mike; Wang, Allan; Campbell, Peter T; Halliday, Michael J C; Ackland, Timothy R

    2014-07-01

    The objective of this study is to evaluate the biomechanical function of the upper arm after arthroscopic long head of biceps (LHB) tenotomy at long-term follow-up. Twenty-five male subjects ranging from 30 to 63 years old were evaluated at a mean follow-up of 7.0 years after tenotomy. Bilateral isokinetic testing was performed to obtain peak torque values, as well as total work done throughout the full range of elbow flexion and supination. Magnetic resonance imaging scans revealed nine unrecognized LHB ruptures in the contralateral arm, leaving 16 subjects to complete the testing protocol. The mean quickDASH score was 8.1 (standard error [SE] 2.5). The mean oxford elbow score was 97.9 (SE 1.6). The tenotomy arm recorded a decrease in peak flexion torque of 7.0% (confidence interval [CI] 1.2-12.8), and a decrease in the peak supination torque of 9.1% (CI 1.8-16.4) relative to the contralateral arm. The total work carried out through the full range of joint motion was reduced in elbow flexion by 5.1% (CI -1.3-11.4) and in forearm supination by 5.7% (CI-2.4-13.9). Maximum strength in elbow flexion and forearm supination is significantly reduced compared with the contralateral arm. However, this impairment is partially compensated for by relatively greater strength sustained through the latter stages of joint motion. This results in comparable total work measurements between the tenotomised and contralateral side, potentially accounting for ongoing high levels of patient satisfaction and clinical function in the long term after LHB tenotomy. Case series without comparison group.

  15. Reactive oligoarthritis in a patient with Clostridium difficile pseudomembranous colitis. Review of the literature.

    PubMed

    Veillard, E; Guggenbuhl, P; Bello, S; Lamer, F; Chalès, G

    1998-12-01

    A 57-year-old man developed oligoarthritis of the right sacroiliac joint, knee and elbow in the wake of Clostridium difficile pseudomembranous colitis. He was HLA B27-positive and had a history of Reiter's syndrome. His joint manifestations resolved after a course of nonsteroidal antiinflammatory drug therapy and injection of the right knee with triamcinolone acetonide. Clostridium difficile should be recognized as a rare cause of reactive arthritis.

  16. Intrarater reliability of goniometry and hand-held dynamometry for shoulder and elbow examinations in female team handball athletes and asymptomatic volunteers.

    PubMed

    Fieseler, Georg; Molitor, Thomas; Irlenbusch, Lars; Delank, Karl-Stefan; Laudner, Kevin G; Hermassi, Souhail; Schwesig, Rene

    2015-12-01

    To evaluate the intrarater reliability for examining active range of motion (ROM) and isometric strength of the shoulder and elbow among asymptomatic female team handball athletes and a control group using a manual goniometer and hand-held dynamometry (HHD). 22 female team handball athletes (age: 21.0 ± 3.7 years) and 25 volunteers (13 female, 12 male, age: 21.9 ± 1.24 years) participated to determine bilateral ROM for shoulder rotation and elbow flexion/extension, as well as isometric shoulder rotation and elbow flexion/extension strength. Subjects were assessed on two separate test sessions with 7 days between sessions. Relative (intraclass correlation coefficients (ICC) and standard error of measurement (SEM) reliability were calculated. Reliability for ROM and strength were good to excellent for both shoulders and groups (athletes: ICC = 0.94-0.97, SEM 1.07°-4.76 N, controls: ICC = 0.96-1.00, SEM = 0.00 N-4.48 N). Elbow measurements for both groups also showed good-to-excellent reliability (athletes: ICC = 0.79-0.97, SEM = 0.98°-5.94 N, controls: ICC = 0.87-1.00, SEM = 0.00 N-5.43 N). It is important to be able to reliably reproduce active ROM and isometric strength evaluations. Using a standardized testing position, goniometry and HHD are reliable instruments in the assessment of shoulder and elbow joint performance testing. We showed good-to-excellent reproducible results for male and female control subjects and female handball athletes, although the single parameters in ROM and strength were different for each group and between the shoulders and elbows.

  17. Determining Exercise Strength Requirements for Astronaut Critical Mission Tasks: Reaching Under G-Load

    NASA Technical Reports Server (NTRS)

    Schaffner, Grant; Bentley, Jason

    2008-01-01

    The critical mission tasks assessments effort seeks to determine the physical performance requirements that astronauts must meet in order to safely and successfully accomplish lunar exploration missions. These assessments will determine astronaut preflight strength, fitness, and flexibility requirements, and the extent to which exercise and other countermeasures must prevent the physical deconditioning associated with prolonged weightlessness. The purpose is to determine the flexibility and strength that crewmembers must possess in order to reach Crew Exploration Vehicle controls during maneuvers that result in sustained acceleration levels ranging from 3.7G to 7.8G. An industry standard multibody dynamics application was used to create human models representing a 5th percentile female, a 50th percentile male, and a 95th percentile male. The additional mass of a space suit sleeve was added to the reaching arm to account for the influence of the suit mass on the reaching effort. The human model was merged with computer models of a pilot seat and control panel for the Crew Exploration Vehicle. Three dimensional paths were created that guided the human models hand from a starting position alongside its thigh to three control targets: a joystick, a keyboard, and an overhead switch panel. The reaching motion to each target was repeated under four vehicle acceleration conditions: nominal ascent (3.7G), two ascent aborts (5.5G and 7.8G) and lunar reentry (4.6G). Elbow and shoulder joint angular excursions were analyzed to assess range of motion requirements. Mean and peak elbow and shoulder joint torques were determined and converted to equivalent resistive exercise loads to assess strength requirements. Angular excursions for the 50th and 95th percentile male models remained within joint range of motion limits. For the 5th percentile female, both the elbow and the shoulder exceeded range of motion limits during the overhead reach. Elbow joint torques ranged from 10 N-m (nominal ascent) to 60 N-m (ascent abort). Shoulder joint torques ranged from 65 N-m (nominal ascent) to 280 N-m (ascent abort). Maximal equivalent exercise loads reached 30 lb in tricep extension, 9 lb in bicep curl, 110 lb in unilateral pullover and unilateral bench press for nominal conditions (lunar reentry), and 188 lb in unilateral pullover and unilateral bench press. The location of the pilot seat was found to be inadequately located to allow a 5th percentile female to reach the switches on the overhead panel. Elbow strength requirements were found to be well within population norms. Shoulder strength was found to be a limiting factor. Reaching under nominal ascent and lunar reentry conditions was found to require near maximal shoulder strength. Reaching under ascent abort conditions requires shoulder strength well beyond population norms. Pilot seats must adjust to accomodate a 5th percentile female. Exercise countermeasures must maintain maximal pullover and bench press strength to allow pilots to reach and operate controls during lunar reentry. Reaching will not be possible during ascent abort conditions. Flight controls should be built into armrests or flight control must be accomplished by autonomous systems during acceleration exceeding 4.6G.

  18. The different role of each head of the triceps brachii muscle in elbow extension.

    PubMed

    Kholinne, Erica; Zulkarnain, Rizki Fajar; Sun, Yu Cheng; Lim, SungJoon; Chun, Jae-Myeung; Jeon, In-Ho

    2018-03-01

    The aim of this study was to investigate the functional role of each head of the triceps brachii muscle, depending on the angle of shoulder elevation, and to compare each muscle force and activity by using a virtual biomechanical simulator and surface electromyography. Ten healthy participants (8 males and 2 females) were included in this study. The mean age was 29.2 years (23-45). Each participant performed elbow extension tasks in five different degrees (0, 45, 90, 135, and 180°) of shoulder elevation with three repetitions. Kinematics data and surface electromyography signal of each head of the triceps brachii were recorded. Recorded kinematics data were then applied to an inverse kinematics musculoskeletal modeling software function (OpenSim) to analyze the triceps brachii's muscle force. Correlation between muscle force, muscle activity, elbow extension, and shoulder elevation angle were compared and analyzed for each head of triceps brachii. At 0° shoulder elevation, the long head of the triceps brachii generates a significantly higher muscle force and muscle activation than the lateral and medial heads (p < 0.05). While at 90°, 135° and 180° shoulder elevation, the medial head of the triceps brachii showed a significantly higher muscle force than the long and the lateral heads (p < 0.05). Each head of the triceps brachii has a different pattern of force and activity during different shoulder elevations. The long head contributes to elbow extension more at shoulder elevation and the medial head takes over at 90° and above of shoulder elevation. This study provides further understanding of triceps brachii's for clinicians and health trainers who need to investigate the functional role of the triceps brachii in detail. Copyright © 2018. Production and hosting by Elsevier B.V.

  19. Pattern of improvement in upper limb pointing task kinematics after a 3-month training program with robotic assistance in stroke.

    PubMed

    Pila, Ophélie; Duret, Christophe; Laborne, François-Xavier; Gracies, Jean-Michel; Bayle, Nicolas; Hutin, Emilie

    2017-10-13

    When exploring changes in upper limb kinematics and motor impairment associated with motor recovery in subacute post stroke during intensive therapies involving robot-assisted training, it is not known whether trained joints improve before non-trained joints and whether target reaching capacity improves before movement accuracy. Twenty-two subacute stroke patients (mean delay post-stroke at program onset 63 ± 29 days, M2) underwent 50 ± 17 (mean ± SD) 45-min sessions of robot-assisted (InMotion™) shoulder/elbow training over 3 months, in addition to conventional occupational therapy. Monthly evaluations (M2 to M5) included Fugl-Meyer Assessment (FM), with subscores per joint, and four robot-based kinematic measures: mean target distance covered, mean velocity, direction accuracy (inverse of root mean square error from straight line) and movement smoothness (inverse of mean number of zero-crossings in the velocity profile). We assessed delays to reach statistically significant improvement for each outcome measure. At M5, all clinical and kinematic parameters had markedly improved: Fugl-Meyer, +65% (median); distance covered, +87%; mean velocity, +101%; accuracy, +134%; and smoothness, +96%. Delays to reach statistical significance were M3 for the shoulder/elbow Fugl-Meyer subscore (+43%), M4 for the hand (+80%) and M5 for the wrist (+133%) subscores. For kinematic parameters, delays to significant improvements were M3 for distance (+68%), velocity (+65%) and smoothness (+50%), and M5 for accuracy (+134%). An intensive rehabilitation program combining robot-assisted shoulder/elbow training and conventional occupational therapy was associated with improvement in shoulder and elbow movements first, which suggests focal behavior-related brain plasticity. Findings also suggested that recovery of movement quantity related parameters (range of motion, velocity and smoothness) might precede that of movement quality (accuracy). EudraCT 2016-005121-36 . Date of Registration: 2016-12-20. Date of enrolment of the first participant to the trial: 2009-11-24 (retrospective data).

  20. [A case control study of perpendicular or parallel double plate for the treatment of young and middle-aged patients with type C fractures of distal humerus].

    PubMed

    Yu, Ye-Feng; Dai, Jia-Ping; Sheng, Jian-Ming; Zhou, Xiao

    2017-06-25

    To compare clinical outcomes of perpendicular or parallel double plate in treating type C fractures of distal humerus in adults. From March 2009 and March 2013, 40 adult patients with type C distal humerus fractures were treated. The patients were divided into two groups according to fixed form. In perpendicular group(group A), there were 13 males and 9 females with a mean age of (37.56±9.24) years old(ranged 18 to 56);while in parallel plating group(group B), including 11 males and 7 females, with a mean age of (41.35±9.03) year old(ranged 20 to 53). All fractures were fresh and closed without blood vessels or nerve damaged. Incision length, operating time, blood loss, hospital stay, preoperative and postoperative radiological change, range of activity of elbow joint, Mayo score, flexor and extensor elbow strength, and postoperative complications were observed and compared. All incisions were healed well. One patient occurred myositis ossificans between two groups. Two patients in group A and 1 patient in group B occurred elbow joint stiffness. All fractures were obtained bone union. Group A were followed up from 20 to 36 months with an average of (25.2±7.1) months, while group B were followed up from 18 to 35 months with an average of(24.3±6.0) months. There were significant differences in blood loss and operative time, while there was no obvious meaning in incision length, hospital stay, muscle strength, fracture healing time, range of activity of elbow joint. Mayo score of group A was 82.27±10.43, 6 cases obtained excellent results, 12 good, 3 moderate and 1 poor;in group B was 81.94±12.02, 5 cases obtained excellent results, 9 good, 3 moderate and 1 poor;and there were no statistical significance between two groups. There was no significant differences in clinical effects between perpendicular and parallel double plate for adult patients with type C distal humerus fractures, while the operation should choose according to facture and proficiency of operator.

  1. Design and demonstration of an acoustic right-angle bend.

    PubMed

    Lu, Wenjia; Jia, Han; Bi, Yafeng; Yang, Yuzhen; Yang, Jun

    2017-07-01

    In this paper, a broadband acoustic right-angle bend device in air is designed, fabricated and experimentally characterized. Perforated panels with various hole-sizes are used to construct the bend structure. Both the simulated and experimental results verify that the acoustic beam can be rotated effectively through the acoustic bend in a wide frequency range. This model may have potential applications in some areas such as sound absorption and acoustic detection in elbow pipes.

  2. [Imaging in rheumatoid arthritis of the elbow].

    PubMed

    Lerch, K; Herold, T; Borisch, N; Grifka, J

    2003-08-01

    Early specific radiologic changes of rheumatoid arthritis can usually be detected in the hands and feet. Later stages of the disease process show a typical centripetal spread of the affected joints, i.e., shoulder, elbow, and knee. For prognostic assessment of cubital rheumatoid arthritis, conventional radiography still remains the gold standard. X-rays allow objective scoring and thus classification into standardized stages. A concentric destruction of the rheumatic joint as compared to deformity in the degenerative joint is the typical radiologic symptom to look for. For soft tissue assessment, ultrasound (US) should be the diagnostic tool of choice. Due to the thin surrounding soft tissue layer, as well as the advanced high-resolution technology, bony structures can also be well demonstrated in any plane. In the early arthritic stages, particularly the small changes, e.g., minimal erosions of the cortical area, are very well detectable by US. The use of "color" allows good evaluation of the synovial inflammatory status. Modern imaging methods such as computer- assisted tomography (CAT) scan and magnetic resonance imaging (MRI) are restricted to a few set indications and should not be chosen for routine examination. More invasive methods such as arthrography are no longer indicated for assessment of cubital rheumatoid arthritis.

  3. Surgical treatment of acute type V acromioclavicular joint dislocations in professional athletes: an anatomic ligament reconstruction with synthetic implant augmentation.

    PubMed

    Triantafyllopoulos, Ioannis K; Lampropoulou-Adamidou, Kalliopi; Schizas, Nikitas P; Karadimas, Eleftherios V

    2017-12-01

    Most acromioclavicular (AC) joint injuries occur in men in their third decade of life during high-speed or high-impact body contact sports. The management of acute complete AC joint dislocation is surgical. Current surgical techniques include anatomic reconstruction of the main restraints of the AC joint and aim to improve functional outcomes and to reduce the complication rate. We present 10 cases of acute type V AC joint dislocation in professional athletes treated surgically with anatomic reconstruction of the coracoclavicular and AC ligaments and augmentation with the use of a synthetic polyester tape. The minimum follow-up of the patients was 2 years (mean, 48 months; range, 24-86 months). The postoperative functional outcome was assessed at 1 year and 2 years using the Constant-Murley, American Shoulder and Elbow Surgeons, and modified University of California-Los Angeles scoring systems. In all cases, the postoperative scores were significantly improved (P < .005 in all comparisons with the preoperative scores), and all patients returned to their preinjury high level of activity 6 months postoperatively. Radiographs at 1 month and 6 months revealed the maintenance of reduction. There were no complications. According to the results of our series of patients, demanding cases of acute AC joint dislocation Rockwood type V, in professional athletes, require anatomic fixation of both coracoclavicular and AC ligaments for return to sports as soon as possible and at the preinjury level of performance. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  4. Quantifying anti-gravity torques for the design of a powered exoskeleton.

    PubMed

    Ragonesi, Daniel; Agrawal, Sunil K; Sample, Whitney; Rahman, Tariq

    2013-03-01

    Designing an upper extremity exoskeleton for people with arm weakness requires knowledge of the joint torques due to gravity and joint stiffness, as well as, active residual force capabilities of users. The objective of this research paper is to describe the characteristics of the upper limb of children with upper limb impairment. This paper describes the experimental measurements of the torque on the upper limb due to gravity and joint stiffness of three groups of subjects: able-bodied adults, able-bodied children, and children with neuromuscular disabilities. The experiment involves moving the arm to various positions in the sagittal plane and measuring the resultant force at the forearm. This force is then converted to torques at the elbow and shoulder. These data are compared to a two-link lumped mass model based on anthropomorphic data. Results show that the torques based on anthropometry deviate from experimentally measured torques as the arm goes through the range. Subjects with disabilities also maximally pushed and pulled against the force sensor to measure maximum strength as a function of arm orientation. For all subjects, the maximum voluntary applied torque at the shoulder and elbow in the sagittal plane was found to be lower than gravity torques throughout the disabled subjects' range of motion. This experiment informs designers of upper limb orthoses on the contribution of passive human joint torques due to gravity and joint stiffness and the strength capability of targeted users.

  5. The effects of adding single-joint exercises to a multi-joint exercise resistance training program on upper body muscle strength and size in trained men.

    PubMed

    de França, Henrique Silvestre; Branco, Paulo Alexandre Nordeste; Guedes Junior, Dilmar Pinto; Gentil, Paulo; Steele, James; Teixeira, Cauê Vazquez La Scala

    2015-08-01

    The aim of this study was compare changes in upper body muscle strength and size in trained men performing resistance training (RT) programs involving multi-joint plus single-joint (MJ+SJ) or only multi-joint (MJ) exercises. Twenty young men with at least 2 years of experience in RT were randomized in 2 groups: MJ+SJ (n = 10; age, 27.7 ± 6.6 years) and MJ (n = 10; age, 29.4 ± 4.6 years). Both groups trained for 8 weeks following a linear periodization model. Measures of elbow flexors and extensors 1-repetition maximum (1RM), flexed arm circumference (FAC), and arm muscle circumference (AMC) were taken pre- and post-training period. Both groups significantly increased 1RM for elbow flexion (4.99% and 6.42% for MJ and MJ+SJ, respectively), extension (10.60% vs 9.79%, for MJ and MJ+SJ, respectively), FAC (1.72% vs 1.45%, for MJ and MJ+SJ, respectively), and AMC (1.33% vs 3.17% for MJ and MJ+SJ, respectively). Comparison between groups revealed no significant difference in any variable. In conclusion, 8 weeks of RT involving MJ or MJ+SJ resulted in similar alterations in muscle strength and size in trained participants. Therefore, the addition of SJ exercises to a RT program involving MJ exercises does not seem to promote additional benefits to trained men, suggesting MJ-only RT to be a time-efficient approach.

  6. Estimation of muscle response using three-dimensional musculoskeletal models before impact situation: a simulation study.

    PubMed

    Bae, Tae Soo; Loan, Peter; Choi, Kuiwon; Hong, Daehie; Mun, Mu Seong

    2010-12-01

    When car crash experiments are performed using cadavers or dummies, the active muscles' reaction on crash situations cannot be observed. The aim of this study is to estimate muscles' response of the major muscle groups using three-dimensional musculoskeletal model by dynamic simulations of low-speed sled-impact. The three-dimensional musculoskeletal models of eight subjects were developed, including 241 degrees of freedom and 86 muscles. The muscle parameters considering limb lengths and the force-generating properties of the muscles were redefined by optimization to fit for each subject. Kinematic data and external forces measured by motion tracking system and dynamometer were then input as boundary conditions. Through a least-squares optimization algorithm, active muscles' responses were calculated during inverse dynamic analysis tracking the motion of each subject. Electromyography for major muscles at elbow, knee, and ankle joints was measured to validate each model. For low-speed sled-impact crash, experiment and simulation with optimized and unoptimized muscle parameters were performed at 9.4 m/h and 10 m/h and muscle activities were compared among them. The muscle activities with optimized parameters were closer to experimental measurements than the results without optimization. In addition, the extensor muscle activities at knee, ankle, and elbow joint were found considerably at impact time, unlike previous studies using cadaver or dummies. This study demonstrated the need to optimize the muscle parameters to predict impact situation correctly in computational studies using musculoskeletal models. And to improve accuracy of analysis for car crash injury using humanlike dummies, muscle reflex function, major extensor muscles' response at elbow, knee, and ankle joints, should be considered.

  7. An assessment of the deflecting effect on human movement due to the Coriolis inertial forces in a space vehicle.

    PubMed

    Hennion, P Y; Mollard, R

    1993-01-01

    Under conditions of prolonged space flight, it may be feasible to restore gravity artificially using centrifugal inertial forces in a spinning vehicle. As a result, the motion of the passengers relative to the vehicle is affected by Coriolis forces. The aim of this study is to propose a theoretical method to evaluate the extent of these effects compared to other inertial or motor forces affecting movement. We investigated typical right upper limb movement in a numerical model with a two-solid-links mechanism, including a spherical joint for the shoulder and a hinge joint for the elbow. The inertial and dimensional characteristics of this model derive from measurements and computations obtained on laboratory subjects. The same is true for the movements assigned to the model. These were inferred from actual recordings of arm movement when the subject presses a button placed in front of him with his index finger. From these relative velocities, the resulting forces and moments applied to the elbow and the shoulder were computed for a 1 rad s-1 rotational speed of transport motion, using classical kinetic relations. The result is that the Coriolis moments are of the same order of magnitude as the corresponding inertial moments and one-tenth of the value of a typical elbow flexion moment. Thus, they should cause a significant disturbance in movement.

  8. Velocity associated characteristics of force production in college weight lifters

    PubMed Central

    Kanehisa, H.; Fukunaga, T.

    1999-01-01

    OBJECTIVE: To determine velocity specific isokinetic forces and cross sectional areas of reciprocal muscle groups in Olympic weight lifters. METHODS: The cross sectional area of the flexor or extensor muscles of the elbow or knee joint was determined by a B-mode ultrasonic apparatus in 34 college weight lifters and 31 untrained male subjects matched for age. Maximum voluntary force produced in the flexion and extension of the elbow and knee joints was measured on an isokinetic dynamometer at 60, 180, and 300 degrees/s. RESULTS: The average cross sectional area was 31-65% higher, and the force was 19-62% higher in weight lifters than in the untrained subjects. The ratio of force to cross sectional area was the same in both groups. The weight lifters showed a lower velocity associated decline in force than untrained subjects in the elbow and knee flexors but not in the extensors. CONCLUSIONS: These results indicate that for muscle contractions with velocities between 60 degrees/s and 300 degrees/s the difference in isokinetic force between weight lifters and untrained subjects can be primarily attributed to the difference in the muscle cross sectional area. However, the lower velocity associated decline in force implies that weight lifters may have a higher force per cross sectional area than untrained subjects at velocities above 300 degrees/s. 




 PMID:10205693

  9. Radiographic evaluation of perching-joint angles in cockatiels (Nymphicus hollandicus), Hispaniolan Amazon parrots (Amazona ventralis), and barred owls (Strix varia).

    PubMed

    Bonin, Glen; Lauer, Susanne K; Guzman, David Sanchez-Migallon; Nevarez, Javier; Tully, Thomas N; Hosgood, Giselle; Gaschen, Lorrie

    2009-06-01

    Information on perching-joint angles in birds is limited. Joint immobilization in a physiologic perching angle has the potential to result more often in complete restoration of limb function. We evaluated perching-joint angles in 10 healthy cockatiels (Nymphicus hollandicus), 10 Hispaniolan Amazons (Amazona ventralis), and 9 barred owls (Strix varia) and determined intra- and interobserver variability for goniometric measurements in 2 different radiographic projections. Intra- and interobserver variation was less than 7% for all stifle and intertarsal joint measurements but frequently exceeded 10% for the hip-joint measurements. Hip, stifle, and intertarsal perching angles differed significantly among cockatiels, Hispaniolan Amazon parrots, and barred owls. The accuracy of measurements performed on straight lateral radiographic projections with superimposed limbs was not consistently superior to measurements on oblique projections with a slightly rotated pelvis. Stifle and intertarsal joint angles can be measured on radiographs by different observers with acceptable variability, but intra- and interobserver variability for hip-joint-angle measurements is higher.

  10. Optimal management of ulnar collateral ligament injury in baseball pitchers

    PubMed Central

    Hibberd, Elizabeth E; Brown, J Rodney; Hoffer, Joseph T

    2015-01-01

    The ulnar collateral ligament stabilizes the elbow joint from valgus stress associated with the throwing motion. During baseball pitching, this ligament is subjected to tremendous stress and injury if the force on the ulnar collateral ligament during pitching exceeds the physiological limits of the ligament. Injuries to the throwing elbow in baseball pitchers result in significant time loss and typically surgical intervention. The purpose of this paper is to provide a review of current information to sports medicine clinicians on injury epidemiology, injury mechanics, injury risk factors, injury prevention, surgical interventions, nonsurgical interventions, rehabilitation, and return to play outcomes in baseball pitchers of all levels. PMID:26635490

  11. Differences in humeral retroversion in dominant and nondominant sides of young baseball players.

    PubMed

    Kurokawa, Daisuke; Yamamoto, Nobuyuki; Ishikawa, Hiroaki; Nagamoto, Hideaki; Takahashi, Hiroyuki; Muraki, Takayuki; Tanaka, Minoru; Sato, Katsumi; Itoi, Eiji

    2017-06-01

    The relationship between the disabled throwing shoulder and humeral retroversion has recently attracted a great deal of attention. However, none of the previous studies clarified when the side-to-side difference of humeral retroversion in young baseball players would start. This study aimed to clarify when the difference of humeral retroversion in the dominant and nondominant sides appeared in baseball players. The bicipital-forearm angle in bilateral shoulders of 172 elementary school baseball players was measured by ultrasound. The bicipital-forearm angle was defined as an angle between the perpendicular line to the bicipital groove and the ulnar long axis with the elbow flexed at 90°. The correlation between the bicipital-forearm angle and the grade and the difference of the bicipital-forearm angle between the dominant and nondominant sides were analyzed. In the nondominant shoulders, the bicipital-forearm angle increased with the grade in school (r = 0.32, P < .0001), but this was not observed in the dominant shoulders. In the fourth to sixth graders, the bicipital-forearm angles were significantly smaller in the dominant shoulders than in the nondominant shoulders. Our findings indicated that humeral retroversion decreased with age in the nonthrowing side but not in the throwing side and that the side-to-side difference of humeral retroversion in the baseball players became obvious from the fourth grade. We assume that the repetitive throwing motion restricts the physiologic humeral derotation process and the difference became apparent from the fourth grade when the growth spurt begins in boys. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  12. Point-of-Care Ultrasound: Sonographic Posterior Fat Pad Sign: A Case Report and Brief Literature Review.

    PubMed

    Okumura, Yoshito; Maldonado, Nestor; Lennon, Kyle; McCarty, Bryan; Underwood, Philipp; Nelson, Mathew

    2017-07-01

    Diagnosis of elbow fracture can sometimes be difficult with plain radiography due to overlapping bones, growth plates, and maturing bones in the pediatric population. The radiographic posterior fat pad (PFP) sign is one of the frequently referenced indirect signs of an occult elbow fracture. This sign can be falsely negative if the sign is subtle, and can be falsely positive when the position of the elbow is not flexed at 90 degrees. We discuss a case in which sonographic PFP sign helped to diagnose an elbow fracture. A 57-year-old female presented to the emergency department (ED) after a fall on an outstretched hand. The point-of-care ultrasound (POCUS) was completed identifying an elevated PFP and an anechoic joint fluid collection with innumerous floating hyperechogenic spicules visualized in the olecranon fossa. Diagnosis of a radial head fracture was later confirmed by plain radiograph. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: The increase in use and availability of POCUS in the ED makes this a very practical application. Our ability to rapidly perform the ultrasound of the elbow may allow us a more rapid diagnosis of pathology, as well as provide a way to further triage our patients. With time, it may even allow us to avoid routine use of plain radiography. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Features selection and classification to estimate elbow movements

    NASA Astrophysics Data System (ADS)

    Rubiano, A.; Ramírez, J. L.; El Korso, M. N.; Jouandeau, N.; Gallimard, L.; Polit, O.

    2015-11-01

    In this paper, we propose a novel method to estimate the elbow motion, through the features extracted from electromyography (EMG) signals. The features values are normalized and then compared to identify potential relationships between the EMG signal and the kinematic information as angle and angular velocity. We propose and implement a method to select the best set of features, maximizing the distance between the features that correspond to flexion and extension movements. Finally, we test the selected features as inputs to a non-linear support vector machine in the presence of non-idealistic conditions, obtaining an accuracy of 99.79% in the motion estimation results.

  14. Physical therapist screening and differential diagnosis for traumatic-onset elbow pain: A case report.

    PubMed

    VanWye, William R; Hoover, Donald L; Willgruber, Sean

    2016-10-01

    Elbow pain can originate from many sources yet have similar signs and symptoms, thereby presenting differential diagnostic challenges. The elbow is commonly injured, thus requiring all clinicians to possess excellent diagnostic skills. A 24-year-old woman slipped and fell on her outstretched left hand, experiencing immediate elbow pain. The same day radiographs were deemed negative by her orthopedist, who referred her to physical therapy with the diagnoses of elbow sprain and contusion. Immediately after examining the patient, the physical therapist consulted with the referring orthopedist. The decision to consult was based on: the mechanism of injury, pain severity out of proportion to the referred diagnoses, significantly limited ROM, abnormal joint end feels, exquisite pain with tactile and tuning fork bony palpation, and positive elbow extension test. The treating physical therapist shared the above-noted findings with the orthopedist, who overruled and recommended continuing the original prescription of non-steroidal anti-inflammatory medication and physical therapist treatment for four weeks. The physical therapist's updated plan of care at four weeks noted the patient's continued reports of pain, functional limitations, and disability. A magnetic resonance image (MRI) was then ordered, revealing a radial head fracture. A thorough history and examination by the physical therapist led to clustering of signs and symptoms, allowing for the development of a differential diagnosis list which included occult radial head fracture. All clinicians should be prepared to screen for complex conditions. Timely diagnosis and improved outcomes for clinically complex patients are increasingly necessary in contemporary healthcare reimbursement models.

  15. Predicting tibiotalar and subtalar joint angles from skin-marker data with dual-fluoroscopy as a reference standard.

    PubMed

    Nichols, Jennifer A; Roach, Koren E; Fiorentino, Niccolo M; Anderson, Andrew E

    2016-09-01

    Evidence suggests that the tibiotalar and subtalar joints provide near six degree-of-freedom (DOF) motion. Yet, kinematic models frequently assume one DOF at each of these joints. In this study, we quantified the accuracy of kinematic models to predict joint angles at the tibiotalar and subtalar joints from skin-marker data. Models included 1 or 3 DOF at each joint. Ten asymptomatic subjects, screened for deformities, performed 1.0m/s treadmill walking and a balanced, single-leg heel-rise. Tibiotalar and subtalar joint angles calculated by inverse kinematics for the 1 and 3 DOF models were compared to those measured directly in vivo using dual-fluoroscopy. Results demonstrated that, for each activity, the average error in tibiotalar joint angles predicted by the 1 DOF model were significantly smaller than those predicted by the 3 DOF model for inversion/eversion and internal/external rotation. In contrast, neither model consistently demonstrated smaller errors when predicting subtalar joint angles. Additionally, neither model could accurately predict discrete angles for the tibiotalar and subtalar joints on a per-subject basis. Differences between model predictions and dual-fluoroscopy measurements were highly variable across subjects, with joint angle errors in at least one rotation direction surpassing 10° for 9 out of 10 subjects. Our results suggest that both the 1 and 3 DOF models can predict trends in tibiotalar joint angles on a limited basis. However, as currently implemented, neither model can predict discrete tibiotalar or subtalar joint angles for individual subjects. Inclusion of subject-specific attributes may improve the accuracy of these models. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Studies on the influence of axial bends on ultrasonic guided waves in hollow cylinders (pipes)

    NASA Astrophysics Data System (ADS)

    Verma, Bhupesh; Balasubramaniam, Krishnan; Rajagopal, Prabhu

    2013-01-01

    Ultrasonic guided waves in hollow cylinders (pipes) are today widely applied as rapid screening tools in the inspection of straight pipe segments in oil, power generation and petrochemical processing industries. However, the characteristics of guided wave propagation across features such as bends in the pipe network are complicated, hampering a wider application of the developed techniques. Although a growing number of studies in recent years have considered guided wave propagation across elbows and U-type bends, the topic is still not very well understood for a general bend angle φ, mean bend radius R and pipe thickness b. Here we use 3D Finite Element (FE) simulation to illumine the propagation of fundamental guided pipe modes across bends of several different angles φ. Two different bend radius regimes, R/λ ≈ 1 and 10 (where λ denotes the wavelength of the mode studied) are considered, exemplifying 'sharp' and gradual or 'slow' bends. Different typical pipe thicknesses b within these regimes are also studied. The results confirm the expectation that different bend radius regimes affect the waves differently. Further, while as observed in earlier studies, at moderate bend radii, fundamental modes travel almost unaffected by an elbow (bend angle φ = 90 degrees), we find that as the bend angle is reduced, there is a progressively larger extent of mode-conversion. These trends and results are validated using experiments.

  17. Spherical Coordinate Systems for Streamlining Suited Mobility Analysis

    NASA Technical Reports Server (NTRS)

    Benson, Elizabeth; Cowley, Matthew S.; Harvill. Lauren; Rajulu, Sudhakar

    2014-01-01

    When describing human motion, biomechanists generally report joint angles in terms of Euler angle rotation sequences. However, there are known limitations in using this method to describe complex motions such as the shoulder joint during a baseball pitch. Euler angle notation uses a series of three rotations about an axis where each rotation is dependent upon the preceding rotation. As such, the Euler angles need to be regarded as a set to get accurate angle information. Unfortunately, it is often difficult to visualize and understand these complex motion representations. One of our key functions is to help design engineers understand how a human will perform with new designs and all too often traditional use of Euler rotations becomes as much of a hindrance as a help. It is believed that using a spherical coordinate system will allow ABF personnel to more quickly and easily transmit important mobility data to engineers, in a format that is readily understandable and directly translatable to their design efforts. Objectives: The goal of this project is to establish new analysis and visualization techniques to aid in the examination and comprehension of complex motions. Methods: This project consisted of a series of small sub-projects, meant to validate and verify the method before it was implemented in the ABF's data analysis practices. The first stage was a proof of concept, where a mechanical test rig was built and instrumented with an inclinometer, so that its angle from horizontal was known. The test rig was tracked in 3D using an optical motion capture system, and its position and orientation were reported in both Euler and spherical reference systems. The rig was meant to simulate flexion/extension, transverse rotation and abduction/adduction of the human shoulder, but without the variability inherent in human motion. In the second phase of the project, the ABF estimated the error inherent in a spherical coordinate system, and evaluated how this error would vary within the reference frame. This stage also involved expanding a kinematic model of the shoulder, to include the torso, knees, ankle, elbows, wrists and neck. Part of this update included adding a representation of 'roll' about an axis, for upper arm and lower leg rotations. The third stage of the project involved creating visualization methods to assist in interpreting motion in a spherical frame. This visualization method will be incorporated in a tool to evaluate a database of suited mobility data, which is currently in development.

  18. Does practicing a wide range of joint angle configurations lead to higher flexibility in a manual obstacle-avoidance target-pointing task?

    PubMed Central

    Bootsma, Reinoud J.; Schoemaker, Marina M.; Otten, Egbert; Mouton, Leonora J.; Bongers, Raoul M.

    2017-01-01

    Flexibility in motor actions can be defined as variability in the use of degrees of freedom (e.g., joint angles in the arm) over repetitions while keeping performance (e.g., fingertip position) stabilized. We examined whether flexibility can be increased through enlarging the joint angle range during practice in a manual obstacle-avoidance target-pointing task. To establish differences in flexibility we partitioned the variability in joint angles over repetitions in variability within (GEV) and variability outside the solution space (NGEV). More GEV than NGEV reflects flexibility; when the ratio of the GEV and NGEV is higher, flexibility is higher. The pretest and posttest consisted of 30 repetitions of manual pointing to a target while moving over a 10 cm high obstacle. To enlarge the joint angle range during practice participants performed 600 target-pointing movements while moving over obstacles of different heights (5–9 cm, 11–15 cm). The results indicated that practicing movements over obstacles of different heights led participants to use enlarged range of joint angles compared to the range of joint angles used in movements over the 10 cm obstacle in the pretest. However, for each individual obstacle neither joint angle variance nor flexibility were higher during practice. We also did not find more flexibility after practice. In the posttest, joint angle variance was in fact smaller than before practice, primarily in GEV. The potential influences of learning effects and the task used that could underlie the results obtained are discussed. We conclude that with this specific type of practice in this specific task, enlarging the range of joint angles does not lead to more flexibility. PMID:28700695

  19. Mechanical design of EFW Exo II: A hybrid exoskeleton for elbow-forearm-wrist rehabilitation.

    PubMed

    Bian, Hui; Chen, Ziye; Wang, Hao; Zhao, Tieshi

    2017-07-01

    The use of rehabilitation exoskeleton has become an important means for the treatment of stroke patients. A hybrid exoskeleton named EFW Exo II is developed for the motor function rehabilitation of elbow, forearm and wrist. The EFW Exo II is based on a parallel 2-URR/RRS mechanism and a serial R mechanism. It could fit both left and right arms for the symmetrical and open structure, and the distance between the elbow and wrist could automatically adjust for different forearm length. Details of the mechanical design are introduced. Brushless DC servo motors with planetary gear reducer are used as the actuators of the exoskeleton. Gear drive and belt drive are used for power transmission. A three dimensional force sensor is mounted in the handle to regulate the interaction between the exoskeleton and patient. The EFW Exo II can realize rehabilitation exercise for each joint and the ranges of motion meet the rehabilitation demands of daily living.

  20. Factors affecting the stability of reverse shoulder arthroplasty: a biomechanical study.

    PubMed

    Clouthier, Allison L; Hetzler, Markus A; Fedorak, Graham; Bryant, J Tim; Deluzio, Kevin J; Bicknell, Ryan T

    2013-04-01

    Despite the success of reverse shoulder arthroplasty (RSA) in treating patients with painful pseudoparalytic shoulders, instability is a common complication and currently the factors affecting stability are not well understood. The objective of this study was to investigate a number of factors as well as the interactions between factors to determine how they affect the stability of the prosthesis. These factors included: active arm posture (abduction and abduction plane angles), loading direction, glenosphere diameter and eccentricity, and humeral socket constraint. Force required to dislocate the joint, determined using a biomechanical shoulder simulator, was used as a measure of stability. A factorial design experiment was implemented to examine the factors and interactions. Actively increasing the abduction angle by 15° leads to a 30% increase in stability and use of an inferior-offset rather than a centered glenosphere improved stability by 17%. Use of a more constrained humeral socket also increased stability; but the effect was dependent on loading direction, with a 88% improvement for superior loading, 66% for posterior, 36% for anterior, and no change for inferior loading. Abduction plane angle and glenosphere diameter had no effect on stability. Increased glenohumeral abduction and the use of an inferior-offset glenosphere were found to increase the stability of RSA. Additionally, use of a more constrained humeral socket increased stability for anterior, posterior, and superior loading. These identified factor effects have the potential to decrease the risk of dislocation following RSA. Copyright © 2013 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Mosby, Inc. All rights reserved.

  1. Usage Position and Virtual Keyboard Design Affect Upper-Body Kinematics, Discomfort, and Usability during Prolonged Tablet Typing

    PubMed Central

    Lin, Ming-I Brandon; Hong, Ruei-Hong; Chang, Jer-Hao; Ke, Xin-Min

    2015-01-01

    Purpose The increase in tablet usage allows people to perform computer work in non-traditional office environments. The aim of this study was to assess the effects of changes in tablet keyboard design on postures of the upper extremities and neck, discomfort, and usability under different usage positions during prolonged touch-typing. Methods Eighteen healthy participants familiar with touch-screen devices were randomized into three usage positions (desk, lap, and bed) and completed six, 60-minute typing sessions using three virtual keyboard designs (standard, wide, split). Electrogoniometers continuously measured the postures of the wrists, elbow, and neck. Body discomfort and system usability were evaluated by questionnaires before and immediately after each typing session. Results Separate linear mixed effects models on various postural measures and subjective ratings are conducted with usage position as the between-subject factors, keyboard design and typing duration as the with-in subject factors were conducted. Using the tablet in bed led to more extended wrists but a more natural elbow flexion than the desk position. The angled split virtual keyboard significantly reduced the extent of wrist ulnar deviation than the keyboard with either standard or wide design. However, little difference was observed across the usage position and keyboard design. When the postural data were compared between the middle and end of typing sessions, the wrists, elbow, and neck all exhibited a substantially increased range of joint movements (13% to 38%). The discomfort rating also increased significantly over time in every upper body region investigated. Additionally, the split keyboard design received a higher usability rating in the bed position, whereas participants had more satisfactory experience while using the wide keyboard in the traditional desk setting. Conclusions Prolonged use of tablets in non-traditional office environments may result in awkward postures in the upper body that may expose users to greater risks of developing musculoskeletal symptoms. Adequate virtual keyboard designs show the potential to alleviate some postural effects and improve the user experience without changing the tablet form factors. PMID:26629989

  2. A comparison of the upper limb movement kinematics utilized by children playing virtual and real table tennis.

    PubMed

    Bufton, Amy; Campbell, Amity; Howie, Erin; Straker, Leon

    2014-12-01

    Active virtual games (AVG) may facilitate gross motor skill development, depending on their fidelity. This study compared the movement patterns of nineteen 10-12 yr old children, while playing table tennis on three AVG consoles (Nintendo Wii, Xbox Kinect, Sony Move) and as a real world task. Wrist and elbow joint angles and hand path distance and speed were captured. Children playing real table tennis had significantly smaller (e.g. Wrist Angle Forehand Real-Kinect: Mean Difference (MD): -18.2°, 95% Confidence Interval (CI): -26.15 to -10.26) and slower (e.g. Average Speed Forehand Real-Kinect: MD: -1.98 ms(-1), 95% CI: -2.35 to -1.61) movements than when using all three AVGs. Hand path distance was smaller in forehand and backhand strokes (e.g. Kinect-Wii: MD: 0.46 m, 95% CI: 0.13-0.79) during playing with Kinect than Move and Wii. The movement patterns when playing real and virtual table tennis were different and this may impede the development of real world gross motor skills. Several elements, including display, input and task characteristics, may have contributed to the differences in movement patterns observed. Understanding the interface components for AVGs may help development of higher fidelity games to potentially enhance the development of gross motor skill and thus participation in PA. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Counter-IED PPE Horizon 0, Phase 1 Human Factors Trial: Performance Evaluation of Soft Armour Personal Protective Equipment (Essai Ergonomique du Projet Horizon 0 d’EPI a l’Epreuve des IED, Phase 1: Evaluation du Rendement d’un Equipement de Protection Individual en Materiel Souple)

    DTIC Science & Technology

    2008-03-31

    angle. • Arm Horizontal Plane Adduction o Place the participant’s dominant shoulder in 30° of flexion. o Have the participant flex their elbow to...approximately 90° of flexion. o Have the forearm rotated into the mid-position between supination and pronation. o Have the inclinometer near the elbow ...Grenade Toss Participants were required to toss a tennis ball like a grenade from the prone position to a target approximately 15 m away

  4. Active elbow flexion is possible in C4 quadriplegia using hybrid assistive limb (HAL®) technology: A case study.

    PubMed

    Shimizu, Yukiyo; Kadone, Hideki; Kubota, Shigeki; Ikumi, Akira; Abe, Tetsuya; Marushima, Aiki; Ueno, Tomoyuki; Endo, Ayumu; Kawamoto, Hiroaki; Saotome, Kousaku; Matsushita, Akira; Matsumura, Akira; Sankai, Yoshiyuki; Hada, Yasushi; Yamazaki, Masashi

    2017-07-01

    Patients with complete quadriplegia after high cervical spinal cord injury are fully dependent with activities of daily living. Assistive technology can improve their quality of life. We examined the use of a hybrid assistive limb for single joints (HAL-SJ) in a 19-year-old man with complete C4 quadriplegia due to chronic spinal cord injury to restore function of active elbow flexion. This is the first report on the use of the HAL-SJ in a patient with spinal cord injury. The HAL-SJ intervention for each elbow was administered in 10 sessions. Clinical assessment using surface EMG was conducted to evaluate muscle activity of the trapezius, biceps brachii, infraspinatus, and triceps brachii muscle before, and during the 2nd, 3rd, 6th, and 9th interventions. Surface electromyography (EMG) before intervention showed no contraction in the upper arms, but in the bilateral trapezius. The HAL-SJ used motion intention from the right trapezius for activation. After the 6th and 7th session, respectively, biceps EMG showed that voluntary contraction and right elbow flexion could be performed by motion intention from the right biceps. After the 10th session, voluntary bicep contraction was possible. HAL-SJ treatment on the left elbow was performed using the same protocol with a similar outcome. After completing treatment on both upper extremities, both biceps contracted voluntarily, and he could operate a standard wheelchair for a short distance independently. HAL-SJ intervention is feasible and effective in restoring elbow flexor function in a patient with C4 chronic spinal cord injury and complete quadriplegia.

  5. It's time to change perspective! New diagnostic tools for lateral elbow pain.

    PubMed

    Arrigoni, P; Cucchi, D; Menon, A; Randelli, P

    2017-12-01

    The presence of intra-articular findings that may complement the extra-articular pathology in lateral epicondilytis has been suggested, and a role for minor instability of the elbow as part of the causative process of this disease has been postulated. This study was designed to describe two new clinical tests, aimed at detecting intra-articular pathology in patients affected by recalcitrant lateral epicondylitis and investigate their diagnostic performance. Ten patients suffering of atraumatic lateral elbow pain unresponsive to conservative treatment were considered in this study. Two clinical tests were developed and administrated prior to arthroscopy: Supination and Antero-Lateral pain Test (SALT); Posterior Elbow Pain by Palpation-Extension of the Radiocapitellar joint (PEPPER). Sensitivity, specificity, predictive values and accuracy of SALT and PEPPER as diagnostic tests for seven intra-articular findings were calculated. In 90% of the patients, at least one test was positive. All patients with signs of lateral ligamentous patholaxity or intra-articular abnormal findings had a positive response to at least one of the two tests. SALT proved to have a high sensitivity but a low specificity and is accurate in detecting the presence of intra-articular abnormal findings, especially synovitis. PEPPER test was sensible, specific and accurate in the detection of radial head chondropathy. Two new diagnostic tests (SALT and PEPPER) were specifically designed to evoke pain from intra-articular structures. These tests could be a valid support in the diagnostic algorithm of recalcitrant lateral elbow pain. Positive findings may be indicative of a minor instability of the lateral elbow condition. Diagnostic study, development of diagnostic criteria on basis of consecutive patients, level II.

  6. Altered ulnar nerve kinematic behavior in a cadaver model of entrapment.

    PubMed

    Mahan, Mark A; Vaz, Kenneth M; Weingarten, David; Brown, Justin M; Shah, Sameer B

    2015-06-01

    Ulnar nerve entrapment at the elbow is more than a compressive lesion of the nerve. The tensile biomechanical consequences of entrapment are currently marginally understood. To evaluate the effects of tethering on the kinematics of the ulnar nerve as a model of entrapment neuropathy. The ulnar nerve was exposed in 7 fresh cadaver arms, and markers were placed at 1-cm increments along the nerve, centered on the retrocondylar region. Baseline translation (pure sliding) and strain (stretch) were measured in response to progressively increasing tension produced by varying configurations of elbow flexion and wrist extension. Then the nerves were tethered by suturing to the cubital tunnel retinaculum and again exposed to progressively increasing tension from joint positioning. In the native condition, for all joint configurations, the articular segment of the ulnar nerve exhibited greater strain than segments proximal and distal to the elbow, with a maximum strain of 28 ± 1% and translation of 11.6 ± 1.8 mm distally. Tethering the ulnar nerve suppressed translation, and the distal segment experienced strains that were more than 50% greater than its maximum strain in an untethered state. This work provides a framework for evaluating regional nerve kinematics. Suppressed translation due to tethering shifted the location of high strain from articular to more distal regions of the ulnar nerve. The authors hypothesize that deformation is thus shifted to a region of the nerve less accustomed to high strains, thereby contributing to the development of ulnar neuropathy.

  7. A COMPARISON OF STATIC AND DYNAMIC OPTIMIZATION MUSCLE FORCE PREDICTIONS DURING WHEELCHAIR PROPULSION

    PubMed Central

    Morrow, Melissa M.; Rankin, Jeffery W.; Neptune, Richard R.; Kaufman, Kenton R.

    2014-01-01

    The primary purpose of this study was to compare static and dynamic optimization muscle force and work predictions during the push phase of wheelchair propulsion. A secondary purpose was to compare the differences in predicted shoulder and elbow kinetics and kinematics and handrim forces. The forward dynamics simulation minimized differences between simulated and experimental data (obtained from 10 manual wheelchair users) and muscle co-contraction. For direct comparison between models, the shoulder and elbow muscle moment arms and net joint moments from the dynamic optimization were used as inputs into the static optimization routine. RMS errors between model predictions were calculated to quantify model agreement. There was a wide range of individual muscle force agreement that spanned from poor (26.4 % Fmax error in the middle deltoid) to good (6.4 % Fmax error in the anterior deltoid) in the prime movers of the shoulder. The predicted muscle forces from the static optimization were sufficient to create the appropriate motion and joint moments at the shoulder for the push phase of wheelchair propulsion, but showed deviations in the elbow moment, pronation-supination motion and hand rim forces. These results suggest the static approach does not produce results similar enough to be a replacement for forward dynamics simulations, and care should be taken in choosing the appropriate method for a specific task and set of constraints. Dynamic optimization modeling approaches may be required for motions that are greatly influenced by muscle activation dynamics or that require significant co-contraction. PMID:25282075

  8. Systematic diagnosis and therapy of lateral elbow pain with emphasis on elbow instability.

    PubMed

    Kniesel, Bettina; Huth, Jochen; Bauer, Gerhard; Mauch, Frieder

    2014-12-01

    In recalcitrant epicondylitis innumerable operative techniques have been published, nevertheless a certain percentage of patients remains symptomatic after operative treatment. We developed an individual, systematic diagnostic pathway including arthroscopic assessment of elbow stability to identify the optimal and respectively less invasive therapy. We so far included 40 patients with recalcitrant lateral epicondylitis (mean age 46 ± 11). 5 patients had previous surgery. In all patients, we did an elbow arthroscopy and a systematic arthroscopic stability testing. 25 patients were treated exclusively arthroscopically once instability was excluded. In 13 patients with slight instability, we did an open debridement of the lateral tendon complex and local refixation. Two patients with severe instability were treated with open debridement and additional stabilization of the LUCL with a trizeps graft. With a minimum follow-up of 1 year, we assessed the DASH score and subjective patient satisfaction. Mean follow-up was 24 ± 12 months, mean duration of symptoms before surgery was 19 ± 18 months. The mean DASH score at follow-up was 22 ± 19.36 patients reported symptoms improvement, 34 patients would repeat surgery given the same situation; in 30 cases, patients expectations had been fulfilled. We did not observe any intraoperative complications or infections. One patient developed joint stiffness requiring reoperation. Using a systematic diagnostic pathway including assessment of elbow stability and consecutive individualized, respectively, less invasive surgical procedure we acquired high patients satisfaction and good clinical outcome with a low complication rate. Level III.

  9. The effects of a repeated bout of eccentric exercise on indices of muscle damage and delayed onset muscle soreness.

    PubMed

    Paddon-Jones, D; Muthalib, M; Jenkins, D

    2000-03-01

    This study examined markers of muscle damage following a repeated bout of maximal isokinetic eccentric exercise performed prior to full recovery from a previous bout. Twenty non-resistance trained volunteers were randomly assigned to a control (CON, n=10) or experimental (EXP, n=10) group. Both groups performed 36 maximal isokinetic eccentric contractions of the elbow flexors of the non-dominant arm (ECC1). The EXP group repeated the same eccentric exercise bout two days later (ECC2). Total work and peak eccentric torque were recorded during each set of ECC1 and ECC2. Isometric torque, delayed onset muscle soreness (DOMS), flexed elbow angle and plasma creatine kinase (CK) activity were measured prior to and immediately following ECC1 and ECC2. at 24h intervals for 7 days following ECC1 and finally on day 11. In both groups, all dependent variables changed significantly during the 2 days following ECC1. A further acute post-exercise impairment in isometric torque (30 +/- 5%) and flexed elbow angle (20 +/- 4%) was observed following ECC2 (p<0.05), despite EXP subjects producing uniformly lower work and peak eccentric torque values during ECC2 (p<0.05). No other significant differences between the CON and EXP groups were observed throughout the study (p>0.05). These findings suggest that when maximal isokinetic eccentric exercise is repeated two days after experiencing of contraction-induced muscle damage, the recovery time course is not significantly altered.

  10. A painless and constraint-free method to estimate viscoelastic passive dynamics of limbs' joints to support diagnosis of neuromuscular diseases.

    PubMed

    Venture, Gentiane; Nakamura, Yoshihiko; Yamane, Katsu; Hirashima, Masaya

    2007-01-01

    Though seldom identified, the human joints dynamics is important in the fields of medical robotics and medical research. We present a general solution to estimate in-vivo and simultaneously the passive dynamics of the human limbs' joints. It is based on the use of the multi-body description of the human body and its kinematics and dynamics computations. The linear passive joint dynamics of the shoulders and the elbows: stiffness, viscosity and friction, is estimated simultaneously using the linear least squares method. Acquisition of movements is achieved with an optical motion capture studio on one examinee during the clinical diagnosis of neuromuscular diseases. Experimental results are given and discussed.

  11. A practical guide for performing arthrography under fluoroscopic or ultrasound guidance.

    PubMed

    Lungu, Eugen; Moser, Thomas P

    2015-12-01

    We propose a practical approach for performing arthrography with fluoroscopic or ultrasound guidance. Different approaches to the principal joints of the upper limb (shoulder, elbow, wrist and fingers), lower limb (hip, knee, ankle and foot) as well as the facet joints of the spine are discussed and illustrated with numerous drawings. Whenever possible, we emphasise the concept of targeting articular recesses, which offers many advantages over traditional techniques aiming at the joint space. • Arthrography remains a foremost technique in musculoskeletal radiology • Most joints can be successfully accessed by targeting the articular recess • Targeting the recess offers several advantages over traditional approaches • Ultrasound-guidance is now favoured over fluoroscopy and targeting the recess is equally applicable.

  12. Contact mechanics of reverse total shoulder arthroplasty during abduction: the effect of neck-shaft angle, humeral cup depth, and glenosphere diameter.

    PubMed

    Langohr, G Daniel G; Willing, Ryan; Medley, John B; Athwal, George S; Johnson, James A

    2016-04-01

    Implant design parameters can be changed during reverse shoulder arthroplasty (RSA) to improve range of motion and stability; however, little is known regarding their impact on articular contact mechanics. The purpose of this finite element study was to investigate RSA contact mechanics during abduction for different neck-shaft angles, glenosphere sizes, and polyethylene cup depths. Finite element RSA models with varying neck-shaft angles (155°, 145°, 135°), sizes (38 mm, 42 mm), and cup depths (deep, normal, shallow) were loaded with 400 N at physiological abduction angles. The contact area and maximum contact stress were computed. The contact patch and the location of maximum contact stress were typically located inferomedially in the polyethylene cup. On average for all abduction angles investigated, reducing the neck-shaft angle reduced the contact area by 29% for 155° to 145° and by 59% for 155° to 135° and increased maximum contact stress by 71% for 155° to 145° and by 286% for 155° to 135°. Increasing the glenosphere size increased the contact area by 12% but only decreased maximum contact stress by 2%. Decreasing the cup depth reduced the contact area by 40% and increased maximum contact stress by 81%, whereas increasing the depth produced the opposite effect (+52% and -36%, respectively). The location of the contact patch and maximum contact stress in this study matches the area of damage seen frequently on clinical retrievals. This finding suggests that damage to the inferior cup due to notching may be potentiated by contact stresses. Increasing the glenosphere diameter improved the joint contact area and did not affect maximum contact stress. However, although reducing the neck-shaft angle and cup depth can improve range of motion, our study shows that this also has some negative effects on RSA contact mechanics, particularly when combined. Copyright © 2016 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  13. Muscle torque and its relation to technique, tactics, sports level and age group in judo contestants.

    PubMed

    Lech, Grzegorz; Chwała, Wiesław; Ambroży, Tadeusz; Sterkowicz, Stanisław

    2015-03-29

    The aim of this study was to perform a comparative analysis of maximal muscle torques at individual stages of development of athletes and to determine the relationship between muscle torques, fighting methods and the level of sports performance. The activity of 25 judo contestants during judo combats and the effectiveness of actions were evaluated. Maximum muscle torques in flexors/extensors of the body trunk, shoulder, elbow, hip and knee joints were measured. The level of significance was set at p≤0.05; for multiple comparisons the Mann-Whitney U test, p≤0.016, was used. Intergroup differences in relative torques in five muscle groups studied (elbow extensors, shoulder flexors, knee flexors, knee extensors, hip flexors) were not significant. In cadets, relative maximum muscle torques in hip extensors correlated with the activity index (Spearman's r=0.756). In juniors, maximum relative torques in elbow flexors and knee flexors correlated with the activity index (r=0.73 and r=0.76, respectively). The effectiveness of actions correlated with relative maximum torque in elbow extensors (r=0.67). In seniors, the relative maximum muscle torque in shoulder flexors correlated with the activity index during the second part of the combat (r=0.821).

  14. Muscle Torque and its Relation to Technique, Tactics, Sports Level and Age Group in Judo Contestants

    PubMed Central

    Lech, Grzegorz; Chwała, Wiesław; Ambroży, Tadeusz; Sterkowicz, Stanisław

    2015-01-01

    The aim of this study was to perform a comparative analysis of maximal muscle torques at individual stages of development of athletes and to determine the relationship between muscle torques, fighting methods and the level of sports performance. The activity of 25 judo contestants during judo combats and the effectiveness of actions were evaluated. Maximum muscle torques in flexors/extensors of the body trunk, shoulder, elbow, hip and knee joints were measured. The level of significance was set at p≤0.05; for multiple comparisons the Mann-Whitney U test, p≤0.016, was used. Intergroup differences in relative torques in five muscle groups studied (elbow extensors, shoulder flexors, knee flexors, knee extensors, hip flexors) were not significant. In cadets, relative maximum muscle torques in hip extensors correlated with the activity index (Spearman’s r=0.756). In juniors, maximum relative torques in elbow flexors and knee flexors correlated with the activity index (r=0.73 and r=0.76, respectively). The effectiveness of actions correlated with relative maximum torque in elbow extensors (r=0.67). In seniors, the relative maximum muscle torque in shoulder flexors correlated with the activity index during the second part of the combat (r=0.821). PMID:25964820

  15. Quantifying selective elbow movements during an exergame in children with neurological disorders: a pilot study.

    PubMed

    van Hedel, Hubertus J A; Häfliger, Nadine; Gerber, Corinna N

    2016-10-21

    It is difficult to distinguish between restorative and compensatory mechanisms underlying (pediatric) neurorehabilitation, as objective measures assessing selective voluntary motor control (SVMC) are scarce. We aimed to quantify SVMC of elbow movements in children with brain lesions. Children played an airplane game with the glove-based YouGrabber system. Participants were instructed to steer an airplane on a screen through a cloud-free path by correctly applying bilateral elbow flexion and extension movements. Game performance measures were (i) % time on the correct path and (ii) similarity between the ideal flight path and the actually flown path. SVMC was quantified by calculating a correlation coefficient between the derivative of the ideal path and elbow movements. A therapist scored whether the child had used compensatory movements. Thirty-three children with brain lesions (11 girls; 12.6 ± 3.6 years) participated. Clinical motor and cognitive scores correlated moderately with SVMC (0.50-0.74). Receiver Operating Characteristics analyses showed that SVMC could differentiate well and better than clinical and game performance measures between compensatory and physiological movements. We conclude that a simple measure assessed while playing a game appears promising in quantifying SVMC. We propose how to improve the methodology, and how this approach can be easily extended to other joints.

  16. Parametric analysis of a shape memory alloy actuated arm

    NASA Astrophysics Data System (ADS)

    Wright, Cody; Bilgen, Onur

    2016-04-01

    Using a pair of antagonistic Shape Memory Allow (SMA) wires, it may be possible to produce a mechanism that replicates human musculoskeletal movement. The movement of interest is the articulation of the elbow joint actuated by the biceps brachii muscle. In an effort to understand the bio-mechanics of the arm, a single degree of freedom crankslider mechanism is used to model the movement of the arm induced by the biceps brachii muscle. First, a purely kinematical analysis is performed on a rigid body crank-slider. Force analysis is also done modeling the muscle as a simple linear spring. Torque, rocking angle, and energy are calculated for a range of crank-slider geometries. The SMA wire characteristics are experimentally determined for the martensite detwinned and full austenite phases. Using the experimental data, an idealized actuator characteristic curve is produced for the SMA wire. Kinematic and force analyses are performed on the nonlinear wire characteristic curve and a linearized wire curve; both cases are applied to the crankslider mechanism. Performance metrics for both cases are compared, followed by discussion.

  17. Fusimotor control of spindle sensitivity regulates central and peripheral coding of joint angles.

    PubMed

    Lan, Ning; He, Xin

    2012-01-01

    Proprioceptive afferents from muscle spindles encode information about peripheral joint movements for the central nervous system (CNS). The sensitivity of muscle spindle is nonlinearly dependent on the activation of gamma (γ) motoneurons in the spinal cord that receives inputs from the motor cortex. How fusimotor control of spindle sensitivity affects proprioceptive coding of joint position is not clear. Furthermore, what information is carried in the fusimotor signal from the motor cortex to the muscle spindle is largely unknown. In this study, we addressed the issue of communication between the central and peripheral sensorimotor systems using a computational approach based on the virtual arm (VA) model. In simulation experiments within the operational range of joint movements, the gamma static commands (γ(s)) to the spindles of both mono-articular and bi-articular muscles were hypothesized (1) to remain constant, (2) to be modulated with joint angles linearly, and (3) to be modulated with joint angles nonlinearly. Simulation results revealed a nonlinear landscape of Ia afferent with respect to both γ(s) activation and joint angle. Among the three hypotheses, the constant and linear strategies did not yield Ia responses that matched the experimental data, and therefore, were rejected as plausible strategies of spindle sensitivity control. However, if γ(s) commands were quadratically modulated with joint angles, a robust linear relation between Ia afferents and joint angles could be obtained in both mono-articular and bi-articular muscles. With the quadratic strategy of spindle sensitivity control, γ(s) commands may serve as the CNS outputs that inform the periphery of central coding of joint angles. The results suggest that the information of joint angles may be communicated between the CNS and muscles via the descending γ(s) efferent and Ia afferent signals.

  18. Effect of knee joint angle on neuromuscular activation of the vastus intermedius muscle during isometric contraction.

    PubMed

    Watanabe, K; Akima, H

    2011-12-01

    The purpose of this study was to compare the relationship between surface electromyography (EMG) and knee joint angle of the vastus intermedius muscle (VI) with the synergistic muscles in the quadriceps femoris (QF) muscle group. Fourteen healthy men performed maximal voluntary contractions during isometric knee extension at four knee joint angles from 90°, 115°, 140°, and 165° (180° being full extension). During the contractions, surface EMG was recorded at four muscle components of the QF muscle group: the VI, vastus lateralis (VL), vastus medialis (VM), and rectus femoris (RF) muscles. The root mean square of the surface EMG at each knee joint angle was calculated and normalized by that at a knee joint angle of 90° for individual muscles. The normalized RMS of the VI muscle was significantly lower than those of the VL and RF muscles at the knee joint angles of 115° and 165° and those of the VL, VM, and RF muscles at the knee joint angle of 140° (P<0.05). The present results suggest that the neuromuscular activation of the VI muscle is regulated in a manner different from the alteration of the knee joint angle compared with other muscle components of the QF muscle group. © 2011 John Wiley & Sons A/S.

  19. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  20. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  1. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  2. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  3. 21 CFR 888.3150 - Elbow joint metal/polymer constrained cemented prosthesis.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... use with bone cement (§ 888.3027). (b) Classification. Class II. The special controls for this device...) “Guidance Document for Testing Orthopedic Implants with Modified Metallic Surfaces Apposing Bone or Bone... Biomaterials (Nonporous) for Surgical Implant with Respect to Effect of Material on Muscle and Bone,” (v) F...

  4. Planning Paths Through Singularities in the Center of Mass Space

    NASA Technical Reports Server (NTRS)

    Doggett, William R.; Messner, William C.; Juang, Jer-Nan

    1998-01-01

    The center of mass space is a convenient space for planning motions that minimize reaction forces at the robot's base or optimize the stability of a mechanism. A unique problem associated with path planning in the center of mass space is the potential existence of multiple center of mass images for a single Cartesian obstacle, since a single center of mass location can correspond to multiple robot joint configurations. The existence of multiple images results in a need to either maintain multiple center of mass obstacle maps or to update obstacle locations when the robot passes through a singularity, such as when it moves from an elbow-up to an elbow-down configuration. To illustrate the concepts presented in this paper, a path is planned for an example task requiring motion through multiple center of mass space maps. The object of the path planning algorithm is to locate the bang- bang acceleration profile that minimizes the robot's base reactions in the presence of a single Cartesian obstacle. To simplify the presentation, only non-redundant robots are considered and joint non-linearities are neglected.

  5. Elbow functional compensation using a lightweight magnetorheological clutch.

    PubMed

    Clemente, Alejandro Martín; Caballero, Antonio Flores; Rojas, Dolores Blanco; Copaci, Dorin-Sabin; Lorente, Luis Moreno

    2011-01-01

    There are many applications for which a patient needs functional compensation due to motor disorders in daily activities. Classic research has focused on robotics solutions in terms of actuators or motors, but the point of this paper is to analyze new solutions combining both biological and artificial structures, in order to improve standard developments. Nowadays wearable Robots are taking an important role in rehabilitation purposes, due to this issue lots of new designs are emerging, but most of them are not still prepared to be used in terms of autonomy, weight, etc. Under the Hybrid Neuroprosthetic and Neurorobotic devices for Functional Compensation and Rehabilitation (HYPER) project, new actuator technologies have been developed in order to improve the adaptability and portability of rehabilitation devices. The designed device is based on a lightweight magnetorheological (MR) clutch which is able to transmit torque from a motor to the injured joint. Though it is intended to work in human upper limb (elbow mainly), other future designs will also be studied for other human joints. Simulation results using Simulink®, MSC Adams®and MSMS®are reported to illustrate the viability of the proposed device.

  6. Arthroscopic Treatment of Annular Drive Through and Radial Lateral Collateral Ligament Articular-Side Tear of the Elbow.

    PubMed

    Arrigoni, Paolo; D'Ambrosi, Riccardo; Randelli, Pietro

    2015-12-01

    An elongation or partial articular-sided tear of the radial lateral collateral ligament (R-LCL) is a rare injury causing disability and instability of the elbow. In our experience this condition is often associated with a pathologic sign of the annular ligament named the "annular drive through" caused by a redundancy of the ligament. The benefits of performing an arthroscopic procedure for surgical stabilization of the R-LCL include smaller incisions with less soft-tissue dissection, better visualization of the joint, better repair accessibility, and elimination of the annular drive-through sign. The main steps of the operation are as follows: evaluation of annular drive through, inspection of the radial side of the joint, anterior capsulotomy, insertion of a suture anchor through the anterolateral portal, shuttling of the suture anchor through the ligament, and elimination of the annular drive-through sign. By use of this technique, it is possible to repair a lesion of the R-LCL with a suture anchor that ensures an anatomic repair and, at the same time, returns the annular ligament to its physiological tension.

  7. Effect of distal ulnar collateral ligament tear pattern on contact forces and valgus stability in the posteromedial compartment of the elbow.

    PubMed

    Hassan, Sheref E; Parks, Brent G; Douoguih, Wiemi A; Osbahr, Daryl C

    2015-02-01

    It is not known whether the pattern of ulnar collateral ligament (UCL) tear affects elbow biomechanics. There will be a significant change in elbow biomechanics with 50% proximal but not 50% distal simulated rupture of the UCL. Controlled laboratory study. Pressure sensors in the posteromedial elbow joint of 25 male cadaveric elbows (average age, 54.9 years; range, 26-66 years) were used to measure contact area, pressure, and valgus torque at 90° and 30° of elbow flexion. Thirteen specimens were tested with the UCL intact, then with proximal-to-distal detachment of 50%, and then with proximal-to-distal detachment of 100% of the anterior band of the UCL from the ulnar attachment. This method was repeated in the remaining 12 specimens in a distal-to-proximal direction. With 50% proximal-to-distal detachment, contact area decreased significantly versus intact at 90° (91.3 ± 23.6 vs 112.2 ± 26.0 mm(2); P < .001) and 30° (69.3 ± 14.8 vs 83.1 ± 21.6 mm(2); P < .001) of elbow flexion; the center of pressure (COP) moved significantly proximally versus intact at 90° (3.8 ± 2.5 vs 5.4 ± 2.3 mm; P < .001) and 30° (5.9 ± 2.8 vs 7.4±1.9 mm; P < .001). With 50% distal-to-proximal UCL detachment versus intact, no significant change was observed in contact area, movement of the COP, or valgus laxity at either flexion position. With 100% proximal-to-distal and distal-to-proximal detachment, significant change in contact area, movement of the COP, and valgus laxity versus intact was found at 90° and 30° of elbow flexion (P < .05). No significant difference in contact pressure was observed in any test conditions. Significant change in contact area and proximal movement of the COP with 50% proximal UCL detachment and the lack of significant change with 50% distal UCL detachment suggest that the proximal half of the UCL ulnar footprint has a primary role in maintaining posteromedial elbow biomechanics. The findings suggest that surgical reconstruction should aim to reestablish at least the proximal 50% of the UCL ulnar footprint. © 2014 The Author(s).

  8. Effect of the Angle Between Sn Grain c-Axis and Electron Flow Direction on Cu-Reinforced Composite Solder Joints Under Current Stressing

    NASA Astrophysics Data System (ADS)

    Wang, Yan; Han, Jing; Wang, Yishu; Ma, Limin; Guo, Fu

    2018-01-01

    With a body-centered tetragonal crystal structure, Sn grains were demonstrated to have highly anisotropic behaviors in various properties. The electromigration behavior of lead-free solder was impacted by the grain orientations. In this paper, the angle between the c-axis and the electron flow direction in composite solder joints (angle θ) was proven to be an important factor during electromigration. The effects of angle θ on the electromigration of composite solder joints were investigated in this paper. Cu particle-reinforced Sn3.5Ag solder joints were stressed under a current density of 104 A/cm2 at room temperature. After 336 h current stressing time, different electromigration phenomena occurred at the two sides of the grain boundary in the composite solder joint which contained two Sn grains with different angle θ. The Sn grains with the larger angle θ had a smaller growth rate of Cu6Sn5. In addition, a composite solder joint with a single Sn grain was set as the contrast and its angle θ was smaller than that of the composite solder joint with two Sn grains. The growth rate of Cu6Sn5 in the composite solder joint with a single grain was faster than that of the composite solder joint with two Sn grains.

  9. Proximal Versus Distal Control of Two-Joint Planar Reaching Movements in the Presence of Neuromuscular Noise

    PubMed Central

    Nguyen, Hung P.; Dingwell, Jonathan B.

    2012-01-01

    Determining how the human nervous system contends with neuro-motor noise is vital to understanding how humans achieve accurate goal-directed movements. Experimentally, people learning skilled tasks tend to reduce variability in distal joint movements more than in proximal joint movements. This suggests that they might be imposing greater control over distal joints than proximal joints. However, the reasons for this remain unclear, largely because it is not experimentally possible to directly manipulate either the noise or the control at each joint independently. Therefore, this study used a 2 degree-of-freedom torque driven arm model to determine how different combinations of noise and/or control independently applied at each joint affected the reaching accuracy and the total work required to make the movement. Signal-dependent noise was simultaneously and independently added to the shoulder and elbow torques to induce endpoint errors during planar reaching. Feedback control was then applied, independently and jointly, at each joint to reduce endpoint error due to the added neuromuscular noise. Movement direction and the inertia distribution along the arm were varied to quantify how these biomechanical variations affected the system performance. Endpoint error and total net work were computed as dependent measures. When each joint was independently subjected to noise in the absence of control, endpoint errors were more sensitive to distal (elbow) noise than to proximal (shoulder) noise for nearly all combinations of reaching direction and inertia ratio. The effects of distal noise on endpoint errors were more pronounced when inertia was distributed more toward the forearm. In contrast, the total net work decreased as mass was shifted to the upper arm for reaching movements in all directions. When noise was present at both joints and joint control was implemented, controlling the distal joint alone reduced endpoint errors more than controlling the proximal joint alone for nearly all combinations of reaching direction and inertia ratio. Applying control only at the distal joint was more effective at reducing endpoint errors when more of the mass was more proximally distributed. Likewise, controlling the distal joint alone required less total net work than controlling the proximal joint alone for nearly all combinations of reaching distance and inertia ratio. It is more efficient to reduce endpoint error and energetic cost by selectively applying control to reduce variability in the distal joint than the proximal joint. The reasons for this arise from the biomechanical configuration of the arm itself. PMID:22757504

  10. Proximal versus distal control of two-joint planar reaching movements in the presence of neuromuscular noise.

    PubMed

    Nguyen, Hung P; Dingwell, Jonathan B

    2012-06-01

    Determining how the human nervous system contends with neuro-motor noise is vital to understanding how humans achieve accurate goal-directed movements. Experimentally, people learning skilled tasks tend to reduce variability in distal joint movements more than in proximal joint movements. This suggests that they might be imposing greater control over distal joints than proximal joints. However, the reasons for this remain unclear, largely because it is not experimentally possible to directly manipulate either the noise or the control at each joint independently. Therefore, this study used a 2 degree-of-freedom torque driven arm model to determine how different combinations of noise and/or control independently applied at each joint affected the reaching accuracy and the total work required to make the movement. Signal-dependent noise was simultaneously and independently added to the shoulder and elbow torques to induce endpoint errors during planar reaching. Feedback control was then applied, independently and jointly, at each joint to reduce endpoint error due to the added neuromuscular noise. Movement direction and the inertia distribution along the arm were varied to quantify how these biomechanical variations affected the system performance. Endpoint error and total net work were computed as dependent measures. When each joint was independently subjected to noise in the absence of control, endpoint errors were more sensitive to distal (elbow) noise than to proximal (shoulder) noise for nearly all combinations of reaching direction and inertia ratio. The effects of distal noise on endpoint errors were more pronounced when inertia was distributed more toward the forearm. In contrast, the total net work decreased as mass was shifted to the upper arm for reaching movements in all directions. When noise was present at both joints and joint control was implemented, controlling the distal joint alone reduced endpoint errors more than controlling the proximal joint alone for nearly all combinations of reaching direction and inertia ratio. Applying control only at the distal joint was more effective at reducing endpoint errors when more of the mass was more proximally distributed. Likewise, controlling the distal joint alone required less total net work than controlling the proximal joint alone for nearly all combinations of reaching distance and inertia ratio. It is more efficient to reduce endpoint error and energetic cost by selectively applying control to reduce variability in the distal joint than the proximal joint. The reasons for this arise from the biomechanical configuration of the arm itself.

  11. Estimation of Finger Joint Angles Based on Electromechanical Sensing of Wrist Shape.

    PubMed

    Kawaguchi, Junki; Yoshimoto, Shunsuke; Kuroda, Yoshihiro; Oshiro, Osamu

    2017-09-01

    An approach to finger motion capture that places fewer restrictions on the usage environment and actions of the user is an important research topic in biomechanics and human-computer interaction. We proposed a system that electrically detects finger motion from the associated deformation of the wrist and estimates the finger joint angles using multiple regression models. A wrist-mounted sensing device with 16 electrodes detects deformation of the wrist from changes in electrical contact resistance at the skin. In this study, we experimentally investigated the accuracy of finger joint angle estimation, the adequacy of two multiple regression models, and the resolution of the estimation of total finger joint angles. In experiments, both the finger joint angles and the system output voltage were recorded as subjects performed flexion/extension of the fingers. These data were used for calibration using the least-squares method. The system was found to be capable of estimating the total finger joint angle with a root-mean-square error of 29-34 degrees. A multiple regression model with a second-order polynomial basis function was shown to be suitable for the estimation of all total finger joint angles, but not those of the thumb.

  12. Ultrasonic scanning system for in-place inspection of brazed tube joints

    NASA Technical Reports Server (NTRS)

    Haynes, J. L.; Wages, C. G.; Haralson, H. S. (Inventor)

    1973-01-01

    A miniaturized ultrasonic scanning system for nondestructive in-place, non-immersion testing of brazed joints in stainless-steel tubing is described. The system is capable of scanning brazed tube joints, with limited clearance access, in 1/4 through 5/8 inch union, tee, elbow and cross configurations. The system has the capability to detect defective conditions now associated with material density changes in addition to those which are depended upon density variations. The system includes a miniaturized scanning head assembly that fits around a tube joint and rotates the transducer around and down the joint in a continuous spiral motion. The C-scan recorder is similar in principle to conventional models except that it was specially designed to track the continuous spiral scan of the tube joint. The scanner and recorder can be operated with most commercially available ultrasonic flaw detectors.

  13. Robotic Arm Manipulator Using Active Control for Sample Acquisition and Transfer, and Passive Mode for Surface Compliance

    NASA Technical Reports Server (NTRS)

    Liu, Jun; Underhill, Michael L.; Trease, Brian P.; Lindemann, Randel A.

    2010-01-01

    A robotic arm that consists of three joints with four degrees of freedom (DOF) has been developed. It can carry an end-effector to acquire and transfer samples by using active control and comply with surface topology in a passive mode during a brief surface contact. The three joints are arranged in such a way that one joint of two DOFs is located at the shoulder, one joint of one DOF is located at the elbow, and one joint of one DOF is located at the wrist. Operationally, three DOFs are moved in the same plane, and the remaining one on the shoulder is moved perpendicular to the other three for better compliance with ground surface and more flexibility of sample handling. Three out of four joints are backdriveable, making the mechanism less complex and more cost effective

  14. Control of joint motion simulators for biomechanical research

    NASA Technical Reports Server (NTRS)

    Colbaugh, R.; Glass, K.

    1992-01-01

    The authors present a hierarchical adaptive algorithm for controlling upper extremity human joint motion simulators. A joint motion simulator is a computer-controlled, electromechanical system which permits the application of forces to the tendons of a human cadaver specimen in such a way that the cadaver joint under study achieves a desired motion in a physiologic manner. The proposed control scheme does not require knowledge of the cadaver specimen dynamic model, and solves on-line the indeterminate problem which arises because human joints typically possess more actuators than degrees of freedom. Computer simulation results are given for an elbow/forearm system and wrist/hand system under hierarchical control. The results demonstrate that any desired normal joint motion can be accurately tracked with the proposed algorithm. These simulation results indicate that the controller resolved the indeterminate problem redundancy in a physiologic manner, and show that the control scheme was robust to parameter uncertainty and to sensor noise.

  15. Interdependence of torque, joint angle, angular velocity and muscle action during human multi-joint leg extension.

    PubMed

    Hahn, Daniel; Herzog, Walter; Schwirtz, Ansgar

    2014-08-01

    Force and torque production of human muscles depends upon their lengths and contraction velocity. However, these factors are widely assumed to be independent of each other and the few studies that dealt with interactions of torque, angle and angular velocity are based on isolated single-joint movements. Thus, the purpose of this study was to determine force/torque-angle and force/torque-angular velocity properties for multi-joint leg extensions. Human leg extension was investigated (n = 18) on a motor-driven leg press dynamometer while measuring external reaction forces at the feet. Extensor torque in the knee joint was calculated using inverse dynamics. Isometric contractions were performed at eight joint angle configurations of the lower limb corresponding to increments of 10° at the knee from 30 to 100° of knee flexion. Concentric and eccentric contractions were performed over the same range of motion at mean angular velocities of the knee from 30 to 240° s(-1). For contractions of increasing velocity, optimum knee angle shifted from 52 ± 7 to 64 ± 4° knee flexion. Furthermore, the curvature of the concentric force/torque-angular velocity relations varied with joint angles and maximum angular velocities increased from 866 ± 79 to 1,238 ± 132° s(-1) for 90-50° knee flexion. Normalised eccentric forces/torques ranged from 0.85 ± 0.12 to 1.32 ± 0.16 of their isometric reference, only showing significant increases above isometric and an effect of angular velocity for joint angles greater than optimum knee angle. The findings reveal that force/torque production during multi-joint leg extension depends on the combined effects of angle and angular velocity. This finding should be accounted for in modelling and optimisation of human movement.

  16. Motion control of 7-DOF arms - The configuration control approach

    NASA Technical Reports Server (NTRS)

    Seraji, Homayoun; Long, Mark K.; Lee, Thomas S.

    1993-01-01

    Graphics simulation and real-time implementation of configuration control schemes for a redundant 7-DOF Robotics Research arm are described. The arm kinematics and motion control schemes are described briefly. This is followed by a description of a graphics simulation environment for 7-DOF arm control on the Silicon Graphics IRIS Workstation. Computer simulation results are presented to demonstrate elbow control, collision avoidance, and optimal joint movement as redundancy resolution goals. The laboratory setup for experimental validation of motion control of the 7-DOF Robotics Research arm is then described. The configuration control approach is implemented on a Motorola-68020/VME-bus-based real-time controller, with elbow positioning for redundancy resolution. Experimental results demonstrate the efficacy of configuration control for real-time control.

  17. Comparison of Two Methods for Estimating Adjustable One-Point Cane Length in Community-Dwelling Older Adults.

    PubMed

    Camara, Camila Thais Pinto; de Freitas, Sandra Maria Sbeghen Ferreira; de Lima, Waléria Paixão; Lima, Camila Astolphi; Amorim, César Ferreira; Perracini, Monica Rodrigues

    2017-01-01

    Our aim is to estimate inter-observer reliability, test-retest reliability, anthropometric and biomechanical adequacy and minimal detectable change when measuring the length of single-point adjustable canes in community-dwelling older adults. There are 112 participants in the study. They are men and women, aged 60 years and over, who were attending an outpatient community health centre. An exploratory study design was used. Participants underwent two assessments within the same day by two independent observers and by the same observer at an interval of 15-45 days. Two measures were used to establish the length of a single-point adjustable cane: the distance from the distal wrist crease to the floor (WF) and the distance from the top of the greater trochanter of the femur to the floor (TF). Each individual was fitted according to these two measures, and elbow flexion angle was measured. Inter-observer reliability and the test-retest reliability were high in both TF (ICC 3.1  = 0.918 and ICC 2.1  = 0.935) and WF measures (ICC 3.1  = 0.967 and ICC 2.1  = 0.960). Only 1% of the individuals kept an elbow flexion angle within the standard recommendation of 30° ± 10° when the cane length was determined by the TF measure, and 30% of the participants when the cane was determined by the WF measure. The minimal detectable cane length change was 2.2 cm. Our results suggest that, even though both measures are reliable, cane length determined by WF distance is more appropriate to keep the elbow flexion angle within the standard recommendation. The minimal detectable change corresponds to approximately a hole in the cane adjustment. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.

  18. Hemophilic Chronic Synovitis: Therapy of Hemarthrosis using Endovascular Embolization of Knee and Elbow Arteries

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Galli, E., E-mail: emgalli1@yahoo.com.ar; Baques, A.; Moretti, N.

    2013-08-01

    PurposeCongenital hemophilia is a hereditary bleeding disorder that affects 1 in 5,000 males and is characterized by repetitive musculoskeletal bleeding episodes. Selective embolization of the knee and elbow arteries can prevent bleeding episodes. To evaluate the long-term efficacy of these procedures, we assessed the outcomes of 30 procedures performed in our center.MethodsWe performed 30 procedures in 27 hemophilic patients, including 23 knee, and 7 elbow procedures. To evaluate the efficacy of selective embolization of knee and elbow arteries in people with hemophilia, we analyzed the number of bleeding episodes during 12 months before the procedure compared with the amount ofmore » episodes that occurred 3, 6, and 12 months after embolization.ResultsTwenty-nine of 30 procedures were classified as successful. The median of 1.25 episodes per month (range 0-3) observed before the procedure was reduced to 0 (range 0-1.67; p < 0.001) at 3 months, 0.17 (range 0-1.67; p < 0.001) at 6 months, and 0.33 (range 0-1.67; p = 0.024) at 12 months. Three patients remained free of bleeding events for more than 6 months. Additionally, after the procedure there was a significant reduction in factor FVIII usage that sustained up to 12 months after the procedures. No serious adverse events were observed.ConclusionsSelective angiographic embolization of knee and elbow arteries is a feasible procedure that can prevent repetitive bleedings, which would translate in better joint outcomes for these patients.« less

  19. Hip and knee joints are more stabilized than driven during the stance phase of gait: an analysis of the 3D angle between joint moment and joint angular velocity.

    PubMed

    Dumas, R; Cheze, L

    2008-08-01

    Joint power is commonly used in orthopaedics, ergonomics or sports analysis but its clinical interpretation remains controversial. Some basic principles on muscle actions and energy transfer have been proposed in 2D. The decomposition of power on 3 axes, although questionable, allows the same analysis in 3D. However, these basic principles have been widely criticized, mainly because bi-articular muscles must be considered. This requires a more complex computation in order to determine how the individual muscle force contributes to drive the joint. Conversely, with simple 3D inverse dynamics, the analysis of both joint moment and angular velocity directions is essential to clarify when the joint moment can contribute or not to drive the joint. The present study evaluates the 3D angle between the joint moment and the joint angular velocity and investigates when the hip, knee and ankle joints are predominantly driven (angle close to 0 degrees and 180 degrees ) or stabilized (angle close to 90 degrees ) during gait. The 3D angle curves show that the three joints are never fully but only partially driven and that the hip and knee joints are mainly stabilized during the stance phase. The notion of stabilization should be further investigated, especially for subjects with motion disorders or prostheses.

  20. [Relationship between muscle activity and kinematics of the lower extremity in slow motions of squats in humans].

    PubMed

    Khorievin, V I; Horkovenko, A V; Vereshchaka, I V

    2013-01-01

    Squatting can be performed on ankle strategy when ankle joint is flexed more than a hip joint and on hip strategy when large changes occur at the hip joint. The relationships between changes ofjoint angles and electromyogram (EMG) of the leg muscles were studied in five healthy men during squatting that was performed at the ankle and hip strategies with a slow changes in the knee angle of 40 and 60 degrees. It is established that at ankle strategy the ankle muscles were activated ahead of joint angle changes and shifting the center of pressure (CT) on stabilographic platform, whereas activation of the thigh muscles began simultaneously with the change of the joint angles, showing the clear adaptation in successive trials and a linear relationships between the static EMG component and the angle changes of the ankle joint. In the case of hip strategy of squatting the thigh muscles were activated simultaneously with the change in the joint angles and the displacement of CT, whereas the ankle muscles were activated later than the thigh muscles, especially the muscle tibialis anterior, showing some adaptations in consecutive attempts. At the ankle strategy the EMG amplitude was greatest in thigh muscles, reproducing contour of changes in joint angles, whereas the ankle muscles were activated only slightly during changes of joint angles. In the case of hip strategy dominated the EMG amplitude of the muscle tibialis anterior, which was activated when driving down the trunk and fixation of the joint angles that was accompanied by a slight coactivation of the calf muscles with the step-like increase in the amplitude of the EMG of the thigh muscles. Choice of leg muscles to start the squatting on both strategies occurred without a definite pattern, which may indicate the existence of a wide range of options for muscle activity in a single strategy.

  1. A Force-Velocity Relationship and Coordination Patterns in Overarm Throwing

    PubMed Central

    van den Tillaar, Roland; Ettema, Gertjan

    2004-01-01

    A force-velocity relationship in overarm throwing was determined using ball weights varying from 0.2 to 0.8 kg. Seven experienced handball players were filmed at 240 frames per second. Velocity of joints of the upper extremity and ball together with the force on the ball were derived from the data. A statistically significant negative relationship between force and maximal ball velocity, as well as between ball weight and maximal ball velocity was observed. Also, with increase of ball weight the total throwing movement time increased. No significant change in relative timing of the different joints was demonstrated, suggesting that the subjects did not change their “global ”coordination pattern (kinematics) within the tested range of ball weights. A simple model revealed that 67% of ball velocity at ball release was explained by the summation of effects from the velocity of elbow extension and internal rotation of the shoulder. With regard to the upper extremity the internal rotation of the shoulder and elbow extension are two important contributors to the total ball velocity at release. Key Points An inverse relationship between load and velocity and a linear force-velocity exists in overarm throwing with ball weights varying from 0.2 to 0.8 kg. Qualitatively, no changes in coordination pattern (relative timing) occur with increasing ball weight within the tested range of ball weights. The absolute throwing movement time increased with ball weight. Quantitatively, with regard to the upper extremity, the internal rotation of the shoulder and elbow extension are two important contributors to the total ball velocity at release. PMID:24624005

  2. Classification of the intention to generate a shoulder versus elbow torque by means of a time frequency synthesized spatial patterns BCI algorithm

    NASA Astrophysics Data System (ADS)

    Deng, Jie; Yao, Jun; Dewald, Julius P. A.

    2005-12-01

    In this paper, we attempt to determine a subject's intention of generating torque at the shoulder or elbow, two neighboring joints, using scalp electroencephalogram signals from 163 electrodes for a brain-computer interface (BCI) application. To achieve this goal, we have applied a time-frequency synthesized spatial patterns (TFSP) BCI algorithm with a presorting procedure. Using this method, we were able to achieve an average recognition rate of 89% in four healthy subjects, which is comparable to the highest rates reported in the literature but now for tasks with much closer spatial representations on the motor cortex. This result demonstrates, for the first time, that the TFSP BCI method can be applied to separate intentions between generating static shoulder versus elbow torque. Furthermore, in this study, the potential application of this BCI algorithm for brain-injured patients was tested in one chronic hemiparetic stroke subject. A recognition rate of 76% was obtained, suggesting that this BCI method can provide a potential control signal for neural prostheses or other movement coordination improving devices for patients following brain injury.

  3. [Correlation analysis on the disorders of patella-femoral joint and torsional deformity of tibia].

    PubMed

    Sun, Zhen-Jie; Yuan, Yi; Liu, Rui-Bo

    2015-03-01

    To reveal the possible mechanism involved in patella-femoral degenerative arthritis (PFDA) in- duced by torsion-deformity of tibia via analyzing the relationship between torsion-deformity of the tibia in patients with PFDA and the disorder of patella-femoral joint under the static and dynamic conditions. From October 2009 to October 2010, 50 patients (86 knees, 24 knees of male patients and 62 knees of female patients) with PFDA were classified as disease group and 16 people (23 knees, 7 knees of males and 16 knees of females) in the control group. The follow indexes were measured: the torsion-angle of tibia on CT scanning imagings, the patella-femoral congruence angle and lateral patella-femoral angle under static and dynamic conditions when the knee bent at 30 degrees of flexion. Based on the measurement results, the relationship between the torsion-deformity of tibias and the disorders of patella-femoral joints in patients with PFDA were analyzed. Finally,the patients were divided into three groups including large torsion-angle group, small torsion-angle group and normal group according to the size of torsion-angle, in order to analyze the relationship between torsion-deformity and disorders of patella-femoral joint, especially under the dynamic conditions. Compared with patients without PFDA, the ones with PFDA had bigger torsion-angle (30.30 ± 7.11)° of tibia, larger patella-femoral congruence angle (13.20 ± 3.94)° and smaller lateral patella-femoral angle (12.30 ± 3.04)°. The congruence angle and lateral patella-femoral angle under static and dynamic conditions had statistical differences respectively in both too-big torsion-angle group and too-small torsion-angle group. The congruence angle and lateral patella-femoral angle under static and dynamic conditions had no statistical differences in normal torsion-angle group. Torsion-deformity of tibia is the main reason for disorder of patella-femoral joint in the patients with PFDA. Torsion-deformity of tibia is always accompanied by instability of patella-femoral joint,especially under the dynamic condition, thus causing PFDA. It can not only provide arrangement information and degenerative condition of patella-femoral joint,but also provide guidance through the analysis on the relationship for better clinical prevention and early treatment of degenerative bone and joint disease.

  4. Ontogenetic scaling of fore limb and hind limb joint posture and limb bone cross-sectional geometry in vervets and baboons.

    PubMed

    Burgess, M Loring; Schmitt, Daniel; Zeininger, Angel; McFarlin, Shannon C; Zihlman, Adrienne L; Polk, John D; Ruff, Christopher B

    2016-09-01

    Previous studies suggest that the postures habitually adopted by an animal influence the mechanical loading of its long bones. Relatively extended limb postures in larger animals should preferentially reduce anteroposterior (A-P) relative to mediolateral (M-L) bending of the limb bones and therefore decrease A-P/M-L rigidity. We test this hypothesis by examining growth-related changes in limb bone structure in two primate taxa that differ in ontogenetic patterns of joint posture. Knee and elbow angles of adult and immature vervets (Chlorocebus aethiops, n = 16) were compared to published data for baboons (Papio hamadryas ursinus, n = 33, Patel et al., ). Ontogenetic changes in ratios of A-P/M-L bending rigidity in the femur and humerus were compared in skeletal samples (C. aethiops, n = 28; P. cynocephalus, n = 39). Size changes were assessed with linear regression, and age group differences tested with ANOVA. Only the knee of baboons shows significant postural change, becoming more extended with age and mass. A-P/M-L bending rigidity of the femur decreases during ontogeny in immature and adult female baboons only. Trends in the humerus are less marked. Adult male baboons have higher A-P/M-L bending rigidity of the femur than females. The hypothesized relationship between more extended joints and reduced A-P/M-L bending rigidity is supported by our results for immature and adult female baboon hind limbs, and the lack of significant age changes in either parameter in forelimbs and vervets. Adult males of both species depart from general ontogenetic trends, possibly due to socially mediated behavioral differences between sexes. Am J Phys Anthropol 161:72-83, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Imaging of Kingella kingae musculoskeletal infections in children: a series of 5 cases.

    PubMed

    Nguyen, Jie C; Rebsamen, Susan L; Tuite, Michael J; Davis, J Muse; Rosas, Humberto G

    2018-06-16

    Kingella kingae musculoskeletal infections continue to be under-diagnosed and there remains a paucity of literature on its imaging features. The purpose of this manuscript is to review the imaging, clinical, and laboratory findings of microbiology-proven K. kingae infections. A retrospective review of musculoskeletal infections between January 1, 2013 and Dec 31, 2016 yielded 134 patients from whom 5 patients had confirmed K. kingae infections (3 boys and 2 girls, mean age of 16 months, range 9-38 months). Picture archiving and communication system and electronic medical records were reviewed. At presentation, none of the patients had a fever and not all patients had abnormal inflammatory markers. Three patients had septic arthritis (2 knee and 1 sternomanubrial joints), one had epiphyseal osteomyelitis, and one had lumbar spondylodiscitis. The case of epiphyseal osteomyelitis of the distal humerus also had elbow joint involvement. A combination of radiography (n = 4), ultrasound (n = 2), and magnetic resonance (MR) imaging (n = 5) were performed. Prominent synovial thickening was observed for both knee and elbow joints and extensive regional myositis for all except for the patient with sternomanubrial joint infection. The diagnosis of K. kingae infection resulted in a change in the antibiotic regimen in 80% of the patients. Disproportionate synovial thickening, prominent peri-articular myositis, and/or characteristic sites of involvement demonstrating imaging features of infection or inflammation in a young child with mild infectious symptoms and elevated inflammatory markers should invoke the possibility of an underlying K. kingae infection.

  6. Modified Denavit-Hartenberg parameters for better location of joint axis systems in robot arms

    NASA Technical Reports Server (NTRS)

    Barker, L. K.

    1986-01-01

    The Denavit-Hartenberg parameters define the relative location of successive joint axis systems in a robot arm. A recent justifiable criticism is that one of these parameters becomes extremely large when two successive joints have near-parallel rotational axes. Geometrically, this parameter then locates a joint axis system at an excessive distance from the robot arm and, computationally, leads to an ill-conditioned transformation matrix. In this paper, a simple modification (which results from constraining a transverse vector between successive joint rotational axes to be normal to one of the rotational axes, instead of both) overcomes this criticism and favorably locates the joint axis system. An example is given for near-parallel rotational axes of the elbow and shoulder joints in a robot arm. The regular and modified parameters are extracted by an algebraic method with simulated measurement data. Unlike the modified parameters, extracted values of the regular parameters are very sensitive to measurement accuracy.

  7. Objective evaluation of female feet and leg joint conformation at time of selection and post first parity in swine.

    PubMed

    Stock, J D; Calderón Díaz, J A; Rothschild, M F; Mote, B E; Stalder, K J

    2018-06-09

    Feet and legs of replacement females were objectively evaluated at selection, i.e. approximately 150 days of age (n=319) and post first parity, i.e. any time after weaning of first litter and before 2nd parturition (n=277) to 1) compare feet and leg joint angle ranges between selection and post first parity; 2) identify feet and leg joint angle differences between selection and first three weeks of second gestation; 3) identify feet and leg join angle differences between farms and gestation days during second gestation; and 4) obtain genetic variance components for conformation angles for the two time points measured. Angles for carpal joint (knee), metacarpophalangeal joint (front pastern), metatarsophalangeal joint (rear pastern), tarsal joint (hock), and rear stance were measured using image analysis software. Between selection and post first parity significant differences were observed for all joints measured (P < 0.05). Knee, front and rear pastern angles were less (more flexion), and hock angles were greater (less flexion) as age progressed (P < 0.05), while the rear stance pattern was less (feet further under center) at selection than post first parity (only including measures during first three weeks of second gestation). Only using post first parity leg conformation information, farm was a significant source of variation for front and rear pasterns and rear stance angle measurements (P < 0.05). Knee angle was less (more flexion) (P < 0.05) as gestation age progressed. Heritability estimates were low to moderate (0.04 - 0.35) for all traits measured across time points. Genetic correlations between the same joints at different time points were high (> 0.8) between the front leg joints and low (<0.2) between the rear leg joints. High genetic correlations between time points indicate that the trait can be considered the same at either time point, and low genetic correlations indicate that the trait at different time points should be considered as two separate traits. Minimal change in the front leg suggests conformation traits that remain between selection and post first parity, while larger changes in rear leg indicate that rear leg conformation traits should be evaluated at multiple time periods.

  8. Structural analysis of three space crane articulated-truss joint concepts

    NASA Technical Reports Server (NTRS)

    Wu, K. Chauncey; Sutter, Thomas R.

    1992-01-01

    Three space crane articulated truss joint concepts are studied to evaluate their static structural performance over a range of geometric design parameters. Emphasis is placed on maintaining the four longeron reference truss performance across the joint while allowing large angle articulation. A maximum positive articulation angle and the actuator length ratio required to reach the angle are computed for each concept as the design parameters are varied. Configurations with a maximum articulation angle less than 120 degrees or actuators requiring a length ratio over two are not considered. Tip rotation and lateral deflection of a truss beam with an articulated truss joint at the midspan are used to select a point design for each concept. Deflections for one point design are up to 40 percent higher than for the other two designs. Dynamic performance of the three point design is computed as a function of joint articulation angle. The two lowest frequencies of each point design are relatively insensitive to large variations in joint articulation angle. One point design has a higher maximum tip velocity for the emergency stop than the other designs.

  9. Effects of tibial plateau angle and spacer thickness applied during in vitro canine total knee replacement on three-dimensional kinematics and collateral ligament strain.

    PubMed

    Baker, Katherine M; Foutz, Timothy L; Johnsen, Kyle J; Budsberg, Steven C

    2014-09-01

    To quantify the 3-D kinematics and collateral ligament strain of stifle joints in cadaveric canine limbs before and after cranial cruciate ligament transection followed by total knee replacement (TKR) involving various tibial plateau angles and spacer thicknesses. 6 hemi-pelvises collected from clinically normal nonchondrodystrophic dogs (weight range, 25 to 35 kg). Hemi-pelvises were mounted on a modified Oxford knee rig that allowed 6 degrees of freedom of the stifle joint but prevented mechanical movement of the hip and tarsal joints. Kinematics and collateral ligament strain were measured continuously while stifle joints were flexed. Data were again collected after cranial cruciate ligament transection and TKR with combinations of 3 plateau angles (0°, 4°, and 8°) and spacer thicknesses (5, 7, and 9 mm). Presurgical (ie, normal) stifle joint rotations were comparable to those previously documented for live dogs. After TKR, kinematics recorded for the 8°, 5-mm implant most closely resembled those of unaltered stifle joints. Decreasing the plateau angle and increasing spacer thickness altered stifle joint adduction, internal rotation, and medial translation. Medial collateral ligament strain was minimal in unaltered stifle joints and was unaffected by TKR. Lateral collateral ligament strain decreased with steeper plateau angles but returned to a presurgical level at the flattest plateau angle. Among the constructs tested, greatest normalization of canine stifle joint kinematics in vitro was achieved with the steepest plateau angle paired with the thinnest spacer. Furthermore, results indicated that strain to the collateral ligaments was not negatively affected by TKR.

  10. Correlation between hindfoot joint three-dimensional kinematics and the changes of the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot.

    PubMed

    Zhang, Yi-Jun; Xu, Jian; Wang, Yue; Lin, Xiang-Jin; Ma, Xin

    2015-02-01

    The aim of this study was to explore the correlation between the kinematics of the hindfoot joint and the medial arch angle change in stage II posterior tibial tendon dysfunction flatfoot three-dimensionally under loading. Computed tomography (CT) scans of 12 healthy feet and 12 feet with stage II posterior tibial tendon dysfunction flatfoot were taken both in non- and full-body-weight-bearing condition. The CT images of the hindfoot bones were reconstructed into three-dimensional models with Mimics and Geomagic reverse engineering software. The three-dimensional changes of the hindfoot joint were calculated to determine their correlation to the medial longitudinal arch angle. The medial arch angle change was larger in stage II posterior tibial tendon dysfunction flatfoot compared to that in healthy foot under loading. The rotation and translation of the talocalcaneal joint, the talonavicular joint and the calcanocuboid joint had little influence on the change of the medial arch angle in healthy foot. However, the eversion of the talocalcaneal joint, the proximal translation of the calcaneus relative to the talus and the dorsiflexion of talonavicular joint could increase the medial arch angle in stage II posterior tibial tendon dysfunction flatfoot under loading. Joint instability occurred in patients with stage II posterior tibial tendon dysfunction flatfoot under loading. Limitation of over movement of the talocalcaneal joint and the talonavicular joint may help correct the medial longitudinal arch in stage II posterior tibial tendon dysfunction flatfoot. Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. KSC-05pd2466

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, a crane lifts the remote manipulator system boom out of Atlantis’ payload bay. The boom will be temporarily stored. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  12. KSC-05pd2467

    NASA Image and Video Library

    2005-11-07

    KENNEDY SPACE CENTER, FLA. - In the Orbiter Processing Facility Bay 1 at NASA Kennedy Space Center, the remote manipulator system boom is lifted away from Atlantis’ payload bay and will be temporarily stored. The RMS includes the electromechanical arm that maneuvers a payload from the payload bay of the orbiter to its deployment position and then releases it. It can also grapple a free-flying payload, maneuver it to the payload bay of the orbiter and berth it in the orbiter. The RMS arm is 50 feet 3 inches long and 15 inches in diameter. It weighs 905 pounds, and the total system weighs 994 pounds. The RMS has six joints that correspond roughly to the joints of the human arm, with shoulder yaw and pitch joints; an elbow pitch joint; and wrist pitch, yaw and roll joints. The end effector is the unit at the end of the wrist that actually grabs, or grapples, the payload.

  13. Pseudoelastic Nitinol-Based Device for Relaxation of Spastic Elbow in Stroke Patients

    NASA Astrophysics Data System (ADS)

    Viscuso, S.; Pittaccio, S.; Caimmi, M.; Gasperini, G.; Pirovano, S.; Villa, E.; Besseghini, S.; Molteni, F.

    2009-08-01

    A compliant brace (EDGES) promoting spastic elbow relaxation was designed to investigate the potentialities of pseudoelastic NiTi in orthotics. By exploiting its peculiar characteristics, EDGES could improve elbow posture without constraining movements and thus avoiding any pain to the patient. A commercial Ni50.7-Ti49.3 alloy heat treated at 400 °C 1 h + WQ was selected for this application. A prototype of EDGES was assembled with two thermoplastic shells connected by polycentric hinges. Four 2-mm-diameter NiTi bars were encastred in the upper-arm shell and let slide along tubular fixtures on the forearm. Specially designed bending tests demonstrated suitable moment-angle characteristics. Two post-stroke subjects (aged 62 and 64, mild elbow flexors spasticity) wore EDGES for 1 week, at least 10 h a day. No additional treatment was applied during this period or the following week. A great improvement (20° ± 5°) of the resting position was observed in both patients as early as 3 h after starting the treatment. Acceptability was very good. A slight decrease in spasticity was also observed in both subjects. All the effects disappeared 1 week after discontinuation. EDGES appears to be a good alternative to traditional orthoses in terms of acceptability and effectiveness in improving posture, especially whenever short-term splinting is planned.

  14. Comparative analyses of genetic trends and prospects for selection against hip and elbow dysplasia in 15 UK dog breeds

    PubMed Central

    2013-01-01

    Background Hip dysplasia remains one of the most serious hereditary diseases occurring in dogs despite long-standing evaluation schemes designed to aid selection for healthy joints. Many researchers have recommended the use of estimated breeding values (EBV) to improve the rate of genetic progress from selection against hip and elbow dysplasia (another common developmental orthopaedic disorder), but few have empirically quantified the benefits of their use. This study aimed to both determine recent genetic trends in hip and elbow dysplasia, and evaluate the potential improvements in response to selection that publication of EBV for such diseases would provide, across a wide range of pure-bred dog breeds. Results The genetic trend with respect to hip and elbow condition due to phenotypic selection had improved in all breeds, except the Siberian Husky. However, derived selection intensities are extremely weak, equivalent to excluding less than a maximum of 18% of the highest risk animals from breeding. EBV for hip and elbow score were predicted to be on average between 1.16 and 1.34 times more accurate than selection on individual or both parental phenotypes. Additionally, compared to the proportion of juvenile animals with both parental phenotypes, the proportion with EBV of a greater accuracy than selection on such phenotypes increased by up to 3-fold for hip score and up to 13-fold for elbow score. Conclusions EBV are shown to be both more accurate and abundant than phenotype, providing more reliable information on the genetic risk of disease for a greater proportion of the population. Because the accuracy of selection is directly related to genetic progress, use of EBV can be expected to benefit selection for the improvement of canine health and welfare. Public availability of EBV for hip score for the fifteen breeds included in this study will provide information on the genetic risk of disease in nearly a third of all dogs annually registered by the UK Kennel Club, with in excess of a quarter having an EBV for elbow score as well. PMID:23452300

  15. Comparative analyses of genetic trends and prospects for selection against hip and elbow dysplasia in 15 UK dog breeds.

    PubMed

    Lewis, Thomas W; Blott, Sarah C; Woolliams, John A

    2013-03-02

    Hip dysplasia remains one of the most serious hereditary diseases occurring in dogs despite long-standing evaluation schemes designed to aid selection for healthy joints. Many researchers have recommended the use of estimated breeding values (EBV) to improve the rate of genetic progress from selection against hip and elbow dysplasia (another common developmental orthopaedic disorder), but few have empirically quantified the benefits of their use. This study aimed to both determine recent genetic trends in hip and elbow dysplasia, and evaluate the potential improvements in response to selection that publication of EBV for such diseases would provide, across a wide range of pure-bred dog breeds. The genetic trend with respect to hip and elbow condition due to phenotypic selection had improved in all breeds, except the Siberian Husky. However, derived selection intensities are extremely weak, equivalent to excluding less than a maximum of 18% of the highest risk animals from breeding. EBV for hip and elbow score were predicted to be on average between 1.16 and 1.34 times more accurate than selection on individual or both parental phenotypes. Additionally, compared to the proportion of juvenile animals with both parental phenotypes, the proportion with EBV of a greater accuracy than selection on such phenotypes increased by up to 3-fold for hip score and up to 13-fold for elbow score. EBV are shown to be both more accurate and abundant than phenotype, providing more reliable information on the genetic risk of disease for a greater proportion of the population. Because the accuracy of selection is directly related to genetic progress, use of EBV can be expected to benefit selection for the improvement of canine health and welfare. Public availability of EBV for hip score for the fifteen breeds included in this study will provide information on the genetic risk of disease in nearly a third of all dogs annually registered by the UK Kennel Club, with in excess of a quarter having an EBV for elbow score as well.

  16. Assessing Arthroscopic Skills Using Wireless Elbow-Worn Motion Sensors.

    PubMed

    Kirby, Georgina S J; Guyver, Paul; Strickland, Louise; Alvand, Abtin; Yang, Guang-Zhong; Hargrove, Caroline; Lo, Benny P L; Rees, Jonathan L

    2015-07-01

    Assessment of surgical skill is a critical component of surgical training. Approaches to assessment remain predominantly subjective, although more objective measures such as Global Rating Scales are in use. This study aimed to validate the use of elbow-worn, wireless, miniaturized motion sensors to assess the technical skill of trainees performing arthroscopic procedures in a simulated environment. Thirty participants were divided into three groups on the basis of their surgical experience: novices (n = 15), intermediates (n = 10), and experts (n = 5). All participants performed three standardized tasks on an arthroscopic virtual reality simulator while wearing wireless wrist and elbow motion sensors. Video output was recorded and a validated Global Rating Scale was used to assess performance; dexterity metrics were recorded from the simulator. Finally, live motion data were recorded via Bluetooth from the wireless wrist and elbow motion sensors and custom algorithms produced an arthroscopic performance score. Construct validity was demonstrated for all tasks, with Global Rating Scale scores and virtual reality output metrics showing significant differences between novices, intermediates, and experts (p < 0.001). The correlation of the virtual reality path length to the number of hand movements calculated from the wireless sensors was very high (p < 0.001). A comparison of the arthroscopic performance score levels with virtual reality output metrics also showed highly significant differences (p < 0.01). Comparisons of the arthroscopic performance score levels with the Global Rating Scale scores showed strong and highly significant correlations (p < 0.001) for both sensor locations, but those of the elbow-worn sensors were stronger and more significant (p < 0.001) than those of the wrist-worn sensors. A new wireless assessment of surgical performance system for objective assessment of surgical skills has proven valid for assessing arthroscopic skills. The elbow-worn sensors were shown to achieve an accurate assessment of surgical dexterity and performance. The validation of an entirely objective assessment of arthroscopic skill with wireless elbow-worn motion sensors introduces, for the first time, a feasible assessment system for the live operating theater with the added potential to be applied to other surgical and interventional specialties. Copyright © 2015 by The Journal of Bone and Joint Surgery, Incorporated.

  17. The Shank-to-Vertical-Angle as a parameter to evaluate tuning of Ankle-Foot Orthoses.

    PubMed

    Kerkum, Yvette L; Houdijk, Han; Brehm, Merel-Anne; Buizer, Annemieke I; Kessels, Manon L C; Sterk, Arjan; van den Noort, Josien C; Harlaar, Jaap

    2015-09-01

    The effectiveness of an Ankle-Foot Orthosis footwear combination (AFO-FC) may be partly dependent on the alignment of the ground reaction force with respect to lower limb joint rotation centers, reflected by joint angles and moments. Adjusting (i.e. tuning) the AFO-FC's properties could affect this alignment, which may be guided by monitoring the Shank-to-Vertical-Angle. This study aimed to investigate whether the Shank-to-Vertical-Angle during walking responds to variations in heel height and footplate stiffness, and if this would reflect changes in joint angles and net moments in healthy adults. Ten subjects walked on an instrumented treadmill and performed six trials while walking with bilateral rigid Ankle-Foot Orthoses. The AFO-FC heel height was increased, aiming to impose a Shank-to-Vertical-Angle of 5°, 11° and 20°, and combined with a flexible or stiff footplate. For each trial, the Shank-to-Vertical-Angle, joint flexion-extension angles and net joint moments of the right leg at midstance were averaged over 25 gait cycles. The Shank-to-Vertical-Angle significantly increased with increasing heel height (p<0.001), resulting in an increase in knee flexion angle and internal knee extensor moment (p<0.001). The stiff footplate reduced the effect of heel height on the internal knee extensor moment (p=0.030), while the internal ankle plantar flexion moment increased (p=0.035). Effects of heel height and footplate stiffness on the hip joint were limited. Our results support the potential to use the Shank-to-Vertical-Angle as a parameter to evaluate AFO-FC tuning, as it is responsive to changes in heel height and reflects concomitant changes in the lower limb angles and moments. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. BATMAV: a 2-DOF bio-inspired flapping flight platform

    NASA Astrophysics Data System (ADS)

    Bunget, Gheorghe; Seelecke, Stefan

    2010-04-01

    Due to the availability of small sensors, Micro-Aerial Vehicles (MAVs) can be used for detection missions of biological, chemical and nuclear agents. Traditionally these devices used fixed or rotary wings, actuated with electric DC motortransmission, a system which brings the disadvantage of a heavier platform. The overall objective of the BATMAV project is to develop a biologically inspired bat-like MAV with flexible and foldable wings for flapping flight. This paper presents a flight platform that features bat-inspired wings which are able to actively fold their elbow joints. A previous analysis of the flight physics for small birds, bats and large insects, revealed that the mammalian flight anatomy represents a suitable flight platform that can be actuated efficiently using Shape Memory Alloy (SMA) artificial-muscles. A previous study of the flight styles in bats based on the data collected by Norberg [1] helped to identify the required joint angles as relevant degrees of freedom for wing actuation. Using the engineering theory of robotic manipulators, engineering kinematic models of wings with 2 and 3-DOFs were designed to mimic the wing trajectories of the natural flier Plecotus auritus. Solid models of the bat-like skeleton were designed based on the linear and angular dimensions resulted from the kinematic models. This structure of the flight platform was fabricated using rapid prototyping technologies and assembled to form a desktop prototype with 2-DOFs wings. Preliminary flapping test showed suitable trajectories for wrist and wingtip that mimic the flapping cycle of the natural flyer.

  19. Application of a symbolic motion structure representation algorithm to identify upper extremity kinematic changes during a repetitive task.

    PubMed

    Whittaker, Rachel L; Park, Woojin; Dickerson, Clark R

    2018-04-27

    Efficient and holistic identification of fatigue-induced movement strategies can be limited by large between-subject variability in descriptors of joint angle data. One promising alternative to traditional, or computationally intensive methods is the symbolic motion structure representation algorithm (SMSR), which identifies the basic spatial-temporal structure of joint angle data using string descriptors of temporal joint angle trajectories. This study attempted to use the SMSR to identify changes in upper extremity time series joint angle data during a repetitive goal directed task causing muscle fatigue. Twenty-eight participants (15 M, 13 F) performed a seated repetitive task until fatigued. Upper extremity joint angles were extracted from motion capture for representative task cycles. SMSRs, averages and ranges of several joint angles were compared at the start and end of the repetitive task to identify kinematic changes with fatigue. At the group level, significant increases in the range of all joint angle data existed with large between-subject variability that posed a challenge to the interpretation of these fatigue-related changes. However, changes in the SMSRs across participants effectively summarized the adoption of adaptive movement strategies. This establishes SMSR as a viable, logical, and sensitive method of fatigue identification via kinematic changes, with novel application and pragmatism for visual assessment of fatigue development. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Improving Kinematic Accuracy of Soft Wearable Data Gloves by Optimizing Sensor Locations

    PubMed Central

    Kim, Dong Hyun; Lee, Sang Wook; Park, Hyung-Soon

    2016-01-01

    Bending sensors enable compact, wearable designs when used for measuring hand configurations in data gloves. While existing data gloves can accurately measure angular displacement of the finger and distal thumb joints, accurate measurement of thumb carpometacarpal (CMC) joint movements remains challenging due to crosstalk between the multi-sensor outputs required to measure the degrees of freedom (DOF). To properly measure CMC-joint configurations, sensor locations that minimize sensor crosstalk must be identified. This paper presents a novel approach to identifying optimal sensor locations. Three-dimensional hand surface data from ten subjects was collected in multiple thumb postures with varied CMC-joint flexion and abduction angles. For each posture, scanned CMC-joint contours were used to estimate CMC-joint flexion and abduction angles by varying the positions and orientations of two bending sensors. Optimal sensor locations were estimated by the least squares method, which minimized the difference between the true CMC-joint angles and the joint angle estimates. Finally, the resultant optimal sensor locations were experimentally validated. Placing sensors at the optimal locations, CMC-joint angle measurement accuracies improved (flexion, 2.8° ± 1.9°; abduction, 1.9° ± 1.2°). The proposed method for improving the accuracy of the sensing system can be extended to other types of soft wearable measurement devices. PMID:27240364

Top