A complete electrical shock hazard classification system and its application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gordon, Lloyd; Cartelli, Laura; Graham, Nicole
Current electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. As a result, this leaves a substantial gap in the management of electrical hazards in Research and Development (R&D) and specialized high voltage and high power equipment. We find substantial use of direct current (dc) electrical energy, and the use of capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50/60 Hz power. This paper proposes a method of classifying allmore » of the electrical shock hazards found in all types of R&D and utilization equipment. Examples of the variation of these hazards from NFPA 70E include (a) high voltage can be harmless, if the available current is sufficiently low, (b) low voltage can be harmful if the available current/power is high, (c) high voltage capacitor hazards are unique and include severe reflex action, affects on the heart, and tissue damage, and (d) arc flash hazard analysis for dc and capacitor systems are not provided in existing standards. This work has led to a comprehensive electrical hazard classification system that is based on various research conducted over the past 100 years, on analysis of such systems in R&D, and on decades of experience. Lastly, the new comprehensive electrical shock hazard classification system uses a combination of voltage, shock current available, fault current available, power, energy, and waveform to classify all forms of electrical hazards.« less
A complete electrical shock hazard classification system and its application
Gordon, Lloyd; Cartelli, Laura; Graham, Nicole
2018-02-08
Current electrical safety standards evolved to address the hazards of 60-Hz power that are faced primarily by electricians, linemen, and others performing facility and utility work. As a result, this leaves a substantial gap in the management of electrical hazards in Research and Development (R&D) and specialized high voltage and high power equipment. We find substantial use of direct current (dc) electrical energy, and the use of capacitors, inductors, batteries, and radiofrequency (RF) power. The electrical hazards of these forms of electricity and their systems are different than for 50/60 Hz power. This paper proposes a method of classifying allmore » of the electrical shock hazards found in all types of R&D and utilization equipment. Examples of the variation of these hazards from NFPA 70E include (a) high voltage can be harmless, if the available current is sufficiently low, (b) low voltage can be harmful if the available current/power is high, (c) high voltage capacitor hazards are unique and include severe reflex action, affects on the heart, and tissue damage, and (d) arc flash hazard analysis for dc and capacitor systems are not provided in existing standards. This work has led to a comprehensive electrical hazard classification system that is based on various research conducted over the past 100 years, on analysis of such systems in R&D, and on decades of experience. Lastly, the new comprehensive electrical shock hazard classification system uses a combination of voltage, shock current available, fault current available, power, energy, and waveform to classify all forms of electrical hazards.« less
30 CFR 250.114 - How must I install and operate electrical equipment?
Code of Federal Regulations, 2010 CFR
2010-07-01
.... (a) You must classify all areas according to API RP 500, Recommended Practice for Classification of... Division 2, or API RP 505, Recommended Practice for Classification of Locations for Electrical... and hazards of electrical equipment. (c) You must install all electrical systems according to API RP...
Code of Federal Regulations, 2014 CFR
2014-10-01
... HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous... cargoes. (a) This section applies to locations surrounding the storage and handling of combustible liquid... hazardous locations in § 111.106-9 of this subpart apply. ...
NASA Astrophysics Data System (ADS)
Brinovar, Iztok; Srpčič, Gregor; Seme, Sebastijan; Štumberger, Bojan; Hadžiselimović, Miralem
2017-07-01
This article deals with the classification of explosion-proof protected induction motors, which are used in hazardous areas, into adequate temperature and efficiency class. Hazardous areas are defined as locations with a potentially explosive atmosphere where explosion may occur due to present of flammable gasses, liquids or combustible dusts (industrial plants, mines, etc.). Electric motors and electrical equipment used in such locations must be specially designed and tested to prevent electrical initiation of explosion due to high surface temperature and arcing contacts. This article presents the basic tests of three-phase explosion-proof protected induction motor with special emphasis on the measuring system and temperature rise test. All the measurements were performed with high-accuracy instrumentation and accessory equipment and carried out at the Institute of energy technology in the Electric machines and drives laboratory and Applied electrical engineering laboratory.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-22
... System of Classification and Labelling of Chemicals (UNSCEGHS) AGENCY: Pipeline and Hazardous Materials... the Globally Harmonized System of Classification and Labelling of Chemicals (UNSCEGHS) to be held July... UNSCOE TDG meeting include: Explosives and related matters Listing, classification and packing Electric...
30 CFR 250.1628 - Design, installation, and operation of production systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Systems; (3) Electrical system information including a plan of each platform deck, outlining all hazardous... Electrical Installations at Petroleum Facilities Classified as Class I, Division 1 and Division 2, or API RP 505, Recommended Practice for Classification of Locations for Electrical Installations at Petroleum...
46 CFR 110.10-1 - Incorporation by reference.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Classing Mobile Offshore Drilling Units, Part 4 Machinery and Systems, 2001 (“ABS MODU Rules”), IBR... Hazardous (Classified) Locations: Type of Protection—Encapsulation “m”, approved July 31, 2009 (“ANSI/ISA... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2013 CFR
2013-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2011 CFR
2011-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2012 CFR
2012-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2014 CFR
2014-01-01
... (Continued) RURAL UTILITIES SERVICE, DEPARTMENT OF AGRICULTURE ELECTRIC ENGINEERING, ARCHITECTURAL SERVICES... appendix is U.S. Army Corps of Engineers Engineering and Design Dam Safety Assurance Program, ER 1110-2... human habitation) Uncertain (rural location with few residences and only transient or industrial...
16 CFR 1500.85 - Exemptions from classification as banned hazardous substances.
Code of Federal Regulations, 2012 CFR
2012-01-01
... operation of miniature engines for model airplanes, boats, cars, etc. (6) Novelties consisting of a mixture...: (i) Are designed to be ignited by electrical means. (ii) Contain no more than 62.5 grams (2.2 ounces... cars, and similar models, provided such solid fuel pellets: (i) Weigh not more than 11.5 grams each...
16 CFR 1500.85 - Exemptions from classification as banned hazardous substances.
Code of Federal Regulations, 2010 CFR
2010-01-01
... operation of miniature engines for model airplanes, boats, cars, etc. (6) Novelties consisting of a mixture...: (i) Are designed to be ignited by electrical means. (ii) Contain no more than 62.5 grams (2.2 ounces... cars, and similar models, provided such solid fuel pellets: (i) Weigh not more than 11.5 grams each...
Flow diagram analysis of electrical fatalities in construction industry.
Chi, Chia-Fen; Lin, Yuan-Yuan; Ikhwan, Mohamad
2012-01-01
The current study reanalyzed 250 electrical fatalities in the construction industry from 1996 to 2002 into seven patterns based on source of electricity (power line, energized equipment, improperly installed or damaged equipment), direct contact or indirect contact through some source of injury (boom vehicle, metal bar or pipe, and other conductive material). Each fatality was coded in terms of age, company size, experience, performing tasks, source of injury, accident cause and hazard pattern. The Chi-square Automatic Interaction Detector (CHAID) was applied to the coded data of the fatal electrocution to find a subset of predictors that might derive meaningful classifications or accidents scenarios. A series of Flow Diagrams was constructed based on CHAID result to illustrate the flow of electricity travelling from electrical source to human body. Each of the flow diagrams can be directly linked with feasible prevention strategies by cutting the flow of electricity.
49 CFR 173.2a - Classification of a material having more than one hazard.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 2 2010-10-01 2010-10-01 false Classification of a material having more than one... SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS General § 173.2a Classification of a material having more than one hazard. (a) Classification of a material having more than one hazard. Except as...
42 CFR 84.52 - Respiratory hazards; classification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 42 Public Health 1 2012-10-01 2012-10-01 false Respiratory hazards; classification. 84.52 Section... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Classification of Approved Respirators; Scope of Approval; Atmospheric Hazards; Service Time § 84.52 Respiratory...
42 CFR 84.52 - Respiratory hazards; classification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 42 Public Health 1 2014-10-01 2014-10-01 false Respiratory hazards; classification. 84.52 Section... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Classification of Approved Respirators; Scope of Approval; Atmospheric Hazards; Service Time § 84.52 Respiratory...
42 CFR 84.52 - Respiratory hazards; classification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 42 Public Health 1 2010-10-01 2010-10-01 false Respiratory hazards; classification. 84.52 Section... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Classification of Approved Respirators; Scope of Approval; Atmospheric Hazards; Service Time § 84.52 Respiratory...
42 CFR 84.52 - Respiratory hazards; classification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 42 Public Health 1 2013-10-01 2013-10-01 false Respiratory hazards; classification. 84.52 Section... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Classification of Approved Respirators; Scope of Approval; Atmospheric Hazards; Service Time § 84.52 Respiratory...
42 CFR 84.52 - Respiratory hazards; classification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 42 Public Health 1 2011-10-01 2011-10-01 false Respiratory hazards; classification. 84.52 Section... SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Classification of Approved Respirators; Scope of Approval; Atmospheric Hazards; Service Time § 84.52 Respiratory...
21 CFR 7.41 - Health hazard evaluation and recall classification.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Health hazard evaluation and recall classification. 7.41 Section 7.41 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN..., and Industry Responsibilities § 7.41 Health hazard evaluation and recall classification. (a) An...
NASA Technical Reports Server (NTRS)
1971-01-01
The findings, conclusions, and recommendations relative to the investigations conducted to evaluate tests for classifying pyrotechnic materials and end items as to their hazard potential are presented. Information required to establish an applicable means of determining the potential hazards of pyrotechnics is described. Hazard evaluations are based on the peak overpressure or impulse resulting from the explosion as a function of distance from the source. Other hazard classification tests include dust ignition sensitivity, impact ignition sensitivity, spark ignition sensitivity, and differential thermal analysis.
Screening tests for hazard classification of complex waste materials - Selection of methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Weltens, R., E-mail: reinhilde.weltens@vito.be; Vanermen, G.; Tirez, K.
In this study we describe the development of an alternative methodology for hazard characterization of waste materials. Such an alternative methodology for hazard assessment of complex waste materials is urgently needed, because the lack of a validated instrument leads to arbitrary hazard classification of such complex waste materials. False classification can lead to human and environmental health risks and also has important financial consequences for the waste owner. The Hazardous Waste Directive (HWD) describes the methodology for hazard classification of waste materials. For mirror entries the HWD classification is based upon the hazardous properties (H1-15) of the waste which canmore » be assessed from the hazardous properties of individual identified waste compounds or - if not all compounds are identified - from test results of hazard assessment tests performed on the waste material itself. For the latter the HWD recommends toxicity tests that were initially designed for risk assessment of chemicals in consumer products (pharmaceuticals, cosmetics, biocides, food, etc.). These tests (often using mammals) are not designed nor suitable for the hazard characterization of waste materials. With the present study we want to contribute to the development of an alternative and transparent test strategy for hazard assessment of complex wastes that is in line with the HWD principles for waste classification. It is necessary to cope with this important shortcoming in hazardous waste classification and to demonstrate that alternative methods are available that can be used for hazard assessment of waste materials. Next, by describing the pros and cons of the available methods, and by identifying the needs for additional or further development of test methods, we hope to stimulate research efforts and development in this direction. In this paper we describe promising techniques and argument on the test selection for the pilot study that we have performed on different types of waste materials. Test results are presented in a second paper. As the application of many of the proposed test methods is new in the field of waste management, the principles of the tests are described. The selected tests tackle important hazardous properties but refinement of the test battery is needed to fulfil the a priori conditions.« less
MC3196 Detonator Shipping Package Hazard Classification Assessment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones; Robert B.
1979-05-31
An investigation was made to determine whether the MC3196 detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosives per 49 CFR 173.113. This study covers the Propagation Test and the External Heat Test as approved by DOE Albuquerque Operations Office. Test data led to the recommeded hazard classification of detonating fuze, Class C explosives.
Assessment of the MC3608 detonator shipping package hazard classification
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, R.B.
1981-08-07
An investigation was made to determine whether the MC 3608 Detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosive, per 49 CFR 173.113. This study covers the propagation test as approved by DOE-Albuquerque Operations Office. Analysis of the test data led to the recommended hazard classification of Detonating Fuze, Class C Explosive.
Development of Subscale Fast Cookoff Test (PREPRINT)
2006-09-21
The hazards classification procedures have been harmonized with both the UN Test and Criteria Manual for UN Series 1...aimed at the development of a sub-scale alternate test protocol to the external fire test currently required for final hazards classification (HC...external fire test currently required for final hazards classification (HC) of an ordnance system. The specific goal of this part of the task was
Di Mare, Valerio; Garramone, Gaetano; Rubbiani, Maristella; Moretto, Angelo
2017-02-15
Hazard classification of chemicals can be defined as a logic-mathematical operation aimed at identifying the type and severity of the inherent hazards of a substance or a mixture. The purpose of this study was to evaluate, in 134 safety data sheets (SDSs): i) the hazard classification and ii) its coherence with sections 9 (physical-chemical properties), 11 (toxicological properties) and 12 (ecological properties) of the SDSs. Hazard classification and the information provided in sections 9, 11 and 12 of the SDSs have been evaluated against the criteria provided in annexes VI of the Dangerous Substance Directive, II and III of the Dangerous Preparations Directive, I and VI of the Regulation (EC) n. 1272/2008. Most of the analyzed SDSs of substances (62%) was associated to non-classified chemicals (61.4%), although 19.6% of them should have been classified. By contrast, 59.4% of classified substances (representing 38.6% of analyzed ones) were wrongly classified. Fifty-four %, 54% and 67% of suggested substances hazard classification were in line with sections 9 (physical-chemical properties), 11 (toxicological properties) and 12 (ecological properties). The proportion of hazard classification mistakes in SDS was significant, suggesting the need of more qualified experts to derive classification. The introduction of an ad hoc evaluation team, managed by a single, qualified specialist, could represent a solution to ensure the needed improvement of SDSs quality.
Inayat-Hussain, Salmaan H; Fukumura, Masao; Muiz Aziz, A; Jin, Chai Meng; Jin, Low Wei; Garcia-Milian, Rolando; Vasiliou, Vasilis; Deziel, Nicole C
2018-08-01
Recent trends have witnessed the global growth of unconventional oil and gas (UOG) production. Epidemiologic studies have suggested associations between proximity to UOG operations with increased adverse birth outcomes and cancer, though specific potential etiologic agents have not yet been identified. To perform effective risk assessment of chemicals used in UOG production, the first step of hazard identification followed by prioritization specifically for reproductive toxicity, carcinogenicity and mutagenicity is crucial in an evidence-based risk assessment approach. To date, there is no single hazard classification list based on the United Nations Globally Harmonized System (GHS), with countries applying the GHS standards to generate their own chemical hazard classification lists. A current challenge for chemical prioritization, particularly for a multi-national industry, is inconsistent hazard classification which may result in misjudgment of the potential public health risks. We present a novel approach for hazard identification followed by prioritization of reproductive toxicants found in UOG operations using publicly available regulatory databases. GHS classification for reproductive toxicity of 157 UOG-related chemicals identified as potential reproductive or developmental toxicants in a previous publication was assessed using eleven governmental regulatory agency databases. If there was discordance in classifications across agencies, the most stringent classification was assigned. Chemicals in the category of known or presumed human reproductive toxicants were further evaluated for carcinogenicity and germ cell mutagenicity based on government classifications. A scoring system was utilized to assign numerical values for reproductive health, cancer and germ cell mutation hazard endpoints. Using a Cytoscape analysis, both qualitative and quantitative results were presented visually to readily identify high priority UOG chemicals with evidence of multiple adverse effects. We observed substantial inconsistencies in classification among the 11 databases. By adopting the most stringent classification within and across countries, 43 chemicals were classified as known or presumed human reproductive toxicants (GHS Category 1), while 31 chemicals were classified as suspected human reproductive toxicants (GHS Category 2). The 43 reproductive toxicants were further subjected to analysis for carcinogenic and mutagenic properties. Calculated hazard scores and Cytoscape visualization yielded several high priority chemicals including potassium dichromate, cadmium, benzene and ethylene oxide. Our findings reveal diverging GHS classification outcomes for UOG chemicals across regulatory agencies. Adoption of the most stringent classification with application of hazard scores provides a useful approach to prioritize reproductive toxicants in UOG and other industries for exposure assessments and selection of safer alternatives. Copyright © 2018 Elsevier Ltd. All rights reserved.
de Groot, Ronald; Brekelmans, Pieter; Herremans, Joke; Meulenbelt, Jan
2010-01-01
The United Nations Globally Harmonized System of Classification and Labelling of Chemicals (UN-GHS) is developed to harmonize the criteria for hazard communication worldwide. The European Regulation on classification, labeling, and packaging of substances and mixtures [CLP Regulation (European Commission, EC) No 1272/2008] will align the existing European Union (EU) legislation to the UN-GHS. This CLP Regulation entered into force on January 20, 2009, and will, after a transitional period, replace the current rules on classification, labeling, and packaging for supply and use in Europe. Both old and new classifications will exist simultaneously until 2010 for substances and until 2015 for mixtures. The new hazard classification will introduce new health hazard classes and categories, with associated new hazard pictograms, signal words, Hazard (H)-statements, and Precautionary (P)-statements as labeling elements. Furthermore, the CLP Regulation will affect the notification of product information on hazardous products to poisons information centers (PICs). At this moment product notification widely varies in procedures and requirements across EU Member States. Article 45 of the CLP Regulation contains a provision stating that the EC will (by January 20, 2012) review the possibility of harmonizing product notification. The European Association of Poisons Centres and Clinical Toxicologists (EAPCCT) is recognized as an important stakeholder. For cosmetic products, the new Cosmetics Regulation will directly implement a new procedure for electronic cosmetic product notification in all EU Member States. Both the CLP Regulation and the Cosmetics Regulation will develop their own product notification procedure within different time frames. Harmonization of notification procedures for both product groups, especially a common electronic format, would be most effective from a cost-benefit viewpoint and would be welcomed by PICs.
Hazard classification assessment for the MC3423 detonator shipping package
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jones, R.B.
1981-11-05
An investigation was made to determine whether the MC3423 detonator should be assigned a DOT hazard classification of Detonating Fuze, Class C Explosive, per Federal Register 49 CFR 173.113, when packaged as specified. This study covers two propagation tests which evaluated the effects of two orientations of the MC3423 in its shipping tray. The method of testing was approved by DOE, Albuquerque Operations Office. Test data led to the recommended hazard classification of Detonating Fuze, Class C Explosive for both orientations of the detonator.
Semi-automated landform classification for hazard mapping of soil liquefaction by earthquake
NASA Astrophysics Data System (ADS)
Nakano, Takayuki
2018-05-01
Soil liquefaction damages were caused by huge earthquake in Japan, and the similar damages are concerned in near future huge earthquake. On the other hand, a preparation of soil liquefaction risk map (soil liquefaction hazard map) is impeded by the difficulty of evaluation of soil liquefaction risk. Generally, relative soil liquefaction risk should be able to be evaluated from landform classification data by using experimental rule based on the relationship between extent of soil liquefaction damage and landform classification items associated with past earthquake. Therefore, I rearranged the relationship between landform classification items and soil liquefaction risk intelligibly in order to enable the evaluation of soil liquefaction risk based on landform classification data appropriately and efficiently. And I developed a new method of generating landform classification data of 50-m grid size from existing landform classification data of 250-m grid size by using digital elevation model (DEM) data and multi-band satellite image data in order to evaluate soil liquefaction risk in detail spatially. It is expected that the products of this study contribute to efficient producing of soil liquefaction hazard map by local government.
Development of Hazards Classification Data on Propellants and Explosives
1978-11-01
scattering photometer. A near forward, dark field instrument called a Sinclair-Phoenix photometer is common- ly used for measuring a wide range of...hazardä classification pro- cedure for in-process materials, and 5) Experimental evaluation of selected small-scale tests for application in the hazards...responsible for the experimental por- tion of this work. In addition to the authors, other IITRI personnel who contributed to this program were R
46 CFR 169.662 - Hazardous locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Hazardous locations. 169.662 Section 169.662 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS SAILING SCHOOL VESSELS Machinery and Electrical Electrical § 169.662 Hazardous locations. Electrical equipment must not be...
NASA Astrophysics Data System (ADS)
Esteban, Pere; Beck, Christoph; Philipp, Andreas
2010-05-01
Using data associated with accidents or damages caused by snow avalanches over the eastern Pyrenees (Andorra and Catalonia) several atmospheric circulation type catalogues have been obtained. For this purpose, different circulation type classification methods based on Principal Component Analysis (T-mode and S-mode using the extreme scores) and on optimization procedures (Improved K-means and SANDRA) were applied . Considering the characteristics of the phenomena studied, not only single day circulation patterns were taken into account but also sequences of circulation types of varying length. Thus different classifications with different numbers of types and for different sequence lengths were obtained using the different classification methods. Simple between type variability, within type variability, and outlier detection procedures have been applied for selecting the best result concerning snow avalanches type classifications. Furthermore, days without occurrence of the hazards were also related to the avalanche centroids using pattern-correlations, facilitating the calculation of the anomalies between hazardous and no hazardous days, and also frequencies of occurrence of hazardous events for each circulation type. Finally, the catalogues statistically considered the best results are evaluated using the avalanche forecaster expert knowledge. Consistent explanation of snow avalanches occurrence by means of circulation sequences is obtained, but always considering results from classifications with different sequence length. This work has been developed in the framework of the COST Action 733 (Harmonisation and Applications of Weather Type Classifications for European regions).
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-26
...; Hazards caused by electromagnetic interference and electrostatic discharge hazards; and Hearing loss. FDA... electromagnetic Electromagnetic compatibility. interference and electrostatic discharge hazards. Labeling. Hearing...
Manned spacecraft electrical fire safety
NASA Technical Reports Server (NTRS)
Wardell, A. W.
1971-01-01
The fire hazards created in spacecraft compartments by malfunction of electrical wiring are described. The tests for electrical wire/cable current overload flammability are presented. The application of electrical and material technologies to the reduction of fire hazards in spacecraft are examined.
Yang, Yu; Jiang, Yong-Hai; Lian, Xin-Ying; Xi, Bei-Dou; Ma, Zhi-Fei; Xu, Xiang-Jian; An, Da
2016-12-01
Hazardous waste landfill sites are a significant source of groundwater pollution. To ensure that these landfills with a significantly high risk of groundwater contamination are properly managed, a risk-based ranking method related to groundwater contamination is needed. In this research, a risk-based prioritization method for the classification of groundwater pollution from hazardous waste landfills was established. The method encompasses five phases, including risk pre-screening, indicator selection, characterization, classification and, lastly, validation. In the risk ranking index system employed here, 14 indicators involving hazardous waste landfills and migration in the vadose zone as well as aquifer were selected. The boundary of each indicator was determined by K-means cluster analysis and the weight of each indicator was calculated by principal component analysis. These methods were applied to 37 hazardous waste landfills in China. The result showed that the risk for groundwater contamination from hazardous waste landfills could be ranked into three classes from low to high risk. In all, 62.2 % of the hazardous waste landfill sites were classified in the low and medium risk classes. The process simulation method and standardized anomalies were used to validate the result of risk ranking; the results were consistent with the simulated results related to the characteristics of contamination. The risk ranking method was feasible, valid and can provide reference data related to risk management for groundwater contamination at hazardous waste landfill sites.
Zeng, Wenfeng; Tan, Qiang; Wu, Shihua; Deng, Yingcong; Liu, Lifen; Wang, Zhi; Liu, Yimin
2015-12-01
To investigate the application of risk grading and classification for occupational hazards in risk management for a shipbuilding project. The risk management for this shipbuilding project was performed by a comprehensive application of MES evaluation, quality assessment of occupational health management, and risk grading and classification for occupational hazards, through the methods of occupational health survey, occupational health testing, and occupational health examinations. The results of MES evaluation showed that the risk of occupational hazards in this project was grade 3, which was considered as significant risk; Q value calculated by quality assessment of occupational health management was 0.52, which was considered to be unqualified; the comprehensive evaluation with these two methods showed that the integrated risk rating for this shipbuilding project was class D, and follow- up and rectification were needed with a focus on the improvement in health management. The application of MES evaluation and quality assessment of occupational health management in risk management for occupational hazards can achieve objective and reasonable conclusions and has good applicability.
Hazardous waste containment's primary objective is to isolate wastes deemed as hazardous from man and environmental systems of air, soil, and water. Hazardous wastes differ from other waste classifications due to their increased potential to cause human health effects or environ...
NASA Astrophysics Data System (ADS)
Bates, Matthew E.; Keisler, Jeffrey M.; Zussblatt, Niels P.; Plourde, Kenton J.; Wender, Ben A.; Linkov, Igor
2016-02-01
Risk research for nanomaterials is currently prioritized by means of expert workshops and other deliberative processes. However, analytical techniques that quantify and compare alternative research investments are increasingly recommended. Here, we apply value of information and portfolio decision analysis—methods commonly applied in financial and operations management—to prioritize risk research for multiwalled carbon nanotubes and nanoparticulate silver and titanium dioxide. We modify the widely accepted CB Nanotool hazard evaluation framework, which combines nano- and bulk-material properties into a hazard score, to operate probabilistically with uncertain inputs. Literature is reviewed to develop uncertain estimates for each input parameter, and a Monte Carlo simulation is applied to assess how different research strategies can improve hazard classification. The relative cost of each research experiment is elicited from experts, which enables identification of efficient research portfolios—combinations of experiments that lead to the greatest improvement in hazard classification at the lowest cost. Nanoparticle shape, diameter, solubility and surface reactivity were most frequently identified within efficient portfolios in our results.
Bates, Matthew E; Keisler, Jeffrey M; Zussblatt, Niels P; Plourde, Kenton J; Wender, Ben A; Linkov, Igor
2016-02-01
Risk research for nanomaterials is currently prioritized by means of expert workshops and other deliberative processes. However, analytical techniques that quantify and compare alternative research investments are increasingly recommended. Here, we apply value of information and portfolio decision analysis-methods commonly applied in financial and operations management-to prioritize risk research for multiwalled carbon nanotubes and nanoparticulate silver and titanium dioxide. We modify the widely accepted CB Nanotool hazard evaluation framework, which combines nano- and bulk-material properties into a hazard score, to operate probabilistically with uncertain inputs. Literature is reviewed to develop uncertain estimates for each input parameter, and a Monte Carlo simulation is applied to assess how different research strategies can improve hazard classification. The relative cost of each research experiment is elicited from experts, which enables identification of efficient research portfolios-combinations of experiments that lead to the greatest improvement in hazard classification at the lowest cost. Nanoparticle shape, diameter, solubility and surface reactivity were most frequently identified within efficient portfolios in our results.
The 1991 International Aerospace and Ground Conference on Lightning and Static Electricity, volume 1
NASA Technical Reports Server (NTRS)
1991-01-01
The proceedings of the 1991 International Aerospace and Ground Conference on Lightning and Static Electricity are reported. Some of the topics covered include: lightning, lightning suppression, aerospace vehicles, aircraft safety, flight safety, aviation meteorology, thunderstorms, atmospheric electricity, warning systems, weather forecasting, electromagnetic coupling, electrical measurement, electrostatics, aircraft hazards, flight hazards, meteorological parameters, cloud (meteorology), ground effect, electric currents, lightning equipment, electric fields, measuring instruments, electrical grounding, and aircraft instruments.
21 CFR 7.41 - Health hazard evaluation and recall classification.
Code of Federal Regulations, 2011 CFR
2011-04-01
... exposed to the product being considered, with particular attention paid to the hazard to those individuals....e., Class I, Class II, or Class III, to indicate the relative degree of health hazard of the product...
The development of the WHO Recommended Classification of Pesticides by Hazard*
Copplestone, J. F.
1988-01-01
The WHO Recommended Classification of Pesticides by Hazard, which was originally intended as a tool to aid international harmonization of pesticide registration, is already 13 years old. Over the years, it has been refined, and it is now accepted by many countries and international organizations. The story of its development illustrates well an international approach to problems as they have arisen. PMID:3264763
McClellan, Roger O; Hesterberg, Thomas W; Wall, John C
2012-07-01
Diesel engines, a special type of internal combustion engine, use heat of compression, rather than electric spark, to ignite hydrocarbon fuels injected into the combustion chamber. Diesel engines have high thermal efficiency and thus, high fuel efficiency. They are widely used in commerce prompting continuous improvement in diesel engines and fuels. Concern for health effects from exposure to diesel exhaust arose in the mid-1900s and stimulated development of emissions regulations and research to improve the technology and characterize potential health hazards. This included epidemiological, controlled human exposure, laboratory animal and mechanistic studies to evaluate potential hazards of whole diesel exhaust. The International Agency for Research on Cancer (1989) classified whole diesel exhaust as - "probably carcinogenic to humans". This classification stimulated even more stringent regulations for particulate matter that required further technological developments. These included improved engine control, improved fuel injection system, enhanced exhaust cooling, use of ultra low sulfur fuel, wall-flow high-efficiency exhaust particulate filters, exhaust catalysts, and crankcase ventilation filtration. The composition of New Technology Diesel Exhaust (NTDE) is qualitatively different and the concentrations of particulate constituents are more than 90% lower than for Traditional Diesel Exhaust (TDE). We recommend that future reviews of carcinogenic hazards of diesel exhaust evaluate NTDE separately from TDE. Copyright © 2012 Elsevier Inc. All rights reserved.
78 FR 69745 - Safety and Security Plans for Class 3 Hazardous Materials Transported by Rail
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-20
... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... Security Plans for Class 3 Hazardous Materials Transported by Rail AGENCY: Pipeline and Hazardous Materials... characterization, classification, and selection of a packing group for Class 3 materials, and the corresponding...
30 CFR 250.802 - Design, installation, and operation of surface production-safety systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Production Platform Piping Systems (as incorporated by reference in § 250.198). (4) Electrical system... classified according to API RP 500, Recommended Practice for Classification of Locations for Electrical..., Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities...
30 CFR 250.802 - Design, installation, and operation of surface production-safety systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Production Platform Piping Systems (as incorporated by reference in § 250.198). (4) Electrical system... classified according to API RP 500, Recommended Practice for Classification of Locations for Electrical..., Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities...
30 CFR 250.802 - Design, installation, and operation of surface production-safety systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Production Platform Piping Systems (as incorporated by reference in § 250.198). (4) Electrical system... classified according to API RP 500, Recommended Practice for Classification of Locations for Electrical..., Recommended Practice for Classification of Locations for Electrical Installations at Petroleum Facilities...
Kim, Kyung-Hee; Song, Dae-Jong; Yu, Myeong-Hyun; Park, Yuon-Shin; Noh, Hye-Ran; Kim, Hae-Joon; Choi, Jae-Wook
2013-07-16
This study was conducted to review the validity of the need for the application of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS) to household chemical products in Korea. The study also aimed to assess the severity of health and environmental hazards of household chemical products using the GHS. 135 products were classified as 'cleaning agents and polishing agents' and 98 products were classified as 'bleaches, disinfectants, and germicides.' The current status of carcinogenic classification of GHS and carcinogenicity was examined for 272 chemical substances contained in household chemical products by selecting the top 11 products for each of the product categories. In addition, the degree of toxicity was assessed through analysis of whether the standard of the Republic of Korea's regulations on household chemical products had been exceeded or not. According to GHS health and environmental hazards, "acute toxicity (oral)" was found to be the highest for two product groups, 'cleaning agents and polishing agents', and 'bleaches, disinfectants, and germicides' (result of classification of 233 household chemical products) at 37.8% and 52.0% respectively. In an analysis of carcinogenicity assuming a threshold of IARC 2B for the substances in household chemical products, we found 'cleaning agents and polishing agents' to contain 12 chemical substances and 'bleaches, disinfectants, and germicides' 11 chemical substances. Some of the household chemical products were found to have a high hazard level including acute toxicity and germ cell mutagenicity, carcinogenicity, and reproductive toxicity. Establishing a hazard information delivery system including the application of GHS to household chemical products in Korea is urgent as well.
2013-01-01
Objectives This study was conducted to review the validity of the need for the application of the Globally Harmonized System of Classification and Labeling of Chemicals (GHS) to household chemical products in Korea. The study also aimed to assess the severity of health and environmental hazards of household chemical products using the GHS. Methods 135 products were classified as ‘cleaning agents and polishing agents’ and 98 products were classified as ‘bleaches, disinfectants, and germicides.’ The current status of carcinogenic classification of GHS and carcinogenicity was examined for 272 chemical substances contained in household chemical products by selecting the top 11 products for each of the product categories. In addition, the degree of toxicity was assessed through analysis of whether the standard of the Republic of Korea’s regulations on household chemical products had been exceeded or not. Results According to GHS health and environmental hazards, “acute toxicity (oral)” was found to be the highest for two product groups, ‘cleaning agents and polishing agents’, and ‘bleaches, disinfectants, and germicides’ (result of classification of 233 household chemical products) at 37.8% and 52.0% respectively. In an analysis of carcinogenicity assuming a threshold of IARC 2B for the substances in household chemical products, we found ‘cleaning agents and polishing agents’ to contain 12 chemical substances and ‘bleaches, disinfectants, and germicides’ 11 chemical substances. Conclusion Some of the household chemical products were found to have a high hazard level including acute toxicity and germ cell mutagenicity, carcinogenicity, and reproductive toxicity. Establishing a hazard information delivery system including the application of GHS to household chemical products in Korea is urgent as well. PMID:24472347
Down to Earth with an electric hazard from space
Love, Jeffrey J.; Bedrosian, Paul A.; Schultz, Adam
2017-01-01
In reaching across traditional disciplinary boundaries, solid-Earth geophysicists and space physicists are forging new collaborations to map magnetic-storm hazards for electric-power grids. Future progress in evaluation storm time geoelectric hazards will come primarily through monitoring, surveys, and modeling of related data.
49 CFR 173.2a - Classification of a material having more than one hazard.
Code of Federal Regulations, 2014 CFR
2014-10-01
... explosives. 3 Denotes an impossible combination. 4 For pesticides only, where a material has the hazards of... 5.2 (organic peroxide) material that meets the definition of any other hazard class or division as...
49 CFR 173.2a - Classification of a material having more than one hazard.
Code of Federal Regulations, 2013 CFR
2013-10-01
... explosives. 3 Denotes an impossible combination. 4 For pesticides only, where a material has the hazards of... 5.2 (organic peroxide) material that meets the definition of any other hazard class or division as...
49 CFR 173.2a - Classification of a material having more than one hazard.
Code of Federal Regulations, 2012 CFR
2012-10-01
... explosives. 3 Denotes an impossible combination. 4 For pesticides only, where a material has the hazards of... 5.2 (organic peroxide) material that meets the definition of any other hazard class or division as...
49 CFR 173.2a - Classification of a material having more than one hazard.
Code of Federal Regulations, 2011 CFR
2011-10-01
... explosives. 3 Denotes an impossible combination. 4 For pesticides only, where a material has the hazards of... 5.2 (organic peroxide) material that meets the definition of any other hazard class or division as...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2013 CFR
2013-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2012 CFR
2012-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards..., if the lamp is designed and constructed to prevent the ignition of explosive mixtures of methane and...
78 FR 37760 - Electrical Equipment in Hazardous Locations
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-24
... floating facilities engaged in OCS activities, however, equipment could be installed in hazardous locations... composition and the extent of equipment replacement. The myriad types of MODUs and facilities operating on the.... USCG-2012-0850] RIN 1625-AC00 Electrical Equipment in Hazardous Locations AGENCY: Coast Guard, DHS...
Hennebert, Pierre; van der Sloot, Hans A; Rebischung, Flore; Weltens, Reinhilde; Geerts, Lieve; Hjelmar, Ole
2014-10-01
Hazard classification of waste is a necessity, but the hazard properties (named "H" and soon "HP") are still not all defined in a practical and operational manner at EU level. Following discussion of subsequent draft proposals from the Commission there is still no final decision. Methods to implement the proposals have recently been proposed: tests methods for physical risks, test batteries for aquatic and terrestrial ecotoxicity, an analytical package for exhaustive determination of organic substances and mineral elements, surrogate methods for the speciation of mineral elements in mineral substances in waste, and calculation methods for human toxicity and ecotoxicity with M factors. In this paper the different proposed methods have been applied to a large assortment of solid and liquid wastes (>100). Data for 45 wastes - documented with extensive chemical analysis and flammability test - were assessed in terms of the different HP criteria and results were compared to LoW for lack of an independent classification. For most waste streams the classification matches with the designation provided in the LoW. This indicates that the criteria used by LoW are similar to the HP limit values. This data set showed HP 14 'Ecotoxic chronic' is the most discriminating HP. All wastes classified as acute ecotoxic are also chronic ecotoxic and the assessment of acute ecotoxicity separately is therefore not needed. The high number of HP 14 classified wastes is due to the very low limit values when stringent M factors are applied to total concentrations (worst case method). With M factor set to 1 the classification method is not sufficiently discriminating between hazardous and non-hazardous materials. The second most frequent hazard is HP 7 'Carcinogenic'. The third most frequent hazard is HP 10 'Toxic for reproduction' and the fourth most frequent hazard is HP 4 "Irritant - skin irritation and eye damage". In a stepwise approach, it seems relevant to assess HP 14 first, then, if the waste is not classified as hazardous, to assess subsequently HP 7, HP 10 and HP 4, and then if still not classified as hazardous, to assess the remaining properties. The elements triggering the HP 14 classification in order of importance are Zn, Cu, Pb, Cr, Cd and Hg. Progress in the speciation of Zn and Cu is essential for HP 14. Organics were quantified by the proposed method (AFNOR XP X30-489) and need no speciation. Organics can contribute significantly to intrinsic toxicity in many waste materials, but they are only of minor importance for the assessment of HP 14 as the metal concentrations are the main HP 14 classifiers. Organic compounds are however responsible for other toxicological characteristics (hormone disturbance, genotoxicity, reprotoxicity…) and shall be taken into account when the waste is not HP 14 classified. Copyright © 2014 Elsevier Ltd. All rights reserved.
30 CFR 19.7 - Protection against explosion hazard.
Code of Federal Regulations, 2010 CFR
2010-07-01
..., EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.7 Protection against explosion hazard. Unless properly designed, electric cap lamps may present two sources of probable explosion hazards... of cap lamp batteries: 100 amperes for a 4-volt battery; 75 amperes for a 6-volt battery; 50 amperes...
Measurement and Modeling of Job Stress of Electric Overhead Traveling Crane Operators
Krishna, Obilisetty B.; Maiti, Jhareswar; Ray, Pradip K.; Samanta, Biswajit; Mandal, Saptarshi; Sarkar, Sobhan
2015-01-01
Background In this study, the measurement of job stress of electric overhead traveling crane operators and quantification of the effects of operator and workplace characteristics on job stress were assessed. Methods Job stress was measured on five subscales: employee empowerment, role overload, role ambiguity, rule violation, and job hazard. The characteristics of the operators that were studied were age, experience, body weight, and body height. The workplace characteristics considered were hours of exposure, cabin type, cabin feature, and crane height. The proposed methodology included administration of a questionnaire survey to 76 electric overhead traveling crane operators followed by analysis using analysis of variance and a classification and regression tree. Results The key findings were: (1) the five subscales can be used to measure job stress; (2) employee empowerment was the most significant factor followed by the role overload; (3) workplace characteristics contributed more towards job stress than operator's characteristics; and (4) of the workplace characteristics, crane height was the major contributor. Conclusion The issues related to crane height and cabin feature can be fixed by providing engineering or foolproof solutions than relying on interventions related to the demographic factors. PMID:26929839
The joint use of the tangential electric field and surface Laplacian in EEG classification.
Carvalhaes, C G; de Barros, J Acacio; Perreau-Guimaraes, M; Suppes, P
2014-01-01
We investigate the joint use of the tangential electric field (EF) and the surface Laplacian (SL) derivation as a method to improve the classification of EEG signals. We considered five classification tasks to test the validity of such approach. In all five tasks, the joint use of the components of the EF and the SL outperformed the scalar potential. The smallest effect occurred in the classification of a mental task, wherein the average classification rate was improved by 0.5 standard deviations. The largest effect was obtained in the classification of visual stimuli and corresponded to an improvement of 2.1 standard deviations.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-12
... Fewer Animals to Identify Chemical Eye Hazards: Revised Criteria Necessary to Maintain Equivalent Hazard... criteria using results from 3-animal tests that would provide eye hazard classification equivalent to... least 1 positive animal in a 3-animal test to identify eye hazards will provide the same or greater...
Spontaneously Combustible Solids -- A Literature Search
1975-05-01
Wasahizeon, D.* C. It. K(EY WORDS (Continue on reviers side It necesary and Identify by block number) Pyrophoric Materials Hazardous Materials...and Identify by block number) Existing information on spontaneously combustible solids including pyrophoric - air hazardous materials and water... pyrophoric -air hazardous and water reactive materials. All available hazard classification systems and test methods releting to spontaneous combustion have
Integrative Chemical-Biological Read-Across Approach for Chemical Hazard Classification
Low, Yen; Sedykh, Alexander; Fourches, Denis; Golbraikh, Alexander; Whelan, Maurice; Rusyn, Ivan; Tropsha, Alexander
2013-01-01
Traditional read-across approaches typically rely on the chemical similarity principle to predict chemical toxicity; however, the accuracy of such predictions is often inadequate due to the underlying complex mechanisms of toxicity. Here we report on the development of a hazard classification and visualization method that draws upon both chemical structural similarity and comparisons of biological responses to chemicals measured in multiple short-term assays (”biological” similarity). The Chemical-Biological Read-Across (CBRA) approach infers each compound's toxicity from those of both chemical and biological analogs whose similarities are determined by the Tanimoto coefficient. Classification accuracy of CBRA was compared to that of classical RA and other methods using chemical descriptors alone, or in combination with biological data. Different types of adverse effects (hepatotoxicity, hepatocarcinogenicity, mutagenicity, and acute lethality) were classified using several biological data types (gene expression profiling and cytotoxicity screening). CBRA-based hazard classification exhibited consistently high external classification accuracy and applicability to diverse chemicals. Transparency of the CBRA approach is aided by the use of radial plots that show the relative contribution of analogous chemical and biological neighbors. Identification of both chemical and biological features that give rise to the high accuracy of CBRA-based toxicity prediction facilitates mechanistic interpretation of the models. PMID:23848138
Doe, J E
2014-10-01
There is an issue in the EU classification of substances for carcinogenicity and for reproductive or developmental toxicity which has brought difficulties to those involved in the process. The issue lies in the inability of the classification system to distinguish between carcinogens and reproductive toxicants with different levels of concern. This has its origins in the early years of toxicology when it was thought that a relatively small number of chemicals would be either carcinogens or reproductive toxicants, but this has turned out not to be the case. This can cause problems in communicating to the users of chemicals, including the public, the nature of the hazard presented by chemicals. Processes have been developed within the classification system for setting specific concentration limits which assess the degree of hazard for carcinogens and reproductive toxicants as high, medium or low. However these categories are not otherwise used in classification. It is proposed that their wider use would bring the advantages of transparency, clarity of communication, certainty of the process and would allow chemicals with a high degree of hazard to be identified and managed in an appropriate way. Copyright © 2014. The Authors. Journal of Applied Toxicology Published by John Wiley & Sons Ltd.
40 CFR 260.30 - Non-waste determinations and variances from classification as a solid waste.
Code of Federal Regulations, 2010 CFR
2010-07-01
... from classification as a solid waste. 260.30 Section 260.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking Petitions § 260.30 Non-waste determinations and variances from classification as a solid waste. In...
40 CFR 260.30 - Non-waste determinations and variances from classification as a solid waste.
Code of Federal Regulations, 2011 CFR
2011-07-01
... from classification as a solid waste. 260.30 Section 260.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking Petitions § 260.30 Non-waste determinations and variances from classification as a solid waste. In...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lewis, F.A.
1983-10-01
In August 1980, the National Institute for Occupational Safety and Health (NIOSH) received a request from the International Brotherhood of Electrical Workers Local 1600 for a Health Hazard Evaluation at the Pennsylvania Power and Light Company's Martins Creek Steam Electric Station in Martins Creek, Pennsylvania. The union was concerned about potential health and explosion hazards to employees from coal dust in Units 1 and 2 and the coal field. Based on environmental studies conducted at the time of the survey, NIOSH has determined that a potential health hazard may have existed due to exposure to respirable coal dust and quartz.more » Recommendations were made to ensure that potential health and explosion hazards are avoided in the future.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
R. Camp
Over the past four years, the Electrical Safety Program at PPPL has evolved in addressing changing regulatory requirements and lessons learned from accident events, particularly in regards to arc flash hazards and implementing NFPA 70E requirements. This presentation will discuss PPPL's approaches to the areas of electrical hazards evaluation, both shock and arc flash; engineered solutions for hazards mitigation such as remote racking of medium voltage breakers, operational changes for hazards avoidance, targeted personnel training and hazard appropriate personal protective equipment. Practical solutions for nominal voltage identification and zero voltage checks for lockout/tagout will also be covered. Finally, we willmore » review the value of a comprehensive electrical drawing program, employee attitudes expressed as a personal safety work ethic, integrated safety management, and sustained management support for continuous safety improvement.« less
Firefighter safety and photovoltaic installations research project
NASA Astrophysics Data System (ADS)
Backstrom, Robert; Dini, Dave
2012-10-01
Under the United States Department of Homeland Security (DHS) Assistance to Fire Fighters grant, UL LLC examined fire service concerns of photovoltaic (PV) systems. These concerns included firefighter vulnerability to electrical and casualty hazards when mitigating a fire involving photovoltaic (PV) modules systems. Findings include: 1. The electric shock hazard due to application of water is dependent on voltage, water conductivity, distance and spray pattern of the suppression stream. 2. Outdoor weather exposure rated electrical enclosures are not resistant to water penetration by fire hose streams. 3. Firefighter's gloves and boots afford limited protection against electrical shock provided the insulating surface is intact and dry. 4. "Turning off" an array is not a simple matter of opening a disconnect switch. 5. Tarps offer varying degrees of effectiveness. 6. Fire equipment scene lighting and exposure fires may illuminate PV systems sufficiently to cause a lock-on hazard. 7. Severely damaged PV arrays are capable of producing hazardous conditions. 8. Damage to modules from tools may result in both electrical and fire hazards. 9. Severing of conductors in both metal and plastic conduit results in electrical and fire hazards. 10. Responding personnel must stay away from the roofline in the event of modules or sections of an array sliding off the roof. 11. Fires under an array but above the roof may breach roofing materials and decking allowing fire to propagate into the attic space. Several tactical considerations were developed utilizing the data from the experiments.
Front-Line Resilience Perspectives: The Electric Grid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Finster, M.; Phillips, J.; Wallace, K.
2016-11-01
This report seeks to summarize how states and local utility companies are approaching all-hazards resilience in planning, construction, operations, and maintenance of the electric system, as well as challenges faced when addressing all-hazards resilience.
Clark, Charles R; McKee, Richard H; Freeman, James J; Swick, Derek; Mahagaokar, Suneeta; Pigram, Glenda; Roberts, Linda G; Smulders, Chantal J; Beatty, Patrick W
2013-12-01
The process streams refined from petroleum crude oil for use in petroleum products are among those designated by USEPA as UVCB substances (unknown or variable composition, complex reaction products and biological materials). They are identified on global chemical inventories with unique Chemical Abstract Services (CAS) numbers and names. The chemical complexity of most petroleum substances presents challenges when evaluating their hazards and can result in differing evaluations due to the varying level of hazardous constituents and differences in national chemical control regulations. Global efforts to harmonize the identification of chemical hazards are aimed at promoting the use of consistent hazard evaluation criteria. This paper discusses a systematic approach for the health hazard evaluation of petroleum substances using chemical categories and the United Nations (UN) Globally Harmonized System (GHS) of classification and labeling. Also described are historical efforts to characterize the hazard of these substances and how they led to the development of categories, the identification of potentially hazardous constituents which should be considered, and a summary of the toxicology of the major petroleum product groups. The use of these categories can increase the utility of existing data, provide better informed hazard evaluations, and reduce the amount of animal testing required. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
46 CFR 151.10-1 - Barge hull classifications.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Barge hull classifications. 151.10-1 Section 151.10-1... CARRYING BULK LIQUID HAZARDOUS MATERIAL CARGOES Barge Hull Construction Requirements § 151.10-1 Barge hull classifications. (a) Each barge constructed or converted in conformance with this subpart shall be assigned a hull...
NASA Astrophysics Data System (ADS)
Cerrai, D.; Anagnostou, E. N.; Wanik, D. W.; Bhuiyan, M. A. E.; Zhang, X.; Yang, J.; Astitha, M.; Frediani, M. E.; Schwartz, C. S.; Pardakhti, M.
2016-12-01
The overwhelming majority of human activities need reliable electric power. Severe weather events can cause power outages, resulting in substantial economic losses and a temporary worsening of living conditions. Accurate prediction of these events and the communication of forecasted impacts to the affected utilities is necessary for efficient emergency preparedness and mitigation. The University of Connecticut Outage Prediction Model (OPM) uses regression tree models, high-resolution weather reanalysis and real-time weather forecasts (WRF and NCAR ensemble), airport station data, vegetation and electric grid characteristics and historical outage data to forecast the number and spatial distribution of outages in the power distribution grid located within dense vegetation. Recent OPM improvements consist of improved storm classification and addition of new predictive weather-related variables and are demonstrated using a leave-one-storm-out cross-validation based on 130 severe extratropical storms and two hurricanes (Sandy and Irene) in the Northeast US. We show that it is possible to predict the number of trouble spots causing outages in the electric grid with a median absolute percentage error as low as 27% for some storm types, and at most around 40%, in a scale that varies between four orders of magnitude, from few outages to tens of thousands. This outage information can be communicated to the electric utility to manage allocation of crews and equipment and minimize the recovery time for an upcoming storm hazard.
40 CFR 164.120 - Notification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS RULES OF PRACTICE... REGISTER, CANCELLATIONS OF REGISTRATIONS, CHANGES OF CLASSIFICATIONS, SUSPENSIONS OF REGISTRATIONS AND... imminent hazard during the time required for cancellation or change in classification proceedings, but that...
40 CFR 164.120 - Notification.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS RULES OF PRACTICE... REGISTER, CANCELLATIONS OF REGISTRATIONS, CHANGES OF CLASSIFICATIONS, SUSPENSIONS OF REGISTRATIONS AND... imminent hazard during the time required for cancellation or change in classification proceedings, but that...
NASA Astrophysics Data System (ADS)
Wood, N. J.; Jones, J.; Spielman, S.
2013-12-01
Near-field tsunami hazards are credible threats to many coastal communities throughout the world. Along the U.S. Pacific Northwest coast, low-lying areas could be inundated by a series of catastrophic tsunami waves that begin to arrive in a matter of minutes following a Cascadia subduction zone (CSZ) earthquake. This presentation summarizes analytical efforts to classify communities with similar characteristics of community vulnerability to tsunami hazards. This work builds on past State-focused inventories of community exposure to CSZ-related tsunami hazards in northern California, Oregon, and Washington. Attributes used in the classification, or cluster analysis, include demography of residents, spatial extent of the developed footprint based on mid-resolution land cover data, distribution of the local workforce, and the number and type of public venues, dependent-care facilities, and community-support businesses. Population distributions also are characterized by a function of travel time to safety, based on anisotropic, path-distance, geospatial modeling. We used an unsupervised-model-based clustering algorithm and a v-fold, cross-validation procedure (v=50) to identify the appropriate number of community types. We selected class solutions that provided the appropriate balance between parsimony and model fit. The goal of the vulnerability classification is to provide emergency managers with a general sense of the types of communities in tsunami hazard zones based on similar characteristics instead of only providing an exhaustive list of attributes for individual communities. This classification scheme can be then used to target and prioritize risk-reduction efforts that address common issues across multiple communities. The presentation will include a discussion of the utility of proposed place classifications to support regional preparedness and outreach efforts.
Koenecke, Christian; Göhring, Gudrun; de Wreede, Liesbeth C.; van Biezen, Anja; Scheid, Christof; Volin, Liisa; Maertens, Johan; Finke, Jürgen; Schaap, Nicolaas; Robin, Marie; Passweg, Jakob; Cornelissen, Jan; Beelen, Dietrich; Heuser, Michael; de Witte, Theo; Kröger, Nicolaus
2015-01-01
The aim of this study was to determine the impact of the revised 5-group International Prognostic Scoring System cytogenetic classification on outcome after allogeneic stem cell transplantation in patients with myelodysplastic syndromes or secondary acute myeloid leukemia who were reported to the European Society for Blood and Marrow Transplantation database. A total of 903 patients had sufficient cytogenetic information available at stem cell transplantation to be classified according to the 5-group classification. Poor and very poor risk according to this classification was an independent predictor of shorter relapse-free survival (hazard ratio 1.40 and 2.14), overall survival (hazard ratio 1.38 and 2.14), and significantly higher cumulative incidence of relapse (hazard ratio 1.64 and 2.76), compared to patients with very good, good or intermediate risk. When comparing the predictive performance of a series of Cox models both for relapse-free survival and for overall survival, a model with simplified 5-group cytogenetics (merging very good, good and intermediate cytogenetics) performed best. Furthermore, monosomal karyotype is an additional negative predictor for outcome within patients of the poor, but not the very poor risk group of the 5-group classification. The revised International Prognostic Scoring System cytogenetic classification allows patients with myelodysplastic syndromes to be separated into three groups with clearly different outcomes after stem cell transplantation. Poor and very poor risk cytogenetics were strong predictors of poor patient outcome. The new cytogenetic classification added value to prediction of patient outcome compared to prediction models using only traditional risk factors or the 3-group International Prognostic Scoring System cytogenetic classification. PMID:25552702
Integrating remote sensing and terrain data in forest fire modeling
NASA Astrophysics Data System (ADS)
Medler, Michael Johns
Forest fire policies are changing. Managers now face conflicting imperatives to re-establish pre-suppression fire regimes, while simultaneously preventing resource destruction. They must, therefore, understand the spatial patterns of fires. Geographers can facilitate this understanding by developing new techniques for mapping fire behavior. This dissertation develops such techniques for mapping recent fires and using these maps to calibrate models of potential fire hazards. In so doing, it features techniques that strive to address the inherent complexity of modeling the combinations of variables found in most ecological systems. Image processing techniques were used to stratify the elements of terrain, slope, elevation, and aspect. These stratification images were used to assure sample placement considered the role of terrain in fire behavior. Examination of multiple stratification images indicated samples were placed representatively across a controlled range of scales. The incorporation of terrain data also improved preliminary fire hazard classification accuracy by 40%, compared with remotely sensed data alone. A Kauth-Thomas transformation (KT) of pre-fire and post-fire Thematic Mapper (TM) remotely sensed data produced brightness, greenness, and wetness images. Image subtraction indicated fire induced change in brightness, greenness, and wetness. Field data guided a fuzzy classification of these change images. Because fuzzy classification can characterize a continuum of a phenomena where discrete classification may produce artificial borders, fuzzy classification was found to offer a range of fire severity information unavailable with discrete classification. These mapped fire patterns were used to calibrate a model of fire hazards for the entire mountain range. Pre-fire TM, and a digital elevation model produced a set of co-registered images. Training statistics were developed from 30 polygons associated with the previously mapped fire severity. Fuzzy classifications of potential burn patterns were produced from these images. Observed field data values were displayed over the hazard imagery to indicate the effectiveness of the model. Areas that burned without suppression during maximum fire severity are predicted best. Areas with widely spaced trees and grassy understory appear to be misrepresented, perhaps as a consequence of inaccuracies in the initial fire mapping.
Hazards on Hazards, Ensuring Spacecraft Safety While Sampling Asteroid Surface Materials
NASA Astrophysics Data System (ADS)
Johnson, C. A.; DellaGiustina, D. N.
2016-12-01
The near-Earth object Bennu is a carbonaceous asteroid that is a remnant from the earliest stages of the solar-system formation. It is also a potentially hazardous asteroid with a relatively high probability of impacting Earth late in the 22nd century. While the primary focus of the NASA funded OSIRIS-REx mission is the return of pristine organic material from the asteroid's surface, information about Bennu's physical and chemical properties gleaned throughout operations will be critical for a possible future impact mitigation mission. In order to ensure a regolith sample can be successfully acquired, the sample site and surrounding area must be thoroughly assessed for any potential hazards to the spacecraft. The OSIRIS-REx Image Processing Working Group has been tasked with generating global and site-specific hazard maps using mosaics and a trio of feature identification techniques. These techniques include expert-lead manual classification, internet-based amateur classification using the citizen science platform CosmoQuest, and automated classification using machine learning and computer vision tools. Because proximity operations around Bennu do not begin until the end of 2018, we have an opportunity to test the performance of our software on analogue surfaces of other asteroids from previous NASA and other space agencies missions. The entire pipeline from image processing and mosaicking to hazard identification, analysis and mapping will be performed on asteroids of varying size, shape and surface morphology. As a result, upon arrival at Bennu, we will have the software and processes in place to quickly and confidently produce the hazard maps needed to ensure the success of our mission.
Identifying urban infrastructure multi-hazard risk in developing country contexts
NASA Astrophysics Data System (ADS)
Taylor, Faith; Malamud, Bruce; Millington, James
2017-04-01
This work presents a method to coarsely zone urban areas into different infrastructure typologies, from which physical vulnerability to a range of natural hazards and multi-hazard interactions can be estimated, particularly for developing country contexts where access to data can be a challenge. This work builds upon techniques developed for urban micrometeorology for classifying 12 urban typologies (Stewart and Oke, 2011) using Landsat 8 30 m × 30 m remote sensing imagery (Betchel et al., 2015). For each of these 12 urban typologies, we develop general rules about the presence, type and level of service of 10 broad categories of infrastructure (including buildings, roads, electricity and water), which we refer to as 'urban textures'. We have developed and applied this technique to five urban areas varying in size and structure across Africa: Nairobi (Kenya); Karonga (Malawi); Mzuzu (Malawi); Ibadan (Nigeria) and Cape Town (South Africa). For each urban area, a training dataset of 10 samples of each of the 12 urban texture classes is digitised using Google Earth imagery. A random forest classification is performed using SAGA GIS, resulting in a map of different urban typologies for each city. Based on >1200 georeferenced field photographs and expert interviews for Karonga (Malawi) and Nairobi (Kenya), generally applicable rules about the presence, type and level of service of 12 infrastructure types (the 'urban texture') are developed for each urban typology. For each urban texture, we are broadly reviewing how each infrastructure might be physically impacted by 21 different natural hazards and hazard interactions. This can aid local stakeholders such as emergency responders and urban planners to systematically identify how the infrastructure in different parts of an urban area might be affected differently during a natural disaster event.
49 CFR 173.132 - Class 6, Division 6.1-Definitions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 173.132 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Definitions Classification, Packing Group Assignments and Exceptions...
49 CFR 173.132 - Class 6, Division 6.1-Definitions.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 173.132 Transportation Other Regulations Relating to Transportation PIPELINE AND HAZARDOUS MATERIALS SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HAZARDOUS MATERIALS REGULATIONS SHIPPERS-GENERAL REQUIREMENTS FOR SHIPMENTS AND PACKAGINGS Definitions Classification, Packing Group Assignments and Exceptions...
Effects of carbon fibers on consumer products
NASA Technical Reports Server (NTRS)
Wise, R. A.; Lovett, C. D.
1980-01-01
The potential effects of carbon fibers on consumer products such as dishwashers, microwave ovens, and smoke detectors were investigated. The investigation was divided into two categories to determine the potential faults and hazards that could occur if fibers should enter the electrical circuits of the selected appliances. The categories were a fault analysis and a hazard analysis. Hazards considered were fire, flood, physical harm, explosion, and electrical shock. Electrical shock was found to be a possible occurrence related to carbon fibers. Faults were considered to be any effect on the performance of an appliance which would result in complaint or require service action.
Terrain classification and land hazard mapping in Kalsi-Chakrata area (Garhwal Himalaya), India
NASA Astrophysics Data System (ADS)
Choubey, Vishnu D.; Litoria, Pradeep K.
Terrain classification and land system mapping of a part of the Garhwal Himalaya (India) have been used to provide a base map for land hazard evaluation, with special reference to landslides and other mass movements. The study was based on MSS images, aerial photographs and 1:50,000 scale maps, followed by detailed field-work. The area is composed of two groups of rocks: well exposed sedimentary Precambrian formations in the Himalayan Main Boundary Thrust Belt and the Tertiary molasse deposits of the Siwaliks. Major tectonic boundaries were taken as the natural boundaries of land systems. A physiographic terrain classification included slope category, forest cover, occurrence of landslides, seismicity and tectonic activity in the area.
Space Propulsion Hazards Analysis Manual (SPHAM). Volume 2. Appendices
1988-10-01
lb. RESTRICTIVE MARKINGS UNCLASSIFIED 2a. SECURITY CLASSIFICATION AUTHORITY 3 . DISTRIBUTION/AVAILABILITY OF REPORT Approved for public release...Volume I Chapter 2 - Requirementb and the Hazards Analysis Process .... Volume I Chapter 3 - Accident Scenarios...list of the hazardous materials that are discussed; 3 ) description of the failure scenarios; 4) type of post-accident environment that is discussed
RF number as a new index for assessing combustion hazard of flammable gases.
Kondo, Shigeo; Takahashi, Akifumi; Tokuhashi, Kazuaki; Sekiya, Akira
2002-08-05
A new index called RF number has been proposed for assessing the combustion hazard of all sorts of flammable gases and their mixtures. RF number represents the total expectancy of combustion hazard in terms of flammability limits and heat of combustion for each known and unknown compounds. The advantage of RF number over others such as R-index and F-number for classification of combustion hazard has been highlighted.
Alabama-Mississippi Coastal Classification Maps - Perdido Pass to Cat Island
Morton, Robert A.; Peterson, Russell L.
2005-01-01
The primary purpose of the USGS National Assessment of Coastal Change Project is to provide accurate representations of pre-storm ground conditions for areas that are designated high-priority because they have dense populations or valuable resources that are at risk from storm waves. Another purpose of the project is to develop a geomorphic (land feature) coastal classification that, with only minor modification, can be applied to most coastal regions in the United States. A Coastal Classification Map describing local geomorphic features is the first step toward determining the hazard vulnerability of an area. The Coastal Classification Maps of the National Assessment of Coastal Change Project present ground conditions such as beach width, dune elevations, overwash potential, and density of development. In order to complete a hazard vulnerability assessment, that information must be integrated with other information, such as prior storm impacts and beach stability. The Coastal Classification Maps provide much of the basic information for such an assessment and represent a critical component of a storm-impact forecasting capability. The map above shows the areas covered by this web site. Click on any of the location names or outlines to view the Coastal Classification Map for that area.
7 CFR 1794.31 - Classification.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 7 Agriculture 12 2013-01-01 2013-01-01 false Classification. 1794.31 Section 1794.31 Agriculture... Classification. (a) Electric and telecommunications programs. RUS will normally determine the proper environmental classification of projects based on its evaluation of the project description set forth in the...
7 CFR 1794.31 - Classification.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 7 Agriculture 12 2012-01-01 2012-01-01 false Classification. 1794.31 Section 1794.31 Agriculture... Classification. (a) Electric and telecommunications programs. RUS will normally determine the proper environmental classification of projects based on its evaluation of the project description set forth in the...
7 CFR 1794.31 - Classification.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 7 Agriculture 12 2014-01-01 2013-01-01 true Classification. 1794.31 Section 1794.31 Agriculture... Classification. (a) Electric and telecommunications programs. RUS will normally determine the proper environmental classification of projects based on its evaluation of the project description set forth in the...
7 CFR 1794.31 - Classification.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 7 Agriculture 12 2010-01-01 2010-01-01 false Classification. 1794.31 Section 1794.31 Agriculture... Classification. (a) Electric and telecommunications programs. RUS will normally determine the proper environmental classification of projects based on its evaluation of the project description set forth in the...
7 CFR 1794.31 - Classification.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 7 Agriculture 12 2011-01-01 2011-01-01 false Classification. 1794.31 Section 1794.31 Agriculture... Classification. (a) Electric and telecommunications programs. RUS will normally determine the proper environmental classification of projects based on its evaluation of the project description set forth in the...
Risk-informed radioactive waste classification and reclassification.
Croff, Allen G
2006-11-01
Radioactive waste classification systems have been developed to allow wastes having similar hazards to be grouped for purposes of storage, treatment, packaging, transportation, and/or disposal. As recommended in the National Council on Radiation Protection and Measurements' Report No. 139, Risk-Based Classification of Radioactive and Hazardous Chemical Wastes, a preferred classification system would be based primarily on the health risks to the public that arise from waste disposal and secondarily on other attributes such as the near-term practicalities of managing a waste, i.e., the waste classification system would be risk informed. The current U.S. radioactive waste classification system is not risk informed because key definitions--especially that of high-level waste--are based on the source of the waste instead of its inherent characteristics related to risk. A second important reason for concluding the existing U.S. radioactive waste classification system is not risk informed is there are no general principles or provisions for exempting materials from being classified as radioactive waste which would then allow management without regard to its radioactivity. This paper elaborates the current system for classifying and reclassifying radioactive wastes in the United States, analyzes the extent to which the system is risk informed and the ramifications of its not being so, and provides observations on potential future direction of efforts to address shortcomings in the U.S. radioactive waste classification system as of 2004.
Multi-label spacecraft electrical signal classification method based on DBN and random forest
Li, Ke; Yu, Nan; Li, Pengfei; Song, Shimin; Wu, Yalei; Li, Yang; Liu, Meng
2017-01-01
In spacecraft electrical signal characteristic data, there exists a large amount of data with high-dimensional features, a high computational complexity degree, and a low rate of identification problems, which causes great difficulty in fault diagnosis of spacecraft electronic load systems. This paper proposes a feature extraction method that is based on deep belief networks (DBN) and a classification method that is based on the random forest (RF) algorithm; The proposed algorithm mainly employs a multi-layer neural network to reduce the dimension of the original data, and then, classification is applied. Firstly, we use the method of wavelet denoising, which was used to pre-process the data. Secondly, the deep belief network is used to reduce the feature dimension and improve the rate of classification for the electrical characteristics data. Finally, we used the random forest algorithm to classify the data and comparing it with other algorithms. The experimental results show that compared with other algorithms, the proposed method shows excellent performance in terms of accuracy, computational efficiency, and stability in addressing spacecraft electrical signal data. PMID:28486479
Multi-label spacecraft electrical signal classification method based on DBN and random forest.
Li, Ke; Yu, Nan; Li, Pengfei; Song, Shimin; Wu, Yalei; Li, Yang; Liu, Meng
2017-01-01
In spacecraft electrical signal characteristic data, there exists a large amount of data with high-dimensional features, a high computational complexity degree, and a low rate of identification problems, which causes great difficulty in fault diagnosis of spacecraft electronic load systems. This paper proposes a feature extraction method that is based on deep belief networks (DBN) and a classification method that is based on the random forest (RF) algorithm; The proposed algorithm mainly employs a multi-layer neural network to reduce the dimension of the original data, and then, classification is applied. Firstly, we use the method of wavelet denoising, which was used to pre-process the data. Secondly, the deep belief network is used to reduce the feature dimension and improve the rate of classification for the electrical characteristics data. Finally, we used the random forest algorithm to classify the data and comparing it with other algorithms. The experimental results show that compared with other algorithms, the proposed method shows excellent performance in terms of accuracy, computational efficiency, and stability in addressing spacecraft electrical signal data.
Phytoremediation of Hazardous Wastes
1995-07-26
TITLE AND SUBTITLE Phytoremediation of Hazardous Wastes 6. AUTHOR(S) Steven C. McCutcheon, N. Lee Wolfe, Laura H. Carreria and Tse-Yuan Ou 5... phytoremediation (the use of plants to degrade hazardous contaminants) was developed. The new approach to phytoremediation involves rigorous pathway analyses...SUBJECT TERMS phytoremediation , nitroreductase, laccase enzymes, SERDP 15. NUMBER OF PAGES 8 16. PRICE CODE N/A 17. SECURITY CLASSIFICATION OF
NASA Technical Reports Server (NTRS)
Koller, A. M., Jr.; Hannum, J. A. E.
1983-01-01
The transportation hazard classification of Ammonium Perchlorate is discussed. A test program was completed and data were forwarded to retain a Class 5.1 designation (oxidizer) for AP which is shipped internationally. As a follow-on to the initial team effort to conduct AP tests existing data were examined and a matrix which catalogs test parameters and findings was compiled. A collection of test protocols is developed to standardize test methods for energetic materials of all types. The actions to date are summarized; the participating organizations and their roles as presently understood; specific findings on AP (matrix); and issues, lessons learned, and potential actions of particular interest to the propulsion community which may evolve as a result of future U.N. propellant transportation classification activities.
NASA Technical Reports Server (NTRS)
Pennington, D. F.; Man, T.; Persons, B.
1977-01-01
The DOT classification for transportation, the military classification for quantity distance, and hazard compatibility grouping used to regulate the transportation and storage of explosives are presented along with a discussion of tests used in determining sensitivity of propellants to an impact/shock environment in the absence of a large explosive donor. The safety procedures and requirements of a Scout launch vehicle, Western and Eastern Test Range, and the Minuteman, Delta, and Poseidon programs are reviewed and summarized. Requirements of the space transportation system safety program include safety reviews from the subsystem level to the completed payload. The Scout safety procedures will satisfy a portion of these requirements but additional procedures need to be implemented to comply with the safety requirements for Shuttle operation from the Eastern Test Range.
Code of Federal Regulations, 2010 CFR
2010-01-01
...; will not shatter, crack, or chip; is free of cracks, flash (ridges due to imperfect molding), and... paragraph from classification as a banned hazardous substance. (6) Caps (paper or plastic) described in...
Predictive Models of target organ and Systemic toxicities (BOSC)
The objective of this work is to predict the hazard classification and point of departure (PoD) of untested chemicals in repeat-dose animal testing studies. We used supervised machine learning to objectively evaluate the predictive accuracy of different classification and regress...
Electromagnetic Radiation Hazards Testing for Non-Ionizing Radio Frequency Transmitting Equipment
2012-12-19
Hazards of Electromagnetic Radiation to Ordnance (HERO), Personnel (HERP), and Fuel (HERF) protection guidance for intentional non-ionizing Radio...HERO Hazards of Electromagnetic Radiation to Ordnance HERP Hazards of Electromagnetic Radiation to Personnel IEEE Institute of Electrical and...Systems Command Technical Manual, Electromagnetic Radiation Hazards ( Hazards to Ordnance ), 1 July 2008.
40 CFR 257.13 - Deadline for making demonstrations.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-Hazardous Waste Disposal Units Location Restrictions § 257.13 Deadline for making demonstrations. Existing..., 1998, must not accept CESQG hazardous waste for disposal. Ground-Water Monitoring and Corrective Action ... WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards...
Inception point for embankment dam stepped spillways
USDA-ARS?s Scientific Manuscript database
Stepped spillways applied to embankment dams have become a common design practice with the rehabilitation of aging watershed dams, especially those experiencing a hazard classification change from low to high hazard. Previous research on stepped spillways focused on gravity dams where aerated flow ...
Initiating Event Analysis of a Lithium Fluoride Thorium Reactor
NASA Astrophysics Data System (ADS)
Geraci, Nicholas Charles
The primary purpose of this study is to perform an Initiating Event Analysis for a Lithium Fluoride Thorium Reactor (LFTR) as the first step of a Probabilistic Safety Assessment (PSA). The major objective of the research is to compile a list of key initiating events capable of resulting in failure of safety systems and release of radioactive material from the LFTR. Due to the complex interactions between engineering design, component reliability and human reliability, probabilistic safety assessments are most useful when the scope is limited to a single reactor plant. Thus, this thesis will study the LFTR design proposed by Flibe Energy. An October 2015 Electric Power Research Institute report on the Flibe Energy LFTR asked "what-if?" questions of subject matter experts and compiled a list of key hazards with the most significant consequences to the safety or integrity of the LFTR. The potential exists for unforeseen hazards to pose additional risk for the LFTR, but the scope of this thesis is limited to evaluation of those key hazards already identified by Flibe Energy. These key hazards are the starting point for the Initiating Event Analysis performed in this thesis. Engineering evaluation and technical study of the plant using a literature review and comparison to reference technology revealed four hazards with high potential to cause reactor core damage. To determine the initiating events resulting in realization of these four hazards, reference was made to previous PSAs and existing NRC and EPRI initiating event lists. Finally, fault tree and event tree analyses were conducted, completing the logical classification of initiating events. Results are qualitative as opposed to quantitative due to the early stages of system design descriptions and lack of operating experience or data for the LFTR. In summary, this thesis analyzes initiating events using previous research and inductive and deductive reasoning through traditional risk management techniques to arrive at a list of key initiating events that can be used to address vulnerabilities during the design phases of LFTR development.
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
46 CFR 194.20-19 - Piping and electrical requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS HANDLING, USE, AND CONTROL OF EXPLOSIVES AND OTHER HAZARDOUS MATERIALS Chemical Stores and/or... not be installed within or pass through a chemical storeroom except as required for the chemical... Subchapter J (Electrical Engineering) of this chapter for Class I, Division 1, Group C hazardous locations. ...
Li, Ke; Liu, Yi; Wang, Quanxin; Wu, Yalei; Song, Shimin; Sun, Yi; Liu, Tengchong; Wang, Jun; Li, Yang; Du, Shaoyi
2015-01-01
This paper proposes a novel multi-label classification method for resolving the spacecraft electrical characteristics problems which involve many unlabeled test data processing, high-dimensional features, long computing time and identification of slow rate. Firstly, both the fuzzy c-means (FCM) offline clustering and the principal component feature extraction algorithms are applied for the feature selection process. Secondly, the approximate weighted proximal support vector machine (WPSVM) online classification algorithms is used to reduce the feature dimension and further improve the rate of recognition for electrical characteristics spacecraft. Finally, the data capture contribution method by using thresholds is proposed to guarantee the validity and consistency of the data selection. The experimental results indicate that the method proposed can obtain better data features of the spacecraft electrical characteristics, improve the accuracy of identification and shorten the computing time effectively. PMID:26544549
30 CFR 46.11 - Site-specific hazard awareness training.
Code of Federal Regulations, 2011 CFR
2011-07-01
... environmental conditions, recognition and avoidance of hazards such as electrical and powered-haulage hazards, traffic patterns and control, and restricted areas; and warning and evacuation signals, evacuation and...
Electrical Arc Ignition Testing for Constellation Program
NASA Technical Reports Server (NTRS)
Sparks, Kyle; Gallus, Timothy; Smith, Sarah
2009-01-01
NASA Johnson Space Center (JSC) Materials and Processes Branch requested that NASA JSC White Sands Test Facility (WSTF) perform testing for the Constellation Program to evaluate the hazard of electrical arc ignition of materials that could be in close proximity to batteries. Specifically, WSTF was requested to perform wire-break electrical arc tests to determine the current threshold for ignition of generic cotton woven fabric samples with a fixed voltage of 3.7 V, a common voltage for hand-held electrical devices. The wire-break test was developed during a previous test program to evaluate the hazard of electrical arc ignition inside the Extravehicular Mobility Unit [1].
Animal Effects from Soviet Atmospheric Nuclear Tests
2008-03-01
given to (1) radiological skin injuries, (2) the hazard levels of inhalation, and (3) peroral penetration of radioactive materials. Classification of...wave front became the basic hazard factor. Thus, during the test of November 22, 1955, in the temporizing region located at a distance of 36 km from...disk were particularly hazardous . The analysis of experimental results testifies to the fact that eyeground bums (chorioretinal injuries) are most
SEE Design Guide and Requirements for Electrical Deadfacing
NASA Technical Reports Server (NTRS)
Berki, Joe M.; Sargent, Noel; Kauffman, W. (Technical Monitor)
2002-01-01
The purpose of this design guide is to present information for understanding and mitigating the potential hazards associated with de-mating and mating powered electrical connectors on space flight vehicles. The process of staging is a necessary function in the launching of space vehicles and in the deployment of satellites, and now in manned assembly of systems in space. During this electrical interconnection process, various environments may be encountered that warrant the restriction of the voltage and current present across the pins of an electrical connector prior to separation, mating, or in a static open non-mated configuration. This process is called deadfacing. These potentially hazardous environments encompass the obvious explosive fuel vapors and human shock hazard, to multiple Electro-Magnetic Interference (EMI) phenomena related to the rapid rate of change in current as well as exposure to Radio Frequency (RF) fields.
NASA Astrophysics Data System (ADS)
Sigman, John Brevard
Buried explosive hazards present a pressing problem worldwide. Millions of acres and thousands of sites are contaminated in the United States alone [1, 2]. There are three categories of explosive hazards: metallic, intermediate-electrical conducting (IEC), and non-conducting targets. Metallic target detection and classification by electromagnetic (EM) signature has been the subject of research for many years. Key to the success of this research is modern multi-static Electromagnetic Induction (EMI) sensors, which are able to measure the wideband EMI response from metallic buried targets. However, no hardware solutions exist which can characterize IEC and non-conducting targets. While high-conducting metallic targets exhibit a quadrature peak response for frequencies in a traditional EMI regime under 100 kHz, the response of intermediate-conducting objects manifests at higher frequencies, between 100 kHz and 15 MHz. In addition to high-quality electromagnetic sensor data and robust electromagnetic models, a classification procedure is required to discriminate Targets of Interest (TOI) from clutter. Currently, costly human experts are used for this task. This expense and effort can be spared by using statistical signal processing and machine learning. This thesis has two main parts. In the first part, we explore using the high frequency EMI (HFEMI) band (100 kHz-15 MHz) for detection of carbon fiber UXO, voids, and of materials with characteristics that may be associated with improvised explosive devices (IED). We constructed an HFEMI sensing instrument, and apply the techniques of metal detection to sensing in a band of frequencies which are the transition between the induction and radar bands. In this transition domain, physical considerations and technological issues arise that cannot be solved via the approaches used in either of the bracketing lower and higher frequency ranges. In the second half of this thesis, we present a procedure for automatic classification of UXO. For maximum generality, our algorithm is robust and can handle sparse training examples of multi-class data. This procedure uses an unsupervised starter, semi-supervised techniques to gather training data, and concludes with supervised learning until all TOI are found. Additionally, an inference method for estimating the number of remaining true positives from a partial Receiver Operating Characteristic (ROC) curve is presented and applied to live-site dig histories.
NASA Astrophysics Data System (ADS)
Böhme, Martina; Hermanns, Reginald L.; Oppikofer, Thierry; Penna, Ivanna
2016-04-01
Unstable rock slopes that can cause large failures of the rock-avalanche type have been mapped in Norway for almost two decades. Four sites have earlier been characterized as high-risk objects based on expertise of few researchers. This resulted in installing continuous monitoring systems and set-up of an early-warning system for those four sites. Other unstable rock slopes have not been ranked related to their hazard or risk. There are ca. 300 other sites known of which 70 sites were installed for periodic deformation measurements using multiple techniques (Global Navigation Satellite Systems, extensometers, measurement bolts, and others). In 2012 a systematic hazard and risk classification system for unstable rock slopes was established in Norway and the mapping approach adapted to that in 2013. Now, the first 22 sites were classified for hazard, consequences and risk using this classification system. The selection of the first group of sites to be classified was based on an assumed high hazard or risk and importance given to the sites by Norwegian media and the public. Nine of the classified 22 unstable rock slopes are large sites that deform inhomogeneously or are strongly broken up in individual blocks. This suggests that different failure scenarios are possible that need to be analyzed individually. A total of 35 failure scenarios for those nine unstable rock slopes were considered. The hazard analyses were based on 9 geological parameters defined in the classification system. The classification system will be presented based on the Gamanjunni unstable rock slope. This slope has a well developed back scarp that exposes 150 m preceding displacement. The lateral limits of the unstable slope are clearly visible in the morphology and InSAR displacement data. There have been no single structures observed that allow sliding kinematically. The lower extend of the displacing rock mass is clearly defined in InSAR data and by a zone of higher rock fall activity. Yearly average displacement rates of up to 6 cm are measured with differential GNSS and InSAR. Cosmogenic nuclide dating suggests an acceleration of the present displacement compared to the average displacement since the initiation of the gravitational movement approximately 7000 years ago. Furthermore, there exists a pre-historic rock avalanche 3 km north along the same slope. These characteristics result in a very high hazard for the Gamanjunni unstable rock slope. The consequence analyses focus on the possibility of life loss only. For this the number of persons in the area that can be affected by either the rock slope failure itself and/or its secondary consequence of a displacement wave in case that a rock slope failure would hit a water body is estimated. For Gamanjunni the direct consequences are approximately 40 casualties, representing medium consequences. A total of 48 scenarios were finally analyzed for hazard, consequences and risk. The results are plotted in a risk matrix with 5 hazard and 5 consequence classes, leading to 4 risk classes. One unstable rock slope was classified as very high hazard, 9 scenarios as high hazard, 25 as medium hazard and 13 as low hazard, while none were classified as very low hazard. The consequence analyses for those scenarios resulted in 5 scenarios with very high consequences (>1000 potential casualties), 13 scenarios with high consequences (100-1000 casualties), 9 scenarios with medium consequences (10-100 casualties), 6 scenarios with low consequences (1-10 casualties) and 15 scenarios with very low consequences (0-1 casualties). This resulted in a high risk for 6 scenarios, medium to high risk for 16 scenarios, medium risk for 7 scenarios and low risk for 19 scenarios. These results allow determining which unstable rock slopes do not require further follow-up and on which further investigations and/or mitigation measures should be considered.
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2012 CFR
2012-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2013 CFR
2013-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2014 CFR
2014-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
14 CFR 417.409 - System hazard controls.
Code of Federal Regulations, 2011 CFR
2011-01-01
... hazard as identified by the ground safety analysis and satisfy the requirements of this section. A launch... electrical power and signal circuits that interface with hazardous subsystems. (e) Propulsion systems. A...
NASA Technical Reports Server (NTRS)
Downs, W. R.
1976-01-01
The potential flammability hazard when a water/glycol solution contacts defectively insulated silver-clad copper circuitry or electrical components carrying a direct current is described. The chemical reactions and means for detecting them are explained. Methods for detecting and cleaning contaminated areas and the use of inhibitors to arrest chemical reactivity are also explained. Preventive measures to minimize hazards are given. Photomicrographs of the chemical reactions occurring on silver clad wires are also included.
Magnetic storms and induction hazards
Love, Jeffrey J.; Rigler, E. Joshua; Pulkkinen, Antti; Balch, Christopher
2014-01-01
Magnetic storms are potentially hazardous to the activities and technological infrastructure of modern civilization. This reality was dramatically demonstrated during the great magnetic storm of March 1989, when surface geoelectric fields, produced by the interaction of the time-varying geomagnetic field with the Earth's electrically conducting interior, coupled onto the overlying Hydro-Québec electric power grid in Canada. Protective relays were tripped, the grid collapsed, and about 9 million people were temporarily left without electricity [Bolduc, 2002].
Everstine, Karen; Abt, Eileen; McColl, Diane; Popping, Bert; Morrison-Rowe, Sara; Lane, Richard W; Scimeca, Joseph; Winter, Carl; Ebert, Andrew; Moore, Jeffrey C; Chin, Henry B
2018-01-01
Food fraud, the intentional misrepresentation of the true identity of a food product or ingredient for economic gain, is a threat to consumer confidence and public health and has received increased attention from both regulators and the food industry. Following updates to food safety certification standards and publication of new U.S. regulatory requirements, we undertook a project to (i) develop a scheme to classify food fraud-related adulterants based on their potential health hazard and (ii) apply this scheme to the adulterants in a database of 2,970 food fraud records. The classification scheme was developed by a panel of experts in food safety and toxicology from the food industry, academia, and the U.S. Food and Drug Administration. Categories and subcategories were created through an iterative process of proposal, review, and validation using a subset of substances known to be associated with the fraudulent adulteration of foods. Once developed, the scheme was applied to the adulterants in the database. The resulting scheme included three broad categories: 1, potentially hazardous adulterants; 2, adulterants that are unlikely to be hazardous; and 3, unclassifiable adulterants. Categories 1 and 2 consisted of seven subcategories intended to further define the range of hazard potential for adulterants. Application of the scheme to the 1,294 adulterants in the database resulted in 45% of adulterants classified in category 1 (potentially hazardous). Twenty-seven percent of the 1,294 adulterants had a history of causing consumer illness or death, were associated with safety-related regulatory action, or were classified as allergens. These results reinforce the importance of including a consideration of food fraud-related adulterants in food safety systems. This classification scheme supports food fraud mitigation efforts and hazard identification as required in the U.S. Food Safety Modernization Act Preventive Controls Rules.
When air really matters: Flow depth relationships for stepped spillways
USDA-ARS?s Scientific Manuscript database
With changing demographics in the vicinity of aging embankment dams, hazard creep, a change in classification from low to significant or high, can become problematic and limit rehabilitation options. The most common deficiency for embankment dams due to hazard creep is inadequate spillway capacity....
Thermoacoustic energy effects in electrical arcs.
Capelli-Schellpfeffer, M; Miller, G H; Humilier, M
1999-10-30
Electrical arcs commonly occur in electrical injury incidents. Historically, safe work distances from an energized surface along with personal barrier protection have been employee safety strategies used to minimize electrical arc hazard exposures. Here, the two-dimensional computational simulation of an electrical arc explosion is reported using color graphics to depict the temperature and acoustic force propagation across the geometry of a hypothetical workroom during a time from 0 to 50 ms after the arc initiation. The theoretical results are compared to the experimental findings of staged tests involving a mannequin worker monitored for electrical current flow, temperature, and pressure, and reported data regarding neurologic injury thresholds. This report demonstrates a credible link between electrical explosions and the risk for pressure (acoustic) wave trauma. Our ultimate goal is to protect workers through the design and implementation of preventive strategies that properly account for all electrical arc-induced hazards, including electrical, thermal, and acoustic effects.
21 CFR 884.4120 - Gynecologic electrocautery and accessories.
Code of Federal Regulations, 2011 CFR
2011-04-01
... electrically heated probe. It is used to excise cervical lesions, perform biopsies, or treat chronic cervicitis... electrical generator, a probe, and electrical cables. (b) Classification. Class II (performance standards). ...
21 CFR 884.4120 - Gynecologic electrocautery and accessories.
Code of Federal Regulations, 2014 CFR
2014-04-01
... electrically heated probe. It is used to excise cervical lesions, perform biopsies, or treat chronic cervicitis... electrical generator, a probe, and electrical cables. (b) Classification. Class II (performance standards). ...
21 CFR 884.4120 - Gynecologic electrocautery and accessories.
Code of Federal Regulations, 2012 CFR
2012-04-01
... electrically heated probe. It is used to excise cervical lesions, perform biopsies, or treat chronic cervicitis... electrical generator, a probe, and electrical cables. (b) Classification. Class II (performance standards). ...
21 CFR 884.4120 - Gynecologic electrocautery and accessories.
Code of Federal Regulations, 2013 CFR
2013-04-01
... electrically heated probe. It is used to excise cervical lesions, perform biopsies, or treat chronic cervicitis... electrical generator, a probe, and electrical cables. (b) Classification. Class II (performance standards). ...
40 CFR 260.30 - Non-waste determinations and variances from classification as a solid waste.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 27 2012-07-01 2012-07-01 false Non-waste determinations and variances from classification as a solid waste. 260.30 Section 260.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking...
40 CFR 260.30 - Non-waste determinations and variances from classification as a solid waste.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 27 2013-07-01 2013-07-01 false Non-waste determinations and variances from classification as a solid waste. 260.30 Section 260.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking...
40 CFR 260.30 - Non-waste determinations and variances from classification as a solid waste.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 26 2014-07-01 2014-07-01 false Non-waste determinations and variances from classification as a solid waste. 260.30 Section 260.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking...
Hazardous Waste Cleanup: Amphenol Corporation-Benedix Connector Division in Sidney, New York
Amphenol Corporation is primarily a manufacturer of electrical components and connectors for the aircraft and aerospace industries. Hazardous wastes are generated through electroplating, vapor degreasing and parts-cleaning operations. Hazardous waste
Energy dissipation for flat-sloped stepped spillways using new inception point relationship
USDA-ARS?s Scientific Manuscript database
Transforming from a rural to an urban landscape has created a change in hazard classification for many earthen embankments. As a result, these facilities provide inadequate spillway capacity for the upgraded hazard rating. To bring these dams into compliance with state and federal dam safety regul...
16 CFR § 1500.85 - Exemptions from classification as banned hazardous substances.
Code of Federal Regulations, 2013 CFR
2013-01-01
... component has no hazards other than being in a self-pressurized container. (8) Model rocket propellant devices designed for use in light-weight, recoverable, and reflyable model rockets, provided such devices... recovery system activation devices intended for use with premanufactured model rocket engines wherein all...
16 CFR 1500.85 - Exemptions from classification as banned hazardous substances.
Code of Federal Regulations, 2014 CFR
2014-01-01
... component has no hazards other than being in a self-pressurized container. (8) Model rocket propellant devices designed for use in light-weight, recoverable, and reflyable model rockets, provided such devices... recovery system activation devices intended for use with premanufactured model rocket engines wherein all...
16 CFR 1500.85 - Exemptions from classification as banned hazardous substances.
Code of Federal Regulations, 2011 CFR
2011-01-01
... component has no hazards other than being in a self-pressurized container. (8) Model rocket propellant devices designed for use in light-weight, recoverable, and reflyable model rockets, provided such devices... recovery system activation devices intended for use with premanufactured model rocket engines wherein all...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
30 CFR 57.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Static electricity dissipation during loading... MINES Explosives Extraneous Electricity-Surface and Underground § 57.6602 Static electricity dissipation... generates a static electricity hazard— (a) An evaluation of the potential static electricity hazard shall be...
Electromagnetic Spectrum Test and Evaluation Process
2010-01-01
HERO , hazards of electromagnetic radiation to ordnance ; HERP, hazards of electromagnetic radiation to personnel; HERF, hazards of electromagnetic ... electromagnetic pulse (EMP); electronic protection; electrostatic dis- charge (ESD); hazards of electromagnetic radi- ation to personnel (HERP), ordnance ...including ordnance containing electrically initiated devices, to be mutually compatible in their intended
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 5 2010-10-01 2010-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 49 Transportation 5 2014-10-01 2014-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 49 Transportation 5 2011-10-01 2011-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 49 Transportation 5 2012-10-01 2012-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
49 CFR 393.19 - Hazard warning signals.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 49 Transportation 5 2013-10-01 2013-10-01 false Hazard warning signals. 393.19 Section 393.19... NECESSARY FOR SAFE OPERATION Lamps, Reflective Devices, and Electrical Wiring § 393.19 Hazard warning signals. The hazard warning signal operating unit on each commercial motor vehicle shall operate...
1986-03-01
Dietzmann L.R. Smith Engines, Emissions, and Vehicle Research Division Southwest Research Institute San Antonio, Texas Prepared for Belvoir Fuels and...replacing the currently used electric forklift with diesel engine-powered forklifts in handling hazardous materials. Electric -powered forklifts have no...diesel engines considered as potential candidates for forklift vehicles used to handle hazardous materials. The first program was conducted to
A hazard and risk classification system for catastrophic rock slope failures in Norway
NASA Astrophysics Data System (ADS)
Hermanns, R.; Oppikofer, T.; Anda, E.; Blikra, L. H.; Böhme, M.; Bunkholt, H.; Dahle, H.; Devoli, G.; Eikenæs, O.; Fischer, L.; Harbitz, C. B.; Jaboyedoff, M.; Loew, S.; Yugsi Molina, F. X.
2012-04-01
The Geological Survey of Norway carries out systematic geologic mapping of potentially unstable rock slopes in Norway that can cause a catastrophic failure. As catastrophic failure we describe failures that involve substantial fragmentation of the rock mass during run-out and that impact an area larger than that of a rock fall (shadow angle of ca. 28-32° for rock falls). This includes therefore rock slope failures that lead to secondary effects, such as a displacement wave when impacting a water body or damming of a narrow valley. Our systematic mapping revealed more than 280 rock slopes with significant postglacial deformation, which might represent localities of large future rock slope failures. This large number necessitates prioritization of follow-up activities, such as more detailed investigations, periodic monitoring and permanent monitoring and early-warning. In the past hazard and risk were assessed qualitatively for some sites, however, in order to compare sites so that political and financial decisions can be taken, it was necessary to develop a quantitative hazard and risk classification system. A preliminary classification system was presented and discussed with an expert group of Norwegian and international experts and afterwards adapted following their recommendations. This contribution presents the concept of this final hazard and risk classification that should be used in Norway in the upcoming years. Historical experience and possible future rockslide scenarios in Norway indicate that hazard assessment of large rock slope failures must be scenario-based, because intensity of deformation and present displacement rates, as well as the geological structures activated by the sliding rock mass can vary significantly on a given slope. In addition, for each scenario the run-out of the rock mass has to be evaluated. This includes the secondary effects such as generation of displacement waves or landslide damming of valleys with the potential of later outburst floods. It became obvious that large rock slope failures cannot be evaluated on a slope scale with frequency analyses of historical and prehistorical events only, as multiple rockslides have occurred within one century on a single slope that prior to the recent failures had been inactive for several thousand years. In addition, a systematic analysis on temporal distribution indicates that rockslide activity following deglaciation after the Last Glacial Maximum has been much higher than throughout the Holocene. Therefore the classification system has to be based primarily on the geological conditions on the deforming slope and on the deformation rates and only to a lesser weight on a frequency analyses. Our hazard classification therefore is primarily based on several criteria: 1) Development of the back-scarp, 2) development of the lateral release surfaces, 3) development of the potential basal sliding surface, 4) morphologic expression of the basal sliding surface, 5) kinematic feasibility tests for different displacement mechanisms, 6) landslide displacement rates, 7) change of displacement rates (acceleration), 8) increase of rockfall activity on the unstable rock slope, 9) Presence post-glacial events of similar size along the affected slope and its vicinity. For each of these criteria several conditions are possible to choose from (e.g. different velocity classes for the displacement rate criterion). A score is assigned to each condition and the sum of all scores gives the total susceptibility score. Since many of these observations are somewhat uncertain, the classification system is organized in a decision tree where probabilities can be assigned to each condition. All possibilities in the decision tree are computed and the individual probabilities giving the same total score are summed. Basic statistics show the minimum and maximum total scores of a scenario, as well as the mean and modal value. The final output is a cumulative frequency distribution of the susceptibility scores that can be divided into several classes, which are interpreted as susceptibility classes (very high, high, medium, low, and very low). Today the Norwegian Planning and Building Act uses hazard classes with annual probabilities of impact on buildings producing damages (<1/100, <1/1000, <1/5000 and zero for critical buildings). However, up to now there is not enough scientific knowledge to predict large rock slope failures in these strict classes. Therefore, the susceptibility classes will be matched with the hazard classes from the Norwegian Building Act (e.g. very high susceptibility represents the hazard class with annual probability >1/100). The risk analysis focuses on the potential fatalities of a worst case rock slide scenario and its secondary effects only and is done in consequence classes with a decimal logarithmic scale. However we recommend for all high risk objects that municipalities carry out detailed risk analyses. Finally, the hazard and risk classification system will give recommendations where surveillance in form of continuous 24/7 monitoring systems coupled with early-warning systems (high risk class) or periodic monitoring (medium risk class) should be carried out. These measures are understood as to reduce the risk of life loss due to a rock slope failure close to 0 as population can be evacuated on time if a change of stability situation occurs. The final hazard and risk classification for all potentially unstable rock slopes in Norway, including all data used for its classification will be published within the national landslide database (available on www.skrednett.no).
NASA Astrophysics Data System (ADS)
Sliney, David H.
1990-07-01
Historically many different agencies and standards organizations have proposed laser occupational exposure limits (EL1s) or maximum permissible exposure (MPE) levels. Although some safety standards have been limited in scope to manufacturer system safety performance standards or to codes of practice most have included occupational EL''s. Initially in the 1960''s attention was drawn to setting EL''s however as greater experience accumulated in the use of lasers and some accident experience had been gained safety procedures were developed. It became clear by 1971 after the first decade of laser use that detailed hazard evaluation of each laser environment was too complex for most users and a scheme of hazard classification evolved. Today most countries follow a scheme of four major hazard classifications as defined in Document WS 825 of the International Electrotechnical Commission (IEC). The classifications and the associated accessible emission limits (AEL''s) were based upon the EL''s. The EL and AEL values today are in surprisingly good agreement worldwide. There exists a greater range of safety requirements for the user for each class of laser. The current MPE''s (i. e. EL''s) and their basis are highlighted in this presentation. 2. 0
Ta, Goh Choo; Mokhtar, Mazlin Bin; Mohd Mokhtar, Hj Anuar Bin; Ismail, Azmir Bin; Abu Yazid, Mohd Fadhil Bin Hj
2010-01-01
Chemical classification and labelling systems may be roughly similar from one country to another but there are significant differences too. In order to harmonize various chemical classification systems and ultimately provide consistent chemical hazard communication tools worldwide, the Globally Harmonized System of Classification and Labelling of Chemicals (GHS) was endorsed by the United Nations Economic and Social Council (ECOSOC). Several countries, including Japan, Taiwan, Korea and Malaysia, are now in the process of implementing GHS. It is essential to ascertain the comprehensibility of chemical hazard communication tools that are described in the GHS documents, namely the chemical labels and Safety Data Sheets (SDS). Comprehensibility Testing (CT) was carried out with a mixed group of industrial workers in Malaysia (n=150) and factors that influence the comprehensibility were analysed using one-way ANOVA. The ability of the respondents to retrieve information from the SDS was also tested in this study. The findings show that almost all the GHS pictograms meet the ISO comprehension criteria and it is concluded that the underlying core elements that enhance comprehension of GHS pictograms and which are also essential in developing competent persons in the use of SDS are training and education.
Sparse kernel methods for high-dimensional survival data.
Evers, Ludger; Messow, Claudia-Martina
2008-07-15
Sparse kernel methods like support vector machines (SVM) have been applied with great success to classification and (standard) regression settings. Existing support vector classification and regression techniques however are not suitable for partly censored survival data, which are typically analysed using Cox's proportional hazards model. As the partial likelihood of the proportional hazards model only depends on the covariates through inner products, it can be 'kernelized'. The kernelized proportional hazards model however yields a solution that is dense, i.e. the solution depends on all observations. One of the key features of an SVM is that it yields a sparse solution, depending only on a small fraction of the training data. We propose two methods. One is based on a geometric idea, where-akin to support vector classification-the margin between the failed observation and the observations currently at risk is maximised. The other approach is based on obtaining a sparse model by adding observations one after another akin to the Import Vector Machine (IVM). Data examples studied suggest that both methods can outperform competing approaches. Software is available under the GNU Public License as an R package and can be obtained from the first author's website http://www.maths.bris.ac.uk/~maxle/software.html.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-08-02
... Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility...-fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired...
Standoff detection: distinction of bacteria by hyperspectral laser induced fluorescence
NASA Astrophysics Data System (ADS)
Walter, Arne; Duschek, Frank; Fellner, Lea; Grünewald, Karin M.; Hausmann, Anita; Julich, Sandra; Pargmann, Carsten; Tomaso, Herbert; Handke, Jürgen
2016-05-01
Sensitive detection and rapid identification of hazardous bioorganic material with high sensitivity and specificity are essential topics for defense and security. A single method can hardly cover these requirements. While point sensors allow a highly specific identification, they only provide localized information and are comparatively slow. Laser based standoff systems allow almost real-time detection and classification of potentially hazardous material in a wide area and can provide information on how the aerosol may spread. The coupling of both methods may be a promising solution to optimize the acquisition and identification of hazardous substances. The capability of the outdoor LIF system at DLR Lampoldshausen test facility as an online classification tool has already been demonstrated. Here, we present promising data for further differentiation among bacteria. Bacteria species can express unique fluorescence spectra after excitation at 280 nm and 355 nm. Upon deactivation, the spectral features change depending on the deactivation method.
Fuel Characteristic Classification System version 3.0: technical documentation
Susan J. Prichard; David V. Sandberg; Roger D. Ottmar; Ellen Eberhardt; Anne Andreu; Paige Eagle; Kjell Swedin
2013-01-01
The Fuel Characteristic Classification System (FCCS) is a software module that records wildland fuel characteristics and calculates potential fire behavior and hazard potentials based on input environmental variables. The FCCS 3.0 is housed within the Integrated Fuels Treatment Decision Support System (Joint Fire Science Program 2012). It can also be run from command...
Architecting the Safety Assessment of Large-scale Systems Integration
2009-12-01
Electromagnetic Radiation to Ordnance ( HERO ) Hazards of Electromagnetic Radiation to Fuel (HERF) The main reason that this particular safety study... radiation , high voltage electric shocks and explosives safety. 1. Radiation Hazards (RADHAZ) RADHAZ describes the hazards of electromagnetic radiation ...OP3565/NAVAIR 16-1-529 [19 and 20], these hazards are segregated as follows: Hazards of Electromagnetic
ERIC Educational Resources Information Center
Ohio State Dept. of Education, Columbus. Div. of Vocational Education.
This training manual for emergency medical technicians, one of 14 modules that comprise the Emergency Victim Care textbook, covers water accidents, electrical emergencies, and hazardous materials and radiation accidents. Objectives stated for the three chapters are for the students to be able to describe: emergency care for specified water…
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
30 CFR 56.6602 - Static electricity dissipation during loading.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Static electricity dissipation during loading... Explosives Extraneous Electricity § 56.6602 Static electricity dissipation during loading. When explosive material is loaded pneumatically into a blasthole in a manner that generates a static electricity hazard...
46 CFR 111.106-17 - Piping: electrical bonding.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Piping: electrical bonding. 111.106-17 Section 111.106-17 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations on OSVs § 111.106-17 Piping: electrical bonding. (a...
Atmospheric Electrical Modeling in Support of the NASA F-106 Storm Hazards Project
NASA Technical Reports Server (NTRS)
Helsdon, John H., Jr.
1988-01-01
A recently developed storm electrification model (SEM) is used to investigate the operating environment of the F-106 airplane during the NASA Storm Hazards Project. The model is 2-D, time dependent and uses a bulkwater microphysical parameterization scheme. Electric charges and fields are included, and the model is fully coupled dynamically, microphysically and electrically. One flight showed that a high electric field was developed at the aircraft's operating altitude (28 kft) and that a strong electric field would also be found below 20 kft; however, this low-altitude, high-field region was associated with the presence of small hail, posing a hazard to the aircraft. An operational procedure to increase the frequency of low-altitude lightning strikes was suggested. To further the understanding of lightning within the cloud environment, a parameterization of the lightning process was included in the SEM. It accounted for the initiation, propagation, termination, and charge redistribution associated with an intracloud discharge. Finally, a randomized lightning propagation scheme was developed, and the effects of cloud particles on the initiation of lightning investigated.
NASA Astrophysics Data System (ADS)
Iribarren Anacona, P.; Norton, K. P.; Mackintosh, A.
2014-07-01
Glacier retreat since the Little Ice Age has resulted in the development or expansion of hundreds of glacial lakes in Patagonia. Some of these lakes have produced large (≥106 m3) Glacial Lake Outburst Floods (GLOFs) damaging inhabited areas. GLOF hazard studies in Patagonia have been mainly based on the analysis of short-term series (≤50 years) of flood data and until now no attempt has been made to identify the relative susceptibility of lakes to failure. Power schemes and associated infrastructure are planned for Patagonian basins that have historically been affected by GLOFs, and we now require a thorough understanding of the characteristics of dangerous lakes in order to assist with hazard assessment and planning. In this paper, the conditioning factors of 16 outbursts from moraine dammed lakes in Patagonia were analysed. These data were used to develop a classification scheme designed to assess outburst susceptibility, based on image classification techniques, flow routine algorithms and the Analytical Hierarchy Process. This scheme was applied to the Baker Basin, Chile, where at least 7 moraine-dammed lakes have failed in historic time. We identified 386 moraine-dammed lakes in the Baker Basin of which 28 were classified with high or very high outburst susceptibility. Commonly, lakes with high outburst susceptibility are in contact with glaciers and have moderate (>8°) to steep (>15°) dam outlet slopes, akin to failed lakes in Patagonia. The proposed classification scheme is suitable for first-order GLOF hazard assessments in this region. However, rapidly changing glaciers in Patagonia make detailed analysis and monitoring of hazardous lakes and glaciated areas upstream from inhabited areas or critical infrastructure necessary, in order to better prepare for hazards emerging from an evolving cryosphere.
NASA Astrophysics Data System (ADS)
Iribarren Anacona, P.; Norton, K. P.; Mackintosh, A.
2014-12-01
Glacier retreat since the Little Ice Age has resulted in the development or expansion of hundreds of glacial lakes in Patagonia. Some of these lakes have produced large (≥ 106 m3) Glacial Lake Outburst Floods (GLOFs) damaging inhabited areas. GLOF hazard studies in Patagonia have been mainly based on the analysis of short-term series (≤ 50 years) of flood data and until now no attempt has been made to identify the relative susceptibility of lakes to failure. Power schemes and associated infrastructure are planned for Patagonian basins that have historically been affected by GLOFs, and we now require a thorough understanding of the characteristics of dangerous lakes in order to assist with hazard assessment and planning. In this paper, the conditioning factors of 16 outbursts from moraine-dammed lakes in Patagonia were analysed. These data were used to develop a classification scheme designed to assess outburst susceptibility, based on image classification techniques, flow routine algorithms and the Analytical Hierarchy Process. This scheme was applied to the Baker Basin, Chile, where at least seven moraine-dammed lakes have failed in historic time. We identified 386 moraine-dammed lakes in the Baker Basin of which 28 were classified with high or very high outburst susceptibility. Commonly, lakes with high outburst susceptibility are in contact with glaciers and have moderate (> 8°) to steep (> 15°) dam outlet slopes, akin to failed lakes in Patagonia. The proposed classification scheme is suitable for first-order GLOF hazard assessments in this region. However, rapidly changing glaciers in Patagonia make detailed analysis and monitoring of hazardous lakes and glaciated areas upstream from inhabited areas or critical infrastructure necessary, in order to better prepare for hazards emerging from an evolving cryosphere.
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-1 General. (a) Electric installations on vessels must ensure: (1) Maintenance of services... persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-1 General. (a) Electric installations on vessels must ensure: (1) Maintenance of services... persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS General § 111.01-1 General. (a) Electric installations on vessels must ensure: (1) Maintenance of services... persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-16
... Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility... Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial... electric utility steam generating units (EGUs) and standards of performance for fossil-fuel-fired electric...
Dental Laboratory Respiratory Hazards and Vacuum Performance Parameters.
1986-11-01
DENTAL LABORATORY RESPIRATORY HZRS AND VACUUMPERFORMANCE PRANETERS(U) SCHOOL OF AEROSPACE MEDICINE BROOKS AFB TX K D SATRON ET AL. NOV 86...34 " " " "" .. . . . . .," ." - " -’ " "’,".", "- " ".". ’-"’’. ,.’- " = ". - ’ . .- ., USAFSAM-TR-86-25 DENTAL LABORATORY RESPIRATORY HAZARDS AND VACUUM PERFORMANCE c...Security Classification) Dental Laboratory Respiratory Hazards and Vacuum Performance Parameters 12. PERSONAL AUTHOR(S) Satrom, Kirk D.; Callison,
Recovering and recycling Hg from chlor-alkali plant wastewater sludge
NASA Astrophysics Data System (ADS)
Twidwell, L. G.; Thompson, R. J.
2001-01-01
Montana Tech of the University of Montana and Universal Dynamics of British Columbia have developed a hydrometallurgical process for recovering and recycling mercury from chlorine plant wastewater sludge materials (U.S. Environmental Protection Agency [EPA]hazardous-waste classification K106). The hydrometallurgical process is also applicable for the treatment of mercury-contaminated soils (EPA hazardous waste classification D009) and other mercury-bearing waste materials. The process, which is capable of lowering the mercury content in the K106 solids from 10% to <50 mg/kg Hg, has been commercialized and utilized at three U.S. plants. This paper describes the fundamental chemistry of the process, the flowsheet being used, and operating plant case histories.
Safety Assessment of Multi Purpose Small Payload Rack(MSPR)
NASA Astrophysics Data System (ADS)
Mizutani, Yoshinobu; Takada, Satomi; Murata, Kosei; Ozawa, Daisaku; Kobayashi, Ryoji; Nakamura, Yasuhiro
2010-09-01
We are reporting summary of preliminary safety assessment for Multi Purpose Small Payload Rack(MSPR), which is one of the micro gravity experiment facilities that are being developed for the 2nd phase JEM utilization(JEM: Japanese Experiment Module) that will be launched on H-II Transfer Vehicle(HTV) 2nd flight in 2011. MSPR is used for multi-purpose micro-g experiment providing experimental spaces and work stations. MSPR has three experimental spaces; first, there is a space called Work Volume(WV) with capacity volume of approximately 350 litters, in which multiple resources including electricity, communication, and moving image functions can be used. Within this space, installation of devices can be done by simple, prompt attachment by Velcro and pins with high degree of flexibility. Second, there is Small Experiment Area(SEA), with capacity volume of approximately 70 litters, in which electricity, communication, and moving image functions can also be used in the same way as WV. These spaces protect experiment devices and specimens from contingent loads by the crewmembers. Third, there is Work Bench with area of 0.5 square meters, on which can be used for maintenance, inspection and data operations of installed devices, etc. This bench can be stored in the rack during contingency. Chamber for Combustion Experiment(CCE) that is planned to be installed in WV is a pressure-resistant experimental container that can be used to seal hazardous materials from combustion experiments. This CCE has double sealing design in chamber itself, which resist gas leakage under normal the temperature and pressure. Electricity, communication, moving image function can be used in the same way as WV. JAXA Phase 2 Safety Review Panel(SRP) has been held in April, 2010. For safety analysis of MSPR, hazards were identified based on Fault Tree Analysis methodology and then these hazards were classified into either eight ISS standard-type hazards or eight unique-type hazards that requires special controls based on ISS common safety assessment methodology. Safety evaluation results are reported in the Safety Assessment Report(SAR) 1). Regarding structural failure, unique hazards are especially evaluated considering not only the tolerance for launch load but also load by crewmembers or orbital loads. Regarding electrical shock, electricity design up to secondary power is evaluated in unique hazard from a view point of Electrical design suitable for high voltage(32VDC or more) circuit. Regarding rupture/leakage of pressure system, hazards of fuel supply line, waste line for combustion gas, and pressure system including CCE are evaluated. Also evaluation for contamination due to hazardous gas leakage from CCE is conducted. External propagation of fire from CCE is also evaluated. In this report, we will show the overview of the result of safety assessment and future plan toward critical design phase activity.
Code of Federal Regulations, 2013 CFR
2013-07-01
... classification as a solid waste, for variances to be classified as a boiler, or for non-waste determinations. 260.33 Section 260.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking Petitions § 260.33 Procedures for variances...
Code of Federal Regulations, 2014 CFR
2014-07-01
... classification as a solid waste, for variances to be classified as a boiler, or for non-waste determinations. 260.33 Section 260.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking Petitions § 260.33 Procedures for variances...
Code of Federal Regulations, 2012 CFR
2012-07-01
... classification as a solid waste, for variances to be classified as a boiler, or for non-waste determinations. 260.33 Section 260.33 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES (CONTINUED) HAZARDOUS WASTE MANAGEMENT SYSTEM: GENERAL Rulemaking Petitions § 260.33 Procedures for variances...
Regional United States electric field and GIC hazard impacts (Invited)
NASA Astrophysics Data System (ADS)
Gannon, J. L.; Balch, C. C.; Trichtchenko, L.
2013-12-01
Geomagnetically Induced Currents (GICs) are primarily driven by impulsive geomagnetic disturbances created by the interaction between the Earth's magnetosphere and sharp velocity, density, and magnetic field enhancements in the solar wind. However, the magnitude of the induced electric field response at the ground level, and therefore the resulting hazard to the bulk power system, is determined not only by magnetic drivers, but also by the underlying geology. Convolution techniques are used to calculate surface electric fields beginning from the spectral characteristics of magnetic field drivers and the frequency response of the local geology. Using these techniques, we describe historical scenarios for regions across the United States, and the potential impact of large events on electric power infrastructure.
46 CFR 108.187 - Ventilation for brush type electric motors in classified spaces.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Ventilation for brush type electric motors in classified... Ventilation for brush type electric motors in classified spaces. Ventilation for brush type electric motors in... Electrical Equipment in Hazardous Locations”, except audible and visual alarms may be used if shutting down...
Preliminary Considerations for Classifying Hazards of Unmanned Aircraft Systems
NASA Technical Reports Server (NTRS)
Hayhurst, Kelly J.; Maddalon, Jeffrey M.; Miner, Paul S.; Szatkowski, George N.; Ulrey, Michael L.; DeWalt, Michael P.; Spitzer, Cary R.
2007-01-01
The use of unmanned aircraft in national airspace has been characterized as the next great step forward in the evolution of civil aviation. To make routine and safe operation of these aircraft a reality, a number of technological and regulatory challenges must be overcome. This report discusses some of the regulatory challenges with respect to deriving safety and reliability requirements for unmanned aircraft. In particular, definitions of hazards and their classification are discussed and applied to a preliminary functional hazard assessment of a generic unmanned system.
Hazard detection and avoidance sensor for NASA's planetary landers
NASA Technical Reports Server (NTRS)
Lau, Brian; Chao, Tien-Hsin
1992-01-01
An optical terrain analysis based sensor system specifically designed for landing hazard detection as required for NASA's autonomous planetary landers is introduced. This optical hazard detection and avoidance (HDA) sensor utilizes an optoelectronic wedge-and-ting (WRD) filter for Fourier transformed feature extraction and an electronic neural network processor for pattern classification. A fully implemented optical HDA sensor would assure safe landing of the planetary landers. Computer simulation results of a successful feasibility study is reported. Future research for hardware system implementation is also provided.
NASA Astrophysics Data System (ADS)
Kang, S.; Kim, K.
2013-12-01
Regionally varying seismic hazards can be estimated using an earthquake loss estimation system (e.g. HAZUS-MH). The estimations for actual earthquakes help federal and local authorities develop rapid, effective recovery measures. Estimates for scenario earthquakes help in designing a comprehensive earthquake hazard mitigation plan. Local site characteristics influence the ground motion. Although direct measurements are desirable to construct a site-amplification map, such data are expensive and time consuming to collect. Thus we derived a site classification map of the southern Korean Peninsula using geologic and geomorphologic data, which are readily available for the entire southern Korean Peninsula. Class B sites (mainly rock) are predominant in the area, although localized areas of softer soils are found along major rivers and seashores. The site classification map is compared with independent site classification studies to confirm our site classification map effectively represents the local behavior of site amplification during an earthquake. We then estimated the losses due to a magnitude 6.7 scenario earthquake in Gyeongju, southeastern Korea, with and without the site classification map. Significant differences in loss estimates were observed. The loss without the site classification map decreased without variation with increasing epicentral distance, while the loss with the site classification map varied from region to region, due to both the epicentral distance and local site effects. The major cause of the large loss expected in Gyeongju is the short epicentral distance. Pohang Nam-Gu is located farther from the earthquake source region. Nonetheless, the loss estimates in the remote city are as large as those in Gyeongju and are attributed to the site effect of soft soil found widely in the area.
NASA Technical Reports Server (NTRS)
Kerslake, Thomas W.; Scheiman, David A.
2005-01-01
This paper documents testing and analyses to quantify International Space Station (ISS) Solar Array Wing (SAW) string electrical performance under highly off-nominal, low-temperature-low-intensity (LILT) operating conditions with nonsolar light sources. This work is relevant for assessing feasibility and risks associated with a Sequential Shunt Unit (SSU) remove and replace (R&R) Extravehicular Activity (EVA). During eclipse, SAW strings can be energized by moonlight, EVA suit helmet lights or video camera lights. To quantify SAW performance under these off-nominal conditions, solar cell performance testing was performed using full moon, solar simulator and Video Camera Luminaire (VCL) light sources. Test conditions included 25 to 110 C temperatures and 1- to 0.0001-Sun illumination intensities. Electrical performance data and calculated eclipse lighting intensities were combined to predict SAW current-voltage output for comparison with electrical hazard thresholds. Worst case predictions show there is no connector pin molten metal hazard but crew shock hazard limits are exceeded due to VCL illumination. Assessment uncertainties and limitations are discussed along with operational solutions to mitigate SAW electrical hazards from VCL illumination. Results from a preliminary assessment of SAW arcing are also discussed. The authors recommend further analyses once SSU, R&R, and EVA procedures are better defined.
Protect Yourself and Others from Electrical Hazards after a Disaster
... emergency medical help . Turn off the source of electricity if possible. If not, move the source away ... the person is free of the source of electricity, check the person’s breathing and pulse. If either ...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 2 2013-07-01 2013-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 2 2010-07-01 2010-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 2 2012-07-01 2012-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 2 2011-07-01 2011-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
33 CFR 127.1107 - Electrical systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 2 2014-07-01 2014-07-01 false Electrical systems. 127.1107... Waterfront Facilities Handling Liquefied Hazardous Gas Design and Construction § 127.1107 Electrical systems. Electrical equipment and wiring must be of the kind specified by, and must be installed in accordance with...
30 CFR 250.114 - How must I install and operate electrical equipment?
Code of Federal Regulations, 2012 CFR
2012-07-01
... their facilities. (a) You must classify all areas according to API RP 500, Recommended Practice for... 1 and Division 2, or API RP 505, Recommended Practice for Classification of Locations for Electrical... electrical systems according to API RP 14F, Recommended Practice for Design and Installation of Electrical...
30 CFR 250.114 - How must I install and operate electrical equipment?
Code of Federal Regulations, 2014 CFR
2014-07-01
... their facilities. (a) You must classify all areas according to API RP 500, Recommended Practice for... 1 and Division 2, or API RP 505, Recommended Practice for Classification of Locations for Electrical... electrical systems according to API RP 14F, Recommended Practice for Design and Installation of Electrical...
30 CFR 250.114 - How must I install and operate electrical equipment?
Code of Federal Regulations, 2013 CFR
2013-07-01
... their facilities. (a) You must classify all areas according to API RP 500, Recommended Practice for... 1 and Division 2, or API RP 505, Recommended Practice for Classification of Locations for Electrical... electrical systems according to API RP 14F, Recommended Practice for Design and Installation of Electrical...
An ecotoxicological approach for hazard identification of energy ash.
Stiernström, S; Hemström, K; Wik, O; Carlsson, G; Bengtsson, B-E; Breitholtz, M
2011-02-01
Within the EU, ash should be classified by its inherent hazardous effects under criterion H-14 (ecotoxic) in the Directive on waste (2008/98/EC). Today, however, there are no harmonized quantitative criterions for such a classification, but it is stated that biological test systems can be used. In this study seven ash materials were leached and characterized, both biologically and chemically. The objectives were to evaluate if (a) clear concentration-response relationships could be achieved for the selected toxicity tests (bacteria, algae, crustacean and fish), (b) some test(s) are generally more sensitive and (c) the toxic responses were consistent with the chemical analyzes. Interestingly, our results indicate that high concentrations of non-hazardous components (Ca, K) influenced the toxicity of almost all ash eluates, whereas hazardous components (e.g. Zn, Pb) only influenced the toxicity of the eluates ranked as most hazardous. If considering both hazardous and non-hazardous substances, the observed toxic responses were relatively consistent with the chemical analyzes. Our results further showed that the (sub)chronic tests were much more sensitive than the acute tests. However, the use of extrapolation factors to compensate for using the less sensitive acute tests will likely lead to either over- or underestimations of toxicity. Our recommendation is therefore that classification of waste according to H-14 should be based on (sub)chronic test data. Finally, given that treatment of the eluates prior to toxicity testing has a major significance on the concentration and speciation of released substances, further studies are needed in order to propose a relevant testing scheme. Copyright © 2010 Elsevier Ltd. All rights reserved.
Electrical Safety: Safety and Health for Electrical Trades. Student Manual.
ERIC Educational Resources Information Center
Fowler, Thaddeus W.; Miles, Karen K.
This document is designed to teach learners in secondary and postsecondary electrical trades courses to recognize, evaluate, and control hazards associated with electrical work, The manual's eight sections each include some or all of the following components: instructional text; definitions; case studies illustrating key safety considerations;…
Man-rating of a launch vehicle
NASA Astrophysics Data System (ADS)
Soeffker, D.
Analysis techniques for hazard identification, classification, and control, developed for Spacelab, are presented. Hazards were classified as catastrophic (leading to crew or vehicle loss) critical (could lead to serious injury or damage) and controlled (counteracted by design). All nonmetallic materials were rated for flammability in oxygen enriched atmospheres, toxic offgassing, and odor. Any element with less than 200 mission capability was rated life limited.
NASA Astrophysics Data System (ADS)
Thompson, M. A.; Lindsay, J. M.; Gaillard, J.
2015-12-01
Globally, geological hazards are communicated using maps. In traditional hazard mapping practice, scientists analyse data about a hazard, and then display the results on a map for stakeholder and public use. However, this one-way, top-down approach to hazard communication is not necessarily effective or reliable. The messages which people take away will be dependent on the way in which they read, interpret, and understand the map, a facet of hazard communication which has been relatively unexplored. Decades of cartographic studies suggest that variables in the visual representation of data on maps, such as colour and symbology, can have a powerful effect on how people understand map content. In practice, however, there is little guidance or consistency in how hazard information is expressed and represented on maps. Accordingly, decisions are often made based on subjective preference, rather than research-backed principles. Here we present the results of a study in which we explore how hazard map design features can influence hazard map interpretation, and we propose a number of considerations for hazard map design. A series of hazard maps were generated, with each one showing the same probabilistic volcanic ashfall dataset, but using different verbal and visual variables (e.g., different colour schemes, data classifications, probabilistic formats). Following a short pilot study, these maps were used in an online survey of 110 stakeholders and scientists in New Zealand. Participants answered 30 open-ended and multiple choice questions about ashfall hazard based on the different maps. Results suggest that hazard map design can have a significant influence on the messages readers take away. For example, diverging colour schemes were associated with concepts of "risk" and decision-making more than sequential schemes, and participants made more precise estimates of hazard with isarithmic data classifications compared to binned or gradational shading. Based on such findings, we make a number of suggestions for communicating hazard using maps. Most importantly, we emphasise that multiple meanings may be taken away from a map, and this may have important implications in a crisis. We propose that engaging with map audiences in a two-way dialogue in times of peace may help prevent miscommunications in the event of a crisis.
30 CFR 46.5 - New miner training.
Code of Federal Regulations, 2010 CFR
2010-07-01
... the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and loose or... aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition training specific...
30 CFR 46.5 - New miner training.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and loose or... aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition training specific...
30 CFR 19.8 - Protection against bodily hazard.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Protection against bodily hazard. 19.8 Section 19.8 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR TESTING, EVALUATION, AND APPROVAL OF MINING PRODUCTS ELECTRIC CAP LAMPS § 19.8 Protection against bodily hazard. This...
49 CFR 1245.6 - Cross reference to standard occupational classification manual.
Code of Federal Regulations, 2013 CFR
2013-10-01
...: Electrical Worker (lineman) 6433. Electrical Worker (groundsman) 6432. Communications Maintainer 6151... Maintainer Helper 8635. 320Camp Car Cooks: Camp Car Cook 5214. Camp Car Helper 5219. 400Maintenance of... Reclamations Plant 6318. Assist. General Foreman 6318. 403Equipment, Shop, Electrical Inspectors: Chief...
49 CFR 1245.6 - Cross reference to standard occupational classification manual.
Code of Federal Regulations, 2012 CFR
2012-10-01
...: Electrical Worker (lineman) 6433. Electrical Worker (groundsman) 6432. Communications Maintainer 6151... Maintainer Helper 8635. 320Camp Car Cooks: Camp Car Cook 5214. Camp Car Helper 5219. 400Maintenance of... Reclamations Plant 6318. Assist. General Foreman 6318. 403Equipment, Shop, Electrical Inspectors: Chief...
49 CFR 1245.6 - Cross reference to standard occupational classification manual.
Code of Federal Regulations, 2014 CFR
2014-10-01
...: Electrical Worker (lineman) 6433. Electrical Worker (groundsman) 6432. Communications Maintainer 6151... Maintainer Helper 8635. 320Camp Car Cooks: Camp Car Cook 5214. Camp Car Helper 5219. 400Maintenance of... Reclamations Plant 6318. Assist. General Foreman 6318. 403Equipment, Shop, Electrical Inspectors: Chief...
30 CFR 250.1628 - Design, installation, and operation of production systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... mechanical and electrical systems to be installed was approved by registered professional engineers. After... Installation of Offshore Production Platform Piping Systems; (3) Electrical system information including a plan... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as...
Lithner, Delilah; Larsson, Ake; Dave, Göran
2011-08-15
Plastics constitute a large material group with a global annual production that has doubled in 15 years (245 million tonnes in 2008). Plastics are present everywhere in society and the environment, especially the marine environment, where large amounts of plastic waste accumulate. The knowledge of human and environmental hazards and risks from chemicals associated with the diversity of plastic products is very limited. Most chemicals used for producing plastic polymers are derived from non-renewable crude oil, and several are hazardous. These may be released during the production, use and disposal of the plastic product. In this study the environmental and health hazards of chemicals used in 55 thermoplastic and thermosetting polymers were identified and compiled. A hazard ranking model was developed for the hazard classes and categories in the EU classification and labelling (CLP) regulation which is based on the UN Globally Harmonized System. The polymers were ranked based on monomer hazard classifications, and initial assessments were made. The polymers that ranked as most hazardous are made of monomers classified as mutagenic and/or carcinogenic (category 1A or 1B). These belong to the polymer families of polyurethanes, polyacrylonitriles, polyvinyl chloride, epoxy resins, and styrenic copolymers. All have a large global annual production (1-37 million tonnes). A considerable number of polymers (31 out of 55) are made of monomers that belong to the two worst of the ranking model's five hazard levels, i.e. levels IV-V. The polymers that are made of level IV monomers and have a large global annual production (1-5 million tonnes) are phenol formaldehyde resins, unsaturated polyesters, polycarbonate, polymethyl methacrylate, and urea-formaldehyde resins. This study has identified hazardous substances used in polymer production for which the risks should be evaluated for decisions on the need for risk reduction measures, substitution, or even phase out. Copyright © 2011 Elsevier B.V. All rights reserved.
A Study of Aircraft Fire Hazards Related to Natural Electrical Phenomena
NASA Technical Reports Server (NTRS)
Kester, Frank L.; Gerstein, Melvin; Plumer, J. A.
1960-01-01
The problems of natural electrical phenomena as a fire hazard to aircraft are evaluated. Assessment of the hazard is made over the range of low level electrical discharges, such as static sparks, to high level discharges, such as lightning strikes to aircraft. In addition, some fundamental work is presented on the problem of flame propagation in aircraft fuel vent systems. This study consists of a laboratory investigation in five parts: (1) a study of the ignition energies and flame propagation rates of kerosene-air and JP-6-air foams, (2) a study of the rate of flame propagation of n-heptane, n-octane, n-nonane, and n-decane in aircraft vent ducts, (3) a study of the damage to aluminum, titanium, and stainless steel aircraft skin materials by lightning strikes, (4) a study of fuel ignition by lightning strikes to aircraft skins, and (5) a study of lightning induced flame propagation in an aircraft vent system.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-23
... Mitigation measures Excessive laser power Electrical safety and electromagnetic compatibility (EMC... should validate electromagnetic compatibility (EMC), electrical safety, and battery characteristics; (4...
Toward a Reasoned Classification of Diseases Using Physico-Chemical Based Phenotypes
Schwartz, Laurent; Lafitte, Olivier; da Veiga Moreira, Jorgelindo
2018-01-01
Background: Diseases and health conditions have been classified according to anatomical site, etiological, and clinical criteria. Physico-chemical mechanisms underlying the biology of diseases, such as the flow of energy through cells and tissues, have been often overlooked in classification systems. Objective: We propose a conceptual framework toward the development of an energy-oriented classification of diseases, based on the principles of physical chemistry. Methods: A review of literature on the physical chemistry of biological interactions in a number of diseases is traced from the point of view of the fluid and solid mechanics, electricity, and chemistry. Results: We found consistent evidence in literature of decreased and/or increased physical and chemical forces intertwined with biological processes of numerous diseases, which allowed the identification of mechanical, electric and chemical phenotypes of diseases. Discussion: Biological mechanisms of diseases need to be evaluated and integrated into more comprehensive theories that should account with principles of physics and chemistry. A hypothetical model is proposed relating the natural history of diseases to mechanical stress, electric field, and chemical equilibria (ATP) changes. The present perspective toward an innovative disease classification may improve drug-repurposing strategies in the future. PMID:29541031
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1989-01-01
This book includes specifications and classifications from ASTM committees on paint and related coatings and materials; road and paving materials; wood; roofing, waterproofing and bituminous materials; rubber; soaps and other detergents; aromatic hydrocarbons and related chemicals; and electrical insulating liquids and gases. Also included are several related, important specifications and classifications from other organizations.
Influence of leaching conditions for ecotoxicological classification of ash.
Stiernström, S; Enell, A; Wik, O; Hemström, K; Breitholtz, M
2014-02-01
The Waste Framework Directive (WFD; 2008/98/EC) states that classification of hazardous ecotoxicological properties of wastes (i.e. criteria H-14), should be based on the Community legislation on chemicals (i.e. CLP Regulation 1272/2008). However, harmonizing the waste and chemical classification may involve drastic changes related to choice of leaching tests as compared to e.g. the current European standard for ecotoxic characterization of waste (CEN 14735). The primary aim of the present study was therefore to evaluate the influence of leaching conditions, i.e. pH (inherent pH (∼10), and 7), liquid to solid (L/S) ratio (10 and 1000 L/kg) and particle size (<4 mm, <1 mm, and <0.125 mm), for subsequent chemical analysis and ecotoxicity testing in relation to classification of municipal waste incineration bottom ash. The hazard potential, based on either comparisons between element levels in leachate and literature toxicity data or ecotoxicity testing of the leachates, was overall significantly higher at low particle size (<0.125 mm) as compared to particle fractions <1mm and <4mm, at pH 10 as compared to pH 7, and at L/S 10 as compared to L/S 1000. These results show that the choice of leaching conditions is crucial for H-14 classification of ash and must be carefully considered in deciding on future guidance procedures in Europe. Copyright © 2013 Elsevier Ltd. All rights reserved.
1979-03-01
showed the dam to be in good c~rndition. The dam has a size classification of intermediate and a hazard classification of low. The test flood is the ti... good condition. However, water passing over the spillway limited the inspection of the spillway. The dam has a size classification of intermediate...hydrologic and hydraulic assumptions. The dam is generally in good condition. However, it is recommended that the owner repair the drawdown outlet, and
Safety assessment of discharge chute isolation barrier preparation and installation. Revision 1
DOE Office of Scientific and Technical Information (OSTI.GOV)
Meichle, R.H.
1994-10-10
This revision responds to RL comments and increases the discussion of the ``effective hazard categorization`` and the readiness review basis. The safety assessment is made for the activities for the preparation and installation of the discharge chute isolation barriers. The safety assessment includes a hazard assessment and comparison of potential accidents/events to those addressed by the current safety basis documentation. No significant hazards were identified. An evaluation against the USQ evaluation questions were made and the determination made that the activities do not represent a USQ. Hazard categorization techniques were used to provide a basis for readiness review classification.
Fuel Type Classification and Fuel Loading in Central Interior, Korea: Uiseong-Gun
Myoung Soo Won; Kyo Sang Koo; Myung Bo Lee; Si Young Lee
2006-01-01
The objective of this study is classification of fuel type and calculation of fuel loading to assess forest fire hazard by fuel characteristics at Uiseong-gun, Gyeongbuk located in the central interior of Korea. A database was constructed of eight factors such as forest type and topography using ArcGIS 9.1 GIS programs. An on-site survey was conducted for investigating...
NASA Technical Reports Server (NTRS)
Farrell, W. M.; Desch, M. D.; Marshall, J. R.; Delory, G. T.; Kolecki, J. C.; Hillard, G. B.; Kaiser, M. L.; Haberle, R. M.; Zent, A. P.; Luhmann, J. G.
2000-01-01
In 1999, the NASA/Human Exploration and Development of Space (HEDS) enterprise selected a number of payloads to fly to the Martian surface in an 03 opportunity (prior to the MPL loss). Part of a proposed experiment, ECHOS, was selected to specifically understand the electrical charging hazards from tribocharged dust in the ambient atmosphere, in dust devils, and in larger storms. It is expected that Martian dust storms become tribocharged much like terrestrial dust devils which can possess almost a million elementary charges per cubic centimeter. The ECHOS package features a set of instruments for measuring electric effects: a radio to detect AC electric fields radiating from discharges in the storm,a DC electric field system for sensing electrostatic fields from concentrations of charged dust grains, and a lander electrometer chain for determining the induced potential on its body and MAV (Mars Ascent Vehicle) during the passages of a charged dust storm. Given that electricity is a systemic process originating from wind-blown dust, we also proposed to correlate the electrical measurements with fundamental fluid/meteorological observations, including wind velocity and vorticity, temperature, and pressure. Triboelectricity will also affect local chemistry, and chemical-sensing devices were also considered a feature of the package. The primary HEDS objectives of the ECHOS sensing suite is to discover and monitor the natural electrical hazards associated with dust devils and storms, and determine their enviro-effectiveness on human systems. However, ECHOS also has a strong footprint in the overarching science objectives of the Mars Surveyor Program.
1985-12-01
ITASK IWORK UNIT Roo 2 DELEMENT NO. NO. NO. IACCESSION NO ~2sI DC tn 200061 1 ift E (include Security Classification) Industrit I Processes to Reduice...SCRT LSIIAINO HSPG Bes Av ia l ther editions are obsolete. I iN 1 ALSs I F1 1- Bs Available INDUSTRIAL PROCESSES TO REDUCE GENERATION OF HAZARDOUS...Defense (DOD) by CH2M HILL and PEER Consultants, Inc., for the purpose of reducing hazardous waste generation from DOD industrial processes . It is not
NASA Technical Reports Server (NTRS)
Fassnacht, P. O.
1971-01-01
A heat flux study of deflagrating pyrotechnic munitions is presented. Three tests were authorized to investigate whether heat flux measurements may be used as effective hazards evaluation criteria to determine safe quantity distances for pyrotechnics. A passive sensor study was conducted simultaneously to investigate their usefulness in recording events and conditions. It was concluded that heat flux measurements can effectively be used to evaluate hazards criteria and that passive sensors are an inexpensive tool to record certain events in the vicinity of deflagrating pyrotechnic stacks.
30 CFR 46.6 - Newly hired experienced miner training.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Instruction on the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and... health and safety aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition...
30 CFR 46.6 - Newly hired experienced miner training.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Instruction on the recognition and avoidance of electrical hazards and other hazards present at the mine, such as traffic patterns and control, mobile equipment (e.g., haul trucks and front-end loaders), and... health and safety aspects of an assigned task in paragraph (b)(4) of this section, if hazard recognition...
46 CFR 111.105-17 - Wiring methods for hazardous locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Wiring methods for hazardous locations. 111.105-17... ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-17 Wiring methods for... made with dust-tight cable entrance seals approved for the installation. [CGD 94-108, 61 FR 28284, June...
Early warning, warning or alarm systems for natural hazards? A generic classification.
NASA Astrophysics Data System (ADS)
Sättele, Martina; Bründl, Michael; Straub, Daniel
2013-04-01
Early warning, warning and alarm systems have gained popularity in recent years as cost-efficient measures for dangerous natural hazard processes such as floods, storms, rock and snow avalanches, debris flows, rock and ice falls, landslides, flash floods, glacier lake outburst floods, forest fires and even earthquakes. These systems can generate information before an event causes loss of property and life. In this way, they mainly mitigate the overall risk by reducing the presence probability of endangered objects. These systems are typically prototypes tailored to specific project needs. Despite their importance there is no recognised system classification. This contribution classifies warning and alarm systems into three classes: i) threshold systems, ii) expert systems and iii) model-based expert systems. The result is a generic classification, which takes the characteristics of the natural hazard process itself and the related monitoring possibilities into account. The choice of the monitoring parameters directly determines the system's lead time. The classification of 52 active systems moreover revealed typical system characteristics for each system class. i) Threshold systems monitor dynamic process parameters of ongoing events (e.g. water level of a debris flow) and incorporate minor lead times. They have a local geographical coverage and a predefined threshold determines if an alarm is automatically activated to warn endangered objects, authorities and system operators. ii) Expert systems monitor direct changes in the variable disposition (e.g crack opening before a rock avalanche) or trigger events (e.g. heavy rain) at a local scale before the main event starts and thus offer extended lead times. The final alarm decision incorporates human, model and organisational related factors. iii) Model-based expert systems monitor indirect changes in the variable disposition (e.g. snow temperature, height or solar radiation that influence the occurrence probability of snow avalanches) or trigger events (e.g. heavy snow fall) to predict spontaneous hazard events in advance. They encompass regional or national measuring networks and satisfy additional demands such as the standardisation of the measuring stations. The developed classification and the characteristics, which were revealed for each class, yield a valuable input to quantifying the reliability of warning and alarm systems. Importantly, this will facilitate to compare them with well-established standard mitigation measures such as dams, nets and galleries within an integrated risk management approach.
Identification of Critical Biological Parameters Affecting Gastrointestinal Absorption
1990-01-01
invention that may in any way be related thereto. Please do not request copies of this report from the Harry G. Armstrong Aerospace Medical Research...BALLINGER, Lt Col, USAF, BSC Chief, Toxic Hazards Division Harry G. Armstrong Aerospace Medical Research Laboratory UNCLASSIFIED SECURITY CLASSIFICATION OF...involved in a very large task of hazard management through its Installation Restoration Program. The pioneering efforts of the Armstrong Aerospace
Jessica E. Halofsky; Stephanie K. Hart; Miles A. Hemstrom; Joshua S. Halofsky; Morris C. Johnson
2014-01-01
Information on the effects of management activities such as fuel reduction treatments and of processes such as vegetation growth and disturbance on fire hazard can help land managers prioritize treatments across a landscape to best meet management goals. State-and-transition models (STMs) allow landscape-scale simulations that incorporate effects of succession,...
Leontaridou, Maria; Urbisch, Daniel; Kolle, Susanne N; Ott, Katharina; Mulliner, Denis S; Gabbert, Silke; Landsiedel, Robert
2017-01-01
Test methods to assess the skin sensitization potential of a substance usually use threshold criteria to dichotomize continuous experimental read-outs into yes/no conclusions. The threshold criteria are prescribed in the respective OECD test guidelines and the conclusion is used for regulatory hazard assessment, i.e., classification and labelling of the substance. We can identify a borderline range (BR) around the classification threshold within which test results are inconclusive due to a test method's biological and technical variability. We quantified BRs in the prediction models of the non-animal test methods DPRA, LuSens and h-CLAT, and of the animal test LLNA, respectively. Depending on the size of the BR, we found that between 6% and 28% of the substances in the sets tested with these methods were considered borderline. When the results of individual non-animal test methods were combined into integrated testing strategies (ITS), borderline test results of individual tests also affected the overall assessment of the skin sensitization potential of the testing strategy. This was analyzed for the 2-out-of-3 ITS: Four out of 40 substances (10%) were considered borderline. Based on our findings we propose expanding the standard binary classification of substances into "positive"/"negative" or "hazardous"/"non-hazardous" by adding a "borderline" or "inconclusive" alert for cases where test results fall within the borderline range.
30 CFR 250.1628 - Design, installation, and operation of production systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Systems (as incorporated by reference in § 250.198); (3) Electrical system information including a plan of... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as... for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2...
30 CFR 250.802 - Design, installation, and operation of surface production-safety systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... and electrical systems to be installed were approved by registered professional engineers. After these... reference as specified in § 250.198). (4) Electrical system information including the following: (i) A plan... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as...
30 CFR 250.1628 - Design, installation, and operation of production systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Systems (as incorporated by reference in § 250.198); (3) Electrical system information including a plan of... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as... for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2...
30 CFR 250.1628 - Design, installation, and operation of production systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Systems (as incorporated by reference in § 250.198); (3) Electrical system information including a plan of... Practice for Classification of Locations for Electrical Installations at Petroleum Facilities Classified as... for Electrical Installations at Petroleum Facilities Classified as Class I, Zone 0, Zone 1, and Zone 2...
Fines classification based on sensitivity to pore-fluid chemistry
Jang, Junbong; Santamarina, J. Carlos
2016-01-01
The 75-μm particle size is used to discriminate between fine and coarse grains. Further analysis of fine grains is typically based on the plasticity chart. Whereas pore-fluid-chemistry-dependent soil response is a salient and distinguishing characteristic of fine grains, pore-fluid chemistry is not addressed in current classification systems. Liquid limits obtained with electrically contrasting pore fluids (deionized water, 2-M NaCl brine, and kerosene) are combined to define the soil “electrical sensitivity.” Liquid limit and electrical sensitivity can be effectively used to classify fine grains according to their fluid-soil response into no-, low-, intermediate-, or high-plasticity fine grains of low, intermediate, or high electrical sensitivity. The proposed methodology benefits from the accumulated experience with liquid limit in the field and addresses the needs of a broader range of geotechnical engineering problems.
Chemical hazards associated with treatment of waste electrical and electronic equipment
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tsydenova, Oyuna; Bengtsson, Magnus, E-mail: bengtsson@iges.or.jp
2011-01-15
This review paper summarizes the existing knowledge on the chemical hazards associated with recycling and other end-of-life treatment options of waste electrical and electronic equipment (e-waste). The hazards arise from the presence of heavy metals (e.g., mercury, cadmium, lead, etc.), flame retardants (e.g., pentabromophenol, polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol-A (TBBPA), etc.) and other potentially harmful substances in e-waste. If improperly managed, the substances may pose significant human and environmental health risks. The review describes the potentially hazardous content of e-waste, examines the existing e-waste management practices and presents scientific data on human exposure to chemicals, workplace and environmental pollution associatedmore » with the three major e-waste management options, i.e., recycling, incineration and landfilling. The existing e-waste management practices and associated hazards are reviewed separately for developed and developing countries. Finally, based on this review, the paper identifies gaps in the existing knowledge and makes some recommendations for future research.« less
BCI federal legislative & regulatory update
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1995-02-01
Several updates on recent government actions that affect the battery industry are outlined. The National Highway Traffic Safety Administration is requesting public comments on how to regulate electric vehicles (EV) with respect to battery electrolyte spillage and electric shock hazard during crashes or rollovers, as well as during repair or maintenance. The Environmental Protection Agency (EPA) was mentioned in two actions: the monitoring rule regarding major sources of air pollution and the reccomendation of reasearch concerning hazardous air pollutants from small stationary sources. OSHA will develop a new standards planning process to ensure that the agency`s limited resources are usedmore » appropriately. This includes a list of fifty workplace hazards or issues that would warrant OSHA action.« less
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2012 CFR
2012-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2014 CFR
2014-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2013 CFR
2013-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2011 CFR
2011-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
29 CFR 1926.903 - Underground transportation of explosives.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Trucks used for the transportation of explosives underground shall have the electrical system checked weekly to detect any failures which may constitute an electrical hazard. A certification record which... powered by the truck's electrical system, shall be prohibited. (g) Explosives and blasting agents shall be...
Evaluation of Equipment Vulnerability and Potential Shock Hazards. [carbon fibers
NASA Technical Reports Server (NTRS)
Taback, I.
1980-01-01
The vulnerability of electric equipment to carbon fibers released from aircraft accidents is investigated and the parameters affecting vulnerability are discussed. The shock hazard for a hypothetical set of accidents is computed.
Optical techniques for biological triggers and identifiers
NASA Astrophysics Data System (ADS)
Grant, Bruce A. C.
2004-12-01
Optical techniques for the classification and identification of biological particles provide a number of advantages over traditional 'Wet Chemistry" methods, amongst which are speed of response and the reduction/elimination of consumables. These techniques can be employed in both 'Trigger" and 'Identifier" systems. Trigger systems monitor environmental particulates with the aim of detecting 'unusual" changes in the overall environmental composition and providing an indication of threat. At the present time there is no single optical measurement that can distinguish between benign and hostile events. Therefore, in order to distinguish between these 2 classifications, a number of different measurements must be effected and a decision made on the basis of the 'integrated" data. Smiths Detection have developed a data gathering platform capable of measuring multiple optical, physical and electrical parameters of individual airborne biological particles. The data from all these measurements are combined in a hazard classification algorithm based on Bayesian Inference techniques. Identifier systems give a greater level of information and confidence than triggers, -- although they require reagents and are therefore much more expensive to operate -- and typically take upwards of 20 minutes to respond. Ideally, in a continuous flow mode, identifier systems would respond in real-time, and identify a range of pathogens specifically and simultaneously. The results of recent development work -- carried out by Smiths Detection and its collaborators -- to develop an optical device that meets most of these requirements, and has the stretch potential to meet all of the requirements in a 3-5 year time frame will be presented. This technology enables continuous stand-alone operation for both civil and military defense applications and significant miniaturisation can be achieved with further development.
2013-07-18
are subject to damage and abrasion (figure 5). The use of an extension cord instead of fixed wiring creates the possibility of fire , electrical shock...Medical Clinic has an adjacent warehouse that is of a higher hazard and is not separated by 1-hour fire resistance rated construction. KMC 17-May...higher hazard and is not separated by 1-hour fire resistance rated construction. DynCorp NO Awaiting USG Decision DI has not received governmental
... Use flashlights or lanterns instead. Never use an electric generator or a gas or charcoal grill indoors. ... heater. Make sure that the cord of an electric space heater is not a tripping hazard but ...
46 CFR 108.177 - Electrical equipment in classified locations.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Electrical equipment in classified locations. 108.177 Section 108.177 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE... equipment in classified locations. Electrical equipment and devices installed in spaces made non-hazardous...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-41 - Battery rooms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Battery rooms. 111.105-41 Section 111.105-41 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-41 Battery rooms. Each electrical installation in a battery room...
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL... individual electrical installation in a hazardous location must comply specifically with Articles 500-505 of...
NASA Astrophysics Data System (ADS)
1982-07-01
Serious reservations about the entire classification procedure of chemical compounds present in electrical equipment environments and the precepts on which it is based are discussed. Although some tests were conducted on selected key compounds, the committee primarily considered the chemical similarity of compounds and other known flammability properties and relied heavily on the experience and intuition of its members. The committee also recommended that the NEC grouping of dusts be changed in some ways and has reclassified dusts according to the modified version of the code.
Fanghella, Paola Di Prospero; Aliberti, Ludovica Malaguti
2013-01-01
The European Union adopted regulations (EC) 1907/2006 REACH e (EC)1272/2008 CLP, to manage chemicals. REACH requires for evaluation and management of risks connected to the use of chemical substances, while o CLP provides for the classification, labelling and packagings of dangerous substances and mixtures by implementing in the EU the UN Globally Harmonised System of Classification and Labelling applying the building block approach, that is taking on board the hazard classes and categories which are close to the existing EU system in order to maintain the level of protection of human health and environment. This regulation provides also for the notification of the classification and labelling of substances to the Classification & Labelling Inventory established by the European Chemicals Agency (ECHA). Some european downstream regulations making reference to the classification criteria, as the health and safety laws at workplace, need to be adapted to these regulations.
NASA Astrophysics Data System (ADS)
Ashraf, M. A. M.; Kumar, N. S.; Yusoh, R.; Hazreek, Z. A. M.; Aziman, M.
2018-04-01
Site classification utilizing average shear wave velocity (Vs(30) up to 30 meters depth is a typical parameter. Numerous geophysical methods have been proposed for estimation of shear wave velocity by utilizing assortment of testing configuration, processing method, and inversion algorithm. Multichannel Analysis of Surface Wave (MASW) method is been rehearsed by numerous specialist and professional to geotechnical engineering for local site characterization and classification. This study aims to determine the site classification on soft and hard ground using MASW method. The subsurface classification was made utilizing National Earthquake Hazards Reduction Program (NERHP) and international Building Code (IBC) classification. Two sites are chosen to acquire the shear wave velocity which is in the state of Pulau Pinang for soft soil and Perlis for hard rock. Results recommend that MASW technique can be utilized to spatially calculate the distribution of shear wave velocity (Vs(30)) in soil and rock to characterize areas.
Comparison analysis for classification algorithm in data mining and the study of model use
NASA Astrophysics Data System (ADS)
Chen, Junde; Zhang, Defu
2018-04-01
As a key technique in data mining, classification algorithm was received extensive attention. Through an experiment of classification algorithm in UCI data set, we gave a comparison analysis method for the different algorithms and the statistical test was used here. Than that, an adaptive diagnosis model for preventive electricity stealing and leakage was given as a specific case in the paper.
NASA Astrophysics Data System (ADS)
Hossen, Jakir; Jacobs, Eddie L.; Chari, Srikant
2014-03-01
In this paper, we propose a real-time human versus animal classification technique using a pyro-electric sensor array and Hidden Markov Model. The technique starts with the variational energy functional level set segmentation technique to separate the object from background. After segmentation, we convert the segmented object to a signal by considering column-wise pixel values and then finding the wavelet coefficients of the signal. HMMs are trained to statistically model the wavelet features of individuals through an expectation-maximization learning process. Human versus animal classifications are made by evaluating a set of new wavelet feature data against the trained HMMs using the maximum-likelihood criterion. Human and animal data acquired-using a pyro-electric sensor in different terrains are used for performance evaluation of the algorithms. Failures of the computationally effective SURF feature based approach that we develop in our previous research are because of distorted images produced when the object runs very fast or if the temperature difference between target and background is not sufficient to accurately profile the object. We show that wavelet based HMMs work well for handling some of the distorted profiles in the data set. Further, HMM achieves improved classification rate over the SURF algorithm with almost the same computational time.
Yan, Fang; Xu, Kaili; Li, Deshun; Cui, Zhikai
2017-01-01
Biomass gasification stations are facing many hazard factors, therefore, it is necessary to make hazard assessment for them. In this study, a novel hazard assessment method called extended set pair analysis (ESPA) is proposed based on set pair analysis (SPA). However, the calculation of the connection degree (CD) requires the classification of hazard grades and their corresponding thresholds using SPA for the hazard assessment. In regard to the hazard assessment using ESPA, a novel calculation algorithm of the CD is worked out when hazard grades and their corresponding thresholds are unknown. Then the CD can be converted into Euclidean distance (ED) by a simple and concise calculation, and the hazard of each sample will be ranked based on the value of ED. In this paper, six biomass gasification stations are introduced to make hazard assessment using ESPA and general set pair analysis (GSPA), respectively. By the comparison of hazard assessment results obtained from ESPA and GSPA, the availability and validity of ESPA can be proved in the hazard assessment for biomass gasification stations. Meanwhile, the reasonability of ESPA is also justified by the sensitivity analysis of hazard assessment results obtained by ESPA and GSPA. PMID:28938011
Seismic Retrofit for Electric Power Systems
Romero, Natalia; Nozick, Linda K.; Dobson, Ian; ...
2015-05-01
Our paper develops a two-stage stochastic program and solution procedure to optimize the selection of seismic retrofit strategies to increase the resilience of electric power systems against earthquake hazards. The model explicitly considers the range of earthquake events that are possible and, for each, an approximation of the distribution of damage experienced. Furthermore, this is important because electric power systems are spatially distributed and so their performance is driven by the distribution of component damage. We also test this solution procedure against the nonlinear integer solver in LINGO 13 and apply the formulation and solution strategy to the Eastern Interconnection,more » where seismic hazard stems from the New Madrid seismic zone.« less
NASA Astrophysics Data System (ADS)
Koc, Gamze; Thieken, Annegret H.
2016-04-01
Despite technological development, better data and considerable efforts to reduce the impacts of natural hazards over the last two decades, natural disasters inflicted losses have caused enormous human and economic damages in Turkey. In particular earthquakes and flooding have caused enormous human and economic losses that occasionally amounted to 3 to 4% of the gross national product of Turkey (Genç, 2007). While there is a large body of literature on earthquake hazards and risks in Turkey, comparatively little is known about flood hazards and risks. Therefore, this study is aimed at investigating flood patterns, intensities and impacts, also providing an overview of the temporal and spatial distribution of flood losses by analysing different databases on disaster losses throughout Turkey. As input for more detailed event analyses, an additional aim is to retrieve the most severe flood events in the period between 1960 and 2014 from the databases. In general, data on disaster impacts are scarce in comparison to other scientific fields in natural hazard research, although the lack of reliable, consistent and comparable data is seen as a major obstacle for effective and long-term loss prevention. Currently, only a few data sets, especially the emergency events database EM-DAT (www.emdat.be) hosted and maintained by the Centre for Research on the Epidemiology of Disasters (CRED) since 1988, are publicly accessible and have become widely used to describe trends in disaster losses. However, loss data are subjected to various biases (Gall et al. 2009). Since Turkey is in the favourable position of having a distinct national disaster database since 2009, i.e. the Turkey Disaster Data Base (TABB), there is the unique opportunity to investigate flood impacts in Turkey in more detail as well as to identify biases and underlying reasons for mismatches with EM-DAT. To compare these two databases, the events of the two databases were reclassified by using the IRDR peril classification system (IRDR, 2014). Furthermore, literature, news archives and the Global Active Archive of Large Flood Events - Dartmouth Flood Observatory (floodobservatory.colorado.edu) were used to complement loss data gaps of the databases. From 1960 to 2014, EM-DAT reported 35 flood events in Turkey (26.3 % of all natural hazards events), which caused 773 fatalities (the second most destructive type of natural hazard after earthquakes) and a total economic damage of US 2.2 billion. In contrast, TABB contained 1076 flood events (8.3 % of all natural hazards events), by which 795 people died. On this basis, floods are the third most destructive type of natural hazard -after earthquakes and extreme temperatures- for human losses in Turkey. A comparison of the two databases EM-DAT and TABB reveals big mismatches of the flood data, e.g. the reported number of events, number of affected people and economic loss, differ dramatically. It is concluded that the main reason for the big differences and contradicting numbers of different natural disaster databases is lack of standardization for data collection, peril classification and database thresholds (entry criteria). Since loss data collection is gaining more and more attention, e.g. in the Sendai Framework for Disaster Risk Reduction 2015-2030 (SFDRR), the study could offer substantial insights for flood risk mitigation and adaptation studies in Turkey. References Gall, M., Borden, K., Cutter, S.L. (2009) When do losses count? Six fallacies of loss data from natural hazards. Bulletin of the American Meteorological Society, 90(6), 799-809. Genç, F.S., (2007) Türkiye'de Kentleşme ve Doǧal Afet Riskleri ile İlişkisi, TMMOB Afet Sempozyumu. IRDR (2014) IRDR Peril Classification and Hazard Glossary. Report of the Data Group in the Integrated Research on Disaster Risk. (Available at: http://www.irdrinternational.org/2014/03/28/irdr-peril-classification-and-hazard-glossary).
Solar Photovoltaic DC Systems: Basics and Safety: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
McNutt, Peter F; Sekulic, William R; Dreifuerst, Gary
Solar Photovoltaic (PV) systems are common and growing with 42.4 GW installed capacity in U.S. (almost 15 GW added in 2016). This paper will help electrical workers, and emergency responders understand the basic operating principles and hazards of PV DC arrays. We briefly discuss the following aspects of solar photovoltaic (PV) DC systems: the effects of solar radiation and temperature on output power; PV module testing standards; common system configurations; a simple PV array sizing example; NEC guidelines and other safety features; DC array commissioning, periodic maintenance and testing; arc-flash hazard potential; how electrical workers and emergency responders can andmore » do work safely around PV arrays; do moonlight and artificial lighting pose a real danger; typical safe operating procedures; and other potential DC-system hazards to be aware of. We also present some statistics on PV DC array electrical incidents and injuries. Safe PV array operation is possible with a good understanding of PV DC arrays basics and having good safe operating procedures in place.« less
International regulatory requirements for skin sensitization testing.
Daniel, Amber B; Strickland, Judy; Allen, David; Casati, Silvia; Zuang, Valérie; Barroso, João; Whelan, Maurice; Régimbald-Krnel, M J; Kojima, Hajime; Nishikawa, Akiyoshi; Park, Hye-Kyung; Lee, Jong Kwon; Kim, Tae Sung; Delgado, Isabella; Rios, Ludmila; Yang, Ying; Wang, Gangli; Kleinstreuer, Nicole
2018-06-01
Skin sensitization test data are required or considered by chemical regulation authorities around the world. These data are used to develop product hazard labeling for the protection of consumers or workers and to assess risks from exposure to skin-sensitizing chemicals. To identify opportunities for regulatory uses of non-animal replacements for skin sensitization tests, the needs and uses for skin sensitization test data must first be clarified. Thus, we reviewed skin sensitization testing requirements for seven countries or regions that are represented in the International Cooperation on Alternative Test Methods (ICATM). We noted the type of skin sensitization data required for each chemical sector and whether these data were used in a hazard classification, potency classification, or risk assessment context; the preferred tests; and whether alternative non-animal tests were acceptable. An understanding of national and regional regulatory requirements for skin sensitization testing will inform the development of ICATM's international strategy for the acceptance and implementation of non-animal alternatives to assess the health hazards and risks associated with potential skin sensitizers. Copyright © 2018 Elsevier Inc. All rights reserved.
Research on potential user identification model for electric energy substitution
NASA Astrophysics Data System (ADS)
Xia, Huaijian; Chen, Meiling; Lin, Haiying; Yang, Shuo; Miao, Bo; Zhu, Xinzhi
2018-01-01
The implementation of energy substitution plays an important role in promoting the development of energy conservation and emission reduction in china. Energy service management platform of alternative energy users based on the data in the enterprise production value, product output, coal and other energy consumption as a potential evaluation index, using principal component analysis model to simplify the formation of characteristic index, comprehensive index contains the original variables, and using fuzzy clustering model for the same industry user’s flexible classification. The comprehensive index number and user clustering classification based on constructed particle optimization neural network classification model based on the user, user can replace electric potential prediction. The results of an example show that the model can effectively predict the potential of users’ energy potential.
Personnel Safety on Electrified Railroads
DOT National Transportation Integrated Search
1980-06-01
Potential electrical hazards to fire, police, and rescue personnel responding to emergencies on electrified railways are examined. Data on descriptions of electrical facilities, types of accidents and danger to emergency personnel, and reviews of ope...
Recommended safety guides for industrial laboratories and shops
NASA Technical Reports Server (NTRS)
Allison, W. W.
1971-01-01
Booklet provides references to 29 publications providing information on hazard control and approved safety practices. Areas include pressurized gas and vacuum systems. Guidelines are presented for safeguarding facilities where machinery, equipment, electrical devices, or hazardous chemicals are used.
Safety in the Automated Office.
ERIC Educational Resources Information Center
Graves, Pat R.; Greathouse, Lillian R.
1990-01-01
Office automation has introduced new hazards to the workplace: electrical hazards related to computer wiring, musculoskeletal problems resulting from use of computer terminals and design of work stations, and environmental concerns related to ventilation, noise levels, and office machine chemicals. (SK)
29 CFR 1910.307 - Hazardous (classified) locations.
Code of Federal Regulations, 2013 CFR
2013-07-01
...; conductor insulation, flexible cords, sealing and drainage, transformers, capacitors, switches, circuit... following are acceptable protection techniques for electric and electronic equipment in hazardous...) Nonincendive circuit. This protection technique is permitted for equipment in Class I, Division 2; Class II...
29 CFR 1910.307 - Hazardous (classified) locations.
Code of Federal Regulations, 2012 CFR
2012-07-01
...; conductor insulation, flexible cords, sealing and drainage, transformers, capacitors, switches, circuit... following are acceptable protection techniques for electric and electronic equipment in hazardous...) Nonincendive circuit. This protection technique is permitted for equipment in Class I, Division 2; Class II...
29 CFR 1910.307 - Hazardous (classified) locations.
Code of Federal Regulations, 2014 CFR
2014-07-01
...; conductor insulation, flexible cords, sealing and drainage, transformers, capacitors, switches, circuit... following are acceptable protection techniques for electric and electronic equipment in hazardous...) Nonincendive circuit. This protection technique is permitted for equipment in Class I, Division 2; Class II...
Yang, Xiaobao; Huan, Mei; Abdel-Aty, Mohamed; Peng, Yichuan; Gao, Ziyou
2015-01-01
This paper presents a hazard-based duration approach to investigate riders' waiting times, violation hazards, associated risk factors, and their differences between cyclists and electric bike riders at signalized intersections. A total of 2322 two-wheeled riders approaching the intersections during red light periods were observed in Beijing, China. The data were classified into censored and uncensored data to distinguish between safe crossing and red-light running behavior. The results indicated that the red-light crossing behavior of most riders was dependent on waiting time. They were inclined to terminate waiting behavior and run against the traffic light with the increase of waiting duration. Over half of the observed riders cannot endure 49s or longer. 25% of the riders can endure 97s or longer. Rider type, gender, waiting position, conformity tendency and crossing traffic volume were identified to have significant effects on riders' waiting times and violation hazards. Electric bike riders were found to be more sensitive to the external risk factors such as other riders' crossing behavior and crossing traffic volume than cyclists. Moreover, unobserved heterogeneity was examined in the proposed models. The finding of this paper can explain when and why cyclists and electric bike riders run against the red light at intersections. The results of this paper are useful for traffic design and management agencies to implement strategies to enhance the safety of riders. Copyright © 2014 Elsevier Ltd. All rights reserved.
Comprehension of hazard communication: effects of pictograms on safety data sheets and labels.
Boelhouwer, Eric; Davis, Jerry; Franco-Watkins, Ana; Dorris, Nathan; Lungu, Claudiu
2013-09-01
The United Nations has proposed the Globally Harmonized System (GHS) of Classification and Labelling of Chemicals to make hazard communication more uniform and to improve comprehension. Two experiments were conducted to test whether the addition of hazard and precautionary pictograms to safety data sheets and product labels would improve the transfer of information to users compared to safety data sheets and product labels containing text only. Additionally, naïve users, workers, and experts were tested to determine any potential differences among users. The effect of adding pictograms to safety data sheets and labels was statistically significant for some conditions, but was not significant across all conditions. One benefit of the addition of pictograms was that the time to respond to the survey questions decreased when the pictograms were present for both the SDS and the labels. GHS format SDS and labels do provide benefits to users, but the system will need further enhancements and modifications to continue to improve the effectiveness of hazard communication. The final rule to modify the HCS to include the Globally Harmonized System (GHS) for the Classification and Labelling of Chemicals announced by OSHA (2012b) will change the information content of every chemical SDS and label used in commerce. This study suggests that the inclusion of GHS hazard pictograms and precautionary pictograms to SDS and labels may benefit the user. Copyright © 2013 National Safety Council and Elsevier Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... that contain flammable chemicals. 5950 Coils and transformers Items containing polychlorinated... capacitors containing PCBs. 6120 Transformers: Distribution and power station Transformers containing PCBs...
Code of Federal Regulations, 2014 CFR
2014-07-01
... that contain flammable chemicals. 5950 Coils and transformers Items containing polychlorinated... capacitors containing PCBs. 6120 Transformers: Distribution and power station Transformers containing PCBs...
Code of Federal Regulations, 2013 CFR
2013-07-01
... that contain flammable chemicals. 5950 Coils and transformers Items containing polychlorinated... capacitors containing PCBs. 6120 Transformers: Distribution and power station Transformers containing PCBs...
Code of Federal Regulations, 2010 CFR
2010-07-01
... that contain flammable chemicals. 5950 Coils and transformers Items containing polychlorinated... capacitors containing PCBs. 6120 Transformers: Distribution and power station Transformers containing PCBs...
Code of Federal Regulations, 2012 CFR
2012-07-01
... that contain flammable chemicals. 5950 Coils and transformers Items containing polychlorinated... capacitors containing PCBs. 6120 Transformers: Distribution and power station Transformers containing PCBs...
Classification of breast tumour using electrical impedance and machine learning techniques.
Al Amin, Abdullah; Parvin, Shahnaj; Kadir, M A; Tahmid, Tasmia; Alam, S Kaisar; Siddique-e Rabbani, K
2014-06-01
When a breast lump is detected through palpation, mammography or ultrasonography, the final test for characterization of the tumour, whether it is malignant or benign, is biopsy. This is invasive and carries hazards associated with any surgical procedures. The present work was undertaken to study the feasibility for such characterization using non-invasive electrical impedance measurements and machine learning techniques. Because of changes in cell morphology of malignant and benign tumours, changes are expected in impedance at a fixed frequency, and versus frequency of measurement. Tetrapolar impedance measurement (TPIM) using four electrodes at the corners of a square region of sides 4 cm was used for zone localization. Data of impedance in two orthogonal directions, measured at 5 and 200 kHz from 19 subjects, and their respective slopes with frequency were subjected to machine learning procedures through the use of feature plots. These patients had single or multiple tumours of various types in one or both breasts, and four of them had malignant tumours, as diagnosed by core biopsy. Although size and depth of the tumours are expected to affect the measurements, this preliminary work ignored these effects. Selecting 12 features from the above measurements, feature plots were drawn for the 19 patients, which displayed considerable overlap between malignant and benign cases. However, based on observed qualitative trend of the measured values, when all the feature values were divided by respective ages, the two types of tumours separated out reasonably well. Using K-NN classification method the results obtained are, positive prediction value: 60%, negative prediction value: 93%, sensitivity: 75%, specificity: 87% and efficacy: 84%, which are very good for such a test on a small sample size. Study on a larger sample is expected to give confidence in this technique, and further improvement of the technique may have the ability to replace biopsy.
NASA Astrophysics Data System (ADS)
Taylor, Faith E.; Malamud, Bruce D.; Millington, James D. A.
2016-04-01
The configuration of infrastructure networks such as roads, drainage and power lines can both affect and be affected by natural hazards such as earthquakes, intense rain, wildfires and extreme temperatures. In this paper, we present and compare two methods to quantify urban topology on approximate scales of 0.0005 km2 to 10 km2 and create classifications of different 'urban textures' that relate to risk of natural hazard impact in an area. The methods we use focus on applicability in urban developing country settings, where access to high resolution and high quality data may be difficult. We use the city of Nairobi, Kenya to trial these methods. Nairobi has a population >3 million, and is a mix of informal settlements, residential and commercial development. The city and its immediate surroundings are subject to a variety of natural hazards such as floods, landslides, fires, drought, hail, heavy wind and extreme temperatures; all of these hazards can occur singly, but also have the potential for one to trigger another, thus providing a 'cascade' of hazards, or for two of the hazards to occur spatially and temporally near each other and interact. We use two measures of urban texture: (i) Street block textures, (ii) Google Earth land cover textures. Street block textures builds on the methodology of Louf and Barthelemy (2014) and uses Open Street Map data to analyse the shape, size, complexity and pattern of individual blocks of land created by fully enclosed loops of the major and minor road network of Nairobi. We find >4000 of these blocks ranging in size from approximately 0.0005 km2 to 10 km2, with approximately 5 classifications of urban texture. Google Earth land cover texture is a visual classification of homogeneous parcels of land performed in Google Earth using high-resolution airborne imagery and a qualitative criteria for each land cover type. Using the Google Earth land cover texture method, we identify >40 'urban textures' based on visual characteristics such as colour, texture, shadow and setting and have created a clear criteria for classifying an area based on its visual characteristics. These two methods for classifying urban texture in Nairobi are compared in a GIS and in the field to investigate whether there is a link between the visual appearance of an area and its network topology. From these urban textures, we may start to identify areas where (a) urban texture types may indicate a relative propensity to certain hazards and their interactions and (b) urban texture types that may increase or decrease the impact of a hazard that occurs in that area.
Salim, Agus; Tai, E Shyong; Tan, Vincent Y; Welsh, Alan H; Liew, Reginald; Naidoo, Nasheen; Wu, Yi; Yuan, Jian-Min; Koh, Woon P; van Dam, Rob M
2016-08-01
In western populations, high-sensitivity C-reactive protein (hsCRP), and to a lesser degree serum creatinine and haemoglobin A1c, predict risk of coronary heart disease (CHD). However, data on Asian populations that are increasingly affected by CHD are sparse and it is not clear whether these biomarkers can be used to improve CHD risk classification. We conducted a nested case-control study within the Singapore Chinese Health Study cohort, with incident 'hard' CHD (myocardial infarction or CHD death) as an outcome. We used data from 965 men (298 cases, 667 controls) and 528 women (143 cases, 385 controls) to examine the utility of hsCRP, serum creatinine and haemoglobin A1c in improving the prediction of CHD risk over and above traditional risk factors for CHD included in the ATP III model. For each sex, the performance of models with only traditional risk factors used in the ATP III model was compared with models with the biomarkers added using weighted Cox proportional hazards analysis. The impact of adding these biomarkers was assessed using the net reclassification improvement index. For men, loge hsCRP (hazard ratio 1.25, 95% confidence interval: 1.05; 1.49) and loge serum creatinine (hazard ratio 4.82, 95% confidence interval: 2.10; 11.04) showed statistically significantly associations with CHD risk when added to the ATP III model. We did not observe a significant association between loge haemoglobin A1c and CHD risk (hazard ratio 1.83, 95% confidence interval: 0.21; 16.06). Adding hsCRP and serum creatinine to the ATP III model improved risk classification in men with a net gain of 6.3% of cases (p-value = 0.001) being reclassified to a higher risk category, while it did not significantly reduce the accuracy of classification for non-cases. For women, squared hsCRP was borderline significantly (hazard ratio 1.01, 95% confidence interval: 1.00; 1.03) and squared serum creatinine was significantly (hazard ratio 1.81, 95% confidence interval: 1.49; 2.21) associated with CHD risk. However, the association between squared haemoglobin A1c and CHD risk was not significant (hazard ratio 1.05, 95% confidence interval: 0.99; 1.12). The addition of hsCRP and serum creatinine to the ATP III model resulted in 3.7% of future cases being reclassified to a higher risk category (p-value = 0.025), while it did not significantly reduce the accuracy of classification for non-cases. Adding hsCRP and serum creatinine, but not haemoglobin A1c, to traditional risk factors improved CHD risk prediction among non-diabetic Singaporean Chinese. The improved risk estimates will allow better identification of individuals at high risk of CHD than existing risk calculators such as the ATP III model. © The European Society of Cardiology 2016.
Bernstad, Anna; la Cour Jansen, Jes; Aspegren, Henrik
2011-03-01
Through an agreement with EEE producers, Swedish municipalities are responsible for collection of hazardous waste and waste electrical and electronic equipment (WEEE). In most Swedish municipalities, collection of these waste fractions is concentrated to waste recycling centres where households can source-separate and deposit hazardous waste and WEEE free of charge. However, the centres are often located on the outskirts of city centres and cars are needed in order to use the facilities in most cases. A full-scale experiment was performed in a residential area in southern Sweden to evaluate effects of a system for property-close source separation of hazardous waste and WEEE. After the system was introduced, results show a clear reduction in the amount of hazardous waste and WEEE disposed of incorrectly amongst residual waste or dry recyclables. The systems resulted in a source separation ratio of 70 wt% for hazardous waste and 76 wt% in the case of WEEE. Results show that households in the study area were willing to increase source separation of hazardous waste and WEEE when accessibility was improved and that this and similar collection systems can play an important role in building up increasingly sustainable solid waste management systems. Copyright © 2010 Elsevier Ltd. All rights reserved.
Odendaal, Willem; van Niekerk, Ashley; Jordaan, Esme; Seedat, Mohamed
2009-01-01
The continued high mortality and morbidity rates for unintentional childhood injuries remain a public health concern. This article reports on the influence of a home visitation programme (HVP) on household hazards associated with unintentional childhood injuries in a South African low-income setting. A randomised controlled trial (n=211 households) was conducted in a South African informal settlement. Community members were recruited and trained as paraprofessional visitors. Four intervention visits were conducted over 3 months, focusing on child development, and the prevention of burn, poison, and fall injuries. The HVP, a multi-component intervention, included educational inputs, provision of safety devices, and an implicit enforcement strategy. The intervention effect (IE) was measured with a standardised risk assessment index that compared post-intervention scores for intervention and control households. A significant reduction was observed in the hazards associated with electrical and paraffin appliances, as well as in hazards related to poisoning. Non-significant changes were observed for burn safety household practices and fall injury hazards. This study confirmed that a multi-component HVP effectively reduced household hazards associated with electrical and paraffin appliances and poisoning among children in a low-income South African setting.
Code of Federal Regulations, 2013 CFR
2013-01-01
... footnote 1 221112 Fossil Fuel Electric Power Generation See footnote 1 221113 Nuclear Electric Power... Materials and Basic Forms and Shapes Merchant Wholesalers 100 424690 Other Chemical and Allied Products...
78 FR 1162 - Cardiovascular Devices; Reclassification of External Cardiac Compressor
Federal Register 2010, 2011, 2012, 2013, 2014
2013-01-08
... safety and electromagnetic compatibility; For devices containing software, software verification... electromagnetic compatibility; For devices containing software, software verification, validation, and hazard... electrical components, appropriate analysis and testing must validate electrical safety and electromagnetic...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-09
... hospitals. 48621 Natural gas transmission. 211111 Crude petroleum and natural gas production. 211112 Natural gas liquids producers. 92811 National security. \\1\\ North American Industry Classification System...
Techniques for capturing expert knowledge - An expert systems/hypertext approach
NASA Technical Reports Server (NTRS)
Lafferty, Larry; Taylor, Greg; Schumann, Robin; Evans, Randy; Koller, Albert M., Jr.
1990-01-01
The knowledge-acquisition strategy developed for the Explosive Hazards Classification (EHC) Expert System is described in which expert systems and hypertext are combined, and broad applications are proposed. The EHC expert system is based on rapid prototyping in which primary knowledge acquisition from experts is not emphasized; the explosive hazards technical bulletin, technical guidance, and minimal interviewing are used to develop the knowledge-based system. Hypertext is used to capture the technical information with respect to four issues including procedural, materials, test, and classification issues. The hypertext display allows the integration of multiple knowlege representations such as clarifications or opinions, and thereby allows the performance of a broad range of tasks on a single machine. Among other recommendations, it is suggested that the integration of hypertext and expert systems makes the resulting synergistic system highly efficient.
SLO blind data set inversion and classification using physically complete models
NASA Astrophysics Data System (ADS)
Shamatava, I.; Shubitidze, F.; Fernández, J. P.; Barrowes, B. E.; O'Neill, K.; Grzegorczyk, T. M.; Bijamov, A.
2010-04-01
Discrimination studies carried out on TEMTADS and Metal Mapper blind data sets collected at the San Luis Obispo UXO site are presented. The data sets included four types of targets of interest: 2.36" rockets, 60-mm mortar shells, 81-mm projectiles, and 4.2" mortar items. The total parameterized normalized magnetic source (NSMS) amplitudes were used to discriminate TOI from metallic clutter and among the different hazardous UXO. First, in object's frame coordinate, the total NSMS were determined for each TOI along three orthogonal axes from the training data provided by the Strategic Environmental Research and Development Program (SERDP) along with the referred blind data sets. Then the inverted total NSMS were used to extract the time-decay classification features. Once our inversion and classification algorithms were tested on the calibration data sets then we applied the same procedure to all blind data sets. The combined NSMS and differential evolution algorithm is utilized for determine the NSMS strengths for each cell. The obtained total NSMS time-decay curves were used to extract the discrimination features and perform classification using the training data as reference. In addition, for cross validation, the inverted locations and orientations from NSMS-DE algorithm were compared against the inverted data that obtained via the magnetic field, vector and scalar potentials (HAP) method and the combined dipole and Gauss-Newton approach technique. We examined the entire time decay history of the total NSMS case-by-case for classification purposes. Also, we use different multi-class statistical classification algorithms for separating the dangerous objects from non hazardous items. The inverted targets were ranked by target ID and submitted to SERDP for independent scoring. The independent scoring results are presented.
29 CFR Appendix A to Subpart S of... - References for Further Information
Code of Federal Regulations, 2014 CFR
2014-07-01
... Safety, Health, and Environmental Training. ANSI/IEEE C2-2002 National Electrical Safety Code. ANSI K61.1.... NFPA 59-2004 Utility LP-Gas Plant Code. NFPA 70-2002 National Electrical Code. (See also NFPA 70-2005.... NMAB 353-3-1980 Classification of Combustible Dust in Accordance with the National Electrical Code. [72...
29 CFR Appendix A to Subpart S of... - References for Further Information
Code of Federal Regulations, 2011 CFR
2011-07-01
... Safety, Health, and Environmental Training. ANSI/IEEE C2-2002 National Electrical Safety Code. ANSI K61.1.... NFPA 59-2004 Utility LP-Gas Plant Code. NFPA 70-2002 National Electrical Code. (See also NFPA 70-2005.... NMAB 353-3-1980 Classification of Combustible Dust in Accordance with the National Electrical Code. [72...
29 CFR Appendix A to Subpart S of... - References for Further Information
Code of Federal Regulations, 2012 CFR
2012-07-01
... Safety, Health, and Environmental Training. ANSI/IEEE C2-2002 National Electrical Safety Code. ANSI K61.1.... NFPA 59-2004 Utility LP-Gas Plant Code. NFPA 70-2002 National Electrical Code. (See also NFPA 70-2005.... NMAB 353-3-1980 Classification of Combustible Dust in Accordance with the National Electrical Code. [72...
29 CFR Appendix A to Subpart S of... - References for Further Information
Code of Federal Regulations, 2013 CFR
2013-07-01
... Safety, Health, and Environmental Training. ANSI/IEEE C2-2002 National Electrical Safety Code. ANSI K61.1.... NFPA 59-2004 Utility LP-Gas Plant Code. NFPA 70-2002 National Electrical Code. (See also NFPA 70-2005.... NMAB 353-3-1980 Classification of Combustible Dust in Accordance with the National Electrical Code. [72...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-19
... Coal- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil... Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial... before March 1, 2005, means a 24-hour period during which fossil fuel is combusted in a steam-generating...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-04-28
...-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired... Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial... copy form. The hearing schedules, including lists of speakers, will be posted on EPA's Web Sites http...
NASA Technical Reports Server (NTRS)
1961-01-01
The nature of the potential fuel tank vent fire and explosion hazard is discussed in relation to present vent exit design practice, available knowledge of atmospheric electricity as a source of ignition energy, and the vent system vapor space environment. Flammable mixtures and possible ignition sources may occur simultaneously as a rare phenomena according to existing knowledge. There is a need to extend the state of science in order to make possible vent design which is aimed specifically at minimizing fire and explosion hazards.
Electric Trees and Pond Creatures.
ERIC Educational Resources Information Center
Weaver, Helen; Hounshell, Paul B.
1978-01-01
Two learning activities are presented to develop observation and classification skills at the elementary level. The first is an electric box that associates tree names with leaf and bark specimens, and the second is a pond water observation and slide preparation activity. (BB)
Earth based approaches to enhancing the health and safety of space operations
NASA Technical Reports Server (NTRS)
Koller, A. M., Jr.
1985-01-01
This paper provides an overview of the current state of our earth based knowledge of space safety hazards; identification of several key areas of concern for space operations; and proposed approaches to providing technology enhancement and information needed to improve the health and safety to those conducting space operations. Included are a review of the identified hazards for space oeprations by hazard classification; a summarization of the information currently available on space experiences and an assessment of potential hazards for long duration spaceflight; a discussion of potential failure modes and their significance for Space Station work: and an assessment of current work which indicates additional research and experimentation which can only be accomplished in actual space missions.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-01
...- and Oil-Fired Electric Utility Steam Generating Units and Standards of Performance for Fossil-Fuel... Performance for Fossil-Fuel- Fired Electric Utility, Industrial-Commercial-Institutional, and Small Industrial...
NASA Astrophysics Data System (ADS)
Wood, N. J.; Spielman, S.
2012-12-01
Near-field tsunami hazards are credible threats to many coastal communities throughout the world. Along the U.S. Pacific Northwest coast, low-lying areas could be inundated by a series of catastrophic tsunamis that begin to arrive in a matter of minutes following a major Cascadia subduction zone (CSZ) earthquake. Previous research has documented the residents, employees, tourists at public venues, customers at local businesses, and vulnerable populations at dependent-care facilities that are in CSZ-related tsunami-prone areas of northern California, Oregon, and the open-ocean coast of Washington. Community inventories of demographic attributes and other characteristics of the at-risk population have helped emergency managers to develop preparedness and outreach efforts. Although useful for distinct risk-reduction issues, these data can be difficult to fully appreciate holistically given the large number of community attributes. This presentation summarizes analytical efforts to classify communities with similar characteristics of community exposure to tsunami hazards. This work builds on past State-focused inventories of community exposure to CSZ-related tsunami hazards in northern California, Oregon, and Washington. Attributes used in the classification, or cluster analysis, fall into several categories, including demography of residents, spatial extent of the developed footprint based on mid-resolution land cover data, distribution of the local workforce, and the number and type of public venues, dependent-care facilities, and community-support businesses. As we were unsure of the number of different types of communities, we used an unsupervised-model-based clustering algorithm and a v-fold, cross-validation procedure (v=50) to identify the appropriate number of community types. Ultimately we selected class solutions that provided the appropriate balance between parsimony and model fit. The goal of the exposure classification is to provide emergency managers with a general sense of the types of communities in tsunami hazard zones based on similar exposure characteristics instead of only providing an exhaustive list of attributes for individual communities. This community-exposure classification scheme can be then used to target and prioritize risk-reduction efforts that address common issues across multiple communities, instead of community-specific efforts. Examples include risk-reduction efforts that focus on similar demographic attributes of the at-risk population or on the type of service populations that dominate tsunami-prone areas. The presentation will include a discussion of the utility of proposed place classifications to support regional preparedness and outreach efforts.
SUPERFUND TREATABILITY CLEARINGHOUSE ...
This newsletter reports on the Huber Technology Groups (HTG) high temperature advanced hazardous waste treatment technology capable of very high destruction and removal efficiencies of various hazardous wastes. This newsletter addresses the destruction of PCBs in an EPA certification test of the HTG Advanced Electric Reactor. provide information
NASA Astrophysics Data System (ADS)
Love, J. J.
2016-12-01
Magnetic-storm induction of geoelectric fields in the Earth's electrically conducting crust, lithosphere, mantle, and ocean can interfere with the operations of electric-power grid systems. The future occurrence of an extremely intense magnetic storm might even result in continental-scale failure of electric-power distribution. Such an event would entail significant deleterious consequence for the economy and international security. Building on a project established by the President's National Science and Technology Council and the Office of Science and Technology Policy for assessing space-weather induction hazards, we develop a series of geoelectric hazard maps. These are constructed using an empirical parameterization of induction: local estimates of Earth-surface impedance, obtained from EarthScope and USGS magnetotelluric survey data, are convolved with latitude-dependent statistical maps of extreme-value geomagnetic activity, obtained from decades magnetic observatory data. Geoelectric hazard maps are constructed for both north-south and east-west geomagnetic variation, and for both 240-s and 1200-s sinusoidal variation -- periods of interest to the power-grid industry. The maps cover about half of the continental United States. They depict the threshold level that geoelectric amplitude can be expected to exceed, on average, once per century at discrete geographic sites in response to extreme-intensity geomagnetic activity. Of the regions where magnetotelluric data are available, the greatest induction hazards are found in Minnesota, Wisconsin, and Iowa - this being the result of both high-latitude geomagntic activity and complex subsurface conductivity structure. At some sites in the continental United States, once-per-century geoelectric amplitudes can exceed the 1.7 V/km realized in Quebec during the March 1989 storm. This work highlights the importance of geophysical surveys and ground-level monitoring data for assessing space-weather induction hazards.
Multi-Hazard Interactions in Guatemala
NASA Astrophysics Data System (ADS)
Gill, Joel; Malamud, Bruce D.
2017-04-01
In this paper, we combine physical and social science approaches to develop a multi-scale regional framework for natural hazard interactions in Guatemala. The identification and characterisation of natural hazard interactions is an important input for comprehensive multi-hazard approaches to disaster risk reduction at a regional level. We use five transdisciplinary evidence sources to organise and populate our framework: (i) internationally-accessible literature; (ii) civil protection bulletins; (iii) field observations; (iv) stakeholder interviews (hazard and civil protection professionals); and (v) stakeholder workshop results. These five evidence sources are synthesised to determine an appropriate natural hazard classification scheme for Guatemala (6 hazard groups, 19 hazard types, and 37 hazard sub-types). For a national spatial extent (Guatemala), we construct and populate a "21×21" hazard interaction matrix, identifying 49 possible interactions between 21 hazard types. For a sub-national spatial extent (Southern Highlands, Guatemala), we construct and populate a "33×33" hazard interaction matrix, identifying 112 possible interactions between 33 hazard sub-types. Evidence sources are also used to constrain anthropogenic processes that could trigger natural hazards in Guatemala, and characterise possible networks of natural hazard interactions (cascades). The outcomes of this approach are among the most comprehensive interaction frameworks for national and sub-national spatial scales in the published literature. These can be used to support disaster risk reduction and civil protection professionals in better understanding natural hazards and potential disasters at a regional scale.
30 CFR 77.1304 - Blasting agents; special provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... connection with pneumatic loading machines shall be of the semiconductive type, having a total resistance low... electric currents to a safe level. Wire-countered hose shall not be used because of the potential hazard from stray electric currents. ...
30 CFR 77.1304 - Blasting agents; special provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... connection with pneumatic loading machines shall be of the semiconductive type, having a total resistance low... electric currents to a safe level. Wire-countered hose shall not be used because of the potential hazard from stray electric currents. ...
Hazardous Waste Cleanup: General Electric - Auburn Plant in Auburn, New York
GE purchased the property at Genesee Street in 1951 and constructed a manufacturing plant that produced a variety of electrical components including radar equipment, printed circuit boards and high voltage semiconductors. In January 1986, Powerex, Inc.,
HAZARDOUS WASTE DECONTAMINATION WITH PLASMA REACTORS
The use of electrical energy in the form of plasma has been considered as a potentially efficient means of decontaminating hazardous waste, although to date only a few attempts have been made to do so. There are a number of relative advantages and some potential disadvantages to...
This newsletter reports on the Huber Technology Groups (HTG) high temperature advanced hazardous waste treatment technology capable of very high destruction and removal efficiencies of various hazardous wastes. This newsletter addresses the destruction of PCBs in an EPA certifi...
Determination of heavy metals and halogens in plastics from electric and electronic waste.
Dimitrakakis, Emmanouil; Janz, Alexander; Bilitewski, Bernd; Gidarakos, Evangelos
2009-10-01
The presence of hazardous substances and preparations in small waste electrical and electronic equipment (sWEEE) found in the residual household waste stream of the city of Dresden, Germany has been investigated. The content of sWEEE plastics in heavy metals and halogens is determined using handheld X-ray fluorescence analysis (HXRF), elemental analysis by means of atomic absorption spectrometry (AAS) and ion exchange chromatography (IEC). Mean value of results for heavy metals in samples (n=51) by AAS are 17.4 mg/kg for Pb, 5.7 mg/kg for Cd, 8.4 mg/kg for Cr. The mass fraction of an additive as shown by HXRF (n=161) can vary over a wide range. Precise deductions as regards sWEEE plastics content in hazardous substances and preparations cannot be made. Additional research would be expedient regarding the influence of hazardous substances to recycling processes, in particular regarding the contamination of clean fractions in the exit streams of a WEEE treatment plant. Suitable standards for calibrating HXRF for use on EEE plastics or complex electr(on)ic components do not exist and should be developed.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
46 CFR 148.01-9 - Filing of special petition for special permit.
Code of Federal Regulations, 2010 CFR
2010-10-01
... permits, and any other supporting information. (4) The chemical name, common name, hazard classification...) Unless there is a good reason for priority treatment, each proposal is considered in the order in which...
Airborne EM survey in volcanoes : Application to a volcanic hazards assessment
NASA Astrophysics Data System (ADS)
Mogi, T.
2010-12-01
Airborne electromagnetics (AEM) is a useful tool for investigating subsurface structures of volcanoes because it can survey large areas involving inaccessible areas. Disadvantages include lower accuracy and limited depth of investigation. AEM has been widely used in mineral exploration in frontier areas, and have been applying to engineering and environmental fields, particularly in studies involving active volcanoes. AEM systems typically comprise a transmitter and a receiver on an aircraft or in a towed bird, and although effective for surveying large areas, their penetration depth is limited because the distance between the transmitter and receiver is small and higher-frequency signals are used. To explore deeper structures using AEM, a semi-airborne system called GRounded Electrical source Airborne Transient ElectroMagnetics (GREATEM) has been developed. The system uses a grounded-electrical-dipole as the transmitter and generates horizontal electric fields. The GREATEM technology, first proposed by Mogi et al. (1998), has recently been improved and used in practical surveys (Mogi et al., 2009). The GREATEM survey system was developed to increase the depth of investigation possible using AEM. The method was tested in some volcanoes at 2004-2005. Here I will talk about some results of typical AEM surveys and GREATEM surveys in some volcanoes in Japan to mitigate hazards associated with volcano eruption. Geologic hazards caused by volcanic eruptions can be mitigated by a combination of prediction, preparedness and land-use control. Risk management depends on the identification of hazard zones and forecasting of eruptions. Hazard zoning involves the mapping of deposits which have formed during particular phases of volcanic activity and their extrapolation to identify the area which would be likely to suffer a similar hazard at some future time. The mapping is usually performed by surface geological surveys of volcanic deposits. Resistivity mapping by AEM is useful tool to identify each volcanic deposit on the surface and at shallower depth as well. This suggests that more efficient hazard map involving subsurface information can be supplied by AEM resistivity mapping.
30 CFR 57.4600 - Extinguishing equipment.
Code of Federal Regulations, 2010 CFR
2010-07-01
....4600 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Fire Prevention... electrically conductive extinguishing agent could create an electrical hazard, a multipurpose dry-chemical fire...
NASA Technical Reports Server (NTRS)
1971-01-01
A comprehensive test plan for determining the hazards associated with pyrotechnic manufacturing processes is presented. The rationale for each test is based on a systematic analysis of historical accounts of accidents and a detailed study of the characteristics of each manufacturing process. The most hazardous manufacturing operations have been determined to be pressing, mixing, reaming, and filling. The hazard potential of a given situation is evaluated in terms of the probabilities of initiation, communication, and transition to detonation (ICT). The characteristics which affect the ICT probabilities include the ignition mechanisms which are present either in normal or abnormal operation, the condition and properties of the pyrotechnic material, and the configuration of the processing equipment. Analytic expressions are derived which describe the physical conditions of the system, thus permitting a variety of processes to be evaluated in terms of a small number of experiments.
Hazardous Waste Cleanup: Consolidated Edison Company of NY - Indian Point 2 in Buchanan, New York
Indian Point Unit 2 is a nuclear-powered electricity generating plant located in the village of Buchanan, Westchester County, New York. The facility generates and stores ignitable and mixed hazardous and radioactive waste on site. On February 28, 1997, New
Favorable Decision Upholding Radioactive/Hazardous Mixed Waste Storage Civil Enforcement Policy
This page contains a copy of the U.S. Court of Appeals (District of Columbia Circuit) decision in Edison Electric Institute, et al. v. EPA, No. 91-1586, which upheld the EPA's August 29, 1991, radioactive/hazardous 'mixed waste' storage civil enforcement policy
NASA Technical Reports Server (NTRS)
Hwu, Shian U.; Kelley, James S.; Panneton, Robert B.; Arndt, G. Dickey
1995-01-01
In order to estimate the RF radiation hazards to astronauts and electronics equipment due to various Space Station transmitters, the electric fields around the various Space Station antennas are computed using the rigorous Computational Electromagnetics (CEM) techniques. The Method of Moments (MoM) was applied to the UHF and S-band low gain antennas. The Aperture Integration (AI) method and the Geometrical Theory of Diffraction (GTD) method were used to compute the electric field intensities for the S- and Ku-band high gain antennas. As a result of this study, The regions in which the electric fields exceed the specified exposure levels for the Extravehicular Mobility Unit (EMU) electronics equipment and Extravehicular Activity (EVA) astronaut are identified for various Space Station transmitters.
Virtual reality simulation for construction safety promotion.
Zhao, Dong; Lucas, Jason
2015-01-01
Safety is a critical issue for the construction industry. Literature argues that human error contributes to more than half of occupational incidents and could be directly impacted by effective training programs. This paper reviews the current safety training status in the US construction industry. Results from the review evidence the gap between the status and industry expectation on safety. To narrow this gap, this paper demonstrates the development and utilisation of a training program that is based on virtual reality (VR) simulation. The VR-based safety training program can offer a safe working environment where users can effectively rehearse tasks with electrical hazards and ultimately promote their abilities for electrical hazard cognition and intervention. Its visualisation and simulation can also remove the training barriers caused by electricity's features of invisibility and dangerousness.
DOT National Transportation Integrated Search
1991-07-01
Oregon has twelve pavement test sites that are part of the Strategic Highway Research Program (SHRP), Long Term Pavement Performance (LTPP) studies. Part of the data gathering on these sites involves vehicle weight and classification. This pilot proj...
DOT National Transportation Integrated Search
1990-05-01
Oregon has twelve sites that are part of the Strategic Highway Research Program (SHRP), Long Term Pavement Performance (LTPP) studies. Part of the data gathering on these sites involves vehicle weight and classification. This pilot project was to hel...
Thilak Krishna, Thilakam Vimal; Creusere, Charles D; Voelz, David G
2011-01-01
Polarization, a property of light that conveys information about the transverse electric field orientation, complements other attributes of electromagnetic radiation such as intensity and frequency. Using multiple passive polarimetric images, we develop an iterative, model-based approach to estimate the complex index of refraction and apply it to target classification.
Hazardous waste: cleanup and prevention
Vandas, Stephen; Cronin, Nancy L.; Farrar, Frank; Serrano, Guillermo Eliezer Ávila; Yajimovich, Oscar Efraín González; Muñoz, Aurora R.; Rivera, María del C.
1996-01-01
Our lifestyles are supported by complex Industrial activities that produce many different chemicals and chemical wastes. The Industries that produce our clothing, cars, medicines, paper, food, fuels, steel, plastics, and electric components use and discard thousands of chemicals every year. At home we may use lawn chemicals, solvents, disinfectants, cleaners, and auto products to Improve our quality of life. A chemical that presents a threat or unreasonable risk to people or the environment Is a hazardous material. When a hazardous material can no longer be used, It becomes a hazardous waste. Hazardous wastes come from a variety of sources, from both present and past activities. Impacts to human health and the environment can result from Improper handling and disposal of hazardous waste.
NASA Astrophysics Data System (ADS)
Boron, Sergiusz
2017-06-01
Operational safety of electrical machines and equipment depends, inter alia, on the hazards resulting from their use and on the scope of applied protective measures. The use of insufficient protection against existing hazards leads to reduced operational safety, particularly under fault conditions. On the other hand, excessive (in relation to existing hazards) level of protection may compromise the reliability of power supply. This paper analyses the explosion hazard created by earth faults in longwall power supply systems and evaluates existing protection equipment from the viewpoint of its protective performance, particularly in the context of explosion hazards, and also assesses its effect on the reliability of power supply.
Kononiuk, Anna D.; Karwowska, Małgorzata
The key tool used in the European Union in order to eliminate the risks associated with the consumption of potentially hazardous food is RASFF - Rapid Alert System for Food and Feed Safety. The RASFF was established to increase accountability and strengthening cooperation between states of the European Union in the field of food safety control. The aim of this study was to explore the trends and temporal and spatial distribution of notifications on food safety hazards between January 2011 and December 2015 with a special emphasis on meat and meat products on the basis of notification from RASFF. The study analyzed notifications on the annual reports of the RASFF published by the European Commission and requests added to the portal RASFF in the period 01.01.2011 - 31.12.2015 on the category of “meat and meat products (other than poultry) and “poultry meat and poultry meat products”. Analysis included detailed information on each notification, such as the classification and date, hazard category, notifying country, country origin. The most common classifications of notification were ‘alert’ and ‘border rejection’. Generally, basis of this notifications were ‘company’s own check’ and ‘official control on the market’. Pathogenic microorganisms were the most often hazard of category in which the higher number of notifications concerned with Salmonella spp. Alert notification which is the most dangerous for consumers were the most common type of classification for notifications on ‘meat and meat product’ category. The most of notifications in category ‘poultry meat and poultry meat products’ were the result of border control. Pathogenic microorganisms were the reason for the huge number of notifications in studied product categories. Many of notifications were associated with products which origin countries were outside RASFF member states.
The costs of hazardous alcohol consumption in Germany.
Effertz, Tobias; Verheyen, Frank; Linder, Roland
2017-07-01
Hazardous alcohol consumption in Germany is a main threat to health. By using insurance claim data from the German Statutory Health Insurance and a classification strategy based on ICD10 diagnoses-codes we analyzed a sample of 146,000 subjects with more than 19,000 hazardous alcohol consumers. Employing different regression models with a control function approach, we calculate life years lost due to alcohol consumption, annual direct and indirect health costs, and the burden of pain and suffering measured by the Charlson-Index and assessed pain diagnoses. Additionally, we simulate the net accumulated premium payments over expenses in the German Statutory Health Insurance and the Statutory Pension Fund for hazardous alcohol consumers from a lifecycle perspective. In total, €39.3 billion each year result from hazardous alcohol consumption with an average loss of 7 years in life expectancy. Hazardous alcohol consumers clearly do not "pay their way" in the two main German social security systems and also display a higher intangible burden according to our definitions of pain and suffering.
Improved high modulus carbon fibers. [elimination of hazards due to electrical properties
NASA Technical Reports Server (NTRS)
Ansell, G. S.; Chen, S. H.; Diffendorf, R. J.; Kim, C. M.; Lemaistre, C. W.; Lyman, C. E.; Shen, T. H.; Wang, J. J. H.
1979-01-01
Carbon fibers which are electrically insulating but still maintain the mechanical properties of the original carbon fibers were investigated. Three approaches were taken to increase the electrical resistance of carbon fibers: (1) boron nitride (BN) coatings; (2) doping of carbon fibers to alter their electrical properties; and (3) low temperature final heat treatment. The structure of carbon fibers and its effect upon properties was also studied. Results are presented.
Positive Voltage Hazard to EMU Crewman from Currents through Plasma
NASA Astrophysics Data System (ADS)
Kramer, Leonard; Hamilton, Doug; Mikatarian, Ronald; Thomas, Joseph; Koontz, Steven
2010-09-01
The International Space Station(ISS) in its transit through the ionosphere experiences a variable electrical potential between its bonded structure and the overlying ionospheric plasma. The 160 volt solar arrays on ISS are grounded negative and drive structure to negative floating potential(FP) relative to plasma. This potential is a result of the asymmetric collection properties of currents from ions and electrons moderated by geomagnetic; so called v Å~ B induction distributing an additional 20 volts both positive and negative across ISS’s main structural truss element. Since the space suit or extravehicular mobility unit(EMU) does not protect the crewperson from electrical shock, during extra vehicular activity(EVA) the person is exposed to a hazard from the potential when any of the several metallic suit penetrations come in direct contact with ISS structure. The moisture soaked garment worn by the crewperson and the large interior metal contact areas facilitate currents through the crewperson’s body. There are two hazards; Negative and Positive FP. The Negative hazard is the better known risk created by a shock hazard from arcing of anodized material on the EMU. Negative hazard has been controlled by plasma contactor units(PCU) containing a reserve of Xenon gas which is expelled from ISS. The PCU provide a ground path for the negative charge from the structure to flow to exterior plasma bringing ISS FP closer to zero. The understanding has now emerged that the operation of PCUs to protect the crewmen from negative voltage exposes him to low to moderate positive voltage(≤15V). Positive voltage is also a hazard as it focuses electrons onto exposed metal EMU penetrations completing a circuit from plasma through interior contact with the moist crewman’s body and on to ISS ground through any of several secondary isolated metal penetrations. The resulting direct current from positive voltage exposure is now identified as an electrical shock hazard. This paper describes the model of the EMU with a human body in the circuit that has been used by NASA to evaluate the low positive voltage hazard. The model utilizes the electron collection characterization from on orbit Langmuir probe data as representative of electron collection to a positive charged surface with a wide range of on orbit plasma temperature and density conditions. The data has been unified according to nonlinear theoretical temperature and density variation of the electron saturated probe current collection theory and used as a model for the electron collection at EMU surfaces. Vulnerable paths through the EMU connecting through the crewman’s body have been identified along with electrical impedance of the exposed body parts. The body impedance information is merged with the electron collection characteristics in circuit simulation software known as SPICE. The assessment shows that currents can be on the order of 20 mA for a 15 V exposure and of order 4 mA at 3V. These currents formally violate NASA protocol for electric current exposures. However the human factors associated with subjective consequences of noxious stimuli from low voltage exposure during the stressful conditions of EVA are an area of active inquiry.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-09-23
... engine and engine parts manufacturing,'' ``Motor vehicle electrical and electronic equipment... manufacturing,'' ``Other motor vehicle electrical and electronic equipment manufacturing,'' and ``All other motor vehicle parts manufacturing'' in the second column from the list of required NAICS codes for the...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
40 CFR 257.30 - Recordkeeping requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 257.30 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
IN SILICO MODELLING OF HAZARDOUS ENDPOINTS: CURRENT PROBLEMS AND PROSPECTIVES
The primary hurdles for Quantitative Structure-Activity Relationships (QSARs) to overcome their acceptance for regulatory purposes will be discussed. They include (a) the development of more mechanistic representations of chemical structure, (b) the classification of toxicity pa...
Prediction of Skin Sensitization Potency Using Machine Learning Approaches
Replacing animal tests currently used for regulatory hazard classification of skin sensitizers is one of ICCVAM’s top priorities. Accordingly, U.S. federal agency scientists are developing and evaluating computational approaches to classify substances as sensitizers or nons...
Financial statistics of major U.S. publicly owned electric utilities 1997
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-12-01
The 1997 edition of the ``Financial Statistics of Major U.S. Publicly Owned Electric Utilities`` publication presents 5 years (1993 through 1997) of summary financial data and current year detailed financial data on the major publicly owned electric utilities. The objective of the publication is to provide Federal and State governments, industry, and the general public with current and historical data that can be used for policymaking and decisionmaking purposes related to publicly owned electric utility issues. Generator (Tables 3 through 11) and nongenerator (Tables 12 through 20) summaries are presented in this publication. Five years of summary financial data aremore » provided (Tables 5 through 11 and 14 through 20). Summaries of generators for fiscal years ending June 30 and December 31, nongenerators for fiscal years ending June 30 and December 31, and summaries of all respondents are provided in Appendix C. The composite tables present aggregates of income statement and balance sheet data, as well as financial indicators. Composite tables also display electric operation and maintenance expenses, electric utility plant, number of consumers, sales of electricity, operating revenue, and electric energy account data. The primary source of publicly owned financial data is the Form EIA-412, ``Annual Report of Public Electric Utilities.`` Public electric utilities file this survey on a fiscal year basis, in conformance with their recordkeeping practices. The EIA undertook a review of the Form EIA-412 submissions to determine if alternative classifications of publicly owned electric utilities would permit the inclusion of all respondents. The review indicated that financial indicators differ most according to whether or not a publicly owned electric utility generates electricity. Therefore, the main body of the report provides summary information in generator/nongenerator classifications. 2 figs., 101 tabs.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-18
.... South Carolina Electric & Gas Company, Case No. 2-11-cv-1110-CWH (D. S. Car. May 9, 2011). The proposed...'') against South Carolina Electric & Gas Company (``SCE&G''). The claims arise from the release of hazardous..., Washington, DC 20044-7611, and should refer to United States et al. v. South Carolina Electric & Gas Company...
Hazardous Waste Cleanup: General Electric – Main Plant Site in Schenectady, New York
GE purchased the property at Genesee Street in 1951 and constructed a manufacturing plant that produced a variety of electrical components including radar equipment, printed circuit boards and high voltage semiconductors. In January 1986, Powerex, Inc., ac
Environmental Cost of Electric Power, A Scientists' Institute for Public Information Workbook.
ERIC Educational Resources Information Center
Abrahamson, Dean E.
Analyzed are the environmental and health hazards associated with different forms of power production: nuclear power plants, fossil fuel plants, and hydroelectric plants. Data are given relating to chemical pollution, thermal pollution, radioactive hazards and geological and geographical effects. Problems of setting standards, and criteria which…
Risk is the combination of hazard and exposure. Risk characterization at UST release sites has traditionally emphasized hazard (presence of residual fuel) with little attention to exposure. Exposure characterization often limited to a one-dimensional model such as the RBCA equa...
29 CFR 1926.407 - Hazardous (classified) locations.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Electrical Code, lists or defines hazardous gases, vapors, and dusts by “Groups” characterized by their... the class, group, and operating temperature or temperature range, based on operation in a 40-degree C... be marked to indicate the group. (C) Fixed general-purpose equipment in Class I locations, other than...
29 CFR 1926.407 - Hazardous (classified) locations.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Electrical Code, lists or defines hazardous gases, vapors, and dusts by “Groups” characterized by their... the class, group, and operating temperature or temperature range, based on operation in a 40-degree C... be marked to indicate the group. (C) Fixed general-purpose equipment in Class I locations, other than...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2010 CFR
2010-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2011 CFR
2011-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2012 CFR
2012-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2014 CFR
2014-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
46 CFR 111.70-3 - Motor controllers and motor-control centers.
Code of Federal Regulations, 2013 CFR
2013-10-01
... pump, elevator, steering gear, or auxiliary that is vital to the vessel's propulsion system, except a... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Motor Circuits, Controllers, and Protection § 111.70-3 Motor... operation is not hazardous. If automatic restart is hazardous, the motor controller must have low-voltage...
Approach to the assessment of the hazard. [fire released carbon fiber electrical effects
NASA Technical Reports Server (NTRS)
Huston, R. J.
1980-01-01
An overview of the carbon fiber hazard assessment is presented. The potential risk to the civil sector associated with the accidental release of carbon fibers from aircraft having composite structures was assessed along with the need for protection of civil aircraft from carbon fibers.
On the Strength and Validity of Hazard Banding.
Scheffers, Theo; Doornaert, Blandine; Berne, Nathalie; van Breukelen, Gerard; Leplay, Antoine; van Miert, Erik
2016-11-01
Hazard Banding (HB) is a process of allocating chemical substances in bands of increasing health hazard based on their hazard classifications. Recent Control Banding (CB) tools use the classifications of the United Nations Global Harmonized System (UN GHS) or the European Union Classifications, Labelling and Packaging (EU CLP) which are grouped over 5 HBs. The use of CB is growing worldwide for the risk control of substances without an Occupational Exposure Limit Value (OELV). Well-known CB-tools like HSE-COSHH Essentials, BAuA-Einfaches Maßnahmenkonzept Gefahrstoffe (EMKG), and DGUV-IFA-Spaltenmodell (IFA) use however different GHS/CLP groupings which may lead to dissimilar HBs and control regimes for individual substances. And as the choice for a CB tool seems to be determined by geography and/or local status these differences may hamper a global, aligned HSE approach. Therefore, the HB-engines of the three public CBs and an in-company (Solvay) CB called 'Occupational Exposure Banding' (S-OEB) were compared mutually and ranked in their relation with the OELV as the 'de facto' standard. This was investigated graphically and using a 5 strength indicator, statistical method. A data set of 229 substances with high-quality GHS/CLP classifications and OELVs was used. HB concentration ranges, as linked to S-OEB and COSHH, were validated against the corresponding OELV distributions. The four HB-engines allocate between 23 and 64% of the 229 substances in the same bands. The remaining substances differ at least one band, with IFA placing more substances in a higher hazard band, EMKG doing the opposite and COSHH and S-OEB in between. The overall strength scores of S-OEB, IFA, and EMGK HB-engines are higher than COSHH, with S-OEB having the highest overall strength score. The lower ends of the concentration ranges defined for the 3 'highest' hazard bands of S-OEB were in good agreement with the 10 th percentiles of the corresponding OELV distributions obtained from the substance data set. The lower ends of the COSHH concentration ranges comply with the 10 th percentiles of the COSHH OELV distributions for dust/aerosol but not for vapour/gas substances. Both the S-OEB and COSHH concentration ranges underestimate the overall width of the OELV distributions that can span 2-3 orders of magnitude. As the performance of the S-OEB HB-engine meets our criteria of being at least as good as the public engines, it will be used as a standard within Solvay's global operations. In addition, the method described here to evaluate the strength of HB-engines and the validity of their corresponding concentration ranges is a useful tool enabling further developments and worldwide alignment of HB. © The Author 2016. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
1998-07-01
This Necessary and Sufficient (N and S) set of standards is for Other Industrial, Radiological, and Non-Radiological Hazard Facilities at Oak Ridge National Laboratory (ORNL). These facility classifications are based on a laboratory-wide approach to classify facilities by hazard category. An analysis of the hazards associated with the facilities at ORNL was conducted in 1993. To identify standards appropriate for these Other Industrial, Radiological, and Non-Radiological Hazard Facilities, the activities conducted in these facilities were assessed, and the hazards associated with the activities were identified. A preliminary hazards list was distributed to all ORNL organizations. The hazards identified in priormore » hazard analyses are contained in the list, and a category of other was provided in each general hazard area. A workshop to assist organizations in properly completing the list was held. Completed hazard screening lists were compiled for each ORNL division, and a master list was compiled for all Other Industrial, Radiological Hazard, and Non-Radiological facilities and activities. The master list was compared against the results of prior hazard analyses by research and development and environment, safety, and health personnel to ensure completeness. This list, which served as a basis for identifying applicable environment, safety, and health standards, appears in Appendix A.« less
Arnone, Mario; Koppisch, Dorothea; Smola, Thomas; Gabriel, Stefan; Verbist, Koen; Visser, Remco
2015-10-01
Many control banding tools use hazard banding in risk assessments for the occupational handling of hazardous substances. The outcome of these assessments can be combined with advice for the required risk management measures (RMMs). The Globally Harmonised System of Classification and Labelling of Chemicals (GHS) has resulted in a change in the hazard communication elements, i.e. Hazard (H) statements instead of Risk-phrases. Hazard banding schemes that depend on the old form of safety information have to be adapted to the new rules. The purpose of this publication is to outline the rationales for the assignment of hazard bands to H statements under the GHS. Based on this, this publication proposes a hazard banding scheme that uses the information from the safety data sheets as the basis for assignment. The assignment of hazard bands tiered according to the severity of the underlying hazards supports the important principle of substitution. Additionally, the set of assignment rules permits an exposure-route-specific assignment of hazard bands, which is necessary for the proposed route-specific RMMs. Ideally, all control banding tools should apply the same assignment rules. This GHS-compliant hazard banding scheme can hopefully help to establish a unified hazard banding strategy in the various control banding tools. Copyright © 2015 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Bateman, M.; Mach, D.; Lewis, S.; Dye, J.; Defer, E.; Grainger, C.; Willis, P.; Christian, H.; Merceret, F.
2003-12-01
Airborne measurements of electric fields and particle microphysics were made during a field program at NASA's Kennedy Space Center. The aircraft, a Cessna Citation II jet operated by the University of North Dakota, carried six rotating-vane style electric field mills, several microphysics instruments, and thermodynamic instruments. In addition to the aircraft measurements, we also have data from both the Eastern Test Range WSR-74C (Patrick AFB) and the U.S. National Weather Service WSR-88D radars (primarily Melbourne, FL). One specific goal of this program was to try to develop a radar-based rule for estimating the hazard that an in-cloud electric field would present to a vehicle launched into the cloud. Based on past experience, and our desire to quantify the mixed-phase region of the cloud in question, we have assessed several algorithms for integrating radar reflectivity data in and above the mixed-phase region as a proxy for electric field. A successful radar proxy is one that can accurately predict the presence or absence of significant electric fields. We have compared various proxies with the measured in-cloud electric field strength in an attempt to develop a radar rule for assessing launch hazard. Assessment of the best proxy is presented.
Hosseini, Monireh; Monazzam, Mohammad Reza; Farhang Matin, Laleh; Khosroabadi, Hossein
2015-05-01
Electromagnetic fields in recent years have been discussed as one of the occupational hazards at workplaces. Hence, control and assessment of these physical factors is very important to protect and promote the health of employees. The present study was conducted to determine hazard zones based on assessment of extremely low-frequency magnetic fields at electric substations of a petrochemical complex in southern Iran, using the single-axis HI-3604 device. In measurement of electromagnetic fields by the single-axis HI-3604 device, the sensor screen should be oriented in a way to be perpendicular to the field lines. Therefore, in places where power lines are located in different directions, it is required to keep the device towards three axes of x, y, and z. For further precision, the measurements should be repeated along each of the three axes. In this research, magnetic field was measured, for the first time, in three axes of x, y, and z whose resultant value was considered as the value of magnetic field. Measurements were done based on IEEE std 644-1994. Further, the spatial changes of the magnetic field surrounding electric substations were stimulated using MATLAB software. The obtained results indicated that the maximum magnetic flux density was 49.90 μT recorded from boiler substation, while the minimum magnetic flux density of 0.02 μT was measured at the control room of the complex. As the stimulation results suggest, the spaces around incoming panels, transformers, and cables were recognized as hazardous zones of indoor electric substations. Considering the health effects of chronic exposure to magnetic fields, it would be possible to minimize exposure to these contaminants at workplaces by identification of risky zones and observation of protective considerations.
An overview of natural hazard impacts to railways and urban transportation systems
NASA Astrophysics Data System (ADS)
Bíl, Michal; Nezval, Vojtěch; Bílová, Martina; Andrášik, Richard; Kubeček, Jan
2017-04-01
We present an overview and two case studies of natural hazard impacts on rail transportation systems in the Czech Republic. Flooding, landsliding, heavy snowfall, windstorms and glaze (black ice) are the most common natural processes which occur in this region. Whereas flooding and landsliding usually cause direct damage to the transportation infrastructure, other hazards predominantly cause indirect losses. Railway and urban tramline networks are almost fully dependent on electricity which is provided by a system of overhead lines (electric lines above the tracks). These lines are extremely susceptible to formation of glaze which blocks conduction of electric current. A December 2014 glaze event caused significant indirect losses in the largest Czech cities and railways due to the above-mentioned process. Details of this event will be provided during the presentation. Windstorms usually cause tree falls which can affect overhead lines and physically block railway tracks. Approximately 30 % of the Czech railway network is closer than 50 m from the nearest forest. This presents significant potential for transport interruption due to falling trees. Complicated legal relations among the owners of the plots of land along railways, the environment (full-grown trees and related habitat), and the railway administrator are behind many traffic interruptions due to falling trees. We have registered 2040 tree falls between 2012 and 2015 on the railway network. A model of the fallen tree hazard was created for the entire Czech railway network. Both above-mentioned case studies provide illustrative examples of the increased fragility of the modern transportation systems which fully rely on electricity. Natural processes with a low destructive power are thereby able to cause network wide service cut-offs.
46 CFR 111.105-1 - Applicability; definition.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Applicability; definition. 111.105-1 Section 111.105-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-1 Applicability; definition. This subpart applies to...
46 CFR 111.105-1 - Applicability; definition.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Applicability; definition. 111.105-1 Section 111.105-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-1 Applicability; definition. This subpart applies to...
CONTROL OF MERCURY EMISSIONS FROM COAL-FIRED ELECTRIC UTILITY BOILERS: INTERIM REPORT
The report provides additional information on mercury (Hg) emissions control following the release of "Study of Hazardous Air Pollutant Emissions from Electric Utility Steam Generating Units--Final Report to Congress" in February 1998. Chapters 1-3 describe EPA's December 2000 de...
A study of some features of ac and dc electric power systems for a space station
NASA Technical Reports Server (NTRS)
Hanania, J. I.
1983-01-01
This study analyzes certain selected topics in rival dc and high frequency ac electric power systems for a Space Station. The interaction between the Space Station and the plasma environment is analyzed, leading to a limit on the voltage for the solar array and a potential problem with resonance coupling at high frequencies. Certain problems are pointed out in the concept of a rotary transformer, and further development work is indicated in connection with dc circuit switching, special design of a transmission conductor for the ac system, and electric motors. The question of electric shock hazards, particularly at high frequency, is also explored. and a problem with reduced skin resistance and therefore increased hazard with high frequency ac is pointed out. The study concludes with a comparison of the main advantages and disadvantages of the two rival systems, and it is suggested that the choice between the two should be made after further studies and development work are completed.
40 CFR 257.27 - Selection of remedy.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 257.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
40 CFR 257.25 - Assessment monitoring program.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 257.25 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
Code of Federal Regulations, 2010 CFR
2010-10-01
... TRANSPORTATION RAILROAD ACCIDENTS/INCIDENTS: REPORTS CLASSIFICATION, AND INVESTIGATIONS § 225.1 Purpose. The... information for determining comparative trends of railroad safety and to develop hazard elimination and risk... accident/incident and injury/illness reports filed with FRA under this part, for accidents/incidents and...
40 CFR 257.27 - Selection of remedy.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 257.27 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste Disposal Units...
40 CFR 257.10-257.12 - [Reserved
Code of Federal Regulations, 2010 CFR
2010-07-01
....10-257.12 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) SOLID WASTES CRITERIA FOR CLASSIFICATION OF SOLID WASTE DISPOSAL FACILITIES AND PRACTICES Disposal Standards for the Receipt of Conditionally Exempt Small Quantity Generator (CESQG) Wastes at Non-Municipal Non-Hazardous Waste...
75 FR 68849 - Privacy Act of 1974: System of Records
Federal Register 2010, 2011, 2012, 2013, 2014
2010-11-09
... processing of personal information is conducted within established FAA computer security regulations. A risk... SECURITY CLASSIFICATION: Sensitive, unclassified SYSTEM LOCATION: Federal Aviation Administration (FAA... Enforcement Centers of the Drug Abatement Division; Office of Security and Hazardous Materials; Flight...
Wolters, Mark A; Dean, C B
2017-01-01
Remote sensing images from Earth-orbiting satellites are a potentially rich data source for monitoring and cataloguing atmospheric health hazards that cover large geographic regions. A method is proposed for classifying such images into hazard and nonhazard regions using the autologistic regression model, which may be viewed as a spatial extension of logistic regression. The method includes a novel and simple approach to parameter estimation that makes it well suited to handling the large and high-dimensional datasets arising from satellite-borne instruments. The methodology is demonstrated on both simulated images and a real application to the identification of forest fire smoke.
JANNAF 17th Propulsion Systems Hazards Subcommittee Meeting. Volume 1
NASA Technical Reports Server (NTRS)
Cocchiaro, James E. (Editor); Gannaway, Mary T. (Editor); Rognan, Melanie (Editor)
1998-01-01
Volume 1, the first of two volumes is a compilation of 16 unclassified/unlimited technical papers presented at the 17th meeting of the Joint Army-Navy-NASA-Air Force (JANNAF) Propulsion Systems Hazards Subcommittee (PSHS) held jointly with the 35th Combustion Subcommittee (CS) and Airbreathing Propulsion Subcommittee (APS). The meeting was held on 7 - 11 December 1998 at Raytheon Systems Company and the Marriott Hotel, Tucson, AZ. Topics covered include projectile and shaped charge jet impact vulnerability of munitions; thermal decomposition and cookoff behavior of energetic materials; damage and hot spot initiation mechanisms with energetic materials; detonation phenomena of solid energetic materials; and hazard classification, insensitive munitions, and propulsion systems safety.
NASA Technical Reports Server (NTRS)
Ramohalli, K.
1980-01-01
Attempts to alleviate carbon-fiber-composite electrical hazards during airplane crash fires through fiber gasification are described. Thermogravimetric and differential scanning calorimetric experiments found several catalysts that caused fibers to combust when composites were exposed to test fires. Composites were tested in the 'Burn-Bang' apparatus and in high voltage electrical detection grid apparatus. In a standard three minute burn test modified composites released no fibers, while state-of-the-art composites released several hundred fiber fragments. Expected service life with and without catalytic modification was studied and electron microscopy and X-ray microanalysis furnished physical appearance and chemical composition data. An acrylic acid polymer fiber coating was developed that wet the carbon fiber surface uniformly with the catalyst, providing a marked contrast with the uneven coats obtained by solution-dipping.
Protection of Advanced Electrical Power Systems from Atmospheric Electromagnetic Hazards.
1981-12-01
WORDS (Continue on reverse aide if neceeary and Identify by block number) Aircraft Induced Voltages Filters Composite Structures Lightning Transients...transients on the electrical systems of aircraft with metal or composite structures. These transients will be higher than the equipment inherent hardness... composite material in skin and structure. In addition, the advanced electrical power systems used in these aircraft will contain solid state components
NASA Technical Reports Server (NTRS)
1996-01-01
Under a Lewis Research Center Small Business Innovation Research contract, SRICO, Inc. developed a fiber optic voltage sensor to measure voltage in electronic systems in spacecraft. The sensor uses glass and light to sense and transmit electricity, and is relatively safe and accurate. SRICO then commercialized the sensor for measurement of electric field and voltage in applications such as electric power systems and hazardous environments, lightning detection, and fiber optic communication systems.
NASA Technical Reports Server (NTRS)
Stone, Henry W.; Edmonds, Gary O.
1995-01-01
Remotely controlled mobile robot used to locate, characterize, identify, and eventually mitigate incidents involving hazardous-materials spills/releases. Possesses number of innovative features, allowing it to perform mission-critical functions such as opening and unlocking doors and sensing for hazardous materials. Provides safe means for locating and identifying spills and eliminates risks of injury associated with use of manned entry teams. Current version of vehicle, called HAZBOT III, also features unique mechanical and electrical design enabling vehicle to operate safely within combustible atmosphere.
Simulation Technology Laboratory Building 970 hazards assessment document
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wood, C.L.; Starr, M.D.
1994-11-01
The Department of Energy Order 5500.3A requires facility-specific hazards assessments be prepared, maintained, and used for emergency planning purposes. This hazards assessment document describes the chemical and radiological hazards associated with the Simulation Technology Laboratory, Building 970. The entire inventory was screened according to the potential airborne impact to onsite and offsite individuals. The air dispersion model, ALOHA, estimated pollutant concentrations downwind from the source of a release, taking into consideration the toxicological and physical characteristics of the release site, the atmospheric conditions, and the circumstances of the release. The greatest distances at which a postulated facility event will producemore » consequences exceeding the ERPG-2 and Early Severe Health Effects thresholds are 78 and 46 meters, respectively. The highest emergency classification is a Site Area Emergency. The Emergency Planning Zone is 100 meters.« less
Thousands of chemicals have not been characterized for their DNT potential. Due to the need for DNT hazard identification, efforts to develop screening assays for DNT potential is a high priority. Multi-well microelectrode arrays (MEA) measure the spontaneous activity of electr...
46 CFR 111.105-15 - Additional methods of protection.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Additional methods of protection. 111.105-15 Section 111.105-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-15 Additional methods of protection...
Simple circuit monitors "third wire" in ac lines
NASA Technical Reports Server (NTRS)
Kojima, T. T.; Stuck, D. E.
1980-01-01
Device detects interruption of ground connection in three-wire electrical equipment and shuts off ac power to prevent shock hazard. Silicon-controlled rectifiers detect floating ground, and deenergize optoelectric relays thereby breaking power connections. Circuit could be incorporated into hand tools, appliances, and other electrical equipment.
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...
46 CFR 111.105-5 - System integrity.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false System integrity. 111.105-5 Section 111.105-5 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-5 System integrity. In order to maintain system integrity, each...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Switches. 111.105-19 Section 111.105-19 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-19 Switches. A switch that is explosionproof or flameproof, or that...
46 CFR 111.105-3 - General requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS... reference; see 46 CFR 110.10-1), and with either Articles 500 through 505 of NFPA NEC 2002 (incorporated by... articles, and when installed fittings are approved for the specific hazardous location and the cable type...
NASA Astrophysics Data System (ADS)
Rosas-Carbajal, Marina; Komorowski, Jean-Christophe; Nicollin, Florence; Gibert, Dominique
2016-07-01
Catastrophic collapses of the flanks of stratovolcanoes constitute a major hazard threatening numerous lives in many countries. Although many such collapses occurred following the ascent of magma to the surface, many are not associated with magmatic reawakening but are triggered by a combination of forcing agents such as pore-fluid pressurization and/or mechanical weakening of the volcanic edifice often located above a low-strength detachment plane. The volume of altered rock available for collapse, the dynamics of the hydrothermal fluid reservoir and the geometry of incipient collapse failure planes are key parameters for edifice stability analysis and modelling that remain essentially hidden to current volcano monitoring techniques. Here we derive a high-resolution, three-dimensional electrical conductivity model of the La Soufrière de Guadeloupe volcano from extensive electrical tomography data. We identify several highly conductive regions in the lava dome that are associated to fluid saturated host-rock and preferential flow of highly acid hot fluids within the dome. We interpret this model together with the existing wealth of geological and geochemical data on the volcano to demonstrate the influence of the hydrothermal system dynamics on the hazards associated to collapse-prone altered volcanic edifices.
Rosas-Carbajal, Marina; Komorowski, Jean-Christophe; Nicollin, Florence; Gibert, Dominique
2016-01-01
Catastrophic collapses of the flanks of stratovolcanoes constitute a major hazard threatening numerous lives in many countries. Although many such collapses occurred following the ascent of magma to the surface, many are not associated with magmatic reawakening but are triggered by a combination of forcing agents such as pore-fluid pressurization and/or mechanical weakening of the volcanic edifice often located above a low-strength detachment plane. The volume of altered rock available for collapse, the dynamics of the hydrothermal fluid reservoir and the geometry of incipient collapse failure planes are key parameters for edifice stability analysis and modelling that remain essentially hidden to current volcano monitoring techniques. Here we derive a high-resolution, three-dimensional electrical conductivity model of the La Soufrière de Guadeloupe volcano from extensive electrical tomography data. We identify several highly conductive regions in the lava dome that are associated to fluid saturated host-rock and preferential flow of highly acid hot fluids within the dome. We interpret this model together with the existing wealth of geological and geochemical data on the volcano to demonstrate the influence of the hydrothermal system dynamics on the hazards associated to collapse-prone altered volcanic edifices. PMID:27457494
Rosas-Carbajal, Marina; Komorowski, Jean-Christophe; Nicollin, Florence; Gibert, Dominique
2016-07-26
Catastrophic collapses of the flanks of stratovolcanoes constitute a major hazard threatening numerous lives in many countries. Although many such collapses occurred following the ascent of magma to the surface, many are not associated with magmatic reawakening but are triggered by a combination of forcing agents such as pore-fluid pressurization and/or mechanical weakening of the volcanic edifice often located above a low-strength detachment plane. The volume of altered rock available for collapse, the dynamics of the hydrothermal fluid reservoir and the geometry of incipient collapse failure planes are key parameters for edifice stability analysis and modelling that remain essentially hidden to current volcano monitoring techniques. Here we derive a high-resolution, three-dimensional electrical conductivity model of the La Soufrière de Guadeloupe volcano from extensive electrical tomography data. We identify several highly conductive regions in the lava dome that are associated to fluid saturated host-rock and preferential flow of highly acid hot fluids within the dome. We interpret this model together with the existing wealth of geological and geochemical data on the volcano to demonstrate the influence of the hydrothermal system dynamics on the hazards associated to collapse-prone altered volcanic edifices.
Determining the explosion risk level and the explosion hazard area for a group of natural gas wells
NASA Astrophysics Data System (ADS)
Gligor, A.; Petrescu, V.; Deac, C.; Bibu, M.
2016-11-01
Starting from the fact that the natural gas engineering profession is generally associated with a high occupational risk, the current paper aims to help increase the safety of natural gas wells and reduce the risk of work-related accidents, as well as the occurrence of professional illnesses, by applying an assessment method that has proven its efficiency in other industrial areas in combination with a computer-aided design software. More specifically, the paper focuses on two main research directions: assessing the explosion risk for employees working at natural gas wells and indicating areas with a higher explosion hazard by using a modern software that allows their presentation in 3D. The appropriate zoning of industrial areas allows to group the various functional areas function of the probability of the occurrence of a dangerous element, such as an explosive atmosphere and subsequently it allows also to correctly select the electrical and mechanical equipment that will be used in that area, since electrical apparatuses that are otherwise found in normal work environments cannot generally be used in areas with explosion hazard, because of the risk that an electric spark, an electrostatic discharge etc. ignites the explosive atmosphere.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hennebert, Pierre, E-mail: pierre.hennebert@ineris.fr; Papin, Arnaud; Padox, Jean-Marie
Highlights: • Knowledge of wastes in substances will be necessary to assess HP1–HP15 hazard properties. • A new analytical protocol is proposed for this and tested by two service laboratories on 32 samples. • Sixty-three percentage of the samples have a satisfactory analytical balance between 90% and 110%. • Eighty-four percentage of the samples were classified identically (Seveso Directive) for their hazardousness by the two laboratories. • The method, in progress, is being normalized in France and is be proposed to CEN. - Abstract: The classification of waste as hazardous could soon be assessed in Europe using largely the hazardmore » properties of its constituents, according to the the Classification, Labelling and Packaging (CLP) regulation. Comprehensive knowledge of the component constituents of a given waste will therefore be necessary. An analytical protocol for determining waste composition is proposed, which includes using inductively coupled plasma (ICP) screening methods to identify major elements and gas chromatography/mass spectrometry (GC–MS) screening techniques to measure organic compounds. The method includes a gross or indicator measure of ‘pools’ of higher molecular weight organic substances that are taken to be less bioactive and less hazardous, and of unresolved ‘mass’ during the chromatography of volatile and semi-volatile compounds. The concentration of some elements and specific compounds that are linked to specific hazard properties and are subject to specific regulation (examples include: heavy metals, chromium(VI), cyanides, organo-halogens, and PCBs) are determined by classical quantitative analysis. To check the consistency of the analysis, the sum of the concentrations (including unresolved ‘pools’) should give a mass balance between 90% and 110%. Thirty-two laboratory samples comprising different industrial wastes (liquids and solids) were tested by two routine service laboratories, to give circa 7000 parameter results. Despite discrepancies in some parameters, a satisfactory sum of estimated or measured concentrations (analytical balance) of 90% was reached for 20 samples (63% of the overall total) during this first test exercise, with identified reasons for most of the unsatisfactory results. Regular use of this protocol (which is now included in the French legislation) has enabled service laboratories to reach a 90% mass balance for nearly all the solid samples tested, and most of liquid samples (difficulties were caused in some samples from polymers in solution and vegetable oil). The protocol is submitted to French and European normalization bodies (AFNOR and CEN) and further improvements are awaited.« less
Zhang, Sheng; Huang, Jinsheng; Yang, Baigbing; Lin, Binjie; Xu, Xinyun; Chen, Jinru; Zhao, Zhuandi; Tu, Xiaozhi; Bin, Haihua
2014-04-01
To improve the occupational health management levels in electroplating enterprises with quantitative classification measures and to provide a scientific basis for the prevention and control of occupational hazards in electroplating enterprises and the protection of workers' health. A quantitative classification table was created for the occupational health management in electroplating enterprises. The evaluation indicators included 6 items and 27 sub-items, with a total score of 100 points. Forty electroplating enterprises were selected and scored according to the quantitative classification table. These electroplating enterprises were classified into grades A, B, and C based on the scores. Among 40 electroplating enterprises, 11 (27.5%) had scores of >85 points (grade A), 23 (57.5%) had scores of 60∼85 points (grade B), and 6 (15.0%) had scores of <60 points (grade C). Quantitative classification management for electroplating enterprises is a valuable attempt, which is helpful for the supervision and management by the health department and provides an effective method for the self-management of enterprises.
Code of Federal Regulations, 2013 CFR
2013-10-01
... TRANSPORTATION RAILROAD ACCIDENTS/INCIDENTS: REPORTS CLASSIFICATION, AND INVESTIGATIONS § 225.1 Purpose. The... information for determining comparative trends of railroad safety and to develop hazard elimination and risk... to submit to it copies of accident/incident and injury/illness reports filed with FRA under this part...
Code of Federal Regulations, 2014 CFR
2014-10-01
... TRANSPORTATION RAILROAD ACCIDENTS/INCIDENTS: REPORTS CLASSIFICATION, AND INVESTIGATIONS § 225.1 Purpose. The... information for determining comparative trends of railroad safety and to develop hazard elimination and risk... to submit to it copies of accident/incident and injury/illness reports filed with FRA under this part...
Code of Federal Regulations, 2011 CFR
2011-10-01
... TRANSPORTATION RAILROAD ACCIDENTS/INCIDENTS: REPORTS CLASSIFICATION, AND INVESTIGATIONS § 225.1 Purpose. The... information for determining comparative trends of railroad safety and to develop hazard elimination and risk... to submit to it copies of accident/incident and injury/illness reports filed with FRA under this part...
Code of Federal Regulations, 2012 CFR
2012-10-01
... TRANSPORTATION RAILROAD ACCIDENTS/INCIDENTS: REPORTS CLASSIFICATION, AND INVESTIGATIONS § 225.1 Purpose. The... information for determining comparative trends of railroad safety and to develop hazard elimination and risk... to submit to it copies of accident/incident and injury/illness reports filed with FRA under this part...
On March 26, 2012, Occupational Safety and Health Administration (OSHA) modified its HCS to conform to the United Nations’ (UN) Globally Harmonized System of Classification and Labeling of Chemicals (GHS), to improve consistency and quality of information.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Nathanael J. K.; Gearhart, Jared Lee; Jones, Dean A.
Currently, much of protection planning is conducted separately for each infrastructure and hazard. Limited funding requires a balance of expenditures between terrorism and natural hazards based on potential impacts. This report documents the results of a Laboratory Directed Research & Development (LDRD) project that created a modeling framework for investment planning in interdependent infrastructures focused on multiple hazards, including terrorism. To develop this framework, three modeling elements were integrated: natural hazards, terrorism, and interdependent infrastructures. For natural hazards, a methodology was created for specifying events consistent with regional hazards. For terrorism, we modeled the terrorists actions based on assumptions regardingmore » their knowledge, goals, and target identification strategy. For infrastructures, we focused on predicting post-event performance due to specific terrorist attacks and natural hazard events, tempered by appropriate infrastructure investments. We demonstrate the utility of this framework with various examples, including protection of electric power, roadway, and hospital networks.« less
Suleiman, Abdulqadir M; Svendsen, Kristin V H
2014-10-01
Cleaning products are considered less hazardous than those used in other sectors. Suppliers and distributors are less conscientious when it comes to informing users on health risks. The aim of the study was to elaborate on the usefulness and clarity of information in the safety data sheets (SDS) for cleaning products, and considering if the use of these SDSs can be seen as a risk factor towards occupational exposure to hazardous chemicals in the sector. Safety data sheets were selected based on the risk level of the product assigned in an industrial sector scheme. 320 SDSs for cleaning products were reviewed. Constituent components found in the products over a given threshold were listed and available information thereof used to assess the perceived non-hazard consideration of the chemicals. The contents of the SDSs was generic and mostly incomplete. Safety measures and health information lacked sufficient specificity despite varying compositions and concentrations of components. There is generally incompatibility between mentioned sections on the suggested non-hazardous nature of the products and health effects. Not all substances used in these products have harmonized classifications, which makes them open to various classification of the products and the suggested safety measures. This results in different companies classifying similar products differently. Risk management measures and suggested personal protective equipment (PPEs) are given haphazardly. Physical properties relevant to risk assessment are not included. The safety data sheets are ambiguous, and they lack relevant and important information. Inadequate information and risk assessment concerning the products can lead to workers being exposed to hazardous chemicals. Underestimation of the hazard contribution of the components of the products and the insufficient, non-objective mention of appropriate control and protective measures are the major contributing elements. There is a need to test the products in order to establish health effects and product specific safety measures.
Surface water classification and monitoring using polarimetric synthetic aperture radar
NASA Astrophysics Data System (ADS)
Irwin, Katherine Elizabeth
Surface water classification using synthetic aperture radar (SAR) is an established practice for monitoring flood hazards due to the high temporal and spatial resolution it provides. Surface water change is a dynamic process that varies both spatially and temporally, and can occur on various scales resulting in significant impacts on affected areas. Small-scale flooding hazards, caused by beaver dam failure, is an example of surface water change, which can impact nearby infrastructure and ecosystems. Assessing these hazards is essential to transportation and infrastructure maintenance. With current satellite missions operating in multiple polarizations, spatio-temporal resolutions, and frequencies, a comprehensive comparison between SAR products for surface water monitoring is necessary. In this thesis, surface water extent models derived from high resolution single-polarization TerraSAR-X (TSX) data, medium resolution dual-polarization TSX data and low resolution quad-polarization RADARSAT-2 (RS-2) data are compared. There exists a compromise between acquiring SAR data with a high resolution or high information content. Multi-polarization data provides additional phase and intensity information, which makes it possible to better classify areas of flooded vegetation and wetlands. These locations are often where fluctuations in surface water occur and are essential for understanding dynamic underlying processes. However, often multi-polarized data is acquired at a low resolution, which cannot image these zones effectively. High spatial resolution, single-polarization TSX data provides the best model of open water. However, these single-polarization observations have limited information content and are affected by shadow and layover errors. This often hinders the classification of other land cover types. The dual-polarization TSX data allows for the classification of flooded vegetation, but classification is less accurate compared to the quad-polarization RS-2 data. The RS-2 data allows for the discrimination of open water, marshes/fields and forested areas. However, the RS-2 data is less applicable to small scale surface water monitoring (e.g. beaver dam failure), due to its low spatial resolution. By understanding the strengths and weaknesses of available SAR technology, an appropriate product can be chosen for a specific target application involving surface water change. This research benefits the eventual development of a space-based monitoring strategy over longer periods.
Electrical Engineering | Classification | College of Engineering & Applied
) 229-6916bsra@uwm.eduEng & Math Sciences 995 profile photo Robert Cuzner, Ph.D.Assistant ChairDepartment Chair of Electrical Engineering(414) 229-3885george@uwm.eduEng & Math Sciences 1245 profile photo Hossein Hosseini, Ph.D.ProfessorComputer Science(414) 229-5184hosseini@uwm.eduEng & Math
Code of Federal Regulations, 2010 CFR
2010-01-01
... footnote 1 221112 Fossil Fuel Electric Power Generation See footnote 1 221113 Nuclear Electric Power... 500 323115 Digital Printing 500 323116 Manifold Business Forms Printing 500 323117 Books Printing 500... 424590 Other Farm Product Raw Material Merchant Wholesalers 100 424610 Plastics Materials and Basic Forms...
Code of Federal Regulations, 2012 CFR
2012-01-01
... footnote 1 221112 Fossil Fuel Electric Power Generation See footnote 1 221113 Nuclear Electric Power... 500 323115 Digital Printing 500 323116 Manifold Business Forms Printing 500 323117 Books Printing 500... Merchant Wholesalers 100 424610 Plastics Materials and Basic Forms and Shapes Merchant Wholesalers 100...
Code of Federal Regulations, 2011 CFR
2011-01-01
... footnote 1 221112 Fossil Fuel Electric Power Generation See footnote 1 221113 Nuclear Electric Power... 500 323115 Digital Printing 500 323116 Manifold Business Forms Printing 500 323117 Books Printing 500... Merchant Wholesalers 100 424610 Plastics Materials and Basic Forms and Shapes Merchant Wholesalers 100...
30 CFR 250.114 - How must I install and operate electrical equipment?
Code of Federal Regulations, 2011 CFR
2011-07-01
... structures, and their facilities. (a) You must classify all areas according to API RP 500, Recommended... Class I, Division 1 and Division 2, or API RP 505, Recommended Practice for Classification of Locations... according to API RP 14F, Recommended Practice for Design and Installation of Electrical Systems for Fixed...
An Introduction to Electrical Breakdown in Dielectrics
1985-04-01
PROJECT TASK WORK UNIT ELEMENT NO. NO. NO. NO. 11TI TL E ’tniclude Security Classification) AN INTRODUCTION TO ELECTRICAL 1PERSONAL AUTHOR(S...find themselves working in the area without the benefit of formal coursework. inAlthough the title of the course was High Voltage Engineer- inI titled...this work , "An Introduction to Electrical Breakdown * Phenomena," because breakdown may occur at low voltages when spacecraft systems are considered
Hazardous Waste Cleanup: General Electric - Fort Edward in Fort Edward, New York
This 32-acre General Electric (GE) facility is located approximately 800 feet east of the Hudson River between the Villages of Fort Edward to the south and Hudson Falls to the north. A 200-foot-wide parcel west of the main portion of the site, between Alle
Hazardous Waste Cleanup: Caribe General Electric Product in Rio Piedras, Puerto Rico
The Caribe General Electric Product facility (GE Río Piedras) covers approximately 4 acres and is situated on the northern coastal plain in a relatively flat industrial/urban area of Río Piedras with an elevation between 20 and 40 feet above mean sea leve
Hazardous Waste Cleanup: Central Hudson Gas & Electric Corporation in Highland, New York
This site is located about five miles west of the Hudson River in Town of Lloyd, New York, Ulster County. It has operated as a vehicle and equipment storage and repair facility for an electric power transmission company since the 1950's. Both current
46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Additional requirements for vessels carrying vehicles... SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels carrying vehicles with fuel in their tanks. Each vessel...
46 CFR 111.105-39 - Additional requirements for vessels carrying vehicles with fuel in their tanks.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Additional requirements for vessels carrying vehicles... SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-39 Additional requirements for vessels carrying vehicles with fuel in their tanks. Each vessel...
Flammability control for electrical cables and connectors
NASA Technical Reports Server (NTRS)
Wick, W. O.; Buckey, D. L.
1973-01-01
Technique of covering fire-hazardous sections of electrical wiring with fireproof materials prevents fires from spreading in oxygen-enriched atmospheres and eliminates use of heavy metal enclosures. Materials used to cover potting on connectors and ground terminals are made from Teflon-coated Beta cloth and Fluorel, a nonflammable fully-saturated polymer.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-24
... Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial-Commercial- Institutional, and... Standards of Performance for Fossil-Fuel- Fired Electric Utility, Industrial-Commercial-Institutional, and...). Certain other material, such as copyrighted material, will be publicly available only in hard copy form...
46 CFR 111.106-1 - Applicability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Applicability. 111.106-1 Section 111.106-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) ELECTRICAL ENGINEERING ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations on OSVs § 111.106-1 Applicability. This subpart applies to OSVs of at least 6...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-04
... Design,'' GDC 31, ``Fracture Prevention of Reactor Coolant Pressure Boundary,'' and GDC 32, ``Inspection... Operating Company; Vogtle Electric Generating Plant, Unit Nos. 1 and 2; Notice of Consideration of Issuance of Amendment to Facility Operating License, Proposed No Significant Hazards Consideration...
18 CFR 1304.209 - Land-based structures/alterations.
Code of Federal Regulations, 2010 CFR
2010-04-01
... steps, pathways, boat launching ramps, marine railways located in the access corridor, bank... (electric, water-intake lines, etc.) may be placed within the access corridor as follows: (1) Power lines, poles, electrical panel, and wiring must be installed: (i) In a way that would not be hazardous to the...
Lightning Discharges to Aircraft and Associated Meteorological Conditions
NASA Technical Reports Server (NTRS)
Harrison, L P
1946-01-01
A summary is given of information on atmospheric electrical discharges to aircraft and associated meteorological conditions. Information is given that is designed to give a fairly comprehensive view of the underlying principles of meteorology and atmospheric electricity. Of special interest to pilots are lists of procedures of flight conduct and aircraft maintenance recommended foe avoiding or minimizing the hazards of disruptive electrical discharges and other severe conditions near thunderstorms.
1987-09-01
Evaluation Commnand &_. ADMASS Coly, 1W~., and ZIP Code ) 7b. ADDRESS (C01y, State, wid ZIP Code ) Dugwiay, Utahi 84022-5000 Aberdeen Proving Ground...Aency_________________________ 9L AoOMS(CRY, 0to, and ZIP Code ) 10. SOURCE OF FUNDING NUMBERS Hazardous Waste Environmental RLsearch Lab PROGRAM PROJECT TASK...CLASSIFICATION 0 UNO.ASSIFIEDAIJNLIMITED 0l SAME AS RPT. 03 OTIC USERS UNCLA.SSIFIED 22a. RAWE OF RESPONSIBLE INDIVIDUAL 22b TELEPHONE (Include Area Code ) I
Digital geomorphological landslide hazard mapping of the Alpago area, Italy
NASA Astrophysics Data System (ADS)
van Westen, Cees J.; Soeters, Rob; Sijmons, Koert
Large-scale geomorphological maps of mountainous areas are traditionally made using complex symbol-based legends. They can serve as excellent "geomorphological databases", from which an experienced geomorphologist can extract a large amount of information for hazard mapping. However, these maps are not designed to be used in combination with a GIS, due to their complex cartographic structure. In this paper, two methods are presented for digital geomorphological mapping at large scales using GIS and digital cartographic software. The methods are applied to an area with a complex geomorphological setting on the Borsoia catchment, located in the Alpago region, near Belluno in the Italian Alps. The GIS database set-up is presented with an overview of the data layers that have been generated and how they are interrelated. The GIS database was also converted into a paper map, using a digital cartographic package. The resulting largescale geomorphological hazard map is attached. The resulting GIS database and cartographic product can be used to analyse the hazard type and hazard degree for each polygon, and to find the reasons for the hazard classification.
14 CFR 417.111 - Launch plans.
Code of Federal Regulations, 2010 CFR
2010-01-01
... controls identified by a launch operator's ground safety analysis and implementation of the ground safety.... (ii) For each toxic propellant, any hazard controls and process constraints determined under the... classification and compatibility group as defined by part 420 of this chapter. (3) A graphic depiction of the...
78 FR 71523 - Quinclorac; Pesticide Tolerances
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-29
... pesticide manufacturer. The following list of North American Industrial Classification System (NAICS) codes....'' This includes exposure through drinking water and in residential settings, but does not include... information in support of this action. EPA has sufficient data to assess the hazards of and to make a...
40 CFR 63.650 - Gasoline loading rack provisions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 10 2011-07-01 2011-07-01 false Gasoline loading rack provisions. 63...) National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries § 63.650 Gasoline... or operator of a Group 1 gasoline loading rack classified under Standard Industrial Classification...
40 CFR 63.650 - Gasoline loading rack provisions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 10 2010-07-01 2010-07-01 false Gasoline loading rack provisions. 63...) National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries § 63.650 Gasoline... or operator of a Group 1 gasoline loading rack classified under Standard Industrial Classification...
40 CFR 63.650 - Gasoline loading rack provisions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 11 2012-07-01 2012-07-01 false Gasoline loading rack provisions. 63...) National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries § 63.650 Gasoline... or operator of a Group 1 gasoline loading rack classified under Standard Industrial Classification...
40 CFR 63.650 - Gasoline loading rack provisions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 11 2013-07-01 2013-07-01 false Gasoline loading rack provisions. 63...) National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries § 63.650 Gasoline... or operator of a Group 1 gasoline loading rack classified under Standard Industrial Classification...
40 CFR 63.650 - Gasoline loading rack provisions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 11 2014-07-01 2014-07-01 false Gasoline loading rack provisions. 63...) National Emission Standards for Hazardous Air Pollutants From Petroleum Refineries § 63.650 Gasoline... or operator of a Group 1 gasoline loading rack classified under Standard Industrial Classification...
Code of Federal Regulations, 2013 CFR
2013-10-01
... Accommodations1 Staterooms, toilet spaces, public spaces, offices, lockers, isolated storerooms, and pantries... Extinguisher and Semiportable Fire-Extinguishing Systems Space Classification (see § 95.50-5) Quantity and... fraction thereof suitable for hazards involved. Paint and lamp rooms B-II 1 outside space in vicinity of...
Code of Federal Regulations, 2012 CFR
2012-10-01
... Accommodations1 Staterooms, toilet spaces, public spaces, offices, lockers, isolated storerooms, and pantries... Extinguisher and Semiportable Fire-Extinguishing Systems Space Classification (see § 95.50-5) Quantity and... fraction thereof suitable for hazards involved. Paint and lamp rooms B-II 1 outside space in vicinity of...
Code of Federal Regulations, 2011 CFR
2011-10-01
... Accommodations1 Staterooms, toilet spaces, public spaces, offices, lockers, isolated storerooms, and pantries... Extinguisher and Semiportable Fire-Extinguishing Systems Space Classification (see § 95.50-5) Quantity and... fraction thereof suitable for hazards involved. Paint and lamp rooms B-II 1 outside space in vicinity of...
Code of Federal Regulations, 2014 CFR
2014-10-01
... Accommodations1 Staterooms, toilet spaces, public spaces, offices, lockers, isolated storerooms, and pantries... Extinguisher and Semiportable Fire-Extinguishing Systems Space Classification (see § 95.50-5) Quantity and... fraction thereof suitable for hazards involved. Paint and lamp rooms B-II 1 outside space in vicinity of...
Energy dissipation on a 4(H):1(V) stepped spillway
USDA-ARS?s Scientific Manuscript database
Many small earthen embankments are faced with inadequate spillway capacity due to filled sediment pools filled with sediment and sediment now filling flood pools. Additionally, hydrologic conditions have changed as a result of urbanization; thereby causing changes in the hazard classification of th...
Ecotoxicological characterization of hazardous wastes.
Wilke, B-M; Riepert, F; Koch, Christine; Kühne, T
2008-06-01
In Europe hazardous wastes are classified by 14 criteria including ecotoxicity (H 14). Standardized methods originally developed for chemical and soil testing were adapted for the ecotoxicological characterization of wastes including leachate and solid phase tests. A consensus on which tests should be recommended as mandatory is still missing. Up to now, only a guidance on how to proceed with the preparation of waste materials has been standardized by CEN as EN 14735. In this study, tests including higher plants, earthworms, collembolans, microorganisms, duckweed and luminescent bacteria were selected to characterize the ecotoxicological potential of a boiler slag, a dried sewage sludge, a thin sludge and a waste petrol. In general, the instructions given in EN 14735 were suitable for all wastes used. The evaluation of the different test systems by determining the LC/EC(50) or NOEC-values revealed that the collembolan reproduction and the duckweed frond numbers were the most sensitive endpoints. For a final classification and ranking of wastes the Toxicity Classification System (TCS) using EC/LC(50) values seems to be appropriate.
NASA Technical Reports Server (NTRS)
Koczo, Stefan, Jr.
2013-01-01
Safety analyses of the Traffic Aware Strategic Aircrew Requests (TASAR) Electronic Flight Bag (EFB) application are provided to establish its Failure Effects Classification which affects certification and operational approval requirements. TASAR was developed by NASA Langley Research Center to offer flight path improvement opportunities to the pilot during flight for operational benefits (e.g., reduced fuel, flight time). TASAR, using own-ship and network-enabled information concerning the flight and its environment, including weather and Air Traffic Control (ATC) system constraints, provides recommended improvements to the flight trajectory that the pilot can choose to request via Change Requests to ATC for revised clearance. This study reviews the Change Request process of requesting updates to the current clearance, examines the intended function of TASAR, and utilizes two safety assessment methods to establish the Failure Effects Classification of TASAR. Considerable attention has been given in this report to the identification of operational hazards potentially associated with TASAR.
Jamil, Majid; Sharma, Sanjeev Kumar; Singh, Rajveer
2015-01-01
This paper focuses on the detection and classification of the faults on electrical power transmission line using artificial neural networks. The three phase currents and voltages of one end are taken as inputs in the proposed scheme. The feed forward neural network along with back propagation algorithm has been employed for detection and classification of the fault for analysis of each of the three phases involved in the process. A detailed analysis with varying number of hidden layers has been performed to validate the choice of the neural network. The simulation results concluded that the present method based on the neural network is efficient in detecting and classifying the faults on transmission lines with satisfactory performances. The different faults are simulated with different parameters to check the versatility of the method. The proposed method can be extended to the Distribution network of the Power System. The various simulations and analysis of signals is done in the MATLAB(®) environment.
HAZARDS SUMMARY REPORT FOR A TWO WATT PROMETHIUM-147 FUELED THERMOELECTRIC GENERATOR
DOE Office of Scientific and Technical Information (OSTI.GOV)
None
1959-06-01
Discussions are included of the APU design, vehicle integration, Pm/sup 147/ properties, shielding requirements, hazards design criteria, statistical analysis for impact, and radiation protection. The use of Pm/sup 147/ makes possible the fabrication of an auxiliary power unit which has applications for low power space missions of <10 watts (electrical). (B.O.G.)
Toward Automated Cochlear Implant Fitting Procedures Based on Event-Related Potentials.
Finke, Mareike; Billinger, Martin; Büchner, Andreas
Cochlear implants (CIs) restore hearing to the profoundly deaf by direct electrical stimulation of the auditory nerve. To provide an optimal electrical stimulation pattern the CI must be individually fitted to each CI user. To date, CI fitting is primarily based on subjective feedback from the user. However, not all CI users are able to provide such feedback, for example, small children. This study explores the possibility of using the electroencephalogram (EEG) to objectively determine if CI users are able to hear differences in tones presented to them, which has potential applications in CI fitting or closed loop systems. Deviant and standard stimuli were presented to 12 CI users in an active auditory oddball paradigm. The EEG was recorded in two sessions and classification of the EEG data was performed with shrinkage linear discriminant analysis. Also, the impact of CI artifact removal on classification performance and the possibility to reuse a trained classifier in future sessions were evaluated. Overall, classification performance was above chance level for all participants although performance varied considerably between participants. Also, artifacts were successfully removed from the EEG without impairing classification performance. Finally, reuse of the classifier causes only a small loss in classification performance. Our data provide first evidence that EEG can be automatically classified on single-trial basis in CI users. Despite the slightly poorer classification performance over sessions, classifier and CI artifact correction appear stable over successive sessions. Thus, classifier and artifact correction weights can be reused without repeating the set-up procedure in every session, which makes the technique easier applicable. With our present data, we can show successful classification of event-related cortical potential patterns in CI users. In the future, this has the potential to objectify and automate parts of CI fitting procedures.
JANNAF 18th Propulsion Systems Hazards Subcommittee Meeting. Volume 1
NASA Technical Reports Server (NTRS)
Cocchiaro, James E. (Editor); Gannaway, Mary T. (Editor)
1999-01-01
This volume, the first of two volumes is a compilation of 18 unclassified/unlimited-distribution technical papers presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 18th Propulsion Systems Hazards Subcommittee (PSHS) meeting held jointly with the 36th Combustion Subcommittee (CS) and 24th Airbreathing Propulsion Subcommittee (APS) meetings. The meeting was held 18-21 October 1999 at NASA Kennedy Space Center and The DoubleTree Oceanfront Hotel, Cocoa Beach, Florida. Topics covered at the PSHS meeting include: shaped charge jet and kinetic energy penetrator impact vulnerability of gun propellants; thermal decomposition and cookoff behavior of energetic materials; violent reaction; detonation phenomena of solid energetic materials subjected to shock and impact stimuli; and hazard classification, insensitive munitions, and propulsion systems safety.
"Making Do" Decisions: How Home Healthcare Personnel Manage Their Exposure to Home Hazards.
Wills, Celia E; Polivka, Barbara J; Darragh, Amy; Lavender, Steven; Sommerich, Carolyn; Stredney, Donald
2016-04-01
This study describes the decision-making processes home healthcare personnel (HHP) use to manage their personal health and safety when managing hazards in client homes. A professionally diverse national sample of 68 HHP participated in individual semi-structured interviews and focus group discussions, and described their decision making and strategies for hazard management in their work environments. HHP described 353 hazard management dilemmas within 394 specifically identified hazards, which were clustered within three broader categories: electrical/fire, slip/trip/lift, and environmental exposures. HHP described multiple types of "making do" decisions for hazard management solutions in which perceived and actual resource limitations constrained response options. A majority of hazard management decisions in the broader hazards categories (72.5%, 68.5%, and 63.5%, respectively) were classifiable as less than optimal. These findings stress the need for more support of HHPs, including comprehensive training, to improve HHP decision making and hazard management strategies, especially in context of resource constraints. © The Author(s) 2015.
“Making Do” Decisions: How Home Healthcare Personnel Manage Their Exposure to Home Hazards
Wills, Celia E.; Polivka, Barbara J.; Darragh, Amy; Lavender, Steven; Sommerich, Carolyn; Stredney, Donald
2016-01-01
This study describes the decision-making processes home healthcare personnel (HHP) use to manage their personal health and safety when managing hazards in client homes. A professionally diverse national sample of 68 HHP participated in individual semi-structured interviews and focus group discussions, and described their decision making and strategies for hazard management in their work environments. HHP described 353 hazard management dilemmas within 394 specifically identified hazards, which were clustered within three broader categories: electrical/fire, slip/trip/lift, and environmental exposures. HHP described multiple types of “making do” decisions for hazard management solutions in which perceived and actual resource limitations constrained response options. A majority of hazard management decisions in the broader hazards categories (72.5%, 68.5%, and 63.5%, respectively) were classifiable as less than optimal. These findings stress the need for more support of HHPs, including comprehensive training, to improve HHP decision making and hazard management strategies, especially in context of resource constraints. PMID:26669605
Project DIPOLE WEST - Multiburst Environment (Non-Simultaneous Detonations)
1976-09-01
PAGE (WIMn Dat• Bntered) Unclassified SECURITY CLASSIFICATION OP’ THIS PAGE(ft• Data .Bnt......, 20. Abstract Purpose of the series was to obtain...HULL hydrodynamic air blast code show good correlation. UNCLASSIFIED SECUFUTY CLASSIFICATION OF THIS PA.GE(When Date Bntered) • • 1...supervision. Contributions were also made by Dr. John Dewey, University of Victoria; Mr. A. P. R. Lambert, Canadian General Electric; Mr. Charles Needham
Compressed Gas Safety for Experimental Fusion Facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lee C. Cadwallader
2004-09-01
Experimental fusion facilities present a variety of hazards to the operators and staff. There are unique or specialized hazards, including magnetic fields, cryogens, radio frequency emissions, and vacuum reservoirs. There are also more general industrial hazards, such as a wide variety of electrical power, pressurized air, and cooling water systems in use, there are crane and hoist loads, working at height, and handling compressed gas cylinders. This paper outlines the projectile hazard assoicated with compressed gas cylinders and mthods of treatment to provide for compressed gas safety. This information should be of interest to personnel at both magnetic and inertialmore » fusion experiments.« less
14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders
Code of Federal Regulations, 2011 CFR
2011-01-01
... plannersWill-carry Crew members(other than flight crew members) Will-carry General philosophy X X X X X X... General philosophy X X X X X X Limitations X X X X X X General requirements for shippers X Classification...
14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders
Code of Federal Regulations, 2013 CFR
2013-01-01
... plannersWill-carry Crew members(other than flight crew members) Will-carry General philosophy X X X X X X... General philosophy X X X X X X Limitations X X X X X X General requirements for shippers X Classification...
14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders
Code of Federal Regulations, 2014 CFR
2014-01-01
... plannersWill-carry Crew members(other than flight crew members) Will-carry General philosophy X X X X X X... General philosophy X X X X X X Limitations X X X X X X General requirements for shippers X Classification...
14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders
Code of Federal Regulations, 2012 CFR
2012-01-01
... plannersWill-carry Crew members(other than flight crew members) Will-carry General philosophy X X X X X X... General philosophy X X X X X X Limitations X X X X X X General requirements for shippers X Classification...
14 CFR Appendix O to Part 121 - Hazardous Materials Training Requirements For Certificate Holders
Code of Federal Regulations, 2010 CFR
2010-01-01
... plannersWill-carry Crew members(other than flight crew members) Will-carry General philosophy X X X X X X... General philosophy X X X X X X Limitations X X X X X X General requirements for shippers X Classification...
Dennis, J E
1997-12-01
Federal law requires that all laser products that are imported into or introduced into commerce in the United States comply with the performance standard published in the Code of Federal Regulations (CRF), Title 21, Parts 1040.10 and 1040.11, administered by the Center for Devices and Radiological Health (CDRH), US Food and Drug Administration. Although it contains somewhat different requirements for hazard classification, engineering controls and labeling, the ANSI Z136.1 standard defers to the CDRH standard. The CDRH standard became effective in August, 1976 and was amended, in 1978 and also in 1985. In the early 1990s, US experts met to formulate an approach to bring the requirements of the CDRH standard and those of the International Electrotechnical Commission (IEC) standard, IEC 825, into closer agreement in order to lower barriers to international trade and to remove any excessive compliance burdens on manufacturers. In 1993, the CDRH published, formally in the Federal Register and informally, a Notice of Intent to amend the CDRH standard. Responses to those notices have now been analyzed and informal draft amendments were distributed in 1996. This draft is now being prepared for formal issuance as a Notice of Proposed Rulemaking. Meanwhile, the IEC standard was amended in 1993 and republished as IEC 825-1; these amendments created considerable controversy since they resulted in over classification of the hazard of many products, especially light emitting diodes (LEDs) that have a large divergence and increased source dimensions. Additional amendments are now being developed to correct this problem. The CDRH has carefully monitored developments in the IEC and actively participated in its proceedings as a guide in developing its own proposal. This paper describes the major changes that are being proposed for the CDRH standard and presents some rationale for the major changes. The more significant changes include expansion of applicability to include LEDs, reduced emission durations for classification, revised measurement for hazard classification, reduced performance requirements for lower power visible radiation products, and revised requirements for medical products.
Radnoff, Diane
2013-01-01
Material Safety Data Sheets (MSDSs) are the foundation of worker right-to-know legislation for chemical hazards. Suppliers can use product test data to determine a product's classification. Alternatively, they may use evaluation and professional judgment based on test results for the product or a product, material, or substance with similar properties. While the criteria for classifying products under the new Globally Harmonized System of Classification and Labeling of Chemicals (GHS) are different, a similar process is followed. Neither the current Workplace Hazardous Materials Information System (WHMIS) nor GHS require suppliers to test their products to classify them. In this project 83 samples of products classified as flammable or combustible, representing a variety of industry sectors and product types, were collected. Flash points were measured and compared to the reported values on the MSDSs. The classifications of the products were then compared using the WHMIS and GHS criteria. The results of the study indicated that there were significant variations between the disclosed and measured flash point values. Overall, more than one-third of the products had flash points lower than that disclosed on the MSDS. In some cases, the measured values were more than 20°C lower than the disclosed values. This could potentially result in an underestimation regarding the flammability of the product so it is important for employers to understand the limitations in the information provided on MSDSs when developing safe work procedures and training programs in the workplace. Nearly one-fifth of the products were misclassified under the WHMIS system as combustible when the measured flash point indicated that they should be classified as flammable when laboratory measurement error was taken into account. While a similar number of products were misclassified using GHS criteria, the tendency appeared to be to "over-classify" (provide a hazard class that was more conservative). So the transition to GHS may potentially decrease the possibility of "under-classifying" flammable and combustible products where no test data on the product are available.
1983-08-01
ATCD-S 1 VEHICLES FORT MONROE VA 23651 ATTN: DRCPM-MI13 WARREN MI 48090 CDR US ARMY TRANSPORTATION SCHOOL PROJ MGR, MOBILE ELECTRIC POWER ATTN: ATS P-CD...for the Deutz F3L 912W and the Perkins 4.203.2 49 6 / t . . ...... ....low I. INTRODUCTION The U.S. Army currently uses electric forklifts in handling...hazardous materials. Although these electric forklifts have certain inherent desirable characteristics, i.e., no pollution or noise, the logistics
NASA Astrophysics Data System (ADS)
Lee, T. S.; Robb, J. D.
The ring discharge hazard to a carbon-reinforced-composites fuel tank skin under lightning strike conditions is investigated. A model of anisotropy in electric conductivity is adopted whereby longitudinal conductivity and transverse conductivity are considered separately. It is concluded that the current flow pattern contains a stagnation-dominated near-field region and a geometry-dominated far-field decaying region. While this pattern is unaltered by anisotropy in conductivity, the accompanying nonliner electrical field pattern is greatly distorted. It is noted that conclusions applicable to the ignition hazard which were derived from the model of a uniform scalar conductivity for the skin still remain intact.
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-25
... Standards of Performance for Fossil-Fuel-Fired Electric Utility, Industrial- Commercial-Institutional, and... Utility Steam Generating Units and Standards of Performance for Fossil-Fuel-Fired Electric Utility.... Electronic files should avoid the use of special characters, any form of encryption, and be free of any...
Code of Federal Regulations, 2010 CFR
2010-10-01
... transported under deck, provided the following requirements are met: (1) The cargo space shall be provided... in accordance with the requirements under which they were manufactured. (7) Electrical circuits in the cargo spaces must meet the hazardous area requirements in subchapter J (Electrical Engineering...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
78 FR 23308 - Petitions for Modification of Application of Existing Mandatory Safety Standards
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-18
... electrical condition of the slope conveyor system. (c) Immediate reporting of any hazards or mechanical... Affected: 30 CFR 75.1710-1(a)(4) (Canopies or cabs; self-propelled diesel-powered and electric face... existing standard to permit the use of shuttle cars without canopies in heights less than forty eight...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
46 CFR 111.105-43 - Paint stowage or mixing spaces.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Paint stowage or mixing spaces. 111.105-43 Section 111... ELECTRIC SYSTEMS-GENERAL REQUIREMENTS Hazardous Locations § 111.105-43 Paint stowage or mixing spaces. A space for the stowage or mixing of paint must not have any electric equipment, except: (a) Intrinsically...
30 CFR 56.4600 - Extinguishing equipment.
Code of Federal Regulations, 2011 CFR
2011-07-01
..., soldering, thawing, or bending— (1) With an electric arc or with an open flame where an electrically... extinguisher or other extinguisher with at least a 2-A:10-B:C rating shall be at the worksite. (2) With an open... equivalent fire extinguishing equipment for the class of fire hazard present shall be at the worksite. (b...
Comparative hazard evaluation of near-infrared diode lasers.
Marshall, W J
1994-05-01
Hazard evaluation methods from various laser protection standards differ when applied to extended-source, near-infrared lasers. By way of example, various hazard analyses are applied to laser training systems, which incorporate diode lasers, specifically those that assist in training military or law enforcement personnel in the proper use of weapons by simulating actual firing by the substitution of a beam of near-infrared energy for bullets. A correct hazard evaluation of these lasers is necessary since simulators are designed to be directed toward personnel during normal use. The differences among laser standards are most apparent when determining the hazard class of a laser. Hazard classification is based on a comparison of the potential exposures with the maximum permissible exposures in the 1986 and 1993 versions of the American National Standard for the Safe Use of Lasers, Z136.1, and the accessible emission limits of the federal laser product performance standard. Necessary safety design features of a particular system depend on the hazard class. The ANSI Z136.1-1993 standard provides a simpler and more accurate hazard assessment of low-power, near-infrared, diode laser systems than the 1986 ANSI standard. Although a specific system is evaluated, the techniques described can be readily applied to other near-infrared lasers or laser training systems.
Small-diameter timber alchemy: can utilization pay the way toward fire-resistant forests
Jeremy S. Fried; R. Jamie Barbour; Roger D. Fight; Glenn Christensen; Guy Pinjuv
2008-01-01
There is growing interest in using biomass removed from hazardous fuels reduction treatments in wood-fired electrical generation facilities. An application of FIA BioSum to southwest Oregonâs Klamath ecoregion assessed the financial feasibility of fuel treatment and biomass generation under a range of product prices and fire hazard-motivated silvicultural prescriptions...
Code of Federal Regulations, 2010 CFR
2010-07-01
... accumulate on electrical installations, wiring shall be in rigid conduit or in boxes containing no taps... pressure. (12) Wiring, motors and equipment in a spray booth shall be of approved explosion-proof type for..., Hazardous Locations. Wiring, motors and equipment within 20 feet (6.1m) of any interior spraying area and...
Fire Safety Power. Sixth Grade. Fire Safety for Texans: Fire and Burn Prevention Curriculum Guide.
ERIC Educational Resources Information Center
Texas State Commission on Fire Protection, Austin.
This booklet comprises the sixth grade component of a series of curriculum guides on fire and burn prevention. Designed to meet the age-specific needs of sixth grade students, its objectives include: (1) developing a comprehensive understanding of fire physics, (2) evaluating electrical hazards and how to respond to those hazards, and (3)…
Hennebert, Pierre
2018-04-01
Different ecotoxicological test batteries and concentration limits have been proposed to assess the hazard property (HP) HP 14 'Ecotoxic' for waste in the European Union and its member states. In test batteries, if the concentration of waste in the culture/dilution medium producing 50% of inhibitory biological effect in one or more test(s) is below the concentration limit of the test, the waste is classified as hazardous. A summarized review of the test batteries proposed since 1998 is presented. The last proposed test battery uses seven aquatic and terrestrial species with standardized methods, but with options and uniform concentration limits of 10% of waste eluate or solid waste in the culture/dilution medium. No attempt was made to match this hazard assessment with the classification made in the European List of Waste (LoW). The aim of this paper is to propose for the same test battery (reduced to 6 tests without options) concentration limits that match with the European List of Waste. This list was taken as reference (despite the fact that waste can be hazardous for other properties than the most frequent HP 14, and its partly political nature for some opinions). The concentration limits (CLs) for tests are the concentrations producing the highest ecotoxicological effects for each test observed in a non-hazardous waste set. Data from Germany, France and Belgium (from in total 5 different sources from 2009 to 2016) with the above-mentioned test battery (without options) were gathered for 81 samples, being the largest set ever published. In total, ten non-hazardous (NH) waste samples (as defined by the LoW and for most of them checked by chemical composition) were used to establish CLs. These CLs were then applied to 13 hazardous (H) waste by the LoW, and all were classified as hazardous. The matching of the resulting classification with the LoW is convincing. For the 58 'mirror entries' in the LoW (hazardous or not depending of the presence of hazardous substances), 37 were classified H (64%) and 21 were classified NH (36%). These concentration limits can be refined with the method proposed here, as soon as additional data of NH waste (by list and by composition) are available. The test battery (without options) and the concentration limits (in percent of waste in the culture/dilution medium) proposed are the following: A waste is hazardous for HP 14 'Ecotoxic' if the concentration of waste (eluate or solid) in the culture/dilution medium producing 50% of biological effect relative to the control EC 50 -30 min of Vibrio fischeri (EN ISO 11348-3) is lower than 15.8%, or if the EC 50 -72 h of Pseudokirchneriella subcapitata (EN ISO 8692) is lower than 7.03%, or if the EC 50 -48 h of Daphnia magna (EN ISO 6341) is lower than 7.95%, or if the EC 50 -6h of Arthrobacter globiformis (ISO 18187) is lower than 2.25%, or if the EC 50 -14d of Brassica rapa (EN ISO 11269-2) is lower than 13.7%, or if the EC 50 -48 h of Eisenia fetida avoidance test (ISO 17512-1) is lower than 3.75%. These CLs range between 2% and 16%, which is in line with the typically 10% concentration proposed without validation. To fix regulatory concentration limits, the regulators can use these CLs and the uncertainty of the ecotoxicological tests (standard deviation of inter-laboratory reproducibility typically of 25% of the mean, as published in the standards). Classification of waste for HP 14 with these tests and concentration limits will agree with the European List of Waste. Copyright © 2017 Elsevier Ltd. All rights reserved.
1986-01-01
7 O-AI6 175 TWO- 1NENSION L SIGNAL PROCESSING AD STORAGE AND IA-1 ATLANTA SCHOOL OF ELECTRICAL ENGINEERING.. ULRSSIFIED R SCHAFER ET AL. SI JAN... ELECTRICAL ENGINEERING L’- ATLANTA, GEORGIA 30332 .’ -.. .. ~ i 4 2 i 2 " , I IT= J ., . 4 2.~ i1 ov--.,-w. A -A *- t . . . SECURITY CLASSIFICATION O0...School of Electrical Engineering Atlanta, Georgia 30332 Research Triangle Park, NC 27709 •e. NAME OP PUNOINGMSONSORING 0b. OPPIC SYMBOL L PROCUREMENT
Federal Register 2010, 2011, 2012, 2013, 2014
2011-11-15
... Classification System. \\2\\ Maximum Achievable Control Technology. Table 2 is not intended to be exhaustive, but..., methods, systems, or techniques that reduce the volume of or eliminate HAP emissions through process changes, substitution of materials, or other modifications; enclose systems or processes to eliminate...
Many units in public housing or other low-income urban dwellings may have elevated pesticide residues, given recurring infestation, but it would be logistically and economically infeasible to sample a large number of units to identify highly exposed households to design interven...
Categorizing Drugs and Drug-Taking: A More Meaningful Approach.
ERIC Educational Resources Information Center
Gold, Robert S.; Duncan, David F.
This document reviews various definitions of the nature and classification of drugs. Difficulties with existing categorizations which use such bases as clinical utility, molecular structure, effects on the central nervous system, legality, and hazard potential are disucssed. A more meaningful categorization based on the availability and sources of…
Code of Federal Regulations, 2011 CFR
2011-10-01
... Federal Acquisition Regulations System AGENCY FOR INTERNATIONAL DEVELOPMENT GENERAL CONTRACTING... Secretary of Labor may waive the applicability of the Defense Base Act (DBA) with respect to any contract, subcontract, or subordinate contract, work location, or classification of employees. Either the contractor or...
Energy dissipation on flat-sloped stepped spillways: Part 2. Downstream of the inception point
USDA-ARS?s Scientific Manuscript database
Many small earthen embankments are faced with inadequate spillway capacity due to filled sediment pools filled with sediment and sediment now filling flood pools. Additionally, hydrologic conditions have changed as a result of urbanization; thereby causing changes in the hazard classification of th...
Chronic fish toxicity is a key parameter for hazard classification and environmental risk assessment of chemicals, and the OECD 210 fish early life-stage (FELS) test is the primary guideline test used for various international regulatory programs. There exists a need to develop ...
Overview of hybrid electric vehicle trend
NASA Astrophysics Data System (ADS)
Wang, Haomiao; Yang, Weidong; Chen, Yingshu; Wang, Yun
2018-04-01
With the increase of per capita energy consumption, environmental pollution is worsening. Using new alternative sources of energy, reducing the use of conventional fuel-powered engines is imperative. Due to the short period, pure electric vehicles cannot be mass-produced and there are many problems such as imperfect charging facilities. Therefore, the development of hybrid electric vehicles is particularly important in a certain period. In this paper, the classification of hybrid vehicle, research status of hybrid vehicle and future development trends of hybrid vehicles is introduced. It is conducive to the public understanding of hybrid electric vehicles, which has a certain theoretical significance.
Participatory Classification in a System for Assessing Multimodal Transportation Patterns
2015-02-17
Culler Electrical Engineering and Computer Sciences University of California at Berkeley Technical Report No. UCB/EECS-2015-8 http...California at Berkeley,Electrical Engineering and Computer Sciences,Berkeley,CA,94720 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING...confirmation screen This section sketches the characteristics of the data that was collected, computes the accuracy of the auto- mated inference algorithm
Physical hazard safety awareness among healthcare workers in Tanta university hospitals, Egypt.
El-Sallamy, Rania M; Kabbash, Ibrahim Ali; El-Fatah, Sanaa Abd; El-Feky, Asmaa
2017-05-17
Hospital workers are exposed to many occupational hazards that may threaten their health and safety. Physical hazards encountered in hospital working environment include temperature, illumination, noise, electrical injuries, and radiation. To assess the awareness of healthcare workers (HCWs) about physical hazards in Tanta university hospitals, this cross-sectional study included 401 HCWs (physicians, nurses, technicians, and workers) from seven departments (general surgery, orthopedics, radiology, ophthalmology, kitchen, incinerator, and laundry). Data were collected through interview questionnaire to assess six types of physical hazards (noise, electric hazards, temperature, radiation, fire, and lighting,). Most of the physicians (63.7%) were aware of the level of noise. All physicians, nurses, technicians, and majority of workers reported that hearing protective devices were not available, and all HCWs reported that periodic hearing examination was not performed. Most of the nurses (75.2%) and workers (68.5%) did not attended emergency training, and more than two thirds of all HCWs were not briefed about emergency evacuation. Most HCWs were not given appropriate radiation safety training before starting work (88% of workers, 73.7% of nurses, 65.7% of physicians, and 68.3% of technicians). The majority of physicians, nurses, and technicians (70.5, 65.4, and 53.7%) denied regular environmental monitoring for radiation level inside work place. Health education programs on health and safety issues regarding physical hazards should be mandatory to all healthcare workers to improve their awareness and protect them from undue exposures they may face due to lack of adequate awareness and knowledge. There is urgent need of expanding the occupational healthcare services in Egypt to cover all the employees as indicated by the international recommendations and the Egyptian Constitution, legislation, and community necessity.
NASA Astrophysics Data System (ADS)
Linek, M.; Jungmann, M.; Berlage, T.; Clauser, C.
2005-12-01
Within the Ocean Drilling Program (ODP), image logging tools have been routinely deployed such as the Formation MicroScanner (FMS) or the Resistivity-At-Bit (RAB) tools. Both logging methods are based on resistivity measurements at the borehole wall and therefore are sensitive to conductivity contrasts, which are mapped in color scale images. These images are commonly used to study the structure of the sedimentary rocks and the oceanic crust (petrologic fabric, fractures, veins, etc.). So far, mapping of lithology from electrical images is purely based on visual inspection and subjective interpretation. We apply digital image analysis on electrical borehole wall images in order to develop a method, which augments objective rock identification. We focus on supervised textural pattern recognition which studies the spatial gray level distribution with respect to certain rock types. FMS image intervals of rock classes known from core data are taken in order to train textural characteristics for each class. A so-called gray level co-occurrence matrix is computed by counting the occurrence of a pair of gray levels that are a certain distant apart. Once the matrix for an image interval is computed, we calculate the image contrast, homogeneity, energy, and entropy. We assign characteristic textural features to different rock types by reducing the image information into a small set of descriptive features. Once a discriminating set of texture features for each rock type is found, we are able to discriminate the entire FMS images regarding the trained rock type classification. A rock classification based on texture features enables quantitative lithology mapping and is characterized by a high repeatability, in contrast to a purely visual subjective image interpretation. We show examples for the rock classification between breccias, pillows, massive units, and horizontally bedded tuffs based on ODP image data.
Rock classification based on resistivity patterns in electrical borehole wall images
NASA Astrophysics Data System (ADS)
Linek, Margarete; Jungmann, Matthias; Berlage, Thomas; Pechnig, Renate; Clauser, Christoph
2007-06-01
Electrical borehole wall images represent grey-level-coded micro-resistivity measurements at the borehole wall. Different scientific methods have been implemented to transform image data into quantitative log curves. We introduce a pattern recognition technique applying texture analysis, which uses second-order statistics based on studying the occurrence of pixel pairs. We calculate so-called Haralick texture features such as contrast, energy, entropy and homogeneity. The supervised classification method is used for assigning characteristic texture features to different rock classes and assessing the discriminative power of these image features. We use classifiers obtained from training intervals to characterize the entire image data set recovered in ODP hole 1203A. This yields a synthetic lithology profile based on computed texture data. We show that Haralick features accurately classify 89.9% of the training intervals. We obtained misclassification for vesicular basaltic rocks. Hence, further image analysis tools are used to improve the classification reliability. We decompose the 2D image signal by the application of wavelet transformation in order to enhance image objects horizontally, diagonally and vertically. The resulting filtered images are used for further texture analysis. This combined classification based on Haralick features and wavelet transformation improved our classification up to a level of 98%. The application of wavelet transformation increases the consistency between standard logging profiles and texture-derived lithology. Texture analysis of borehole wall images offers the potential to facilitate objective analysis of multiple boreholes with the same lithology.
20th JANNAF Propulsion Systems Hazards Subcommittee Meeting. Volume 1
NASA Technical Reports Server (NTRS)
Cocchiaro, James E. (Editor); Eggleston, Debra S. (Editor); Gannaway, Mary T. (Editor); Inzar, Jeanette M. (Editor)
2002-01-01
This volume, the first of two volumes, is a collection of 24 unclassified/unlimited-distribution papers which were presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 20th Propulsion Systems Hazards Subcommittee (PSHS), 38th Combustion Subcommittee (CS), 26th Airbreathing Propulsion Subcommittee (APS), and 21 Modeling and Simulation Subcommittee meeting. The meeting was held 8-12 April 2002 at the Bayside Inn at The Sandestin Golf & Beach Resort and Eglin Air Force Base, Destin, Florida. Topics covered include: insensitive munitions and hazard classification testing of solid rocket motors and other munitions; vulnerability of gun propellants to impact stimuli; thermal decomposition and cookoff properties of energetic materials; burn-to-violent reaction phenomena in energetic materials; and shock-to-detonation properties of solid propellants and energetic materials.
JANNAF 19th Propulsion Systems Hazards Subcommittee Meeting. Volume 1
NASA Technical Reports Server (NTRS)
Cocchiaro, James E. (Editor); Kuckels, Melanie C. (Editor)
2000-01-01
This volume, the first of two volumes is a compilation of 25 unclassified/unlimited-distribution technical papers presented at the Joint Army-Navy-NASA-Air Force (JANNAF) 19th Propulsion Systems Hazards Subcommittee (PSHS) meeting held jointly with the 37th Combustion Subcommittee (CS) and 25th Airbreathing Propulsion Subcommittee (APS), and 1st Modeling and Simulation Subcommittee (MSS) meetings. The meeting was held 13-17 November 2000 at the Naval Postgraduate School and Hyatt Regency Hotel, Monterey, California. Topics covered at the PSHS meeting include: impact and thermal vulnerability of gun propellants; thermal decomposition and cookoff behavior of energetic materials; violent reaction and detonation phenomena of solid energetic materials subjected to shock and impact loading; and hazard classification, and insensitive munitions testing of propellants and propulsion systems.
Stull, Jeffrey O
2004-01-01
The paper describes the development of a comprehensive decision logic for selection and use of biological and chemical protective clothing (BCPC). The decision logic recognizes the separate areas of BCPC use among emergency, biological, and chemical hazards. The proposed decision logic provides a system for type classifying BCPC in terms of its compliance with existing standards (for emergency applications), the overall clothing integrity, and the material barrier performance. Type classification is offered for garments, gloves, footwear, and eye/face protection devices. On the basis of multiple, but simply designed flowcharts, the type of BCPC appropriate for specific biological and chemical hazards can be selected. The decision logic also provides supplemental considerations for choosing appropriate BCPC features.
1984-12-01
AFLRL No. 178 By oi Harry E. Dietzmann ,< Engines, Emissions.and Vehicle Research Division Southwest Research Institute San Antonio, Texas Prppared...the possibility of replacing the currently used electric forklift with diesel engine-powered forklifts in handling hazardous materials. Electric ...concern; however, these concerns may be amplified when the vehicle is operating under a malfunction mode. Malfunctions include simulating a plugged
Solar Water Heater Installation Package
NASA Technical Reports Server (NTRS)
1982-01-01
A 48-page report describes water-heating system, installation (covering collector orientation, mounting, plumbing and wiring), operating instructions and maintenance procedures. Commercial solar-powered water heater system consists of a solar collector, solar-heated-water tank, electrically heated water tank and controls. Analysis of possible hazards from pressure, electricity, toxicity, flammability, gas, hot water and steam are also included.
Risk-Aware Planetary Rover Operation: Autonomous Terrain Classification and Path Planning
NASA Technical Reports Server (NTRS)
Ono, Masahiro; Fuchs, Thoams J.; Steffy, Amanda; Maimone, Mark; Yen, Jeng
2015-01-01
Identifying and avoiding terrain hazards (e.g., soft soil and pointy embedded rocks) are crucial for the safety of planetary rovers. This paper presents a newly developed groundbased Mars rover operation tool that mitigates risks from terrain by automatically identifying hazards on the terrain, evaluating their risks, and suggesting operators safe paths options that avoids potential risks while achieving specified goals. The tool will bring benefits to rover operations by reducing operation cost, by reducing cognitive load of rover operators, by preventing human errors, and most importantly, by significantly reducing the risk of the loss of rovers.
Oral bioaccessibility testing and read-across hazard assessment of nickel compounds.
Henderson, Rayetta G; Cappellini, Danielle; Seilkop, Steven K; Bates, Hudson K; Oller, Adriana R
2012-06-01
In vitro metal ion bioaccessibility, as a measure of bioavailability, can be used to read-across toxicity information from data-rich, source substances to data-poor, target substances. To meet the data requirements for oral systemic toxicity endpoints under the REACH Regulation in Europe, 12 nickel substances underwent bioaccessibility testing in stomach and intestinal fluids. A read-across paradigm was developed based on the correlation between gastric bioaccessibility and in vivo acute oral toxicity. The oral LD₅₀ values were well predicted by nickel release (R² = 0.91). Samples releasing <48% available nickel (mgNi released/mg available Ni × 100) are predicted to have an LD₅₀ > 2000 mg/kg; while samples releasing > 76% available nickel are expected to have an LD₅₀ between 300 and 2000 mg/kg. The hazard classifications (European Regulation on Classification, Labelling and Packaging of Chemical Substances and Mixtures) for all oral systemic endpoints were evaluated based on read-across from three source nickel compounds (sulfate, subsulfide, oxide). Samples releasing < 48% available nickel were read-across from nickel oxides and subsulfide. Samples releasing > 76% Ni were read-across from nickel sulfate. This assessment suggests that nickel chloride and dihydroxide should be less stringently classified and nickel sulfamate should receive a more stringent classification for oral systemic endpoints than currently assigned. Copyright © 2012 Elsevier Inc. All rights reserved.
Hazard calculations of diffuse reflected laser radiation for the SELENE program
NASA Technical Reports Server (NTRS)
Miner, Gilda A.; Babb, Phillip D.
1993-01-01
The hazards from diffuse laser light reflections off water clouds, ice clouds, and fog and from possible specular reflections off ice clouds were assessed with the American National Standards (ANSI Z136.1-1986) for the free-electron-laser parameters under consideration for the Segmented Efficient Laser Emission for Non-Nuclear Electricity (SELENE) Program. Diffuse laser reflection hazards exist for water cloud surfaces less than 722 m in altitude and ice cloud surfaces less than 850 m in altitude. Specular reflections from ice crystals in cirrus clouds are not probable; however, any specular reflection is a hazard to ground observers. The hazard to the laser operators and any ground observers during heavy fog conditions is of such significant magnitude that the laser should not be operated in fog.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bridges, J.E.; Frazier, M.J.
1979-09-01
The effects of 60-Hz electric and magnetic fields of exta-high voltage (EHV) transmission lines on the performance of implanted cardiac pacemakers were studied by: (1) in vitro bench tests of a total of thirteen cardiac pacemakers; (2) in vivo tests of six implanted cardiac pacemakers in baboons; and (3) non-hazardous skin measurement tests on four humans. Analytical methods were developed to predict the thresholds of body current and electric fields capable of affecting normal pacemaker operation in humans. The field strengths calculated to alter implanted pacemaker performance were compared with the range of maximum electric and magnetic field strengths amore » human would normally encounter under transmission lines of various voltages. Results indicate that the electric field or body current necessary to alter the normal operation of pacemakers is highly dependent on the type of pacemaker and the location of the implanted electrodes. However, cardiologists have not so far detected harmful effects of pacemaker reversion to the asynchronous mode in current types of pacemakers and with present methods of implantation. Such interferences can be eliminated by using advanced pacemakers less sensitive to 60-Hz voltages or by using implantation lead arrangements less sensitive to body current.« less
ThinkHazard!: an open-source, global tool for understanding hazard information
NASA Astrophysics Data System (ADS)
Fraser, Stuart; Jongman, Brenden; Simpson, Alanna; Nunez, Ariel; Deparday, Vivien; Saito, Keiko; Murnane, Richard; Balog, Simone
2016-04-01
Rapid and simple access to added-value natural hazard and disaster risk information is a key issue for various stakeholders of the development and disaster risk management (DRM) domains. Accessing available data often requires specialist knowledge of heterogeneous data, which are often highly technical and can be difficult for non-specialists in DRM to find and exploit. Thus, availability, accessibility and processing of these information sources are crucial issues, and an important reason why many development projects suffer significant impacts from natural hazards. The World Bank's Global Facility for Disaster Reduction and Recovery (GFDRR) is currently developing a new open-source tool to address this knowledge gap: ThinkHazard! The main aim of the ThinkHazard! project is to develop an analytical tool dedicated to facilitating improvements in knowledge and understanding of natural hazards among non-specialists in DRM. It also aims at providing users with relevant guidance and information on handling the threats posed by the natural hazards present in a chosen location. Furthermore, all aspects of this tool will be open and transparent, in order to give users enough information to understand its operational principles. In this presentation, we will explain the technical approach behind the tool, which translates state-of-the-art probabilistic natural hazard data into understandable hazard classifications and practical recommendations. We will also demonstrate the functionality of the tool, and discuss limitations from a scientific as well as an operational perspective.
Usage monitoring of electrical devices in a smart home.
Rahimi, Saba; Chan, Adrian D C; Goubran, Rafik A
2011-01-01
Profiling the usage of electrical devices within a smart home can be used as a method for determining an occupant's activities of daily living. A nonintrusive load monitoring system monitors the electrical consumption at a single electrical source (e.g., main electric utility service entry) and the operating schedules of individual devices are determined by disaggregating the composite electrical consumption waveforms. An electrical device's load signature plays a key role in nonintrusive load monitoring systems. A load signature is the unique electrical behaviour of an individual device when it is in operation. This paper proposes a feature-based model, using the real power and reactive power as features for describing the load signatures of individual devices. Experimental results for single device recognition for 7 devices show that the proposed approach can achieve 100% classification accuracy with discriminant analysis using Mahalanobis distances.
A re-evaluation of PETROTOX for predicting acute and chronic toxicity of petroleum substances.
Redman, Aaron D; Parkerton, Thomas F; Leon Paumen, Miriam; Butler, Josh D; Letinski, Daniel J; den Haan, Klass
2017-08-01
The PETROTOX model was developed to perform aquatic hazard assessment of petroleum substances based on substance composition. The model relies on the hydrocarbon block method, which is widely used for conducting petroleum substance risk assessments providing further justification for evaluating model performance. Previous work described this model and provided a preliminary calibration and validation using acute toxicity data for limited petroleum substance. The objective of the present study was to re-evaluate PETROTOX using expanded data covering both acute and chronic toxicity endpoints on invertebrates, algae, and fish for a wider range of petroleum substances. The results indicated that recalibration of 2 model parameters was required, namely, the algal critical target lipid body burden and the log octanol-water partition coefficient (K OW ) limit, used to account for reduced bioavailability of hydrophobic constituents. Acute predictions from the updated model were compared with observed toxicity data and found to generally be within a factor of 3 for algae and invertebrates but overestimated fish toxicity. Chronic predictions were generally within a factor of 5 of empirical data. Furthermore, PETROTOX predicted acute and chronic hazard classifications that were consistent or conservative in 93 and 84% of comparisons, respectively. The PETROTOX model is considered suitable for the purpose of characterizing petroleum substance hazard in substance classification and risk assessments. Environ Toxicol Chem 2017;36:2245-2252. © 2017 SETAC. © 2017 SETAC.
Apparatus for the plasma destruction of hazardous gases
Kang, M.
1995-02-07
A plasma cell for destroying hazardous gases is described. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required. 4 figs.
Apparatus for the plasma destruction of hazardous gases
Kang, Michael
1995-01-01
A plasma cell for destroying hazardous gases. An electric-discharge cell having an electrically conducting electrode onto which an alternating high-voltage waveform is impressed and a dielectric barrier adjacent thereto, together forming a high-voltage electrode, generates self-terminating discharges throughout a volume formed between this electrode and a grounded conducting liquid electrode. The gas to be transformed is passed through this volume. The liquid may be flowed, generating thereby a renewable surface. Moreover, since hydrochloric and hydrofluoric acids may be formed from destruction of various chlorofluorocarbons in the presence of water, a conducting liquid may be selected which will neutralize these corrosive compounds. The gases exiting the discharge region may be further scrubbed if additional purification is required.
Risk assessment for safety laboratories in Politeknik Negeri Medan
NASA Astrophysics Data System (ADS)
Viyata Sundawa, Bakti; Hutajulu, Elferida; Sirait, Regina; Banurea, Waldemar; Indrayadi; Mulyadi, Sangap
2017-09-01
International Labour Organization (ILO) estimated 2.34 million people die each year because accidents and diseases in workplace. It also impact to economic losses in some countries. It need to do safety and healthy in working environment especially in laboratory. Identification of potential hazards and risks must be done in Telecommunication Laboratory Politeknik Negeri Medan. Therefore, this study was assessed 5 of potential hazards and risks in our laboratory by Likert Scale. This object was divided into 2 assessment namely likelihood of hazards and severity of consequences. Collecting data is taken from questionnaire who involved 100 students at random academic level. The result showed The highest score is chemical hazards 73.2% in likelihood of hazards and electrical hazards 85% in severity of consequences. This condition is classified as “high” state. Big attention must be given to “high” state because it can help us to determine mitigate action.
Cocron, Peter; Bachl, Veronika; Früh, Laura; Koch, Iris; Krems, Josef F
2014-12-01
The low noise emission of battery electric vehicles (BEVs) has led to discussions about how to address potential safety issues for other road users. Legislative actions have already been undertaken to implement artificial sounds. In previous research, BEV drivers reported that due to low noise emission they paid particular attention to pedestrians and bicyclists. For the current research, we developed a hazard detection task to test whether drivers with BEV experience respond faster to incidents, which arise due to the low noise emission, than inexperienced drivers. The first study (N=65) revealed that BEV experience only played a minor role in drivers' response to hazards resulting from low BEV noise. The tendency to respond, reaction times and hazard evaluations were similar among experienced and inexperienced BEV drivers; only small trends in the assumed direction were observed. Still, both groups clearly differentiated between critical and non-critical scenarios and responded accordingly. In the second study (N=58), we investigated additionally if sensitization to low noise emission of BEVs had an effect on hazard perception in incidents where the noise difference is crucial. Again, participants in all groups differentiated between critical and non-critical scenarios. Even though trends in response rates and latencies occurred, experience and sensitization to low noise seemed to only play a minor role in detecting hazards due to low BEV noise. An additional global evaluation of BEV noise further suggests that even after a short test drive, the lack of noise is perceived more as a comfort feature than a safety threat. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chow, Dorothy K L; Leong, Rupert W L; Lai, Larry H; Wong, Grace L H; Leung, Wai-Keung; Chan, Francis K L; Sung, Joseph J Y
2008-04-01
Phenotypic evolution of Crohn's disease occurs in whites but has never been described in other populations. The Montreal classification may describe phenotypes more precisely. The aim of this study was to validate the Montreal classification through a longitudinal sensitivity analysis in detecting phenotypic variation compared to the Vienna classification. This was a retrospective longitudinal study of consecutive Chinese Crohn's disease patients. All cases were classified by the Montreal classification and the Vienna classification for behavior and location. The evolution of these characteristics and the need for surgery were evaluated. A total of 109 patients were recruited (median follow-up: 4 years, range: 6 months-18 years). Crohn's disease behavior changed 3 years after diagnosis (P = 0.025), with an increase in stricturing and penetrating phenotypes, as determined by the Montreal classification, but was only detected by the Vienna classification after 5 years (P = 0.015). Disease location remained stable on follow-up in both classifications. Thirty-four patients (31%) underwent major surgery during the follow-up period with the stricturing [P = 0.002; hazard ratio (HR): 3.3; 95% CI: 1.5-7.0] and penetrating (P = 0.03; HR: 5.8; 95% CI: 1.2-28.2) phenotypes according to the Montreal classification associated with the need for major surgery. In contrast, colonic disease was protective against a major operation (P = 0.02; HR: 0.3; 95% CI: 0.08-0.8). This is the first study demonstrating phenotypic evolution of Crohn's disease in a nonwhite population. The Montreal classification is more sensitive to behavior phenotypic changes than is the Vienna classification after excluding perianal disease from the penetrating disease category and was useful in predicting course and the need for surgery.
Electrical burn injuries of workers using portable aluminium ladders near overhead power lines.
Moghtader, J C; Himel, H N; Demun, E M; Bellian, K T; Edlich, R F
1993-10-01
The use of aluminium ladders around high voltage power lines has resulted in a significant number of electrical injuries and electrocutions. Workers often misjudge wire distances or lose control of fully extended ladders, thereby exposing themselves to electrocution hazard. High-voltage electrical burns of two workers using an aluminium ladder that contacted a high voltage power line are reported. The circumstances surrounding the injury, the clinical management of the case, and the methods of prevention are presented and discussed.
Fadeyibi, I.O.; Izegbu, M.C.; Benebo, A.S.; Ademuluyi, S.A.
2007-01-01
Summary The case reported is that of a communications technician admitted to hospital with 38% burns sustained while climbing a communications mast. The mast was erected less than 3 metres from a 33 kv electric transmission cable. His condition is described, as also the treatment he received until his discharge three months later. In the absence of guidelines regarding the erection of such masts, a number of recommendations are made. PMID:21991082
EMP/GMD Phase 0 Report, A Review of EMP Hazard Environments and Impacts
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rivera, Michael Kelly; Backhaus, Scott N.; Woodroffe, Jesse Richard
The purpose of this study is to determine methods to analyze the hazard environments, impacts, and consequences of different sources of electromagnetic pulse (EMP), including nuclear electromagnetic pulse (NEMP) and geomagnetic disturbance (GMD) on the U.S. electric power infrastructures and to use those methods to determine EMP and GMD events of concern. The study will be carried out in four phases, each of which will provide higher levels of analytic fidelity that focuses on those EMP/GMD sources and events that create significant consequences, or whose consequences are sufficiently uncertain, to require more in-depth study. This study will leverage the bestmore » experimental data; device, equipment and system models; and simulation tools currently available. This study focuses primarily on the bulk electric system (BES) including large generating stations, large power transformers, the transmission network, and transmission system protection. Electrical distribution systems may potentially be included, if warranted, after consideration of the consequences for the bulk power system.« less
NASA Astrophysics Data System (ADS)
Ohsawa, A.
2011-06-01
This paper presents a statistical analysis of 153 accidents attributable to static electricity in Japanese industry over the last 50 years. A more thorough understanding of their causes could help prevent similar incidents and identify hazards that could assist in the task of risk assessment. Most of the incidents occurred during operations performed by workers. In addition, more than 70% of the flammable atmospheres resulted from the presence of vapours. A noteworthy finding is that at least 70% of the ignitions were caused by isolated conductors including operators' bodies leading to spark discharges, which could have easily been prevented with earthing. These tendencies indicate that, when operators handle flammable liquids with any conductors, the ignition risk is significantly high. A serious lack of information regarding fundamental countermeasures for static electricity seems to be the main cause of such hazards. Only organised management, including education and risk communication, would prevent them.
The DTIC Review. Volume 5, Number 3. Cybernetics: Enhancing Human Performance
2001-03-01
Human Factors Engineering 16. SECURITY CLASSIFICATION OF: 17. LIMITATION 18. NUMBER 19a. NAME OF RESPONSIBLE PERSON OF ABSTRACT OF PAGES Phyllis...2 AD Number: A382305 Corporate Author: Arizona University - Tucson Department of Electrical and Computer Engineering Tucson, AZ...Visualization Aids AD-A382305 Aug 2000 Arizona University - Tucson Department of Electrical and Computer Engineering Tucson, AZ 2 THIS PAGE INTENTIONALLY
Characterization and Physics-Based Modeling of Electrochemical Memristors
2015-11-16
conducting films that result from electrical or optical stress. Model parameters and electrical characteristics were obtained from and validated...x- ray scattering, Conductive Bridge Random Access Memory 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT 18. NUMBER OF PAGES 19a. NAME...Calculated DOS for GeSe2 in valence band and (b) conduction band .................. 43 Figure 45. DFT band structure for crystalline GeSe2
33 CFR 401.80 - Reporting dangerous cargo.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 33 Navigation and Navigable Waters 3 2010-07-01 2010-07-01 false Reporting dangerous cargo. 401.80... dangerous cargo. (a) The master of any explosive vessel or hazardous cargo vessel shall report to a Seaway station, as set out in Schedule III, the nature, quantity, and IMO classification of the dangerous cargo...
33 CFR 401.80 - Reporting dangerous cargo.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 33 Navigation and Navigable Waters 3 2011-07-01 2011-07-01 false Reporting dangerous cargo. 401.80... dangerous cargo. (a) The master of any explosive vessel or hazardous cargo vessel shall report to a Seaway station, as set out in Schedule III, the nature, quantity, and IMO classification of the dangerous cargo...
33 CFR 401.80 - Reporting dangerous cargo.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 33 Navigation and Navigable Waters 3 2012-07-01 2012-07-01 false Reporting dangerous cargo. 401.80... dangerous cargo. (a) The master of any explosive vessel or hazardous cargo vessel shall report to a Seaway station, as set out in Schedule III, the nature, quantity, and IMO classification of the dangerous cargo...
33 CFR 401.80 - Reporting dangerous cargo.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 33 Navigation and Navigable Waters 3 2014-07-01 2014-07-01 false Reporting dangerous cargo. 401.80... dangerous cargo. (a) The master of any explosive vessel or hazardous cargo vessel shall report to a Seaway station, as set out in Schedule III, the nature, quantity, and IMO classification of the dangerous cargo...
33 CFR 401.80 - Reporting dangerous cargo.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 33 Navigation and Navigable Waters 3 2013-07-01 2013-07-01 false Reporting dangerous cargo. 401.80... dangerous cargo. (a) The master of any explosive vessel or hazardous cargo vessel shall report to a Seaway station, as set out in Schedule III, the nature, quantity, and IMO classification of the dangerous cargo...
7 CFR Appendix A to Subpart E of... - Hazard Potential Classification for Civil Works Projects
Code of Federal Regulations, 2010 CFR
2010-01-01
... essential facilities and access Disruption of critical facilities and access. Property Losses 4 Private..., communications, power supply, etc. 4 Direct economic impact of value of property damages to project facilities and down stream property and indirect economic impact due to loss of project services, i.e., impact on...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-06-17
... example, ammonium nitrate fertilizer and ferrosilicon. The term PDM is functionally equivalent to term... the same as for ammonium nitrate fertilizer, UN 2067. c. Four comments opposed the classification of... limitations for ammonium nitrate fertilizer should be ensured by monitoring and controlling temperature at the...
46 CFR 153.12 - IMO Certificates for United States Ships.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false IMO Certificates for United States Ships. 153.12 Section... CARGOES SHIPS CARRYING BULK LIQUID, LIQUEFIED GAS, OR COMPRESSED GAS HAZARDOUS MATERIALS General § 153.12 IMO Certificates for United States Ships. Either a classification society authorized under 46 CFR part...
Space and Missile Systems Center Standard: Systems Engineering Requirements and Products
2013-07-01
unique hazard classification and explosive ordnance disposal requirements. (2) Operational and maintenance facilities and equipment requirements. (3...PAGE unclassified Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18 FOREWORD 1. This standard defines the Government’s requirements...49 4.3.14 Electromagnetic Interference and