Model documentation: Electricity Market Module, Electricity Fuel Dispatch Submodule
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
This report documents the objectives, analytical approach and development of the National Energy Modeling System Electricity Fuel Dispatch Submodule (EFD), a submodule of the Electricity Market Module (EMM). The report catalogues and describes the model assumptions, computational methodology, parameter estimation techniques, model source code, and forecast results generated through the synthesis and scenario development based on these components.
The Oak Ridge Competitive Electricity Dispatch (ORCED) Model Version 9
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hadley, Stanton W.; Baek, Young Sun
The Oak Ridge Competitive Electricity Dispatch (ORCED) model dispatches power plants in a region to meet the electricity demands for any single given year up to 2030. It uses publicly available sources of data describing electric power units such as the National Energy Modeling System and hourly demands from utility submittals to the Federal Energy Regulatory Commission that are projected to a future year. The model simulates a single region of the country for a given year, matching generation to demands and predefined net exports from the region, assuming no transmission constraints within the region. ORCED can calculate a numbermore » of key financial and operating parameters for generating units and regional market outputs including average and marginal prices, air emissions, and generation adequacy. By running the model with and without changes such as generation plants, fuel prices, emission costs, plug-in hybrid electric vehicles, distributed generation, or demand response, the marginal impact of these changes can be found.« less
NASA Astrophysics Data System (ADS)
Zainudin, Wan Nur Rahini Aznie; Becker, Ralf; Clements, Adam
2015-12-01
Many market participants in Australia Electricity Market had cast doubts on whether the pre-dispatch process in the electricity market is able to give them good and timely quantity and price information. In a study by [11], they observed a significant bias (mainly indicating that the pre-dispatch process tends to underestimate spot price outcomes), a seasonality features of the bias across seasons and/or trading periods and changes in bias across the years in our sample period (1999 to 2007). In a formal setting of an ordered probit model we establish that there are some exogenous variables that are able to explain increased probabilities of over- or under-predictions of the spot price. It transpires that meteorological data, expected pre-dispatch prices and information on past over- and under-predictions contribute significantly to explaining variation in the probabilities for over- and under-predictions. The results allow us to conjecture that some of the bids and re-bids provided by electricity generators are not made in good faith.
Load allocation of power plant using multi echelon economic dispatch
NASA Astrophysics Data System (ADS)
Wahyuda, Santosa, Budi; Rusdiansyah, Ahmad
2017-11-01
In this paper, the allocation of power plant load which is usually done with a single echelon as in the load flow calculation, is expanded into a multi echelon. A plant load allocation model based on the integration of economic dispatch and multi-echelon problem is proposed. The resulting model is called as Single Objective Multi Echelon Economic Dispatch (SOME ED). This model allows the distribution of electrical power in more detail in the transmission and distribution substations along the existing network. Considering the interconnection system where the distance between the plant and the load center is usually far away, therefore the loss in this model is seen as a function of distance. The advantages of this model is its capability of allocating electrical loads properly, as well as economic dispatch information with the flexibility of electric power system as a result of using multi-echelon. In this model, the flexibility can be viewed from two sides, namely the supply and demand sides, so that the security of the power system is maintained. The model was tested on a small artificial data. The results demonstrated a good performance. It is still very open to further develop the model considering the integration with renewable energy, multi-objective with environmental issues and applied to the case with a larger scale.
Parallel dispatch: a new paradigm of electrical power system dispatch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Jun Jason; Wang, Fei-Yue; Wang, Qiang
Modern power systems are evolving into sociotechnical systems with massive complexity, whose real-time operation and dispatch go beyond human capability. Thus, the need for developing and applying new intelligent power system dispatch tools are of great practical significance. In this paper, we introduce the overall business model of power system dispatch, the top level design approach of an intelligent dispatch system, and the parallel intelligent technology with its dispatch applications. We expect that a new dispatch paradigm, namely the parallel dispatch, can be established by incorporating various intelligent technologies, especially the parallel intelligent technology, to enable secure operation of complexmore » power grids, extend system operators U+02BC capabilities, suggest optimal dispatch strategies, and to provide decision-making recommendations according to power system operational goals.« less
Economic Dispatch for Microgrid Containing Electric Vehicles via Probabilistic Modeling: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yao, Yin; Gao, Wenzhong; Momoh, James
In this paper, an economic dispatch model with probabilistic modeling is developed for a microgrid. The electric power supply in a microgrid consists of conventional power plants and renewable energy power plants, such as wind and solar power plants. Because of the fluctuation in the output of solar and wind power plants, an empirical probabilistic model is developed to predict their hourly output. According to different characteristics of wind and solar power plants, the parameters for probabilistic distribution are further adjusted individually for both. On the other hand, with the growing trend in plug-in electric vehicles (PHEVs), an integrated microgridmore » system must also consider the impact of PHEVs. The charging loads from PHEVs as well as the discharging output via the vehicle-to-grid (V2G) method can greatly affect the economic dispatch for all of the micro energy sources in a microgrid. This paper presents an optimization method for economic dispatch in a microgrid considering conventional power plants, renewable power plants, and PHEVs. The simulation results reveal that PHEVs with V2G capability can be an indispensable supplement in a modern microgrid.« less
Hierarchical dispatch using two-stage optimisation for electricity markets in smart grid
NASA Astrophysics Data System (ADS)
Yang, Jie; Zhang, Guoshan; Ma, Kai
2016-11-01
This paper proposes a hierarchical dispatch method for the electricity markets consisting of wholesale markets and retail markets. In the wholesale markets, the generators and the retailers decide the generation and the purchase according to the market-clearing price. In the retail markets, the retailers set the retail price to adjust the electricity consumption of the consumers. Due to the two-way communications in smart grid, the retailers can decide the electricity purchase from the wholesale markets based on the information on electricity usage of consumers in the retail markets. We establish the hierarchical dispatch model for the wholesale markets and the retail markets and develop distributed algorithms to search for the optimal generation, purchase, and consumption. Numerical results show the balance between the supply and demand, the profits of the retailers, and the convergence of the distributed algorithms.
Optimal Dispatch of Unreliable Electric Grid-Connected Diesel Generator-Battery Power Systems
NASA Astrophysics Data System (ADS)
Xu, D.; Kang, L.
2015-06-01
Diesel generator (DG)-battery power systems are often adopted by telecom operators, especially in semi-urban and rural areas of developing countries. Unreliable electric grids (UEG), which have frequent and lengthy outages, are peculiar to these regions. DG-UEG-battery power system is an important kind of hybrid power system. System dispatch is one of the key factors to hybrid power system integration. In this paper, the system dispatch of a DG-UEG-lead acid battery power system is studied with the UEG of relatively ample electricity in Central African Republic (CAR) and UEG of poor electricity in Congo Republic (CR). The mathematical models of the power system and the UEG are studied for completing the system operation simulation program. The net present cost (NPC) of the power system is the main evaluation index. The state of charge (SOC) set points and battery bank charging current are the optimization variables. For the UEG in CAR, the optimal dispatch solution is SOC start and stop points 0.4 and 0.5 that belong to the Micro-Cycling strategy and charging current 0.1 C. For the UEG in CR, the optimal dispatch solution is of 0.1 and 0.8 that belongs to the Cycle-Charging strategy and 0.1 C. Charging current 0.1 C is suitable for both grid scenarios compared to 0.2 C. It makes the dispatch strategy design easier in commercial practices that there are a few very good candidate dispatch solutions with system NPC values close to that of the optimal solution for both UEG scenarios in CAR and CR.
Near-term implications of a ban on new coal-fired power plants in the United States.
Newcomer, Adam; Apt, Jay
2009-06-01
Large numbers of proposed new coal power generators in the United States have been canceled, and some states have prohibited new coal power generators. We examine the effects on the U.S. electric power system of banning the construction of coal-fired electricity generators, which has been proposed as a means to reduce U.S. CO2 emissions. The model simulates load growth, resource planning, and economic dispatch of the Midwest Independent Transmission System Operator (ISO), Inc., Electric Reliability Council of Texas (ERCOT), and PJM under a ban on new coal generation and uses an economic dispatch model to calculate the resulting changes in dispatch order, CO2 emissions, and fuel use under three near-term (until 2030) future electric power sector scenarios. A national ban on new coal-fired power plants does not lead to CO2 reductions of the scale required under proposed federal legislation such as Lieberman-Warner but would greatly increase the fraction of time when natural gas sets the price of electricity, even with aggressive wind and demand response policies.
Solar hybrid power plants: Solar energy contribution in reaching full dispatchability and firmness
NASA Astrophysics Data System (ADS)
Servert, Jorge F.; López, Diego; Cerrajero, Eduardo; Rocha, Alberto R.; Pereira, Daniel; Gonzalez, Lucía
2016-05-01
Renewable energies for electricity generation have always been considered as a risk for the electricity system due to its lack of dispatchability and firmness. Renewable energies penetration is constrained to strong grids or else its production must be limited to ensure grid stability, which is kept by the usage of hydropower energy or fossil-fueled power plants. CSP technology has an opportunity to arise not only as a dispatchable and firm technology, but also as an alternative that improves grid stability. To achieve that objective, solar hybrid configurations are being developed, being the most representative three different solutions: SAPG, ISCC and HYSOL. A reference scenario in Kingdom of Saudi Arabia (KSA) has been defined to compare these solutions, which have been modelled, simulated and evaluated in terms of dispatchability and firmness using ratios defined by the authors. The results show that: a) SAPG obtains the highest firmness KPI values, but no operation constraints have been considered for the coal boiler and the solar energy contribution is limited to 1.7%, b) ISCC provides dispatchable and firm electricity production but its solar energy contribution is limited to a 6.4%, and c) HYSOL presents the higher solar energy contribution of all the technologies considered: 66.0% while providing dispatchable and firm generation in similar conditions as SAPG and ISCC.
Flexible Energy Scheduling Tool for Integrating Variable Generation | Grid
, security-constrained economic dispatch, and automatic generation control programs. DOWNLOAD PAPER Electric commitment, security-constrained economic dispatch, and automatic generation control sub-models. Each sub resolutions and operating strategies can be explored. FESTIV produces not only economic metrics but also
A Hybrid Multilevel Storage Architecture for Electric Power Dispatching Big Data
NASA Astrophysics Data System (ADS)
Yan, Hu; Huang, Bibin; Hong, Bowen; Hu, Jing
2017-10-01
Electric power dispatching is the center of the whole power system. In the long run time, the power dispatching center has accumulated a large amount of data. These data are now stored in different power professional systems and form lots of information isolated islands. Integrating these data and do comprehensive analysis can greatly improve the intelligent level of power dispatching. In this paper, a hybrid multilevel storage architecture for electrical power dispatching big data is proposed. It introduces relational database and NoSQL database to establish a power grid panoramic data center, effectively meet power dispatching big data storage needs, including the unified storage of structured and unstructured data fast access of massive real-time data, data version management and so on. It can be solid foundation for follow-up depth analysis of power dispatching big data.
Dispatch Control with PEV Charging and Renewables for Multiplayer Game Application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Davis, Nathan; Johnson, Brian; McJunkin, Timothy
This paper presents a demand response model for a hypothetical microgrid that integrates renewable resources and plug-in electric vehicle (PEV) charging systems. It is assumed that the microgrid has black start capability and that external generation is available for purchase while grid connected to satisfy additional demand. The microgrid is developed such that in addition to renewable, non-dispatchable generation from solar, wind and run of the river hydroelectric resources, local dispatchable generation is available in the form of small hydroelectric and moderately sized gas and coal fired facilities. To accurately model demand, the load model is separated into independent residential,more » commercial, industrial, and PEV charging systems. These are dispatched and committed based on a mixed integer linear program developed to minimize the cost of generation and load shedding while satisfying constraints associated with line limits, conservation of energy, and ramp rates of the generation units. The model extends a research tool to longer time frames intended for policy setting and educational environments and provides a realistic and intuitive understanding of beneficial and challenging aspects of electrification of vehicles combined with integration of green electricity production.« less
Transmission dispatch and congestion management in open market systems
NASA Astrophysics Data System (ADS)
Fang, Risheng
This thesis is located in the domain of electricity supply industry restructuring. It deals with emerging issues, whose understanding is essential to advancing knowledge of open access transmission theory and proceeds to develop approaches for solving the transmission dispatch and congestion management problem. An overview of current trends and experiences in utility restructuring and the main models for restructuring, as well as the classifications of system operators, is first presented. A fully unbundled competitive electricity market model, called the bilateral/multilateral trades model, is then developed. A survey of current research in transmission dispatch and congestion management is included with discussion of transmission capacity and ancillary services. A methodology for the power dispatch problem in a structure dominated by bilateral and multilateral transmission contracts is presented. Group structures are mathematically formulated and explored and three basic types of curtailment strategies proposed for use by market participants. A more complex model is then developed, which takes into account the co-existence of bilateral and multilateral contracts with pool type dynamic supplies and demands based on bids and market clearing prices. An integrated dispatch strategy to reconcile all three types of transactions (bilateral, multilateral and pool) is then developed. Prioritization of electricity transactions and related curtailment strategies are explored and a mechanism for coordination between market participants to achieve additional economic advantages is described. A theory of security based rescheduling is presented in order to investigate the security-related aspects of operation in an unbundled and deregulated system. The impact of post-contingency corrective capability on optimal rescheduling results has been identified and the advantage of incorporating post-contingency corrective rescheduling into the objective function demonstrated. Finally, integrated congestion management procedures in real-time system operation and in forward energy markets are developed. Market price response and coordination of dispatch by the ISO are incorporated to achieve an overall strategy.
Near-term implications of a ban on new coal-fired power plants in the United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adam Newcomer; Jay Apt
2009-06-15
Large numbers of proposed new coal power generators in the United States have been cancelled, and some states have prohibited new coal power generators. We examine the effects on the U.S. electric power system of banning the construction of coal-fired electricity generators, which has been proposed as a means to reduce U.S. CO{sub 2} emissions. The model simulates load growth, resource planning, and economic dispatch of the Midwest Independent Transmission System Operator (ISO), Inc., Electric Reliability Council of Texas (ERCOT), and PJM under a ban on new coal generation and uses an economic dispatch model to calculate the resulting changesmore » in dispatch order, CO{sub 2} emissions, and fuel use under three near-term (until 2030) future electric power sector scenarios. A national ban on new coal-fired power plants does not lead to CO{sub 2} reductions of the scale required under proposed federal legislation such as Lieberman-Warner but would greatly increase the fraction of time when natural gas sets the price of electricity, even with aggressive wind and demand response policies. 50 refs., 5 figs., 4 tabs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhou, Shengru; Hurlbut, David J; Li, Ma
In recent years, the US electricity market has undergone several stages of reform, and gradually formed the market where the wholesale electricity price is determined by the supply and demand. The US electricity market also changes along with the rapid development of clean energy, forming a number of the market mechanisms that is specifically developed for clean energy power generation characteristics. On the basis of discussing the pricing mechanism of US electricity market, this paper analyzes the experience and practice of encouraging renewable energy development policy and clean energy dispatch from the angle of market mechanism and dispatching decision, andmore » puts forward the reference for clean energy dispatching in China.« less
Optimized dispatch in a first-principles concentrating solar power production model
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wagner, Michael J.; Newman, Alexandra M.; Hamilton, William T.
Concentrating solar power towers, which include a steam-Rankine cycle with molten salt thermal energy storage, is an emerging technology whose maximum effectiveness relies on an optimal operational and dispatch policy. Given parameters such as start-up and shut-down penalties, expected electricity price profiles, solar availability, and system interoperability requirements, this paper seeks a profit-maximizing solution that determines start-up and shut-down times for the power cycle and solar receiver, and the times at which to dispatch stored and instantaneous quantities of energy over a 48-h horizon at hourly fidelity. The mixed-integer linear program (MIP) is subject to constraints including: (i) minimum andmore » maximum rates of start-up and shut-down, (ii) energy balance, including energetic state of the system as a whole and its components, (iii) logical rules governing the operational modes of the power cycle and solar receiver, and (iv) operational consistency between time periods. The novelty in this work lies in the successful integration of a dispatch optimization model into a detailed techno-economic analysis tool, specifically, the National Renewable Energy Laboratory's System Advisor Model (SAM). The MIP produces an optimized operating strategy, historically determined via a heuristic. Using several market electricity pricing profiles, we present comparative results for a system with and without dispatch optimization, indicating that dispatch optimization can improve plant profitability by 5-20% and thereby alter the economics of concentrating solar power technology. While we examine a molten salt power tower system, this analysis is equally applicable to the more mature concentrating solar parabolic trough system with thermal energy storage.« less
NASA Astrophysics Data System (ADS)
Nanaeda, Kimihiro; Mueller, Fabian; Brouwer, Jacob; Samuelsen, Scott
Operating strategies of solid oxide fuel cell (SOFC) combined heat and power (CHP) systems are developed and evaluated from a utility, and end-user perspective using a fully integrated SOFC-CHP system dynamic model that resolves the physical states, thermal integration and overall efficiency of the system. The model can be modified for any SOFC-CHP system, but the present analysis is applied to a hotel in southern California based on measured electric and heating loads. Analysis indicates that combined heat and power systems can be operated to benefit both the end-users and the utility, providing more efficient electric generation as well as grid ancillary services, namely dispatchable urban power. Design and operating strategies considered in the paper include optimal sizing of the fuel cell, thermal energy storage to dispatch heat, and operating the fuel cell to provide flexible grid power. Analysis results indicate that with a 13.1% average increase in price-of-electricity (POE), the system can provide the grid with a 50% operating range of dispatchable urban power at an overall thermal efficiency of 80%. This grid-support operating mode increases the operational flexibility of the SOFC-CHP system, which may make the technology an important utility asset for accommodating the increased penetration of intermittent renewable power.
Electricity Market Module - NEMS Documentation
2017-01-01
Documents the Electricity Market Module as it was used for the Annual Energy Outlook. The Electricity Market Module (EMM) is the electricity supply component of the National Energy Modeling System (NEMS). The EMM represents the generation, transmission, and pricing of electricity. It consists of four submodules: the Electricity Capacity Planning (ECP) Submodule, the Electricity Fuel Dispatch (EFD) Submodule, the Electricity Finance and Pricing (EFP) Submodule, and the Electricity Load and Demand (ELD) Submodule.
Sanders, Kelly T; Blackhurst, Michael F; King, Carey W; Webber, Michael E
2014-06-17
We utilize a unit commitment and dispatch model to estimate how water use fees on power generators would affect dispatching and water requirements by the power sector in the Electric Reliability Council of Texas' (ERCOT) electric grid. Fees ranging from 10 to 1000 USD per acre-foot were separately applied to water withdrawals and consumption. Fees were chosen to be comparable in cost to a range of water supply projects proposed in the Texas Water Development Board's State Water Plan to meet demand through 2050. We found that these fees can reduce water withdrawals and consumption for cooling thermoelectric power plants in ERCOT by as much as 75% and 23%, respectively. To achieve these water savings, wholesale electricity generation costs might increase as much as 120% based on 2011 fuel costs and generation characteristics. We estimate that water saved through these fees is not as cost-effective as conventional long-term water supply projects. However, the electric grid offers short-term flexibility that conventional water supply projects do not. Furthermore, this manuscript discusses conditions under which the grid could be effective at "supplying" water, particularly during emergency drought conditions, by changing its operational conditions.
Secure provision of reactive power ancillary services in competitive electricity markets
NASA Astrophysics Data System (ADS)
El-Samahy, Ismael
The research work presented in this thesis discusses various complex issues associated with reactive power management and pricing in the context of new operating paradigms in deregulated power systems, proposing appropriate policy solutions. An integrated two-level framework for reactive power management is set forth, which is both suitable for a competitive market and ensures a secure and reliable operation of the associated power system. The framework is generic in nature and can be adopted for any electricity market structure. The proposed hierarchical reactive power market structure comprises two stages: procurement of reactive power resources on a seasonal basis, and real-time reactive power dispatch. The main objective of the proposed framework is to provide appropriate reactive power support from service providers at least cost, while ensuring a secure operation of the power system. The proposed procurement procedure is based on a two-step optimization model. First, the marginal benefits of reactive power supply from each provider, with respect to system security, are obtained by solving a loadability-maximization problem subject to transmission security constraints imposed by voltage and thermal limits. Second, the selected set of generators is determined by solving an optimal power flow (OPF)-based auction. This auction maximizes a societal advantage function comprising generators' offers and their corresponding marginal benefits with respect to system security, and considering all transmission system constraints. The proposed procedure yields the selected set of generators and zonal price components, which would form the basis for seasonal contracts between the system operator and the selected reactive power service providers. The main objective of the proposed reactive power dispatch model is to minimize the total payment burden on the Independent System Operator (ISO), which is associated with reactive power dispatch. The real power generation is decoupled and assumed to be fixed during the reactive power dispatch procedures; however, the effect of reactive power on real power is considered in the model by calculating the required reduction in real power output of a generator due to an increase in its reactive power supply. In this case, real power generation is allowed to be rescheduled, within given limits, from the already dispatched levels obtained from the energy market clearing process. The proposed dispatch model achieves the main objective of an ISO in a competitive electricity market, which is to provide the required reactive power support from generators at least cost while ensuring a secure operation of the power system. The proposed reactive power procurement and dispatch models capture both the technical and economic aspects of power system operation in competitive electricity markets; however, from an optimization point of view, these models represent non-convex mixed integer non-linear programming (MINLP) problems due to the presence of binary variables associated with the different regions of reactive power operation in a synchronous generator. Such MINLP optimization problems are difficult to solve, especially for an actual power system. A novel Generator Reactive Power Classification (GRPC) algorithm is proposed in this thesis to address this issue, with the advantage of iteratively solving the optimization models as a series of non-linear programming (NLP) sub-problems. The proposed reactive power procurement and dispatch models are implemented and tested on the CIGRE 32-bus system, with several case studies that represent different practical operating scenarios. The developed models are also compared with other approaches for reactive power provision, and the results demonstrate the robustness and effectiveness of the proposed model. The results clearly reveal the main features of the proposed models for optimal provision of reactive power ancillary service, in order to suit the requirements of an ISO under today's stressed system conditions in a competitive market environment.
Robust optimization-based DC optimal power flow for managing wind generation uncertainty
NASA Astrophysics Data System (ADS)
Boonchuay, Chanwit; Tomsovic, Kevin; Li, Fangxing; Ongsakul, Weerakorn
2012-11-01
Integrating wind generation into the wider grid causes a number of challenges to traditional power system operation. Given the relatively large wind forecast errors, congestion management tools based on optimal power flow (OPF) need to be improved. In this paper, a robust optimization (RO)-based DCOPF is proposed to determine the optimal generation dispatch and locational marginal prices (LMPs) for a day-ahead competitive electricity market considering the risk of dispatch cost variation. The basic concept is to use the dispatch to hedge against the possibility of reduced or increased wind generation. The proposed RO-based DCOPF is compared with a stochastic non-linear programming (SNP) approach on a modified PJM 5-bus system. Primary test results show that the proposed DCOPF model can provide lower dispatch cost than the SNP approach.
DYNAMIC ELECTRICITY GENERATION FOR ADDRESSING DAILY AIR QUALITY EXCEEDANCES IN THE US
We will design, demonstrate, and evaluate a dynamic management system for managing daily air quality, exploring different elements of the design of this system such as how air quality forecasts can best be used, and decision rules for the electrical dispatch model. We will ...
NASA Astrophysics Data System (ADS)
Peer, R.; Sanders, K.
2017-12-01
The optimization function that governs the dispatching of power generators to meet electricity demand minimizes the marginal cost of electricity generation without regard to the environmental or public health damages caused by power production. Although technologies exist for reducing the externalities resulting from electricity generation at power plants, current solutions typically raise the cost of power production or introduce operational challenges for the grid. This research quantifies the trade-offs and couplings between the cooling water, greenhouse gas emissions, and air quality impacts of different power generating technologies under business as usual market conditions, as well as a series of market-based interventions aimed to reduce the production of those externalities. Using publicly available data from the US Environmental Protection Agency (EPA) and the US Energy Information Administration (EIA) for power plant water use and emissions, a unit commitment and dispatch power market simulation model is modified to evaluate the production of environmental externalities from power production. Scenarios are developed to apply a set of fees for cooling water, carbon dioxide, nitrous oxide and sulfur oxide emissions, respectively. Trade-offs between environmental performance, overall generation costs, and shifts in the power plants dispatched to meet demand are quantified for each power market simulation. The results from this study will provide insight into the development of a novel market-based framework that modifies the optimization algorithms governing the dispatching of electricity onto the grid in efforts to achieve cost-effective improvements in its environmental performance without the need for new infrastructure investments.
NASA Astrophysics Data System (ADS)
Flores, Robert Joseph
Distributed generation can provide many benefits over traditional central generation such as increased reliability and efficiency while reducing emissions. Despite these potential benefits, distributed generation is generally not purchased unless it reduces energy costs. Economic dispatch strategies can be designed such that distributed generation technologies reduce overall facility energy costs. In this thesis, a microturbine generator is dispatched using different economic control strategies, reducing the cost of energy to the facility. Several industrial and commercial facilities are simulated using acquired electrical, heating, and cooling load data. Industrial and commercial utility rate structures are modeled after Southern California Edison and Southern California Gas Company tariffs and used to find energy costs for the simulated buildings and corresponding microturbine dispatch. Using these control strategies, building models, and utility rate models, a parametric study examining various generator characteristics is performed. An economic assessment of the distributed generation is then performed for both the microturbine generator and parametric study. Without the ability to export electricity to the grid, the economic value of distributed generation is limited to reducing the individual costs that make up the cost of energy for a building. Any economic dispatch strategy must be built to reduce these individual costs. While the ability of distributed generation to reduce cost depends of factors such as electrical efficiency and operations and maintenance cost, the building energy demand being serviced has a strong effect on cost reduction. Buildings with low load factors can accept distributed generation with higher operating costs (low electrical efficiency and/or high operations and maintenance cost) due to the value of demand reduction. As load factor increases, lower operating cost generators are desired due to a larger portion of the building load being met in an effort to reduce demand. In addition, buildings with large thermal demand have access to the least expensive natural gas, lowering the cost of operating distributed generation. Recovery of exhaust heat from DG reduces cost only if the buildings thermal demand coincides with the electrical demand. Capacity limits exist where annual savings from operation of distributed generation decrease if further generation is installed. For low operating cost generators, the approximate limit is the average building load. This limit decreases as operating costs increase. In addition, a high capital cost of distributed generation can be accepted if generator operating costs are low. As generator operating costs increase, capital cost must decrease if a positive economic performance is desired.
Effects of plug-in hybrid electric vehicles on ozone concentrations in Colorado.
Brinkman, Gregory L; Denholm, Paul; Hannigan, Michael P; Milford, Jana B
2010-08-15
This study explores how ozone concentrations in the Denver, CO area might have been different if plug-in hybrid electric vehicles (PHEVs) had replaced light duty gasoline vehicles in summer 2006. A unit commitment and dispatch model was used to estimate the charging patterns of PHEVs and dispatch power plants to meet electricity demand. Emission changes were estimated based on gasoline displacement and the emission characteristics of the power plants providing additional electricity. The Comprehensive Air Quality Model with extensions (CAMx) was used to simulate the effects of these emissions changes on ozone concentrations. Natural gas units provided most of the electricity used for charging PHEVs in the scenarios considered. With 100% PHEV penetration, nitrogen oxide (NO(x)) emissions were reduced by 27 tons per day (tpd) from a fleet of 1.7 million vehicles and were increased by 3 tpd from power plants; VOC emissions were reduced by 57 tpd. These emission changes reduced modeled peak 8-h average ozone concentrations by approximately 2-3 ppb on most days. Ozone concentration increases were modeled for small areas near central Denver. Future research is needed to forecast when significant PHEV penetration may occur and to anticipate characteristics of the corresponding power plant and vehicle fleets.
78 FR 63172 - Commission Information Collection Activities (FERC-733); Comment Request
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-23
... Electric Reliability Corporation (NERC) and EIA, to fielding and collecting data using a FERC designed... Commission in time to complete the 2014 report to Congress. NERC, as the Electric Reliability Organization... dispatchable and non-dispatchable resources that it needs to conduct its reliability work. Reporting demand...
Emissions impacts and benefits of plug-in hybrid electric vehicles and vehicle-to-grid services
Sioshansi, Ramteen; Denholm, Paul
2009-01-22
Plug-in hybrid electric vehicles (PHEVs) have been promoted as a potential technology to reduce emissions of greenhouse gases and other pollutants by using electricity instead of petroleum, and by improving electric system efficiency by providing vehicle-to-grid (V2G) services. We use an electric power system model to explicitly evaluate the change in generator dispatches resulting from PHEV deployment in the Texas grid, and apply fixed and non-parametric estimates of generator emissions rates, to estimate the resulting changes in generation emissions. Here, we find that by using the flexibility of when vehicles may be charged, generator efficiency can be increased substantially. Bymore » changing generator dispatch, a PHEV fleet of up to 15% of light-duty vehicles can actually decrease net generator NO x emissions during the ozone season, despite the additional charging load. By adding V2G services, such as spinning reserves and energy storage, CO 2, SO 2, and NO x emissions can be reduced even further.« less
Emissions impacts and benefits of plug-in hybrid electric vehicles and vehicle-to-grid services.
Sioshansi, Ramteen; Denholm, Paul
2009-02-15
Plug-in hybrid electric vehicles (PHEVs) have been promoted as a potential technology to reduce emissions of greenhouse gases and other pollutants by using electricity instead of petroleum, and byimproving electric system efficiency by providing vehicle-to-grid (V2G) services. We use an electric power system model to explicitly evaluate the change in generator dispatches resulting from PHEV deployment in the Texas grid, and apply fixed and non-parametric estimates of generator emissions rates, to estimate the resulting changes in generation emissions. We find that by using the flexibility of when vehicles may be charged, generator efficiency can be increased substantially. By changing generator dispatch, a PHEVfleet of up to 15% of light-duty vehicles can actually decrease net generator NOx emissions during the ozone season, despite the additional charging load. By adding V2G services, such as spinning reserves and energy storage, CO2, SO2, and NOx emissions can be reduced even further.
NASA Astrophysics Data System (ADS)
Bolorinos, J.; Ajami, N.; Yu, Y.; Rajagopal, R.
2016-12-01
Urban water supply and energy systems in the arid Southwestern United States are closely linked. Freshwater use by the electricity sector in particular represents a sizable portion of total water consumption in the region. Nonetheless, the dispatch of water and energy resources is managed separately, and no research to-date has examined the water conservation potential presented by the electricity sector. This study gauges the potential water savings that could be achieved including water use in the power dispatch process in Southern California by simulating a DC Optimal Power Flow for a simplified model of the region's power network. The simulation uses historical power consumption data, historical power production data and water use data from the US Geological Survey, the California Energy Commission and the US Energy Information Administration to estimate freshwater consumption by the region's thermoelectric power generation fleet. Preliminary results indicate that power system freshwater consumption could be reduced by as much as 20% at a minimal cost penalty, with potential for even greater savings. Model results show that Southern California's power system has the ability to competitively shift the use of some of the region's water resources from electricity to urban consumption, and suggests that water use should be incorporated into the policy-making process to enhance the efficient use of the state's interconnected water and energy resources.
Johnson, T L; Keith, D W
2001-10-01
The decoupling of fossil-fueled electricity production from atmospheric CO2 emissions via CO2 capture and sequestration (CCS) is increasingly regarded as an important means of mitigating climate change at a reasonable cost. Engineering analyses of CO2 mitigation typically compare the cost of electricity for a base generation technology to that for a similar plant with CO2 capture and then compute the carbon emissions mitigated per unit of cost. It can be hard to interpret mitigation cost estimates from this plant-level approach when a consistent base technology cannot be identified. In addition, neither engineering analyses nor general equilibrium models can capture the economics of plant dispatch. A realistic assessment of the costs of carbon sequestration as an emissions abatement strategy in the electric sector therefore requires a systems-level analysis. We discuss various frameworks for computing mitigation costs and introduce a simplified model of electric sector planning. Results from a "bottom-up" engineering-economic analysis for a representative U.S. North American Electric Reliability Council (NERC) region illustrate how the penetration of CCS technologies and the dispatch of generating units vary with the price of carbon emissions and thereby determine the relationship between mitigation cost and emissions reduction.
Johnson, Timothy L; Keith, David W
2001-10-01
The decoupling of fossil-fueled electricity production from atmospheric CO 2 emissions via CO 2 capture and sequestration (CCS) is increasingly regarded as an important means of mitigating climate change at a reasonable cost. Engineering analyses of CO 2 mitigation typically compare the cost of electricity for a base generation technology to that for a similar plant with CO 2 capture and then compute the carbon emissions mitigated per unit of cost. It can be hard to interpret mitigation cost estimates from this plant-level approach when a consistent base technology cannot be identified. In addition, neither engineering analyses nor general equilibrium models can capture the economics of plant dispatch. A realistic assessment of the costs of carbon sequestration as an emissions abatement strategy in the electric sector therefore requires a systems-level analysis. We discuss various frameworks for computing mitigation costs and introduce a simplified model of electric sector planning. Results from a "bottom-up" engineering-economic analysis for a representative U.S. North American Electric Reliability Council (NERC) region illustrate how the penetration of CCS technologies and the dispatch of generating units vary with the price of carbon emissions and thereby determine the relationship between mitigation cost and emissions reduction.
NASA Astrophysics Data System (ADS)
Wahyuda; Santosa, Budi; Rusdiansyah, Ahmad
2018-04-01
Deregulation of the electricity market requires coordination between parties to synchronize the optimization on the production side (power station) and the transport side (transmission). Electricity supply chain presented in this article is designed to facilitate the coordination between the parties. Generally, the production side is optimized with price based dynamic economic dispatch (PBDED) model, while the transmission side is optimized with Multi-echelon distribution model. Both sides optimization are done separately. This article proposes a joint model of PBDED and multi-echelon distribution for the combined optimization of production and transmission. This combined optimization is important because changes in electricity demand on the customer side will cause changes to the production side that automatically also alter the transmission path. The transmission will cause two cost components. First, the cost of losses. Second, the cost of using the transmission network (wheeling transaction). Costs due to losses are calculated based on ohmic losses, while the cost of using transmission lines using the MW - mile method. As a result, this method is able to provide best allocation analysis for electrical transactions, as well as emission levels in power generation and cost analysis. As for the calculation of transmission costs, the Reverse MW-mile method produces a cheaper cost than the Absolute MW-mile method
Implications of near-term coal power plant retirement for SO2 and NOX and life cycle GHG emissions.
Venkatesh, Aranya; Jaramillo, Paulina; Griffin, W Michael; Matthews, H Scott
2012-09-18
Regulations monitoring SO(2), NO(X), mercury, and other metal emissions in the U.S. will likely result in coal plant retirement in the near-term. Life cycle assessment studies have previously estimated the environmental benefits of displacing coal with natural gas for electricity generation, by comparing systems that consist of individual natural gas and coal power plants. However, such system comparisons may not be appropriate to analyze impacts of coal plant retirement in existing power fleets. To meet this limitation, simplified economic dispatch models for PJM, MISO, and ERCOT regions are developed in this study to examine changes in regional power plant dispatch that occur when coal power plants are retired. These models estimate the order in which existing power plants are dispatched to meet electricity demand based on short-run marginal costs, with cheaper plants being dispatched first. Five scenarios of coal plant retirement are considered: retiring top CO(2) emitters, top NO(X) emitters, top SO(2) emitters, small and inefficient plants, and old and inefficient plants. Changes in fuel use, life cycle greenhouse gas emissions (including uncertainty), and SO(2) and NO(X) emissions are estimated. Life cycle GHG emissions were found to decrease by less than 4% in almost all scenarios modeled. In addition, changes in marginal damage costs due to SO(2), and NO(X) emissions are estimated using the county level marginal damage costs reported in the Air Pollution Emissions Experiments and Policy (APEEP) model, which are a proxy for measuring regional impacts of SO(2) and NO(X) emissions. Results suggest that location specific parameters should be considered within environmental policy frameworks targeting coal plant retirement, to account for regional variability in the benefits of reducing the impact of SO(2) and NO(X) emissions.
Marginal Loss Calculations for the DCOPF
DOE Office of Scientific and Technical Information (OSTI.GOV)
Eldridge, Brent; O'Neill, Richard P.; Castillo, Andrea R.
2016-12-05
The purpose of this paper is to explain some aspects of including a marginal line loss approximation in the DCOPF. The DCOPF optimizes electric generator dispatch using simplified power flow physics. Since the standard assumptions in the DCOPF include a lossless network, a number of modifications have to be added to the model. Calculating marginal losses allows the DCOPF to optimize the location of power generation, so that generators that are closer to demand centers are relatively cheaper than remote generation. The problem formulations discussed in this paper will simplify many aspects of practical electric dispatch implementations in use today,more » but will include sufficient detail to demonstrate a few points with regard to the handling of losses.« less
Solar Thermoelectricity via Advanced Latent Heat Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Olsen, Michele L.; Rea, J.; Glatzmaier, Greg C.
2016-05-31
We report on a new modular, dispatchable, and cost-effective solar electricity-generating technology. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) integrates several state-of-the-art technologies to provide electricity on demand. In the envisioned STEALS system, concentrated sunlight is converted to heat at a solar absorber. The heat is then delivered to either a thermoelectric (TE) module for direct electricity generation, or to charge a phase change material for thermal energy storage, enabling subsequent generation during off-sun hours, or both for simultaneous electricity production and energy storage. The key to making STEALS a dispatchable technology lies in the development of a 'thermalmore » valve,' which controls when heat is allowed to flow through the TE module, thus controlling when electricity is generated. The current project addresses each of the three major subcomponents, (i) the TE module, (ii) the thermal energy storage system, and (iii) the thermal valve. The project also includes system-level and techno- economic modeling of the envisioned integrated system and will culminate in the demonstration of a laboratory-scale STEALS prototype capable of generating 3kWe.« less
Solar thermoelectricity via advanced latent heat storage
NASA Astrophysics Data System (ADS)
Olsen, M. L.; Rea, J.; Glatzmaier, G. C.; Hardin, C.; Oshman, C.; Vaughn, J.; Roark, T.; Raade, J. W.; Bradshaw, R. W.; Sharp, J.; Avery, A. D.; Bobela, D.; Bonner, R.; Weigand, R.; Campo, D.; Parilla, P. A.; Siegel, N. P.; Toberer, E. S.; Ginley, D. S.
2016-05-01
We report on a new modular, dispatchable, and cost-effective solar electricity-generating technology. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) integrates several state-of-the-art technologies to provide electricity on demand. In the envisioned STEALS system, concentrated sunlight is converted to heat at a solar absorber. The heat is then delivered to either a thermoelectric (TE) module for direct electricity generation, or to charge a phase change material for thermal energy storage, enabling subsequent generation during off-sun hours, or both for simultaneous electricity production and energy storage. The key to making STEALS a dispatchable technology lies in the development of a "thermal valve," which controls when heat is allowed to flow through the TE module, thus controlling when electricity is generated. The current project addresses each of the three major subcomponents, (i) the TE module, (ii) the thermal energy storage system, and (iii) the thermal valve. The project also includes system-level and techno- economic modeling of the envisioned integrated system and will culminate in the demonstration of a laboratory-scale STEALS prototype capable of generating 3kWe.
Solar electricity supply isolines of generation capacity and storage.
Grossmann, Wolf; Grossmann, Iris; Steininger, Karl W
2015-03-24
The recent sharp drop in the cost of photovoltaic (PV) electricity generation accompanied by globally rapidly increasing investment in PV plants calls for new planning and management tools for large-scale distributed solar networks. Of major importance are methods to overcome intermittency of solar electricity, i.e., to provide dispatchable electricity at minimal costs. We find that pairs of electricity generation capacity G and storage S that give dispatchable electricity and are minimal with respect to S for a given G exhibit a smooth relationship of mutual substitutability between G and S. These isolines between G and S support the solving of several tasks, including the optimal sizing of generation capacity and storage, optimal siting of solar parks, optimal connections of solar parks across time zones for minimizing intermittency, and management of storage in situations of far below average insolation to provide dispatchable electricity. G-S isolines allow determining the cost-optimal pair (G,S) as a function of the cost ratio of G and S. G-S isolines provide a method for evaluating the effect of geographic spread and time zone coverage on costs of solar electricity.
Solar electricity supply isolines of generation capacity and storage
Grossmann, Wolf; Grossmann, Iris; Steininger, Karl W.
2015-01-01
The recent sharp drop in the cost of photovoltaic (PV) electricity generation accompanied by globally rapidly increasing investment in PV plants calls for new planning and management tools for large-scale distributed solar networks. Of major importance are methods to overcome intermittency of solar electricity, i.e., to provide dispatchable electricity at minimal costs. We find that pairs of electricity generation capacity G and storage S that give dispatchable electricity and are minimal with respect to S for a given G exhibit a smooth relationship of mutual substitutability between G and S. These isolines between G and S support the solving of several tasks, including the optimal sizing of generation capacity and storage, optimal siting of solar parks, optimal connections of solar parks across time zones for minimizing intermittency, and management of storage in situations of far below average insolation to provide dispatchable electricity. G−S isolines allow determining the cost-optimal pair (G,S) as a function of the cost ratio of G and S. G−S isolines provide a method for evaluating the effect of geographic spread and time zone coverage on costs of solar electricity. PMID:25755261
NASA Astrophysics Data System (ADS)
Schwaiger, Karl; Haider, Markus; Haemmerle, Martin; Steiner, Peter; Obermaier, Michael-Dario
2016-05-01
Flexible dispatch able solar thermal electricity plants applying state of the art power cycles have the potential of playing a vital role in modern electricity systems and even participating in the ancillary market. By replacing molten salt via particles, operation temperatures can be increased and plant efficiencies of over 45 % can be reached. In this work the concept for a utility scale plant using corundum as storage/heat transfer material is thermodynamically modeled and its key performance data are cited. A novel indirect fluidized bed particle receiver concept is presented, profiting from a near black body behavior being able to heat up large particle flows by realizing temperature cycles over 500°C. Specialized fluidized bed steam-generators are applied with negligible auxiliary power demand. The performance of the key components is discussed and a rough sketch of the plant is provided.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sullivan, P.; Eurek, K.; Margolis, R.
2014-07-01
Because solar power is a rapidly growing component of the electricity system, robust representations of solar technologies should be included in capacity-expansion models. This is a challenge because modeling the electricity system--and, in particular, modeling solar integration within that system--is a complex endeavor. This report highlights the major challenges of incorporating solar technologies into capacity-expansion models and shows examples of how specific models address those challenges. These challenges include modeling non-dispatchable technologies, determining which solar technologies to model, choosing a spatial resolution, incorporating a solar resource assessment, and accounting for solar generation variability and uncertainty.
Emissions implications of downscaled electricity generation scenarios for the western United States
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nsanzineza, Rene; O’Connell, Matthew; Brinkman, Gregory
This study explores how emissions from electricity generation in the Western Interconnection region of the U.S. might respond in circa 2030 to contrasting scenarios for fuel prices and greenhouse gas (GHG) emissions fees. We examine spatial and temporal variations in generation mix across the region and year using the PLEXOS unit commitment and dispatch model with a production cost model database adapted from the Western Electricity Coordinating Council. Emissions estimates are computed by combining the dispatch model results with unit-specific, emissions-load relationships. Wind energy displaces natural gas and coal in scenarios with relatively expensive natural gas or with GHG fees.more » Correspondingly, annual emissions of NOx, SO2, and CO2 are reduced by 20-40% in these cases. NOx emissions, which are a concern as a precursor of ground-level ozone, are relatively high and consistent across scenarios during summer, when peak electricity loads occur and wind resources in the region are comparatively weak. Accounting for the difference in start-up versus stabilized NOx emissions rates for natural gas plants had little impact on region-wide emissions estimates due to the dominant contribution from coal-fired plants, but would be more important in the vicinity of the natural gas units.« less
System-wide emissions implications of increased wind power penetration.
Valentino, Lauren; Valenzuela, Viviana; Botterud, Audun; Zhou, Zhi; Conzelmann, Guenter
2012-04-03
This paper discusses the environmental effects of incorporating wind energy into the electric power system. We present a detailed emissions analysis based on comprehensive modeling of power system operations with unit commitment and economic dispatch for different wind penetration levels. First, by minimizing cost, the unit commitment model decides which thermal power plants will be utilized based on a wind power forecast, and then, the economic dispatch model dictates the level of production for each unit as a function of the realized wind power generation. Finally, knowing the power production from each power plant, the emissions are calculated. The emissions model incorporates the effects of both cycling and start-ups of thermal power plants in analyzing emissions from an electric power system with increasing levels of wind power. Our results for the power system in the state of Illinois show significant emissions effects from increased cycling and particularly start-ups of thermal power plants. However, we conclude that as the wind power penetration increases, pollutant emissions decrease overall due to the replacement of fossil fuels.
Yu, Yang; Rajagopal, Ram
2015-02-17
Two dispatch protocols have been adopted by electricity markets to deal with the uncertainty of wind power but the effects of the selection between the dispatch protocols have not been comprehensively analyzed. We establish a framework to compare the impacts of adopting different dispatch protocols on the efficacy of using wind power and implementing a carbon tax to reduce emissions. We suggest that a market has high potential to achieve greater emission reduction by adopting the stochastic dispatch protocol instead of the static protocol when the wind energy in the market is highly uncertain or the market has enough adjustable generators, such as gas-fired combustion generators. Furthermore, the carbon-tax policy is more cost-efficient for reducing CO2 emission when the market operates according to the stochastic protocol rather than the static protocol. An empirical study, which is calibrated according to the data from the Electric Reliability Council of Texas market, confirms that using wind energy in the Texas market results in a 12% CO2 emission reduction when the market uses the stochastic dispatch protocol instead of the 8% emission reduction associated with the static protocol. In addition, if a 6$/ton carbon tax is implemented in the Texas market operated according to the stochastic protocol, the CO2 emission is similar to the emission level from the same market with a 16$/ton carbon tax operated according to the static protocol. Correspondingly, the 16$/ton carbon tax associated with the static protocol costs 42.6% more than the 6$/ton carbon tax associated with the stochastic protocol.
Evaluating the CO 2 emissions reduction potential and cost of power sector re-dispatch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steinberg, Daniel C.; Bielen, David A.; Townsend, Aaron
Prior studies of the U.S. electricity sector have recognized the potential to reduce carbon dioxide (CO2) emissions by substituting generation from coal-fired units with generation from under-utilized and lower-emitting natural gas-fired units; in fact, this type of 're-dispatch' was invoked as one of the three building blocks used to set the emissions targets under the Environmental Protection Agency's Clean Power Plan. Despite the existence of surplus natural gas capacity in the U.S., power system operational constraints not often considered in power sector policy analyses, such as transmission congestion, generator ramping constraints, minimum generation constraints, planned and unplanned generator outages, andmore » ancillary service requirements, could limit the potential and increase the cost of coal-to-gas re-dispatch. Using a highly detailed power system unit commitment and dispatch model, we estimate the maximum potential for re-dispatch in the Eastern Interconnection, which accounts for the majority of coal capacity and generation in the U.S. Under our reference assumptions, we find that maximizing coal-to-gas re-dispatch yields emissions reductions of 230 million metric tons (Mt), or 13% of power sector emissions in the Eastern Interconnection, with a corresponding average abatement cost of $15-$44 per metric ton of CO2, depending on the assumed supply elasticity of natural gas.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jorgenson, Jennie; Denholm, Paul; Mehos, Mark
2013-12-01
Concentrating solar power with thermal energy storage (CSP-TES) is a unique source of renewable energy in that the solar thermal energy can be dispatched similarly to conventional thermal generation. However, CSP-TES plants are energy-limited, meaning that their response might be restricted by solar availability. Therefore, the use of this limited solar energy must be optimally scheduled toprovide the greatest value to the system. The timing of CSP-TES dispatch depends on a variety of factors, including electricity demand patterns, the penetration of variable generation sources, and the configuration of the CSP-TES plant itself. We use an established CSP-TES modeling framework inmore » a commercially available production cost model to compare the dispatch and value of two CSP-TEStechnologies (molten salt towers and parabolic troughs) in a Colorado test system. In addition, we consider a range of configuration parameters, such as the solar multiple and thermal energy storage limit, to evaluate how the operational and capacity value varies with plant configuration.« less
Hybrid robust predictive optimization method of power system dispatch
Chandra, Ramu Sharat [Niskayuna, NY; Liu, Yan [Ballston Lake, NY; Bose, Sumit [Niskayuna, NY; de Bedout, Juan Manuel [West Glenville, NY
2011-08-02
A method of power system dispatch control solves power system dispatch problems by integrating a larger variety of generation, load and storage assets, including without limitation, combined heat and power (CHP) units, renewable generation with forecasting, controllable loads, electric, thermal and water energy storage. The method employs a predictive algorithm to dynamically schedule different assets in order to achieve global optimization and maintain the system normal operation.
DOE Office of Scientific and Technical Information (OSTI.GOV)
BARTONE, ERIK
DBS Energy Inc. (“DBS”) intends on using the Connecticut Biofuels Technology Project for the purpose of developing a small-scale electric generating systems that are located on a distributed basis and utilize biodiesel as its principle fuel source. This project will include research and analysis on the quality and applied use of biodiesel for use in electricity production, 2) develop dispatch center for testing and analysis of the reliability of dispatching remote generators operating on a blend of biodiesel and traditional fossil fuels, and 3) analysis and engineering research on fuel storage options for biodiesel of fuels for electric generation.
NASA Astrophysics Data System (ADS)
Duran, P.; Holloway, T.; Brinkman, G.; Denholm, P.; Littlefield, C. M.
2011-12-01
Solar photovoltaics (PV) are an attractive technology because they can be locally deployed and tend to yield high production during periods of peak electric demand. These characteristics can reduce the need for conventional large-scale electricity generation, thereby reducing emissions of criteria air pollutants (CAPs) and improving ambient air quality with regard to such pollutants as nitrogen oxides, sulfur oxides and fine particulates. Such effects depend on the local climate, time-of-day emissions, available solar resources, the structure of the electric grid, and existing electricity production among other factors. This study examines the air quality impacts of distributed PV across the United States Eastern Interconnection. In order to accurately model the air quality impact of distributed PV in space and time, we used the National Renewable Energy Lab's (NREL) Regional Energy Deployment System (ReEDS) model to form three unique PV penetration scenarios in which new PV construction is distributed spatially based upon economic drivers and natural solar resources. Those scenarios are 2006 Eastern Interconnection business as usual, 10% PV penetration, and 20% PV penetration. With the GridView (ABB, Inc) dispatch model, we used historical load data from 2006 to model electricity production and distribution for each of the three scenarios. Solar PV electric output was estimated using historical weather data from 2006. To bridge the gap between dispatch and air quality modeling, we will create emission profiles for electricity generating units (EGUs) in the Eastern Interconnection from historical Continuous Emissions Monitoring System (CEMS) data. Via those emissions profiles, we will create hourly emission data for EGUs in the Eastern Interconnect for each scenario during 2006. Those data will be incorporated in the Community Multi-scale Air Quality (CMAQ) model using the Sparse Matrix Operator Kernel Emissions (SMOKE) model. Initial results indicate that PV penetration significantly reduces conventional peak electricity production and that, due to reduced emissions during periods of extremely active photochemistry, air quality could see benefits.
Economic Analysis Case Studies of Battery Energy Storage with SAM
DOE Office of Scientific and Technical Information (OSTI.GOV)
DiOrio, Nicholas; Dobos, Aron; Janzou, Steven
2015-11-01
Interest in energy storage has continued to increase as states like California have introduced mandates and subsidies to spur adoption. This energy storage includes customer sited behind-the-meter storage coupled with photovoltaics (PV). This paper presents case study results from California and Tennessee, which were performed to assess the economic benefit of customer-installed systems. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. Themore » analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued. Different dispatch strategies, including manual scheduling and automated peak-shaving were explored to determine ideal ways to use the storage system to increase the system value and mitigate demand charges. Incentives, complex electric tariffs, and site specific load and PV data were used to perform detailed analysis. The analysis was performed using the free, publically available System Advisor Model (SAM) tool. We find that installation of photovoltaics with a lithium-ion battery system priced at $300/kWh in Los Angeles under a high demand charge utility rate structure and dispatched using perfect day-ahead forecasting yields a positive net-present value, while all other scenarios cost the customer more than the savings accrued.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rea, Jonathan E.; Oshman, Christopher J.; Olsen, Michele L.
In this paper, we present performance simulations and techno-economic analysis of a modular dispatchable solar power tower. Using a heliostat field and power block three orders of magnitude smaller than conventional solar power towers, our unique configuration locates thermal storage and a power block directly on a tower receiver. To make the system dispatchable, a valved thermosyphon controls heat flow from a latent heat thermal storage tank to a Stirling engine. The modular design results in minimal balance of system costs and enables high deployment rates with a rapid realization of economies of scale. In this new analysis, we combinemore » performance simulations with techno-economic analysis to evaluate levelized cost of electricity, and find that the system has potential for cost-competitiveness with natural gas peaking plants and alternative dispatchable renewables.« less
49 CFR 228.17 - Dispatcher's record of train movements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Section 228.17 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION, DEPARTMENT OF TRANSPORTATION HOURS OF SERVICE OF RAILROAD EMPLOYEES Records and Reporting § 228..., telephone, radio, or any other electrical or mechanical device to dispatch, report, transmit, receive, or...
Coordinated Scheduling for Interdependent Electric Power and Natural Gas Infrastructures
Zlotnik, Anatoly; Roald, Line; Backhaus, Scott; ...
2016-03-24
The extensive installation of gas-fired power plants in many parts of the world has led electric systems to depend heavily on reliable gas supplies. The use of gas-fired generators for peak load and reserve provision causes high intraday variability in withdrawals from high-pressure gas transmission systems. Such variability can lead to gas price fluctuations and supply disruptions that affect electric generator dispatch, electricity prices, and threaten the security of power systems and gas pipelines. These infrastructures function on vastly different spatio-temporal scales, which prevents current practices for separate operations and market clearing from being coordinated. Here in this article, wemore » apply new techniques for control of dynamic gas flows on pipeline networks to examine day-ahead scheduling of electric generator dispatch and gas compressor operation for different levels of integration, spanning from separate forecasting, and simulation to combined optimal control. We formulate multiple coordination scenarios and develop tractable physically accurate computational implementations. These scenarios are compared using an integrated model of test networks for power and gas systems with 24 nodes and 24 pipes, respectively, which are coupled through gas-fired generators. The analysis quantifies the economic efficiency and security benefits of gas-electric coordination and dynamic gas system operation.« less
Electrical and Chemical Interactions at Mars Workshop. Part 2: Appendix
NASA Technical Reports Server (NTRS)
1992-01-01
The objectives of the workshop were the following: (1) to identify issues related to electrical and chemical interactions between systems and their local environments at Mars; and (2) to recommend means of addressing those issues, including the dispatch of robotic spacecraft to Mars to acquire necessary information. Presentations about Mars' surface and orbital environments, Space Exploration Initiative (SEI) systems, environmental interactions, modeling and analysis, and plans for exploration are presented in viewgraph form.
MIT - Massachusetts Institute of Technology
energy cancer diversity global industry public service Solve The MIT Campaign for a Better World give to produce electricity Drug-carrying nanoparticles could help fight brain cancer Drug-carrying nanoparticles could help fight brain cancer New dispatching approach optimizes a city's taxi fleet New dispatching
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lilliestam, Johan; Barradi, Touria; Caldes, Natalia
Concentrating solar power (CSP) is one of the few renewable electricity technologies that can offer dispatchable electricity at large scale. Thus, it may play an important role in the future, especially to balance fluctuating sources in increasingly renewables-based power systems. Today, its costs are higher than those of PV and wind power and, as most countries do not support CSP, deployment is slow. Unless the expansion gains pace and costs decrease, the industry may stagnate or collapse, and an important technology for climate change mitigation has been lost. Keeping CSP as a maturing technology for dispatchable renewable power thus requiresmore » measures to improve its short-term economic attractiveness and to continue reducing costs in the longer term. We suggest a set of three policy instruments - feed-in tariffs or auctions reflecting the value of dispatchable CSP, and not merely its cost; risk coverage support for innovative designs; and demonstration projects - to be deployed, in regions where CSP has a potentially large role to play. This could provide the CSP industry with a balance of attractive profits and competitive pressure, the incentive to expand CSP while also reducing its costs, making it ready for broad-scale deployment when it is needed.« less
Lilliestam, Johan; Barradi, Touria; Caldes, Natalia; ...
2018-02-16
Concentrating solar power (CSP) is one of the few renewable electricity technologies that can offer dispatchable electricity at large scale. Thus, it may play an important role in the future, especially to balance fluctuating sources in increasingly renewables-based power systems. Today, its costs are higher than those of PV and wind power and, as most countries do not support CSP, deployment is slow. Unless the expansion gains pace and costs decrease, the industry may stagnate or collapse, and an important technology for climate change mitigation has been lost. Keeping CSP as a maturing technology for dispatchable renewable power thus requiresmore » measures to improve its short-term economic attractiveness and to continue reducing costs in the longer term. We suggest a set of three policy instruments - feed-in tariffs or auctions reflecting the value of dispatchable CSP, and not merely its cost; risk coverage support for innovative designs; and demonstration projects - to be deployed, in regions where CSP has a potentially large role to play. This could provide the CSP industry with a balance of attractive profits and competitive pressure, the incentive to expand CSP while also reducing its costs, making it ready for broad-scale deployment when it is needed.« less
NASA Astrophysics Data System (ADS)
Cohen, Stuart M.; Chalmers, Hannah L.; Webber, Michael E.; King, Carey W.
2011-04-01
This work analyses the carbon dioxide (CO2) capture system operation within the Electric Reliability Council of Texas (ERCOT) and Great Britain (GB) electric grids using a previously developed first-order hourly electricity dispatch and pricing model. The grids are compared in their 2006 configuration with the addition of coal-based CO2 capture retrofits and emissions penalties from 0 to 100 US dollars per metric ton of CO2 (USD/tCO2). CO2 capture flexibility is investigated by comparing inflexible CO2 capture systems to flexible ones that can choose between full- and zero-load CO2 capture depending on which operating mode has lower costs or higher profits. Comparing these two grids is interesting because they have similar installed capacity and peak demand, and both are isolated electricity systems with competitive wholesale electricity markets. However, differences in capacity mix, demand patterns, and fuel markets produce diverging behaviours of CO2 capture at coal-fired power plants. Coal-fired facilities are primarily base load in ERCOT for a large range of CO2 prices but are comparably later in the dispatch order in GB and consequently often supply intermediate load. As a result, the ability to capture CO2 is more important for ensuring dispatch of coal-fired facilities in GB than in ERCOT when CO2 prices are high. In GB, higher overall coal prices mean that CO2 prices must be slightly higher than in ERCOT before the emissions savings of CO2 capture offset capture energy costs. However, once CO2 capture is economical, operating CO2 capture on half the coal fleet in each grid achieves greater emissions reductions in GB because the total coal-based capacity is 6 GW greater than in ERCOT. The market characteristics studied suggest greater opportunity for flexible CO2 capture to improve operating profits in ERCOT, but profit improvements can be offset by a flexibility cost penalty.
Apples and oranges: don't compare levelized cost of renewables: Joskow
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2010-12-15
MIT Prof. Paul Joskow points out that the levelized metric is inappropriate for comparing intermittent generating technologies like wind and solar with dispatchable generating technologies like nuclear, gas combined cycle, and coal. The levelized comparison fails to take into account differences in the production profiles of intermittent and dispatchable generating technologies and the associated large variations in the market value of the electricity they supply. When the electricity is produced by an intermittent generating technology, the level of output and the value of the electricity at the times when the output is produced are key variables that should be takenmore » into account.« less
Economically dispatching cogeneration facilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hernandez, E.
Economic dispatching has been used by utilities to meet the energy demands of their customers for decades. The objective was to first load those units which cost the least to run and slowly increase the loading of more expensive units as the incremental energy price increased. Although this concept worked well for utility based systems where incremental costs rose with peak demand, the independent power producers(IPPs) and the power purchase agreements (PPAs) have drastically changed this notion. Most PPAs structured for the IPP environment have negotiated rates which remain the same during peak periods and base their electrical generation onmore » specific process steam requirements. They also must maintain the required production balance of process steam and electrical load in order to qualify as a Public Utility Regulatory Policies Act (PURPA) facility. Consequently, economically dispatching Cogeneration facilities becomes an exercise in adhering to contractual guidelines while operating the equipment in the most efficient manner possible for the given condition. How then is it possible to dispatch a Cogeneration facility that maintains the electrical load demand of JFK Airport while satisfying all of its heating and cooling needs? Contractually, Kennedy International Airport Cogen (KIAC) has specific obligations concerning electrical and thermal energy exported to JFK Airport. The facility`s impressive array of heating and cooling apparatuses together with the newly installed cogen fulfilled the airport`s needs by utilizing an endless combination of new and previously installed equipment. Moreover, in order to economically operate the plant a well structured operating curriculum was necessary.« less
Research on unit commitment with large-scale wind power connected power system
NASA Astrophysics Data System (ADS)
Jiao, Ran; Zhang, Baoqun; Chi, Zhongjun; Gong, Cheng; Ma, Longfei; Yang, Bing
2017-01-01
Large-scale integration of wind power generators into power grid brings severe challenges to power system economic dispatch due to its stochastic volatility. Unit commitment including wind farm is analyzed from the two parts of modeling and solving methods. The structures and characteristics can be summarized after classification has been done according to different objective function and constraints. Finally, the issues to be solved and possible directions of research and development in the future are discussed, which can adapt to the requirements of the electricity market, energy-saving power generation dispatching and smart grid, even providing reference for research and practice of researchers and workers in this field.
Multi-objective optimal dispatch of distributed energy resources
NASA Astrophysics Data System (ADS)
Longe, Ayomide
This thesis is composed of two papers which investigate the optimal dispatch for distributed energy resources. In the first paper, an economic dispatch problem for a community microgrid is studied. In this microgrid, each agent pursues an economic dispatch for its personal resources. In addition, each agent is capable of trading electricity with other agents through a local energy market. In this paper, a simple market structure is introduced as a framework for energy trades in a small community microgrid such as the Solar Village. It was found that both sellers and buyers benefited by participating in this market. In the second paper, Semidefinite Programming (SDP) for convex relaxation of power flow equations is used for optimal active and reactive dispatch for Distributed Energy Resources (DER). Various objective functions including voltage regulation, reduced transmission line power losses, and minimized reactive power charges for a microgrid are introduced. Combinations of these goals are attained by solving a multiobjective optimization for the proposed ORPD problem. Also, both centralized and distributed versions of this optimal dispatch are investigated. It was found that SDP made the optimal dispatch faster and distributed solution allowed for scalability.
Aggregation server for grid-integrated vehicles
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kempton, Willett
2015-05-26
Methods, systems, and apparatus for aggregating electric power flow between an electric grid and electric vehicles are disclosed. An apparatus for aggregating power flow may include a memory and a processor coupled to the memory to receive electric vehicle equipment (EVE) attributes from a plurality of EVEs, aggregate EVE attributes, predict total available capacity based on the EVE attributes, and dispatch at least a portion of the total available capacity to the grid. Power flow may be aggregated by receiving EVE operational parameters from each EVE, aggregating the received EVE operational parameters, predicting total available capacity based on the aggregatedmore » EVE operational parameters, and dispatching at least a portion of the total available capacity to the grid.« less
Dispatchable hydrogen production at the forecourt for electricity grid balancing
NASA Astrophysics Data System (ADS)
Rahil, Abdulla; Gammon, Rupert; Brown, Neil
2017-02-01
The rapid growth of renewable energy (RE) generation and its integration into electricity grids has been motivated by environmental issues and the depletion of fossil fuels. For the same reasons, an alternative to hydrocarbon fuels is needed for vehicles; hence the anticipated uptake of electric and fuel cell vehicles. High penetrations of RE generators with variable and intermittent output threaten to destabilise electricity networks by reducing the ability to balance electricity supply and demand. This can be greatly mitigated by the use of energy storage and demand-side response (DSR) techniques. Hydrogen production by electrolysis is a promising option for providing DSR as well as an emission-free vehicle fuel. Tariff structures can be used to incentivise the operating of electrolysers as controllable (dispatchable) loads. This paper compares the cost of hydrogen production by electrolysis at garage forecourts under both dispatchable and continuous operation, while ensuring no interruption of fuel supply to fuel cell vehicles. An optimisation algorithm is applied to investigate a hydrogen refueling station in both dispatchable and continuous operation. Three scenarios are tested to see whether a reduced off-peak electricity price could lower the cost of electrolytic hydrogen. These scenarios are: 1) "Standard Continuous", where the electrolyser is operated continuously on a standard all-day tariff of 12p/kWh; 2) "Off-peak Only", where it runs only during off-peak periods in a 2-tier tariff system at the lower price of 5p/kWh; and 3) "2-Tier Continuous", operating continuously and paying a low tariff at off- peak times and a high tariff at other times. This study uses the Libyan coastal city of Derna as a case study. The cheapest electricity cost per kg of hydrogen produced was £2.8, which occurred in Scenario 2. The next cheapest, at £5.8 - £6.3, was in Scenario 3, and the most expensive was £6.8/kg in Scenario 1.
NASA Astrophysics Data System (ADS)
Bensaida, K.; Alie, Colin; Elkamel, A.; Almansoori, A.
2017-08-01
This paper presents a novel techno-economic optimization model for assessing the effectiveness of CO2 mitigation options for the electricity generation sub-sector that includes renewable energy generation. The optimization problem was formulated as a MINLP model using the GAMS modeling system. The model seeks the minimization of the power generation costs under CO2 emission constraints by dispatching power from low CO2 emission-intensity units. The model considers the detailed operation of the electricity system to effectively assess the performance of GHG mitigation strategies and integrates load balancing, carbon capture and carbon taxes as methods for reducing CO2 emissions. Two case studies are discussed to analyze the benefits and challenges of the CO2 reduction methods in the electricity system. The proposed mitigations options would not only benefit the environment, but they will as well improve the marginal cost of producing energy which represents an advantage for stakeholders.
NASA Astrophysics Data System (ADS)
Hansson, Linus; Guédez, Rafael; Larchet, Kevin; Laumert, Bjorn
2017-06-01
The dispatchability offered by thermal energy storage (TES) in concentrated solar power (CSP) and solar hybrid plants based on such technology presents the most important difference compared to power generation based only on photovoltaics (PV). This has also been one reason for recent hybridization efforts of the two technologies and the creation of Power Purchase Agreement (PPA) payment schemes based on offering higher payment multiples during daily hours of higher (peak or priority) demand. Recent studies involving plant-level thermal energy storage control strategies are however to a large extent based on pre-determined approaches, thereby not taking into account the actual dynamics of thermal energy storage system operation. In this study, the implementation of a dynamic dispatch strategy in the form of a TRNSYS controller for hybrid PV-CSP plants in the power-plant modelling tool DYESOPT is presented. In doing this it was attempted to gauge the benefits of incorporating a day-ahead approach to dispatch control compared to a fully pre-determined approach determining hourly dispatch only once prior to annual simulation. By implementing a dynamic strategy, it was found possible to enhance technical and economic performance for CSP-only plants designed for peaking operation and featuring low values of the solar multiple. This was achieved by enhancing dispatch control, primarily by taking storage levels at the beginning of every simulation day into account. The sequential prediction of the TES level could therefore be improved, notably for evaluated plants without integrated PV, for which the predicted storage levels deviated less than when PV was present in the design. While also featuring dispatch performance gains, optimal plant configurations for hybrid PV-CSP was found to present a trade-off in economic performance in the form of an increase in break-even electricity price when using the dynamic strategy which was offset to some extent by a reduction in upfront investment cost. An increase in turbine starts for the implemented strategy however highlights that this is where further improvements can be made.
Distributed Energy Resources and Dynamic Microgrid: An Integrated Assessment
NASA Astrophysics Data System (ADS)
Shang, Duo Rick
The overall goal of this thesis is to improve understanding in terms of the benefit of DERs to both utility and to electricity end-users when integrated in power distribution system. To achieve this goal, a series of two studies was conducted to assess the value of DERs when integrated with new power paradigms. First, the arbitrage value of DERs was examined in markets with time-variant electricity pricing rates (e.g., time of use, real time pricing) under a smart grid distribution paradigm. This study uses a stochastic optimization model to estimate the potential profit from electricity price arbitrage over a five-year period. The optimization process involves two types of PHEVs (PHEV-10, and PHEV-40) under three scenarios with different assumptions on technology performance, electricity market and PHEV owner types. The simulation results indicate that expected arbitrage profit is not a viable option to engage PHEVs in dispatching and in providing ancillary services without more favorable policy and PHEV battery technologies. Subsidy or change in electricity tariff or both are needed. Second, it examined the concept of dynamic microgrid as a measure to improve distribution resilience, and estimates the prices of this emerging service. An economic load dispatch (ELD) model is developed to estimate the market-clearing price in a hypothetical community with single bid auction electricity market. The results show that the electricity market clearing price on the dynamic microgrid is predominantly decided by power output and cost of electricity of each type of DGs. At circumstances where CHP is the only source, the electricity market clearing price in the island is even cheaper than the on-grid electricity price at normal times. Integration of PHEVs in the dynamic microgrid will increase electricity market clearing prices. It demonstrates that dynamic microgrid is an economically viable alternative to enhance grid resilience.
Dispatchable Renewable Energy Model for Microgrid Power System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chiou, Fred; Gentle, Jake P.; McJunkin, Timothy R.
2017-04-01
Over the years, many research projects have been performed and focused on finding out the effective ways to balance the power demands and supply on the utility grid. The causes of the imbalance could be the increasing demands from the end users, the loss of power generation (generators down), faults on the transmission lines, power tripped due to overload, and weather conditions, etc. An efficient Load Frequency Control (LFC) can assure the desired electricity quality provided to the residential, commercial and industrial end users. A simulation model is built in this project to investigate the contribution of the modeling ofmore » dispatchable energy such as solar energy, wind power, hydro power and energy storage to the balance of the microgrid power system. An analysis of simplified feedback control system with proportional, integral, and derivative (PID) controller was performed. The purpose of this research is to investigate a simulation model that achieves certain degree of the resilient control for the microgrid.« less
Consumption Behavior Analytics-Aided Energy Forecasting and Dispatch
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Yingchen; Yang, Rui; Jiang, Huaiguang
For decades, electricity customers have been treated as mere recipients of electricity in vertically integrated power systems. However, as customers have widely adopted distributed energy resources and other forms of customer participation in active dispatch (such as demand response) have taken shape, the value of mining knowledge from customer behavior patterns and using it for power system operation is increasing. Further, the variability of renewable energy resources has been considered a liability to the grid. However, electricity consumption has shown the same level of variability and uncertainty, and this is sometimes overlooked. This article investigates data analytics and forecasting methodsmore » to identify correlations between electricity consumption behavior and distributed photovoltaic (PV) output. The forecasting results feed into a predictive energy management system that optimizes energy consumption in the near future to balance customer demand and power system needs.« less
Closeup view of a general electric company demand meter which ...
Close-up view of a general electric company demand meter which formerly monitored railroad power usage obtained from Philadelphia Electric Company sources. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA
Multi-agent simulation of generation expansion in electricity markets.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Botterud, A; Mahalik, M. R.; Veselka, T. D.
2007-06-01
We present a new multi-agent model of generation expansion in electricity markets. The model simulates generation investment decisions of decentralized generating companies (GenCos) interacting in a complex, multidimensional environment. A probabilistic dispatch algorithm calculates prices and profits for new candidate units in different future states of the system. Uncertainties in future load, hydropower conditions, and competitors actions are represented in a scenario tree, and decision analysis is used to identify the optimal expansion decision for each individual GenCo. We test the model using real data for the Korea power system under different assumptions about market design, market concentration, and GenCo'smore » assumed expectations about their competitors investment decisions.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
O'Shaughnessy, Eric; Cutler, Dylan; Ardani, Kristen
As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt modelmore » is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.« less
O'Shaughnessy, Eric; Cutler, Dylan; Ardani, Kristen; ...
2018-01-11
As utility electricity rates evolve, pairing solar photovoltaic (PV) systems with battery storage has potential to ensure the value proposition of residential solar by mitigating economic uncertainty. In addition to batteries, load control technologies can reshape customer load profiles to optimize PV system use. The combination of PV, energy storage, and load control provides an integrated approach to PV deployment, which we call 'solar plus'. The U.S. National Renewable Energy Laboratory's Renewable Energy Optimization (REopt) model is utilized to evaluate cost-optimal technology selection, sizing, and dispatch in residential buildings under a variety of rate structures and locations. The REopt modelmore » is extended to include a controllable or 'smart' domestic hot water heater model and smart air conditioner model. We find that the solar plus approach improves end user economics across a variety of rate structures - especially those that are challenging for PV - including lower grid export rates, non-coincident time-of-use structures, and demand charges.« less
NASA Astrophysics Data System (ADS)
Gao, F.; Song, X. H.; Zhang, Y.; Li, J. F.; Zhao, S. S.; Ma, W. Q.; Jia, Z. Y.
2017-05-01
In order to reduce the adverse effects of uncertainty on optimal dispatch in active distribution network, an optimal dispatch model based on chance-constrained programming is proposed in this paper. In this model, the active and reactive power of DG can be dispatched at the aim of reducing the operating cost. The effect of operation strategy on the cost can be reflected in the objective which contains the cost of network loss, DG curtailment, DG reactive power ancillary service, and power quality compensation. At the same time, the probabilistic constraints can reflect the operation risk degree. Then the optimal dispatch model is simplified as a series of single stage model which can avoid large variable dimension and improve the convergence speed. And the single stage model is solved using a combination of particle swarm optimization (PSO) and point estimate method (PEM). Finally, the proposed optimal dispatch model and method is verified by the IEEE33 test system.
Integrating CO₂ storage with geothermal resources for dispatchable renewable electricity
Buscheck, Thomas A.; Bielicki, Jeffrey M.; Chen, Mingjie; ...
2014-12-31
We present an approach that uses the huge fluid and thermal storage capacity of the subsurface, together with geologic CO₂ storage, to harvest, store, and dispatch energy from subsurface (geothermal) and surface (solar, nuclear, fossil) thermal resources, as well as energy from electrical grids. Captured CO₂ is injected into saline aquifers to store pressure, generate artesian flow of brine, and provide an additional working fluid for efficient heat extraction and power conversion. Concentric rings of injection and production wells are used to create a hydraulic divide to store pressure, CO₂, and thermal energy. Such storage can take excess power frommore » the grid and excess/waste thermal energy, and dispatch that energy when it is demanded, enabling increased penetration of variable renewables. Stored CO₂ functions as a cushion gas to provide enormous pressure-storage capacity and displaces large quantities of brine, which can be desalinated and/or treated for a variety of beneficial uses.« less
Analysis of Modeling Assumptions used in Production Cost Models for Renewable Integration Studies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stoll, Brady; Brinkman, Gregory; Townsend, Aaron
2016-01-01
Renewable energy integration studies have been published for many different regions exploring the question of how higher penetration of renewable energy will impact the electric grid. These studies each make assumptions about the systems they are analyzing; however the effect of many of these assumptions has not been yet been examined and published. In this paper we analyze the impact of modeling assumptions in renewable integration studies, including the optimization method used (linear or mixed-integer programming) and the temporal resolution of the dispatch stage (hourly or sub-hourly). We analyze each of these assumptions on a large and a small systemmore » and determine the impact of each assumption on key metrics including the total production cost, curtailment of renewables, CO2 emissions, and generator starts and ramps. Additionally, we identified the impact on these metrics if a four-hour ahead commitment step is included before the dispatch step and the impact of retiring generators to reduce the degree to which the system is overbuilt. We find that the largest effect of these assumptions is at the unit level on starts and ramps, particularly for the temporal resolution, and saw a smaller impact at the aggregate level on system costs and emissions. For each fossil fuel generator type we measured the average capacity started, average run-time per start, and average number of ramps. Linear programming results saw up to a 20% difference in number of starts and average run time of traditional generators, and up to a 4% difference in the number of ramps, when compared to mixed-integer programming. Utilizing hourly dispatch instead of sub-hourly dispatch saw no difference in coal or gas CC units for either start metric, while gas CT units had a 5% increase in the number of starts and 2% increase in the average on-time per start. The number of ramps decreased up to 44%. The smallest effect seen was on the CO2 emissions and total production cost, with a 0.8% and 0.9% reduction respectively when using linear programming compared to mixed-integer programming and 0.07% and 0.6% reduction, respectively, in the hourly dispatch compared to sub-hourly dispatch.« less
Modeling and Simulation of Bus Dispatching Policy for Timed Transfers on Signalized Networks
NASA Astrophysics Data System (ADS)
Cho, Hsun-Jung; Lin, Guey-Shii
2007-12-01
The major work of this study is to formulate the system cost functions and to integrate the bus dispatching policy with signal control. The integrated model mainly includes the flow dispersion model for links, signal control model for nodes, and dispatching control model for transfer terminals. All such models are inter-related for transfer operations in one-center transit network. The integrated model that combines dispatching policies with flexible signal control modes can be applied to assess the effectiveness of transfer operations. It is found that, if bus arrival information is reliable, an early dispatching decision made at the mean bus arrival times is preferable. The costs for coordinated operations with slack times are relatively low at the optimal common headway when applying adaptive route control. Based on such findings, a threshold function of bus headway for justifying an adaptive signal route control under various time values of auto drivers is developed.
Review and future perspective of central receiver design and performance
NASA Astrophysics Data System (ADS)
Zhu, Guangdong; Libby, Cara
2017-06-01
Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middle East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600°C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700°C-800°C—and even above 1000°C—so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.
Review and Future Perspective of Central Receiver Design and Performance
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhu, Guangdong; Libby, Cara
Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middlemore » East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600 degrees C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700 degrees C-800 degrees C -- and even above 1000 degrees C -- so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.« less
NASA Astrophysics Data System (ADS)
Bay, Christopher Joseph
Massachusetts' Act to Promote Energy Diversity requires distribution companies to solicit contracts for up to 1600 MW of offshore wind. To test whether offshore wind projects can meet the Act's requirement to reduce C02 emissions, the Oak Ridge Competitive Electricity Dispatch Model was used to forecast changes in ISO New England's resource mix under five different wind capacity levels and calculate avoided C02 emissions attributable to offshore wind. With 1600 MW of installed capacity, representing full solicitation under the Act, reliance on natural gas is reduced by ˜10% and carbon emissions decline by ˜9%. This represents significant progress towards the goals of the Global Warming Solutions Act and the Clean Power Plan. The 5000 MW scenario reduces emissions enough to meet the Clean Power Plan's 2030 goals. This study's application of a dispatch model provides an example for policymakers of a simple and cost-effective approach for assessing a project's value.
Economic Operation of Supercritical CO2 Refrigeration Energy Storage Technology
NASA Astrophysics Data System (ADS)
Hay, Ryan
With increasing penetration of intermittent renewable energy resources, improved methods of energy storage are becoming a crucial stepping stone in the path toward a smarter, greener grid. SuperCritical Technologies is a company based in Bremerton, WA that is developing a storage technology that can operate entirely on waste heat, a resource that is otherwise dispelled into the environment. The following research models this storage technology in several electricity spot markets around the US to determine if it is economically viable. A modification to the storage dispatch scheme is then presented which allows the storage unit to increase its profit in real-time markets by taking advantage of extreme price fluctuations. Next, the technology is modeled in combination with an industrial load profile on two different utility rate schedules to determine potential cost savings. The forecast of facility load has a significant impact on savings from the storage dispatch, so an exploration into this relationship is then presented.
Power management of remote microgrids considering battery lifetime
NASA Astrophysics Data System (ADS)
Chalise, Santosh
Currently, 20% (1.3 billion) of the world's population still lacks access to electricity and many live in remote areas where connection to the grid is not economical or practical. Remote microgrids could be the solution to the problem because they are designed to provide power for small communities within clearly defined electrical boundaries. Reducing the cost of electricity for remote microgrids can help to increase access to electricity for populations in remote areas and developing countries. The integration of renewable energy and batteries in diesel based microgrids has shown to be effective in reducing fuel consumption. However, the operational cost remains high due to the low lifetime of batteries, which are heavily used to improve the system's efficiency. In microgrid operation, a battery can act as a source to augment the generator or a load to ensure full load operation. In addition, a battery increases the utilization of PV by storing extra energy. However, the battery has a limited energy throughput. Therefore, it is required to provide balance between fuel consumption and battery lifetime throughput in order to lower the cost of operation. This work presents a two-layer power management system for remote microgrids. First layer is day ahead scheduling, where power set points of dispatchable resources were calculated. Second layer is real time dispatch, where schedule set points from the first layer are accepted and resources are dispatched accordingly. A novel scheduling algorithm is proposed for a dispatch layer, which considers the battery lifetime in optimization and is expected to reduce the operational cost of the microgrid. This method is based on a goal programming approach which has the fuel and the battery wear cost as two objectives to achieve. The effectiveness of this method was evaluated through a simulation study of a PV-diesel hybrid microgrid using deterministic and stochastic approach of optimization.
NASA Astrophysics Data System (ADS)
Sohnen, Julia Meagher
This thesis explores the implications of the increased adoption of plug-in electric vehicles in California through its effect on the operation of the state's electric grid. The well-to-wheels emissions associated with driving an electric vehicle depend on the resource mix of the electricity grid used to charge the battery. We present a new least-cost dispatch model, EDGE-NET, for the California electricity grid consisting of interconnected sub-regions that encompass the six largest state utilities that can be used to evaluate the impact of growing electric vehicle demand on existing power grid infrastructure system and energy resources. This model considers spatiality and temporal dynamics of energy demand and supply when determining the regional impacts of additional charging profiles on the current electricity network. Model simulation runs for one year show generation and transmission congestion to be reasonable similar to historical data. Model simulation results show that average emissions and system costs associated with electricity generation vary significantly by time of day, season, and location. Marginal cost and emissions also exhibit seasonal and diurnal differences, but show less spatial variation. Sensitivity of demand analysis shows that the relative changes to average emissions and system costs respond asymmetrically to increases and decreases in electricity demand. These results depend on grid mix at the time and the marginal power plant type. In minimizing total system cost, the model will choose to dispatch the lowest-cost resource to meet additional vehicle demand, regardless of location, as long as transmission capacity is available. Location of electric vehicle charging has a small effect on the marginal greenhouse gas emissions associated with additional generation, due to electricity losses in the transmission grid. We use a geographically explicit, charging assessment model for California to develop and compare the effects of two charging profiles. Comparison of these two basic scenarios points to savings in greenhouse gas emissions savings and operational costs from delayed charging of electric vehicles. Vehicle charging simulations confirm that plug-in electric vehicles alone are unlikely to require additional generation or transmission infrastructure. EDGE-NET was successfully benchmarked against historical data for the present grid but additional work is required to expand the model for future scenario evaluation. We discuss how the model might be adapted for high penetrations of variable renewable energy resources, and the use of grid storage. Renewable resources such as wind and solar vary in California vary significantly by time-of-day, season, and location. However, combination of multiple resources from different geographic regions through transmission grid interconnection is expected to help mitigate the impacts of variability. EDGE-NET can evaluate interaction of supply and demand through the existing transmission infrastructure and can identify any critical network bottlenecks or areas for expansion. For this reason, EDGE-NET will be an important tool to evaluate energy policy scenarios.
NASA Astrophysics Data System (ADS)
Glatzmaier, G. C.; Rea, J.; Olsen, M. L.; Oshman, C.; Hardin, C.; Alleman, J.; Sharp, J.; Weigand, R.; Campo, D.; Hoeschele, G.; Parilla, P. A.; Siegel, N. P.; Toberer, E. S.; Ginley, D. S.
2017-06-01
We are developing a novel concentrating solar electricity-generating technology that is both modular and dispatchable. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) uses concentrated solar flux to generate high-temperature thermal energy, which directly converts to electricity via thermoelectric generators (TEGs), stored within a phase-change material (PCM) for electricity generation at a later time, or both allowing for simultaneous charging of the PCM and electricity generation. STEALS has inherent features that drive its cost-competitive scale to be much smaller than current commercial concentrating solar power (CSP) plants. Most obvious is modularity of the solid-state TEG, which favors smaller scales in the kilowatt range as compared to CSP steam turbines, which are minimally 50 MWe for commercial power plants. Here, we present techno-economic and market analyses that show STEALS can be a cost-effective electricity-generating technology with particular appeal to small-scale microgrid applications. We evaluated levelized cost of energy (LCOE) for STEALS and for a comparable photovoltaic (PV) system with battery storage. For STEALS, we estimated capital costs and the LCOE as functions of the type of PCM including the use of recycled aluminum alloys, and evaluated the cost tradeoffs between plasma spray coatings and solution-based boron coatings that are applied to the wetted surfaces of the PCM subsystem. We developed a probabilistic cost model that accounts for uncertainties in the cost and performance inputs to the LCOE estimation. Our probabilistic model estimated LCOE for a 100-kWe STEALS system that had 5 hours of thermal storage and 8-10 hours of total daily power generation. For these cases, the solar multiple for the heliostat field varied between 1.12 and 1.5. We identified microgrids as a likely market for the STEALS system. We characterized microgrid markets in terms of nominal power, dispatchability, geographic location, and customer type, and specified additional features for STEALS that are needed to meet the needs of this growing power market.
Robust optimization based energy dispatch in smart grids considering demand uncertainty
NASA Astrophysics Data System (ADS)
Nassourou, M.; Puig, V.; Blesa, J.
2017-01-01
In this study we discuss the application of robust optimization to the problem of economic energy dispatch in smart grids. Robust optimization based MPC strategies for tackling uncertain load demands are developed. Unexpected additive disturbances are modelled by defining an affine dependence between the control inputs and the uncertain load demands. The developed strategies were applied to a hybrid power system connected to an electrical power grid. Furthermore, to demonstrate the superiority of the standard Economic MPC over the MPC tracking, a comparison (e.g average daily cost) between the standard MPC tracking, the standard Economic MPC, and the integration of both in one-layer and two-layer approaches was carried out. The goal of this research is to design a controller based on Economic MPC strategies, that tackles uncertainties, in order to minimise economic costs and guarantee service reliability of the system.
2017-01-01
Load information plays an important role in deregulated electricity markets, since it is the primary factor to make critical decisions on production planning, day-to-day operations, unit commitment and economic dispatch. Being able to predict the load for a short term, which covers one hour to a few days, equips power generation facilities and traders with an advantage. With the deregulation of electricity markets, a variety of short term load forecasting models are developed. Deregulation in Turkish Electricity Market has started in 2001 and liberalization is still in progress with rules being effective in its predefined schedule. However, there is a very limited number of studies for Turkish Market. In this study, we introduce two different models for current Turkish Market using Seasonal Autoregressive Integrated Moving Average (SARIMA) and Artificial Neural Network (ANN) and present their comparative performances. Building models that cope with the dynamic nature of deregulated market and are able to run in real-time is the main contribution of this study. We also use our ANN based model to evaluate the effect of several factors, which are claimed to have effect on electrical load. PMID:28426739
Bozkurt, Ömer Özgür; Biricik, Göksel; Tayşi, Ziya Cihan
2017-01-01
Load information plays an important role in deregulated electricity markets, since it is the primary factor to make critical decisions on production planning, day-to-day operations, unit commitment and economic dispatch. Being able to predict the load for a short term, which covers one hour to a few days, equips power generation facilities and traders with an advantage. With the deregulation of electricity markets, a variety of short term load forecasting models are developed. Deregulation in Turkish Electricity Market has started in 2001 and liberalization is still in progress with rules being effective in its predefined schedule. However, there is a very limited number of studies for Turkish Market. In this study, we introduce two different models for current Turkish Market using Seasonal Autoregressive Integrated Moving Average (SARIMA) and Artificial Neural Network (ANN) and present their comparative performances. Building models that cope with the dynamic nature of deregulated market and are able to run in real-time is the main contribution of this study. We also use our ANN based model to evaluate the effect of several factors, which are claimed to have effect on electrical load.
Multi-objective generation scheduling with hybrid energy resources
NASA Astrophysics Data System (ADS)
Trivedi, Manas
In economic dispatch (ED) of electric power generation, the committed generating units are scheduled to meet the load demand at minimum operating cost with satisfying all unit and system equality and inequality constraints. Generation of electricity from the fossil fuel releases several contaminants into the atmosphere. So the economic dispatch objective can no longer be considered alone due to the environmental concerns that arise from the emissions produced by fossil fueled electric power plants. This research is proposing the concept of environmental/economic generation scheduling with traditional and renewable energy sources. Environmental/economic dispatch (EED) is a multi-objective problem with conflicting objectives since emission minimization is conflicting with fuel cost minimization. Production and consumption of fossil fuel and nuclear energy are closely related to environmental degradation. This causes negative effects to human health and the quality of life. Depletion of the fossil fuel resources will also be challenging for the presently employed energy systems to cope with future energy requirements. On the other hand, renewable energy sources such as hydro and wind are abundant, inexhaustible and widely available. These sources use native resources and have the capacity to meet the present and the future energy demands of the world with almost nil emissions of air pollutants and greenhouse gases. The costs of fossil fuel and renewable energy are also heading in opposite directions. The economic policies needed to support the widespread and sustainable markets for renewable energy sources are rapidly evolving. The contribution of this research centers on solving the economic dispatch problem of a system with hybrid energy resources under environmental restrictions. It suggests an effective solution of renewable energy to the existing fossil fueled and nuclear electric utilities for the cheaper and cleaner production of electricity with hourly emission targets. Since minimizing the emissions and fuel cost are conflicting objectives, a practical approach based on multi-objective optimization is applied to obtain compromised solutions in a single simulation run using genetic algorithm. These solutions are known as non-inferior or Pareto-optimal solutions, graphically illustrated by the trade-off curves between criterions fuel cost and pollutant emission. The efficacy of the proposed approach is illustrated with the help of different sample test cases. This research would be useful for society, electric utilities, consultants, regulatory bodies, policy makers and planners.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The Electricity Market Module (EMM) is the electricity supply component of the National Energy Modeling System (NEMS). The EMM represents the generation, transmission, and pricing of electricity. It consists of four submodules: the Electricity Capacity Planning (ECP) Submodule, the Electricity Fuel Dispatch (EFD) Submodule, the Electricity Finance and Pricing (EFP) Submodule, and the Load and Demand-Side Management (LDSM) Submodule. For the Annual Energy Outlook 1998 (AEO98), the EMM has been modified to represent Renewable Portfolio Standards (RPS), which are included in many of the Federal and state proposals for deregulating the electric power industry. A RPS specifies that electricity suppliersmore » must produce a minimum level of generation using renewable technologies. Producers with insufficient renewable generating capacity can either build new plants or purchase {open_quotes}credits{close_quotes} from other suppliers with excess renewable generation. The representation of a RPS involves revisions to the ECP, EFD, and the EFP. The ECP projects capacity additions required to meet the minimum renewable generation levels in future years. The EFD determines the sales and purchases of renewable credits for the current year. The EFP incorporates the cost of building capacity and trading credits into the price of electricity.« less
NASA Astrophysics Data System (ADS)
Flores, Robert Joseph
Growing concerns over greenhouse gas and pollutant emissions have increased the pressure to shift energy conversion paradigms from current forms to more sustainable methods, such as through the use of distributed energy resources (DER) at industrial and commercial buildings. This dissertation is concerned with the optimal design and dispatch of a DER system installed at an industrial or commercial building. An optimization model that accurately captures typical utility costs and the physical constraints of a combined cooling, heating, and power (CCHP) system is designed to size and operate a DER system at a building. The optimization model is then used with cooperative game theory to evaluate the financial performance of a CCHP investment. The CCHP model is then modified to include energy storage, solar powered generators, alternative fuel sources, carbon emission limits, and building interactions with public and fleet PEVs. Then, a separate plugin electric vehicle (PEV) refueling model is developed to determine the cost to operate a public Level 3 fast charging station. The CCHP design and dispatch results show the size of the building load and consistency of the thermal loads are critical to positive financial performance. While using the CCHP system to produce cooling can provide savings, heat production drives positive financial performance. When designing the DER system to reduce carbon emissions, the use of renewable fuels can allow for a gas turbine system with heat recovery to reduce carbon emissions for a large university by 67%. Further reductions require large photovoltaic installations coupled with energy storage or the ability to export electricity back to the grid if costs are to remain relatively low. When considering Level 3 fast charging equipment, demand charges at low PEV travel levels are sufficiently high to discourage adoption. Integration of the equipment can reduce demand charge costs only if the building maximum demand does not coincide with PEV refueling. Electric vehicle refueling does not typically affect DER design at low PEV travel levels, but can as electric vehicle travel increases. However, as PEV travel increases, the stochastic nature of PEV refueling disappears, and the optimization problem may become deterministic.
Modeling work of the dispatching service of high-rise building as queuing system
NASA Astrophysics Data System (ADS)
Dement'eva, Marina; Dement'eva, Anastasiya
2018-03-01
The article presents the results of calculating the performance indicators of the dispatcher service of a high-rise building as a queuing system with an unlimited queue. The calculation was carried out for three models: with a single control room and brigade of service, with a single control room and a specialized service, with several dispatch centers and specialized services. The aim of the work was to investigate the influence of the structural scheme of the organization of the dispatcher service of a high-rise building on the amount of operating costs and the time of processing and fulfilling applications. The problems of high-rise construction and their impact on the complication of exploitation are analyzed. The composition of exploitation activities of high-rise buildings is analyzed. The relevance of the study is justified by the need to review the role of dispatch services in the structure of management of the quality of buildings. Dispatching service from the lower level of management of individual engineering systems becomes the main link in the centralized automated management of the exploitation of high-rise buildings. With the transition to market relations, the criterion of profitability at the organization of the dispatching service becomes one of the main parameters of the effectiveness of its work. A mathematical model for assessing the efficiency of the dispatching service on a set of quality of service indicators is proposed. The structure of operating costs is presented. The algorithm of decision-making is given when choosing the optimal structural scheme of the dispatching service of a high-rise building.
NASA Astrophysics Data System (ADS)
Fradi, Aniss
The ability to allocate the active power (MW) loading on transmission lines and transformers, is the basis of the "flow based" transmission allocation system developed by the North American Electric Reliability Council. In such a system, the active power flows must be allocated to each line or transformer in proportion to the active power being transmitted by each transaction imposed on the system. Currently, this is accomplished through the use of the linear Power Transfer Distribution Factors (PTDFs). Unfortunately, no linear allocation models exist for other energy transmission quantities, such as MW and MVAR losses, MVAR and MVA flows, etc. Early allocation schemes were developed to allocate MW losses due to transactions to branches in a transmission system, however they exhibited diminished accuracy, since most of them are based on linear power flow modeling of the transmission system. This thesis presents a new methodology to calculate Energy Transaction Allocation factors (ETA factors, or eta factors), using the well-known process of integration of a first derivative function, as well as consistent and well-established mathematical and AC power flow models. The factors give a highly accurate allocation of any non-linear system quantity to transactions placed on the transmission system. The thesis also extends the new ETA factors calculation procedure to restructure a new economic dispatch scheme where multiple sets of generators are economically dispatched to meet their corresponding load and their share of the losses.
View west of load dispatch model board; section covers substations ...
View west of load dispatch model board; section covers substations from edgerly (right) to thorndale and west yard (left). Instruments at bottom of center board section formerly monitored energy usage and were replaced by a computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA
HOMER: The hybrid optimization model for electric renewable
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lilienthal, P.; Flowers, L.; Rossmann, C.
1995-12-31
Hybrid renewable systems are often more cost-effective than grid extensions or isolated diesel generators for providing power to remote villages. There are a wide variety of hybrid systems being developed for village applications that have differing combinations of wind, photovoltaics, batteries, and diesel generators. Due to variations in loads and resources determining the most appropriate combination of these components for a particular village is a difficult modelling task. To address this design problem the National Renewable Energy Laboratory has developed the Hybrid Optimization Model for Electric Renewables (HOMER). Existing models are either too detailed for screening analysis or too simplemore » for reliable estimation of performance. HOMER is a design optimization model that determines the configuration, dispatch, and load management strategy that minimizes life-cycle costs for a particular site and application. This paper describes the HOMER methodology and presents representative results.« less
Hybrid solar converters for maximum exergy and inexpensive dispatchable electricity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Branz, Howard M.; Regan, William; Gerst, Kacy J.
Photovoltaic (PV) solar energy systems are being deployed at an accelerating rate to supply low-carbon electricity worldwide. However, PV is unlikely to economically supply much more than 10% of the world's electricity unless there is a dramatic reduction in the cost of electricity storage. There is an important scientific and technological opportunity to address the storage challenge by developing inexpensive hybrid solar converters that collect solar heat at temperatures between about 200 and 600 °C and also incorporate PV. Since heat can be stored and converted to electricity at relatively low cost, collection of high exergy content (high temperature) solarmore » heat can provide energy that is dispatchable on demand to meet loads that are not well matched to solar insolation. However, PV cells can collect and convert much of the solar spectrum to electricity more efficiently and inexpensively than solar thermal systems. Advances in spectrum-splitting optics, high-temperature PV cells, thermal management and system design are needed for transformational hybrid converters. We propose that maximizing the exergy output from the solar converters while minimizing the cost of exergy can help propel solar energy toward a higher contribution to carbon-free electricity in the long term than the prevailing paradigm of maximizing the energy output while minimizing the cost of energy« less
Electricity Storage and the Hydrogen-Chlorine Fuel Cell
NASA Astrophysics Data System (ADS)
Rugolo, Jason Steven
Electricity storage is an essential component of the transforming energy marketplace. Its absence at any significant scale requires that electricity producers sit ready to respond to every flick of a switch, constantly adjusting power production to meet demand. The dispatchable electricity production technologies that currently enable this type of market are growing unpopular because of their carbon emissions. Popular methods to move away from fossil fuels are wind and solar power. These sources also happen to be the least dispatchable. Electricity storage can solve that problem. By overproducing during sunlight to store energy for evening use, or storing during windy periods for delivery in future calm ones, electricity storage has the potential to allow intermittent renewable sources to constitute a large portion of our electricity mix. I investigate the variability of wind in Chapter 2, and show that the variability is not significantly reduced by geographically distributing power production over the entire country of the Netherlands. In Chapter 3, I calculate the required characteristics of a linear-response, constant activity storage technology to map wind and solar production scenarios onto several different supply scenarios for a range of specified system efficiencies. I show that solid electrode batteries have two orders of magnitude too little energy per unit power to be well suited for renewable balancing and emphasize the value of the modular separation between the power and energy components of regenerative fuel cell technologies. In Chapter 4 I introduce the regenerative hydrogen-chlorine fuel cell (rHCFC), which is a specific technology that shows promise for the above applications. In collaboration with Sustainable Innovations, we have made and tested 6 different rHCFCs. In order to understand the relative importance of the different inefficiencies in the rHCFC, Chapter 5 introduces a complex temperature and concentration dependent model of the rHCFC cell potential versus current density. The model identifies the chlorine electrode overpotential as the most important loss for high efficiency operation. In Chapter 6 I develop improved materials for the chlorine electrode and report the discovery of promising conducting metal oxide alloy electrodes, which display high catalytic activity with a small precious metal content.
The effect of work shift configurations on emergency medical dispatch center response.
Montassier, Emmanuel; Labady, Julien; Andre, Antoine; Potel, Gilles; Berthier, Frederic; Jenvrin, Joel; Penverne, Yann
2015-01-01
It has been proved that emergency medical dispatch centers (EMDC) save lives by promoting an appropriate allocation of emergency medical service resources. Indeed, optimal dispatcher call duration is pivotal to reduce the time gap between the time a call is placed and the delivery of medical care. However, little is known about the impact of work shift configurations (i.e., work shift duration and work shift rotation throughout the day) and dispatcher call duration. Thus, the objective of our study was to assess the effect of work shift configurations on dispatcher call duration. During a 1-year study period, we analyzed the dispatcher call durations for medical and trauma calls during the 4 different work shift rotations (day, morning, evening, and night) and during the 10-hour work shift of each dispatcher in the EMDC of Nantes. We extracted dispatcher call durations from our advanced telephone system, configured with CC Pulse + (Genesys, Alcatel Lucent), and collected them in a custom designed database (Excel, Microsoft). Afterward, we analyzed these data using linear mixed effects models. During the study period, our EMDC received 408,077 calls. Globally, the mean dispatcher call duration was 107 ± 45 seconds. Based on multivariate linear mixed effects models, the dispatcher call duration was affected by night work shift and work shift duration greater than 8 hours, increasing it by about 10 ± 1 seconds and 4 ± 1 seconds, respectively (both p < 0.001). Our study showed that there was a statistically significant difference in dispatcher call duration over work shift rotation and duration, with longer durations seen over night shifts and shifts over 8 hours. While these differences are small and may not have clinical significance, they may have implications for EMDC efficiency.
View west within the periphery of the load dispatch model ...
View west within the periphery of the load dispatch model board, operator's console is at lower center and button board is at lower right of the photograph; section of model board shown covers substation from Perryman (left) to Frankford (right); instruments at right center of photograph formerly monitored energy usage and were replaced by computerized monitoring system. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA
Research on Novel Algorithms for Smart Grid Reliability Assessment and Economic Dispatch
NASA Astrophysics Data System (ADS)
Luo, Wenjin
In this dissertation, several studies of electric power system reliability and economy assessment methods are presented. To be more precise, several algorithms in evaluating power system reliability and economy are studied. Furthermore, two novel algorithms are applied to this field and their simulation results are compared with conventional results. As the electrical power system develops towards extra high voltage, remote distance, large capacity and regional networking, the application of a number of new technique equipments and the electric market system have be gradually established, and the results caused by power cut has become more and more serious. The electrical power system needs the highest possible reliability due to its complication and security. In this dissertation the Boolean logic Driven Markov Process (BDMP) method is studied and applied to evaluate power system reliability. This approach has several benefits. It allows complex dynamic models to be defined, while maintaining its easy readability as conventional methods. This method has been applied to evaluate IEEE reliability test system. The simulation results obtained are close to IEEE experimental data which means that it could be used for future study of the system reliability. Besides reliability, modern power system is expected to be more economic. This dissertation presents a novel evolutionary algorithm named as quantum evolutionary membrane algorithm (QEPS), which combines the concept and theory of quantum-inspired evolutionary algorithm and membrane computation, to solve the economic dispatch problem in renewable power system with on land and offshore wind farms. The case derived from real data is used for simulation tests. Another conventional evolutionary algorithm is also used to solve the same problem for comparison. The experimental results show that the proposed method is quick and accurate to obtain the optimal solution which is the minimum cost for electricity supplied by wind farm system.
Impacts of temperature change on ambulance dispatches and seasonal effect modification.
Cheng, Jian; Xu, Zhiwei; Zhao, Desheng; Xie, Mingyu; Yang, Huihui; Wen, Liying; Li, Kesheng; Su, Hong
2016-12-01
Ambulance dispatch is a proxy of acute health outcomes, and growing epidemiological evidence documented its relation to extreme temperature events. Research, however, on short-term temperature change and ambulance dispatches is scarce. We aimed to investigate the effect of short-term temperature change on ambulance dispatches and potential modification by season. Daily data on ambulance dispatch and weather factors were collected in Huainan, a Chinese inland city from December 2011 through December 2013. A Poison generalized linear regression model combined with distributed lag nonlinear model was constructed to examine the association of temperature change between neighboring days (TCN) with ambulance dispatches. The effect modification by season was also examined. There were 48,700 ambulance attendances during the study period. A statistically significant association of TCN with ambulance dispatches was observed. Temperature rise between neighboring days (TCN > 0) was associated with elevated adverse risk of ambulance dispatches, and the effects appeared to be acute (lag0, on the current day) and could last for at least a week, while temperature drop between neighboring days (TCN < 0) had a protective effect. For a 1 °C increase of TCN at lag0 and lag06 (on the 7-day moving average), the risk of ambulance dispatches increased by 2 % (95 % CI 1-3 %) and 7 (95 % CI 1-13 %), respectively. Extreme TCN increase (95th percentile, 3.3 °C vs. 0 °C) at lag0 and lag05 was accompanied by 6 (95 % CI 3-8 %) and 27 % (95 % CI 12-44 %) increase in ambulance dispatches. Ambulance dispatches were more vulnerable to extremely great temperature rise in summer and autumn. TCN was adopted for the first time to quantify the impact of short-term temperature change on ambulance dispatches. Temperature drop between neighboring days (TCN < 0) had a protective effect on ambulance dispatches, while temperature rise between neighboring days (TCN > 0) could acutely trigger the increase in ambulance dispatches, and TCN effect differs by season.
Wang, Tiancai; He, Xing; Huang, Tingwen; Li, Chuandong; Zhang, Wei
2017-09-01
The economic emission dispatch (EED) problem aims to control generation cost and reduce the impact of waste gas on the environment. It has multiple constraints and nonconvex objectives. To solve it, the collective neurodynamic optimization (CNO) method, which combines heuristic approach and projection neural network (PNN), is attempted to optimize scheduling of an electrical microgrid with ten thermal generators and minimize the plus of generation and emission cost. As the objective function has non-derivative points considering valve point effect (VPE), differential inclusion approach is employed in the PNN model introduced to deal with them. Under certain conditions, the local optimality and convergence of the dynamic model for the optimization problem is analyzed. The capability of the algorithm is verified in a complicated situation, where transmission loss and prohibited operating zones are considered. In addition, the dynamic variation of load power at demand side is considered and the optimal scheduling of generators within 24 h is described. Copyright © 2017 Elsevier Ltd. All rights reserved.
Insuring wind energy production
NASA Astrophysics Data System (ADS)
D'Amico, Guglielmo; Petroni, Filippo; Prattico, Flavio
2017-02-01
This paper presents an insurance contract that the supplier of wind energy may subscribe in order to immunize the production of electricity against the volatility of the wind speed process. The other party of the contract may be any dispatchable energy producer, like gas turbine or hydroelectric generator, which can supply the required energy in case of little or no wind. The adoption of a stochastic wind speed model allows the computation of the fair premium that the wind power supplier has to pay in order to hedge the risk of inadequate output of electricity at any time. Recursive type equations are obtained for the prospective mathematical reserves of the insurance contract and for their higher order moments. The model and the validity of the results are illustrated through a numerical example.
An Overview of the Automated Dispatch Controller Algorithms in the System Advisor Model (SAM)
DOE Office of Scientific and Technical Information (OSTI.GOV)
DiOrio, Nicholas A
2017-11-22
Three automatic dispatch modes have been added to the battery model within the System Adviser Model. These controllers have been developed to perform peak shaving in an automated fashion, providing users with a way to see the benefit of reduced demand charges without manually programming a complicated dispatch control. A flexible input option allows more advanced interaction with the automated controller. This document will describe the algorithms in detail and present brief results on its use and limitations.
Ancillary-service costs for 12 US electric utilities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, B.; Hirst, E.
1996-03-01
Ancillary services are those functions performed by electrical generating, transmission, system-control, and distribution-system equipment and people to support the basic services of generating capacity, energy supply, and power delivery. The Federal Energy Regulatory Commission defined ancillary services as ``those services necessary to support the transmission of electric power from seller to purchaser given the obligations of control areas and transmitting utilities within those control areas to maintain reliable operations of the interconnected transmission system.`` FERC divided these services into three categories: ``actions taken to effect the transaction (such as scheduling and dispatching services) , services that are necessary to maintainmore » the integrity of the transmission system [and] services needed to correct for the effects associated with undertaking a transaction.`` In March 1995, FERC published a proposed rule to ensure open and comparable access to transmission networks throughout the country. The rule defined six ancillary services and developed pro forma tariffs for these services: scheduling and dispatch, load following, system protection, energy imbalance, loss compensation, and reactive power/voltage control.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M; Palchak, Joseph D; Ehlen, Annaliese K
This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plantsmore » for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M; Palchak, Joseph D; Ehlen, Annaliese K
This chapter on Tamil Nadu is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plantsmore » for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M; Palchak, Joseph D; Ehlen, Annaliese K
This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plantsmore » for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M; Palchak, Joseph D; Ehlen, Annaliese K
This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plantsmore » for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M; Palchak, Joseph D; Ehlen, Annaliese K
This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plantsmore » for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M; Palchak, Joseph D; Ehlen, Annaliese K
This chapter on Andhra Pradesh is one of six state chapters included in Appendix C of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study). The objective of the state chapters is to provide modeling assumptions, results, and next steps to use and improve the model specific to each state. The model has inherent uncertainties, particularly in how the intrastate transmission network and RE generation projects will develop (e.g., locations, capacities). The model also does not include information on contracts or must-run status of particular plantsmore » for reliability purposes. By providing details on the higher spatial resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.'« less
NASA Astrophysics Data System (ADS)
Ahangaran, Daryoush Kaveh; Yasrebi, Amir Bijan; Wetherelt, Andy; Foster, Patrick
2012-10-01
Application of fully automated systems for truck dispatching plays a major role in decreasing the transportation costs which often represent the majority of costs spent on open pit mining. Consequently, the application of a truck dispatching system has become fundamentally important in most of the world's open pit mines. Recent experiences indicate that by decreasing a truck's travelling time and the associated waiting time of its associated shovel then due to the application of a truck dispatching system the rate of production will be considerably improved. Computer-based truck dispatching systems using algorithms, advanced and accurate software are examples of these innovations. Developing an algorithm of a computer- based program appropriated to a specific mine's conditions is considered as one of the most important activities in connection with computer-based dispatching in open pit mines. In this paper the changing trend of programming and dispatching control algorithms and automation conditions will be discussed. Furthermore, since the transportation fleet of most mines use trucks with different capacities, innovative methods, operational optimisation techniques and the best possible methods for developing the required algorithm for real-time dispatching are selected by conducting research on mathematical-based planning methods. Finally, a real-time dispatching model compatible with the requirement of trucks with different capacities is developed by using two techniques of flow networks and integer programming.
Stability of power systems coupled with market dynamics
NASA Astrophysics Data System (ADS)
Meng, Jianping
This Ph.D. thesis presented here spans two relatively independent topics. The first part, Chapter 2 is self-contained, and is dedicated to studies of new algorithms for power system state estimation. The second part, encompassing the remaining chapters, is dedicated to stability analysis of power system coupled with market dynamics. The first part of this thesis presents improved Newton's methods employing efficient vectorized calculations of higher order derivatives in power system state estimation problems. The improved algorithms are proposed based on an exact Newton's method using the second order terms. By efficiently computing an exact gain matrix, combined with a special optimal multiplier method, the new algorithms show more reliable convergence compared with the existing methods of normal equations, orthogonal decomposition, and Hachtel's sparse tableau. Our methods are able to handle ill-conditioned problems, yet show minimal penalty in computational cost for well-conditioned cases. These claims are illustrated through the standard IEEE 118 and 300 bus test examples. The second part of the thesis focuses on stability analysis of market/power systems. The work presented is motivated by an emerging problem. As the frequency of market based dispatch updates increases, there will inevitably be interaction between the dynamics of markets determining the generator dispatch commands, and the physical response of generators and network interconnections, necessitating the development of stability analysis for such coupled systems. We begin with numeric tests using different market models, with detailed machine/exciter/turbine/governor dynamics, in the New England 39 bus test system. A progression of modeling refinements are introduced, including such non-ideal effects as time delays. Electricity market parameter identification algorithms are also studied based on real time data from the PJM electricity market. Finally our power market model is augmented by optimal power flow constraints, allowing study of the so-called congestion problem. These studies show that understanding of potential modes of instability in such coupled systems is of crucial importance both in designing suitable rules for power markets, and in designing physical generator controls that are complementary to market-based dispatch.
A Real-Time Greedy-Index Dispatching Policy for using PEVs to Provide Frequency Regulation Service
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ke, Xinda; Wu, Di; Lu, Ning
This article presents a real-time greedy-index dispatching policy (GIDP) for using plug-in electric vehicles (PEVs) to provide frequency regulation services. A new service cost allocation mechanism is proposed to award PEVs based on the amount of service they provided, while considering compensations for delayed-charging and reduction of battery lifetime due to participation of the service. The GIDP transforms the optimal dispatch problem from a high-dimensional space into a one-dimensional space while preserving the solution optimality. When solving the transformed problem in real-time, the global optimality of the GIDP solution can be guaranteed by mathematically proved “indexability”. Because the GIDP indexmore » can be calculated upon the PEV’s arrival and used for the entire decision making process till its departure, the computational burden is minimized and the complexity of the aggregator dispatch process is significantly reduced. Finally, simulation results are used to evaluate the proposed GIDP, and to demonstrate the potential profitability from providing frequency regulation service by using PEVs.« less
A Real-Time Greedy-Index Dispatching Policy for using PEVs to Provide Frequency Regulation Service
Ke, Xinda; Wu, Di; Lu, Ning
2017-09-18
This article presents a real-time greedy-index dispatching policy (GIDP) for using plug-in electric vehicles (PEVs) to provide frequency regulation services. A new service cost allocation mechanism is proposed to award PEVs based on the amount of service they provided, while considering compensations for delayed-charging and reduction of battery lifetime due to participation of the service. The GIDP transforms the optimal dispatch problem from a high-dimensional space into a one-dimensional space while preserving the solution optimality. When solving the transformed problem in real-time, the global optimality of the GIDP solution can be guaranteed by mathematically proved “indexability”. Because the GIDP indexmore » can be calculated upon the PEV’s arrival and used for the entire decision making process till its departure, the computational burden is minimized and the complexity of the aggregator dispatch process is significantly reduced. Finally, simulation results are used to evaluate the proposed GIDP, and to demonstrate the potential profitability from providing frequency regulation service by using PEVs.« less
Integrated Canada-U.S. Power Sector Modeling with the Regional Energy Deployment System (ReEDS)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Martinez, A.; Eurek, K.; Mai, T.
2013-02-01
The electric power system in North America is linked between the United States and Canada. Canada has historically been a net exporter of electricity to the United States. The extent to which this remains true will depend on the future evolution of power markets, technology deployment, and policies. To evaluate these and related questions, we modify the Regional Energy Deployment System (ReEDS) model to include an explicit representation of the grid-connected power system in Canada to the continental United States. ReEDS is unique among long-term capacity expansion models for its high spatial resolution and statistical treatment of the impact ofmore » variable renewable generation on capacity planning and dispatch. These unique traits are extended to new Canadian regions. We present example scenario results using the fully integrated Canada-U.S. version of ReEDS to demonstrate model capabilities. The newly developed, integrated Canada-U.S. ReEDS model can be used to analyze the dynamics of electricity transfers and other grid services between the two countries under different scenarios.« less
NASA Astrophysics Data System (ADS)
Venkatesh, Aranya
Increasing concerns about the environmental impacts of fossil fuels used in the U.S. transportation and electricity sectors have spurred interest in alternate energy sources, such as natural gas and biofuels. Life cycle assessment (LCA) methods can be used to estimate the environmental impacts of incumbent energy sources and potential impact reductions achievable through the use of alternate energy sources. Some recent U.S. climate policies have used the results of LCAs to encourage the use of low carbon fuels to meet future energy demands in the U.S. However, the LCA methods used to estimate potential reductions in environmental impact have some drawbacks. First, the LCAs are predominantly based on deterministic approaches that do not account for any uncertainty inherent in life cycle data and methods. Such methods overstate the accuracy of the point estimate results, which could in turn lead to incorrect and (consequent) expensive decision-making. Second, system boundaries considered by most LCA studies tend to be limited (considered a manifestation of uncertainty in LCA). Although LCAs can estimate the benefits of transitioning to energy systems of lower environmental impact, they may not be able to characterize real world systems perfectly. Improved modeling of energy systems mechanisms can provide more accurate representations of reality and define more likely limits on potential environmental impact reductions. This dissertation quantitatively and qualitatively examines the limitations in LCA studies outlined previously. The first three research chapters address the uncertainty in life cycle greenhouse gas (GHG) emissions associated with petroleum-based fuels, natural gas and coal consumed in the U.S. The uncertainty in life cycle GHG emissions from fossil fuels was found to range between 13 and 18% of their respective mean values. For instance, the 90% confidence interval of the life cycle GHG emissions of average natural gas consumed in the U.S was found to range between -8 to 9% (17%) of the mean value of 66 g CO2e/MJ. Results indicate that uncertainty affects the conclusions of comparative life cycle assessments, especially when differences in average environmental impacts between two competing fuels/products are small. In the final two research chapters of this thesis, system boundary limitations in LCA are addressed. Simplified economic dispatch models for are developed to examine changes in regional power plant dispatch that occur when coal power plants are retired and when natural gas prices drop. These models better reflect reality by estimating the order in which existing power plants are dispatched to meet electricity demand based on short-run marginal costs. Results indicate that the reduction in air emissions are lower than suggested by LCA studies, since they generally do not include the complexity of regional electricity grids, predominantly driven by comparative fuel prices. For instance, comparison, this study estimates 7-15% reductions in emissions with low natural gas prices. Although this is a significant reduction in itself, it is still lower than the benefits reported in traditional life cycle comparisons of coal and natural gas-based power (close to 50%), mainly due to the effects of plant dispatch.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palchak, David; Cochran, Jaquelin; Deshmukh, Ranjit
The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Using advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India’s RE targets and identify actions that may be favorable for integration. Our primarymore » tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (Berkeley Lab), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU’s anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD 980 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment—from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India’s 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Palchak, David; Cochran, Jaquelin; Ehlen, Ali
The use of renewable energy (RE) sources, primarily wind and solar generation, is poised to grow significantly within the Indian power system. The Government of India has established a target of 175 gigawatts (GW) of installed RE capacity by 2022, including 60 GW of wind and 100 GW of solar, up from 29 GW wind and 9 GW solar at the beginning of 2017. Thanks to advanced weather and power system modeling made for this project, the study team is able to explore operational impacts of meeting India's RE targets and identify actions that may be favorable for integration. Ourmore » primary tool is a detailed production cost model, which simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. Our team comprises a core group from the Power System Operation Corporation, Ltd. (POSOCO), which is the national grid operator (with representation from the National, Southern, and Western Regional Load Dispatch Centers) under Ministry of Power, National Renewable Energy Laboratory (NREL), and Lawrence Berkeley National Laboratory (LBNL), and a broader modeling team that includes Central Electricity Authority (CEA), POWERGRID (the central transmission utility, CTU), and State Load Dispatch Centers in Maharashtra, Gujarat, Tamil Nadu, Karnataka, Rajasthan, and Andhra Pradesh. Our model includes high-resolution wind and solar data (forecasts and actuals), unique properties for each generator, CEA/CTU's anticipated buildout of the power system, and enforced state-to-state transmission flows. Assuming the fulfillment of current efforts to provide better access to the physical flexibility of the power system, we find that power system balancing with 100 GW of solar and 60 GW of wind is achievable at 15-minute operational timescales with minimal RE curtailment. This RE capacity meets 22% of total projected 2022 electricity consumption in India with annual RE curtailment of 1.4%, in line with experiences in other countries with significant RE penetrations (Bird et al. 2016). Changes to operational practice can further reduce the cost of operating the power system and reduce RE curtailment. Coordinating scheduling and dispatch over a broader area is the largest driver to reduce costs, saving INR 6300 crore (USD $920 million) annually when optimized regionally. Lowering minimum operating levels of coal plants (from 70% to 40%) is the biggest driver to reduce RE curtailment - from 3.5% down to 0.76%. In fact, this operating property is more influential than faster thermal generation ramp rates in lowering the projected levels of curtailment. While this study does not answer every question relevant to planning for India's 2022 RE targets, it is an important step toward analyzing operational challenges and cost saving opportunities using state-of-the-art power system planning tools. Further analysis can build upon this basis to explore optimal renewable resource and intrastate transmission siting, system stability during contingencies, and the influence of total power system investment costs on customer tariffs.« less
NASA Astrophysics Data System (ADS)
Jaramillo, P.; Venkatesh, A.; Griffin, M.; Matthews, S.
2012-12-01
Increased production of unconventional natural gas resources in the U.S. has drastically reduced the price of natural gas. While in 2005 prices went above 10/MMBtu, since 2011 they have been below 3/MMBtu. These low prices have encouraged the increase of natural gas utilization in the United States electricity sector. Natural gas can offset coal for power generation, reducing emissions such as greenhouse gases, sulfur and nitrogen oxides. In quantifying the benefit of offsetting coal by using natural gas, life cycle assessment (LCA) studies have shown up to 50% reductions in life cycle greenhouse gas (GHG) emissions can be expected. However, these studies predominantly use limited system boundaries that contain single individual coal and natural gas power plants. They do not consider (regional) fleets of power plants that are dispatched on the basis of their short-run marginal costs. In this study, simplified economic dispatch models (representing existing power plants in a given region) are developed for three U.S. regions - ERCOT, MISO and PJM. These models, along with historical load data are used to determine how natural gas utilization will increase in the short-term due to changes in natural gas price. The associated changes in fuel mix and life cycle GHG emissions are estimated. Results indicate that life cycle GHG emissions may, at best, decrease by 5-15% as a result of low natural gas prices, compared to almost 50% reductions estimated by previous LCAs. This study thus provides more reasonable estimates of potential reductions in GHG emissions from using natural gas instead of coal in the electricity sector in the short-term.
Integrating plug-in electric vehicles into the electric power system
NASA Astrophysics Data System (ADS)
Wu, Di
This dissertation contributes to our understanding of how plug-in hybrid electric vehicles (PHEVs) and plug-in battery-only electric vehicles (EVs)---collectively termed plug-in electric vehicles (PEVs)---could be successfully integrated with the electric power system. The research addresses issues at a diverse range of levels pertaining to light-duty vehicles, which account for the majority of highway vehicle miles traveled, energy consumed by highway travel modes, and carbon dioxide emissions from on-road sources. Specifically, the following topics are investigated: (i) On-board power electronics topologies for bidirectional vehicle-to-grid and grid-to-vehicle power transfer; (ii) The estimation of the electric energy and power consumption by fleets of light-duty PEVs; (iii) An operating framework for the scheduling and dispatch of electric power by PEV aggregators; (iv) The pricing of electricity by PHEV aggregators and how it affects the decision-making process of a cost-conscious PHEV owner; (v) The impacts on distribution systems from PEVs under aggregator control; (vi) The modeling of light-duty PEVs for long-term energy and transportation planning at a national scale.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Glatzmaier, Greg C.; Rea, J.; Olsen, Michele L.
We are developing a novel concentrating solar electricity-generating technology that is both modular and dispatchable. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) uses concentrated solar flux to generate high-temperature thermal energy, which directly converts to electricity via thermoelectric generators (TEGs), stored within a phase-change material (PCM) for electricity generation at a later time, or both allowing for simultaneous charging of the PCM and electricity generation. STEALS has inherent features that drive its cost-competitive scale to be much smaller than current commercial concentrating solar power (CSP) plants. Most obvious is modularity of the solid-state TEG, which favors smaller scales inmore » the kilowatt range as compared to CSP steam turbines, which are minimally 50 MWe for commercial power plants. Here, we present techno-economic and market analyses that show STEALS can be a cost-effective electricity-generating technology with particular appeal to small-scale microgrid applications. We evaluated levelized cost of energy (LCOE) for STEALS and for a comparable photovoltaic (PV) system with battery storage. For STEALS, we estimated capital costs and the LCOE as functions of the type of PCM including the use of recycled aluminum alloys, and evaluated the cost tradeoffs between plasma spray coatings and solution-based boron coatings that are applied to the wetted surfaces of the PCM subsystem. We developed a probabilistic cost model that accounts for uncertainties in the cost and performance inputs to the LCOE estimation. Our probabilistic model estimated LCOE for a 100-kWe STEALS system that had 5 hours of thermal storage and 8-10 hours of total daily power generation. For these cases, the solar multiple for the heliostat field varied between 1.12 and 1.5. We identified microgrids as a likely market for the STEALS system. We characterized microgrid markets in terms of nominal power, dispatchability, geographic location, and customer type, and specified additional features for STEALS that are needed to meet the needs of this growing power market.« less
A Feeder-Bus Dispatch Planning Model for Emergency Evacuation in Urban Rail Transit Corridors
Wang, Yun; Yan, Xuedong; Zhou, Yu; Zhang, Wenyi
2016-01-01
The mobility of modern metropolises strongly relies on urban rail transit (URT) systems, and such a heavy dependence causes that even minor service interruptions would make the URT systems unsustainable. This study aims at optimally dispatching the ground feeder-bus to coordinate with the urban rails’ operation for eliminating the effect of unexpected service interruptions in URT corridors. A feeder-bus dispatch planning model was proposed for the collaborative optimization of URT and feeder-bus cooperation under emergency situations and minimizing the total evacuation cost of the feeder-buses. To solve the model, a concept of dummy feeder-bus system is proposed to transform the non-linear model into traditional linear programming (ILP) model, i.e., traditional transportation problem. The case study of Line #2 of Nanjing URT in China was adopted to illustrate the model application and sensitivity analyses of the key variables. The modeling results show that as the evacuation time window increases, the total evacuation cost as well as the number of dispatched feeder-buses decrease, and the dispatched feeder-buses need operate for more times along the feeder-bus line. The number of dispatched feeder-buses does not show an obvious change with the increase of parking spot capacity and time window, indicating that simply increasing the parking spot capacity would cause huge waste for the emergent bus utilization. When the unbalanced evacuation demand exists between stations, the more feeder-buses are needed. The method of this study will contribute to improving transportation emergency management and resource allocation for URT systems. PMID:27676179
Information needs for increasing log transport efficiency
Timothy P. McDonald; Steven E. Taylor; Robert B. Rummer; Jorge Valenzuela
2001-01-01
Three methods of dispatching trucks to loggers were tested using a log transport simulation model: random allocation, fixed assignment of trucks to loggers, and dispatch based on knowledge of the current status of trucks and loggers within the system. This 'informed' dispatch algorithm attempted to minimize the difference in time between when a logger would...
Wind farms production: Control and prediction
NASA Astrophysics Data System (ADS)
El-Fouly, Tarek Hussein Mostafa
Wind energy resources, unlike dispatchable central station generation, produce power dependable on external irregular source and that is the incident wind speed which does not always blow when electricity is needed. This results in the variability, unpredictability, and uncertainty of wind resources. Therefore, the integration of wind facilities to utility electrical grid presents a major challenge to power system operator. Such integration has significant impact on the optimum power flow, transmission congestion, power quality issues, system stability, load dispatch, and economic analysis. Due to the irregular nature of wind power production, accurate prediction represents the major challenge to power system operators. Therefore, in this thesis two novel models are proposed for wind speed and wind power prediction. One proposed model is dedicated to short-term prediction (one-hour ahead) and the other involves medium term prediction (one-day ahead). The accuracy of the proposed models is revealed by comparing their results with the corresponding values of a reference prediction model referred to as the persistent model. Utility grid operation is not only impacted by the uncertainty of the future production of wind farms, but also by the variability of their current production and how the active and reactive power exchange with the grid is controlled. To address this particular task, a control technique for wind turbines, driven by doubly-fed induction generators (DFIGs), is developed to regulate the terminal voltage by equally sharing the generated/absorbed reactive power between the rotor-side and the gridside converters. To highlight the impact of the new developed technique in reducing the power loss in the generator set, an economic analysis is carried out. Moreover, a new aggregated model for wind farms is proposed that accounts for the irregularity of the incident wind distribution throughout the farm layout. Specifically, this model includes the wake effect and the time delay of the incident wind speed of the different turbines on the farm, and to simulate the fluctuation in the generated power more accurately and more closer to real-time operation. Recently, wind farms with considerable output power ratings have been installed. Their integrating into the utility grid will substantially affect the electricity markets. This thesis investigates the possible impact of wind power variability, wind farm control strategy, wind energy penetration level, wind farm location, and wind power prediction accuracy on the total generation costs and close to real time electricity market prices. These issues are addressed by developing a single auction market model for determining the real-time electricity market prices.
Modelling utility-scale wind power plants. Part 1: Economics
NASA Astrophysics Data System (ADS)
Milligan, Michael R.
1999-10-01
As the worldwide use of wind turbine generators continues to increase in utility-scale applications, it will become increasingly important to assess the economic and reliability impact of these intermittent resources. Although the utility industry in the United States appears to be moving towards a restructured environment, basic economic and reliability issues will continue to be relevant to companies involved with electricity generation. This article is the first of two which address modelling approaches and results obtained in several case studies and research projects at the National Renewable Energy Laboratory (NREL). This first article addresses the basic economic issues associated with electricity production from several generators that include large-scale wind power plants. An important part of this discussion is the role of unit commitment and economic dispatch in production cost models. This paper includes overviews and comparisons of the prevalent production cost modelling methods, including several case studies applied to a variety of electric utilities. The second article discusses various methods of assessing capacity credit and results from several reliability-based studies performed at NREL.
Chassin, David P.; Behboodi, Sahand; Djilali, Ned
2018-01-28
This article proposes a system-wide optimal resource dispatch strategy that enables a shift from a primarily energy cost-based approach, to a strategy using simultaneous price signals for energy, power and ramping behavior. A formal method to compute the optimal sub-hourly power trajectory is derived for a system when the price of energy and ramping are both significant. Optimal control functions are obtained in both time and frequency domains, and a discrete-time solution suitable for periodic feedback control systems is presented. The method is applied to North America Western Interconnection for the planning year 2024, and it is shown that anmore » optimal dispatch strategy that simultaneously considers both the cost of energy and the cost of ramping leads to significant cost savings in systems with high levels of renewable generation: the savings exceed 25% of the total system operating cost for a 50% renewables scenario.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chassin, David P.; Behboodi, Sahand; Djilali, Ned
This article proposes a system-wide optimal resource dispatch strategy that enables a shift from a primarily energy cost-based approach, to a strategy using simultaneous price signals for energy, power and ramping behavior. A formal method to compute the optimal sub-hourly power trajectory is derived for a system when the price of energy and ramping are both significant. Optimal control functions are obtained in both time and frequency domains, and a discrete-time solution suitable for periodic feedback control systems is presented. The method is applied to North America Western Interconnection for the planning year 2024, and it is shown that anmore » optimal dispatch strategy that simultaneously considers both the cost of energy and the cost of ramping leads to significant cost savings in systems with high levels of renewable generation: the savings exceed 25% of the total system operating cost for a 50% renewables scenario.« less
The state of energy storage in electric utility systems and its effect on renewable energy resources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rau, N S
1994-08-01
This report describes the state of the art of electric energy storage technologies and discusses how adding intermittent renewable energy technologies (IRETs) to a utility network affects the benefits from storage dispatch. Load leveling was the mode of storage dispatch examined in the study. However, the report recommended that other modes be examined in the future for kilowatt and kilowatt-hour optimization of storage. The motivation to install storage with IRET generation can arise from two considerations: reliability and enhancement of the value of energy. Because adding storage increases cost, reliability-related storage is attractive only if the accruing benefits exceed themore » cost of storage installation. The study revealed that the operation of storage should not be guided by the output of the IRET but rather by system marginal costs. Consequently, in planning studies to quantify benefits, storage should not be considered as an entity belonging to the system and not as a component of IRETS. The study also indicted that because the infusion of IRET energy tends to reduce system marginal cost, the benefits from load leveling (value of energy) would be reduced. However, if a system has storage, particularly if the storage is underutilized, its dispatch can be reoriented to enhance the benefits of IRET integration.« less
Short run effects of a price on carbon dioxide emissions from U.S. electric generators.
Newcomer, Adam; Blumsack, Seth A; Apt, Jay; Lave, Lester B; Morgan, M Granger
2008-05-01
The price of delivered electricity will rise if generators have to pay for carbon dioxide emissions through an implicit or explicit mechanism. There are two main effects that a substantial price on CO2 emissions would have in the short run (before the generation fleet changes significantly). First, consumers would react to increased price by buying less, described by their price elasticity of demand. Second, a price on CO2 emissions would change the order in which existing generators are economically dispatched, depending on their carbon dioxide emissions and marginal fuel prices. Both the price increase and dispatch changes depend on the mix of generation technologies and fuels in the region available for dispatch, although the consumer response to higher prices is the dominant effect. We estimate that the instantaneous imposition of a price of $35 per metric ton on CO2 emissions would lead to a 10% reduction in CO2 emissions in PJM and MISO at a price elasticity of -0.1. Reductions in ERCOT would be about one-third as large. Thus, a price on CO2 emissions that has been shown in earlier workto stimulate investment in new generation technology also provides significant CO2 reductions before new technology is deployed at large scale.
Operationalizing clean development mechanism baselines: A case study of China's electrical sector
NASA Astrophysics Data System (ADS)
Steenhof, Paul A.
The global carbon market is rapidly developing as the first commitment period of the Kyoto Protocol draws closer and Parties to the Protocol with greenhouse gas (GHG) emission reduction targets seek alternative ways to reduce their emissions. The Protocol includes the Clean Development Mechanism (CDM), a tool that encourages project-based investments to be made in developing nations that will lead to an additional reduction in emissions. Due to China's economic size and rate of growth, technological characteristics, and its reliance on coal, it contains a large proportion of the global CDM potential. As China's economy modernizes, more technologies and processes are requiring electricity and demand for this energy source is accelerating rapidly. Relatively inefficient technology to generate electricity in China thereby results in the electrical sector having substantial GHG emission reduction opportunities as related to the CDM. In order to ensure the credibility of the CDM in leading to a reduction in GHG emissions, it is important that the baseline method used in the CDM approval process is scientifically sound and accessible for both others to use and for evaluation purposes. Three different methods for assessing CDM baselines and environmental additionality are investigated in the context of China's electrical sector: a method based on a historical perspective of the electrical sector (factor decomposition), a method structured upon a current perspective (operating and build margins), and a simulation of the future (dispatch analysis). Assessing future emission levels for China's electrical sector is a very challenging task given the complexity of the system, its dynamics, and that it is heavily influenced by internal and external forces, but of the different baseline methods investigated, dispatch modelling is best suited for the Chinese context as it is able to consider the important regional and temporal dimensions of its economy and its future development. For China, the most promising options for promoting sustainable development, one of the goals of the Kyoto Protocol, appear to be tied to increasing electrical end-use and generation efficiency, particularly clean coal technology for electricity generation since coal will likely continue to be a dominant primary fuel.
NASA Astrophysics Data System (ADS)
McLarty, Dustin Fogle
Distributed energy systems are a promising means by which to reduce both emissions and costs. Continuous generators must be responsive and highly efficiency to support building dynamics and intermittent on-site renewable power. Fuel cell -- gas turbine hybrids (FC/GT) are fuel-flexible generators capable of ultra-high efficiency, ultra-low emissions, and rapid power response. This work undertakes a detailed study of the electrochemistry, chemistry and mechanical dynamics governing the complex interaction between the individual systems in such a highly coupled hybrid arrangement. The mechanisms leading to the compressor stall/surge phenomena are studied for the increased risk posed to particular hybrid configurations. A novel fuel cell modeling method introduced captures various spatial resolutions, flow geometries, stack configurations and novel heat transfer pathways. Several promising hybrid configurations are analyzed throughout the work and a sensitivity analysis of seven design parameters is conducted. A simple estimating method is introduced for the combined system efficiency of a fuel cell and a turbine using component performance specifications. Existing solid oxide fuel cell technology is capable of hybrid efficiencies greater than 75% (LHV) operating on natural gas, and existing molten carbonate systems greater than 70% (LHV). A dynamic model is calibrated to accurately capture the physical coupling of a FC/GT demonstrator tested at UC Irvine. The 2900 hour experiment highlighted the sensitivity to small perturbations and a need for additional control development. Further sensitivity studies outlined the responsiveness and limits of different control approaches. The capability for substantial turn-down and load following through speed control and flow bypass with minimal impact on internal fuel cell thermal distribution is particularly promising to meet local demands or provide dispatchable support for renewable power. Advanced control and dispatch heuristics are discussed using a case study of the UCI central plant. Thermal energy storage introduces a time horizon into the dispatch optimization which requires novel solution strategies. Highly efficient and responsive generators are required to meet the increasingly dynamic loads of today's efficient buildings and intermittent local renewable wind and solar power. Fuel cell gas turbine hybrids will play an integral role in the complex and ever-changing solution to local electricity production.
Weis, Allison; Michalek, Jeremy J; Jaramillo, Paulina; Lueken, Roger
2015-05-05
We develop a unit commitment and economic dispatch model to estimate the operation costs and the air emissions externality costs attributable to new electric vehicle electricity demand under controlled vs uncontrolled charging schemes. We focus our analysis on the PJM Interconnection and use scenarios that characterize (1) the most recent power plant fleet for which sufficient data are available, (2) a hypothetical 2018 power plant fleet that reflects upcoming plant retirements, and (3) the 2018 fleet with increased wind capacity. We find that controlled electric vehicle charging can reduce associated generation costs by 23%-34% in part by shifting loads to lower-cost, higher-emitting coal plants. This shift results in increased externality costs of health and environmental damages from increased air pollution. On balance, we find that controlled charging of electric vehicles produces negative net social benefits in the recent PJM grid but could have positive net social benefits in a future grid with sufficient coal retirements and wind penetration.
A coordination theory for intelligent machines
NASA Technical Reports Server (NTRS)
Wang, Fei-Yue; Saridis, George N.
1990-01-01
A formal model for the coordination level of intelligent machines is established. The framework of the coordination level investigated consists of one dispatcher and a number of coordinators. The model called coordination structure has been used to describe analytically the information structure and information flow for the coordination activities in the coordination level. Specifically, the coordination structure offers a formalism to (1) describe the task translation of the dispatcher and coordinators; (2) represent the individual process within the dispatcher and coordinators; (3) specify the cooperation and connection among the dispatcher and coordinators; (4) perform the process analysis and evaluation; and (5) provide a control and communication mechanism for the real-time monitor or simulation of the coordination process. A simple procedure for the task scheduling in the coordination structure is presented. The task translation is achieved by a stochastic learning algorithm. The learning process is measured with entropy and its convergence is guaranteed. Finally, a case study of the coordination structure with three coordinators and one dispatcher for a simple intelligent manipulator system illustrates the proposed model and the simulation of the task processes performed on the model verifies the soundness of the theory.
NASA Astrophysics Data System (ADS)
Li, Xiwang
Buildings consume about 41.1% of primary energy and 74% of the electricity in the U.S. Moreover, it is estimated by the National Energy Technology Laboratory that more than 1/4 of the 713 GW of U.S. electricity demand in 2010 could be dispatchable if only buildings could respond to that dispatch through advanced building energy control and operation strategies and smart grid infrastructure. In this study, it is envisioned that neighboring buildings will have the tendency to form a cluster, an open cyber-physical system to exploit the economic opportunities provided by a smart grid, distributed power generation, and storage devices. Through optimized demand management, these building clusters will then reduce overall primary energy consumption and peak time electricity consumption, and be more resilient to power disruptions. Therefore, this project seeks to develop a Net-zero building cluster simulation testbed and high fidelity energy forecasting models for adaptive and real-time control and decision making strategy development that can be used in a Net-zero building cluster. The following research activities are summarized in this thesis: 1) Development of a building cluster emulator for building cluster control and operation strategy assessment. 2) Development of a novel building energy forecasting methodology using active system identification and data fusion techniques. In this methodology, a systematic approach for building energy system characteristic evaluation, system excitation and model adaptation is included. The developed methodology is compared with other literature-reported building energy forecasting methods; 3) Development of the high fidelity on-line building cluster energy forecasting models, which includes energy forecasting models for buildings, PV panels, batteries and ice tank thermal storage systems 4) Small scale real building validation study to verify the performance of the developed building energy forecasting methodology. The outcomes of this thesis can be used for building cluster energy forecasting model development and model based control and operation optimization. The thesis concludes with a summary of the key outcomes of this research, as well as a list of recommendations for future work.
Design of a thermosyphon-based thermal valve for controlled high-temperature heat extraction
Oshman, Christopher; Hardin, Corey; Rea, Jonathan; ...
2017-01-16
Conventional concentrated solar power (CSP) is a reliable alternative energy source that uses the sun’s heat to drive a heat engine to produce electrical power. An advantage of CSP is its ability to store thermal energy for use during off-sun hours which is typically done by storing sensible heat in molten salts. Alternatively, thermal energy may be stored as latent heat in a phase-change material (PCM), which stores large quantities of thermal energy in an isothermal process. On-sun, the PCM melts, storing energy. Off-sun, the latent heat is extracted to produce dispatchable electrical power. Here, this paper presents the designmore » of a thermosyphon-based device with sodium working fluid that is able to extract heat from a source as demand requires. A prototype has been designed to transfer 37 kW of thermal energy from a 600°C molten PCM tank to an array of 9% efficient thermoelectric generators (TEGs) to produce 3 kW of usable electrical energy for 5 h. This “thermal valve” design incorporates a funnel to collect condensate and a central shut-off valve to control condensate gravity return to the evaporator. Three circumferential tubes allow vapour transport up to the condenser. Pressure and a thermal resistance models were developed to predict the performance of the thermal valve. The pressure model predicts that the thermal valve will function as designed. The thermal resistance model predicts a 5500× difference in total thermal resistance between “on” and “off” states. The evaporator and condenser walls comprise 96% of the “on” thermal resistance, while the small parasitic heat transfer in the “off” state is primarily (77%) due to radiation losses. Lastly, this simple and effective technology can have a strong impact on the feasibility, scalability, and dispatchability of CSP latent storage. In addition, other industrial and commercial applications can benefit from this thermal valve concept.« less
Design of a thermosyphon-based thermal valve for controlled high-temperature heat extraction
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oshman, Christopher; Hardin, Corey; Rea, Jonathan
Conventional concentrated solar power (CSP) is a reliable alternative energy source that uses the sun’s heat to drive a heat engine to produce electrical power. An advantage of CSP is its ability to store thermal energy for use during off-sun hours which is typically done by storing sensible heat in molten salts. Alternatively, thermal energy may be stored as latent heat in a phase-change material (PCM), which stores large quantities of thermal energy in an isothermal process. On-sun, the PCM melts, storing energy. Off-sun, the latent heat is extracted to produce dispatchable electrical power. Here, this paper presents the designmore » of a thermosyphon-based device with sodium working fluid that is able to extract heat from a source as demand requires. A prototype has been designed to transfer 37 kW of thermal energy from a 600°C molten PCM tank to an array of 9% efficient thermoelectric generators (TEGs) to produce 3 kW of usable electrical energy for 5 h. This “thermal valve” design incorporates a funnel to collect condensate and a central shut-off valve to control condensate gravity return to the evaporator. Three circumferential tubes allow vapour transport up to the condenser. Pressure and a thermal resistance models were developed to predict the performance of the thermal valve. The pressure model predicts that the thermal valve will function as designed. The thermal resistance model predicts a 5500× difference in total thermal resistance between “on” and “off” states. The evaporator and condenser walls comprise 96% of the “on” thermal resistance, while the small parasitic heat transfer in the “off” state is primarily (77%) due to radiation losses. Lastly, this simple and effective technology can have a strong impact on the feasibility, scalability, and dispatchability of CSP latent storage. In addition, other industrial and commercial applications can benefit from this thermal valve concept.« less
Nuclear Hybrid Energy Systems Initial Integrated Case Study Development and Analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Harrison, Thomas J.; Greenwood, Michael Scott
The US Department of Energy Office of Nuclear Energy established the Nuclear Hybrid Energy System (NHES) project to develop a systematic, rigorous, technically accurate set of methods to model, analyze, and optimize the integration of dispatchable nuclear, fossil, and electric storage with an industrial customer. Ideally, the optimized integration of these systems will provide economic and operational benefits to the overall system compared to independent operation, and it will enhance the stability and responsiveness of the grid as intermittent, nondispatchable, renewable resources provide a greater share of grid power.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Energy Operation Model (EOM) simulates the operation of the electric grid at the zonal scale, including inter-zonal transmission constraints. It generates the production cost, power generation by plant and category, fuel usage, and locational marginal price (LMP) with a flexible way to constrain the power production by environmental constraints, e.g. heat waves, drought conditions). Different from commercial software such as PROMOD IV where generator capacity and heat rate efficiency can only be adjusted on a monthly basis, EOM calculates capacity impacts and plant efficiencies based on hourly ambient conditions (air temperature and humidity) and cooling water availability for thermal plants.more » What is missing is a hydro power dispatch.« less
NASA Astrophysics Data System (ADS)
Cope, Robert Frank, III
1998-12-01
The electric utility industry in the United States is currently experiencing a new and different type of growing pain. It is the pain of having to restructure itself into a competitive business. Many industry experts are trying to explain how the nation as a whole, as well as individual states, will implement restructuring and handle its numerous "transition problems." One significant transition problem for federal and state regulators rests with determining a utility's stranded costs. Stranded generation facilities are assets which would be uneconomic in a competitive environment or costs for assets whose regulated book value is greater than market value. At issue is the methodology which will be used to estimate stranded costs. The two primary methods are known as "Top-Down" and "Bottom-Up." The "Top-Down" approach simply determines the present value of the losses in revenue as the market price for electricity changes over a period of time into the future. The problem with this approach is that it does not take into account technical issues associated with the generation and wheeling of electricity. The "Bottom-Up" approach computes the present value of specific strandable generation facilities and compares the resulting valuations with their historical costs. It is regarded as a detailed and difficult, but more precise, approach to identifying stranded assets and their associated costs. This dissertation develops a "Bottom-Up" quantitative, optimization-based approach to electric power wheeling within the state of Louisiana. It optimally evaluates all production capabilities and coordinates the movement of bulk power through transmission interconnections of competing companies in and around the state. Sensitivity analysis to this approach is performed by varying seasonal consumer demand, electric power imports, and transmission inter-connection cost parameters. Generation facility economic dispatch and transmission interconnection bulk power transfers, specific to each set of parameters, lead to the identification of stranded generation facilities. Stranded costs of non-dispatched and uneconomically dispatched generation facilities can then be estimated to indicate, arguably, the largest portion of restructuring transition costs as the industry is transformed from its present monopolistic structure to a competitive one.
Dynamic management of integrated residential energy systems
NASA Astrophysics Data System (ADS)
Muratori, Matteo
This study combines principles of energy systems engineering and statistics to develop integrated models of residential energy use in the United States, to include residential recharging of electric vehicles. These models can be used by government, policymakers, and the utility industry to provide answers and guidance regarding the future of the U.S. energy system. Currently, electric power generation must match the total demand at each instant, following seasonal patterns and instantaneous fluctuations. Thus, one of the biggest drivers of costs and capacity requirement is the electricity demand that occurs during peak periods. These peak periods require utility companies to maintain operational capacity that often is underutilized, outdated, expensive, and inefficient. In light of this, flattening the demand curve has long been recognized as an effective way of cutting the cost of producing electricity and increasing overall efficiency. The problem is exacerbated by expected widespread adoption of non-dispatchable renewable power generation. The intermittent nature of renewable resources and their non-dispatchability substantially limit the ability of electric power generation of adapting to the fluctuating demand. Smart grid technologies and demand response programs are proposed as a technical solution to make the electric power demand more flexible and able to adapt to power generation. Residential demand response programs offer different incentives and benefits to consumers in response to their flexibility in the timing of their electricity consumption. Understanding interactions between new and existing energy technologies, and policy impacts therein, is key to driving sustainable energy use and economic growth. Comprehensive and accurate models of the next-generation power system allow for understanding the effects of new energy technologies on the power system infrastructure, and can be used to guide policy, technology, and economic decisions. This dissertation presents a bottom-up highly resolved model of a generic residential energy eco-system in the United States. The model is able to capture the entire energy footprint of an individual household, to include all appliances, space conditioning systems, in-home charging of plug-in electric vehicles, and any other energy needs, viewing residential and transportation energy needs as an integrated continuum. The residential energy eco-system model is based on a novel bottom-up approach that quantifies consumer energy use behavior. The incorporation of stochastic consumer behaviors allows capturing the electricity consumption of each residential specific end-use, providing an accurate estimation of the actual amount of available controllable resources, and for a better understanding of the potential of residential demand response programs. A dynamic energy management framework is then proposed to manage electricity consumption inside each residential energy eco-system. Objective of the dynamic energy management framework is to optimize the scheduling of all the controllable appliances and in-home charging of plug-in electric vehicles to minimize cost. Such an automated energy management framework is used to simulate residential demand response programs, and evaluate their impact on the electric power infrastructure. For instance, time-varying electricity pricing might lead to synchronization of the individual residential demands, creating pronounced rebound peaks in the aggregate demand that are higher and steeper than the original demand peaks that the time-varying electricity pricing structure intended to eliminate. The modeling tools developed in this study can serve as a virtual laboratory for investigating fundamental economic and policy-related questions regarding the interplay of individual consumers with energy use. The models developed allow for evaluating the impact of different energy policies, technology adoption, and electricity price structures on the total residential electricity demand. In particular, two case studies are reported in this dissertation to illustrate application of the tools developed. The first considers the impact of market penetration of plug-in electric vehicles on the electric power infrastructure. The second provides a quantitative comparison of the impact of different electricity price structures on residential demand response. Simulation results and an electricity price structure, called Multi-TOU, aimed at solving the rebound peak issue, are presented.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin; Palchak, David
The Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid study uses advanced weather and power system modeling to explore the operational impacts of meeting India's 2022 renewable energy targets and identify actions that may be favorable for integrating high levels of renewable energy into the Indian grid. The study relies primarily on a production cost model that simulates optimal scheduling and dispatch of available generation in a future year (2022) by minimizing total production costs subject to physical, operational, and market constraints. This fact sheet provides a detailed look at each of thesemore » models, including their common assumptions and the insights provided by each.« less
NASA Astrophysics Data System (ADS)
Banka, John Czeslaw
The world strives for more clean and renewable energy, but the amount of dispatchable energy in river networks is not accurately known and difficult to assess. When wind is integrated with water, the dispatchable yield can be greatly increased, but the uncertainty of the wind further degrades predictability. This thesis demonstrates how simulating the flows is a river network integrated with wind over a long time domain yields a solution. Time-shifting the freshet and pumped storage will ameliorate the seasonal summer drought; the risk of ice jams and uncontrolled flooding is reduced. An artificial market eliminates the issue of surplus energy from wind at night. Furthermore, this thesis shows how the necessary infrastructure can be built to accomplish the goals of the intended research. While specific to Northern Ontario and sensitive to the lives of the Native peoples living there, it indicates where the research might be applicable elsewhere in the world.
Assessment of the Electrification of the Road Transport Sector on Net System Emissions
NASA Astrophysics Data System (ADS)
Miller, James
As worldwide environmental consciousness grows, electric vehicles (EVs) are becoming more common and despite the incredible potential for emissions reduction, the net emissions of the power system supply side plus the transportation system are dependent on the generation matrix. Current EV charging patterns tend to correspond directly with the peak consumption hours and have the potential to increase demand sharply allowing for only a small penetration of Electric Vehicles. Using the National Household Travel Survey (NHTS) data a model is created for vehicle travel patterns using trip chaining. Charging schemes are modeled to include uncontrolled residential, uncontrolled residential/industrial charging, optimized charging and optimized charging with vehicle to grid discharging. A charging profile is then determined based upon the assumption that electric vehicles would directly replace a percentage of standard petroleum-fueled vehicles in a known system. Using the generation profile for the specified region, a unit commitment model is created to establish not only the generation dispatch, but also the net CO2 profile for variable EV penetrations and charging profiles. This model is then used to assess the impact of the electrification of the road transport sector on the system net emissions.
Stochastic Optimization for Unit Commitment-A Review
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zheng, Qipeng P.; Wang, Jianhui; Liu, Andrew L.
2015-07-01
Optimization models have been widely used in the power industry to aid the decision-making process of scheduling and dispatching electric power generation resources, a process known as unit commitment (UC). Since UC's birth, there have been two major waves of revolution on UC research and real life practice. The first wave has made mixed integer programming stand out from the early solution and modeling approaches for deterministic UC, such as priority list, dynamic programming, and Lagrangian relaxation. With the high penetration of renewable energy, increasing deregulation of the electricity industry, and growing demands on system reliability, the next wave ismore » focused on transitioning from traditional deterministic approaches to stochastic optimization for unit commitment. Since the literature has grown rapidly in the past several years, this paper is to review the works that have contributed to the modeling and computational aspects of stochastic optimization (SO) based UC. Relevant lines of future research are also discussed to help transform research advances into real-world applications.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Obradovich, Jodi H.
2011-09-30
This paper describes research that is part of an ongoing project to design tools to assist in the integration of renewable energy into the electric grid. These tools will support control room dispatchers in real-time system operations of the electric power transmission system which serves much of the Western United States. Field observations comprise the first phase of this research in which 15 operators have been observed over various shifts and times of day for approximately 90 hours. Findings describing some of the cognitive and environmental challenges of managing the dynamically changing electric grid are presented.
The report reviews information and estimated costs on 15 emissioncontrol technology categories applicable to existing coal-fired electric utility boilers. he categories include passive controls such as least emission dispatching, conventional processes, and emerging technologies ...
Reliability evaluation of microgrid considering incentive-based demand response
NASA Astrophysics Data System (ADS)
Huang, Ting-Cheng; Zhang, Yong-Jun
2017-07-01
Incentive-based demand response (IBDR) can guide customers to adjust their behaviour of electricity and curtail load actively. Meanwhile, distributed generation (DG) and energy storage system (ESS) can provide time for the implementation of IBDR. The paper focus on the reliability evaluation of microgrid considering IBDR. Firstly, the mechanism of IBDR and its impact on power supply reliability are analysed. Secondly, the IBDR dispatch model considering customer’s comprehensive assessment and the customer response model are developed. Thirdly, the reliability evaluation method considering IBDR based on Monte Carlo simulation is proposed. Finally, the validity of the above models and method is studied through numerical tests on modified RBTS Bus6 test system. Simulation results demonstrated that IBDR can improve the reliability of microgrid.
Harmsen, Annelieke Maria Karien; Giannakopoulos, Georgios; Franschman, Gaby; Christiaans, Herman; Bloemers, Frank
2017-04-01
Prehospital communication with Emergency Medical Services (EMS) is carried out in hectic situations. Proper communication among all medical personal is required to enhance collaboration, to provide the best care and enable shared situational awareness. The objective of this article was to give insight into current Dutch prehospital emergency care communication among all EMS and evaluate the usage of a new physician staffed helicopter EMS (P-HEMS) cancellation model. Trauma-related P-HEMS dispatches between November 1, 2014 and May 31, 2015 for the Lifeliner 1 were included; a random sample of 100 dispatches was generated. Tape recordings on all verbal prehospital communication between the dispatch center, EMS, and P-HEMS were transcribed and analyzed. Qualitative content analysis was performed, using open coding to code key messages. Ninety-two tape recordings were analyzed. The most frequent reason for P-HEMS dispatch was suspicion of brain injury (24%). The cancellation model was followed in 66%, overruled in 9%, and not applicable in 25%. The main reason for not adhering to the model was hemodynamic stability. In 5% of P-HEMS dispatches, a complete ABCD (airway, breathing, circulation, disability) methodology was used for handover, in 9% a complete Situation-Background-Assessment-Recommendation technique, in 2% a complete Mechanism-Injuries-Signs-Treatment method was used. The other handovers were incomplete. Prehospital handover between EMS on-scene and P-HEMS often entails insufficient information. The cancellation model for P-HEMS is frequently used and promotes adequate information transfer. To increase joined decision-making, more patient and situational information needs to be handed over. Standardization of prehospital trauma handovers will facilitate this and improve trauma patient's outcome. Copyright © 2016 Elsevier Inc. All rights reserved.
An Energy Integrated Dispatching Strategy of Multi- energy Based on Energy Internet
NASA Astrophysics Data System (ADS)
Jin, Weixia; Han, Jun
2018-01-01
Energy internet is a new way of energy use. Energy internet achieves energy efficiency and low cost by scheduling a variety of different forms of energy. Particle Swarm Optimization (PSO) is an advanced algorithm with few parameters, high computational precision and fast convergence speed. By improving the parameters ω, c1 and c2, PSO can improve the convergence speed and calculation accuracy. The objective of optimizing model is lowest cost of fuel, which can meet the load of electricity, heat and cold after all the renewable energy is received. Due to the different energy structure and price in different regions, the optimization strategy needs to be determined according to the algorithm and model.
Economic dispatch optimization for system integrating renewable energy sources
NASA Astrophysics Data System (ADS)
Jihane, Kartite; Mohamed, Cherkaoui
2018-05-01
Nowadays, the use of energy is growing especially in transportation and electricity industries. However this energy is based on conventional sources which pollute the environment. Multi-source system is seen as the best solution to sustainable development. This paper proposes the Economic Dispatch (ED) of hybrid renewable power system. The hybrid system is composed of ten thermal generators, photovoltaic (PV) generator and wind turbine generator. To show the importance of renewable energy sources (RES) in the energy mix we have ran the simulation for system integrated PV only and PV plus wind. The result shows that the system with renewable energy sources (RES) is more compromising than the system without RES in terms of fuel cost.
Review of the WECC EDT phase 2 EIM benefits analysis and results report.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Veselka, T.D.; Poch, L.A.; Botterud, A.
A region-wide Energy Imbalance Market (EIM) was recently proposed by the Western Electricity Coordinating Council (WECC). In order for the Western Area Power Administration (Western) to make more informed decisions regarding its involvement in the EIM, Western asked Argonne National Laboratory (Argonne) to review the EIM benefits study (the October 2011 revision) performed by Energy and Environmental Economics, Inc. (E3). Key components of the E3 analysis made use of results from a study conducted by the National Renewable Energy Laboratory (NREL); therefore, we also reviewed the NREL work. This report examines E3 and NREL methods and models used in themore » EIM study. Estimating EIM benefits is very challenging because of the complex nature of the Western Interconnection (WI), the variability and uncertainty of renewable energy resources, and the complex decisions and potentially strategic bidding of market participants. Furthermore, methodologies used for some of the more challenging aspects of the EIM have not yet matured. This review is complimentary of several components of the EIM study. Analysts and modelers clearly took great care when conducting detailed simulations of the WI using well-established industry tools under stringent time and budget constraints. However, it is our opinion that the following aspects of the study and the interpretation of model results could be improved upon in future analyses. The hurdle rate methodology used to estimate current market inefficiencies does not directly model the underlying causes of sub-optimal dispatch and power flows. It assumes that differences between historical flows and modeled flows can be attributed solely to market inefficiencies. However, flow differences between model results and historical data can be attributed to numerous simplifying assumptions used in the model and in the input data. We suggest that alternative approaches be explored in order to better estimate the benefits of introducing market structures like the EIM. In addition to more efficient energy transactions in the WI, the EIM would reduce the amount of flexibility reserves needed to accommodate forecast errors associated with variable production from wind and solar energy resources. The modeling approach takes full advantage of variable resource diversity over the entire market footprint, but the projected reduction in flexibility reserves may be overly optimistic. While some reduction would undoubtedly occur, the EIM is only an energy market and would therefore not realize the same reduction in reserves as an ancillary services market. In our opinion the methodology does not adequately capture the impact of transmission constraints on the deployment of flexibility reserves. Estimates of flexibility reserves assume that forecast errors follow a normal distribution. Improved estimates could be obtained by using other probability distributions to estimate up and down reserves to capture the underlying uncertainty of these resources under specific operating conditions. Also, the use of a persistence forecast method for solar is questionable, because solar insolation follows a deterministic pattern dictated by the sun's path through the sky. We suggest a more rigorous method for forecasting solar insolation using the sun's relatively predictable daily pattern at specific locations. The EIM study considered only one scenario for hydropower resources. While this scenario is within the normal range over the WI footprint, it represents a severe drought condition in the Colorado River Basin from which Western schedules power. Given hydropower's prominent role in the WI, we recommend simulating a range of hydropower conditions since the relationship between water availability and WI dispatch costs is nonlinear. Also, the representation of specific operational constraints faced by hydropower operators in the WI needs improvements. The model used in the study cannot fully capture all of the EIM impacts and complexities of power system operations. In particular, a primary benefit of the EIM is a shorter dispatch interval; namely, 5 minutes. However, the model simulates the dispatch hourly. Therefore it cannot adequately measure the benefits of a more frequent dispatch. A tool with a finer time resolution would significantly improve simulation accuracy. When the study was conducted, the rules for the EIM were not clearly defined and it was appropriate to estimate societal benefits of the EIM assuming a perfect market without a detailed specification of the market design. However, incorporating a more complete description of market rules will allow for better estimates of EIM benefits. Furthermore, performing analyses using specific market rules can identify potential design flaws that may be difficult and expensive to correct after the market is established. Estimated cost savings from a more efficient dispatch are less than one percent of the total cost of electricity production.« less
Decentralized and Modular Electrical Architecture
NASA Astrophysics Data System (ADS)
Elisabelar, Christian; Lebaratoux, Laurence
2014-08-01
This paper presents the studies made on the definition and design of a decentralized and modular electrical architecture that can be used for power distribution, active thermal control (ATC), standard inputs-outputs electrical interfaces.Traditionally implemented inside central unit like OBC or RTU, these interfaces can be dispatched in the satellite by using MicroRTU.CNES propose a similar approach of MicroRTU. The system is based on a bus called BRIO (Bus Réparti des IO), which is composed, by a power bus and a RS485 digital bus. BRIO architecture is made with several miniature terminals called BTCU (BRIO Terminal Control Unit) distributed in the spacecraft.The challenge was to design and develop the BTCU with very little volume, low consumption and low cost. The standard BTCU models are developed and qualified with a configuration dedicated to ATC, while the first flight model will fly on MICROSCOPE for PYRO actuations and analogue acquisitions. The design of the BTCU is made in order to be easily adaptable for all type of electric interface needs.Extension of this concept is envisaged for power conditioning and distribution unit, and a Modular PCDU based on BRIO concept is proposed.
Electricity demand and storage dispatch modeling for buildings and implications for the smartgrid
NASA Astrophysics Data System (ADS)
Zheng, Menglian; Meinrenken, Christoph
2013-04-01
As an enabler for demand response (DR), electricity storage in buildings has the potential to lower costs and carbon footprint of grid electricity while simultaneously mitigating grid strain and increasing its flexibility to integrate renewables (central or distributed). We present a stochastic model to simulate minute-by-minute electricity demand of buildings and analyze the resulting electricity costs under actual, currently available DR-enabling tariffs in New York State, namely a peak/offpeak tariff charging by consumed energy (monthly total kWh) and a time of use tariff charging by power demand (monthly peak kW). We then introduce a variety of electrical storage options (from flow batteries to flywheels) and determine how DR via temporary storage may increase the overall net present value (NPV) for consumers (comparing the reduced cost of electricity to capital and maintenance costs of the storage). We find that, under the total-energy tariff, only medium-term storage options such as batteries offer positive NPV, and only at the low end of storage costs (optimistic scenario). Under the peak-demand tariff, however, even short-term storage such as flywheels and superconducting magnetic energy offer positive NPV. Therefore, these offer significant economic incentive to enable DR without affecting the consumption habits of buildings' residents. We discuss implications for smartgrid communication and our future work on real-time price tariffs.
O'Shea, R; Wall, D; Murphy, J D
2016-09-01
Four feedstocks were assessed for use in a demand driven biogas system. Biomethane potential (BMP) assays were conducted for grass silage, food waste, Laminaria digitata and dairy cow slurry. Semi-continuous trials were undertaken for all feedstocks, assessing biogas and biomethane production. Three kinetic models of the semi-continuous trials were compared. A first order model most accurately correlated with gas production in the pulse fed semi-continuous system. This model was developed for production of electricity on demand, and biomethane upgrading. The model examined a theoretical grass silage digester that would produce 435kWe in a continuous fed system. Adaptation to demand driven biogas required 187min to produce sufficient methane to run a 2MWe combined heat and power (CHP) unit for 60min. The upgrading system was dispatched 71min following CHP shutdown. Of the biogas produced 21% was used in the CHP and 79% was used in the upgrading system. Copyright © 2016 Elsevier Ltd. All rights reserved.
Hybrid Geo-Energy Systems for Energy Storage and Dispatchable Renewable and Low-Carbon Electricity
NASA Astrophysics Data System (ADS)
Buscheck, Thomas; Bielicki, Jeffrey; Ogland-Hand, Jonathan; Hao, Yue; Sun, Yunwei; Randolph, Jimmy; Saar, Martin
2015-04-01
Three primary challenges for energy systems are to (1) reduce the amount of carbon dioxide (CO2) being emitted to the atmosphere, (2) increase the penetration of renewable energy technologies, and (3) reduce the water intensity of energy production. Integrating variable renewable energy sources (wind, sunlight) into electric grids requires advances in energy storage approaches, which are currently expensive, and tend to have limited capacity and/or geographic deployment potential. Our approach uses CO2, that would otherwise be emitted to the atmosphere, to generate electricity from geothermal resources, to store excess energy from variable (wind, solar photovoltaic) and thermal (nuclear, fossil, concentrated solar power) sources, and to thus enable increased penetration of renewable energy technologies. We take advantage of the enormous fluid and thermal storage capacity of the subsurface to harvest, store, and dispatch energy. Our approach uses permeable geologic formations that are vertically bounded by impermeable layers to constrain pressure and the migration of buoyant CO2 and heated brine. Supercritical CO2 captured from fossil power plants is injected into these formations as a cushion gas to store pressure (bulk energy), provide an heat efficient extraction fluid for efficient power conversion in Brayton Cycle turbines, and generate artesian flow of brine -- which can be used to cool power plants and/or pre-heated (thermal storage) prior to re-injection. Concentric rings of injection and production wells create a hydraulic divide to store pressure, CO2, and thermal energy. The system is pressurized and/or heated when power supply exceeds demand and depressurized when demand exceeds supply. Time-shifting the parasitic loads from pressurizing and injecting brine and CO2 provides bulk energy storage over days to months, whereas time-shifting thermal-energy supply provides dispatchable power and addresses seasonal mismatches between supply and demand. These conditions enable efficient fluid recirculation, heat extraction, power conversion, and add operational flexibility to dispatch electricity. Overall, the system can (a) levelize concentrating solar power, (b) mitigate variability of wind and solar power, (c) reduce water and carbon intensity of energy systems, (d) avoid wasting or curtailing high-capital cost, low-carbon energy resources and (e) allow low-carbon, base-load power to operate at full capacity. This work was performed under the auspices of the U.S. DOE by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344, and has been funded by the U.S. National Science Foundation Sustainable Energy Pathways Program (1230691) and the U.S. Department of Energy Geothermal Technologies Office (DE-FOA-0000336).
Wind-Friendly Flexible Ramping Product Design in Multi-Timescale Power System Operations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Mingjian; Zhang, Jie; Wu, Hongyu
With increasing wind power penetration in the electricity grid, system operators are recognizing the need for additional flexibility, and some are implementing new ramping products as a type of ancillary service. However, wind is generally thought of as causing the need for ramping services, not as being a potential source for the service. In this paper, a multi-timescale unit commitment and economic dispatch model is developed to consider the wind power ramping product (WPRP). An optimized swinging door algorithm with dynamic programming is applied to identify and forecast wind power ramps (WPRs). Designed as positive characteristics of WPRs, the WPRPmore » is then integrated into the multi-timescale dispatch model that considers new objective functions, ramping capacity limits, active power limits, and flexible ramping requirements. Numerical simulations on the modified IEEE 118-bus system show the potential effectiveness of WPRP in increasing the economic efficiency of power system operations with high levels of wind power penetration. It is found that WPRP not only reduces the production cost by using less ramping reserves scheduled by conventional generators, but also possibly enhances the reliability of power system operations. Moreover, wind power forecasts play an important role in providing high-quality WPRP service.« less
Task Decomposition Model for Dispatchers in Dynamic Scheduling of Demand Responsive Transit Systems
DOT National Transportation Integrated Search
2000-06-01
Since the passage of ADA, the demand for paratransit service is steadily increasing. Paratransit companies are relying on computer automation to streamline dispatch operations, increase productivity and reduce operator stress and error. Little resear...
Ro, Young Sun; Shin, Sang Do; Song, Kyoung Jun; Hong, Ki Jeong; Ahn, Ki Ok; Kim, Do Kyun; Kwak, Young Ho
2016-11-01
We studied the effect of a dispatcher-assisted cardiopulmonary resuscitation (CPR) program on paediatric out-of-hospital cardiac arrest (OHCA) outcomes by age groups. All emergency medical services (EMS)-treated paediatric OHCAs in Korea were enrolled between 2012 and 2014, excluding cases witnessed by EMS providers and those with unknown outcomes. The cases were divided into three groups: bystander CPR with dispatcher assistance, bystander CPR without dispatcher assistance, and no-bystander CPR. The endpoint was survival until discharge from hospital. Multivariable logistic regression analysis was performed. The final model with an interaction term was evaluated to compare the effects across age groups. A total of 1529 patients (32.8% bystander CPR with dispatcher assistance, 17.3% without dispatcher assistance, and 54.6% no-bystander CPR) were included. Both bystander CPR groups were more likely to have higher rate of survival to discharge (8.8% and 12.1%) compared to no-bystander CPR (3.9%). The adjusted OR (95% CI) for survival to discharge were 1.77 (1.04-3.00) in bystander CPR with dispatcher assistance and 2.86 (1.61-5.08) in without dispatcher assistance compared with no-bystander CPR. By age groups, the adjusted OR (95% CI) in bystander CPR with and without dispatcher assistance were 2.18 (1.07-4.42) and 2.27 (1.01-5.14) for the group aged 9-18 years; 2.32 (0.64-8.44) and 6.21 (1.83-21.01) for the group aged 1-8 years; 1.06 (0.41-2.77) and 2.00 (0.64-6.18) for the group aged 0-12 months, respectively. Bystander CPR, regardless of dispatcher assistance, was associated with improved survival outcomes after OHCA in the paediatric population. However, the associations between dispatcher-assisted bystander CPR and survival outcomes varied by age. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Kerl, Paul Y; Zhang, Wenxian; Moreno-Cruz, Juan B; Nenes, Athanasios; Realff, Matthew J; Russell, Armistead G; Sokol, Joel; Thomas, Valerie M
2015-09-01
Integrating accurate air quality modeling with decision making is hampered by complex atmospheric physics and chemistry and its coupling with atmospheric transport. Existing approaches to model the physics and chemistry accurately lead to significant computational burdens in computing the response of atmospheric concentrations to changes in emissions profiles. By integrating a reduced form of a fully coupled atmospheric model within a unit commitment optimization model, we allow, for the first time to our knowledge, a fully dynamical approach toward electricity planning that accurately and rapidly minimizes both cost and health impacts. The reduced-form model captures the response of spatially resolved air pollutant concentrations to changes in electricity-generating plant emissions on an hourly basis with accuracy comparable to a comprehensive air quality model. The integrated model allows for the inclusion of human health impacts into cost-based decisions for power plant operation. We use the new capability in a case study of the state of Georgia over the years of 2004-2011, and show that a shift in utilization among existing power plants during selected hourly periods could have provided a health cost savings of $175.9 million dollars for an additional electricity generation cost of $83.6 million in 2007 US dollars (USD2007). The case study illustrates how air pollutant health impacts can be cost-effectively minimized by intelligently modulating power plant operations over multihour periods, without implementing additional emissions control technologies.
Kerl, Paul Y.; Zhang, Wenxian; Moreno-Cruz, Juan B.; Nenes, Athanasios; Realff, Matthew J.; Russell, Armistead G.; Sokol, Joel; Thomas, Valerie M.
2015-01-01
Integrating accurate air quality modeling with decision making is hampered by complex atmospheric physics and chemistry and its coupling with atmospheric transport. Existing approaches to model the physics and chemistry accurately lead to significant computational burdens in computing the response of atmospheric concentrations to changes in emissions profiles. By integrating a reduced form of a fully coupled atmospheric model within a unit commitment optimization model, we allow, for the first time to our knowledge, a fully dynamical approach toward electricity planning that accurately and rapidly minimizes both cost and health impacts. The reduced-form model captures the response of spatially resolved air pollutant concentrations to changes in electricity-generating plant emissions on an hourly basis with accuracy comparable to a comprehensive air quality model. The integrated model allows for the inclusion of human health impacts into cost-based decisions for power plant operation. We use the new capability in a case study of the state of Georgia over the years of 2004–2011, and show that a shift in utilization among existing power plants during selected hourly periods could have provided a health cost savings of $175.9 million dollars for an additional electricity generation cost of $83.6 million in 2007 US dollars (USD2007). The case study illustrates how air pollutant health impacts can be cost-effectively minimized by intelligently modulating power plant operations over multihour periods, without implementing additional emissions control technologies. PMID:26283358
DOE Office of Scientific and Technical Information (OSTI.GOV)
Daniel Curtis; Charles Forsberg; Humberto Garcia
2015-05-01
We propose the development of Nuclear Renewable Oil Shale Systems (NROSS) in northern Europe, China, and the western United States to provide large supplies of flexible, dispatchable, very-low-carbon electricity and fossil fuel production with reduced CO2 emissions. NROSS are a class of large hybrid energy systems in which base-load nuclear reactors provide the primary energy used to produce shale oil from kerogen deposits and simultaneously provide flexible, dispatchable, very-low-carbon electricity to the grid. Kerogen is solid organic matter trapped in sedimentary shale, and large reserves of this resource, called oil shale, are found in northern Europe, China, and the westernmore » United States. NROSS couples electricity generation and transportation fuel production in a single operation, reduces lifecycle carbon emissions from the fuel produced, improves revenue for the nuclear plant, and enables a major shift toward a very-low-carbon electricity grid. NROSS will require a significant development effort in the United States, where kerogen resources have never been developed on a large scale. In Europe, however, nuclear plants have been used for process heat delivery (district heating), and kerogen use is familiar in certain countries. Europe, China, and the United States all have the opportunity to use large scale NROSS development to enable major growth in renewable generation and either substantially reduce or eliminate their dependence on foreign fossil fuel supplies, accelerating their transitions to cleaner, more efficient, and more reliable energy systems.« less
Quantifying the Impacts of Large Scale Integration of Renewables in Indian Power Sector
NASA Astrophysics Data System (ADS)
Kumar, P.; Mishra, T.; Banerjee, R.
2017-12-01
India's power sector is responsible for nearly 37 percent of India's greenhouse gas emissions. For a fast emerging economy like India whose population and energy consumption are poised to rise rapidly in the coming decades, renewable energy can play a vital role in decarbonizing power sector. In this context, India has targeted 33-35 percent emission intensity reduction (with respect to 2005 levels) along with large scale renewable energy targets (100GW solar, 60GW wind, and 10GW biomass energy by 2022) in INDCs submitted at Paris agreement. But large scale integration of renewable energy is a complex process which faces a number of problems like capital intensiveness, matching intermittent loads with least storage capacity and reliability. In this context, this study attempts to assess the technical feasibility of integrating renewables into Indian electricity mix by 2022 and analyze its implications on power sector operations. This study uses TIMES, a bottom up energy optimization model with unit commitment and dispatch features. We model coal and gas fired units discretely with region-wise representation of wind and solar resources. The dispatch features are used for operational analysis of power plant units under ramp rate and minimum generation constraints. The study analyzes India's electricity sector transition for the year 2022 with three scenarios. The base case scenario (no RE addition) along with INDC scenario (with 100GW solar, 60GW wind, 10GW biomass) and low RE scenario (50GW solar, 30GW wind) have been created to analyze the implications of large scale integration of variable renewable energy. The results provide us insights on trade-offs involved in achieving mitigation targets and investment decisions involved. The study also examines operational reliability and flexibility requirements of the system for integrating renewables.
Sample EP Flow Analysis of Severely Damaged Networks
DOE Office of Scientific and Technical Information (OSTI.GOV)
Werley, Kenneth Alan; McCown, Andrew William
These are slides for a presentation at the working group meeting of the WESC SREMP Software Product Integration Team on sample EP flow analysis of severely damaged networks. The following topics are covered: ERCOT EP Transmission Model; Zoomed in to Houston and Overlaying StreetAtlas; EMPACT Solve/Dispatch/Shedding Options; QACS BaseCase Power Flow Solution; 3 Substation Contingency; Gen. & Load/100 Optimal Dispatch; Dispatch Results; Shed Load for Low V; Network Damage Summary; Estimated Service Areas (Potential); Estimated Outage Areas (potential).
Smart Grid | Climate Neutral Research Campuses | NREL
begun to build smart grids. Most operate electricity grids that include power generation; load control plant managers use these communications for energy management and load shedding, which are among the top familiar with equipment interoperability, central dispatch, and load shedding. These are common in smart
Review of Reactive Power Dispatch Strategies for Loss Minimization in a DFIG-based Wind Farm
DOE Office of Scientific and Technical Information (OSTI.GOV)
Zhang, Baohua; Hu, Weihao; Hou, Peng
This study reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and four Wind Turbine (WT) level reactive power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations onmore » a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake model. The results show that the best reactive power dispatch strategy for loss minimization comes when the WF level strategy and WT level control are coordinated and the losses from each device in the WF are considered in the objective.« less
Review of Reactive Power Dispatch Strategies for Loss Minimization in a DFIG-based Wind Farm
Zhang, Baohua; Hu, Weihao; Hou, Peng; ...
2017-06-27
This study reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and four Wind Turbine (WT) level reactive power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations onmore » a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake model. The results show that the best reactive power dispatch strategy for loss minimization comes when the WF level strategy and WT level control are coordinated and the losses from each device in the WF are considered in the objective.« less
NASA Astrophysics Data System (ADS)
Johnson, Timothy Lawrence
2002-09-01
Stabilization of atmospheric greenhouse gas concentrations will likely require significant cuts in electric sector carbon dioxide (CO2) emissions. The ability to capture and sequester CO2 in a manner compatible with today's fossil-fuel based power generating infrastructure offers a potentially low-cost contribution to a larger climate change mitigation strategy. This thesis fills a niche between economy-wide studies of CO 2 abatement and plant-level control technology assessments by examining the contribution that carbon capture and sequestration (CCS) might make toward reducing US electric sector CO2 emissions. The assessment's thirty year perspective ensures that costs sunk in current infrastructure remain relevant and allows time for technological diffusion, but remains free of assumptions about the emergence of unidentified radical innovations. The extent to which CCS might lower CO2 mitigation costs will vary directly with the dispatch of carbon capture plants in actual power-generating systems, and will depend on both the retirement of vintage capacity and competition from abatement alternatives such as coal-to-gas fuel switching and renewable energy sources. This thesis therefore adopts a capacity planning and dispatch model to examine how the current distribution of generating units, natural gas prices, and other industry trends affect the cost of CO2 control via CCS in an actual US electric market. The analysis finds that plants with CO2 capture consistently provide significant reductions in base-load emissions at carbon prices near 100 $/tC, but do not offer an economical means of meeting peak demand unless CO2 reductions in excess of 80 percent are required. Various scenarios estimate the amount by which turn-over of the existing generating infrastructure and the severity of criteria pollutant constraints reduce mitigation costs. A look at CO2 sequestration in the seabed beneath the US Outer Continental Shelf (OCS) complements this model-driven assessment by considering issues of risk, geological storage capacity, and regulation. Extensive experience with offshore oil and gas operations suggests that the technical uncertainties associated with OCS sequestration are not large. The legality of seabed CO 2 disposal under US law and international environmental agreements, however, is ambiguous, and the OCS may be the first region where these regulatory regimes clash over CO2 sequestration.
A thermal storage capacity market for non dispatchable renewable energies
NASA Astrophysics Data System (ADS)
Bennouna, El Ghali; Mouaky, Ammar; Arrad, Mouad; Ghennioui, Abdellatif; Mimet, Abdelaziz
2017-06-01
Due to the increasingly high capacity of wind power and solar PV in Germany and some other European countries and the high share of variable renewable energy resources in comparison to fossil and nuclear capacity, a power reserve market structured by auction systems was created to facilitate the exchange of balance power capacities between systems and even grid operators. Morocco has a large potential for both wind and solar energy and is engaged in a program to deploy 2000MW of wind capacity by 2020 and 3000 MW of solar capacity by 2030. Although the competitiveness of wind energy is very strong, it appears clearly that the wind program could be even more ambitious than what it is, especially when compared to the large exploitable potential. On the other hand, heavy investments on concentrated solar power plants equipped with thermal energy storage have triggered a few years ago including the launching of the first part of the Nour Ouarzazate complex, the goal being to reach stable, dispatchable and affordable electricity especially during evening peak hours. This paper aims to demonstrate the potential of shared thermal storage capacity between dispatchable and non dispatchable renewable energies and particularly CSP and wind power. Thus highlighting the importance of a storage capacity market in parallel to the power reserve market and the and how it could enhance the development of both wind and CSP market penetration.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
The study concerns the Provincial Electricity Authority, a state agency within the Ministry of Interior that supplies electricity to 73 of Thailand`s provinces. The primary objective of this study is to help increase the ability of the Authority to meet the rapidly increasing demand for electric power within the Kingdom of Thailand in a reliable, safe and economic manner. This is Volume 1 and it consists of the following: (1) introduction; (2) assessment; (3) conceptual design; (4) economic and financial evaluation; (5) project plan; (6) Thailand impact; (7) industry review; (8) conclusion; and appendices.
NASA Astrophysics Data System (ADS)
Lesmana, E.; Chaerani, D.; Khansa, H. N.
2018-03-01
Energy-Saving Generation Dispatch (ESGD) is a scheme made by Chinese Government in attempt to minimize CO2 emission produced by power plant. This scheme is made related to global warming which is primarily caused by too much CO2 in earth’s atmosphere, and while the need of electricity is something absolute, the power plants producing it are mostly thermal-power plant which produced many CO2. Many approach to fulfill this scheme has been made, one of them came through Minimum Cost Flow in which resulted in a Quadratically Constrained Quadratic Programming (QCQP) form. In this paper, ESGD problem with Minimum Cost Flow in QCQP form will be solved using Lagrange’s Multiplier Method
Defense Threat Reduction Agency > Research > DTRIAC > DTRIAC Dispatch
@mail.mil with your submissions. DTRIAC Dispatch - Vol 5, Issue 3 DTRIAC Dispatch - Vol 5, Issue 2 DTRIAC Dispatch - Vol 5, Issue 1 DTRIAC Dispatch - Vol 4, Issue 1 DTRIAC Dispatch - Vol 3, Issue 4 DTRIAC Dispatch - Vol 3, Issue 3 DTRIAC Dispatch - Vol 3, Issue 2 DTRIAC Dispatch - Vol 3, Issue 1 DTRIAC Dispatch - Vol
Energy storage deployment and innovation for the clean energy transition
NASA Astrophysics Data System (ADS)
Kittner, Noah; Lill, Felix; Kammen, Daniel M.
2017-09-01
The clean energy transition requires a co-evolution of innovation, investment, and deployment strategies for emerging energy storage technologies. A deeply decarbonized energy system research platform needs materials science advances in battery technology to overcome the intermittency challenges of wind and solar electricity. Simultaneously, policies designed to build market growth and innovation in battery storage may complement cost reductions across a suite of clean energy technologies. Further integration of R&D and deployment of new storage technologies paves a clear route toward cost-effective low-carbon electricity. Here we analyse deployment and innovation using a two-factor model that integrates the value of investment in materials innovation and technology deployment over time from an empirical dataset covering battery storage technology. Complementary advances in battery storage are of utmost importance to decarbonization alongside improvements in renewable electricity sources. We find and chart a viable path to dispatchable US$1 W-1 solar with US$100 kWh-1 battery storage that enables combinations of solar, wind, and storage to compete directly with fossil-based electricity options.
Real-time pricing strategy of micro-grid energy centre considering price-based demand response
NASA Astrophysics Data System (ADS)
Xu, Zhiheng; Zhang, Yongjun; Wang, Gan
2017-07-01
With the development of energy conversion technology such as power to gas (P2G), fuel cell and so on, the coupling between energy sources becomes more and more closely. Centralized dispatch among electricity, natural gas and heat will become a trend. With the goal of maximizing the system revenue, this paper establishes the model of micro-grid energy centre based on energy hub. According to the proposed model, the real-time pricing strategy taking into account price-based demand response of load is developed. And the influence of real-time pricing strategy on the peak load shifting is discussed. In addition, the impact of wind power predicted inaccuracy on real-time pricing strategy is analysed.
Cloud computing for energy management in smart grid - an application survey
NASA Astrophysics Data System (ADS)
Naveen, P.; Kiing Ing, Wong; Kobina Danquah, Michael; Sidhu, Amandeep S.; Abu-Siada, Ahmed
2016-03-01
The smart grid is the emerging energy system wherein the application of information technology, tools and techniques that make the grid run more efficiently. It possesses demand response capacity to help balance electrical consumption with supply. The challenges and opportunities of emerging and future smart grids can be addressed by cloud computing. To focus on these requirements, we provide an in-depth survey on different cloud computing applications for energy management in the smart grid architecture. In this survey, we present an outline of the current state of research on smart grid development. We also propose a model of cloud based economic power dispatch for smart grid.
Jihong, Qu
2014-01-01
Wind-hydrothermal power system dispatching has received intensive attention in recent years because it can help develop various reasonable plans to schedule the power generation efficiency. But future data such as wind power output and power load would not be accurately predicted and the nonlinear nature involved in the complex multiobjective scheduling model; therefore, to achieve accurate solution to such complex problem is a very difficult task. This paper presents an interval programming model with 2-step optimization algorithm to solve multiobjective dispatching. Initially, we represented the future data into interval numbers and simplified the object function to a linear programming problem to search the feasible and preliminary solutions to construct the Pareto set. Then the simulated annealing method was used to search the optimal solution of initial model. Thorough experimental results suggest that the proposed method performed reasonably well in terms of both operating efficiency and precision. PMID:24895663
Ren, Kun; Jihong, Qu
2014-01-01
Wind-hydrothermal power system dispatching has received intensive attention in recent years because it can help develop various reasonable plans to schedule the power generation efficiency. But future data such as wind power output and power load would not be accurately predicted and the nonlinear nature involved in the complex multiobjective scheduling model; therefore, to achieve accurate solution to such complex problem is a very difficult task. This paper presents an interval programming model with 2-step optimization algorithm to solve multiobjective dispatching. Initially, we represented the future data into interval numbers and simplified the object function to a linear programming problem to search the feasible and preliminary solutions to construct the Pareto set. Then the simulated annealing method was used to search the optimal solution of initial model. Thorough experimental results suggest that the proposed method performed reasonably well in terms of both operating efficiency and precision.
Data centers as dispatchable loads to harness stranded power
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kim, Kibaek; Yang, Fan; Zavala, Victor M.
Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast,more » optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.« less
Data centers as dispatchable loads to harness stranded power
Kim, Kibaek; Yang, Fan; Zavala, Victor M.; ...
2016-07-20
Here, we analyze how traditional data center placement and optimal placement of dispatchable data centers affect power grid efficiency. We use detailed network models, stochastic optimization formulations, and diverse renewable generation scenarios to perform our analysis. Our results reveal that significant spillage and stranded power will persist in power grids as wind power levels are increased. A counter-intuitive finding is that collocating data centers with inflexible loads next to wind farms has limited impacts on renewable portfolio standard (RPS) goals because it provides limited system-level flexibility. Such an approach can, in fact, increase stranded power and fossil-fueled generation. In contrast,more » optimally placing data centers that are dispatchable provides system-wide flexibility, reduces stranded power, and improves efficiency. In short, optimally placed dispatchable computing loads can enable better scaling to high RPS. In our case study, we find that these dispatchable computing loads are powered to 60-80% of their requested capacity, indicating that there are significant economic incentives provided by stranded power.« less
Krueger, Ute; Schimmelpfeng, Katja
2013-03-01
A sufficient staffing level in fire and rescue dispatch centers is crucial for saving lives. Therefore, it is important to estimate the expected workload properly. For this purpose, we analyzed whether a dispatch center can be considered as a call center. Current call center publications very often model call arrivals as a non-homogeneous Poisson process. This bases on the underlying assumption of the caller's independent decision to call or not to call. In case of an emergency, however, there are often calls from more than one person reporting the same incident and thus, these calls are not independent. Therefore, this paper focuses on the dependency of calls in a fire and rescue dispatch center. We analyzed and evaluated several distributions in this setting. Results are illustrated using real-world data collected from a typical German dispatch center in Cottbus ("Leitstelle Lausitz"). We identified the Pólya distribution as being superior to the Poisson distribution in describing the call arrival rate and the Weibull distribution to be more suitable than the exponential distribution for interarrival times and service times. However, the commonly used distributions offer acceptable approximations. This is important for estimating a sufficient staffing level in practice using, e.g., the Erlang-C model.
Code of Federal Regulations, 2013 CFR
2013-10-01
... dispatch means, by the use of an electrical or mechanical device— (i) To control the movement of a train or.... Movement of a train means the movement of one or more locomotives coupled with or without cars, requiring... operations or where the operation is that of classifying and assembling rail cars within a railroad yard for...
Code of Federal Regulations, 2014 CFR
2014-10-01
... dispatch means, by the use of an electrical or mechanical device— (i) To control the movement of a train or.... Movement of a train means the movement of one or more locomotives coupled with or without cars, requiring... operations or where the operation is that of classifying and assembling rail cars within a railroad yard for...
Code of Federal Regulations, 2012 CFR
2012-10-01
... dispatch means, by the use of an electrical or mechanical device— (i) To control the movement of a train or.... Movement of a train means the movement of one or more locomotives coupled with or without cars, requiring... operations or where the operation is that of classifying and assembling rail cars within a railroad yard for...
Code of Federal Regulations, 2010 CFR
2010-10-01
... dispatch means, by the use of an electrical or mechanical device— (i) To control the movement of a train or.... Movement of a train means the movement of one or more locomotives coupled with or without cars, requiring... operations or where the operation is that of classifying and assembling rail cars within a railroad yard for...
Code of Federal Regulations, 2011 CFR
2011-10-01
... dispatch means, by the use of an electrical or mechanical device— (i) To control the movement of a train or.... Movement of a train means the movement of one or more locomotives coupled with or without cars, requiring... operations or where the operation is that of classifying and assembling rail cars within a railroad yard for...
NASA Astrophysics Data System (ADS)
Meng, M.; Macknick, J.; Tidwell, V. C.; Zagona, E. A.; Magee, T. M.; Bennett, K.; Middleton, R. S.
2017-12-01
The U.S. electricity sector depends on large amounts of water for hydropower generation and cooling thermoelectric power plants. Variability in water quantity and temperature due to climate change could reduce the performance and reliability of individual power plants and of the electric grid as a system. While studies have modeled water usage in power systems planning, few have linked grid operations with physical water constraints or with climate-induced changes in water resources to capture the role of the energy-water nexus in power systems flexibility and adequacy. In addition, many hydrologic and hydropower models have a limited representation of power sector water demands and grid interaction opportunities of demand response and ancillary services. A multi-model framework was developed to integrate and harmonize electricity, water, and climate models, allowing for high-resolution simulation of the spatial, temporal, and physical dynamics of these interacting systems. The San Juan River basin in the Southwestern U.S., which contains thermoelectric power plants, hydropower facilities, and multiple non-energy water demands, was chosen as a case study. Downscaled data from three global climate models and predicted regional water demand changes were implemented in the simulations. The Variable Infiltration Capacity hydrologic model was used to project inflows, ambient air temperature, and humidity in the San Juan River Basin. Resulting river operations, water deliveries, water shortage sharing agreements, new water demands, and hydroelectricity generation at the basin-scale were estimated with RiverWare. The impacts of water availability and temperature on electric grid dispatch, curtailment, cooling water usage, and electricity generation cost were modeled in PLEXOS. Lack of water availability resulting from climate, new water demands, and shortage sharing agreements will require thermoelectric generators to drastically decrease power production, as much as 50% during intensifying drought scenarios, which can have broader electricity sector system implications. Results relevant to stakeholder and power provider interests highlight the vulnerabilities in grid operations driven by water shortage agreements and changes in the climate.
NASA Astrophysics Data System (ADS)
Veselka, T. D.; Poch, L.
2011-12-01
Integrating high penetration levels of wind and solar energy resources into the power grid is a formidable challenge in virtually all interconnected systems due to the fact that supply and demand must remain in balance at all times. Since large scale electricity storage is currently not economically viable, generation must exactly match electricity demand plus energy losses in the system as time unfolds. Therefore, as generation from variable resources such as wind and solar fluctuate, production from generating resources that are easier to control and dispatch need to compensate for these fluctuations while at the same time respond to both instantaneous change in load and follow daily load profiles. The grid in the Western U.S. is not exempt to grid integration challenges associated with variable resources. However, one advantage that the power system in the Western U.S. has over many other regional power systems is that its footprint contains an abundance of hydropower resources. Hydropower plants, especially those that have reservoir water storage, can physically change electricity production levels very quickly both via a dispatcher and through automatic generation control. Since hydropower response time is typically much faster than other dispatchable resources such as steam or gas turbines, it is well suited to alleviate variable resource grid integration issues. However, despite an abundance of hydropower resources and the current low penetration of variable resources in the Western U.S., problems have already surfaced. This spring in the Pacific Northwest, wetter than normal hydropower conditions in combination with transmission constraints resulted in controversial wind resource shedding. This action was taken since water spilling would have increased dissolved oxygen levels downstream of dams thereby significantly degrading fish habitats. The extent to which hydropower resources will be able to contribute toward a stable and reliable Western grid is currently being studied. Typically these studies consider the inherent flexibility of hydropower technologies, but tend to fall short on details regarding grid operations, institutional arrangements, and hydropower environmental regulations. This presentation will focus on an analysis that Argonne National Laboratory is conducting in collaboration with the Western Area Power Administration (Western). The analysis evaluates the extent to which Western's hydropower resources may help with grid integration challenges via a proposed Energy Imbalance Market. This market encompasses most of the Western Electricity Coordinating Council footprint. It changes grid operations such that the real-time dispatch would be, in part, based on a 5-minute electricity market. The analysis includes many factors such as site-specific environmental considerations at each of its hydropower facilities, long-term firm purchase agreements, and hydropower operating objectives and goals. Results of the analysis indicate that site-specific details significantly affect the ability of hydropower plant to respond to grid needs in a future which will have a high penetration of variable resources.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpkins, Travis; Cutler, Dylan; Hirsch, Brian
There are thousands of isolated, diesel-powered microgrids that deliver energy to remote communities around the world at very high energy costs. The Remote Communities Renewable Energy program aims to help these communities reduce their fuel consumption and lower their energy costs through the use of high penetration renewable energy. As part of this program, the REopt modeling platform for energy system integration and optimization was used to analyze cost-optimal pathways toward achieving a combined 75% reduction in diesel fuel and fuel oil consumption in a select Alaskan village. In addition to the existing diesel generator and fuel oil heating technologies,more » the model was able to select from among wind, battery storage, and dispatchable electric heaters to meet the electrical and thermal loads. The model results indicate that while 75% fuel reduction appears to be technically feasible it may not be economically viable at this time. When the fuel reduction target was relaxed, the results indicate that by installing high-penetration renewable energy, the community could lower their energy costs by 21% while still reducing their fuel consumption by 54%.« less
Residential Solar PV Systems in the Carolinas: Opportunities and Outcomes.
Alqahtani, Bandar Jubran; Holt, Kyra Moore; Patiño-Echeverri, Dalia; Pratson, Lincoln
2016-02-16
This paper presents a first-order analysis of the feasibility and technical, environmental, and economic effects of large levels of solar photovoltaic (PV) penetration within the services areas of the Duke Energy Carolinas (DEC) and Duke Energy Progress (DEP). A PV production model based on household density and a gridded hourly global horizontal irradiance data set simulates hourly PV power output from roof-top installations, while a unit commitment and real-time economic dispatch (UC-ED) model simulates hourly system operations. We find that the large generating capacity of base-load nuclear power plants (NPPs) without ramping capability in the region limits PV integration levels to 5.3% (6510 MW) of 2015 generation. Enabling ramping capability for NPPs would raise the limit of PV penetration to near 9% of electricity generated. If the planned retirement of coal-fired power plants together with new installations and upgrades of natural gas and nuclear plants materialize in 2025, and if NPPs operate flexibly, then the share of coal-fired electricity will be reduced from 37% to 22%. A 9% penetration of electricity from PV would further reduce the share of coal-fired electricity by 4-6% resulting in a system-wide CO2 emissions rate of 0.33 to 0.40 tons/MWh and associated abatement costs of 225-415 (2015$ per ton).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Papalexopoulos, A.; Hansen, C.; Perrino, D.
This project examined the impact of renewable energy sources, which have zero incremental energy costs, on the sustainability of conventional generation. This “missing money” problem refers to market outcomes in which infra-marginal energy revenues in excess of operations and maintenance (O&M) costs are systematically lower than the amortized costs of new entry for a marginal generator. The problem is caused by two related factors: (1) conventional generation is dispatched less, and (2) the price that conventional generation receives for its energy is lower. This lower revenue stream may not be sufficient to cover both the variable and fixed costs ofmore » conventional generation. In fact, this study showed that higher wind penetrations in the Electric Reliability Council of Texas (ERCOT) system could cause many conventional generators to become uneconomic.« less
Automated power management and control
NASA Technical Reports Server (NTRS)
Dolce, James L.
1991-01-01
A comprehensive automation design is being developed for Space Station Freedom's electric power system. A joint effort between NASA's Office of Aeronautics and Exploration Technology and NASA's Office of Space Station Freedom, it strives to increase station productivity by applying expert systems and conventional algorithms to automate power system operation. The initial station operation will use ground-based dispatches to perform the necessary command and control tasks. These tasks constitute planning and decision-making activities that strive to eliminate unplanned outages. We perceive an opportunity to help these dispatchers make fast and consistent on-line decisions by automating three key tasks: failure detection and diagnosis, resource scheduling, and security analysis. Expert systems will be used for the diagnostics and for the security analysis; conventional algorithms will be used for the resource scheduling.
Electric power grid control using a market-based resource allocation system
Chassin, David P
2014-01-28
Disclosed herein are representative embodiments of methods, apparatus, and systems for distributing a resource (such as electricity) using a resource allocation system. In one exemplary embodiment, a plurality of requests for electricity are received from a plurality of end-use consumers. The requests indicate a requested quantity of electricity and a consumer-requested index value indicative of a maximum price a respective end-use consumer will pay for the requested quantity of electricity. A plurality of offers for supplying electricity are received from a plurality of resource suppliers. The offers indicate an offered quantity of electricity and a supplier-requested index value indicative of a minimum price for which a respective supplier will produce the offered quantity of electricity. A dispatched index value is computed at which electricity is to be supplied based at least in part on the consumer-requested index values and the supplier-requested index values.
Electric power grid control using a market-based resource allocation system
Chassin, David P.
2015-07-21
Disclosed herein are representative embodiments of methods, apparatus, and systems for distributing a resource (such as electricity) using a resource allocation system. In one exemplary embodiment, a plurality of requests for electricity are received from a plurality of end-use consumers. The requests indicate a requested quantity of electricity and a consumer-requested index value indicative of a maximum price a respective end-use consumer will pay for the requested quantity of electricity. A plurality of offers for supplying electricity are received from a plurality of resource suppliers. The offers indicate an offered quantity of electricity and a supplier-requested index value indicative of a minimum price for which a respective supplier will produce the offered quantity of electricity. A dispatched index value is computed at which electricity is to be supplied based at least in part on the consumer-requested index values and the supplier-requested index values.
DOT National Transportation Integrated Search
2010-09-01
Traffic congestion is a primary concern during major incident and evacuation scenarios and can create difficulties for emergency vehicles attempting to enter and exit affected areas; however, many of the dispatchers who would be responsible for direc...
Feasibility of a computer-assisted feedback system between dispatch centre and ambulances.
Lindström, Veronica; Karlsten, Rolf; Falk, Ann-Charlotte; Castrèn, Maaret
2011-06-01
The aim of the study was to evaluate the feasibility of a newly developed computer-assisted feedback system between dispatch centre and ambulances in Stockholm, Sweden. A computer-assisted feedback system based on a Finnish model was designed to fit the Swedish emergency medical system. Feedback codes were identified and divided into three categories; assessment of patients' primary condition when ambulance arrives at scene, no transport by the ambulance and level of priority. Two ambulances and one emergency medical communication centre (EMCC) in Stockholm participated in the study. A sample of 530 feedback codes sent through the computer-assisted feedback system was reviewed. The information on the ambulance medical records was compared with the feedback codes used and 240 assignments were further analyzed. The used feedback codes sent from ambulance to EMCC were correct in 92% of the assignments. The most commonly used feedback code sent to the emergency medical dispatchers was 'agree with the dispatchers' assessment'. In addition, in 160 assignments there was a mismatch between emergency medical dispatchers and ambulance nurse assessments. Our results have shown a high agreement between medical dispatchers and ambulance nurse assessment. The feasibility of the feedback codes seems to be acceptable based on the small margin of error. The computer-assisted feedback system may, when used on a daily basis, make it possible for the medical dispatchers to receive feedback in a structural way. The EMCC organization can directly evaluate any changes in the assessment protocol by structured feedback sent from the ambulance.
NASA Astrophysics Data System (ADS)
Bowen, Brian Hugh
1998-12-01
Electricity utilities in the Southern African region are conscious that gains could be made from more economically efficient trading but have had no tools with which to analyze the effects of a change in policy. This research is the first to provide transparent quantitative techniques to quantify the impacts of new trading arrangements in this region. The study poses a model of the recently formed Southern African Power Pool, built with the collaboration of the region's national utilities to represent each country's demand and generation/transmission system. The multi-region model includes commitment and dispatch from diverse hydrothermal sources over a vast area. Economic gains are determined by comparing the total costs under free-trade conditions with those from the existing fixed-trade bilateral arrangements. The objective function minimizes production costs needed to meet total demand, subject to each utility's constraints for thermal and hydro generation, transmission, load balance and losses. Linearized thermal cost functions are used along with linearized input output hydropower plant curves and hydrothermal on/off status variables to formulate a mixed-integer programming problem. Results from the modeling show that moving to optimal trading patterns could save between 70 million and 130 million per year. With free-trade policies the quantity of power flow between utilities is doubled and maximum usage is made of the hydropower stations thus reducing costs and fuel use. In electricity exporting countries such as Zambia and Mozambique gains from increased trade are achieved which equal 16% and 18% respectively of the value of their total manufactured exports. A sensitivity analysis is conducted on the possible effects of derating generation, derating transmission and reducing water inflows but gains remain large. Maximum economic gains from optimal trading patterns can be achieved by each country allowing centralized control through the newly founded SAPP coordination center. Using standard mixed integer programming solvers makes the cost of such modeling activity easily affordable to each utility in the Southern African pool. This research provides the utilities with the modeling tools to quantify the gains from increased trade and thereby furthers a move towards greater efficiency, faster economic growth and reduced use of fossil fuels.
A framework for analyzing the impact of data integrity/quality on electricity market operations
NASA Astrophysics Data System (ADS)
Choi, Dae Hyun
This dissertation examines the impact of data integrity/quality in the supervisory control and data acquisition (SCADA) system on real-time locational marginal price (LMP) in electricity market operations. Measurement noise and/or manipulated sensor errors in a SCADA system may mislead system operators about real-time conditions in a power system, which, in turn, may impact the price signals in real-time power markets. This dissertation serves as a first attempt to analytically investigate the impact of bad/malicious data on electric power market operations. In future power system operations, which will probably involve many more sensors, the impact of sensor data integrity/quality on grid operations will become increasingly important. The first part of this dissertation studies from a market participant's perspective a new class of malicious data attacks on state estimation, which subsequently influences the result of the newly emerging look-ahead dispatch models in the real-time power market. In comparison with prior work of cyber-attack on static dispatch where no inter-temporal ramping constraint is considered, we propose a novel attack strategy, named ramp-induced data (RID) attack, with which the attacker can manipulate the limits of ramp constraints of generators in look-ahead dispatch. It is demonstrated that the proposed attack can lead to financial profits via malicious capacity withholding of selected generators, while being undetected by the existing bad data detection algorithm embedded in today's state estimation software. In the second part, we investigate from a system operator's perspective the sensitivity of locational marginal price (LMP) with respect to data corruption-induced state estimation error in real-time power market. Two data corruption scenarios are considered, in which corrupted continuous data (e.g., the power injection/flow and voltage magnitude) falsify power flow estimate whereas corrupted discrete data (e.g., the on/off status of a circuit breaker) do network topology estimate, thus leading to the distortion of LMP. We present an analytical framework to quantify real-time LMP sensitivity subject to continuous and discrete data corruption via state estimation. The proposed framework offers system operators an analytical tool to identify economically sensitive buses and transmission lines to data corruption as well as find sensors that impact LMP changes significantly. This dissertation serves as a first step towards rigorous understanding of the fundamental coupling among cyber, physical and economical layers of operations in future smart grid.
Operation and planning of coordinated natural gas and electricity infrastructures
NASA Astrophysics Data System (ADS)
Zhang, Xiaping
Natural gas is becoming rapidly the optimal choice for fueling new generating units in electric power system driven by abundant natural gas supplies and environmental regulations that are expected to cause coal-fired generation retirements. The growing reliance on natural gas as a dominant fuel for electricity generation throughout North America has brought the interaction between the natural gas and power grids into sharp focus. The primary concern and motivation of this research is to address the emerging interdependency issues faced by the electric power and natural gas industry. This thesis provides a comprehensive analysis of the interactions between the two systems regarding the short-term operation and long-term infrastructure planning. Natural gas and renewable energy appear complementary in many respects regarding fuel price and availability, environmental impact, resource distribution and dispatchability. In addition, demand response has also held the promise of making a significant contribution to enhance system operations by providing incentives to customers for a more flat load profile. We investigated the coordination between natural gas-fired generation and prevailing nontraditional resources including renewable energy, demand response so as to provide economical options for optimizing the short-term scheduling with the intense natural gas delivery constraints. As the amount and dispatch of gas-fired generation increases, the long-term interdependency issue is whether there is adequate pipeline capacity to provide sufficient gas to natural gas-fired generation during the entire planning horizon while it is widely used outside the power sector. This thesis developed a co-optimization planning model by incorporating the natural gas transportation system into the multi-year resource and transmission system planning problem. This consideration would provide a more comprehensive decision for the investment and accurate assessment for system adequacy and reliability. With the growing reliance on natural gas and widespread utilization of highly efficient combined heat and power (CHP), it is also questionable that whether the independent design of infrastructures can meet potential challenges of future energy supply. To address this issue, this thesis proposed an optimization framework for a sustainable multiple energy system expansion planning based on an energy hub model while considering the energy efficiency, emission and reliability performance. In addition, we introduced the probabilistic reliability evaluation and flow network analysis into the multiple energy system design in order to obtain an optimal and reliable network topology.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roy, L.; Rao, N.D.
1983-04-01
This paper presents a new method for optimal dispatch of real and reactive power generation which is based on cartesian coordinate formulation of economic dispatch problem and reclassification of state and control variables associated with generator buses. The voltage and power at these buses are classified as parametric and functional inequality constraints, and are handled by reduced gradient technique and penalty factor approach respectively. The advantage of this classification is the reduction in the size of the equality constraint model, leading to less storage requirement. The rectangular coordinate formulation results in an exact equality constraint model in which the coefficientmore » matrix is real, sparse, diagonally dominant, smaller in size and need be computed and factorized once only in each gradient step. In addition, Lagragian multipliers are calculated using a new efficient procedure. A natural outcome of these features is the solution of the economic dispatch problem, faster than other methods available to date in the literature. Rapid and reliable convergence is an additional desirable characteristic of the method. Digital simulation results are presented on several IEEE test systems to illustrate the range of application of the method visa-vis the popular Dommel-Tinney (DT) procedure. It is found that the proposed method is more reliable, 3-4 times faster and requires 20-30 percent less storage compared to the DT algorithm, while being just as general. Thus, owing to its exactness, robust mathematical model and less computational requirements, the method developed in the paper is shown to be a practically feasible algorithm for on-line optimal power dispatch.« less
Using one-way communications in a market-based resource allocation system
Chassin, David P.; Pratt, Robert G.
2014-07-22
Disclosed herein are representative embodiments of methods, apparatus, and systems for distributing a resource (such as electricity) using a resource allocation system. In one exemplary embodiment, a plurality of requests for electricity are received from a plurality of end-use consumers. The requests indicate a requested quantity of electricity and a consumer-requested index value indicative of a maximum price a respective end-use consumer will pay for the requested quantity of electricity. A plurality of offers for supplying electricity are received from a plurality of resource suppliers. The offers indicate an offered quantity of electricity and a supplier-requested index value indicative of a minimum price for which a respective supplier will produce the offered quantity of electricity. A dispatched index value is computed at which electricity is to be supplied based at least in part on the consumer-requested index values and the supplier-requested index values.
Using bi-directional communications in a market-based resource allocation system
Chassin, David P; Pratt, Robert G
2014-04-01
Disclosed herein are representative embodiments of methods, apparatus, and systems for distributing a resource (such as electricity) using a resource allocation system. In one exemplary embodiment, a plurality of requests for electricity are received from a plurality of end-use consumers. The requests indicate a requested quantity of electricity and a consumer-requested index value indicative of a maximum price a respective end-use consumer will pay for the requested quantity of electricity. A plurality of offers for supplying electricity are received from a plurality of resource suppliers. The offers indicate an offered quantity of electricity and a supplier-requested index value indicative of a minimum price for which a respective supplier will produce the offered quantity of electricity. A dispatched index value is computed at which electricity is to be supplied based at least in part on the consumer-requested index values and the supplier-requested index values.
Using bi-directional communications in a market-based resource allocation system
Chassin, David P.; Pratt, Robert G.
2015-09-08
Disclosed herein are representative embodiments of methods, apparatus, and systems for distributing a resource (such as electricity) using a resource allocation system. In one exemplary embodiment, a plurality of requests for electricity are received from a plurality of end-use consumers. The requests indicate a requested quantity of electricity and a consumer-requested index value indicative of a maximum price a respective end-use consumer will pay for the requested quantity of electricity. A plurality of offers for supplying electricity are received from a plurality of resource suppliers. The offers indicate an offered quantity of electricity and a supplier-requested index value indicative of a minimum price for which a respective supplier will produce the offered quantity of electricity. A dispatched index value is computed at which electricity is to be supplied based at least in part on the consumer-requested index values and the supplier-requested index values.
Using bi-directional communications in a market-based resource allocation system
Chassin, David P; Pratt, Robert G
2015-05-05
Disclosed herein are representative embodiments of methods, apparatus, and systems for distributing a resource (such as electricity) using a resource allocation system. In one exemplary embodiment, a plurality of requests for electricity are received from a plurality of end-use consumers. The requests indicate a requested quantity of electricity and a consumer-requested index value indicative of a maximum price a respective end-use consumer will pay for the requested quantity of electricity. A plurality of offers for supplying electricity are received from a plurality of resource suppliers. The offers indicate an offered quantity of electricity and a supplier-requested index value indicative of a minimum price for which a respective supplier will produce the offered quantity of electricity. A dispatched index value is computed at which electricity is to be supplied based at least in part on the consumer-requested index values and the supplier-requested index values.
[Justifying measures to correct functional state of operators varying in personal anxiety].
2012-01-01
Workers of operating and dispatching occupations are exposed to high nervous and emotional exertion that result in increased personal anxiety, working stress and overstrain. That requires physiologically justified correction of hazardous psycho-physiologic states via various prophylactic measures (stay in schungite room, autogenous training, central electric analgesia, electric acupuncture). Attempted relaxation sessions in schungite room revealed in highly anxious individuals an increased velocity of visual signals perception, of attention concentration and shifting. Autogenous training sessions improve memory and have significant hypotensive effect in highly anxious individuals.
Forecasting Electricity Prices in an Optimization Hydrothermal Problem
NASA Astrophysics Data System (ADS)
Matías, J. M.; Bayón, L.; Suárez, P.; Argüelles, A.; Taboada, J.
2007-12-01
This paper presents an economic dispatch algorithm in a hydrothermal system within the framework of a competitive and deregulated electricity market. The optimization problem of one firm is described, whose objective function can be defined as its profit maximization. Since next-day price forecasting is an aspect crucial, this paper proposes an efficient yet highly accurate next-day price new forecasting method using a functional time series approach trying to exploit the daily seasonal structure of the series of prices. For the optimization problem, an optimal control technique is applied and Pontryagin's theorem is employed.
Automating security monitoring and analysis for Space Station Freedom's electric power system
NASA Technical Reports Server (NTRS)
Dolce, James L.; Sobajic, Dejan J.; Pao, Yoh-Han
1990-01-01
Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A new approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.
Automating security monitoring and analysis for Space Station Freedom's electric power system
NASA Technical Reports Server (NTRS)
Dolce, James L.; Sobajic, Dejan J.; Pao, Yoh-Han
1990-01-01
Operating a large, space power system requires classifying the system's status and analyzing its security. Conventional algorithms are used by terrestrial electric utilities to provide such information to their dispatchers, but their application aboard Space Station Freedom will consume too much processing time. A novel approach for monitoring and analysis using adaptive pattern techniques is presented. This approach yields an on-line security monitoring and analysis algorithm that is accurate and fast; and thus, it can free the Space Station Freedom's power control computers for other tasks.
Modeling and Economic Analysis of Power Grid Operations in a Water Constrained System
NASA Astrophysics Data System (ADS)
Zhou, Z.; Xia, Y.; Veselka, T.; Yan, E.; Betrie, G.; Qiu, F.
2016-12-01
The power sector is the largest water user in the United States. Depending on the cooling technology employed at a facility, steam-electric power stations withdrawal and consume large amounts of water for each megawatt hour of electricity generated. The amounts are dependent on many factors, including ambient air and water temperatures, cooling technology, etc. Water demands from most economic sectors are typically highest during summertime. For most systems, this coincides with peak electricity demand and consequently a high demand for thermal power plant cooling water. Supplies however are sometimes limited due to seasonal precipitation fluctuations including sporadic droughts that lead to water scarcity. When this occurs there is an impact on both unit commitments and the real-time dispatch. In this work, we model the cooling efficiency of several different types of thermal power generation technologies as a function of power output level and daily temperature profiles. Unit specific relationships are then integrated in a power grid operational model that minimizes total grid production cost while reliably meeting hourly loads. Grid operation is subject to power plant physical constraints, transmission limitations, water availability and environmental constraints such as power plant water exit temperature limits. The model is applied to a standard IEEE-118 bus system under various water availability scenarios. Results show that water availability has a significant impact on power grid economics.
Cybersecurity Awareness in the Power Grid
DOE Office of Scientific and Technical Information (OSTI.GOV)
Scholtz, Jean; Franklin, Lyndsey; Le Blanc, Katya L.
2016-07-10
We report on a series of interviews and observations conducted with control room dispatchers in a bulk electrical system. These dispatchers must react quickly to incidents as they happen in order to ensure the reliability and safe operation of the power grid. They do not have the time to evaluate incidents for signs of cyber-attack as part of their initial response. Cyber-attack detection involves multiple personnel from a variety of roles at both local and regional levels. Smart grid technology will improve detection and defense capabilities of the future grid, however, the current infrastructure remains a mixture of old andmore » new equipment which will continue to operate for some time. Thus, research still needs to focus on strategies for the detection of malicious activity on current infrastructure as well as protection and remediation.« less
Technical assistance for law-enforcement communications: Case study report two
NASA Technical Reports Server (NTRS)
Reilly, N. B.; Mustain, J. A.
1979-01-01
Two case histories are presented. In one study the feasibility of consolidating dispatch center operations for small agencies is considered. System load measurements were taken and queueing analysis applied to determine numbers of personnel required for each separate agency and for a consolidated dispatch center. Functional requirements were developed and a cost model was designed to compare relative costs of various alternatives including continuation of the present system, consolidation of a manual system, and consolidated computer-aided dispatching. The second case history deals with the consideration of a multi-regional, intrastate radio frequency for improved interregional communications. Sample standards and specifications for radio equipment are provided.
Cancellations of (helicopter-transported) mobile medical team dispatches in the Netherlands.
Giannakopoulos, Georgios F; Lubbers, Wouter D; Christiaans, Herman M T; van Exter, Pieternel; Bet, Piet; Hugen, Paul J C; Innemee, Gerard; Schubert, Edo; de Lange-Klerk, Elly S M; Goslings, J Carel; Jukema, Gerrolt N
2010-08-01
The trauma centre of the Trauma Center Region North-West Netherlands (TRNWN) has consensus criteria for Mobile Medical Team (MMT) scene dispatch. The MMT can be dispatched by the EMS-dispatch centre or by the on-scene ambulance crew and is transported by helicopter or ground transport. Although much attention has been paid to improve the dispatch criteria, the MMT is often cancelled after being dispatched. The aim of this study was to assess the cancellation rate and the noncompliant dispatches of our MMT and to identify factors associated with this form of primary overtriage. By retrospective analysis of all MMT dispatches in the period from 1 July 2006 till 31 December 2006 using chart review, we conducted a consecutive case review of 605 dispatches. Four hundred and sixty seven of these were included for our study, collecting data related to prehospital triage, patient's condition on-scene and hospital course. Average age was 35.9 years; the majority of the patients were male (65.3%). Four hundred and thirty patients were victims of trauma, sustaining injuries in most cases from blunt trauma (89.3%). After being dispatched, the MMT was cancelled 203 times (43.5%). Statistically significant differences between assists and cancellations were found for overall mortality, mean RTS, GCS and ISS, mean hospitalization, length and amount of ICU admissions (p < 0.001). All dispatches were evaluated by using the MMT-dispatch criteria and mission appropriateness criteria. Almost 26% of all dispatches were neither appropriate, nor met the dispatch criteria. Fourteen missions were appropriate, but did not meet the dispatch criteria. The remaining 318 dispatches had met the dispatch criteria, of which 135 (30.3%) were also appropriate. The calculated additional costs of the cancelled dispatches summed up to a total of 34,448 euro, amounting to 2.2% of the total MMT costs during the study period. In our trauma system, the MMT dispatches are involved with high rates of overtriage. After being dispatched, the MMT is cancelled in almost 50% of all cases. We found an undertriage rate of 4%, which we think is acceptable. All cancellations were justified. The additional costs of the cancelled missions were within an acceptable range. According to this study, it seems to be possible to reduce the overtriage rate of the MMT dispatches, without increasing the undertriage rate to non-acceptable levels.
Electrical and chemical interactions at Mars Workshop, part 1
NASA Technical Reports Server (NTRS)
1992-01-01
The Electrical and Chemical Interactions at Mars Workshop, hosted by NASA Lewis Research Center on November 19 and 20, 1991, was held with the following objectives in mind: (1) to identify issues related to electrical and chemical interactions between systems and their local environments on Mars, and (2) to recommend means of addressing those issues, including the dispatch of robotic spacecraft to Mars to acquire necessary information. The workshop began with presentations about Mars' surface and orbital environments, Space Exploration Initiative (SEI) systems, environmental interactions, modeling and analysis, and plans for exploration. Participants were then divided into two working groups: one to examine the surface of Mars; and the other, the orbit of Mars. The working groups were to identify issues relating to environmental interactions; to state for each issue what is known and what new knowledge is needed; and to recommend ways to fulfill the need. Issues were prioritized within each working group using the relative severity of effects as a criterion. Described here are the two working groups' contributions. A bibliography of materials used during the workshop and suggested reference materials is included.
NASA Astrophysics Data System (ADS)
Klyuev, R. V.; Bosikov, I. I.; Madaeva, M. Z.; A-V Turluev, R.
2018-03-01
The structural scheme of the automated control system of power consumption at the industrial enterprise is developed in the article. At the non-ferrous metallurgy enterprise, an energy inspection and a rank analysis of the electrical energy consumption of the main processing equipment were carried out. It is established that the enterprises of non-ferrous metallurgy are a complex process system consisting of a set of thousands of jointly functioning technological facilities. For the most effective estimation of power consumption of enterprises, it is reasonable to use the automated system of dispatching control of power consumption (ASDCPC). The paper presents the results of the development of the ASDCPC structural diagram that allows one to perform on-line control and management of the energy and process parameters of the main production units and the enterprise as a whole. As a result of the introduction of ASDCPC at the non-ferrous metallurgy enterprise, the consumed active power was reduced during the peak hours of the load by 20%, the specific electricity consumption - by 14%, the cost of the energy component in the cost of production of hard alloys - by 3%.
Testing of Strategies for the Acceleration of the Cost Optimization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ponciroli, Roberto; Vilim, Richard B.
The general problem addressed in the Nuclear-Renewable Hybrid Energy System (N-R HES) project is finding the optimum economical dispatch (ED) and capacity planning solutions for the hybrid energy systems. In the present test-problem configuration, the N-R HES unit is composed of three electrical power-generating components, i.e. the Balance of Plant (BOP), the Secondary Energy Source (SES), and the Energy Storage (ES). In addition, there is an Industrial Process (IP), which is devoted to hydrogen generation. At this preliminary stage, the goal is to find the power outputs of each one of the N-R HES unit components (BOP, SES, ES) andmore » the IP hydrogen production level that maximizes the unit profit by simultaneously satisfying individual component operational constraints. The optimization problem is meant to be solved in the Risk Analysis Virtual Environment (RAVEN) framework. The dynamic response of the N-R HES unit components is simulated by using dedicated object-oriented models written in the Modelica modeling language. Though this code coupling provides for very accurate predictions, the ensuing optimization problem is characterized by a very large number of solution variables. To ease the computational burden and to improve the path to a converged solution, a method to better estimate the initial guess for the optimization problem solution was developed. The proposed approach led to the definition of a suitable Monte Carlo-based optimization algorithm (called the preconditioner), which provides an initial guess for the optimal N-R HES power dispatch and the optimal installed capacity for each one of the unit components. The preconditioner samples a set of stochastic power scenarios for each one of the N-R HES unit components, and then for each of them the corresponding value of a suitably defined cost function is evaluated. After having simulated a sufficient number of power histories, the configuration which ensures the highest profit is selected as the optimal one. The component physical dynamics are represented through suitable ramp constraints, which considerably simplify the numerical solving. In order to test the capabilities of the proposed approach, in the present report, the dispatch problem only is tackled, i.e. a reference unit configuration is assumed, and each one of the N-R HES unit components is assumed to have a fixed installed capacity. As for the next steps, the main improvement will concern the operation strategy of the ES facility. In particular, in order to describe a more realistic battery commitment strategy, the ES operation will be regulated according to the electricity price forecasts.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Voisin, N.; Kintner-Meyer, M.; Wu, D.
The 2016 SECURE Water Act report’s natural water availability benchmark, combined with the 2010 level of water demand from an integrated assessment model, is used as input to drive a large-scale water management model. The regulated flow at hydropower plants and thermoelectric plants in the Western U.S. electricity grid (WECC) is translated into potential hydropower generation and generation capacity constraints. The impact on reliability (unserved energy, reserve margin) and cost (production cost, carbon emissions) of water constraints on 2010-level WECC power system operations is assessed using an electricity production cost model (PCM). Use of the PCM reveals the changes inmore » generation dispatch that reflect the inter-regional interdependencies in water-constrained generation and the ability to use other generation resources to meet all electricity loads in the WECC. August grid operational benchmarks show a range of sensitivity in production cost (-8 to +11%) and carbon emissions (-7 to 11%). The reference reserve margin threshold of 15% above peak load is maintained in the scenarios analyzed, but in 5 out of 55 years unserved energy is observed when normal operations are maintained. There is 1 chance in 10 that a year will demonstrate unserved energy in August, which defines the system’s historical performance threshold to support impact, vulnerability, and adaptation analysis. For seasonal and longer term planning, i.e., multi-year drought, we demonstrate how the Water Scarcity Grid Impact Factor and climate oscillations (ENSO, PDO) can be used to plan for joint water-electricity management to maintain grid reliability.« less
NASA Astrophysics Data System (ADS)
Yuan, Bo; Zong, Jin; Xu, Zhicheng
2018-06-01
According to different operating characteristics of pumped storage fixed speed unit and variable speed unit, a joint dispatching model of pumped storage unit and other types of units based on mixed integer linear optimization is constructed. The model takes into account the operating conditions, reservoir capacity, cycle type and other pumped storage unit constraints, but also consider the frequent start and stop and the stability of the operation of the unit caused by the loss. Using the Cplex solver to solve the model, the empirical example of the provincial power grid shows that the model can effectively arrange the pumping storage speed and the dispatching operation of the variable speed unit under the precondition of economic life of the unit, and give full play to the function of peak shaving and accommodating new energy. Because of its more flexible regulation characteristics of power generation and pumping conditions, the variable speed unit can better improve the operating conditions of other units in the system and promote the new energy dissipation.
Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
2018-01-03
While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less
Carbon Dioxide Emissions Effects of Grid-Scale Electricity Storage in a Decarbonizing Power System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
While grid-scale electricity storage (hereafter 'storage') could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO 2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO 2 emissions, we quantify the effect of storage on operational CO 2 emissions as a power system decarbonizes under a moderate and strong CO 2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO 2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. Wemore » conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO 2 emissions with and without storage. We find that storage would increase CO 2 emissions in the current ERCOT system, but would decrease CO 2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO 2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO 2 emissions.« less
Carbon dioxide emissions effects of grid-scale electricity storage in a decarbonizing power system
NASA Astrophysics Data System (ADS)
Craig, Michael T.; Jaramillo, Paulina; Hodge, Bri-Mathias
2018-01-01
While grid-scale electricity storage (hereafter ‘storage’) could be crucial for deeply decarbonizing the electric power system, it would increase carbon dioxide (CO2) emissions in current systems across the United States. To better understand how storage transitions from increasing to decreasing system CO2 emissions, we quantify the effect of storage on operational CO2 emissions as a power system decarbonizes under a moderate and strong CO2 emission reduction target through 2045. Under each target, we compare the effect of storage on CO2 emissions when storage participates in only energy, only reserve, and energy and reserve markets. We conduct our study in the Electricity Reliability Council of Texas (ERCOT) system and use a capacity expansion model to forecast generator fleet changes and a unit commitment and economic dispatch model to quantify system CO2 emissions with and without storage. We find that storage would increase CO2 emissions in the current ERCOT system, but would decrease CO2 emissions in 2025 through 2045 under both decarbonization targets. Storage reduces CO2 emissions primarily by enabling gas-fired generation to displace coal-fired generation, but also by reducing wind and solar curtailment. We further find that the market in which storage participates drives large differences in the magnitude, but not the direction, of the effect of storage on CO2 emissions.
Yu Wei; Michael Bevers; Erin J. Belval
2015-01-01
Initial attack dispatch rules can help shorten fire suppression response times by providing easy-to-follow recommendations based on fire weather, discovery time, location, and other factors that may influence fire behavior and the appropriate response. A new procedure is combined with a stochastic programming model and tested in this study for designing initial attack...
Multi-Agent simulation of generation capacity expansion decisions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Botterud, A.; Mahalik, M.; Conzelmann, G.
2008-01-01
In this paper, we use a multi-agent simulation model, EMCAS, to analyze generation expansion in the Iberian electricity market. The expansion model simulates generation investment decisions of decentralized generating companies (GenCos) interacting in a complex, multidimensional environment. A probabilistic dispatch algorithm calculates prices and profits for new candidate units in different future states of the system. Uncertainties in future load, hydropower conditions, and competitorspsila actions are represented in a scenario tree, and decision analysis is used to identify the optimal expansion decision for each individual GenCo. We run the model using detailed data for the Iberian market. In a scenariomore » analysis, we look at the impact of market design variables, such as the energy price cap and carbon emission prices. We also analyze how market concentration and GenCospsila risk preferences influence the timing and choice of new generating capacity.« less
The Proposal of the Model for Developing Dispatch System for Nationwide One-Day Integrative Planning
NASA Astrophysics Data System (ADS)
Kim, Hyun Soo; Choi, Hyung Rim; Park, Byung Kwon; Jung, Jae Un; Lee, Jin Wook
The problems of dispatch planning for container truck are classified as the pickup and delivery problems, which are highly complex issues that consider various constraints in the real world. However, in case of the current situation, it is developed by the control system so that it requires the automated planning system under the view of nationwide integrative planning. Therefore, the purpose of this study is to suggest model to develop the automated dispatch system through the constraint satisfaction problem and meta-heuristic technique-based algorithm. In the further study, the practical system is developed and evaluation is performed in aspect of various results. This study suggests model to undergo the study which promoted the complexity of the problems by considering the various constraints which were not considered in the early study. However, it is suggested that it is necessary to add the study which includes the real-time monitoring function for vehicles and cargos based on the information technology.
Microgrid to enable optimal distributed energy retail and end-user demand response
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jin, Ming; Feng, Wei; Marnay, Chris
In the face of unprecedented challenges in environmental sustainability and grid resilience, there is an increasingly held consensus regarding the adoption of distributed and renewable energy resources such as microgrids (MGs), and the utilization of flexible electric loads by demand response (DR) to potentially drive a necessary paradigm shift in energy production and consumption patterns. However, the potential value of distributed generation and demand flexibility has not yet been fully realized in the operation of MGs. This study investigates the pricing and operation strategy with DR for a MG retailer in an integrated energy system (IES). Based on co-optimizing retailmore » rates and MG dispatch formulated as a mixed integer quadratic programming (MIQP) problem, our model devises a dynamic pricing scheme that reflects the cost of generation and promotes DR, in tandem with an optimal dispatch plan that exploits spark spread and facilitates the integration of renewables, resulting in improved retailer profits and system stability. Main issues like integrated energy coupling and customer bill reduction are addressed during pricing to ensure rates competitiveness and customer protection. By evaluating on real datasets, the system is demonstrated to optimally coordinate storage, renewables, and combined heat and power (CHP), reduce carbon dioxide emission while maintaining profits, and effectively alleviate the PV curtailment problem. Finally, the model can be used by retailers and MG operators to optimize their operations, as well as regulators to design new utility rates in support of the ongoing transformation of energy systems.« less
Microgrid to enable optimal distributed energy retail and end-user demand response
Jin, Ming; Feng, Wei; Marnay, Chris; ...
2018-06-07
In the face of unprecedented challenges in environmental sustainability and grid resilience, there is an increasingly held consensus regarding the adoption of distributed and renewable energy resources such as microgrids (MGs), and the utilization of flexible electric loads by demand response (DR) to potentially drive a necessary paradigm shift in energy production and consumption patterns. However, the potential value of distributed generation and demand flexibility has not yet been fully realized in the operation of MGs. This study investigates the pricing and operation strategy with DR for a MG retailer in an integrated energy system (IES). Based on co-optimizing retailmore » rates and MG dispatch formulated as a mixed integer quadratic programming (MIQP) problem, our model devises a dynamic pricing scheme that reflects the cost of generation and promotes DR, in tandem with an optimal dispatch plan that exploits spark spread and facilitates the integration of renewables, resulting in improved retailer profits and system stability. Main issues like integrated energy coupling and customer bill reduction are addressed during pricing to ensure rates competitiveness and customer protection. By evaluating on real datasets, the system is demonstrated to optimally coordinate storage, renewables, and combined heat and power (CHP), reduce carbon dioxide emission while maintaining profits, and effectively alleviate the PV curtailment problem. Finally, the model can be used by retailers and MG operators to optimize their operations, as well as regulators to design new utility rates in support of the ongoing transformation of energy systems.« less
The new Venezuelan national control center
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beluche, C.M.
1984-07-01
This paper describes the actual status of the Venezuelan Electric Power System, the different operational areas involved, and finally the Interconnected System. Due to the development in the Power System, and in order to perform a more reliable and economic operation, it was established the need to implement a new supervisory system, for the Interconnected System Control Center. Also is described the system for the new control center for Oficina de Operacion de Sistemas Interconectados (OPSIS). OPSIS will monitor the Bulk Transmission Network (BTN), and will exchange information and control with the Regional Dispatch Centers through the computer network. Themore » Regional Dispatch Center (RDC) shall have the responsibility to accomplish the control order. The Bulk Transmissions System consists of that portion of the system from 800 KV to 230 KV. A total of six RDCs will be included in the system.« less
Boosting CSP Production with Thermal Energy Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Denholm, P.; Mehos, M.
2012-06-01
Combining concentrating solar power (CSP) with thermal energy storage shows promise for increasing grid flexibility by providing firm system capacity with a high ramp rate and acceptable part-load operation. When backed by energy storage capability, CSP can supplement photovoltaics by adding generation from solar resources during periods of low solar insolation. The falling cost of solar photovoltaic (PV) - generated electricity has led to a rapid increase in the deployment of PV and projections that PV could play a significant role in the future U.S. electric sector. The solar resource itself is virtually unlimited; however, the actual contribution of PVmore » electricity is limited by several factors related to the current grid. The first is the limited coincidence between the solar resource and normal electricity demand patterns. The second is the limited flexibility of conventional generators to accommodate this highly variable generation resource. At high penetration of solar generation, increased grid flexibility will be needed to fully utilize the variable and uncertain output from PV generation and to shift energy production to periods of high demand or reduced solar output. Energy storage is one way to increase grid flexibility, and many storage options are available or under development. In this article, however, we consider a technology already beginning to be used at scale - thermal energy storage (TES) deployed with concentrating solar power (CSP). PV and CSP are both deployable in areas of high direct normal irradiance such as the U.S. Southwest. The role of these two technologies is dependent on their costs and relative value, including how their value to the grid changes as a function of what percentage of total generation they contribute to the grid, and how they may actually work together to increase overall usefulness of the solar resource. Both PV and CSP use solar energy to generate electricity. A key difference is the ability of CSP to utilize high-efficiency TES, which turns CSP into a partially dispatchable resource. The addition of TES produces additional value by shifting the delivery of solar energy to periods of peak demand, providing firm capacity and ancillary services, and reducing integration challenges. Given the dispatchability of CSP enabled by TES, it is possible that PV and CSP are at least partially complementary. The dispatchability of CSP with TES can enable higher overall penetration of the grid by solar energy by providing solar-generated electricity during periods of cloudy weather or at night, when PV-generated power is unavailable. Such systems also have the potential to improve grid flexibility, thereby enabling greater penetration of PV energy (and other variable generation sources such as wind) than if PV were deployed without CSP.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Matthew; Simpkins, Travis; Cutler, Dylan
There is significant interest in using battery energy storage systems (BESS) to reduce peak demand charges, and therefore the life cycle cost of electricity, in commercial buildings. This paper explores the drivers of economic viability of BESS in commercial buildings through statistical analysis. A sample population of buildings was generated, a techno-economic optimization model was used to size and dispatch the BESS, and the resulting optimal BESS sizes were analyzed for relevant predictor variables. Explanatory regression analyses were used to demonstrate that peak demand charges are the most significant predictor of an economically viable battery, and that the shape ofmore » the load profile is the most significant predictor of the size of the battery.« less
A Statistical Analysis of the Economic Drivers of Battery Energy Storage in Commercial Buildings
DOE Office of Scientific and Technical Information (OSTI.GOV)
Long, Matthew; Simpkins, Travis; Cutler, Dylan
There is significant interest in using battery energy storage systems (BESS) to reduce peak demand charges, and therefore the life cycle cost of electricity, in commercial buildings. This paper explores the drivers of economic viability of BESS in commercial buildings through statistical analysis. A sample population of buildings was generated, a techno-economic optimization model was used to size and dispatch the BESS, and the resulting optimal BESS sizes were analyzed for relevant predictor variables. Explanatory regression analyses were used to demonstrate that peak demand charges are the most significant predictor of an economically viable battery, and that the shape ofmore » the load profile is the most significant predictor of the size of the battery.« less
Chance-constrained economic dispatch with renewable energy and storage
Cheng, Jianqiang; Chen, Richard Li-Yang; Najm, Habib N.; ...
2018-04-19
Increased penetration of renewables, along with uncertainties associated with them, have transformed how power systems are operated. High levels of uncertainty means that it is not longer possible to guarantee operational feasibility with certainty, instead constraints are required to be satisfied with high probability. We present a chance-constrained economic dispatch model that efficiently integrates energy storage and high renewable penetration to satisfy renewable portfolio requirements. Specifically, it is required that wind energy contributes at least a prespecified ratio of the total demand and that the scheduled wind energy is dispatchable with high probability. We develop an approximated partial sample averagemore » approximation (PSAA) framework to enable efficient solution of large-scale chanceconstrained economic dispatch problems. Computational experiments on the IEEE-24 bus system show that the proposed PSAA approach is more accurate, closer to the prescribed tolerance, and about 100 times faster than sample average approximation. Improved efficiency of our PSAA approach enables solution of WECC-240 system in minutes.« less
Chance-constrained economic dispatch with renewable energy and storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cheng, Jianqiang; Chen, Richard Li-Yang; Najm, Habib N.
Increased penetration of renewables, along with uncertainties associated with them, have transformed how power systems are operated. High levels of uncertainty means that it is not longer possible to guarantee operational feasibility with certainty, instead constraints are required to be satisfied with high probability. We present a chance-constrained economic dispatch model that efficiently integrates energy storage and high renewable penetration to satisfy renewable portfolio requirements. Specifically, it is required that wind energy contributes at least a prespecified ratio of the total demand and that the scheduled wind energy is dispatchable with high probability. We develop an approximated partial sample averagemore » approximation (PSAA) framework to enable efficient solution of large-scale chanceconstrained economic dispatch problems. Computational experiments on the IEEE-24 bus system show that the proposed PSAA approach is more accurate, closer to the prescribed tolerance, and about 100 times faster than sample average approximation. Improved efficiency of our PSAA approach enables solution of WECC-240 system in minutes.« less
Variable Renewable Energy in Long-Term Planning Models: A Multi-Model Perspective
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cole, Wesley J.; Frew, Bethany A.; Mai, Trieu T.
Long-term capacity expansion models of the U.S. electricity sector have long been used to inform electric sector stakeholders and decision makers. With the recent surge in variable renewable energy (VRE) generators - primarily wind and solar photovoltaics - the need to appropriately represent VRE generators in these long-term models has increased. VRE generators are especially difficult to represent for a variety of reasons, including their variability, uncertainty, and spatial diversity. To assess current best practices, share methods and data, and identify future research needs for VRE representation in capacity expansion models, four capacity expansion modeling teams from the Electric Powermore » Research Institute, the U.S. Energy Information Administration, the U.S. Environmental Protection Agency, and the National Renewable Energy Laboratory conducted two workshops of VRE modeling for national-scale capacity expansion models. The workshops covered a wide range of VRE topics, including transmission and VRE resource data, VRE capacity value, dispatch and operational modeling, distributed generation, and temporal and spatial resolution. The objectives of the workshops were both to better understand these topics and to improve the representation of VRE across the suite of models. Given these goals, each team incorporated model updates and performed additional analyses between the first and second workshops. This report summarizes the analyses and model 'experiments' that were conducted as part of these workshops as well as the various methods for treating VRE among the four modeling teams. The report also reviews the findings and learnings from the two workshops. We emphasize the areas where there is still need for additional research and development on analysis tools to incorporate VRE into long-term planning and decision-making.« less
Optimization Scheduling Model for Wind-thermal Power System Considering the Dynamic penalty factor
NASA Astrophysics Data System (ADS)
PENG, Siyu; LUO, Jianchun; WANG, Yunyu; YANG, Jun; RAN, Hong; PENG, Xiaodong; HUANG, Ming; LIU, Wanyu
2018-03-01
In this paper, a new dynamic economic dispatch model for power system is presented.Objective function of the proposed model presents a major novelty in the dynamic economic dispatch including wind farm: introduced the “Dynamic penalty factor”, This factor could be computed by using fuzzy logic considering both the variable nature of active wind power and power demand, and it could change the wind curtailment cost according to the different state of the power system. Case studies were carried out on the IEEE30 system. Results show that the proposed optimization model could mitigate the wind curtailment and the total cost effectively, demonstrate the validity and effectiveness of the proposed model.
University of Arizona Compressed Air Energy Storage
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simmons, Joseph; Muralidharan, Krishna
2012-12-31
Boiled down to its essentials, the grant’s purpose was to develop and demonstrate the viability of compressed air energy storage (CAES) for use in renewable energy development. While everyone agrees that energy storage is the key component to enable widespread adoption of renewable energy sources, the development of a viable scalable technology has been missing. The Department of Energy has focused on expanded battery research and improved forecasting, and the utilities have deployed renewable energy resources only to the extent of satisfying Renewable Portfolio Standards. The lack of dispatchability of solar and wind-based electricity generation has drastically increased the costmore » of operation with these components. It is now clear that energy storage coupled with accurate solar and wind forecasting make up the only combination that can succeed in dispatchable renewable energy resources. Conventional batteries scale linearly in size, so the price becomes a barrier for large systems. Flow batteries scale sub-linearly and promise to be useful if their performance can be shown to provide sufficient support for solar and wind-base electricity generation resources. Compressed air energy storage provides the most desirable answer in terms of scalability and performance in all areas except efficiency. With the support of the DOE, Tucson Electric Power and Science Foundation Arizona, the Arizona Research Institute for Solar Energy (AzRISE) at the University of Arizona has had the opportunity to investigate CAES as a potential energy storage resource.« less
NASA Astrophysics Data System (ADS)
Buscheck, T. A.; Randolph, J.; Saar, M. O.; Hao, Y.; Sun, Y.; Bielicki, J. M.
2014-12-01
Integrating renewable energy sources into electricity grids requires advances in bulk and thermal energy storage technologies, which are currently expensive and have limited capacity. We present an approach that uses the huge fluid and thermal storage capacity of the subsurface to harvest, store, and dispatch energy from subsurface (geothermal) and surface (solar, nuclear, fossil) thermal resources. CO2 captured from fossil-energy systems and N2 separated from air are injected into permeable formations to store pressure, generate artesian flow of brine, and provide additional working fluids. These enable efficient fluid recirculation, heat extraction, and power conversion, while adding operational flexibility. Our approach can also store and dispatch thermal energy, which can be used to levelize concentrating solar power and mitigate variability of wind and solar power. This may allow low-carbon, base-load power to operate at full capacity, with the stored excess energy being available to addresss diurnal and seasonal mismatches between supply and demand. Concentric rings of horizontal injection and production wells are used to create a hydraulic divide to store pressure, CO2, N2, and thermal energy. Such storage can take excess power from the grid and excess thermal energy, and dispatch that energy when it is demanded. The system is pressurized and/or heated when power supply exceeds demand and depressurized when demand exceeds supply. Supercritical CO2 and N2 function as cushion gases to provide enormous pressure-storage capacity. Injecting CO2 and N2 displaces large quantities of brine, reducing the use of fresh water. Geologic CO2 storage is a crucial option for reducing CO2 emissions, but valuable uses for CO2 are needed to justify capture costs. The initial "charging" of our system requires permanently isolating large volumes of CO2 from the atmosphere and thus creates a market for its disposal. Our approach is designed for locations where a permeable geologic formation is overlain by an impermeable formation that constrains migration of buoyant CO2 and/or N2, and heated brine. Such geologic conditions exist over nearly half of the contiguous United States. This work was performed under the auspices of the U.S. DOE by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Potential for deserts to supply reliable renewable electric power
NASA Astrophysics Data System (ADS)
Labordena, Mercè; Lilliestam, Johan
2015-04-01
To avoid dangerous climate change, the electricity systems must be decarbonized by mid-century. The world has sufficient renewable electricity resources for complete power sector decarbonization, but an expansion of renewables poses several challenges for the electricity systems. First, wind and solar PV power are intermittent and supply-controlled, making it difficult to securely integrate this fluctuating generation into the power systems. Consequently, power sources that are both renewable and dispatchable, such as biomass, hydro and concentrating solar power (CSP), are particularly important. Second, renewable power has a low power density and needs vast areas of land, which is problematic both due to cost reasons and due to land-use conflicts, in particular with agriculture. Renewable and dispatchable technologies that can be built in sparsely inhabited regions or on land with low competition with agriculture would therefore be especially valuable; this land-use competition greatly limits the potential for hydro and biomass electricity. Deserts, however, are precisely such low-competition land, and are at the same time the most suited places for CSP generation, but this option would necessitate long transmission lines from remote places in the deserts to the demand centers such as big cities. We therefore study the potential for fleets of CSP plants in the large deserts of the world to produce reliable and reasonable-cost renewable electricity for regions with high and/or rapidly increasing electricity demand and with a desert within or close to its borders. The regions in focus here are the European Union, North Africa and the Middle East, China and Australia. We conduct the analysis in three steps. First, we identify the best solar generation areas in the selected deserts using geographic information systems (GIS), and applying restrictions to minimize impact on biodiversity, soils, human heath, and land-use and land-cover change. Second, we identify transmission corridors from the generation areas to the demand centers in the target regions, using a GIS-based transmission algorithm that minimizes economic, social and environmental costs. Third, we use the multi-scale energy system model Calliope to specify the optimal configuration and operation of the CSP fleet to reliably follow the demand every hour of the year in the target regions, and to calculate the levelized cost of doing so, including both generation and transmission costs. The final output will show whether and how much reliable renewable electricity can be supplied from CSP fleets in deserts to demand centers in adjacent regions, at which costs this is possible, as well as a detailed description of the routes of HVDC transmission links. We expect to find that the potential for deserts to supply reliable CSP to the regions in focus is very large in all cases, despite the long distances.
NASA Astrophysics Data System (ADS)
2011-11-01
WE RECOMMEND Quantitative Understanding of Biosystems: An Introduction to Biophysics Text applies physics to biology concepts Edison's Electric Light: The Art of Invention Edison's light still shines brightly The Edge of Physics: Dispatches from the Frontiers of Cosmology Anecdotes explore cosmology Voicebox Voicebox kit discovers the physics and evolution of speech Tracker 4 Free software tracks motion analysis Hands-On Introduction to NI LabVIEW with Vernier, and Engineering Projects with NI LabVIEW and Vernier Books support the LabVIEW software Discovery Museum Newcastle museum offers science enjoyment for all Philosophy of Science: A Very Short Introduction Philosophy opens up science questions WORTH A LOOK The 4% Universe: Dark Matter, Dark Energy and the Race to Discover the Rest of Reality Book researches the universe WEB WATCH Superconductivity websites are popular
NASA Astrophysics Data System (ADS)
Pelzer, Dominik; Ciechanowicz, David; Aydt, Heiko; Knoll, Alois
2014-06-01
Employing electric vehicles as short-term energy storage could improve power system stability and at the same time create a new income source for vehicle owners. In this paper, the economic viability of this concept referred to as Vehicle-to-Grid is investigated. For this purpose, a price-responsive charging and dispatching strategy built upon temporally resolved electricity market data is presented. This concept allows vehicle owners to maximize returns by restricting market participation to profitable time periods. As a case study, this strategy is then applied using the example of Singapore. It is shown that an annual loss of S 1000 resulting from a non-price-responsive strategy as employed in previous works can be turned into a S 130 profit by applying the price-responsive approach. In addition to this scenario, realistic mobility patterns which restrict the temporal availability of vehicles are considered. In this case, profits in the range of S 21-S 121 are achievable. Returns in this order of magnitude are not expected to make Vehicle-to-Grid a viable business case, sensitivity analyses, however, show that improved technical parameters could increase profitability. It is further assumed that employing the price-responsive strategy to other national markets may yield significantly greater returns.
van Tulder, Raphael; Roth, Dominik; Laggner, Roberta; Krammel, Mario; Schriefl, Christoph; Kienbacher, Calvin; Novosad, Heinz; Chwojka, Constantin Christof; Sterz, Fritz; Havel, Christof; Schreiber, Wolfgang; Herkner, Harald
2017-02-01
The quality of telephone-assisted cardiopulmonary resuscitation (CPR) needs improvement. This study investigates whether a dispatchers' perception is an adequate measure of the actual quality of CPR provided by laypersons. Individual participant data from 3 randomized simulation trials, with identical methodology but different interventions, were combined for this analysis. Professional dispatchers gave telephone assistance to laypersons, who each provided 10 minutes of CPR on a manikin. Dispatchers were requested to classify the quality of providers' CPR as adequate or inadequate. Based on actual readings from manikins we classified providers' performance as adequate at 5-6 cm for depth and 100-120 compressions per minute (cpm) for rate. We calculated metrics of dispatcher accuracy. Six dispatchers rated the performance of 94 laypersons (38 women [42%]) with a mean (SD) age of 37 (14) years. In 905 analyzed minutes of telephone-assisted CPR, the mean compression depth and rate was 41 (13) mm and 98 (24) cpm, respectively. Analysis of dispatchers' diagnostic test accuracy for adequate compression depth yielded a sensitivity of 65% (95 CI 36%-95%) and specificity of 42% (95% CI, 32%-53%). Analysis of their assessment of adequate compression rate yielded a sensitivity of 75% (95% CI, 64%-86%) and specificity of 42% (95% CI, 32%-52%). Although dispatchers always underestimated the actual values of CPR parameters, the female dispatchers evaluations were less inaccurate than the evaluations of make dispatchers; the dispatchers overall (males and females together) underestimated the adequacy of female laypersons' CPR performance to a greater degree than female dispatchers did. The ability of dispatchers to estimate the quality of telephone-assisted CPR is limited. Dispatchers estimates of CPR adequacy needs to be studied further in order to find ways that telephone-assisted CPR might be improved.
The Mathematics of Dispatchability, Revisited
NASA Technical Reports Server (NTRS)
Morris, Paul
2016-01-01
Dispatchability is an important property for the efficient execution of temporal plans where the temporal constraints are represented as a Simple Temporal Network (STN). It has been shown that every STN may be reformulated as a dispatchable STN, and dispatchability ensures that the temporal constraints need only be satisfied locally during execution. Recently, it has also been shown that Simple Temporal Networks with Uncertainty, augmented with wait edges, are Dynamically Controllable provided every projection is dispatchable. Thus, dispatchability has considerable theoretical as well as practical significance. One thing that hampers further work in this area is the underdeveloped theory. Moreover, the existing foundation is inadequate in certain respects. In this paper, we develop a new mathematical theory of dispatchability and its relationship to execution. We also provide several characterizations of dispatchability, including characterizations in terms of the structural properties of the STN graph. This facilitates the potential application of the theory to other areas.
The Mathematics of Dispatchability Revisited
NASA Technical Reports Server (NTRS)
Morris, Paul
2016-01-01
Dispatchability is an important property for the efficient execution of temporal plans where the temporal constraints are represented as a Simple Temporal Network (STN). It has been shown that every STN may be reformulated as a dispatchable STN, and dispatchability ensures that the temporal constraints need only be satisfied locally during execution. Recently it has also been shown that Simple Temporal Networks with Uncertainty, augmented with wait edges, are Dynamically Controllable provided every projection is dispatchable. Thus, the dispatchability property has both theoretical and practical interest. One thing that hampers further work in this area is the underdeveloped theory. The existing definitions are expressed in terms of algorithms, and are less suitable for mathematical proofs. In this paper, we develop a new formal theory of dispatchability in terms of execution sequences. We exploit this to prove a characterization of dispatchability involving the structural properties of the STN graph. This facilitates the potential application of the theory to uncertainty reasoning.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Dias, F. G.; Luo, Y.; Mohanpurkar, M.
Since the modern-day introduction of plug-in electric vehicles (PEVs), scientists have proposed leveraging PEV battery packs as distributed energy resources for the electric grid. PEV charging can be controlled not only to provide energy for transportation but also to provide grid services and to facilitate the integration of renewable energy generation. With renewable generation increasing at an unprecedented rate, most of which is non-dispatchable and intermittent, the concept of using PEVs as controllable loads is appealing to electric utilities. This additional functionality could also provide value to PEV owners and drive PEV adoption. It has been widely proposed that PEVsmore » can provide valuable grid services, such as load shifting to provide voltage regulation. The objective this work is to address the degree to which PEVs can provide grid services and mutually benefit the electric utilities, PEV owners, and auto manufacturers.« less
Status Report on Modelling and Simulation Capabilities for Nuclear-Renewable Hybrid Energy Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rabiti, C.; Epiney, A.; Talbot, P.
This report summarizes the current status of the modeling and simulation capabilities developed for the economic assessment of Nuclear-Renewable Hybrid Energy Systems (N-R HES). The increasing penetration of variable renewables is altering the profile of the net demand, with which the other generators on the grid have to cope. N-R HES analyses are being conducted to determine the potential feasibility of mitigating the resultant volatility in the net electricity demand by adding industrial processes that utilize either thermal or electrical energy as stabilizing loads. This coordination of energy generators and users is proposed to mitigate the increase in electricity costmore » and cost volatility through the production of a saleable commodity. Overall, the financial performance of a system that is comprised of peaking units (i.e. gas turbine), baseload supply (i.e. nuclear power plant), and an industrial process (e.g. hydrogen plant) should be optimized under the constraint of satisfying an electricity demand profile with a certain level of variable renewable (wind) penetration. The optimization should entail both the sizing of the components/subsystems that comprise the system and the optimal dispatch strategy (output at any given moment in time from the different subsystems). Some of the capabilities here described have been reported separately in [1, 2, 3]. The purpose of this report is to provide an update on the improvement and extension of those capabilities and to illustrate their integrated application in the economic assessment of N-R HES.« less
NASA Astrophysics Data System (ADS)
Wu, Q. H.; Ma, J. T.
1993-09-01
A primary investigation into application of genetic algorithms in optimal reactive power dispatch and voltage control is presented. The application was achieved, based on (the United Kingdom) National Grid 48 bus network model, using a novel genetic search approach. Simulation results, compared with that obtained using nonlinear programming methods, are included to show the potential of applications of the genetic search methodology in power system economical and secure operations.
Transient analysis of a molten salt central receiver (MSCR) in a solar power plant
NASA Astrophysics Data System (ADS)
Joshi, A.; Wang, C.; Akinjiola, O.; Lou, X.; Neuschaefer, C.; Quinn, J.
2016-05-01
Alstom is developing solar power tower plants utilizing molten salt as the working fluid. In solar power tower, the molten salt central receiver (MSCR) atop of the tower is constructed of banks of tubes arranged in panels creating a heat transfer surface exposed to the solar irradiation from the heliostat field. The molten salt heat transfer fluid (HTF), in this case 60/40%wt NaNO3-KNO3, flows in serpentine flow through the surface collecting sensible heat thus raising the HTF temperature from 290°C to 565°C. The hot molten salt is stored and dispatched to produce superheated steam in a steam generator, which in turn produces electricity in the steam turbine generator. The MSCR based power plant with a thermal energy storage system (TESS) is a fully dispatchable renewable power plant with a number of opportunities for operational and economic optimization. This paper presents operation and controls challenges to the MSCR and the overall power plant, and the use of dynamic model computer simulation based transient analyses applied to molten salt based solar thermal power plant. This study presents the evaluation of the current MSCR design, using a dynamic model, with emphasis on severe events affecting critical process response, such as MS temperature deviations, and recommend MSCR control design improvements based on the results. Cloud events are the scope of the transient analysis presented in this paper. The paper presents results from a comparative study to examine impacts or effects on key process variables related to controls and operation of the MSCR plant.
14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...
14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...
14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...
14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...
14 CFR 65.67 - Aircraft dispatcher certification courses: Personnel.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Aircraft dispatcher certification courses....67 Aircraft dispatcher certification courses: Personnel. (a) Each applicant for an aircraft dispatcher certification course must meet the following personnel requirements: (1) Each applicant must have...
NASA Astrophysics Data System (ADS)
Voisin, N.; Macknick, J.; Fu, T.; O'Connell, M.; Zhou, T.; Brinkman, G.
2017-12-01
Water resources provide multiple critical services to the electrical grid through hydropower technologies, from generation to regulation of the electric grid (frequency, capacity reserve). Water resources can also represent vulnerabilities to the electric grid, as hydropower and thermo-electric facilities require water for operations. In the Western U.S., hydropower and thermo-electric plants that rely on fresh surface water represent 67% of the generating capacity. Prior studies have looked at the impact of change in water availability under future climate conditions on expected generating capacity in the Western U.S., but have not evaluated operational risks or changes resulting from climate. In this study, we systematically assess the impact of change in water availability and air temperatures on power operations, i.e. we take into account the different grid services that water resources can provide to the electric grid (generation, regulation) in the system-level context of inter-regional coordination through the electric transmission network. We leverage the Coupled Model Intercomparison Project Phase 5 (CMIP5) hydrology simulations under historical and future climate conditions, and force the large scale river routing- water management model MOSART-WM along with 2010-level sectoral water demands. Changes in monthly hydropower potential generation (including generation and reserves), as well as monthly generation capacity of thermo-electric plants are derived for each power plant in the Western U.S. electric grid. We then utilize the PLEXOS electricity production cost model to optimize power system dispatch and cost decisions for the 2010 infrastructure under 100 years of historical and future (2050 horizon) hydroclimate conditions. We use economic metrics as well as operational metrics such as generation portfolio, emissions, and reserve margins to assess the changes in power system operations between historical and future normal and extreme water availability conditions. We provide insight on how this information can be used to support resource adequacy and grid expansion studies over the Western U.S. in the context of inter-annual variability and climate change.
NASA Astrophysics Data System (ADS)
Brereton, Beverly Ann
The interconnection of neighboring electricity networks provides opportunities for the realization of synergies between electricity systems. Examples of the synergies to be realized are the rationalized management of the electricity networks whose fuel source domination differs, and the exploitation of non-coincident system peak demands. These factors allow technology diversity in the satisfaction of electricity demand, the coordination of planning and maintenance schedules between the networks by exploiting the cost differences in the pool of generation assets and the load configuration differences in the neighboring locations. The interconnection decision studied in this dissertation focused on the electricity networks of Argentina and Chile whose electricity systems operate in isolation at the current time. The cooperative game-theoretic framework was applied in the analysis of the decision facing the two countries and the net surplus to be derived from interconnection was evaluated. Measurement of the net gains from interconnection used in this study were reflected in changes in generating costs under the assumption that demand is fixed under all scenarios. With the demand for electricity assumed perfectly inelastic, passive or aggressive bidding strategies were considered under the scenarios for the generators in the two countries. The interconnection decision was modeled using a linear power flow model which utilizes linear programming techniques to reflect dispatch procedures based on generation bids. Results of the study indicate that the current interconnection project between Argentina and Chile will not result in positive net surplus under a variety of scenarios. Only under significantly reduced interconnection cost will the venture prove attractive. Possible sharing mechanisms were also explored in the research and a symmetric distribution of the net surplus to be derived under the reduced interconnection cost scenario was recommended to preserve equity in the allocation of the interconnection gains.
NASA Astrophysics Data System (ADS)
Nguyen, Gia Luong Huu
Fuel cells can produce electricity with high efficiency, low pollutants, and low noise. With the advent of fuel cell technologies, fuel cell systems have since been demonstrated as reliable power generators with power outputs from a few watts to a few megawatts. With proper equipment, fuel cell systems can produce heating and cooling, thus increased its overall efficiency. To increase the acceptance from electrical utilities and building owners, fuel cell systems must operate more dynamically and integrate well with renewable energy resources. This research studies the dynamic performance of fuel cells and the integration of fuel cells with other equipment in three levels: (i) the fuel cell stack operating on hydrogen and reformate gases, (ii) the fuel cell system consisting of a fuel reformer, a fuel cell stack, and a heat recovery unit, and (iii) the hybrid energy system consisting of photovoltaic panels, fuel cell system, and energy storage. In the first part, this research studied the steady-state and dynamic performance of a high temperature PEM fuel cell stack. Collaborators at Aalborg University (Aalborg, Denmark) conducted experiments on a high temperature PEM fuel cell short stack at steady-state and transients. Along with the experimental activities, this research developed a first-principles dynamic model of a fuel cell stack. The dynamic model developed in this research was compared to the experimental results when operating on different reformate concentrations. Finally, the dynamic performance of the fuel cell stack for a rapid increase and rapid decrease in power was evaluated. The dynamic model well predicted the performance of the well-performing cells in the experimental fuel cell stack. The second part of the research studied the dynamic response of a high temperature PEM fuel cell system consisting of a fuel reformer, a fuel cell stack, and a heat recovery unit with high thermal integration. After verifying the model performance with the obtained experimental data, the research studied the control of airflow to regulate the temperature of reactors within the fuel processor. The dynamic model provided a platform to test the dynamic response for different control gains. With sufficient sensing and appropriate control, a rapid response to maintain the temperature of the reactor despite an increase in power was possible. The third part of the research studied the use of a fuel cell in conjunction with photovoltaic panels, and energy storage to provide electricity for buildings. This research developed an optimization framework to determine the size of each device in the hybrid energy system to satisfy the electrical demands of buildings and yield the lowest cost. The advantage of having the fuel cell with photovoltaic and energy storage was the ability to operate the fuel cell at baseload at night, thus reducing the need for large battery systems to shift the solar power produced in the day to the night. In addition, the dispatchability of the fuel cell provided an extra degree of freedom necessary for unforeseen disturbances. An operation framework based on model predictive control showed that the method is suitable for optimizing the dispatch of the hybrid energy system.
Energy-Water-Land-Climate Nexus: Modeling Impacts from the Asset to Regional Scale
NASA Astrophysics Data System (ADS)
Tidwell, V. C.; Bennett, K. E.; Middleton, R. S.; Behery, S.; Macknick, J.; Corning-Padilla, A.; Brinkman, G.; Meng, M.
2016-12-01
A critical challenge for the energy-water-land nexus is understanding and modeling the connection between the natural system—including changes in climate, land use/cover, and streamflow—and the engineered system including water for energy, agriculture, and society. Equally important is understanding the linkage across scales; that is, how impacts at the asset level aggregate to influence behavior at the local to regional scale. Toward this need, a case study was conducted featuring multi-sector and multi-scale modeling centered on the San Juan River basin (a watershed that accounts for one-tenth of the Colorado River drainage area). Simulations were driven by statistically downscaled climate data from three global climate models (emission scenario RCP 8.5) and planned growth in regional water demand. The Variable Infiltration Capacity (VIC) hydrologic model was fitted with a custom vegetation mortality sub-model and used to estimate tributary inflows to the San Juan River and estimate reservoir evaporation. San Juan River operations, including releases from Navajo Reservoir, were subsequently modeled using RiverWare to estimate impacts on water deliveries out to the year 2100. Major water demands included two large coal-fired power plants, a local electric utility, river-side irrigation, the Navajo Indian Irrigation Project and instream flows managed for endangered aquatic species. Also tracked were basin exports, including water (downstream flows to the Colorado River and interbasin transfers to the Rio Grande) and interstate electric power transmission. Implications for the larger western electric grid were assessed using PLEXOS, a sub-hourly dispatch, electric production-cost model. Results highlight asset-level interactions at the energy-water-land nexus driven by climate and population dynamics; specifically, growing vulnerabilities to shorted water deliveries. Analyses also explored linkages across geographic scales from the San Juan to the larger Colorado River and Rio Grande basins as well as the western power grid.
Dispatcher Recognition of Stroke Using the National Academy Medical Priority Dispatch System
Buck, Brian H; Starkman, Sidney; Eckstein, Marc; Kidwell, Chelsea S; Haines, Jill; Huang, Rainy; Colby, Daniel; Saver, Jeffrey L
2009-01-01
Background Emergency Medical Dispatchers (EMDs) play an important role in optimizing stroke care if they are able to accurately identify calls regarding acute cerebrovascular disease. This study was undertaken to assess the diagnostic accuracy of the current national protocol guiding dispatcher questioning of 911 callers to identify stroke, QA Guide v 11.1 of the National Academy Medical Priority Dispatch System (MPDS). Methods We identified all Los Angeles Fire Department paramedic transports of patients to UCLA Medical Center during the 12 month period from January to December 2005 in a prospectively maintained database. Dispatcher-assigned MPDS codes for each of these patient transports were abstracted from the paramedic run sheets and compared to final hospital discharge diagnosis. Results Among 3474 transported patients, 96 (2.8%) had a final diagnosis of stroke or transient ischemic attack. Dispatchers assigned a code of potential stroke to 44.8% of patients with a final discharge diagnosis of stroke or TIA. Dispatcher identification of stroke showed a sensitivity of 0.41, specificity of 0.96, positive predictive value of 0.45, and negative predictive value of 0.95. Conclusions Dispatcher recognition of stroke calls using the widely employed MPDS algorithm is suboptimal, with failure to identify more than half of stroke patients as likely stroke. Revisions to the current national dispatcher structured interview and complaint identification algorithm for stroke may facilitate more accurate recognition of stroke by EMDs. PMID:19390065
NASA Astrophysics Data System (ADS)
Zhang, Kai; Li, Jingzhi; He, Zhubin; Yan, Wanfeng
2018-07-01
In this paper, a stochastic optimization framework is proposed to address the microgrid energy dispatching problem with random renewable generation and vehicle activity pattern, which is closer to the practical applications. The patterns of energy generation, consumption and storage availability are all random and unknown at the beginning, and the microgrid controller design (MCD) is formulated as a Markov decision process (MDP). Hence, an online learning-based control algorithm is proposed for the microgrid, which could adapt the control policy with increasing knowledge of the system dynamics and converges to the optimal algorithm. We adopt the linear approximation idea to decompose the original value functions as the summation of each per-battery value function. As a consequence, the computational complexity is significantly reduced from exponential growth to linear growth with respect to the size of battery states. Monte Carlo simulation of different scenarios demonstrates the effectiveness and efficiency of our algorithm.
Application of computer-aided dispatch in law enforcement: An introductory planning guide
NASA Technical Reports Server (NTRS)
Sohn, R. L.; Gurfield, R. M.; Garcia, E. A.; Fielding, J. E.
1975-01-01
A set of planning guidelines for the application of computer-aided dispatching (CAD) to law enforcement is presented. Some essential characteristics and applications of CAD are outlined; the results of a survey of systems in the operational or planning phases are summarized. Requirements analysis, system concept design, implementation planning, and performance and cost modeling are described and demonstrated with numerous examples. Detailed descriptions of typical law enforcement CAD systems, and a list of vendor sources, are given in appendixes.
Handling of drug-related emergencies: an evaluation of emergency medical dispatch.
Tonje, Lorem; Elisabeth, Saether; Lars, Wik
2009-02-01
Documenting the quality of emergency dispatch centres handling of emergency calls regarding intoxicated unconscious patients. Interview with eight emergency dispatch centre directors and a nationwide survey among 313 dispatchers in Norway were performed. In addition, a customized scoring system was used to evaluate dispatcher log recordings of real cases. The recordings were compared with information from corresponding ambulance records. Ninety-nine percent of the dispatchers stated that they used the Norwegian protocol for medical emergencies and 89% of them found it useful. The interviews, the survey, and the recordings, however, documented frequent deviation from the protocol. This instructs ambulance dispatch for any unconscious patient, but 21% stated that they would not dispatch any resource for an unconscious patient without further survey in alcohol-related cases. This was significantly more often (P<0.05) than for the narcotic, combination and prescription - drug-related cases with 4, 10 and 7%, respectively. The recordings revealed deviation from the protocol with dispatchers only determining the patients' level of consciousness and respiratory status in 64 and 70% of the cases, respectively. For 16% of the cases, the dispatcher did not ask the caller about consciousness at all, even though these patients later were found with reduced consciousness. On the basis of the interviews and the survey, cases were handled according to guidelines. The log recordings, however, disclosed deviation from the protocol. Alcohol intoxication was associated with higher rate of deviation from the protocol compared with other intoxications.
Bakke, Håkon Kvåle; Steinvik, Tine; Ruud, Håkon; Wisborg, Torben
2017-03-07
Emergency medical communication centres (EMCCs) dispatch and allocate ambulance resources, and provide first-aid guidance to on-scene bystanders. We aimed to 1) evaluate whether dispatcher guidance improved bystander first aid in trauma, and 2) to evaluate whether dispatchers and on-scene emergency medical services (EMS) crews identified the same first aid measures as indicated. For 18 months, the crew on the first EMS crew responding to trauma calls used a standard form to assess bystander first aid. Audio recordings of the corresponding telephone calls from bystanders to the EMCC were reviewed. A total of 311 trauma calls were included. The on-scene EMS crew identified needs for the following first-aid measures: free airway in 26 patients, CPR in 6 patients, and hypothermia prevention in 179 patients. EMCC dispatchers advised these measures, respectively, in 16 (62%), 5 (83%), and 54 (30%) of these cases. Dispatcher guidance was not correlated with correctly performed bystander first aid. For potentially life saving first aid measures, all (20/20) callers who received dispatcher guidance attempted first aid, while only some few (4/22) of the callers who did not receive dispatcher guidance did not attempt first aid. Overall, the EMCC dispatchers had low sensitivity and specificity for correctly identifying trauma patients requiring first-aid measures. Dispatcher guidance did not significantly influence whether on-scene bystander first aid was performed correctly or attempted in this study setting, with a remarkably high willingness to perform first-aid. However, the findings for potentially lifesaving measures suggests that there may be differences that this study was unable to detect. This study found a high rate of first-aid willingness and performance, even without dispatcher prompting, and a low precision in dispatcher advice. This underlines the need for further knowledge about how to increase EMCC dispatchers' possibility to identify trauma patients in need of first aid. The correlation between EMCC-guidance and bystander first aid should be investigated in study settings with lower spontaneous first-aid rates.
NASA Technical Reports Server (NTRS)
Forbes, Kevin F.; Cyr, Chris St
2012-01-01
During solar cycle 22, a very intense geomagnetic storm on 13 March 1989 contributed to the collapse of the Hydro-Quebec power system in Canada. This event clearly demonstrated that geomagnetic storms have the potential to lead to blackouts. This paper addresses whether geomagnetic activity challenged power system reliability during solar cycle 23. Operations by PJM Interconnection, LLC (hereafter PJM), a regional transmission organization in North America, are examined over the period 1 April 2002 through 30 April 2004. During this time PJM coordinated the movement of wholesale electricity in all or parts of Delaware, Maryland, New Jersey, Ohio, Pennsylvania, Virginia, West Virginia, and the District of Columbia in the United States. We examine the relationship between a proxy of geomagnetically induced currents (GICs) and a metric of challenged reliability. In this study, GICs are proxied using magnetometer data from a geomagnetic observatory located just outside the PJM control area. The metric of challenged reliability is the incidence of out-of-economic-merit order dispatching due to adverse reactive power conditions. The statistical methods employed make it possible to disentangle the effects of GICs on power system operations from purely terrestrial factors. The results of the analysis indicate that geomagnetic activity can significantly increase the likelihood that the system operator will dispatch generating units based on system stability considerations rather than economic merit.
NASA Astrophysics Data System (ADS)
Chintalapudi, V. S.; Sirigiri, Sivanagaraju
2017-04-01
In power system restructuring, pricing the electrical power plays a vital role in cost allocation between suppliers and consumers. In optimal power dispatch problem, not only the cost of active power generation but also the costs of reactive power generated by the generators should be considered to increase the effectiveness of the problem. As the characteristics of reactive power cost curve are similar to that of active power cost curve, a nonconvex reactive power cost function is formulated. In this paper, a more realistic multi-fuel total cost objective is formulated by considering active and reactive power costs of generators. The formulated cost function is optimized by satisfying equality, in-equality and practical constraints using the proposed uniform distributed two-stage particle swarm optimization. The proposed algorithm is a combination of uniform distribution of control variables (to start the iterative process with good initial value) and two-stage initialization processes (to obtain best final value in less number of iterations) can enhance the effectiveness of convergence characteristics. Obtained results for the considered standard test functions and electrical systems indicate the effectiveness of the proposed algorithm and can obtain efficient solution when compared to existing methods. Hence, the proposed method is a promising method and can be easily applied to optimize the power system objectives.
Analysis of a Concentrated Solar Thermophotovoltaic System with Thermal Energy Storage
NASA Astrophysics Data System (ADS)
Seyf, Hamid Reza; Henry, Asegun
2017-01-01
We analyzed a high temperature concentrated solar thermophotovoltaic (TPV) system with thermal energy storage (TES), which is enabled by the potential usage of liquid metal as a high temperature heat transfer fluid. The system concept combines the great advantages of TES with the potential for low cost and high performance derived from photovoltaic cells fabricated on reusable substrates, with a high reflectivity back reflector for photon recycling. The TES makes the electricity produced dispatchable, and thus the system studied should be compared to technologies such as concentrated solar power (CSP) with TES (e.g., using a turbine) or PV with electrochemical batteries, instead of direct and intermittent electricity generation from flat plate PV alone. Thus, the addition of TES places the system in a different class than has previously been considered and based on the model results, appears worthy of increased attention. The system level analysis presented identifies important cell level parameters that have the greatest impact on the overall system performance, and as a result can help to set the priorities for future TPV cell development.
Analysis of a Concentrated Solar Thermophotovoltaic System with Thermal Energy Storage
NASA Astrophysics Data System (ADS)
Seyf, Hamid Reza; Henry, Asegun
We analyzed a high temperature concentrated solar thermophotovoltaic (TPV) system with thermal energy storage (TES), which is enabled by the potential usage of liquid metal as a high temperature heat transfer fluid. The system concept combines the great advantages of TES with the potential for low cost and high performance derived from photovoltaic cells fabricated on reusable substrates, with a high reflectivity back reflector for photon recycling. The TES makes the electricity produced dispatchable, and thus the system studied should be compared to technologies such as concentrated solar power (CSP) with TES (e.g., using a turbine) or PV with electrochemical batteries, instead of direct and intermittent electricity generation from flat plate PV alone. Thus, the addition of TES places the system in a different class than has previously been considered and based on the model results, appears worthy of increased attention. The system level analysis presented identifies important cell level parameters that have the greatest impact on the overall system performance, and as a result can help to set the priorities for future TPV cell development.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yeh, Sonia; Yang, Christopher; Gibbs, Michael
California aims to reduce greenhouse gas (GHG) emissions to 40% below 1990 levels by 2030. We compare six energy models that have played various roles in informing the state policymakers in setting climate policy goals and targets. These models adopt a range of modeling structures, including stock-turnover back-casting models, a least-cost optimization model, macroeconomic/macro-econometric models, and an electricity dispatch model. Results from these models provide useful insights in terms of the transformations in the energy system required, including efficiency improvements in cars, trucks, and buildings, electrification of end-uses, low- or zero-carbon electricity and fuels, aggressive adoptions of zero-emission vehicles (ZEVs),more » demand reduction, and large reductions of non-energy GHG emissions. Some of these studies also suggest that the direct economic costs can be fairly modest or even generate net savings, while the indirect macroeconomic benefits are large, as shifts in employment and capital investments could have higher economic returns than conventional energy expenditures. These models, however, often assume perfect markets, perfect competition, and zero transaction costs. They also do not provide specific policy guidance on how these transformative changes can be achieved. Greater emphasis on modeling uncertainty, consumer behaviors, heterogeneity of impacts, and spatial modeling would further enhance policymakers' ability to design more effective and targeted policies. Here, this paper presents an example of how policymakers, energy system modelers and stakeholders interact and work together to develop and evaluate long-term state climate policy targets. Lastly, even though this paper focuses on California, the process of dialogue and interactions, modeling results, and lessons learned can be generally adopted across different regions and scales.« less
NASA Astrophysics Data System (ADS)
Samsinar, Riza; Suseno, Jatmiko Endro; Widodo, Catur Edi
2018-02-01
The distribution network is the closest power grid to the customer Electric service providers such as PT. PLN. The dispatching center of power grid companies is also the data center of the power grid where gathers great amount of operating information. The valuable information contained in these data means a lot for power grid operating management. The technique of data warehousing online analytical processing has been used to manage and analysis the great capacity of data. Specific methods for online analytics information systems resulting from data warehouse processing with OLAP are chart and query reporting. The information in the form of chart reporting consists of the load distribution chart based on the repetition of time, distribution chart on the area, the substation region chart and the electric load usage chart. The results of the OLAP process show the development of electric load distribution, as well as the analysis of information on the load of electric power consumption and become an alternative in presenting information related to peak load.
Spatially and Temporally Resolved Analysis of Environmental Trade-Offs in Electricity Generation.
Peer, Rebecca A M; Garrison, Jared B; Timms, Craig P; Sanders, Kelly T
2016-04-19
The US power sector is a leading contributor of emissions that affect air quality and climate. It also requires a lot of water for cooling thermoelectric power plants. Although these impacts affect ecosystems and human health unevenly in space and time, there has been very little quantification of these environmental trade-offs on decision-relevant scales. This work quantifies hourly water consumption, emissions (i.e., carbon dioxide, nitrogen oxides, and sulfur oxides), and marginal heat rates for 252 electricity generating units (EGUs) in the Electric Reliability Council of Texas (ERCOT) region in 2011 using a unit commitment and dispatch model (UC&D). Annual, seasonal, and daily variations, as well as spatial variability are assessed. When normalized over the grid, hourly average emissions and water consumption intensities (i.e., output per MWh) are found to be highest when electricity demand is the lowest, as baseload EGUs tend to be the most water and emissions intensive. Results suggest that a large fraction of emissions and water consumption are caused by a small number of power plants, mainly baseload coal-fired generators. Replacing 8-10 existing power plants with modern natural gas combined cycle units would result in reductions of 19-29%, 51-55%, 60-62%, and 13-27% in CO2 emissions, NOx emissions, SOx emissions, and water consumption, respectively, across the ERCOT region for two different conversion scenarios.
NASA Astrophysics Data System (ADS)
Sharma, Pankaj; Jain, Ajai
2014-12-01
Stochastic dynamic job shop scheduling problem with consideration of sequence-dependent setup times are among the most difficult classes of scheduling problems. This paper assesses the performance of nine dispatching rules in such shop from makespan, mean flow time, maximum flow time, mean tardiness, maximum tardiness, number of tardy jobs, total setups and mean setup time performance measures viewpoint. A discrete event simulation model of a stochastic dynamic job shop manufacturing system is developed for investigation purpose. Nine dispatching rules identified from literature are incorporated in the simulation model. The simulation experiments are conducted under due date tightness factor of 3, shop utilization percentage of 90% and setup times less than processing times. Results indicate that shortest setup time (SIMSET) rule provides the best performance for mean flow time and number of tardy jobs measures. The job with similar setup and modified earliest due date (JMEDD) rule provides the best performance for makespan, maximum flow time, mean tardiness, maximum tardiness, total setups and mean setup time measures.
New scheduling rules for a dynamic flexible flow line problem with sequence-dependent setup times
NASA Astrophysics Data System (ADS)
Kia, Hamidreza; Ghodsypour, Seyed Hassan; Davoudpour, Hamid
2017-09-01
In the literature, the application of multi-objective dynamic scheduling problem and simple priority rules are widely studied. Although these rules are not efficient enough due to simplicity and lack of general insight, composite dispatching rules have a very suitable performance because they result from experiments. In this paper, a dynamic flexible flow line problem with sequence-dependent setup times is studied. The objective of the problem is minimization of mean flow time and mean tardiness. A 0-1 mixed integer model of the problem is formulated. Since the problem is NP-hard, four new composite dispatching rules are proposed to solve it by applying genetic programming framework and choosing proper operators. Furthermore, a discrete-event simulation model is made to examine the performances of scheduling rules considering four new heuristic rules and the six adapted heuristic rules from the literature. It is clear from the experimental results that composite dispatching rules that are formed from genetic programming have a better performance in minimization of mean flow time and mean tardiness than others.
Evaluating policy-relevant emission inventories for transportation and electricity (Invited)
NASA Astrophysics Data System (ADS)
Holloway, T.; Meier, P.; Bickford, E. E.
2013-12-01
We explore the challenges and opportunities in evaluating bottom-up emission inventories for transportation and electricity. These anthropogenic emissions respond in complex ways to technology and activity changes. Thus, it is essential that inventories capture historic emissions consistent with observations, as well as future emissions consistent with policy scenarios. For transportation, we focus on freight-related trucking emissions, represented by the Wisconsin Inventory for Freight Emissions (WIFE), developed with activity data from the U.S. Federal Highway Administration Freight Analysis Framework and emission factors from the EPA MOVES model. Because WIFE is linked to commodity flows and roadway speeds, it offers a useful data set to evaluate policy changes such as truck-to-rail modal shifts and alternative fuel choices. However, the value of the inventory in assessing these scenarios depends on its skill in calculating frieght-related emissions. Satellite data of nitrogen dioxide (NO2) from the OMI instrument aboard the NASA Aura satellite is used to evaluate truck and rail NOx emissions, especially on rural highways away from ground-based monitors. For electricity, we use the MyPower electricity dispatch model to calculate emissions and power generation in response to policy and technology changes. These include renewable portfolio standards, conservation, increased natural gas, and response to building demand. To evaluate MyPower, we compare with the Clean Air Markets database, and 2007 calculated daily afternoon emissions with satellite-derived NO2 from OMI. Drawing on the results of these studies, we discuss strategies to meet the information demands of both historically correct air quality inputs and future-relevant policy scenarios.
Dispatcher assistance and automated external defibrillator performance among elders.
Ecker, R; Rea, T D; Meischke, H; Schaeffer, S M; Kudenchuk, P; Eisenberg, M S
2001-10-01
Automated external defibrillators (AEDs) provide an opportunity to improve survival in out-of-hospital, ventricular fibrillation (VF) cardiac arrest by enabling laypersons not trained in rhythm recognition to deliver lifesaving therapy. The potential role of emergency dispatchers in the layperson use of AEDs is uncertain. This study was performed to examine whether dispatcher telephone assistance affected AED skill performance during a simulated VF cardiac arrest among a cohort of older adults. The hypothesis was that dispatcher assistance would increase the proportion who were able to correctly deliver a shock, but might require additional time. One hundred fifty community-dwelling persons aged 58-84 years were recruited from eight senior centers in King County, Washington. All participants had received AED training approximately six months previously. For this study, the participants were randomized to AED operation with or without dispatcher assistance during a simulated VF cardiac arrest. The proportions who successfully delivered a shock and the time intervals from collapse to shock were compared between the two groups. The participants who received dispatcher assistance were more likely to correctly deliver a shock with the AED during the simulated VF cardiac arrest (91% vs 68%, p = 0.001). Among those who were able to deliver a shock, the participants who received dispatcher assistance required a longer time interval from collapse to shock [median (25th, 75th percentile) = 193 seconds (165, 225) for dispatcher assistance, and 148 seconds (138, 166) for no dispatcher assistance, p = 0.001]. Among older laypersons previously trained in AED operation, dispatcher assistance may increase the proportion who can successfully deliver a shock during a VF cardiac arrest.
Buscheck, Thomas A.
2015-12-01
It’s the bane of renewable energy. No matter how efficient photovoltaic cells become or how much power a wind turbine can capture, someone will counter with, “What happens when the sun goes down and wind doesn’t blow?” And the person who poses that question uses it as an argument in favor of traditional baseload power. While it’s true that the way the electrical grid has developed in North America and Europe doesn’t lend itself to the start-and-stop, opportunistic nature of wind and solar, there are ways to meet the challenge. Electricity can be stored in batteries or water pumped uphillmore » into reservoirs when power generation exceeds demand, to be tapped when needed. Unfortunately, utility-scale battery storage is prohibitively expensive, and pumped hydro is possible only in particular geographic locations. What is needed is a large-scale, distributed, dispatchable energy storage system that can smooth out a renewable energy generation profile that changes by the minute as well as over the course of the day or the season. Colleagues from Lawrence Livermore National Laboratory, the Ohio State University (led by Jeffrey Bielicki), and the University of Minnesota (led by Jimmy Randolph), and I have developed a system that can do all that. What’s more, this system actually sequesters carbon dioxide—a gas implicated in global climate change—as part of its normal operation. Furthermore, we have modeled our system and found that, if it can be successfully demonstrated in the field, it could provide utility-scale diurnal and seasonal energy storage (many hundreds of MWe) and dispatchable power, while permanently sequestering CO 2 from industrial-scale fossil-energy power plants. Certainly, an energy storage system is only as clean or as green as the primary generation it’s working with. But it is going to be difficult to implement solar or wind power to a degree high enough to make a difference in global carbon dioxide emissions without utility-scale energy storage.« less
NASA Astrophysics Data System (ADS)
Moukhtar, Ibrahim; Elbaset, Adel A.; El Dein, Adel Z.; Qudaih, Yaser; Mitani, Yasunori
2018-05-01
Photovoltaic (PV) system integration in the electric grid has been increasing over the past decades. However, the impact of PV penetration on the electric grid, especially during the periods of higher and lower generation for the solar system at the middle of the day and during cloudy weather or at night respectively, limit the high penetration of solar PV system. In this research, a Concentrated Solar Power (CSP) with Thermal Energy Storage (TES) has been aggregated with PV system in order to accommodate the required electrical power during the higher and lower solar energy at all timescales. This paper analyzes the impacts of CSP on the grid-connected PV considering high penetration of PV system, particularly when no energy storages in the form of batteries are used. Two cases have been studied, the first when only PV system is integrated into the electric grid and the second when two types of solar energy (PV and CSP) are integrated. The System Advisor Model (SAM) software is used to simulate the output power of renewable energy. Simulation results show that the performance of CSP has a great impact on the penetration level of PV system and on the flexibility of the electric grid. The overall grid flexibility increases due to the ability of CSP to store and dispatch the generated power. In addition, CSP/TES itself has inherent flexibility. Therefore, CSP reduces the minimum generation constraint of the conventional generators that allows more penetration of the PV system.
Multicriteria meta-heuristics for AGV dispatching control based on computational intelligence.
Naso, David; Turchiano, Biagio
2005-04-01
In many manufacturing environments, automated guided vehicles are used to move the processed materials between various pickup and delivery points. The assignment of vehicles to unit loads is a complex problem that is often solved in real-time with simple dispatching rules. This paper proposes an automated guided vehicles dispatching approach based on computational intelligence. We adopt a fuzzy multicriteria decision strategy to simultaneously take into account multiple aspects in every dispatching decision. Since the typical short-term view of dispatching rules is one of the main limitations of such real-time assignment heuristics, we also incorporate in the multicriteria algorithm a specific heuristic rule that takes into account the empty-vehicle travel on a longer time-horizon. Moreover, we also adopt a genetic algorithm to tune the weights associated to each decision criteria in the global decision algorithm. The proposed approach is validated by means of a comparison with other dispatching rules, and with other recently proposed multicriteria dispatching strategies also based on computational Intelligence. The analysis of the results obtained by the proposed dispatching approach in both nominal and perturbed operating conditions (congestions, faults) confirms its effectiveness.
NASA Astrophysics Data System (ADS)
Mueller, Ulf Philipp; Wienholt, Lukas; Kleinhans, David; Cussmann, Ilka; Bunke, Wolf-Dieter; Pleßmann, Guido; Wendiggensen, Jochen
2018-02-01
There are several power grid modelling approaches suitable for simulations in the field of power grid planning. The restrictive policies of grid operators, regulators and research institutes concerning their original data and models lead to an increased interest in open source approaches of grid models based on open data. By including all voltage levels between 60 kV (high voltage) and 380kV (extra high voltage), we dissolve the common distinction between transmission and distribution grid in energy system models and utilize a single, integrated model instead. An open data set for primarily Germany, which can be used for non-linear, linear and linear-optimal power flow methods, was developed. This data set consists of an electrically parameterised grid topology as well as allocated generation and demand characteristics for present and future scenarios at high spatial and temporal resolution. The usability of the grid model was demonstrated by the performance of exemplary power flow optimizations. Based on a marginal cost driven power plant dispatch, being subject to grid restrictions, congested power lines were identified. Continuous validation of the model is nescessary in order to reliably model storage and grid expansion in progressing research.
Wind Generator & Biomass No-draft Gasification Hybrid
NASA Astrophysics Data System (ADS)
Hein, Matthew R.
The premise of this research is that underutilized but vast intermittent renewable energy resources, such as wind, can become more market competitive by coupling with storable renewable energy sources, like biomass; thereby creating a firm capacity resource. Specifically, the Midwest state of South Dakota has immense wind energy potential that is not used because of economic and logistic barriers of electrical transmission or storage. Coupling the state's intermittent wind resource with another of the state's energy resources, cellulosic non-food biomass, by using a wind generator and no-draft biomass gasification hybrid system will result in a energy source that is both firm and storable. The average energy content of common biomass feedstock was determined, 14.8 MJ/kg (7.153 Btu/lb), along with the assumed typical biomass conversion efficiency of the no-draft gasifier, 65%, so that an average electrical energy round trip efficiency (RTE) of 214% can be expected (i.e. One unit of wind electrical energy can produce 2.14 kWh of electrical energy stored as syngas.) from a wind generator and no-draft biomass gasification system. Wind characteristics are site specific so this analysis utilizes a synthetic wind resource to represent a statistically sound gross representation of South Dakota's wind regime based on data from the Wind Resource Assessment Network (WRAN) locations. A synthetic wind turbine generated from common wind turbine power curves and scaled to 1-MW rated capacity was utilized for this analysis in order to remove equipment bias from the results. A standard 8,760-hour BIN Analysis model was constructed within HOMER, powerful simulation software developed by the National Renewable Energy Laboratory (NREL) to model the performance of renewable power systems. It was found that the optimum configuration on a per-megawatt-transmitted basis required a wind generator (wind farm) rated capacity of 3-MW with an anticipated annual biomass feedstock of 26,132 GJ or an anticipated 1,766 tonnes of biomass. The levelized cost of electricity (COE) ranged from 65.6/GJ (236/MWh) to 208.9/GJ (752/MWh) with the price of generated electricity being most sensitive to the biomass feedstock cost and the levelized COE being significantly impacted by the high cost of compressed storage. The resulting electrical energy available to the grid has an approximate wholesale value of 13.5/GJ (48.6/MWh) based on year 2007 Midwest Reliability Organization (MRO) regional averages [1]. Therefore, the annual average wholesale value of the generated electricity is lower than the cost to produce the electricity. A significant deficiency of this simple comparison is that it does not consider the fact that the proposed wind and biomass gasification hybrid is now a dispatchable source of electricity with a near net-zero lifetime carbon footprint and storage capability. Dispatchable power can profit from market fluctuations that dramatically increase the value of available electricity so that in addition to providing base power the hybrid facility can store energy during low price points in the market and generate at full capacity during points of high prices. Any financial incentive for energy generated from reduced carbon technologies will also increase the value of electricity produced. Also, alternative operational parameters that do not require the costly storage of synthetic natural gas (SNG) will likely result in a more competitive levelized COE. Additional benefits of the system are in the flexibility of transporting wind and biomass energy produced as well as the end use of the energy. Instead of high-voltage electrical transmission a gas line can now be used to transport energy produced by the wind. Syngas can also be further processed into higher energy density liquefied syngas. Liquid fuels can then be transported via commercial freight on existing road infrastructure.
Flexible NO(x) abatement from power plants in the eastern United States.
Sun, Lin; Webster, Mort; McGaughey, Gary; McDonald-Buller, Elena C; Thompson, Tammy; Prinn, Ronald; Ellerman, A Denny; Allen, David T
2012-05-15
Emission controls that provide incentives for maximizing reductions in emissions of ozone precursors on days when ozone concentrations are highest have the potential to be cost-effective ozone management strategies. Conventional prescriptive emissions controls or cap-and-trade programs consider all emissions similarly regardless of when they occur, despite the fact that contributions to ozone formation may vary. In contrast, a time-differentiated approach targets emissions reductions on forecasted high ozone days without imposition of additional costs on lower ozone days. This work examines simulations of such dynamic air quality management strategies for NO(x) emissions from electric generating units. Results from a model of day-specific NO(x) pricing applied to the Pennsylvania-New Jersey-Maryland (PJM) portion of the northeastern U.S. electrical grid demonstrate (i) that sufficient flexibility in electricity generation is available to allow power production to be switched from high to low NO(x) emitting facilities, (ii) that the emission price required to induce EGUs to change their strategies for power generation are competitive with other control costs, (iii) that dispatching strategies, which can change the spatial and temporal distribution of emissions, lead to ozone concentration reductions comparable to other control technologies, and (iv) that air quality forecasting is sufficiently accurate to allow EGUs to adapt their power generation strategies.
Hardeland, Camilla; Olasveengen, Theresa M; Lawrence, Rob; Garrison, Danny; Lorem, Tonje; Farstad, Gunnar; Wik, Lars
2014-05-01
Prompt emergency medical service (EMS) system activation with rapid delivery of pre-hospital treatment is essential for patients suffering out-of-hospital cardiac arrest (OHCA). The two most commonly used dispatch tools are Medical Priority Dispatch (MPD) and Criteria Based Dispatch (CBD). We compared cardiac arrest call processing using these two dispatch tools in two different dispatch centres. Observational study of adult EMS confirmed (non-EMS witnessed) OHCA calls during one year in Richmond, USA (MPD) and Oslo, Norway (CBD). Patients receiving CPR prior to call, interrupted calls or calls where the caller did not have access to the patients were excluded from analysis. Dispatch logs, ambulance records and digitalized dispatcher and caller voice recordings were compared. The MPDS-site processed 182 cardiac arrest calls and the CBD-site 232, of which 100 and 140 calls met the inclusion criteria, respectively. The recognition of cardiac arrest was not different in the MPD and CBD systems; 82% vs. 77% (p=0.42), and pre-EMS arrival CPR instructions were offered to 81% vs. 74% (p=0.22) of callers, respectively. Time to ambulance dispatch was median (95% confidence interval) 15 (13, 17) vs. 33 (29, 36) seconds (p<0.001) and time to chest compression delivery; 4.3 (3.7, 4.9) vs. 3.7 (3.0, 4.1)min for the MPD and CBD systems, respectively (p=0.05). Pre-arrival CPR instructions were offered faster and more frequently in the CBD system, but in both systems chest compressions were delayed 3-4min. Earlier recognition of cardiac arrest and improved CPR instructions may facilitate earlier lay rescuer CPR. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Emergency medical dispatch : national standard curriculum ready
DOT National Transportation Integrated Search
1996-05-01
This Traffic Tech describes the recently updated "Emergency Medical Dispatch: National Standard Curriculum," which was developed in 1972. Emergency service providers use these uniform standards to develop or select an emergency medical dispatch progr...
New procedure speeds cold start, protects turbine
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mallard, R.E.; Jordan, C.A.
1995-09-01
System dispatch from today`s power plants must consider availability of purchase power (buy and sell), fuel prices, and unit availability and efficiency. To gain the best combination of these factors, steam units must be capable of quick removal and return to service. However, unit startups are expensive, time consuming nd operationally demanding. For example, excessive thermal stresses can be catastrophic to a unit. With those factors in mind, Jacksonville Electric Authority (JEA) developed the ``valve open start`` procedure described here.
17. VIEW OF ANCHOR BRIDGE NUMBER 310 LOOKING EAST ALONG ...
17. VIEW OF ANCHOR BRIDGE NUMBER 310 LOOKING EAST ALONG THE MAIN LINE TRACK LOCATED TO THE NORTH OF THE COS COB POWER PLANT. ANCHOR BRIDGES LOCATED AT TWO MILE INTERVALS WITHSTAND CATENARY TENSION AND PROVIDE A PLATFORM FOR MOUNTING OIL FILLED CIRCUIT BREAKERS, LIGHTNING ARRESTORS AND OTHER ELECTRICAL EQUIPMENT. THE ROOF OF THE LOAD DISPATCHER'S TOWER CAN BE SEEN DIRECTLY BEHIND THE RIGHT SIDE OF THE BRIDGE. - New York, New Haven & Hartford Railroad, Cos Cob Power Plant, Sound Shore Drive, Greenwich, Fairfield County, CT
Ambulance dispatches to schools during a 5-year period in Fukui Prefecture.
Takinami, Yoshikazu; Maeda, Shinji
2017-01-01
To determine the characteristics and trends of medical emergencies during school activities by analyzing information provided by fire departments. During a 5-year period from January 2009 to December 2013, all nine fire departments in Fukui Prefecture handled 850 emergencies at schools. We investigated the 850 cases with the age range of 0-63 years. It was found that 21.5% of ambulance dispatches to schools were on weekends and there were more dispatches for non-faculty members of all age groups on weekends than on weekdays. The percentage of weekend dispatches was particularly high for students aged ≥19 years. Emergency calls for junior high school students and younger students accounted for the majority of weekday calls. There were a total of 524 ambulance dispatches for the three categories "sprains, contusions, dislocations, and fractures" ( n = 245), "seizures, epilepsy, and syncope" ( n = 171), and "cuts, bruises, lacerations, trauma, amputations, and burns" ( n = 108), with dispatches for these three categories accounting for 61.6% of all dispatches. Almost all dispatches for "heat stroke and dehydration" were during school hours and were concentrated between the months of July and September. Heat stroke was most common among high school students and most often occurred during the summer/fall season and on weekends. Heat stroke was the fourth most frequent condition that required an ambulance dispatch after the above three conditions. Heat stroke is predictable, indicating that it is necessary to prevent heat stroke during high school club activities.
Optimal GENCO bidding strategy
NASA Astrophysics Data System (ADS)
Gao, Feng
Electricity industries worldwide are undergoing a period of profound upheaval. The conventional vertically integrated mechanism is being replaced by a competitive market environment. Generation companies have incentives to apply novel technologies to lower production costs, for example: Combined Cycle units. Economic dispatch with Combined Cycle units becomes a non-convex optimization problem, which is difficult if not impossible to solve by conventional methods. Several techniques are proposed here: Mixed Integer Linear Programming, a hybrid method, as well as Evolutionary Algorithms. Evolutionary Algorithms share a common mechanism, stochastic searching per generation. The stochastic property makes evolutionary algorithms robust and adaptive enough to solve a non-convex optimization problem. This research implements GA, EP, and PS algorithms for economic dispatch with Combined Cycle units, and makes a comparison with classical Mixed Integer Linear Programming. The electricity market equilibrium model not only helps Independent System Operator/Regulator analyze market performance and market power, but also provides Market Participants the ability to build optimal bidding strategies based on Microeconomics analysis. Supply Function Equilibrium (SFE) is attractive compared to traditional models. This research identifies a proper SFE model, which can be applied to a multiple period situation. The equilibrium condition using discrete time optimal control is then developed for fuel resource constraints. Finally, the research discusses the issues of multiple equilibria and mixed strategies, which are caused by the transmission network. Additionally, an advantage of the proposed model for merchant transmission planning is discussed. A market simulator is a valuable training and evaluation tool to assist sellers, buyers, and regulators to understand market performance and make better decisions. A traditional optimization model may not be enough to consider the distributed, large-scale, and complex energy market. This research compares the performance and searching paths of different artificial life techniques such as Genetic Algorithm (GA), Evolutionary Programming (EP), and Particle Swarm (PS), and look for a proper method to emulate Generation Companies' (GENCOs) bidding strategies. After deregulation, GENCOs face risk and uncertainty associated with the fast-changing market environment. A profit-based bidding decision support system is critical for GENCOs to keep a competitive position in the new environment. Most past research do not pay special attention to the piecewise staircase characteristic of generator offer curves. This research proposes an optimal bidding strategy based on Parametric Linear Programming. The proposed algorithm is able to handle actual piecewise staircase energy offer curves. The proposed method is then extended to incorporate incomplete information based on Decision Analysis. Finally, the author develops an optimal bidding tool (GenBidding) and applies it to the RTS96 test system.
NASA Astrophysics Data System (ADS)
Wang, Yan; Huang, Song; Ji, Zhicheng
2017-07-01
This paper presents a hybrid particle swarm optimization and gravitational search algorithm based on hybrid mutation strategy (HGSAPSO-M) to optimize economic dispatch (ED) including distributed generations (DGs) considering market-based energy pricing. A daily ED model was formulated and a hybrid mutation strategy was adopted in HGSAPSO-M. The hybrid mutation strategy includes two mutation operators, chaotic mutation, Gaussian mutation. The proposed algorithm was tested on IEEE-33 bus and results show that the approach is effective for this problem.
The impacts of meeting a tight CO2 performance standard on the electric power sector
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hanson, Donald; Schmalzer, David; Nichols, Christopher
This paper presents innovative modeling of complex interactions among gas-fired generators, coal-fired power plants, and renewables (wind and solar) when pushed hard to reduce CO2 emissions. A hypothetical CO2 technology performance standard, giving rise to a shadow price on CO2 emissions, was specified as part of the study design. In this work we see gas generation rapidly replacing coal generation. To understand the fate of coal based generation, it is important to examine trends at a granular level. An important feature of our model, the Electricity Supply and Investment Model (ESIM) is that it contains a unit inventory with unitmore » characteristics and a memory of how each unit is operated over time. Cycling damages that individual coal units incur are a function of cumulative wear and tear over time. The expected remaining life of a cycled coal unit will depend on the severity of the cycling and for how many years. Deteriorating operating characteristics of a cycled unit over time results in higher operating costs, slipping down the dispatch loading order, and hence an acceleration of cycling damage, that is, a viscous circle of decline. The rate of CFPP retirements will increase for lower gas prices, higher price on CO2 emissions, and greater penetration of variable and intermittent renewables. Published by Elsevier B.V.« less
Analysis of Carbon Policies for Electricity Networks with High Penetration of Green Generation
NASA Astrophysics Data System (ADS)
Feijoo, Felipe A.
In recent decades, climate change has become one of the most crucial challenges for humanity. Climate change has a direct correlation with global warming, caused mainly by the green house gas emissions (GHG). The Environmental Protection Agency in the U.S. (EPA) attributes carbon dioxide to account for approximately 82% of the GHG emissions. Unfortunately, the energy sector is the main producer of carbon dioxide, with China and the U.S. as the highest emitters. Therefore, there is a strong (positive) correlation between energy production, global warming, and climate change. Stringent carbon emissions reduction targets have been established in order to reduce the impacts of GHG. Achieving these emissions reduction goals will require implementation of policies like as cap-and-trade and carbon taxes, together with transformation of the electricity grid into a smarter system with high green energy penetration. However, the consideration of policies solely in view of carbon emissions reduction may adversely impact other market outcomes such as electricity prices and consumption. In this dissertation, a two-layer mathematical-statistical framework is presented, that serves to develop carbon policies to reduce emissions level while minimizing the negative impacts on other market outcomes. The bottom layer of the two layer model comprises a bi-level optimization problem. The top layer comprises a statistical model and a Pareto analysis. Two related but different problems are studied under this methodology. The first problem looks into the design of cap-and-trade policies for deregulated electricity markets that satisfy the interest of different market constituents. Via the second problem, it is demonstrated how the framework can be used to obtain levels of carbon emissions reduction while minimizing the negative impact on electricity demand and maximizing green penetration from microgrids. In the aforementioned studies, forecasts for electricity prices and production cost are considered. This, this dissertation also presents anew forecast model that can be easily integrated in the two-layer framework. It is demonstrated in this dissertation that the proposed framework can be utilized by policy-makers, power companies, consumers, and market regulators in developing emissions policy decisions, bidding strategies, market regulations, and electricity dispatch strategies.
Basta, Yara L; Zwetsloot, Inez M; Klinkenbijl, Jean H G; Rohof, Thomas; Monster, Mathijs M C; Fockens, Paul; Tytgat, Kristien M A J
2016-10-01
Timely communication is important to ensure high-quality health care. To facilitate this, the Gastro Intestinal Oncology Center Amsterdam (GIOCA) stipulated to dispatch medical reports on the day of the patient's visit. However, with the increasing number of patients, administrative processes at GIOCA were under pressure, and this standard was not met for the majority of patients. The aim and objective of this study was to dispatch 90% of medical reports on the day of the patient's visit by improving the logistic process. To assess the main causes for a prolonged dispatch time and to design improvements actions, the roadmap offered by Lean Six Sigma (LSS) was used, consisting of five phases: Define, Measure, Analyze, Improve and Control (DMAIC roadmap). Initially, 12.3% of the reports were dispatched on the day of the patient's visit. Three causes for a prolonged dispatch time were identified: (1) determining which doctors involved with treatment would compose the report; (2) the reports composed by a senior resident had to be reviewed by a medical specialist; and (3) a medical specialist had to authorize the administration to dispatch the reports. To circumvent these causes, a digital form was implemented in the electronic medical record that could be completed during the multidisciplinary team meeting. After implementation, 90.6% of the reports were dispatched on the day of the visit. The dispatch time of reports sent from hospital to primary care can be significantly reduced using Lean Six Sigma, improving the communication between hospital and primary care. © 2016 John Wiley & Sons, Ltd.
Training requirements for railroad dispatchers : objectives, syllabi and test designs
DOT National Transportation Integrated Search
1998-11-01
This report presents the results of a study to develop railroad dispatcher training objectives, syllabi for three types of training programs and test designs for the three programs. Information about current railroad dispatching methods and training ...
Optimizing Staffing levels and Schedules for Railroad Dispatching Centers
DOT National Transportation Integrated Search
2004-09-01
This report presents the results of a study to explore approaches to establishing staffing levels and schedules for railroad dispatchers. The : work was conducted as follow-up to a prior study that found fatigue among dispatchers, particularly those ...
Optimal Real-time Dispatch for Integrated Energy Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Firestone, Ryan Michael
This report describes the development and application of a dispatch optimization algorithm for integrated energy systems (IES) comprised of on-site cogeneration of heat and electricity, energy storage devices, and demand response opportunities. This work is intended to aid commercial and industrial sites in making use of modern computing power and optimization algorithms to make informed, near-optimal decisions under significant uncertainty and complex objective functions. The optimization algorithm uses a finite set of randomly generated future scenarios to approximate the true, stochastic future; constraints are included that prevent solutions to this approximate problem from deviating from solutions to the actual problem.more » The algorithm is then expressed as a mixed integer linear program, to which a powerful commercial solver is applied. A case study of United States Postal Service Processing and Distribution Centers (P&DC) in four cities and under three different electricity tariff structures is conducted to (1) determine the added value of optimal control to a cogeneration system over current, heuristic control strategies; (2) determine the value of limited electric load curtailment opportunities, with and without cogeneration; and (3) determine the trade-off between least-cost and least-carbon operations of a cogeneration system. Key results for the P&DC sites studied include (1) in locations where the average electricity and natural gas prices suggest a marginally profitable cogeneration system, optimal control can add up to 67% to the value of the cogeneration system; optimal control adds less value in locations where cogeneration is more clearly profitable; (2) optimal control under real-time pricing is (a) more complicated than under typical time-of-use tariffs and (b) at times necessary to make cogeneration economic at all; (3) limited electric load curtailment opportunities can be more valuable as a compliment to the cogeneration system than alone; and (4) most of the trade-off between least-cost and least-carbon IES is determined during the system design stage; for the IES system considered, there is little difference between least-cost control and least-carbon control.« less
Clegg, Gareth R; Lyon, Richard M; James, Scott; Branigan, Holly P; Bard, Ellen G; Egan, Gerry J
2014-01-01
Survival from out-of-hospital cardiac arrest (OHCA) is dependent on the chain of survival. Early recognition of cardiac arrest and provision of bystander cardiopulmonary resuscitation (CPR) are key determinants of OHCA survival. Emergency medical dispatchers play a key role in cardiac arrest recognition and giving telephone CPR advice. The interaction between caller and dispatcher can influence the time to bystander CPR and quality of resuscitation. We sought to pilot the use of emergency call transcription to audit and evaluate the holdups in performing dispatch-assisted CPR. A retrospective case selection of 50 consecutive suspected OHCA was performed. Audio recordings of calls were downloaded from the emergency medical dispatch centre computer database. All calls were transcribed using proprietary software and voice dialogue was compared with the corresponding stage on the Medical Priority Dispatch System (MPDS). Time to progress through each stage and number of caller-dispatcher interactions were calculated. Of the 50 downloaded calls, 47 were confirmed cases of OHCA. Call transcription was successfully completed for all OHCA calls. Bystander CPR was performed in 39 (83%) of these. In the remaining cases, the caller decided the patient was beyond help (n = 7) or the caller said that they were physically unable to perform CPR (n = 1). MPDS stages varied substantially in time to completion. Stage 9 (determining if the patient is breathing through airway instructions) took the longest time to complete (median = 59 s, IQR 22-82 s). Stage 11 (giving CPR instructions) also took a relatively longer time to complete compared to the other stages (median = 46 s, IQR 37-75 s). Stage 5 (establishing the patient's age) took the shortest time to complete (median = 5.5s, IQR 3-9s). Transcription of OHCA emergency calls and caller-dispatcher interaction compared to MPDS stage is feasible. Confirming whether a patient is breathing and completing CPR instructions required the longest time and most interactions between caller and dispatcher. Use of call transcription has the potential to identify key factors in caller-dispatcher interaction that could improve time to CPR and further research is warranted in this area. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Scheduling revisited workstations in integrated-circuit fabrication
NASA Technical Reports Server (NTRS)
Kline, Paul J.
1992-01-01
The cost of building new semiconductor wafer fabrication factories has grown rapidly, and a state-of-the-art fab may cost 250 million dollars or more. Obtaining an acceptable return on this investment requires high productivity from the fabrication facilities. This paper describes the Photo Dispatcher system which was developed to make machine-loading recommendations on a set of key fab machines. Dispatching policies that generally perform well in job shops (e.g., Shortest Remaining Processing Time) perform poorly for workstations such as photolithography which are visited several times by the same lot of silicon wafers. The Photo Dispatcher evaluates the history of workloads throughout the fab and identifies bottleneck areas. The scheduler then assigns priorities to lots depending on where they are headed after photolithography. These priorities are designed to avoid starving bottleneck workstations and to give preference to lots that are headed to areas where they can be processed with minimal waiting. Other factors considered by the scheduler to establish priorities are the nearness of a lot to the end of its process flow and the time that the lot has already been waiting in queue. Simulations that model the equipment and products in one of Texas Instrument's wafer fabs show the Photo Dispatcher can produce a 10 percent improvement in the time required to fabricate integrated circuits.
A modeling comparison of deep greenhouse gas emissions reduction scenarios by 2030 in California
Yeh, Sonia; Yang, Christopher; Gibbs, Michael; ...
2016-10-21
California aims to reduce greenhouse gas (GHG) emissions to 40% below 1990 levels by 2030. We compare six energy models that have played various roles in informing the state policymakers in setting climate policy goals and targets. These models adopt a range of modeling structures, including stock-turnover back-casting models, a least-cost optimization model, macroeconomic/macro-econometric models, and an electricity dispatch model. Results from these models provide useful insights in terms of the transformations in the energy system required, including efficiency improvements in cars, trucks, and buildings, electrification of end-uses, low- or zero-carbon electricity and fuels, aggressive adoptions of zero-emission vehicles (ZEVs),more » demand reduction, and large reductions of non-energy GHG emissions. Some of these studies also suggest that the direct economic costs can be fairly modest or even generate net savings, while the indirect macroeconomic benefits are large, as shifts in employment and capital investments could have higher economic returns than conventional energy expenditures. These models, however, often assume perfect markets, perfect competition, and zero transaction costs. They also do not provide specific policy guidance on how these transformative changes can be achieved. Greater emphasis on modeling uncertainty, consumer behaviors, heterogeneity of impacts, and spatial modeling would further enhance policymakers' ability to design more effective and targeted policies. Here, this paper presents an example of how policymakers, energy system modelers and stakeholders interact and work together to develop and evaluate long-term state climate policy targets. Lastly, even though this paper focuses on California, the process of dialogue and interactions, modeling results, and lessons learned can be generally adopted across different regions and scales.« less
Understanding how train dispatchers manage and control trains : results of a cognitive task analysis
DOT National Transportation Integrated Search
2001-05-01
This report documents the results of a Cognitive Task Analysis that examined how experienced railroad dispatchers manage and : schedule trains in todays environment. The objective was to understand the cognitive demands placed on railroad dispatch...
Understanding how train dispatchers manage and control trains : results of a cognitive task analysis
DOT National Transportation Integrated Search
2001-05-01
This report documents the results ofaCognitive Task Analysis that examined how experienced railroad dispatchers manage and : schedule trains in today's environment. The objective was to understand the cognitive demands placed on railroad dispatchers ...
DOT National Transportation Integrated Search
2001-05-01
This report documents the results of a Cognitive Task Analysis that examined how experienced railroad dispatchers manage and schedule trains in todays environment. The objective was to understand the cognitive demands placed on railroad dispatcher...
Schmid, Verena
2012-01-01
Emergency service providers are supposed to locate ambulances such that in case of emergency patients can be reached in a time-efficient manner. Two fundamental decisions and choices need to be made real-time. First of all immediately after a request emerges an appropriate vehicle needs to be dispatched and send to the requests’ site. After having served a request the vehicle needs to be relocated to its next waiting location. We are going to propose a model and solve the underlying optimization problem using approximate dynamic programming (ADP), an emerging and powerful tool for solving stochastic and dynamic problems typically arising in the field of operations research. Empirical tests based on real data from the city of Vienna indicate that by deviating from the classical dispatching rules the average response time can be decreased from 4.60 to 4.01 minutes, which corresponds to an improvement of 12.89%. Furthermore we are going to show that it is essential to consider time-dependent information such as travel times and changes with respect to the request volume explicitly. Ignoring the current time and its consequences thereafter during the stage of modeling and optimization leads to suboptimal decisions. PMID:25540476
14 CFR 121.533 - Responsibility for operational control: Domestic operations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...
14 CFR 121.533 - Responsibility for operational control: Domestic operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...
14 CFR 121.533 - Responsibility for operational control: Domestic operations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...
14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.
Code of Federal Regulations, 2011 CFR
2011-01-01
... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...
14 CFR 121.533 - Responsibility for operational control: Domestic operations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...
14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.
Code of Federal Regulations, 2012 CFR
2012-01-01
... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...
14 CFR 121.533 - Responsibility for operational control: Domestic operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations... aircraft dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in compliance with this chapter and operations specifications. (c) The aircraft dispatcher is...
14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.
Code of Federal Regulations, 2013 CFR
2013-01-01
... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...
14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.
Code of Federal Regulations, 2010 CFR
2010-01-01
... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...
14 CFR 121.422 - Aircraft dispatchers: Initial and transition ground training.
Code of Federal Regulations, 2014 CFR
2014-01-01
... computations; (iv) Basic airplane performance dispatch requirements and procedures; (v) Flight planning including track selection, flight time analysis, and fuel requirements; and (vi) Emergency procedures. (3... procedures, and other subjects having a bearing on dispatcher duties and responsibilities; (ii) Flight...
Fredman, David; Svensson, Leif; Ban, Yifang; Jonsson, Martin; Hollenberg, Jacob; Nordberg, Per; Ringh, Mattias; Rosenqvist, Mårten; Lundén, Margareta; Claesson, Andreas
2016-10-01
Early use of automated external defibrillators (AED) increases survival in cases of out-of-hospital cardiac arrest (OHCA). Dispatchers play important roles in identifying OHCA, dispatching ambulances and providing callers with telephone-assisted cardiopulmonary resuscitation. Guidelines recommend that AED registries be linked to dispatch centres as tools to refer callers to nearby AED. The aim of this study was to investigate to what extent dispatchers, when provided with a tool to display AED locations and accessibility, referred callers to nearby AED. An application providing real-time visualization of AED locations and accessibility was implemented at four dispatch centres in Sweden. Dispatchers were instructed to refer callers to nearby AED when OHCA was suspected. Such cases were prospectively collected, and geographic information systems were used to identify those located ≤100m from an AED. Audio recordings of emergency calls were assessed to evaluate the AED referral rate. Between February and August 2014, 3009 suspected OHCA calls were received. In 6.6% of those calls (200/3009), an AED was ≤100m from the suspected OHCA. The AED was accessible and the caller was not alone on scene in 24% (47/200) of these cases. In two of those 47 cases (4.3%), the dispatcher referred the caller to the AED. Despite a tool for dispatchers to refer callers to a nearby AED, referral was rare. Only a minority of the suspected OHCA cases occurred ≤100m from an AED. We identified AED accessibility and callers being alone on scene as obstacles for AED referral. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Rawshani, Araz; Rawshani, Nina; Gelang, Carita; Andersson, Jan-Otto; Larsson, Anna; Bång, Angela; Herlitz, Johan; Gellerstedt, Martin
2017-06-01
We examined the accuracy in assessments of emergency dispatchers according to their education and time of the day. We examined this in chest pain patients who were diagnosed with a potentially life-threatening condition (LTC) or died within 30days. Among 2205 persons, 482 died, 1631 experienced an acute coronary syndrome (ACS), 1914 had a LTC. Multivariable logistic regression was used to study how time of the call and the dispatcher's education were associated with the risk of missing to give priority 1 (the highest). Among patients who died, a 7-fold increase in odds of missing to give priority 1 was noted at 1.00pm, as compared with midnight. Compared with assistant nurses, odds ratio for dispatchers with no (medical) training was 0.34 (95% CI 0.14 to 0.77). Among patients with an ACS, odds ratio for calls arriving before lunch was 2.02 (95% CI 1.22 to 3.43), compared with midnight. Compared with assistant nurses, odds ratio for operators with no training was 0.23 (95% CI 0.13 to 0.40). Similar associations were noted for those with any LTC. Dispatcher's education was not associated with the patient's survival. In this group of patients, which experience substantial mortality and morbidity, the risk of not obtaining highest dispatch priority was increased up to 7-fold during lunchtime. Dispatch operators without medical education had the lowest risk, compared with nurses and assistant nurses, of missing to give priority 1, at the expense of lower positive predictive value. What is already known about this subject? Use of the emergency medical service (EMS) increases survival among patients with acute coronary syndromes. It is unknown whether the efficiency - as judged by the ability to identify life-threatening cases among patients with chest pain - varies according to the dispatcher's educational level and the time of day. What does this study add? We provide evidence that the dispatcher's education does not influence survival among patients calling the EMS due to chest discomfort. However, medically educated dispatchers are at greatest risk of missing to identify life-threatening cases, which is explained by more parsimonious use of the highest dispatch priority. We also show that the risk of missing life-threatening cases is at highest around lunch time. How might this impact on clinical practice? Dispatch centers are operated differently all over the world and chest discomfort is one of the most frequent symptoms encountered; we provide evidence that it is safe to operate a dispatch center without medically trained personnel, who actually miss fewer cases of acute coronary syndromes. However, non-medically trained dispatchers consume more pre-hospital resources. Copyright © 2017 Elsevier B.V. All rights reserved.
The method of a joint intraday security check system based on cloud computing
NASA Astrophysics Data System (ADS)
Dong, Wei; Feng, Changyou; Zhou, Caiqi; Cai, Zhi; Dan, Xu; Dai, Sai; Zhang, Chuancheng
2017-01-01
The intraday security check is the core application in the dispatching control system. The existing security check calculation only uses the dispatch center’s local model and data as the functional margin. This paper introduces the design of all-grid intraday joint security check system based on cloud computing and its implementation. To reduce the effect of subarea bad data on the all-grid security check, a new power flow algorithm basing on comparison and adjustment with inter-provincial tie-line plan is presented. And the numerical example illustrated the effectiveness and feasibility of the proposed method.
Solar thermal power & gas turbine hybrid design with molten salt storage tank
NASA Astrophysics Data System (ADS)
Martín, Fernando; Wiesenberg, Ralf; Santana, Domingo
2017-06-01
Taking into consideration the need to decelerate the global climatic change, power generation has to shift from burning fossil fuel to renewable energy source in short medium period of time. In this work, we are presenting a new model of a solar-gas natural hybrid power cycle with the main aim of decoupling the solar generation system from the gas turbine system. The objective is to have high solar power contribution compared to conventional ISCC plants [2], producing firm and dispatchable electricity at the same time. The decoupling is motivated by the low solar contribution reached by the ISCC, which is technically limited to maximum of 15%, [4]. In our case, we have implemented a solar tower with molten salts as working fluid. Central receiver systems get higher performance than others systems, like parabolic trough technology [1], due to the higher temperature achieved in the heat transferred fluid HTF, close to 560°C.
14 CFR 121.463 - Aircraft dispatcher qualifications.
Code of Federal Regulations, 2010 CFR
2010-01-01
... aircraft dispatcher for a particular airplane group unless that person has, with respect to an airplane of that group, satisfactorily completed the following: (1) Initial dispatcher training, except that a person who has satisfactorily completed such training for another type airplane of the same group need...
Real-Time Dispatch of Petroleum Tank Trucks.
1979-12-01
dispatches for each bulk terminal from which loads are hauled. The dispatchers, located at a central national order processing facility, must each...of an order processor and new capa- bilities to, for instance, trace orders. Also, uniform control of thef order processing function is desirable, if
14 CFR 121.415 - Crewmember and dispatcher training requirements.
Code of Federal Regulations, 2010 CFR
2010-01-01
... indoctrination ground training for newly hired crewmembers or dispatchers including 40 programmed hours of... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Crewmember and dispatcher training... OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Training Program § 121.415 Crewmember...
Influence of dispatching rules on average production lead time for multi-stage production systems.
Hübl, Alexander; Jodlbauer, Herbert; Altendorfer, Klaus
2013-08-01
In this paper the influence of different dispatching rules on the average production lead time is investigated. Two theorems based on covariance between processing time and production lead time are formulated and proved theoretically. Theorem 1 links the average production lead time to the "processing time weighted production lead time" for the multi-stage production systems analytically. The influence of different dispatching rules on average lead time, which is well known from simulation and empirical studies, can be proved theoretically in Theorem 2 for a single stage production system. A simulation study is conducted to gain more insight into the influence of dispatching rules on average production lead time in a multi-stage production system. We find that the "processing time weighted average production lead time" for a multi-stage production system is not invariant of the applied dispatching rule and can be used as a dispatching rule independent indicator for single-stage production systems.
NASA Astrophysics Data System (ADS)
Tarroja, Brian; Eichman, Joshua D.; Zhang, Li; Brown, Tim M.; Samuelsen, Scott
2015-03-01
A study has been performed that analyzes the effectiveness of utilizing plug-in vehicles to meet holistic environmental goals across the combined electricity and transportation sectors. In this study, plug-in hybrid electric vehicle (PHEV) penetration levels are varied from 0 to 60% and base renewable penetration levels are varied from 10 to 63%. The first part focused on the effect of installing plug-in hybrid electric vehicles on the environmental performance of the combined electricity and transportation sectors. The second part addresses impacts on the design and operation of load-balancing resources on the electric grid associated with fleet capacity factor, peaking and load-following generator capacity, efficiency, ramp rates, start-up events and the levelized cost of electricity. PHEVs using smart charging are found to counteract many of the disruptive impacts of intermittent renewable power on balancing generators for a wide range of renewable penetration levels, only becoming limited at high renewable penetration levels due to lack of flexibility and finite load size. This study highlights synergy between sustainability measures in the electric and transportation sectors and the importance of communicative dispatch of these vehicles.
Distributed Economic Dispatch in Microgrids Based on Cooperative Reinforcement Learning.
Liu, Weirong; Zhuang, Peng; Liang, Hao; Peng, Jun; Huang, Zhiwu; Weirong Liu; Peng Zhuang; Hao Liang; Jun Peng; Zhiwu Huang; Liu, Weirong; Liang, Hao; Peng, Jun; Zhuang, Peng; Huang, Zhiwu
2018-06-01
Microgrids incorporated with distributed generation (DG) units and energy storage (ES) devices are expected to play more and more important roles in the future power systems. Yet, achieving efficient distributed economic dispatch in microgrids is a challenging issue due to the randomness and nonlinear characteristics of DG units and loads. This paper proposes a cooperative reinforcement learning algorithm for distributed economic dispatch in microgrids. Utilizing the learning algorithm can avoid the difficulty of stochastic modeling and high computational complexity. In the cooperative reinforcement learning algorithm, the function approximation is leveraged to deal with the large and continuous state spaces. And a diffusion strategy is incorporated to coordinate the actions of DG units and ES devices. Based on the proposed algorithm, each node in microgrids only needs to communicate with its local neighbors, without relying on any centralized controllers. Algorithm convergence is analyzed, and simulations based on real-world meteorological and load data are conducted to validate the performance of the proposed algorithm.
14 CFR 121.404 - Compliance dates: Crew and dispatcher resource management training.
Code of Federal Regulations, 2010 CFR
2010-01-01
... approved crew resource management (CRM) or dispatcher resource management (DRM) initial training, as... resource management training. 121.404 Section 121.404 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... § 121.404 Compliance dates: Crew and dispatcher resource management training. After March 19, 1998, no...
14 CFR 121.687 - Dispatch release: Flag and domestic operations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 3 2014-01-01 2014-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...
14 CFR 121.687 - Dispatch release: Flag and domestic operations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 3 2013-01-01 2013-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...
14 CFR 121.687 - Dispatch release: Flag and domestic operations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 3 2012-01-01 2012-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...
14 CFR 121.687 - Dispatch release: Flag and domestic operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 3 2011-01-01 2011-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...
14 CFR 121.687 - Dispatch release: Flag and domestic operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Dispatch release: Flag and domestic operations. 121.687 Section 121.687 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF...) The dispatch release must contain, or have attached to it, weather reports, available weather...
NASA Astrophysics Data System (ADS)
Xiao, Jingjie
A key hurdle for implementing real-time pricing of electricity is a lack of consumers' responses. Solutions to overcome the hurdle include the energy management system that automatically optimizes household appliance usage such as plug-in hybrid electric vehicle charging (and discharging with vehicle-to-grid) via a two-way communication with the grid. Real-time pricing, combined with household automation devices, has a potential to accommodate an increasing penetration of plug-in hybrid electric vehicles. In addition, the intelligent energy controller on the consumer-side can help increase the utilization rate of the intermittent renewable resource, as the demand can be managed to match the output profile of renewables, thus making the intermittent resource such as wind and solar more economically competitive in the long run. One of the main goals of this dissertation is to present how real-time retail pricing, aided by control automation devices, can be integrated into the wholesale electricity market under various uncertainties through approximate dynamic programming. What distinguishes this study from the existing work in the literature is that whole- sale electricity prices are endogenously determined as we solve a system operator's economic dispatch problem on an hourly basis over the entire optimization horizon. This modeling and algorithm framework will allow a feedback loop between electricity prices and electricity consumption to be fully captured. While we are interested in a near-optimal solution using approximate dynamic programming; deterministic linear programming benchmarks are use to demonstrate the quality of our solutions. The other goal of the dissertation is to use this framework to provide numerical evidence to the debate on whether real-time pricing is superior than the current flat rate structure in terms of both economic and environmental impacts. For this purpose, the modeling and algorithm framework is tested on a large-scale test case with hundreds of power plants based on data available for California, making our findings useful for policy makers, system operators and utility companies to gain a concrete understanding on the scale of the impact with real-time pricing.
Staid, Andrea; Watson, Jean -Paul; Wets, Roger J. -B.; ...
2017-07-11
Forecasts of available wind power are critical in key electric power systems operations planning problems, including economic dispatch and unit commitment. Such forecasts are necessarily uncertain, limiting the reliability and cost effectiveness of operations planning models based on a single deterministic or “point” forecast. A common approach to address this limitation involves the use of a number of probabilistic scenarios, each specifying a possible trajectory of wind power production, with associated probability. We present and analyze a novel method for generating probabilistic wind power scenarios, leveraging available historical information in the form of forecasted and corresponding observed wind power timemore » series. We estimate non-parametric forecast error densities, specifically using epi-spline basis functions, allowing us to capture the skewed and non-parametric nature of error densities observed in real-world data. We then describe a method to generate probabilistic scenarios from these basis functions that allows users to control for the degree to which extreme errors are captured.We compare the performance of our approach to the current state-of-the-art considering publicly available data associated with the Bonneville Power Administration, analyzing aggregate production of a number of wind farms over a large geographic region. Finally, we discuss the advantages of our approach in the context of specific power systems operations planning problems: stochastic unit commitment and economic dispatch. Here, our methodology is embodied in the joint Sandia – University of California Davis Prescient software package for assessing and analyzing stochastic operations strategies.« less
Quantifying the Economic and Grid Reliability Impacts of Improved Wind Power Forecasting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Qin; Martinez-Anido, Carlo Brancucci; Wu, Hongyu
Wind power forecasting is an important tool in power system operations to address variability and uncertainty. Accurately doing so is important to reducing the occurrence and length of curtailment, enhancing market efficiency, and improving the operational reliability of the bulk power system. This research quantifies the value of wind power forecasting improvements in the IEEE 118-bus test system as modified to emulate the generation mixes of Midcontinent, California, and New England independent system operator balancing authority areas. To measure the economic value, a commercially available production cost modeling tool was used to simulate the multi-timescale unit commitment (UC) and economicmore » dispatch process for calculating the cost savings and curtailment reductions. To measure the reliability improvements, an in-house tool, FESTIV, was used to calculate the system's area control error and the North American Electric Reliability Corporation Control Performance Standard 2. The approach allowed scientific reproducibility of results and cross-validation of the tools. A total of 270 scenarios were evaluated to accommodate the variation of three factors: generation mix, wind penetration level, and wind fore-casting improvements. The modified IEEE 118-bus systems utilized 1 year of data at multiple timescales, including the day-ahead UC, 4-hour-ahead UC, and 5-min real-time dispatch. The value of improved wind power forecasting was found to be strongly tied to the conventional generation mix, existence of energy storage devices, and the penetration level of wind energy. The simulation results demonstrate that wind power forecasting brings clear benefits to power system operations.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Staid, Andrea; Watson, Jean -Paul; Wets, Roger J. -B.
Forecasts of available wind power are critical in key electric power systems operations planning problems, including economic dispatch and unit commitment. Such forecasts are necessarily uncertain, limiting the reliability and cost effectiveness of operations planning models based on a single deterministic or “point” forecast. A common approach to address this limitation involves the use of a number of probabilistic scenarios, each specifying a possible trajectory of wind power production, with associated probability. We present and analyze a novel method for generating probabilistic wind power scenarios, leveraging available historical information in the form of forecasted and corresponding observed wind power timemore » series. We estimate non-parametric forecast error densities, specifically using epi-spline basis functions, allowing us to capture the skewed and non-parametric nature of error densities observed in real-world data. We then describe a method to generate probabilistic scenarios from these basis functions that allows users to control for the degree to which extreme errors are captured.We compare the performance of our approach to the current state-of-the-art considering publicly available data associated with the Bonneville Power Administration, analyzing aggregate production of a number of wind farms over a large geographic region. Finally, we discuss the advantages of our approach in the context of specific power systems operations planning problems: stochastic unit commitment and economic dispatch. Here, our methodology is embodied in the joint Sandia – University of California Davis Prescient software package for assessing and analyzing stochastic operations strategies.« less
Research on intelligent power consumption strategy based on time-of-use pricing
NASA Astrophysics Data System (ADS)
Fu, Wei; Gong, Li; Chen, Heli; He, Yu
2017-06-01
In this paper, through the analysis of shortcomings of the current domestic and foreign household power consumption strategy: Passive way of power consumption, ignoring the different priority of electric equipment, neglecting the actual load pressure of the grid, ignoring the interaction with the user, to decrease the peak-valley difference and improve load curve in residential area by demand response (DR technology), an intelligent power consumption scheme based on time-of-use(TOU) pricing for household appliances is proposed. The main contribution of this paper is: (1) Three types of household appliance loads are abstracted from different operating laws of various household appliances, and the control models and DR strategies corresponding to these types are established. (2) The fuzzified processing for the information of TOU price, which is based on the time intervals, is performed to get the price priority, in accordance with such DR events as the maximum restricted load of DR, the time of DR and the duration of interruptible load and so on, the DR control rule and pre-scheduling mechanism are led in. (3) The dispatching sequence of household appliances in the control and scheduling queue are switched and controlled to implement the equilibrium of peak and valley loads. The equilibrium effects and economic benefits of power system by pre-scheduling and DR dispatching are compared and analyzed by simulation example, and the results show that using the proposed household appliance control (HAC) scheme the overall cost of consumers can be reduced and the power system load can be alleviated, so the proposed household appliance control (HAC) scheme is feasible and reasonable.
49 CFR 1242.57 - Dispatching trains (account XX-51-58).
Code of Federal Regulations, 2010 CFR
2010-10-01
... 49 Transportation 9 2010-10-01 2010-10-01 false Dispatching trains (account XX-51-58). 1242.57 Section 1242.57 Transportation Other Regulations Relating to Transportation (Continued) SURFACE...-Transportation § 1242.57 Dispatching trains (account XX-51-58). Separate common expenses on the basis of train...
14 CFR 65.61 - Aircraft dispatcher certification courses: Content and minimum hours.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Aircraft dispatcher certification courses: Content and minimum hours. 65.61 Section 65.61 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aircraft dispatcher certification course must: (1) Provide instruction in the areas of knowledge and topics...
14 CFR 65.61 - Aircraft dispatcher certification courses: Content and minimum hours.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Aircraft dispatcher certification courses: Content and minimum hours. 65.61 Section 65.61 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION... aircraft dispatcher certification course must: (1) Provide instruction in the areas of knowledge and topics...
Heat Transfer Search Algorithm for Non-convex Economic Dispatch Problems
NASA Astrophysics Data System (ADS)
Hazra, Abhik; Das, Saborni; Basu, Mousumi
2018-06-01
This paper presents Heat Transfer Search (HTS) algorithm for the non-linear economic dispatch problem. HTS algorithm is based on the law of thermodynamics and heat transfer. The proficiency of the suggested technique has been disclosed on three dissimilar complicated economic dispatch problems with valve point effect; prohibited operating zone; and multiple fuels with valve point effect. Test results acquired from the suggested technique for the economic dispatch problem have been fitted to that acquired from other stated evolutionary techniques. It has been observed that the suggested HTS carry out superior solutions.
Heat Transfer Search Algorithm for Non-convex Economic Dispatch Problems
NASA Astrophysics Data System (ADS)
Hazra, Abhik; Das, Saborni; Basu, Mousumi
2018-03-01
This paper presents Heat Transfer Search (HTS) algorithm for the non-linear economic dispatch problem. HTS algorithm is based on the law of thermodynamics and heat transfer. The proficiency of the suggested technique has been disclosed on three dissimilar complicated economic dispatch problems with valve point effect; prohibited operating zone; and multiple fuels with valve point effect. Test results acquired from the suggested technique for the economic dispatch problem have been fitted to that acquired from other stated evolutionary techniques. It has been observed that the suggested HTS carry out superior solutions.
A priority dispatch system for emergency medical services.
Slovis, C M; Carruth, T B; Seitz, W J; Thomas, C M; Elsea, W R
1985-11-01
A decision tree priority dispatch system for emergency medical services (EMS) was developed and implemented in Atlanta and Fulton County, Georgia. The dispatch system shortened the average response time from 14.2 minutes to 10.4 minutes for the 30% of patients deemed most urgent (P less than or equal to .05); resulted in a significant increase in the use of advanced life support units for this group (P less than or equal to .02); decreased the number of calls that required a backup ambulance service; and significantly increased conformity to national EMS response time standards for critically ill and injured patients (P less than or equal to .0009). Due to dispatch error, 0.3% of calls were dispatched as least severe but subsequently were found to be most urgent.
NASA Astrophysics Data System (ADS)
O'Connell, M.; Macknick, J.; Voisin, N.; Fu, T.
2017-12-01
The western US electric grid is highly dependent upon water resources for reliable operation. Hydropower and water-cooled thermoelectric technologies represent 67% of generating capacity in the western region of the US. While water resources provide a significant amount of generation and reliability for the grid, these same resources can represent vulnerabilities during times of drought or low flow conditions. A lack of water affects water-dependent technologies and can result in more expensive generators needing to run in order to meet electric grid demand, resulting in higher electricity prices and a higher cost to operate the grid. A companion study assesses the impact of changes in water availability and air temperatures on power operations by directly derating hydro and thermo-electric generators. In this study we assess the sensitivities and tipping points of water availability compared with higher fuel prices in electricity sector operations. We evaluate the impacts of varying electricity prices by modifying fuel prices for coal and natural gas. We then analyze the difference in simulation results between changes in fuel prices in combination with water availability and air temperature variability. We simulate three fuel price scenarios for a 2010 baseline scenario along with 100 historical and future hydro-climate conditions. We use the PLEXOS electricity production cost model to optimize power system dispatch and cost decisions under each combination of fuel price and water constraint. Some of the metrics evaluated are total production cost, generation type mix, emissions, transmission congestion, and reserve procurement. These metrics give insight to how strained the system is, how much flexibility it still has, and to what extent water resource availability or fuel prices drive changes in the electricity sector operations. This work will provide insights into current electricity operations as well as future cases of increased penetration of variable renewable generation technologies such as wind and solar.
Impacts of demand response and renewable generation in electricity power market
NASA Astrophysics Data System (ADS)
Zhao, Zhechong
This thesis presents the objective of the research which is to analyze the impacts of uncertain wind power and demand response on power systems operation and power market clearing. First, in order to effectively utilize available wind generation, it is usually given the highest priority by assigning zero or negative energy bidding prices when clearing the day-ahead electric power market. However, when congestion occurs, negative wind bidding prices would aggravate locational marginal prices (LMPs) to be negative in certain locations. A load shifting model is explored to alleviate possible congestions and enhance the utilization of wind generation, by shifting proper amount of load from peak hours to off peaks. The problem is to determine proper amount of load to be shifted, for enhancing the utilization of wind generation, alleviating transmission congestions, and making LMPs to be non-negative values. The second piece of work considered the price-based demand response (DR) program which is a mechanism for electricity consumers to dynamically manage their energy consumption in response to time-varying electricity prices. It encourages consumers to reduce their energy consumption when electricity prices are high, and thereby reduce the peak electricity demand and alleviate the pressure to power systems. However, it brings additional dynamics and new challenges on the real-time supply and demand balance. Specifically, price-sensitive DR load levels are constantly changing in response to dynamic real-time electricity prices, which will impact the economic dispatch (ED) schedule and in turn affect electricity market clearing prices. This thesis adopts two methods for examining the impacts of different DR price elasticity characteristics on the stability performance: a closed-loop iterative simulation method and a non-iterative method based on the contraction mapping theorem. This thesis also analyzes the financial stability of DR load consumers, by incorporating explicit LMP formulations and consumer payment requirements into the network-constrained unit commitment (NCUC) problem. The proposed model determines the proper amount of DR loads to be shifted from peak hours to off-peaks under ISO's direct load control, for reducing the operation cost and ensuring that consumer payments of DR loads will not deteriorate significantly after load shifting. Both MINLP and MILP models are discussed, and improved formulation strategies are presented.
A maintenance model for k-out-of-n subsystems aboard a fleet of advanced commercial aircraft
NASA Technical Reports Server (NTRS)
Miller, D. R.
1978-01-01
Proposed highly reliable fault-tolerant reconfigurable digital control systems for a future generation of commercial aircraft consist of several k-out-of-n subsystems. Each of these flight-critical subsystems will consist of n identical components, k of which must be functioning properly in order for the aircraft to be dispatched. Failed components are recoverable; they are repaired in a shop. Spares are inventoried at a main base where they may be substituted for failed components on planes during layovers. Penalties are assessed when failure of a k-out-of-n subsystem causes a dispatch cancellation or delay. A maintenance model for a fleet of aircraft with such control systems is presented. The goals are to demonstrate economic feasibility and to optimize.
Thermal Storage Applications Workshop. Volume 2: Contributed Papers
NASA Technical Reports Server (NTRS)
1979-01-01
The solar thermal and the thermal and thermochemical energy storage programs are described as well as the technology requirements for both external (electrical) and internal (thermal, chemical) modes for energy storage in solar power plants. Specific technical issues addressed include thermal storage criteria for solar power plants interfacing with utility systems; optimal dispatch of storage for solar plants in a conventional electric grid; thermal storage/temperature tradeoffs for solar total energy systems; the value of energy storage for direct-replacement solar thermal power plants; systems analysis of storage in specific solar thermal power applications; the value of seasonal storage of solar energy; criteria for selection of the thermal storage system for a 10 MW(2) solar power plant; and the need for specific requirements by storage system development teams.
GLIDES â Efficient Energy Storage from ORNL
Momen, Ayyoub M.; Abu-Heiba, Ahmad; Odukomaiya, Wale; Akinina, Alla
2018-06-25
The research shown in this video features the GLIDES (Ground-Level Integrated Diverse Energy Storage) project, which has been under development at Oak Ridge National Laboratory (ORNL) since 2013. GLIDES can store energy via combined inputs of electricity and heat, and deliver dispatchable electricity. Supported by ORNLâs Laboratory Directorâs Research and Development (LDRD) fund, this energy storage system is low-cost, and hybridizes compressed air and pumped-hydro approaches to allow for storage of intermittent renewable energy at high efficiency. A U.S. patent application for this novel energy storage concept has been submitted, and research findings suggest it has the potential to be a flexible, low-cost, scalable, high-efficiency option for energy storage, especially useful in residential and commercial buildings.
The Importance of Engine External's Health
NASA Technical Reports Server (NTRS)
Stoner, Barry L.
2006-01-01
Engine external components include all the fluid carrying, electron carrying, and support devices that are needed to operate the propulsion system. These components are varied and include: pumps, valves, actuators, solenoids, sensors, switches, heat exchangers, electrical generators, electrical harnesses, tubes, ducts, clamps and brackets. The failure of any component to perform its intended function will result in a maintenance action, a dispatch delay, or an engine in flight shutdown. The life of each component, in addition to its basic functional design, is closely tied to its thermal and dynamic environment .Therefore, to reach a mature design life, the component's thermal and dynamic environment must be understood and controlled, which can only be accomplished by attention to design analysis and testing. The purpose of this paper is to review analysis and test techniques toward achieving good component health.
GLIDES – Efficient Energy Storage from ORNL
DOE Office of Scientific and Technical Information (OSTI.GOV)
Momen, Ayyoub M.; Abu-Heiba, Ahmad; Odukomaiya, Wale
2016-03-01
The research shown in this video features the GLIDES (Ground-Level Integrated Diverse Energy Storage) project, which has been under development at Oak Ridge National Laboratory (ORNL) since 2013. GLIDES can store energy via combined inputs of electricity and heat, and deliver dispatchable electricity. Supported by ORNL’s Laboratory Director’s Research and Development (LDRD) fund, this energy storage system is low-cost, and hybridizes compressed air and pumped-hydro approaches to allow for storage of intermittent renewable energy at high efficiency. A U.S. patent application for this novel energy storage concept has been submitted, and research findings suggest it has the potential to bemore » a flexible, low-cost, scalable, high-efficiency option for energy storage, especially useful in residential and commercial buildings.« less
Developer view of the CSP evolution
NASA Astrophysics Data System (ADS)
Carvajal, Javier López; Barea, Jose M.; Barragan, Jose; Altmann, Thomas
2017-06-01
This paper briefly describes the history of CSP up to the present times and also gives some views about what could be expected in the near future for the industry. It also points out the relevance of the TES system as a key and gives some ideas regarding the innovations that could be expected in the coming CSP projects. Although currently, tower technology capacity under operation is less than 15% of the total CSP capacity in the world, solar tower, with molten salt most likely, might be the predominant technology in the medium run for electricity generation. In addition, other different concepts will be more commonly projected in order to increase dispatchability or renewable energy contribution in the electric system as hybridization with other technologies like PV or as part of desalination projects.
Stochastic Multi-Timescale Power System Operations With Variable Wind Generation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wu, Hongyu; Krad, Ibrahim; Florita, Anthony
This paper describes a novel set of stochastic unit commitment and economic dispatch models that consider stochastic loads and variable generation at multiple operational timescales. The stochastic model includes four distinct stages: stochastic day-ahead security-constrained unit commitment (SCUC), stochastic real-time SCUC, stochastic real-time security-constrained economic dispatch (SCED), and deterministic automatic generation control (AGC). These sub-models are integrated together such that they are continually updated with decisions passed from one to another. The progressive hedging algorithm (PHA) is applied to solve the stochastic models to maintain the computational tractability of the proposed models. Comparative case studies with deterministic approaches are conductedmore » in low wind and high wind penetration scenarios to highlight the advantages of the proposed methodology, one with perfect forecasts and the other with current state-of-the-art but imperfect deterministic forecasts. The effectiveness of the proposed method is evaluated with sensitivity tests using both economic and reliability metrics to provide a broader view of its impact.« less
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-24
... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-70-000] Texas Dispatchable Wind 1, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Texas Dispatchable Wind 1 LLC's application for market-based rate authority, with an accompanying rate...
14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...
14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...
14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...
14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...
14 CFR 121.601 - Aircraft dispatcher information to pilot in command: Domestic and flag operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... command: Domestic and flag operations. 121.601 Section 121.601 Aeronautics and Space FEDERAL AVIATION... Flight Release Rules § 121.601 Aircraft dispatcher information to pilot in command: Domestic and flag operations. (a) The aircraft dispatcher shall provide the pilot in command all available current reports or...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-28
... Courses AGENCY: Federal Aviation Administration (FAA), DOT. ACTION: Notice and request for comments... certification and approval of aircraft dispatcher courses. The FAA uses the information to ensure compliance and..., Subpart C, Aircraft Dispatchers and App. A Aircraft Dispatcher Courses. Form Numbers: There are no FAA...
VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITEWIDE ...
VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITE-WIDE FIRE ALARM SIGNALS, INCLUDING ALL FIRE PHONES, FIRE PULL BOXES, HEAT AND SMOKE DETECTORS, AND SUPPRESSION SYSTEM FLOW ALARMS, ARE TRANSMITTED TO THE BUILDING 331 DISPATCHER'S OFFICE. (3/77) - Rocky Flats Plant, Vehicle Maintenance Garage & Fire Station, Golden, Jefferson County, CO
NASA Technical Reports Server (NTRS)
Trujillo, Anna C.
1996-01-01
In 1993, fuel accounted for approximately 15 percent of an airline's expenses. Fuel consumption increases as fuel reserves increase because of the added weight to the aircraft. Calculating fuel reserves is a function of Federal Aviation Regulations, airline company policy, and factors that impact or are impacted by fuel usage enroute. This research studied how pilots and dispatchers determined the fuel needed for a flight and identified areas where improvements in methods may yield measurable fuel savings by (1) listing the uncertainties that contribute to adding contingency fuel, (2) obtaining the pilots' and dispatchers' perspective on how often each uncertainty occurred, and (3) obtaining pilots' and dispatchers' perspective on the fuel used for each occurrence. This study found that for the majority of the time, pilots felt that dispatchers included enough fuel. As for the uncertainties that flight crews and dispatchers account for, air traffic control accounts for 28% and weather uncertainties account for 58 percent. If improvements can be made in these two areas, a great potential exists to decrease the reserve required, and therefore, fuel usage without jeopardizing safety.
Multi-Temporal Decomposed Wind and Load Power Models for Electric Energy Systems
NASA Astrophysics Data System (ADS)
Abdel-Karim, Noha
This thesis is motivated by the recognition that sources of uncertainties in electric power systems are multifold and may have potentially far-reaching effects. In the past, only system load forecast was considered to be the main challenge. More recently, however, the uncertain price of electricity and hard-to-predict power produced by renewable resources, such as wind and solar, are making the operating and planning environment much more challenging. The near-real-time power imbalances are compensated by means of frequency regulation and generally require fast-responding costly resources. Because of this, a more accurate forecast and look-ahead scheduling would result in a reduced need for expensive power balancing. Similarly, long-term planning and seasonal maintenance need to take into account long-term demand forecast as well as how the short-term generation scheduling is done. The better the demand forecast, the more efficient planning will be as well. Moreover, computer algorithms for scheduling and planning are essential in helping the system operators decide what to schedule and planners what to build. This is needed given the overall complexity created by different abilities to adjust the power output of generation technologies, demand uncertainties and by the network delivery constraints. Given the growing presence of major uncertainties, it is likely that the main control applications will use more probabilistic approaches. Today's predominantly deterministic methods will be replaced by methods which account for key uncertainties as decisions are made. It is well-understood that although demand and wind power cannot be predicted at very high accuracy, taking into consideration predictions and scheduling in a look-ahead way over several time horizons generally results in more efficient and reliable utilization, than when decisions are made assuming deterministic, often worst-case scenarios. This change is in approach is going to ultimately require new electricity market rules capable of providing the right incentives to manage uncertainties and of differentiating various technologies according to the rate at which they can respond to ever changing conditions. Given the overall need for modeling uncertainties in electric energy systems, we consider in this thesis the problem of multi-temporal modeling of wind and demand power, in particular. Historic data is used to derive prediction models for several future time horizons. Short-term prediction models derived can be used for look-ahead economic dispatch and unit commitment, while the long-term annual predictive models can be used for investment planning. As expected, the accuracy of such predictive models depends on the time horizons over which the predictions are made, as well as on the nature of uncertain signals. It is shown that predictive models obtained using the same general modeling approaches result in different accuracy for wind than for demand power. In what follows, we introduce several models which have qualitatively different patterns, ranging from hourly to annual. We first transform historic time-stamped data into the Fourier Transform (Fr) representation. The frequency domain data representation is used to decompose the wind and load power signals and to derive predictive models relevant for short-term and long-term predictions using extracted spectral techniques. The short-term results are interpreted next as a Linear Prediction Coding Model (LPC) and its accuracy is analyzed. Next, a new Markov-Based Sensitivity Model (MBSM) for short term prediction has been proposed and the dispatched costs of uncertainties for different predictive models with comparisons have been developed. Moreover, the Discrete Markov Process (DMP) representation is applied to help assess probabilities of most likely short-, medium- and long-term states and the related multi-temporal risks. In addition, this thesis discusses operational impacts of wind power integration in different scenario levels by performing more than 9,000 AC Optimal Power Flow runs. The effects of both wind and load variations on system constraints and costs are presented. The limitations of DC Optimal Power Flow (DCOPF) vs. ACOPF are emphasized by means of system convergence problems due to the effect of wind power on changing line flows and net power injections. By studying the effect of having wind power on line flows, we found that the divergence problem applies in areas with high wind and hydro generation capacity share (cheap generations). (Abstract shortened by UMI.).
The welfare effects of integrating renewable energy into electricity markets
NASA Astrophysics Data System (ADS)
Lamadrid, Alberto J.
The challenges of deploying more renewable energy sources on an electric grid are caused largely by their inherent variability. In this context, energy storage can help make the electric delivery system more reliable by mitigating this variability. This thesis analyzes a series of models for procuring electricity and ancillary services for both individuals and social planners with high penetrations of stochastic wind energy. The results obtained for an individual decision maker using stochastic optimization are ambiguous, with closed form solutions dependent on technological parameters, and no consideration of the system reliability. The social planner models correctly reflect the effect of system reliability, and in the case of a Stochastic, Security Constrained Optimal Power Flow (S-SC-OPF or SuperOPF), determine reserve capacity endogenously so that system reliability is maintained. A single-period SuperOPF shows that including ramping costs in the objective function leads to more wind spilling and increased capacity requirements for reliability. However, this model does not reflect the inter temporal tradeoffs of using Energy Storage Systems (ESS) to improve reliability and mitigate wind variability. The results with the multiperiod SuperOPF determine the optimum use of storage for a typical day, and compare the effects of collocating ESS at wind sites with the same amount of storage (deferrable demand) located at demand centers. The collocated ESS has slightly lower operating costs and spills less wind generation compared to deferrable demand, but the total amount of conventional generating capacity needed for system adequacy is higher. In terms of the total system costs, that include the capital cost of conventional generating capacity, the costs with deferrable demand is substantially lower because the daily demand profile is flattened and less conventional generation capacity is then needed for reliability purposes. The analysis also demonstrates that the optimum daily pattern of dispatch and reserves is seriously distorted if the stochastic characteristics of wind generation are ignored.
Working Toward Policy-Relevant Air Quality Emissions Scenarios
NASA Astrophysics Data System (ADS)
Holloway, T.
2010-12-01
Though much work has been done to develop accurate chemical emission inventories, few publicly available inventories are appropriate for realistic policy analysis. Emissions from the electricity and transportation sectors, in particular, respond in complex ways to policy, technology, and energy use change. Many widely used inventories, such as the EPA National Emissions Inventory, are well-suited for modeling current air quality, but do not have the specificity needed to address "what if?" questions. Changes in electricity demand, fuel prices, new power sources, and emission controls all influence the emissions from regional power production, requiring a plant-by-plant assessment to capture the spatially explicit impacts. Similarly, land use, freight distribution, or driving behavior will yield differentiated transportation emissions for urban areas, suburbs, and rural highways. We here present results from three recent research projects at the University of Wisconsin—Madison, where bottom-up emission inventories for electricity, freight transport, and urban vehicle use were constructed to support policy-relevant air quality research. These three studies include: 1) Using the MyPower electricity dispatch model to calculate emissions and air quality impacts of Renewable Portfolio Standards and other carbon-management strategies; 2) Using advanced vehicle and commodity flow data from the Federal Highway Administration to evaluate the potential to shift commodities from truck to rail (assuming expanded infrastructure), and assess a range of alternative fuel suggestions; and 3) Working with urban planners to connect urban density with vehicle use to evaluate the air quality impacts of smart-growth in major Midwest cities. Drawing on the results of these three studies, and on challenges overcome in their execution, we discuss the current state of policy-relevant emission dataset generation, as well as techniques and attributes that need to be further refined in order to meet the increasingly intricate demands of both advanced air quality models and more realistic and relevant policy scenarios.
Registered nurses' experiences of their decision-making at an Emergency Medical Dispatch Centre.
Ek, Bosse; Svedlund, Marianne
2015-04-01
To describe registered nurses' experiences at an Emergency Medical Dispatch Centre. It is important that ambulances are urgently directed to patients who are in need of immediate help and of quick transportation to a hospital. Because resources are limited, Emergency Medical Dispatch centres cannot send ambulances with high priority to all callers. The efficiency of the system is therefore dependent on triage. Nurses worldwide are involved in patient triage, both before the patient's arrival to the hospital and in the subsequent emergency care. Ambulance dispatching is traditionally a duty for operators at Emergency Medical Dispatch centres, and in Sweden this duty has become increasingly performed by registered nurses. A qualitative design was used for this study. Fifteen registered nurses with experience at Emergency Medical Dispatch centres were interviewed. The participants were asked to describe the content of their work and their experiences. They also described the most challenging and difficult situations according to the critical incidence technique. Content analysis was used. Two themes emerged during the analysis: 'Having a profession with opportunities and obstacles' and 'Meeting serious and difficult situations', with eight sub-themes. The results showed that the decisions to dispatch ambulances were both challenging and difficult. Difficulties included conveying medical advice without seeing the patient, teaching cardio-pulmonary resuscitation via telephone and dealing with intoxicated and aggressive callers. Conflicts with colleagues and ambulance crews as well as fear of making wrong decisions were also mentioned. Work at Emergency Medical Dispatch centres is a demanding but stimulating duty for registered nurses. Great benefits can be achieved using experienced triage nurses, including increased patient safety and better use of medical resources. Improved internal support systems at Emergency Medical Dispatch centres and striving for a blame-free culture are important factors to attract and retain employees. © 2014 John Wiley & Sons Ltd.
Recommendations in dispatcher-assisted bystander resuscitation from emergency call center.
García del Águila, J; López-Messa, J; Rosell-Ortiz, F; de Elías Hernández, R; Martínez del Valle, M; Sánchez-Santos, L; López-Herce, J; Cerdà-Vila, M; Roza-Alonso, C L; Bernardez-Otero, M
2015-01-01
Dispatch-assisted bystander cardiopulmonary resuscitation in out-of-hospital cardiac arrest has been shown as an effective measure to improve the survival of this process. The development of a unified protocol for all dispatch centers of the different emergency medical services can be a first step towards this goal in our environment. The process of developing a recommendations document and the realization of posters of dispatch-assisted cardiopulmonary resuscitation, agreed by different actors and promoted by the Spanish Resuscitation Council, is presented. Copyright © 2015 Elsevier España, S.L.U. and SEMICYUC. All rights reserved.
Forecasting of Hourly Photovoltaic Energy in Canarian Electrical System
NASA Astrophysics Data System (ADS)
Henriquez, D.; Castaño, C.; Nebot, R.; Piernavieja, G.; Rodriguez, A.
2010-09-01
The Canarian Archipelago face similar problems as most insular region lacking of endogenous conventional energy resources and not connected to continental electrical grids. A consequence of the "insular fact" is the existence of isolated electrical systems that are very difficult to interconnect due to the considerable sea depths between the islands. Currently, the Canary Islands have six isolated electrical systems, only one utility generating most of the electricity (burning fuel), a recently arrived TSO (REE) and still a low implementation of Renewable Energy Resources (RES). The low level of RES deployment is a consequence of two main facts: the weakness of the stand-alone grids (from 12 MW in El Hierro up to only 1 GW in Gran Canaria) and the lack of space to install RES systems (more than 50% of the land protected due to environmental reasons). To increase the penetration of renewable energy generation, like solar or wind energy, is necessary to develop tools to manage them. The penetration of non manageable sources into weak grids like the Canarian ones causes a big problem to the grid operator. There are currently 104 MW of PV connected to the islands grids (Dec. 2009) and additional 150 MW under licensing. This power presents a serious challenge for the operation and stability of the electrical system. ITC, together with the local TSO (Red Eléctrica de España, REE) started in 2008 and R&D project to develop a PV energy prediction tool for the six Canarian Insular electrical systems. The objective is to supply reliable information for hourly forecast of the generation dispatch programme and to predict daily solar radiation patterns, in order to help program spinning reserves. ITC has approached the task of weather forecasting using different numerical model (MM5 and WRF) in combination with MSG (Meteosat Second Generation) images. From the online data recorded at several monitored PV plants and meteorological stations, PV nominal power and energy produced by every plant in Canary Islands are estimated using a series of theoretical and statistical energy models.
Barriers to dispatcher-assisted cardiopulmonary resuscitation in Singapore.
Ho, Andrew Fu Wah; Sim, Zariel Jiaying; Shahidah, Nur; Hao, Ying; Ng, Yih Yng; Leong, Benjamin S H; Zarinah, Siti; Teo, Winston K L; Goh, Geraldine Shu Yi; Jaafar, Hamizah; Ong, Marcus E H
2016-08-01
Dispatcher-assisted cardiopulmonary resuscitation (DA-CPR) is effective in increasing bystander CPR in out-of-hospital cardiac arrests (OHCA). Singapore has recently implemented a DA-CPR program. We aimed to characterize barriers to commencement of chest compressions by callers in Singapore. We analyzed dispatch recordings of OHCA cases received by the ambulance call center between July 2012 and March 2015. Audio recordings of poor quality were excluded. Trained reviewers noted the sequential stages of the dispatcher's recognition of CPR, delivering CPR instructions and caller performing CPR. Time taken to reach these milestones was noted. Barriers to chest compressions were identified. A total of 4897 OHCA occurred during the study period, overall bystander CPR rate was 45.7%. 1885 dispatch recordings were reviewed with 1157 cases qualified for dispatcher CPR. In 1128 (97.5%) cases, the dispatcher correctly recognized the need for CPR. CPR instructions were delivered in 1056 (91.3%) cases. Of these, 1007 (87.0%) callers performed CPR to instruction. One or more barriers to chest compressions were identified in 430 (37.2%) cases. The commonest barrier identified was "could not move patient" (27%). Cases where barriers were identified were less likely to have the need for CPR recognized by the dispatcher (94.9% vs. 99.0%, p<0.001), CPR instructions given (79.3% vs. 98.3%, p<0.001) and CPR started (67.9% vs. 98.3%, p<0.001), while the time taken to reach each of these stages were significantly longer (p<0.001). Barriers were present in 37% of cases. They were associated with lower proportion of CPR started and longer delay to CPR. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
A Hybrid Genetic Programming Algorithm for Automated Design of Dispatching Rules.
Nguyen, Su; Mei, Yi; Xue, Bing; Zhang, Mengjie
2018-06-04
Designing effective dispatching rules for production systems is a difficult and timeconsuming task if it is done manually. In the last decade, the growth of computing power, advanced machine learning, and optimisation techniques has made the automated design of dispatching rules possible and automatically discovered rules are competitive or outperform existing rules developed by researchers. Genetic programming is one of the most popular approaches to discovering dispatching rules in the literature, especially for complex production systems. However, the large heuristic search space may restrict genetic programming from finding near optimal dispatching rules. This paper develops a new hybrid genetic programming algorithm for dynamic job shop scheduling based on a new representation, a new local search heuristic, and efficient fitness evaluators. Experiments show that the new method is effective regarding the quality of evolved rules. Moreover, evolved rules are also significantly smaller and contain more relevant attributes.
NASA Astrophysics Data System (ADS)
Clack, C.; MacDonald, A. E.; Alexander, A.; Dunbar, A. D.; Xie, Y.; Wilczak, J. M.
2014-12-01
The importance of weather-driven renewable energies for the United States energy portfolio is growing. The main perceived problems with weather-driven renewable energies are their intermittent nature, low power density, and high costs. In 2009, we began a large-scale investigation into the characteristics of weather-driven renewables. The project utilized the best available weather data assimilation model to compute high spatial and temporal resolution power datasets for the renewable resources of wind and solar PV. The weather model used is the Rapid Update Cycle for the years of 2006-2008. The team also collated a detailed electrical load dataset for the contiguous USA from the Federal Energy Regulatory Commission for the same three-year period. The coincident time series of electrical load and weather data allows the possibility of temporally correlated computations for optimal design over large geographic areas. The past two years have seen the development of a cost optimization mathematic model that designs electric power systems. The model plans the system and dispatches it on an hourly timescale. The system is designed to be reliable, reduce carbon, reduce variability of renewable resources and move the electricity about the whole domain. The system built would create the infrastructure needed to reduce carbon emissions to 0 by 2050. The advantages of the system is reduced water demain, dual incomes for farmers, jobs for construction of the infrastructure, and price stability for energy. One important simplified test that was run included existing US carbon free power sources, natural gas power when needed, and a High Voltage Direct Current power transmission network. This study shows that the costs and carbon emissions from an optimally designed national system decrease with geographic size. It shows that with achievable estimates of wind and solar generation costs, that the US could decrease its carbon emissions by up to 80% by the early 2030s, without an increase in electric costs. The key requirement would be a 48 state network of HVDC transmission, creating a national market for electricity not possible in the current AC grid. The study also showed how the price of natural gas fuel influenced the optimal system designed.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hummon, M.; Jorgenson, J.; Denholm, P.
2013-10-01
Concentrating solar power with thermal energy storage (CSP-TES) can provide multiple benefits to the grid, including low marginal cost energy and the ability to levelize load, provide operating reserves, and provide firm capacity. It is challenging to properly value the integration of CSP because of the complicated nature of this technology. Unlike completely dispatchable fossil sources, CSP is a limited energy resource, depending on the hourly and daily supply of solar energy. To optimize the use of this limited energy, CSP-TES must be implemented in a production cost model with multiple decision variables for the operation of the CSP-TES plant.more » We develop and implement a CSP-TES plant in a production cost model that accurately characterizes the three main components of the plant: solar field, storage tank, and power block. We show the effect of various modelling simplifications on the value of CSP, including: scheduled versus optimized dispatch from the storage tank and energy-only operation versus co-optimization with ancillary services.« less
Modelling Concentrating Solar Power with Thermal Energy Storage for Integration Studies: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hummon, M.; Denholm, P.; Jorgenson, J.
2013-10-01
Concentrating solar power with thermal energy storage (CSP-TES) can provide multiple benefits to the grid, including low marginal cost energy and the ability to levelize load, provide operating reserves, and provide firm capacity. It is challenging to properly value the integration of CSP because of the complicated nature of this technology. Unlike completely dispatchable fossil sources, CSP is a limited energy resource, depending on the hourly and daily supply of solar energy. To optimize the use of this limited energy, CSP-TES must be implemented in a production cost model with multiple decision variables for the operation of the CSP-TES plant.more » We develop and implement a CSP-TES plant in a production cost model that accurately characterizes the three main components of the plant: solar field, storage tank, and power block. We show the effect of various modelling simplifications on the value of CSP, including: scheduled versus optimized dispatch from the storage tank and energy-only operation versus co-optimization with ancillary services.« less
Information processing in an urban fire department communication system.
Siegel, J; Weitzman, D O
1975-09-01
One of the most important functions of any fire department is to provide selective contact with fire fighting units and to dispatch these units based on information gathered from street alarm boxes and telephones. This paper is concerned with the problem of dispatching tactical response information to remote fire fighting units and with the effect of workload on the dispatch function.
NASA Astrophysics Data System (ADS)
Pan, Cong; Zhang, Jie; Qin, Wei
2017-05-01
As a key to improve the performance of the interbay automated material handling system (AMHS) in 300 mm semiconductor wafer fabrication system, the real-time overhead hoist transport (OHT) dispatching problem has received much attention. This problem is first formulated as a special form of assignment problem and it is proved that more than one solution will be obtained by Hungarian algorithm simultaneously. Through proposing and strictly proving two propositions related to the characteristics of these solutions, a modified Hungarian algorithm is designed to distinguish these solutions. Finally, a new real-time OHT dispatching method is carefully designed by implementing the solution obtained by the modified Hungarian algorithm. The experimental results of discrete event simulations show that, compared with conventional Hungarian algorithm dispatching method, the proposed dispatching method that chooses the solution with the maximum variance respectively reduces on average 4 s of the average waiting time and average lead time of wafer lots, and its performance is rather stable in multiple different scenarios of the interbay AMHS with different quantities of shortcuts. This research provides an efficient real-time OHT dispatching mechanism for the interbay AMHS with shortcuts and bypasses.
Neely, K W; Eldurkar, J A; Drake, M E
2000-02-01
Emergency medical services (EMS) systems increasingly seek to triage patients to alternative EMS resources. Emergency medical services dispatchers may be asked to perform this triage. New protocols may be necessary. Alternatively, existing protocols may be sufficient for this task. For an existing dispatch protocol to be sufficient, it at least must accurately categorize patient condition and severity based on an external standard. To examine the extent to which nature codes (NCs), or patient condition codes, and severity codes (SCs) currently assigned in one urban 911 center agree with paramedic field findings. The null hypothesis was that there is no routine agreement (75%) between dispatcher-assigned NC or SC and paramedic-assigned NC or SC for the same patient using the same protocol. Emergency medical services dispatch nature and severity code data and matching out-of-hospital data were prospectively gathered over six months. Dispatch data included the NC: caller-identified problem, and the SC: dispatcher-assessed severity. Each NC is modified by one of three SCs (1, 3, or 9): 1 is emergent, 3 is urgent, and 9 is neither. Paramedics verified and/or corrected dispatcher-assigned NCs and SCs using the same dispatch protocol. One thousand forty usable cases fell into 33 unique NC/SC combinations. The designation of SC 1 was assigned 275 times, SC 3 was assigned 736 times, and SC 9 was assigned 24 times. The SC was missing five times. The overall NC agreement was 0.70 (95% CI = 0.697 to 0.703). The overall SC agreement was 0.65 (95% CI = 0.645 to 0.655). The NC agreement exceeded 75% for ten (59%) NC/SC combinations. The SC agreement exceeded 75% for five (29%) NC/SC combinations. There was both NC and SC agreement for four (24%) combinations: urgent breathing problems, urgent diabetic problems, urgent falls, and urgent overdoses. The greatest NC/SC disagreement occurred within emergent and urgent traffic crashes. Paramedics adjusted SC toward lower severity 29% of the time and toward higher severity 5.4% of the time. There was no upward SC adjustment for eight (47%) combinations. Certain dispatcher-assigned NC and SC codes and NC/SC combinations achieved the study threshold. Overall agreement failed to achieve the threshold. The lowest SC level was rarely assigned, preventing a meaningful analysis of all severity levels.
Clawson, Jeff J; Gardett, Isabel; Scott, Greg; Fivaz, Conrad; Barron, Tracey; Broadbent, Meghan; Olola, Christopher
2018-02-01
Introduction Early recognition of an acute myocardial infarction (AMI) can increase the patient's likelihood of survival. As the first point of contact for patients accessing medical care through emergency services, emergency medical dispatchers (EMDs) represent the earliest potential identification point for AMIs. The objective of the study was to determine how AMI cases were coded and prioritized at the dispatch point, and also to describe the distribution of these cases by patient age and gender. Hypothesis/Problem No studies currently exist that describe the EMD's ability to correctly triage AMIs into Advanced Life Support (ALS) response tiers. The retrospective descriptive study utilized data from three sources: emergency medical dispatch, Emergency Medical Services (EMS), and emergency departments (EDs)/hospitals. The primary outcome measure was the distributions of AMI cases, as categorized by Chief Complaint Protocol, dispatch priority code and level, and patient age and gender. The EMS and ED/hospital data came from the Utah Department of Health (UDoH), Salt Lake City, Utah. Dispatch data came from two emergency communication centers covering the entirety of Salt Lake City and Salt Lake County, Utah. Overall, 89.9% of all the AMIs (n=606) were coded in one of the three highest dispatch priority levels, all of which call for ALS response (called CHARLIE, DELTA, and ECHO in the studied system). The percentage of AMIs significantly increased for patients aged 35 years and older, and varied significantly by gender, dispatch level, and chief complaint. A total of 85.7% of all deaths occurred among patients aged 55 years and older, and 88.9% of the deaths were handled in the ALS-recommended priority levels. Acute myocardial infarctions may present as a variety of clinical symptoms, and the study findings demonstrated that more than one-half were identified as having chief complaints of Chest Pain or Breathing Problems at the dispatch point, followed by Sick Person and Unconscious/Fainting. The 35-year age cutoff for assignment to higher priority levels is strongly supported. The Falls and Sick Person Protocols offer opportunities to capture atypical AMI presentations. Clawson JJ , Gardett I , Scott G , Fivaz C , Barron T , Broadbent M , Olola C . Hospital-confirmed acute myocardial infarction: prehospital identification using the Medical Priority Dispatch System. Prehosp Disaster Med. 2018;33(1):29-35.
Optimal Transmission Line Switching under Geomagnetic Disturbances
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Mowen; Nagarajan, Harsha; Yamangil, Emre
Recently, there have been increasing concerns about how geomagnetic disturbances (GMDs) impact electrical power systems. Geomagnetically-induced currents (GICs) can saturate transformers, induce hot spot heating and increase reactive power losses. These effects can potentially cause catastrophic damage to transformers and severely impact the ability of a power system to deliver power. To address this problem, we develop a model of GIC impacts to power systems that includes 1) GIC thermal capacity of transformers as a function of normal Alternating Current (AC) and 2) reactive power losses as a function of GIC. We also use this model to derive an optimizationmore » problem that protects power systems from GIC impacts through line switching, generator dispatch, and load shedding. We then employ state-of-the-art convex relaxations of AC power flow equations to lower bound the objective. We demonstrate the approach on a modified RTS96 system and UIUC 150-bus system and show that line switching is an effective means to mitigate GIC impacts. We also provide a sensitivity analysis of decisions with respect to GMD direction.« less
Optimal Transmission Line Switching under Geomagnetic Disturbances
Lu, Mowen; Nagarajan, Harsha; Yamangil, Emre; ...
2017-10-11
Recently, there have been increasing concerns about how geomagnetic disturbances (GMDs) impact electrical power systems. Geomagnetically-induced currents (GICs) can saturate transformers, induce hot spot heating and increase reactive power losses. These effects can potentially cause catastrophic damage to transformers and severely impact the ability of a power system to deliver power. To address this problem, we develop a model of GIC impacts to power systems that includes 1) GIC thermal capacity of transformers as a function of normal Alternating Current (AC) and 2) reactive power losses as a function of GIC. We also use this model to derive an optimizationmore » problem that protects power systems from GIC impacts through line switching, generator dispatch, and load shedding. We then employ state-of-the-art convex relaxations of AC power flow equations to lower bound the objective. We demonstrate the approach on a modified RTS96 system and UIUC 150-bus system and show that line switching is an effective means to mitigate GIC impacts. We also provide a sensitivity analysis of decisions with respect to GMD direction.« less
Spelten, Oliver; Warnecke, Tobias; Wetsch, Wolfgang A; Schier, Robert; Böttiger, Bernd W; Hinkelbein, Jochen
2016-08-01
High-quality cardiopulmonary resuscitation (CPR) by laypersons is a key determinant of both outcome and survival for out-of-hospital cardiac arrest. Dispatcher-assisted CPR (telephone-CPR, T-CPR) increases the frequency and correctness of bystander-CPR but results in prolonged time to first chest compressions. However, it remains unclear whether instructions for rescue ventilation and/or chest compressions should be recommended for dispatcher-assisted CPR. The aim of this study was to evaluate both principles of T-CPR with respect to CPR quality. Randomised controlled single-blinded manikin trial. University Hospital of Cologne, Germany, 1 July 2012 to 30 September 2012. Sixty laypersons between 18 and 65 years. Medically educated individuals, medical professionals and pregnant women were excluded. Participants were asked to resuscitate a manikin and were randomised into three groups: not dispatcher-assisted (uninstructed) CPR (group 1; U-CPR; n = 20), dispatcher-assisted compression-only CPR (group 2; DACO-CPR; n = 19) and full dispatcher-assisted CPR with rescue ventilation (group 3; DAF-CPR; n = 19). Specific parameters of CPR quality [i.e. no-flow-time (NFT) as well as compression and ventilation parameters] were analysed. To compare different groups we used Student's t test and P less than 0.05 was considered significant. Initial NFT was lowest in the DACO-CPR group (mean 21.3 ± 14.4%), followed by dispatcher-assisted full CPR (mean 49.1 ± 8.5%) and by unassisted CPR (mean 55.0 ± 12.9%). Initial NFT covering the time of instruction was lower in DACO-CPR (12.1 ± 5.4%) as compared to dispatcher-assisted full CPR (20.7 ± 8.1%). Compression depth was similar in all three groups: 40.6 ± 13.0 mm (unassisted CPR), 41.0 ± 12.2 mm (DACO-CPR) and 38.8 ± 15.8 mm (dispatcher-assisted full CPR). Average compression frequency was highest in the DACO-CPR group (65.2 ± 22.4 min) compared with the unassisted CPR group (35.6 ± 24.2 min) and the dispatcher-assisted full CPR group (44.5 ± 10.8 min). Correct rescue ventilation was given in 3.1 ± 11.1% (unassisted CPR) and 1.6 ± 16.1% (dispatcher-assisted full CPR) of all ventilation attempts. Best quality of CPR was achieved by DACO-CPR because of superior compression frequencies and reduced NFT. In contrast, the full dispatcher-assisted CPR with a longer initial instructing phase (initial NFT) did not result in enhanced CPR quality or an optimised compression depth.
Addressing forecast uncertainty impact on CSP annual performance
NASA Astrophysics Data System (ADS)
Ferretti, Fabio; Hogendijk, Christopher; Aga, Vipluv; Ehrsam, Andreas
2017-06-01
This work analyzes the impact of weather forecast uncertainty on the annual performance of a Concentrated Solar Power (CSP) plant. Forecast time series has been produced by a commercial forecast provider using the technique of hindcasting for the full year 2011 in hourly resolution for Ouarzazate, Morocco. Impact of forecast uncertainty has been measured on three case studies, representing typical tariff schemes observed in recent CSP projects plus a spot market price scenario. The analysis has been carried out using an annual performance model and a standard dispatch optimization algorithm based on dynamic programming. The dispatch optimizer has been demonstrated to be a key requisite to maximize the annual revenues depending on the price scenario, harvesting the maximum potential out of the CSP plant. Forecasting uncertainty affects the revenue enhancement outcome of a dispatch optimizer depending on the error level and the price function. Results show that forecasting accuracy of direct solar irradiance (DNI) is important to make best use of an optimized dispatch but also that a higher number of calculation updates can partially compensate this uncertainty. Improvement in revenues can be significant depending on the price profile and the optimal operation strategy. Pathways to achieve better performance are presented by having more updates both by repeatedly generating new optimized trajectories but also more often updating weather forecasts. This study shows the importance of working on DNI weather forecasting for revenue enhancement as well as selecting weather services that can provide multiple updates a day and probabilistic forecast information.
Reducing ambulance response times using discrete event simulation.
Wei Lam, Sean Shao; Zhang, Zhong Cheng; Oh, Hong Choon; Ng, Yih Ying; Wah, Win; Hock Ong, Marcus Eng
2014-01-01
The objectives of this study are to develop a discrete-event simulation (DES) model for the Singapore Emergency Medical Services (EMS), and to demonstrate the utility of this DES model for the evaluation of different policy alternatives to improve ambulance response times. A DES model was developed based on retrospective emergency call data over a continuous 6-month period in Singapore. The main outcome measure is the distribution of response times. The secondary outcome measure is ambulance utilization levels based on unit hour utilization (UHU) ratios. The DES model was used to evaluate different policy options in order to improve the response times, while maintaining reasonable fleet utilization. Three policy alternatives looking at the reallocation of ambulances, the addition of new ambulances, and alternative dispatch policies were evaluated. Modifications of dispatch policy combined with the reallocation of existing ambulances were able to achieve response time performance equivalent to that of adding 10 ambulances. The median (90th percentile) response time was 7.08 minutes (12.69 minutes). Overall, this combined strategy managed to narrow the gap between the ideal and existing response time distribution by 11-13%. Furthermore, the median UHU under this combined strategy was 0.324 with an interquartile range (IQR) of 0.047 versus a median utilization of 0.285 (IQR of 0.051) resulting from the introduction of additional ambulances. Response times were shown to be improved via a more effective reallocation of ambulances and dispatch policy. More importantly, the response time improvements were achieved without a reduction in the utilization levels and additional costs associated with the addition of ambulances. We demonstrated the effective use of DES as a versatile platform to model the dynamic system complexities of Singapore's national EMS systems for the evaluation of operational strategies to improve ambulance response times.
An Approximate Dynamic Programming Mode for Optimal MEDEVAC Dispatching
2015-03-26
over the myopic policy. This indicates the ADP policy is efficiently managing resources by 28 not immediately sending the nearest available MEDEVAC...DISPATCHING THESIS Presented to the Faculty Department of Operational Sciences Graduate School of Engineering and Management Air Force Institute of Technology...medical evacuation (MEDEVAC) dispatch policies. To solve the MDP, we apply an ap- proximate dynamic programming (ADP) technique. The problem of deciding
DOE Office of Scientific and Technical Information (OSTI.GOV)
Katz, Jessica; Denholm, Paul; Pless, Jacquelyn
Wind and solar are inherently more variable and uncertain than the traditional dispatchable thermal and hydro generators that have historically provided a majority of grid-supplied electricity. The unique characteristics of variable renewable energy (VRE) resources have resulted in many misperceptions regarding their contribution to a low-cost and reliable power grid. Common areas of concern include: 1) The potential need for increased operating reserves, 2) The impact of variability and uncertainty on operating costs and pollutant emissions of thermal plants, and 3) The technical limits of VRE penetration rates to maintain grid stability and reliability. This fact sheet corrects misperceptions inmore » these areas.« less
Smart Computer-Assisted Markets
NASA Astrophysics Data System (ADS)
McCabe, Kevin A.; Rassenti, Stephen J.; Smith, Vernon L.
1991-10-01
The deregulation movement has motivated the experimental study of auction markets designed for interdependent network industries such as natural gas pipelines or electric power systems. Decentralized agents submit bids to buy commodity and offers to sell transportation and commodity to a computerized dispatch center. Computer algorithms determine prices and allocations that maximize the gains from exchange in the system relative to the submitted bids and offers. The problem is important, because traditionally the scale and coordination economies in such industries were thought to require regulation. Laboratory experiments are used to study feasibility, limitations, incentives, and performance of proposed market designs for deregulation, providing motivation for new theory.
Dami, Fabrice; Fuchs, Vincent; Praz, Laurent; Vader, John-Paul
2010-07-01
In order to improve the quality of our Emergency Medical Services (EMS), to raise bystander cardiopulmonary resuscitation rates and thereby meet what is becoming a universal standard in terms of quality of emergency services, we decided to implement systematic dispatcher-assisted or telephone-CPR (T-CPR) in our medical dispatch center, a non-Advanced Medical Priority Dispatch System. The aim of this article is to describe the implementation process, costs and results following the introduction of this new "quality" procedure. This was a prospective study. Over an 8-week period, our EMS dispatchers were given new procedures to provide T-CPR. We then collected data on all non-traumatic cardiac arrests within our state (Vaud, Switzerland) for the following 12 months. For each event, the dispatchers had to record in writing the reason they either ruled out cardiac arrest (CA) or did not propose T-CPR in the event they did suspect CA. All emergency call recordings were reviewed by the medical director of the EMS. The analysis of the recordings and the dispatchers' written explanations were then compared. During the 12-month study period, a total of 497 patients (both adults and children) were identified as having a non-traumatic cardiac arrest. Out of this total, 203 cases were excluded and 294 cases were eligible for T-CPR. Out of these eligible cases, dispatchers proposed T-CPR on 202 occasions (or 69% of eligible cases). They also erroneously proposed T-CPR on 17 occasions when a CA was wrongly identified (false positive). This represents 7.8% of all T-CPR. No costs were incurred to implement our study protocol and procedures. This study demonstrates it is possible, using a brief campaign of sensitization but without any specific training, to implement systematic dispatcher-assisted cardiopulmonary resuscitation in a non-Advanced Medical Priority Dispatch System such as our EMS that had no prior experience with systematic T-CPR. The results in terms of T-CPR delivery rate and false positive are similar to those found in previous studies. We found our results satisfying the given short time frame of this study. Our results demonstrate that it is possible to improve the quality of emergency services at moderate or even no additional costs and this should be of interest to all EMS that do not presently benefit from using T-CPR procedures. EMS that currently do not offer T-CPR should consider implementing this technique as soon as possible, and we expect our experience may provide answers to those planning to incorporate T-CPR in their daily practice.
A Decomposition Method for Security Constrained Economic Dispatch of a Three-Layer Power System
NASA Astrophysics Data System (ADS)
Yang, Junfeng; Luo, Zhiqiang; Dong, Cheng; Lai, Xiaowen; Wang, Yang
2018-01-01
This paper proposes a new decomposition method for the security-constrained economic dispatch in a three-layer large-scale power system. The decomposition is realized using two main techniques. The first is to use Ward equivalencing-based network reduction to reduce the number of variables and constraints in the high-layer model without sacrificing accuracy. The second is to develop a price response function to exchange signal information between neighboring layers, which significantly improves the information exchange efficiency of each iteration and results in less iterations and less computational time. The case studies based on the duplicated RTS-79 system demonstrate the effectiveness and robustness of the proposed method.
Energy Systems Analysis Tools | Energy Analysis | NREL
energy resources. REFlex NREL uses this dispatch model to evaluate renewable generation as a function of information. Regional Energy Deployment System (ReEDS) NREL uses this multi-regional, multi-time period, GIS
Green Power Grids: How Energy from Renewable Sources Affects Networks and Markets
Mureddu, Mario; Caldarelli, Guido; Chessa, Alessandro; Scala, Antonio; Damiano, Alfonso
2015-01-01
The increasing attention to environmental issues is forcing the implementation of novel energy models based on renewable sources. This is fundamentally changing the configuration of energy management and is introducing new problems that are only partly understood. In particular, renewable energies introduce fluctuations which cause an increased request for conventional energy sources to balance energy requests at short notice. In order to develop an effective usage of low-carbon sources, such fluctuations must be understood and tamed. In this paper we present a microscopic model for the description and for the forecast of short time fluctuations related to renewable sources in order to estimate their effects on the electricity market. To account for the inter-dependencies in the energy market and the physical power dispatch network, we use a statistical mechanics approach to sample stochastic perturbations in the power system and an agent based approach for the prediction of the market players’ behavior. Our model is data-driven; it builds on one-day-ahead real market transactions in order to train agents’ behaviour and allows us to deduce the market share of different energy sources. We benchmarked our approach on the Italian market, finding a good accordance with real data. PMID:26335705
Green Power Grids: How Energy from Renewable Sources Affects Networks and Markets.
Mureddu, Mario; Caldarelli, Guido; Chessa, Alessandro; Scala, Antonio; Damiano, Alfonso
2015-01-01
The increasing attention to environmental issues is forcing the implementation of novel energy models based on renewable sources. This is fundamentally changing the configuration of energy management and is introducing new problems that are only partly understood. In particular, renewable energies introduce fluctuations which cause an increased request for conventional energy sources to balance energy requests at short notice. In order to develop an effective usage of low-carbon sources, such fluctuations must be understood and tamed. In this paper we present a microscopic model for the description and for the forecast of short time fluctuations related to renewable sources in order to estimate their effects on the electricity market. To account for the inter-dependencies in the energy market and the physical power dispatch network, we use a statistical mechanics approach to sample stochastic perturbations in the power system and an agent based approach for the prediction of the market players' behavior. Our model is data-driven; it builds on one-day-ahead real market transactions in order to train agents' behaviour and allows us to deduce the market share of different energy sources. We benchmarked our approach on the Italian market, finding a good accordance with real data.
Improving emergency medical dispatching with emphasis on mass-casualty incidents.
Kleinoscheg, Gabriel; Burgsteiner, Harald; Bernroider, Martin; Kiechle, Günter; Obermayer, Maria
2014-01-01
Dispatching ambulances is a demanding and stressful task for dispatchers. This is especially true in case of mass-casualty incidents. Therefore, the aim of this work was to investigate if and to what extent the dispatch operation of the Red Cross Salzburg can be optimized on such occasions with a computerized system. The basic problem of a dynamic multi-vehicle Dial-a-Ride Problem with time windows was enhanced according to the requirements of the Red Cross Salzburg. The general objective was to minimize the total mileage covered by ambulances and the waiting time of patients. Furthermore, in case of emergencies suitable adaptions to a plan should be carried out automatically. Consequently, the problem is solved by using the Adaptive Large Neighborhood Search. Evaluation results indicate that the system outperforms a human dispatcher by between 2.5% and 36% within 1 minute of runtime concerning total costs. Moreover, the system's response time in case that a plan has to be updated is less than 1 minute on average.
ERIC Educational Resources Information Center
Osman, Abdulaziz
2016-01-01
The purpose of this research study was to examine the unknown fears of embracing cloud computing which stretches across measurements like fear of change from leaders and the complexity of the technology in 9-1-1 dispatch centers in USA. The problem that was addressed in the study was that many 9-1-1 dispatch centers in USA are still using old…
Newton, P R; Naidoo, R; Brysiewicz, P
2015-09-19
Emergency medical services (EMS) are sometimes required to respond to cases that are later found not to be emergencies, resulting in high levels of inappropriate responses. This study evaluated the extent to which this occurs. All cases dispatched over 72 hours by the eThekwini EMS in Durban, South Africa, were prospectively enrolled in a quantitative descriptive study. Vehicle control forms containing dispatch data were matched and compared with patient report forms containing epidemiological and clinical data to describe the nature and extent of inappropriate responses based on patient need. Data were subjected to simple descriptive analysis, correlations and χ2 testing. A total of 1 385 cases met the study inclusion criteria. Marked variations existed between dispatch and on-scene priority settings, most notably in the highest priority 'red-code' category, which constituted >56% of cases dispatched yet accounted for <2% at the scene (p<0.001). Conversely, >80% of 'red-code' dispatches required a lower priority response. When comparing resource allocation according to patient interventional needs, >58% of cases required either no intervention or transport only and almost 36% required basic life support intervention only (p<0.001). Moreover, <12% of advanced life support dispatches were for patients found to be 'red code' at the scene. There is a significant mismatch between the dispatch of EMS resources and actual patient need in the eThekwini district, with significantly high levels of inappropriate emergency responses.
Andersen, Kasper; Mikkelsen, Søren; Jørgensen, Gitte; Zwisler, Stine Thorhauge
2018-01-05
Little is known regarding paediatric medical emergency calls to Danish Emergency Medical Dispatch Centres (EMDC). This study aimed to investigate these calls, specifically the medical issues leading to them and the pre-hospital units dispatched to the paediatric emergencies. We performed a retrospective, observational study on paediatric medical emergency calls managed by the EMDC in the Region of Southern Denmark in February 2016. We reviewed audio recordings of emergency calls and ambulance records to identify calls concerning patients ≤ 15 years. We examined EMDC dispatch records to establish how the medical issues leading to these calls were classified and which pre-hospital units were dispatched to the paediatric emergencies. We analysed the data using descriptive statistics. Of a total of 7052 emergency calls in February 2016, 485 (6.9%) concerned patients ≤ 15 years. We excluded 19 and analysed the remaining 466. The reported medical issues were commonly classified as: "seizures" (22.1%), "sick child" (18.9%) and "unclear problem" (12.9%). The overall most common pre-hospital response was immediate dispatch of an ambulance with sirens and lights with a supporting physician-manned mobile emergency care unit (56.4%). The classification of medical issues and the dispatched pre-hospital units varied with patient age. We believe our results might help focus the paediatric training received by emergency medical dispatch staff on commonly encountered medical issues, such as the symptoms and conditions pertaining to the symptom categories "seizures" and "sick child". Furthermore, the results could prove useful in hypothesis generation for future studies examining paediatric medical emergency calls. Almost 7% of all calls concerned patients ≤ 15 years. Medical issues pertaining to the symptom categories "seizures", "sick child" and "unclear problem" were common and the calls commonly resulted in urgent pre-hospital responses.
Stress and salivary cortisol in emergency medical dispatchers: A randomized shifts control trial
Bedini, Sarah; Braun, François; Weibel, Laurence; Aussedat, Michel; Pereira, Bruno; Dutheil, Frédéric
2017-01-01
Stress at work is a public health concern. Phone operators in emergency medical dispatch centers are particularly at risk. We aimed to demonstrate that the most stressful time for emergency medical dispatchers is the shift when they receive emergency incoming calls, with cortisol as a biomarker of stress. For each emergency medical dispatcher, we measured outcomes over a control day and during three types of shift: Incoming emergency call, Dispatch and Re-assessment. The pattern of shifts was randomized. Saliva was sampled every 15 minutes for 2 hours, i.e. 6 consecutive times, starting 15 minutes after the first life-and-death incoming emergency call between 2 and 5 pm during three types of shift. We measured saliva cortisol every 2 hours over a control day, from 7am to 9pm. Perceived stress was assessed by a visual analog scale. We recruited 22 phone operators aged 36.4+/-10.8 years old (14 women and 8 men). Cortisol values were higher during the Incoming emergency call shift than during the Dispatch (p = .04) and Re-assessment (p = .04) shifts. The increase in cortisol levels was greater in men than in women (p = .009). There were no differences between control values and those of the three shifts. The kinetics of cortisol increased with greater perceived stress overall (p < .001) and for each type of shift (Incoming emergency call, p = .02; Dispatch p = .03; Re-assessment: p < .001). The kinetics of cortisol in response to incoming emergency calls was greater when the call was an absolute emergency (p = .03), and also tended to further increase when a subsequent absolute incoming emergency call was received (p = 0.07). In conclusion, the incoming emergency call shift carries particular risk for dispatchers, who have greater perceived stress and a greater increase in cortisol levels. PMID:28505199
Stress and salivary cortisol in emergency medical dispatchers: A randomized shifts control trial.
Bedini, Sarah; Braun, François; Weibel, Laurence; Aussedat, Michel; Pereira, Bruno; Dutheil, Frédéric
2017-01-01
Stress at work is a public health concern. Phone operators in emergency medical dispatch centers are particularly at risk. We aimed to demonstrate that the most stressful time for emergency medical dispatchers is the shift when they receive emergency incoming calls, with cortisol as a biomarker of stress. For each emergency medical dispatcher, we measured outcomes over a control day and during three types of shift: Incoming emergency call, Dispatch and Re-assessment. The pattern of shifts was randomized. Saliva was sampled every 15 minutes for 2 hours, i.e. 6 consecutive times, starting 15 minutes after the first life-and-death incoming emergency call between 2 and 5 pm during three types of shift. We measured saliva cortisol every 2 hours over a control day, from 7am to 9pm. Perceived stress was assessed by a visual analog scale. We recruited 22 phone operators aged 36.4+/-10.8 years old (14 women and 8 men). Cortisol values were higher during the Incoming emergency call shift than during the Dispatch (p = .04) and Re-assessment (p = .04) shifts. The increase in cortisol levels was greater in men than in women (p = .009). There were no differences between control values and those of the three shifts. The kinetics of cortisol increased with greater perceived stress overall (p < .001) and for each type of shift (Incoming emergency call, p = .02; Dispatch p = .03; Re-assessment: p < .001). The kinetics of cortisol in response to incoming emergency calls was greater when the call was an absolute emergency (p = .03), and also tended to further increase when a subsequent absolute incoming emergency call was received (p = 0.07). In conclusion, the incoming emergency call shift carries particular risk for dispatchers, who have greater perceived stress and a greater increase in cortisol levels.
Due Date Assignment in a Dynamic Job Shop with the Orthogonal Kernel Least Squares Algorithm
NASA Astrophysics Data System (ADS)
Yang, D. H.; Hu, L.; Qian, Y.
2017-06-01
Meeting due dates is a key goal in the manufacturing industries. This paper proposes a method for due date assignment (DDA) by using the Orthogonal Kernel Least Squares Algorithm (OKLSA). A simulation model is built to imitate the production process of a highly dynamic job shop. Several factors describing job characteristics and system state are extracted as attributes to predict job flow-times. A number of experiments under conditions of varying dispatching rules and 90% shop utilization level have been carried out to evaluate the effectiveness of OKLSA applied for DDA. The prediction performance of OKLSA is compared with those of five conventional DDA models and back-propagation neural network (BPNN). The experimental results indicate that OKLSA is statistically superior to other DDA models in terms of mean absolute lateness and root mean squares lateness in most cases. The only exception occurs when the shortest processing time rule is used for dispatching jobs, the difference between OKLSA and BPNN is not statistically significant.
NASA Astrophysics Data System (ADS)
Kim, Byung Soo; Lee, Woon-Seek; Koh, Shiegheun
2012-07-01
This article considers an inbound ordering and outbound dispatching problem for a single product in a third-party warehouse, where the demands are dynamic over a discrete and finite time horizon, and moreover, each demand has a time window in which it must be satisfied. Replenishing orders are shipped in containers and the freight cost is proportional to the number of containers used. The problem is classified into two cases, i.e. non-split demand case and split demand case, and a mathematical model for each case is presented. An in-depth analysis of the models shows that they are very complicated and difficult to find optimal solutions as the problem size becomes large. Therefore, genetic algorithm (GA) based heuristic approaches are designed to solve the problems in a reasonable time. To validate and evaluate the algorithms, finally, some computational experiments are conducted.
Model Predictive Control-based Optimal Coordination of Distributed Energy Resources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayhorn, Ebony T.; Kalsi, Karanjit; Lian, Jianming
2013-01-07
Distributed energy resources, such as renewable energy resources (wind, solar), energy storage and demand response, can be used to complement conventional generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging, especially in isolated systems. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation performance. The goals of the optimization problem are to minimize fuel costs and maximize the utilization of wind while considering equipment life of generators and energy storage. Model predictive controlmore » (MPC) is used to solve a look-ahead dispatch optimization problem and the performance is compared to an open loop look-ahead dispatch problem. Simulation studies are performed to demonstrate the efficacy of the closed loop MPC in compensating for uncertainties and variability caused in the system.« less
Model Predictive Control-based Optimal Coordination of Distributed Energy Resources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mayhorn, Ebony T.; Kalsi, Karanjit; Lian, Jianming
2013-04-03
Distributed energy resources, such as renewable energy resources (wind, solar), energy storage and demand response, can be used to complement conventional generators. The uncertainty and variability due to high penetration of wind makes reliable system operations and controls challenging, especially in isolated systems. In this paper, an optimal control strategy is proposed to coordinate energy storage and diesel generators to maximize wind penetration while maintaining system economics and normal operation performance. The goals of the optimization problem are to minimize fuel costs and maximize the utilization of wind while considering equipment life of generators and energy storage. Model predictive controlmore » (MPC) is used to solve a look-ahead dispatch optimization problem and the performance is compared to an open loop look-ahead dispatch problem. Simulation studies are performed to demonstrate the efficacy of the closed loop MPC in compensating for uncertainties and variability caused in the system.« less
Capacity Adequacy and Revenue Sufficiency in Electricity Markets With Wind Power
DOE Office of Scientific and Technical Information (OSTI.GOV)
Levin, Todd; Botterud, Audun
2015-05-01
We present a computationally efficient mixed-integer program (MIP) that determines optimal generator expansion decisions, as well as periodic unit commitment and dispatch. The model is applied to analyze the impact of increasing wind power capacity on the optimal generation mix and the profitability of thermal generators. In a case study, we find that increasing wind penetration reduces energy prices while the prices for operating reserves increase. Moreover, scarcity pricing for operating reserves through reserve shortfall penalties significantly impacts the prices and profitability of thermal generators. Without scarcity pricing, no thermal units are profitable, however scarcity pricing can ensure profitability formore » peaking units at high wind penetration levels. Capacity payments can also ensure profitability, but the payments required for baseload units to break even increase with the amount of wind power. The results indicate that baseload units are most likely to experience revenue sufficiency problems when wind penetration increases and new baseload units are only developed when natural gas prices are high and wind penetration is low.« less
Real-Time, Wide Area Dispatch of Mobil Tank Trucks
1987-01-01
human dispatchers it assists. Using CAD, Mobil has substantially re- duced costs and staff while improving customer service. I n the spring of 1985, a...process by establishing the Mobil order response center (MORC). To use MORC, the customer dials a toll-free number, available 24 hours a day, seven...MATS Figwe 3: Mobil light products order and dispatch information flow. Customers call an audio re- sponse computer system named MORC ( Mobil order
Buscheck, Thomas A.; Bielicki, Jeffrey M.; Edmunds, Thomas A.; ...
2016-05-05
We present an approach that uses the huge fluid and thermal storage capacity of the subsurface, together with geologic carbon dioxide (CO 2) storage, to harvest, store, and dispatch energy from subsurface (geothermal) and surface (solar, nuclear, fossil) thermal resources, as well as excess energy on electric grids. Captured CO 2 is injected into saline aquifers to store pressure, generate artesian flow of brine, and provide a supplemental working fluid for efficient heat extraction and power conversion. Concentric rings of injection and production wells create a hydraulic mound to store pressure, CO 2, and thermal energy. This energy storage canmore » take excess power from the grid and excess/waste thermal energy, and dispatch that energy when it is demanded and thus enable higher penetration of variable renewable energy technologies (e.g., wind, solar). CO 2 stored in the subsurface functions as a cushion gas to provide enormous pressure-storage capacity and displace large quantities of brine, some of which can be treated for a variety of beneficial uses. Geothermal power and energy-storage applications may generate enough revenues to compensate for CO 2 capture costs. While our approach can use nitrogen (N 2), in addition to CO 2, as a supplemental fluid, and store thermal energy, this study focuses using CO 2 for geothermal energy production and grid-scale energy storage. We conduct a techno-economic assessment to determine the levelized cost of electricity of using this approach to generate geothermal power. We present a reservoir pressure-management strategy that diverts a small portion of the produced brine for beneficial consumptive use to reduce the pumping cost of fluid recirculation, while reducing the risk of seismicity, caprock fracture, and CO 2 leakage.« less
Electricity market pricing, risk hedging and modeling
NASA Astrophysics Data System (ADS)
Cheng, Xu
In this dissertation, we investigate the pricing, price risk hedging/arbitrage, and simplified system modeling for a centralized LMP-based electricity market. In an LMP-based market model, the full AC power flow model and the DC power flow model are most widely used to represent the transmission system. We investigate the differences of dispatching results, congestion pattern, and LMPs for the two power flow models. An appropriate LMP decomposition scheme to quantify the marginal costs of the congestion and real power losses is critical for the implementation of financial risk hedging markets. However, the traditional LMP decomposition heavily depends on the slack bus selection. In this dissertation we propose a slack-independent scheme to break LMP down into energy, congestion, and marginal loss components by analyzing the actual marginal cost of each bus at the optimal solution point. The physical and economic meanings of the marginal effect at each bus provide accurate price information for both congestion and losses, and thus the slack-dependency of the traditional scheme is eliminated. With electricity priced at the margin instead of the average value, the market operator typically collects more revenue from power sellers than that paid to power buyers. According to the LMP decomposition results, the revenue surplus is then divided into two parts: congestion charge surplus and marginal loss revenue surplus. We apply the LMP decomposition results to the financial tools, such as financial transmission right (FTR) and loss hedging right (LHR), which have been introduced to hedge against price risks associated to congestion and losses, to construct a full price risk hedging portfolio. The two-settlement market structure and the introduction of financial tools inevitably create market manipulation opportunities. We investigate several possible market manipulation behaviors by virtual bidding and propose a market monitor approach to identify and quantify such behavior. Finally, the complexity of the power market and size of the transmission grid make it difficult for market participants to efficiently analyze the long-term market behavior. We propose a simplified power system commercial model by simulating the PTDFs of critical transmission bottlenecks of the original system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
McMillan, Colin; Boardman, Richard; McKellar, Michael
Changes are occurring throughout the U.S. economy, especially in regard to how energy is generated and used in the electricity, buildings, industrial, and transportation sectors. These changes are being driven by environmental and energy security concerns and by economics. The electric-sector market share of natural gas and variable renewable generation, such as wind and solar photovoltaics (PV), continues to grow. The buildings sector is evolving to meet efficiency standards, the transportation sector is evolving to meet efficiency and renewable fuels standards, and the industrial sector is evolving to reduce emissions. Those changes are driving investment and utilization strategies for generationmore » and other assets. Nuclear and renewable energy sources are important to consider in the energy sector’s evolution because both are considered to be clean and non-carbon-emitting energy sources. The Idaho National Laboratory (INL) and the National Renewable Energy Laboratory (NREL) are jointly investigating potential synergies between technologies exploiting nuclear and renewable energy sources. The two laboratories have held several joint workshops since 2011. Those workshops brought together experts in both areas to identify synergies and potential opportunities to work together. Workshop participants identified nuclear-renewable hybrid energy systems (N-R HESs) as one of the opportunities and recommended investigating whether N-R HESs could both generate dispatchable electricity without carbon emissions and provide clean energy to industrial processes. They also recommended analyzing the potential for N-R HESs to provide dispatchable capacity to a grid with high penetrations of non-dispatchable resources and to investigate whether real inertia provided by thermal power cycles within N-R HESs provides value to the grid. This report is one of a series of reports INL and NREL are producing to investigate the technical and economic aspects of N-R HESs. Previous reports focused on tightly coupled N-R HESs. Previously, INL analyzed the dynamic performance of two hypothetical N-R HESs and NREL analyzed the optimal economic configurations and operation of the same two N-R HESs. The first of those two is a Texas-synthetic gasoline scenario that includes four subsystems: a nuclear reactor, thermal power cycle, wind power plant, and synthetic gasoline production technology. The second hypothetical N-R HES is an Arizona-desalination scenario with four subsystems: a nuclear reactor, thermal power cycle, PV, and a desalination plant. INL analyzed the technical performance of the same two N-R HESs in another report. In another report NREL used the Texas-synthetic gasoline scenario provides the basis; however, the industrial process was removed. Instead, that N-R HES sells heat directly to an industrial customer. Subsystems that convert electricity to heat were also included. Future analyses are planned for other N-R HES options including one where hydrogen is produced within an N-R HES. This report quantifies greenhouse gas (GHG) emissions from the industrial sector and identifies opportunities for non-GHG-emitting thermal energy sources, such as N-R HESs, to replace the most significant GHG-emitting U.S. industries based on targeted, process-level analysis of industrial heat requirements.« less
Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey
2018-01-01
To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio ( n =57); or (2) verbal dispatcher assistance ( n =52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P >0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P <0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min -1 ) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.
Clawson, Jeff J; Scott, Greg; Gardett, Isabel; Youngquist, Scott; Taillac, Peter; Fivaz, Conrad; Olola, Christopher
2016-08-01
Early hospital notification of a possible stroke arriving via emergency medical services (EMS) can prepare stroke center personnel for timely treatment, especially timely administration of tissue plasminogen activator. Stroke center notification from the emergency dispatch center-before responders reach the scene-may promote even earlier and faster system activation, meaning that stroke center teams may be ready to receive patients as soon as the ambulance arrives. This study evaluates the use of a Medical Priority Dispatch System (MPDS; Priority Dispatch Corp., Salt Lake City, UT) Stroke Diagnostic Tool (SDxT) to identify possible strokes early by comparing the tools' results to on-scene and hospital findings. The retrospective descriptive study utilized stroke data from 3 sources: emergency medical dispatch, EMS, and emergency department/hospital. A total of 830 cases were collected between June 2012 and December 2013, of which 603 (72.7%) had matching dispatch records. Of the 603 cases, 304 (50.4%) were handled using MPDS Stroke Protocol 28. The SDxT had an 86.4% ability (OR [95% CI]: 2.3 [1.5, 3.5]) to effectively identify strokes among all the hospital-confirmed stroke cases (sensitivity), and a 26.6% ability to effectively identify nonstrokes among all the hospital-confirmed nonstroke cases (specificity). The SDxT demonstrated a very high sensitivity, compared to similar tools used in the field and at dispatch. The specificity was somewhat low, but this was expected-and is intended in the creation of protocols to be used over the phone in emergency situations. The tool is a valuable method for identifying strokes early and may allow early hospital notification. Copyright © 2016 National Stroke Association. Published by Elsevier Inc. All rights reserved.
Rasmussen, Stinne Eika; Nebsbjerg, Mette Amalie; Krogh, Lise Qvirin; Bjørnshave, Katrine; Krogh, Kristian; Povlsen, Jonas Agerlund; Riddervold, Ingunn Skogstad; Grøfte, Thorbjørn; Kirkegaard, Hans; Løfgren, Bo
2017-01-01
Emergency dispatchers use protocols to instruct bystanders in cardiopulmonary resuscitation (CPR). Studies changing one element in the dispatcher's protocol report improved CPR quality. Whether several changes interact is unknown and the effect of combining multiple changes previously reported to improve CPR quality into one protocol remains to be investigated. We hypothesize that a novel dispatch protocol, combining multiple beneficial elements improves CPR quality compared with a standard protocol. A novel dispatch protocol was designed including wording on chest compressions, using a metronome, regular encouragements and a 10-s rest each minute. In a simulated cardiac arrest scenario, laypersons were randomized to perform single-rescuer CPR guided with the novel or the standard protocol. a composite endpoint of time to first compression, hand position, compression depth and rate and hands-off time (maximum score: 22 points). Afterwards participants answered a questionnaire evaluating the dispatcher assistance. The novel protocol (n=61) improved CPR quality score compared with the standard protocol (n=64) (mean (SD): 18.6 (1.4)) points vs. 17.5 (1.7) points, p<0.001. The novel protocol resulted in deeper chest compressions (mean (SD): 58 (12)mm vs. 52 (13)mm, p=0.02) and improved rate of correct hand position (61% vs. 36%, p=0.01) compared with the standard protocol. In both protocols hands-off time was short. The novel protocol improved motivation among rescuers compared with the standard protocol (p=0.002). Participants guided with a standard dispatch protocol performed high quality CPR. A novel bundle of care protocol improved CPR quality score and motivation among rescuers. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
Interior view of Dispatch Office and counter, facing south ...
Interior view of Dispatch Office and counter, facing south - International Longshoremen's & Warehousemen's Union Hall, Naval Civil Engineering Laboratory, Port Hueneme Road, Port Hueneme, Ventura County, CA
Wang, Hao; Zhang, Kai; Chen, Junhua; Wang, Zhifeng; Li, Guijun; Yang, Yuqi
2018-05-01
Taxis are an important component of urban passenger transport. Research on the daily dispatching of taxis and the utility of governmental management is important for the improvement of passenger travel, taxi driver income and environmental impacts. However, urban taxi management is a complex and dynamic system that is affected by many factors, and positive/negative feedback relationships and nonlinear interactions exist between each subsystem and variable. Therefore, conventional research methods can hardly depict its characteristics comprehensively. To bridge this gap, this paper develops a system dynamics model of urban taxi management, in which the empty-loaded rate and total demand are selected as key factors affecting taxi dispatching, and the impacts of taxi fares on driver income and travel demand are taken into account. After the validation of the model, taxi operations data derived from a prior analysis of origin-destination data of Beijing taxis are used as input for the model to simulate the taxi market in Beijing. Finally, economic and environmental implications are provided for the government to optimise policies on taxi management. Copyright © 2018 Elsevier Ltd. All rights reserved.
Impact of Uncertainty from Load-Based Reserves and Renewables on Dispatch Costs and Emissions
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Bowen; Maroukis, Spencer D.; Lin, Yashen
2016-11-21
Aggregations of controllable loads are considered to be a fast-responding, cost-efficient, and environmental-friendly candidate for power system ancillary services. Unlike conventional service providers, the potential capacity from the aggregation is highly affected by factors like ambient conditions and load usage patterns. Previous work modeled aggregations of controllable loads (such as air conditioners) as thermal batteries, which are capable of providing reserves but with uncertain capacity. A stochastic optimal power flow problem was formulated to manage this uncertainty, as well as uncertainty in renewable generation. In this paper, we explore how the types and levels of uncertainty, generation reserve costs, andmore » controllable load capacity affect the dispatch solution, operational costs, and CO2 emissions. We also compare the results of two methods for solving the stochastic optimization problem, namely the probabilistically robust method and analytical reformulation assuming Gaussian distributions. Case studies are conducted on a modified IEEE 9-bus system with renewables, controllable loads, and congestion. We find that different types and levels of uncertainty have significant impacts on dispatch and emissions. More controllable loads and less conservative solution methodologies lead to lower costs and emissions.« less
Operational Impacts of Operating Reserve Demand Curves on Production Cost and Reliability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krad, Ibrahim; Ibanez, Eduardo; Ela, Erik
The electric power industry landscape is continually evolving. As emerging technologies such as wind, solar, electric vehicles, and energy storage systems become more cost-effective and present in the system, traditional power system operating strategies will need to be reevaluated. The presence of wind and solar generation (commonly referred to as variable generation) may result in an increase in the variability and uncertainty of the net load profile. One mechanism to mitigate this is to schedule and dispatch additional operating reserves. These operating reserves aim to ensure that there is enough capacity online in the system to account for the increasedmore » variability and uncertainty occurring at finer temporal resolutions. A new operating reserve strategy, referred to as flexibility reserve, has been introduced in some regions. A similar implementation is explored in this paper, and its implications on power system operations are analyzed.« less
Operational Impacts of Operating Reserve Demand Curves on Production Cost and Reliability: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Krad, Ibrahim; Ibanez, Eduardo; Ela, Erik
The electric power industry landscape is continually evolving. As emerging technologies such as wind, solar, electric vehicles, and energy storage systems become more cost-effective and present in the system, traditional power system operating strategies will need to be reevaluated. The presence of wind and solar generation (commonly referred to as variable generation) may result in an increase in the variability and uncertainty of the net load profile. One mechanism to mitigate this is to schedule and dispatch additional operating reserves. These operating reserves aim to ensure that there is enough capacity online in the system to account for the increasedmore » variability and uncertainty occurring at finer temporal resolutions. A new operating reserve strategy, referred to as flexibility reserve, has been introduced in some regions. A similar implementation is explored in this paper, and its implications on power system operations are analyzed.« less
NASA Astrophysics Data System (ADS)
Prada, Jose Fernando
Keeping a contingency reserve in power systems is necessary to preserve the security of real-time operations. This work studies two different approaches to the optimal allocation of energy and reserves in the day-ahead generation scheduling process. Part I presents a stochastic security-constrained unit commitment model to co-optimize energy and the locational reserves required to respond to a set of uncertain generation contingencies, using a novel state-based formulation. The model is applied in an offer-based electricity market to allocate contingency reserves throughout the power grid, in order to comply with the N-1 security criterion under transmission congestion. The objective is to minimize expected dispatch and reserve costs, together with post contingency corrective redispatch costs, modeling the probability of generation failure and associated post contingency states. The characteristics of the scheduling problem are exploited to formulate a computationally efficient method, consistent with established operational practices. We simulated the distribution of locational contingency reserves on the IEEE RTS96 system and compared the results with the conventional deterministic method. We found that assigning locational spinning reserves can guarantee an N-1 secure dispatch accounting for transmission congestion at a reasonable extra cost. The simulations also showed little value of allocating downward reserves but sizable operating savings from co-optimizing locational nonspinning reserves. Overall, the results indicate the computational tractability of the proposed method. Part II presents a distributed generation scheduling model to optimally allocate energy and spinning reserves among competing generators in a day-ahead market. The model is based on the coordination between individual generators and a market entity. The proposed method uses forecasting, augmented pricing and locational signals to induce efficient commitment of generators based on firm posted prices. It is price-based but does not rely on multiple iterations, minimizes information exchange and simplifies the market clearing process. Simulations of the distributed method performed on a six-bus test system showed that, using an appropriate set of prices, it is possible to emulate the results of a conventional centralized solution, without need of providing make-whole payments to generators. Likewise, they showed that the distributed method can accommodate transactions with different products and complex security constraints.
76 FR 29335 - Qualification, Service, and Use of Crewmembers and Aircraft Dispatchers
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-20
...On January 12, 2009, the FAA published a notice of proposed rulemaking on qualification, service, and use of crewmembers and aircraft dispatchers. Because of the complexity of the issues and the concerns raised by commenters, the FAA is issuing this supplemental notice of proposed rulemaking. The FAA proposes to amend the regulations for crewmember and aircraft dispatcher training programs in domestic, flag, and supplemental operations. The proposed regulations enhance traditional training programs by requiring the use of flight simulation training devices for flightcrew members and including additional training and evaluation requirements for all crewmembers and aircraft dispatchers in areas that are critical to safety. The proposal also reorganizes and revises the qualification, training, and evaluation requirements. The proposed changes are intended to contribute significantly to reducing aviation accidents.
Interior detail of dispatch boards in main hall, facing west ...
Interior detail of dispatch boards in main hall, facing west - International Longshoremen's & Warehousemen's Union Hall, Naval Civil Engineering Laboratory, Port Hueneme Road, Port Hueneme, Ventura County, CA
DOE Office of Scientific and Technical Information (OSTI.GOV)
Firestone, Ryan; Marnay, Chris
The on-site generation of electricity can offer buildingowners and occupiers financial benefits as well as social benefits suchas reduced grid congestion, improved energy efficiency, and reducedgreenhouse gas emissions. Combined heat and power (CHP), or cogeneration,systems make use of the waste heat from the generator for site heatingneeds. Real-time optimal dispatch of CHP systems is difficult todetermine because of complicated electricity tariffs and uncertainty inCHP equipment availability, energy prices, and system loads. Typically,CHP systems use simple heuristic control strategies. This paper describesa method of determining optimal control in real-time and applies it to alight industrial site in San Diego, California, tomore » examine: 1) the addedbenefit of optimal over heuristic controls, 2) the price elasticity ofthe system, and 3) the site-attributable greenhouse gas emissions, allunder three different tariff structures. Results suggest that heuristiccontrols are adequate under the current tariff structure and relativelyhigh electricity prices, capturing 97 percent of the value of thedistributed generation system. Even more value could be captured bysimply not running the CHP system during times of unusually high naturalgas prices. Under hypothetical real-time pricing of electricity,heuristic controls would capture only 70 percent of the value ofdistributed generation.« less
Selection of battery technology to support grid-integrated renewable electricity
NASA Astrophysics Data System (ADS)
Leadbetter, Jason; Swan, Lukas G.
2012-10-01
Operation of the electricity grid has traditionally been done using slow responding base and intermediate load generators with fast responding peak load generators to capture the chaotic behavior of end-use demands. Many modern electricity grids are implementing intermittent non-dispatchable renewable energy resources. As a result, the existing support services are becoming inadequate and technological innovation in grid support services are necessary. Support services fall into short (seconds to minutes), medium (minutes to hours), and long duration (several hours) categories. Energy storage offers a method of providing these services and can enable increased penetration rates of renewable energy generators. Many energy storage technologies exist. Of these, batteries span a significant range of required storage capacity and power output. By assessing the energy to power ratio of electricity grid services, suitable battery technologies were selected. These include lead-acid, lithium-ion, sodium-sulfur, and vanadium-redox. Findings show the variety of grid services require different battery technologies and batteries are capable of meeting the short, medium, and long duration categories. A brief review of each battery technology and its present state of development, commercial implementation, and research frontiers is presented to support these classifications.
Thermal Analysis of of Near-Isothermal Compressed Gas Energy Storage System
Odukomaiya, Adewale; Abu-Heiba, Ahmad; Gluesenkamp, Kyle R.; ...
2016-01-01
In this paper, alternative system configurations for a novel Ground-Level Integrated Diverse Energy Storage (GLIDES) system, which can store energy via input of electricity and heat and deliver dispatchable electricity, is presented. The proposed system is low-cost and hybridizes compressed air and pumped hydro storage approaches that will allow for the off-peak storage of intermittent renewable energy for use during peak times. This study reveals that implementing direct-contact low grade heat exchange via sprayed falling droplets to cool the gas during charging (compression) and warm the gas during discharging (expansion) can be achieved through a secondary recirculating loop of liquid.more » This study shows that if the recirculating liquid loop is pre-conditioned with waste-heat prior to spraying during gas expansion and considering all the round trip conversion losses from standard 120 V 60 HZ electricity input and output with utilization of low grade heat at 90 C the alternative system design leads to a 16% boost in round trip efficiency of the electricity storage to elec = 82% with an energy density of ED = 3.59 MJ/m3.« less
Refined genetic algorithm -- Economic dispatch example
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sheble, G.B.; Brittig, K.
1995-02-01
A genetic-based algorithm is used to solve an economic dispatch (ED) problem. The algorithm utilizes payoff information of perspective solutions to evaluate optimality. Thus, the constraints of classical LaGrangian techniques on unit curves are eliminated. Using an economic dispatch problem as a basis for comparison, several different techniques which enhance program efficiency and accuracy, such as mutation prediction, elitism, interval approximation and penalty factors, are explored. Two unique genetic algorithms are also compared. The results are verified for a sample problem using a classical technique.
Flair-fleet location and information reporting
NASA Technical Reports Server (NTRS)
Norman, E. R.; Dunlap, M. E.
1974-01-01
The FLAIR system, as now produced, automatically updates each vehicle's location and corresponding officer's status once each two seconds and presents this information to police dispatchers in the command and control center. The position of all vehicles available for assignment is displayed on a color video map at each dispatcher's console to an accuracy of 50 feet. This gives the dispatcher a continuous picture of the deployment of the total available force and thus complete command and control of all police under his responsibility.
NASA Astrophysics Data System (ADS)
Yuanyuan, Xu; Zhengmao, Zhang; Xiang, Fang; Yuanshuai, Xu; Xinxin, Song
2018-03-01
The combination of theory and practice is a difficult problem on dispatcher training. Through a typical example of case, this paper provides an effective case teaching method for dispatcher training, and combines the theoretical discussion of the rule of experience with cases and achieves vividness. It helps students to understand and catch the key points of the theory, and improve their practical skills.
Intelligent power consumption with two-way shift able feature and its implementation
NASA Astrophysics Data System (ADS)
Xu, Jing; Liu, Youwei
2017-10-01
This paper proposes an intelligent power consumption system with two-way shift able feature and its implementation. Based on power consumption information of standby load and load in working state, a dispatching system decomposes load regulation demand top-down to smart appliances and makes them response orderly as required. It designs a code-based representation method for power consumption information and takes account of standby load, which lays the information foundation for load increment. It also presents a shift able index, which can be used to comprehensively reflect feature of electrical equipment and users and provides a basis for load priority.
NASA Technical Reports Server (NTRS)
Thomas, R. L.; Richards, T. R.
1977-01-01
The ERDA/NASA 100 kW Mod-0 wind turbine is operating at the NASA Plum Brook Station near Sandusky, Ohio. The operation of the wind turbine has been fully demonstrated and includes start-up, synchronization to the utility network, blade pitch control for control of power and speed, and shut-down. Also, fully automatic operation has been demonstrated by use of a remote control panel, 50 miles from the site, similar to what a utility dispatcher might use. The operation systems and experience with the wind turbine loads, electrical power and aerodynamic performance obtained from testing are described.
Kim, Bongyoung
2015-04-01
South Korea dispatches Korean nationals to partner developing countries as an Official Development Assistance (ODA) project through the Korea International Cooperation Agency (KOICA). In the health sector, KOICA dispatches international cooperation doctors (ICDs), nurses, physical therapists, radiologic technologists, nutritionists, medical laboratory technologists, occupational therapists, and dental hygienists. A total of 216 ICDs were dispatched over 19 times from 1995 until 2013. There were 19 areas of specialties among the ICDs. The most common specialty was internal medicine (61/216, 28.2%), the second most common specialty was general surgery (43/216, 19.9%), followed by oriental medicine (27/216, 12.5%), pediatrics (17/216, 7.9%), orthopedics (16/216, 7.4%), family medicine (16/216, 7.4%), and odontology (14/216, 6.5%). The ICDs have worked in 21 countries. KOICA dispatched the highest number of ICDs to Asia (97/216, 44.9%), followed by Africa (50/216, 23.1%), Latin America (34/216, 15.7%), the commonwealth of independent states (31/216, 14.4%), and Oceania (4/216, 1.9%). Nobody was dispatched to the Middle East. A total of 134 KOICA health professionals were dispatched to Peru from 1996 until October 1, 2014. Of these, 19.4% (26/134) were ICDs, 44.8% (60/216) were nurses, 20.1% (27/134) were physical therapists, 6.7% (9/134) were radiologic technologists, 2.2% (3/134) were nutritionists, and 6.7% (9/134) were medical laboratory. ICDs' specialties comprised internal medicine (13/26, 50%), family medicine (8/26, 30.8%), pediatrics (2/26, 7.7%), otorhinolaryngology (1/26, 3.8%), orthopedics (1/26, 3.8%), and oriental medicine (1/26, 3.8%). Most of the dispatched health professionals worked at institutions that were supported by KOICA. For this reason, the proportion of health professionals who worked at public health centers (PHCs) was the highest (58.2%, 78/134) when classified by workplace type. Other KOICA health professionals worked at hospitals, governmental organizations (GOs), or schools.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Makarov, Yuri V.; Lu, Shuai
2008-07-15
This report presents a methodology developed to study the future impact of wind on BPA power system load following and regulation requirements. The methodology uses historical data and stochastic processes to simulate the load balancing processes in the BPA power system, by mimicking the actual power system operations. Therefore, the results are close to reality, yet the study based on this methodology is convenient to conduct. Compared with the proposed methodology, existing methodologies for doing similar analysis include dispatch model simulation and standard deviation evaluation on load and wind data. Dispatch model simulation is constrained by the design of themore » dispatch program, and standard deviation evaluation is artificial in separating the load following and regulation requirements, both of which usually do not reflect actual operational practice. The methodology used in this study provides not only capacity requirement information, it also analyzes the ramp rate requirements for system load following and regulation processes. The ramp rate data can be used to evaluate generator response/maneuverability requirements, which is another necessary capability of the generation fleet for the smooth integration of wind energy. The study results are presented in an innovative way such that the increased generation capacity or ramp requirements are compared for two different years, across 24 hours a day. Therefore, the impact of different levels of wind energy on generation requirements at different times can be easily visualized.« less
NASA Astrophysics Data System (ADS)
Kennedy, Scott Warren
A steady decline in the cost of wind turbines and increased experience in their successful operation have brought this technology to the forefront of viable alternatives for large-scale power generation. Methodologies for understanding the costs and benefits of large-scale wind power development, however, are currently limited. In this thesis, a new and widely applicable technique for estimating the social benefit of large-scale wind power production is presented. The social benefit is based upon wind power's energy and capacity services and the avoidance of environmental damages. The approach uses probabilistic modeling techniques to account for the stochastic interaction between wind power availability, electricity demand, and conventional generator dispatch. A method for including the spatial smoothing effect of geographically dispersed wind farms is also introduced. The model has been used to analyze potential offshore wind power development to the south of Long Island, NY. If natural gas combined cycle (NGCC) and integrated gasifier combined cycle (IGCC) are the alternative generation sources, wind power exhibits a negative social benefit due to its high capacity cost and the relatively low emissions of these advanced fossil-fuel technologies. Environmental benefits increase significantly if charges for CO2 emissions are included. Results also reveal a diminishing social benefit as wind power penetration increases. The dependence of wind power benefits on natural gas and coal prices is also discussed. In power systems with a high penetration of wind generated electricity, the intermittent availability of wind power may influence hourly spot prices. A price responsive electricity demand model is introduced that shows a small increase in wind power value when consumers react to hourly spot prices. The effectiveness of this mechanism depends heavily on estimates of the own- and cross-price elasticities of aggregate electricity demand. This work makes a valuable contribution by synthesizing information from research in power market economics, power system reliability, and environmental impact assessment, to develop a comprehensive methodology for analyzing wind power in the context of long-term energy planning.
26 CFR 49.4253-5 - Exemption for items otherwise taxed.
Code of Federal Regulations, 2011 CFR
2011-04-01
... otherwise taxed. A dispatch, message, or conversation transmitted by toll telephone, telegraph, or... considered to be one dispatch, message, or conversation, and is subject to only one payment of tax under...
26 CFR 49.4253-5 - Exemption for items otherwise taxed.
Code of Federal Regulations, 2010 CFR
2010-04-01
... otherwise taxed. A dispatch, message, or conversation transmitted by toll telephone, telegraph, or... considered to be one dispatch, message, or conversation, and is subject to only one payment of tax under...
Efficient dispatching in a terminal city network
DOT National Transportation Integrated Search
2001-01-01
This report describes new optimization and simulation tools to address several problems in transportation, specifically driver dispatching and tour formation in full truckload trucking. In this segment of transportation industry, one of the problems ...
Best practices in bus dispatch.
DOT National Transportation Integrated Search
2012-06-01
In 2007, the National Center for Transit Research (NCTR) sponsored a study to examine best practices in : extraboard operator management. In most transit agencies, extraboard manpower is managed by the : dispatch function, but extraboard management i...
Seneca Compressed Air Energy Storage (CAES) Project
DOE Office of Scientific and Technical Information (OSTI.GOV)
None, None
2012-11-30
Compressed Air Energy Storage (CAES) is a hybrid energy storage and generation concept that has many potential benefits especially in a location with increasing percentages of intermittent wind energy generation. The objectives of the NYSEG Seneca CAES Project included: for Phase 1, development of a Front End Engineering Design for a 130MW to 210 MW utility-owned facility including capital costs; project financials based on the engineering design and forecasts of energy market revenues; design of the salt cavern to be used for air storage; draft environmental permit filings; and draft NYISO interconnection filing; for Phase 2, objectives included plant constructionmore » with a target in-service date of mid-2016; and for Phase 3, objectives included commercial demonstration, testing, and two-years of performance reporting. This Final Report is presented now at the end of Phase 1 because NYSEG has concluded that the economics of the project are not favorable for development in the current economic environment in New York State. The proposed site is located in NYSEG’s service territory in the Town of Reading, New York, at the southern end of Seneca Lake, in New York State’s Finger Lakes region. The landowner of the proposed site is Inergy, a company that owns the salt solution mining facility at this property. Inergy would have developed a new air storage cavern facility to be designed for NYSEG specifically for the Seneca CAES project. A large volume, natural gas storage facility owned and operated by Inergy is also located near this site and would have provided a source of high pressure pipeline quality natural gas for use in the CAES plant. The site has an electrical take-away capability of 210 MW via two NYSEG 115 kV circuits located approximately one half mile from the plant site. Cooling tower make-up water would have been supplied from Seneca Lake. NYSEG’s engineering consultant WorleyParsons Group thoroughly evaluated three CAES designs and concluded that any of the designs would perform acceptably. Their general scope of work included development of detailed project construction schedules, capital cost and cash flow estimates for both CAES cycles, and development of detailed operational data, including fuel and compression energy requirements, to support dispatch modeling for the CAES cycles. The Dispatch Modeling Consultant selected for this project was Customized Energy Solutions (CES). Their general scope of work included development of wholesale electric and gas market price forecasts and development of a dispatch model specific to CAES technologies. Parsons Brinkerhoff Energy Storage Services (PBESS) was retained to develop an air storage cavern and well system design for the CAES project. Their general scope of work included development of a cavern design, solution mining plan, and air production well design, cost, and schedule estimates for the project. Detailed Front End Engineering Design (FEED) during Phase 1 of the project determined that CAES plant capital equipment costs were much greater than the $125.6- million originally estimated by EPRI for the project. The initial air storage cavern Design Basis was increased from a single five million cubic foot capacity cavern to three, five million cubic foot caverns with associated air production wells and piping. The result of this change in storage cavern Design Basis increased project capital costs significantly. In addition, the development time required to complete the three cavern system was estimated at approximately six years. This meant that the CAES plant would initially go into service with only one third of the required storage capacity and would not achieve full capability until after approximately five years of commercial operation. The market price forecasting and dispatch modeling completed by CES indicated that the CAES technologies would operate at only 10 to 20% capacity factors and the resulting overall project economics were not favorable for further development. As a result of all of these factors, the Phase 1 FEED developed an installed CAES plant cost estimate of approximately $2,300/KW for the 210MW CAES 1A and 2 cycles. The capital cost for the 136 MW CAES 1 cycle was even higher due to the lower generating capacity of the cycle. Notably, the large equipment could have generated additional capacity (up to 270MW) which would have improved the cost per KW; however, the output was limited by the night time transmission system capability. The research herein, therefore, is particular to the site-specific factors that influenced the design and the current and forecasted generation mix and energy prices in Upstate New York and may not necessarily indicate that CAES plants cannot be economically constructed in other places in New York State or the world.« less
Evaluation of Human Reliability in Selected Activities in the Railway Industry
NASA Astrophysics Data System (ADS)
Sujová, Erika; Čierna, Helena; Molenda, Michał
2016-09-01
The article focuses on evaluation of human reliability in the human - machine system in the railway industry. Based on a survey of a train dispatcher and of selected activities, we have identified risk factors affecting the dispatcher`s work and the evaluated risk level of their influence on the reliability and safety of preformed activities. The research took place at the authors` work place between 2012-2013. A survey method was used. With its help, authors were able to identify selected work activities of train dispatcher's risk factors that affect his/her work and the evaluated seriousness of its influence on the reliability and safety of performed activities. Amongst the most important finding fall expressions of unclear and complicated internal regulations and work processes, a feeling of being overworked, fear for one's safety at small, insufficiently protected stations.
Cluster analyses of association of weather, daily factors and emergent medical conditions.
Malkić, Jasmin; Sarajlić, Nermin; Smrke, Barbara U R; Smrke, Dragica
2013-03-01
The goal of this study was to evaluate associations between the meteorological conditions and the number of emergency cases for five distinctive causes of dispatch groups reported to SOS dispatch centre in Uppsala, Sweden. Center's responsibility include alerting to 17 ambulances in whole Uppsala County, area of 8,209 km2 with around 320,000 inhabitants representing the target patient group. Source of the medical data for this study is the database of dispatch data for the year of 2009, while the metrological data have been provided from Uppsala University Department of Earth Sciences yearly weather report. Medical and meteorological data were summoned into the unified data space where each point represents a day with its weather parameters and dispatch cause group cardinality. DBSCAN data mining algorithm was implemented to five distinctive groups of dispatch causes after the data spaces have gone through the variance adjustment and the principal component analyses. As the result, several point clusters were discovered in each of the examined data spaces indicating the distinctive conditions regarding the weather and daily cardinality of the dispatch cause, as well as the associations between these two. Most interesting finding is that specific type of winter weather formed a cluster only around the days with the high count of breathing difficulties, while one of the summer weather clusters made similar association with the days with low number of cases. Findings were confirmed by confidence level estimation based on signal to noise ratio for the observed data points.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jenkin, Thomas J; Larson, Andrew; Ruth, Mark F
In light of the changing electricity resource mixes across the United States, an important question in electricity modeling is how additions and retirements of generation, including additions in variable renewable energy (VRE) generation could impact markets by changing hourly wholesale energy prices. Instead of using resource-intensive production cost models (PCMs) or building and using simple generator supply curves, this analysis uses a 'top-down' approach based on regression analysis of hourly historical energy and load data to estimate the impact of supply changes on wholesale electricity prices, provided the changes are not so substantial that they fundamentally alter the market andmore » dispatch-order driven behavior of non-retiring units. The rolling supply curve (RSC) method used in this report estimates the shape of the supply curve that fits historical hourly price and load data for given time intervals, such as two-weeks, and then repeats this on a rolling basis through the year. These supply curves can then be modified on an hourly basis to reflect the impact of generation retirements or additions, including VRE and then reapplied to the same load data to estimate the change in hourly electricity price. The choice of duration over which these RSCs are estimated has a significant impact on goodness of fit. For example, in PJM in 2015, moving from fitting one curve per year to 26 rolling two-week supply curves improves the standard error of the regression from 16 dollars/MWh to 6 dollars/MWh and the R-squared of the estimate from 0.48 to 0.76. We illustrate the potential use and value of the RSC method by estimating wholesale price effects under various generator retirement and addition scenarios, and we discuss potential limits of the technique, some of which are inherent. The ability to do this type of analysis is important to a wide range of market participants and other stakeholders, and it may have a role in complementing use of or providing calibrating insights to PCMs.« less
The Economic Potential of Two Nuclear-Renewable Hybrid Energy Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ruth, Mark; Cutler, Dylan; Flores-Espino, Francisco
Tightly coupled nuclear-renewable hybrid energy systems (N-R HESs) are an option that can generate zero-carbon, dispatchable electricity and provide zero-carbon energy for industrial processes at a lower cost than alternatives. N-R HESs are defined as systems that are managed by a single entity and link a nuclear reactor that generates heat, a thermal power cycle for heat to electricity conversion, at least one renewable energy source, and an industrial process that uses thermal and/or electrical energy. This report provides results of an analysis of two N-R HES scenarios. The first is a Texas-synthetic gasoline scenario that includes four subsystems: amore » nuclear reactor, thermal power cycle, wind power plant, and synthetic gasoline production technology. The second is an Arizona-desalination scenario with its four subsystems a nuclear reactor, thermal power cycle, solar photovoltaics, and a desalination plant. The analysis focuses on the economics of the N-R HESs and how they compare to other options, including configurations without all the subsystems in each N-R HES and alternatives where the energy is provided by natural gas.« less
NASA Astrophysics Data System (ADS)
Buscheck, T. A.; Bielicki, J. M.; Randolph, J.; Chen, M.; Hao, Y.; Sun, Y.
2013-12-01
Abstract We present an approach to use CO2 to (1) generate dispatchable renewable power that can quickly respond to grid fluctuations and be cost-competitive with natural gas, (2) stabilize the grid by efficiently storing large quantities of energy, (3) enable seasonal storage of solar thermal energy for grid integration, (4) produce brine for power-plant cooling, all which (5) increase CO2 value, rendering CO2 capture to be commerically viable, while (6) sequestering huge quantities of CO2. These attributes reduce carbon intensity of electric power, and enable cost-competitive, dispatchable power from major sources of renewable energy: wind, solar, and geothermal. Conventional geothermal power systems circulate brine as the working fluid to extract heat, but the parasitic power load for this circulation can consume a large portion of gross power output. Recently, CO2 has been considered as a working fluid because its advantageous properties reduce this parasitic loss. We expand on this idea by using multiple working fluids: brine, CO2, and N2. N2 can be separated from air at lower cost than captured CO2, it is not corrosive, and it will not react with the formation. N2 also can improve the economics of energy production and enable energy storage, while reducing operational risk. Extracting heat from geothermal reservoirs often requires submersible pumps to lift brine, but these pumps consume much of the generated electricity. In contrast, our approach drives fluid circulation by injecting supplemental, compressible fluids (CO2, and N2) with high coefficients of thermal expansion. These fluids augment reservoir pressure, produce artesian flow at the producers, and reduce the parasitic load. Pressure augmentation is improved by the thermosiphon effect that results from injecting cold/dense CO2 and N2. These fluids are heated to reservoir temperature, greatly expand, and increase the artesian flow of brine and supplemental fluid at the producers. Rather than using pumps, the thermosiphon directly converts reservoir thermal energy into mechanical energy for fluid circulation. Because stored pressure drives fluid production, the response time is faster than that of conventional geothermal power, already considered to be dispatchable. For conventional geothermal, the parasitic power load is in phase with gross power output. In contrast, our approach can time-shift much of the parasitic power load, which is dominated by the power required to separate N2 from air and compress it for injection. Because N2 is readily available, it can be injected intermittently. Thus, most of the parasitic power load can be shifted to coincide with minimum power demand or when there is a surplus of renewable power. Such a time-shift also allows net power output to be nearly equal to gross power output during peak demand. Energy storage can be almost 100 percent efficient because it is achieved by shifting the parasitic load, which is more efficient than other methods used to store energy and stabilize the grid. This work was performed under the auspices of the U.S. DOE by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344.
Evaluating the Impacts of Real-Time Pricing on the Cost and Value of Wind Generation
Siohansi, Ramteen
2010-05-01
One of the costs associated with integrating wind generation into a power system is the cost of redispatching the system in real-time due to day-ahead wind resource forecast errors. One possible way of reducing these redispatch costs is to introduce demand response in the form of real-time pricing (RTP), which could allow electricity demand to respond to actual real-time wind resource availability using price signals. A day-ahead unit commitment model with day-ahead wind forecasts and a real-time dispatch model with actual wind resource availability is used to estimate system operations in a high wind penetration scenario. System operations are comparedmore » to a perfect foresight benchmark, in which actual wind resource availability is known day-ahead. The results show that wind integration costs with fixed demands can be high, both due to real-time redispatch costs and lost load. It is demonstrated that introducing RTP can reduce redispatch costs and eliminate loss of load events. Finally, social surplus with wind generation and RTP is compared to a system with neither and the results demonstrate that introducing wind and RTP into a market can result in superadditive surplus gains.« less
NASA Astrophysics Data System (ADS)
Ng, Chris Fook Sheng; Ueda, Kayo; Ono, Masaji; Nitta, Hiroshi; Takami, Akinori
2014-07-01
Despite rising concern on the impact of heat on human health, the risk of high summer temperature on heatstroke-related emergency dispatches is not well understood in Japan. A time-series study was conducted to examine the association between apparent temperature and daily heatstroke-related ambulance dispatches (HSAD) within the Kanto area of Japan. A total of 12,907 HSAD occurring from 2000 to 2009 in five major cities—Saitama, Chiba, Tokyo, Kawasaki, and Yokohama—were analyzed. Generalized additive models and zero-inflated Poisson regressions were used to estimate the effects of daily maximum three-hour apparent temperature (AT) on dispatch frequency from May to September, with adjustment for seasonality, long-term trend, weekends, and public holidays. Linear and non-linear exposure effects were considered. Effects on days when AT first exceeded its summer median were also investigated. City-specific estimates were combined using random effects meta-analyses. Exposure-response relationship was found to be fairly linear. Significant risk increase began from 21 °C with a combined relative risk (RR) of 1.22 (95 % confidence interval, 1.03-1.44), increasing to 1.49 (1.42-1.57) at peak AT. When linear exposure was assumed, combined RR was 1.43 (1.37-1.50) per degree Celsius increment. Overall association was significant the first few times when median AT was initially exceeded in a particular warm season. More than two-thirds of these initial hot days were in June, implying the harmful effect of initial warming as the season changed. Risk increase that began early at the fairly mild perceived temperature implies the need for early precaution.
Ng, Chris Fook Sheng; Ueda, Kayo; Ono, Masaji; Nitta, Hiroshi; Takami, Akinori
2014-07-01
Despite rising concern on the impact of heat on human health, the risk of high summer temperature on heatstroke-related emergency dispatches is not well understood in Japan. A time-series study was conducted to examine the association between apparent temperature and daily heatstroke-related ambulance dispatches (HSAD) within the Kanto area of Japan. A total of 12,907 HSAD occurring from 2000 to 2009 in five major cities-Saitama, Chiba, Tokyo, Kawasaki, and Yokohama-were analyzed. Generalized additive models and zero-inflated Poisson regressions were used to estimate the effects of daily maximum three-hour apparent temperature (AT) on dispatch frequency from May to September, with adjustment for seasonality, long-term trend, weekends, and public holidays. Linear and non-linear exposure effects were considered. Effects on days when AT first exceeded its summer median were also investigated. City-specific estimates were combined using random effects meta-analyses. Exposure-response relationship was found to be fairly linear. Significant risk increase began from 21 °C with a combined relative risk (RR) of 1.22 (95% confidence interval, 1.03-1.44), increasing to 1.49 (1.42-1.57) at peak AT. When linear exposure was assumed, combined RR was 1.43 (1.37-1.50) per degree Celsius increment. Overall association was significant the first few times when median AT was initially exceeded in a particular warm season. More than two-thirds of these initial hot days were in June, implying the harmful effect of initial warming as the season changed. Risk increase that began early at the fairly mild perceived temperature implies the need for early precaution.
Best practices in bus dispatch [summary].
DOT National Transportation Integrated Search
2012-01-01
In 2007, the National Center for Transit Research : sponsored a study of best practices in extraboard : operator management, finding that in most transit : agencies, extraboard manpower is managed by : dispatchers as one of their many functions. This...
Wind Power Ramping Product for Increasing Power System Flexibility
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cui, Mingjian; Zhang, Jie; Wu, Hongyu
With increasing penetrations of wind power, system operators are concerned about a potential lack of system flexibility and ramping capacity in real-time dispatch stages. In this paper, a modified dispatch formulation is proposed considering the wind power ramping product (WPRP). A swinging door algorithm (SDA) and dynamic programming are combined and used to detect WPRPs in the next scheduling periods. The detected WPRPs are included in the unit commitment (UC) formulation considering ramping capacity limits, active power limits, and flexible ramping requirements. The modified formulation is solved by mixed integer linear programming. Numerical simulations on a modified PJM 5-bus Systemmore » show the effectiveness of the model considering WPRP, which not only reduces the production cost but also does not affect the generation schedules of thermal units.« less
A study on economic power dispatch grid connected PV power plant in educational institutes
NASA Astrophysics Data System (ADS)
Singh, Kuldip; Kumar, M. Narendra; Mishra, Satyasis
2018-04-01
India has main concerns on environment and escalation of fuel prices with respect to diminution of fossil fuel reserves and the major focus on renewable Energy sources for power generation to fulfill the present and future energy demand. Installation of PV power plants in the Educational Institutions has grown up drastically throughout India. More PV power plant are integrated with load and grid through net metering. Therefore, this paper is an analysis of the 75kWp PV plant at chosen buses, considering the need of minimum demand from the grid. The case study is carried out for different generation level throughout the day and year w.r.t load and climate changes, load sharing on grid. The economic dispatch model developed for PV plant integrated with Grid.
Nguyen, Su; Zhang, Mengjie; Tan, Kay Chen
2017-09-01
Automated design of dispatching rules for production systems has been an interesting research topic over the last several years. Machine learning, especially genetic programming (GP), has been a powerful approach to dealing with this design problem. However, intensive computational requirements, accuracy and interpretability are still its limitations. This paper aims at developing a new surrogate assisted GP to help improving the quality of the evolved rules without significant computational costs. The experiments have verified the effectiveness and efficiency of the proposed algorithms as compared to those in the literature. Furthermore, new simplification and visualisation approaches have also been developed to improve the interpretability of the evolved rules. These approaches have shown great potentials and proved to be a critical part of the automated design system.
A review on economic emission dispatch problems using quantum computational intelligence
NASA Astrophysics Data System (ADS)
Mahdi, Fahad Parvez; Vasant, Pandian; Kallimani, Vish; Abdullah-Al-Wadud, M.
2016-11-01
Economic emission dispatch (EED) problems are one of the most crucial problems in power systems. Growing energy demand, limitation of natural resources and global warming make this topic into the center of discussion and research. This paper reviews the use of Quantum Computational Intelligence (QCI) in solving Economic Emission Dispatch problems. QCI techniques like Quantum Genetic Algorithm (QGA) and Quantum Particle Swarm Optimization (QPSO) algorithm are discussed here. This paper will encourage the researcher to use more QCI based algorithm to get better optimal result for solving EED problems.
Zohar, Dov; Huang, Yueng-hsiang; Lee, Jin; Robertson, Michelle
2014-01-01
The study was designed to test the effect of safety climate on safety behavior among lone employees whose work environment promotes individual rather than consensual or shared climate perceptions. The paper presents a mediation path model linking psychological (individual-level) safety climate antecedents and consequences as predictors of driving safety of long-haul truck drivers. Climate antecedents included dispatcher (distant) leadership and driver work ownership, two contextual attributes of lone work, whereas its proximal consequence included driving safety. Using a prospective design, safety outcomes, consisting of hard-braking frequency (i.e. traffic near-miss events) were collected six months after survey completion, using GPS-based truck deceleration data. Results supported the hypothesized model, indicating that distant leadership style and work ownership promote psychological safety climate perceptions, with subsequent prediction of hard-braking events mediated by driving safety. Theoretical and practical implications for studying safety climate among lone workers in general and professional drivers in particular are discussed. Copyright © 2013 Elsevier Ltd. All rights reserved.
Evaluation of a Dispatcher's Route Optimization Decision Aid to Avoid Aviation Weather Hazards
NASA Technical Reports Server (NTRS)
Dorneich, Michael C.; Olofinboba, Olu; Pratt, Steve; Osborne, Dannielle; Feyereisen, Thea; Latorella, Kara
2003-01-01
This document describes the results and analysis of the formal evaluation plan for the Honeywell software tool developed under the NASA AWIN (Aviation Weather Information) 'Weather Avoidance using Route Optimization as a Decision Aid' project. The software tool aims to provide airline dispatchers with a decision aid for selecting optimal routes that avoid weather and other hazards. This evaluation compares and contrasts route selection performance with the AWIN tool to that of subjects using a more traditional dispatcher environment. The evaluation assesses gains in safety, in fuel efficiency of planned routes, and in time efficiency in the pre-flight dispatch process through the use of the AWIN decision aid. In addition, we are interested in how this AWIN tool affects constructs that can be related to performance. The construct of Situation Awareness (SA), workload, trust in an information system, and operator acceptance are assessed using established scales, where these exist, as well as through the evaluation of questionnaire responses and subject comments. The intention of the experiment is to set up a simulated operations area for the dispatchers to work in. They will be given scenarios in which they are presented with stored company routes for a particular city-pair and aircraft type. A diverse set of external weather information sources is represented by a stand-alone display (MOCK), containing the actual historical weather data typically used by dispatchers. There is also the possibility of presenting selected weather data on the route visualization tool. The company routes have not been modified to avoid the weather except in the case of one additional route generated by the Honeywell prototype flight planning system. The dispatcher will be required to choose the most appropriate and efficient flight plan route in the displayed weather conditions. The route may be modified manually or may be chosen from those automatically displayed.
Wind power application research on the fusion of the determination and ensemble prediction
NASA Astrophysics Data System (ADS)
Lan, Shi; Lina, Xu; Yuzhu, Hao
2017-07-01
The fused product of wind speed for the wind farm is designed through the use of wind speed products of ensemble prediction from the European Centre for Medium-Range Weather Forecasts (ECMWF) and professional numerical model products on wind power based on Mesoscale Model5 (MM5) and Beijing Rapid Update Cycle (BJ-RUC), which are suitable for short-term wind power forecasting and electric dispatch. The single-valued forecast is formed by calculating the different ensemble statistics of the Bayesian probabilistic forecasting representing the uncertainty of ECMWF ensemble prediction. Using autoregressive integrated moving average (ARIMA) model to improve the time resolution of the single-valued forecast, and based on the Bayesian model averaging (BMA) and the deterministic numerical model prediction, the optimal wind speed forecasting curve and the confidence interval are provided. The result shows that the fusion forecast has made obvious improvement to the accuracy relative to the existing numerical forecasting products. Compared with the 0-24 h existing deterministic forecast in the validation period, the mean absolute error (MAE) is decreased by 24.3 % and the correlation coefficient (R) is increased by 12.5 %. In comparison with the ECMWF ensemble forecast, the MAE is reduced by 11.7 %, and R is increased 14.5 %. Additionally, MAE did not increase with the prolongation of the forecast ahead.
Managing Sustainable Demand-side Infrastructure for Power System Ancillary Services
NASA Astrophysics Data System (ADS)
Parkinson, Simon Christopher
Widespread access to renewable electricity is seen as a viable method to mitigate carbon emissions, although problematic are the issues associated with the integration of the generation systems within current power system configurations. Wind power plants are the primary large-scale renewable generation technology applied globally, but display considerable short-term supply variability that is difficult to predict. Power systems are currently not designed to operate under these conditions, and results in the need to increase operating reserve in order to guarantee stability. Often, operating conventional generation as reserve is both technically and economically inefficient, which can overshadow positive benefits associated with renewable energy exploitation. The purpose of this thesis is to introduce and assess an alternative method of enhancing power system operations through the control of electric loads. In particular, this thesis focuses on managing highly-distributed sustainable demand-side infrastructure, in the form of heat pumps, electric vehicles, and electrolyzers, as dispatchable short-term energy balancing resources. The main contribution of the thesis is an optimal control strategy capable of simultaneously balancing grid- and demand-side objectives. The viability of the load control strategy is assessed through model-based simulations that explicitly track end-use functionality of responsive devices within a power systems analysis typically implemented to observe the effects of integrated wind energy systems. Results indicate that there is great potential for the proposed method to displace the need for increased reserve capacity in systems considering a high penetration of wind energy, thereby allowing conventional generation to operate more efficiently and avoid the need for possible capacity expansions.
Airline Transport Pilot, Aircraft Dispatcher, and Flight Navigator Knowledge Test Guide
DOT National Transportation Integrated Search
1995-01-01
The Flight Standards Service of the Federal Aviation Administration (FAA) has developed this guide to help applicants meet the knowledge requirements for airline transport pilot, aircraft dispatcher, and flight navigator certification. This guide con...
Aircraft Dispatcher - Practical Test Standards
DOT National Transportation Integrated Search
1995-06-01
The Flight Standards Service of the FAA has developed this practical : test book as a standard to be used by FAA inspectors and designated : examiners when conducting the aircraft dispatcher practical test. : Instructors are expected to use this book...
NASA Technical Reports Server (NTRS)
Smith, Philip J.; Mccoy, C. Elaine; Layton, Charles; Orasanu, Judith; Chappel, Sherry; Palmer, EV; Corker, Kevin
1993-01-01
In a previous report, an empirical study of 30 pilots using the Flight Planning Testbed was reported. An identical experiment using the Flight Planning Testbed (FPT), except that 27 airline dispatchers were studied, is described. Five general questions were addressed in this study: (1) under what circumstances do the introduction of computer-generated suggestions (flight plans) influence the planning behavior of dispatchers (either in a beneficial or adverse manner); (2) what is the nature of such influences (i.e., how are the person's cognitive processes changed); (3) how beneficial are the general design concepts underlying FPT (use of a graphical interface, embedding graphics in a spreadsheet, etc.); (4) how effective are the specific implementation decisions made in realizing these general design concepts; and (5) how effectively do dispatchers evaluate situations requiring replanning, and how effectively do they identify appropriate solutions to these situations.
Augmented Lagrange Hopfield network for solving economic dispatch problem in competitive environment
NASA Astrophysics Data System (ADS)
Vo, Dieu Ngoc; Ongsakul, Weerakorn; Nguyen, Khai Phuc
2012-11-01
This paper proposes an augmented Lagrange Hopfield network (ALHN) for solving economic dispatch (ED) problem in the competitive environment. The proposed ALHN is a continuous Hopfield network with its energy function based on augmented Lagrange function for efficiently dealing with constrained optimization problems. The ALHN method can overcome the drawbacks of the conventional Hopfield network such as local optimum, long computational time, and linear constraints. The proposed method is used for solving the ED problem with two revenue models of revenue based on payment for power delivered and payment for reserve allocated. The proposed ALHN has been tested on two systems of 3 units and 10 units for the two considered revenue models. The obtained results from the proposed methods are compared to those from differential evolution (DE) and particle swarm optimization (PSO) methods. The result comparison has indicated that the proposed method is very efficient for solving the problem. Therefore, the proposed ALHN could be a favorable tool for ED problem in the competitive environment.
Bassil, Kate L; Cole, Donald C; Moineddin, Rahim; Gournis, Effie; Schwartz, Brian; Craig, Alan M; Lou, W Y Wendy; Rea, Elizabeth
2008-01-01
The adverse effects of hot weather on public health are of increasing concern. A surveillance system using 911 medical dispatch data for the detection of heat-related illness (HRI) could provide new information on the impact of excessive heat on the population. This paper describes how we identified medical dispatch call codes, called "determinants", that could represent HRI events. Approximately 500 medical dispatch determinants were reviewed in focus groups composed of Emergency Medical Services (EMS) paramedics, dispatchers, physicians, and public health epidemiologists. Each group was asked to select those determinants that might adequately represent HRI. Selections were then assessed empirically using correlations with daily mean temperature over the study period (June 1-August 31,2005). The focus groups identified 12 determinant groupings and ranked them according to specificity for HRI. Of these, "Heat/cold exposure" was deemed the most specific. The call determinant groupings with the clearest positive associations with daily mean temperature empirically were "Heat/cold exposure" (Spearman's correlation coefficient (SCC) 0.71, p < 0.0001) and "Unknown problem (man down)" (SCC 0.21, p = 0.04). Within each grouping, the determinant "Unknown status (3rd party caller)" showed significant associations, SCC = 0.34 (p = 0.001) and SCC = 0.22 (p = 0.03) respectively. Clinically-informed expertise and empirical evidence both contributed to identification of a group of 911 medical dispatch call determinants that plausibly represent HRI events. Once evaluated prospectively, these may be used in public health surveillance to better understand environmental health impacts on human populations and inform targeted public health interventions.
Alternatives to Traditional EMS Dispatch and Transport: A Scoping Review of Reported Outcomes.
Jensen, Jan L; Carter, Alix J E; Rose, Jennifer; Visintini, Sarah; Bourdon, Emmanuelle; Brown, Ryan; McVey, Jennifer; Travers, Andrew H
2015-09-01
Emergency medical services (EMS) programs, which provide an alternative to traditional EMS dispatch or transport to the emergency department (ED), are becoming widely implemented. This scoping review identified and catalogued all outcomes used to measure such alternative EMS programs. Data Source Broad systematized bibliographic and grey literature searches were conducted. Study Selection Inclusion criteria were 911 callers/EMS patients, reported on alternatives to traditional EMS dispatch OR traditional EMS transport to the ED, and reported an outcome measure. Data Extraction The reports were categorized as either alternative to dispatch or to EMS transport, and outcome measures were categorized and described. Data Synthesis The bibliographic search retrieved 13,215 records, of which 34 articles met the inclusion criteria, with an additional 10 added from reference list hand-searching (n=44 included). In the grey literature search, 31 websites were identified, from which four met criteria and were retrieved (n=4 included). Fifteen reports (16 studies) described alternatives to EMS dispatch, and 33 reports described alternatives to EMS transport. The most common outcomes reported in the alternatives to EMS dispatch reports were service utilization and decision accuracy. Twenty-four different specific outcomes were reported. The most common outcomes reported in the alternatives to EMS transport reports were service utilization and safety, and 50 different specific outcomes were reported. Numerous outcome measures were identified in reports of alternative EMS programs, which were catalogued and described. Researchers and program leaders should achieve consensus on uniform outcome measures, to allow benchmarking and improve comparison across programs.
Riou, Marine; Ball, Stephen; Williams, Teresa A; Whiteside, Austin; O’Halloran, Kay L; Bray, Janet; Perkins, Gavin D; Cameron, Peter; Fatovich, Daniel M; Inoue, Madoka; Bailey, Paul; Brink, Deon; Smith, Karen; Della, Phillip; Finn, Judith
2017-01-01
Introduction Emergency telephone calls placed by bystanders are crucial to the recognition of out-of-hospital cardiac arrest (OHCA), fast ambulance dispatch and initiation of early basic life support. Clear and efficient communication between caller and call-taker is essential to this time-critical emergency, yet few studies have investigated the impact that linguistic factors may have on the nature of the interaction and the resulting trajectory of the call. This research aims to provide a better understanding of communication factors impacting on the accuracy and timeliness of ambulance dispatch. Methods and analysis A dataset of OHCA calls and their corresponding metadata will be analysed from an interdisciplinary perspective, combining linguistic analysis and health services research. The calls will be transcribed and coded for linguistic and interactional variables and then used to answer a series of research questions about the recognition of OHCA and the delivery of basic life-support instructions to bystanders. Linguistic analysis of calls will provide a deeper understanding of the interactional dynamics between caller and call-taker which may affect recognition and dispatch for OHCA. Findings from this research will translate into recommendations for modifications of the protocols for ambulance dispatch and provide directions for further research. Ethics and dissemination The study has been approved by the Curtin University Human Research Ethics Committee (HR128/2013) and the St John Ambulance Western Australia Research Advisory Group. Findings will be published in peer-reviewed journals and communicated to key audiences, including ambulance dispatch professionals. PMID:28694349
49 CFR 241.9 - Prohibition against extraterritorial dispatching; exceptions.
Code of Federal Regulations, 2010 CFR
2010-10-01
... emergency situation, a railroad may require or permit one of its dispatchers located outside the United... or by electronic mail. (3) A list of the States that make up the FRA regions and the street and e...
Impact of data link technology on railroad dispatching operations
DOT National Transportation Integrated Search
2004-10-01
This study examined data link communication as an alternative channel to voice radio for railroad dispatchers. The goal was to compare how data link affected performance compared to voice radio only communications on measures related to safety, produ...
SMART operational field test evaluation : dispatchers survey report : final report
DOT National Transportation Integrated Search
1997-06-01
The Suburban Mobility Authority for Regional Transportation (SMART) has installed an automaticscheduling and dispatch system (ASD) in Southeast Michigan in accordance with their plans toimplement ITS as a site for an operational field test. The purpo...
An analysis of the job of railroad train dispatcher.
DOT National Transportation Integrated Search
1974-04-01
This report constitutes a detailed study of the job of railroad train dispatcher, conducted to provide a data base for the derivation of criteria of job knowledge, skills and training consonant with safe operations. Documentation was reviewed; specia...
Treatment of cardiac arrest with rapid defibrillation by police in King County, Washington.
Becker, Linda; Husain, Sofia; Kudenchuk, Peter; Doll, Ann; Rea, Tom; Eisenberg, Mickey
2014-01-01
Improving survival from out-of-hospital cardiac arrest is an ongoing challenge for emergency medical services (EMS). Various strategies for shortening the time from collapse to defibrillation have been used, and one is to equip police officers with defibrillators. Objective. We evaluated the programmatic implementation of police defibrillation to determine if such a program could improve the process of care in a high-functioning and mature EMS system. We conducted a prospective observational study of implementation of a police defibrillation in two police departments in King County, Washington, from March 1, 2010 to March 31, 2012. The program was designed to dispatch police specifically to cases with a high suspicion of cardiac arrest, defined as a patient who was unconscious and not breathing normally. We included all nontraumatic out-of-hospital cardiac arrest events that occurred prior to EMS arrival and within the city limits of the two cities. We collected both EMS and police dispatch reports to document times of call receipt, dispatch, and arrival of both agencies. We obtained rhythm recordings when the automated external defibrillators (AEDs) were used by the police. Descriptive statistics were used to measure frequency of police dispatch and to compare times to treatment between patients with a police response and those without. During the study period there were 231 cases of cardiac arrest that occurred prior to EMS arrival eligible for police response in the study communities. Police were dispatched to 124 (54%) of these cases. Of the 124, the police arrived before EMS 37 times, or 16% of the 231 cases. Police performed CPR in 29 of these cases and applied the AED in 21 of them. Of the 21 cases in which the AED was applied for cardiac arrest, a shock was delivered on first analysis for 6 patients. Although the response interval between dispatch to scene arrival was similar for EMS and police (4.5 minutes versus 4.6 minutes respectively, p = 0.08), police were dispatched considerably slower than EMS (1.8 minutes versus 0.6 minutes, p < 0.001). In the current programmatic implementation, police had a measurable but limited involvement in resuscitation. Efforts to address dispatch challenges may improve police involvement.
DOT National Transportation Integrated Search
2003-10-01
The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : WSDOT deployment". This document defines the objective, approach,...
A preliminary examination of railroad dispatcher workload, stress, and fatigue
DOT National Transportation Integrated Search
2001-05-01
This report presents the methods, findings and recommendations from a field study that examined the sources and levels of railroad dispatcher workload, stress, and fatigue. The study was initiated in response to concerns raised by two Federal Railroa...
DOT National Transportation Integrated Search
2006-05-01
This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch - Traffic Management Center Integration Field Operations Test in the State of Washington. The document discusses evaluation findings in the foll...
DOT National Transportation Integrated Search
1998-10-11
This paper describes a preliminary cognitive task analysis (CTA) that is being conducted to examine how experienced train dispatchers manage and schedule trains. The CTA uses ethnographic field observations and structured interview techniques. The ob...
Innovative telecommunications for law enforcement
NASA Technical Reports Server (NTRS)
Sohn, R. L.
1976-01-01
The operation of computer-aided dispatch, mobile digital communications, and automatic vehicle location systems used in law enforcement is discussed, and characteristics of systems used by different agencies are compared. With reference to computer-aided dispatch systems, the data base components, dispatcher work load, extent of usage, and design trends are surveyed. The capabilities, levels of communication, and traffic load of mobile digital communications systems are examined. Different automatic vehicle location systems are distinguished, and two systems are evaluated. Other aspects of the application of innovative technology to operational command, control, and communications systems for law enforcement agencies are described.
An online dispatcher training simulator function for real-time analysis and training
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vadari, S.V.; Montstream, M.J.; Ross, H.B. Jr.
1995-11-01
Today`s power systems have become so complex that it is not easy for the system dispatcher to realistically predict the results of outages. The situation is compounded whenever the power grid is not in its normal configuration due to maintenance switching or equipment failure. The authors feel that the DTS is an excellent tool that can be used to teach the dispatcher how to react under these conditions. In this paper, the authors present an on-line implementation of the DTS which allows the user to initialize the DTS to an EMS disturbance using data that was captured at the timemore » of the disturbance; and place the DTS in a playback mode and go back to specific times in the scenario. The former feature allows the analyst to investigate EMS disturbances and then train the various dispatchers to be able to recognize such disturbances and to recover from them when they occur. The latter feature allows the instructor (with the trainee) to review and re-experience desired portions of the scenario. It is the authors` feeling that these two features will help the EMS operational staff understand their power system better and help their dispatchers in dealing with operational problems associated with the proper running of the system.« less
Clawson, Jeff; Olola, Christopher; Heward, Andy; Patterson, Brett; Scott, Greg
2008-01-01
To determine if Medical Priority Dispatch System's (MPDS's) Protocol 32-Unknown Problem interrogation-based differential dispatch coding distinguishes the acuity of patients as found at the scene by responders, when little (if any) clinical information is known. "Unknown problem" situations (i.e., all cases not fitting into any other chief complaint group) constitute 5-8% of all calls to dispatch centers. From the total patient encounters (n=599,107) in the aggregate data of one year (September 2005 to August 2006), we examined 3,947 (0.7%) encounters initially coded as "unknown problem" by the London Ambulance Service Communications Center for the scene presence of cardiac arrest (CA) and paramedic-determined high-acuity (blue-in [BI]/"lights and siren") findings. Odds ratios (ORs) with 95% confidence intervals (95% CIs) and p-values were used to assess the degree of associations between determinant codes and case outcomes (i.e., CA/BI). Statistically significant association between clinical dispatch determinant codes and case outcomes was observed in the "life status questionable" (LSQ; DELTA-1 [D-1]) and the "standing, sitting, moving, or talking" (BRAVO-1 [B-1]) code pair for the CA outcome (OR [95% CI]: 0.11 [0, 0.63], p=0.005) and for the BI outcome (OR [95% CI]: 0.47 [0.28, 0.77], p=0.003). The LSQ and all three code pairs (i.e., B-1; "community alarm notifications" [B-2]; and "unknown status" [B-3]) also demonstrated significant associations both with the CA outcome (OR [95% CI]: 0.43 [0.23, 0.81], p=0.010) and with the BI outcome (OR [95% CI]: 0.74 [0.56, 0.97], p=0.033). All the determinant code levels yielded significant association between BI and CA cases. This dispatch protocol for unknown problems successfully differentiates dispatch coding of low-acuity and non-CA patients only when specific situational information such as the patient's standing, sitting, moving, or talking can be determined during the interrogation process. Also, emergency medical dispatcher (EMD) reliance on caller-volunteered information to identify predefined critical situations does not appear to add to the protocol's ability to differentiate high-acuity and CA patients. LSQ proved to be a better predictor of both CA and BI outcomes, when compared with the BRAVO-level determinant codes within the "unknown problem" chief complaint. The B-3 (completely unknown) determinant code is a better predictor of severe outcomes than nearly all of the clinically similar BRAVO determinant codes in the entire MPDS protocol. Hence, the B-3 coding should be considered-in terms of its predictability for severe outcome-as falling somewhere between a typical DELTA and a typical BRAVO determinant code.
NASA Astrophysics Data System (ADS)
Wohland, Jan; Witthaut, Dirk
2017-04-01
Electricity systems with a high penetration of renewables are strongly affected by weather patterns. Due to the variability of the climate system, a substantial fraction of energy supply needs to be provided by dispatchable power plants even if the consumption is on average balanced by renewables (e.g. Rodriguez et al. [2014]). In an interconnected system like the European electricity grid, benefits can arise from balancing generation mismatches spatially as long as overproduction in one region coincides with lack of generation in another region. These benefits might change as the climate changes and we thus investigate alterations of correlations between wind timeseries and Backup energy requirements. Our analysis is based on a five member model-ensemble from the EUROCORDEX initiative and we focus on onshore wind energy. We use the highest temporal (3h) and spatial (0.11°) resolution available to capture the intermittent and spatially diverse nature of renewable generation. In view of inter-model spread and other uncertainties, we use the strong climate change scenario rcp8.5 in order to obtain a high signal-to-noise ratio. We argue that rcp8.5 is best suited to reveal interesting interactions between climate change and renewable electricity system despite the fact that is in contradiction to the UNFCCC temperature goals (e.g. Schleussner et al. [2016]). We report spatially inhomogeneous alterations of correlations. In particular, we find increasing correlations between central and northern European states and decreasing correlations at the south-western and south-eastern margins of Europe. This hints to a lowering of balancing potentials within central and northern Europe due to climate change. A possible explanation might be associated to polar amplification and increasing frequencies of blocking events (Coumou [2015]). Moreover, we compute wind energy generation using a single-turbine model and a semi-random deployment procedure as developed in Monforti et al. [2016]. In combination with ENTSO-E load data and validated solar generation timeseries from Renewable Ninja (Pfenninger and Staffell [2016]), we calculate backup energy needs in Europe and analyze the potential of cooperation between countries to lower them. We find increases in European backup energy needs throughout the 21st century which are robust across the 5 climate models considered.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holttinen, Hannele; Kiviluoma, Juha; McCann, John
2015-10-05
This paper presents ways of estimating CO2 reductions of wind power using different methodologies. Estimates based on historical data have more pitfalls in methodology than estimates based on dispatch simulations. Taking into account exchange of electricity with neighboring regions is challenging for all methods. Results for CO2 emission reductions are shown from several countries. Wind power will reduce emissions for about 0.3-0.4 MtCO2/MWh when replacing mainly gas and up to 0.7 MtCO2/MWh when replacing mainly coal powered generation. The paper focuses on CO2 emissions from power system operation phase, but long term impacts are shortly discussed.
A Game Changer: Electrifying Remote Communities by Using Isolated Microgrids
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lu, Xiaonan; Wang, Jianhui
Microgrids, as self-contained entities, are of increasing interest in modern electric grids. Microgrids provide a sustainable solution to aggregate distributed energy resources (DERs) [e.g., photovoltaics (PVs), wind turbines], energy storage, and loads in a localized manner, especially in distribution systems. As a controllable unit, a microgrid can manage and balance the source and load power inside it to ensure stable and reliable operation. Moreover, through coordination with upper-level control systems, it can be dispatched and respond to the control commands issued by the central controller in the distribution system-in other words, a system that is effectively a distribution management systemmore » (DMS).« less
Wind and solar energy curtailment: A review of international experience
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bird, Lori; Lew, Debra; Milligan, Michael
2016-11-01
Greater penetrations of variable renewable generation on some electric grids have resulted in increased levels of curtailment in recent years. Studies of renewable energy grid integration have found that curtailment levels may grow as the penetration of wind and solar energy generation increases. This paper reviews international experience with curtailment of wind and solar energy on bulk power systems in recent years, with a focus on eleven countries in Europe, North America, and Asia. It examines levels of curtailment, the causes of curtailment, curtailment methods and use of market-based dispatch, as well as operational, institutional, and other changes that aremore » being made to reduce renewable energy curtailment.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mather, Barry A; Hodge, Brian S; Cho, Gyu-Jung
Voltage regulation devices have been traditionally installed and utilized to support distribution voltages. Installations of distributed energy resources (DERs) in distribution systems are rapidly increasing, and many of these generation resources have variable and uncertain power output. These generators can significantly change the voltage profile for a feeder; therefore, in the distribution system planning stage of the optimal operation and dispatch of voltage regulation devices, possible high penetrations of DERs should be considered. In this paper, we model the IEEE 34-bus test feeder, including all essential equipment. An optimization method is adopted to determine the optimal siting and operation ofmore » the voltage regulation devices in the presence of distributed solar power generation. Finally, we verify the optimal configuration of the entire system through the optimization and simulation results.« less
DOT National Transportation Integrated Search
2006-07-01
This document provides the final report for the evaluation of the USDOT-sponsored Computer-Aided Dispatch Traffic Management Center Integration Field Operations Test in the State of Utah. The document discusses evaluation findings in the followin...
DOT National Transportation Integrated Search
2004-01-01
The purpose of this document is to expand upon the evaluation components presented in "Computer-aided dispatch--traffic management center field operational test final evaluation plan : state of Utah". This document defines the objective, approach, an...
Understanding how train dispatchers manage and control trains : results of a cognitive task analysis
DOT National Transportation Integrated Search
1999-03-01
This report documents the results of a preliminary Cognitive Task Analysis (CTA) that examined how experienced train dispatchers manage and : schedule trains in today's environment The objective was to understand the cognitive demands placed on train...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M.; Palchak, Joseph D; McBennett, Brendan
The higher-spatial-resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.' The Regional Study validates the relative value of mitigation strategies demonstrated in the National Study - namely, coordinatedmore » operations among states reduce production costs, and reducing coal minimum generation levels reduces RE curtailment. Significantly, the Regional Study also highlights a potential barrier to realizing the value of these mitigation strategies: when locations of RE development are planned independently of state-level transmission, intrastate congestion can result in undesirable levels of RE curtailment. Therefore a key objective of this study is to illustrate to state-level power system planners and operators, in particular, how a higher-resolution model, inclusive of intrastate granularity, can be used as a planning tool for two primary purposes: -To better anticipate, understand, and mitigate system constraints that could affect RE integration; and - To provide a modeling framework that can be used as part of future transmission studies and planning efforts. The Regional Study is not intended to predict precisely how RE will affect state-level operations. There is considerable uncertainty regarding the locations of the RE development, as well as how contract terms can affect access to the inherent physical flexibility of the system. But the scenarios analyzed identify the types of issues that can arise under various RE and transmission expansion pathways. The model developed for this study provides a rigorous framework for future work and can be updated with the characteristics of new capacity as more information on the future power system is known.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin M
The higher-spatial-resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.' The Regional Study validates the relative value of mitigation strategies demonstrated in the National Study - namely, coordinatedmore » operations among states reduce production costs, and reducing coal minimum generation levels reduces RE curtailment. Significantly, the Regional Study also highlights a potential barrier to realizing the value of these mitigation strategies: when locations of RE development are planned independently of state-level transmission, intrastate congestion can result in undesirable levels of RE curtailment. Therefore a key objective of this study is to illustrate to state-level power system planners and operators, in particular, how a higher-resolution model, inclusive of intrastate granularity, can be used as a planning tool for two primary purposes: to better anticipate, understand, and mitigate system constraints that could affect RE integration; and to provide a modeling framework that can be used as part of future transmission studies and planning efforts. The Regional Study is not intended to predict precisely how RE will affect state-level operations. There is considerable uncertainty regarding the locations of the RE development, as well as how contract terms can affect access to the inherent physical flexibility of the system. But the scenarios analyzed identify the types of issues that can arise under various RE and transmission expansion pathways. The model developed for this study provides a rigorous framework for future work and can be updated with the characteristics of new capacity as more information on the future power system is known.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin
The higher-spatial-resolution model of 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. II - Regional Study' (the Regional Study), which better represents the impact of congestion on least-cost scheduling and dispatch, provides a deeper understanding of the relationship among renewable energy (RE) location, transmission, and system flexibility with regard to RE integration, compared to 'Greening the Grid: Pathways to Integrate 175 Gigawatts of Renewable Energy into India's Electric Grid, Vol. I - National Study.' The Regional Study validates the relative value of mitigation strategies demonstrated in the National Study - namely, coordinatedmore » operations among states reduce production costs, and reducing coal minimum generation levels reduces RE curtailment. Significantly, the Regional Study also highlights a potential barrier to realizing the value of these mitigation strategies: when locations of RE development are planned independently of state-level transmission, intrastate congestion can result in undesirable levels of RE curtailment. Therefore a key objective of this study is to illustrate to state-level power system planners and operators, in particular, how a higher-resolution model, inclusive of intrastate granularity, can be used as a planning tool for two primary purposes: -To better anticipate, understand, and mitigate system constraints that could affect RE integration; and - To provide a modeling framework that can be used as part of future transmission studies and planning efforts. The Regional Study is not intended to predict precisely how RE will affect state-level operations. There is considerable uncertainty regarding the locations of the RE development, as well as how contract terms can affect access to the inherent physical flexibility of the system. But the scenarios analyzed identify the types of issues that can arise under various RE and transmission expansion pathways. The model developed for this study provides a rigorous framework for future work and can be updated with the characteristics of new capacity as more information on the future power system is known.« less
Network Interface Specification for the T1 Microprocessor
1994-05-01
features data transfer directly to/from processor registers, hardware dispatch directly to Active Message handlers (along with limited context...Implementation Choices 9 3.1 Overview .................................... 9 3.2 Context ..................................... 10 3.3 Data Transfer...details of the data transfer functional units, interconnect structure, and network operation. Application Layer Communication Model Communication
REopt: A Platform for Energy System Integration and Optimization: Preprint
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simpkins, T.; Cutler, D.; Anderson, K.
2014-08-01
REopt is NREL's energy planning platform offering concurrent, multi-technology integration and optimization capabilities to help clients meet their cost savings and energy performance goals. The REopt platform provides techno-economic decision-support analysis throughout the energy planning process, from agency-level screening and macro planning to project development to energy asset operation. REopt employs an integrated approach to optimizing a site?s energy costs by considering electricity and thermal consumption, resource availability, complex tariff structures including time-of-use, demand and sell-back rates, incentives, net-metering, and interconnection limits. Formulated as a mixed integer linear program, REopt recommends an optimally-sized mix of conventional and renewable energy, andmore » energy storage technologies; estimates the net present value associated with implementing those technologies; and provides the cost-optimal dispatch strategy for operating them at maximum economic efficiency. The REopt platform can be customized to address a variety of energy optimization scenarios including policy, microgrid, and operational energy applications. This paper presents the REopt techno-economic model along with two examples of recently completed analysis projects.« less
Fujie, Keiko; Nakata, Yoshio; Yasuda, Susumu; Mizutani, Taro; Hashimoto, Koichi
2014-03-01
Bystander-initiated cardiopulmonary resuscitation (CPR) has been reported to increase the possibility of survival in patients with out-of-hospital cardiopulmonary arrest (OHCA). We evaluated the effects of CPR instructions by emergency medical dispatchers on the frequency of bystander CPR and outcomes, and whether these effects differed between family and non-family bystanders. We conducted a retrospective cohort study, using Utstein-style records of OHCA taken in a rural area of Japan between January 2004 and December 2009. Of the 559 patients with non-traumatic OHCA witnessed by laypeople, 231 (41.3%) were given bystander CPR. More OHCA patients received resuscitation when the OHCA was witnessed by non-family bystanders than when it was witnessed by family members (61.4% vs. 34.2%). The patients with non-family-witnessed OHCA were more likely to be given conventional CPR (chest compression plus rescue breathing) or defibrillation with an AED than were those with family-witnessed OHCA. Dispatcher instructions significantly increased the provision of bystander CPR regardless of who the witnesses were. Neurologically favorable survival was increased by CPR in non-family-witnessed, but not in family-witnessed, OHCA patients. No difference in survival rate was observed between the cases provided with dispatcher instructions and those not provided with the instructions. Dispatcher instructions increased the frequency of bystander CPR, but did not improve the rate of neurologically favorable survival in patients with witnessed OHCA. Efforts to enhance the frequency and quality of resuscitation, especially by family members, are required for dispatcher-assisted CPR. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Air ambulance tasking: mechanism of injury, telephone interrogation or ambulance crew assessment?
Wilmer, Ian; Chalk, Graham; Davies, Gareth Edward; Weaver, Anne Elizabeth; Lockey, David John
2015-10-01
The identification of serious injury is critical to the tasking of air ambulances. London's Air Ambulance (LAA) is dispatched by a flight paramedic based on mechanism of injury (MOI), paramedical interrogation of caller (INT) or land ambulance crew request (REQ).This study aimed to demonstrate which of the dispatch methods was most effective (in accuracy and time) in identifying patients with serious injury. A retrospective review of 3 years of data (to December 2010) was undertaken. Appropriate dispatch was defined as the requirement for LAA to escort the patient to hospital or for resuscitation on-scene. Inaccurate dispatch was where LAA was cancelled or left the patient in the care of the land ambulance crew. The χ(2) test was used to calculate p values; with significance adjusted to account for multiple testing. There were 2203 helicopter activations analysed: MOI 18.9% (n=417), INT 62.4% (n=1375) and REQ 18.7% (n=411). Appropriate dispatch rates were MOI 58.7% (245/417), INT 69.7% (959/1375) and REQ 72.2% (297/411). INT and REQ were both significantly more accurate than MOI (p<0.0001). There was no significant difference in accuracy between INT and REQ (p=0.36). Combining MOI and INT remotely identified 80.2% of patients, with an overtriage rate of 32.8%. Mean time to dispatch (in minutes) was MOI 4, INT 8 and REQ 21. Telephone interrogation of the caller by a flight paramedic is as accurate as ground ambulance crew requests, and both are significantly better than MOI in identifying serious injury. Overtriage remains an issue with all methods. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.
Birkun, Alexei; Glotov, Maksim; Ndjamen, Herman Franklin; Alaiye, Esther; Adeleke, Temidara; Samarin, Sergey
2018-01-01
BACKGROUND: To assess the effectiveness of the telephone chest-compression-only cardiopulmonary resuscitation (CPR) guided by a pre-recorded instructional audio when compared with dispatcher-assisted resuscitation. METHODS: It was a prospective, blind, randomised controlled study involving 109 medical students without previous CPR training. In a standardized mannequin scenario, after the step of dispatcher-assisted cardiac arrest recognition, the participants performed compression-only resuscitation guided over the telephone by either: (1) the pre-recorded instructional audio (n=57); or (2) verbal dispatcher assistance (n=52). The simulation video records were reviewed to assess the CPR performance using a 13-item checklist. The interval from call reception to the first compression, total number and rate of compressions, total number and duration of pauses after the first compression were also recorded. RESULTS: There were no significant differences between the recording-assisted and dispatcher-assisted groups based on the overall performance score (5.6±2.2 vs. 5.1±1.9, P>0.05) or individual criteria of the CPR performance checklist. The recording-assisted group demonstrated significantly shorter time interval from call receipt to the first compression (86.0±14.3 vs. 91.2±14.2 s, P<0.05), higher compression rate (94.9±26.4 vs. 89.1±32.8 min-1) and number of compressions provided (170.2±48.0 vs. 156.2±60.7). CONCLUSION: When provided by untrained persons in the simulated settings, the compression-only resuscitation guided by the pre-recorded instructional audio is no less efficient than dispatcher-assisted CPR. Future studies are warranted to further assess feasibility of using instructional audio aid as a potential alternative to dispatcher assistance.
Mobile-phone dispatch of laypersons for CPR in out-of-hospital cardiac arrest.
Ringh, Mattias; Rosenqvist, Mårten; Hollenberg, Jacob; Jonsson, Martin; Fredman, David; Nordberg, Per; Järnbert-Pettersson, Hans; Hasselqvist-Ax, Ingela; Riva, Gabriel; Svensson, Leif
2015-06-11
Cardiopulmonary resuscitation (CPR) performed by bystanders is associated with increased survival rates among persons with out-of-hospital cardiac arrest. We investigated whether rates of bystander-initiated CPR could be increased with the use of a mobile-phone positioning system that could instantly locate mobile-phone users and dispatch lay volunteers who were trained in CPR to a patient nearby with out-of-hospital cardiac arrest. We conducted a blinded, randomized, controlled trial in Stockholm from April 2012 through December 2013. A mobile-phone positioning system that was activated when ambulance, fire, and police services were dispatched was used to locate trained volunteers who were within 500 m of patients with out-of-hospital cardiac arrest; volunteers were then dispatched to the patients (the intervention group) or not dispatched to them (the control group). The primary outcome was bystander-initiated CPR before the arrival of ambulance, fire, and police services. A total of 5989 lay volunteers who were trained in CPR were recruited initially, and overall 9828 were recruited during the study. The mobile-phone positioning system was activated in 667 out-of-hospital cardiac arrests: 46% (306 patients) in the intervention group and 54% (361 patients) in the control group. The rate of bystander-initiated CPR was 62% (188 of 305 patients) in the intervention group and 48% (172 of 360 patients) in the control group (absolute difference for intervention vs. control, 14 percentage points; 95% confidence interval, 6 to 21; P<0.001). A mobile-phone positioning system to dispatch lay volunteers who were trained in CPR was associated with significantly increased rates of bystander-initiated CPR among persons with out-of-hospital cardiac arrest. (Funded by the Swedish Heart-Lung Foundation and Stockholm County; ClinicalTrials.gov number, NCT01789554.).
Riou, Marine; Ball, Stephen; Williams, Teresa A; Whiteside, Austin; O'Halloran, Kay L; Bray, Janet; Perkins, Gavin D; Cameron, Peter; Fatovich, Daniel M; Inoue, Madoka; Bailey, Paul; Brink, Deon; Smith, Karen; Della, Phillip; Finn, Judith
2017-07-09
Emergency telephone calls placed by bystanders are crucial to the recognition of out-of-hospital cardiac arrest (OHCA), fast ambulance dispatch and initiation of early basic life support. Clear and efficient communication between caller and call-taker is essential to this time-critical emergency, yet few studies have investigated the impact that linguistic factors may have on the nature of the interaction and the resulting trajectory of the call. This research aims to provide a better understanding of communication factors impacting on the accuracy and timeliness of ambulance dispatch. A dataset of OHCA calls and their corresponding metadata will be analysed from an interdisciplinary perspective, combining linguistic analysis and health services research. The calls will be transcribed and coded for linguistic and interactional variables and then used to answer a series of research questions about the recognition of OHCA and the delivery of basic life-support instructions to bystanders. Linguistic analysis of calls will provide a deeper understanding of the interactional dynamics between caller and call-taker which may affect recognition and dispatch for OHCA. Findings from this research will translate into recommendations for modifications of the protocols for ambulance dispatch and provide directions for further research. The study has been approved by the Curtin University Human Research Ethics Committee (HR128/2013) and the St John Ambulance Western Australia Research Advisory Group. Findings will be published in peer-reviewed journals and communicated to key audiences, including ambulance dispatch professionals. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.
[Modeling and implementation method for the automatic biochemistry analyzer control system].
Wang, Dong; Ge, Wan-cheng; Song, Chun-lin; Wang, Yun-guang
2009-03-01
In this paper the system structure The automatic biochemistry analyzer is a necessary instrument for clinical diagnostics. First of is analyzed. The system problems description and the fundamental principles for dispatch are brought forward. Then this text puts emphasis on the modeling for the automatic biochemistry analyzer control system. The objects model and the communications model are put forward. Finally, the implementation method is designed. It indicates that the system based on the model has good performance.
J. Keith Gilless; Jeremy S. Fried
1998-01-01
A fire behavior module was developed for the California Fire Economics Simulator version 2 (CFES2), a stochastic simulation model of initial attack on wildland fire used by the California Department of Forestry and Fire Protection. Fire rate of spread (ROS) and fire dispatch level (FDL) for simulated fires "occurring" on the same day are determined by making...
14 CFR Special Federal Aviation... - Alternative Communications and Dispatching Procedures
Code of Federal Regulations, 2010 CFR
2010-01-01
... Procedures Federal Special Federal Aviation Regulation 80 Aeronautics and Space FEDERAL AVIATION... No. 80 Special Federal Aviation Regulation 80—Alternative Communications and Dispatching Procedures 1. Applicability. This Special Federal Aviation Regulation applies to each holder of an air carrier or operating...
14 CFR Special Federal Aviation... - Alternative Communications and Dispatching Procedures
Code of Federal Regulations, 2011 CFR
2011-01-01
... Procedures Federal Special Federal Aviation Regulation 80 Aeronautics and Space FEDERAL AVIATION... No. 80 Special Federal Aviation Regulation 80—Alternative Communications and Dispatching Procedures 1. Applicability. This Special Federal Aviation Regulation applies to each holder of an air carrier or operating...
77 FR 64498 - Combined Notice of Filings #1
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-22
... Dispatchable Wind 1, LLC. Description: TEXAS DISPATCHABLE WIND 1, LLC MBR Application to be effective 10/10... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission Combined Notice of Filings 1 Take notice.../12. Docket Numbers: ER12-2619-001. Applicants: Eligo Energy, LLC. Description: Amendment to...
Emergency Medical Dispatch. National Standard Curriculum. Instructor Guide. Trainee Guide.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
This guide contains all instructor materials and requirements for the National Highway Traffic Safety Administration (NHTSA), Emergency Medical Dispatch (EMD) National Standard Curriculum. It includes lesson plans, instructional aids, and tools and supporting information designed to elevate trained and experienced public safety telecommunicators…
Evaluation of transit operations : data applications of Tri-Met's automated bus dispatching system
DOT National Transportation Integrated Search
2001-02-01
This paper presents an analysis of operating performance for Tri-Met, the transit provider for the Portland, Oregon metropolitan area. The analysis draws on data recovered by Tri-Met's automated Bus Dispatching System (BDS) and focuses on two main su...
Highballing with flimsies : working under train orders on the Espee's coast line
DOT National Transportation Integrated Search
1990-01-01
In classic timetable and train-order territory, the study focuses on several dimensions of train : dispatchers' work, viewed through the other end of the telescope, i.e., from the perspective of the : dispatched train crewmembers and others in the fi...
DOT National Transportation Integrated Search
2009-03-01
The ability of transit agencies to staff dispatch effectively and use technology to its full advantage is critical : in responding proactively as service changes occur and in making sound routing decisions. Sound routing : decisions result in improve...
14 CFR 121.535 - Responsibility for operational control: Flag operations.
Code of Federal Regulations, 2013 CFR
2013-01-01
... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...
14 CFR 121.535 - Responsibility for operational control: Flag operations.
Code of Federal Regulations, 2011 CFR
2011-01-01
... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...
14 CFR 121.535 - Responsibility for operational control: Flag operations.
Code of Federal Regulations, 2010 CFR
2010-01-01
... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...
14 CFR 121.535 - Responsibility for operational control: Flag operations.
Code of Federal Regulations, 2012 CFR
2012-01-01
... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...
14 CFR 121.535 - Responsibility for operational control: Flag operations.
Code of Federal Regulations, 2014 CFR
2014-01-01
... dispatcher are jointly responsible for the preflight planning, delay, and dispatch release of a flight in... AND OPERATIONS OPERATING REQUIREMENTS: DOMESTIC, FLAG, AND SUPPLEMENTAL OPERATIONS Flight Operations...— (1) Monitoring the progress of each flight; (2) Issuing necessary instructions and information for...
Transient Control of Synchronous Machine Active and Reactive Power in Micro-grid Power Systems
NASA Astrophysics Data System (ADS)
Weber, Luke G.
There are two main topics associated with this dissertation. The first is to investigate phase-to-neutral fault current magnitude occurring in generators with multiple zero-sequence current sources. The second is to design, model, and tune a linear control system for operating a micro-grid in the event of a separation from the electric power system. In the former case, detailed generator, AC8B excitation system, and four-wire electric power system models are constructed. Where available, manufacturers data is used to validate the generator and exciter models. A gain-delay with frequency droop control is used to model an internal combustion engine and governor. The four wire system is connected through a transformer impedance to an infinite bus. Phase-to-neutral faults are imposed on the system, and fault magnitudes analyzed against three-phase faults to gauge their severity. In the latter case, a balanced three-phase system is assumed. The model structure from the former case - but using data for a different generator - is incorporated with a model for an energy storage device and a net load model to form a micro-grid. The primary control model for the energy storage device has a high level of detail, as does the energy storage device plant model in describing the LC filter and transformer. A gain-delay battery and inverter model is used at the front end. The net load model is intended to be the difference between renewable energy sources and load within a micro-grid system that has separated from the grid. Given the variability of both renewable generation and load, frequency and voltage stability are not guaranteed. This work is an attempt to model components of a proposed micro-grid system at the University of Wisconsin Milwaukee, and design, model, and tune a linear control system for operation in the event of a separation from the electric power system. The control module is responsible for management of frequency and active power, and voltage and reactive power. The scope of this work is to • develop a mathematical model for a salient pole, 2 damper winding synchronous generator with d axis saturation suitable for transient analysis, • develop a mathematical model for a voltage regulator and excitation system using the IEEE AC8B voltage regulator and excitation system template, • develop mathematical models for an energy storage primary control system, LC filter and transformer suitable for transient analysis, • combine the generator and energy storage models in a micro-grid context, • develop mathematical models for electric system components in the stationary abc frame and rotating dq reference frame, • develop a secondary control network for dispatch of micro-grid assets, • establish micro-grid limits of stable operation for step changes in load and power commands based on simulations of model data assuming net load on the micro-grid, and • use generator and electric system models to assess the generator current magnitude during phase-to-ground faults.
NASA Astrophysics Data System (ADS)
Hashemi, Ali Saadatmand; Sattarvand, Javad
2015-03-01
Using simulation modeling, different management systems of the open pit mining equipment including non-dispatching, dispatching and blending solutions have been studied for the Sungun copper mine. Developed model has the capability of considering detailed features of both loading and hauling equipment. Productivity assessment scenarios have been established on the constructed model and the outputs revealed the noteworthy impact of the match factor of the trucks to the loaders on the production rate by over 40%. A dispatching simulation model with the objective function of minimizing truck waiting times have been developed and 7.8% improvement obtained by applying a flexible assignment of the trucks for the loaders compared to the fixed assignment system. Finally ore grade blending control unit has been introduced into the model. Getting the advantages of the newly added module it became possible to monitor the portion of material excavated from different operating benches and control truck dispatching rules for keeping the overall ore grade exactly at desired value.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Not Available
1985-07-01
The report presents the results of a feasibility study for the National Load Dispatch Center and Global Communications System Project in Guatemala. The project consists of a communication system which will provide Institute Nacional de Electrificacion (INDE) operations personnel direct voice access to all major power system facilities. In addition, a modern computer based load dispatch center has been configured on a secure and reliable basis to provide automatic generation control of all major interconnected generating plants within Guatemala.
View southeast of computer controlled energy monitoring system. System replaced ...
View southeast of computer controlled energy monitoring system. System replaced strip chart recorders and other instruments under the direct observation of the load dispatcher. - Thirtieth Street Station, Load Dispatch Center, Thirtieth & Market Streets, Railroad Station, Amtrak (formerly Pennsylvania Railroad Station), Philadelphia, Philadelphia County, PA
Engineering Sedimentary Geothermal Resources for Large-Scale Dispatchable Renewable Electricity
NASA Astrophysics Data System (ADS)
Bielicki, Jeffrey; Buscheck, Thomas; Chen, Mingjie; Sun, Yunwei; Hao, Yue; Saar, Martin; Randolph, Jimmy
2014-05-01
Mitigating climate change requires substantial penetration of renewable energy and economically viable options for CO2 capture and storage (CCS). We present an approach using CO2 and N2 in sedimentary basin geothermal resources that (1) generates baseload and dispatchable power, (2) efficiently stores large amounts of energy, and (3) enables seasonal storage of solar energy, all which (5) increase the value of CO2 and render CCS commercially viable. Unlike the variability of solar and wind resources, geothermal heat is a constant source of renewable energy. Using CO2 as a supplemental geothermal working fluid, in addition to brine, reduces the parasitic load necessary to recirculate fluids. Adding N2 is beneficial because it is cheaper, will not react with materials and subsurface formations, and enables bulk energy storage. The high coefficients of thermal expansion of CO2 and N2 (a) augment reservoir pressure, (b) generate artesian flow at the production wells, and (c) produce self-convecting thermosiphons that directly convert reservoir heat to mechanical energy for fluid recirculation. Stored pressure drives fluid production and responds faster than conventional brine-based geothermal systems. Our design uses concentric rings of horizontal wells to create a hydraulic divide that stores supplemental fluids and pressure. Production and injection wells are controlled to schedule power delivery and time-shift the parasitic power necessary to separate N2 from air and compress it for injection. The parasitic load can be scheduled during minimum power demand or when there is excess electricity from wind or solar. Net power output can nearly equal gross power output during peak demand, and energy storage is almost 100% efficient because it is achieved by the time-shift. Further, per-well production rates can take advantage of the large productivity of horizontal wells, with greater leveraging of well costs, which often constitute a major portion of capital costs for geothermal power systems.
A biometeorology study of climate and heat-related morbidity in Phoenix from 2001 to 2006
NASA Astrophysics Data System (ADS)
Golden, Jay S.; Hartz, Donna; Brazel, Anthony; Luber, George; Phelan, Patrick
2008-07-01
Heat waves kill more people in the United States than hurricanes, tornadoes, earthquakes, and floods combined. Recently, international attention focused on the linkages and impacts of human health vulnerability to urban climate when Western Europe experienced over 30,000 excess deaths during the heat waves of the summer of 2003—surpassing the 1995 heat wave in Chicago, Illinois, that killed 739. While Europe dealt with heat waves, in the United States, Phoenix, Arizona, established a new all-time high minimum temperature for the region on July 15, 2003. The low temperature of 35.5°C (96°F) was recorded, breaking the previous all-time high minimum temperature record of 33.8°C (93°F). While an extensive literature on heat-related mortality exists, greater understanding of influences of heat-related morbidity is required due to climate change and rapid urbanization influences. We undertook an analysis of 6 years (2001 2006) of heat-related dispatches through the Phoenix Fire Department regional dispatch center to examine temporal, climatic and other non-spatial influences contributing to high-heat-related medical dispatch events. The findings identified that there were no significant variations in day-of-week dispatch events. The greatest incidence of heat-related medical dispatches occurred between the times of peak solar irradiance and maximum diurnal temperature, and during times of elevated human comfort indices (combined temperature and relative humidity).
Outcome of patients identified as dead (beyond resuscitation) at the point of the emergency call.
Harvey, L; Woollard, M
2004-05-01
Currently, an emergency ambulance is dispatched to all cardiac arrest victims. This study aimed to determine the outcome of patients with a dispatch code of 09B01 ("obvious death") and considers the appropriateness of dispatching a non-emergency response. Dispatch records, patient report forms, and hospital records were reviewed to determine patient outcome. Within the one year study period 141 emergency calls were coded as 09B01. Records were obtained for 59 of these cases (42%). Ambulance crews diagnosed 54 as beyond resuscitation (91.5%, 95% CI 79.5% to 96.2%). Three received resuscitation attempts (5.1%, 95% CI 1.1% to 14.2%): two were subsequently pronounced dead at scene and one on arrival at hospital. Two patients were not in cardiac arrest (3.4%, 95% CI 0.4% to 11.7%): one was a transiently unconscious assault victim, and one had a hand injury after a road accident. Three patients coded as 09B01 were transported to hospital for treatment other than confirmation of death (5.1%, 95% CI 1.1% to 14.2%). Not all patients coded 09B01 by dispatchers are assessed as "dead beyond resuscitation" by attending ambulance crews. Although poor data recovery and a small sample size limited the study, its findings suggest that it is inappropriate to allocate a non-emergency response to 09B01 (obvious death) calls.
Home Care Providers to the Rescue: A Novel First-Responder Programme
Hansen, Steen M.; Brøndum, Stig; Thomas, Grethe; Rasmussen, Susanne R.; Kvist, Birgitte; Christensen, Anette; Lyng, Charlotte; Lindberg, Jan; Lauritsen, Torsten L. B.; Lippert, Freddy K.; Torp-Pedersen, Christian; Hansen, Poul A.
2015-01-01
Aim To describe the implementation of a novel first-responder programme in which home care providers equipped with automated external defibrillators (AEDs) were dispatched in parallel with existing emergency medical services in the event of a suspected out-of-hospital cardiac arrest (OHCA). Methods We evaluated a one-year prospective study that trained home care providers in performing cardiopulmonary resuscitation (CPR) and using an AED in cases of suspected OHCA. Data were collected from cardiac arrest case files, case files from each provider dispatch and a survey among dispatched providers. The study was conducted in a rural district in Denmark. Results Home care providers were dispatched to 28 of the 60 OHCAs that occurred in the study period. In ten cases the providers arrived before the ambulance service and subsequently performed CPR. AED analysis was executed in three cases and shock was delivered in one case. For 26 of the 28 cases, the cardiac arrest occurred in a private home. Ninety-five per cent of the providers who had been dispatched to a cardiac arrest reported feeling prepared for managing the initial resuscitation, including use of AED. Conclusion Home care providers are suited to act as first-responders in predominantly rural and residential districts. Future follow-up will allow further evaluation of home care provider arrivals and patient survival. PMID:26509532
A biometeorology study of climate and heat-related morbidity in Phoenix from 2001 to 2006.
Golden, Jay S; Hartz, Donna; Brazel, Anthony; Luber, George; Phelan, Patrick
2008-07-01
Heat waves kill more people in the United States than hurricanes, tornadoes, earthquakes, and floods combined. Recently, international attention focused on the linkages and impacts of human health vulnerability to urban climate when Western Europe experienced over 30,000 excess deaths during the heat waves of the summer of 2003-surpassing the 1995 heat wave in Chicago, Illinois, that killed 739. While Europe dealt with heat waves, in the United States, Phoenix, Arizona, established a new all-time high minimum temperature for the region on July 15, 2003. The low temperature of 35.5 degrees C (96 degrees F) was recorded, breaking the previous all-time high minimum temperature record of 33.8 degrees C (93 degrees F). While an extensive literature on heat-related mortality exists, greater understanding of influences of heat-related morbidity is required due to climate change and rapid urbanization influences. We undertook an analysis of 6 years (2001-2006) of heat-related dispatches through the Phoenix Fire Department regional dispatch center to examine temporal, climatic and other non-spatial influences contributing to high-heat-related medical dispatch events. The findings identified that there were no significant variations in day-of-week dispatch events. The greatest incidence of heat-related medical dispatches occurred between the times of peak solar irradiance and maximum diurnal temperature, and during times of elevated human comfort indices (combined temperature and relative humidity).
Market Evolution: Wholesale Electricity Market Design for 21st Century Power Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cochran, Jaquelin; Miller, Mackay; Milligan, Michael
2013-10-01
Demand for affordable, reliable, domestically sourced, and low-carbon electricity is on the rise. This growing demand is driven in part by evolving public policy priorities, especially reducing the health and environmental impacts of electricity service and expanding energy access to under-served customers. Consequently, variable renewable energy resources comprise an increasing share ofelectricity generation globally. At the same time, new opportunities for addressing the variability of renewables are being strengthened through advances in smart grids, communications, and technologies that enable dispatchable demand response and distributed generation to extend to the mass market. A key challenge of merging these opportunities is marketmore » design -- determining how to createincentives and compensate providers justly for attributes and performance that ensure a reliable and secure grid -- in a context that fully realizes the potential of a broad array of sources of flexibility in both the wholesale power and retail markets. This report reviews the suite of wholesale power market designs in use and under consideration to ensure adequacy, security, and flexibilityin a landscape of significant variable renewable energy. It also examines considerations needed to ensure that wholesale market designs are inclusive of emerging technologies, such as demand response, distributed generation, and storage.« less
A three-stage birandom program for unit commitment with wind power uncertainty.
Zhang, Na; Li, Weidong; Liu, Rao; Lv, Quan; Sun, Liang
2014-01-01
The integration of large-scale wind power adds a significant uncertainty to power system planning and operating. The wind forecast error is decreased with the forecast horizon, particularly when it is from one day to several hours ahead. Integrating intraday unit commitment (UC) adjustment process based on updated ultra-short term wind forecast information is one way to improve the dispatching results. A novel three-stage UC decision method, in which the day-ahead UC decisions are determined in the first stage, the intraday UC adjustment decisions of subfast start units are determined in the second stage, and the UC decisions of fast-start units and dispatching decisions are determined in the third stage is presented. Accordingly, a three-stage birandom UC model is presented, in which the intraday hours-ahead forecasted wind power is formulated as a birandom variable, and the intraday UC adjustment event is formulated as a birandom event. The equilibrium chance constraint is employed to ensure the reliability requirement. A birandom simulation based hybrid genetic algorithm is designed to solve the proposed model. Some computational results indicate that the proposed model provides UC decisions with lower expected total costs.
Mostashari, Farzad; Fine, Annie; Das, Debjani; Adams, John; Layton, Marcelle
2003-06-01
In 1998, the New York City Department of Health and the Mayor's Office of Emergency Management began monitoring the volume of ambulance dispatch calls as a surveillance tool for biologic terrorism. We adapted statistical techniques designed to measure excess influenza mortality and applied them to outbreak detection using ambulance dispatch data. Since 1999, we have been performing serial daily regressions to determine the alarm threshold for the current day. In this article, we evaluate this approach by simulating a series of 2,200 daily regressions. In the influenza detection implementation of this model, there were 71 (3.2%) alarms at the 99% level. Of these alarms, 64 (90%) occurred shortly before or during a period of peak influenza in each of six influenza seasons. In the bioterrorism detection implementation of this methodology, after accounting for current influenza activity, there were 24 (1.1%) alarms at the 99% level. Two occurred during a large snowstorm, 1 is unexplained, and 21 occurred shortly before or during a period of peak influenza activity in each of six influenza seasons. Our findings suggest that this surveillance system is sensitive to communitywide respiratory outbreaks with relatively few false alarms. More work needs to be done to evaluate the sensitivity of this approach for detecting nonrespiratory illness and more localized outbreaks.
Training Program for Emergency Medical Technician: Dispatcher. 2--Instructor Lesson Plans.
ERIC Educational Resources Information Center
National Highway Traffic Safety Administration (DOT), Washington, DC.
Intended to assist instructors who wish to conduct a training course for emergency medical technicians (EMTs) serving as dispatchers, this document contains detailed lesson plans organized to structure course presentations. Each lesson plan includes the following elements: unit objectives; suggestions for adapting the lessons to local policies and…